Loading...
1995, 01-23 Permit App 95000356 RemodelPROJECT NUMBER= 95000356 APPLICATION DATE= 01/23/95 PAGE= 01 ****** THIS IS NOT A PERMIT ****** PENALTIES WILL BE ASSESSED FOR COMMENCING WORK WITHOUT A PERMIT SITE STREET= 14712 E BROADWAY AVE ADDRESS= SPOKANE WA 99216 PARCEL#= 45144.0630 pN4�j12l7 g 27*-) 71/9L. )aACIlJTV PERMIT USE= CHANGE OF USE (RESIDENCE/EL Y-CARE) /REMODEL cy a 4%10 c ee.7"4.1-4 PLAT#= 001271 BLOCK= 52 AREA= 00000000 # OF BLDGS= 1 PLAT NAME= LOT= F/A= DWELLINGS= OWNER= SMITH, SCOTT STREET= 14712 E BROADWAY AVE ADDRESS= SPOKANE WA 99216 HOODS SUB ZONE= UR 3.5 DIST#= F WIDTH= 90 DEPTH= 1 WATER DIST = VERA F 150 R/W= PHONE= 509 922 6168 CONTACT NAME= SCOTT SMITH PHONE NUMBER= 509 922 6168 BUILDING SETBACKS: FRONT= EXIS LEFT= EXIS RIGHT= EXIS REAR= EXIS ****************************** REVIEW INFORMATION ***************************** DEPARTMENT BUILDING COMMENTS: BUILDING COMMENTS: BUILDING COMMENTS: T E INEER 1416 COMMENTS: REVIEW REQUIREMENT REVIEW COORDINATOR PLAN REVIEW REQU OTHER:; ED DOMPIE SITE DRAINAGE TO BE REVIEWED ;L.L.HC'G/6 HEALTHDIST INCREASE IN LOT COVERAGE COMMENTS: Ah PLANNING INAPPROPRIATE USE WITHIN ZONE COMMENTS: 6rW4-11-' L k\gP ,1 p/..7. bk& / ot %,;(5161 Ld ,,e4/ 04,/,” /g PROJECT NUMBER= 95000356 APPLICATION DATE= 01/23/95 PAGE= 02 ******************************* BUILDING PERMIT ******************************* CONTRACTOR= OWNER PHONE= NEW= REMODEL= X ADDITION= CHANGE OF USE= DWELL UNITS= 1 OCCUP. LD= BLDG HGT= STORIES= BLDG W X D = X SQ FT= SPRINKLER= N REQ PARKING= #HANDICAP= CRITICAL MAT= N DESCRIPTION GROUP TYPE SQ FT VALUATION REMODEL R-3 VN 2000.00 ITEM DESCRIPTION QUANTITY FEE AMOUNT RESIDENTIAL VALUATION Y 45.00 STATE SURCHARGE Y 4.50 RESIDENTIAL SURCHARGE Y 8.10 PLNG-PERMIT REVIEW; 119 Y 22.00 ******************************* MECHANICAL PERMIT ***************************** CONTRACTOR= OWNER PHONE= ***************************** PLUMBING PERMIT ****************************** CONTRACTOR= OWNER PHONE= PERMIT TYPE FEE AMOUNT AMOUNT PAID AMOUNT OWING BUILDING PERMIT 79.60 .00 79.60 79.60 PROCESSED BY: DAWN DOMPIER PRINTED BY: DAWN DOMPIER .00 79.60 ******************************** THANK YOU ************************************ ACTION: R SCREEN: NOAD USERID: MSTI H- BUILDING PERMIT SYSTEM NOTES BY ADDRESS JURISDICTION= 11 NAME DIR NUMBER SUB TYPE APT LOC BROADWAY E 014712 AVE SPO DEPT= 1000 TOPIC= CONDITIONS LINE DESCRIPTION 01- 01 00 WE HAVE NO KNOWLEDGE OF EXISTING ELDERLY CARE. NO INFOR- 02- 02 00 MATION IN FILES ON OCCUPANCY. WE WILL NEED SITE PLAN PRIOR 03- 03 00 TO RELEASE OF PERMIT ALSO A FIELD INSPECTION WILL BE RE- 04- 04 00 QUIRED PRIOR TO RELEASE OF PERMIT. 