2007, 05-03 SHP-28-05 Sewer PlansGENERAL NOTES 1. ALL MATERIALS, WORKMANSHIP, AND CONSTRUCTION OF SITE IMPROVEMENTS SHALL MEET OR EXCEED SITE WORK STANDARDS AND THE STANDARDS AND SPECIFICATIONS SET FORTH IN SPOKANE COUNTY REGULATIONS AND APPLICABLE STATE AND FEDERAL REGULATIONS. WHERE THERE IS CONFLICT BETWEEN THESE PLANS AND THE SPECIFICATIONS, OR ANY APPLICABLE STANDARDS, THE HIGHER QUALITY STANDARD SHALL APPLY. ALL WORK WITHIN PUBLIC R.O.W. OR EASEMENTS SHALL BE INSPECTED AND APPROVED BY THE SPOKANE COUNTY INSPECTOR. INSPECTION SERVICES AND CONSTRUCTION CERTIFICATION TO BE PROVIDED BY DESIGNEE OF PROJECT SPONSOR/OWNER. 2. THE CONTRACTOR IS SPECIFICALLY CAUTIONED THAT THE LOCATION AND/OR ELEVATION OF EXISTING UTILMES, AS SHOWN ON THESE PLANS, IS BASED ON RECORDS OF THE VARIOUS UTILITY COMPANIES AND, WHERE POSSIBLE, MEASUREMENTS TAKEN IN THE FIELD. THE INFORMATION IS NOT TO BE RELIED UPON AS BEING EXACT OR COMPLETE. THE CONTRACTOR MUST CALL THE LOCAL UTILITY LOCATION CENTER AT LEAST 48 HOURS BEFORE ANY EXCAVATION TO REQUEST EXACT FIELD LOCATIONS OF EXISTING UTILITIES. THE CONTRACTOR SHALL VERIFY PERTINENT LOCATIONS AND ELEVATIONS, ESPECIALLY AT THE CONNECTION POINTS AND AT POTENTIAL UTILITY CONFLICTS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO RELOCATE ALL EXISTING UTILITIES THAT CONFLICT WITH THE PROPOSED IMPROVEMENTS SHOWN ON THESE PLANS. 3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL NECESSARY PERMITS FROM ALL APPLICABLE AGENCIES. THE CONTRACTOR SHALL NOTIFY THE SPOKANE COUNTY INSPECTOR AT LEAST 48 HOURS. PRIOR TO THE START OF ANY EARTH DISTURBING ACTIVITY OR CONSTRUCTION ON ANY AND ALL PUBLIC IMPROVEMENTS. 4. THE CONTRACTOR SHALL COORDINATE AND COOPERATE WITH THE SPOKANE COUNTY AND ALL UTILITY COMPANIES WITH REGARD TO RELOCATIONS OR ADJUSTMENTS OF EXISTING UTILITIES DURING CONSTRUCTION AND TO ASSURE THAT THE WORK IS ACCOMPLISHED IN A TIMELY FASHION AND WITH A MINIMUM DISRUPTION OF SERVICE. THE CONTRACTOR SHALL BE RESPONSIBLE FOR CONTACTING ALL PARTIES AFFECTED BY ANY DISRUPTION OF ANY UTILITY SERVICE. 5. THE CONTRACTOR SHALL HAVE ONE (1) SIGNED COPY OF THE APPROVED PLANS, ONE (1) COPY OF THE APPROPRIATE STANDARDS AND SPECIFICATIONS, AND A COPY OF ANY PERMITS AND EXTENSION AGREEMENTS NEEDED FOR THE JOB ON -SITE AT ALL TIMES. 6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL ASPECTS OF SAFETY INCLUDING, BUT NOT LIMITED TO, EXCAVATION, TRENCHING, SHORING, TRAFFIC CONTROL AND SECURITY. 7. IF, DURING THE CONSTRUCTION PROCESS, CONDITIONS ARE ENCOUNTERED BY THE CONTRACTOR, HIS SUBCONTRACTORS, OR OTHER AFFECTED PARTIES, WHICH COULD INDICATE A SITUATION THAT IS NOT IDENTIFIED IN THE PLANS OR SPECIFICATIONS, THE CONTRACTOR SHALL CONTACT THE ENGINEER IMMEDIATELY. 8. ALL REFERENCES TO ANY PUBLISHED STANDARDS SHALL REFER TO THE LATEST REVISION OF SAID STANDARD, UNLESS SPECIFICALLY STATED OTHERWISE. 9. FOR WORK AFFECTING PUBLIC ROADWAYS OR IF REQUIRED BY SPOKANE couNr( THE CONTRACTOR SHALL SUBMIT A TRAFFIC CONTROL AND PHASING PLAN, IN ACCORDANCE WITH M.U.T.C.D. FOR APPROVAL PRIOR TO ANY CONSTRUCTION ACTIVITIES WITHIN OR AFFECTING THE RIGHT-OF-WAY, THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ANY AND ALL TRAFFIC CONTROL DEVICES AS MAY BE REQUIRED BY SAID PLANS. PRIOR TO INSTALLATION AND PRECONSTRUCTION CONFERENCE SHALL BE HELD WITH SPOKANE COUNTY. 10. THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL LABOR AND MATERIALS NECESSARY FOR THE COMPLETION OF THE INTENDED IMPROVEMENTS SHOWN ON THESE DRAWINGS OR DESIGNATED TO BE PROVIDED, INSTALLED, CONSTRUCTED, REMOVED OR RELOCATED UNLESS SPECIFICALLY NOTED OTHERWISE. 11. PER AGENCY STANDARDS THE CONTRACTOR SHALL BE RESPONSIBLE FOR KEEPING ROADWAYS FREE AND CLEAR OF ALL CONSTRUCTION DEBRIS AND DIRT TRACKED FROM THE SITE. 12. THE, CONTRACTOR SHALL BE RESPONSIBLE FOR RECORDING RECORD INFORMATION ON A SET OF RECORD DRAWINGS KEPT AT THE CONSTRUCTION SITE AND AVAILABLE TO THE SPOKANE COUNTY INSPECTOR AT ALL TIMES. 