2006, 05-18 Permit App 06001823 AdditionProject Number: 06001823 Inv: 1
Application
THIS IS NOT A PERMIT
Penalties will be assessed for commencing work without a permit
Project Information:
Permit Use: BATH/KITCHEN REMODEI. Contact: PETERSON, DAVID J & SHERRIE L
4t R I 4) Address: 2633 N GARY LAURI CT
C - S - Z: SPOKANE, WA 99206
Setbacks: Front Left: Right: Rear: Phone: (509) 893-8962
Group Name:
Site Information: Project Name:
Plat Key: Name: Range
District: Nort
Parcel Number: 45091.1802 Block:
SiteAddress: 2623 N GARY LAURI RD
Location:: CSV
Zoning: UR-22
Water District:
Urban Residential-22
Area: 12,520 Sq Ft Width: 0
Nbr of Bldgs: 0 Nbr of Dwellings: 0
Review Information:
Lot:
Owner: Name: PETERSON, DAVID J & SHERRIE
Address: 2633 N GARY LAURI CT
SPOKANE, WA 99206
Hold: ❑
Depth: 0 Right Of Way (ft): 0
Date: 5/18/2006 Page 1 of 2
Review
Building Plan Review
Originally Released: 5/18/2006 By: TMELBOU
Landuse/Zoning/HE Conditions
Released By:
Sewer Review
Permits:
Originally Released: 5/15/2006 By: Mharnois
Released By:
Originally Released: 5/18/2006 By: amblake
Operator: AMB Printed By: AMB Print Date: 5/18/2006
Project Number: 06001823 Inv: 1
Application
THIS IS NOT A PERMIT
Penalties will be assessed for commencing work without a permit
Building -Permit
Contractor: OWNER Firm: OWNER
Phone: (000) 000-0000
This Application: Total Project:
Description Gar Type Notes Sq Ft Valuation Sq Ft Valuation
1&2 FAMILY R-3 VB owner 0 $20,000.00 0 $20,000.00
Item Description
RESIDENTIAL PERMIT FEE
WSBC SURCHARGE
SF PLNS RVW < 7999 SQ FT
Notes:
Totals: 0 $20,000.00 0 $20,000.00
Units Unit Desc
1 SELECT
1 SELECT
1 SELECT
Permit Total Fees:
Fee Amount
$321.25
$4.50
$128.50
$454.25
Date: 5/18/2006 Page 2 of 2
Payment Summary:
Permit Type
Building Permit
Fee Amount Invoice Amount Amount Paid Amount Owing
$454.25 $454.25
$0.00 $454.25
$454.25 $454.25 $0.00 $454.25
Disclaimer:
Submittal of this application certifies the owner (or person(s) authorized by the owner) has both examined and finds the information
contained within to be true and correct, and agrees that all provisions of laws and/or regulations governing this type of work will be
complied with. Subsequent issuance of a permit shall not be construed to be a permit for, or an approval of, any violation of any of
the provisions of the code or of any other state or local laws or ordinances.
