BUILDING PLANS - BLD-2024-0696737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216TITLE SHEET & INDEX G-001 FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 HOMEWOOD SUITES by HILTON SPOKANE VALLEY, WA 13515 E. Carlisile Avenue Spokane Valley, WA 99216 PID: 45101.0401 BID/PERMIT SET MAY 31, 2024 GENERAL G-001 TITLE SHEET & INDEX G-002 PROJECT INFORMATION G-003 BUILDING DEVELOPMENT INFORMATION STRUCTURAL S-001 GENERAL STRUCTURAL NOTES S-002 ABBREVIATIONS & LEGENDS S-003 SPECIAL INSPECTIONS & TESTING S-004 TYPICAL DETAILS - CONCRETE S-005 TYPICAL DETAILS - WOOD S-006 TYPICAL DETAILS - WOOD S-007 TYPICAL DETAILS - STEEL S-008 TYPICAL DETAILS - STEEL S-101 OVERALL FLOOR/FOUNDATION PLAN & 1ST FLOOR WALLS S-102 OVERALL FLOOR 2 FRAMING PLAN & 2ND FLOOR WALLS S-103 OVERALL FLOOR 3 FRAMING PLAN & 3RD FLOOR WALLS S-104 OVERALL FLOOR 4 FRAMING PLAN & 4TH FLOOR WALLS S-105 OVERALL FLOOR 5 FRAMING PLAN & 5TH FLOOR WALLS S-106 OVERALL ROOF FRAMING PLAN & PARAPET WALLS S-121 FLOOR FOUNDATION PLAN - WEST WING S-122 FLOOR FOUNDATION PLAN - EAST WING S-123 PORTE COCHERE FOUNDATION & ROOF FRAMING PLANS S-124 FLOOR 2 FRAMING PLAN - WEST WING S-125 FLOOR 2 FRAMING PLAN - EAST WING S-126 FLOORS 3-5 FRAMING PLANS - WEST WING S-127 FLOORS 3-5 FRAMING PLANS - EAST WING S-128 ROOF FRAMING PLAN - WEST WING S-129 ROOF FRAMING PLAN - EAST WING S-130 CANOPY FRAMING PLAN & STEEL FRAME ELEVATIONS S-301 FOUNDATION DETAILS S-401 FLOOR FRAMING DETAILS S-402 FLOOR FRAMING DETAILS S-501 ROOF FRAMING DETAILS S-502 ROOF FRAMING DETAILS S-601 ENLARGED BALCONY PLANS & DETAILS ARCHITECTURAL A-001 CODE PLANS A-002 BUILDING ENVELOPE & ACCESIBILITY PLANS A-010 OVERALL SITE PLAN A-101 OVERALL 1ST FLOOR PLAN A-102 OVERALL 2ND FLOOR PLAN A-103 OVERALL 3RD FLOOR PLAN A-104 OVERALL 4TH FLOOR PLAN A-105 OVERALL 5TH FLOOR PLAN A-106 ROOF PLAN A-107 LOWER ROOF PLAN A-111 OVERALL 1ST FLOOR REFLECTED CEILING PLAN - WEST WING A-112 OVERALL 1ST FLOOR REFLECTED CEILING PLAN - EAST WING A-113 OVERALL TYP. 2ND TO 5TH FLOOR REFLECTED CEILING PLAN- WEST WING A-114 OVERALL TYP. 2ND TO 5TH FLOOR REFLECTED CEILING PLAN- EAST WING A-121 1ST FLOOR CONTRUCTION PLAN - WEST WING A-122 1ST FLOOR CONTRUCTION PLAN - EAST WING A-123 TYPICAL 2ND-5TH FLOOR CONTRUCTION PLAN - WEST WING A-124 TYPICAL 2ND-5TH FLOOR CONTRUCTION PLAN - EAST WING A-131 1ST FLOOR FINISH PLAN - WEST WING A-132 1ST FLOOR FINISH PLAN - EAST WING A-133 TYPICAL 2ND-5TH FLOOR FINISH PLAN - WEST WING A-134 TYPICAL 2ND-5TH FLOOR FINISH PLAN - EAST WING A-201 BUILDING ELEVATIONS A-202 BUILDING ELEVATIONS A-301 BUILDING SECTIONS A-302 BUILDING SECTIONS A-401 ENLARGED EV PARKING & PET RELIEF AREA A-402 ENLARGED STORAGE SHED & TRASH ENCLOSURE A-403 ENLARGED COURTYARD PLANS A-404 ENLARGED OUTDOOR KITCHEN PLANS A-405 ENLARGED OUTDOOR KITCHEN ELEVATIONS, SECTIONS &DETAILS A-406 ENLARGED OUTDOOR KITCHEN DETAILS A-407 ENLARGED PORTE COCHERE PLAN A-411 UNIT PLANS - EFFICIENCY STUDIO A-411A UNIT PLANS - EFFICIENCY STUDIO - ELEC, DATA & FLOORFINISH PLAN A-411B UNIT INT. ELEVATIONS - EFFICIENCY STUDIO A-412 UNIT PLAN - EFFICIENCY STUDIO ADA MOBILITY A-412A UNIT PLAN - EFFICIENCY STUDIO ADA MOBILITY - ELEC, DATA& FLOOR FINISH PLAN A-412B UNIT INT. ELEVATIONS - EFFICIENCY STUDIO ADA MOBILITY A-413 UNIT PLAN - EFFICIENCY STUDIO ENLARGED A-413A UNIT PLAN - EFFICIENCY STUDIO ENLARGED - ELEC, DATA &FLOOR FINISH PLAN A-413B UNIT INT. ELEVATIONS - EFFICIENCY STUDIO ENLARGED A-414 UNIT PLAN - KING STUDIO A-414A UNIT PLAN - KING STUDIO - ELEC, DATA & FLOOR FINISH PLAN A-414B UNIT INT. ELEVATIONS - KING STUDIO A-415 UNIT PLAN - KING STUDIO ADA MOBILITY A-415A UNIT PLAN - KING STUDIO ADA MOBILITY - ELEC, DATA &FLOOR FINISH PLAN A-415B UNIT INT. ELEVATIONS - KING STUDIO ADA MOBILITY A-416 UNIT PLAN - KING STUDIO ENLARGED A-416A UNIT PLAN - KING STUDIO ENLARGED - ELEC, DATA & FLOORFINISH PLAN A-416B UNIT INT. ELEVATIONS - KING STUDIO ENLARGED A-417 UNIT PLAN - KING 1-BEDROOM A-417A UNIT PLAN - KING 1-BEDROOM - ELEC, DATA & FLOOR FINISHPLAN A-417B UNIT INT. ELEVATIONS - KING 1-BEDROOM A-418 UNIT PLAN - KING 1-BEDROOM ADA MOBILITY A-418A UNIT PLAN - KING 1-BEDROOM ADA - ELEC, DATA & FLOORFINISH PLAN A-418B UNIT INT. ELEVATIONS - KING 1-BR ADA MOBILITY A-419 UNIT PLAN - KING 1-BEDROOM ENLARGED A-419A UNIT PLAN - KING 1-BEDROOM ENLARGED - ELEC, DATA &FLOOR FINISH PLAN A-419B UNIT INT. ELEVATIONS - KING 1-BEDROOM ENLARGED A-420 UNIT PLAN - DOUBLE QUEEN STUDIO A-420A UNIT PLAN - DOUBLE QUEEN STUDIO - ELEC, DATA & FLOORFINISH PLAN A-420B UNIT INT. ELEVATION - DOUBLE QUEEN STUDIO A-421 UNIT PLAN - DOUBLE QUEEN STUDIO ADA MOBILITY A-421A UNIT PLAN - DOUBLE QUEEN STUDIO ADA- ELEC, DATA &FLOOR FINISH PLAN A-421B UNIT INT. ELEVATION - DOUBLE QUEEN STUDIO ADA MOBILITY A-422 UNIT PLAN - DOUBLE QUEEN STUDIO ENLARGED A-422A UNIT PLAN - DOUBLE QUEEN STUDIO ENLARGED - ELEC, DATA& FLOOR FINISH PLAN A-422B UNIT INT. ELEVATION - DOUBLE QUEEN STUDIO ENLARGED A-423 UNIT BATH - EFFICIENCY BATH PLANS AND INTERIORELEVATIONS A-424 UNIT BATH -ACCESSIBLE BATH PLANS AND INTERIORELEVATIONS A-425 UNIT BATH - STUDIO BATH PLANS AND INTERIOR ELEVATIONS A-426 RESTROOM ACCESSORY AND MOUNTING DETAILS PROJECT TEAMSHEET INDEX OWNER GL8 MIRABEAU POINT, LLC10909 EAST PIERCE LANESPOKANE, WA 99206(509) 919-0901 ARCHITECT FSC ARCHITECTS737 BISHOP STREETSUITE 1860HONOLULU, HI 96813(808) 352-5299 CONTRACTOR BAKER CONSTRUCTION2711 EAST SPRAGUE AVENUESPOKANE, WA 99202(509) 535-3668 CIVIL ENGINEER SIMPSON ENGINEERS909 NORTH ARGONNE ROADSPOKANE VALLEY, WA 99212(509) 926-1322 LANDSCAPE ARCHITECT SPVV LANDSCAPE ARCHITECTS1908 WEST NORTHWEST BOULEVARDSUITE ASPOKANE, WA 99205(509) 325-0511 STRUCTURAL ENGINEER