13. DIMENSIONS FOR LAYOUT AND CONSTRUCTION ARE NOT TO BE SCALED FROM ANY DRAWING. FOR ADDITIONAL INFORMATION CONTACT THE ENGINEER FOR CLARIFICATION AND NOTE ON THE RECORD DRAWINGS. 14. ALL EROSION AND SEDIMENT CONTROL (E.S.C.) MEASURES SHALL BE INSTALLED AT THE. LIMITS. OF CONSTRUCTION PRIOR TO GROUND -DISTURBING ACTIVITY. ALL E.S.C. MEASURES SHALL BE MAINTAINED IN GOOD REPAIR BY THE CONTRACTOR UNTIL SUCH 11ME AS THE ENTIRE DISTURBED AREAS ARE STABILIZED WITH HARD SURFACE OR LANDSCAPING. 15. THE CONTRACTOR SHALL SEQUENCE INSTALLATION OF UTILITIES IN SUCH A MANNER AS TO MINIMIZE POTENTIAL UTILITY CONFLICTS. IN GENERAL, STORM SEWER AND SANITARY SEWER SHOULD BE CONSTRUCTED PRIOR TO INSTALLATION OF WATER LINES AND DRY UTILITIES. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO COORDINATE ALL UTILITY RELOCATIONS CONSISTENT WITH THE CONTRACTORS SCHEDULE FOR THIS PROJECT, WHETHER SHOWN OR NOT SHOWN, AS IT RELATES TO THE CONSTRUCTION ACTIVITIES CONTEMPLATED IN THESE PLANS. 16. ALL WORK WITHIN THE PUBLIC RIGHT-OF-WAY IS SUBJECT TO THE JURISDICTION OF THE SPOKANE COUNTY ENGINEERING DEPARTMENT STANDARD DETAILS AND SPECIFICATIONS. 17. ALL CONSTRUCTION OPERATIONS , INCLUDING THE WARMING UP, REPAIR, ARRIVAL, DEPARTURE OR RUNNING OF TRUCKS, EARTH MOVING EQUIPMENT, CONSTRUCTION EQUIPMENT AND ANY OTHER ASSOCIATED EQUIPMENT SHALL GENERALLY BE LIMITED TO THE 11ME PERIOD APPROVED BY SPOKANE COUNTY. 18. BASED ON A REQUIREMENT FROM THE SPOKANE COUNTY THE ENGINEER OR HIS DESIGNEE SHALL PERFORM MATERIALS TESTING AND QUALITY CONTROL ON THE PROJECT AND SHALL SUBMIT COPIES OF DAILY REPORTS, TEST REPORTS, PROJECT CERTIFICATION AND RECORD DRAWINGS TO THE SPOKANE COUNTY ENGINEER. 19. NO REVISIONS SHALL BE MADE TO THESE PLANS WITHOUT THE APPROVAL BY THE SPOKANE COUNTY ENGINEER AND NOTIFICATION OF THE ENGINEER OF RECORD. 20. ONSITE GRADING SHALL BE IN ACCORDANCE WITH THE APPROVED GRADING PLAN AND E.S.C. PLAN. ANY IMPORT OR EXPORT OF MATERIAL SHALL BE FROM A PREAPPROVED SOURCE/DESTINATION AND COORDINATED WITH THE SPOKANE COUNTY DEPARTMENT OF BUILDING AND PLANNING AT 509-477-3675. GRADING ON THIS SITE OR ANY OTHER SITE MUST COMPLY WITH ALL DEVELOPMENT REGULATIONS INCLUDING, BUT NOT LIMITED TO, GRADING PERMITS, S.E.P.A. REVIEW, TIMBER HARVEST PERMITS, CRITICAL AREAS, FLOODPLAINS, DESIGNATED DRAINAGEWAYS, ETC. SEWER SPOKANE COUNTY UTILITIES 1026 WEST BROADWAY AVENUE SPOKANE, WASHINGTON 99260 PHONE: 509-477-3604 FAX: 509-477-4715 CONTACT: BILLY URHAUSEN WATER PURVEYOR MODERN ELECTRIC WATER CO. NORTH 904 PINES ROAD SPOKANE VALLEY, WA 99206 PHONE: 509-928-4540 FAX: 509-755-9000 CONTACT: DAVE JOHNSON SPOKANE REGIONAL HEALTH 11:01 W. COLLEGE AVENUE SPOKANE, WA 99260 PHONE: 509-324-1560 FAX: 509-324-3603 CONTACT: DON COPLEY KAAtiei. ATIONS SHOWN ARE BASED ON C.B.M. "HV5-26-3," A "+" ON THE NORTH FLANGE BOLT OF A FIRE HYDRANT, ON THE SOUTH SIDE OF 6TH AVENUE, +/- 200EAST OF PERRINE, PER ULID-952. BENCH LEVEL NOTES, DATED 10/26/94. ELEV = 2007.03 DISTRICT ENGINEER SIMPSON ENGINEERS 909 NORTH ARGONNE ROAD SPOKANE VALLEY, WA 99206 PHONE: 509-926-1322 PHONE: 509-926-1323 CONTACT: KEVIN McMULKIN, P.E. STREETS CITY OF SPOKANE VALLEY 11707 E. SPRAGUE AVENUE SPOKANE VALLEY, WA 99206 PHONE: 509-688-0228 PHONE: 509-921-1008 CONTACT: HENRY M. ALLAN, P.E. SURVEYOR WHIPPLE CONSULTING ENGINEERS 2528 NORTH SULLIVAN ROAD SPOKANE VALLEY, WA 99216 PHONE: 509-893-2617 FAX: 509-926-0227 CONTACT: TERRY IRWIN, P.L.S. POWER MODERN ELECTRIC WATER CO. NORTH 904 PINES ROAD SPOKANE VALLEY, WA 99206 PHONE: 509-928-4540 FAX: 509-755-9000 CONTACT: JOHN McFEELY TELEPHONE QWEST 904 NORTH COLUMBUS SPOKANE, WASHINGTON, 99202 PHONE: 509-455-2580 FAX: 509-455-2104 CONTACT: DAVE CLARK ENGINEER WHIPPLE CONSULTING ENGINEERS 2528 NORTH SULLIVAN ROAD SPOKANE VALLEY, WA 99216 PHONE: 509-893-2617 FAX: 509-926-0227 CONTACT: TODD R. WHIPPLE, P.E. LOPER'S APPROVAL •••=11•111.111 .1M111.111•1 1=1•111111111111. T SEWER PLANS SPOKANE COUNTY, WASHINGTON SPOKANE VALLEY NE 1/4 SECTION 21, To 25 No, R. 44 Ea, Walvis G - . ............................ _ ... - .1•11e11. Memo anee./Meo ,&/,./09simmimp 1 I 10.67' SITE PLAN SCALE: 1” = 30' FIRE. DEPARTMENT FIRE DISTRICT NO. 1 EAST 10319 SPRAGUE AVENUE SPOKANE VALLEY, WA 99206 PHONE: 509-928-1700 FAX: 509-892-4125 CONTACT: PAUL CHASE DP EXISTING HOUSE E. 12104 6TH. AVE. ,-" 115.06' CABLE SOLID WASTE COMCAST BROADBAND 1717 EAST BUCKEYE SPOKANE, WASHINGTON, 99207 PHONE: 509 101 1031 •75S-4/117 effEstetelvir-e364 CONTACT: BRYAN RICHARDSON INSPECTION ALL WEST 12928 EAST INDIANA AVENUE SPOKANE VALLEY, WA 99216 PHONE: 509-534-4411 FAX: 509-534-9326 CONTACT: PAUL T. NELSON, P.E. WASTE MANAGEMENT PHONE: 509-466-3400 OWNER RAY WILLMAN 12104 E. 6TH. AVENUE SPOKANE VALLEY, WA 99206 PHONE: 509-924-1585 CONTACT: RAY WILLMAN X 260.36' MH 3MA riTH. AVENUE ------- - --- Gulp 011.101•• ••••••••• allimoner -G 1 122.00= - ABBREVIATIONS ACT. LEN. .... ACT LENGTH GB BCR BEGINNING OF CURVE FT. / FT. BDRY. BOUNDARY HYD. CO. SEWER CLEANOUT I.E. CSTC CRUSHED SURFACE LN. TOP COURSE LT. CT. COURT MH DIA. ................DIAMETER ECR END OF CURB EXIST. EXISTING G GRADE N8b*49'56”E GRADE BREAK FEET PER FOOT HYDRANT INVERT ELEVATION LANE LEFT MANHOLE MCR MID POINT OF CURVE STA. PC POINT OF CURVE STA. LEN PET. PETROLEUM TG PI POINT OF INTERSECTION TC -0 0 Co 0 0 001 cJ -G- .110111•1111 MENEM 1•1111 say4.4'.'"45150ST MH 4M 121.6 6 O.' ....._ 21 54 I 44 /vars.: 7/4 PvTEsGcriem/ - c7F 407-1)- WAN /714-s CHAA1547, SE "E STREg'T PLAA/S. 0" (1/ PRC POINT OF REVERSE CURVE PT . POINT OF TANGENCY RIM *EL. RIM ELEVATION RD ROAD RT. RIGHT SI STREET INTERSECTION SS SANITARY SEWER STATION STATION LENGTH TOP OF GRATE TOP OF CURB THE DESIGN IMPROVEMENTS SHOWN IN THIS SET OF PLANS AND CALCULATIONS CONFORM TO APPLICABLE EDITIONS OF THE SPOKANE COUNTY STANDARDS FOR ROAD AND SEWER CONSTRUCTION AND THE SPOKANE COUNTY GUIDELINES FOR STORMWATER MANAGEMENT AS MODIFIED BY THE CITY OF SPOKANE VALLEY. ALL DESIGN DEVIATIONS HAVE BEEN APPROVED BY THE CITY OF SPOKANE VALLEY ENGINEER. I APPROVE THESE PLANS FOR CONSTRUCTION. SCALE: RLM SUBMITTAL FOR APPROVAL HORIZONTAL: AS SHOWN 1 0/04 •RLM' ORIGINAL PLAN PFIEPARATION NO: DATE BY REVISIONS VERTICAL: N.A. PROJ #: 2004.82 DATE: 01 /15/07 DRAWN: RLM APPROVED: TRW I:I 5 EXISTING 0-- V FH WS 0- 9Ea\ALL kBLOWOFF )AVRS° GM 0 CB MH VICINITY MAP 11111111111m T BT OP -0- PP A BP TP 0 TR TV GA E- P V OLP OP P LEGEND GENERAL ROADWAY CENTER LINE RIGHT OF WAY LINE PROPERTY LINE EASEMENT LINE FENCE CURB PAVEMENT GRAVEL CONCRETE BUILDINGS & STRUCTURES MONUMENT SANITARY SEWER SANITARY SEWER MANHOLE CLEANOUT SEWER SERVICE WATER WATER LINE VALVE FIRE HYDRANT SERVICE METER BLOWOFF AIR VACUUM RELIEF STATION STORM DRAINAGE DRAINAGE LINE MANHOLE DRYWELL CATCH BASIN DITCH NATURAL GAS GAS LINE VALVE METER TELEPHONE POWER BURIED TELEPHONE POWER OR TELEPHONE POLE BURIED POWER TRANSFORMER PAD TELEPHONE RISER TELEPHONE VAULT OVERHEAD POWER GUY ANCHOR POWER VAULT LIGHT POLE INDEX TO PLAN SHEETS SHEET NO. 1 COVER AND NOTES SHEET NO. 2 DEMOLITION PLAN SHEET NO. 3 NOTES AND DETAILS SHEET NO. 4 SIXTH AVENUE SHEET NO. 5 WHIPPLE LANE WHIPPLE CONSULTING ENGINEERS CIVIL AND TRANSPORTATION ENGINEERING 2528 NORTH SULLIVAN ROAD SPOKANE VALLEY, WA 99216 PH: 509-893-2617 FAX: 509-926-0227 456-8000 CALL TWO BUSINESS DAYS BEFORE YOU DIG N W PROPOSED ) ) • o(FH WS is WM RI nwnFF IAVRS DW CB • • , OMH GM T BT P- Br in TR TV OP OP GA PV LP( TP P INSPECTIONS & PERMITS REQUIRED PER SPOKANE COUNTY STANDARD PLANS AND SPECIFICATIONS ACCEPTED FOR CON TRUCTjeQN BY D -.21t -07 FILE iiREZ-21.05 SPOKANE COUNTY UTILITIES SEWER PLANS SHORT PLAT-2 COVER SHEET SPOKANE COUNTY, WASHINGTON SPOKANE VALLEY EXPIRES 9/24/1010 1 SHEET 1 OF 5 JOB NUMBER 2004-82 G 6TH. AVENUE G _ __ --- _ C __ FLAN SCALE: = 0' X owl*, Anammo. . 