Loading...
2007, 10-05 Permit App 07003972 WindowsProject Number: 07003972 Inv: 1 Application THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Project Information: Permit Use: REPLACING WINDOWS Setbacks: Front Left: Right: Rear: Site Information: Plat Key: 001834 Name: OPPORTUNITY TR # 01-354 Date: 10/5/2007 Page 1 of 2 Contact: WATKINS, WAYNE & LEANNA Address: 3924 N SUNDERLAND CT C - S - Z: SPOKANE, WA 99206 Phone: (509) 000-0000 Group Name: Project Name: District: Nort Parcel Number: 45163.0179 Block: SiteAddress: 11118 E BROADWAY AVE Location:: CSV Zoning: UR-3.5 Water District: Area: 11,136 Sq Ft Urban Residential 3.5 Width: 0 Nbr of Bldgs: 0 Nbr of Dwellings: 0 Review Information: Lot: Owner: Name: WATKINS, WAYNE & LEANNA Address: 3924 N SUNDERLAND CT SPOKANE, WA 99206 Hold: ❑ Depth: 0 Right Of Way (ft): 0 Review Building Plan Review Released By: Originally Released: 10/4/2007 By: TMELBOU Contractor: OWNER Building Permit Firm: OWNER Phone: (000) 000-0000 This Application: Total Project: Description Grp Type Notes Sq Ft Valuation Sq Ft Valuation 1&2 FAMILY R-3 VB REPLACIN 0 $1,100.00 0 $1,100.00 G WINDOWS Item Description RESIDENTIAL PERMIT FEE WSBC SURCHARGE SF PLNS RVW < 7999 SQ FT Totals: 0 $1,100.00 0 $1,100.00 Units Unit Desc I SELECT 1 SELECT 1 SELECT Fee Amount $69.25 $4.50 $27.70 Permit Total Fees: $101.45 Operator: JD Printed By: jmm Print Date: 10/5/2007 Project Number: 07003972 Inv: I Notes: Application THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Payment Summary: Permit Type Building Permit Date: 10/5/2007 Page 2 of 2 Fee Amount Invoice Amount Amount Paid Amount Owing $101.45 $101.45 $0.00 $101.45 $101.45 $101.45 $0.00 $101.45 Disclaimer: Submittal of this application certifies the owner (or person(s) authorized by the owner) has both examined and finds the information contained within to be true and correct, and agrees that all provisions of laws and/or regulations governing this type of work will be complied with. Subsequent issuance of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the code or of any other state or local laws or ordinances. Signature: Operator: JD Printed By: jmm Print Date: 10/5/2007 CITY OI Spokane Valleye Community Development Residential Construction Permit Application Permit Center 11703 E Sprague Ave, Suite B--3 Spokane -Valley, WA 99206 (509)688-0036 FAX: (509)688-0037 www.spokanevalley.org PERMIT NUMBER: PERMIT FEE: New Construction (i Accessory Bldg Addition/Remodel J I Deck Other: SITE ADDRESS: l 111 a E. 'Broad LkThy ASSESSORS PARCEL NO: 45103 • O viziLEGAL DESCRIPTION: OPPORTU NMI PT OF 1310 w $1-CT oc. Building Owner: 1 ' l Name: W 0 , nt W a.-1 i) s Address: 3124 N . SUvtaej,- 14 City: Sp0k.Zvye� State: lJl) A. Zip: 99206 Phone: SOct , flu , 2 asS Fax: Contact Person Name: tovv 4ovveNde I! Sot(1) Phone: 5b % - 5 " 30 g Describe the scope of work in detail: Contractor: OvJ Name: Address: City: State: Zip: Phone: Fax: Contractor Lic No: Exp Date: City Business Lic. No: 0 (c_ 00 Cost of Project: $ 1 100� 7ef1aCtitc. a.v,d Cesiz; widows w;Ht Proposed Use: reSlde-tal. ************** followin IVZUST be complete: (write N/A if not applicable)********************** g # OF STORIES: i TOTAL HABITABLE SPACE: 0.O'f+ Z HEIGHT TOP AK: ��tr DiMENSTONS: , 2 3' X $4 MAIN FLOOR TO SQ. FTG: esU �}2 2NU FLOOR SQ. FTG: NI lA UNFIN BASEMENT SQ. FTG: N Jk IMPERVIOUS SURFACE AREA: IVA.. FINISHED BASEMENT SQ. FTG: N/A- GARAGE SQ. FTG: �A DECK/COV. PATIO SQ. FTG: P/A. 30% SLOPES ON , f PROPERTY: �`' / # OF BEDROOMS: CONSTRUCTION TYPE: ,h il 3 (Z'sew4) w ood-Frawt€ HEAT SOURCE: N /A- SEWER OF SEPTIC? l The permitee verifies, acknowledges and agrees by their signature that: 1) If this permit is for construction of or on a dwelling, the dwelling is/will be served by potable water. 2) Ownership of this City of Spokane Valley Permit inure to the property owner. 