Loading...
2007, 11-06 Permit App 07004336 Pole BldgProject' Number: 07004336 Inv: 1 Application THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Project Information: Permit Use: 30 X 30 POLE BLDG Contact: SKI CONSTRUCTION Address: 4719 E WINFIELD CT C - S - Z: SPOKANE, WA 99021 Setbacks: Front Left: Right: Rear: Phone: (509) 328-3011 Group Name: Site Information: Project Name: Plat Key: Name: OPPORTUNITY 01ST ADD District: Nort Parcel Number: 45172.1410 Block: Lot: SiteAddress: 9703 E BROADWAY AVE Location:: CSV Date: 11/2/2007 Page 1 of 2 Owner: Name: NEAL, R. TERRY Address: 9703 E BROADWAY AVE SPOKANE VALLEY, WA 99206 Zoning: UR-3.5 Urban Residential 3.5 Water District: Hold: Area: 41,153 Sq Ft Width: 0 Depth: 0 Right Of Way (ft): 0 Nbr of Bldgs: 0 Nbr of Dwellings: 0 Review Information: , Review Building Plan Review Released By: Originally Released: 10/30/2007 By: tmelbourn Landuse/Zoning/HE Conditions Released By: Originally Released: 11/1/2007 By: mpalaniuk Operator: JD Printed By: JD Print Date: 11/2/2007 Proj ectNumber: 07004336 Inv: 1 Application THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Contractor: SKI CONSTRUCTION Address: 4719 E WINFIELD MEAD, WA 99201 Building Height 17 Date: 11/2/2007 Building Permit - Firm: SKI CONSTRUCTION Phone: (509) 995-4168 Building Characteristics Description Gar Type Notes POLE BDLG U-1 VB Item Description RESIDENTIAL PERMIT FEE ACCESSORY PLANS REVIEW WSBC SURCHARGE Notes: Payment Summary: Permit Type Building Permit This Application: Total Project: Sq Ft Valuation Su Ft Valuation 900 $17,100.00 900 $17,100.00 Totals: 900 $17,100.00 900 $17,100.00 Units Unit Desc 1 SELECT 1 SELECT 1 SELECT Permit Total Fees: Fee Amount Invoice Amount $371.06 $371.06 $371.06 $371.06 Fee Amount $293.25 $73.31 $4.50 $371.06 Amount Paid Amount Owing $0.00 $371.06 $0.00 $371.06 Page 2 of 2 Disclaimer: Submittal of this application certifies the owner (or person(s) authorized by the owner) has both examined and finds the information contained within to be true and correct, and agrees that all provisions of laws and/or regulations governing this type of work will be complied with. Subsequent issuance of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the code or of any other state or local laws or ordinances. Signature: Operator: JD Printed By: JD Print Date: 11/2/2007 *lane Spokane _Valley Community Development Residential Construction Permit Application Permit Center 11703 E Sprague Ave, Suite B-3 Spokane Valley, WA 99206 (509)688-0036 FAX: (509)688-0037 www.spokanevalley.org PERMIT NUMBER: 1.1�, PERMIT FEE: New Construction n Addition/Remodel n Other: Accessory Bldg Deck SITE ADDRESS: ASSESSORS PARCEL NO: LEGAL DESCRIPTION: Building Owner: Name: ki Address: () -1 v Z) C'i.- '1 61 g City: State: k Zip: Phone: Fax: Contact Person Name: Phone: Describe the scope of work in detail: Proposed Use: Contractor: Name: 1 f i :-X�'� i �-% c3;> C Address: 1 1, 0' I t�`tt= ,, n._ - City: 6 jcitState:) (\ t ^ �'`� Zip: gyozi I Phone:gq ,j ( Fax: Contactor Lic No:1 Exp Date: City Business Lic. No: Cost of Project: $ 60a **************The following MUST be complete: (write N/A if not annlicable)********************** HEIGHT TO PEAK:1 DIMENSI NS: # OF STORIES: 1 1 TOTAL HABITABLE SPACE: MAIN FLOOR TO SQ. FTG: n c__ 2"D FLOOR SQ. FTG: UNFIN BASEMENT SQ. FTG: IMPERVIOUS SURFACE AREA: FINISHED BASEMENT SQ. FTG: GA AGE Q. FTG: 01 DECK/COV. PATIO SQ. FTG: 30% SLOPES ON PROPERTY: # OF BEDROOMS: CONSTRUCTION TYPE: HEAT SOURCE: SEWER OR SEPTIC? The permitee verifies, acknowledges and agrees by their signature that: 1) If this permit is for construction of or on a dwelling, the dwelling is/will be served by potable water. 2) Ownership of this City of Spokane Valley Permit inure to the property owner. 3) The signatory is the property owner or has permission to represent the property owner in this transaction. 4) All construction is to be done in full compliance with the City of Spokane Valley D Spokane Valley Permit Center. This Ci .f local laws, codes or ordina g' 6) Plan this application can be SIGNATURE: Method of Payment: ❑ Cash Bankcard #: ❑ Check ment Code. Referenced codes are available for review at the City of Valley Permit is not a permit or approval for any violation of federal, state or information may be required to be submitted, and subsequently approved before DATE: 10(40i ❑ Mastercard ❑ VISA Expires: VIN#: Authorized Signature: REVISED 2/15/07 Spokane ,Valley. 11703 E Sprague Ave Suite B-3 ♦ Spokane Valley WA 99206 509.688.0036 ♦ Fax: 509.688.0037 ♦ cityhall@spokanevalley.org Residential Plan Submittal Minimums ❑ Completed Building & Mechanical application with: Accurate address, Parcel Number and/or Legal Description, description of work, owner and contractor information, signature, and date. ❑ Two sets of plans including Site Plan, elevations, floor plans, foundation plans With details, roof plan, framing plans & details. ❑ Show the height of any proposed buildings or accessory structures. ❑ Floor plan for each floor: Dimension to scale (minimum 1/8") and label each Room (including sq. footage of house and garage on plans) Show each level of existing house and square footage of any additions. O All braced wall panel types: show locations and details of installation, including engineered design. ❑ Egress windows: Provide at least one window or exterior door approved for Emergency escape or rescue from a basement and in every room for sleeping. O Smoke detector locations ❑ 22" X 30" attic access location O 18" X 24" crawl space access: O One -hour separation detail: between house and