2007, 05-03 SHP-28-05 Water PlansGENERAL NOTES 1. ALL MATERIALS, WORKMANSHIP, AND CONSTRUCTION OF SITE IMPROVEMENTS SHALL MEET OR EXCEED SITE WORK STANDARDS AND THE STANDARDS AND SPECIFICATIONS SET FORTH IN THE SPOKANE COUNTY REGULATIONS/ORDIANCES AND APPLICABLE STATE AND FEDERAL REGULATIONS. WHERE THERE IS CONFLICT BETWEEN THESE PLANS AND THE SPECIFICATIONS, OR ANY APPLICABLE STANDARDS, THE HIGHER QUALITY STANDARD SHALL APPLY. ALL WORK WITHIN PUBLIC R.O.W. OR EASEMENTS SHALL BE INSPECTED AND APPROVED BY THE CITY OF SPOKANE VALLEY INSPECTOR. INSPECTION SERVICES AND CONSTRUCTION CERTIFICATION TO BE PROVIDED BY DESIGNEE OF PROJECT SPONSOR/OWNER. 2. THE CONTRACTOR IS SPECIFICALLY CAUTIONED THAT THE LOCATION AND/OR ELEVATION OF EXISTING UTILITIES, AS SHOWN ON THESE PLANS, IS BASED ON RECORDS OF THE VARIOUS UTILITY COMPANIES AND, WHERE POSSIBLE, MEASUREMENTS TAKEN IN THE FIELD. THE INFORMATION IS NOT TO BE RELIED UPON AS BEING EXACT OR COMPLETE. THE CONTRACTOR MUST CALL THE LOCAL UTILITY LOCATION CENTER AT LEAST 48 HOURS BEFORE ANY EXCAVATION TO REQUEST EXACT FIELD LOCATIONS OF EXISTING UTILITIES. THE CONTRACTOR SHALL VERIFY PERTINENT LOCATIONS AND ELEVATIONS, ESPECIALLY AT THE CONNECTION POINTS AND AT POTENTIAL UTILITY CONFLICTS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO RELOCATE ALL EXISTING UTILITIES THAT CONFLICT WITH THE PROPOSED IMPROVEMENTS SHOWN ON THESE PLANS. 3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL NECESSARY PERMITS FROM ALL APPLICABLE AGENCIES. THE CONTRACTOR SHALL NOTIFY THE CITY OF SPOKANE VALLEY INSPECTOR AT LEAST 48 HOURS PRIOR TO THE START OF ANY EARTH DISTURBING ACTIVITY OR CONSTRUCTION ON ANY AND ALL PUBLIC IMPROVEMENTS. 4. THE CONTRACTOR SHALL COORDINATE AND COOPERATE WITH THE CITY OF SPOKANE VALLEY AND ALL UTILITY COMPANIES WITH REGARD TO RELOCATIONS OR ADJUSTMENTS OF EXISTING UTILITIES DURING CONSTRUCTION AND TO ASSURE THAT THE WORK IS ACCOMPLISHED IN A TIMELY FASHION AND WITH A MINIMUM DISRUPTION OF SERVICE. THE CONTRACTOR SHALL BE RESPONSIBLE FOR CONTACTING ALL PARTIES AFFECTED BY ANY DISRUPTION OF ANY UTILITY SERVICE. 5. THE CONTRACTOR SHALL HAVE ONE (1) SIGNED COPY OF THE APPROVED PLANS, ONE (1) COPY OF THE APPROPRIATE STANDARDS AND SPECIFICATIONS, AND A COPY OF ANY PERMITS AND EXTENSION AGREEMENTS NEEDED FOR THE JOB ON -SITE AT ALL TIMES. 6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL ASPECTS OF SAFETY INCLUDING, BUT NOT LIMITED TO, EXCAVATION, TRENCHING, SHORING, TRAFFIC CONTROL, AND SECURITY. 7. IF, DURING THE CONSTRUCTION PROCESS, CONDITIONS ARE ENCOUNTERED BY THE CONTRACTOR, HIS SUBCONTRACTORS, OR OTHER AFFECTED PARTIES, WHICH COULD INDICATE A SITUATION THAT IS NOT IDENTIFIED IN THE PLANS OR SPECIFICATIONS, THE CONTRACTOR SHALL CONTACT THE ENGINEER IMMEDIATELY. 8. ALL REFERENCES TO ANY PUBLISHED STANDARDS SHALL REFER TO THE LATEST REVISION OF SAID STANDARD, UNLESS SPECIFICALLY STATED OTHERWISE. 