Loading...
2003, 06-20 Permit App BD-03-689 ResidenceBOX 3 CONTACT PERSON OF PROJECT L.CAnc (), ADDRESS 99a9 !Uewpoi1 /iwc, CITY j BOX 4 SEWER AVAILABILITY (1�� City of SPOKANE VALLEY prECEIIVE a.JUN 2.3 2003 (0W- 003 i X iyiUo37 PRR��IEJ5A__17 �I BUILDING PERMIT APPLICATION Box 1 OWNER G L` QrKAAC LU'I1OB LOCATION ) 131,5 C, r- CAKA OWNER'S ADDRESS CITY PHONE cia6 — 3317 DESCRIBE JOB �U(tD u,:?k I �c)..Soo.v C1PY &r*j<'s THIS PROPERTY IS OWNED BY: SINGLE/MARRIED i•.? (4- PARTNERSHIP CORP. BOX 2 CONTRACTOR'S NAME c;,ti�E�t.2�7 �v�,(>> y,� �5 LLC PHONE L/6h• (0// CONTRACTOR'S ADDRESS 7/oz9 tie)(4-L k61.14 f7.t)t CITY J Okoil Q u CONTRACTOR'S REG.# ' CA. e I B j ?Wo F EXPIRATION DATE OVb 6 /i3 (CARD MUST BE PRESENTED AND COPIED ORIFILD I ) / c PHONE �6'(5-- 6o /1 ZIP%Z/, WATER AVAILABILITY t� BOX 5 ESTIMATED PROJECT COST $ /,. 5-0 (` EXISTING BLDG. VALUATION $ 7`1 qO 6 (j Fe) BOX 6 PROPERTY TAX ACCOUNT NUMBER LEGAL DESCRIPTION "44,2 . // Z� 1 1 Z_ E025- f (IF NECESSARY, PLEASE SUBMIT A SEPARATE PAGE WITH THE LEGAL DESCRIPTION) CENSUS NUMBER LOT NUMBER BOX 7 BUILDING SQUARE FOOTAGE (Existing / proposed) 1ST FLOOR aoZC 2ND FLOOR 3RD FLOOR / OTHER / BASEMENT FINISHED N.)(0 / BASEMENT UNFINISHED / DECK / GARAGE 1-4?-01 CARPORT / TOTAL / HEIGHT TO PEAK OF BUILDING I3 BOX 8 ) SINGLE FAMILY ( )MULTIFAMILY (NO. OF UNITS (�) NEW CONSTRUCTION ( ) COMMERCIAL / INDUSTRIAL ) ( ) EXISTING STRUCTURE ( )TENANT IMPROVEMENT TOTAL AREA OF PROPERTY SQ. FT. IMPERVIOUS SURFACE ! SQ. FT. BOX 9 PLUMBING FIXTURES (Including rough -ins) MECHANICAL APPLIANCES PLEASE USE THE ATTACHED PLUMBING / MECHANICAL FORM FOR THE LISTING OF ALL APPLIANCES, SYSTEMS, HEATING AND AIR UNITS, FIREPLACE INSERTS, WATER HEATERS, CONVERSION BURNERS, LAWN SPRINKLER SYSTEMS, BACK FLOW PREVENTERS, ET AL: BOX 10 Water Service meter size (if known) I lk Also see BOX 4 BOX 11 Septic Tank — Not generally allowed in the City of Spokane Valley. For special circumstances contact Your sewer purveyor and the Health District (See BOX 4) BOX 12 Street use may require a " Street Use Permit" for sewer, water, sidewalks, curb cuts. Contact the Public Works Department. VERIFY UNDER THE PENALTY OF PERJURY THAT THE INFORMATION FURNISHED BY ME IS TRUE AND CORRECT TO THE BEST OF MY KNOWLEDGE AND FURTHER THAT I AM AUTHORIZED BY THE OWNER OF THE \BOVE PREMISES TO PERFORM THE WORK FORHICH THE APPLICATION IS MADE. )W NER / AGENT DATE 6/ZCJ/37 (OVER) I hereby authorize the City of Spokane Valley to charge the fee for this permit to my credit card: Visa Mastercard — _ Expiration Date Print the name of the Bolder Signature OFFICE USE ONLY - PLEASE DO NOT WRITE BELOW THIS LINE ZONE SETBACKS: FRONT SIDE REAR HEIGHT LIMIT PLANNING DEPARTMENT APPROVAL DISAPPROVAL REMARKS DATE SEPA: EXEMPT • NOT EXEMPT FIRE DEPARTMENT:APPROVAL DISAPPROVAL DATE REMARKS PUBLIC WORKS DEPARTMENT APPROVAL DISAPPROVAL DATE TYPE OF JOB: NEW RESIDENCE RES. ADD/ALT NEW INDUSTRIAL IND. ADD/ALT NEW COMMERCIAL COMM. ALT/ADD NEW MULTIFAMILY NO. UNITS MULTIFAMILY ADD/ALT TENANT IMP. ROOF OTHER OCCUPANCY TYPE OF CONSTRUCTION TORIES oa. BUILDING SQ. FT. 377 BUILDING SQ. FT. @ = BUILDING SQ. FT. @ `7 �O BU.I DfNC Q. FT. / .5 . 