Loading...
2007, 10-25 Permit App 07004245 DeckProject Number: 07004245 Inv: 1 Application THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Project Information: Permit Use: DECK W/HANDICAP RAMP Setbacks: Front Site Information: Plat Key: Left: Right: Rear: Name: MURBACHS SUB Date: 10/25/2007 Page 1 of 2 Contact: YAGER, RICHARD A & JOYCE A Address: 15318 E BROADWAY AVE C - S - Z: VERADALE, WA 99037 Phone: (509) 000-0000 Group Name: Project Name: District: East Parcel Number: 45144.0105 Block: SiteAddress: 15318 E BROADWAY AVE Location:: CSV Zoning: UR-7 Urban Residential-7 Water District: 010 VERA Area: 11,943 Sq Ft Nbr of Bldgs: 0 Review Information: Width: 0 Nbr of Dwellings: 0 Lot: Owner: Name: YAGER, RICHARD A & JOYCE A Address: 15318 E BROADWAY AVE VERADALE, WA 99037 Hold: ❑ Depth: 0 Right Of Way (ft): 0 Review Building Plan Review Released By: Originally Released: 10/23/2007 By: tmelbourn Landuse/Zoning/HE Conditions Permits: Released By Originally Released: 10/24/2007 By: tschmidt Operator: JD Printed By: jmm Print Date: 10/25/2007 Project Number: 07004245 Inv: I Application THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Building Permit Date: 10/25/2007 Page 2 of 2 Contractor: OWNER Firm: OWNER Phone: (000) 000-0000 This Application: Total Project: Description Grp Type Notes Sq Ft Valuation Sq Ft Valuation DECK OPEN R-3 VB DECK W/ 48 $720.00 48 $720.00 RAMP Item Description RESIDENTIAL PERMIT FEE WSBC SURCHARGE SF PLNS RVW < 7999 SQ FT Notes: Totals: 48 $720.00 48 $720.00 Units Unit Desc 1 SELECT 1 SELECT 1 SELECT Permit Total Fees: Fee Amount $69.25 $4.50 $27.70 $101.45 NW corner of Progress and Sprague (parent Parcel No. 45144.2145) IS NOT ALLOWED ANY individual freestanding or monument signs for Tract A-E of BSP-03-04. See project No. 05-001343 for multi -business complex sign. (4-26-05) KK Payment Summary: Permit Type Building Permit Fee Amount $101.45 $101.45 Invoice Amount $101.45 $101.45 Amount Paid $0.00 Amount Owing $101.45 $0.00 $101.45 Disclaimer: Submittal of this application certifies the owner (or person(s) authorized by the owner) has both examined and finds the information contained within to be true and correct, and agrees that all provisions of laws and/or regulations governing this type of work will be complied with. Subsequent issuance of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the code or of any other state or local laws or ordinances. Signature: Operator: JD Printed By: jmm Print Date: 10/25/2007 crrr o> r Spokane ,� . Va11ey E Community Development Residential Construction Permit Application Permit Center 11703 E Sprague Ave, Suite B-3 Spokane Valley, WA 99206 (509)688-0036 FAX: (509)688-0037 www.spokanevalley.org PERMIT NUMBER: 7.__C-1 PERMIT FEE: New Construction n Addition/Remodel n Other: Accessory Bldg Deck fiiL ?)/ SITE ADDRESS: �'j�`QC) \��0 (a��� �lJ� . \?OKkik‘e. V A "4OY( ASSESSORS PARCEL NO: LEGAL DESCRIPTION: Building Owner: , Name: Address: l5_ `moo E. RDt�+ t..).\ City: C` 0(Pc(\k- V L -k State r4, Zip: GI q 0 . I Phone: so ry ^ t^i 43 9 _1 Fax: Contact Person Name: Phone: L\ram. Describe the scope of work in detail: Contractor: Name: Address: City: State: Zip: Phone: Fax: Contractor Lic No: Exp Date: City Business Lic. No: rim Cost of Project: $_``"- C\ L c _ 'Z Rc1. -y UV= c�1Z \ O Proposed Use: \i.N.r-,\N� c � Rt��C� '-o '`-sk,"3 **************The following MUST be complete: (write N/A if not applicable)********************** HEIGHT TO PEAK: / 7 (.. DIMENSIONS: �,,�-�'"iz # OF STORIES: 4/4 TOTAL HABITABLE SPACE: /� MAIN FLOOR TO SQ. FTG: 2" FLOOR'SQ. FTG: ittA UNFIN BASEMENT SQ. FTG: A r/� I IMPERVIOUS SURFACE AREA: �V' f fit; SQ! FTG BASEMENT'� GARAGE�S,Q,+. FTG: 4r/DECK/WY. PATIO SQ. FTG: 30% SLOPESON # OF BEDROOMS /Vii CONSTRUCTIONJJ�I//TYPE: IWA% HEAT SOURCE: SEWER O ll�1 PTIC? The permitee verifies, acknowledges and agrees by their signature that: 1) If this permit is for construction of or on a dwelling, the dwelling is/will be served by potable water. 2) Ownership of this City of Spokane Valley Permit inure to the property owner. 3) The signatory is the property owner or has permission to represent the property owner in this transaction. 