Loading...
2006, 10-09 Permit App 06004012 Pole BldgProject Number: 06004012 Inv: 1 Application THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Project Information: Permit Use: 24 X 48 POLE BUILDING Contact: EXCALIBUR STEEL STRUCTURES INC Address: PO BOX 14991 C - S - Z: SPOKANE, WA 99214-0991 Setbacks: Front Left: Right: Rear: Phone: (509) 921-1300 Group Name: Project Name. Site Information: Plat Key: Name: Range Date: 10/9/2006 Page 1 of 3 District: East Parcel Number: 55192.0354 Block: SiteAddress: 17511 E 6TH AVE Location:: CSV Zoning: UR-3.5 Water District: Urban Residential 3.5 Area: 19,600 Sq Ft Width: 0 Nbr of Bldgs: 0 Nbr of Dwellings: 0 Review Information: Lot: Owner: Name: STUHLMILLER, AARON D & STA Address: 17511 E 6TH AVE GREENACRES, WA 99016 Hold: ❑ Depth: 0 Right Of Way (ft): 0 Review Flood Plain Released By: Originally Released: Building Plan Review 10/6/2006 By: amblake Released By: Driveway/Approach Originally Released: 10/6/2006 By: TMELBOU Released By: Originally Released: Septic Sys Review 10/9/2006 By: amblake Released By: Originally Released: 10/6/2006 By: amblake Operator: AMB Printed By: AMB Print Date: 10/9/2006 Project Number: 06004012 Inv: ,1 Application THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Landuse/Zoning/HE Conditions Permits: Date: 10/9/2006 Page 2 of 3 Released By: Originally Released: 10/9/2006 By: CJJANSSE Contractor: EXCALIBUR STEEL Address: PO BOX 14991 SPOKANE, WA 99214-0991 Description Grp Type Notes POLE BDLG U-I VB Item Description RESIDENTIAL PERMIT FEE ACCESSORY PLANS REVIEW WSBC SURCHARGE Building Permit Firm: EXCALIBUR STEEL STRUCTURE Phone: (509) 921-1300 This Application: Sq Ft Valuation 1,152 $21,888.00 Total Project: So Ft Valuation 1,152 $21,888.00 Totals: 1,152 $21,888.00 Units Unit Desc Operator: AMB Printed By: AMB SELECT SELECT SELECT Permit Total Fees: Print Date: 1,152 $21,888.00 Fee Amount $349.25 $87.31 $4.50 $441.06 10/9/2006 Project Number: 06004012 Inv:.1 Application THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Notes: All driveway approaches to be constructed per Spokane County Standards as adopted by the City of Spokane Valley. Minimum of 7.5' from each property line, 5' from crosswalks or intersection curb and minimum of 15' of separation between any two approaches. Flat portion of a residential approach to be minimum of 16' wide, maximum of 30' wide and combined approach width not to exceed 50% of total frontage. (A) THE BULDING OFFICIAL IS AUTHORIZED TO REQUIRE THE PERMIT APPLICANT TO PROVIDE FEE REIMBURSEMENT TO THE CITY OF SPOKANE VALLEY FOR ANY PROFESSIONAL SERVICES REQUIRED OUTSIDE OF CITY STAFF REVIEW. (B)ESOME EXAMPLES OF POTENTIAL OUTSIDE RESOURCES INCLUDE PLAN REVIEW, CONSTRUCTION INSPECTION AND SURVEYING. See plat file for TURTLE CREEK SOUTH 2ND for special drainage requirements Payment Summary: Permit Type Fee Amount Invoice Amount Amount Paid Building Permit $441.06 $441.06 $0.00 Amount Owine $441.06 $441.06 $441.06 $0.00 $441.06 Date: 10/9/2006 Page 3 of 3 Disclaimer: Submittal of this application certifies the owner (or