0 ' @ TOTAL SQ. FT. TOTAL VALUATIO BUILDING PERMIT Npo:3 -kr7 PLAN CHECK FEE REC'D 74 %' ,, // `t7 RECEIPT NUMBER PERMIT FEE 13 077.31 PLAN CHECK FEE PLUMBING FEE `746? on MECH. FEE re2 TOTAL FE S (,% 3Z Go n -- WSBCC SURCHARGE _7 o ENERGY SURCHARGE OTHER CHARGES ; AMOUNT DUE /// 747 32. BUILDING DEPARTMNT APPROVAL ASSIGNED A DDRESS BY 2o© �r1 DATE (� esk, Sexier* CUtd`tr LiAi CERTIFICATE OF WATER AVAILABILITY Project Description GOU4,4 0� c (� 2 This section to be completed by Applicant J Project Name: Parcel Number(s): General Description of Project: Water requested: Number of Residential Taps ; or Commercial Flow gpm Fire Flow Requirements This section be City of Spokane Valley Division of Building Name of Water Purveyor Fire Flow Required gpm; at psi; for minutes Certification By Purveyor Water System Name WA DOH AD# Yes No 0 fi 1. The water system has a current Washington Department of Health Operating permit, allowing the number of new taps or water requested. 11 1 _ 2. The proposed project is consistent with the water purveyor's DOH approved water system plan. {3 0 3. The off site source, storage and transmission infrastructure of the water purveyor is sufficient to provide the service required for the proposed project. p [ 4. N/A If 3 is no, has financial security been provided to insure infrastructure improvements are completed? (Check Not Applicable if 3 is yes) C] .G 5. The water system is willing and able to provide water, in conformance to minimum levels of service, as requested at this time. If water system is unable, or unwilling to supply water at this time, please describe why: This Certificate of Water Availability is non -transferable to other projects. (For relevant laws, see RCW 58.17, 36.70A and 19.27.) Further, a new Certificate of Water Availability shall be required if: 1) a project modification results in greater water demand; or 2) a project extension of time is requested. Certified by: Print Name Title Signature Date CONCURRENCY DETERMINATION This Section to be Completed by the City of Spokane Valley If box 1, 2 and 5 are checked yes, and 3 or 4 is checked yes and all other information is complete and the water purveyor has signed the above Certificate of Water Availability, concurrency is satisfied for water. Otherwise, refer applicant to the Department of Public Works. Yes No 0 CI This development is exempt from concurrency for water service. d - This development meets the concurrency requirements for water service. City of Spokane Valley Representative Signature Date PADAL - Fact Sheet Page 1 of 2 SeoKane County — - - Spokane County Parcel Data Locator All Data As Of Monday, June 09, 2003 Summary Parties Values Taxes Sales Info Seg / Merge Events / Notices Land Imp .,. ;free . iedo .:r,:<;.;: Fact Sheet Taxes Only Fact Sheet with Ta) Fact Sheet without