4) All construction is to be done in full compliance with the City of Spokane Valley Development Code. Referenced codes are available for review at the City of Spokane Valley Permit Center. 5) This City of Spokane Valley Permit is not a permit or approval for any violation of federal, state or local laws, codes or ordinances. 6) Plans or additional information may be required to be submitted, and subsequently approved before this application can be processed. SIGNATURE: DATE: CD/a- C7 / OFSPO �g 8Y Method of Pay en : OCT 2 2 VA<<EY lir Cash 0 Check ❑ Mastercard ❑ VISA �E 10�,7 Bankcard #: Expires: VIN#: ai RMI- Authorized Signature: REVISED 2/15/07 NrER Spokane Valley® 11703 E Sprague Ave Suite B-3 ♦ Spokane Valley WA 99206 509.688.0036 ♦ Fax: 509.688.0037 1 cityhall@spokanevalley.org Residential Plan Submittal Minimums ❑ Completed Building & Mechanical application with: Accurate address, Parcel Number and/or Legal Description, description of work, owner and contractor information, signature, and date. ❑ Two sets of plans including Site Plan, elevations, floor plans, foundation plans With details, roof plan, framing plans & details. ❑ Show the height of any proposed buildings or accessory structures. ❑ Floor plan for each floor: Dimension to scale (minimum 1/8") and label each Room (including sq. footage of house and garage on plans) Show each level of existing house and square footage of any additions. ❑ All braced wall panel types: show locations and details of installation, including engineered design. ❑ Egress windows: Provide at least one window or exterior door approved for Emergency escape or rescue from a basement and in every room for sleeping. ❑ Smoke detector locations ❑ 22" X 30" attic access location ❑ 18" X 24" crawl space access: ❑ One -hour separation detail: between house and garage ❑ Floor framing details: Joist type, size, spacing and installation details ❑ Roof framing plan and details ❑ Furnace and hot water heater location. ❑ All header locations: type, size, and connections ❑ Foundation plan ❑ Insulation information Spokane ��Ualley For City Use Only PLUS Project Number 010 47.L�C Project Address ,l`7.I c4 r x' _ ,-\ 11703 E Sprague Ave Suite B-3 • Spokane Valley WA 99206 509.688.0036 • Fax: 509.688.0037 ♦ permitcenter®spokanevalley.org As part of our on -going commitment to customer service during the review process of your project application, we are providing you with a TARGET DATE for the initial technical application review. If for any reason we cannot meet this date, we will contact you with a revised target date. Your application review TARGET DATE is I c'� 70-7 The TARGET DATE is the date we estimate your project application will have had its initial technical review. It is not the date for approval or permit issuance. 1 Tips for a Smoother Project Application Review > Submit complete, accurate plans and documents. Extra time may be required for re -submittals as project application reviewers work on multiple applications and it may be several days before they can look at your new or revised information. ➢ Designate a specific contact person to communicate with the City. While the person designated as the applicant's contact person with the City can be changed, one individual with the expertise for dealing with reviewer comments would be the best choice for the entire review process. ➢ Call staff regarding the status of your project only after the target date shown at the top of the page. Although you should be contacted on or by the target date, please feel free to contact us if you haven't heard from us by your target date. Staff may contact you before the target date if the initial review is complete. By following this procedure, you will save time and allow the reviewers to complete the work more expeditiously. Steps in the Permit Process 1. Counter Complete. Your application has been accepted as counter complete. This means all of the required documents, as indicated on your Pre -Application Checklist have been submitted or have been approved for deferred submittal. This does not prevent technical staff from requesting additional information as a result of their technical review. 