2008, 03-11 Permit App 07003054 Dormers, Re-Roof-ExpiredProject Number: 07003054 Inv: I Application THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Project Information: Permit Use: ADD TWO DORMERS AND A TEAR OFF RE- Contact: TOMAC CONSTRUCTION ROOF Address: E 11504 BROADWAY C - S - Z: SPOKANE VALLEY, WA 99206 Setbacks: Front Left: Right: Rear: Phone: (509) 599-1340 Group Name: Site Information: Project Name: Plat Key: 001840 Name: OPPORTUNITY TR # 01-354 District: Sou Parcel Number: 45222.0723 Block: SiteAddress: 12823 E 4TH AVE Location:: CSV Lot: Owner: Name: DURHAM, ROBERT A Address: 12823 E 4TH AVE SPOKANE VALLEY, WA 99216-07 Zoning: UR-3.5 Urban Residential 3.5 Water District: Hold: ❑ Area: 43,200 Sq Ft Width: 0 Depth: 0 Right Of Way (ft): 0 Nbr of Bldgs: 1 Nbr of Dwellings: 1 Review Information: Date: 3/11/2008 Page 1 of 2 Review Building Plan Review Permits: Released By: Originally Released: 3/11/2008 By: TMEL : `U Operator: JD Printed By: jmm Print Date: 3/11/2008 Project Number: 07003054 Inv: 1 Application THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Building Permit Date: 3/11/2008 Page 2 of 2 Contractor: TOMAC CONSTRUCTION Firm: TOMAC CONSTRUCTION Address: 11504 E BROADWAY Phone: (509) 893-8680 SPOKANE WA 99206 This Application: Total Project: Description Grp Type Notes Su Ft Valuation Se Ft Valuation 1&2 FAMILY R-3 VB 2 0 $4,500.00 0 $4,500.00 DORMERS/ TEAR OFF RE -ROOF Item Description RESIDENTIAL PERMIT FEE WSBC SURCHARGE SF PLNS RVW < 7999 SQ FT Notes: Payment Summary: Permit Type Building Permit Totals: 0 $4,500.00 0 $4,500.00 Units Unit Desc 1 SELECT 1 SELECT 1 SELECT Permit Total Fees: Fee Amount $111.25 $4.50 $44.50 $160.25 Fee Amount Invoice Amount Amount Paid Amount Owino $160.25 $160.25 $0.00 $160.25 $160.25 $160.25 $0.00 $160.25 Disclaimer: Submittal of this application certifies the owner (or person(s) authorized by the owner) has both examined and finds the information contained within to be true and correct, and agrees that all provisions of laws and/or regulations governing this type of work will be complied with. Subsequent issuance of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the code or of any other state or local laws or ordinances. Signature: Operator: JD Printed By: jmm Print Date: 3/11/2008 Spokane Valley 11703 E Sprague Ave, Suite B-3 Spokane Valley, WA 99206 (509)688-0036 FAX: (509)688-0037 kanevalle .or EdVE c on ew Construction AUG 0 :i iAddition/Remodel _ r Other:. Community Development Residential Constr Permit Applicatio SITE ADDRESS:f�- PERMIT N l MJ K: PERMIT FEE: Accessory Bldg Deck ASSESSORS PARCEL NO: LEGAL DESCRIPTION: Building Owner ....40bpiliv.- lam , Name: Address: , '� i3 4f� Q City: SPo ,cit,e. Vt( State: (�4 Zip: igZl� Phone: ,1 ZZ - 1 ,7� r Fax: otitact Peron Name: Phone: or Tors 001161 043 or ortoku Describe the scope of work in detail: Proposed Use:M31r -O ad^* Contractor .. X Name: 30 s er;va Address: C II Sp, Qrd. j (� State City: 40 0 kj Ql�l { ,� Zip: �`fic.S� Phone: `01 sift( 13440 Fax: Contractor Lic No: Exp Date: City Business Lic. No: d % Cost of Project: $ et' 5 ,O **************The following MUST be complete: (write N/A if not applicable)********************** HEIGHT TO 'T DIMENSIONS: # OF STORIES: --? TOTAL HABITABLE SPACE: MAIN FLOOR TO SQ. FTG: ,,, n ,�; ^, 2Nu FLOOR SQ. FTG: r ' ,,. L UNFIN BASEMENT SQ. FTG: IMPERVIOUS SURFACE AREA: 4 FINISHED BASEMENT:. SQ. FTG: '��"h GARAGE.SQ. FTG: F`� DECK/COV,,. PATIO SQ. FTG: 30% SLOPES ONp PROPERTY: J\I irk # OF BEDROOMS: CONSTRUCTION TYPE ;..5 HEAT SOURCE: SEWER 0,R ! !' SEPTIC? ,. The permitee verifies, acknowledges and agrees by their signature that: 1) If this permit is for construction of or on a dwelling, the dwelling is/will be served by potable water. 