Loading...
2005, 12-08 Permit App 05004623 Steel Beam11707E Sprague Ave, Suite 106 , �>r Permit Center Spokane Spokane Valley, WA 99206 (509)688-0036 FAX: (509)688-0037 Community Development www•spokanevalley.org.cor valley Residential Construction Permit Application FE o New Construction o Addition/Remodel Q-Other: l/ 5.75 ❑ Accessory Bldg o Deck SITE ADDRESS E . !cols CE2QaT Oft_ ASSESSORS PARCEL NO: — Spo k1►-U UaLL.L.(, L04 _ LEGAL DESCRIPTION: 3niidin owner _ 7 ti _ Name: j ' 2t.S1(,_,I, 4 L \I ) <Arnsz r Address: E. I Cb l P, T OR- , City:. 5: :,ICAuc UAL- t Zip: Gl C1 Xc- Phone: cfcfy-S4ciL1 Fax: 911,89G(o ContactPerson Name: , SZ w 12 ak Phone: C1c1( �4 q L( Gaon Name: (In EDw✓I aiL Address: City: Zip: Phone: Fax: Lic No: Exp. Date: City Business Lic No: Describe the scope of work in detail: Cost of Project: It �ACi�I C� LIC01-) Lax Frn IuOW i 4WD I :S) W i i t-1 STEEL p(Ow, S,Gtr �-0 Ii2i)aa **************The following MUST be complete: (write N/A if not applicable)********************** HEIGHT TO PEAK: )v l r-V DIMENSIONS: 1414 # OFISTORIES: ! TOTAL HABITABLE SPACE: 30 'S Q F(, MAIN FLOOR TO SQ. FTG: I -IUD 2N" FLOOR SQ. FTG: AJfil UNFIN BASEMENT SQ. FTG: I,:il4 IMPERVIOUS SURFACE AREA: ,�i/1-} FINISHED BASEMENT SQ. FTG: I SC'._-'1 GARAGE SQ. FTG: /4 DECK/COV. PATIO SQ. FTG: Ale 30% SLOPES ON PROPERTY: U %4- # OF BEDROOMS: nlerl AIIIACr. CONSTRUCTION TYPE: Ll000 2P111(►E HEAT SOURCE: C A SEWER OR SEPTIC? S r!z The permitee verifies, acknowledges and agrees by their signature that 1) If this permit is for construction of or on a dwelling, the dwelling is/will be served by potable water. 2) Ownership of this City of Spokane Valley Permit inure to the property owner. 3) The signatory is the property owner or has permission to represent the property owner in this transaction. 4) All construction is to be done in full compliance with the City of Spokane Valley Development Code. Referenced codes are available for review at the City of Spokane Valley Permit Center. 5) This City of Spokane Valley Permit is not a permit or approval for any violation of federal, state or local laws, codes -or ordinances: 6)-Plans or additional information may be required to be submitted, and subsequently approved before uuessed. Signature Date I - 0--0 S Method of Payment (Faxed permit applications will only be accepted with major bankcard) ❑ Cash 0 Check 0 Mastercard 0 VISA Bankcard #: Expires: VIN#: Authorized Signature: REVISED 8/252005 0 Other Permit Center St °Tare 11707 E Sprague Ave, Suite 106 .` V alle Spokane Valley, WA 99206 (509)688-0036 FAX: (509)688-0037 www.spokanevallev.ora.com . Community Development Residential Plan Submittal Minimums ❑ Completed Building, Plumbing & Mechanical application with: Accurate address, Parcel Number and/or Legal Description, description of work, owner and contractor information, signature, and date. ❑ Two sets of plans including Site Plan, elevations, floor plans, foundation plans With details, roof plan, framing plans & details. ❑ Show the height of any proposed buildings or accessory structures. O Floor plan for each floor: Dimension to scale (minimum 1/8") and label each Room (including sq. footage of house and garage on plans) Show each level of existing house and