Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
1994, 07-18 Permit App 94006624 Residence, Garage
PROJECT NUMBER= 94006624 APPLICATION DATE= 07/18/94 PAGE= 01 ****** THIS IS NOT A PERMIT ****** PENALTIES WILL BE ASSESSED FOR COMMENCING WORK WITHOUT A PERMIT SITE STREET= 822 N CORBIN CT ADDRESS= GREENACRES WA 99016 PARCEL#= 55182.2943 PERMIT USE= RESIDENCE/ATTACHED GARAGE - ELECTRIC PLAT#= 005409 BLOCK= 1 AREA= # OF BLDGS= 1 PLAT NAME= LOT= F/A= # DWELLINGS= BROADWAY (COURT) SUBDIVISION 5 ZONE= UR-3.5 DIST#= G F WIDTH= 100 DEPTH= 129 R/W= 50 WATER DIST = CONSOLIDATED IRRG #1 OWNER= HOMESTEAD CONSTRUCTION STREET= 312 S FARR RD ADDRESS= SPOKANE WA 99206 CONTACT NAME= CHRIS SWANSON BUILDING SETBACKS: FRONT= 25 LEFT= 30 PHONE= 509 926 0755 PHONE NUMBER= RIGHT= 5 REAR= 20+ ****************************** REVIEW INFORMATION ***************************** DEPARTMENT BUILDING REVIEW REQUIREMENT PLAN REVIEW REQUIRED APPROVAL: G. KREINKE BUILDING SETBACK REVIEW REQUIRED APPROVAL: OK D. DOMPIER ENGINEER APPROACH/FLOOD PLAIN/DRAINAGE APPROVAL: 94FNA852 APPD S. LIGHTFOOT DATE: 07/18/94 DATE: 07/15/94 DATE: 07/15/94 HEALTHDIST NEW OR ADDITIONAL WASTE WATER , .�Q r\``R\ k4 COMMENTS: PERMIT TYPE BUILDING PERMIT MECHANICAL PRMT MISC FEES DUE PLUMBING PERMIT FEE AMOUNT 586.84 30.00 30.00 84.00 730.84 PROCESSED BY: BURRIS, ROBIN PRINTED BY: CHRISTY HARGRAVE AMOUNT PAID AMOUNT OWING .00 .00 .00 .00 586.84 30.00 30.00 84.00 .00 730.84 PROJECT NUMBER= 94006624 APPLICATION DATE= 07/18/94 PAGE= 02 ******************************** THANK YOU ************************************ APPLICATION WORKSHEET General Information Job address Owner Pamei number 9q-66)(( Mailing address city Phone Slate Zip i Site Information LeplDeacnptton t Oir: Property size WaterUulnct Number Uweutnga Swldtnga Zone Inspector Koad width Project Information Permit Use New Addition Kemode hae or 1 ti Building Information 1 Dwelling units Occupant toad Building height Stones i Building dimensions 1 otal square footage Keq'd parking I Handicap parlung Spnnkler system 1 Cnttcal Ma tens! Sguairc (oola a breakdown Mein floor \--.Th_ —l-,\ LTovered/covered deck J Second floor Other Finished basement Unfinished basemen) , Garage Contractor Information HesiinLaad insulation information (R—valuu) Hes I source Flat ceiling Vaulted ceiling Above grade wall Below grade wall Floor Slab on grade Door (u —value) Window Furnace etlioency total window area i % or floor area ♦ Bualding contractor -Plumgsog coorraclor Ltccnse number Phone License number f Phone Mailing addreu Ma tang addrcu Cily, stale, zip City, stale, zip Healing contractor Other/ Leader License number \ - Phone License number Phone Marling address Mailing address uy,sale, zip ty,aa e,zip PROJECT CONTACT PHONE Spokane County Division of Buildings 1026 West Broadway Ave * Spokane, Wa 99260 * (509) 456-3675 PLUMBING PERMIT APPLICATION PROJECT ADDRFSS: OWNER: PHONE: MAILING ADDRESS: (street) CONTRACTOR: (city/state) (LP) LICENSE: PHONE: MAILING ADDRFS.S: (street) (city/state) PLUMBING FIX I URLS DESCRIPTION DETAIL # OF UN] 1S MVUi- PULP G Y COST /UNIT ecu AMOUNT B02 B03 TOILETS URINALS B04 TUBS B05 B06 B07 B08 B09 SHOWERS (per trap) SINKS DISHWASHER CLOTHES WASHER GARBAGE DISPOSAUGRINDER