person(s) authorized by the owner) has both examined and finds the information contained within to be true and correct, and agrees that all provisions of laws and/or regulations governing this type of work will be complied with. Subsequent issuance of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the code or of any other state or local laws or ordinances. Signature: Operator: AMB Printed By: AMB Print Date: 10/9/2006 Project Number: 06004012 Inv: .1 Area: 19,600 Sq Ft Width: 0 Nbr of Bldgs- 0 Nbr of Dwellings: 0 Review Information: - , Application THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Project Information: Permit Use: 24 X 48 POLE BUILDING Setbacks: Front Site Information: Plat Key: Left Right: Rear: Date: 10/6/2006 Page 1 of 2 Contact: EXCALIBUR STEEL STRUCTURES INC Address: PO BOX 14991 C - S - Z: SPOKANE, WA 99214-0991 Phone: (509) 921-1300 Group Name: Project Name: Name: Range District: East Parcel Number: 55192.0354 Block: SiteAddress: 17511 E 6TH AVE Location:: CSV Lot: Owner: Name: STUHLMILLER, AARON D & STA Address: 17511 E 6TH AVE GREENACRES, WA 99016 Zoning: UR-3.5 Urban Residential 3.5 Water District: Hold: ❑ Depth: 0 Right Of Way (ft): 0 Review Flood Plain Released By: Building Plan Review Released By: TM ciC) b (o / Driveway/Approach Released By: Septic Sys Review \ip\� Landuse/Zoning/HE Conditions Released By. Operator: AMB Printed By: AMB Print Date: 10/6/2006 TT Permit Center F' okane 11707 E Sprague Ave, Suite 106 �( J�7a1�� Spokane Valley, WA 99206 !'y (509)688-0036 FAX: (509)688-0037 Community Development www.sookanevallev.org.com Reroof Construction Permit Application SITE ADDRESS 17 5 I 1 F - 011- N.31l0ERk ev oc1 o ;O Commercial \LD Rtes dentia1 ASSESSORS PARCEL NO: •551 T Z , 63 5 L% LEGAL DESCRIPTION: Buildin 'owne`r 4� � . `� r Name: An rp'ln S k (iv t 1 - Address: / 7 S I ( E City:Cr-p 4-e t-e, Zip: q % C / 6 Phone: Zs 6 — J 0 C./- ax: onta� r o ny 4.pt,Twf- ,Y} G ^tG Name: Pn.-..- ( Phone: 9 Z ( -- 13Q Contractor : rt• r :a Name: l :: r 15-1-r►i `!-�xN, .4-r-- . Address: P.. 0 . ( (L f j 5 j City:4zz,.F(jJ47 Zip: ljZ/V //7Z/-i3c0 Fax: 9Z(-&7/E Phone: Lic No: ExeMss2ZZ8 Exp. Date: OZ -e? City Business Lic No: Describe the scope of work in detail: O Tear off ❑ Overlay Cost of project DISCLAIMER The permitee verifies, acknowledges and agrees by their signature that: 1) If this permit is for construction of or on a dwelling, the dwelling is/will be served by potable water. 2) Ownership of this City of Spokane Valley Permit inure to the property'owner. 3) The signatory is the property owner or has permission to represent the property owner in this transaction. 4) All construction is to be done in full compliance with the City of Spokane Valley Development Code. Referenced codes are available for review at the City of Spokane Valley Permit Center. 5) This City of Spokane Valley Permit is not a permit or approval for any violation of federal, state or local laws, codes or ordinances. 