05- 06- 07- 08- 09- 10- 05-*L009 HEADER CHANGE :JATTSUUN 5..4 1991 WA STATE ENERGY CODE COMPLIANCE REPORT FILE: C:\\WATTDATA\\SMITHADD.WS HOUSE ID: 01/25/95 Smith Addition Site: meowner: Scott Smith Builder: Spokane, WA ( ) - (509 )922-6168 Analyst: Jurisdiction: Utility: TAS Spokane WWP County House Type: Single Family Floor Area: 629 ft2 Weather Data: Spokane, WA Climate Zone: 2 The PROPOSED design *COMPLIES* with 1991 ,COMPONENT PERFORMANCE ENERGY BUDGET WA State Energy Code. REFERENCE 141 9.28 PROPOSED 138 Btu/hr-F 10.27 kWh/ft2-yr 2EFERENCE DESIGN Component Reference Value X Area = UA Floor Glazing @15% Doors AG 6Ja11 Ceiling, Vault Infiltration U-0.029 U-0.600 U-0.400 U-0.062 U-0.034 ACH-0.350 629 94.3 21.0 593 629 5661ft3( 18.2 56.6 8.4 36.7 21.4 34.3) Reference UA 141 DROPOSED DESIGN COMPONENTS Component Description BG Wall BG Slab Floor Glazing P4% Doors AG Wall Ceiling R11 Batt 7' depth R30 vented Joist 16oc �:*2 glaze vinyl 3/4" air space Metal 1-3/4" urethane flush **6" CMU w/ 1 1/2" Fur'g & 1' Blkore R19 batt Vault vented 2x10 24oc Value U-0.051 F-0.541 U-0.029 U-0.500 U-0.140 U-0.110 U-0.048 X Area = UA 0 Oft 629 28.0 21.0 659 629 0.0 0.0 18.2 14.0 2.9 72.5 30.2 stems in parentheses not included in COMPONENT PERFORMANCE totals. +* Denotes non-standard values - check calculation of thermal value. --- Page 1 1ATTSUN 5.4 1991 WA STATE ENERGY CODE COMPLIANCE REPORT 01/25/95 "rILE: C:\\WATTDATA\\SMITHADD.WS HOUSE ID: Smith Addition Infiltration Standard Air Sealing ACH-0.350 5661ft3 ( 34.3) Proposed UA 138 Struc Mass Slab w/No cover, Sheetrock walls M-10.000 629 6290 1EATING/COOLING/VENTILATING SYSTEMS Heating System Type: Make: Model: PROPOSED Gas Furnace unknown/ unknown/ System Efficiency: 78 % Modified Efficiency: 61 Design ACH: Design Load(at 66F dt): Duct Losses(% Dsn Load): Total Load: System Size: 0.60 13365 Btu/hr 3242 Btu/hr(24%) 16607 Btu/hr 25000 Btu/hr (150%) Average Annual Heat: 29 MBtu Annual Cost: $ 161 Ventilation System: Integrated w/Forced Air Furnace Cooling System: SEER:, tooling Load(at 12F dt): System Size(%Over): tnnual Cool Requirement: 0.0 (Ducted) 7555 Btu/hr 0.9 tons(@125%) *** kWh/yr Solar Access: Partially. Shaded T 'ROPOSED DUCT SYSTEM Location Avg Rvalue Surface Area SUPPLY RETURN Vented crawlspace R- 8.0 Attic or garage R- 8.0 125.8 ft2 25.2 ft2 Page 2 JATTSUN 5.4 1991 WA STATE ENERGY CODE COMPLIANCE REPORT 01/25/95 'ILE: C:V\WATTDATA\\SMITHADD.WS HOUSE ID: Smith Addition ------------------ LAZING ORIENTATION PROPOSED PROPOSED South - ft2 North ft2 Southeast : Northwest : East West 28.0 Northeast : Southwest : 'Economic and energy consumption estimates are designed for comparative purposes only. Actual cost for heating will vary depending on weather .onditions, occupant lifestyle and other factors. ---- Page 3 -- PLUMBING PERMIT APPLICATION PROJECT ADDRESS: Er OWNER:°"' ) (kc MAILING ADDRESS: Rs •nt,rtiTh fPHONE: � c� b ( C CONTRACTOR: MAILING ADDRESS: Se Fi E HA (street) )6raoif (street (city/state) (zip) LICENSE: PHONE: 47 c (city/state) (zip) PLUMBING FIXTURES DESCRIPTION DETAIL # OF UNITS uu n- PLIED By COST /UNIT Balms AMOUNT 1302 TOILETS WATER CLOSETS BIDETS X $6 = $ B03 URINALS - x $6 = $ B04 TUBS H, BATJACUZZI SPA, GARDEN (co, \ ' I x $6 = $ BOS SHOWERS (per trap) BASE. STALL, ON—SITEBUILD '-`." I x $6 = $ B06 SINKS LAVS/BASINS. BAR, FLOOR, KITCHEN, LAUNDRY, UTILITY, JANITOR, PHOTO, X—RAY. FOOD (PREP/CULINARY/MEAT) ' X $6 = $ B07 DISHWASHER - x $6 = $ B08 CLOTHES WASHER - x $6 = $ B09 GARBAGE DISPOSAL/GRINDER - x $6 = $ B10 - x $6 = $ WATER SOFTENER B1I ELECTRIC HOT WATER TANKS (NOTE: if ps water tank, see mechanical) X $6 = $ B12 FLOOR DRAINS AREA, CASE, COIL,TRENCIL CONDENSATE x $6 = $ B13 ROOF DRAINS/OVERFLOW DRAINS (ea.) - x $6 = $ B14 FOUNTAINS, DRINKING - x $6 = $ B15 ,ssI WATER PIPING/DRAIN-WASTE-VENT/ PLUMBING REVERSALS INSTALLATION, ALTERATION, REPAIR, REVERSALS X $6 = $ B16 GRINDER, SUMP PUMP X $6 = $ SEWAGE EJECTORS B17 WATER USING DEVICES ICE AND/OR COFFEE MAKER, HOSE BIB. STEAMER, PROOFER, CARBONATOR, SWAMP COOLERS X $6 = $ 13 8 CROSS -CONNECTION DEVICES VACIUM BREAKER,CIIECK VALVE. AND R.P.B.P.D. FOR: VATS SUMPS. TANKS, BOILERS, & SPRINKLER SYSTEMS x $6 = $ B19INTERCEPTORS GREASE TRAP, SAND TRAP. CHEMICAL HOLDING TANK x $6 = $ B20 MEDICAL GAS (per outlet/bottle station) NITROUS. OXYGEN X $6 = $ B21 MISCELLANEOUS FIXTURES x $6 = $ Spokane NOTE: MINIMUMPERMIT v' SIGNATURE: °' FEE IS $35.00 Subtotal PLUS: PROCESSING $25.00 FEE TOTAL PERMIT FEE DUE $ County Division of Buildings A c ' S okane WA 99260 PLEASE SPOKANE - MAKE CHECKS PAYABLE TO CENTER COUNTY PERMIT - - I026 W. Broadway vertu p , Tel. No. (509) 456-3675 • Fax No. (509) 456-4703 • TDD No. (509) 324-3166 1MASTERWLVMPMAFIND MECHANICAL PERMIT APPLICATION PROJECT ADDRESS: SQ l''t' ?/,) grocer (! Cdir OWNER: kj � 11' t s a4 �J `l r> s� rnii✓; 1 t (i /\ PHONE: 9 ,.7). -6 ( c, s MAILING ADDRESS: E „ / (2 AQ' GO eco S p66,Er t & (street) (city/state) (zip) CONTRACTOR: LICENSE: PHONE: MAILING ADDRESS: - 1 1 (Pc ,. - (street) Cr.t< (city/state) 9 pa.,-6 (zip) DESCRIPTION OF WORK # OF UNITS MULTI- MAMMY COST /UNIT soon., AMOUNT B02 FUEL BURNING APPLIANCE = or <100,000 $12 - , B03- FUEL BURNING APPLIANCE >100,000 , $15 - , B04 UNLISTED APPLIANCE (ADDITIONAL CHARGE) = or <400,000 . $50 - , 1305 >400,000 $100 - $ UNLISTED APPLIANCE (ADDITIONAL CHARGE) B06'i USED APPLIANCE (Must meet WSEC's min. AFUE rating) = or <400,000 $50 - , B07 USED APPLIANCE (Must meet WSEC's min. AFUE rating) >400,000 , $100 - , 1308' BOILER/REFRIGERATION 1—IOOMBTU , $12 - , B09: BOILER/REFRIGERATION 101-500M BTU , $20 - , P10 BOILER/REFRIGERATION 501-1,000M BTU $25 1311: BOILER/REFRIGERATION I,001-1,750M BTU $35 - B12` BOILER/REFRIGERATION +1,75OMBTU , $60 - , B13" GAS LOG, GAS INSERT, AND/OR GAS FIREPLACE - $10 - , B14- RANGE - $10 _ , B15'. DRYER - $10 - , B16':FUEL BURNING WA1LRHEA1ER - . $10 - , B17-MISCELLANEOUS FUEL BURNING APPLIANCE - . $10 - 13I8' GAS PIPING (ea. outlet) - $1 _ , B19' - $10 - DUCT SYSTEMS 1320 VENTILATING FANS - , $10 - B21':' AIR HANDLER (DOES NOT include duct systems) = or <10 000 CFM $12 B22' AIR HANDLER (DOES NOT include duct systems) >I0,000 CFM $15 - 1323 EVAPORATIVE COOLERS - $10 - , 1324` TYPE I HOOD - , $50 - , B25: TYPE II HOOD - , $10 - B26 HEAT PUMP/AIR CONDITIONER 0-5TONS $12 B27 AIR CONDITIONER 6-15 TONS , $20 - B28. AIR CONDITIONER 16-30 TONS $25 B29' AIR CONDITIONER 31-50TONS $35 B3tJ AIR CONDITIONER +50TONS , $60 B31':. LPG STORAGE TANK - , $10 B32 : WOOD OR PEI 1 FT STOVE/INSERT - $25 - Spokane 1026 NOTE: MINIMUM PERMIT