Loading...
2008, 03-06 Permit 08000666 Wall Panel, Brace CalcsWALL PANEL AND BRACE CALCULATIONS FOR CLASSIC WALL PANEL (Pages 1-13) Prepared for: TECHNICAN PACIFIC INDUSTRIES, INC. 383 ELGIN STREET BRANTFORD, ONTARIO N3P5W4 Prepared By: SCHAFER ENGINEERING ASSOCIATES 1885 State Street Schenectady, New York 12304 Phone: (518) 393-4767 Fax: (518) 393-3510 Void without signature; raised eI 0termark. Not for use in Master Permit fjpplic-tons. Issue No. 28-5735 Expiration Date: 6/19/09,9y kor Installation Address: Tim Parker, 14222 E Crown, Spokane Valley WA 99216 TECHNICAN PACIFIC POOLS, INC Classic Wall Panel Calculation Assumptions: a.) The panel ends provide minimal vertical stiffener reinforcement for the galvanized steel pool panels. Therefore, the critical case for calculating vertical stiffener strength occurs when a 3 foot panel is sandwiched between two 7 foot panels. b.) The concrete pour at the base of the wall (i.e., bond beam) provides 10 inches of vertical support to the panels, stiffeners and braces. c.) Refer to the last page for more Material/Installation Assumptions. Definition of Parameters: Assumed Soil Properties: (Sandy silt soil material) Wd (unit weight of dry soil) 105 Ib/ft3 VW (unit weight of saturated soil) 135 Ib/ft3 c (soils interior angle of friction) 30 degrees Ka (lateral active soil coefficient) = tan2 (45-0/2) 0.333 yd (equivalent active unit weight of dry soil) = Ka Wd 35 Ib/ft3 7e (equivalent active unit weight of saturated soil) = KaWW 45 Ib/ft3 yW (unit weight of water) 62.4 Ib/ft3 (friction factor between soil and concrete) 0.45 Material Properties and Dimensions: Panels/Stiffeners/Channels E (modulus of elasticity) 29,000 k/in2 Fy (minimum yield stress of cold -formed steel) 42,000 Ib/in2 Fb (allowable bending stress of cold -formed steel) 25,150 lb/in2 Fb,plate (allowable bending stress of cold -formed plate steel) 31,500 Ib/in2 Ft (allowable tensile stress of cold -formed steel) 25,150 Ib/in2 tp (thickness of panel, stiffener, and channel steel) 0.0720 in h (height of panel) 3.5 ft hW (depth of water) 3.0 ft heff (effective height of panel) 2.67 ft b3 (maximum unstiffened 3 foot panel width) 3.0 ft b7 (maximum unstiffened 7 foot panel width) 3.5 ft R (maximum radius of panel) 29 ft Ls (effective height/length of stiffener = heff) 2.67 ft d (nominal depth of stiffener) 5.0 in Lc (maximum brace spacing) 8.0 ft Se,s (section modulus of stiffener) 0.5973 in3 bs (maximum unsupported length between stiffeners) 10.0 ft Se,e (section modulus chi rj el) 0.6464 in3 Void without signature, rtis Not for use in Master P Expiration..Date:..6/19i color watermark. Schafer Engineering Associates tions. Issue No. 28-5735 1 of 13 For instaation Address: Tim Parker, 14222 E Crown, Spokane Valley WA 99216 l TECHNICAN PACIFIC POOLS, INC Classic Wall Panel A307 Steel Bolts Ft Fv s db (tensile stress of the bolt) (shear stress of the