Signature:
Operator: AMB Printed By: AMB Print Date: 5/18/2006
Project Number: 06001823 Inv: 1
Application
THIS IS NOT A PERMIT
Penalties will be assessed for commencing work without a permit
Project Information:
Date: 5/12/2006 Page 1 of 2
Permit Use: BATH/HITCHEN REMODEL Contact: PETERSON, DAVID J & SHERRIE L
C7 C) t Tro ' Address: 2633 N GARY LAURI CT
C - S - Z: SPOKANE, WA 99206
Setbacks: Front Left: Right: Rear: Phone: (509) 893-8962
Group Name:
Site Information: Project Name:
Plat Key: Name: Range District: Nort
Parcel Number: 45091.1802 Block:
SiteAddress: 2623 N GARY LAURI RD
Location:: CSV
Zoning: UR-22
Water District:
Area: 12,520 Sq Ft
Urban Residential-22
Width: 0
Nbr of Bldgs: 0 Nbr of Dwellings: 0
Review Information:
Lot:
Owner: Name: PETERSON, DAVID J & SHERRIE
Address: 2633 N GARY LAURI CT
SPOKANE, WA 99206
Hold: ❑
Depth: 0 Right Of Way (ft): 0
Review
Building Plan Review
Released By: 1 4/o V
Landuse/Zoning/HE Conditions
Released By:
Sewer Review
Permits:
rieLscIVED
SPOKANE VALLEY
DEPARTMENT Of
COMMUNITY DEVELOPMENT
Contractor: OWNER
Released By:
Building Permit
Firm: OWNER
Phone: (000) 000-0000
Operator: AMB Printed By: AMB Print Date: 5/12/2006
RECMWE D
MAY 1.1
Permit Center ❑
Spo°`kane 11707 E Sprague Ave, Suit Spokane Valley, WA 99206 L 0
Valley (509)688-0036 FAX: (509)688-0037
Community Development www.spokanevallev.org
Residential Construction
Permit Application
u ;PERMIT NUMBER: l�
A` PERMIT FEE: 4 ).-5
n New Construction
E Addition/Remodel
n Other:
Accessory Bldg
Deck
SITE ADDRESS x LC
ASSESSORS PARCEL NO: l 5- c 1 > ge2-•
LEGAL DESCRIPTION: R hC.i rb�" kepi Li ei
Building Owner:
Name: Qa.,U cc k She r-[ e PP S• �Y _
Address: 26.23 (V _ Gz ,rvi i_cui.„,ie CIF .
City: C poke Vc - { State: W4 Zip: cj� 206
Phone: 9\ 293- 62-- Fax:
Contact Person
Name: r
Phone: 4'9.) -2 2_
Describe the scope of work in detail:
Contractor:
Name:
Address:
City:
State:
Zip:
Phone:
Fax:
Contractor Lic No:
Exp Date:
City Business Lic. No:
Cost of Project: $ COO
*********x****The fo11owinMUST be complete: (write N/A if not applicable)**"""""""*" """""*"""""
HEIGHT TO PEAK:
PY
DIMENSIONS:
?2`X 2z'
# OF STORIES:
(
TOTAL HABITABLE SPACE:
`f8Y s , .
IMPERVIOUS- SURFACE
AREA:
MAIN FLOOR TQ S
FTG: S 7
2Nu FLOOR SQ. FTG:
qi)-
UNFIN BASEMENT SQ. FTG:
N/A
FINISHED BAS ENT
SQ. FTG: 1V" A
GARAGE SQ. FTG:
!U
DECK/COV, PATIO SQ. FTG:
N/A
30% SLOPES ON
PROPERTY: /VO1t-Q-
# OF BEDROOMS:
%lPt
CONSTRUCTION TYPE:
_St ck 6z? f
HEAT SOURCE:
'- i,e'c ..
SEWER OR SEPTIC?
Sir
The permitee verifies, acknowledges and agrees by their signature that: 1) If this permit is for construction of or on a dwelling, the
dwelling is/will be served by potable water. 2) Ownership of this City of Spokane Valley Permit inure to the property owner. 3) The
signatory is the property owner or has permission to represent the property owner in this transaction. 4) All construction is to be done
in full compliance with the City of Spokane Valley Development Code. Referenced codes are available for review at the City of
Spokane Valley Permit Center. 5) This City of Spokane Valley Permit is not a permit or approval for any violation of federal, state or
local laws, codes or ordinances. 6) Plans or additional information may be required to be submitted, and subsequently approved before
this application can be processed.
c.)'10,,u-7:2,1)(p)h./24...„")_„
Method of Payment:
❑ Cash ❑ Check ❑ Mastercard ❑ VISA
Bankcard #: Expires: VIN#:
Authorized Signature:
REVISED 8/25/2005
Date 5*--,(2--(:)6.
