2013, 11-08 Permit BLD-2013-2249 Email, Site PlanKaren Kendall From: Karen Kendall Sent: Friday, November 08, 2013 9:56 AM To: 'swaproperties@gmail.com' Cc: Jenny Nickerson; Tamara Faurot; Mike Turbak Subject: Requested site plan changes to proposed SF residence located at 15901 E 4th Avenue Attachments: BLD-2013-2249_Ping_requested_changes(11-8-13).pdf Hi, Shane. Please find the attached map with comments and requests for updates. The main comment relates to setbacks. The cantilever porches and eaves cannot extend into the setbacks more than 20%. This means on the side (east/west) lot lines the cantilever must be a minimum of 4 feet from all side property lines. Currently it shows closer than 4 feet when measured and at one point extending over the property line. Additionally, please reference the email below from Jenny regarding building code requirements for eaves in relation to property lines. Please submit 3 copies of Sheet A-4. If changes need to be made to Sheet A-3 or others, submit 2 copies. Please bring in all updated plans to Tamara at the Permit Center and reference permit number BLD-2013-2249. Thank you!! Karen Kendall City of Spokane Valley Permit Center 11703 East Sprague Avenue, Suite B-3 Spokane Valley, WA 99206 509.720.5026 direct 509.688.0037 fax www.spokanevallev.org Contents of this email and any reply are subject to public disclosure. From: Jenny Nickerson Sent: Friday, November 08, 2013 9:47 AM To: Karen Kendall Cc: Doug Powell Subject: Fire protection of eaves for residential construction If an eave associated with a residential project is located between 2' and 5' from a property line, 1-hour fire resistant construction is required on the underside of the eave as per 2012 IRC Table R302.1(1) as amended by Washington State unless: 1). Roof eave fire -resistance rating shall be permitted to be reduced to 0 hours on the underside of the eave if fire blocking is provided from the wall top plate to the underside of the roof sheathing. 2). Roof eave fire -resistance rating shall be permitted to be reduced to 0 hours on the underside of the eave provided no gable vent opening are installed. I've copied the subject Table from the IRC below, let me know if you have any questions. Thanks! JRN 1 TABLE R302.1(1) EXTERIOR WALLS EXTERIOR WALL ELEMENT MINIMUM FIRE -RESISTANCE RATING MI SEPARi Walls (Fire -resistance rated) 1-hour tested in accordance with ASTM E 119 or UL 263 with exposure from both sides (Not fire -resistance rated) 0 hours Proj ections (Fire -resistance rated) 1 hour on theundersideaf ? 2 (Not fire -resistance rated) 0 hours Openings in walls Not allowed N/A 25%maximum of wall area per story 0 hours Unlimited 0 hours Penetrations p11 Comply with Section R302.4 None required For IS: 1 foot = 304.8 mm N/A =Not Applicable a. Roof eave fire -resistance rating shall be penis tied to be reduced to 0 hours on the underside ofthe eave if fire blockingi: wall top plate to the underside of the roof sheathing. b. Roof eave fire -resistance rating shall be permitted to be reduced to 0 hours on the underside of the eave provided no gabl installed. Jenny Nickerson, CBO MCP Senior Plans Examiner City of Spokane Valley Permit Center 11703 E Sprague Ave, Suite B-3 Spokane Valley, WA 99206 ph: (509) 720-5316 jenny.nickerson@spokanevallev.org (Inset 2 J ELEGTRIGAL PLAN Scale 1/4"=1'-0" P/L P/L P/ S 00*02'38" W 127.50' / PX22' y1 TIC AQCESSI L -J SITE PLAN Scale 1/4"=1'-0" N 00*02'38" E 78.50' P/L /L P/L — P/L P/L P/L LEGEND PROPERTY LINE 1/2" REBAR W/ CAP 7317 Project # - g013 < RECEIVVED 11/5/2013 SCALE: SHEET: