Loading...
WSEC Table, Bracing Panel, Wall BracingWSEC TABLE 6-2 PRESCRIPTIVE REQUIREMENTS°4 FOR GROUP R OCCUPANCY CLIMATE ZONE 2 Option Glazing Area10: of floor Glazing U-Factor Door9 U- Factor Ceiling2 Vaulted Ceiling Wa1112 Above Grade Wall? into Below Grade Wall? ext4 Below Grade Floors Slabs on Grade Vertical Overhead" I. 10% 0.40 0.58 0.20 R-38 R-30 R-21 int' R-21 R-12 R-30 R-10 II. 15% 0.40 0.58 0.20 R-38 R-30 R-19+ R-58 R-21 R-12 R-30 R-10 III. 17% 0.37 0.58 0.20 R-38 R-30 R-19+ R-58 R-21 R-12 R-30 R-10 IV. 25% Group R-1 Occupancy Only 0.35 0.58 0.20 R-38 / U=0.031 R-30 / U=0.034 R-21 int' / U=0.054 R-15 R-12 R-30 / U=0.029 R-10 / F=0.54 V. Unlimited Group R-3 Occupancy Only 0.35 0.58 0.20 R-38 R-30 R-21 int' R-21 R-12 R-30 R-10 VI. Unlimited Group R-1 Occupancy Only 0.32 0.58 0.20 R-38 / U=0.031 R-30 / U=0.034 R-21 int' / U=0.054 R-15 R-12 R-30 / U=0.029 R-10 / F=0.54 * Reference Case 0. Nominal R-values are for wood frame assemblies only or assemblies built in accordance with Section 601.1. 1. Minimum requirements for each option listed. For example, if a proposed design has a glazing ratio to the conditioned floor area of 13%, it shall comply with all of the requirements of the 15% glazing option (or higher). Proposed designs which cannot meet the specific requirements of a listed option above may calculate compliance by Chapters 4 or 5 of this Code. 2. Requirement applies to all ceilings except single rafter or joist vaulted ceilings. 3. Requirement applicable only to single rafter or joist vaulted ceilings. 4. Below grade walls shall be insulated either on the exterior to a minimum level of R-10, or on the interior to the same level as walls above grade. Exterior insulation installed on below grade walls shall be a water resistant material, manufactured for its intended use, and installed according to the manufacturer's specifications. See Section 602.2. 5. Floors over crawl spaces or exposed to ambient air conditions. 6. Required slab perimeter insulation shall be a water resistant material, manufactured for its intended use, and installed according to manufacturer's specifications. See Section 602.4. 7. Int. denotes standard framing 16 inches on center with headers insulated with a minimum of R-5 insulation. WSEC Builder's Field Guide 5th Edition COOPERATIVE EXTENSION WASHINGTON STATE UNIVERSITY ENERGY PROGRAM 1-7 FIGURE 1 CONSTRUCTION DETAILS FOR THE APA NARROW WALL BRACING METHOD WITHOUT HOLD-DOWNS OVER CONCRETE OR MASONRY BLOCK FOUNDATION Outside Elevation Max. height 10' oa Min. width based on 6:1 height -to -width ratio: For 11 1 exam le:16 min. for 8 height p o g Extent of header (Two braced wall segments) Extent of header (One braced wall segment) Fasten sheathing to header with 8d common nails in 3" grid pattern as shown and 3" o.c. in all framing (studs and sills) typ. Top plate continuity is required per R602.3.2 1000 Ib header -to -jack -stud strap on both sides of opening (Install on backside as shown on Side Elevation, Ref. No. LSTA24) i':'`I:>t;;;>!'r<»t;;i>.; " " " ;:�Q,p. Min. 2 x2 x3/16 late washer : � P If panel splice is needed it shall occur within 24" of mid -height. Blocking is not required. No. of jack studs per table R502_5(1&2) Anchor bolt per R403.1.6 Typ. ti Foundation per code Side Elevation ,,,,Sheathing filler if needed 16d sinker nails in 2 rows @ 3" o.c. 1000 Ib header - to -jack -stud strap on both sides of opening (Ref. No. LSTA24) 3/8" min. thickness wood structural panel sheathing Not to scale MAX. HEIGHT 10'- 0" SIMPSON UPLIFT STRAP 1,800 POUNDS . A , • •., k .