12" — —1-4- EXISTING HOUSE E. 12104 6TH. AVE. 10.67' -- b . .. c3 so-- .. • •CNI ../ 0) , ,, oi (7) STUM X 6 L_ X 260.36' LA2 10 )6- - - - - - - - - - - - - - I — WHIPPLE LANE FIAMMERHEAia X ' N89'47153”E rm.._ L\C)• . _N. 5 / / 2 3 4 __X NE 1/4 SECTIC3N 219 T. 25 N. R. 44 E. W M. / / C/rIAP o N• ' '00 tX' c\I 0 0 XZ G Sla 1 DEM LITI 0 N N OTES 0 TREE TO BE REMOVED. EXISTING WATER METER TO RELOCATED PER MODERN AtUgggitj:NCR61169-fAN4D7R'DS. EXISTING POWER AND LIGHT POLE TO BE RELOCATED BY MODERN VfM411=i6"4171-D5ORIY DEVELOPER. EXISTING- FENCE TO BE REMOVED AND / OR REPLACED AS AGREED ON WITH OWNER. EXISTING HOSE BIBB TO BE ABANDONED PER 410035e144-10A14-eer—STA-413-ARDSW EIZ EXISTING FENCE TO BE REMOVED. EXISTING SHED TO BE REMOVED OR RELOCATED AS AGREED UPON WITH OWNER. GRAPHIC SCALE 30 0 15 30 NM IN 11111 ( IN FEET ) 1 inch = 30 ft. 60 -&rIPLAN,D. 88 ELEVATIONS SHOWN ARE BASED ON C.B.M. "HV5-26-3," A "+" ON THE NORTH FLANGE BOLT OF A FIRE HYDRANT, ON THE SOUTH SIDE OF 6TH AVENUE, +/- 200' EAST OF PERRINE, PER ULID-952 BENCH LEVEL NOTES, DATED 10/26/94. ELEV = 2007.03 2/1/07 D VELOPER'S APPROVAL DATE SCALE: NO. 10/04 DATE RLM RLM BY SUBMITTAL FOR APPROVAL ORIGINAL pLAN 'PREPARATION REVISIONS HORIZONTAL: AS SHOWN VERTICAL: NA. PROJ #: 2004.52 DATE: 01/15/07 DRAWN: RLM APPROVED: TRW WHIPPLE CONSULTING ENGINEERS CIVIL AND TRANSPORTATION ENGINEERING 2528 NORTH SULLIVAN ROAD SPOKANE VALLEY, WA 99216 PH: 509-893-2617 FAX: 509-926-0227 FILE #REZ-21 05 INSPECTIONS & PERMITS REQUIRED PER SPOKANE COUNTY STANDARD PLANS AND SPECIFICATIONS SEWER PLANS SHORT PLAT-28-05 DEMOLITION PLAN SPOKANE VALLEY SPOKANE COUNTY5WASHINGTON CALL TWO BUSINESS DAYS BEFORE YOU DIG 4 ss704/NSp44 ATLE%cf: /F., 2562 441: e lExpiREs 9/24/ I SHEET 2 OF 5 JOB NUMBER • 2004-82 IN -LINE MANHOLE NOTES: A. ALL MATERIALS FOR INSTALLATION SHALL BE ON SITE PRIOR TO CONSTRUCTION. B. ALL PIPE SHALL BE SAWCUT. C. THE CONTRACTOR SHALL PROHIBIT ANY DELITRIOUS MATERIAL FROM ENTERING SEWER LINE DURING CONSTRUCTION OF NEW MANHOLE. D. COUNTY INSPECTOR SHALL BE ONSITE AT TIME OF MANHOLE CONSTRUCTION. CALL 477-3604 24 HRS. IN ADVANCE TO SCHEDULE INSPECTION, ASK FOR BILLY OR LOUIS. CONTRACTOR WILL BE BILLED $100.00 FOR TAP FEE. E. CONTRACTOR MAY PLUG THE EXISTING 8" LINE AT THE NEXT EXISTING UPSTREAM MANHOLE WHILE THE NEW MANHOLE IS [NISTA! 1 FD BUT MUST MONITOR UPSTREAM MANHOLES AND HAVE SUFFICIENT EQUIPMENT AVAILABLE TO AVOID A BACKUP OF SEWAGE INTO HOMES. 6" RADIUS UPSTREAM SWEEP HAND SHAPED MORTAR FILLET TO PROVIDE POSITIVE DOWNSTREAM SWEEP NE 1/4 SECTIC3N 219 T. 25 No9 R 4 4 Eo9 WoMo NOTE: HAVE NEW MANHOLE CAST AT .0039 ON THROUGH CHANNEL EXTEND NEW 8" PIPE 18" BEYOND MANHOLE BARREL r ) EXISTING I (, EXII1 8" a" SP EXTEND NEW 8" PIPE 18" BEYOND MANHOLE BARREL MANHOLE TYPE I-48S WITH PRECAST CHANNELS CHANNEL SLOPE=0.0030 FT./FT. IN -LINE MANHOLE INSTALLATION DETAIL NOT TO SCALE 1/8" LRAISED -1/21 WIDE BORDER ven 27/8" 1/2 3/4" SQUARES SPACED 3/4" HEIGHT 1/8" 1 0" 1 I. 9n 11 -> I, I 183 I I CAST IRON RING SECTION A -A PIPE MATERIAL AS SPECIFIED 45BEND OR WYE FINISHED GRADE MIN. 12" DIA. ADJUST. SECTION 8 3/4" 11- 7:4" -11 CAST IRON COVER CAST RING & COVER FIBER JOINT PACKING OR EQUAL. 