Loading...
2006, 06-13 Mother's Room DrawingWSEC TABLE 6-2 PRESCRIPTIVE REQUIREMENTS°'1 FOR GROUP R OCCUPANCY CLIMATE ZONE 2 Option Glazing Area': oof floor Glazing U-Factor Doors U- Factor Ceiling2 Vaulted Wa1112 Above Grade Wa11? Below Grade Wall? 4 Below Grade Floors Slabs n Grade Vertical Overhead" I. 10% 0.40 0.58 0.20 R-38 R-30 R-21 int7 R-21 R-12 R-30 R-10 11. 15% 0.40 0.58 0.20 R-38 R-30 R-19+ R-58 R-21 R-12 R-30 R-10 III. 17% 0.37 0.58 0.20 R-38 R-30 R-19+ R-58 R-21 R-12 R-30 R-10 IV. 25% Group R-1 Occupancy Only 0.35 0.58 0.20 R-38 / U=0.031 R-30 / U=0.034 R-21 int7 / U=0.054 R-15 R-12 R-30 / U=0.029 R-10 / F=0.54 V. Unlimited Group R-3 Occupancy Only 0.35 0.58 0.20 R-38 R-30 R-21 int7 R-21 R-12 R-30 R-10 VI. Unlimited Group R-1 Occupancy Only 0.32 0.58 0.20 R-38 / U=0.031 R-30 / U=0.034 R-21 int7 / U=0.054 R-15 R-12 R-30 / U=0.029 R-10 / F=0.54 * Reference Case 0. Nominal R-values are for wood frame assemblies only or assemblies built in accordance with Section 601.1. 1. Minimum requirements for each option listed. For example, if a proposed design has a glazing ratio to the conditioned floor area of 13%, it shall comply with all of the requirements of the 15% glazing option (or higher). Proposed designs which cannot meet the specific requirements of a listed option above may calculate compliance by Chapters 4 or 5 of this Code. 2. Requirement applies to all ceilings except single rafter or joist vaulted ceilings. 3. Requirement applicable only to single rafter or joist vaulted ceilings. 4. Below grade walls shall be insulated either on the exterior to a minimum level of R-10, or on the interior to the same level as walls above grade. Exterior insulation installed on below grade walls shall be a water resistant material, manufactured for its intended use, and installed according to the manufacturer's specifications. See Section 602.2. 5. FIoors over crawl spaces or exposed to ambient air conditions. 6. Required slab perimeter insulation shall be a water resistant material, manufactured for its intended use, and installed according to manufacturer's specifications. See Section 602.4. 7. Int. denotes standard framing 16 inches on center with headers insulated with a minimum of R-5 insulation. WSEC Builder's Field Guide 5th Edition COOPERATIVE -EXTENSION WASHINGTON STATE UNIVERSITY 15, ENERGY PROGRAM 1-7 DWELLINGS. THE DWELLING UNIT SHALL DE PROVIDED WITH SMOKE ALARMS LOCATED AS REOUIRED FOR NEW DWELLINGS. [� w Noolos y'tv ?t3N EMERGENCY EGRESS REQUIREMENTS FROM SLEEPING ROOMS 1) NET CLEAR OPENING: 5.7 SOI;ARE FEET GRADE FLOOR OPENING (MAX 44") 5 0 SilW:.RF FEET 2) NET CLEAR OPENING HEIGHT 24 INCHES 3) NET CLEAR OPENING WIDTH 20 INCHES 4) MAX FINISHED SILL HEIGHT 44" AOOVE FLOOR 5) EMERGENCY ESCAPE & RESCUE OPENING SHALL BE OPERATIONAL FROM THE INSIDE OF THE ROOM WITHOUT THE 11SE OF KEYS 0R TOOLS E?V0 2val� 0,1 SMOKE ALARMS SHALL BE INTERCON- NECTED AND HARD WIRED IN SUCH A MANNER THAT THE ACTIVATION OF ONE ALARM WILL ACTIVATE ALL ALARMS. (BEDROOMS, AREAS APPROACHING BEDROOMS, VAULTED CEILING WITH RISE OF 24" & ON EACH FLOOR) EXHAUST -FANS 1r .00 , kitdhen 50 Q04 bathroo Is. &-1atindr'y k/CIJ " )(Te: td"" N1101.3.1- Attic insulation certification required as to R — value or coverage. Markers, attached to trusses or rafters, required for every 300 sf of attic space with 1 inch high numbers for installed thickness of insulation. -OAP' focf cf tDooR cl,05.e7 1j. p0'6,64.Doll • SAFETY GLASS `F- J<nu it G-L,% 3 bOa LANDING required on both sides of exit doors with min. size of 3 ft. measured in direction of travel by 3 ft. or width of door if greater, and not lower than 1 %z in. below threshold. Landing required at other exterior doors is a minimum size of 3 ft travel distance by width of door, and not lower than 7'/4 in. below SAFEEy 'r,S 1� eV w t- -i T %(AN QOi HALM t KPow 4' 3'G Min.4 ft Brace Wall Panel per R602.10.3 & R602.10.4 Min. 2 ft 8 in. Alternate Brace Wall Panel per R602.10.6 Min. 16, 18 or 20 in. APA Portal Frame Bracing Engineered Shear Wall Bracing 30# felt for ice dam protection C `re 2.3 , nl So'� e"T``At°2`MMOFING MATERIAL ROOFING PAPER 1/8" GAP BE i'WVEEN SHEATHING namti +S31— SHEAT ING SOLID BLOCKING BETWEEN.TRUSSES WALL SHEATHING —71 .,a SIDING 1 6" MIN. 1 24" MIN. 1 7' 6" MIN. 4 r. 41 (ENGINEERED TRUS OR RAFTER SIZE AND PACING x 24.. O C. � 1S ven por '11kkr C.t.'iL ntT Attic Ventilation Ft per every 300 Sq Ft of space lated with at least 50% in the upper on of roof area. Attic Accessible bv22'x3©' DOUBLE TOP PLATE WALL HEIGHT ? CEILING: %z" GWB if perpendicular to rafters or trusses 24" o.c. and no water based texture used — otherwise 5/8" GWB. Y 2x G, @ cL O.C. PRESSURE TREATED SOLE PLATE Mfg) 2X'o '.Tots-rj E 2.c4 o C 3 0 ANCHOR BOLTS tit"xS MIN. (7" INTO CONCRETE) 6' 0. C. OR APPROVED ANCHOR INSTALLED PER MANUFACTURER. 6"x12" FOOTING