• d••••7"•43.• ° 0, .4 d• A • • 0 'A. • 41”.S1[11,1i IN1,111 "112M111 Aill!liA11111111: C1311111111111114W111111 •44.1.• • e .• .4'd• 0 . . 0.• . . 0.• •04. . 4 . A. A 'or A 'A. A ••• '••• 0 'A. 0 'A 'A 06 A.6 Al: A• .: A.; .4 • TWO ANCHOR BOLTS INSTALLED IN ACCORDANCE WITH FIGURE R403.1(1) SHALL BE PROVIDED IN EACH PANEL. ANCHOR BLOTS SHALL BE PLACED AT PANEL QUARTER POINTS 7_,-..7-54.111111111 . If 111 lil'5111[111i111:Ta11111,1111 'IT •Ad.a . .1. .4 0.• 4.4. 81,•d•• . •• • • • • P • • '0' • '0' 0 2' 8" MI NI. WIDTH 7/16" OSB SHEATHING 3/S" MIN. NAILED WITH Sd COMMON OR GALVINIZED BOX NAILS IN ACCORDANCE WITH TABLE P602.3(1) AND BLOCKED AT ALL WOOD STRUCTURAL PANEL SHEATHING EDGES. BACK EACH STRAP WT A STUD RECOMMENDED HOLD IN 8" FROM EDGE OF BRACING PANEL impututroacutml!!!!!!!!logil 11 I ' 1"111111111111Nr11. '. 4 A . . . .*4. IN FIRST STORY OF TWO-STORY BUILDINGS, SHALL HAVE AT LEAST THREE ANCHOR BOLTS, PLACED AT ONE -FIFTH POINTS SIMPSON UPLIFT STRAP 3,000 POUNDS REeykR TOP 4150 TOM oF Founl okri o w L t- SCALE: I" = l'- 0" AT _,TERNATE BRACING PANEL RAta.10.6 ALTERNATE BRAC I) WALL PANELS FOUNDATIONS R404.1.1 Masonry foundation walls. Concrete masonry and clay masonry. foundation walls shall be constructed as set forth in Tables R404.1.1(1), R404.1.1(2), R404.1.1(3) and R404.1.1(4) and shall also comply with the provisions of this section and the applicable provisions of Sections R606, R607 and R608. In Seismic Design Categories D, and D2, concrete masonry and clay masonry foundation walls shall comply with Section R404.1.4. Rubble stone masonry foundation walls shall be constructed in accor- dance with Sections R404.1.8 and R606.2.2. Rubble stone masonry walls shall not be used in Seismic Design Catego- ries D, and D2. R404.1.2 Concrete foundation walls. Concrete foundation walls shall be constructed as set forth in Tables R404.1.1(1), R404.1.1(2), R404.1.1(3) and R404.1.1(4), and shall also comply with the provisions of this section and the applicable provisions of Section R402.2. In Seismic Design Categories D, and D2, concrete foundation walls shall comply with Sec- tion R404.1.4. R404.1.3 Design required. A design in accordance with ac- cepted engineering practice shall be provided for concrete or masonry foundation walls when any of the following con- ditions exist: TABLE R404.1.1(1) PLAIN CONCRETE AND PLAIN MASONRY 1. Walls are subject to hydrostatic pressure from ground- water. 