Loading...
1998, 11-09 Permit App 98011353 Storage Bldg Project Number: 98011353 Inv: 1 Application Date: 11/9/98 Page 1 of 2 THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Project Information: >,,:A K:;Y;YYYYYYYYYYY.Y YYYYYYY;YY YYYYY;:>»>:YYY:YY:YY:YYYY:YYY YYYY YYYYYYY.,;Y wY: YYYYY.< YYYY<Y.YY YYYY. Permit Use: STORAGE BUILDING 24 X 38 Contact: MOMB BUILDINGS Address: P.O.BOX 190 Setbacks:Front 50+ Left: 10 Right: 156 Rear: 10 C-S-Z NEWMAN LAKE WA 99025 Phone: (509)921-5655 Site Information: ::.::..:.......::::.:...:•.:::::::::, ............ ..::. ...........v::.:..., :;<.: ...... ...... Plat Key: 002089 Name: PONDEROSA ACRES 6TH ADD District: F Parcel Number: 45324.0909 SiteAddress: 4225 S DRIFTWOOD DR Owner:Name: RAMPLEY,LEI: SPOKANE,WA 99206 Address: 4225 S DRIFTWOOD DR Location::SPO SPOKANE,WA 99206 Zoning: UR 3.5 Urban Residential 3.5 Water District: Hold: ❑ Area: 48,000 Sq Ft Width: 190 Depth: 252 Right Of w r (ft): 0 Nbr of Bldgs: 100 Nbr of Dwellings: 1 Review Information: :\y } :':'y{t: �iMen 4>SkY� h4�: �:?{is:Y{ tl ,\ �? 6hU�rti}\Y.iN� 4::.. Y {:.;.... .......i'S.v.��{•:.v'L.?i......:J+4 Department Review BUILDING Site Plan Review Comments: R ,LS( tlfij f8/ BUILDING Plan Review Comments: ..26?C I/ Ate HEALTHDISTRICT Septic System Review —�— _ Comments: Olf�1 Pc rmits. {: {•isi•: ii isiiiiLii,+FLii:<.:.i:::i'•iFi: {i•%L{ii{{h:4:{ gp:•is:•ii:oi:•••:iii{\\4{•:i•:titii•:,. •. :Y{K{bi:: { 3tSkY3i�ffi i£:::';:YYSi:;:;>:;;::+Y•::{.;,v.::•: ..::�i:;:r::rF::?�:Y:;:.................Y......................................:�f6�>�fS9k.VX�3?PFf�>fdAs'6Rh�:.......... :.,.:_:;<•.P4Y�.s`if?Y.#rokt'i3t# Project Number: 98011353 Inv: 1 Application Date: 11/9/98 Page 2 of 2 THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Building Permit Contractor: UNKNOWN Firm: UNKNOWN Address: UNKNOWN Phone: (000)000-0000 UNKNOWN,WA UNKNOWN Building Characteristics Const Category: New Nbr Of Dwellings: 1 Occupant Load: 0 Building Height: 13 Stories: 1 Bldg W x D: 24 x 38 Building Sq Ft: 912 Sprinklers: ❑ Req Parking: 0 Handicap Parking: 0 Critical Materials: ❑ This Application: Total Project: Description Grp Type Notes Sq Ft Valuation Sq Ft Valuation GARAGE U-1 VN 912 $10,944.00 912 $10,944.00 Totals: 912 $10,944.00 912 $10,944.00 Item Description Units Unit Desc Fee Amount RESIDENTIAL VALUATION 1 Y OR BLANK $175.50 STATE SURCHARGE 1 Y OR BLANK $4.50 RESIDENTIAL SURCHARGE 1 Y OR BLANK $38.61 Permit Total Fees: $218.61 Payment umma »,.. :.r..<, ::£;:...>,,...,,................,......:»>,............. ,,,,,.....,...........;:. Summary: :>,2:Go,�s.:2.,>_.'iCC..3...\.:.,>,>.:.w,t ....»».vi>....,�3 .„„„..r ,,. Operator: RMB Printed By: RMB Print Date: 11/9/98 Permit Type Fee Amount Invoice Amount Amount Paid Amount Owing Building Permit $218.61 $218.61 $0.00 $218.61 $218.61 $218.61 $0.00 $218.61 NOV-05-98 THU 03:23 PM ENGINEERING TECH SRVS FAX NO. 605 335 7776 P. 01 11/o5/98 11:38 1T5o9 921 5969 Non STEEL BLDG 12091 Post Frame Building Schedules Prepared For: Lee Rampley Design per 1997 USC 4225 Driftwood Drive Seismic Zone: 2B Spokane Spokane County, WA Building Span : 24' Roof Load ( Snow ) : 30 psf Building Length : 38' Roof Dead Load : 3.3 psf Eave Height : 10' Ceiling Dead Load : 1 psf Roof Pitch : 3/12 Wind Load : 75 mph Exposure B Average Roof Height: 11'6" Soil : 2000 / 200 Enclosed Structure NOTE : Huiiding is designed to support 1' 6" overhangs on all sides Front Sidewall Column Spacing :2'.3.5"-9'8.5"-2'2.5"-917"-2'2.5"-9'6.5"-2'3.5" NOTE : Overhead Doors in BOTH 9' 8.5" and 9'7" bays Sidawall Column Grade : 6 x 4 Rough Hem-Fir #2 Column Depth : 31" ( Minimum ) Column Hole Diameter : 15" ( Minimum ) Minimum Endwall Steel : 6'1.3" NOTE : Requires a Concrete Floor -- See DTL 1/A-2 Endwall Column. Spacing : 12'-8'2"--3'10" ( front ) NOTE : Entry Door in 3'10" bay NOTE : 4-1/8"x4-1/8" Rough Hem-Fir(N) ; ?./;;2 at left of entry door : 12' ( rear ) Endwall Column Grade 6 x 4 Rough Hem-Fir f2 Ridge Purlins/Fascia Board : 2 x 5 M-10 1.2E MIL Wall Girts ( 20-1/2" BETWEEN ) : 2 x 4 2100f-1.6E MSR ( 2'3.5" bays ) ( 19-1/2" BETWEEN ) : 2 x 5 M-10 1.2E MEL ( 12' bays ) ( 19-1/2" BETWEEN ) : 2 x 5 M-19 1.6E MEL ( 14' bays ) Wall Girts To Columns 3 - 10d commons Roof Purlins/Save Girts : 2 x 6 1650f--1.5E MSR e 24" oc ( 14' bays ) : 2 x 5 M-19 1.6E MEL @ 24" oc ( 12' bays ) Interior Truss to Column_ : 2 - SOd Threaded Hardened Endwall Truss to Corner Column 6 -- 10d commons 2x6x16.5" End Truss Bearing Block : 31 - I0d commons WARNING : Added insulation, ceiling materials, lighting and HVAC equipment or other loads imposed upon the root system BEYOND those stated above will reduce the overall capacity of the structure and its ability to resist the required design snow loads. tf . ;),„;0 N.V.Ar.;141 I I lb 4.7 • onsAiro,fail. r �, a 4 - This site plan is being submitted for the pure obtaining a building permit and is a true and representation of the proposal. Ail known prc lines/dimensions, curb lines, structures and ea: have been identified. Also indicated are weM bodies of wastee slopes or other critical Sitof;ed: - — 'G .att': V 1// V q F ml ADDRESSS ZONE 0=- ,S ROAD WIDTH 5� s FRONT_�o- FLANKING COMMENTS REVIEWED BY