9. FOR WORK AFFECTING PUBLIC ROADWAYS OR IF REQUIRED BY THE CITY OF SPOKANE VALLEY THE CONTRACTOR SHALL SUBMIT A TRAFFIC CONTROL AND PHASING PLAN, IN ACCORDANCE WITH M.U.T.C.D. FOR APPROVAL PRIOR TO ANY CONSTRUCTION ACTIVITIES WITHIN OR AFFECTING THE RIGHT-OF-WAY, THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ANY AND ALL TRAFFIC CONTROL DEVICES AS MAY BE REQUIRED BY SAID PLANS. PRIOR TO INSTALLATION A PRECONSTRUCTION CONFERENCE SHALL BE HELD WIN THE CITY OF SPOKANE VALLEY. 10. 11-1E CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL LABOR AND MATERIALS NECESSARY FOR THE COMPLETION OF THE INTENDED IMPROVEMENTS SHOWN ON THESE DRAWINGS OR DESIGNATED TO BE PROVIDED, INSTALLED, CONSTRUCTED, REMOVED OR RELOCATED UNLESS SPECIFICALLY NOTED OTHERWISE. 11. PER AGENCY STANDARDS THE CONTRACTOR SHALL BE RESPONSIBLE FOR KEEPING ROADWAYS FREE AND CLEAR OF ALL CONSTRUCTION DEBRIS AND DIRT TRACKED FROM THE SITE. 12. THE CONTRACTOR SHALL BE RESPONSIBLE FOR RECORDING RECORD INFORMATION ON A SET OF RECORD DRAWINGS KEPT INT THE CONST9UCTtON SITE AND AVAILABLE TO THE CITY OF SPOKANE VALLEY INSPECTOR AT ALL TIMES 13. DIMENSIONS FOR LAYOUT AND CONSTRUCTION ARE NOT TO BE SCALED FROM ANY DRAWING. FOR ADDITIONAL INFORMATION CONTACT THE ENGINEER FOR CLARIFICATION AND NOTE ON 114E RECORD DRAWINGS. 14. ALL EROSION AND SEDIMENT CONTROL (E.S.C.) MEASURES SHALL BE INSTALLED AT THE LIMITS OF CONSTRUCTION PRIOR TO GROUND -DISTURBING ACTIVITY. ALL E.S.C. MEASURES SHALL BE MAINTAINED IN GOOD REPAIR Bt THE CONTRACTOR UNTIL UCHTIME AS THE ENTIRE DISTURBED AREAS ARE STABILIZED WITH HARD SURFACE , R LANDSCAPING. 15. THE CONTRACTOR SHALL SEQUENCE INSTALLATION OF UTILITIES IN SUCH A MANNER AS TO MINIMIZE POTENTIAL UTILITY CONFLICTS. IN GENERAL, STORM SEWER AND SANITARY SEWER SHOULD BE CONSTRUCTED PRIOR TO INSTALLATION OF WATER LINES AND DRY UTILITIES. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO COORDINATE ALL UTILITY RELOCATIONS CONSISTENT WITH THE CONTRACTORS SCHEDULE FOR THIS PROJECT, WHETHER SHOWN OR NOT SHOWN, AS IT RELATES TO THE CONSTRUCTION ACTIVITIES CONTEMPLATED IN THESE PLANS. 16. ALL WORK WITHIN THE PUBLIC RIGHT-OF-WAY IS SUBJECT TO THE JURISDICTION OF THE CITY OF SPOKANE VALLEY ENGINEERING DEPARTMENT AND THE REQUIREMENTS OF THE SPOKANE COUNTY ROAD STANDARDS. 17. ALL CONSTRUCTION OPERATIONS , INCLUDING THE WARMING UP, REPAIR, ARRIVAL, DEPARTURE OR RUNNING OF TRUCKS, EARTH MOVING EQUIPMENT, CONSTRUCTION EQUIPMENT AND ANY OTHER ASSOCIATED EQUIPMENT SHALL GENERALLY BE LIMITED TO THE TIME PERIOD APPROVED BY THE CITY OF SPOKANE VALLEY. 18. BASED ON A REQUIREMENTS FROM THE CITY OF SPOKANE VALLEY AND SPOKANE COUNTY ROAD STANDARDS, THE ENGINEER OR HIS DESIGNEE SHALL PERFORM MATERIALS TESTING AND QUALITY CONTROL ON THE PROJECT AND SHALL SUBMIT COPIES OF DAILY REPORTS, TEST REPORTS, PROJECT CERTIFICATION AND RECORD DRAWINGS TO THE CITY OF SPOKANE VALLEY ENGINEER. 19. NO REVISIONS SHALL BE MADE TO THESE PLANS WITHOUT THE APPROVAL BY THE CITY OF SPOKANE VALLEY ENGINEER AND NOTIFICATION OF THE ENGINEER OF RECORD. 