1992, 12-07 Permit App 92010702 Residence, Heat PumpSPOKANE COUNTY DEPARTMENT OF BUILDINGS
W. 1303 BROADWAY AVENUE
SPOKANE, WASHINGTON 99260
(509) 456-3675
I certify that I have examined this permit/application, state that the information contained in it and submitted by me or my agent to compile said permit/application is true
and correct, and authorize Spokane County to proceed with processing. In addition, I have read and understand the INSPECTION REQUIREMENTS/NOTICE
provisions included herein and agree to comply with same. All provisions of laws and ordinances governing this type of work will be complied with whether specified
herein or not. I understand that the issuance of this permit/application and any subsequent inspection approvals or Certificates of Occupancy shall not be construed to
give authority to violate or cancel the provisions of any state or local law regulating construction, or as a warranty of conformance with the provisions of any state or local
laws regulating construction.
SIGNATURE OF
OWNER OR AGENT
*Ibe72
2
�� r o-`I 2_ �� y
A)-7-cia , GEK,
jA /147,..,„A7,
‘). ,;1- "1"
1 Cot AI S',- %(0 -92 /-'7tr--,c, ,-
/z -7-72- _
SPOKANE COUNTY DEPARTMENT OF BUILDINGS
W. 1303 BROADWAY AVENUE
SPOKANE, WASHINGTON 99260
(509) 456-3675
I certify that I have examined this permit/application, state that the information contained in it and submitted by me or my agent to compile said permit/application is true
and correct, and authorize Spokane County to proceed with processing. In addition, I have read and understand the INSPECTION REQUIREMENTS/NOTICE
provisions included herein and agree to comply with same. All provisions of laws and ordinances governing this type of work will be complied with whether specified
herein or not. I understand that the issuance of this permit/application and any subsequent inspection approvals or Certificates of Occupancy shall not be construed to
give authority to violate or cancel the provisions of any state or local law regulating construction, or as a warranty of conformance with the provisions of any state or local
laws regulating construction.
SIGNATURE OF APPLICATION _
OWNER OR AGENT DATE
Spokane County
DEPARTMENT OF BUILDINGS
West 1303 Broadway Avenue Spokane, WA 99260 (509) 456-3675
INFORMATION WORKSHEET
ne
PARCEL NUMBER:
STREET ADDRESS:. -
CITY/STATE/ZIP: Sff c'9 /E /,/./ /%f
SUBDIVISION:
BLOCK:
LOT AREA:
I OF BUILDINGS:
OWNER:
LOT:
F/A:
ZONE: DISTRICT:
WIDTH:
# OF DWELLINGS:
-T1-14 j /.hL /4 A
MAILING ADDRESS: ?(p/(p f 7/7r,,7/-7o;
CITY/STATE/ZIP: 0"1.22_ y*,(/, b '4_
CONTACT:
DEPTH: R/W:
WATER DISTRICT:
PHONE: ,5D 9 - 772/ - l /J//
PHONE:
SETBACKS: - FRONT: '/D' LEFT: 025 RIGHT:_3UREAR: /*o
PERMIT USE: A/ / ?L, / $
CONTRACTOR LICENSE NUMBER:
CONTRACTOR:
BUILDING INFORMATION
L 74 Y_ ` // f / lv VC —
t 6,Gt/1/%r7-L1 /'_C) JGS PHONE: ) 07 - �i d / - /; %//
MAILING ADDRESS:
96 /b 7 /1764n
ARCHITECT/ENGINEER: �lvitiz.--f'¢=/d%\t--C,j7- PHONE:
MAILING ADDRESS:
L
NEW: 5 REMODEL: ADDITION: CHANGE OF USE:
DWELL UNITS: OCCUPANT LOAD:
BUILDING DIMENSIONS:
BUILDING HGT:2a
(WIDTH X DEPTH)
STORIES:
SQ. FT.:
REQUIRED PARKING: # HANDICAP: SPRINKLERED:
CRITICAL MATERIAL:
PLEASE PROVIDE THE FOLLOWING INFORMATION FOR ENERGY CODE COMPLIANCE:
SPACE HEATING TYPE (Check One)
FORCED AIR ELECTRIC ELECTRIC BASEBOARD OR WALL MOUNT
FORCED AIR GAS HEAT PUMP
PROPANE OTHER:
FLAT CEILINGS R 7�8 DOORS U f6
VAULTED CEILINGS R ✓ O WINDOWS U yC�
ABOVE GRADE WALLS R / GLAZING AREA 62?-96 , % /0
BELOW GRADE WALLS R / 7 TOTAL FLOOR AREA OF HEATED SPACE:
FLOOR R c2P2? 7
SLAB ON GRADE R FURNACE EFFICIENCY RATING d�O
PLEASE INDICATE ON YOUR PLANS:
The location of the radon vent, and the location of the vent fan area.