WATER CLOSETS, BIDETS BA T11, JACUZZI. SPA, GARDEN BASE, STALL, ON -SITE BUILD LAVSBASINS, BAR, FLOOR. KITCHEN. LAUNDRY, UITLTCY, JANITOR. PHOTO, X-RAY. FOOD (PR EP/CutD4AR Y(MEAT) 'Z. 5 x x x x x x x x 56 = 5 56 = S S6 = S 56 = S S6 56 56 56 B10 B11 B12 WATER SOFTENER ELECTRIC HOT WATER TANKS (NOTE: J p, rnlcr task, 'e mocha Ical) FLOOR DRAINS AREA. CASE. COIL, TRENCH, CONDENSATE B13 ROOF DRAINS/OVERFLOW DRAINS (ea) B14 B15 B16 B17 FOUNTAINS, DRLNICNG WATER PIPING/DRAIN—WAS 1 b— VENT SEWAGE EIE.IU RS WATER USING DEVICES INSTAL.LAT1 ON, ALTERATION OR REPAIR OR CIDER, SUMP PUMP. ICE AND/OR CO EPEE MAKER. HOSE BIB, STEAMER, PROOFER, CARBONATOR, $W AMP COOLERS x x x x x x x x S6 S6 56 S6 S6; = 56, = $6 56 = S 5 5 = 5 = 1318 B19 CROSS —CONNECTION DEVICES INTERCEPTORS VACUUM BREAKER.CHECK VALVE, AND R.P.B.P,D, POR: VATS. SUMPS, TANKS, BOILERS, t SPRrNKLER SYSTEMS O R EASETRAP, SAND TRAP, CHEMICAL HOLDEN° TANK x x 56 56 5 B20 B21 MEDICAL GAS (per outlet/souk station) MISCELLANEOUS FDCTURFS NITROUS, OXYGEN NOTE; MINIMUM PERMIT FEE IS $35.00 SIGNATURE: x x $6 = 5 S6 = S Subtotal PLUS: PROCESSING FEE I S25,CQ TOTAL PERMIT FEE DUE S SPOKANE COUNTY DIVISION OF BUILDINGS WEST 1026 BROADWAY AVLIUUE • SPOKANE, WA 99260 • (509) 456-3675 WASIVAV{LMPIR,U IND MECHANICAL PERMIT APPLICATION PROJECT ADDRESS: OWNER: MAILING ADDRESS: 7 (PHONE: (street) CONTRACTOR: (city/state) (z'P) LICENSE: • PHONE: MAILING ADDRESS: street) city/state zi DESCRIPTIONQF WORK # OP UNI"IS •nan- .IL.O•T COST /UNIT .m,,,, ANOU'"I 1302 FUEL BURNING APPUANCE -«<too,000 $12 B03` FUEL BURNING APPLIANCE >100.000 $15 . , )304 . Of <ao,000 S50 UNLISTED FUEL BURNING APPLIANCE 1305 UNLISTED FUEL BURNING APPLIANCE >wo.000 5100 B06 USED APPLIANCE (Must roc et WSEC's min. AFUE rating) • or <wo,coo S50 . B07 USED APPLIANCE (Must meet WSEC's ruin. AFUE rating) >ioo,000 S100: 1308 BOILER/REFRIGERATION t-iOPM BTU S12 B09' BOILER/REFRIGERATION tot -loom vms S20 . 1310 BOILER/REFRIGERATION 3.01-1,o00M ETV 525 • I311 BOILER/REFRIGERATION 1,001-t,7soMBTU S35 . B12 BOILER/REFRIGERATION +1,75oM BTUr • SW . B13 GAS LOG, GAS ENS ERT, AND/OR GAS FIREPLACE - S 1 0 . B14 RANGE - 510 . )3151' DRYER - $10 816 FUEL BURNING WATER HEA1 b. R - $10 - 1117 MISCELLANEOUS FUEL BURNING APPLIANCE - S 10 . B18 GAS PIPING (ea. outlet) - 51 - B19 - S10 • DUCT SYSTEMS 1320' VENTILATING FANS - 1 $10 B21 AIR HANDLER (DOES NOT include dua systems) . or <10,O3oC FM $12 822 AIR HANDLER (DOES NOT include duct systems) > to,000 CPns S 15 B23 EVAPORATIVE COOLERS - S10 B24 TYPE I HOOD - S50 B25 TYPEIIHOOD - S10 - i B26 HEAT PUMP/AIR CONDITIONER o-STOIC $12 B27'. AIR CONDITIONER 4-15TOMS S20 . 822 AIR CONDITIONER 16-3o TONS $25 . 829 AIR CONDITIONER 51-50TOPC S35 . B30 AIRCONDFTIONER +soTor:s 560 1331 LPG STORAGE TANK - S10 B32 WOOD OR PELLET STOVE/LNSERT - S25 NOTE' MINIMUM PERMIT FEE ISS35.00 Subtotal PLUS: PROCESSING FEE 525.00 TOTAL PERMIT FEE DUE SIGNATURE: m .,i • Am•tl,p• SPOKANE COUNTY DIVISION OF BUILDINGS WEST 1026 BROADWAY AVENUE • SPOKANE, WA 99260 • (509) 456-3675 WATTSUN 5.1 I V ENERn, COOE COMPLIAN[E REPORT =====' 09/19/` FILE: BKTR74.W'�; PanRvvivwedBy: 0.fento.` (589)480 K? This plan revewIspruviueu^,,/aWvn,"�.