3) The signatory is the property owner or has permission to represent the property owner in this transaction. 4) All construction is to be done in full compliance with the City of Spokane Valley Development Code. Referenced codes are available for review at the City of Spokane Valley Permit Center. 5) This City of Spokane' alley Permit is not a permit or approval for any violation of federal, stale or local laws, codes or ordinances. 6) Plans or additional information may be required to be submitted, and subsequently approved before this application can be processed. SIGNATURE: Method of Payment: ❑ Cash Bankcard #: ❑ Check ❑ Mastercard Expires: DATE: y/oZ a/o 7_ ❑ VISA VIN#: Authorized Signature: REVISED 2/15/07 11703 E Sprague Ave Suite B-3 + Spokane Valley WA 99206 509.688.0036 ♦ Fax: 509.688.0037 ♦ cityhall®spokanevalley.org Residential Plan Submittal Minimums ❑ Completed Building & Mechanical application with: Accurate address, Parcel Number and/or Legal Description, description of work, owner and contractor information, signature, and date. ❑ Two sets of plans including Site Plan, elevations, floor plans, foundation plans With details, roof plan, framing plans & details. ❑ Show the height of any proposed buildings or accessory structures. Floor plan for each floor: Dimension to scale (minimum 1/8") and label each Room (including sq. footage of house and garage on plans) Show each level of existing house and square footage of any additions. All braced wall panel types: show locations and details of installation, including engineered design. ❑ Egress windows: Provide at least one window or exterior door approved for Emergency escape or rescue from a basement and in every room for sleeping. ❑ Smoke detector locations ❑ 22" X 30" attic access location ❑ 18" X 24" crawl space access: ❑ One -hour separation detail: between house and garage ❑ Floor framing details: Joist type, size, spacing and installation details ❑ Roof framing plan and details ❑ Furnace and hot water heater location. ❑ All header locations: type, size, and connections ❑ Foundation plan ❑ Insulation information Don Honeydew is my son and is acting as my agent for the purpose of purchasing a buildii g permit for 11118 E. Broadway. Date 2007 s1�u:\%umulI jUalley Project Transmittal City of Spokane Valley Community Development Department 11703 E. Sprague Ave, Suite B3 Spokane Valley, WA 99206 Phone: 509.688.0036 New project' 0 Previous pre-app meeting El Plan revisions Transmittal Date: Thursday, October 04, 2007 Site Address: 11118 E BROADWAY AVE Parcel Number: 45163.0179 Zoning: UR-3.5 Fire District: FD 01 Water District: Project Number: 07003972 Applicant: e-mail: Contact: e-mail: WATKINS, WAYNE & LEANNA 3924 N SUNDERLAND CT SPOKANE, WA 99206 (509) 000-0000 WATKINS, WAYNE & LEANNA 3924 N SUNDERLAND CT SPOKANE, WA 99206 (509) 000-0000 Contractor: OWNER ( ) - 0 Owner: WATKINS, WAYNE & LEANNA 3924 N SUNDERLAND CT SPOKANE, WA 99206 e-mail: Occupant: e-mail: Arch / Engineer: e-mail: Project REPLACING WINDOWS Description: Building Landuse Engineer Utilities Health Fire Dist Assessor APPLICATIO N PLAN S Please send all plan review and project comments via e-mail to the highlighted individuals. 2006 IRC Ten Things You Must Know.!! 1'Zv 5F Sib 1. R105.2 "Work Exempt From Permit" — Spokane County will maintain the 200 sq/ft threshold for one-story detached accessory structures used as tool and storage sheds, or similar uses. 2. Table R301.5 "Live Loads" — Attic storage is clarified in the footnotes of this table. An example: If two or more adjacent trusses with the same web configuration contain a rectangle 42 inches or greater in height by 24 inches or greater in width, located within the plane of the truss, a 2 0 psf ive 1 ad must be applied to the design of the bottom chord components affected. 