Taxes for Property Number 45162.1126 All Data As Of Monday, June 09, 2003 Site Address 11315 E BROADWAY AVE, SPOKANE TCA 0144 Owner GETHSEMANE LUTHERAN Address 11315 E BROADWAY AVE SPOKANE, WA 99206-7213 Acreage Land Sq Feet 193,985 Property Class 77 - Unknown From Conversion Exemption 2003 Year Parcel Status Active Taxpayer EVANG LUTH SYNOD Address 11315 E BROADWAY AVE SPOKANE, WA 99206-7213 Market Values 2003 Land 96,990 Exempt Value 406,490 Improvements 309,500 Personal Property 0 Total Value 406,490 Active Exemptions DoR Institutional Legal Description OPPORTUNITY W1/2 EXC E25FT B72 Improvements Improvement Type Description Year Built Siz Commercial Church 1956 4,73 Dwelling Dwelling 1954 1,66 Other Residential Detached Garage 1977 1,24 Other Residential Detached Garage 1977 1,24 Features Description Fireplace Size UOM 1 Created on Wednesday, June 11, 2003 at 1:18:17 PM Help New Search Modify Search Pant http://webpadal/ParcelFactSheet.asp?Type=NoTax 6/11/2003 City of SPOKANE VALLEY BUILDING DEPARTMENT 11707 E. Sprague Avenue, #106, Spokane �Valley, Washington 99206 - Tel. 509-688-0036 — Fax. 509-688-0037 SITE ADDRESS: 1 t 3 L S L.Oi9 v- PERMIT NO. DATE: 61 �1? / 03 (INSTRUCTIONS 1) Your permit will be processed more efficiently. if you provide all of the requested information. Department staff can help you with general questions about this form. Your building must match the selected option requirements without exceptions or substitutions. 2) Glazing percentage determines which option to choose. Complete the following glazing area calculation before proceeding to the option table below. GLAZING AREA CALCULATION: SF. — SF. TOTAL WINDOW AREA _ HEATED FLOOR AREA (ALL FLOORS) _ % OF GLAZING NOTE: Use rough opening (R/O) for window area. Include all half-lite and full-lite door glazing in this calculation. %1 CAN'T COMPLY? If none of the Prescriptive (Chapter 6) Options below are acceptable, consider systems analysis (Chapter 4) or, Component Performance (Chapter 5) Approach. The main advantage is flexibility to juggle individual U- factors (R-values) as long as an overall maximum value isn't exceeded. Note that the overall performance requirements are no less stringent than the Prescriptive requirements. Calculations may be performed by hand or, using an acceptable computer software program. Helpful forms and other resources can be downloaded at http://www.energy.wsu.edu/ buildings. INSPECTORS COPY MUST BE ATTACHED TO APPROVED PLANS Ela � Glazing °, , �� /0 Floor GlWall odor Door' U-factor Ceiling 2 Valuted ceiling' Wall Above Grade Wall* inP Below Grade Wall * ext° Below Grade Floor' Slab on Grade Vertical Overhead" I. 1 O% 0.40 0.58 0.20 R-38 R-30 R-21 int, R-21 R-12 R-30 R-10 • II.* 15% 0.40 0.58 0.20 R-38 R-30 R15+ R-21 R-12 R-30 R-10 ■ 111. 