2007, 03-23 Permit 07001263 Approved PlansWSEC TABLE 6-2 PRESCRIPTIVE REQUIREMENTS°4 FOR GROUP R OCCUPANCY CLIMATE ZONE 2 Option Glazing % of floor Glazing U-Factor Doors Factor Ceiling2 Ce"rling3 WaII12 Abovera Wall? Below Grade Wall? Below Grade Floors Slabb on Grade Vertical Overhead" I. 10% 0.40 0.58 0.20 R-38 R-30 R-21 int' R-21 R-12 R-30 R-10 II. 15% 0.40 0.58 0.20 R-38 R-30 R-19+ R-58 R-21 R-12 R-30 R-10 III. 17% 0.37 0.58 0.20 R-38 R-30 R-19+ R-58 R-21 R-12 R-30 R-10 IV. 25% Group R-1 Occupancy Only 0.35 0.58 0.20 R-38 / U=0.031 R-30 / U=0.034 R-21 Intl / U=0.054 R-15 R-12 R-30 / U=0.029 R-10 / F=0.54 V. Unlimited Group R-3 Occupancy Only 0.35 0.58 0.20 R-38 R-30 R-21 int' R-21 R-12 R-30 R-10 VI. Unlimited Group R-1 Occupancy Only 0.32 0.58 0.20 R-38 / U=0.031 R-30 / U=0.034 R-21 int' / U=0.054 R-15 R-12 R-30 / U=0.029 R-10 / F=0.54 * Reference Case 0. Nominal R-values are for wood frame assemblies only or assemblies built in accordance with Section 601.1. 1. Minimum requirements for each option listed. For example, if a proposed design has a glazing ratio to the conditioned floor area of 13%, it shall comply with all of the requirements of the 15% glazing option (or higher). Proposed designs which cannot meet the specific requirements of a listed option above may calculate compliance by Chapters 4 or 5 of this Code. 2. Requirement applies to all ceilings except single rafter or joist vaulted ceilings. 3. Requirement applicable only to single rafter or joist vaulted ceilings. 4. Below grade walls shall be insulated either on the exterior to a minimum level of R-10, or on the interior to the same level as walls above grade. Exterior insulation installed on below grade walls shall be a water resistant material, manufactured for its intended use, and installed according to the manufacturer's specifications. See Section 602.2. 5. Floors over crawl spaces or exposed to ambient air conditions. 6. Required slab perimeter insulation shall be a water resistant material, manufactured for its intended use, and installed according to manufacturer's specifications. See Section 602.4. 7. Int. denotes standard framing 16 inches on center with headers insulated with a minimum of R-5 insulation. WSEC Builder's Field Guide 5th Edition COOPERATIVE EXTENSION WASHINGTON STATE UNIVERSITY ENERGY PROGRAM 1.7 BUILDING PLANNING R311.5.6.3 Handrail grip size. All required handrails shall be of one of the following types or provide equiva- lent graspability. 1. Type I. Handrails with a circular cross section shall have an outside diameter of at least 11/4 inches (32 min) and not greater than 2 inches (51 mm). If the handrail is not circular it shall have a perimeter di- mension of at least 4 inches (102 mm) and not greater than 61/4 inches (160 mm) with a maximum cross section of dimension of 21/4 inches(57 min). 2. Type II. Handrails with a perimeter greater than 61/4 inches (160 mm) shall provide a graspable finger re- cess area on both sides of the profile. The finger re- cess shall begin within a distance of 3/4 inch (19 mm) measured vertically from the tallest portion of the profile and achieve a depth of at least 5/16 inch (8 nun) within'/8 inch (22 min) below the widest por- tion of the profile. This required depth shall con- tinue for at least 3/8 inch (10 mm) to a level that is not less than 13/4 inches (45 mm) below the tallest por- tion of the profile. The minimum width of the hand- rail above the recess shall be 1'/4 inches (32 min) to a maximum of 23/4 inches (70 mm). Edges shall have a minimum radius of 0.01 inches (0.25 mm). R311.5.7 Illumination. All stairs shall be provided with il- lumination in accordance with Section R303.6. R311.5.8 Special stairways. Circular stairways, spiral stairways, winders and bulkhead enclosure stairways shall comply with all requirements of Section R311.5 except as specified below. R311.5.8.1 Spiral stairways. Spiral stairways are per- mitted, provided the minimum width shall be 26 inches (660 mm) with each tread having a 71/2-inches (190 mm) minimum tread depth at 12 inches from the narrower edge. All treads shall be identical, and the rise shall be no more