Spokane
Val ley
FOR INSPECTIONS CALL 509-688-0054
YOUR BUILDING INSPECTOR IS:
THIS CARD
Spokanee
_�VaHey
11707 E. Srague Ave
Spokane Valley, WA 99216
Inspection request line (509)688-0054
JAY PRESS3
DOUG PRESS 2
BOB PRESS 1
MUST BE POSTED ON JOB SITE
Job Address
COMMUNITY DEVELOPMENT DEPARTMENT BUILDING DIVISION
/INSPECTION RECORD
PERMIT NO: ricCfJ0gZ3
rl
"AAAA" THIS CARD, PERMIT AND APPROVED PLANS SHALL BE ON JOB SITE AT ALL TIMES*
DATE
INSPECTOR
SETBACKS
FOOTINGS
REINFORCEMENT
UNDERGROUND
RADON
FRAMING
GAS PIPING
DUCT WORK
DATE
INSPECTOR
WATER PIPING
DRAIN / WASTE / VENT
INSULATION
FIREWALL/GWB
FIRE PROTECTION SYSTEM
HVAC SYSTEM
FINAL BUILDING
FIRE
t I
t
0
4
Proposed
Kitchen/
Bathroom
Add it ion
N
E> 1st ing
H
use
2 .0'
Vc
CO
CS)
4 —70.0'
e ci Ave
441.1'
A
Owner: David & Sherrie Peterson
Address: 2623 N. Gary Laurie Ct.
Spokane Valley, WA 99206
(509) 893-8962
Job: Kitchen/Bathroom Addition
Date: Summer 2006
WSEC T A611 6-2
PRESCRIPTIVE REQUIREMENTS°'1 FOR GROUP R OCCUPANCY
CLIMATE ZONE 2
Option
Glazing
%Area'0:
of floor
Glazing U-Factor
pow
U-
Factor
Ceiling2
Vaulted
C
Wali12
Above
Grade
Wall?
Below
Grade
Wall?
Below
Grade
Floors
Slabs
on
Grade
Vertical
Overhead"
I.
10%
0.40
0.58
0.20
R-38
R-30
R-21
int'
R-21
R-12
R-30
R-10
II.
15%
0.40
0.58
0.20
R-38
R-30
R-19+
R-58
R-21
R-12
R-30
R-10
III.
17%
0.37
0.58
0.20
R-38
R-30
R-19+
R-58
R-21
R-12
R-30
R-10
IV.
25%
Group R-1
Occupancy
Only
0.35
0.58
0.20
R-38 /
U=0.031
R-30 /
U=0.034
R-21
int' /
U=0.054
R-15
R-12
R-30 /
U=0.029
R-10 /
F=0.54
V.
Unlimited
0.35
0.58
0.20
R-38
R-30
R-21
R-21
R-12
R-30
R-10
Group R-3
Occupancy
Only
int'
VI.
Unlimited
Group R-1
Occupancy
Only—
0.32
0.58
0.20
R-38 /
U=0.031
R-30 /
U=0.034
R-21
int' /
U=0.054
R-15
R-12
R-30 /
U=0.029
R-10 /
F=0.54
* Reference Case
0. Nominal R-values are for wood frame assemblies only or assemblies built in accordance with
Section 601.1.
1. Minimum requirements for each option listed. For example, if a proposed design has a glazing ratio
to the conditioned floor area of 13%, it shall comply with all of the requirements of the 15% glazing
option (or higher). Proposed designs which cannot meet the specific requirements of a listed option
above may calculate compliance by Chapters 4 or 5 of this Code.
2. Requirement applies to all ceilings except single rafter or joist vaulted ceilings.
3. Requirement applicable only to single rafter or joist vaulted ceilings.
4. Below grade walls shall be insulated either on the exterior to a minimum level of R-10, or on the
interior to the same level as walls above grade. Exterior insulation installed on below grade walls
shall be a water resistant material, manufactured for its intended use, and installed according to the
manufacturer's specifications. See Section 602.2.
