Loading...
2007, 06-12 Permit App 07002236 RemodelSite Information: Plat Key: Name: Range District: Sout Project Number: 07002236 Inv: 1 Application THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Project Information: Date: 6/12/2007 Page 1 of 2 Permit Use: REMODEL HOME INTERIOR/ 2 EGRESS Contact: ELCON CONSTRUCTION WINDOWS Address: PO BOX 13037 C - S - Z: SPOKANE WA 99213-3037 Setbacks: Front Left: Right: Rear: Phone: (509) 926-8366 Group Name: Project Name: Parcel Number: 35231.1111 Block: SiteAddress: 520 S FANCHER RD Location:: CSV Lot: Owner: Name: ELLINGWOOD, RICHARD & DIA Address: 7715 E SKYLINE DR SPOKANE, WA 99212-3084 Zoning: UR-7 Urban Residential-7 Water District: 100 SPO CO WATER DIST#3A Area: 1.87 Acres Width: 0 Nbr of Bldgs: 0 Nbr of Dwellings: 0 Review Information: Hold: ❑ Depth: 0 Right Of Way (ft): 0 Review Building Plan Review Permits: mix. Released By: Originally Released: 6/12/2007 By: TMELBOU Contractor: ELCON CONSTRUCTION INC Address: 7715 E SKYLINE DR SPOKANE WA 99212 Building Permit Firm: ELCON CONSTRUCTION INC Phone: (509) 926-8366 This Application: Total Project: Description Gar Tyue Notes Sul Ft Valuation So Ft Valuation 1&2 FAMILY R-3 VB REMODEL/ 0 $16,000.00 0 $16,000.00 2 EGRESS Totals: 0 $16,000.00 0 $16,000.00 Item Description Units Unit Desc Fee Amount RESIDENTIAL PERMIT FEE 1 SELECT $265.25 WSBC SURCHARGE 1 SELECT $4.50 SF PLNS RVW < 7999 SQ FT 1 SELECT $106.10 Permit Total Fees: $375.85 Operator: JD Printed By: JD Print Date: 6/12/2007 Project Number: 07002236 Inv: I Application THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Date: 6/12/2007 Page 2 of 2 Notes: Construction within the setback is approved as legally non -conforming. Structure is located in the same place as recently demolished structure and is smaller than previous structure. New structure is OK as located- no increase in the non-conformance. Payment Summary: Permit Type Building Permit ffirkiZt=,r,O,a,,;1u. ���.a ..... Fee Amount Invoice Amount Amount Paid Amount Owing $375.85 $375.85 $0.00 $375.85 $375.85 $375.85 $0.00 $375.85 Disclaimer: Submittal of this application certifies the owner (or person(s) authorized by the owner) has both examined and finds the information contained within to be true and correct, and agrees that all provisions of laws and/or regulations governing this type of work will be complied with. Subsequent issuance of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the code or of any other state or local laws or ordinances. Signature: Operator: JD Printed By: JD Print Date: 6/12/2007 DEC E Community Development Residential Construction Permit Application Permit Center 11703 E Sprague Ave, Suite B-3 t Spokane Valley, WA 99206 (509)688-0036 FAX: (509)688-0 www.spokaneval le% .org 7 1, _ New Construction K.Addit9 n Other: PERMIT NUMBER: PERMIT FEE: "7(5-q Accessory Bldg Deck SITE ADDRESS: ASSESSORS PARCEL NO: 35-2-3 1 • (1 < I R. . � 5Pa1&6wQ ValLy wA c cp q _ LEGAL DESCRIPTION: L 1 f i f L s 7 48 ((t{ ti E L,S'ik. A 4-.4 ; t.� .• Building Owner: Name: R:. .-1 ti 0;..t&e ait :Thl w o Address:7 ...jug C . Sky l"tie OT . City: 5pd k4Ae_ Vail Ay State: WA Zip:ert-tZ Phone: 11_1_- Oy 80 Fax: N/jt Contact Person Name: (EA ;-tswdi-mBrt. Phone: S0 Z -`fzz - O''180 Describe the scope of work in detail: tie�•A1e1 l ( ,mtr en.r. 1-1e-144e N42-4a S)..`i Contractor: Name: (y4e o-t. e- -& f r...- -F s,n. ,L v., e- , Address: (a. '(far. ti'3 c,37 City:Se.LK kicL R..Y State: t,,t,jik Zip:-13 Phone: eju . glee Fax: 89 4) y 8 ContractorI i9'i<<,..1 Exp Date: —4/ d /zco9 City Business Lic. No: t_l.c.pNC1 992 ct) 6o306 Cost of project: $ 1 6, ep41r,..� sl. to uc,. 1 F�e�„q 1.-Le....)1�(: t<I�e.t Cc.b:K.e�J � �1 tb:1Rt 4 SI. are jeio i3s.i!ew. el (eploe.eL '- `-.3ti^d•,0S Proposed Use: et..LL as. Z c.e. **************The following MUST be complete: (write N/A if not applicable)********************** HEIGHT TO PEAK: 1y' DIMENSIONS: 16-6'`x -31 =6�� # OF STORIES: 1 TOTAL HABITABLE SPACE: 5'37 MAIN FLOOR TO SQ. FTG: S-37 2N1" FLOOR SQ. FTG: P UNFIN BASEMENT SQ. FTG: h) A IMPERVIOUS SURFACE AREA: 5 37 FINISHED BASEMENT SQ, FTG: (J& GARAGE SQ. FTG: tJ A. DECK/COV. PATIO SQ. FTG: N A 30% SLOPES ON PROPERTY: ti A # OF BEDROOMS: CONSTRUCTION TYPE: `Aac�d Fc...w.Q HEAT SOURCE: E 1.R a-t SEWER OR SEPTIC? rx:s{ Sapi' :a 4 O. F;..Ci The permitee verifies, acknowledges and agrees by their signature that: 1) If this permit is for construction of or on a dwelling, the dwelling is/will be served by potable water. 