6) Plans or additional information may be required to be submitted, and subsequently approved before this application can be processed. Ownership of resultin• development rights granted by any issued permit inure to the property owner. Signatu Date /4 - 5-O 6 Method of Payment: (F.xed permit - pplications will only be accepted with major bankcard) ❑ Cash 0 Check ❑ Mastercard ❑ VISA ❑ Other Bankcard #: Expires: VIN#: Authorized Signature: REVISED 8/232005 SRHD EHS 10/06/2006 07:49 5093241567 00 36 2006 08:47 FR Project litanbor. 06004012 luv: 1 Application THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a PitdrathiNgSi. permit Use: Gi X 48 POLE BUtLDWG Setbacks: lrout Left: Right Site Inform ati, Star - Plat Ke: r. Name: Range Rear Farce Number. 55192.0354 Block: '. dt eAddress: 17511 E 6TR AVE Location:: CSV Zoning: UR3.5 Water District: Area: 19,600 Sq Ft Width: 0 Nbt of Bldgs: 0 Nbr of Dwellings: 0 Review In/r'atation: s. 97ot d Plain Urban Residential 3.5 TO 3241567 Date: 10/6/2006 PAGE 01/01 P.01/03 e 1 of 2 Contact EXCALIBUR STEEL STRUC Address: PO BOX 14991 C - S - 2: SPOKANE, WA 99214.0991 Phone: (509) 921-1300 Group Name: Project Name: District East Lot Owner: Name: STUHLMILLER, AARON D & STA Address: 17511E 6 H AVE GREENACRES, WA 99016 Hold: 0 Dept 0 Right Of Way (ft): 0 Buil ding Plan Review Opra tar. AMB Printed By. AMB Print Date: 10/6/2006 OCT 06 2006 09:11 5093241567 PSGE.01 PLANNING DEPT. APPROVED BY: DATE. I°lV O t 4-x r 5 7 f/vim 177 OP' 0 O NOTES FOR FLOOR PLAN te INTERIOR FRAME WOOD POSTS, SEE POST SCHEDULE THIS SHEET 0 GABLE WALL POSTS - 6" X 6' TYPICAL DOOR POSTS - 4" X 6' TYPICAL FOOTING DIMENSIONS, B + 1' 8") D = 3' 0" MAXIMUM POST SPACING 12' 0" PURLINS @ 24' O.C., BEARING OR JOIST HANGERS (TYPICAL) C. X J O v 13 z t~- 0 O Li W 0 40 PSF LIVE LOAD @ 24' ❑.C. - TYPICAL O 0 0 0 40 PSF LIVE LOAD W 0 el 0 I (U ti SPANS 12' TO 60' DOUBLE TRUSSES N z J A c Z = A a..J • W co 1 ?u W(1- (4o d- Q z� " J>' DC I- d I • U 00 p X•NI, cu (u W au N DOUBLE TRUSSES PURLIN CONNECTION METHODS' A). PURLINS MAY BE HUNG OFF THE TRUSS TOP CHORD FACES W/ STD, SIMPSON JOIST HANGERS OR EQUAL. B), PURLINS MAY BE BUTTED AND NAILED W/(2) 16d NAILS INTO EACH PURLIN, C), PURLINS MAY BE LAPPED AND NAILED W/(3) 16dNAILS, tON CONNECTION METHODS "B" AND "C', TOENAIL BACK SIDE OF PURLIN W/C1) 16d NAIL INTO EACH TOP CHORD MEMBER SINGLE TRUSS RI \-® PLAN VIEW NOTES FOR SECTION A -A Si TYPICAL PURLIN, SEE FLOOR PLAN FOR SIZE 0 TRUSS DESIGN BY OTHERS 0 2' X 6' @ 24' O.C., 10' BAYS 2'X6'@24'O,C.,12'BAYS DF-L. #2 GIRTS FLAT @ 24' O.C. v 0 CONCRETE FOOTING, SEE SCHEDULE N 6 S5 EXTEND POST TO TOP OF PURLIN ROOF FASTENED TO PURLINS WITH 1 1/2' LONG WOODFAST TEKS. —. WALLS FASTENED TO •,� GIRTS WITH 1' LONG WOODFAST TEKS, TYP N.T.S, SEE FOOTING tiw DETAIL BUILDING SECTION A -A N,T,S, 20' 0" MAXIMUM SINGLE OVERHEAD DOOR OPTION FRONT ELEVATION NOTES FOR FRONT ELEVATION N.TS, CoHALF TRUSS DESIGN BY OTHERS SUPPORT PURLINS @ END TRUSS W/2" X 6" 0 TREATED 2' X 6' BOTTOM GIRT 0 2" X 10" HEADER 0 2" X 6" GIRTS @ 24" ❑,C,, 10' BAYS, DF-L #2 2" X 6' GIRTS @ 24" ❑,C,, 12' BAYS, DF-L #2 0 2" X 8" FACIA BOARDS S5 TREATED WOOD POSTS, SIZED PER SCHEDULE 0 TREATED 2' X 