square footage of any additions. ❑ All braced wall panel types: show locations and details of installation, including engineered design. ❑ Egress windows: Provide at least one window or exterior door approved for Emergency escape or rescue from a basement and in every room for sleeping. p Smoke detector locations ❑ 22" X 30" attic access location ❑ 18" X 24" crawl space access: ❑ One -hour separation detail: between house and garage ❑ Floor framing details: Joist type, size, spacing and installation details ❑ Roof framing plan and details ❑ Fumace and hot water heater location. ❑ All header locations: type, size, and connections ❑ Foundation plan ❑ Insulation information vsQ i F=y J ST DEPT4 4 Vit.- T S 4 � 4 je 3z g G-, e4 CFL4'3 �31t.,r4x o' -0q Z' 34-gii2A323- 2 aa�.c e N0TES.1, HLS, i3 i(.o U, Z. FlWtSH: ONES/f pR►ME�' Cot-.SBM/.1ST CaoW c. 1 N it, FABRI CAT QRS)INC. MAIL: P.O. 6O 11754. SPOKANE. WA..99211 PHONE: (509) 534-1676 SHIP_ E. 5014 KNOX. SPO:XANE. M A- 99212 FAX : (509) 535'7135 N 3 Cot-.SBM/.1ST CaoW c. 1 Uniformly Loaded Floor vices Northwest o : 03-20-2003 : 4 25:05 PM By: Oscar M. Torres . Design S Protect: 0305-PLR - Location: Basement Beam Summary: A36 W8x48 x 22.5 FT Section Adequate By: 56.5% Controlling Factor: Moment of Inertia Deflections: DLD= 0.17 IN Dead Load: LLD= 0.48 IN = U563 Live Load: TLD= 0.65 IN = U415 Total Load: Reactions (Each End): LL-Rxn= 4991 LB Live Load: DL-Rxn= 1788 LB Dead Load: TL-Rxn= 6778 LB Total Load: 1.19 IN Bearing Length Required (Beam only, Support capacity not checked): BL= Beam Data: Span: Lu= 1.33 FT L= 22.5 FT Unbraced Length -Top of Beam: L/ 360 Live Load Deflect. Criteria: L/ 360 Total Load Deflect. Criteria: Floor Loading: LL1= 40.0 PSF Floor Live Load -Side One: LL1= 10.0 PSF Floor Dead Load -Side One: �W 1= 10.0 FT Tributary Width -Side One: LL2= 5.46 FT PSF Floor Live Load -Side Two: DL2= 40.0 PSF Floor Dead Load -Side Two: TW2= 10.0 FT Tributary Width -Side Two: WALL= 0 FT Wall Load: PLF Beam Loading: PLF Beam Total Live Load: gSWwL= 4444PLF wD== 14 Beam Self Weight:8 PLF 8 Beam Total Dead Load: wT= 159 PLF Total Maximum Load: Properties for: W8x48/A36 Fy- 36 KSI Yield Stress: E= 29036 KSI Modulus of Elasticity: d= 8.00 N Depth: tw= 0.40 N Web Thickness:N Flange Width: tf= 8bf= 8.11.N Flange Thickness: 6 Distance to Web Toe of Fillet: I18 k= 1.19.N N4 x Moment of Inertia About X-X Axis: - 849 .00 N3 Section Modulus About X-X Axis: = 2.24 N Radius of Gyration of Compression Flange + 1/3 of Web: Design Properties per AISC Steel Construction Manual: FgR- 5.92 Flange Buckling Ratio: AFBR= 15.92 Allowable Flange Buckling Ratio: 21.25 WgR- Web Buckling Ratio: AWR= 106.67 Allowable Web Buckling Ratio: 1.33 FT Lc= Controlling Unbraced Length: Lb-8.56 FT Limiting Unbraced Length for Fb=.66*Fy: c= 23.76 FTI Allowable Bending Stress: h/tw-Limit3.72 1 h/tw= Web Height to Thickness Ratio: 7.82 Limiting Web Height to Thickness Ratio for Fv=.4*Fy: Fit 1.33 KSI Allowable Shear Stress: Design Requirements Comparison: 127 FT -LB Mr= 38127 Controlling Moment: M= 38FT-LB Nominal Moment Strength: 5734 LB �4677 Controlling Shear: V= 8 LB 8 Nominal Shear Strength: Ireq- 48960 IN4 Moment of Inertia (Deflection): I- 184.00 IN4 Uniformly Loaded Floor Beam( AISC 