2007, 04-30 Permit App 07001523 FoundationPro Project Number: 0 7001 523 Inv: I
Application
THIS IS NOT A PERMIT
Penalties will be assessed for commencing work without a permit
Project Information:
Permit Use: FOUNDATION FOR MFH
Setbacks: Front
Left: Right: Rear:
Site Information:
Plat Key: 001288 Name: HUTCHINSONS ADD
Date: 4/30/2007 Page 1 of 2
Contact: TEEPLES, AUDI
Address: 8523 E BROADWAY AVE
C - S - Z: SPOKANE, WA 99212
Phone: (509) 927-8277
Group Name:
Project Name:
District: Nort
Parcel Number: 45181.1525
Block:
SiteAddress: 8605 E BROADWAY AVE
Location:: CSV
Zoning: UR 3.5
Water District: 005 HUTCHINSON
Lot:
Owner: Name: TEEPLES, AUDI
Address: 8523 E BROADWAY AVE
SPOKANE, WA 99212
Hold: ❑
Area: .00 Acres Width: 62 Depth: 311 Right Of Way (ft): 40
Nbr of Bldgs: 0 Nbr of Dwellings: 1
Review Information: ..
Review
Building Plan Review
Released By:roEj 2��t7
Landuse/Zoning/HE Conditions
Permits:
Released By:
Operator: JD Printed By: JD
Print Date: 4/30/2007
Project Number: 07001523 Inv: 1
Application
THIS IS NOT A PERMIT
Penalties will be assessed for commencing work without a permit
Project Information:
Permit Use: FOUNDATION FOR MFH
Setbacks: Front
Left Right: Rear:
Site Information:
Plat Key: 001288 Name: HUTCHINSONS ADD
Date: 4/30/2007 Page 1 of 2
Contact: TEEPLES, AUDI
Address: 8523 E BROADWAY AVE
C - S - Z: SPOKANE, WA 99212
Phone: (509) 927-8277
Group Name:
Project Name:
Parcel Number: 45181.1525 Block:
SiteAddress: 8605 E BROADWAY AVE
Location:: CSV
Zoning: UR 3.5
Water District: 005 HUTCHINSON
Lot:
District: Nort
Owner: Name: TEEPLES, AUDI
Address: 8523 E BROADWAY AVE
SPOKANE, WA 99212
Hold: ❑
Area: .00 Acres Width: 62 Depth: 311 Right Of Way (ft): 40
Nbr of Bldgs: 0 Nbr of Dwellings: 1
Review Information:
Review
Building Plan Review
Released By:
Landuse/Zoning/HE Conditions
Permits:
Operator: JD Printed By: JD Print Date: 4/30/2007
PLANNING DEPT. APPROVE
BY
DATE: 3' p�-
1
/3ze 176114, a/
3
7 -?
Side, w,//(
Spokane
_Valley
Community Development
Permit Center
11703 E Sprague Ave, Suite B-3
Spokane Valley, WA 99206
(509)688-0036 FAX: (509)688-0037
www.spokanevallev.org
Residential Construction
Permit Application APR EN
7
D
•
PERMIT NUMBER: J5
PERMIT FEE:
Mew Construction Accessory Bldg
Addition/Remodel Deck
Other:k a, O f, c )
ti
SITE ADDRESS: £ e6 C_X-
ASSESSORS PARCEL NO: LEGAL DESCRIPTION:
Building Owner:
/
Name: 9 1 / �., -2 Lp c'
Address: ei 6 (tc, ), r cg ci� ov,
r
City /
69 State: 4.145,
Zip: 9
/--
Phone: s- e9 , a 7 x77 Fax:
Contact Person
Name:
Phone:
Describe the scope of work in detail:
Contractor:
Name:
Address:
City:
State:
Zip:
Phone:
Fax:
Contractor Lic No:
Exp Date:
City Business Lic. No:
Cost of Project: $ CO
Proposed Use: c✓` XS• i ,./l4 a 7(CcC74Cir'-200 /C
**************The following MUST be complete: (write N/A if not applicable)**********************
HEIGHT TO PEAK:
DIMENSIONS:
# OF STORIES:
TOTAL HABITABLE SPACE:
MAIN FLOOR TO SQ.
FTG:
2"" FLOOR SQ. FTG:
UNFIN BASEMENT SQ. FTG:
IMPERVIOUS SURFACE
AREA:
FINISHED BASEMENT
SQ. FTG:
GARAGE SQ. FTG:
DECK/COV. PATIO SQ. FTG:
30% SLOPES ON
PROPERTY:
# OF BEDROOMS:
CONSTRUCTION TYPE:
HEAT SOURCE:
SEWER OR SEPTIC?
The permitee verifies, acknowledges and agrees by their signature that: 1) If this permit is for construction of or on a dwelling, the
dwelling is/will be served by potable water. 2) Ownership of this City of Spokane Valley Permit inure to the property owner. 3) The
signatory is the property owner or has permission to represent the property owner in this transaction. 4) All construction is to be done
in full compliance with the City of Spokane Valley Development Code. Referenced codes are available for review at the City of
Spokane Valley Permit Center. 5) This City of Spokane Valley Permit is not a permit or approval for any violation of federal, state or
local laws, codes or ordinances. 6) Plans or additional information may be required to be submitted, and subsequently approved before
this application can be processed.
SIGNATURE:
ethod of Payment:
Cash
Bankcard #:
Authorized Signature:
REVISED 2/15/07
❑ Check
DATE: 61 e � $ 07
❑ Mastercard ❑ VISA
Expires: VIN#:
Spokane
Valley®
11703 E Sprague Ave Suite B-3 ♦ Spokane Valley WA 99206
509.688.0036 + Fax: 509.688.0037 ♦ cityhall@spokanevalley.org
Residential Plan Submittal Minimums
❑ Completed Building & Mechanical application with: Accurate address, Parcel
Number and/or Legal Description, description of work, owner and contractor
information, signature, and date.