17% 0.37 0.58 0.20 R-38 R30 R-19 + R-21 R-12 R-30 R-10 • IV. Unlimited Om i� R-3 Only 0.35 0.58 0.20 R-38 R-30 Rn 1 R-21 R-12 R-30 R-10 • 0. Nominal R-values are fix wood frame assemblies only or asserrtlies built in accordance with Section 601.1 1. Ivinimum requirements for each option libled. For example, if a proposed design has a glazing ratio to the conditioned floor area of 13%, it shall comply with all of the requirements of the 15%glazing option (or higher). Proposed designs, which cannot meet the specific requirements of a listed option above, Fay calculate corrpliarxce by Gepters 4 or 5 of this Code. 2 Requirement applies to all ceilirgs except single rafter orjoistvaulted ceilings. 'MN/ denotes Advanced Framed Ceiling. 3. Requirement applicable only to single rafter or joist vaulted ceilings. 4. Below grade walls shall be insulated either on the exterior to a rririmum level of RIO, or on the interior to the same level as walls above grade. Exterior insulation installed on below grade walls shall be a water resistant material, manufactured for its intended use, and installed according to the manufacturer's specifications. See Section 6022. 5. . Roors over crawl spaces or exposed to ambient air conditions. 6. Required slab perimeter insulations shall be a water resistant material, manufactured for its intended use, and installed according to manufacturer's specifications. 7. Int. denotes standard faming 16 inches on center with headers insulated with a rrininum or R5 insulation. 8. This wall insulation requirement denotes R19 wall cavity insulation plus R5 foam sheathing. 9. Doors, including all fire doors, shall be assigned default (,factors from Tabor 10-6C 10. Mere a maximum glazing area is listed, the total glazing area (combined vertical plus overhead) as a percent of gross conditioned floor area shall be less than or equal to that value. Overhead glazing with (factor of U=4.40 or less is not included in glazing area limitations. 11. Overhead glazing shall have U 4actors deterrined in accordance with NFRC 100 a as specified in Section 502.1.5. 12. Log and solid tirrber walls with a minimum average thickness a 3.5' are exempt form this insulation requiremeh Form 5-050801-2001 Residential Comp Form This brochure is provided to assist in deciphering some of the Energy Code updates, and focuses primarily on RESIDENTIAL changes of significance. This notice does not contain all of the changes occurring in the 2001 WSEC. • Chapter 6, Prescriptive Requirements Approach - The code is now fuel -blind. Two tables (6-1, 6-2) replace six previous tables. Table 6-2 is applicable in Climate Zone II, Eastern Washington. • Table 6-2 offers four options to achieve compliance based on the percentage of glazing in the home. Two options (I, IV) require wall insulation values of R-21, the remaining two options (II, El) require R-19 + R-5 foam sheathing There are no substitutions permitted for the foam -sheathing requirement in Options II, III. *Hint: If your home design falls within the parameters of Options II or III, you may select option IV thus permitting unlimited glazing area with U-factors of 0.35 or better. The benefit: you may then use the R-21 batts