bolt) (bolt spacing) (bolt diameter) Concrete Bond Beam F'c (compressive strength of concrete) tc (thickness of base pour) wc (width of base pour) (unit weight of concrete) (moment arm) 7c am Angled Braces/Rods Fy Fa ra A. La Lr dr rr k (minimum yield stress of steel) (allowable axial stress) (radius of gyration of angle) (area of angle) (maximum length of angle) (maximum length of rod) (rod diameter) (radius of gyration of rod) (effective length factor) Analyses: 1. General Panel Configuration 20,000 10,000 6 0.3750 Ib/in2 Ib/in2 in in 2,500 Ib/in2 10 in 2.0 ft 145 Ib/ft3 See Calculations 36,000 Ib/in2 9th Ed. ASD pp. 3-16 From Spreadsheet From Spreadsheet 44 19 0.500 0.125 1.0 PAN CO. EO. EO. 8-OXPANEL XI I 7.- 1A- .--- J� I - PANEL Y - EO. • , J E.O. ASSIC WALL PANEL Void -without signature, raised l Id color watermark. Not for use in Master Permit /qp liceeions. Issue No. 28-5735 Expiration Date: 6/19/0. Q*PciOnstailation Address: Tim Parker, 14222 E Crown, Spokane Valley WA 99216 in in in in Schafer Engineering Associates 2 of 13 TECHNICAN PACIFIC POOLS, INC Classic Wall Panel 2. Loading Conditions: (Calculated per unit foot of wall.) A. B. Dry Backfill, Pool Full Total lateral dry soil load [Pd] = Total lateral water Toad [PW] = yd x h2 _ 35 x 3.5 2 = 214.38 Ib/ft 2 yw x hw2 2 2 62.4 x 3.0 2 _ = 280.80 Ib/ft 2 Total lateral Toad per unit length [P] = P.- Pd = 280.80 — 214.38 = 66.43 Ib/ft p 66.43 Approximate distributed panel Toad [Pne] = _ =18.98 Ibfft2 h 3.5 Saturated Backfill, Pool Full ysxh2 Total lateral saturated soil load [Ps] = 2 = 45 x 3.5 2 2 = 275.63 Ib/ft Total lateral Toad per unit ngth [P] = P. - Ps = 280.80 — 275.6 = 5.18 Ib/ft p 5.18 Approximate distribtd,p,load [Pnet] _ = = 1.48 Ib/ft2 h 3.5 Void-without-signat eetl se,and color watermark. Not for use in Mast�eknit Applications. Issue No. 28-5735 Expiration Date: 6/19/09 Only For Installation Address: Tim Parker, 14222 E Crown, Spokane Valley WA 99216 Schafer Engineering Associates 3 of 13 TECHNICAN PACIFIC POOLS, INC Classic Wall Panel C. Dry Backfill, Pool Empty (See Material/Installation Assumptions) • Pd Total lateral dry soil load [Pd] = 214.38 lb/ft Pd 214.38 Approximate distributed panel load [Pnet] = _ = 61.25 Ib/ft2 h 3.5 3. Flat Plate Analysis: (7'-0" panel length governs as maximum spacing between vertical stiffeners occurs with this panel. See Calculation Assumption b.) Largest unsupported panel area: 2.67 ft x 3.5 ft Modify lateral soil load to determine actual load acting on panel parts by taking concrete bond beam into account. (Load Condition 2c governs and assumes overturning/sliding analysis requirements are met.) ydxheff2 35 x 2.672 P' = 2 2 = 124.44 lb/ft Approximate distributed panel load [P'net] = P' Actual bending stress [fb] = h22b42 2tp ((hhart +b4 ) [fb] = 20,251.40 Ib/in2 F.O.S. = Fb 31,500 fb 20,251.40 P' _ 124.44 = 46.67 ibift2 hell 2.67 2 2 46.67 x 2.67 x 3.5 2 x 0.0720 x ( 2.67 2 + 3.5 2) = 1.56 >1.00K Void without signature, raised sal d color watermark. Schafer Engineering Associates Not for use in Master Permit nations. Issue No. 28-5735 4 of 13 Expiration Date: 6/13F.Q9.dnly For -installation Address: Tim Parker, 14222 E Crown, Spokane Valley WA 99216 TECHNICAN PACIFIC POOLS, INC Classic Wall Panel 4. Radial Panel Analysis: (Tensile hoop stress. Load Condition 2c governs and modified lateral distributed panel Toad [P'net ] from Section 3 applies.) P'net R Actual Tensile Stress [ft] = tp 46.67 x 29 x (1/12) ft = = 1,566.36 Ib/in2 0.0720 Ft 25,150.00 F.O.S. = ft 1 566.36 16.06 > 1.0 OK 5. Bending along Vertical Axis at Vertical Stiffener:(See Calculation Assumption a.) 7' WIDE PANEL VERTICLE 'Z' ORIENTATION P' BRACE BRACE POINT 7-0" L POINT ca co u -o FLANGE =1.125 FLANGE — tp=0.072 WEB Modified lateral soil (P') from Section 3 applies: (Load Condition 2c governs.) Maximum bending moment [Ms] = 9P (2S + 2 ) 2 x 124.44 x 2.7 10.0 3.5 Ms = 9 ( + ) = 287.39 ft-lb 2 2 Actual bending stress [fb] = Ms Se,S F.O.S. = Fb fb 25,150 ,7 3 287.39 x 12 0.5973 4.36 > 1.0 OK = 5,773.82 Ib/in2 Void -without -signature; r 'tsed a `al d color watermark. Schafer Engineering Associates Not for use in Master P rXpplica ions. Issue No. 28-5735 Expiration Date: 6/19/09e Or y For Installation Address: Tim Parker, 14222 E Crown, Spokane Valley WA 99216 5 of 13 TECHNICAN PACIFIC POOLS, INC Classic Wall Panel 6. Bending in the Top Channel: (8'-0" panel length governs as maximum spacing between braces occurs with this panel.) BRACE POINT PLAN FLANGE =1.25 BRACE POINT d=5 /— FLAN GE=1.25 0 I I a L' WEB CHANNEL X—SECTION Modified lateral soil (P') from Section 3 applies: (Load Condition 2c governs.) Load along the channel [Plop] - p' 124.44 3 3 = 41.48 ibift2 41.48 x 8.0 2 Maximum bending moment [M°] = P`°P L°2 = = 331.85 ft-Ib 8 8 Actual bending stress [fb] = M` Se,c F.O.S. = Fb fb 331.85 x 12 0.646 25,150 _ = 4.08 > 1.0 OK 6,160.62 = 6,160.62 Ib/in2 Void withoutsignature rat al and color watermark. Not for use in Master Pe. App Lions. Issue No. 28-5735 Expiration. Date:.6/t9/09Cnly For Installation Address: Tim Parker, 14222 E Crown, Spokane Valley WA 99216 Schafer Engineering Associates 6 of 13 TECHNICAN PACIFIC POOLS, INC Classic Wall Panel 7. Overturning Analysis: (Moments taken about point A with concrete bond beam in place. Calculated per unit foot of wall. Load Condition 2c governs.) + Pd E 0 4 wc PC ,A C m 1 = (Wc/2)+d E Mresist = Mack + Mconc = Pbam1 + Pcam1 = Wdheffwcaml + Yctcwcaml = 105 x 2.67 x 2 x 1.42 + 145 x 0.8 x 2 x 1.42 = 1,135.69 ft-Ib 2 E MOT = Msoii = Pd am2 = Yd 2 h am2 2 35 x 3.5 x 3.5 2 3 = 250.10 ft-Ib F.O.S. = E Mresist E MOT 1,135.6.9 = 4.54 > 1.5 OK 250.1 ' Void without signatu, ra eal and color watermark. Not for use in Mat A lications. Issue No. 28-5735 Expiration Date: 6`1�, Only For Installation Address: Tim Parker, 14222 E Crown, Spokane Valley WA 99216 Schafer Engineering Associates 7 of 13 TECHNICAN PACIFIC POOLS, INC Classic Wall Panel 8. Sliding Analysis: (Concrete bond beam in place. Calculated per unit foot of wall. Load Condition 2c governs.) b + Pc )u Presist = µb + Pc) = µ(Wd heffWc + yc tc wc) = 0.45 x( 105 x 2.67 x 2 + 145 x 0.8 x 2 = 360.75 E Psliding = Pd — yd h2 2 2 35 x 3.5 2 = 214.38 E Presist 360.75 F.O.S. =_ = 1.68 > 1.5 OK E Psliding 214.38 -o Void without signature, raised I color watermark. Not for use in Master Perm' l!cations. Issue No. 28-5735 Expiration..Datee6/19/09 criy F Installation Address: Tim Parker, 14222 E Crown, Spokane Valley WA 99216 a ',w S Schafer Engineering Associates 8 of 13 TECHNICAN PACIFIC POOLS, INC Classic Wall Panel 9. Brace (Angle Section) Analysis: (Assumes concrete bond beam in place and 8'-0" panel length for maximum brace spacing.) ILONG ANGLE 2'' x 2' x 44" 14 GA. GALVANIZED ANGLE LATERAL LOAD DIAGRAM ADJUSTABLE and STATIONARY AFRAME ASSEMBLY A.) Compression Analysis: (Load Condition 2a governs.) Max force at brace level [Pi] = Axial Compression Force [P..] = P 66.43 3 L= 3 8.0 = 177.13 Ib p, p, 177.13 = 371.23 Ib cos 0 cos ( 61.5) 0.4772 paxa 371.23 Actual axial stress [fa] = _ = 1,260.96 lb/in2 A. 0.2944 kLa 1.0x44 ra 0.4013 =109.64 Cc = 126.1 Fa = 11.72 Fa 11.720 F.O.S. = fa = 1.2610 9.29 > 1.0 OK Void without signatu , ais = == and color watermark. Not for use in Mastef App -tions_ Issue No. 28-5735 Expiration_Qate:_6/19/69'Only For Installation Address: Tim Parker, 14222 E Crown, Spokane Valley WA 99216 Schafer Engineering Associates 9 of 13 TECHNICAN PACIFIC POOLS, INC Classic Wall Panel Section Properties of Angle Brace - - VERTICAL LEG b= c= d= - - HORIZONTAL LEG b= h= c= 0.075 1.000 2.000 1.9250 0.0750 1.9625 - - PROPERTIES TOTAL SECTION c I = 0.0500 A = 0.150 I = 0.0001 Stop = 0.0018 Sbot = 0.0018 A = 0.1444 Ctotal = 1.4721 'total = 0.1182 Atotal = 0.2944 r x = 0.6337 k = -0.07081 la = 0.047412 ra = 0.401324 Void without signAture,;rai4dcs�Srwaterr rc. Schafer Engineering Associates Not -for "use in"Maa ter`PeQrm Ypphcations. issue No. 28-5735 pValley Expiration Date.yg For Installation Address: Tim Parker, 14222 E Crown, Spokane WA 99216 10 of 13 TECHNICAN PACIFIC POOLS, INC Classic Wall Panel B.) Tension Analysis: (Load Condition 2c governs and modified lateral load [P'] from Section 3 applies.) Max force at brace [Pi] = Axial Tension Force [PaM] = p124.44 3 Lc = 3 8.0 = 331.85 Ib 331.85 = 695.47 Ib cos 0 cos (61.5) 0.4772 695.47 Actual axial stress [fa] = _ = 2,362.35 Ib/in2 Aa 0.2944 21.600 F.O.S. = f a = = 9.14 > 1.0 OK 2.3623 Void without signature, raised �lor watermark. Not for use in Master Pernajt li ions. Issue No. 28-5735 Expiration_Date:_6/19/09.90yFor Installation Address: Tim Parker, 14222 E Crown, Spokane Valley WA 99216 Schafer Engineering Associates 11 of 13 TECHNICAN PACIFIC POOLS, INC Classic Wall Panel 10. Brace (Threaded Rod Section) Analysis: (Assumes concrete bond beam in place and 8'-0" panel length for maximum brace spacing.) A.) Compression Analysis: (Load Condition 2a governs.) paxe 371.23 Actual axial stress [fa] = _ = 1,890.63 Ib/in2 Ar 0.1963 kLr 1x19 rr 0.125 Fa = 6.46 = 152 Cc = 126.1 Fa 6.46 F.O.S. = fa = 1.8906 = 3.42 > 1.0 OK TURNBUCKLE 1/2-0 — 19- A307 THREADED ROD TURNBUCKLE and THREADED ROD AFRAME ASSEMBLY B.) Tension Analysis: (Load Condition 2c governs and modified lateral load [P'] from Section 3 applies.) Actual axial tensile stress [ft] = Paxt 695.47 Ar 0.1963 Ft _ 21.6 _ F.O.S. = ft 3.5420 6.10 > 1.0 OK = 3,542.02 Ib/in2 11. Steel Bolt Analysis: A.) Check Bolt Shear: (Load Condition 2c governs and modified lateral load [P'] from Section 3 applies. Refer to Section 9b of brace analysis.) pax 695.47 Actual bolt shear stress [fv] = _ = 6,296.93 Ib/in2 Ab 0.1104 F� _ 10,000 F.O.S. = f� = 6 296.93 1.59 > 1.0 OK B.) Check Bolt Tension Stress: (Load Condition 2c governs and modified lateral distributed panel load [P'net] from Section 3 applies. Refer to Section 4 of radial panel analysis.) Maximum tensile force [T] = P'net R = 46.67 X 29 = 1,353.33 lb/in of panel depth Actual bolt tensile stress [ft] = 20,00(5' ,. F.O.S. = = = 3.26 > 1.0 OK 6. Ft T S 1,353.33 x 6 x (1/12) J v- � Void without signat e, raise\,,t and color watermark. Not for use in Master Pe Tit:AQplications. Issue No. 28-5735 ExpirationDate:.6/19/0,O`Only I=br Installation Address: Tim Parker, 14222 E Crown, Spokane Valley WA 99216 Ab 0.1104 = 6,126.64 lb Schafer Engineering Associates 12 of 13 TECHNICAN PACIFIC POOLS, INC Classic Wall Panel 1. Material/Installation Assumptions Wall panel, brace and panel/brace fastener sizes, thickness, dimensional characteristics, material properties and strengths used in these calculations were provided by Technican Pacific Pools, Inc. These calculations assume that these elements have uniform thicknesses, sizes, and material properties/strengths and that they are free of defects. These calculations cover only those elements identified herein and do not cover liners, ladders, steps, slides, decks, railings, etc. This pool system is intended to be installed only by factory trained and approved distributors/contractors. 2. Soil pressures used in these calculations constitute those soils which are in their active state and have a maximum equivalent fluid pressure equal to 35 #/ft3 under non -saturated conditions and 45 #/ft3 under saturated conditions. See definition of parameters section for more soil type assumptions used in these calculations. These calculations do not consider the existence of expansive or adobe -type soils, high groundwater table conditions, or adjacent uncompacted soil fill conditions. If existing site soil conditions dictate a different or potentially higher equivalent fluid pressure than those used herein, the pool Purchaser/Installer shall contact a local Geotechnical (Soils) Engineer for additional guidance and direction prior to pool installation. 