6" BOTTOM GIRT OR TREATED 2" X 10' BOTTOM GIRT DETAIL 1 - TRUSS COLUMN CONNECTION PURLIN SUPPORT NOTES FOR FOOTING DETAIL • TREATED POSTS AS SIZED PER SCHEDULE VIBRATE OR ROD CONCRETE TO OBTAIN FULL BEARING 10 UNDISTURBED SOIL FOOTING DETAIL TREATED POST CAL TRUSS BOTTOM CHORD BRACING NOTES FOR TRUSS BOTTOM CHORD BRACING (D.) GABLE END TRUSS (D DOUBLE INTERIOR TRUSSES GABLE END POST NAILS TO BOTTOM CHORD BRACE 4 16d GALV. NAILS EACH GIRT (2' X 6' OR 2' X 8' GIRT <FLAT> TYPICAL GIRT CONNECTION GABLE END TRUSS 16c1 NAILS BOLTING BLOCK 2' X 6' X 18' BOLTING BLOCK DETAIL 3 CORNER POST NOTES FOR CONNECTION DETAIL MANUFACTURED TRUSS TOP CHORDS TRUSS DESIGN BY TRUSS MANUFACTURER 0 PURLIN SUPPORT STRUT 2" X 6' X FULL DEPTH OF TOP CHORD PLUS PURLIN, NAIL PURLINS WW3) 16d NAILS NAIL STRUT TO TOP CHORD Wi(3) 16d NAILS EACH SIDE. O MANUFACTURED TRUSS - NAIL TO EACH SIDE OF POST WITH 4 - 16d NAILS ON TOP NAILING BLOCK 0 WOOD POST, SEE POST/FOOTING S&EDULE. Q.F.2) SOLID BLOCKING AT CONNECTION POINTS. TYP. PURLIN, SEE FLOOR PLAN FOR SIZE 415D KNEE BRACE, IF REQ'D. SEE POST SCHEDULE AND DETAIL 2 410 - 3/4' 0 MACHINE BOLT THRU TRUSS T. CHORD 1 - 3/4' 0 MACHINE BOLT THRU KNEE BRACE 1 - 3/4' 0 MACHINE BOLT THRU BOLTING BLOCK DOUBLE OVERHEAD DOOR OPTION OPTIONAL FRONT ELEVATION 16d NAILS TYR GABLE END TRUSS CONNECTION USE BOLTING BLOCKS BELOW ALL CORNER COLUMN GIRTS SINGLE SLIDING DOOR OPTION OPTIONAL 'FRONT ELEVATION OPTIONAL FRONT ELEVATION • DETAIL 2 KNEE BRACE OVERHEAD DOOR OPENING NOTES FOR DETAIL 2- KNEEBRACE (T1) TRUSS TOP CHORD, DESIGN BY OTHERS TRUSS BOTTOM CHORD, DESIGN BY OTHERS 2' X 6' KNEE BRACE orD WOOD POST, SEE POST/FOOTING SCHEDULE 0-iiD 2' X 6" OR 2" X 8" TRUSS SEAT EACH SIDE OF POST @ EACH KNEE BRACE CONNECTION (f;) NAIL KNEE BRACE TO POST WITH 4 - 16d NAILS giD NAIL BOLTING BLOCK TO POST BRACE WITH 8 - 16d NAILS NOTES' KNEE BRACE REQUIRED WHERE SHOWN ON POST/FOOTING SCHEDULE, BRACE NOT REQUIRED AT GABLE END TRUSSES, SLIDING DOOR OPENING NOTES FOR SIDE ELEVATION SLIDING DOORS SLIDING DOORS TYPICAL SIDE ELEVATION TRUSS WEB BRACING INTERIOR OR GABLE END TRUSSES NOTES FOR TRUSS WEB BRACING: TRUSS DIAGRAMS WILL OFTEN REQUIRE WEB MEMBER BRACING, WHICH IS SHOWN ON TRUSS DRAWINGS AS THE METHOD OF TRUSS WEB BRACING SHOWN ABOVE REPLACES l' X 4' OR 2' X 4" WEB MEMBER BRACING. FOLLOW THESE INSTRUCTIONS FOR ALL WEB MEMBER BRACING TO REPLACE 'RAT -RUN' WEB L-BRACE -BRACE TRUSS WEB MEMBER TRUSS WEB MEMBER SECTION B-B SECTION B-B AT INTERIOR TRUSSES AT GABLE END TRUSS BUILDING SPECIFICATIONS' GENERAL - ALL BUILDING CONSTRUCTION SHALL CONFORM TO THE 2003 EDITION OF THE INTERNATIONAL BUILDING CODE (IBC 2003) AND ALL STATE & LOCAL BUILDING CODES, THESE SPECIFICATIONS AND PLANS ARE DESIGNED FOR 30 OR 40 PSF LIVE (SNOW) LOAD, 85 & 90 MPH WIND SPEED, EXPOSURE B AND SESMIC DESIGN CATEGORY C. DESIGN LOADS - ROOF LL = 30 OR 40 PSF ROOF DEAD LOAD = 5 PSF)1( CEILING LL = 0 PSF CEILING DL = 1 PSF )1( ROOF DL ALLOWS FOR A MAXIMUM OF 3' THICKNESS OF FIBERGLASS INSULATION. )1( MAXIMUM SOIL BEARING PRESSURE = 2,000 PSF OPENING MAXIMUM SOIL BEARING F'RESSURE IS