FEE IS $35.00 ( SIGNATURE: (f✓ ("1'% " Subtotal PLUS: PROCESSING FEE $25.00 TOTAL PERMIT $ FEE DUE County Division of Buildings W. Broadway ` Spokane, WA 99260 PLEASE MAKE CHECKS PAYABLE TO: COUNTY PERMIT CENTER SPOKANE Tc1. No. (509) 456-3675 * Fax No. (509) 456-4703 ` TDD No. (509) 324-3166 mas le r\mechperm.hnd APPLICATION INFORMATION Parcel number / qm. 956.39. SITE ADDRESS � ` ? J r 'r!"a ace / 4—, Legal (cnptio /,�r C 1�Lit j. )—o Ls J ci b 1 tf 6 S t. l"14 Propertytsi Zone Water district lnspector;district NER 1A11► A ress L , C O-laL 8vzxpa APPLICANT Address CONTACT Cs, PERMIT USE Right of way width gc--o CJ fc4. 4 ro I'jyl O s►'vv. Phone cN.O — 10 f 1d0 Cit ,state V'4 Phone Zipg9a. l� City, state Zip Phone ! ata Building Contractor License st-C New _ Change of use)` Add Remodel, Building height Dimensions,/X I`9 Address }- 7 ab6016t6 y Architect/Engine/, /r /(J� coon Manufadtured Home Value i floor SecoTtd floor <r Stories Total fQotT+,2 Unfini e basement Finished basement Zcks, etc. Jsarage ���tndcl� 1 a"acaovcr Sign Width: Length: Square footage Height Year: Make: Contractor Contractor License License Address Address City, state, zip City, state, zip DCI.rI.-....-+... JJgELJ&0 A o� cL rc *e 6 i a s w'I-- P'l OD (a v )umber ©-�` oCCyc License Address City, state, zip Safety Fire Sprinkler Tent _. nt booth _ Fire Alarm Fireworks display ;tor s ate, zip mming Pool gallons Private Public/semi-private :tor License Address City, state, zip 6' BR❑ADWAY AVE E WATER MAIN • 27' 2 '-11 31'-10N DRIVEWAY 23'-10" SIDEWALK 90' WATER LINE RAMP SIDEWALK PRESENT GARAGE ',PROPOSED NEW ADDITI❑N 20'-4• FRONT PORCH MAIN HOUSE 25'-2" 21'-10" z o 36'-5" 78' 57'-8" i U) BACK MQORCH +1118 30'-6" 4 277 5" 0 E, 14712 BR❑ADWAY LEGAL LOT INFORMATION PLAT# 001271 BLOCK 52 ZONE UR 3,5 PLAT NAME, HOODS SUBDIVI❑N VERADALE WATER DIST. NOTE. HOUSE HAS 1705 SO.FT. NO OUTSIDE DIK OF HOUSE IS BEING CHANGED SCALE: 1" = 180" OR 15' 12'-9" STORAGE STAIRS '- DOWN LAUNDRY ROOM 2 2' -}- 21' -11 " STORAGE RECREATION ROOM FIREPLACE i CLOSET BATHROOM 56'-7" CLOSET TV ROOM 24'-7" 14 e tr h 111 NORTH SCALE:1' = 72' 311-10" SITTING ROOM BATHROOM CLOSET CLOSET CLOSE1 SEWING ROOM HALL 12'-9" - 22' DININGR❑❑M L LIVINGRD❑M CLOSET FIREPLACE L L STAIRS 1 DOVN HALL SLIDING BACK DOOR KICHEN BEDROOM j CI w c� I I 77'-6" U 56'-7" Nal FRONT DOOR 21'-11" CLOSET L— L_ HALL CLOSE I BATHROOM I I Iol ±J__ J r BEDROOM BEDROOM NOTE: HOUSE HAS 1705 SQ,FT. NO OUTSIDE DIM. OF HOUSE IS BEING CHANGED 24'-7" SCALE:1' = 72' x f 1 0 L 1 MIRTH X STEP DOVN SCALE: 1" = 36" SPOKANE COUNTY DEPARTMENT OF BUILDINGS WEST 1026 BROADWAY • SPOKANE, WA 99260-0050 (509) 456-3675 SITE INFORMATION PROJECT INFORMATION r SITE ADDRESS: 14712 E BROADWAY AVE SPOKANE WA 99216 PARCEL NUMBER: 45144.0630 SUBDIVISION: HOODS SUB LOT: BLOCK: 52 ZONE: UR 3.5 INSPECTOR: REED OCKEY WATER DIST: VERA OWNER: SMITH, SCOTT PHONE: 509 922 6168 ADDRESS: 14712 E BROADWAY AVE SPOKANE WA 99216 PROJECT NUMBER: 95000356 ISSUE DATE: 01/27/95 PERMIT USE: REMODEL RESIDENCE/ADULT APPLICANT: SMITH, SCOTT PHONE: 509 922 6168 ADDRESS: 14712 E BROADWAY AVE SPOKANE WA 99216 FAMILY HOME (8 OR LESS OCCU CONTACT: SCOTT SMITH PHONE: 509 922 6168 SETBACKS -> FRONT: EXIS LEFT: EXIS RIGHT: EXIS REAR: EXIS LENDER NAME: PHONE: ADDRESS: PERMIT(S) BUILDING PERMIT CONTRACTOR OWNER LICENSE #: REMODEL DIM.