3. Wall panel backfill materials shall consist of clean porous soils, free of roots and debris, installed and carefully tamped to eliminate voids, in layers not exceeding 12" thick. In addition, backfill materials shall not exceed the same equivalent fluid pressure characteristics identified in Item 2 above. Lastly, backfilling operations behind the pool panels must be performed in conjunction with the pool filling operations. Although these calculations show that backfill material can be placed behind the pool panels when the pool is empty, these pool panels should not be considered capable of independently withstanding either the pool water's lateral forces or the lateral soil forces (from behind the pool panels). 4. The pool is designed to remain full of water at all times. The pool may be damaged if the water level is allowed to drop below the pool inlet. When appreciable drawdown is noticed or if it becomes necessary to drain the pool, contact Technican Pacific Pools, Inc. or its agent immediately for instructions. Temporary shoring of the pool panels is highly recommended. 5. These structural calculations shall be considered void if not complete (pages 1 - 13) and do not contain a raised P.E. review seal, signature, and color watermark on each page. 6. Pool system is not designed for earthquake or surcharge loading (i.e., neighboring structures, vehicles, trees, equipment, etc.). 7. Finished decks and/or grades shall be constructed in accordance with the pool manufacturer's guidelines and be sloped away from the pool copings at a rate of not less than 1/4" per foot. 8. Concrete bond beam dimensions shall be 10" x 2'-0" minimum. 9. These calculations are in compliance with the following state and national codes: 1. 2000 thru 2006 Nationally accepted International Building Code (IBC) 2. 1999 Building Officials & Code Administrators (BOCA) 3. 1999 Standard Building Code (SBCCI) 4. 1997 Uniform Building Code (UBC) 10. Refer to the Pool Manufacture's "6 `st0ll ib`ri Manual for additional restrictions, requirements, guidelines, and recommendations. Void -without -signature, raise. - - and color watermark. Not for use in Master�Pe' • • pli. r ions. Issue No. 28-5735 Expiration Date: 6/19/Q9=0iIy For Installation Address: Tim Parker, 14222 E Crown, Spokane Valley WA 99216 Schafer Engineering Associates 13of13 BOLT BOLT ED [�C-AFS - (SUPPLIED WITH CLASSIC ST.J'EL ALL ICI TS)TWO COMPONENT PANEL BRACE C-SHORT A -FRAME F- LONG AFRAME ARM TWO COMPONENTS ARE BOLTED TOGTHER AND TO THE POOL PANELTO FORM A STRONG NON-ADJUSTABLE PANEL BRACE. THE UNIT IS ATTACHABLE TO PANEL JOINTS AND PANEL RIBS. COMPONENTS ARE MADE FROM 14 GAUGE Z-700 GALVANIZED STEEL RECOMMENDED APPLICATION