BASED ON SAND, SILTY SAND, CLAY, CLAYEY SAND AND SANDY GRAVEL OR BETTER PER IBC TABLE 18042. LESSER SOIL CONDITIONS \OLL REQUIRE REVIEW AND FOOTING SIZE ADJUSTMENT BY THE ENGINEER. CONCRETE - MINIMUM 28 DAY COMPRESSIVE STRENGTH Fic = 2,000 psl, 4 SACK MIX FOR FOOTINGS, CAST IN PLACE CONCRETE CONSTRUCTION SHALL CONFORM TO ACI 318-92, WOOD - STRUCTURAL LUMBER SHALL CONFORM TO DF-L #2 OR BETTER OR HEM -FIR #2 OR BETTER BY WWPA GRADING RULES, MAXIMUM MOISTURE CONTENT SHALL BE 19% BY WEIGHT, NAILING SHALL CONFORM TO TABLE 2304.9.1 & OTHER APPLICABLE SECTIONS OF CHAPTER 23 OF THE IBC, ALL NAILS INTO PRESERVATIVELY TREATED WOOD SHALL BE ZINC COATED HOT DIP GALVANIZED, SILICONE BRONZE, COPPER OR STAINLESS STEEL. CCA TREATED WOOD SHALL CONFORM TO THE REQUIREMENTS OF AWPA STANDARDS C-16, C-22, C-23, C-24 & C-28. POSTS FOR BUILDINGS SHALL BE AS NOTED ON THE PLANS, ALL POST MATERIALS SHALL BE HEM -FIR #2 OR BETTER, FULL DIMENSION AND GRADED BY WWPA GRADING RULES. HARDWARE SHALL BE SIMPSON OR APPROVED EQUAL. ALL BOLTS SHALL CONFORM TO ASTM A307, METAL PANELS MAY BE DELTA RIB STYLE, GALVANIZED OR PAINTED, 29 GAUGE THICKNESS, ASTM A653 STRUCTURAL QUALITY (SW, Fy = 80M ksl. ROOF PANELS SHALL BE FASTENED TO PURLINS WITH PLATED, GASKETED 1 1/2' LONG METAL TO WOOD FASTENERS. WALL PANELS SHALL BE FASTENED TO GIRTS WITH PLATED, GASKETED 11 OR LONGER METAL TO WOOD FASTENERS, PANELS SHALL BE INSTALLED AND FASTENED ACCORDING TO THE MANUFACTURER'S RECOMMENDATIONS. SOIL COMPACTION - ALL BACKFILLED SOIL BENEATH FOOTINGS SHALL BE COMPACTED WITH A VIBRATORY COMPACTOR TO 95% OF THE PROCTOR DENSITY AS DETERMINED BY ASTM A1557, METHOD D. TRUSSES SHALL BE DESIGNED BY AND BEAR THE SEAL OF AN ENGINEER REGISTERED TO PRACTICE IN THE STATE OF WASHINGTON. TRUSS LOADING' TOP CHORD LIVE LOAD = 30 OR 40 PSF 1" BOTTOM CHORD DEAD LOAD = 1 PSF SPLIT SLIDER DOOR OPTION OPTIONAL FRONT ELEVATION NOTES FOR OPTIONAL FRONT ELEVATIONS 0 HALF TRUSS DESIGN BY OTHERS 0 2" X 10" HEADER UP TO 121-0" DOORS WALL HEIGHT W/ 2' X 8' FACER. 2 - 16c1 NAILS 10" POST NAILING PATTERN FOR POST LAMINATIONS NOTE: 2" X 6" LAMINATE MUST BE A TREATED MEMBER AND MUST EXTEND TO THE BOTTOM OF THE FOOTING. LAMINATE MAY BE SPUCED ABOVE MID HEIGHT OF COLUMN SHEATHING REQUIRMENTS THE FOLLOWING MINIMUM ROOF DIAPHRAGM REQUIREMENTS ARE NEEDED' * ROOF STEEL' 29 GAUGE GRAND -RIB III, 36' WIDTH OR EQUIVALENT FIELD SCREWS' x 1 1/2' AT 9' O.C. <NEXT TO HIGH RIB) 111 EAVE AND RIDGE PURLIN SCREWS' 014 x/ 1/2' AT BOTH SIDES OF EACH MAJOR RIB THE FOLLOWING MINIMUM ENDWALL DIAPHRAGM REQUIRMENTS ARE NEEDED' ENDWALL STEEL' 29 GAUGE GRAND -RIB III, 36' WIDTH OR EQUIVALENT NI BASE GIRT, END TRUSS, AND DOOR HEADER SCREWS' #114 x 1 1/2' a BOTH SIDES OF EACH MAJOR RIB. DIAPHRAGM SCREWS DIAPHRAGM SCREWS ENDWALL BASE GIRT ACROSS ENDVALL DOOR] HEADERS & GABLE END TRUSS TOP CHORD, EAVE & RIDGE PURLINS ON ROOF tIsraRiVINREWSJ TYPICAL SCREW PATTERN, EXCEPT AS STEEL SHEETING SCREW PATTERNS EXPIRES 12/29/07 POST/FOOTING SCHEDULE 17 - 24' SPANS, 30 & 40 PSF LIVE LOAD POST COLUVIN FOOTING KNEE BRACE CONCRETE SPACING "Fr. w x D "Fr DIA. "r