for wall insulation. ▪ Glazing U-factors of 0.40 are the minimum efficiency requirements for windows, and some instances may require U-factors of 0.35. • Minimum door U-factors are 0.20. • Options I and IV require headers to be insulated to R-5 minimum. • Ceiling insulation R-values have not changed. • Compliance through Chapters 4 and 5 (heat loss calculations) may still be used, however, the Wattsun program is being phased out. A new spreadsheet will be available soon through the WSU Energy Extension Program and will be available on-line at: www.energy.wsu.edu/buildings/. In the mean time, if you use the Wattsun software it must be version 5.7 for acceptance. Note: It will be increasingly difficult to show compliance with un-insulated basement walls. REMINDER - VIAQ/WSEC REQUIREMENTS Compliance has been off the mark in the following areas of the Ventilation & Indoor Air Quality Code/Energy Codes since they became effective July 1, 2001. • Labels must be provided on the whole house ventilation controls (e.g.; 24 hour timer), which read: "Whole House Ventilation (see operating instructions)." Instructions must also be provided for the homeowner describing the Whole House Ventilation System's operation. • HVAC ductwork/furnace cabinets outside the conditioned space (attic, crawl space, garage) or stud bays, joist cavities/spaces used to transport air must be sealed with welds, gaskets, mastics or mastic -plus -embedded -fabric systems. UL 181A tape is permitted for rigid glass ducts, and UL 181B tape is permitted for flexible ducts. Common duct tape is not permitted unless: the HVAC equipment (air handler in the case of heat pumps) and ductwork are located entirely within the conditioned space. 0 N LY ONE FORM. Attached is the new Washington State Energy Code Compliance Form containing Table 6-2, which reflects the upcoming insulation values. This form must be used if you choose to comply by the prescriptive approach (no calculations necessary). This must be completed prior to receiving your permit. For questions and information regarding these changes please contact our office at: 477-3675, or visit Washington State University Energy Extension Program web site: www.energy.wsu.edu/buildings/ . S&' jValley Ca11 24 hours before inspection required Phone 509.688-0036 Fax 509.688-0037 DEPARTMENT OF PUBLIC WORKS Anticipated start date O(-, 20 /0-3 Permit # PW APPROACH PERMIT APPLICATION Location of property I. \ 3 15 F ; B % LiJc.t, L, (Address/Parcel #, if available) Applicant Name G ertAr . Address 113 1.5 C 2Y,a\,Ic Phone '72 (n 3 31 % Contractor's Name Pokne 1 z .