5. Floors over crawl spaces or exposed to ambient air conditions.
6. Required slab perimeter insulation shall be a water resistant material, manufactured for its intended
use, and installed according to manufacturer's specifications. See Section 602.4.
7. Int. denotes standard framing 16 inches on center with headers insulated with a minimum of R-5
insulation.
WSEC Builder's Field Guide 5th Edition
COOPERATIVE EXTENSION
WASHINGTON STATE UNIVERSITY
ENERGY PROGRAM
1-7
Owner: David & Sherrie Peterson
Address: 2623 N. Gary Laurie Ct.
Spokane Valley, WA 99206
(509) 893-8962
Job: Kitchen/Bathroom Addition
Dale: Summer 2006
Back of House Fro
ne West , Look TrigEc
st
----------- — --- --- — -- -- — - —
=-------------- - - MAW MI ----"--- — - ---- -- ------ --
- ------------------ ----------------------------
MIMI MN ME IIII ME NM IIIII NI MI =I min III NM IIM UM MI =MEM.. um Ell mu NM ME MI IIII MIME MN IMIAMI IN IIIIIIII_M MI UM MI MI MENEM= MINI MIME MIME IMII
----�MUMII I MNM il---i■1�� i� MI NM rin��NM-r�iiMN—NM-�Z ��-iMEMil�o-�MN
Current
---- r- ---- NM MUM
----NIM M ==== ==---- -----.1�� ----- -------
mum MN IM MUM ME IMIRM 111111 um MI Ell MIMI MN mMll
-NMIMI =I NMI MN ME MINIM IMAM MIMI= MI PP,^
------------- -MEM mm Ell MI NM
-
I I
-- --- mu mu -- ------- --- — ----- r
Min. 4 ft Brace Wall Panel per R602.10.3 & R602.10.4
Min. 2 ft 8 in. Alternate Brace Wall Panel per R602.10.6
Min. 16, 18 or 20 in. APA Portal Frame Bracing
Engineered Shear Wall Bracing
f
JL,II 1111
11
WithNew Additloll
WHEN INTERIOR ALTERATIONS, REPAIRS OR ADDITIONS
REQUIRING A PERMIT OCCUR, OR WHEN ONE OR MORE
SLEEPING ROOMS ARE ADDED OR CREATED IN EXISTING
DWELLINGS, THE DWELLING UNIT SHALL BE PROVIDED
WITH SMOKE ALARMS LOCATED AS REQUIRED FOR NEW
DWELLINGS.
SMOKE ALARMS SHALL BE INTERCON-
NECTED AND HARD WIRED IN SUCH A
MANNER THAT THE ACTIVATION OF ONE
ALARM WILL ACTIVATE ALL ALARMS.
(BEDROOMS, AREAS APPROACHING
BEDROOMS, VAULTED CEILING
WITH RISE OF 24" & ON EACH FLOOR)
--.5 ' 0'
4 3"
-8 ' 3"
DWL IVATE GARAGE HALL HAVE:
PlallirrWENINGETWEEN
1) MATE IIIALS APPROVED FOR ON HOUR FIRE RESISTIVE
CONSTRJCTION ON THE GARAGE IDE:
SiEl" YPE "X" GYP BOARD (HAB TABLE SPACE ABOVE) OR
(11 1./2" 'YP BOARD (RESIDENCE/PTTIC, FLOOF /CEILING)
21 OPEN NGS BETWEEN GARAGE AN) RESIDENCE, SHALL BE
EOUIPPLO WITH SOLID WOOD DOOR, SOLID OR HONEYCOMB COR
STEEL DOORS NOT LESS THAN 1 3/E", OR 20 MINUTE FIRE RATED
DOORS.
' 2"
9 ' 5"
22 ' 0" 3 ,6a
22 ' 0"
zt '
4
QII
8 ' 0"
12 41'
L
3 ' 5"
--NI- 4 ' 6"—
-13
r
EXHAUST FANS
100 CFM kitchen
50 CFM bat,hrooms
& laundry ki.1-rts-
TCV,t.0
C.7.)