20. ONSITE GRADING SHALL BE IN ACCORDANCE WITH THE APPROVED GRADING PLAN AND E.S.C. PLAN. ANY IMPORT OR EXPORT OF MATERIAL SHALL BE FROM A PREAPPROVED SOURCE/DESTINATION AND COORDINATED WITH THE CITY OF SPOKANE VALLEY DEPARTMENT OF BUILDING AND PLANNING AT 509-921-1000. GRADING ON THIS SITE OR ANY OTHER SITE MUST COMPLY WITH ALL DEVELOPMENT REGULATIONS INCLUDING, BUT NOT LIMITED TO , GRADING PERMITS, S.E.P.A. REVIEW, TIMBER HARVEST PERMITS, CRITICAL AREAS, FLOODPLAINS, DESIGNATED DRAINAGEWAYS, ETC. WATER PURVEYOR POWER DISTRICT ENGINEER MODERN ELECTRIC WATER CO. NORTH 904 PINES ROAD SPOKANE VALLEY, WA 99206 PHONE 509-928-4540 FAX: 509-755-9000 CONTACT: DAVE JOHNSON SEWER SPOKANE COUNTY UTILITIES 1026 WEST BROADWAY AVENUE SPOKANE, WASHINGTON 99260 PHONE: 509-477-3604 FAX: 509-477-4715 CONTACT: BILLY URHAUSEN HEALTH SPOKANE REGIONAL HEALTH 1101 WEST COLLEGE AVENUE SPOKANE, WASHINGTON 99260 PHONE: 509-324-1560 FAX: 509-324-3603 CONTACT: DON COPLEY MODERN ELECTRIC WATER CO. NORTH 904 PINES ROAD SPOKANE VALLEY, WA 99206 PHONE: 509-928-4540 FAX: 509-755-9000 CONTACT: JOHN McFEELY STREETS CITY OF SPOKANE VALLEY 11707 E. SPRAGUE AVENUE SPOKANE VALLEY, WA 99206 PHONE: 509-688-0228 PHONE: 509-921-1008 CONTACT: HENRY M. ALLAN, P.E. SURVEYOR WHIPPLE CONSULTING ENGINEERS 2528 NORTH SULLIVAN ROAD SPOKANE VALLEY, WA 99216 PHONE: 509-893-2617 FAX: 509-926-0227 CONTACT: TERRY IRWIN, P.L.S. SIMPSON ENGINEERS 909 NORTH ARGONNE ROAD SPOKANE VALLEY, WA 99206 PHONE: 509-926-1322 PHONE: 509-926-1323 CONTACT: KEVIN McMULKIN, P.E. TELEPHONE QWEST 904 NORTH COLUMBUS SPOKANE, WASHINGTON, 99202 PHONE: 509-455-2580 FAX: 509-455-2104 CONTACT: DAVE CLARK ENGINEER WHIPPLE CONSULTING ENGINEERS 2528 NORTH SULLIVAN ROAD SPOKANE VALLEY, WA 99216 PHONE: 509-893-2617 FAX: 509-926-0227 CONTACT: TODD R. WHIPPLE, P.E. 0 RT PLAT 2 8 05 WATER PLANS SPOKANE VALLEY SPOKANE COUNTY, WASHINGTON NE 1/4 SECTION 21, T. 25 N., R. 44 E., W.M. 6TH. AVENUE 10 _G- Ea_ . . EC MI . - r N8ti.49.56"E -12 - 74. T ----- 7.77 ,„, a• .4==i1S?:. T • ;:791116116111161116111:.36111iiigaliZ SPIWISMMUlarga MillaRata2 .p 03 0 SITE PLAN A10.17.41,27trWav LAKE 6 -:; 2 F37.921.. X 260.36' co HAMME 5 N89-47-53-E, r - EAD 0)4 4 03 8.5.821 _ 8 L_ r- - q, Q 41' NOM •••• MINIM NON1/0 0.111•1M *MO N E GRAThlIC SCALE 40 0 20 40 80 ( IN FEET ) 1 inch = 40 ft. SCALE 1" = 40' ABBREVIATIONS ACT. LEN. .... ACT LENGTH PRC BCR BEGINNING OF CURVE PT BDRY BOUNDARY CO. SEWER CLEANOUT CSTC CRUSHED SURFACE TOP COURSE SI CT. COURT SS DIA DIAMETER STA. ECR END OF CURB STA EXIST. EXISTING TG G GRADE TC GB GRADE BREAK FT. / FT. FEET PER FOOT HYD HYDRANT I.E. INVERT ELEVATION LN. LANE LT. LEFT MH MANHOLE MCR MID POINT OF CURVE PC POINT OF CURVE PET. PETROLEUM PI POINT OF INTERSECTION FIRE DEPARTMENT FIRE DISTRICT NO. 1 EAST 10319 SPRAGUE AVENUE SPOKANE VALLEY, WA 99206 PHONE: 509-928-1700 FAX: 509-892-4125 CONTACT: RICK FREIER CABLE SOLID WASTE POINT OF REVERSE CURVE POINT OF TANGENCY RIM EL. RIM ELEVATION RD ROAD RT. RIGHT STREET INTERSECTION SANITARY SEWER STATION LEN STATION LENGTH TOP OF GRATE TOP OF CURB WASTE MANAGEMENT PHONE: 509-466-3400 COMCAST BROADBAND 1717 EAST BUCKEYE SPOKANE, WASHINGTON, 99207 PHONE: 509 +81 1031 Piss" - 4917 €X1EN91421 CONTACT: BRYAN RICHARDSON OWNER RAY WILLMAN 12104 E. 6TH. AVENUE