1992, 06-05 Permit 92001765 Radon Mitigation System• auuttzr hrporalian E. 8620 991h Spokane, Ila. 99206 Phone 509 926-6217 Fax 509 928-8689 Legend for Radon mitigation system — —perforated pipe beneath slab CO solid 4'ABS stack vent pipe RADON SYSTEM SPECIFICATIONS ATT RADON MITIGATION SYSTEM This radon mitigation system is designed only for the specific job - site address designated. The system is not guaranteed unless installed by Cavalier Corporation Sub Slab System YES SQ FT Cravlspace System SO FT Jurisdiction COUNTY Project Number War n J . f iAd.1 4�t. Environmental Protection Agenc P,R .Pi`�►P 4,4��'' •: 171111 1 THESE PLANS HAVE BEEN REVIEWED )4L-7- Rio a sy 5 7-- BY e4f • ON 6-5-_/2 Jobsite E. 10108 FERRET Builder Address JORDAN CONSTRUCTION P .0 , BOX 212 NEUMAN LAKE, 99025 Phone 226-3514 92 - (-765- i RADON VE. ... NT BASEMENT GARAGE Qatrn1ir engineering radon services E. 8620 44th Spokane, WA 99206 Phone (509) >1O-6217 FAX (509) 928-8689 RADON SYSTEM SPECIFICATIONS, SPOKANE COUNTY: t 1. Perforated pipe shall be installed within the native soil or fill (sand, gravel or soil) at a minimum depth of 1" below the intended 2. The pipe shall be a minimum diameter of 4". meet AASHTO M252, have perforatio s no wider than 1/16" and have a minimum of 2.5 square inches of total perforations per linear foot of pipe. 3 There shall be a min um of 10 linear feet of perforated pipe per hundred square feet of slab floor space. 4 The pipe shall be laid in a continuous loop. connected at_ both ends to the solid stack vent pipe. 5. Any slab area, which is larger than 10 square feet, which is isolated from other slab areas by footings or other barriers, shall have a perforated pipe installed to the above specifications. (The pipe can be a single Length rather than a connected loop if the area is too small or narrow to accomodate a connected loop.) 6. A stack vent of ABS, schedule 40, minimum size 4", shall be connected to the sub -slab piping and proceed upwards to an exit location ea the roof. and extending 14" above the roof. The pipe shall be labeled "radon vent" every 16" or less for its full length. The pipe's attic location shall allow a minimum of 4' of head room. When- ever possible this exit location shall be on the backside of the roof. 7. Any elbows in the stack vent piping shall have a centerline radius aiia4mum of 1.5 by pipe width. 8. An inline centrifugal fan, minimum 114 cfm @ 3/8" W.C., UL listed, manufactured specifically for radon mitigation, maximum sone level 2.8, shall be installed in the exhaust line, in the attic. 9. Couplings to connect the vent piping to the fan shall be elastomeric PVC, Fertco series 1056 or equal. 10. The fan shall be hard -wired and the breaker labeled "radon fan". 11. All penetrations and joints in the concrete floor slab below grade shall be sealed with caulk or grout. 12. A notice shall be permanently attached to the electrical panel advising the owner or occupant about the radon system and that he/shm shall test the home for radon annually. The notice shall include Cavalier's name and_ phone number. 13. All craftsmanship shall be of high quality.