2. Walls supporting more than 48 inches (1219 mm) of unbalanced backfill that do not have permanent lateral support at the top and bottom. MAXIMUM WALL HEIGHT (feet) MAXIMUM UNBALANCED BACKFILL HEIGHT` (feet) PLAIN CONCRETE MINIMUM NOMINAL WALL THICKNESS (inches) PLAIN MASONRY° MINIMUM NOMINAL WALL THICKNESS (inches) Soil classes° GW, GP, SW and SP GM, GC, SM, SM-SC and ML SC, MH, ML-CL and inorganic CL GW, GP, SW and SP GM, GC, SM, SM-SC and ML SC, MH, ML-CL and inorganic CL 5 4 5 6 6 6 6 6 6 6 solidd or 8 6 solidd or 8 6 solidd or 8 8 6 solidd or 8 10 6 4 5 6 6 6 6 6 6 8g 6 6 8g 6 solidd or 8 6soliddor8 8 6 solidd or 8 8 10 6 solidd or 8 10 12 7 4 5 6 7 6 6 6 8 6 6 8 8 6 8g 8 10 6 solidd or 8 6 solidd or 8 10 12 8 10 12 10 solidd 8 10 10 solidd 12 solidd 8 4 5 6 7 8 6 6 8g 8 10 6 6 8 10 10 6 8 10 10 12 6 solidd or 8 6 solidd or 8 10 12 10 solidd 6 solidd or 8 10 12 12 solidd 12 solidd 8 12 12 solidd Footnote e Footnote e 9 4 5 6 7 8 9 6 6 8 8 10 J 0 6 8g 8 10 10 12 6 8 10 10 12 Footnote f 6 solidd or 8 8 10 12 12 solidd Footnote e 6 solidd or 8 10 12 12 solidd Footnote e Footnote e 8 12 12 solidd Footnote e Footnote e Footnote e For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square inch = 6.895 Pa. a. Mortar shall be Type M or S and masonry shall be laid in running bond. Ungrouted hollow masonry units are permitted except where otherwise indicated. b. Soil classes are in accordance with the Unified Soil Classification System. Refer to Table R405.1. c. Unbalanced backfill height is the difference in height of the exterior and interior finish ground levels. Where an interior concrete slab is provided, the unbalanced backfill height shall be measured from the exterior finish ground level to the top of the interior concrete slab. d. Solid grouted hollow units or solid masonry units. e. Wall construction shall be in accordance with Table R404.1.1(2) or a design shall be provided. f. A design is required. g. Thickness may be 6 inches, provided minimum specified compressive strength of concrete, f'c, is 4,000 psi. 72 2003 INTERNATIONAL RESIDENTIAL CODE® FOUNDATICNS TABLE R404.1.1(2) REINFORCED CONCRETE AND MASONRY° FOUNDATION WALLS MAXIMUM WALL HEIGHT (feet) MAXIMUM UNBALANCED BACKFILL HEIGHT' (feet) MINIMUM VERTICAL REINFORCEMENT SIZE AND SPACING"' FOR 8-INCH NOMINAL WALL THICKNESS Soil classes' GW, GP, SW and SP soils GM, GC, SM, SM-SC and ML soils SC, MH, ML-CL and inorganic CL soils 6 5 6 #4 at 48" o.c. #4 at 48" o.c. #4 at 48" o.c. #4 at 40" o.c. #4 at 48" o.c. #5 at 48" o.c. 7 4 5 6 7 #4 at 48" o.c. #4 at 48" o.c. #4 at 48" o.c. #4 at 40" o.c. #4 at 48" o.c. #4 at 48" o.c. #5 at 48" o.c. #5 at 40" o.c. #4 at 48" o.c. #4 at 40" o.c. #5 at 40" o.c. #6 at 48" o.c. 8 5 6 7 8 #4 at 48" o.c. #4 at 48" o.c. #5 at 48" o.c. #5 at 40" o.c. #4 at 48" o.c. #5 at 48" o.c. #6 at 48" o.c. #6 at 40" o.c. #4 at 40" o.c. #5 at 40" o.c. #6 at 40" o.c. #6 at 24" o.c. 9 5 6 7 8 9 #4 at 48" o.c. #4 at 48" o.c. #5 at 48" o.c. #5 at 40" o.c. #6 at 40" o.c. #4 at 48" o.c. #5 at 48" o.c. #6 at 48" o.c. #6 at 32" o.c. #6 at 24" o.c. #5 at 48" o.c. #6 at 48" o.c. #6 at 32" o.c. #6 at 24" o.c. #6 at 16" o.c. For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm. a. Mortar shall be Type M or S and masonry shall be laid in running bond. b. Alternative reinforcing bar sizes and spacings having an equivalent cross -sectional area of reinforcement per lineal foot of wall shall be permitted provided the spacing of the