SPOKANE VALLEY, WA 99206 PHONE: 509-924-1585 CONTACT: RAY WILLMAN WATER SUPPLIER CERTIFICATION STATEMENT A. MODERN ELECTRIC WATER COMPANY WITH STATE IDENTIFICATION NUMBER 556008 HAS APPROVED THIS WATER PLAN FOR WILLMAN ESTATES SP-28-05. THIS WATER PLAN WILL SATISFY OUR NEEDS IN PROVIDING AN ADEQUATE WATER SYSTEM AND FACILITIES FOR DOMESTIC AND FIRE PROTECTION FOR THE ABOVE REFERENCED PROJECT. vikkFid kA) Signature itle 20 7t67 Date FIRE DISTRICT CERTIFICATION STATEMENT FIRE DISTRICT NO. 1 HAS APPROVED THIS WATER PLAN FOR WILLMAN ESTATES SP-28-05. THIS PLAN IS IN CONFORMANCE WITH OUR REQUIREMENTS AND WILL SATISFY OUR NEEDS IN PROVIDING AN ADEQUATE WATER SYSTEM AND FACILITIES FOR FIRE PROTECTION PURPO ES TO ALL SITES IN THE ABOVE NAMED PROJECT. kif Ms As Mt- S /sic nature Title Date SPOKANE REGIONAL HEALTH DISTRICT STATEMENT THE SPOKANE REGIONAL HEALTH DISTRICT HAS APPROVED THIS WATER PLAN AS HAVING MET ALL APPLICABLE COUNTY DISTRICT REQUIREMENTS. Qts Z2-0 Signature Title Date 1/41-iiiLV.D. 88' ATIONS SHOWN ARE BASED ON C.B.M. "HV5-26-3," A "+" ON THE NORTH FLANGE BOLT OF A FIRE HYDRANT, ON THE SOUTH SIDE OF 6TH AVENUE, +/- 200EAST OF PERRINE, PER ULID-952 BENCH LEVEL NOTES, DATED 10/26/94. ELEV = 2007.03 DEVELOPER'S APPROVAL 2A/07 DATE SCALE: NO. 09/28 DATE RLM RLM RLM SUBMITTAL TO MODERN ELECTRIC WATER CO. FOR APPROVAL SUBMITTAL TO MODERN ELECTRIC WATER CO. ORIGINAL PLAN PREPARATION HORIZONTAL: AS SHOWN BY REVISIONS VERTICAL: N.A. PROJ #: 2004.82 DATE: 01/24/07 DRAWN: RLM APPROVED: TRW CALL "IWO BUSINESS DAYS BEFORE YOU DIG 111111"11:MIIII --11111‘174--e11111111111 al li ' "ifilaTilignialliar Al Milt AlITIllnit irillall1111110wituiltit AillffarlyclirririllIrd ,k ilesaprjoirarsirdillECE IMO all /11tmain Intaii, sommulli p kiwi VilljAmanigia rintingi:MOURrellili C, it6171:211.* NtrA 747 PAI "" italtrialre litilmiluirATI wrISSIMAIIIIIM , Als MO Oa rossileb..„arsomes s lisissurnownsa::::::4 _. me lte .-w.1•1 0 iiiiiii11011. II VICINITY MAP FIRE HYDRANT LOCATIDNS AND DISTRIBUTION THE CITY OF SPOKANE HAS ADOPTED THE 2003 INTERNATIONAL FIRE CODE (IFC). PER THE 203 IFC THE FOLLOWING FLOW AND SPACING GUIDELINES APPLY 2003 INTERNATIONAL FIRE CODE - APPENDIX C - FIRE HYDRANT LOCATIONS AND DISTRIBUTION IFC SECTION C101 - GENERAL C101.0 - SCOPE. FIRE HYDRANT SHALL BE PROVIDED IN ACCORDANCE WITH THIS APPENDIX FOR ME PROTECTION OF BUILINGS, OR PORTIONS OF BUILDINGS, HEREAFTER CONSTRUCTED. IFC SECTION C102 - LOCATION C102.1 - FIRE HYDRANT LOCATIONS. FIRE HYDRANTS SHALL BE PROVIDED ALONG REQUIRED FIRE APPARATUS ACCESS ROAD ANDS ADJACENT PUBLIC STREETS IFC SECTION C103 - NUMBER OF FIRE HYDRANTS C103.1 - FIRE HYDRANTS AVAILABLE THE MINIMUM NUMBER OF FIRE HYDRANTS AVAILABLE TO A BUILDING SHALL NOT BE LESS THAN THAT LISTED IN TABLE C105.1. THE NUMBER OF FIRE HYDRANTS AVAILABLE TO A COMPLEX OR SUBDIVISION SHALL NOT BE LESS THAN THAT DETERMINED BY SPACING REQUIREMENTS LISTED IN TABLE C105.1 WHEN APPLIED TO FIRE APPARATUS ACCESS ROADS THE PERIMETER PUBLIC STREETS FROM WHICH FIRE OPERMIONS COULD BE CONDUCTED. in SECTION C104 - CONSIDERATION OF