Loading...
2007, 03-23 Permit App 07000931 Pole BldgProject Number: 07000931 Inv: I Application THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Project Information: Permit Use: 990 SQFT POLE BLDG Setbacks: Front Left: Right: Rear: Site Information: Plat Key: 000000 Name: Range Contact: PITTMAN, L I & R C Address: 7605 E BROADWAY AVE C - S - Z: SPOKANE, WA 99212 Phone: (509) 953-6463 Group Name: Project Name: Date: 3/23/2007 Page 1 of 2 District: Sout Parcel Number: 35232.1914 SiteAddress: 4602 E 2ND AVE Location:: CSV Zoning: UR-3.5 Block: Urban Residential3.5 Water District: 003 CARNHOPE Area: 6,750 Sq Ft Width: 0 Nbr of Bldgs: 0 Nbr of Dwellings: 0 Review Information: Lot: Owner: Name: PITTMAN, L I & R C Address: 7605 E BROADWAY AVE SPOKANE, WA 99212 Hold: ❑ Depth: 0 Right Of Way (ft): 0 Review Building Plan Review eleased By: Originally Released: 3/23/2007 By: TMELBOU Landuse/Zoning/HE Conditions OLU?et— a ,eri \ccj JD k)v: lr%�rn5 "tZ. 0'— St CZ Permits: _ �.... Operator: JD Printed By: JD Print Date: 3/23/2007 35` n 71 7\ 3 wa ioI PLANNING DEPT. APPROVED BY:m „If DATE: 3/ Z"-Ion} o' Project Number: 07000931 Inv: 1 Application THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Contractor: OWNER Description Grp Type Notes POLE BDLG U-1 VB Item Description RESIDENTIAL PERMIT FEE ACCESSORY PLANS REVIEW WSBC SURCHARGE Notes: Payment Summary: ,. Permit Type Building Permit Building Permit Firm: OWNER Phone: (000) This Application: Sq Ft Valuation 990 $18,810.00 Date: 3/23/2007 Page 2 of 2 000-0000 Total Project: Sq Ft Valuation 990 $18,810.00 Totals: 990 $18,810.00 Units Unit Desc 1 SELECT 1 SELECT 1 SELECT Fee Amount $388.56 Permit Total Fees: Invoice Amount 990 $18,810.00 Fee Amount $307.25 $76.81 $4.50 Amount Paid $388.56 $0.00 $388.56 $388.56 $0.00 $388.56 Amount Owina $388.56 $388.56 Disclaimer: Submittal of this application certifies the owner (or person(s) authorized by the owner) has both examined and finds the information contained within to be true and correct, and agrees that all provisions of laws and/or regulations governing this type of work will be complied with. Subsequent issuance of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the code or of any other state or local laws or ordinances. Signature: Operator: JD Printed By: JD Print Date: 3/23/2007 Spokane Valleg, Community Development Permit Center 11707 E Sprague Ave, Suite ioMA Spokane Valley, WA 99206 (509)688-0036 FAX:(509)688-0037 UJ Residential Construction Permit Application 2D07 RI PERMIT NUMBER: PERMIT FEE: gNew Construction ❑ Addition/Remodel L Other: [] Accessory Bldg ❑ Deck SITE ADDRESS ASSESSORS PARCEL NO: 5Ss 32. 