45' BEND 2' -0" A SEWER CLEAN -OUT L-1 1/4" 'WW 5 GRIPPER PLUG MIN. )CONCRETE CL 3000 (lift) POURED IN PLACE. UNDISTURBED SOIL BASE CLEAN 0 UT SPOKANE COUNTY STANDARD PLAN U-13 NOT TO SCALE INSTALL 8" DIA PVC REPAIR COUPLING 2-REQUIRED) CONSTRUCT I.E. OF NEW 8" PVC SEWER TO BE A MINIMUM OF 0.10' HIGHER THAN I.E. OF *MAIN LINE CHANNEL EXISTING GROUND 6" DEPTH (MAX.) 2"x 4" BOARD 32" LONG 18" LENGTH OF 1/2" REBAR SECURED TO TOP PORTION. M5' BEND MINIMUM 36" BETWEEN FITTINGS END OF STUB, INVERT ELEVATION AT THIS POINT AS SHOWN ON CONSTRUCTION PLANS PAY UMIT FOR "SIDE SEWER RISER" PVC SIDE SERVICE SEWER CONNECTION PIPE (TYP.) 45' BEND SERVICE TEE TYPE "A" NOTES PAY UMITS FOR "SIDE SEWER PIPE" SEE NOTE 2 SIDEWAU< GLUE ON CAP 45' BEND MIN. SLOPE (UNLESS OTHERWISE NOTED) 45' BEND 22 1/2' BEND SERVICE TEE TYPE "B" vpisiso TYPE "C" 1. INSTALL PIPE ZONE MATERIAL (BEDDING) PER SPECIFICATIONS. 2. THE SIDE SEWER PIPE SHALL EXTEND TO THE POINT SHOWN ON THE PLANS. HE ENGINEER MAY FURTHER EXTEND THE SIDE SEWER PIPE TO MAINTAIN A 1:1 SLOPE FROM EXISTING OR PLANNED EDGE OF ASPHALT OR CONCRETE IMPROVEMENTS. 3. ALL SIDE SERVICES TO BE INSTALLED AT A MINIMUM DEPTH OF 8' WITHIN THE RIGHT OF WAY, UNLESS APPROVED BY THE SEWER DESIGN MANAGER. 4. THE RECORD DRAWINGS FOR EACH INDIVIDUAL STUB SHALL INCLUDE TWO (2) HORIZONTAL TIES TO THE TOP OF THE RISER. IN ADDITION, THE SEWER MAINUNE STATION AND 90' OFFSET DISTANCE TO THE RISER PIPE SHALL BE PROVIDED. THE DEPTH AND INVERT ELEVATION REQUIRED ON THE RECORD DRAWING (SPOKANE COUNTY STD. SHEET U-16) SHALL REt-ut TO 'THE PIPE INVERT AT THE BOTTOM OF THE SIDE SEWER RISER. 5. ALL CONNECTIONS SHALL BE TYPE "A" UNLESS OTHERWISE NOTED. 6. SIDE SEWER RISER IS OPTIONAL INSIDE NEW DEVELOPMENTS. IF RISER IS NOT A INSTALLED, EXTEND 2"X 4" MARKER TO STUB INVERT. 7. SERVICE TEE SHALL MEET ASTM. 03034, SDR 26. TYPICAL SEWER SERVICE DETAIL. NOT TO SCALE ROADWAY SEE NOTE 3 SERVICE TEE / TEE SEWER GENERAL NOTES SEWER CONSTRUCTION, INSPECTIONS, RECORD DRAWINGS, AND ENGINEER'S STATEMENTS SHALL CONFORM TO THE REQUIREMENTS SET FORTH IN THE SPOKANE COUNTY PROJECT CONSTRUCTION CERTIFICATION PROCEDURES FOR ROAD, DRAINAGE AND SEWER PROJECTS DATED APRIL, 2002. THE DEVELOPER'S CONSTRUCTION ENGINEER SHALL SUBMIT A LETTER OF INTENT TO PROVIDE CONSTRUCTION INSPECTION AND RECORD DRAWING SERVICES PRIOR TO THE COUNTYS ACCEPTANCE OF THESE PLANS FOR CONSTRUCTION. 1. GENERAL: ALL SEWER LINE CONSTRUCTION METHODS AND MATERIALS SHALL BE IN ACCORDANCE WITH THE STANDARD SPECIFICATIONS FOR ROAD, BRIDGE, AND MUNICIPAL CONSTRUCTION AS JOINTLY PROMULGATED BY THE WASHINGTON STATE DEPARTMENT OF TRANSPORTATION AND THE WASHINGTON STATE CHAPTER OF THE AMERICAN PUBLIC WORKS ASSOCIATION, CURRENT EDITION, AS ADOPTED AND REVISED BY THE SPOKANE COUNTY UTILITIES DEPARTMENT. THESE PLANS ARE SCHEMATIC AND ARE NOT INTENDED TO DEPICT ALL DETAILS OF THE WORK REQUIRED. THE CONTRACTOR SHALL BE RESPONSIBLE TO FAMILIARIZE HIMSELF WITH ACTUAL SITE CONDITIONS AND FACTORS AFFECTING THE WORK. THE CONTRACTOR SHALL BE RESPONSIBLE TO COORDINATE WITH SPOKANE COUNTY TO DEVELOP A TRAFFIC CONTROL PLAN AND INSPECTION REQUIREMENTS. THE CONTRACTOR SHALL BE RESPONSIBLE TO OBTAIN ALL REQUIRED PERMITS. PAVEMENT PATCHING REQUIREMENTS SHALL BE AS DETERMINED BY THE SPOKANE COUNTY ROAD DEPARTMENT. IN ADDITION, THE CONTRACTOR SHALL ADHERE TO ALL SPOKANE COUNTY STANDARDS FOR ROAD AND SEWER CONSTRUCTION. THE CONRACTOR SHALL PROVIDE ALL MATERIALS, LABOR, AND EQUIPMENT TO CONSTRUCT AND INSTALL TO PROPER WORKING ORDER, AS DETAILED OR CALLED OUT IN THESE PLANS AND SPECIFICATIONS. 2. PIPE: ALL SEWER PIPE SHALL BE PVC IN ACCORDANCE WITH A.S.T.M. D 3034, SDR 35. ALL SEWER SERVICE TEES SHALL BE A.S.T.M. D 3034 SDR 26, TYPICAL. 3. TRENCH EXCAVATION AND BACKFILL: ALL TRENCH EXCAVATION AND BACKFILL SHALL CONFORM TO W.S.D.O.T. SECTION 7-08.3(1)A. ALL BEDDING SHALL CONSIST OF APPROVED BEDDING MATERIAL PLACED AROUND THE PIPE AND BACKFILLED AS PER W.S.D.O.T. SECTION 7-08.3(1)C. BEDDING SHALL MEET W.S.D.O.T. 9-03.12(3) SPECIFICATIONS EXCEPT PERCENT PASSING 200 SIEVE IS CHANGED TO 10% MAXIMUM. COMPACTION OF BACKFILL IN ROADWAY SHALL BE PERFORMED TO MEET SPOKANE COUNTY ENGINEER'S REQUIREMENTS. TESTING COLLECTOR SEWERS AND SIDE SEWERS SHALL BE DONE IN ACCORDANCE WITH SPOKANE COUNTY UTILITIES DEPARTMENT. 