2) Ownership of this City of Spokane Valley Permit inure to the property owner. 3) The signatory is the property owner or has permission to represent the property owner in this transaction. 4) All construction is to be done in full compliance with the City of Spokane Valley Development Code. Referenced codes are available for review at the City of Spokane Valley Permit Center. 5) This City of Spokane Valley Permit is not a permit or approval for any violation of federal, state or local laws, codes or ordinances. 6) Plans or additional information may be required to be submitted, and subsequently approved before this application can be proc-ssed. SIGNATURE: Method of Payment: 7 Cash 3ankcard #: Authorized Signature: REVISED 2/15/07 Check ❑ Mastercard Expires: DATE: 7/42/07 ❑ VISA VIN#: 40.°Valle3' Site Address: 12823 E 4TH AVE Parcel Number: 45222.0723 Zoning: UR-3.5 Fire District: FD 01 Project Transmittal City of Spokane Valley Community Development Department 11703 E. Sprague Ave, Suite B3 Spokane Valley, WA 99206 Phone: 509.688.0036 New project Previous pre-app meeting Plan revisions ❑ ❑ Transmittal Date: Monday, August 06, 2007 Water District: Project Number: 07003054 Applicant: e-mail: Contact: e-mail: Contractor: TOMAC CONSTRUCTION E 11504 BROADWAY SPOKANE VALLEY, WA 99206 (509) 599-1340 TOMAC CONSTRUCTION E 11504 BROADWAY SPOKANE VALLEY, WA 99206 (509) 599-1340 TOMAC CONSTRUCTION 11504 E BROADWAY SPOKANE WA 99206 (509) 893-8680 Owner: DURHAM, ROBERT A 12823 E 4TH AVE SPOKANE, WA 99216-0708 e-mail: Occupant: e-mail: Arch / Engineer: e-mail: Project Description: ADD TWO DORMERS AND A TEAR OFF RE -ROOF Building Landuse Engineer Utilities Health Fire Dist Assessor PLAN REV SIGN OF F Please send all plan review and project comments via e-mail to the highlighted individuals. Siit1n� jUalley Site Address: 12823 E 4TH AVE Parcel Number: 45222.0723 Zoning: UR-3.5 Fire District: FD 01 Project Transmittal City of Spokane Valley Community Development Department 11703 E. Sprague Ave, Suite B3 Spokane Valley, WA 99206 Phone: 509.688.0036 New project Previous pre-app meetin Plan revision Transmittal Date: Thursday, September 13, 2007 Water District: Project Number: 07003054 Applicant: TOMAC CONSTRUCTION E 11504 BROADWAY SPOKANE VALLEY, WA 99206 (509) 599-1340 e-mail: Contact: TOMAC CONSTRUCTION E 11504 BROADWAY SPOKANE VALLEY, WA 99206 (509) 599-1340 e-mail: Contractor: TOMAC CONSTRUCTION 11504 E BROADWAY SPOKANE WA 99206 (509) 893-8680 Owner: DURHAM, ROBERT A 12823 E 4TH AVE SPOKANE, WA 99216-0708 e-mail: Occupant: e-mail: Arch / Engineer: e-mail: Project Description: ADD TWO DORMERS AND A TEAR OFF RE -ROOF Building Landuse Engineer Utilities Health Fire Dist Assessor REVISED PLAN ce) Please send all plan review and project comments via e-mail to the highlighted individuals. Page 1 of 1 Tom Melbourn From: Tom Melbourn Sent: Wednesday August 08, 2007 10:44 AM To: 'divinecorpll@yahoo.com' Subject: Reroof & Dormer addition Permit App #07-003054 The plans submitted do not have the following details: (1) Floor Joist size and on center distance (2) Bearing wall placement for attic floor joists (3) Stair detail (4) Purlin (2x4) wall support below floor (5) Rafter size and on center distance for main roof (6) Point load for dormer window from post above (7) Ridge beam support post trace to ground (8) Dimensions of dormers (9) Window sizes (10) Header sizes (11) Insulation (12) Wall detail (13) Radon system (14) Room purposes for dormers (15) Egress windows (16) Beam size support for dormer walls that is not over spanned (17) Etc. The