LSB CONSULTING ENGINEERS523 EAST THIRD AVENUESPOKANE, WA 99202(509) 323-9292 MECHANICAL/PLUMBING ENGINEER COFFMAN ENGINEERS, INC.10 NORTH POST STREETSUITE 500SPOKANE, WA 99223(509) 328-6169 POOL DESIGNER SELECT DESIGN BUILD CONSTRUCTION4810 POINT FOSDICK DRIVESUITE 117GIG HARBOR, WA 98335(253) 777-6109 FIRE SPRINKLER DESIGNER INLAND EMPIRE FIRE PROTECTION3832 E. BOONE AVESPOKANE, WA, 99202(509) 534-1097 KITCHEN DESIGNER SPOKANE RESTAURANT EQUIPMENT1750 EAST TRENT AVENUESPOKANE, WA 99202(509) 868-2713 ELEVATOR DESIGNER OTIS ELEVATORS510 EAST NORTH FOOTHILLS DRIVESPOKANE, WA 99207(509) 951-2280 LOW VOLTAGE DESIGNER FIREPOWER, INC.10220 NORTH NEVADA STREETSUITE 80SPOKANE, WA 99218(888) 706-3473 A-431 ENLARGED PLAN - LOBBY, MEETING ROOM, RESTROOMS &STORAGE A-432 INTERIOR ELEVATIONS - LOBBY A-432A INTERIOR ELEVATIONS - LOBBY, VESTIBULE A-433 INTERIOR ELEVATIONS - MTG. ROOM & STO, ELEVATORLOBBY, GUEST STO. A-434 ENLARGED PLAN & INTERIOR ELEVATIONS - OFFICES ANDFOOD PREP A-434A INTERIOR ELEVATIONS - FOOD PREP A-435 ENLARGED PLAN AND INTERIOR ELEVATIONS - EMPLOYEE,FITNESS & LAUNDRY LOUNGE A-436 INTERIOR ELEVATIONS - EMPLOYEE RESTROOM A-437 INTERIOR ELEVATIONS - PUBLIC RESTROOM PLAN ANDINTERIOR ELEVATIONS A-438 INTERIOR ELEVATIONS - PUBLIC RESTROOM RCP ANDINTERIOR ELEVATIONS A-442 ENLARGED BOH PLAN & INTERIOR ELEVATIONS A-443 BOH INTERIOR ELEVATIONS A-444 ENLARGED PLAN - POOL, SPLASH PAD, RESTROOM & MEPAND ELECTRICAL A-445 ENLARGED FFE PLAN -POOL, SPLASH PAD, RESTROOM & MEPAND ELECTRICAL A-446 INTERIOR ELEVATIONS - POOL & SPLASH PAD A-447 ENLARGED POOL RESTROOM DRAWINGS A-448 ENLARGED PLAN & INTERIOR ELEVATIONS - OFFICE /STORAGE / PBX ROOM A-450 ENLARGED PLAN & INTERIOR ELEVATIONS - GUESTCORRIDOR EAST WING A-451 ENLARGED PLAN & INTERIOR ELEVATIONS - GUESTCORRIDOR EAST WING A-452 ENLARGED PLAN & INTERIOR ELEVATIONS - GUESTCORRIDOR WEST WING A-453 ENLARGED PLAN & INTERIOR ELEVATIONS - TYP. LVL. GUESTCORRIDOR WEST WING A-454 INTERIOR ELEVATIONS - TYP. LVL. GUEST CORRIDOR WESTWING A-501 STAIR 1 DETAILS A-502 STAIR 2 DETAILS A-503 ELEVATOR DETAILS A-504 ELEVATOR LOBBY DETAILS A-505 CANOPY DETAILS A-506 CANOPY DETAILS A-507 ROOF DETAILS A-508 ROOF DETAILS A-509 EIFS DETAILS A-510 TRANSITION, THRESHOLD, & CEILING DETAILS A-511 ACCESSIBLE DETAILS A-512 FIRE PENETRATION DETAILS A-513 EXTERIOR WALL TYPES - EIFS A-514 EXTERIOR WALL TYPES - STONE VENEER A-515 EXTERIOR WALL TYPES A-516 PARTITION TYPES A-517 PARTITION TYPES A-518 CEILING TYPES A-519 DETAILS A-520 CEILING- SUSPENDED GWB TYP. DETAILS A-521 CEILING- SUSPENDED GWB TYP. DETAILS A-601 WINDOW TYPES AND SCHEDULE A-602 DOOR TYPES AND SCHEDULE A-603 ROOM FINISH SCHEDULE A-604 FINISH SCHEDULE A-701 MILLWORK DETAILS- LOBBY TAP WALL A-702 MILLWORK DETAILS- LOBBY AND GUEST STORAGE A-703 MILLWORK DETAILS- FITNESS AND LOBBY A-704 MILLWORK DETAILS- LOBBY AND PUBLIC A-705 MILLWORK DETAILS- EMPLOYEE AND LAUNDRY LOUNGE A-706 MILLWORK DETAILS- RECEPTION DESK PLAN AND OUTSIDEELEVATIONS A-707 MILLWORK DETAILS- RECEPTION DESK SECTIONS ANDDETAILS A-708 MILLWORK DETAILS- GUESTROOM KITCHENS A-709 MILLWORK DETAILS- ACCESSIBLE GUESTROOM KITCHENS A-710 MILLWORK DETAILS- MODIFIED FURNITURE MECHANICAL M-001 GENERAL MECHANICAL NOTES AND LEGENDS M-100 GROUND FLOOR ZONE PLAN M-101 GROUND FLOOR MECHANICAL PLAN M-102 2ND FLOOR MECHANICAL PLAN M-103 3RD FLOOR MECHANICAL PLAN M-104 4TH FLOOR MECHANICAL PLAN M-105 5TH FLOOR MECHANICAL PLAN M-106 MECHANICAL ROOF PLAN M-401 ENLARGED MECHANICAL PLANS M-402 ENLARGED MECHANICAL PLANS M-601 MECHANICAL CONTROL DIAGRAMS M-701 MECHANICAL SCHEDULES M-702 MECHANICAL SCHEDULES M-703 MECHANICAL SCHEDULES PLUMBING P-100 UNDERFLOOR PLUMBING PLAN P-101 GROUND FLOOR PLUMBING PLAN P-102 2ND FLOOR PLUMBING PLAN P-103 3RD FLOOR PLAUMBING PLAN P-104 4TH FLOOR PLUMBING PLAN P-105 5TH FLOOR PLUMBING PLAN P-106 PLUMBING ROOF PLAN P-111 GROUND FLOOR REFRIGERANT AND CONDENSATE PIPINGPLAN P-112 2ND FLOOR REFRIGERANT AND CONDENSATE PIPING PLAN P-113 3RD FLOOR REFRIGERANT AND CONDENSATE PIPING PLAN P-114 4TH FLOOR REFRIGERANT AND CONDENSATE PIPING PLAN P-115 5TH FLOOR REFRIGERANT AND CONDENSATE PIPING PLAN P-401 ENLARGED PLUMBING PLANS P-402 ENLARGED PLUMBING PLANS P-403 ENLARGED WATER HEATER ROOM P-501 PLUMBING DETAILS P-502 PLUMBING DETAILS P-601 WASTE AND VENT RISER DIAGRAM P-602 WASTE AND VENT RISER DIAGRAM P-603 DOMESTIC WATER RISER DIAGRAM P-604 DOMESTIC WATER RISER DIAGRAM P-605 CONDENSATE DRAIN RISER DIAGRAM P-701 PLUMBING SCHEDULES P-702 PLUMBING DETAILS ELECTRICAL E-001 ELECTRICAL SYMBOLS AND ABBREVIATIONS E-002 EQUIPMENT SCHEDULES E-003 EQUIPMENT SCHEDULES E-004 LUMINAIRE SCHEDULES E-005 LUMINAIRE SCHEDULES E-101 ELECTRICAL SITE PLAN E-102 ELECTRICAL SITE DETAILS E-103 ELECTRICAL SITE DETAILS E-104 STORAGE SHED ENLARGED ELECTRICAL PLAN E-201A FIRST FLOOR LIGHTING PLAN - AREA A E-201B FIRST FLOOR LIGHTING PLAN - AREA B E-202A SECOND FLOOR LIGHTING PLAN - AREA A E-202B SECOND FLOOR LIGHTING PLAN - AREA B E-203A THIRD FLOOR LIGHTING PLAN - AREA A E-203B THIRD FLOOR LIGHTING PLAN - AREA B E-204A FOURTH FLOOR LIGHTING PLAN - AREA A E-204B FOURTH FLOOR LIGHTING PLAN - AREA B E-205A FIFTH FLOOR LIGHTING PLAN - AREA A E-205B FIFTH FLOOR LIGHTING PLAN - AREA B E-301A FIRST FLOOR ELECTRICAL PLAN - AREA A E-301B FIRST FLOOR ELECTRICAL PLAN - AREA B E-302A SECOND FLOOR ELECTRICAL PLAN - AREA A E-302B SECOND FLOOR ELECTRICAL PLAN - AREA B E-303A THIRD FLOOR ELECTRICAL PLAN - AREA A E-303B THIRD FLOOR ELECTRICAL PLAN - AREA B E-304A FOURTH FLOOR ELECTRICAL PLAN - AREA A E-304B FOURTH FLOOR ELECTRICAL PLAN - AREA B E-305A FIFTH FLOOR ELECTRICAL PLAN - AREA A E-305B FIFTH FLOOR ELECTRICAL PLAN - AREA B E-306 