4. MANHOLES: SHALL BE IN ACCORDANCE WITH SANITARY SEWER MANHOLE DETAILS AS ADOPTED BY SPOKANE COUNTY UTILITIES DEPARTMENT. 4A. NOTE: ALL MANHOLES OUTSIDE OF PAVED PUBLIC RIGHT OF WAY SHALL HAVE LOCKABLE BOLT DOWN LIDS. 5. SIDE SEWERS: EACH SEWER SERVICE LINE SHALL BE A MINIMUM OF 10 FEET FROM SIDE LOT LINES. ALL SIDE SEWER TEES SHALL BE SDR "26" HEAVY WALL PVC. EACH SEWER SERVICE LINE AND MAINLINE STUB SHALL BE MARKED WITH A 4"x4" MARKER POST EXTENDING VERTICALLY FROM THE SEWER SERVICE OR MAINLINE STUB INVERT TO A MINIMUM OF 24" ABOVE FINISHED GRADE. EACH 4"x4" MARKER POST SHALL HAVE A 6 GAUGE GALVANIZED WIRE SECURELY ATTACHED FOR ITS ENTIRE LENGTH AND SHALL BE CLEARLY MARKED SHOWING THE 4"x4" LENGTH IN FEET AT THE EXPOSED END. 6. INSPECTION WORK: ALL SEWER CONSTRUCTION INSPECTIONS, RECORD DRAWINGS AND ENGINEERING STATEMENTS SHALL CONFORM TO THE REQUIREMENTS SET FORTH IN THE SPOKANE COUNTY PROJECT CONSTRUCTION CERTIFICATION PROCEDURES FOR ROAD, DRAINAGE AND SEWER PROJECTS DATED APRIL, 2002. PROJECT SPONSOR OR HIS ENGINEER SHALL NOTIFY THE SPOKANE COUNTY DIVISION OF UTILITIES AT LEAST 48 HOURS IN ADVANCE OF THE START OF CONSTRUCTION OF THE SEWER SYSTEM, AND THE CONTRACTOR SHALL PROVIDE A GENERALIZED CONSTRUCTION SCHEDULE FOR THE PROGRESS OF WORK. THE CONTRACTOR SHALL COORDINATE THE WORK WITH THE ENGINEER AND PROVIDE ALL MEANS NECESSARY TO ALLOW THE ENGINEER TO INSPECT AND VERIFY THE SEWER ITEMS LISTED BELOW. FOR EACH ITEM TO BE INSPECTED, THE CONTRACTOR SHALL NOTIFY THE ENGINEER AT LEAST 48 HOURS IN ADVANCE. A. CONFORMANCE OF ALL CONSTRUCTION MATERIALS WITH COUNTY STANDARDS SHALL BE VERIFIED PRIOR TO INSTALLATION. B. THE SEWER TRENCH SHALL BE INSPECTED FOR PROPER DIMENSIONS AND PIPE ZONE CLEARANCES PRIOR TO PLACEMENT OF PIPE. C. THE PLACEMENT AND COMPACTION OF THE PIPE ZONE MATERIAL AND BEDDING SHALL BE INSPECTED. D. THE PIPE JOINTS SHALL BE INSPECTED VISUALLY FOR PROPER INSERTION. E. HORIZONTAL ALIGNMENT AND GRADE OF THE PIPE SHALL BE CHECKED FOR CONFORMANCE TO THE STANDARDS PRIOR TO BACKFILLING OF THE TRENCH. F. SEWER SERVICE TEES AND STUBS SHALL BE INSPECTED FOR CORRECT INSTALLATION PRIOR TO BACKFILLING OF THE TRENCH. G. ACCURATE MEASUREMENTS SHALL BE MADE AND RECORDED TO FACILITATE THE RE-ESTABLISHMENT OF SEWER SERVICE TEE LOCATIONS AND STUB END LOCATIONS. THE PLACEMENT OF THE REQUIRED STUB MARKERS SHALL BE VERIFIED. H. MANHOLES SHALL BE INSPECTED FOR PROPER MATERIALS, LOCATION, ASSEMBLY, AND INSTALLATION. I. TRENCH BACKFILLING OPERATIONS SHALL BE OBSERVED AND COMPACTION TESTS SHALL BE PERFORMED. MINIMUM REQUIREMENTS FOR BACKFILLING SHALL BE AS SET FORTH IN THE ACCEPTED PLANS AND/OR SPECIFICATIONS FOR THE PROJECT. 1. REGARDING NOTE NO. 5: PER SPOKANE COUNTY STANDARD DETAIL, U-5 A 2 x 4 MARKER POST MAY BE SUBSTITUTED FOR THE 4 x 4 MARKER POST REFERENCED. IT IS THE CONTRACTOR'S RESPONSIBILITY TO MAINTAIN THIS POST THROUGHOUT THE COURDE OF CONSTRUCTION TO THR SATISFACTION OF THE ENGINEER. 2. SEWER STUB LOCATION AND SIZE SHALL BE COORDINATED BY ENGINEER WITH HOMEOWNER PRIOR TO CONSTRUCTION. WRITTEN CORRESPONDENCE WITH HOMEOWNER IS REQUIRED AND COPIES SHALL BE SUBMITTED TO THE COUNTY FOR THE RECORD. 3. ALL PARCELS THAT ARE ADJCENT TO THIS SEWER PROJECT AND ARE LARGE ENOUGH TO SHORT PLA I tt.D OR FURTHER DEVELOPED SHALL HAVE A MINIMUM OF A 6" SERVICE STUB ADDED FOR FUTURE DEVELOPMENT. N.A.V.D 88 ELEVATIONS SHOWN ARE BASED ON C.B.M. "HV5-26-3," A "+" ON THE NORTH FLANGE BOLT OF A FIRE HYDRANT, ON THE SOUTH SIDE OF 6TH AVENUE, +/- 200' EAST OF PERR1NE, PER UUD-952 BENCH LEVEL NOTES, DATED 10/26/94. ELEV. = 2007.03 2/037 DATE SCALE: RLM SUBMITTAL FOR APPROVAL NO. 10/04 DATE RLM RLM BY SUBMITTAL TO SPOKANE couNrir UTILITIES ORIGINAL PLAN- PREPARATION REVISIONS HORIZONTAL: AS SHOWN VERTICAL: NA. PROJ #: 2004.82 DATE: 01 /15/07 DRAWN: RLIVI APPROVED: TRW WHIPPLE CONSULTING ENGINEERS CIVIL AND TRANSPORTATION ENGINEERING 2528 NORTHSULLIVAN ROAD SPOKANE VALLEY, WA 99216 PH: 509-893-2617 FAX: 509-926-0227 UNDERGROUND SERVICE ALERT ONE -CALL NUMBER 456.8000 CALL TO BUSINESS DAYS BEFORE YOU DIG J. MANDREL TESTING, HYDROSTATIC AND/OR AIR PRESSURE TESTING, AND MANHOLE TESTING SHALL BE PERFORMED FOLLOWING COMPLETION OF TRENCH BACKFILLING OPERATIONS. THE TESTING SHALL BE OBSERVED UNTIL PASSING RESULTS ARE OBTAINED. MANHOLE TESTING SHALL BE PERFORMED ON TEN PERCENT OF THE MANHOLES IN THE PROJECT, IN ACCORDANCE WITH DEPARTMENT OF ECOLOGY'S "CRITERIA FOR SEWAGE WORKS DESIGN". K. THE SPONSORS ENGINEER SHALL SCHEDULE TELEVISION INSPECTION OF THE SEWER LINES THROUGH THE DIVISION OF UTILITIES ONCE THE OTHER TESTING HAS BEEN SATISFACTORILY COMPLETED. THE DIVISION OF UTILITIES WILL THEN PERFORM THE TELEVISION INSPECTION AND SUBMIT THE REPORT TO THE INSPECTING ENGINEER, WHO REVIEWS THE TAPES FOR DEFICIENCIES REQUIRING CORRECTION OR REPAIR. L. THE ITEMS LISTED UNDER RECORD DRAWINGS (NOTE #7) SHALL BE INCLUDED IN THE INSPECTION AND TESTING WORK. 7. RECORD DRAWINGS: REPRODUCIBLE RECORD DRAWINGS WITH "ENGINEERS STATEMENT" ARE TO BE SUBMITTED TO AND APPROVED BY THE SPOKANE COUNTY UTILITIES DEPARTMENT AT THE COMPLETION OF CONSTRUCTION. 2 HORIZONTAL AND 1 VERTICAL TIES SHALL BE SHOWN ON RECORD DRAWINGS FOR ALL SIDE SEWER SERVICES, MAIN LINE STUBS, AND CLEANOUTS. STUBS THAT ARE NOT CONSTRUCTED PERPENDICULAR TO SEWER MAIN WILL NEED A STATION AND OFFSET FROM SEWER MAIN TO END CAP SHOWN ON RECORD DRAWINGS. STATIONS SHALL BE FROM DOWNSTREAM MANHOLE AND MEASURED ON MAIN SEWER LINE. MINIMUM SEWER RECORD DRAWING REQUIREMENTS ARE AS FOLLOWS: A. PIPE SIZE AND TYPE/LENGTH AND SLOPE BETWEEN MANHOLES. B. ACTUAL RIM AND. INVERT ELEVATION AT EACH MANHOLE. C. DISTANCE FROM DOWNSTREAM MANHOLE TO SIDE SEWER SERVICE STUB ENDS. 90 TO STUB END. FROM SEWER MAIN OR BACK OF CURB (NOT PROPERTY LINES). D. ALL ANGLE POINTS OR BENDS ON SIDE SERVICE LINE SHALL BE LOCATED WITH 2 HORIZONTAL SWING TIES. STUBS NOT CONSTRUCTED PERPENDICULAR TO SEWER MAIN WILL REQUIRE A STATION ON THE SERVICE TEE ALSO SHOWN ON RECORD DRAWINGS. E. ACTUAL INVERT ELEVATION OF STUB AND CALCULATED DEPTH FROM ADJOINING CURB OR NATURAL GROUND. THE ENGINEER SHALL COMPLETE 8 1/2 x 11 COUNTY STANDARD PLAN SHEET U-16 (SIDE SERVICE CONNECTION RECORD DRAWING) FOR EACH SIDE SERVICE WITHIN PROJECT OR PLAT AND SUBMIT WITH RECORD DRAWINGS OF PLAN AND PROFILE SHEETS PRIOR TO PROJECT SIGN OFF. F. STREET WIDTH/BACK TO BACK OF CURBS/WIDTH OF RIGHT-OF-WAY. G. LOCATION OF SEWER MAIN WITHIN STREET. FORCE MAIN ANGLE POINTS SHALL BE LOCATED TWO WAYS HORIZONTALLY AND ONE WAY VERTICALLY FROM PERMANENT SURFACE FEATURES. H. STUBS NOT 10' FROM THE SIDE LOT LINES MUST BE MOVED OR A MAINTENANCE EASEMENT MUST BE PROVIDED OR A HOLD COUNTY HARMLESS AGREEMENT MUST BE PROVIDED. I. SHOW ALL SERVICED LOTS, LOT NUMBERS, BLOCK NUMBERS AND LOT LINES. J. SHOW DIMENSIONS AND INCLUDE A COPY OF THE RECORDED EASEMENT DOCUMENT FOR ALL MAINLINE SANITARY SEWER EASEMENTS (10' MINIMUM EACH SIDE OF PIPE). INCLUDE COUNTY MANHOLE NUMBERS. K. HOW SECTION, TOWNSHIP, RANGE AND QUARTER SECTION. L. RECORD DRAWINGS SHALL BE ON MYLAR AND IN INK AND MUST BE REVIEWED AND APPROVED PRIOR TO THE APPROVAL OF A PRIVATE SEWER CONNECTION OR PRIOR TO THE ACCEPTANCE OF A PUBLIC SEWER SYSTEM FOR MAINTENANCE AND OPERATION BY SPOKANE COUNTY UTILITIES DEPARTMENT. M. THE OWNER/DEVELOPER IS REQUIRED TO EMPLOY A PROFESSIONAL ENGINEER AND/OR PROFESSIONAL LAND SURVEYOR TO PROVIDE RECORD DRAWINGS TO THE COUNTY UTILITIES DEPARTMENT AT THE END OF CONSTRUCTION. 