add to 2006 app poleN 0 0 TREATED POST 16d GALV. NAILS 2' X 6' GIRT (FLAT) ti TYPICAL GIRT CONNECTION NOTES FOR FLOOR PLAN D INTERIOR FRAME WOOD POSTS, SEE POST SCHEDULE THIS SHEET GABLE WALL POSTS - 6' X 6' TYPICAL DOOR POSTS - 4' X 6' TYPICAL FOOTING DIMENSIONS, B + 1' 8"; D = 3' 0" MAXIMUM POST SPACING 12' 0' PURLINS @ 24° O.C., BEARING OR JOIST HANGERS (TYPICAL) 1- p Z W -J W 0 W 0 A- 0 0 SEE ti SPANS 12' TO 50' PURLIN CONNECTION METHODS: A). PURLINS MAY BE HUNG OFF THE TRUSS TOP CHORD EACH GIRT FACES W/ STD. SIMPSON JOIST HANGERS OR EQUAL. B), PURLINS MAY BE BUTTED AND NAILED W/C2) 1601 NAILS INTO EACH PURLIN, C). PURLINS MAY BE LAPPED AND NAILED W/(3) 16d NAILS. ON CONNECTION METHODS "B" AND "C', TOENAIL BACK SIDE OF PURLIN W/(1) 16d NAIL INTO EACH TOP CHDRD MEMBER SPAN S12 BOLTS S13 16d NAI il 24' 1 4 30' 2 8 36' 2 8; 40' 3 12 50' 3 12 60' 4 16 DOUBLE TRUSSES W l7 DOUBLE TRUSSES 3 SINGLE TRUSS EI PLAN VIEW N.T.S. 12 W(//// NOTES FOR SECTION A -A Si TY ICAL PURLIN, SEE FLOOR PL N FOR SIZE qgp TR SS DESIGN BY OTHERS 013 2' 6' @ 24' ❑.C., 10' BAYS 2' 6' @ 24' ❑.C., 12' BAYS DF L #2 GIRTS FLAT @ 24' O.C. f, CO CRETE FOOTING, SEE SCHEDULE EX END POST TO TOP OF PURLIN R❑ F FASTENED TO PURLINS WITH 1 1 2' LONG VOODFAST TEKS. WALLS FASTENED TO GIRTS WITH 1' LONG W❑ODFAST TEKS. 0 tU 0 tU B %SEE IDETAIL SEE FOOTING DETAIL LDING SECTION A -A N.T.S. 12 SINGLE OVERHEAD DOOR DPTIDN FRONT ELEVATION NOTES S1 H 0 2' S3 2J 2 0 2' N.T.S. FOR FRONT ELEVATION LF TRUSS DESIGN BY OTHERS PPORT PURLINS @ END TRUSS W/2' X 6' 2' X 8' STD JOIST HANGERS, WER TRUSS FOR END OVERHANG, IF RER'D X 10" HEADER X 6' GIRTS @ 24' ❑.C., 10' BAYS, DF-L #2 X 6' GIRTS @ 24' ❑.C., 12' BAYS, DF-L #2 X 8' FACIA BOARDS S5 TREATED WOOD POSTS, SIZED PER SCHEDULE T EATED 2' X 6' BOTTOM GIRT OR TREATED 2' X 10' BOTTOM GIRT NOTE: FOR 24' SPANS & 30 PSF LIVE LOAD, 3/4" BOLTS MAY BE REPLACED WITH 22 - 16d NAILS DETAIL 1 - TRUSS COLUMN CONNECTION, PURLIN SUPPORT N.T.S. NOTE: WHEN KNEE BRACE NOT REQUIRED, USE ONLY BOLT IN TRUSS 12 MfrN CENNf NOTES FOR CONNECTION DETAIL Si MANUFACTURED TRUSS TOP CHORDS TRUSS DESIGN BY TRUSS MANUFACTURER S2 PURLIN SUPPORT STRUT 2' X 6' X FULL DEPTH OF TOP CHORD PLUS PURLIN. 4D •q" CTjoN NAIL PURLINS W/(3) 16d NAILS 0 NAIL STRUT TO TOP CHORD W/(3) 16d NAILS EACH SIDE. S4 MANUFACTURED TRUSS - NAIL TO EACH SIDE OF POST WITH 4 - 16d NAILS ON TOP NAILING BLOCK WOOD POST, SEE POST/FOOTING SCHEDULE. 4 - ' 10d NAILS SOLID BLOCKING AT CONNECTION POINTS. TYP, PURLIN, SEE FLOOR PLAN FOR SIZE 2' X 6' OR 2' X 8' EAVE GIRT KNEE BRACE, IF REQ'D. SEE POST SCHEDULE AND DETAIL 2 2' X 6' X 24' OR 2' X 8' X 24' BLOCK 3/41'0 MACHINE BOLTS W/ 2' 0 FLAT WASHER SEE CHART FOR `'QUANTITY 16d NAILS - SEE CHART FOR QUANTITY DOUBLE OVERHEAD DOOR DPTIDN OPTIONAL FRONT ELEVATION N.T.S. 1" & BOLTS INDICATED IN TABLE IN BOLTING BLOCK NOTES FOR FOOTING DETAIL TREATED POSTS AS SIZED PER SCHEDULE .VIBRATE .OR ROD CONCRETE TO OBTAIN FULL BEARING CO UNDISTURBED S❑IL _ j • FOOTING DETAIL GABLE END TRUSS 2' X 6' X 18' BOLTING BLOCK 2' N ' BOLTING BLOCK N.T.S. 8-1601NAILS CORNER POST - 16d NAILS DETAIL 3 TYP, GABLE END TRUSS CONNECTION USE BOLTING BLOCKS BELOW ALL CORNER COLUMN GIRTS NI .... 6" 8" OR 16d NAILS 10" POST GIRTS (TYP,) METAL SIDING NAILING PATTERN FOR POST LAMINATIONS NOTE: 2' X 6' LAMINATE MUST BE A TREATED MEMBER AND MUST EXTEND TO THE BOTTOM OF THE FOOTING. LAMINATE MAY BE SPLICED ABOVE MID HEIGHT OF COLUMN 4I SINGLE SLIDING DOOR OPTION OPTIONAL RT ELEVATION . 12 N.T.S. •e;s � $� OPENING 3068 MAND❑DR OPTION Y r, OPTIONAL FRONT ELEVATION N.T.S. 10 02 SPLIT SLIDER DOOR DPTIDN �I PTIONAL FRONT ELEVATION N.T.S. NOTES FOR OPTIONAL FRONT ELEVATIONS HALF TRUSS DESIGN BY OTHERS 2" X 10" HEADER UP TO 12' 0' DOORS 2' X 12' HEADER UP TO 20' ' 0' ° DOORS 2" X 12" BACKED WITH 2" X 6" UP TO 24' 0" 2' X 6' HEADER 4' X 6' DOOR POST - 8' THRU 14' WALL HEIGHT W/ 2' X 6' FACER. 6' X 6' DOOR POST - 16' & 18' WALL HEIGHT W/ 2' X 8' FACER. DOUBLE 2' X 6' KINGPOST S5 3' DETA L 2 NOTES FOR DETAIL 2- KNEEBRACE S1 TRUSS TOP CHORD, DESIGN BY OTHERS S2 TRUSS BOTTOM CHORD, DESIGN BY OTHERS S3 2' X 6' ON EACH SIDE 4 WOOD POST, SEE PDST/FOOTING SCHEDULE S5 16d GALV. NAILS, EACH SIDE NOTES) 1). KNEE BRACE REQUIRED WHERE SHOWN ON POST/FOOTING SCHEDULE. BRACE NOT REQUIRED AT GABLE END TRUSSES. 2). ALTERNATE KNEE BRACE/POST AND TRUSS/POST CONNECT.I❑N = (2) 3/4' DIA. THRU BOLTS, EACH LOCATION. KNEE BRACE N.T.S. OVERHEAD DOOR OPENING SLIDING DOOR OPENING •�� �� ��� %�� %�� •�� . �\ i�;. TYPICAL SIDE ELEVATION NOTES FOR SIDE ELEVATION 0 2' X 8' HEADER 0 2" X 10" HEADER FOR 10' & 12' SLIDING DOORS 2' X 8' HEADER FOR 8' & SMALLER SLIDING DOORS N.T.S. SHEATHING REQUIRMENTS THE FOLLOWING MINIMUM ROOF DIAPHRAGM REQUIREMENTS ARE NEEDED' ROOF STEEL' 29 GAUGE GRAND -RIB III, 36' WIDTH OR EQUIVALENT NI FIELD SCREWS' #10 x 1 1/?' AT 9' O.C. (NEXT TO HIGH RIB) • EAVE AND RIDGE PURLIN -SCREWS' #14 xl 1/2' AT BOTH SIDES OF EACH MAJOR RIB THE FOLLOWING MINIMUM END\/ALL DIAPHRAGM REQUIRMENTS ARE NEEDED' ENDWALL STEEL' 29 GAUGE GRAND -RIB III, 36' WIDTH OR EQUIVALENT * FIELD SCREWS' #10 x 1 1/E' @ 9' O.C. (NEXT TO HIGH RIB) * BASE GIRT, END TRUSS, AN]) DOOR HEADER SCREWS' *14 x 1 1/2' @ BOTH SIDES OF EACH MAJOR RIB. DIAPHRAGM SCREWS DIAPHRAGM SCREWS @ ENDWALL BASE GIRT ACROSS EAVE &LRIDGE PURLIISSON ROOF END TRUSS TOP CHORD, DIAPHRAGM I ED ABOSCREWS; ''YPICAL SCREW PATTERN, EXCEPT AS STEEL SHEETING SCREW PATTERNS BULDING SPECIFICATIONS: GENERAL - ALL BUILDING CONSTRUCTION SHALL CONFORM TO THE 2003 EDITION OF THE INTERNATIONAL BUILDING CODE (IBC 2003), AND ALL STATE & LOCAL BUILDING CODES. THESE SPECIFICATIONS AND PLANS ARE INTENDED FOR USE IN 30 OR 40 PSF LIVE LOAD, 85 MPH WIND SPEED, EXPOSURE B AND SEISMIC DESIGN CATEGORY C. DESIGN LOADS - ROOF LL = 30 OR 40 PSF ROOF DEAD LOAD = 5 PSF* CEILING LL = 0 PSF CEILING DL = 1 PSF * ROOF DL ALLOWS FOR A MAXIMUM OF 3" THICKNESS OF FIBERGLASS INSULATION. * MAXIMUM SOIL BEARING PRESSURE = 2,000 PSF MAXIMUM SOIL BEARING PRESSURE IS BASED ON SANDY GRAVEL AND/OR GRAVEL SOILS OF BETTER. LESSER SOIL CONDITIONS WILL REQUIRE REVIEW AND FOOTING SIZE ADJUSTMENT BY THE ENGINEER. CONCRETE - MINIMUM 28 DAY COMPRESSIVE STRENGTH F'c = 2,000 psi, 4 SACK MIX FOR FOOTINGS. CAST IN PLACE CONCRETE CONSTRUCTION SHALL CONFORM TO ACI 318-92. WOOD , � a,n re- MAXIMUM IS A. 1'i�lOC - STRUCTURAL LUMBER_SHALL CONFORM TO DE-L #2 OR OETTCR: BY �tJ4°I?r. :::P..",CL�v 42ULr:.�. MOISTURE CONTENT SHALL. BE r 9% BY WEIGHT. NAILING SHALL CONFORM TO IBC TABLE 2304.9.1 FASTENING SCHEDULE & OTHER APPROPRIATE SECTIONS OF CHAPTER 23''`OF IBC 2000. ALL NAILS INTO TREATED WOOD SHALL BE HOT -DIPPED ZINC COATED GALVANIZED STEEL, SILICONE BRONZE COPPER OR STAINLESS STEEL. CCA TREATED WOOD SHALL CONFORM TO THE REQUIREMENTS OF AWPA STANDARDS C-16, C-22, C-23, C-24 & C-28. POSTS FOR BUILDINGS SHALL BE AS NOTED ON THE PLANS. ALL POST MATERIALS SHALL BE HEM -FIR #2 OR BETTER, FULL DIMENSION AND GRADED BY WWPA GRADING RULES. HARDWARE SHALL BE SIMPSON OR APPROVED EQUAL. ALL BOLTS SHALL CONFORM TO ASTM A307. METAL PANELS MAY BE DELTA RIB STYLE, GALVANIZED OR PAINTED, 29 GAUGE THICKNESS, ASTM A653 STRUCTURAL QUALITY (SQ), Fy = 80.0 ksi. ROOF PANELS SHALL BE FASTENED TO PURLINS WITH PLATED, GASKETED 1 1/2" LONG METAL TO WOOD FASTENERS. WALL PANELS SHALL BE FASTENED TO GIRTS WITH PLATED, GASKETED 1" OR LONGER METAL TO WOOD FASTENERS. PANELS SHALL BE INSTALLED AND FASTENED ACCORDING TO THE MANUFACTURER'S RECOMMENDATIONS. SOIL COMPACTION - ALL BACKFILLED SOIL BENEATH FOOTINGS SHALL BE COMPACTED WITH A VIBRATORY COMPACTOR TO 95% OF THE PROCTOR DENSITY AS DETERMINED BY ASTM A1557, METHOD D. TRUSSES SHALL BE DESIGNED BY AND BEAR THE SEAL OF AN ENGINEER REGISTERED TO PRACTICE IN THE STATE IN WHICH THE BUILDING WILL BE CONSTRUCTED. TRUSS LOADING: TOP CHORD LIVE LOAD = 30 OR 40'. PSF TOP CHORD DEAD LOAD = 5 PSF (§0 BOTTOM CHORD DEAD LOAD = 1 PSF 0 TYPICAL III 1 TRUSS BOTTOM CHORD BRACING NOTES FOR TRUSS BOTTOM CHORD BRACING S1 GABLE END TRUSS S2 DOUBLE INTERIOR TRUSSES S3 2' X 4' RAT RUN BRACING @ 10' 0' O.C. S4 GABLE END POST TO TOP OF TRUSS 5) NAIL BRACES TO 2" X 3' NAILER WITH 2 - l0d NAILS S6 2' X 3' NAILER NAILED TO TRUSES W/ 3 - 10d NAILS N.T.S. TRUSS WEB BRACING INTERIOR OR GABLE END TRUSSES NOTES FOR TRUSS WEB BRACING: THE METHOD OF TRUSS WEB BRACING SHOWN ABOVE REPLACES 1' X 4' OR 2' X 4' WEB MEMBER FOLLOW THESE INSTRUCTIONS FOR ALL WEB MEMBER BRACING TO REPLACE 'RAT -RUN' WEB l0d NAILS @ 6' O.C. X 6' OR 2" X 8" L-BRACE / / -TRUSS WEB MEMBER '' -TRUSS WEB MEMBER �0d NAILS @ 6' 0.C. I-2" X 4' L-BRACE SECTION B-B SECTION B-B AT INTERIOR TRUSSES AT GABLE END TRUSS BRACING EEEQ N.T.S EXPIRES. .12/29107 POST/FOOTING SCHEDULE 12' - 24' SPANS, 30 & 40 PSF LIVE LOAD POST COLUMN FOOTING KNEE BRACE CONCRETE SPACING "H' W X D "B" DIA. "T' REQUIRED VOLUME, YD3 10'-0 8'-0" •10'-0" 6" X 6" 18" 3 O" NO 0.20 10'-0 6" X 6" 18" 3 -0" NO 0.20 - 10'-0" .