SQUARE FOOTAGE:
MAIN FLOOR
SECOND FLOOR
BASEMENT - FINISHED
UNFINISHED
GARAGE
CARPORT
DECKS
ADDITIONAL AREAS:
/
******************************************************************************
LENDER/BOND HOLDER:
ADDRESS 017/.2 / t
CONTACT
4
PHONE 991/ / 7//
nor - Al
1"z-5oI
N.
/?ta.T cr ///0a1>F <c
FERRET
DRIVE
0
ei<s
\,2 So
2iss
2/6 S
217
O
01
0
I
! 't
2 00
W
0
MECHANICAL PERMIT ,APPL!CATION FORM
Information Worksheet
JOB STREET ADDRESS: 5 , 579 f-4-/-7-15
CITY/STATE/ZIP: PARCEL NUMBER:
OWNER: —7-1-fF e—fr-s1PHONE NUMBER: qa/ - 6 7/_/
MAILING ADDRESS: 9'6' / & • 717tPi7F-7 '92 I
. (Street) MCity/State) (Zip)
CONTRACTOR: „gt.f /6--AC4ICENSE NUMBER: 4,V //13 *` /6
PHONE NUMBER: 907/— 7//
MAILING ADDRESS: 579/7) /726, VC_
(Street) (City/State)
MECHANICAL WORKSHEET/FEE SCHEDULE
DESCRIPTION
ELECTRIC/DUCTWORK (SEPARATE SYSTEMS)
• . .
GAS WATER HEATER
GAS EQUIPMENT +100,00 0BTU DUCTWORK)
PEpi
BOILER/REFRIG 1-100M BTU
BOILER/REFRIG 501-1,000M BTU
•-••
750M BTU
BOILER/REFRIG +1,750M BTU
HEAT PUMP 8, AIR CONDITIONER 3-15 TONS
:mom
HEAT PUMP & AIR CONDITIONER 30-50 TONS
....,... • „ +5o TONS
•• ,
VENTILATING FANS
TYPE I HOOD (PER 12' OR 12' PTN. OF HOOD)
CLOTHES DRYER
RANGE
—mom
GAS LOG
• . .
ELSEWHRE
..
UNLISTED GAS APPLIANCE <400,000 BTU
USED APPLIANCE <400,000 BTU
•• •
AIR HANDLER <10,000 CFM
.6../..OROAROtERI*C
NOTE: MINIMUM PERMIT FEES $35.00
SIGNATURE
(Zip)
NUMBER
OF UNITS
X EACH
UNIT
= AMOUNT
x 10.00 =
x 25.00 =
x 10.00 =
x 12.00 =
x 15.00 =
x 1.00 =
x 12.00 =
x 20.00 =
x 25.00 =
x 35.00 =
x 60.00 =
x 12.00 =
x 20.00 =
x 25.00 =
x 35.00 =
x 60.00 =
x 1 o.00 =
x -moo =
x 50.00 =
x 10.00 =
x 10.00 =
x 10.00 =
x 10.00 =
x10.00 =
x 50.00 =
x100.00 =
x 50.00 =
x100.00 =
x 12.00 =
x 15.00 =
/
O.
/ —
/
Id.
8:1
c:R.