141/ Li LEGAL DESCRIPTION: Building Owner: Name: Zti YV\C.v; .A, C_ . T i . Wv.a„ i Address: 2/ y 7 ?L.n.h . City:‹. -ram kra , State: I — Zi yak i-� Phoney)5 .6 Li 3 Fax: Contact Person Name: Phone: t',� > �• =-� C Describe the scope of work in detail: Contractor: r Name: j Address:, / , f75.61.1- ,z .,i i; City / r State: w 7 . ✓ Z L 42/ Phone: G/ Y Fax: Contractor Lic No: V i-r Exp Date: W A City Business Lic. No: Id Cost of Projectlia-G:� y;: 1 1 _E y.; � too **************Tje followins MUST be complete: (write N/A if not applicable)********************** HEIGHT TO PE/).K: DI EI SIO i # OF STORIES: i TOTAL HCIIIT4BLE SPACE: MAIN FLOOR TO SQ. qc5 fe_J 1✓' 2Nu FLOOR FTG: v / 1, UNFIN BASEMENT SQ. FTG: h) ,-) IMPERVIOUS SURFACE AREA: FINISHED B,AIS MENT SQ. FTG: it �1 GARAGE SQ .FTG:, i S! ,=r . -F DECK/COV. PATIO SQ. FTG: Ai /- t 30% SLOPES ON / I P TY: �, ,'t # OF BEDROOMS: CONSTRUCTION TYPE: HEAT SOURCE: ( / �' SEWE f R SEPTIC? The permitee verifies, acknowledges and agrees by their signature that: 1) If this permit is for construction of or on a dwelling, the dwelling is/will be served by potable water. 2) Ownership of this City of Spokane Valley Permit inure to the property owner. 3) The signatory is the property owner or has permission to represent the property owner in this transaction. 4) All construction is to be done in full compliance with the City of Spokane Valley Development Code. Referenced codes are available for review at the City of Spokane Valley Permit Center. 5) This City of Spokane Valley Permit is not a permit or approval for any violation of federal, state or local laws, codes or ordinances. 6) Plans or additional information may be required to be submitted, and subsequently approved before this application can be processed. Signature Method of Payment: j Cash Bankcard #: Authorized Signature: REVISED 825/2005 ❑ Check ❑ Mastercard Expires: Date 6//, 0 VISA VIN#: 3o t PLANING On DATE: 34910-7 so` TREATED POST 4 - 16d GALV. PURLIN CONNECTION METHODS! A). NAILS EACH GIRT B). 2" X 6" GIRT (FLAT) TYPICAL GIRT CONNECTION NOTES FOR FLOOR PLAN CO INTERIOR FRAME WOOD POSTS, SEE POST SCHEDULE THIS SHEET GABLE WALL POSTS - 6" X 6" TYPICAL DOOR POSTS - 4" X 6' TYPICAL FOOTING DIMENSIONS, B + 1' 8"; D = 3' 0" MAXIMUM POST SPACING 12' 0" PURLINS @ 24" ❑.C., BEARING OR JOIST HANGERS (TYPICAL) 1- lD z W J WO 0- a. w tWo �� /- - -a 0 I N .