OVERALL ELECTRICAL ROOF PLAN E-501 ENLARGED ELECTRICAL PLANS E-502 ENLARGED ELECTRICAL PLANS E-503 ENLARGED ELECTRICAL PLANS E-504 ENLARGED POOL PHOTOMETRIC PLAN E-601 POWER ONE-LINE DIAGRAM E-602 POWER ONE-LINE DIAGRAM E-603 PANEL SCHEDULES E-604 PANEL SCHEDULES E-605 PANEL SCHEDULES E-606 PANEL SCHEDULES E-607 PANEL SCHEDULES E-608 PANEL SCHEDULES E-609 PANEL SCHEDULES E-610 PANEL SCHEDULES E-611 PANEL SCHEDULES E-612 PANEL SCHEDULES E-701 ELECTRICAL DETAILS E-702 ELECTRICAL DETAILS EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV REVISION SCHEDULE # DESCRIPTION DATE 2 ADDENDUM 2 6/21/2024 2 A-1011 SIM A101 A NameElevation 0'4' 8'16' SCALE: 1/8" = 1'-0" Room name 101 150 SF 1 A-101 SIM /1 A101 1 View Name1/8" = 1'-0"A101 SHEET REFERENCE VIEW REFERENCE CENTER LINE ELEVATION TAG GRID LINE SHEET REFERENCE VIEW REFERENCE SECTION TAG CL-A88'-88" VIEW TITLE GRAPHIC SCALE VIEW REFERENCE SCALE SHEET REFERENCE NORTH ARROW CEILING/SOFFIT/ROOF TAG CALLOUT VIEW REFERENCE SHEET REFERENCE REFERENCE AREA SHEET REFERENCE VIEW REFERENCE SHEET REFERENCE LEVEL TAG LEVEL ELEVATION LEVEL NAME ROOM TAG ROOM AREA ROOM NAME TYPE DOOR TAG WINDOW / GLASS TAG DOOR MARK P1 WINDOW TYPE WALL / PARTITION TAG WALL TYPEP- PARTITIONX- EXTERIOR 1 REVISION TAG REVISION CLOUD REVISION TAG 1 A-101 SIM WALL SECTION/DETAIL SECTION SHEET REFERENCE VIEW REFERENCE 1 Ref 1Ref 1 Ref1 Ref CURTAIN WALL TAG FLOOR TAG MATERIAL TAG KEYNOTE TAG 37 1i 1i HEIGHT A.F.F. Length Time sec PATH OF TRAVEL TAG FURNITURE/LIGHT/CASEWORK TAG 1i XXX-## ?XX-### PATH OF TRAVEL INFORMATIONCURTAIN WALL MARK KEYNOTE ITEM MARKMATERIAL TYPE FLOOR TYPE GYPSUM WALL BOARD CONCRETE ASPHALT WOOD SLATS RIGID INSULATION BATT INSULATION STONE VENEER EARTH LUMBER ANCHOR BOLT AIR CONDITIONINGACOUSTICAL TILEACOUSTICAL ABOVE FINISH FLOORALUMINUM ANODIZED ACCESS PANELAPPROXIMATEARCHITECTURAL BOARDBUILDINGBLOCKING BOTTOM CABINETCONTROL JOINT CEILING CLEAR CONC. MASONRY UNITCARBON MONOXIDE (DETECTOR)CLEAN OUT COLUMN CONCRETE CONTINUOUS CEMENT PLASTERCARPET CERAMIC TILECOURTYARD COLD WATER DETAILDRINKING FOUNTAIN DISPENSER DOOR DOOR OPENING DOWN DRAWING EASTEACH NO(S). OR # EXPANSION JOINTELECTRICAL ELEVATIONEQUAL EQUIPMENT EACH WAYELECTRIC WATER COOLEREXHAUST EXISTING EXPANSIONEXTERIOR FLOOR DRAIN FIRE EXTINGUISHER FIRE EXTINGUISHER CABINETFACTORY FINISH FINISH FIRE HOSE CABINET FLOORFACE OF CONCRETE FACE OF FINISH FACE OF MASONRY FACE OF STUDS FOOT OR FEET GAUGE GALVANIZED GALVANIZED IRON GLASS, GLAZING GYPSUM WALL BOARD GYPSUM HOSE BIBBHOLLOW CORE HANDICAPPED HARDWOODHARDWARE HOLLOW METALHOUR HEIGHT HEATING,VENTILATION& AIR CONDITIONING HOT WATER INSIDE DIAMETER INCLUDING INSULATIONINTERIOR JOINT KITCHEN LAMINATELAVATORY LIGHT GAUGE STEEL FRAMINGLIGHT MACHINE MATERIAL MAXIMUMMEMBRANE A.B. AC ACT ACOUS. A.F.F. ALUM, AL ANOD. A.P.APPROX. ARCH. BD.BLDG. BLKG. BOT. CAB.C.J. CLG. CLR. CMUCO C.O. COL. CONC. CONT.C.P.CPT.C.T.CTYDCW DET.D.F.DISP.DR.D.O.DN.DWG.E.EA.E.J.ELEC.ELEV.EQ.EQUIP.E.W.E.W.C.EXH.EXIST.(E) EXP. EXT.F.D.F.E.F.E.C.F.F.FIN.F.H.C.FLR.F.O.C.F.O.F. F.O.M. F.O.S. FT. GA.GALV.G.I.GL.GWB GYP.H.B.H.C.HCHDWD.HDWR.H.M.HR.HGT.H.V.A.C. HW I.D.INCL.INSUL. INT JT.KIT.LAM.LAV.LGSF.LT.MACH,MATL. MAX.MEMB. METALMINIMUM MISCELLANEOUS NORTH NOT IN CONTRACT NUMBER(S)NOT TO SCALENON RATEDOBSCUREON CENTER OVERFLOW DRAINOWNER FURNISHCONTRACTOR INSTALLOWNER FURNISH OWNER INSTALL OPPOSITE PAINT PLANTER DRAIN PLATE PLASTIC LAMINATE PLASTER PLYWOOD PANEL PAPER TOWEL DISPENSER PAPER TOWEL RECEPTACLE QUARRY TILERADIUS RESILIENT BASE REFERENCE REINFORCING REQUIRED ROOM SOUTHSOLID CORE SCHEDULE SMOKE DETECTORSECTION SHEET SHEATHING SIMILAR SLOPE SLIDING SPECIFICATIONSQUARE STAINLESS STEEL SERVICE SINK STONE STANDARD STEEL STORAGE STRUCTURAL SUSPENDED SYMMETRICAL SYSTEM TREAD TELEPHONE TEMPERED THICK TOP OF FINISHED FLOORTOP OF PARAPET TOP OF STRUCTURAL SLABTOILET PAPER DISPENSERTOILET PAPER HOLDER TOP OF STEEL TYPICAL UNLESS OTHERWISE NOTEDURINAL VINYL COMPOSITION TILE VERTICAL VESTIBULE VENT THRU ROOF WESTWITH WALL COVERING WATER CLOSET WOOD WINDOW WATER HEATER WATERPROOF MEMBRANE SYSTEM AND AT NUMBER ANGLE CENTER LINE PLUS OR MINUSDIAMETER OR ROUND MET. MIN.MISC.N.N.I.C.N.T.S.N.R.OBSC.O.C.ODO.F.C.I. O.F.O.I.OPP.PTP.D.PL.PLAM.PLAS.PLYWD.PNL.P.T.D. P.T.R.Q.T.PNL.R.B. REF.REINF.REQ.RMS..S.A.SCHED.SDSECT.SHT.SHTG. SIM.SL.SLDG. SPECSQ.S.S.S/S ST.STD.STL.STO. STRUC. SUSP. SYM. SYS.T. TEL.TEMP.THK.T.F.F. T.O.P. T.S.S. T.P.D. T.P.H.T.S.TYP. U.O.N.UR.V.C.T.VERT. VEST. V.T.R. W.W/ W.C.WC WD.WDW.W.H.WMS &@#∠℄±⌀ MATCH LINE SETBACK LINE PROPERTY LINE REFERENCE WATERPROOFING NOT USED ADHESIVE DEMOLISHED CENTER LINE BEYOND LEVEL OVERHEAD GRID HIDDEN 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216PROJECT INFORMATION G-002 FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216PROJECT INFORMATION G-002 FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 ZONING DATA - HOTELBUILDING CODE DATA - HOTEL APPLICABLE CODES MUNICIPAL AMENDMENTS:SPOKANE VALLEY MUNICIPAL CODE, TITLE 24(SVMC) BUILDING CODE: 2018 INTERNATIONAL BUILDING CODEAS AMENDED BY CHAPTERS 19.27 AND 19.27A RCWCHAPTER 51-50 WAC (IBC 2018) ENERGY CODE: 2018 WASHINGTON STATE ENERGY CODEAS AMENDED BY CHAPTERS 51-11C AND 51-11R WAC(WSEC 2018) MECHANICAL CODE: 2018 INTERNATIONAL MECHANICAL CODE(IMC 2018)2018 INTERNATIONAL FUEL GAS CODE(IFGC 2018)NFPA 58 AND NFPA 54AS AMENDED BY CHAPTER 51-52 WAC FIRE CODE:2018 INTERNATIONAL FIRE CODEAS AMENDED BY CHAPTERS 19.27 AND 34.05 RCWAND CHAPTER 51-54 WAC(IFC 2018) PLUMBING CODE:2018 UNIFORM PLUMBING CODE AS AMENDED BY CHAPTER 51-56 WAC(UPC 2018) ELECTRICAL CODE:2020 NATIONAL ELECTRICAL CODE (NFPA 70) ACCESSIBILITY:2010 AMERICANS WITH DISABILITIES ACT STANDARD FOR ACCESSIBLE DESIGN, THE FAIR HOUSING ACT DESIGN MANUAL AND 2009 ANSI A117.1.