plans you submitted are conceptual and not suitable for construction. The bearing points must be traced all the way to the ground, which may require additional footing or pier supports. You may be better off tearing off the roof and using engineered trusses, but point loads may be a problem. If you have any further questions please call me at (509) 688-0044 or email me at the above address Thank you for your cooperation. Tom Melbourn, Plans Examiner City of Spokane Valley 8/8/2007 Hopefully there is enough information included, but let me know if anything else is needed. I may be confused as to the exact framing of what you are doing, but if I am not the following issues are noted: (1) The (2) 2x12 center ridge beam (33'6") is over spanned. The center ridge beam will not span further than 16' between supports, calcs are included for the loading at the three sections. (2) The (2) 2x3 @ 16" o.c. floor joists are over spanned under today's standards using a 4x4 @ 16" o.c. with 40 psf load. The floor joists will need to be increased to allow for the current load requirements. The easiest solution I see is to attach a new 2X6 to each side and create a "6x6" to meet the spans required. (3) The 3 1/8" x 9" Glulam Beam with the ridge beam point load must be sized by vendor. The beams and headers were sized for dimensional lumber but can be switched if desired. (4) Are all of the windows 42" x 42" and are the headers (2) 2x10? The headers have been sized and included on the plan. (5) Do the bearing posts for the Glulam Beam have direct bearing through the basement to the cement footings? The new columns will be installed over bearing walls and additional solid blocking will be included between the joists to distribute the new loads. (6) Are you using ceiling joists in the dormers? (Insulation for attic space is R38 or vaulted R30 and a minimum 7 ft ceiling clearance is required.) The new upper level ceiling height will be 7' and the attic will be insulated to a R38 value. (7) It is unknown whether the purlin bearing wall for the existing roof rafters is direct bearing to the basement, and if not the roof rafters may be over spanned and may even be over spanning the existing floor joists. The existing roof framing has been left unmodified as much as possible. The new framing and loads have been accounted for and will be distributed, as much as possible, over existing framed bearing walls. (8) A wall detail from basement footing to roof covering showing dimensions of sheathing, etc. is required. Details have been included for the intended modifications. The existing components of the basement and first floor should be adequate given the magnitude of the new loads. (9) A floor plan for main floor and the basement with dimensions would facilitate point loading locations. The largest of the new point loads is only 2.15 kip and each new point load will be distributed through multiple members of both floor framing and wall framing. S"T'oka.ne�` P Valle 3' PERMIT CENTER Project Transmittal 11703 E Sprague Ave. Suite B-3 Spokane Valley WA 99206 Phone: 509.688.0036 Fax: 509.688.0037 New Application/Pre-Application ❑ Provide one of the following jpEQUIRED FOR ACCEPTANCE): Response to Review Comments ❑ PLUS Project #: 9 - Ck-;t-1 Revisions to Application ,p,i Parcel Number: Other (Describe Below): ❑ Site Address: / f,?3 f L//77 9�1(,, Route to (Please check all that apply): Division # of Sheets/ Type of Document/ # of Copies Building QC Check by: Development Engineering QC Check by: 13,4,2 / / / Planning SV Fire Department QC Check by: Received by: VERIFIEDi�ALS VERIFIED/INITIALS 0 VERIFIED/INITIALS 0 0 0 0 VERIFIED/INITIALS 