garage ❑ Floor framing details: Joist type, size, spacing and installation details O Roof framing plan and details O Furnace and hot water heater location. ❑ All header locations: type, size, and connections ❑ Foundation plan O Insulation information Spokane jUalley For City Use Only PLUS Project Number 0-1 147D Project Address OS F forul - a 11703 E Sprague Ave Suite B-3 • Spokane Valley WA 99206 509.688.0036 • Fax: 509.688.0037 ♦ permitcenter@spokanevalley.org As part of our on -going commitment to customer service during the review process of your project application, we are providing you with a TARGET DATE for the initial technical application review. If for any reason we cannot meet this date, we will contact you with a revised target date. �/07 The TARGET DATE is the date we estimate your project application will have had its initial technical review. It is not the date for approval or permit issuance. Your application review TARGET DATE is Tips for a Smoother Project Application Review ➢ Submit complete, accurate plans and documents. Extra time may be required for re -submittals as project application reviewers work on multiple applications and it may be several days before they can look at your new or revised information. ➢ Designate a specific contact person to communicate with the City. While the person designated as the applicant's contact person with the City can be changed, one individual with the expertise for dealing with reviewer comments would be the best choice for the entire review process. ➢ Call staff regarding the status of your project only after the target date shown at the top of the page. Although you should be contacted on or by the target date, please feel free to contact us if you haven't heard from us by your target date. Staff may contact you before the target date if the initial review is complete. By following this procedure, you will save time and allow the reviewers to complete the work more expeditiously. Steps in the Permit Process 1. Counter Complete. Your application has been accepted as counter complete. This means all of the required documents, as indicated on your Pre -Application Checklist have been submitted or have been approved for deferred submittal. This does not prevent technical staff from requesting additional information as a result of their technical review. 2. Quality Check. The next step in the process is a quality check to make sure that the application is reviewable and free from substantive flaws that would prevent technical staff from completing the technical review once it is started. When this step is complete, your application will be routed to the appropriate staff and remain in their review queue until it comes up for review. 3. Technical Compliance. Once an application is administratively complete, it is routed to technical staff for compliance review. Depending on the type of project, technical staff may include multiple reviewers. You should be contacted by phone, fax, email, or mail by your TARGET DATE once the initial technical compliance review is complete. 4. Permit Issuance. When the technical compliance review of the application is complete, including any subsequent re - submittals, each reviewer will approve their section of the application and route it to the Permit Center. When all sections of the application are received, a Permit Specialist will process the application and contact the person specified on your application for permit pick-up. Information regarding fees and pre -construction meetings (if required) will be provided by the Permit Specialist at that time. WHITE - APPLICANT PINK - BUILDING FILE REV 9/07 WAMBEKE ENGINEERING Daniel Wambeke, P. E. Spokane, WA 99223 2913 East 61' Court Telephone: 509-443-6186 • Fax: 509-448-6582 • dwambeke @msn.com October 20, 2007 Mr. Mike Kaminski SKI CONSTRUCTION 4719 Winfield Court Mead, WA 99021 SUBJECT: 30' X 30' X 12' POST FRAME BUILDING FOR TERRY NEAL, 9703 E. BROADWAY, SPOKANE VALLEY, WA Dear Mike: This post frame building has been sold to Mr. Neal and will be erected according to standard post frame building plans prepared for Ski Construction for 30 & 40 PSF live load, 85 MPH wind speed, Exposure B, Seismic Design Category C and 2,000 PSF allowable soil bearing pressure, IBC 2006. Posts are located 10'0" o. c. and the roof is 4:12 pitch. I have checked the building for the diaphragm design criteria used in the development of the standard plans. The front endwall has two 12' x 12' overhead doors. There is sufficient area of sheeting on this endwall to transfer lateral loads on the roof and sidewalls of this building to the base of the posts. However, it will be necessary to install #12 x 5/8" stitch screws © 9" o. c. to all steel siding vertical side laps — this endwall only. The rear endwall has no openings. There is sufficient steel sheeting on this endwall to transfer lateral loads on the roof and walls to the base of the building. The left sidewall has no openings. The right sidewall has a 3' pass door. Sidewall openings have no effect on the lateral load resistance of the building. You may use the standard post frame building plans for erection of this building. Please feel free to contact me if you have any additional questions about the design of this building. rely, W1W/l (w/t^ Daniel Wambeke, P.E. Enclosure DW:dw EXPIRES edif(v Designer of Small Structures, Post Frame Buildings, Foundations, Cl /0t7-e/ /L 4c_ 2T.' T 2 3 0x 3oxIZ PsT L-44160T c4I , 2--12-uco 120i1 opclevr2- 3 - xr pesTs PornIaa,u.- tZ \/-10 Vd dw- z -p 51 15' 1* fD tD' PLANNING DEPT. AP ---Y s 14/71--t- 1'701 E.