EXISTING FIRE HYDRANTS C104.1 - EXISTING FIRE HYDRANTS. EXISTING FIRE HYDRANTS ON PUBLIC STREETS ARE ALLOWED TO BE CONSIDERED AS AVAILABLE EXISTING FIRE HYDRANTS ON ADJACENT PROPERTIES SHALL NOT BE CONSIDERED AVAILABLE UNLESS FIRE APPARATUS ACCESS ROADS EXTEND BETWEEN PROPERTIES AND EASEMENTS ARE ESTABLISHED TO PREVENT OBSTRUCTION OF SUCH ROADS IFC SECTION C105 - DISTRIBUTION OF FIRE HYDRANTS C105.1 - HYDRANT SPACING. THE AVERAGE SPACING BETWEEN FIRE HYDRANTS SHALL NOT EXCEED THAT LISTED IN TABLE C105.1 EXCEPTION: THE FIRE CHIEF IS AUTHORIZED TO ACCEPT A DEFICIENCY OF UP TO 10 PERCENT WHERE EXISTING FIRE HYDRANTS PROVIDE A 1 OR A PORTION OF THE REQUIRED FIRE HYDRANT SERVICE. REGARDLESS OF THE AVERAGE SPACING, FIRE HYDRANTS SHALL BE LOCATED SUCH THAT ALL POINTS OF STREETS AND ACCESS ROADS ADJACENT TO A BUILDING ARE WITHIN THE DISTANCES LISTED IN TABLE C105.1. FIRE FLOW REQUIREMENTS (GPM) MIN. NUMBER OF HYDRANTS AVG. SPACING BETWEEN HYDRANTSmo (FEET) MAX. DISTANCE FROM ANY POINT ON STREET OR ROAD TO FRONTAGE TO A HYDRANT 00 1750 OR LESS 1 500 250 2000 TO 2250 2 450 225 2500 3 450 225 3000 3 400 225 3500 TO 4000 4 350 210 4500 TO 5000 5 300 180 5500 6 300 180 6000 6 250 150 6500 TO 7000 7 250 150 7500 OR MORE 8 OR MORE (e) 200 120 FOOTNOTES FOR SI: 1 FOOT = 304.8mm, 1 GPM = 3.785 L/m REDUCE BY 100 FEET FOR DEAD-END STREETS OR ROADS. b. WHERE STREETS ARE PROVIDED WITH MEDIAN DIVIDERS WHICH CAN BE CROSSED BY FIRE FIGHTERS PULLING HOSE LINES, OR WHERE ARTERIAL ARE PROVIDED WITH FOUR OR MORE TRAFFIC LANES AND HAVE A TRAFFIC COUNT OF MORE THAN 30000 VEHICLES PER DAY, HYDRANT SPACING SHALL AVERAGE 500 FEET ON EACH SIDE OF THE STREET AND BE ARRANGED ON AN ALTERNATING BASIS UP TO A FIRE FLOW REQUIREMENT OF 7000 GPM AND 400 FEET FOR HIGHER FIRE FLOW REQUIREMENTS. WHERE NEW WATER MAINS ARE EXTENDED ALONG STREETS WHERE HYDRANT ARE NOT NEEDED FOR PROTECTION OF STRUCTURES OR SIMILAR FIRE PROBLEMS, FIRE HYDRANTS SHALL BE PROVIDED AT SPACING NOT TO EXCEED 1000 FEET TO PROVIDE FOR TRANSPORTATION HAZARDS. d. REDUCE BY 50 FEET FOR DEAD-END STREETS OR ROADS. e. ONE HYDRANT FOR EACH 1000 GALLONS PER MINUTE OR FRACTION THEREOF. INDEX TO PLAN SHEETS SHEET NO. 1 COVER AND NOTES SHEET NO. 2 DEMOLITION PLAN SHEET NO. 3 WATER PLAN - NOTES - DETAILS WHIPPLE CONSULTING ENGINEERS CIVIL AND TRANSPORTATION ENGINEERING 2528 NORTH SULUVAN ROAD SPOKANE VALLEY, WA 99216 PH: 509,898-2617 FX: 509-926-0227 WILLMAN ESTASTES WATER PLANS SHORT PLAT28-05 COVER SHEET SPOKANE VALLEY SPOKANE COUNTY, WASHINGTON EXPIRES 9/24/ifirk SHEET OF 3 JOB NUMBER 2004-82 N:.E 1/4 SIECTVON 2 1 9 T. 2:5 N:.y R. 44 E.9 W.M. 6TH. AVENUE to -G— 00 --------- G --------------- -10 3 0 64 N8§'49'56"E b 14, W.sp 260- -89! W,�� S _494�66±' p —7�::=,777� 7=7 77r7� .7*po6T— r C) F 0 i0 < 0 0 w F- W_ � 3' 5 > Cn > < 7z 3: ®r w 0 > in X w 10 PX UJ C-0 EXISTING HOUSE Z 122.00'--- 06 I E. 12104 6TH. AVE. 00 0 L Ll.Ow o _j F 0 a- 4 L6 1 oj67' 0 /or Z6 tK -lu- - � N 0IV lb " .1 1 4 � � ,N. - I I (- 0 'Co 8. 0, c) tK 115.06 i121.29 N. ' \-3(D 2 4* 0 2W -C) s Tum to CP Co Clq Q 04 (6 NN 00 Q� 24!' 