2) Ownership of this City of Spokane Valley Permit inure to the property owner. 3) The signatory is the property owner or has permission to represent the property owner in this transaction. 4) All construction is to be done in full compliance with the City of Spokane Valley Development Code. Referenced codes are available for review at the City of Spokane Valley Permit Center. 5) This City of Spokane Valley Permit is not a permit or approval for any violation of federal, state or local laws, codes or ordinances. 6) Plans or additional information may be required to be submitted, and subsequently approved before this application can be processed. SIGNATURE: Method of Payment: ❑ Cash Bankcard #: Authorized Signature: REVISED 2/15/07 ❑ Check DATE: 4//j/�'% ❑ Mastercard ❑ VISA Expires: VIN#: WSEC TABLE 6-2 PRESCRIPTIVE REQUIREMENTS°'1 FOR GROUP R OCCUPANCY CLIMATE ZONE 2 . Option Glazing Area's: % of floor Glazing U-Factor Doors U Factor Ceiling Vaulted Ceiling Ceilings Wall'-2 Above Grade Wall? int Below Grade Wall? ext Below Grade Floors Stabs on Grade Vertical „ Overhead I. 10% 0.40 0.58 0.20 R-38 R-30 R-21 int' R-21 R-12 R-30 R-10 II. 15% 0.40 0.58 0.20 R-38 R-30 R-19+ R-58 R-21 R-12 R-30 R-10 III. 17% 0.37 0.58 0.20 R-38 R-30 R-19+ R-58 R-21 R-12 R-30 R-10 IV. 25% Group R-1 Occupancy Only 0.35 0.58 0.20 R-38 / U=0.031 R-30 / U=0.034 R-21 int' / U=0.054 R-15 R-12 R-30 / U=0.029 R-1 D/ F=0.54 V. Unlimited Group R-3 Occupancy Only 0.35 0.58 0.20 R-38 R-30 R-21 int' R-21 R-12 R-30 R-10 VI. Unlimited Group R-1 Occupancy Only 0.32 0.58 0.20 R-38 / U=0.031 R-30 / U=0.034 R-21 int' / U=0.054 R-15 R-12 R-30 / U=0.029 R-10 / F=0.54 * Reference Case 0. Nominal R-values are for wood frame assemblies only or assemblies built in accordance with Section 601.1. 1. Minimum requirements for each option listed. For example, if a proposed design has a glazing ratio to the conditioned floor area of 13%, it shall comply with all of the requirements of the 15% glazing option (or higher). Proposed designs which cannot meet the specific requirements of a listed option above may calculate compliance by Chapters 4 or 5 of this Code. 2. Requirement applies to all ceilings except single rafter or joist vaulted ceilings. 3. Requirement applicable only to single rafter or joist vaulted ceilings. 4. Below grade walls shall be insulated either on the exterior to a minimum level of R-10, or on the interior to the same level as walls above grade. Exterior insulation installed on below grade walls shall be a water resistant material, manufactured for its intended use, and installed according to the manufacturer's specifications. See Section 602.2. 5. Floors over crawl spaces or exposed to ambient air conditions. 6. Required slab perimeter insulation shall be a water resistant material, manufactured for its intended use, and installed according to manufacturer's specifications. See Section 602.4. 7. Int. denotes standard framing 16 inches on center with headers insulated with a minimum of R-5 insulation. WSEC Builder's Field Guide 5th Edition COOPERATIVE EXTENSION WASHINGTON STATE UNIVERSITY ENERGY PROGRAM 1-7 EMERGENCY EGRESS REQUIREMENTS FROM SLEEPING ROOMS 1) NET CLEAR OPENING. 5.7 SQUARE FEET GRADE FLOOR OPENING (MAX 44`) 5.0 SQUARE FEET 2) NET CLEAR OPENING HEIGHT 24 INCHES 3) NET CLEAR OPENING WIDTH 20 INCHES 4) MAX FINISHED SILL HEIGHT 44' ABOVE FLOOR 5) EMERGENCY ESCAPE & RESCUE OPENING SMALL BE OPERATIONAL FROM THE INSIDE OF THE ROOMVRTHOUT THE USE OF KEYS OR TOOLS WHEN INTERIOR ALTERATIONS, REPAIRS OR ADDITIONS REQUIRING A PERMIT OCCUR, OR WHEN ONE OR MORE SLEEPING ROOMS ARE ADDED OR CREATED IN EXISTING DWELLINGS, THE DWELLING UNIT SHALL BE PROVIDED WITH SMOKE ALARMS LOCATED AS REQUIRED FOR NEW DWELLINGS. SMOKE ALARMS SHALL BE INTERCON- NECTED AND HARD WIRED IN SUCH A MANNER THAT THE ACTIVATION OF ONE ALARM WILL ACTIVATE ALL ALARMS. (BEDROOMS, AREAS APPROACHING BEDROOMS, VAULTED CEILING WITH RISE OF 24' & ON EACH FLOOR) & EXHAUST FANS 1-00.CFM kitchen. 50 CPM bathrooms' &'laundry va,,JT& ro t K i - 6 o--- tn r , o43 (Po • Cry U D 7 PROVIDE DIAGRAMS AND ENGINEERING LAYOUTS FOR ROOF TRUSSES, BEAMS AND FLOOR SYSTEMS PRIOR TO FRAMING INSPECTIONS CITY COPY THIS BUILDING SUBJECT TO FIELD INSPECTION CORRECTIONS SIlame REVIEWED FOR COD COMPLIANCE SPOKANE VALLEY B LDING IVISION