3. R319.L5 "Exposed Glued -laminated Timbers" — Those portions of glu-lam timbers that form structural support._of buildings/structures and are exposed to the weather, and not protected by a roof, eave, or similar covering shall be pressure treated, or naturally durable wood. 4. WAC AMENDMENT R327 "Protection Against Radon" — State adoption of IRC Appendix F for mitigation measures applicable for buildings constructed in "High Radon Potential Counties" (Spokane county). Appendix F, Section AF101.1 (WAC Amendment) no longer permits un-vented (conditioned) crawl spaces. Appendix F further requires passive radon vents to be installed in vented crawl spaces. WAC Amends R408.2, permitting 1:300 sq/ft ratios for ventilating crawl spaces. 5. R406.1 "Foundation Damp -proofing" — Language change removes "habitable or usable spaces", and replaces with "foundation walls that retain earth and enclose interior spaces and floors below grade..." effectively requiring damp -proofing of crawl space foundation walls. R406.2 similar for water -proofing. 6. R613.2 "Window Sills" — New section requires protection similar to guardrails (4" dia. sphere) for operable portions of windows less than 24 inches above the finished floor, and greater than 72 inches above the adjacent exterior grade or surface below. 7. R702.4.2 Tile Backer Board — Requires cement, fiber -cement, or glass mat gypsum backers for tile installation in tub and shower areas and wall panels in shower areas. 8. R703.2 and Table R703.4 "Water -resistive Barrier" — Felt, or other approved barriers (house wrap) are now required over all exterior wall studs or sheathing, and there is no longer an exception for not requiring such felt/barriers under panel sidings with shiplap joints. 9. R703.8 "Flashing" — The provisions for self -flashing windows (use if the window's mounting flange) has been eliminated. Approved corrosion -resistive fleshings must be applied shingle fashion at all door/window openings. R613.1 requires window manufacturers to provide insta112tion/flashing instructions for each window. 10. Washington State Energy Code Section 505.3 "Outdoor Lighting" — Luminaries providing outdoor lighting and permanently to residential buildings must be high efficiency (compact fluorescent) bulbs with pin style base. Exception allows incandescent fixtures controlled by motion sensors with integral photo sensors. WSEC TABLE 6-2 PRESCRIPTIVE REQUIREMENTS°4 FOR GROUP R OCCUPANCY CLIMATE ZONE 2 Option Glazing Area'D: % of floor Glazing U-Factor Door9 U- Factor Ceiling2 Vaulted Ceiling Wall12 Above Grade Wall? into Below Grade Wall? ext4 Below Grade Floors S6 onb Grade Vertical Overhead" I. 10% 0.40 0.58 0.20 R-38 R-30 R-21 int' R-21 R-12 R-30 R-10 II. 15% 0.40 0.58 0.20 R-38 R-30 R-19+ R-58 R-21 R-12 R-30 R-10 III. 17% 0.37 0.58 0.20 R-38 R-30 R-19+ R-58 R-21 R-12 R-30 R-10 IV. 25% Group R-1 Occupancy Only 0.35 0.5B 0.20 R-38 / U=0.031 R-30 / U=0.034 R-21 int' / U=0.054 R-15 R-12 R-30 / U=0.029 R-10 / F=0.54 V. Unlimited Group R-3 Occupancy Only 0.35 0.58 0.20 R-38 R-30 R-21 int' R-21 R-12 R-30 R-10 VI. Unlimited Group R-1 Occupancy Only 0.32 0.58 0.20 R-38 / U=0.031 R-30 / U=0.034 R-21 int' / U=0.054 R-15 R-12 R-30 / U=0.029 R-10 / F=0.54 * Reference Case 0. Nominal R-values are for wood frame assemblies only or assemblies built in accordance with Section 601.1. 1. Minimum requirements for each option listed. For example, if a proposed design has a glazing ratio to the conditioned floor area of 13%, it shall comply with all of the requirements of the 15% glazing option (or higher). Proposed designs which cannot meet the specific requirements of a listed option above may calculate compliance by Chapters 4 or 5 of this Code. 2. Requirement applies to all ceilings except single rafter or joist vaulted ceilings. 