/
/4=•,? • —
5
.3o,. --
/
/
/ 0 —
/
/ 0 . —
SUBTOTAL
$ ZP 9, ()a
PLUS: PROCESSING FEE
+ $ 25.00
EQUALS: TOTAL PERMIT
FEE DUE
= $
Spokane County Division of Buildings
West 1303 Broadway Avenue Spokane, WA 99260 (509) 456-3675
PLUMBING PERMITAPPLICATION FORM
Information Worksheet
JOB STREET ADDRESS: S - Jl/d 8 % k L TT 6_ //),
CITY/STATE/ZIP: 5e)K_-/4 I24 PARCEL NUMBER:
OWNER: zf;iF A" -P7 — PHONE NUMBER: 5?a/— (p 7//
MAILING ADDRESS: 9 '/G ( ''),Urlty/l7�'
(Street) (CitylState) (Zip)
CONTRACTOR: �- 1-ti //�� - /-4 .ICENSE NUMBER: )4,e6'YB E / , /L-s
PHONE NUMBER: %7/— rp 7//
MAILING ADDRESS: `7 '7& �- l/,794. /.TY�r�/S •�f9-"r✓- 1/24 9 y'a /
(Street) (City/State) (Zip)
PLUMBING WORKSHEET/FEE SCHEDULE
DESCRIPTION
TOILETS
SHOWERS
KITCHEN SINKS
GARBAGE DISPOSAL
UTILITY SINKS
E4EGTR [GWAT>^R:H
FLOOR DRAINS
............................................................................................ .
BAR SINKS
........................................................................................... .
LAWN SPRINKLER - FOR EACH BACKFLOW DEVICE
WATER SOFTENER
DRINKING FOUNTAIN
NOTE: MINIMUM PERMIT FEE IS $35.00
NUMBER
OF UNITS
X EACH
UNIT
= AMOUNT
j
x 6.00 =
x 6.00 =
x 6.00 =
x6.00 =
x6.00 =
x 6.00 =
x6.00 =
x6.00 =
x 6.00 =
x 6.00 =
x 6.00 =
x 6.00 =
x 6.00 =
x 6.00 =
x 6.00 =
x6.00 =
x 6.00 =
x6.00 =
x 6.00 =
/ 0). —
c/
ay, —
P
/a.—
/
�,
/
—
/
6.—
/
/,,_/
/, —
0
O
0
0
0
0
/
U
0
Q
SUBTOTAL
$
PLUS: PROCESSING FEE
+ $ 25.00
EQUALS: TOTAL PERMIT
FEE DUE
= $ 90,-
Spokane County Division of Buildings
West 1303 Broadway Avenue Spokane, WA 99260 (509) 456-3675
A M[MCL ASIDUM
TRIM
acnCouRrt
.B.C. SECTION 1210
• Smoke detectors in new
construction shall be
equipped with a battery
backup In addition to being
hard wired and intertied.
• Smoke detectors shall be
installed *ithin each
sleeping room as well as the
current locations.
U.B.C. SECTION 1712
• The maximum permitted
spacing for intermediate rails
or ornamental patterns in
guardrails has been reduced
to that which a 4-inch sphere
cannot pass through.
&ought b you by
Spokane County Department of Buildings
Summer, 1992
U.B.C. SECTION 2517(d)
• Headers with a span
exceeding 4 feet must be
framed with trimmers and
header rafters that are
doubled or of lumber of
equivalent cross section.
Header rafters over 6 feet in
length shall be supported by
framing anchors or rafter
hangers.
U.B.C. SECTION 3314(e)
• Floor level exit signs are
required in corridors serving
guest rooms of hotels when
exit signs are required by
Section 3314(a).
U.B.C. SECTIONS 3303(b)
& 3306(b)
• A new method of determin-
ing the required exit width
has been included. The
method establishes different
exiting requirements for
stairways than for exits.
MErl-19D
• Occupant load x 0.3 =
required width in inches for
stairs
• Occupant load x 0.2 =
required width in inches for
all other exits
U.B.C. SECTION 2517(h)
• All trusses must be blocked
at all bearing points.
Hurricane clips are not an
acceptable substitute for
blocking.
CHAPTER 33
• Requirements that the
widths of exits be increased
based on a percentage of
the occupants from adjacent
levels have been deleted
from the code. The width of
exits from a story will
based on the occupant load
from that story only, unlessa
larger exit width Is required
from other levels.
U.B.C. SECTION 302(b) &
03 (b)
• Roof truss layouts must be
available for framing
inspections to verify proper
placement.'especialty girder
trusses and specific hangers
or bearing.
U.M.C. SECTION 906(d)
• This section of the
Mechanical Code has been
made more restrictive. Gas
vents must terminate above
the roof and at least 8 feet
from any vertical portions of
the building.
VENTILATION REQUIREMENTS
1. Source specific exhaust ventilation shall be provided in
each kitchen, bath, laundry room, indoor pool, spa or
other areas which produce excessive water vapor or
cooking odors at levels prescribed in VIAQ Table 3-1
measured at 0.25 inches water gauge.
MINIMUM SOURCE SPECIFIC VENTILATION CAPACITY REQUIREMENTS
TABLE 3-1
Intermittently operating
Continuous Operation
Bathrooms Kitchens
50 cfm 100 cfm
20 cfm 25 cfm
2. Whole house ventilation shall provide between .35-.50 ACH.
It shall provide outdoor air to all habitable rooms through
individual outdoor air inlets, forced air heating system,
ducting, or equivalent means. VIAQ 302.2.2 Table 3-2.
WHOLE HOUSE EXHAUST FAN PRESCRIPTIVE REQUIREMENTS
TABLE 3-2
CFM
Bedrooms Minimum Maximum
2 or less 50 75
3 80 120
4 100 150
3. All ducts shall terminate outside the building. Exhaust
ducts in systems which are designed to operate
intermittently shall be equipped with back -draft dampers.
All exhaust ducts in unconditioned spaces and all supply
ducts in the conditioned spaces shall be insulated to a
minimum of R-4.
4. Exhaust duct sizing shall meet the requirements of VIAQ
Table 3-3.
Fan Tested
CFM 0 0.25
or less
or less
or less
50
50
50
51
51
51
81
81
101
101
80
80
80
100
100
-125
-125
*For each
5.
W.G.
PRESCRIPTIVE EXHAUST DUCT SIZING
TABLE 3-3
Minimum Maximum Minimum
Flex Length Smooth
Diameter Feet Diameter
4 inch 25 4 inch
5 inch 90 5 inch
6 inch over 100 6 inch
4 inch Not allowed 4 inch
5 inch 15 5 inch
6 inch 90 6 inch
5 inch Not allowed 5 inch
6 inch 45 6 inch
6 inch 15 6 inch
7 inch 70 7 inch
Maximum
Length
Feet
70
100
Over 100
20
100
Over 100
50
Over 100
Over 100
Over 100
Maximum
Elbows*
3
3
3
3
3
3
3
3
3
3
additional elbow subtract 10 feet from length.
All Ventilation system controls shall be readily accessible.
Controls for whole house ventilation systems without
energizing other energy -consuming appliances. (Continuously
operated whole house ventilation systems switch shall not be
readily accessible by the occupant. VIAQ 302.3
Spokane County
COLD WEATHER CONCRETE
PLACEMENT AND CURING
Department of Buildings 456-3676
1. Unless concrete is cured in accordance with Section 2605 3,
(High Pressure Steam), it shall be maintained above 50 Fahrenheit
and in a moist condition for at least the first seven days after
placement, except that high -early strength concrete shall be so
maintained for at least the first three days. Supplementary
strength tests in accordance with Section 2604 (h) 3 may required
to assure that curing is satisfactory.
2. Only concrete that is prepared by a recognized batchplant where
Calcium Chloride (maximum 2%), air -entraining or other suitable
admixtures and the heating of water and aggregates can be adequately
controlled can be placed in weather where the temperatures drop
below 40 Fahrenheit.
3. Adequate equipment shall be provided for protecting the concrete
during freezing or near -freezing weather. All concrete materials
and all reinforcement, forms, fillers and ground with which the
concrete is to come in contact shall be free from frost. No frozen
materials or materials containing ice shall be used.
4. It will be the responsibility of the Contractor to ascertain the
weather forecast for at least three days following the placement of
the concrete. When temperatures are predicted to range below 40
Fahrenheit, a heated enclosure or other approved methods of protec-
tion will be arranged with the Building Inspector.
EXCEPTIONS:
(A) Footings for single family and duplex residences may be placed
providing provision is made for immediately covering them with straw
or insulation batts succifient to keep the concrete adequately warm
even in zero weather.