than 91/2 inches (241 min). A minimum headroom of 6 feet 6 inches (1982 mm) shall be provided. R311.5.8.2 Bulkhead enclosure stairways. Stairways serving bulkhead enclosures, not part of the required building egress, providing access from the outside grade level to the basement shall be exempt from the require- ments of Sections R311.4.3 and R311.5 where the maxi- mum height from the basement finished floor level to grade adjacent to the stairway does not exceed 8 feet (2438 mm), and the grade level opening to the stairway is covered by a bulkhead enclosure with hinged doors or other approved means. R311.6 Ramps. R311.6.1 Maximum slope. Ramps shall have a maximum slope of one unit vertical in eight units horizontal (12.5-per- cent slope). R311.6.2 Landings required. A minimum 3-foot-by-3-foot (914 mm by 914 mm) landing shall be provided: 1. At the top and bottom of ramps, 2. Where doors open onto ramps, 3. Where ramps change direction. R311.6.3 Handrails required. Handrails shall be provided on at least one side of all ramps exceeding a slope of one unit vertical in 12 units horizontal (8.33-percent slope). R311.6.3.1 Height. Handrail height, measured above the finished surface of the ramp slope, shall be not less than 34 inches (864 mm) and not more than 38 inches (965 mm). R311.6.3.2 Handrail grip size. Handrails on ramps shall comply with Section R311.5.6.3. R311.6.3.3 Continuity. Handrails where required on ramps shall be continuous for the full length of the ramp. Handrail ends shall be returned or shall terminate in newel posts or safety terminals. Handrails adjacent to a wall shall have a space of not less than 1.5 inches (38 mm) between the wall and the handrails. SECTION R312 GUARDS R312.1 Guards required. Porches, balconies or raised floor surfaces located more than 30 inches (762 mm) above the floor or grade below shall have guards not less than 36 inches (914 mm) in height. Open sides of stairs with a total rise of more than 30 inches (762 min) above the floor or grade below shall have guards not less than 34 inches (864 min) in height measured vertically from the nosing of the treads. Porches and decks which are enclosed with insect screening shall be provided with guards where the walking surface is lo- cated more than 30 inches (762 mm) above the floor or grade below. R312.2 Guard opening limitations. Required guards on open sides of stairways, raised floor areas, balconies and porches shall have intermediate rails or ornamental closures which do not allow passage of a sphere 4 inches (102mm) or more in di- ameter. Exceptions: 1. The triangular openings formed by the riser, tread and bottom rail of a guard at the open side of a stairway are permitted to be of such a size that a sphere 6 inches (152 mm) cannot pass through. 2. Openings for required guards on the sides of stair treads shall not allow a sphere 4 3/8 inches (107 mm) to pass through. R311.6.3.3 Continuity. Handrails where required on ramps shall be continuous for the full length of the ramp. Handrail ends chall be returned or shall terminate in newel posts or safety. terminals. Handrails adjacent to a wall shall have a space of not less than 1.5 inches (38 min) between the wall and the handrails. At least one handrail shall extend in the direction of ramp run not less than 12 inches (305 min) horizontally beyond the top and bottom of the ramp runs. 2003 INTERNATIONAL RESIDENTIAL CODE® STANDARD BLUEPRINT U L 16 12/87 UPC 508.2 — Water heaters require anchoring or strapping at upper and lower one third points to prevent horizontal displacement during earthquakes. Strapping shall be a minimum of 4 inches above controls. LANDING required on both sides of exit doors with min. size of 3 ft. measured in direction of travel by 3 ft. or width of door if greater, and not lower than 1 '/Z in. below threshold. Landing required at other exterior doors is a minimum size of 3 ft travel distance by width of door, and not lower than 7 3/4 in. below threshold provided the door does not swing over the landing. 179072 ZZ 7 v ._ . - :L:GT_:"PINL. htew AC72 ir. ►opt • u di P30,TF4- gm. f.