❑ Two sets of plans including Site Plan, elevations, floor plans, foundation plans
With details, roof plan, framing plans & details.
❑ Show the height of any proposed buildings or accessory structures.
❑ Floor plan for each floor: Dimension to scale (minimum 1/8") and label each
Room (including sq. footage of house and garage on plans) Show each
level of existing house and square footage of any additions.
❑ All braced wall panel types: show locations and details of installation, including
engineered design.
❑ Egress windows: Provide at least one window or exterior door approved for
Emergency escape or rescue from a basement and in every room for sleeping.
❑ Smoke detector locations
❑ 22" X 30" attic access location
❑ 18" X 24" crawl space access:
❑ One -hour separation detail: between house and garage
❑ Floor framing details: Joist type, size, spacing and installation details
❑ Roof framing plan and details
❑ Furnace and hot water heater location.
❑ All header locations: type, size, and connections
❑ Foundation plan
❑ Insulation information
City of
SPOKANE VALLEY BUILDING DEPARTMENT
11707 E. Sprague Avenue #1 05, Spokane Valley, Washington 99205 - Tat 509-S83-003o - Fax 509-53S-D037
Framing is a typiJl cross-secfion for a residential garaee. It may not represent the proposed project If you are using the det1
as a porfion of your plan submittal, please complete the requested infonra5on in the boxes provided on both sides of this sheet
This completed sheet, along with arty addi5onal inforrnaEon needs to be subrr ft d with your apli a5on and be an site at the time
of inspec5on.
PROTECTION AND OPENINGS BETWEEN
DWELUNGS AND PRIVATE GARAGES SHALL HAVE:
1) MATERIALS APPROVED FOR ONE HOUR FIRE
RESISTIVE CONSTRUCTION ON THE GARAGE SIDE
' 518' TYPE OC GYP BOARD (HABITABLE SPACE ABOVE)
1/2' GYP BOARD (RESIDENCE/ATTIC, FLOOPJCEIUNG)
2) OPENINGS BETWEEN GARAGE AND RESIDENCE
SHALL BE EQUIPPED WITH SOUD WOOD DOOR, SOLID OR
HONEYCOMB CORE STEEL DOORS NOT LESS THAN 1 318',
OR 20 MINUTE FIRE RATED DOORS.
ALTERNATE FOUNDATION FOR
ACCESSORY BUILDINGS FROM
• 400 SO. FT. TO 3000 SQ. FT.
II =11ftp_
(2)a4 RESAR
SECTION A -A
IIIIOU'
:Iffl 11I1
�11u�
24" MIN.
6" MIN.
24"MIN.
(2) if4 REBAR
NOTE:
Diagonal wall bracing required on
each comer and every 25 feet of wall.
Walls within 3 feet of a property fine or
within 6 feet of a dwelling must be 1 hour
rated. (5/3" type 7X" gypsum sheathing
on both sides of wall). Openings are not
permitted in these walls. Garages over
3,D00 sq. ft require protec5on when
closer than 20 feet to the property One.
Parapets may be required.
ENGINEERED TRUSS OR
RAFTER SIZE AND SPACING
x @ O.C.
ROOFING MATERIAL
ROOFING PAPER.
ROOF
SHEATHING
SOLID BLOCKING
BETWEEN.TRUSSES
WALL SHEATHING
1
SIDING
•
24" MIN. • MIN. ��•`
J
DOUBLE TOP PLATE
WALL HEIGHT
l'v\AtJu FALT'4i
b{eM IAs'rArLL
T� J O
PRESS
SOLE PLATE
3-12" CONCRETE SLAB
•
$"x12"
FOOTING
ANC R BOLTS
112MIN.
(7' INTO CONCRETE)
6' O. G.'OR APPROVED
ANCHOR INSTALLED
PER MANUFACTURER-
FOUNDATION PLAN
PLEASE COMPLETE THE FOLLOWING INFORMATION AND ADD ON THE DRAWING BELOW.
BUILDING DIMENSIONS:
GARAGE OPENING AND HEADER SIZE
INDICATE THE LOCATION AND SIZE OF ALL WINDOWS AND DOORS ON THE PLAN.
WIDTH
1—
CD
z
W
�+... s WSW+
in
R„
4
\..
4
J
LIf
4
REDGE LINE
- - 4-
l l
Under
Floor Ventilation
1 Sq Ft per every50 Sq Ft of und4.
floor space area. 1 ventilating opening shall
be within 3 feet of each corner. Op ings
�.i shall be covered with approved ma rial.
Under floor accessible
by 18" x 24"
CONCRETE TO COMPLY TO IRC T BLE 404.1.1(1)
FOUNDATION WALLS - S000 # /PSI
X
1, ORCHES 3500 # PS
SGARAGES, CARPORT
ALL FOOTINGS MUST BE CONTINUuti`}
v1it.! ! .J8 C I!-H
1
4,11
A
1
Please note that while every effort is made to assure the accuracy of the information contained in this brochure is
not warranted for accuracy. This document is not intended to address all aspects or regulatory requirements for a
project and should serve as a starting point for your investigation. For detailed information on a particular project,
permit, or code requirement refer directly to applicable file and/or code/regulatory documents or contact the
appropriate division.
CITY COPY
THIS BUILDING SUBJECT
TO FIELD INSPECTION CORRECTIONS
Hey
REVIEWED FOR CODE COMPLIANCE
SPOKANE VALLEY BLJttDIDIVISION
l