Loading...
2013, 10-17 Permit App BLD-2013-2141 Egress Window, ReroofCommunity Development Department Permit Center crry oe 11703 East Sprague Avenue, Suite B-3 Spokane Spokane Valley, 99206 Tel: (509) 688-00303 6 ®=valley- Fax: (509) 688-0037 nPrmitcenter0sooka nevaliev. oro (Staff Use Only) PERMIT NUMBER: PERMIT FEE: 3�-b RESIDENTIAL CONSTRUCTION PERMIT APPLICATION Rl NEW CONSTRUCTION W ADDITION/ REMODEL R ACCESSORY BUILDING 11 DECK SITE ADDRESS: / O yz-0 MI OTHER ASSESSORS PARCEL NO.: LEGAL DESCRIPTION: 011TI nThrG n1aIMCD NAaAC- r D PHONE: - FAX: CELL: CONTACT NAME: PHONE: - FAR: n_ CONTRACTOR NAME:t v� 47 KQV%e\ % (-7 ' 1-%01A-<cM: 7r—z—) MAILING ADDRESS: /. ( Q 'IV: 9-- ' NTER DESCRIBE THE SCOPE OF WORK IN DETAIL AND INDICATE USE St PROPOSjED USE: ✓- ****YOU MUST COMPLETE THE FOLLOWING**** MARK N/A IF NOT APPLICABLE Height to Peak: Dimensions: No. of Stories: Total Habitable Space: Main Floor SQ FT: Upper Floor SQ FT: Unfinished Basement SQ Finished Basement SQ FT: FT: Garage SQ FT: Deck/Covered Patio SQ Impervious Surface 30% Slopes on FT: Area: Property: No. of Bedrooms: Construction Type. Heat Source: Sewer or Septic: TOTAL COST OF PROJECT:! DISCLAIMER . The permitted verifies, acknowledges and agrees by their signature that: 1) If this permit Is for construction or on a dwelling, the dwelling is/wlll be served by potable water. 2) Ownership of this City of Spokane Valley permit Inure to the property owner. 3) The signatory is the property owner or has permission to represent the property owner In this transaction. 4) All construction is to be done In full compliance with the City of Spokane Valley Development code. Referenced codes are available for review at the Qty of Spokane Valley Permit Center. 5) The Qty of Spokane Valley permit Is not a permit or approval for any violation of federal, state or local laws, codes or ordinances. 6) Plans or additional Information may be required to 4A submillted and subsequently approved before this application can be processed. Date: /0//?/"s Updated 1-11-11 Page 1 of 1 http://www.spokanevalley.org/fliestorage/124/938/210/948/1496/Building_PermI -_Residential i1-11-11.doc EMERGENCY ESCAPE AND RESCUE EGRESS WINDOW *Minimum 20" wide clear opening *Minimum 24" high clear opening *Minimum 5.7 sq ft openable area **5.0 sq ft minimum @ grade floor *Top of sill maximum of 44" above finished floor 20' CLEAR MIN i i i OPENABLE i' AREA 5.7 SO FT MIN x(5.0 SO FT MIN GRADE FLOOR) MINIMUM SIZE WINDOW FOR 20 IN. CLEAR WIDTH 4.14 CLEAR SILL HEIGHT 44' MAX it 2� .5 A e.F eo Uk icl4xn iD2 Cca�� i^¢o•c�ex c� �n �ec�wS MINIMUM SIZE WINDOW FOR 24 IN. CLEAR HEIGHT 1 24' CLEAR MIN I FLOOR Grade floor opening is a window or other openings located such that the sill height of the opening is not more than 44" above or below the finished ground level adjacent to the opening. WINDOW WELL *Minimum 36"x 36" *Minimum 9 sq ft clear floor area *Top of wall a maximum of 44" above the floor of the well *A guardrail is not required unless an exit way adjoins the well. *Provide drainage DEEP WELLS *If the top of the window well wall is more than 44" above the floor of the well, either a permanently fixed ladder or stair egress is required. *The ladder or stair may encroach a maximum of 6" into the required clear floor space. LADDER EGRESS *At least 12" in width *Rungs not more than 18" on center *Minimum 3" toe space *Permanently fixed *Non-combustible *Shall extend to top of wall LADDER OR STAIR PERMITTED NET CLEAR DIMENSIONS WHEN TO ENCROACH MAXIMUM OF FULLY OPENED TO PROVIDE 6 INCHES INTO REQUIRED 9 SQUARE FEET OF OPENING DIMENSIONS WINDOW WELL T\ LADDER OR STAIR REQUIRED \\\ 36' MIN /\A *Where bars, grills, covers, screens or similar devices are installed over emergency escape and rescue openings, they must be openable from the inside without the need of special knowledge or special tools, and the force to open them may not be greater than that required of the opening itself. FILE EMERGENCY ESCAPE OR RESCUE OPENING `\\ WITH FINISHED SILL ''/// HEIGHT BELOW ADJACENT GRADE *Where bars, grills, covers, screens or similar devices are installed over emergency escape and rescue openings, they must be openable from the inside without the need of special knowledge or special tools, and the force to open them may not be greater than that required of the opening itself. FILE