(ADA 2010) CODE ANALYSIS CONSTRUCTION TYPE:III-B (S) SPRINKLERED:FULLY SPRINKLERED PER SECTION 903.3.1.1 OCCUPANCY:GROUND FLOORUPPER FLOORMAIN OCCUPANCIES:A-2, A-4, F-1, R-1, S-1 R-1ACCESSORY OCCUPANCIES: A-3, BS-1 CLIMATE ZONE:5B (DRY COOL) ALLOWABLE AREA/HEIGHT/STORIESGROUND FLOOR (MIXED A-2, A-4, F-1, R-1, S-1) SPRINKLER SYSTEM:13/S/SMALLOWABLE TOTAL FLOOR AREA/STORY: 25,500 SFALLOWABLE NUMBER OF STORIES:3 STORIESALLOWABLE HEIGHT:75 FEET PROPOSED FLOOR AREA/STORY:18,524 SFPROPOSED NUMBER OF STORIESWITH A-2, A-4, F-1, R-1, S-1:GROUND FLOOR UPPER FLOORS (R-1) SPRINKLER SYSTEM:13/S/SMALLOWABLE TOTAL FLOOR AREA/STORY: 48,000 SFALLOWABLE NUMBER OF STORIES:5 STORIESALLOWABLE HEIGHT:75 FEET PROPOSED FLOOR AREA/STORY:18,667 SFPROPOSED NUMBER OF STORIES:2ND-5TH FLOORSPROPOSED BUILDING HEIGHT:71' - 2" TOTAL GROSS BUILDING AREA:93,192 SF AVAILABLE EXITS:SEE CODE PLANS FIRE RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS BUILDING ELEMENTFIRE RESISTANCE RATINGPRIMARY STRUCTURAL FRAME0 HOURSBEARING WALLS*EXTERIOR2 HOURS (INSIDE EXP. PER 705.5)*INTERIOR0 HOURSNONBEARING WALLS AND PARTITION*EXTERIORSEE TABLE 602*INTERIOR0 HOURSFLOOR CONSTRUCTION0 HOURSROOF CONSTRUCTION0 HOURSSHAFTS2 HOURSELEVATOR ENCLOSURE2 HOURSSTAIR ENCLOSURE2 HOURSLINEN CHUTE, DRYER ROOMAND DISCHARGE ROOM2 HOURSBALCONIES/PROJECTIONS0 HOURS (PER 705.2.3.1, E.3&4)OPENINGS IN EXTERIOR WALLS0 HOURS (PER 602.1, T705.8)CORRIDOR WALLS1/2 HOUR (PER 708.4, E.1)DWELLING/SLEEPING UNIT SEPARATION 1/2 HOUR (PER 708.4, E.2)SMOKE BARRIER1 HOUR (PER T716.1(2)) TABLE 602: NON-BEARING EXTERIOR WALLS AND PARTITIONSFIRE SEPARATION DISTANCE CONST. TYPE OCC. F-1 & S-1 OCC. A & RX < 5'III-B2 HOURS 1 HOURX > OR = 5' AND < 10'III-B1 HOUR 1 HOURX > OR = 10' AND < 30' III-B1 HOUR 1 HOURX > OR = 30'III-B0 HOURS 0 HOURS FIRE PROTECTION SYSTEMSSEE FIRE PROTECTION PLANS AND SPECIFICATIONS FOR INFORMATION REGARDING AUTOMATIC SPRINKLER SYSTEM DESIGN AND INSTALLATION. SEE ELECTRICAL DRAWINGS FOR INFORMATION REGARDING FIRE ALARM AND DETECTION SYSTEM DESIGN AND INSTALLATION. APPLICABLE ZONING CODE SPOKANE VALLEY MUNICIPAL CODE, TITLES 19, 22 AND ZONING MAP ZONING CODE SUMMARY PROJECT LOCATION: NORTH OF EAST CARLISLE AVENUE AND EAST OFNORTH MIRABEAU PARKWAY PROJECT ADDRESS:13515 E CARLISLE AVENUESPOKANE VALLEY, WA 99216 PARCEL NUMBER:45101.0401 ZONING:MU (MIXED USE) IN SEPA INFILL ADJACENT ZONING:POS, MU PROPOSED USE:HOTEL LOT AREA:3.26 AC (142,453 SF) FLOOD ZONE:ZONE X PARKING/LOADING REQUIRED PARKING: 132 ROOMS @ 1 SPACE PER HOTEL ROOM 132 SPACES16 STAFF @ 1 SPACE PER STAFF ON THE LARGEST SHIFT16 SPACESTOTAL REQUIRED: 148 SPACES PROPOSED PARKING: 116 STANDARD SPACES @ 9' - 0" X 18' - 0"28 COMPACT SPACES @ 8' - 0" X 18' - 0"5 STANDARD ACCESSIBLE SPACES @9' - 0" X 18' - 0" + 5' - 0" ACCESS AISLE1 VAN ACCESSIBLE SPACE @11' - 0" X 18' - 0" + 5' - 0" ACCESS AISLETOTAL PROVIDED: 150 SPACES REQUIRED ELECTRIC VEHICLE INFRASTRUCTURE:149 SPACES @ 10% EV READYTOTAL REQUIRED: 15 SPACES WIRED FOR 208/240V, 40 AMP CHARGING PROVIDED ELECTRICL VEHICLE INFRASTRUCTURE:16 SPACES (2/UNIT), INCLUDING 1 ACCESSIBLE SPACE WIRED FOR 208/240V, 40 AMP CHARGING LOADING REQUIRED/PROVIDED:1 LOADING SPACE @ 12' - 0" X 30' - 0" BICYCLE PARKING REQUIRED:3 BICYCLE RACKS FOR 2+ BICYCLES FOR 100-500 SPACES BICYCLE PARKING PROVIDED:4 BICYCLE RACKS FOR 2 BICYCLES AT FRONT ENTRANCE IMPERVIOUS SURFACES TOTAL ROOF AREA:22,472 SFTOTAL ASPHALT/PAVING/CONCRETE/CURBS: 75,469 SF PERCENT OF LOT COVERED BY BUILDING:15.78% TOTAL IMPERVIOUS AREA COVERAGE:65.8% (93,492 SF) ENERGY CODE BUILDING ELEMENTMINIMUM INSULATION VALUEEXTERIOR WALLSR-20 STD + 3.8 CIBELOW-GRADE WALL R-25 OR R-20 STD + 3.8 CCANTILEVERED FLOORS R-30UNHEATED SLABR-10 FOR 24" BELOWROOF R-38 CIROOF (TAPERED INSUL.) R-38 EQUIVALENT PER WSEC TABLE A102.2.6(1) AND (2)MINIMUM R-VALUE AT VALLEY: R-22.5 (4" INSULATION)MAXIMUM CODE-ALLOWED R-VALUE: R-60 ANNOTATION LEGEND ABBREVIATION LEGEND LINE TYPES CODE ANALYSIS CONSTRUCTION TYPE:V-B (NS) SPRINKLERED:NO OCCUPANCY:S-1 PROPOSED USE:STORAGE CLIMATE ZONE:5B (DRY COOL) ALLOWABLE AREA/HEIGHT/STORIESSPRINKLER SYSTEM:NSALLOWABLE TOTAL FLOOR AREA/STORY: 9,000 SFALLOWABLE NUMBER OF STORIES:1 STORYALLOWABLE HEIGHT:40 FEET PROPOSED FLOOR AREA/STORY:253 SFPROPOSED NUMBER OF STORIES1 STORY TOTAL GROSS COVERED BUILDING AREA:253 SF QUALIFIES AS A LOW-ENERGY BUILDING: C402.1.1 (1): <1 WATT/SF ENERGY USAGE FIRE RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS BUILDING ELEMENTFIRE RESISTANCE RATINGPRIMARY STRUCTURAL FRAME0 HOURSBEARING WALLS*EXTERIOR0 HOURS*INTERIOR0 HOURSNONBEARING WALLS AND PARTITION*EXTERIORSEE TABLE 602*INTERIOR0 HOURSFLOOR CONSTRUCTION0 HOURSROOF CONSTRUCTION0 HOURS FIRE-RESISTANCE RATING REQUIREMENTS FOR EXTERIOR WALLS (TABLE 602):REQUIREMENTS BELOW SHALL BE FOLLOWED FOR ALL NEW CONSTRUCTION FIRE SEPARATION DISTANCE CONST. TYPE OCC. S-1X < 5'V-B2 HOURSX > OR = 5' AND < 10'V-B1 HOURX > OR = 10' AND < 30' V-B0 HOURS X > OR = 30'V-B0 HOURS FIRE PROTECTION SYSTEMSSEE ELECTRICAL DRAWINGS FOR INFORMATION REGARDING FIRE ALARM AND DETECTION SYSTEM DESIGN AND INSTALLATION. BUILDING & ZONING CODE DATA - STORAGE/TRASH ENCLOSUREPLUMBING FIXTURE CALCS ••••••• POOL & SPLASH PADKITCHENFIRE SPRINKLERSFIRE ALARMELEVATORSSOLARNON-RESIDENTIAL ENERGY CODE (ENGAGEMENT LETTER SUBMITTED)N PINES ROADN PINES ROADFREEWAYFREEWAY E TRENTE TRENTAVEAVE SP O K A N E S P O K A N E RIV E R R I V E R SP O K A N E S P O K A N E RIV E R R I V E R E. BROADWAY AVE. SPOKANE VALLEYSPOKANE VALLEY MALLMALL E. MANSFIELD AVE. E. INDIANA AVE. E MISSION AVE. E BROADWAY