-a f ti C ). SPANS 12' TO 60' ca DOUBLE TRUSSES to w Z > -+ Q!J 0. N • (3- CO x't N00! W V) BO w l7 o! DOUBLE TRUSSES A SINGLE TRUSS \_ \-® PLAN VIEW N.T.S. 12 NOTES FOR SECTION A -A R TYPICAL PURLIN, SEE FLOOR PLAN FOR SIZE Sz TRUSS DESIGN BY OTHERS 0 2' X 6' @ 24' D.C., 10' BAYS 2' X 6' @ 24' ❑.C., 12' BAYS DF-L #2 GIRTS FLAT @ 24' 0. C. 0 CONCRETE F❑❑TING, SEE SCHEDULE S5 EXTEND POST TO TOP OF PURLIN ROOF FASTENED TO PURLINS WITH 1 1/2' LONG WDDDFAST TEKS. WALLS FASTENED TO GIRTS WITH 1' LONG W❑ODFAST TEKS. 5 SEE FOOTING } DETAIL ''tifigt BUILDING SECTION A -A 0 2 4I 1 N.T.S. i 1 SINGLE OVERHEAD DOOR OPTION FRONT ELEVATION N.T.S. NOTES FOR FRONT ELEVATION CS HALF TRUSS DESIGN BY OTHERS SUPPORT PURLINS @ END TRUSS W/2" X 6" OR 2" X 8" STD JOIST HANGERS, LOWER TRUSS FOR END OVERHANG, IF REQ'D 0 2" X 10" HEADER 0 2" X 6" GIRTS @ 24' O.C., 10' BAYS, DF-L #2 2". X 6" GIRTS @ 24" O.C., 12' BAYS, DF-L #2 0 2" X 8" FACIA BOARDS 0 TREATED WOOD POSTS, SIZED PER SCHEDULE 0 OR ETREATED 2" 6"BOTTOM B10 T BOTTOM GIRT PURLINS MAY BE HUNG OFF THE TRUSS TOP CHORD FACES W/ STANDARD SIMPSON JOIST HANGERS OR EQUAL. PURLINS MAY BE BUTTED AND NAILED W/(2) 16d NAILS INTO EACH PURLIN. PURLINS MAY BE LAPPED AND NAILED• W/(3) 16d NAILS ON CONNECTION METHODS "B" AND "C", TOENAIL BACK SIDE OF PURLIN W/(1) 16d NAIL INTO EACH TOP CHORD MEMBER DETAIL 1 - TRUSS COLUMN CONNECTION, PURLIN SUPPORT N.T.S. /1 1" - 1601 NAILS 6", 8" OR 10" POST NAILING PATTERN . FOR POST LAMINATIONS NOTE: 2" X. 6" LAMINATE MUST BE A TREATED MEMBER AND MUST EXTEND TO THE BOTTOM OF THE FOOTING. LAMINATE MAY BE SPLICED ABOVE MID HEIGHT OF COLUMN NOTES FOR FOOTING DETAIL (a TREATED POSTS AS SIZED PER SCHEDULE 2 VIBRATE OR ROD CONCRETE TO OBTAIN FULL BEARING C UNDISTURBED SOIL FOOTING DETAIL GABLE END TRUSS 8 - 16d NAILS 2" X 6" X 18" BOLTING BLOCK 2" X 6" X 18" BOLTING BLOCK DETAIL 3 N.T.S. - 16d NAILS CORNER POST - 16d NAILS TYP. GABLE END TRUSS CONNECTION USE BOLTING BLOCKS BELOW ALL CORNER COLUMN GIRTS POPLIN METNC ONNec D "A' 7 oN NOTES FOR CONNECTION DETAIL O TRUSS TOP CHORDS TRUSS DESIGN BY TRUSS MANUFACTURER 0 PURLIN SUPPORT STRUT 2" X '4" X FULL DEPTH OF TOP CHORD PLUS PURLIN. NAIL PURLINS W/(3) 16d NAILS 0 NAIL STRUT TO TOP CHORD W/(3) 16d NAILS EACH SIDE, O MANUFACTURED TRUSS. NOTCH POSTS 1-1/2" EACH SIDE TO PROVIDE TRUSS SEAT. SS WOOD POST, SEE POST/FOOTING SCHEDULE. 0 4 - 40d GALV. NAILS IN PRE -DRILLED HOLES OR 3/4'0 MACHINE BOLT 0 SOLID BLOCKING AT CONNECTION POINTS. 