€20 Sk1.5-167/5 U � Address 94'2? k M e(x f ti PhoneIv 6 & Contractor's Reg# CAI"\e 1 es99,? F Expires Zi%k/M(*)3 PROJECT DESCRIPTION (Provide site sketch) n Residential Driveway Existing Curb & Gutter Culvert Installation Commercial/Industrial Driveway Rural Road Section Sidewalk Repair/Construction Other conditions ?c rpor'x ark el, (UC ( S V See construction requirements and details on reverse. Bond/insurance certification must be on file with the City. SPECIAL CONDITIONS: PERMIT FEE $ Inspection Fee$ I hereby authorize the City of Spokane Valley to charge the fee for this permit to my credit card. Card # Expiration Date Name of Holder Signature Fees Paid$ Date !nit Excerpts from Spokane Valley Standards (3.24, and details A8 and A-8a): • Every driveway approach must provide access to an off road parking area located on private property. The driveway shall be of sufficient length so a vehicle in the driveway does not project into the road right of way, sidewalk, or pathway. • Public or private driveways in industrial, commercial, multiple family, church or any like use shall be constructed to allow vehicles to exit without backing onto a public road. • Driveway approaches shall be constructed to avoid interference with existing drainage inlets, culverts, road lighting standards, utility poles, traffic regulating devices, fire hydrants or other public utilities. The applicant shall bear the cost of relocating any such public facility. • Driveway approach grades within the right of way shall not exceed 8% in urban area, or 2% in rural areas. Driveway grades shall not exceed 10% within ten feet of a city right of way. See Standards for a more complete listing of requirements. GRADE OF RURAL PRIVATE DRIVEWAY sl METHOD OF ❑ CASH DATE: (TIY (11' Spokane ,,,,,i*VaH ey Plumbing Permit Application 11707 East Sprague Avenue, Suite 106 509-688-0036 - Phone Spokane Valley, WA 99206 509-688-0037 - Fax For Inspections, call 509-688-0054 PROJECT ADDRESS: ' 13 (5 E ) f1 J (.t`ti� u l PERMIT USE: OWNER: CSC fc)i'C�.61E' � Ci � tIN PHONE (Daytime Contact): 9 2_ 7 MAILING ADDRESS: 1(,3 IS E 3coc 0wa (street) (city/stat 510 �) � it e_ (7�) 9 i 20 „ b �� / AC o� l► zvn Sic. [MI�� ,`i�M> La:PG.r12( LICEc0NA.SE: # B5 ?' t0 r' MAILING ADDRESS: ely0/9 0. Il)e )C4 Htu PHONE #: 6(6 ‘ ^ b G ! / k we WZ ?7d%e (street) ci stat ( ty/ �+} (LL') PLUMBING FIXTURES DESCRIPTION DETAILS # OF UNITS X COST EQUALS AMOUNT 1 TOILETS WATER CLOSET, BIDETS 2_ X $6 = 2 URINALS X $6 3 TUBS 2, X $6 = 4 SHOWERS (PER TRAP) BATH, STALL, ON -SITE BUILT X $6 - 5 SINKS LAVS/BASINS, BAR, FLOOR, KITCHEN, LAUNDRY, UTILITY, JANITOR, PHOTO, X- RAY, FOOD, PREP/CULINARY/MEAT L J X $6 = 6 DISHWASHER Z X $6 - 7 CLOTHES WASHER ,. X $6 8 GARBAGE DISPOSAL X $6 = 9 WATER SOFTENER X $6 = 10 ELECT. HOT WATER TANK NOTE: IF GAS, SEE MECHANICAL X $6 = 11 FLOOR DRAINS AREA, CASE, COIL, TRENCH, CONDENSATE 'J_ X $6 = 12 FOUNTAINS, DRINKING X $6 = 13 WATER PIPING/DRAIN-IN WASTE, VENT, PLUMBING REVERSAL INSTALLATION, ALTERATION, REPAIR, REVERSALS X $6 = 14 SEWAGE EJECTOR GRINDER, SUMP PUMP X $6 - 15 WATER USING DEVICE ICE AND/OR COFFEE MAKER, HOSE BIB, S 1'hAMER, PROOFER, CARBONATOR, SWAMP COOLER X $6 = 16 CROSS CONNECTION DEVICE VACUUM BREAKER, CHECK VALVE, AND R.P.B.P.D. FOR: VATS, TANKS, BOILERS X $6 = 17 SPRINKLER SYS 1 EM X $25 = 18 INTERCEPTORS GREASE TRAP, SAND TRAP, CHEMICAL HOLDING TANK X $6 19 