2 6 2g
(7)
- (2)
0,
CI)(ID
cti , 00
. a) OD
co
• os
CD
COCNI 5D-ICD
c/D CD
cD
(,)
(/)
ci
521
CD
q=5
30# felt for ice
dam protection
saa
iva.tc,u,tS
-n
ROOF ASSEMBLY
- ATTIC VENTILATION AT 1:300 8Y ROOF
VENTING AND SOFFIT VENTS
- ROOFING MATERIAL AND COLOR TO BE
SPEC'D BY OWNER. (.
JNI' HS N33M �.3t33O# FELT PAFER
-1/2 MIN." APA SHEATHING
JPIall
N
1'-6"
1\ALL SE T O \
1/2" = I'-0"
2623 N Gary Laurie Ct
Spokane, WA 99206
- MANUFACTURED TRUSSES @ 24" O.G.
-R-38 INSULATION BATTS
-6 MIL VAPOR BARRIER OR EQUAL
- 5/8" GYP. BD. WITH PAINTED FINISH.
EXTERIOR WALL ASSEMBLY
-LAP SIDING TO MATCH EXISTING.
-TYVEK BUILDING WRAP
- 1/2" MIN OSB' SHEATHING
- 2X6'S c 16" O.G.
-R- I q INSULATION BATTS
-6 MIL VAPOR BARRIER OR EQUAL.
1/2" GYP. SD. W/ FAINTED FINISH.
N1101.3.1— Attic insulation certification required as to
R — value or coverage. Markers, attached to trusses or
rafters, required for every 300 sf of attic space with 1
inch high numbers for installed thickness of insulation.
FOUNDATION WALL ASSEMBLY
- 2X6 PRESSURE TREATED SILL
- 2" RIGID INSULATION
- PROVIDE SILL SEALER AT TOP OF
FOUNDATION WALL
- GRADE FINISH TO START 6" BELOW TOP OF
FOUNDATION AND SLOPE AWAY FROM
BUILDING. lc,
- 1/2" DIA XA ANCHOR BOLTS a 6'-O" D.G.
OR APPROVED METAL STRAPS ® 4'-0"
- DAMPPROOF CONCRETE WALL PRIOR TO
BACKFILLING.
- REBAR PER LOCAL CODE
EX I ST I NC SU I Liz I ire
•
0
DWLLNGiPROTECTION R)VA' EPGARAGE SHALL HAVE:
1 MATERIALS APPROVED FOR ONE HOUR FIRE RESIS
CONSTRUCTION ON THE GARAGE SIDE:
O 5/B" TYPE "X" GYP BOARD (HABITABLE SPACE ABOVE) OR
O 1/2" GYP BOARD (RESIDENCE/ATTIC, FLOOR/CEILING)
2 OPENINGS BETWEEN GARAGE AND RESIDENCE SHALL BE
EQUIPPED WITH SOLID WOOD DOOR, SOLID OR HONEYCOMB CORE
STEEL DOORS NOT LESS THAN 1 3/8", OR 20 MINUTE FIRE RATED
DOORS.
SPLASH WARD
5,-8"
0
o
11
NEW
A1,1,ITION 4
•
EMERGENCY EGRESS REQUIREMENTS
FROM SLEEPING ROOMS
1) NET CLEAR OPENING: 5.7 SQUARE FEET
GRADE FLOOR OPENING (MAX 44') 5.0 SQUARE FEET
2) NET CLEAR OPENING HEIGHT 24 INCHES
3) NET CLEAR OPENING WIDTH 20 INCHES
4) MAX FINISHED SILL HEIGHT 44" ABOVE FLOOR
5) EMERGENCY ESCAPE &AESCUE OPENING SHALL BE
OPERATIONAL FROM THE INSIDE OF THE ROOM WITHOUT
THE USE OF KEYS OR TOOLS
WHEN INTERIOR ALTERATIONS, REPAIRS OR ADDITIONS
REQUIRING A PERMIT OCCUR. OR 111 EN OR OR MORE
SLEEPING ROOMS ARE ADDED OR CREATED IN EXISTING
DWELLINGS. THE DWELLING UNIT SHALL BE PROVIDED
WITH SMOKE ALARMS LOCATED AS REQUIRED FOR NEW
DWELLINGS.
