PERMIT APPLICATION WORK SHEET
SPOKANE VALLEY COMMUNITY DEVELOPMENT
BUILDING DIVISION
11707 East Sprague Ave Ste 106
Spokane Valley, WA 99206
Phone: (509)688-0036 Fax: (509)688-0037
REQUIRED SITE INFORMATION
STREET ADDRESS: / p FAN E . FE121ZET' DR. •
ASSESSOR'S TAX PARCEL NUMBER(S): 0 y a • a 00 %
LEGAL DISCRIPTION: M Y i o r ES t es- N 0 0 Li I
PERMIT DESCRIPTION: OETAGAEO
&A%'ra CrE-
is BUILDING PERMIT 0 CHANGE IN USE 0 GRADING
E RELOCATION
['SIGN 0 TENANT
O MANUFACTURED HOME
0 OTHER
OWNER / APPLICANT INFORMATION
la OWNER: JAmES 1Z UAr A WAY
PHONE: 6'91 - b i?Z (o FAX:
ADDRESS: /02/6 E• FERRET DR SPeKANE vAILE �u4
CITY,STATE, ZI'P
APPLICANT: t-e-virce4—
PHONE: FAX:
ADDRESS:
CITY, STATE, ZIP
ARCHITECT:
PHONE: 7/0 - 2_ SP FAX: PHONE:
ADDRESS:
FAX:
CITY, STATE, ZIP
CONTACT:
PERMIT/BUILDING INFORMATION
COST OF PROJECT: //5 °� 30% SLOPES ON PROPERTY:
BUILDING HEIGHT TO PEAK: iS�a LESSOCCUPANCY GROUP:
BUILDING DIMENSIONS: 2'/ 4 30
NUMBER OF STORIES:
NUMBER of BEDROOMS:
FLANKING SETBACK:
FRONT SETBACK:
REAR SETBACK:
LEFT SETBACK:
MAIN FLOOR SQ FT:
2ND FLOOR SQ FT:
CONSTRUCTION TYPE: UNFIN BASEMENT:
STRUCTURES ON PROPERTY: No%1 E FINISHED BASEMENT: -
CRITICAL AREAS: - GARAGE: 2 t X 70 X
CURRENT PROPERTY SIZE: COVERED DECK: -
PRIVATE
CURRENT PROPERTY USE:_pwELutni&ARF_$,
CURRENT SEPTIC USE: ,*w-
CURRENT WELL USE: -
DECK: -
RIGHT SETBACK: IMPERVIOUS SURFACE AREA:
MANUFACTURED HOME SIGN
WIDTH: LENGTH:
YEAR: PIT SET:
MANUFACTURER:
_RELOCATION
PREVIOUS ADDRESS:
SQ FT OF SIGN:
# OF SIGNS:
TYPE OF SIGN:
HEIGHT OF SIGN:
AREA OF EXIST SIGN:
FIRE SAFETY
PROPOSED USE:
FIRE SPRINKLER:
PAINT BOOTH:
FIREWORKS DISPLAY:
BLASTING:
FIRE ALARM:
TENT:
DATE/TIME:
WA STATE NON-RESIDENTIAL ENERGY CODE
PLANS EXAMINER:
ADDRESS:
PHONE: FAX:
INSPECTOR:
ADDRESS:
CITY, STATE, ZIP
PHONE: FAX:
CITY, STATE, ZIP
SPECIAL INSPECTIONS
® BOLTING ®CONCRETE ® REINFORCEMENT ® WELDING
FIRM NAME:
INSPECTOR(S):
PHONE: FAX:
BUILDING STAFF USE ONLY
i
IS PUBLIC SEWER AVAILABLE:
IS PUBLIC WATER AVAILABLE:
® YES ® NO
0
YES NO
IF YES: COUNTY ® CITY
IF YES, WHICH WATER DIST/IRR:
IS PROPERTY LOCATED WITHIN DESIGNATED STORMWATER CONTROL AREA: ® YES El NO
IS THE PROPERTY LOCATED WITHIN ASA: ® YES ® NO PSSA: ® YES ® NO
DATE:
1
STAFF:
METHOD OF PAYMENT,
0 0 0 - 0
CASH CHECK
VISA
BANKCARD #; EXPIRES: VIN #
AUTHORIZED SIGNATURE:
*FAXED PERMIT APPLICATIONS WILL ONLY BE ACCEPTED WITH MAJOR BANKCARD
r
..1•
Z. PCICRs 1
APPROVED BY
FE_R,QF r
�R.
I u'
SPoxw Cow
Division of Building and Code Enforcement
B43
Following is a typical cross-section for a resi e age. It may or may not represent the proposed project. If you are using this
detail as a portion ofyour .1 I�t1al� s omplete the requested information in the boxes provided on both sides ofthis sheet.
A c . • i Icy SO information needs to be submitted with your application and be on site at the time of
i 1p TENGINEERED TRUSS OR,
RAFTERSIZE AND SPACING
ROOFING MATERIAL
ROOFING PAPER #15 MINIMUM
ROOF SHEATHING TYPE
STUDS
TREATED SILL
1/2" X 9" ANCHO
BOLTS 9 6' 0" O.C.
3 1/2" CONCRETE SL
OXI 1@ O.C.
77/6
6
•
(2) #4 REBAR
is
ALTERNATE FOUNDATION FOR
ACCESSORY BUILDINGS FROM
1000 SQ. FT. TO 3000 SQ. FT.
NOTE:
1.
Diagonal wall bracing required on
each corner and every 25 feet of wall.
2. Walls within 3 feet of a property line or
within 6 feet of a dwelling must be 1 hour
rated. (5/8" type "X" gypsum sheathing
on both sides of wall). Openings are not
permitted in these walls. Garages over
3,000 sq. ft. require protection when
closer than 20 feet to the property line.
Parapets may be required.
3. Doors entering a garage from the
house must be 1 3/8" solid core or carry a
20 minute fire rating (self -closing hinges
required). These common walls must also
be protected on the garage side with 5/8"
type 'x' gypsum sheathing.
SOLID BLOCKI
BETWEEN TRUSSES
SIDING
6" min.
DOUBLE TOP PLATE
WALL HEIGHT
2X
PRESSURE
TREATED
PLATE
o
FOUNDATION DEPTH r' 1 1 3 1 /2"
18" (Detached) CONCRETE
24" (Attached) •• SLAB
6" X 12" FOOTING
SECTION AA
4 y
O.C.
ANCHORBOLTS
1/2" X 9"
',MINIMUM (7"
CONCRETE) 6'
O.C. OR
APPROVED
ANCHOR
INSTALLED PER
MANUFACTURER
ALTERNATE
FOUNDATION
(DETACHED
UNDER 1000
SQ. FT.)
For more information or an appointment contact:
Spokane County Division of Building and Code
Enforcement
1026 W. Broadway, Spokane, WA 99260-0050
(509) 477-3675 BACE@spokanecounty.org
FOUNDATION PLAN
PLEASE COMPLETE THE FOLLOWING INFORMATION AND ADD ON THE
DRAWING BELOW
BUILDING DIMENSIONS: Z. 9 /14 30
GARAGE DOOR OPENING AND HEADER SIZE- //
INDICATE THE LOCATION AND SIZE OF ALL WINDOWS AND DOORS ON
THE PLAN
L
Ridge Line
Width
L
J
$ f e pepwii
r
A
J
Please note that while every effort is made to assure the accuracy of the information contained in this brochure it is not warranted for accuracy.
This document is not intended to address all aspects or regulatory requirements for a project and should serve as a starting point for your investiga-
tion. For detailed information on a particular project, permit, or code requirement refer directly to applicable file and/or code/regulatory documents or
contact the appropriate division or staff.
(B-13) 01/02
Number of Floors
Supported by the
Foundation
1 iLLa.ALGJJ VL 1'V uuU6aavLa aaa
(inches)Thickness
Width of Footing
(inches)
of
Footing
(inches)
Concrete
Unit Masonry
1
6
6
12
6
2
8
8
15
7
3
10
10
18
8
Table II
Minimum Reinforcement Requirements
for Concrete or Solid Masonry Foundation Walls
Unbalanced Fill
Minimum Wall
Thickness
Horizontal
Bar
Vertical
Bar
4 feet or less
See Table I
Not Required
Not Required
8 feet or less
See Table 1
(2) No. 4
No. 3 @ 18" o.c. d
or No. 4 @ 24" o.c. ,
)
More than 8 feet
Design Required
Design Required
Design Required
1. Bottom of footing placed 24" below finish grade except as specified in Section 3.03.030 of the
County Code for detached accessory buildings.
2. The ground under the floor may be excavated to the elevation of the top of the footing.
3. Foundations may support a roof in addition to the number of floors. Foundations supporting roofs
only shall be as required for supporting one floor.
4. Horizontal reinforcement is to be located in the upper 12" of the wall.
5. Backfilling shall not be commenced until after the wall is anchored to the floor and as specified in
Chapter 18 of the U.B.C.
NOM: These requirements are applicable only when the wall is restrained by an acceptable diaphragm
(i.e., floor slab, floor joist, etc.).
SPOKANE COUNTY PRINTING DEPT. (B-12) 05/00