2015, 02-11 Permit App BLD-2015-0250 AdditionSpokane
Valley
Community Development Department
Permit Center
11703 East Sprague Avenue, Suite B-3
Spokane Valley, WA 99206
Tel: (509) 720-5240
Fax: (509) 688-0037
permitcenterc spokanevalley.org
(Staff Use Only)
PERMIT NUMBER:
PERMIT FEE:
RESIDENTIAL CONSTRUCTION PERMIT APPLICATION
❑ NEW CONSTRUCTION ❑ ADDITION/REMODEL ❑ ACCESSORY BUILDING
❑ OTHER
❑ DECK
SITE ADDRESS:
Project #V-Di j5 COS
ASSESSORS PARCEL NO.: LEGAL DESCRIPTION.:E
OWNER/APPLICANT (CHECK BOX, IF MAIN CONTACT ❑�:
C E i V E D
NAME: KEN GROH
I,
ADDRESS:1416S. DAVIDST
CSV PFRMIT-'NT`�f�
CITY: SPOKANE VALLEY
C Si'F(iTE:WVA 1 REV i
•
PHONE: 5092201904
FAX:
EMAIL:KENBG@ROSAUERS.COM
CONTACT NAME: KEN GROH
PHONE:5092201904 FAX:
EMAIL:
CONTRACTOR NAME (CHECK BOX, IF MAIN CONTACT ❑):
MAILING ADDRESS:
CITY:
STATE: ZIP:
PHONE:
FAX: EMAIL:
CONTRACTOR LICENSE No.:
EXPIRES: CITY BUSINESS LICENSE NO.:
DESCRIBE THE SCOPE OF WORK IN DETAIL AND INDICATE USE & PROPOSED USE:
EXPANDING HOUSE APPROX 60 SQ ST, ADDING WALKIN CLOSET
****YOU MUST COMPLETE THE FOLLOWING****
MARK N/A IF NOT APPLICABLE
Height to Peak:
Dimensions:
No. of Stories:
Total Habitable
Space:
Main Floor SQ FT:
Upper Floor SQ FT:
Unfinished Basement SQ
FT:
Finished Basement SQ
FT:
Garage SQ FT:
Deck/Covered Patio SQ
FT:
Impervious Surface
Area:
30% Slopes on
Property:
No. of Bedrooms:
Construction Type:
Heat Source:
Sewer or Septic:
TOTAL COST OF PROJECT: $
DISCLAIMER
The permitted verifies, acknowledges and agrees by their signature that: 1) if this permit is for construction or on a dwelling, the dwelling
is/will be served by potable water. 2) Ownership of this City of Spokane Valley permit inure to the property owner. 3) The signatory is the
property owner or has permission to represent the property owner in this transaction. 4) All construction is to be done in full compliance
with the City of Spokane Valley Development code. Referenced codes are available for review at the City of Spokane Valley Permit Center. 5)
The City of Spokane Valley permit is not a permit or approval for any violation of federal, state or local laws, codes or ordinances. 6) Plans
or additional information may be required to be submitted and subsequently approved before this application can be processed.
Signature )(
Date:2-11-15
PLANNING
4,TE:
fJO
DEPT. AP
•
N I
N
Pr
ject
RECEIVE
FEB 1 1 2015
CSV PERMIT CEN
S4 #1 1 REV.
63C).)7/ /lEsiaervicez
3L
ER
r-
P►r 2I7 or) o& P(oo)
UoregMTep
O Li " }r/ 5t�
• R _ a 1.0a1.15
R- 30 ; `loa r-.
• 41F S AK&ear
0,0.
7f
0
r,.
..F, ....... K
LIH
City of
SPOKANE VALLEY BUILDING DEPARTMENT
11707 E. Sprague Avenue #106, Spokane Valley, Washington 99206 - Tel 509-688-0036 - Fax 509-688-0037
Following is a typical cross-section for a residential garage. It may not represent the proposed project. If you are using this detail
as a portion of your plan submittal, please complete the requested information in the boxes provided on both sides of this sheet
This completed sheet, along with any additional information needs to be submitted with your apllication and be on site at the time
of inspection.
PROTECTION AND OPENINGS BETWEEN
DWELLINGS AND PRIVATE GARAGES SHALL HAVE:
1) MATERIALS APPROVED FOR ONE HOUR FIRE
RESISTIVE CONSTRUCTION ON THE GARAGE SIDE:
" 5/8" TYPE "X GYP BOARD (HABITABLE SPACE ABOVE)
* 1/2" GYP BOARD (RESIDENCE/ATTIC, FLOOR/CEILING)
2) OPENINGS BETWEEN GARAGE AND RESIDENCE
SHALL BE EQUIPPED WITH SOLID WOOD DOOR, SOLID OR
HONEYCOMB CORE STEEL DOORS NOT LESS THAN 1 3/8",
OR 20 MINUTE FIRE RATED DOORS.
ALTERNATE FOUNDATION FOR
ACCESSORY BUILDINGS FROM
400 SQ. FT. TO 3000 SQ. FT.
(2)#4 REBAR
SECTION A —A
--12"---1
24" MI
NOTE:
Diagonal wall bracing required on
each comer and every 25 feet of wall.
Walls within 3 feet of a property line or
within 6 feet of a dwelling must be 1 hour
rated. (5/8" type "X" gypsum sheathing
on both sides of wall). Openings are not
permitted in these walls. Garages over
3,000 sq. ft. require protection when
closer than 20 feet to the property line.
Parapets may be required.
ENGINEERED TRUSS OR
RAFTSIZAND SPACING
x C) O.C.
J3 Y6 I( ROOFING MATERIAL
3 get 7:-(' ROOFING PAPER
/LYwl Y6 ROOF
SHEATHING
SOLID BLOCKING
BETWEEN.TRUSSES
N.
WALL SHEATHING—"
l'1 (1J i IDING
6' MIN.
24" MIN.
DOUBLE TOP PLATE
WALL HEIGHT I 0
PRESSURE TREATED
SOLE PLATE
3-1/2" CONCRETE SLAB
6"x12"
FOOTING
ANCHOR BOLTS
1/2"x9" MIN.
(7" INTO CONCRETE)
6' O. C. OR APPROVED
ANCHOR INSTALLED
PER MANUFACTURER.
FOUNDATION PLAN
PLEASE COMPLETE THE FOLLOWING INFORMATION AND ADD ON THE DRAWING BELOW.
BUILDING DIMENSIONS:
GARAGE OPENING AND HEADER SIZE:
INDICATE THE LOCATION AND SIZE OF ALL WINDOWS AND DOORS ON THE PLAN.
0
z
W
-J
WIDTH
L_
Please note that while every effort is made to assure the accuracy of the information contained in this brochure is
not warranted for accuracy. This document is not intended to address all aspects or regulatory requirements for a
project and should serve as a starting point for your investigation. For detailed information on a particular project,
permit, or code requirement refer directly to applicable file and/or code/regulatory documents or contact the
appropriate division.
r—I
10h?1oga
aI ley
FOR CODE COMPLIA
Y