Minimum depth for frost protection in the City of
Spokane Valley is 24 inches measured from the bottom
of the footing to finish grade. Grade slope away from
building a minimum 6 inches in first 10 feet.
Anchor Bolts- Minimum''/" x 10" with 7" concrete
embedment at 6' o.c. and 12" from ends of sill plates.
,uco 4AI:4N SASS
C P to c: h <r+E ','{'- lo of
�xs%'N a/41;1
9me--,5-
Min. 4 ft Brace Wall Panel per R602.10.3 & R602.10.4
Min. 2 ft 8 in. Alternate Brace Wall Panel per R602.10.6
Min. 16, 18 or 20 in. APA Portal Frame Bracing
Engineered Shear Wall Bracing
:
LANDING required on both sides of exit doors with min. size of
3 ft. measured in direction of travel by 3 ft. or width of door if
greater, and not lower than I %z in. below threshold. Landing
required at other exterior doors is a minimum size of 3 ft travel
distance by width of door, and not lower than 7' in. below
threshold provided the door does not swing over the landing.
Figure E
Form TT -073
without hold-downs (For use details see Table 2)