reinforcement does not exceed 72 inches. c. Vertical reinforcement shall be Grade 60 minimum. The distance from the face of the soil side of the wall to the center of vertical reinforcement shall be at least 5 inches. d. Soil classes are in accordance with the Unified Soil Classification System. Refer to Table R405.1. e. Unbalanced backfill height is the difference in height of the exterior and interior finish ground levels. Where an interior concrete slab is provided, the unbalanced backfill height shall be measured from the exterior finish ground level to the top of the interior concrete slab. TABLE R404.1.1(3) REINFORCED CONCRETE AND MASONRYa FOUNDATION WALLS MAXIMUM WALL HEIGHT (feet) MAXIMUM UNBALANCED BACKFILL HEIGHT' (feet) VERTICAL REINFORCEMENT SIZE AND SPACINGb•` FOR 12-INCH NOMINAL WALL THICKNESS Soil classes d GW, GP, SW and SP soils GM, GC, SM, SM-SC and ML soils SC, MH, ML-CL and inorganic CL soils 7 4 5 6 7 #4 at 72" o.c. #4 at 72" o.c. #4 at 72" o.c. #4 at 72" o.c. #4 at 72" o.c. . #4 at 72" o.c. #4 at 64" o.c. #4 at 48" o.c. #4 at 72" o.c. #4 at 72" o.c. #4 at 48" o.c. #5 at 56" o.c. 8 5 6 7 8 #4 at 72" o.c. #4 at 72" o.c. #4 at 64" o.c, #4 at 48" o.c. #4 at 72" o.c. #4 at 56" o.c. #5 at 64" o.c. #4 at 32" o.c. #4 at 72" o.c. #5 at 72" o.c. #4 at 32" o.c. #5 at 40" o.c. 9 5 6 7 8 9 #4 at 72" o.c. #4 at 72" o.c. #4 at 56" o.c. #4 at 64" o.c. #5 at 56" o.c. #4 at 72" o.c. #4 at 56" o.c. #4 at 40" o.c. #6 at 64" o.c. #7 at 72" o.c. #4 at 72" o.c. #5 at 64" o.c. #6 at 64" o.c. #6 at 48" o.c. #6 at 40" o.c. For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm. a. Mortar shall be Type M or S and masonry shall be laid in running bond. b. Alternative reinforcing bar sizes and spacing having an equivalent cross -sectional area of reinforcement per lineal foot of wall shall be permitted provided the spacing of the reinforcement does not exceed 72 inches. c. Vertical reinforcement shall be Grade 60 minimum. The distance from the face of the soil side of the wall to the center of vertical reinforcement shall be at least 8.75 inches. d. Soil classes are in accordance with the Unified Soil Classification System. Refer to Table R405.1. e. Unbalanced backfill height is the difference in height of the exterior and interior finish ground levels. Where an interior concrete slab is provided, the unbalanced backfill height shall be measured from the exterior finish ground level to the top of the interior concrete slab. 2003 INTERNATIONAL RESIDENTIAL CODE® 73 2) #5 rebar o extend 24 .aches beyond opening. Reinforcement for openings in plain concrete ar to extend ning. Doorway: uire rebar in 1909.6.3 Openings in walls. Not less than two No. 5 bars shall be provided around window and door openings. Such bars shall extend at least 24 inches (610 mm) beyond the corners of openings. * All openings for windows and doors in structural plain concrete walls must be bound by two No. 5 (16) bars as follows. For openings not extending to the bottom of the wall, the bars must be placed on all four sides of the opening. For openings extending to the bottom of the wall, the bars are only necessary along the sides and