— p 4- KJ 17o Egress windows openable 5.7 sq. ft. - 44" sill n 5.17: / I• o l�1 rye C3i2e:AtJ1.. Egress windows openable 5.7 sq. ft. - 44" sill z . zx to (ems.. 4-11 }el'7{ZQQ ►r-i- .._ Egress windows openable 5.7 sq. ft. - 44" sill 1._!, 5.41.C.174g--,AVer, S e� 4 o"::.ice I1'-g„ 1r :Itsit• G—► tZi�'! t:-: z lam::tR't:.. • • : F \ex.es TL• 41.--11, 4,1 ..7: s'. ' ;; • v zt- J -�' tit V :.A217r ..t Ot4. eTZC L7 I..1o4S• .:.c.2V.12 N Ar C EMERGENCY EGRESS REOUIREMENTS FROM SLEEPING ROOMS 1) NET CLEAR OPENING: 5.7 SQUARE FEET GRADE FLOOR OPENING (MAX 44") 5.0 SQUARE FEET 2) NET CLEAR OPENING HEIGHT `' 24INCHES 3) NET CLEAR OPENING MOTH 2OINCHES 4) MAX FINISHED SILL HEIGHT 44" ABOVE FLOOR 51 EMERGENCY ESCAPE & RESCUE OPENING SHALLBE RATIONAL FM THE INSIDE OF THE ROOM WITHOUT THE USE OF KEYS ROOR TOOLS WHEN INTERIOR ALTERATIONS, REPAIRS OR ADDITIONS REQUIRING A PERMIT OCCUR, OR WHEN ONE OR MORE SLEEPING ROOMS ARE ADDED OR CREATED IN EXISTING DWELLINGS. THE DWELLING UNIT SHALL BE PROVIDED WITH SMOKE ALARMS LOCATED AS REQUIRED FOR NEW DWELLINGS. SMOKE ALARMS SHALL. BE INTERCON- NECTED AND HARD WIRED IN SUCH A MANNER THAT THE ACTIVATION ,OF ONE ALARM WILL ACTIVATE ALL ALARMS. (BEDROOMS, AREAS APPROACHING BEDROOMS, VAULTED CEILING WITH RISE OF 24" & ON EACH FLOOR) EXHAUST FANS 100 CFM kitelien 50 CFM bathrooms & laundry 'i ataT To EYE- AteA. 'Sa :.!.i Minimum depth for frost protection in the City of Spokane Valley is 24 inches measured from the bottom of the footing to finish grade. Grade slope away from building a minimum 6 inches in first 10 feet. Radon Mitigation System Required If Vents Subject to Closure 6 mil Vapor Barrier Required ) • 12• , Ho K. r Anchor Bolts- Minimum Y2" x 10" with 7" concrete embedment at 6' o.c. and 12" from ends of sill plates. U N4t7'-AT' 1 0 L1 Wry' LApPeR., Min. 4 ft Brace Wall Panel per R602.10.3 & R602.10.4 Min. 2 ft 8 in. Alternate Brace Wall Panel per R602.10.6 Min. 16, 18 or 20 in. APA Portal Frame Bracing Engineered Shear Wall Bracing 4- .XQ.&tom r„r Under floor Clearance 18" 1 MT, ... FOcLN 1 : 'C7ei . 3 1 r tr_XtT,. 2'ES_410 5' ff1 . LO_T- tp- fizi‘Nocep... ,.4i _ et-L� WWc' TH LEV-r t 1.1 (7" Le v4-1-10 STAIRWAYS: Minimum width 36 in. with min. tread run of 10 in., max. rise of 7 3/4 in. & nosing of 34 1 V4 in. Min. 6 ft. 8 in. headroom. Enclosed usable space under stairways requires 1 hour fire protection of Y2 in. GWB HANDRAILS: Height of 34 - 38 inches when required by four or more risers shall be continuous the full length of stairs with the ends returned or rounded. LANDINGS: Required min. width of 36 in. or width of stairway and 36 in. travel distance 5 E-E -1\TT-Atc-i-cmte-T- tgAme-5 DECKS: Ledger board requires 1/2" lag bolt (aj 16" o.c. with flashing behind. Guardrail 36 in. high required if floor more than 30 in. above grade. Picket spacing no more than 4 in. apart. Posts require approved base and beam connectors. Min. 24 in. frost protection to finish grade with min. 12 in. footing base. 17'14 I INSAA;=;.7 / 0 r?* I -eh- V47 is45TALL.::::Va7 7.14 Co 'Sr r4,11Ett, '31 irc2C2F OvAr441-1AnIti Nsw ty,4,e,t al:4*d f•z-.."49A1-1,44i: 2-1 2 FidAvkike,k 3 G.. •ooa-s /.1 7 ArLU-Noi Cd\q t-ry 2, ?TT gt.t. 0 r X 1--)C (Iteat-S 'DO iv-6-r A Lk-0,J) CAAI tv,./ r&o-- f(k30 "1"-Y,3 ?LAN I=P IELe2e7 oVeiZi-Lets.ists., NSW -VIC ..ec2144** WALL. • 1..te et:A. 4- f .r.4,=••••••••.•]••••••••4111 -Z.X.4- t " e. 140 _ rNL.Nr4AL..4. Alskit*,47/".1-9ds.• rye? 12-‘4,PZ.1 JEw T.X10 1.4sii!ci‘ \0•.nrf247" E)<1.*: 12.T. VAR:31Z-. • . •••C•tatIMMOVZIONSMMXIM me.m, 12C2LqP INV-1 =to C-111- • OVESIZ 'HW p.40,c3•' . 1 4S1.4 SCP u g.ArE N1101.3.1 - Attic insulation certification required as to R — value or coverage. Markers, attached to trusses or rafters, required for every 300 sf of attic space with 1 inch high numbers for installed thickness of insulation. " ..•••Ice.g4N.CS.039r vwrie-do-te;x_ — PULL -T1-41 CAG t4SL11.- 1.L1-Aar E-C2 4z-x-4 tar; 0/e., w • cc 179072 0 a It mes CD O. W PROVIDE DIAGRAMS AND ENGINEERING LAYOUTS FOR ROOF TRUSSES, BEAMS AND FLOOR SYSTEMS PRIOR TO FRAMING INSPECTIONS CITY C s PY THIS BUILDING SUBJECT TO I^IELD INSPECTION CORRECTIONS REVIEWED FOR COr, COMPLIANCE SPOKANE VALLEY B :ILONG !VISION