1988, 05-27 Permit 88001102 InspectPROJECT NUMBER= 88001102 DATE= 05/09/88 PAGE= Oi
ISSUED PERMIT
_
*************************** PERMIT It
SITE %TREET= i7922 E COWLEY AVE
ADDRE%%= GREENACRE% WA 99016
'it
TION
_
'
PARCELO= 0554-1548
'
PERMIT U%E= RESIDENCE ADDITION ON EX1%TING DECK - KITCHEN & DINING
PLATO= 000500 PLAT NAME= CORBIN ADD TO GREENACRE%
BLGCK= 17 LOT= ZONE= AGRI DI%T*= C,
AREA= 00000000 F/A= F WIDTH= 2 DEPTH= 161 R/W= 50
0 OF BLDG%= 2 0 DWELLING%= i
OWNER= BROWN %R, FORRE%T E
%TREET= 17922 E COWLEY AVE
ADDRE%%= GREENACRE% WA 99016
PHONE= 509 928 4077
CONTACT NAME= OWNER PHONE NUMBER-:
BUILDING SETBACKS: FRONT= EXI% LEFT= EXI% RIGHT= EXI% REAR= EXIS
******************************* BUILDING PERMIT ****************************
CONTRACTOR= OWNER PHONE=
NEW= REMODEL= ADDITION= X CHANGE OF USE.-:
DWELL UNIT%= i OCCUP. LD= BLDG HGT= 8 %TORIE%= i
'`BLDG W X D = iO X 16 %Q FT= 160
' REQ PARKING= OHANDICAP= %EWER= N HYDRANT= N
ENERGY CODE= NWEC UTILITY= WWP
DESCRIPTION GROUP TYPE %Q F� VALUATION
----------- ----- ---- ----- ---------
-
RE% ADD R-3 VN -16O 4800.00
ITEM DESCRIPTION QUANTITY FEE AMOUNT
------------------------- -------- ------------
RESIDENTIAL VALUATION Y 72.00
STATE SURCHARGE Y 3.5O
******************************* PAYMENT SUMMARY ****************************
PAYMENT DATE RECEIPTO PAYMENT AMOUNT
05/09/88 1446 75.5O
TOTAL DUE= DUE= .00 TOTAL PAID= 75.50
PERMIT TYPE FEE AMOUNT AMOUNT PAID AMOUNT OWI%
--------------- ------------- ------------ -------------
BUILDING PERMIT 75.50 75.5O .00
------------- ------------ -------------
75.50 75.50 .00
* PROJECT NOTE: TOPIC = GENERAL DEPT = BUILDING & SAFETY *
****************************************************************************
_
DEPTH OF PIER FOOTINGS SHALL BE 36"' AND INSPECTED PRIOR
TO POURING OF CONCRETE. jFOUNDATION% SHALL MAINTAIN A 5'
/.
PROJECT NUMBER= 8800102
DATE= 05/09/88
ISSUED PERMIT
P A G E = O3
************************** ENERGY INFORMATION ****************************
SITE %TREET= 17922 E COWLEY AVE
ADDRESS- GREENACRE% WA 99016
'
PARCEL#= 18554-1540
PERMIT USE= RESIDENCE ADDITION ON EXISTING DECK - KITCHEN & DINING
NEW= REMODEL=
ENERGY CODE= NWEC
APPROACH= PER%CRIPTIVE
COMPLEXITY=
ADDITION- X CHANGE OF U%E=
DESCRIPTION
-----------
RE% ADD
CEILING, FLAT:
CEILING, VAULTED:
WALL:
WALL, BELOW GRADE:
FLOOR OVER UNC. SPACE:
SLAB FLOOR PERIMETER:
_WOMMENT%:
UTILITY= WWI::,
GROUP
-----
R-3
TYPE
VN
ENERGY CODE PLAN REVIEW
R-49
N/A
R-i9A
N/A
R-3O
N/A
%Q FT
-----
160
RE%/COM= R
**************************
DOORS MAX. U-VALUE: N/A
GLAZING MAX U-VALUE: 0.40
GLAZING MAX AREA: 15%
AIR LEAKAGE SYSTEM: STD
SPACE HEATING SYSTEM: BASEBOARD
****************************************************************************
I HAVE BEEN ADVISED OF THE FINANCIAL INCENTIVES AVAILIBLE FOR THE STRUCTURE.
DESCRIBED ON THIS PERMIT, AND THAT THE ENERGY CONSTRUCTION MEASURES FOR
UAh*z --INCENTIVE% WILL BE PAID ARE A REQUIREMENT OF THIS PERMIT, AND THAT
THE %TMUST RECEIVE FINAL APPROVAL BY MARCH 31, 1989 TO RECEIVE THE
INCENTIVE PAYMENT. I ALSO UNDERSTAND THAT NEITHER T}HE BONNEVILLE POWER AD --
MINISTRATION NO' %POKANE COUNTY MAKE ANY WARRANTIES AS TO ACTUAL ELECTRICAL
SAVINGS TO BE REAL'ZED^__OR ANY OTHER EXPRESSED OR IMPLIED WARRANTY CON-
CERNING THE MATERIALS EMPLQYED IN~THE CONSTRUCTION OF THE STRUCTURE...