0 TYP. PURLIN, SEE FLOOR PLAN FOR.. SIZE 0 2" X 6" OR 2" X 8" TOP GIRT 0 4 - 16d NAILS OR 3/4'0 M. BOLT DOUBLE OVERHEAD DOOR OPTION OPTIONAL FRONT ELEVATION N.T.S. SINGLE SLIDING DOOR OPTION OPTIONAL FRONT ELEVATION 12 N.T.S. S3 3068 MANDOOR OPTION •;r s. OPENING k OPTIONAL FRONT ELEVATION 12 N.T.S. SPLIT SLIDER DOOR OPTION OPTIONAL FRONT ELEVATION N.T.S. NOTES FOR OPTIONAL FRONT ELEVATIONS 0 HALF TRUSS DESIGN BY OTHERS 0 2" X 10" HEADER UP TO 12' 0" DOORS 2" X 12" HEADER UP TO 20' 0' DOORS 2" X 12" BACKED WITH 2" X 6" UP TO 24' 0" 0 2" X 6" HEADER 0 4" X 6" DOOR POST - 8' THRU 14' WALL HEIGHT W/ 2" X 6" FACER. 6" X 6" DOOR POST 16" & 18' WALL HEIGHT W/ 2" X 8" FACER. 0 DOUBLE 2" X 6" KINGPOST DETAIL 2 KNEE BRACE N.T.S. NOTES FOR DETAIL 2- KNEEBRACE 0 TRUSS TOP ..CHORD, DESIGN BY OTHERS 0 TRUSS BOTTOM CHORD, DESIGN BY OTHERS. 0 2" X 6' DF-L #2 EACH SIDE 0 WOOD POST, SEE P❑ST/FOOTING SCHEDULE SS 4 - 16d GALV. NAILS, EACH SIDE 1). KNEE BRACE REQUIRED WHERE SHOWN ON POST/FOOTING SCHEDULE. BRACE NOT REQUIRED AT GABLE END TRUSSES. 2). ALTERNATE KNEE BRACE/POST AND TRUSS/POST CONNECTION = USE 3/4"0 THRU BOLTS, EACH LOCATION. BUILDING SPECIFICATIONS: GENERAL - ALL BUILDING CONSTRUCTION SHALL CONFORM TO THE 2003 EDITION OF THE INTERNATIONAL BUILDING CODE (IBC 2003), AND ALL STATE & LOCAL BUILDING CODES. THESE SPECIFICATIONS AND PLANS ARE INTENDED FOR USE IN 30 OR 40 PSF LIVE LOAD, 85 MPH WIND SPEED, EXPOSURE B AND SEISMIC DESIGN CATEGORY C. DESIGN LOADS - ROOF LL = 30 OR 40 PSF ROOF DEAD LOAD = 5 PSF* CEILING LL = 0 PSF CEILING DL = 1 PSF * ROOF DL ALLOWS FOR A MAXIMUM OF 3" THICKNESS OF FIBERGLASS INSULATION. * MAXIMUM SOIL BEARING PRESSURE = 2,000 PSF MAXIMUM SOIL BEARING PRESSURE IS BASED ON SAND, SILTY SAND, CLAYEY SAND, SILTY GRAVEL A D CLAYEY GRAVEL SOILS OR BETTER. LESSER SOIL CONDITIONS WILL REQUIRE REVIEW AND FOOTING SIZE ADJUSTMENT BY TH ENGINEER. CONCRETE - MINIMUM 28 DAY COMPRESSIVE STRENGTH F'c = 2,000 psi, 4 SACK MIX FOR FOOTING . CAST IN PLACE CONCRETE CONSTRUCTION SHALL CONFORM TO ACI 318-99. WOOD - STRUCTURAL LUMBER SHALL CONFORM TO DF-L #2 OR BETTER BY WWPA GRADING RULES. MAXIMUM MOISTURE CONTENT SHALL BE 19% BY WEIGHT. NAILING SHALL CONFORM TO TABLE 2304.9.1 FASTENING SCHEDULE & OTHER APPROPRIATE SECTIONS OF CHAPTER 23 OF THE IBC. ALL NAILS INTO PRESERVATIVELY TREATED WOOD SHALL BE HOT -DIPPED ZINC COATED GALVANIZED STEEL, SILICONE BRONZE, COPPER OR STAINLESS STEEL. CCA TREATED WOOD SHALL CONFORM TO THE REQUIREMENTS OF AWPA STANDARDS C-16, C-22, C-23, C-24 & C-28. POSTS FOR BUILDINGS SHALL BE AS NOTED ON THE PLANS. ALL POST MATERIALS SHALL BE HEM -FIR #2 OR BETTER, FULL DIMENSION AND GRADED