-10'=0„ 12'-0" 14'-0" 6" X 6" __ 6" X 6" W/2_" X 6" 18" 3 0" 3'-0':- NO 0.20 0.20 18" NO 10'-0" 16'-0" 6" X 8" 20" 3'-0" NO 0.24 10'-0" 18'-0" 6" X 10" 20" 3'-O" NO 0.24 10'-0" 20'-0" 6" X 10" 21" 3'-0" NO 0.27 12-0" 8'-0" 6" X 6" 26" 3'-0" NO 0.41 -12-0" 10' 4" 6"6 X " 26" 3'-0" NO 0.41 12-0" 12'-0" 6" X 6" W/2" X 6" 26" 3'-O" NO 0.41 12-0" 14-0" 6" X 6" W/2" X 6" 26" 3'-0" NO 0.41 12-0" 16'-0" 6" X 8" W/2" X 6" 26" 3'-0" NO 0.41 12-0" 18'-0" 6" X 8" W/2" X 6" 26" 3'-0" NO 0.41 12'-0" 20'40" 6" X 10" W/2" X 6" 2s" 3'-2" NO 0.44 POST/FOOTING SCHEDULE 30' SPANS, 30 & 40 PSF LIVE LOAD POST COLUMN FOOTING KNEE BRACE CONCRETE SPACING "H' W X D "B" DIA. "T' REQUIRED VOLUME, YD3 10'-O" 8'-0" 6" X 6" 26" 3'-0" NO 0.41 10'-O" -10'-0" 10'-0" 6" X 6" _ 26" 3'-O" NO__ 0.41 12' -0" 6"X6"W/2"X6"_ 26 -Ye e- -O" NO - 0.41 10'-O" 14-0" 6" X 6" W/2" X 6" 26" -0 3'" NO 0.41 10'-0" 16'-0" 6" X 8" 26" 3'-0" NO 0.41 10'-O" 18'-0" 6" X 8" W/2" X 6" 26" 3'-0" NO 0.41 10'-0" _-0"_ 10' 20'-0" 22'-0" 6" X 8" WZ' X 6" 26" 3'-O" NO 0.41 0.44 6" X 10" W/2" X 6" 26" 3'-2" NO 10'-0" 24-0" 6" X 12" 26" 3'-3" NO 0.45 12-0" 8'-0" 6" X 6" 28" 3'-0" NO 0.47 12-0" 10'-0" 6" X 6" 2 28" 3'-0" NO 0.47 12-0" 12'-0" 6" X 6" W/2" X 6" 28" 3'-0" NO 0.47 12-0" ---- -- ----- 14'-028" " 6" X 8" 3'-0" " NO 0.47 6" X 8" W/2" X 6" 28" 3'-0" NO 12-0" 16'-0" 0.47 12-0" 18'-0" 6" X 10" 28" 3'4" NO 0.47 12-0" 20'-0" 6" X 12" 28" 3'-0" NO 0.47 12-0" 22'-0" 6" _X 12" W/2" X 6" 28" 3'-2" NO 0.5 --12.0"- -2O"4'- 0.56 6"X 12" 28" 3'-6" NO POST/FOOTING SCHEDULE 36' SPANS, 30 & 40 PSF LIVE LOAD POST COLUMN FOOTING KNEE BRACE CONCRETE SPACING "H' W X D "B' DIA. "T' REQUIRED VOLUME, YD3 10'-0" 8'-0" 6" X 6" 28" 3'-0" NO 0.47 10'-O" 10'-0" 6" X 6" 28" 3'-0" NO 0.47 10'-0" 12'-0" 6" X 6" W/2" X 6" 28" 3'-0" NO 0.47 10'-0 14-0" 6" X 6" W/2" X 6" 28' 3'-O" NO 0.47 10'-O" 16 -0' 6" X 8" 28" 3'-0"; NO 0.47 10'-0" 18'-0" 6" X 8"WIZ" X 6" 28" 3'-0" NO 0.47 10'-0" 20'-O" 6" X 10" 28" 3'-0" NO 0.47 10'-0 22'-0" s X 10 W/2 X 6" 28" 3'-O"NO 0.47 10'-0" 24-0" 6" X 10" W/2" X 6" 28" 3'-2" YES 0.50 12-0" 8'-0 6" X 6" 32" 3'-0" NO 0.62 12-0" 10'-0"6' X 6" 32 3'-O" NO 0.62 12-0" 12'-0" 6" X 6" W/2" X 6" 32" 3'-0" NO 0.62 12-0" 14'-0" 6" X 8" 32 3'-0" NO 0.62 12-0" 16 -0 6" X 8" W/2" X 6" -kid"- 32" 3 0" NO 0.62 12-0" 18'-0" el 10" 32" 3'-0" NO 0.62 12-0" 20'-0" 6" X 10" W/2" X 6" 