30" 6 ol F CD 67.80' o N89-4956"72.56E t 04 o T_ 6. 19.14' 86.62:� 14,23 WH PPLE LANE HAMMERHEAD 6 5 4 4 0-) 00 00 6 ------------I O I � 87.92'\ 6 260.36' N894T53"E F' I N SITE PLAN SCALE: 1" = 30' DEMOLITION NOTESr O1 TREE TO BE REMOVED. EXISTING WATER METER TO RELOCATED PER MODERN ELECTRIC WATER CO. STANDARDS. O EXISTING POWER AND LIGHT POLE TO BE RELOCATED BY MODERN ELECTRIC WATER CO. PAID FOR BY DEVELOPER. D EXISTING FENCE TO BE REMOVED AND / OR REPLACED AS AGREED ON WITH OWNER. O EXISTING HOSE BIBB TO BE REMOVED AND CAPPED AS AGREED ON WITH OWNER. O EXISTING FENCE TO BE REMOVED. OEXISTING SHED TO BE REMOVED OR RELOCATED AS AGREED UPON WITH OWNER. N W E s GRAPHIC SCALE 30 0 15 30 60 IN FEET 1 inch = 30 ft. UNDERGROUND SERVICE ALERT ONE —CALL NUMBER 456-8000 CALL TWO BUSINESS DAYS BEFORE YOU DIG 25462 4'-6" MINIMUM FIRE HYDRANT " el In •res;',.• • • • • • • - tfi•• 1'4 x•W rei-"k • Cs SAVLSve • ts400-01170- 18" x 24" x 6" BLOCK WITH LIFTING EYE 4" x 8" x 16" - CONCRETE BLOCK TYPICAL FIRE HYDRANT DETAIL VALVE BOX, "TYLER" NO. 6855 TOP SECTION, (FLANGED) WITH COVER, BOTTOM SECTION, "TYLER" NO. 6855 NOTE: FOR FIRE HYDRANTS, SEE "MODERN ELECTRIC WATER co." STANDARD SPECIFICATIONS. FINISHED GRADE MECHANICAL JOINT CONNECTION 3/4" COLD ROLL SHACKLE RODS WATER MAIN 6" M.J. VALVE TEE NOT TO SCALE 3/4" GRAVEL 6" DJ. PIPE. 6" PVC. C900, CL 150 FITTINGS AND LOCATION NUMBER OF FULL LENGTHS EACH WAY PIPE • SIZE 18" 12" 10" 8" 6" 4" 90' BENDS, TEES, CROSSES, VALVES AND DEAD ENDS 6 6 6 5 4 3 11 1/4BENDS 2 2 2 2 1 1 22 1/2' BENDS 3 3 3 3 2 2 45' BENDS 5 5 5 4 3 3 DESIGN PRESSURE = 58 P.S.I. RESTRAINED JOINT TAE3LE NOT TO SCALE BEARING AREA THRUST 1 vckos' NOTE: THE FOLLOWING TABULATION IS BASED UPON A MAXIMUM WATER PRESSURE OF 150 P.S.I. W111-I A MINIMUM BEARING CAPACITY OF 2,000 LBS./SQ. FOOT. FOR OTHER VALUES, THE BEARING AREA SHOULD BE ADJUSTED PROPORTIONATELY. COMPACTED EARTH 24" x 36" x 6" BLOCK WITH UF1ING EYE #5 REBAR FOR 6" AND 8" PIPE #6 FOR 10" AND 12" PIPE BEARING AREA PER TABLE (TYP.) (FOR VALVES, TEES, OR CROSSES WITH DIRECTLY ATTACHED VALVES, PLUGS, OR BLIND FLANGES) TYPICAL STEEL STRAP INSTALLATION NOT TO SCALE PIPE DIAMETER ”D" MINIMUM BEARING AREA OF BLOCK IN SQUARE FEET TEES AND ENDS 90' BEND 45' BEND 22 1/2' BEND 4" 1.5 1.8 1.5 1.5 6" 2.9 4.0 2.3 1.5 8" 5.0 7.2 3.8 2.6 10" 8.0 11.3 6.0 4.0 12" 11.5 16.2 8.8 4.5 14" 15.6 22.0 11.9 6.0 16" 20.1 28.5 15.4 7.8 THRUST BLC3CK DETAIL NOT TO SCALE PIPE DIAMETER VOLUME OF THRUST BLOCKING (CU. YDS.) &RID BID 2g 1END/2. 1 IBE1/ND4. 6" 1.8 0.9 0.4 -- - 8" 12 1.7 0.8 03 10" 4.9 2.6 1.3 0.5 12" 7.cL 3.7 1.8 0.8 NOTE: THRUST BLOCK VOLUME BASED ON 4000 LBS /CU yd. FOR CONCRETE AND A HYDRAUUC TEST PRESSURE OF 150 P.S.I. THRUST BLOCK VOLUMES SHALL BE PROPORTIONALLY ADJUSTED FOR DIFFERENT HYDRAULIC TEST PRESSURES. VERTICAL THRUST BLOCKING TABLE NOT TO SCALE N.A.V.D. 88 ELEVATIONS SHOWN ARE BASED ON C.B.M. "HV5-26-3," A "+" ON THE NORTH FLANGE BOLT OF A FIRE HYDRANT, ON. THE SOUTH SIDE OF 6TH AVENUE, +/- 200' EAST OF PERRINE, PER ULID-952 BENCH LEVEL NOTES, DATED 10/26/94. ELEV. = 2007.03 NOT USED BLOWOFF DETAIL NOT TO SCALE NE 1/4 SECTION 21, T. 25 Noy R. 44 E., WNW. USE FORD MODEL C52 UDS METER WITH RADIO READ UNIT CAP 111 WATER SERVICE DETAIL NOT TO SCALE LEGEND TYLER TOP SECTION VALVE BOX #6855 /.