AVE. E. CARLISLE AVE.N. M IRABEAU PKWY . VICINITY MAPNTS PROJECT LOCATION13515 E. CARLISLE AVE. MATERIAL LEGEND PROVIDED4.54.5 3.5 3.5 2 TOTAL REQUIRED ROUNDED UP35 1 2 1 TOTAL REQUIRED2.234.035 0.57 1.65 0.772 9 OCC/GENDER0.090.09 0.09 0.018 S-1: STORAGE AND SERVICE1 WC PER 100 PEOPLE 1 LAV. PER 100 PEOPLE 1 D.F. PER 1,000 PEOPLE 3 OCC./GENDER0.120.12 0.075 0.06 B: BUSINESS1 WC PER 25 PEOPLE 1 LAV. PER 40 PEOPLE 1 D.F. PER 100 PEOPLE 58 OCC./GENDER0.7731.45 0.29 0.387 0.116 A4: POOL1 WC PER 75 PEOPLE 1 WC PER 40 PEOPLE 1 LAV. PER 200 PEOPLE 1 LAV. PER 150 PEOPLE 1 D.F. PER 1,000 PEOPLE 9 OCC./GENDER0.120.225 0.045 0.06 0.018 A3: FITNESS1 WC PER 75 PEOPLE 1 WC PER 40 PEOPLE 1 LAV. PER 200 PEOPLE 1 LAV. PER 150 PEOPLE 1 D.F. PER 1,000 PEOPLE 140 OCC./GENDER1.122.15 0.7 0.56 A2: PUBLIC SPACES1 WC PER 125 PEOPLE 1 WC PER 65 PEOPLE 1 LAV. PER 200 PEOPLE 1 D.F. PER 500 PEOPLE MENWOMEN MEN WOMEN WATER CLOSETS LAVATORY DRINKING FOUNTAIN DEFERRED SUBMITTALS NOTE: PROVIDED TOILET STALLS INCLUDE MEN'S AND WOMEN'S RESTROOMS AS WELL AS 1 UNISEX PUBLIC RESTROOM AND TWO DEDICATED STALLS FOR STAFF LOCATED IN THE EMPLOYEE BREAKROOM. ALL HOTEL GUESTS ALSO HAVE ACCESS TO BATHROOMS IN THEIR GUESTROOMS. TWO BOTTLE FILLERS AND AN ICE MACHINE WITH A WATER SPIGOT ARE PROVIDED FOR GUEST USE, ONE IN THE LOBBY, ONE IN THE ICE/WATER ROOM AND ONE IN THE FITNESS ROOM. EACH WILL HAVE CUPS PROVIDED FOR GUEST USE IF THEY DO NOT HAVE A WATER BOTTLE. ENGINEERED GRADING PERMIT:EGR-2024-0041NOTE: ALL CIVIL DRAWINGS SUBMITTED AS PART OF THIS PERMIT, NO CIVIL DRAWINGS TO BE SUBMITTED AS PART OF BLD-2024-0696 STORAGE SHED AND TRASH ENCLOSURE BUILDING PERMIT: BLD-2024-0697NOTE: ALL DRAWINGS BEING SUBMITTED THROUGH PERMIT BLD-2024-0696 ASSOCIATED PERMITS EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV REVISION SCHEDULE # DESCRIPTION DATE 2 ADDENDUM 2 6/21/2024 REVISION SCHEDULE # DESCRIPTION DATE 2 ADDENDUM 2 6/21/2024 2 BAL. CONNECTING K1B: ENL.SHOWER BAL. CONNECTING K1B: ENL.SHOWER BAL. CONNECTING K1B: ADAADA TUB BAL. CONNECTING K1B: ENL.SHOWER BAL. CONNECTING K1BSHOWER BAL. CONNECTING K1BSHOWER BAL. CONNECTING K1BSHOWER BAL. CONNECTING K1BSHOWER 5TH FLOOR 4TH FLOOR 3RD FLOOR 2ND FLOOR 1ST FLOOR X01X02X03X04X05X06X07X08X09X10X11X12X13X14X15X16X18X19X20X21X22 CONNECTING ES: ADAADA TUB CONNECTING ES: ADAR-I SHWR CONNECTING ES: ENL.SHOWER CONNECTING ES: ENL.SHOWER CONNECTING KSSHOWER CONNECTING KSSHOWER CONNECTING KSSHOWER CONNECTING KSSHOWER CONNECTING ESSHOWER CONNECTING ESSHOWER ESSHOWER CONNECTING ESSHOWER BOHPUBLICSTAIR STAIR STAIR STAIR STAIR CONNECTING ESSHOWER CONNECTING ESSHOWER CONNECTING ESSHOWER BOH BOH CONNECTING ESSHOWER CONNECTING ESSHOWER CONNECTING ESSHOWER CONNECTING ESSHOWER BOH BOH BOH BOH CONNECTING DQSSHOWER CONNECTING DQSSHOWER CONNECTING DQSSHOWER CONNECTING DQSSHOWER ELEV. ELEV. ELEV. ELEV. ELEV. ELEV. ELEV. ELEV. ELEV. ELEV. CONNECTING DQS: ENL.SHOWER CONNECTING DQS: ENL.SHOWER CONNECTING DQS: ENL.SHOWER CONNECTING DQS: ADAADA TUB PUBLICPUBLIC CONNECTING KSSHOWER CONNECTING KSSHOWER CONNECTING KSSHOWER CONNECTING KSSHOWER CORR. CORR. CORR. CORR. CORR. CONNECTING KSSHOWER CONNECTING KSSHOWER CONNECTING KSSHOWER CONNECTING KSSHOWER X17 ELEV. LOBBY ELEV. LOBBY ELEV. LOBBY ELEV. LOBBY ELEV. LOBBYPUBLIC CONNECTING KSSHOWER CONNECTING KSSHOWER CONNECTING KSSHOWER CONNECTING KSSHOWER BAL. CONNECTING KSSHOWER BAL. CONNECTING KSSHOWER BAL. CONNECTING KSSHOWER BAL. CONNECTING KSSHOWER CONNECTING KSSHOWER CONNECTING KSSHOWER CONNECTING KSSHOWER CONNECTING KSSHOWER BAL. CONNECTING KSSHOWER BAL. CONNECTING KSSHOWER BAL. CONNECTING KSSHOWER BAL. CONNECTING KSSHOWER CONNECTING DQSBATHTUB CONNECTING DQSBATHTUB CONNECTING DQSBATHTUB CONNECTING DQSBATHTUB X23 BAL. CONNECTING KSSHOWER BAL. CONNECTING KSSHOWER BAL. CONNECTING KSSHOWER BAL. CONNECTING KSSHOWER X24 CONNECTING DQSBATHTUB CONNECTING DQSBATHTUB CONNECTING DQSBATHTUB CONNECTING DQSBATHTUB X25 BAL. CONNECTING KSSHOWER BAL. CONNECTING KSSHOWER BAL. CONNECTING KSSHOWER BAL. CONNECTING KSSHOWER X26 CONNECTING KSSHOWER CONNECTING KSSHOWER CONNECTING KSSHOWER CONNECTING KSSHOWER X27 CONNECTING ESSHOWER CONNECTING ESSHOWER CONNECTING ESSHOWER CONNECTING ESSHOWER X28 CONNECTING ESSHOWER CONNECTING ESSHOWER CONNECTING ESSHOWER CONNECTING ESSHOWER X29 CONNECTING ESSHOWER CONNECTING ESSHOWER CONNECTING ESSHOWER CONNECTING ESSHOWER ESSHOWER X30 CONNECTING KSSHOWER CONNECTING KSSHOWER CONNECTING KSSHOWER CONNECTING KSSHOWER KSSHOWER X31 CONNECTING ESSHOWER CONNECTING ESSHOWER CONNECTING ESSHOWER CONNECTING ESSHOWER CONNECTING ESSHOWER X32 STAIR STAIR STAIR STAIR STAIR X33 CONNECTING ESSHOWER CONNECTING ESSHOWER CONNECTING ESSHOWER CONNECTING ESSHOWER CONNECTING ESSHOWER X34 ESSHOWER ESSHOWER ESSHOWER ESSHOWER ESSHOWER X35 BAL. CONNECTING DQSSHOWER BAL. CONNECTING DQSSHOWER BAL. CONNECTING DQSSHOWER BAL. CONNECTING DQSSHOWER BAL. CONNECTING DQSSHOWER X36 CONNECTING DQSBATHTUB CONNECTING DQSBATHTUB CONNECTING DQSBATHTUB CONNECTING DQSBATHTUB CONNECTING DQSBATHTUB X37 BAL. CONNECTING KSSHOWER BAL. CONNECTING KSSHOWER BAL. CONNECTING KSSHOWER BAL. CONNECTING KSSHOWER BAL. CONNECTING KSSHOWER X38 CONNECTING KS: ENL.SHOWER CONNECTING KS: ENL.SHOWER CONNECTING KS: ADAR-I SHWR CONNECTING KS: ADAADA TUB CONNECTING KS: ADAADA TUB ABBREVIATIONS / LEGEND: ADA TUB ACCESSIBLE BATHTUB BOH BACK-OF-HOUSE CORR. CORRIDOR DQS DOUBLE QUEEN SUITE ELEV. ELEVATOR ENL. ENLARGED ES EFFICIENCY SUITE BAL. KS KING STUDIO SUITE K1B KING 1-BEDROOM SUITE R-I SHWR ROLL-IN SHOWER COMMUNICATION FEATURE ROOM ACCESSIBLE MOBILITY ROOM BALCONY 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216BUILDINGDEVELOPMENTINFORMATION G-003 FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 ROOM COUNT BREAKDOWN VERTICAL ROOM CHART GENERAL NOTES BUILDING AREA PROGRAM TOTAL ROOMS BY FLOOR 9 30 31 31 31 132 KING ONE-BEDROOM SUITE - ACCESSIBLE (TUB)- - 1 - -1 KING ONE-BEDROOM SUITE - 2 1 2 2 7 6.06% DOUBLE QUEEN STUDIO SUITE - ACCESSIBLE (TUB)- - - - 1 1 DOUBLE QUEEN STUDIO SUITE 2 6 6 6 5 25 19.70% KING STUDIO SUITE - ACCESSIBLE (ROLL-IN)- - 1 - -1 KING STUDIO SUITE - ACCESSIBLE (TUB)1 1 - - -2 KING STUDIO SUITE 2 12 12 13 13 52 41.67% EFFICIENCY SUITE - ACCESSIBLE (ROLL-IN)- - - 1 -1 EFFICIENCY SUITE - ACCESSIBLE (TUB)- - - - 1 1 EFFICIENCY SUITE 4 9 10 9 9 41 32.58% ROOM TYPE 1STFLOOR 2NDFLOOR 3RDFLOOR 4THFLOOR 5THFLOOR # BYTYPE % BYTYPE 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. THE FOLLOWING GENERAL NOTES ARE APPLICABLE THROUGHOUT THESE CONSTRUCTION DRAWINGS. NOTHING SET FORTH IN THESE DRAWINGS SHALL RELEASE THE CONTRACTOR FROM ITS RESPONSIBILITY TO PROVIDE APPROPRIATE QUANTITIES, FIELD MEASUREMENTS, DIMENSIONAL STABILITY, INSTALLATION, ANCHORAGE, AND COORDINATION WITH ALL OTHER SUBCONTRACTORS AND TRADES, OR RELEASE THE CONTRACTOR OF RESPONSIBILITY TO IDENTIFY AND RESOLVE DEVIATIONS FROM THE REQUIREMENTS OF THESE DOCUMENTS OR RELEASE THE CONTRACTOR OF RESPONSIBILITY TO ALERT THE ARCHITECT TO ERRORS OR OMISSIONS CONTAINED THEREIN. THE CONTRACTOR SHALL WARRANT TO THE OWNER THAT ALL MATERIALS AND EQUIPMENT FURNISHED AND INSTALLED UNDER THIS CONTRACT SHALL BE NEW, UNLESS OTHERWISE SPECIFIED, AND THAT ALL WORK SHALL BE OF GOOD QUALITY, FREE FROM DEFECTS AND FAULTS, AND CONFORMS TO THE CONTRACT DOCUMENTS. THE CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS IN THE FIELD PRIOR TO COMMENCING WORK, AND SHALL REPORT ANY DISCREPANCIES BETWEEN DRAWINGS, SPECIFICATIONS AND FIELD CONDITIONS REQUIRING MODIFICATIONS TO THE ARCHITECT BEFORE PROCEEDING. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL COSTS ASSOCIATED WITH, OR CAUSED BY ITS FAILURE TO COMPLY WITH THIS REQUIREMENT. THE CONTRACTOR SHALL COORDINATE ALL WORK PROCEDURES WITH REQUIREMENTS OF LOCAL AUTHORITIES AND/OR BUILDING MANAGEMENT. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROTECTION OF ALL CONDITIONS AND MATERIALS WITHIN THE PROPOSED CONSTRUCTION AREA. THE CONTRACTOR SHALL DESIGN AND INSTALL REQUISITE SHORING AND BRACING FOR ALL STRUCTURAL OR REMOVAL TASKS. THE CONTRACTOR SHALL HAVE SOLE RESPONSIBILITY FOR ANY DAMAGE OR INJURIES CAUSED BY OR DURING THE EXECUTION OF THE WORK. THE CONTRACTOR SHALL COORDINATE AND WORK WITH ALL TRADES ON THE PROJECT NOT UNDER CONTRACT TO THE CONTRACTOR (I.E. TELEPHONE, DATA LINES, ETC.). ANY CHANGES OR DELAYS ARISING FROM CONFLICTS WITH SUCH TRADES SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR AT NO ADDITIONAL EXPENSE TO THE OWNER. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR, AND HAVE CONTROL OVER, ALL CONSTRUCTION MEANS, TECHNIQUES, SEQUENCES AND PROCEDURES AND FOR COORDINATING ALL PORTIONS OF THE WORK REQUIRED BY THE CONTRACT DOCUMENTS. THE DRAWINGS ARE THE GRAPHIC AND PICTORIAL PORTIONS OF THE CONTRACT DOCUMENTS, WHEREVER LOCATED AND WHENEVER ISSUED, SHOWING THE DESIGN, LOCATION AND DIMENSIONS OF THE WORK, GENERALLY INCLUDING PLANS, ELEVATIONS, SECTIONS, DETAILS, SCHEDULES AND DIAGRAMS. THE DRAWINGS WILL SHOW DIMENSIONS, POSITION AND KIND OF CONSTRUCTION. THE SPECIFICATIONS ARE THAT PORTION OF THE CONTRACT DOCUMENTS CONSISTING OF THE WRITTEN REQUIREMENTS FOR MATERIALS, EQUIPMENT, CONSTRUCTION SYSTEMS, STANDARDS AND WORKMANSHIP FOR THE WORK, AND PERFORMANCE OF RELATED SERVICES. THE SPECIFICATIONS WILL SHOW THE QUALITIES AND METHODS. ANY WORK CALLED FOR ON THE DRAWINGS AND MENTIONED IN THE SPECIFICATIONS OR VICE VERSA, SHALL BE PERFORMED AS THOUGH FULLY SET FORTH IN BOTH. WORK NOT PARTICULARLY DETAILED, MARKED OR SPECIFIED SHALL BE THE SAME AS SIMILAR PARTS THAT ARE DETAILED, MARKED OR SPECIFIED. CONTRACTOR TO VERIFY AND CHECK ALL DIMENSIONS AND DETAILS SHOWN ON THE DRAWINGS. SHOULD AN ERROR, DISCREPENCY OR AMBIGUITY APPEAR IN THE DRAWINGS OR SPECIFICATIONS OR IN THE WORK DONE BY OTHERS AFFECTING THIS WORK, THE CONTRACTOR SHALL NOTIFY THE CONSTRUCTION MANAGER AND ARCHITECT AT ONCE, THE CONSTRUCTION MANAGER AND ARCHITECT WILL THEN ISSUE WRITTEN INSTRUCTIONS AS TO PROCEDURE. IF THE CONTRACTOR PROCEEDS WITH THE WORK AS AFFECTED, WITHOUT INSTRUCTIONS FROM THE CONSTRUCTION MANAGER AND ARCHITECT, HE DOES SO AT HIS OWN RISK AND EXPENSE. THIS INCLUDES TYPOGRAPHICAL ERRORS ON THE DRAWINGS WHERE THEY OCCUR AND DOUBTFUL INTERPRETATIONS. FIGURED DIMENSIONS ON THE SCALED DRAWINGS AND THE LARGER SIZE DRAWINGS SHALL TYPICALLY GOVERN. WHERE ON ANY DRAWINGS A PORTION OF THE WORK IS DRAWN OUT AND THE REMAINDER IS INDICATED IN OUTLINE, THE DRAWN OUT PARTS SHALL APPLY TO ALL LIKE PORTIONS OF THE WORK. WHERE ORNAMENT OR OTHER DETAIL IS INDICATED BY STARTING ONLY, SUCH DETAIL SHALL BE CONTINUED THROUGHOUT THE COURSES OR PARTS IN WHICH IT OCCURS AND SHALL APPLY TO ALL OTHER SIMILAR PARTS IN THE WORK UNLESS OTHERWISE INDICATED. 14. 15. 16. 17. 18. 19. 20. 21. 22. 23. 24. 25. 26. 27. 