32" 3'-0" NO 0.62 12-0" • 22 -0 6" X 12" 32" 3 2 NO 0.66 12-0" -24-0" 6" X 12" W/2" X 6" 32" 3'-3" NO 0.68 POST/FOOTING SCHEDULE 40' SPANS, 30 & 40 PSF LIVE LOAD POST COLUMN FOOTING KNEE BRACE CONCRETE SPACING "H' W X D "B" DIA. "T' REQUIRED VOLUME, YD3 10'-0" 8'-0" 6" X 6" 30" 3'-0" NO 0.56 10'-0" 10'-0" 6" X 6" 30" 3'-0" NO 0.66 10-0" 12 -0' 6" X 6" W/2" X 6" 30" 3'-0" NO 0.66 10'-O" 14-0" 6" X 6" W/2" X 6" 30" 3'-0" NO 0.66 10'-O" 16'-0" 6" X 8" 30" 3'-0" YES 0.55 10'-O" 16 -0 6" X 8" W/2" X 6" 30" 3'-0" NO 0.55 10'-0" 18'-0" 6" X 8" W/2" X 6" 30" 3'-0" NO 0.55 10'-O" 20'-0" 6" X 10" 30" 3'4" NO 0.55 10'-0" 22'-0" 6" X 10" W/2" X 6" 30" 3'-O" NO 0.66 10'-0" 24-0" 6" X 12" 30" 3'-2" YES 0.68 12-0" 8'-0" 6" X 6" 33" 3'-0" NO 0.66 12.0" 10'-0" 6" X 6" 33" 3'-0" NO 0.66 12-0" 12'-0" 6" X 6" W/2" X 6" 33" 3'-O" NO 0.66 12.0" 14-0" 6" X 8" 33" 3'-6 NO . .0.66. rl-U ` .1E -0 6' :n b W/z X 6" 3s' : 3 =^v' NO 0:66 12-0" -18'-0" 6" X 10" 33" ' 3'-0" NO • 0.66 1Z-0" 20'-0" 6" X 10" W/2" X 6" 33" 3'-O" NO , 0.66 124" 22'-0" 6" X 12" 33" 3'-2" NO 0.70 12-0" 24'-0" 6" X 12" W/2" X 6" 33" 3'-2" NO 0.72 POST/FOOTING SCHEDULE 48' TO 62' SPANS, 30 & 40 PSF LIVE LOAD POST COLUMN FOOTING KNEE BRACE CONCRETE SPACING "H' W X D "B" DIA. "T' REQUIRED VOLUME, YD3 10'-O" 8'-0" 6" X 6" 34' 3'-O" NO 0.70 10'-0" 10'-0" 6" X 6" 34" 3'-0" NO 0.70 10'-0" 12'-0" 6" X 6" W/2" X 6" 34' 3'-O" NO 0.70 10'-0" 14-0" 6" X 6" W/2" X 6" 34' 3'-0" NO 0.70 10'-O" 16 -0' 6" X 8" 34" 3'-O" YES 0.70 10'-O" 16 -O" 6" X 8" W/2" X 6" 34" 3'-O" NO 0.70 10'-0" 18'-0" 6" X 8" W/2" X 6" 34' 3'-0" NO_ 0.70 10'-0" 20'-0" 6" X 10" 34' 3'-O" _ YES 0.70 10'-0 22 -0 6" X 10" W/2" X 6" 34' 3'-0" NO 0.70 10'-0 24 -0 6" X 12" W/2" X 6" 34' 3'-O" YES 0.70 12-0" '-0" 6" X _6" -_ 36" -- - 3'-0" NO 0.79 12.0"- 10 -0 6 X 6" W/2" X_ 6" 36" 3'-O" NO 0.79 12-0 12'-0" 6" X 6" W/2" X 6" 36"-- -3'-0" NO 0.79 12-0"_ 14-0" 6" X 8" 36" 3'-0" NO 0.79 12-0" 1s'-0" 6" X 8" W/2" X 6" 36" 3'-0" NO 0.79 12-0" 18'-0" 6" X 10" 36" 3'-0" YES 0.79 12-0" 20 -O" 6" X 10" W/2" X 6" 36" 3'-0" NO_ 0.79 12-0" 22 -0 6"X 12" W/2" X 6" 36" 3'-2" __ __ NO- 0.83 12-0" 24'-0" 6" X.12" W/2" X s" 36" 3'-2" NO 0.83 POST/FOOTING SCHEDULE 64 TO 60' SPANS, 30 & 40 PSF LIVE LOAD POST COLUMN FOOTING KNEE BRACE