top. To provide continuity at the corners of the openings, the bars must extend 24 inches (610 mm) past the corners. These extensions should occur at all four corners of an opening not extending to the bottom of the wall, and at the two top corners for other openings. opening. WALL CONSTRUCTION NO. 4 CONTINUOUS BAR AS REQUIRED IN SECTION R611.7.1 TOP OF WALL STORY L<2'(0.61m) m 5 2 Z_ 2 E N 0 MIDDLE OF SPAN, A. NOT REQUIRING STIRRUPS SEE TABLE R611.7(2), R611.7(3), R611.7(4), R611.7(5), OR R611.7(6) LINTEL REINFORCEMENT AS REQUIRED 24" L>_2'(0.61m) 6 m 24" 0.6 m' WALL REINFORCEMENT AS REQUIRED OPEN REINFORCEMENT AS REQUIRED PER TABLE R611.7(1) FIGURE R611.7(2) REINFORCEMENT OF OPENINGS 1.5 IN. MIN. 2.5 IN. MAX. - SEE TABLE R611.7(2), R611.7(3), R611.7(6). R611.7(9)OR R611.7(10).—*. For SI: 1 inch = 25.4 mm. NOTE: Section cut through flat wall. 1.51N. MIN. - 2.5 IN. MAX. jai N•I MEI MEI ••I 1111111 EMI ..I IUI 1111•I i•1 �NI NI URI Intl ME I. NMI /I MN NMI ME1 I\' MN NMI \•I NO 4 BAR LINTEL REINFORCEMENT REQUIRED MINIMUM NO. 3 STIRRUP AS REQUIRED SULATING FORM HORIZONTAL LINTEL REINFORCEMENT AS REQUIRED FIGURE R611.7(3) ICF LINTELS FOR FLAT AND SCREEN -GRID WALLS 186 2003 INTERNATIONAL RESIDENTIAL CODE' WALL CONSTRUCTION R611.7.1.3 Horizontal steel. Concrete walls with a minimum thickness of 4 inches (102 mm) shall have a minimum of one continuous No. 4 horizontal reinforc- ing bar placed at 32 inches (812 mm) on center with one bar within 12 inches (305 min) of the top of the wall story. Concrete walls 5.5 inches (140 mm) thick or greater shall have a minimum of' one continuous No.4 horizontal reinforcing bar placed at 48 inches (1219 mm) on center with one bar located with in 12 inches (305 mm) of the top of the wall story. For townhouses in Seismic Design Category C, the minimum horizontal reinforcement shall be one No. 5 at 24 inches (610 m) on center or one No. 4 at 16 inches (407 mm) on center. For all buildings in Seismic Design Categories D, and D2, the minimum horizontal rein- forcement shall be one No. 5 at 18 inches (457 mm) on center or one No. 4 at 12 inches (305 mm) on center. Horizontal reinforcement shall be continuous around building corners using comer bars or by bending the bars. In either case, the minimum lap splice shall be 24 inches (610 mm). For townhouses in Seismic Design Category C and for all buildings in Seismic Design Cat- egories D2 and D2, each end of all horizontal reinforce- ment shall terminate with a standard hook or lap splice. R611.7.1.4 Lap Splices. Where lap splicing of vertical or horizontal reinforcing steel is necessary, the lap splice shall be in accordance with Figure R611.7.1.4 and a minimum of 40db, where db is the diameter of the smaller bar. The maximum distance between noncontact parallel bars at a lap splice shall not exceed 8db. R611.7.1.5 Standard hook. Where the free end of a re- inforcing bar is required to have a standard hook, the hook shall be a 180-degree bend plus 4db extension but not less than 21/2 inches, or a 90-degree bend plus 12db extension. R611.7.2 Wall openings. Wall openings shall have a mini- mum of 8 inches (203 mm) of depth of