BY WWPA GRADING RULES. HARDWARE SHALL BE SIMPSON OR APPROVED EQUAL. ALL BOLTS SHALL CONFORM TO ASTM A307. METAL PANELS MAY BE DELTA RIB STYLE, GALVANIZED OR PAINTED, 29 GAUGE THICKNESS, ASTM A653 . STRUCTURAL QUALITY (SQ), Fy = 80.0 ksi. ROOF PANELS SHALL BE FASTENED TO PURLINS WITH PLATED, GASKETED 1 1/2" LONG METAL TO. WOOD FASTENERS. WALL PANELS SHALL BE FASTENED TO GIRTS WITH PLATED, GASKETED 1" OR LONGER METAL TO WOC'D FASTENERS. PANELS SHALL BE INSTALLED AND FASTENED ACCORDING TO THE MANUFACTURER'S RECOMMENDATIONS. SOIL COMPACTION - ALL BACKFILLED SOIL BENEATH FOOTINGS SHALL BE COMPACTED WITH A VIBRATORY COMPACTOR TO 95% OF THE PROCTOR DENSITY AS DETERMINED BY ASTM A1557, METHOD D. TRUSSES SHALL BE DESIGNED BY AND BEAR THE SEAL OF AN ENGINEER REGISTERED TO PRACTICE IN THE STATE IN WHICH THE BUILDING WILL BE CONSTRUCTED. TRUSS LOADING: TOP CHORD LIVE LOAD = 30 OR 40 PSF TOP CHORD DEAD LOAD = 5 PSF BOTTOM CHORD DEAD LOAD = 1 PSF TRUSS WEB BRACING INTERIOR OR GABLE END TRUSSES NOTES FOR TRUSS WEB BRACING. TRUSS DIAGRAMS WILL OFTEN REQUIRE WEB MEMBER BRACING, WHICH IS SHOWN ON TRUSS DRAWINGS FPS THE METHOD OF TRUSS WEB BRACING SHOWN ABOVE REPLACES 1" X 4" OR 2' X 4" WEB MEMBER BRACING FOLLOW THESE INSTRUCTIONS FOR ALL WEB MEMBER BRACING TO REPLACE "RAT -RUN' WEB l0d NAILS @ 6" O.C. "X6"OR2"X8" L-BRACE Od NAILS @ 6 O.C. " X 4' L-BRACE TRUSS WEB MEMBER TRUSS WEB MEMBER SECTION B-B SECTION B-B AT INTERIOR TRUSSES AT GABLE END TRUSS TYPICAL TRUSS BOTTOM CHORD BRACING NOTES FOR TRUSS BOTTOM CHORD BRACING 0 GABLE END TRUSS 0 DOUBLE INTERIOR TRUSSES 0 2" X 4" X-BRACING @ 10' 0" O.C. 0 2" X 4" BOTTOM CHORD BRACING @ 10'-0" O.C. OR, AS SPECIFIED BY TRUSS MANUFACTURER SS TOENAIL BRACES TO TRUSSES WITH 3 - 10d NAILS OVERHEAD DOOR OPENING SLIDING DOOR OPENING TYPICAL SIDE ELEVATION NOTES FOR SIDE ELEVATION 0 2" X 8" HEADER 0 2" X 10" HEADER FOR 10' & 12' SLIDING DOORS 2" X 8" HEADER FOR 8' & SMALLER SLIDING DOORS N.T.S. N.T.S. SHEATHING REQUIRMENTS THE FOLLOWING MINIMUM ROOF DIAPHRAGM REQUIREMENTS ARE NEEDED: MI ROOF STEEL: 29 G;UGE GRAND -RIB III, 36' WIDTH OR EQUIVALENT x FIELD SCREWS:':#1G x 1 1/2' AT 9' O.C. (NEXT TO HIGH RIB) X EAVE AND RIDGE. PURLIN SCREWS: #14 xl 1/2' AT BOTH SIDES OF EACH MAJOR RIB THE FOLLOWING MINIMUM ENDWALL DIAPHRAGM REQUIRMENTS ARE NEEDED: x ENDWALL STEEL: 29 GAUGE GRAND -RIB III, 36' WIDTH OR EQUIVALENT x FIELD SCREWS! #1U x .1 1/2' . € 9. O.C. (NEXT TO HIGH RIB) x BASE GIRT, END TRUSS, AND DOOR HEADER SCREWS' #14 x 1 1/2' 2 BOTH SIDES, OF EACH MAJOR RIB. DIAPHRAGM SCREWS DIAPHRAGM SCREWS E ENDWALL BASE GIRT ACROSS EAVE &`RIDGE PURLINS ON ROOF END TRUSS TOP CHORD, DIAPHRAGM ABOVSCREWS) TYPICAL SCREW PATTERN, EXCEPT As - NOTED STEEL SHEETING SCREW PATTERNS N.T.S i41410 EXPIRES 12/29/07 POST/FOOTING SCHEDULE 12' - 24' SPANS, 30 & 40 PSF LIVE LOAD POST COLUMN FOOTING KNEE BRACE CONCRETE SPACING WXD "B" DIA. "T" REQUIRED VOLUME, YD3 10'-0" 10'-0" 10'-0" 10'-O" .. 10'-o" 10.-0" 8'-0" 10'-0" 12.-0„_ 14'-0" 16'-0" 18'-0" 6"X6" 6"X6" 6" X 6" 6" X 6" W/2" X 6" 6" X 8" 6"X10" 6" X 10" 18" 18" 18" 18" 20" 20" 21" 3'-0" 3'-0" 3'-0" 3'-0" 3'-0" 3'-0" 3'-0" NO NO NO NO NO NO NO 0.20 0.20 0.20 0.20 0.24 0.24 0.27 12-0" 12-0" 12-0" 12 0" 12-0" 12-0" 8.,0" 10'-0" 12'-0" 14'-0" 16'-0" 18'-0" 20'-0" 6"X6 6"X 6. 6"X6"W/2"X6" 6" X 6" W/2" X 6" 6"X8"W/2"X6" 6" X 8" W /2"X6" 6" X 10" W/2" X 6" 26" 26" 26" 26" 26" 26" 26" 3'-0" 3'-0" 3'-0" 3'-0" 3'-0" 3'-0" 3'-2" NO NO NO NO NO NO NO 0.41 0.41 0.41 0.41 0.41 0.41 0.44 POST/FOOTING SCHEDULE 30' SPANS, 30 & 40 PSF LIVE LOAD POST COLUMN FOOTING KNEE BRACE CONCRETE SPACING 10'-0" 10'-0 , 10'-0" 10'-0" _ ..H.. 8'-0„ 12'-0" 14'-0" 18'-0" 22'-0" 24'-0 WXD 6" X 6" 6'. ken -- 6" X 6" W/2" X 6" 6"X6"W/2"X6" 6"X8"W/2"X6" 6"X8"W2"X6" 6" X 10"W/2" X 6" 6" X 12" "B" DIA. 26" 26" 26" 26" 26" 26" 26" 26" "T" 3'-0" 3'-0" 3'-0" 3'-O" 3'-0" 3%.2" 31.311 REQUIRED NO kJ -- NO_..._ NO NO NO NO. NO VOLUME, YD3 0.41 0.41 0.41 0.41 0.41 0.41 0.41 0.44 0.45 12-0" 12-0" 12-0" 12-0" 12-0 12-0" 8'-0" 10'-0" 12'-0" 14'-0" 16'-0" 18'-O" 22'-0" 24'-0" 6" X 6" 6"X6" 6" X 6" W/2" X 6" 6" X 8" 6"X8"W/2"X6" 6"X 10" - 6"X12" 6" X 12" W/2" X 6" 6"X12" 28" 2828" 28" 28 28" 28" 28" 28" 3'-0" 3'-0" 3'-0" 3'-0" 3'-2" 3'-6" NO NO NO NO 0.47 0.47 0.47 0.47 0.47 0.47 0.47 0.6 0.56 POST/FOOTING SCHEDULE 36' SPANS, 30 & 40 PSF LIVE LOAD POST COLUMN FOOTING KNEE BRACE CONCRETE SPACING .,H.. WXD "B" DIA. "T" REQUIRED VOLUME, YD3 10'-0" 10'-0" 10,-0„ loco" 10'-0" 10'-0' 8'-O" 10'-0" 12'-0" 14'-0" 18'-0". 20'-0" 22'-O ' 24'-0" 6"X6" 6" X 6" 6"X6"W/2"X6" 6"X6"W/2 X 6" 6" X 8" 6" X 8'•W/2"-X 6" 6"X10" 6" X 10" W/2" X 6" 6" X 10" W/2" X 6" 28" 28" - 28" 28„ ~28" 28" 28" 28" 3'-0" 3'-0" 3'-0" 3'-0" 3'-0" 3'-0" 3'-0" 3'-2" NO NO NO NO- --.___ NO NO NO NO YES 0.47 0.47 0.47 0.47 0.47 0.47 0.47 0.47 0.60 12-0" 12-0'' - - 12-0" 12-0 12-0" 12-0" -12-0" 12-0 12-0 8.