�--'_
I HAVE BEEN ADVISED OF 'INTEND TO-COMp Y WITH THE NORTHWEST ENERGY CODE
REQUIREMENT% PERTA TO FORMALDEHYDE FOR STRUCTURAL
COMPONENTS, AND''HAVE RECEIVED A COPY OF EXHIBIT 9(A) WHICH DESCRIBES THE%E
~ REQUIREMENT -��
APPLICANT
AUTHORIZED OFFICER
DATE
******************************** THANK YOU *********************************
7..
i
!
7 --- -:
1
----I-- ---i
!
1
1
1
_
_
1 -
-
1
, 1
i
---.
i
.
,
1
..._
_. .
-..
,
,
1
•
r-
Job Addres. 111 22 Coin F.i. f N4
County of Spokane Energy
Northwest Energy Code Inspections
BUILDER/INSPECTOR CHECKLIST 456-3675
r SLAB INSPECTION - PRIOR TO PLACING SLAB
ji'GRAVEL BASE: A 4 inch thick coarse -grade gravel base shall be in place.
IV/Pr PERIMETER INSULATION: All slab perimeters within 24 inches of the final exterior grade shall be insulated to at least
R-10. Insulation shall be 24 inches in length overall and installed in an approved manner.
INSULATION AND SEALING INSPECTION
APPROVED PLANS are available on the job site.
WINDOWS AND DOORS: All windows and doors shall be as specified on the approved plans. The rough opening around jambs,
silts and headers shall be sealed to prevent air infiltration. These areas may be either caulked or foamed, but must be
sealed airtight.
L SOLEPLATE CAULKED: Soleplates of walls shall be caulked or glued to the floor.
PLUMBING AND ELECTRICAL PENETRATIONS: All holes in the buiding envelope shall be sealed to prevent air infiltration.
Where electrical wiring passes horizontally through a wall stud, no sealing is required unless that stud penetrates the
building "envelope." Electric boxes throughout the building shall either have the holes and edges sealed or be provided
with plate gaskets. Rim joists, mudsills and plumbing stacks shall be sealed.
WALL INSULATION: All wall cavities shall be filled completely to the required insulation value. Batts shall not be
compressed_ Batts must be cut to fit around wires, pipes and outlet boxes. Kraft or foil vapor retarders must be
face -stapled.
' FLOOR INSULATION: Floor insulation shall be installed to the required R-value, and shall be supported in an approves
manner with twine, wire, "Tyvek," netting, etc. Avoid compressing the insulation.
!/CEILING INSULATION: If eave vents are used, approved baffles shall be in place to permit adequate ventilation through
eave vents_ Blown insulation may not be used if the ceiling slopes more than 2-1/2 in 12.
AF/� DUCTS: Ducts shall be sealed at joints and corners with duct tape or sealant. Ducts outside of the conditioned space,
except exhaust air ducts, shall be insulated to R-11. Exhaust air ducts shall extend to the exterior of the building.
VAPOR RETARDERS: A vapor retarder is required on the warm side of insulation in walls, floors, and ceilings. Approved
materials include: 6 mil. polyethylene, Kraft or foil paper face -stapled, exterior grade plywood and certain flooring
materials.
pG CRAWL SPACE: Screened ventilation openings shall be provided at a rate of not less than one square foot for each 300
square feet of under -floor area.
* FINAL INSPECTION (ENERGY)
APPROVED PLANS are available on the job site.
MECHANICAL SYSTEMS: All iechanical systems will be checked for correct operation and labeling of controls.
Heaters shall be siz:d as shown on the approved plans.
Exhaust fans shall b: properly located and shall be properly rated for size and
Exhaust ducts shall be provided with a tight -fitting backdraft damper.
The whole house exhaust fan shall be controlled to operate automatically as wel
Make-up air intakes shall be properly located and sized.
WEATHERSTRIPPING:
/'.- Weatherstripping shr..l be aligned for proper seal on exterior doors, incl
threshold or sweep s all be properly adjusted.
/7/--4 Attic hatches and interior crawlspace access hatches shall be weatherstripped a
Windows shall be weatherstripped and locking mechanism checked for proper funct
(----Electrical switch and outlet plates throughout the building shall be fitted w
prior to the insulation inspection.
ATTICS:
Insulation shall be of thickness specified by the manufacturer to comply with r
PLUMBING:
/1/1T' Hot water heaters shill meet the ASHRAE 90A-80 specifications.
fr_ Showers shall be equ:oped with flow restrictors allowing a maximum flow of 2.75
/r
FIEPLACES / WOOD STOVES:
Fireplaces and wood !toves shall be equipped with "tight -fitting" metal or glas
noise.
l as manually.
uding doors into unheated spaces. Door
Id insulated.
ion.
ith gaskets, unless the boxes were sealed
quired R-values.
gallons per minute per shower head.
s doors.
A combustion air int:ke shall be ducted directly into the firebox. The intake duct shall be at least six square inches
in area and shall be aquipped with a readily accessible, operable tight -fitting
CRAWL SPACES:
A ground cover of 6 mil. black polyethylene or equal shall be installed on
lapped at least 12 ir:hes.
INDOOR AIR QUALITY:
During the final ins?ection of occupancies which are eligible for incentive.
leave a pre -paid paitcard, which offers a free radon monitor, and a backgr
quality.
damper.
all crawl space floors. Joints shall be
payments, the energy code inspector will
>under booklet from BPA about indoor air