3. Requirement applicable only to single rafter or joist vaulted ceilings. 4. Below grade walls shall be insulated either on the exterior to a minimum level of R-10, or on the interior to the same level as walls above grade. Exterior insulation installed on below grade walls shall be a water resistant material, manufactured for its intended use, and installed according to the manufacturer's specifications. See Section 602.2. 5. Floors over crawl spaces or exposed to ambient air conditions. 6. Required slab perimeter insulation shall be a water resistant material, manufactured for its intended use, and installed according to manufacturer's specifications. See Section 602.4. 7. Int. denotes standard framing 16 inches on center with headers insulated with a minimum of R-5 insulation. WSEC Builder's Field Guide 5th Edition COOPERATIVE EXTENSION WASHINGTON STATE UNIVERSITY ENERGY PROGRAM 1-7 ON SJMP STRAP UPLIFT e 0.. 102- OP- 1,800 POUNDS W VC4) _____ 'IDIIIIIIIII411111nfiNJorule 'e •.ed•e .d•a .4•16-.`"9•a .e6•a d• • ♦ e• ° °. �<. Vie. •. 41 II 111E I'T:101 III Tau -11911111nJ Illtniimrlitt11uP o. - xmaiu1111u11P3fi'ic D . ♦ . p . + . • P • p ••• d • .°6•e ,b•e ,d•e ,d•s .ab'a ,b•e Al. s ♦ d ♦ d TWO ANCHOR BOLTS INSTALLED IN ACCORDANCE WITH FIGURE R403.1(1) SHALL BE PROVIDED IN EACH PANEL. ANCHOR BLOTS SHALL BE PLACED AT PANEL QUARTER POINTS MAX. HEIGHT I0'- 0" ►=-afl➢�IIIII�JtIII!'llullill Ili,�ulOfln;P,l�31 2' 8" MWIDTH 7/16" OSB SHEATHING 3/8" MIN. NAILED WITH Sd COMMON OR GALVINIZED BOX NAILS IN ACCORDANCE',4RTH TABLE R602.3(1) AND BLOCKED AT ALL WOOD STRUCTURAL PANEL SHEATHING EDGES. BACK EACH STRAP WITS] A STUD RECOMMENDED HOLD IN 8" FROM EDGE OF BRACING PANEL I13111IIIIOIIIIII1111111ICIWC111'JIIIIIIIulullg1111u11MIG111. r-=�9117 111111110111111111310.21114111, /111111111111m111N1luN1111N1u111111111 a 1D1111moiP1' _ .ad•e .d'a .d•e .d•e .6.0 .6•a .d•e .d•. .'6•a e e • � 154\R 'f {2 aS01 to NA of Fors WALL IN FIILS•1' STORY OF TWO-STORY BUILDINGS, SHALL HAVE AT LEAST THREE ANCHOR BOLTS, PLACED AT ONE -FIFTH POINTS SIMPSON UPLIFT STRAP 3,000 POUNDS SCALE: 1" = 1'- 0" ERNATE BRACING - PANEL RGoz io 6. i P•602.146 ALTERNATE BRACED IVALL PANELS -r.4 r, 4e f &+-t R602.10.4 Brace Wall Panel min_ 48 in.- 96 in. R602.10.6.1 Alternate Brace Wall Panel min.28in.-42in. R602.10.6.2 Alternate Brace Wall Panel min.l6in.-24in. Engineered Shear Wall Bracing • WHEN INTERIOR ALTERATIONS, REPAIRS OR ADDITIONS REQUIRING A PERMIT , ORHEN ONE OR MORE SLEEPING ROWS A EOCCURADDED OR CREATED IN EXISTING D I N DWELLINGS, THE DWELLING UNIT SHALL BE PROVIDED WITH SMOKE ALARMS LOCATED AS REQUIRED FOR NEW DWELLINGS. SMOKE ALARMS SHALL BE INTERCON- NECTED AND HARD WIRED IN SUCH A MANNER THAT THE ACTIVATION OF. ONE ALARM WILL ACTIVATE ALL ALARMS. (BEDROOMS, AREAS APPROACHING BEDROOMS, VAULTED CEILING WITH RISE OF 24' & ON EACH FLOOR) bAtACE PANEL I T pet..)4s ItA-OuoA1c) sets. oe-rto'- M 1 , 2- Y CAff-GK Oa-- (To g2okbw 40 D IZ-Aw l� 2 ��-a�-"'-..---.i> �y:.�_•�,;.K:.i�=`�'F_.'s�..�-,i�:.w� .. �w.�.a..er.,....._r�.�. .ate `s",'.,�'�-, _ _— pi A 312 b 1TC C 0 5 i Egress windows amenable 5.7 sq. ft. - 44" sill DRAW 1KIC1 - FLOOR ?LAB i l l l 8 E i3Pp c - 22 001-'1--. WALLS ARE. Zx. - STub vJt?LC. S_ A rpR i imI ELL cEICJTE;z . ai 20 Wl 11.15E D E 0a .y f-AC, l ),\J Out T. $ ALL. US fl x S A-gEV f Ng_ LoW E 48" D RAW i 1 48" 84' n>" e ®J a3 2_1E l o (`s)Tap it DPZ 3!, " bIUINC� :4REA/K iTLftE/! EAST wALL TSID5 WALL &2X D. )R v 11\16, Gr wa %'SAC4 >„ R aEPROONi ) A . \ \�//��u2§W&lL i r 3 114.).3 (z) 2.Xi2 PIASTER BATH AR+ J( 4 13EbRoo M - W tST WALL LiV ,coM - 1sST dku_ 2xis 1-1-AD A-S �G4cs nee " i_ PROVIDE DIAGRAMS AND ENGINEERING LAYOUTS FOR ROOF TRUSSES, BEAMS AND FLOOR SYSTEMS PRIOR TO FRAMING INSPECTIONS CITY COPY THIS BUILDING SUBJECT TO FIELD INSPECTION CORRECTIONS REVIEWED FOR CODE COMPLWNCE SPOK,4NE VALLEYiILDI DMSION