TO PANEL JOINTS ONLY. (ATTACHES WITH 3 BOLTS) CAN BE USED WITH STANDARD DECK SUPPORTS (IPC-DSS) AND 30" DECK SUPPORTS (IPC-DSS30) DOI T 1t1B,Ut STAKG STRUCTURAL P.E. REVIEW SEAL VOID WITHOUT SIGNATURE AND RAISED SEAL NOT FOR USE IN MASTER PERMIT APPLICATIONS ?,'' ISSUE#: 28-5735 DATE: 02/28/08 EXPIRATION DATE: 06/19/09 SEAL IS APPLICABLE FOR: Tim PARKER 14222 E Crown Spokane Valley, WA 99216 STRUCTURALLY COMPLIANT WITH THE BOCA (1999); SBCCI (1999), UBC (1997), NSPI-5 (1995) AND NATIONALLY ACCEPTED IBC/IRC (2000 thru 2006) CODES f -FRAMES LOCATED AT PA?* _L JO WTS AS Si+DI M 4' 16' 8' 4' tech nlcan 'CODE: ISK-RE-1632-0S-STD CUSTOMER: LEISURE-SPOKANE DATE: 42128r08 D 08LS-0258 9D' 90' 8 3' 4" 1 4' -8" 8-0"S K 8'-0"RT 1 8'-0hl 8'-0" 8'-0" 8'-0„ 8'-0"RT 8'-0" 9O' 0 TYP 2 FL M 90' 9'J' .2,NGLE BRACE WITH 6' 21SERTS TiP 4 Pi. 4' 6' AYERACE WATER LEt L 14' 32' 8' 16-0 X 32-0 RECTANGLE-6IN. RAD TAG NAME: 'r" S.O.# STEP: ST99-9S-S T P RECIRC HAYWARD 1086 VOLUME (US GAL): 17,859 feet Furst PERIMETER: 104'-0° AREA (SQ.: T_): 544 LINER AREA (SQ,FT.): 512 ONelsiDIJ.S. 21F'1, VT ��ulaE cEsr,m:112 ?xusiwf SHALL EE 1451750L9 el ,H_E'M H o,+»56LITh1 B aatifl Oar iwuF�.Ltt' po2Rs 5PECF:4Tzw .RE c h-rArr orrpliir cualUi'ztr WaMIFAGIlRER f�-iYrEN F1r2T1D,L4. MEETS DEPTH AND SHAPE MINIMUM STANDARD ANSIJN'SPI5-2003 DRAWN BY: J. CUMMERSON J w 0) —I w (/)5 w Z a Ce w� aQ qJ Z LL U) U� p co �o u. 5 I— >o Z Z 0 H U J a a ce w a w H Z w 0 m 0 0 a w 0 O 0 SFTY COVER AREA (SO.FT.): 612 r SHEET: 1 OF 2 UTAEiUNALS A —8 o K I H1 H2 SI 52 A e c o 1 2'-10" 38'-0 3/4" 42'-0 112" 18'-1 1/4' 2 34'-0 314' 6'-4" 18'-11 314" 38'-5 3/4" 3 34'-6 8'-5 3/4' 1 S-2 3I4" 36'-9 1/4" 4 38'-9 1/4' 15'-2 3/4' 8'-5 314' 34'-6 114" 5 38'-5 3/4" 18--i i 3/4' 6'-4` 34'-0 314" 6 18'-1114' 42'-01/2' ' 38'-03/4- 2'-10" Si 26'-1" 14'-13/4' 22'-93/4" 31'-71/2' 52 31'-71/2' 2T-9314" 14'-1314' 26'-1- Hi 1 12'-2' 28'-0 3/4" 33'-3 1/2" 21-7 1 /2' H{2 [ 21'-7 1/2' , 33.3112" 28'-0 3/4' 12'-2' ' A - 40'-0" , 44'-8 3/4" 20'-0' 3 4 c r • 1 TO 21 32'-0" 1 TO 3 32'-3" 1 TO 4 34'-2" 1 TO 5 35'-9 1!4 1 TO 6 I 16'-0' 1 TO S1 1 TO S2 1 TO HI L 28'-101/4" 10'-0' 1 TO H2 2 TO 3 2 TO 4 2 TO 5 2 TO 6 2 TO Si 2TOS2 2T0H1 2 TO H2 3 TO 4 3 TO 5 3 TO 6 3TOS1 3 TO S2 3TOH1 3TOH2 4 TO 5 4 TO 6 4 TO S1 4 TO S2 4 TO HI 4 TO H2 5 TO 6 18'-10 1/2" 4'-0" 12'-0" 16'-0' 35-9 1/4" 8'-0" 1T-ID 314" Z7'-21/2" 8'-0^ 12'-0" 8'-11 1/4" 14'-5' 22'-4 1/4' 25'-0 314" 4'-0" 32'-3" 8'-11 114" 25-0 314' J 22`41/4' 32 -0. 5TOS1 1T-10 3/4" 5TOS2 8'-0" 5 TO H1 5 TO H2 6TOS1 6 TO S2 6TOH1 6TOH2 Si TO S2 S 1 TO H1 Si TO H2 S2 TO H1 S2TOH2 H1 TO H2 27 -2112° 1 22'-0" 28'-10 114" 24'-0" 18'-10 1 /2° 10'-0' 16'-0" 14.-0' 21'-3" 21'-3" 14'-0" 16'-0" tectnican POOL PRODUCTS 16-0 X 32-0 RECTANGLE-6IN RAD '°wG08LS-0258 DATE: 02/28/08 SHEET: 2 OF 2 CITY COPY TH RUILDINGSUP !r:rsT T. L.) 1NSPEC 11C, ley REVIEWED FOR CODE Cr•MPLIANE:F. SPOKANE VALLEY '111/t_ 3