0 0 0 0 Project Contact Information: Name: Email: Phone: Fax: Relationship to Project: ❑ Architect ❑ Engineer ❑ Other Design Professional ❑ Contractor ❑ Owner/Applicant DATE STAMP: iitC.,tfVtV u I CITY OF SPOKANE VALLEY MAR 10 2000 PERMIT CENTER BY: Y i i ?l` r s i3..5 5 --I Spokane �Valleyu Community Development Building Division 11703 E Sprague Ave Suite B3 Spokane Valley WA 99206 PROJECT INSPECTION RECORD Inspection Request Line: 509-688-0054 All inspections are scheduled through this line THIS CARD MUST BE POSTED ON THE JOB SITE AT THE TIME OF INSPECTION PROJECT NO: 1- 30544 PROJECT ADDRESS: 1 2-823 2- `A - Inspection Date Notes Corrections Left? Approved Inspector SETBACKS FOOTINGS REINFORCEMENT UNDERGROUND RADON SHEAR/BRACE WALL SHEATHING HOLDDOWNS FRAMING GAS PIPING DUCT WORK WATER PIPING DRAIN/WASTE/VENT INSULATION CEILING GRID FIREWALL/GWB FIRE PROTECTION HVAC HOOD/DUCT OTHER REQ: FINAL: FIRE FINAL: PLANNING FINAL: ENGINEERING FINAL: BUILDING CITY OFvr Spokane �Va11eyA Community Development Building Division 11703 E Sprague Ave Suite B3 Spokane Valley WA 99206 Inspection Request Line: 509-688-0054 All inspections are scheduled through this line THIS CARD MUST BE POSTED ON THE JOB SITE AT THE TIME OF INSPECTION ***Inspection requests must be scheduled before 7:00 am the morning of the desired date of inspection*** To call in an inspection request: 1. Call the Inspection Request line: 509-688-0054 2. When prompted, indicate your inspection area as checked below: X EAST AREA Press "1" SOUTH AREA Press "2" NORTH AREA Press "3" 3. Leave the following information: Project number: `7-'3OS —4/ Project Address: AvlS>c5, 4 - Type of Inspection Your phone number Your preference for AM or PM inspection time *** Special arrangements for access *** The inspector will make every effort to accommodate your preference. Depending on workload, the inspector cannot guarantee AM or PM inspection. 4. To speak directly with the inspector, please call their direct line between 7:00 am-7:30 am. COY - f) Psi XX 3'-0" 7'-6" 0 H.45Q _ I IddB1B 'n BMR �I tldLL 2' BADiRO 16'-6" Lo I AM o see SECOND FLOOR — NEW FLOOR PLAN COL.. . N,) r 'Nol*- 4 , ( rq FkeO ?tory\ i\Vog 1 (2) 2X12 FOR NEW UPPER FLOOR WALL FRAMING. EXISTING FLOOR JOISTS, TYP. SECOND FLOOR FRAMING EXISTING FLOOR JOISTS: DOUBLE 2x3'S © 16" 0.C. OVER 1x6" PLANKS, TYP. EXISTING FIRST FLOOR INTERIOR WALL FRAMING, TYP. EXISTING CMU BASEMENT — UNCHANGED. pia- - ,._o. NEW 2x10 HEADER W/ DOUBLE 2x6 TRIMMERS 6'x4' WINDOW. NEW 2x6 RAFTERS 24" 0.C. W/ SIMPSON H2.5 CLIPS. NEW 2x12 RIDGE BEAM EA. DORMER. NEW INTERIOR FRAMING, TYP EXISTING ROOF FRAMING TO REMAIN BETWEEN NEW DORMERS. NEW 2x6 FRAMED WALL. NEW 2x6 FRAMED WALL. / NEW 2E10 HEADER DOUBLE 2x66TRIMMERS S 3'-6" SQ. WINDOW. r.- -I I =I Ii� I NEW 2x FRAMED Mil iHi LNEW 3 GLULAM /8"x9 HEAIDENqw 2x4 R COLUMN, COLMN11Ml�, TYP. EXIS SUP WAL ING ORT 'Y AFTER STUB . E EXISTING Ci l NEY. 1 N EXISTING EXTERIOR WALL FRAMING, TYP. ROOF FRAMING NEW 2x12 RIDGE BEAM © EA. DORMER. NEW 2x6 RAFTERS 24" 0.C. W/ SIMPSON H2.5 CLIPS. NEW DOUBLE 2x12 RIDGE BEAM. EXISTING ROOF FRAMING. 0 CA 7 RI 4 Nc rB - Txt Ty EWE mica BE4 WADES *sitcom—N.., ANC sum ucBRED P TABLE RS150) AMDQW JA STUD AS REQUIRED aneum NEW FRA_V_I\ G DETAILS, TYPICAL N.T.S. Page 1 of 1 Tom Melbourn From: Tom Melboum Sent: Wednesday, September 19, 2007 1:37 PM To: 'divinecorp@yahoo.com' Subject: Permit App #07-003054 Tori I may be confused as to the exact framing of what you are doing, but if I am not the following issues are noted: (1) The (2) 2x12 center ridge beam (33'6") is over spanned. (2) The (2) 2x3 @ 16" o.c. floor joists are over spanned under today's standards