2. Quality Check. The next step in the process is a quality check to make sure that the application is reviewable and free from substantive flaws that would prevent technical staff from completing the technical review once it is started. When this step is complete, your application will be routed to the appropriate staff and remain in their review queue until it comes up for review. 3. Technical Compliance. Once an application is administratively complete, it is routed to technical staff for compliance review. Depending on the type of project, technical staff may include multiple reviewers. You should be contacted by phone, fax, email, or mail by your TARGET DATE once the initial technical compliance review is complete. 4. Permit Issuance. When the technical compliance review of the application is complete, including any subsequent re - submittals, each reviewer will approve their section of the application and route it to the Permit Center. When all sections of the application are received, a Permit Specialist will process the application and contact the person specified on your application for permit pick-up. Information regarding fees and pre -construction meetings (if required) will be provided by the Permit Specialist at that time. WHITE -APPLICANT PINK - BUILDING FILE REV 9/07 Spokane Valiey Project Transmittal City of Spokane Valley Community Development Department 11703 E. Sprague Ave, Suite B3 Spokane Valley, WA 99206 Phone: 509.688.0036 New project Previous pre-app meeting 121 Plan revisions Transmittal Date: Monday, October 22, 2007 Site Address: 15318 E BROADWAY AVE Parcel Number: 45144.0105 Zoning: UR-7 Water District: VERA Fire District: FD 01 Project Number: 07004245 Applicant: YAGER, RICHARD A & JOYCE A 15318 E BROADWAY AVE VERADALE, WA 99037 (509) 000-0000 e-mail: e-mail: Contact: YAGER, RICHARD A & JOYCE A Occupant: 15318 E BROADWAY AVE e-mail: VERADALE, WA 99037 (509) 000-0000 e-mail: Contractor: OWNER ( ) - 0 Arch / Engineer: e-mail: Owner: YAGER, RICHARD A & JOYCE A 15318 E BROADWAY AVE VERADALE, WA 99037 D Project DECK W/HANDICAP RAMP Description: Building Landuse Engineer Utilities Health Fire Dist Assessor APPLICATIO 1 SITE PLA PLAN S 2- Please send all plan review and project comments via e-mail to the highlighted individuals. PLANNING DEPT. BY DATE: toPLO-2 PROVED iLI 2 1- RE-CeVED CITY OP SPOKAN6 VA ..1z),, ocrNr 2007 PERmi BY: Y/ OC- BUILDING PLANNING recess area on both sides of the profile. The finger recess shall begin within a distance of 3/4 inch (19 mm) measured vertically from the tallest portion of the profile and achieve a depth of at Ieast 5/I6 inch (8 mm) within'/8 inch (22 mm) below the widest por- tion of the profile. This required depth shall con- tinue for at least 3/8 inch (10 mm) to a level that is not less than 13/4 inches (45 mm) below the tallest por- tion of the profile. The minimum width of the hand- rail above the recess shall be 11/4 inches (32 mm) to a maximum of 23/4 inches (70 mm). Edges shall have a minimum radius of 0.01 inch (0.25 mm). R311.5.7 Illumination. All stairs shall be provided with illumination in accordance with Section R303.6. R311.5.8 Special stairways. Spiral stairways and bulkhead enclosure stairways shall comply with all requirements of Section R311.5 except as specified below. R311.5.8.1 Spiral stairways. Spiral stairways are per- mitted, provided the minimum width shall be 26 inches (660 mm) with each tread having a 7% inches (190 mm) minimum tread depth at 12 inches from the narrower edge. All treads shall be identical, and the rise shall be no more than 9V, inches (241 mm). A minimum headroom of 6 feet 6 inches (1982 mm) shall be provided. R311.5.8.2 Bulkhead enclosure stairways. Stairways serving bulkhead enclosures, not part of the required building egress, providing access from the outside grade level to the basement shall be exempt from the require- ments of Sections R311.4.3 and R311.5 where the maxi- mum height from the basement finished floor level to grade adjacent to the stairway does not exceed 8 feet (2438 mm), and the grade level opening to the stairway is covered by a bulkhead enclosure with hinged doors or other approved means. R311.6 Ramps. R311.6.1 Maximum slope. Ramps shall have a maximum slope of one unit vertical in twelve units horizontal (8.3-per- cent slope). Exception: Where it is technically infeasible to comply because of site constraints, ramps may have a maximum slope of one unit vertical in eight horizontal (12.5 percent slope). R311.6.2 Landings required. A minimum 3-foot-by-3-foot (914 mm by 914 min) landing shall be provided: 1. At the top and bottom of ramps. 2. Where doors open onto ramps. 3. Where ramps change direction. R311.6.3 Handrails required. Handrails shall be provided on at least one side of all ramps exceeding a slope of one unit vertical in 12 units horizontal (8.33-percent slope). R311.6.3.1 Height. Handrail height, measured above the finished surface of the ramp slope, shall be not less than 34 inches (864 mm) and not more than 38 inches (965 mm). R311.6.3.2 Handrail grip size. Handrails on ramps shall comply with Section R311.5.6.3. R311.6.3.3 Continuity. Handrails where required on ramps shall be continuous for the full length of the ramp. Handrail ends shall be returned or shall terminate in newel posts or safety terminals. Handrails adjacent to a wall shall have a space of not less than 1.5 inches (38 mm) between the wall and the handrails. SECTION R312 GUARDS R312.1 Guards. Porches, balconies, ramps or raised floor sur- faces located more than 30 inches (762 mm) above the floor or grade below shall have guards not less than 36 inches (914 mm) in height. Open sides of stairs with a total rise of more than 30 inches (762 mm) above the floor or grade below shall have guards not less than 34 inches (864 mm) in height measured vertically from the nosing of the treads. Porches and decks which are enclosed with insect screening shall be equipped with guards where the walking surface is located more than 30 inches (762 mm) above the floor or grade below. R312.2 Guard opening limitations. Required guards on open sides of stairways, raised floor areas, balconies and porches shall have intermediate rails or ornamental closures which do not allow passage of a sphere 4 inches (102mm) or more in diameter. Exceptions: 1. The triangular openings formed by the riser, tread and bottom rail of a guard at the open side of a stairway are permitted to be of such a size that a sphere 6 inches (152 mm) cannot pass through. 2. Openings for required guards on the sides of stair treads shall not allow a sphere 4 3/8.inches (107 mm) to pass through. SECTION R313 SMOKE ALARMS R313.1 Smoke detection and notification. All smoke alarms shall be listed in accordance with UL 217 and installed in accordance with the provisions of this code and the household fire warning equipment provisions of NFPA 72. Household fire alarm systems installed in accordance with NFPA 72 that include smoke alarms, or a combination of smoke detector and audible notification device installed as required by this section for smoke alarms, shall be permitted. The household fire alarm system shall provide the same level of smoke detection and alarm as required by this section for smoke alarms in the event the fire alarm panel is removed or the system is not connected to a central station. R313.2 Location. Smoke alarms shall be installed in the fol- lowing locations: 1. In each sleeping room. 2006 INTERNATIONAL RESIDENTIAL CODE® 55 2x6-8 • Nails/Clavos: (6) 10d or/o 16d, and/y(4) 10d x 1-1/2". • Face mount hanger connects 2 x 6-8 joist to header. El colgador de montaje lateral conecta una viga doble T de 2 x 6-8 al soporte. JL26 Ref #: LU26 ►a `11.e4a Purl 7,4 DECKS: Ledger board requires '/Z" lag bolt (cry 16" o.c. with flashing behind. Guardrail 36 in. high required if floor more than 30 in. above grade. Picket spacing no more than 4 in. apart. Posts require approved base and beam connectors. Min. 24 in. frost protection to fmish grade with min. 12 in. footing base. CRY of SPit/El BY KqNF VALLEY CT - %j0? 4�f�: CE CITY COPY THIS BUILDING SUBJECT TO FIELD INSPECTION CORRECTIONS REVIEWED FOP ODleY E COMPLIANCE SPOKANE VALLEY BUILDING DIVISION