� purposes only, and does oc| yu^mm,p compliance with local, state o,/oelara1 .odes p,requirements, Mail: ^ 4nalyst; Dp Curis6iction: Utility: 00P HO(SE ID� TRl L[r Builder: HOMESTEAD CONSTRUC|lnN weather Dataq Spokane. WA .� � The PROPOSED design *COMPLIES* with 1"91 WA State Energy CoUe� / : COMPONENT PF RFORMANCE | ENERGY BUDGET I .�REFERENCE DESIGN �ROPOS�D 265 Btu/hr-F 5,65 4 Wh/ft2-yr � Component Area = UA { � BG Wall y_0�41 3O9 12. � 8G Slab F-C 640 S8ft 56 ` � � � Floor U-0,029 574 16., / Glazing @15% 1/-0 , � 400 220 4 88_ - � / Doors U V�2�0 � 20.0 1.� AG Wa`ll 160.044 1289 5b, � Ceiling U-3.031 1021 31, � Infiltration - I I -PROPOSED DESIGN COMPONENTS �1 � Component Descrip{ion ___________ Reference � A ------------ -- BG Wall R19 hart 3.n depth U-0,041 308 12 DO Slab F-0.640 88ft 56 Floor R30 vented Joist 16oc U-O.029 528 15 R30 unvenLed Joist 16U-0029 46 l Glazing @11% **WP VINYL 2 GL LOW E U-01390 165.0 64_�� Doors Metal R-5 base case U-3.190 20.0 AS Wall R19 STD Lap Wood U-0.062 1343 83 Ceiling R49 blown Attic STD bw+fled U-0.027 1021 27,' ---------------------------- � � Items in parentheses not included in �OnPO�ENT PERFORMANCE totals " °° . /rcs non-standard values - chec, aiculation of thermal value. 1 �r� : =======================,____-___ •WATTSUN 5, 1 1991 WA STATE ENERGY CODE: COMPLIANCE REPORT 09/19/9. FILE::••E:\TRIA.WS HOUSE ID: TRI IEVE::i Infiltration Standard Air Sealing ACH-0.350 10440ft3 ( 63.2. Proposed UA 267 Struc Mass Light Frame, Sheetrock. walls M-C.000 1469 4407.0 HEATING/COOLINS/VENI-ILATING SYSTEMS Heating System Type: Make: Model: PROPOSED Electric: Zoned •System Efficiency: 100 Modified Efficiency: 100 7. Heating Load(at 66F dt): System Size: Maximum Size @1507..: 24614 Stui hr 7.2 kW 10.8 kW Average Annual Heat: 10788 kwh Annual Cost: Ventilation Type: Option: Cooling Load(at 12F dt): Recommended Size @11257.: f 59:'_ Non --Heat Option Fie co 19069 9tu/hr 2.2 tons r-y aotia Partially Solar Access:F Shaded GLAZING ORIENTATION South: Southeast.: East: Northeast: PROPOSED 41.2 it2 0.0 41.2 C>,ii North: Northwest: West: Southwest: PROPOSED 41.2 f t2 0.0 - 41.2 0.0 Economic; and energy consumption estimates are designed for comparative purposes only. Actual cost for heatinn w.i.11 vary depending on weather Conditions, occupant lifestyle and other factors. Yvvfe v.-s 5P CT-Y HEALTH too — -,--- JUL-20-'94 09:47 ID:UTILITY SPa o7:48 W09 324 1587 07{40l04 • • • • • j 'I 1,! -I- ®""-- 1 . IF YOU CANNOT INSTALL THIS SYSTEM ACCORDING TO THIS APPROvEP PUN, YOU MUST CA'.L THE OFFICE AT 324.560 PRIOR TO INSTALIATlaN,, • I •• .. • DOUBLE PLUMBINU USE 4" PVC PIPE ASTM D-3034 SDR35 OR ASTM F1R9 AT 2% SLOPE REFERENCE CAPPED ENDS AND CLEANOUT • ,---r SPECIFICATI EWAGS SYSTEM! : r " a 1 SQUARE FOOTAGEs. f WIDrH; i.� ►. • n 0• 9 ... .,PEPTH•FROM• _OJTOUND .pU]R, GE T0401TO11 1F SEWAtiE••SYSTEtt; 1 % S' OTHER' SIGNATURE: MEIER DATE; EXPIRES 06122J75 INSTALL 4' CURB INLET STA 3+32.65 10.08' RT TOC EL 96.12 CUT EL 95.62 10' UTILITY EASEMENT SCALE 1 "=20' BERM EL 96.32 SWALE BOT. EL 95.12 INSTALL SOD OR GRASS TURF L=15.22' (ARC) R= 67.50' 20.50' 2' • • DRA NAGE EAS MENT L=21. ; 8' (ARC) R= 70.50' COUNT -'PROJECT P-1712 LOT 5 BROADWAY SUBDMSION c FiffMraltrif ENGIACt 5 • 5C.RVEYOr 5 1. ttww�lw pa r,�s so ICI 71w1 In )(m) 74e-1301