MEDICAL GAS per outlet NITROUS, OXYGEN X $6 = 20 MISC. PLUMBING FLYTURE X $6 = PAYMENT VISA- CI-IECK • Ennin ■ FVDT1 r ' Rues a ;a SUBTOTAL: PLUS PROCESSING FEE: �$3Fr9A `•— _ R. c. TOTAL PERMIT FEE DUE: 3ANKCARD NUMBER: 1UTHORIZED SIGNATURE: *Wane Wane ._ .Valley Mechanical Permit Application 11707 East Sprague Avenue, Suite 106 509-688-0036 - Phone Spokane Valley, WA 99206 509-688-0037 - Fax For Inspections, call 509-688-0054 PROJECT ADDRESS: l 1 31,5 E 8rrao kkruA PERMIT USE: OWNER / (, �5 �ttv* ��� i,, PHONE (Daytime Contact): 724, 3) % 7 MAILING ADDRESS:DD�S JlA` }me. (street) (city/state) (ZIP) j CONTRACTOR i z'c dl�f, l� i ,S, i 1�. L(� LICENSE #: Vet r� (O J Clt/o F— (( MAILING ADDRESS: 9'0.1 IU, Mew� pis) ram I Qor4 14 J get 2 tg" (V)p,K,CO3t, PHONE #: % �C� I 1'ZI�) _-.9. �mot �Z1 (street) (city/state) ( P ) METHOD OF PA ❑ CASH ❑ C DATE: DESCRIPTION OF WORK # OF UNITS X COST EQUALS AMOUNT 1 FUEL BURNING APPLIANCE = OR < 100,000 Z X $15 2 FUEL BURNING APPLIANCE > 100,000 X $19 = 3 UNLISTED APPLIANCE (ADDITIONAL FEE) = OR <400,000 X $50 = 4 UNLISTED APPLIANCE (ADDITIONAL FEE) > 400,000 X $100 5 USED APPLIANCE (WSEC min. AFUE rating) = or <400,000 X $50 6 USED APPLIANCE (WSEC min. AFUE rating) > 400,000 X $100 = 7 BOILER/REFRIGERATION 1-100M BTU X $15 = 8 BOILER/REFRIGERATION 101- 500M BTU X $28 = 9 BOILER/REFRIGERATION 501-1,000M BTU X $39 - 10 BOILER/REFRIGERATION 1001- 1,750M BTU X $57 11 BOILER/REFRIGERATION +1750M BTU X $95 = 12 GAS LOG, GAS INSERT, GAS FIREPLACE - X $10 - 13 RANGE - X $10 = 14 DRYER - X $10 = 15 FUEL BURNING WATER HEATER - 2 X $10 - 16 MISC. FUEL BURNING APPL. - X $10 - 17 GAS PIPING (ea. Outlet) - "F X $1 = 18 DUCT SYSTEMS - 2- X $10 = 19 VENTILATING FANS - X $10 - 20 AIR HANDLER (DOES NOT include ducting) = OR < 10,000CFM z, X $12 = 21 AIR HANDLER (DOES NOT indude ducting) > 10,000 CFM X $19 - 22 EVAPORATIVE COOLERS - X $10 = 23 TYPE I HOOD - X $50 = 24 TYPE G HOOD - X $10 = 25 HEAT PUMP/AIR CONDITIONER 0-3 TON X $12 - 26 AIR CONDITIONER 3-15 TON X $20 = 27 AIR CONDITIONER 15-30 TON X $25 = 28 AIR CONDITIONER 30-50 TON X $35 = 29 AIR CONDITIONER +50 TON X $60 = 30 LPG STORAGE TANK - X $10 = 31 WOOD OR PELLET STOVE/INSERT - X $10 = 32 WOOD STOVE - FREE STANDING - X $25 - 4IENT ��qq " w VISA 11h+�C'if�"".r SUBTOTAL: PLUS PROCESSING FEE: farctirr TOTAL PERMIT FEE DUE: '1 v� EXPIRES: BANKCARD NUMBER: AUTHORIZED SIGNATURE: i..T.; 2.0978 6 2.0982 2.0979 III : 2 211983 " 11. 2"..5 2.0933 "L.: _. 2.0987 20984 12_2 un.... . 2.0997 .i.1 2.0923 170 8 4V4741. 1_1 Ly4424.4; 2.0986 !7.:-(19111 • 2.0901 -43975 :5 2.0922 I 2.0717 z 0910 1 I 1.0R55 2 2.0215 .14 7. 4 , . 2.0911 : 2.0952 5, 1.0851 1.: 18 -• 211951 I 1,1 . 1.0(446 ..,. 24X117 t, 2.0902 14 I )1.:: )N AIL; „...L.-‘.„:1:1 :2202 , 2;0929 ; 2.0927 .5, 2.0903 r 4,;;59Qa. ) ; 81Th ,T,:j._.. a . ... ......1 .10 • ..; 1.0827 I I . 2.2203 : '1' : PP. 62, -1.--ii, - 2 0928 te-4. ...,..-1 2.1111 1 ,. 22.117.14 . ., ..-. I -: (k) A, ., 2}10 C;' '5E! , ,J , 2.1152 ' ! 1 ., 1.0841 2. 