>\ \ r ',' ' \i'' \ ' • ......„..,,,......% \\\ \\\\ ,.....-:6 ... .,7\r NOTE; THE CONTRACTOR HAS THE OPTION TO CONTINUE SERVICE LINE INTO BUILDING. WHEN METER IS INSTALLED, M.E.W.CO. WILL CUT SERVICE UNE AND INSERT METER SETTING. //- CURB BOX FROM M.E.W.CO. / \ FORD B11 444 BALL VALVE 1" GALV. PIPE "ROMAC" 20 SADDLE FORD B11 444 BALL VALVE • MODERN (M.E.W.00.) GENERAL NOTES EXISTING ) GENERAL ROADWAY CENTER LINE RIGHT OF WAY LINE PROPERTY LINE EASEMENT LINE FENCE CURB PAVEMENT GRAVEL CONCRETE BUILDINGS & STRUCTURES MONUMENT S AN ITARY SEWER ) SANITARY SEWER o ) ) V FH WS 0 gAVRS WWM 0 ABLOWOFF MH DW CD CB 0 GM MANHOLE CLEANOUT SEWER SERVICE WATER WATER LINE VALVE FIRE HYDRANT SERVICE METER BLOVVOFF AIR VACUUM RELIEF STATION STORM DRAINAGE DRAINAGE LINE MANHOLE DRYWELL CATCH BASIN DITCH NATURAL GAS GAS LINE VALVE METER AlijA,RS PROPOSED • 49( 04FH WS• WM RI nwnp-F CB G rmv TELEPHONE - POWER DT DT BURIED TELEPHONE -0- PP POWER OR TELEPHONE POLE or or BURIED POWER A T TP TR TV GA PV )LP ID TRANSFORMER PAD TELEPHONE RISER TELEPHONE VAULT OVERHEAD POWER GUY ANCHOR POWER VAULT LIGHT POLE El GM DT DT -0- or or TP UTR TV T ID GA PV LP )1( 1. ALL MATERIALS AND INSTALLATION PROCEDURES SHALL CONFORM TO THE REQUIREMENTS OF THESE PLANS, MODERN ELECTRIC WATER CO. STANDARDS AND APPUCABLE PORTIONS OF A.W.W.A. AND A.P.W.A. 2. SIMPSON ENGINEERS, AT 926-1322, MUST BE CALLED BEFORE ANY TRENCH CLOSURES 3. MODERN ELECTRIC WATER CO., AT 928-4540, MUST BE CALLED BEFORE ANY TRENCH CLOSURES. 4. WATER MAIN LOCATION MUST BE APPROVED BY M.E.W.CO. 5. ALL MATERIALS MUST BE INSPECTED AND APPROVED BY M.E.W.CO. PRIOR TO INSTALLATION. 6. WATER MAINS TO BE DISINFECTED TO THE SATISFACTION OF THE W.S.D.O.H. 7. WATER MAINS TO BE PRESSURE TESTED AT 150 P.S.I. FOR AT LEAST 30 MINUTES TO THE SATISFACTION OF SIMPSON ENGINEERS. 8. WATER MAINS TO HAVE 4'-6" MINIMUM AND 5'-6" MAXIMUM COVER. 9. MODERN ELECTRIC WATER CO. SHALL OBTAIN STREET OPENING PERMIT FROM SPOKANE COUNTY PRIOR TO CONSTRUCTION, OTHER THAN THAT STIPULATED IN "DETAILED" SPECIFICATIONS. 10. FIRE HYDRANT ASSEMBUES AND THEIR INSTALLATION SHALL BE ACCORDING TO MODERN ELECTRIC WATER CO. STANDARD SHEET, DATED 2/22/83. 11. ALL MATERIALS MUST BE NEW. 12. THRUST BLOCKS SHALL BE PRECAST, REINFORCED CONCRETE, 6" x 24" x 36" MODERN ELECTRIC WATER CO. STANDARD. 13. WATER MAIN SHALL BE A MINIMUM OF TEN FEET FROM SANITARY SEWER LINES. 2A/07 E ELOPER'S APPROVAL DATE NO. 10/04 DATE RLM RLM BY 14. WATER MAIN AND WATER SERVICES CROSSING SANITARY SEWERS WITH LESS THAN 18" SEPARATION WITH SANITARY SEWERS MUST BE SLEEVED 20 FEET (NO JOINTS) WITH 10 FEET EACH SIDE OF SEWER. 15. WATER SERVICES MUST HAVE BALL VALVES ON SERVICE CONNECTIONS WITH TRAFFIC MODEL VALVE BOXES, AS USTED IN "DETAILED" SPECIFICATIONS. 