REQUIRE) VOLUME, YD3 POST/FOOTING SCHEDULE 30' SPANS, 30 & 40 PSF UVE LOAD POST COLUMN FOOTING KNEE BRACE CONCRETE SPACING "Er' W X D "B" DIA. "r REQUIRED VOLUME, YD3 POST/FOOTING SCHEDULE 36' SPANS, 30 & 40 PSF UVE LOAD POST COLUMN FOOTING KNEE BRACE CONCRETE NO 0.47 POST/FOOTING SCHEDULE 40' SPANS, 30 & 40 PSF UVE LOAD POST COLUMN FOOTING KNEE BRACE CONCRETE POST/FOOTING SCHEDULE 48' TO 67 SPANS, 30 & 40 PSF UVE LOAD POST COLUMN FOOTING KNEE BRACE CONCRETE SPACING "Fr' W X D "B" DIA. ..r REQUIRED VOLUME, YD3 0.76 POST/FOOTING SCHEDULE 64' TO 60' SPANS, 30 & 40 PSF UVE LOAD POST COLUMN FOOTING KNEE BRACE CONCRETE SPACING "Er. w x D "B" DIA. "r REQUIRED VOLUME, YD3 0.79 NOTE: 1. THE NEXT LARGER SIZE POST MAY BE SUBSTITUTED FOR POSTS WITH 2" X 6" LAMINATIONS. 2. ENDWALL POSTS SHALL BE 6" X 6" ROUGH CUT HEM -FIR #2 TREATED POSTS UP TO 16'-0" WALL HEIGHT. ABOVE 16' WALL HEIGHT, ENDWALL POSTS SHALL BE 6" X 8" ROUGH CUT HEM -FIR #2 POSTS. 3. FOOTINGS FOR ENDWALL POSTS SHALL BE A MINIMUM OF 18"01 X 3'-0" DEEP FOR WALL HEIGHTS TO 1 61-0". ABOVE 16' WALL HEIGHT, FOOTINGS SHALL BE 24"0 X 3'-4" DEEP. 4. ABOVE FOOTING DESIGNS ARE FOR POST FRAME BUILDINGS WITH CONCRETE FLOORS (CONTRAINED POSTS). IF BUILDINGS WILL NOT HAVE A CONCRETE FLOOR, INCREASE FOOTING DIAMETER X 2" 8c FOOTING WAMBEKE ENGINEERING 2913 E. 61st Court Daniel Wareibeke, P. E. Spokane, WA 99223 STRUCTURAL DESIGN FOR POST FRAME BUILDINGS EXCALIBUR STEEL STRUCTURES, INC. P. O. BOX 14991 SPOKANE, WASHINGTON 99214-0991 BY DRAWN WAMBEKE REV BY DATE DESCRIPTION OF CHANGE CHECKED DATE 01-08-06 DRAWING NO.' PROJECT 2006 SCALE' N.T.S. SHEET' 1 OF 1 REV. 8' 0' T❑ 14' 0' EAVE HEIGHTS PURLIN SIZES AND SPACING USE 2' X 6' DF-L #2 @ 24' O.C., 8' BAYS USE 2' X 6' DF-L #2 @ 24' O,C., 10' BAYS USE 2' X 8' DF-L #2 @ 24' O.C., 12' BAYS PURLIN CONNECTION METHOD PURLINS WILL BE HUNG FROM LEAN TO RAFTERS WITH STANDARD SIMPSON JOIST HANGERS OR EQUAL. NOTES FOR LEAN TO CONNECTI❑N DETAIL S1.MANUFACTURED TRUSS NOTCH POSTS 1-1/2' EACH SIDE TO PROVIDE TRUSS SEAT, 0 TRUSS SUPPORT POST. SEE POST/FOOTING SCHEDULE. 0 3/4' DIA. MACHINE BOLT S4O 2' X 6' X 24' DF-L CONNECTION BLOCK. PROVIDE BLOCK EACH SIDE OF POST. S5 TYP. PURLIN. SEE CHART AT LEFT FOR SIZES. 0 2' X 6' OR 2' X 8' EAVE GIRT - JOIST HANG 0 2' X 6' DF-L GIRTS @ 24' O.C.. TYPICAL 8', 10' OR 12' BAYS SB 6' X 6' FULL SIZE LEAN TO POST OD 16d NAILS ® LEAN-TO RAFTERS - SEE CHART & SECTION A -A 11 6' X 6' X 36' BOLTING BLOCK NOTES FOR LEAN TO GIRTS GIRTS ARE NOT REQUIRED FOR SUPPORT OF POSTS, BUILDING LEAN TO'S MAY BE OPEN OR ENCLOSED USE 2' X 6' DF-L #2 GIRTS @ 24' ❑.C. FOR 8' BAYS USE 2' X 6' DF-L #2 GIRTS @ 24' O.C. FOR 10' BAYS USE 2' X 6' DF-L #2 GIRTS @ 24' ❑.C, FOR 12' BAYS LEAN-TO ADDITION TO POST FRAME CONTINUOUS ROOF SLOPE BUILDING SPECIFICATIONS:. GENERAL - ALL BUILDING CONSTRUCTION SHALL CONFORM TO THE 2003 EDITION OF THE INTERNATIONAL BUILDING CODE (IBC 2003), AND ALL STATE & LOCAL BUILDING CODES. THESE SPECIFICATIONS AND PLANS ARE INTENDED FOR USE IN 30 OR 40 PSF LIVE (SNOW) LOAD, 85 MPH WIND SPEED, EXPOSURE B AND SEISMIC DESIGN CATEGORY