using a 4x4 @ 16" o.c. with 40 psf load. (3) The 3 1/8" x 9" Glulam Beam with the ridge beam point load must be sized by vendor. (4) Are all of the windows 42" x 42" and are the headers (2) 2x10? (5) Do the bearing posts for the Glulam Beam have direct bearing through the basement to the cement footings? (6) Are you using ceiling joists in the dormers? (Insulation for attic space is R38 or vaulted R30 and a minimum 7 ft ceiling clearance is required.) (7) It is unknown whether the purlin bearing wall for the existing roof rafters is direct bearing to the basement, and if not the roof rafters may be over spanned and may even be over spanning the existing floor joists. (8) A wall detail from basement footing to roof covering showing dimensions of sheathing, etc. is required. (9) A floor plan for main floor and the basement with dimensions would facilitate point loading locations. Maybe we need to sit down and talk or a new plan drawn to address my concems. Tom Melbourn, Plans Examiner (208) 688-0044 9/19/2007 11'-6" MAME EMS 16'-6" 7'-6" 3'-0" i 8'-6" 0 gSGII-I Ln mu p' k k ATIC AREA tze MAMEB DEEM 14'-0" 33'-6" SECOND FLOOR - NEW FLOOR PLAN VstonA. ?t‘DOVQ-, 2X \Z c\cor 202 CZ— kr; r •sz Y, t-strit aN §A, - X • S (2) 2X1 2 FOR NEW UPPER FLOOR WALL FRAMING. EXISTING FLOOR JOISTS, TYP. SECOND FLOOR FRAMING EXISTING FLOOR JOISTS: DOUBLE 2x3'S 0 16" 0.C. OVER 1x6" PLANKS, TYP. EXISTING FIRST FLOOR INTERIOR WALL FRAMING, TYP. EXISTING CMU BASEMENT — UNCHANGED. i/a• ®i._a. NEW 2x10 HEADER W/ DOUBLE 2x6 TRIMMERS © 6'x4' WINDOW. NEW 2x6 RAFTERS © 24" 0.C. W/ SIMPSON H2.5 CLIPS. \ NEW 2x12 RIDGE BEAM © EA. DORMER. NEW INTERIOR FRAMING, TYP. EXISTING ROOF FRAMING TO REMAIN BETWEEN NEW DORMERS. NEW 2x6 FRAMED WALL. NEW 2x6 FRAMED WALL. NEW 2x10 HEADER W/ DOUBLE 2x6 TRIMMERS © 3'-6" SQ. WINDOW. fI r NEW 2x6 FRAMED '... WALL. [ - -- _ `\ N N G�ULAM NW COLIiMN, W 3 1 HIEAD9 DOU BLEII EADER TYP. R 2x4 E EXISTIN> 5 WALL, PPORT -YR. I RAFT (STUB R E EKIS�TING CHIMNEY. EXISTING EXTERIOR WALL FRAMING, TYP. ROOF' FRAMING NEW 2x12 RIDGE BEAM © EA. DORMER. NEW 2x6 RAFTERS © 24" 0.C. W/ SIMPSON H2.5 CLIPS. NEW DOUBLE 2x12 RIDGE BEAM. EXISTING ROOF FRAMING. rw SIMS et6 o. W/ 11-1B IIpl.A➢PI /f eta NEW FRAMING DETAILS, TYPICAL N.T.S. Page 1 of 1 Tom Melbourn From: Tom Melbourn Sent: Wednesday, September 19, 2007 1:37 PM To: 'divinecorp@yahoo.com' Subject: Permit App #07-003054 Tori I may be confused as to the exact framing of what you are doing, but if I am not the following issues are noted: (1) The (2) 2x12 center ridge beam (33'6") is over spanned. (2) The (2) 2x3 @ 16" o.c. floor joists are over spanned under today's standards using a 4x4 @ 16" o.c. with 40 psf load. (3) The 3 1/8" x 9" Glulam Beam with the ridge beam point load must be sized by vendor. (4) Are all of the windows 42" x 42" and are the headers (2) 2x10? (5) Do the bearing posts for the Glulam Beam have direct bearing through the basement to the cement footings? (6) Are you using ceiling joists in the dormers? (Insulation for attic space is R38 or vaulted R30 and a minimum 7 ft ceiling clearance is required.) (7) It is unknown whether the purlin bearing wall for the existing roof rafters is direct bearing to the basement, and if not the roof rafters may be over spanned and may even be over spanning the existing floor joists. (8) A wall detail from basement footing to roof covering showing dimensions of sheathing, etc. is required. (9) A floor plan for main floor and the basement with dimensions would facilitate point loading locations. Maybe we need to sit down and talk or a new plan drawn to address my concems. Tom Melbourn, Plans Examiner (208) 688-0044 9/19/2007