8. TESTING AND ACCEPTANCE: THE LOW PRESSURE AIR TEST METHOD SHALL BE USED. ALL LINES SHALL BE CLEANED AND TV INSPECTED PRIOR TO ACCEPTANCE BY SPOKANE COUNTY. ALL SEWER LINES SHALL BE CLEANED PRIOR TO TV INSPECTION BY JET RODDING OR BY FLUSHING. NOTE: WHEN FLUSHING IS USED BY A CONTRACTOR TO CLEAN LINES. THE ENGINEERS INSPECTION REPRESENTATIVE SHALL BE PRESENT ON -SITE TO INSURE THAT NO CONSTRUCTION MATERIAL IS FLUSHED INTO THE EXISTING COUNTY SEWER SYSTEM. 9. INSTALLATION OF SEWER SERVICE: PRIOR TO THE INSTALLATION OF SEWER SERVICES, THE CONTRACTOR SHALL COORDINATE WITH EACH RESIDENT, A MINIMUM OF 48 HOURS IN ADVANCE OF THE INSTALLATION OF THIER SERVICE. THE CONTRACTOR SHALL REMOVE AND REPLACE FENCING AND DRIVEWAYS REQUIRED TO INSTALL SEWER SERVICES. THE CONTRACTOR SHALL ALSO TOPSOIL AND SEED AND RESTORE DISTRURBED AREAS AS A RESULT OF THIS CONSTRUCTION TO EXISTING CONDMONS. 10. EXISTING SEWER CONNECTIONS: THE CONTRACTOR SHALL VERIFY SEWER STUB LOCATIONS WITH EXISTING HOMEOWNERS PRIOR TO CONSTRUCTION. SEWER SERVICE CONNECTIONS SHALL BE TYPE A, UNLESS OTHERWISE SPECIFIED ON THE APPROVED PLANS. SEWER STUBS HAVE A MINIMUM SLOPE OF 2% UNLESS OTHERWISE NOTED ON THE APPROVED PLANS. FILE #REZ-21 -05 INSPECTIONS & PERMITS REQUIRED PER SPOKANE COUNTY STANDARD PLANS AND SPECIFICATIONS ACCEPTED FOR CO RU - BY ATE dr-21z 707 SPOKANE COUNTY UTILITIES SEWER PLANS SHORT PLAT NOTES AND DETAILS SPOKANE COUNTY, WASHINGTON SPOKANE VALLEY 'EXPIRE 9/24/ SHEET 3 OF 5 JOB NUMBER 2004-82 G --- �- '. G�— 8 MH 3M 121 6 SIXTH AVENUE mom upi- ,- I- f?: I FA I. I WG I I I _ agsnNG HOUSE L 1 MH 3MA WHIPPLE LANE SEE SHEET 5 SIXTH AVENUE N8:49'56'E • • • i MH 4M _._ 121.6 6 ) __------ N E 1/4 SECTION 21, T. 25 N. S GRAPHIC SCALE 50 0 25 50 ME MEI ( IN FEET ) 1 inch = 50 ft. CURB RETURN TABLE CURVE RADIUS LENGTH TANGENT CHORD DELTA Cl 30,00 47.12 30.00 42.43 90'00O0 C2 30.00 47.12 30.00 42.43 90`.00'00" C3 30.00 47.12 30.00 42.43 90'00'00" C4 30.00 47.12 30.00 42.43 • 90700.00: 2010 2000 1990 I -1 w z co 01 a w u, O c0 0 N Q ye — EXISTING GROUND UNE AT CENTERLINE EXSTING 8" SEWER SLOPE..- 0.0039 FT./FT. 0) w EXS NG 8" SEWER SLO E = 0.0039. FT./FT. co cG 0 cV I•j 10 2000 ta90 7+00 8+00 9+00 10+00 11+00 12+00 100 R. 44 Ea, WIWI CONSTRUCTION NOTES O STATIONING FOR SIXTH AVENUE IS BASED ON BOVAY NORTHWEST PLAN NUMBER 16 OF 45 CONSTRUCTION PACKAGE NO.II.. EXISTING MANHOLE 3M FROM BOVAY NORTHWEST PLAN NUMBER 36 OF 45 FOR U.L.I.D. 88-01 CONSTRUCTION PACKAGE NO.. II. (STA. 8+07.99) EXISTING MANHOLE 4M FROM BOVAY NORTHWEST PLAN NUMBER 36 OF 45 FOR U.L.I.D. 88-01 CONSTRUCTION PACKAGE NO. II. STA. 10+04.99) STA. 9+37.94, 3.39' ± LT. PROVIDE AND INSTALL TYPE "I-48" INLINE MANHOLE PER SPOKANE COUNTY STANDARDS AND DETAIL 1 SHEET 3. THERE IS AN EXISTING SEWER SERVICE TO LOT 1 FROM SIXTH AVENUE SHOWN. EXTEND NEW SERVICE FROM EXISTING TAP TO EASEMENT LINE AS SHOWN. FOR ADDI11ONAL INFORMATION SEE AS —BUILT PLAN AT SPOKANE COUNTY UTILITIES FOR PARCEL NO. 45211.2305. 17'hL. e W 11 PPL E' Po45 s. 'E STOL=E" r PLANS FILE #REZ-21-435 INSPECTIONS & PERMITS REQUIRED PER SPOKANE COUNTY STANDARD PLANS AND SPECIFICATIONS ACCEPTED FOR CON ST U TI_ON BY DA' 14— 61/ SPOKANE COUNTY UTILITIES .AVID. ES EL VATIONS SHOWN ARE BASED ON C.B.M. "HV5-26-3," A "+" ON THE NORTH FLANGE BOLT OF A FIRE HYDRANT, ON THE SOUTH SIDE OF 6TH - AVENUE, +/ 200'EAST OF PERRINE, PER ULID-952 BENCH LEVEL NOTES, DATED 10/26/94. ELEV. = 2007.03 '--'� APPROVAL EVELOPERS DATE. SCALE: RLM SUBMITTAL TO SPOKANE COUNTY UTILITIES HORIZONTAL:. N.A. X 10/04 RLM ORIGINAL PLAN PREPARATION. NO. DATE BY REVISIONS VERTICAL: N.A. PROJ #: 2004.82 DATE: 01/15/07 DRAWN: RLM APPROVED: TRW WHIPPLE CONSULTING ENGINEERS CIVIL AND TRANSPORTATION ENGINEERING 2528 NORTH SULUVAN ROAD SPOKANE VALLEY, WA 99216 PH: 509-893-2617 FAX: 509-926-0227 SEWER PLANS SHORT PLAT-28-05 SIXTH AVE. STA. 8+07..99 TO A 11+04.99 SPOKANE COUNTY, ASHI ,.. T _. SPOKANE VALLEY CALL TWO BUSINESS DAYS BEFORE YOU DIG SHEET 4 OF 5 JOB NUMBER 2004-82