SMOKE ALARMS SHALL BE INTERCON-
NECTEDAND HARD WIRED IN SUCH A
MANNER THAT THE ACTIVATION OF ONE
ALARM WILL ACTIVATE ALL ALARMS.
(BEDROOMS, AREAS APPROACHING
BEDROOMS, VAULTED CEILING
WITH -RISE OF 24" & ON EACH FLOOR)
E-XI AJST FANS
l k tclhen
59 CI % bathrt i s
&laundry v v-r ,
T '1:s(t a 41—,
Min. 4 ft Brace Wall Panel per R602.10.3 & R602.10.4
Min. 2 ft 8 in. Alternate Brace Wall Panel per R602.10.6
Min. 16, 18 or 20 in. APA Portal Frame Bracing
Engineered Shear Wall Bracing
11
I'
di" MN
i
8'-21"
VERIP`r
`-- RAISE WITH
VENT HOOD AND
VENT.
221-0"
FLOOR PLAN
Scale: 1/4"® 11-0"
L
c
c
FLOOR PLAN
z
0
1-
0
0
0
cc
= O
Z ^Q
*r-
N
GO d< 0)
0CDWM
Za)
M
Iii�a®
QCJ CO
A-1
NEW ADDITION
EXISTING BUILDING
LINE OF GEILIN6
FINISH FLOOR
FINAL GRADE
• •
J
• • J 1 1
2211.
NORTH ELEVATION
SCALE i"= I'-O"
EXISTING BUILDING
NEW ADDITION
•
•
•
• . -[ l •
• J • ■ • . . •
• SIN
• • • • • 1 1 ■•, ▪ • • • ■•■ ■ 1 1 • • 1 . •
• - IN . •
• • • • ■
■ • ■ t•`•• 1 • ■ •. . r►
° 1 ' 1 . • ■ ■• . ■ • 1•' 1 • i '•1 • 1.' 1 ' 1 • ■ ■. . J ' 1 • 1 • . . T•.r l 1 .•. 13
. 1 . 1-.. . 1 . 1 . T ..1 . 1 .-■ . ■ . • ' r ' • 1 1
_. 1 1 . r . 1 r 1 a . ▪ ..• . . ■ . r. • . . . ` . 1 . . • •
. 1
•
• . B • ▪ ' 1 • + ▪ ■ -•
• •i • 11.• J • . ` '. ••i` : • � r •. . r , r . • 7 •-•r -`1..L, • 1 1 .E : �. • ▪ : 3
ti
J . .
r
•. .• '•`
•
•
0
0
■
N ▪ al
1
• • ' i,
WEST ELEVATION
SCALE 4" =11-0"
NEW ADDITION
•
• . 1 • • . . .J. • . . 1 . - J 1 l ■ 1 1
1 1 1 1. 7 i •-
• 1 . J , 1 l . 1 . J r' • r 1 1 . 1 . 1.. . •■ ' 1 1 r • ■ 1 • ■ • • ■ • .•■ r l
■
■ ■ • 1. , ■ • . . i • • J
•
•=• ▪ r. •••.•. • r1
•.
1 l 1 ▪ - r . 1 J
LINE OF GIEILING
WINDOW HEADER HT.
FINISH FLOOR
FINAL GRADE
0
SOUTH ELEVATION
SCALE 4"= I'-o"
EXISTING BUILDING
LINE OF CEILING
WINDOW HEADER HT.