-0" 10'-0" 18'-0" 22'-0" 24'-0" 6" X 6" 6"X6" _ 6" X 6" W/2"_. X 6" 6" X 8 /�V 6"X10" G 6" X 10"W/2" X 6" 6" X 12" 6" X 12" W/2" X 6" 32" 32" 32" 32" --32" 32" 32" 32" 3'-0" 3'-0" 3'-0" 3'-0" 3'-0" 3'-0" 3'-2" 3,;3„ NO NO NO NO NO NO NO NO - 0.62 0.62 0.62 0.62 0.62 0.62 0.62 0.66 0.68 POST/FOOTING SCHEDULE 40' SPANS, 30 8, 40 PSF LIVE LOAD POST COLUMN FOOTING KNEE BRACE CONCRETE SPACING 12-0" 12-0" 12-0" 12-0" 6" X 8" W/2" X 6" 6" X 10" W/2" X 6" 30" 30" 30" 30" 30" 30" 30" 30" 30" 6" X 6" 33" 6" X 6" 33" 314)11 3'-2" REQUIRED NO NO YES NO NO NO YES NO NO NO NO Rd- VOLUME, YD3 0.55 0.55 0.65 0.55 0.55 0.55 0.55 0.55 0.66 0.58 0.66 0.66 0.66 0.66 0.66 0.66 0.66 0.70 0.72 POST/FOOTING SCHEDULE 48' TO 62' SPANS, 30 & 40 PSF LIVE LOAD POST COLUMN FOOTING KNEE BRACE CONCRETE SPACING "B" DIA. REQUIRED VOLUME, YD3 6" X 8" W/2" X 6" 10'4" 12-0" 34" 34" 34" 34" 34 36" 36" 36" 36" 36" 36" 36" 36" 314111 NO NO NO YES YES NO NO NO NO NO 0.70 0.70 0.70 0.70 0.70 0.70 0.70 0.70 0.70 0.70 0.79 0.79 0.79 0.79 0.79 0.79 0.79 0.83 0.83 'POST/FOOTING SCHEDULE 64' TO 60' SPANS, 30 & 40 PSF LIVE LOAD POST COLUMN FOOTING KNEE BRACE CONCRETE SPACING "B" DIA. REQUIRED VOLUME, YD3 16'-0" 12-0" 12-0" 12-0" 6" X 10" 6" X 10" W/2" X 6" 6" X 10" W/2" X 6" 6" X 8" W/2" X 6" 6" X 10" W/2" X 6" 6" X 12" W/2" X 6" 36" 367 36" 36" 36" 36" 36" 36" 40" 4011 40" 40" 4011 4011 40" 31.411 31.011 314)11 31.011 31.011 3114)11 31.011 4011 40" 31.11.111 3'-2" NO NO NO NO NO YES YES NO 140 NO NO YES NO NO NO 0.79 0.79 0.79 0.79 0.79 0.79 0.79 0.79 0.83 0.97 0.97 0.97 0.97 0.97 0.97 0.97 0.97 1.03 NOTE: 1. THE NEXT LARGER SIZE POST MAY BE SUBSTITUTED FOR POSTS WITH 2" 6" LAMINATIONS. . ENDWALL POSTS SHALL BE 6" X 6" ROUGH CUT HEM -FIR #2 TREATED posTS -UP To 16*-0" WALL HEIGHT. ABOVE 16' WALL HEIGHT, ENDWALL POSTS SHALL BE 6" X 8" ROUGH CUT HEM -FIR #2 POSTS. 3. FOOTINGS FOR ENDWALL POSTS SHALL BE A MINIMUM OF 20"0 X 3'-0" DEEP FOR WALL HEIGHTS TO 16.-0". ABOVE 16' WALL HEIGHT, FOOTINGS SHALL BE 24"0 X V-4" DEEP. 4. ABOVE FOOTING DESIGNS ARE FOR POST FRAME BUILDINGS WITH CONCRETE FLOORS (CONTRAINED POSTS). IF BUILDINGS WILL NoT HAVE CONCRETE FLOORS, INCREASE FOOTING DIAMETER X 2" & FOOTING DEPTH X 4". WAMBEKE ENGINEERING 2913 E. 61st Court Daniel Wambeke, 'P. E. Spokane, WA 99223 LAYOUT, EJRUCTURAL DETAILS AND SPECIFICATIONS PCMT FRAME BUILDINGS 30 6,4 40 PSF LIVE LOAD TK ENTERPRISES P. O. BOX 18181 SPOKANE. WASHINGTON DESCRIPTION OF CHANGE DRAWN CHECKED BY DATE WAMBEKE 99228 DRAWING NO.1 REV. 5--05-06 TK ENT.IBC2003-06 SHEET, 1 OF 1 PROVIDE DIAGRAMS AND ENGINEERING LAYOUTS FOR ROOF TRUSSES, BEAMS AND FLOOR SYSTEMS PRIOR TO FRAMING INSPECTIONS CITY COPY THIS BUILDING SUBJECT TO FIELD INSPECTION CORRECTIONS REVIEWED FOR C DE MPLIANCE SPOKANE VALLEY UILD1 GG DIVISION i7v 3 t j `