concrete for flat and waffle -grid ICF walls and 12 inches (305 mm) for screen -grid walls over the length of the opening. When the depth of concrete above the opening is less than 12 inches for flat or waffle -grid walls, lintels in accordance with Sec- tion R611.7.3 shall be provided. Reinforcement around openings shall be provided in accordance with Table R611.7(1) and Figure R611.7(2). All reinforcement placed horizontally above or below an opening shall extend a mini- mum of 24 inches (610 mm) beyond the limits of the open- ing. Wall opening reinforcement shall be provided in addition to the reinforcement required by Sections R611.3, R611.4, R611.5 and R611.7.1. The perimeter of all wall openings shall be framed with a minimum 2-inch by 4-inch plate, anchored to the wall with 1/2 inch (12.7 mm) diameter anchor bolts spaced a maximum of 24 inches (610 mm) on center. The bolts shall be embedded into the concrete a mini- mum of 4 inches (102 mm) and have a minimum of 11/2 (38 mm) inches of concrete cover to the face of the wall. Exception: The 2-inch by 4-inch plate is not required where the wall is formed to provide solid concrete around the perimeter of the opening with a minimum depth of 4 inches (102 mm) for the full thickness of the wall. R611.7.3 Lintels. R611.7.3.1 General requirements. Lintels shall be provided over all openings greater than or equal to 2 feet (610 mm) in width. Lintels for flat ICF walls shall be constructed in accordance with Figure R611.7(3) and Table R611.7(2) or R611.7(3). Lintels for waffle -grid ICF walls shall be constructed in accordance with Fig- ure R611.7(4) or Figure R611.7(5) and Table R611.7(4) or R611.7(5). Lintels for screen -grid ICF walls shall be constructed in accordance with Figure R611.7(6) or Figure R611.7(7). Lintel construction in accordance with Figure R611.7(3) shall be permitted to be used with waffle -grid and screen -grid ICF wall construction. Lintel depths are permitted to be increased by the height of the ICF wall located directly above the opening, pro- vided that the lintel depth spans the entire length of the opening. TABLE R611.7(1 MINIMUM WALL OPENING REINFORCEMENT REQUIREMENTS IN ICF WALLS WALL TYPE AND OPENING WIDTH (L) (feet) MINIMUM HORIZONTAL OPENING REINFORCEMENT MINIMUM VERTICAL OPENING REINFORCEMENT Flat, Waffle-, and Screen -Grid: L <2 (0.61) None required None required Flat, Waffle-, and Screen -Grid: L >_ 2 (0.61) Provide lintels in accordance with Section R611.7.3, Provide one No. 4 bar within 12 inches (305 nun) from the bottom of the opening. Top and bottom lintel reinforcement shall extend a minimum of 24 inches (610 mm) beyond the limits of the opening. In locations with wind speeds less than or equal to 110 mph (177 kmhr) or in Seismic Design Categories A and B, provide one No. 4 bar for the full height of the wall story within 12 inches (305 ram) of each side of the opening. In locations with wind speeds greater than 110 mph (177 km/hr), townhouses in Seismic Design Category C, or all buildings in Seismic Design Categories D, and D2, provide two No. 4 bars or one No. 5 bar for the full height of the wall story within 12 