(B) Foundation walls for single family and duplex residences must
be protected with plastic or heavy asphalt -impregnated paper for a
minimum period of three days following the placement of the con-
crete.
cald.hnd 03/27/92
Spokane County
RESIDENTIAL STAIRWAY
Department of Buildings
456-3675
HANDRAILS AND HEADROOM
11/2 inches minimum
6'8" minimum
headroom
34"-38"
34"-38"
Nosing
of tread
Intermediate rail spacing or
pattern so that 4-inch sphere
cannot pass through
Triangular area formed
by tread, riser and guardrail so that
6 inch sphere can not pass through
REQUIRED WIDTH OF RUN SHALL
BE PROVIDED IN THIS LOCATION
(SECTION 3306 (d)
HeUU(HtL) WIUI ri or HUN JHALL
BE PROVIDED IN THIS LOCATION
(SECTION 3306 (d)I
NOTE:HANDRAILS
NOT SHOWN FOR CLARITY
'L y- NOTE: HANDRAILS NOT
SSP\GOr SHOWN FOR CLARITY
`yE LIMITATION: APPLIES TO R-3 OCCUPANCY
AND PRIVATE STAIRWAYS IN R-1 OCCUPANCY
PLAN VIEW
ALTERNATE USE OF WINDERS
PLAN VIEW
WINDING STAIRWAY
THE LARGEST TREAD WIDTH
OF RISER HEIGHT WITHIN ANY
I FLIGHT OF STAIRS SHALL
NOT EXCEED THE SMALLEST
BY MORE THAN 3A INCH.
[SECTION 3306 (c)]
t
. bi
T
P
OS
e
PLAN VIEW
CIRCULAR STAIRWAY
WALL
4,
1.4641
HAN
WALL
STAIRWAY
WIDTH
[SECTION 3306 MI
MAXIMUM 912-INCH
RISE BETWEEN TREADS
ta.:44
CENTER SUPPORT 26"M/N
COLUMN
AIRS
LIMITATIONS:
1. ONLY APPLIES TO R-3 OCCUPANCY
AND PRIVATE STAIRWAYS IN
R-1 OCCUPANCIES.
2. LIMITED TO SERVING AS EXIT
FOR 400 SQUARE FEET MAXIMUM.
PLAN VIEW
SPIRAL STAIRWAY
":i
HANDRAIL
NOT ACCEPTABLE
THE HANDRAIL DOES
NOT COMPLY
THE'CONTINUOUS' ERMINOLOGYIN THE CODE.WITH
HANDRAIL CONTINUITY
STAIR DIMENSIONS
- Width (36" minimum)
- Rise (4" minimum - 8" maximum)
- Run (9" minimum)
- 3/8" maximum deviation between riser heights
and between tread lengths --
HANDRATS
- One required (two required if stair is open on
sides) if there are four or more risers.
- Height (34" to 38" above nosing of treads).
- Projection (1-1/2" between handrail and wall).
- Handrails shall be continuous the full length
of the stairs. Ends shall be returned or shall
terminate in newel posts or safety terminals.
GUARDRAILS
- Required if 30" or more above grade.
- Height (36" high at landings - handrail height
at steps).
- Openings (small enough that a 4" diameter
sphere can not pass through).
1,12
NOT ACCEPTABLE
nn"-r,rlA ni c cu Aocc AMn INSTAI I ATIONS—HANDRAIL
0
ti
0
-4s-a
ft"\,,.44
rat
-iTtt=7/74-
. —
I s•t2-
"4" •
ctaSeit; - 6 atris_
.4;
fel ittm tt; ;7. i
SPOKE COUNTY
Department of Buildings
B34
Private Driveway Standards
Pursuant to Section 3.05.050(a)2(ii), Fire Apparatus Access, of Title 3 of the Spokane County Code, Private
Driveways are access roads that serve no more than two parcels. They shall be constructed in substantial
conformance with the following standards as developed and recommended by the Spokane County Fire
Prevention Committee.
PUBLIC
ROAD
■ Max. Grade:
• Width:
■ Turnouts:
• Turnaround:
• Permits:
BASED ON LINE OF SITE
(NOT TO SCALE)
TURNOUT
BASED ON
LINE
OF SITE
12% - 14% maximum (outside rightof--way)
2 - 8% within right-of-way — contact County Engineers Office
12' clear travelway with all-weather surface
One every 300 - 500 feet depending upon line of sight
All-weather surface 20' in total width for 50' in length
Required for driveways over 150' in length
Needs to be within 150' of dwelling
"Hammerhead" or 50' minimum radius cul-de-sac
Required from County Engineer's Office to
connect to county roadway
Approaches and driveways may be subject to
additional standards maintained by
the County Engineer's Office
For more information or an appointment contact:
Spokane County Dept. of Buildings/Permit Center
W. 1026 Broadway, Spokane, WA 99260-0050
(509) 456-3675
SAMPLE 12% SLOPE
100 FT.
DWELLING.
SAMPLE HAMMERHEAD
20 FT.