C. DESIGN LOADS - ROOF LL = 30 OR 40 PSF ROOF DEAD LOAD = 5 PSF* CEILING LL = 0 PSF CEILING DL = 1 PSF * ROOF DL ALLOWS FOR A MAXIMUM OF 3" THICKNESS OF FIBERGLASS INSULATION. * MAXIMUM SOIL BEARING PRESSURE = 2,000 PSF MAXIMUM SOIL BEARING PRESSURE IS BASED ON SAND, SILTY SAND, CLAYEY SAND, SILTY GRAVEL AND CLAYEY GRAVEL SOILS OR BETTER PER IBC TABLE 1804.2. LESSER SOIL CONDITIONS WILL REQUIRE REVIEW AND FOOTING SIZE ADJUSTMENT BY THE ENGINEER. CONCRETE - MINIMUM 28 DAY COMPRESSIVE STRENGTH F'c = 2,000 psi, 4 SACK MIX FOR FOOTINGS., CAST IN PLACE CONCRETE CONSTRUCTION SHALL CONFORM TO ACI 318-99. WOOD - STRUCTURAL LUMBER SHALL CONFORM TO DF-L #2 OR BETTER OR HEM -FIR #2 OR BETTER BY WWPA GRADING RULES. MAXIMUM MOISTURE CONTENT SHALL BE 19% BY WEIGHT. NAILING SHALL CONFORM TO TABLE 2304.9.1 FASTENING SCHEDULE & OTHER APPROPRIATE SECTIONS OF CHAPTER 23 OF IBC 2003. ALL NAILS INTO PRESERVATIVELY TREATED WOOD SHALL BE HOT -DIPPED ZINC COATED GALVANIZED STEEL, SILICONE BRONZE, COPPER OR STAINLESS STEEL. TREATED WOOD SHALL CONFORM TO THE REQUIREMENTS OF AWPA STANDARDS C-16, C-22, C-23, C-24 & C28. POSTS FOR BUILDINGS SHALL BE AS NOTED ON THE PLANS. ALL POST MATERIALS SHALL BE HEM -FIR #2 OR BETTER, FULL DIMENSION AND GRADED BY WWPA GRADING RULES. HARDWARE SHALL BE SIMPSON OR APPROVED EQUAL. ALL BOLTS SHALL CONFORM TO ASTM A307. METAL PANELS MAY BE DELTA RIB STYLE, GALVANIZED OR PAINTED, 29 GAUGE THICKNESS, ASTM A653 STRUCTURAL QUALITY (SQ), Fy = 80.0 ksi. ROOF PANELS SHALL BE FASTENED TO PURLINS WITH PLATED, GASKETED 1 1/2" LONG METAL TO WOOD FASTENERS. WALL PANELS SHALL BE FASTENED TO GIRTS WITH PLATED, GASKETED 1" OR LONGER METAL TO WOOD FASTENERS. PANELS SHALL BE INSTALLED AND FASTENED ACCORDING TO THE MANUFACTURER'S RECOMMENDATIONS. SOIL COMPACTION - ALL BACKFILLED SOIL BENEATH FOOTINGS SHALL BE COMPACTED WITH A VIBRATORY COMPACTOR TO 95% OF THE PROCTOR DENSITY AS DETERMINED BY ASTM A1557, METHOD D. N.T.S. BUILDING • • 445 • m , rirt �a� PURLIN C❑NNECTION METHOD PURLINS WILL BE HUNG FROM LEAN TO RAFTERS WITH STANDARD SIMPSON JOIST HANGERS OR EQUAL. NOTE: PURLINS TO BE SPACED 0 16" O.C. UPPER HALF OF LEAN—TO SPAN TO RESIST SNOW DRIFT LOAD LEAN-TO RAFTER RAFTER SECTION CHART SPAN BAY SPACE LIVE LOAD PSF RAFTER SECTION SIZE OR COMBINATION ENDWALL RAFTER SECTION SIZE OR COMBINATION 8' 0' 8' 0" 30 2 - 2' X 8' 2" X 8" 8'0"10'0' 30 2-2'X8' 2"X8" 8'0',12'0' 30 2-2'X10" 2'X10' 8'0" 8' 0" 40 2-2'X8" 2"X8' 8' 0' 10' 0' 40 2 - 2" X 10" 2' X 10' • 8' 0' 1P' 0' 40 2 - 2' X 10' 2' X 10' 10'0" 8' 0" 30 2-2"X10" 2'X10' 10' 0' 10' 0' 30 2 - 2" X 10" 2" X 10' 10'0'JP'0" 30 2-2'X12' 2"X12' 10' 0" 8' 0" 40 2-2'X10' 2'X10' 10' 0" 10' 0' 40 2 - 2' X 12' 2' X 12' 10'0"1?'0' 40 2 - 2' X 8" & 2 - 2" X 6" BOX 2"X12"&2'X8" 1?'0'8'0" 30 2-2"X12' 2'X12" 1 P' 01 10' 0' 30 2 - 2" X 8" & 2 - 2' X 6" BOX 2' X 12" & 2" X 8' 1?'0'12'0" 30 2 - 2' X 10' & 2 - 2" X 6' BOX 2'X12'&2"X8" 1P' 0' 8' 0" 40 2 - 2' X 8" & 2 - 2' X 6" BOX 2' X 12' & 2' X 8' 1P'0'10'0' 40 2 - 2" X 10' & 2 - 2" X 6' BOX 2'X12'&2'X8' 1 ?' 