CONCRETE SPACING "M' W X D "B' DIA. "T' REQUIRED VOLUME, YD3 10'-0" 8'-0" 6" X 6" 36" 3'-0" NO 0.79 10'-O" 10'-0" 6" X 6" 36" 3'-0" NO 0.79 10'-O" 12'-036" " 6" X 6" W/2" X 6" 3'-0 " NO 0.79 10'-O" _ 14'-0" 6" X 8" 36" 3'-0" NO 0.79 10'-0" 16'-0" 6" X 8" W/2" X 6" 36" 3'-0" NO 0.79 10'-0" 18'-0" 6" X 10" 36' 3'-0" NO 0.79 10'-O" 20'-0" 6" X 10" W/2" X 6" 36" 3'-0" YES 0.79 10'-0" 22'-0" 6" X 10" W/2" X 6" 36" 3'-0" NO 0.79 10'-0" 24-0" 6" X 12" 36" 3'-2" YES 0.83 12-0" 8'-0' 6" X 6" 40" 3'-0" NO 0.97 12-0" 10'-0" 6" X 6" W/2" X 6" 40" 3'-0" NO 0.97 12-0" 12'-0" 6" X 8" 40" 3'-0" NO 0.97 12-0" 14-0" 6" _X 8" W/2" X_ 6" 40" 3'-0" NO 0.97 12-0" 16'-0" 6" X 8" W/2" X 6" -40" - 3'-0"- NO 0.97 12-0" 18'-0" 6" X 10" 40" 3'-0" YES 0.97 12-0" 20'-0" 6" X 10" W/2" X 6" 40" 3'-0" NO 0.97 12-0" 22'-0" 6" X 12" W/2" X 6" 40" 3'-O" NO 0.97 12-0" 24?-0" 6" X 12" W/2" X 6" 40" 3'-2" NO 1.03 NOTE: 1. THE NEXT LARGER SIZE POST MAY BE SUBSTITUTED FOR POSTS WITH 2" X 6" LAMINATIONS. 2. ENDWALL POSTS SHALL BE 6" X 6" ROUGH CUT HEM -FIR #2 TREATED POSTS UP TO 16'-0"' WALL HEIGHT. ABOVE 16' WALL HEIGHT, ENDWALL POSTS SHALL BE 6" X 8" ROUGH CUT HEM -FIR #2 POSTS. 3. FOOTINGS FOR ENDWALL POSTS SHALL BE :A MINIMUM OF 20"0 X 3'-0" DEEP FOR WALL HEIGHTS TO 16'-0".`ABOVE 16' WALL HEIGHT, FOOTINGS SHALL BE 24"0 X 3'-4" DEEP. ,ABOVE FOOTING DESIGNS ARE FOR POST FRAME BUILDINGS WITH CONCRETE FLOORS (CONTRAINED POSTS). IF BUILDINGS WILL NOT CONCRETE FLOORS, INCREASE FOOTING DIAMETER X 2" & FOOTING DEPTH X 4". WAMBEKE ENGINEERING 2913 E. 61st Court Daniel Wanbeke, P. E. Spokane, WA 99223 Telephone' 509-443-6186 Fax' 509-448-6582 .e-nail . dwanbeke@risn.cor LAYOUT, STRUCTURAL DETAILS AND SPECIFICATIONS 12' TO 60' POST FRAME BUILDINGS 30 & 40 PSF LIVE LOAD - IBC 2003 J. M. COOK CONSTRUCTION 26809 E. ' SANSON NEWMAN LAKE, WASHINGTON 99025 BY DRAWN WAMBEKE ,REV BY DATE DESCRIPTION OF CHANGE CHECKED DATE 8-16-06 DRAWING NO.' JMCOOK.IBC2003 PROJECT NO. 2006 SCALE' N.T.S. SHEET, 1 OF 1 REV. PROVIDE DIAGRAMS AND ENGINEERING LAYOUTS FOR ROOF TRUSSES, BEAMS AND FLOOR SYSTEMS PRIOR TO FRAMING INSPECTIONS CITY COPY THIS BUILDING SUBJECT TO FIELD INSPECTION CORRECTIONS SParan REVIEWED Ai LIANCE SPQLEY BUI DING FOR COD M I SON • Itiy7�!E VALLEY L 'N`' 9 �,6