inches (305 mm) of each side of the opening. For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 mile per hour = 1.609 km/h. NOTE: This table is based on concrete with a minimum specified compressive strength of 2,500 psi, reinforcing steel with a minimum yield strength of 40,000 psi and an assumed equiva- lent rectangular cross section. This table is not intended to prohibit the use of ICF manufacturer's tables based on engineering analysis in accordance with ACI 318. 172 2003 INTERNATIONAL RESIDENTIAL CODE® WALL CONSTRUCTION TABLE R611.7(2) MAXIMUM ALLOWABLE CLEAR SPANS FOR ICF LINTELS FOR FLAT LOAD -BEARING WALLSa,b,c,d,f MAXIMUM CLEAR SPAN, (feet -inches) (Number is Middle of Span, A)e Supporting Roof Only Supporting Light Framed 2nd Story and Roof Supporting ICF Second Story and Roof MINIMUM LINTEL Ground Snow Load THICKNESS, T (inches) LINTEL DEPTH, D (inches) 30 psf 70 psf 30 psf 70 psf 30 psf 70 psf 8 4-9 (1-2) 4-2 (0-9) 3-10 (0-8) 3-4 (0-6) 3-5 (0-6) 3-1 (0-5) 12 6-8 (1-11) 5-5 (1-3) 5-0 (1-1) 4 5 (0-10) 4-6 (0-10) 4-0 (0-8) 3.5 16 7-11 (2-9) -' 6-5 (1-9) 6-0 (1-6) S-3 (1-2) 5-4 (1-2). „ 4-10 (1-0) 20 8-11 (3-5) 7-4 (2-3) 6-9 (1-11) 6-0 : (1-6) 6-1 (1-7) 5-6 (1-3) 24 9-10 (4-1) 8-1 (2-9) 7-6 (2-4) 6-7 (1-10) 6-9 (1 11) 6-1 (1-6) 8 5-2 (1-10) 4-2 (1-2) 3-10 {1-0) 3-5 (0-9) 3-5 (0-10) 3-1 (0-8) 17 6-8 (3-0) 5-5 (2-0) 5-0 (1-9) 4-5 (1-4) 4-6 (1-4) 4-1 (1-1) 5.5 16 7-10 (4-1) 6-5 (2-9) 6-0 (2-5) 5-3 (1-10) 5-4 (1-11) 4-10 (1-7) 20 8-10 (5-3) 7-3 (3-6) 6-9 (3-1) 6-0 (2-4) 6-1 (2-5) 5-6 (2-0) 24 9-8 (6-3) 8-0 (4-3) , 7-5 (3-8) 6-7 (2-11) 6-8 (3-0) 6-0 (2-5) 8 5-2 (2-6) - 4-2 (1-8) 3-11 (1-5) 3.5 ; (1-1) 3-6 (1-1) 3.2 (0-11) 12 6-7 (4-0) 5-5 (2-8) 5-0 (2-4) 4-5 (1-10) 4-6 (1-10) 4-1 (1-6) 7.5 16 7 9 (5-5)', 6-5 (3 8) 5-11 (3-3) 5-3 (2-6) 5-4 (2-7) 4-10 (2-2) 20 8-8 (6-10) 7 2 (4-8) ' 6-8 (4-2) 5-11. (3-3) 6-0 (3-4) 5-5 (2-9) 24 9-6 (8-2) 7-11 (5-8) 7-4 (5 1)- 6-6 (3-11) 6-7 (4-1) 6-0 (3-4) 8 5-2 (3-1) 4-7 (2-1) 3-11 (1-9) 3-5 (1-5) 3-6 (1-5) 3-2 (1-2) 9.5 12 6-7 (5-0) 5-5 (3-4) 5-0 (3.0) 4-5 (2-4) 4-6 (2-5) 4-1 (1-11) ]6 7-8 (6-9) 6-4 (4-7) 5-11 (4-2). 5-3 (3-3) 5-4 (3-4) 4-10 (2-8) For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square inch = 6.895 kN/m2, 1 pound per square foot = 0.U479 kiv/m`. a. This table is based on concrete with a minimum specified compressive strength of 2,500 psi, reinforcing steel with a minimum yield strength of 40,000 psi and an assumed equivalent rectangular cross section. When reinforcement with a minimum yield strength of 60,000 psi is used, the span lengths in the shaded cells shall be increased by 1.2 times the table values. b. This table is not intended to prohibit the use of ICF manufacturer's tables based on engineering analysis in accordance with ACI 318. c. Deflection criteria: U240. d. Design load assumptions: Floor dead load is 10 psf Attic live load is 20 psf Floor live load is 30 psf Roof dead load is 15 psf Building width is 32 feet ICF wall dead load is 69 psf Light -framed wall dead load is 10 psf e. No. 3 stirrups are required at d/2 spacing except no stirrups are required for the distance, (A), shown in the middle portion of the span in accordance with Figure R611.7(2) and Section R611.7.3.2. f. Interpolation is permitted between ground snow loads and between lintel depths. 