2012, 05-15 Permit SW-12001340 SewerSPOKANE COUNTY BUILDING AND PLANNING
PERM T
Application Number: SW-12001340
Permit Issued Date:
05/15/2012
Expiration Date:
Project Description: SEWER CONNECTION
Project Name: WEATHERWOOD
Permit Type: SEWER
Primary Contact: PIERSOL CONSTRUCTION INC
Applicant: PIERSOL CONSTRUCTION INC
Address: 2233 S GARFIELD RD
AIRWAY HEIGHTS, WA 99001
Phone: 509-535-2901
Email:
SITE INFORMATION:
Site Address:
Parcel Number:
13810 E BROADWAY AVE
45154.0103
Subdivision: FERREL'S SUBDIVISION
Assessor's Description: VERA FERRELS B115 L2
Inspection Area:
Owner: EVERGREEN 711 INC
Address: 12209 E MISSION STE 5
SPOKANE VALLEY, WA 99206
Phone:
Email:
Water District: Vera Fire District: Fire District 1
Irrigation District #15
Zoning: Land Area: 0.4144 acres / 18050 sqft
CONTRACTOR INFORMATION:
General Contractor
PERSCI055OQ
*PIERSOL CONSTRUCTION INC
2233 S GARFIELD RD
AIRWAY HEIGHTS, WA 99001
509-535-2901
DETAILS:
Class
Type
Quantity Unit Charge Value
SEWER ABANDONMENT 1 $125.00 $125.00
FEE DETAIL:
Processing - Utilities
Utilities Permit
Total Fee:
$125.00
$25.94
$125.00
$150.94
CONDITIONS:
CALL 1-800-424-5555 BEFORE YOU DIG --AT LEAST 2 WORKING DAYS IN ADVANCE. SPOKANE COUNTY CODE REQUIRES THE
INSTALLER COMPLY WITH ALL REQUIREMENTS OF THE WA STATE DEPT OF LABOR & INDUSTRIES, INCLUDING THOSE
RELATED TO TRENCH SAFETY.
FOR SEWER INSPECTIONS CALL THE UTILITIES DEPT AT (509) 477-3604 FROM 8:30-5:00 MONDAY-FRIDAY PRIOR TO COVER.
ONE WORKING DAY NOTICE REQUIRED. PERMIT ALLOWS FOR A 30-MINUTE INSPECTION. ADDITIONAL INSPECTION FEES
APPLY AFTER 30 MINUTES.
Date Printed: 05/15/2012 11:19:59
Printed by: IIS APPPOOLIASP.NET v4.0
SPOKANE COUNTY BUILDING AND PLANNING
PE ..MiT
Permit Issued Date:
Application Number: SW-12001340 05/15/2012
Expiration Date:
INSTALLER IS RESPONSIBLE TO INSURE ALL WASTEWATER DRAINS ARE CONNECTED TO THE SEWER AND MAY BE REQUIRED
TO PERFORM TESTS FOR VERIFICATION. INSTALLER IS TO FIELD LOCATE AND CONFIRM THE ELEVATION AND POSITION OF
SEWER STUB PRIOR TO ANY OTHER EXCAVATION.
SEWER STUBS AND DRY SIDE SEWERS ARE TO BE CHECKED PRIOR TO CONNECTION TO ENSURE THAT THEY HAVE
ACCEPTABLE GRADE AND ARE CLEAR AND UNOBSTRUCTED. SEWER LINES SHOULD BE CONSTRUCTED TO ALLOW FOR
GRAVITY FLOW FROM THE LOWEST LEVEL OF THE STRUCTURE.
THE INSTALLER AND THIS PERMIT MUST BE PRESENT AT THE JOB SITE AT THE SCHEDULED INSPECTION TIME. BOTH STATE
LAW RCW 19.122 AND COUNTY CODE REQUIRES THE INSTALLER TO GIVE NOTICE OF EXCAVATION TO OWNERS OF
UNDERGROUND FACILITIES.
Date Printed: 05/15/2012 11:19:59
Printed by: IIS APPPOOLIASP.NET v4.0