2.1112 2,1115 "- 3 ... 1..... Z 211-:. ... 21:11:11161,31.. 1 .4 4 -4 •.. 11I., '11 --: .". , .. .42.1153 ._......14:SO ....':, .113..0... -.,,, 1.01140 1.9 2.111-. I Iljuir± s- 1 i 2.1162 21126 72 :.I' 2.'...•.• 1.m12i61n:7i3e.w1er :,7:,,i..':i.:M.....I ..IS-..•.4-..: "S3':1',.24:'14.'.14.i,.S15:4.1..i .i'.-.‘:3- -'1'1,'.i-'L.- V-111I•....; i51M1-;t,t-4:'--.1.,.R.. Lc-h- .1..i.I•li...i..f,.n 'IS- IS- 1I 1•I I,.:..t1Z:ir a :t -1-c- -3 2. Lt, )• . 41iI:.1lI4 -i4j'0a18"I. 3.4 7r"-_ 2.iiso 2110 '2.1119;2.111R ,pt 1k9-* -% _c9.2qs'.I" 12.122 2.117..2.11.4 2.1121I 2.1170I 2.1157 1 -1tki i .Si -Jn t:".. 2'( . ... , i • ';'' I $ - -r. •..... b dr 1' !: Lilg1. i:iiiii tv. n . 'A17 hiA. , • -11 '74: .;f?-i , . - - •ir,;)"....... 1c W J • •M • .44 -2.0956. l" 2.0963 2.0996 12 . , 2.11962 1.11i1A Ek)4H. M Production Date: Se tember 18 2(XX) INFORMATION SYSTEMS 09 ffii NE SW \ se /; NOTICE: The information shown on this map Is compiled from various sources, and is not warranted WI W its accuracy. Users are reminded that e..ont nocomputs must be obtained from the ,Poi+ cit I Main Floor Plan For Gethsemane Lutheran Church Duplex 05/12/2003 Window Schedule NUMBER OTY FLOOR SIZE DIMENSIONS W01 1 0 4040 48'X48' W02 1 0 40310 48'X46' W03 4 0 5030 60'X38- W04 4 1 3050 36'X60' WO5 2 1 3030 36'X38' W06 4 1 4030 481X36' WO/ 2 1 2030 24-X36- W08 2 1 6050 72'X60' Door Schedule NUMBER OTY FLOOR SIZE DIMENSIONS R/O 001 2 0 3068 38X80X1 3/4' 37X81 1/2 002 4 0 2888 32X80X1 3B' 33%81 1/2 003 2 6068 72X80' 73X81 1/2 004 3 3068 38X80X1 3/4' 37X81 1/2 005 2 8070 98X84' 97%8512 006 6 2668 30X80X13/8' 31%81 12 CO7 4 2888 30X80' 31X81 12 008 / 3068 38X80X1318' 371(8112 CO9 1 2068 2080' 251(8112 0010 1 1 2268 26X80' 27%81 1/2 D11 4 1 5068 60X80' 611(8112 D12 1 1 2668 32X80X13/6' 331(81 12 1313 1 1 2468 28X80X1 3/8' 291(81 1/2 LIVING AREA 2205 sq ft Scale 1/8"= 1 Foot r Ste i ,I 11 it Ir Deck II DECK I II sxe II Ir �.3. xa.4._ m __ n �- II Lance Martin Panelized Building Systems LLC —J I .- � � tl Oo01 � KITCHEN oOO OC KITCHEN 12s5'a 10S10' I19-x104. ST LAUNDRY LaundryT ST DIMNG Inv yin. GARAGE I e.r.23-5' / — — — 1 GARAGE \ee _IILLI�— sa- — _ J Sx '11,0'1/4})'vc- SII `4t2i LIVING 1t4Pxl97 a os Foundation Plan for Gethsemane Lutheran Church No Framing in Basement except for Bearing and Stales 98" Concrete Walls or to sprat Grade 18 X 8 Concrete Footings 4" Concrete Slab 8" Concrete Walls Reber As Per County Code Radon System and Gravel as Per Code Insulation as Per Code fl't1y YO' Walk out Steps to ground Level 6C ra4,tor —I Walk out Steps to ground Level azie TV Bearing 0 Fro 9loeidg In Won Extra Thick Conc ete 2x12 Header Boom ar v.I• Proposed Future Bath UTILITY Radon Sytt.m f' FN Blot klq In Wilt I -G 1 11.; UTILITY '^ Y LIVING AREA 2200 TA e 1I Water Line ITV GARAGE ITV xTT-Y Back Fill and Compact L � 4" Sewer Line ITT GARAGE II'-8 xfl-3 -Bearing Extra Thick Concrete IT Back Fill and Compact -4 inc Ira F T O '`Proposed Future Bath as• 1' Wate Line 4 ' Sewer Line Scab 1/8"=1 Foot