16. THRUST BLOCKS SHALL BE INSTALLED AT ALL HORIZONTAL AND VERTICAL BENDS OF 22-1/2 DEGREES OR GREATER AND AT ALL TEES. 17. WATER MAINS TO BE CLASS 150 A.W.W.A. C900 PVC PIPE. 18. WATER METERS AND VAULTS TO BE PROVIDED AND INSTALLED BY M.E.W.CO. AT DEVELOPERS COST. 19. MODERN ELECTRIC WATER CO. REQUIRES PREPAYMENT OF ESTIMATED COST OF CONNECTION TO ITS WATERMAIN. 20. NO WATER MAIN SHALL BE CONSTRUCTED THROUGH A "208" DRAINAGE SWALE OR POND. 21. DEVELOPER/OWNER IS TO GIVE MODERN ELECTRIC WATER CO. A 12.00' WIDE UTIUTY EASEMENT 6.00' ON EACH SIDE OF 4 " AND 2" WATERMAINS FIRE HYDRANT UNES AND FIRE HYDRANTS ON THEIR PROPERTY 22. WATER VALVE BOXES TO BE "TYLER" 6855-16T (TOP) AND 6855-368 (BOTTOM). 23. DUPLEXES REQUIRE 2 SERVICES UNLESS ZERO LOT UNE OPTION IS WAIVED. swum -rue. TO 'MODERN ELECTRIC WATER CO. FOR APPROVAL ORIGINAL PLAN PREPARATION REVISIONS VERTICAL: N.A. PROJ #: DATE: DRAWN: RLM 2004.82 01/24/07 APPROVED: TRW --------- I 6- Aczt9gt_ c_10 _E. ___ N8jr497067E - i it • CII P -• f•,,,,,,A.,,,,,,,,,,,,i......0_7•A-,4,-, 4- - " - - . ' 1 .--""V" -'';'' ' ''', '''''•:"' - . e''''.7-r--- - -.- - - :",-- ,7,senl-,,fg4,Akkairb. ..;,-, :1,zi, iwzArgr,t_!:z,-,--ae, - - ., ...--..,..._.:,-,,,,,., ., ,,,,,,,q,-.-1,17.4.7,4.1..... • - ' :•.. ,:tsi,4,4,-.07,- -.me. •••••• Amway arodommailioneffincemortemoifts. .... ...,_ P • -c. ,_ . ,1-.. ,Il 10.67' SITE PLAN 2 36' N89'4 '"E 1.0- 1 r- - CALL TWO BUSINESS DAYS BEFORE YOU DIG 2°c-fp V' 41, GRAPHIC SCALE 30 0 15 30 60 SCALE: 1" = 30' CONSTRUCTION NOTES ( IN FEET ) 1 inch = 30 ft. SIXTH AVENUE - STATIONING ON SIXTH AVENUE IS BASED ON SPOKANE COUNTY SEWER PROJECT (U.L.I.D. 88-01) PER BOVAY NORTHWEST DRAWING 36 OF 45, CONSTRUCTION PACKAGE NO. II. STA. 9+52.94, 12.50' ± RT., CONNECTION TO EXISTING 8" WATER MAIN WITH TAPPING TEE AND 8" RESILIENT SEAT GATE VALVES PER MODERN ELECTRIC WATER CO., PAID FOR BY DEVELOPER. WHIPPLE LANE - STA. 11+90.00, RT. PROVIDE AND INSTALL 8" x x 6" D.I. TEE FOR FIRE HYDRANT WITH 8" x 4" D.I. REDUCER ON SOUTH END PER MODERN ELECTRIC WATER CO. STANDARDS. PROVIDE AND INSTALL 4" CLASS 150 A.W.W.A. C900 PVC PIPE PER MODERN ELECTRIC WATER CO. STANDARDS. STA. 10+19.00, 9.00' RT. 4" x x 2" TEE WITH THRUST BLOCK PER MODERN ELECTRIC WATER CO. STANDARDS. WHIPPLE LANE HAMMERHEAD - PROVIDE AND INSTALL 2" A.W.W.A. CLASS 150 C900 PVC PIPE PER MODERN ELECTRIC WATER CO. STANDARDS. STA. 10+03.00, 9.00' LT. PROVIDE AND INSTALL 2" END CAP PER MODERN ELECTRIC WATER CO. STANDARDS. STA. 10+07.00, 9.00' LT. PROVIDE AND INSTALL WATER SERVICE TAP TO LOT 6 WITHIN 3' OF END OF 2" PER MODERN ELECTRIC WATER CO. STANDARDS AND DETAIL 2 THIS SHEET. STA. 11+17.00, 9.00' LT. PROVIDE AND INSTALL 2" END CAP PER MODERN ELECTRIC WATER CO. STANDARDS. STA. 11+14.00, 9.00' LT. PROVIDE AND INSTALL SERVICE TAP TO LOT 4 WITHIN 3' OF END OF 2" PER MODERN ELECTRIC WATER CO. STANDARDS AND DETAIL 2 THIS SHEET. WHIPPLE CONSULTING ENGINEERS CIVIL AND TRANSPORTATION ENGINEERING 2528 NORTH SULLIVAN ROAD SPOKANE VALLEY, WA 99216 PH: 5M-893-2617 FAX: 509-926-0227 W LLNIAN ESTATES WATER PLANS SHORT PLAT-28-05 WATER PLAN - DETAILS SPOKANE VALLEY SPOKANE COUNTY, WASHINGTON lid EXPIRES 9/24/ SHEET 3 OF 3 JOB NUMBER 2004-82