9th Ed ASD ) Ver: 5.07 By: Oscar M. Torres , Design Services Northwest on: 03-20-2003 Project: 0305-PLR - Location: Basement Beam Summary: A36 W8x48 x 22.5 FT Section Adequate By: 56.5% Controlling Factor: Moment of Inertia LOADING DIAGRAM W Span = 22.5 ft Reactions Live Load Dead Load Total Load Uplift Load A 4991 Lb 1788 Lb 6778 Lb 0 Lb B 4991 Lb 1788 Lb 6778 Lb 0 Lb Span Uniform Loading Live Load Dead LoadSelf Weight Total Load W 444 Plf 111 Plf 48 Plf 603 Plf Column( 97 Uniform Building Code (91 N By: Oscar M. Torres , Design Services Northwest, Inc. o Project: 0305-PLR - Location: COLUMN Summary: 5.5 IN x 5.5 IN x 8 FT / #2 - Douglas Fir -Larch - Dry Use Section Adequate By: 47.5% Vertical Reactions: Live: Dead: Total: Axial Loads: Live Loads: Dead Loads: Column Self Weight: Total Loads: Eccentricity (X-X Axis): Eccentricity (Y-Y Axis): Axial Duration Factor: Column Data: Length: Maximum Unbraced Length (X-X Axis): Maximum Unbraced Length (Y-Y Axis): Column End Condition: Calculated Properties: Column Section (X-X Axis): Column Section (Y-Y Axis): Area: Section Modulus (X-X Axis): Section Modulus (Y-Y Axis): Slenderness Ratio: Properties For: #2- Douglas Fir -Larch Compressive Stress: Modulus of Elasticity: Bending Stress (X-X Axis): Bending Stress (Y-Y Axis): Adjusted Properties: Fc': Adjustment Factors: Cd=1.00 Cp=0.91 Column Calculations (Controlling Case Only): Controlling Load Case: Axial Total Load Only (L + D) Compressive Stress: Allowable Compressive Stress: DS) 1 Ver: 5.07 n: 03-21-2003 : 10:30:10 AM Vert-LL-Rxn= Vert-DL-Rxn= Vert-TL-Rxn= PL= PD= CSW= PT= ex= ey= Cd-Axial= L= Lx= Ly= Ke= dx= dy= A= Sx= Sy= Lex/dx= Ley/dy= Fc= E= Fbx= Fby= Fc'= fc= Fc'= 4991 LB 1855 LB 6846 LB 4991 LB 1788 LB 67 LB 6846 LB 0.00 IN 0.00 IN 1.00 8.0 FT 8.0 FT 8.0 FT 1.0 5.50 IN 5.50 IN 30.25 IN2 27.73 IN3 27.73 IN3 17.45 17.5 475 PSI 1300000 PSI 700 PSI 700 PSI 431 PSI 226 PSI 431 PSI ID REVISIONS EXIST(' 3/4' T4E, SEBELP EAST* 2xt0 0 4.....1-C• 1,1,0' 2-200 SE,P50.113A TOP 1'l_046e HAIRSER PR MIR. 4/01/2. FILLET EELD TO E.A. sice OE EA. tOP PLANS* FOR 14 I 12 SARSE 3/11ex2" FILLET EsELO TO EA. SiDE 01/ EA. TOP PLANS@ TAB FOR sAIASE, OISTREUTE nap ErEALLY ON BOTH TOP RAMSES BEAM SECTION — 7,P,1:152$1,10 PLR JOISTS 7310 FILLER ELK'S 2x4 441/4)414441.1. HOLD 2' OVT FROM 4 INEULATE 4.4/ R-21 !DARTS — exero CONC. SLAB 110X3E. t/2' 0444. TOR) EOLTS V2' PLATE WIENER E49.5.9 ASO STEEL EN 0 WALL SECTION x.AL.E, r-o• 114. 3/4' DIAX5' EXPDXY DOLTS EV 4' MN. ereep (4 TYE) rftor vey, BEAM CONNECTION DETAIL soALe. extsit, FON I Fro 41/4X51/6. TS = I I 1/2' PLATE 4x4x3/16. 1/5 1/2" 0IA,10* EXPCXY DOLTS PR MIN. 7 PHEW BEAM CONNECTION DETAIL ZGALMt W-2 V2' Pato STEEL 3/4 r AP rwrm MAR. OFTA0 BASEMENT FLOOR PLAN 0:0111C4T COPIEfillO IAO NOIR WS�o ALTMO NO IVAi flOO1501 ROM MON SOME NOORMIST Ill MONO iS9IIIED VAMIOV 7:14 Miff MEMO IOW Mt ISOM OF ME MO COS MOIL BE LIZA MMOPEFIOME INON RC= - DRAWN BY O.M.T CHECKED BY 0.M.T DATE T-25-05 JOB NO, 0305-PLR SHEET NO. A- 1 SCALO, 1/4, P-0. PROVIDE DIAGRAMS AND ENGINEERING LAYOUTS FOR ROOF TRUSSES, BEAMS AND FLOOR SYSTEMS PRIOR TO FRAMING INSPECTIONS Cl Y C 1 THIS BUILDING SU ECT TO hIELD INSPECTION CORRECTIONS REVIEWED FOR CODE COMPLIANCE SPOKANE VALLEY BUIL. INC DI SION 7 vs-