28. DETAILS NOT SHOWN ARE SIMILAR IN CHARACTER TO THOSE THAT ARE. WHERE SPECIFICATIONS, DIMENSIONS, DETAILS OR DESIGN INTENT CANNOT BE DETERMINED, CONSULT THE ARCHITECT BEFORE PROCEEDING WITH WORK. FOR CONVENIENCE, THE SPECIFICATIONS AND DRAWINGS ARE ARRANGED IN SEVERAL DIVISIONS AND SECTIONS, BUT SUCH SEPARATIONS SHALL NOT BE CONSIDERED AS THE LIMITS OF THE WORK REQUIRED FOR ANY SUBCONTRACT OR TRADE. THE TERMS AND CONDITIONS OF SUCH LIMITATIONS ARE WHOLLY BETWEEN EACH CONTRACTOR AND HIS SUBCONTRACTORS. EACH CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL SUBCONTRACT ARRANGEMENTS OF WORK REGARDLESS OF THE LOCATION OF PROVISIONS IN THE SPECIFICATIONS. SCHEDULES OF WORK INCLUDED IN THESE GENERAL NOTES ARE GIVEN FOR CONVENIENCE ONLY AND SHALL NOT BE CONSIDERED AS A COMPREHENSIVE LIST OF ITEMS NECESSARY TO COMPLETE THE WORK. WHERE DEVICES OR ITEMS OR PARTS THEREOF ARE REFERRED TO IN THE SINGULAR, IT IS INTENDED THAT SUCH REFERENCES SHALL APPLY TO AS MANY SUCH DEVICES, ITEMS OR PARTS AS ARE REQUIRED TO PROPERLY COMPLETE THE WORK.EACH SECTION OF THE SPECIFICATIONS IS GOVERNED BY APPLICABLE REQUIREMENTS OF THE CONTRACT DOCUMENTS AS IF HEREIN WRITTEN. THE CONTRACTOR SHALL LAYOUT HIS OWN WORK AND SHALL PROVIDE ALL DIMENSIONS REQUIRED FOR OTHER TRADES (PLUMBING, ELECTRICAL, ETC.) THE CONTRACTOR SHALL COORDINATE WITH OWNER'S VENDORS, CONTRACTORS AND STAFF FOR SCHEDULING, ACCESS, AND/OR REMOVAL AND INSTALLATION OF ALL ASSOCIATIVE EQUIPMENT, FURNISHINGS AND APPLIANCES WITHIN THE WORK AREA. MECHANICAL, PLUMBING AND ELECTRICAL WORK SHALL BE PERFORMED BY PERSONS LICENSED IN THEIR TRADES. THE CONTRACTOR MUST SUBMIT TO THE OWNER FOR APPROVAL A BARRICADE PLAN BASED ON THE FENCING SHOWN ON THE CIVIL DRAWINGS, SHOWING SAFE INGRESS AND EGRESS FOR GUESTS DURING THE CONSTRUCTION PERIOD. SAFETY OF THE JOBSITE SHALL BE THE SOLE RESPONSIBILITY OF THE CONTRACTOR. THE CONTRACTOR SHALL PERFORM ALL CUTTING, PATCHING AND REPAIRING AS REQUIRED TO PROVIDE WORK INDICATED ON THE DRAWINGS AND ALL OTHER WORK THAT MAY BE REQUIRED TO COMPLETE THE JOB. REFER TO STRUCTURAL, MECHANICAL, PLUMBING, FIRE SAFETY AND ELECTRICAL DRAWINGS AND SPECIFICATIONS. FOR ADDITIONAL GENERAL NOTES, ABBREVIATIONS AND SYMBOLS LEGENDS, ALL NOTES ARE TO BE REVIEWED AND APPLIED TO RELATED BUILDING COMPONENTS. NOTES APPEAR ON VARIOUS SHEETS FOR DIFFERENT SYSTEMS AND MATERIALS. SHEETS ARE TO BE REVIEWED AND NOTES ON ANY ONE DRAWING ARE TO BE APPLIED TO RELATED SYSTEMS AND MATERIALS DEPICTED ON OTHER DRAWINGS. IT IS THE INTENTION OF THE KEY NOTES LOCATED ON THE VARIOUS SHEET(S) WITHIN THIS DRAWING SET TO IDENTIFY CONSTRUCTION ELEMENTS, NOT NECESSARILY DESCRIBE ENTIRE ASSEMBLIES OR PROCESSES. THE INSTALLATION OF SAID ELEMENT SHOULD INCLUDE ALL ASSOCIATED CONSTRUCTION NECESSARY TO ACHIEVE INSTALLATION AND OPERATION (USE) OF SAID ITEM. FOR EXAMPLE, THE INSTALLATION OF CERAMIC TILE SHALL INCLUDE (BUT BE NOT LIMITED TO) THE SURFACE PREPARATION, MASTIC, GROUT, EDGE STRIPS, SEALING, CLEANING, ETC. IN ADDITION, IF THE PLUMBER INSTALLS A LAVATORY, IT MEANS HE/SHE SHALL PREPARE SURFACE(S), SET LAVATORY, SEAL AROUND BOWL, PROVIDE FAUCET, CONNECT TO PLUMBING AS NECESSARY TO ACHIEVE AN AESTHETICALLY PLEASING, ACCESSIBLE (WHERE INDICATED), OPERATIONAL LAVATORY UPON COMPLETION OF THE PROJECT. ALL ELEVATIONS ARE BASED ON 0.00' REFERENCING A GRADE LEVEL OF 0.00' EXCEPT FOR ELEVATIONS THAT REFERENCE A.F.F (ABOVE FINISHED FLOOR) OR OTHER SPECIFIC INDICATOR. DIMENSIONS SHOWN ARE FOR REFERENCE AND ARE TO COMMUNICATE CRITICAL AREAS FOR DESIGN INTENT. FINAL DRAWINGS MAY VARY BASED ON CONSTRUCTION PRACTICES, LOCAL CODE REQUIREMENTS OR SPECIFIC SITE REQUIREMENTS. REFERENCE DIMENSION (RD) THESE DIMENSIONS ARE PROVIDED FOR GENERAL REFERENCE ONLY. ACTUAL DIMENSION MAY VARY BASED ON CONSTRUCTION METHOD. ROOM SIZES AND AREAS NOTE: ALL SIZES SPECIFIED IN THIS SECTION ARE THE MINIMUM SIZE FOR THAT ROOM TYPE ON THIS PROJECT, SOME ROOMS OF THE TYPE MAY BE LARGER. ACCESSIBLE ROOM MATRICIES KING ONE-BEDROOM SUITE - ACCESSIBLE / ENLARGED 26'-6" x 27'-6" 716 SF KING ONE-BEDROOM SUITE 24'-11" x 25'-1" 619 SF DOUBLE QUEEN STUDIO SUITE - ACCESSIBLE /...18'-8" x 30'-6" 562 SF DOUBLE QUEEN STUDIO SUITE 18'-5" x 29'-6" 537 SF KING STUDIO SUITE - ACCESSIBLE / ENLARGED 18'-8" x 26'-5" 483 SF KING STUDIO SUITE 18'-5" x 23'-2" 420 SF EFFICIENCY SUITE - ACCESSIBLE / ENLARGED 14'-9" x 27'-6" 400 SF EFFICIENCY SUITE 14'-3" x 25'-2" 353 SF ROOM TYPE MINIMUM ROOMDIMENSIONS MINIMUMAREA TOTAL 7 7 KING ONE-BEDROOM SUITE - BATHTUB & BALCONY 1 301 DOUBLE QUEEN STUDIO SUITE - BATHTUB 1 513 EFFICIENCY SUITE - BATHTUB 1 503 KING STUDIO SUITE - BATHTUB 5 2 138, 238 EFFICIENCY SUITE - ROLL-IN SHOWER 1 403 KING STUDIO SUITE - ROLL-IN SHOWER 2 1 338 ROOM TYPE REQUIREDCOUNT PROVIDEDCOUNT ROOMNUMBERS MOBILITY ACCESSIBLE ROOMS TOTAL 12 12 KING ONE-BEDROOM SUITE 1 202 DOUBLE QUEEN STUDIO SUITE - BATHTUB 1 322 DOUBLE QUEEN STUDIO SUITE - BALCONY 1 435 EFFICIENCY SUITE - ENLARGED 1 303 EFFICIENCY SUITE 3 133, 428, 508 KING STUDIO SUITE - BALCONY 2 325, 519 KING STUDIO SUITE 11 2 404, 530 KING STUDIO SUITE - MOBILITY ACCESSIBLE (BATHTUB) 1 1 238 ROOM TYPE REQUIREDCOUNT PROVIDEDCOUNT ROOMNUMBERS COMMUNICATION FEATURE ROOMS BACK OF HOUSE ACCESSIBLE EMPLOYEE RESTROOM (GROUND FLOOR)1 50 SF 50 SF ATTIC ACCESS (5TH FLOOR)1 67 SF 67 SF BOH DRYERS (GROUND FLOOR)1 84 SF 84 SF BOH LAUNDRY (GROUND FLOOR)1 750 SF 750 SF DAC CLOSET (TYPICAL FLOOR)4 6 SF 26 SF ELECTRICAL CLOSET (TYPICAL FLOOR)5 10 SF 49 SF ELECTRICAL MAIN ROOM (GROUND FLOOR)1 548 SF 548 SF ELECTRICAL ROOM (GROUND FLOOR)1 135 SF 135 SF EMPLOYEE RESTROOM (GROUND FLOOR)1 30 SF 30 SF EMPLOYEE ROOM (GROUND FLOOR)1 432 SF 432 SF ENGINEERING OFFICE AND STORAGE (2ND FLOOR)1 255 SF 255 SF FOOD PREP (GROUND FLOOR)1 594 SF 594 SF GENERAL MANAGER'S OFFICE (GROUND FLOOR)1 95 SF 95 SF HOUSEKEEPING OFFICE (GROUND FLOOR)1 56 SF 56 SF ICE/WATER (GROUND FLOOR)1 17 SF 17 SF IDF CLOSET (TYPICAL FLOOR)4 5 SF 19 SF LAUNDRY LOUNGE (GROUND FLOOR)1 257 SF 257 SF LINEN CHUTE (TYPICAL FLOOR)1 13 SF 13 SF LINEN DISCHARGE AND SORTING ROOM (GROUND FLOOR) 1 131 SF 131 SF LINEN STORAGE (GROUND FLOOR)1 85 SF 85 SF LINENS & HOUSEKEEPING (TYPICAL FLOOR)4 497 SF 1,989 SF MEETING STORAGE (GROUND FLOOR)1 81 SF 81 SF OPEN OFFICE (GROUND FLOOR)1 