GONG FOUNDATION
FINISH FLOOR
FINAL GRADE
DRAWN BY:
EXTERIOR ELEVATIONS
EX515TIN& BUILDIN6
EX515TIN6 EUILDIN6
SECTION A
Scale: 1/4"=1'-0"
dpi
Scale: 1/4% 1' -0"
NEW ADDITION
oC
tt
w
�
c
a
0
0
m
o
}
°d
va
p
Z
0
—
Q
0
U)
CC
z
�--
z,pa
v
W
Q
Q
N
Co
Z
W
QO
cc
z
z
;5
Cr)
co
L
C\j
Q
00
CL
N
C!)
s.
Iu-tc
MARI ETTA
eAR`r LAURI E GT.
J
18'-O"
12'-6"
SITE PLAN
Scale: 1/8"-1'-0"
�V1 H
rukVH (.1
citV
C.) x �3 3�M*04 sigals
z
w
t--
Z
0
0
0
0
0
cc
to
m
= O
Q L. 9
Z r Q
I
U0cr) rc>"- 4* �
rn
oco
o Za)
w co®0)
O
A-4
EXISTINGSUILIN
FOOTINGS AND FOUNDATION
HALLS HILL TIE INTO THE
EXSISTINS FOUNDATIONS. DOHEL
NEW REBAR INTO EXISTING
FOUNDATION WITH HILT! HIT HY-I50
ADHESIVE A MINIMUM OF 5"
rm. 6" CONC. FOUNDATION HALL
TYP. r-6" GONG . FOOTING WALL
CONCRETE TO COMPLY TO IRC TABLE 404.1.1(1)
FOUNDATION WALLS - 3000 # PSI
SLABS, GARAGES, CARPORTS
& PORCHES - 3500 # PSI
ALL FOOTJNGS MUST BE CONTINUOUS
Minimum depth for frost protection in the City of
Spokane Valley is 24 inches measured from the bottom
of the footing to finish grade. Grade slope away from
building a minimum 6 inches in first 10 feet.
Radon Mitigation System Required
With 6 mil Vapor Barrier
/7"-'--- SLOPE CONC FLOOR Dom
TO Doom. ADDITION
FINISHED FLOOR 1/2" HIGHER
THAN HEST END OF °ARAM
FINISH FLOOR.
11
NEvi
Ar,r,rrioN
4" GONG SLAB OVER
COMPACTED GRAVEL FILL.
RADON MITIGATION SYSTEM
THROUGHOUT ADDITION
r
• • ••••',7*!':,.','• ^ • •• . , ,, z• ; ••.f : t... • 4: •••••:.
221-0"
.3
681-0"
—v 0
0
,t•
LANDING required on both sides ot exit doors with mm. size of 3
ft. measured in direction of travel by 3 ft. or width of door if
•greater, and not lower than 1 V2 in. below threshold. Landing
required at other exterior doors is a minimum size of 3 ft travel
distance by width of door, and not lower than 7 % in. below
threshold provided the door does not swing over the landing.
FOUNDATION PLAN
Scale: 1/4"= 1'-0"
es,
000
m.
0 et,
sl 8g
col A.,-
ip
02
FOUNDATION PLAN
z
0
0
0
cc
co<
u j <
CC -
C.)
I=
<
cv co
(.1) > 0)
u j
0 z CtS
Z CO
Lij Cf) 0
CC?)1 0- C'
o C WV.).
A-5
PROVIDE DIAGRAMS AND
ENGINEERING LAYOUTS FOR
ROOF TRUSSES, BEAMS AND
FLOOR SYSTEMS. PRIOR TO FRAMING
1N`&ECTIONS
E P t} NS ', UST BE KEPT
N THE JOB SITE
THIS BUILDING SU..ECT
TO FIELD INSPECTION CORRECTIONS
REVIEWED FOR CO
SPOKANE VALLEY 13
E COMPLIANCE
LDING p!VISION
ZY 0_`
,eaA.J8