2003 INTERNATIONAL RESIDENTIAL CODE® 173 WALL CONSTRUCTION TABLE R611.7(3) MAXIMUM ALLOWABLE CLEAR SPANS FOR ICF LINTELS FOR FLAT LOAD -BEARING WALLS"'e,0 MINIMUM LINTEL THICKNESS, T (inches) LINTEL DEPTH, D (inches) MAXIMUM CLEAR SPAN, (feet -inches) (Number is Middle of Span, A)c Supporting Roof Supporting Light Framed 2nd Story and Roof Supporting ICF Second Story and Roof Ground Snow Load 30 psf 70 psf 30 psf 70 psf 30 psf 70 psf 8 4-9 4-2 3-11 3-7 3-7 3-5 (1-2) (0-9) (0-8) (0-6) (0-6) (0-5) 12 7-2 6-3 5-11 5-5 5-5 5-0 (1-11) (1-3) (1-1) (0-10) (0-10) (0-8) 3.5 16 9-6 8-0 7-4 6-6 6-7 5-11 (2-9) (1-9) (1-6) (1-2) (1-2) (1-0) 20 11-1 9-1 8-4 7-5 ;7-6 6-9 (3-5) (2-3) (1-11) 24 12-2 10-0 9-3 " 8-2 8-4 7_6 (4-1) (2-9) (2-4). (1-10) `. .. (1-11) (1-6) 8 5-6 4-10 4-7 4-2 4-2 3-10 (1-10) (1-2) (1-0) (0-9) (0-10) (0-8) 1/ 8-3 6-9 6-3 5-6 5-7 5-0 (3-0) (2-0) (1-9) (1-4) (1-4) (1-1) 5.5 16 9-9 8-0 7-5 6-6 6-7 6-0 (4-1) (2-9) (2-5) (1-10) (1-11) : (1-7) /0 10-11 9-0 S-4 . 7-5 7-6 6-9. (5-3) (3-6) (3-1) ...: (2-4) (2-5) .. : (2-0) 14 ` 12-0 9-11 9-3 8-2 8-3 7-6 (6-3) .,. (4-3) (3-8) (2-11) (3-0) (2-5) 8 6-1 5-2 4-9 4-3 4-3 3-10 (2-6) (1-8) (1-5) (1-1) (1-1) (0-11) 12 8-2 6-9 6-3 5-6 5-7 5-0 (4-0) (2-8) (2-4) (1-10) (1-10) :: (1-6) 7.5 16 9 7. 7-11 7-4 6-6 6-7 fi-0 (5-5) (3-8) (3-3). (2-6) (2-7) .. ,.. (2-2) 20 10-10 8-11 8-4 7-4 7-6 6-9 (6-10) : (4-8) (4-2) (3-3) (3-4) (2-9) 24 11-10 9-10 4-2 8.1 8-3 . ". 7-5 (8.2) (5-8) ' (5-1) (3-11) (4-1). (3-4) 8 6-4 (3-1) 5-2 (2-1) 4-10 (1-9) 4-3 (1-5) 4-4 .. (1-5) 3-1I (1-2) .. 12 8-2 6-8. 6-2 -: 5-6 5-7 5-0 (5-0) (3-4) (3-0) (2-4) (2-5) (1-11) 9.5 16 9-6 7.-11 ". 7-4 6-6 6-7 5-11 (6-9) ; (4-7) (4-2) (3-3) (3-4) (22-3) 10-8 8-10 3-3 7-4 7-520 6-9 .- (8-4) (5-10) (5-4) (4-2) (4-3) (3-6) 24 11.7 9-9 9-0 8-1 8-2 7-5 (10-0) (6-11) (6-5). ._ (5-0) (5-2) (4-3) For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square inch = 6.895 kN/m', 1 pound per square foot = 0.0479 kN/m-. a. This table is based on concrete with a minimum specified compressive strength of 2,500 psi, reinforcing steel with a minimum yield strength of 40,000 psi and an assumed equivalent rectangular cross section. When reinforcement with a minimum yield strength of 60,000 psi is used the spanlengthsin the shaded cells shall be increased by 1.2 times the table values. b. This table is not intended to prohibit the use of ICF manufacturer's tables based on engineering analysis in accordance with ACI 318. c. Deflection criterion: I/240. d. Design load assumptions: Floor dead load is 10 psf Attic live load is 20 psf Floor live load is 30 psf Roof dead load is 15 psf Building width is 32 feet ICF wall dead load is 69 psf Light -framed wall dead load is 10 psf e. No. 3 stirrups are required at d/2 spacing except no stirrups are required for the distance, (A), shown in the middle portion of the span in accordance with Figure R611.7(2) and Section R611.7.3.2. f. Interpolation is permitted between ground snow loads and between lintel depths. 174 2003 INTERNATIONAL RESIDENTIAL CODE°