0' 1 P' 01 40 2 - 2' X 10' & 2 - 2' X 6' BOX 2 - 2' X 12 " 14'0'8'0' 30 2 - 2" X 10' & 2 - 2" X 6' BOX 2' X 12' & 2" X 10" 14'0'10'0' 30 2-2'X10'&2-2"X6'BOX 2' X 12" & 2" X 10' 14'0',1P'0" 30 2-2"X12'&2-2"X6'BOX 2-2'X12' 14'0"8'0" 40 2 - 2' X 10' & 2 - 2' X 6' BOX 2-2'X12' 14'0"10'0' 40 2 - 2" X 12" & 2 - 2" X 6" BOX 2 - 2' X 12' DF-L #1 14'0'12' 0' 40 2 - 2' X 12' & 2 - 2' X 6' BOX DF-L #1 2 - 2' X 12" DF-L #1 16' 0' 8' 0" 30 2 - 2" X 12" DF-L S, STRUCT, 2" X 12" DF-L S. STRUCT, 16'0'10'0' 30 2 - 2' X 12' & 2 - 2" X 6" BOX 2-2'X12' 16' 0' 1?' 0' 30 2 - 2' X 12' & 2 - 2' X 6' BOX DF-L #1 2 - 2' X 12' DF-L S,S, 16'0"8'0" 40 2 - 2' X 12' & 2 - 2" X 6" BOX 2 - 2' X 12" DF-L #1 16'0'10' 0' 40 2-2'X12'&2-2'X6'BOX DF-LS.S2 - 2' X 12' DF-L S,S. 16' 0" 1?' 0" 40 4 - 2' X 12' & 2 - 2' X 6' BOX DF-L S,S 2 - 2" X 12' DF-L S,S. a. 4 : • • .`5 NOTES FOR LEAN TO CONNECTION DETAIL 0 MANUFACTURED TRUSS NOTCH POSTS 1-1/2' EACH SIDE TO PROVIDE TRUSS SEAT. 0 TRUSS SUPPORT POST, SEE POST/FOOTING SCHEDULE, S3 3/4' DIA. MACHINE BOLT - NOT REQ'D ON ENDWALLS 0 2' X 6' X 24' DF-L CONNECTION BLOCK. PROVIDE BLOCK EACH SIDE OF POST, 0 TYP, PURLIN, SEE CHART AT LEFT FOR SIZES, 0 2' X 6' OR 2' X 8' EAVE GIRT 0 2' X 6' DF-L GIRTS @ 24" O,C,. TYPICAL 8', 10' OR 12' BAYS 0 6' X 6' FULL SIZE LEAN TO POST S9 16d NAILS 10 LEAN-TO RAFTERS - SEE CHART & SECTION A -A 1A0 cl ; LEAN-TO ADDITION TO POST FRAME BUILDING STEP DOWN LEAN-TO ROOF N.T.S. FOOTING DETAIL N.T.S. NOTES FOR F❑❑TING DETAIL TREATED POSTS AS SIZED PER SCHEDULE VIBRATE OR ROD CONCRETE TO ❑BTAIN FULL BEARING UNDISTURBED S❑IL LU W CZ LLI 0 VERT. MEMBER VERT. MEMBER 1- 0 W 16d NAIL @ 10' O,C, 2' X 6" VERT. MEMBER 8 1/2' J SIMPSON J❑IST HANGER 2'X6'❑R2'X8'PURLIN 2' X 8', 2" X 10' OR 2' X 12' VERTICAL MEMBERS - SEE CHART SECTION A - A STANDARD RAFTER DETAILS 2' X 6" 8 1/2' J SIMPS❑N J❑IST HANGER 2' X 6' OR 2' X 8' PURLIN 16d NAIL @ 10' O.C. 2" X 8', 2' X 10' OR 2' X 12' VERTICAL MEMBERS - SEE CHART SECTION A - A BOX BEAM DETAILS 2' X LAMINATED TO ENDWALL RAFTER WHERE REQ'D - SEE CHART 2' X 8', 2' X 10" ❑ R 2' X 12" ENDWALL RAFTER - SEE CHART SECTION A - A STANDARD ENDWALL RAFTER DETAILS SIMPS❑N J❑IST HANGER, 2' X 6' BL❑CKIN T4 i a, 2' X 6' OR 2' X 8' PURLIN '•'t 16d NAIL @ 6' O.C. TOP & BOTTOM 2 2" X 10' OR 2" X 12' VERTICAL MEMBERS - SEE CHART - 2" X __ DETAILS EXPIRES 12/29/07 WAMBEKE ENGINEERING Daniel Wambeke, P. E. SpCourt Spoo kann e,, VWAA 99223 Telephone' 509-443-6186 Fax' 509-448-6582 a -Mall dwambekeemsn.cor LEAN-TO ADDITIONS TO POST FRAME BUILDINGS SPANS 8'-0" THROUGH 16'-0" 30 PSF & 40 PSF LIVE LOAD. IBC 2003 EXCALIBUR STEEL STRUCTURES, INC. P. 0. BOX 14991 SPOKANE, 'WASHINGTON 99214 BY DATE DRAWN CHECKED REV BY DATE DESCRIPTI❑N OF CHANGE APPROVE DLW 1-08-06 2006 DRAWING NO.' EXCALIBU R. LEAN.I BC2003-06 SCALE' N.T.S. ISHEET!' OF 1 REV. PROVIDE DIAGRA nA c A n; n EtsIpINEERINJ )A POF =1�0� Q.FAAMING \i C• . `` '.MiNG nROVIDE DIAGRAMS AND INEERING LAYOUTS FOR TRUSSES, BEAMS AND ,R SYSTEMS PRIOR TO FRAMING TIONS CITY COPY THIS BUILDING SUBJECT TO FIELD INSPECTION CORRECTIONS EgosPliziley REVIEWED FOR CODE COMPLIANCE SP0K,6,1\ VALLEY 6 !LDIN! DIVISION T'K- to 0 6