= X STORIES SQ FT = REMODEL R-3 VN TOTAL VALUE: $2,000.00 RESIDENTIAL VALUATION 45.00 STATE SURCHARGE 4.50 RESIDENTIAL SURCHARGE 8.10 PLNG-PERMIT REVIEW; 11 22.00 TOTAL PERMIT FEE $79.60 PAYMENT SUMMARY NOTES PAYMENT DATE RECEIPT# PAYMENT AMOUNT 01/27/95 00000603 TOTAL FEES $79.60 AMOUNT PAID AMOUNT OWING $79.60 $79.60 $.00 ISSUED PERMIT BY: DAWN DOMPIER NOTICE It is the responsibility of the permittee, not Spokane County, to see to it that the use described on the front of this permit complies with applicable codes and requirements and that required inspections are requested. Failure to request required inspections and obtain the necessary approvals prior to progressing beyond the point where inspections are required may necessitate removal of certain parts of the construction at the owner's/permittee's expense. At a minimum, the following inspections ARE REQUIRED by County Code: 1. FOOTING - when forms and reinforcement are in place and prior to placement of concrete. NOTE: This inspection includes review of the structure's setbacks from property lines. Minimum setbacks are established by County zoning regulations. Typically, side and rear yard setbacks are measured from property lines, while setbacks for yards abutting streets are measured from the property line or the center line of the roadway right-of-way, whichever provides the greater setback from the center line of the roadway right-of-way. Curb lines and fence lines are not necessarily indicative of property lines. In some residential areas, the County can own as much as 20 feet of right-of-way between your property and the actual improved street/curb. The responsibility to comply with applicable setback provisions lies solely with the permittee —neither Spokane County nor its authorized representatives assume any responsibility for the verification or location of your property lines. Please verify their location prior to locating your structure. Failure to properly locate the structure may require its relocation at the owner's/permittee's expense. 2. FOUNDATION - when forms and reinforcement are in place and prior to placement of concrete. (Blocking for a manufactured home is required to be inspected prior to the installation of skirting.) 3. FRAMING - after all framing, bracing and blocking is in place, and prior to concealing. 4. INSULATION - prior to the installation of drywall- 5. PLUMBING - after rough -in, before covering, and final. 6. MECHANICAL - rough -in of piping, before covering, metal chimneys before concealment, and final. 7. FINAL - when complete and prior to occupancy and/or use. Please provide 24 hours notice. NOTE: In addition to inspection of the structure, this inspection includes review of site improvements (typically depicted on the approved site plan) required by ordinance or as a condition of approval of this permit. Items such as the installation of fire hydrants, fire department access, on -site drainage ("208 swales"), road improvements, parking, and landscaping are common requirements of a permit/site plan which must be completed prior to final approval of a building or issuance of a Certificate of Occupancy. In addition to the above any plumbing or mechanical systems or materials which would be concealed by framing, drywall, concrete, etc., must be inspected prior to cover. Check with the department for "special inspections" in conjunction with commercial projects. CALL 456-3675 FOR INSPECTIONS. TO INSURE PROMPT SERVICE, PLEASE GIVE 24 HOUR NOTICE. YOUR INSPECTOR IS UNDER CERTAIN CIRCUMSTANCES, PARTS OF YOUR PROJECT MAY REQUIRE INSPECTIONS FROM OTHER AGENCIES: • Road cuts for utilities or drives, County Engineer's Office • Sewer connection, County Utilities Department 456-3600 456-3604 or State Department of Transportation or City Public Works Department 456-3000 625-6300 • On -site waste disposal system, Spokane County Health District Electrical wiring, State Department of Labor and Industries 324-2640 324-1560 • Construction in a flood plain, County Engineer's Office 456-3600 EXPIRATION Unless otherwise noted, this permit will be considered null and void by limitation of the work authorized by the permit if not commenced or is stopped for a period of 180 days, unless a written request for an extension of the permit is received and approved by the Building Official prior to expiration. At a minimum an inspection should be requested at least once every 180 days to assure the validity of the permit. A permit may be renewed within one year of the date of expiration for one-half the original fee, subject to certain limitations —please call us if you have any questions. MISTAKES? If you think we've made an error in processing this permit or in conducting inspections pertaining to it, or find erroneous information in the permit, please bring it to our attention immediately by filing a written request for correction within 10 working days of discovery. All such requests should be directed to the Department of Buildings at the address found on the face of this permit. certify that I have examined this permit/application, state that the information contained in it and submitted by me or my agent to compile said\ permit/application is true and correct, and authorize Spokane County to proceed with processing. In addition, I have read and understand the INSPECTION REQUIREMENTS/NOTICE provisions included herein and agree to comply with same. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. 1 understand that the issuance of this permit/application and any subsequent inspection approvals or Certificates of Occupancy shall not be construed to give authority to violate or cancel the provisions of any state or local law regulating construction, or as a warranty of conformance with the provisions of any state or local laws regulating construction. SIGNATURE OF APPLICATION OWNER OR AGENT DATE J