233 SF 233 SF OWNER'S OFFICE (GROUND FLOOR)1 104 SF 104 SF PANELS (TYPICAL FLOOR)4 37 SF 148 SF PBX/MDF ROOM (GROUND FLOOR)1 98 SF 98 SF POOL MECHANICAL ROOM (GROUND FLOOR)1 204 SF 204 SF SALES OFFICE (GROUND FLOOR)1 106 SF 106 SF WATER HEATER & FIRE ROOM (GROUND FLOOR)1 361 SF 361 SF 45 7,018 SF GUEST SUITE BALCONIES/LANAI BALCONY (TYPICAL FLOOR)32 VARIES 1,841 SF LANAI (GROUND FLOOR)2 54 SF 109 SF 34 1,950 SF GUEST SUITES DOUBLE QUEEN SUITE 22 VARIES 11,862 SF DOUBLE QUEEN SUITE - ENLARGED 3 568 SF 1,705 SF DOUBLE QUEEN SUITE - MOBILITY ACCESSIBLE - BATHTUB 1 565 SF 565 SF EFFICIENCY SUITE 39 VARIES 13,821 SF EFFICIENCY SUITE - ENLARGED 2 402 SF 804 SF EFFICIENCY SUITE - MOBILITY ACCESSIBLE - BATHTUB 1 399 SF 399 SF EFFICIENCY SUITE - MOBILITY ACCESSIBLE - ROLL-IN SHOWER 1 399 SF 399 SF KING 1-BEDROOM SUITE 4 619 SF 2,476 SF KING 1-BEDROOM SUITE - MOBILITY ACCESSIBLE - BATHTUB 1 712 SF 712 SF KING 1-BEDROOM SUITE- ENLARGED 3 716 SF 2,149 SF KING STUDIO SUITE 50 VARIES 21,045 SF KING STUDIO SUITE - ENLARGED 2 487 SF 973 SF KING STUDIO SUITE - MOBILITY ACCESSIBLE - BATHTUB 2 483 SF 967 SF KING STUDIO SUITE - MOBILITY ACCESSIBLE - ROLL-IN SHOWER 1 483 SF 483 SF 132 58,360 SF PUBLIC CONNECTING CORRIDOR (TYPICAL FLOOR)4 98 SF 393 SF ELEVATOR 1 1 68 SF 68 SF ELEVATOR 2 1 64 SF 64 SF ELEVATOR LOBBY (GROUND FLOOR)1 176 SF 176 SF ELEVATOR LOBBY (TYPICAL FLOOR)4 157 SF 626 SF FITNESS (GROUND FLOOR)1 801 SF 801 SF GUEST CORRIDOR (GROUND FLOOR)1 428 SF 428 SF GUEST CORRIDOR (TYPICAL FLOOR)4 1,746 SF 6,984 SF GUEST STORAGE (GROUND FLOOR)1 176 SF 176 SF LOBBY (GROUND FLOOR)1 2,670 SF 2,670 SF MEETING ROOM (GROUND FLOOR)1 406 SF 406 SF MEN'S RESTROOM (GROUND FLOOR)1 171 SF 171 SF POOL & SPLASH PAD (GROUND FLOOR)1 2,152 SF 2,152 SF POOL RESTROOM (GROUND FLOOR)1 80 SF 80 SF PUBLIC CORRIDOR- EAST (GROUND FLOOR)1 162 SF 162 SF PUBLIC CORRIDOR- WEST (GROUND FLOOR)1 711 SF 711 SF STAIR 1 5 VARIES 961 SF STAIR 2 5 VARIES 1,064 SF VESTIBULE- EAST (GROUND FLOOR)1 28 SF 28 SF VESTIBULE- LOBBY (GROUND FLOOR)1 150 SF 150 SF VESTIBULE- WEST (GROUND FLOOR)1 43 SF 43 SF WOMEN'S RESTROOM (GROUND FLOOR)1 172 SF 172 SF 39 18,488 SF SITE COURTYARD 1 3,701 SF 3,701 SF COURTYARD STORAGE CLOSET 1 46 SF 46 SF OPEN TRASH ENCLOSURE 1 385 SF 385 SF OUTDOOR KITCHEN 1 462 SF 462 SF OUTDOOR STORAGE 1 263 SF 263 SF PET RELIEF AREA 1 2,116 SF 2,116 SF PORTE-COCHERE 1 1,722 SF 1,722 SF 7 8,694 SF NOTE: ALL INTERIOR AREAS ARE CALCULATED TO FACE OF INTERIOR FINISH THESE PLANS HAVE BEEN DESIGNED IN COMPLIANCE WITH THE 2010 ADA STANDARDS AND ICC 117.1 ACCESSIBILITY REQUIREMENTS FOR ACCESSIBLE DESIGN. THE TERM "ACCESSIBLE" AND ABBREVIATIONS "ADA" OR "ADAAG" WILL BE USED THROUGHOUT THESE PLANS TO REFER TO THE 2010 ADA STANDARDS FOR ACCESSIBLE DESIGN WHICH ARE MANDATED FOR PLACES OF PUBLIC ACCOMMODATION BY TITLE III REGULATIONS OF THE ADA AT 28 CFR PART 36, SUBPART D; AND MUST FOLLOW THE 2004 ADAAG AT 36 CFT PART 1191, APPENDICES B AND D; AND ICC 117.1 ACCESSIBILITY REQUIREMENTS. THE ARCHITECT OF RECORD CERTIFIES THAT THE CONSTRUCTION DOCUMENTS MEET OR EXCEED THE ADA AND ANY STATE OR LOCAL ACCESSIBILITY CODES THAT ARE MORE STRINGENT. THE CONTRACTOR IS RESPONSIBLE FOR ABIDING BY ALL ACCESSIBILITY REQUIREMENTS ENUMERATED IN THESE DOCUMENTS OR PROVIDED BY THE ARCHITECT DURING CONSTRUCTION. THE OWNER MUST ALSO ENSURE THAT THE FACILITY IS CONSTRUCTED AND MAINTAINED IN COMPLIANCE WITH THE ADA STANDARDS. THESE PLANS IDENTIFY ACCESSIBLE MINIMUM, MAXIMUM AND DIMENSIONAL RANGES. ADDITIONAL INFORMATION REGARDING THE ADA REQUIREMENTS IS PROVIDED IN THE HILTON ACCESSIBILITY DESIGN GUIDE (HADG) AND THE 2010 AMERICANS WITH DISABILITIES ACT ACCESSIBLITY GUIDELINES. REFERENCES TO THE DIFFERENT CHAPTERS OF THE HADG OR ADAAG ARE INCLUDED WHERE APPROPRIATE. 29. 30. 31. 32. 33. 34. 35. 36. 37. 38. 39. 40. RESTORE TO THEIR ORIGINAL CONDITION ALL ELEMENTS/ITEMS DAMAGED AS A RESULT OF THE CONSTRUCTION. INCLUDING BUT NOT LIMITED TO: PAVEMENT, EMBANKMENTS, CURBS, SIGNS, LANDSCAPING, STRUCTURES, UTILITIES, WALL FENCES, WALLS, DOORS, GLAZING, TRIMS, FINISHES, ETC, WHETHER IN THE AREA OF WORK OR ELSEWHERE ON THE PREMISES, UNLESS OTHERWISE NOTED. THE COST OF RESTORING DAMAGED IMPROVEMENTS SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. THE CONTRACTOR IS TO BE RESPONSIBLE FOR JOB CLEANLINESS. THE OWNER'S FACILITIES SHALL NOT BE USED FOR CONSTRUCTION TRASH/DEBRIS DISPOSAL. EXAMINE ALL SUBSTRATES TO DETERMINE THAT THEY ARE SOUND, CLEAN AND READY TO RECEIVE FINISHES OR MILLWORK/CASEWORK PRIOR TO INSTALLATION. START OF INSTALLATION OF SAID ITEMS SHALL IMPLY ACCEPTANCE OF THE SUBSTRATE AND SHALL NOT BE GROUNDS FOR CLAIMS AGAINST IMPROPER PERFORMANCE OF INSTALLED MATERIAL. NO CHANGE ORDER WILL BE ISSUED TO RECTIFY UNSATISFACTORY SUBSTRATES ONCE WORK HAS COMMENCED. ADVISE ARCHITECT OF ANY EXISTING CONDITIONS NOT LEVEL, SMOOTH, AND PLUMB, WITHIN INDUSTRY STANDARDS, PRIOR TO START OF ANY CONSTRUCTION. CONSTRUCTION SHALL BE DONE IN CONFORMANCE WITH THE REQUIREMENTS OF THE 2010 STANDARDS FOR ACCESSIBLE DESIGN ADMINISTERED BY THE DEPARTMENT OF JUSTICE AS PART OF THE ADA. CONSTRUCTION TOLERANCES DO NOT APPLY. IDENTIFICATION MARKS SHALL BE APPLIED TO ALL INSULATION MATERIALS AND INSULATION INSTALLED SUCH THAT THE MARK IS READILY OBSERVABLE DURING INSPECTION. WHERE TWO OR MORE LAYERS OF RIGID INSULATION OR GYPSUM WALL BOARD WILL BE USED, ENSURE THAT EDGE JOINTS BETWEEN LAYERS ARE STAGGERED. PROVIDE WALL BOARD TRIM AT ALL EXPOSED EDGES AND CORNERS OF GYPSUM WALLBOARD CONSTRUCTION. J-BEAD OR OTHER NON-DRYWALL COMPOUND TRIM PIECES PROHIBITED (U.N.O.) CONTRACTOR SHALT ENSURE THAT ANY AND ALL BACK BOXES LOCATED BETWEEN LIVING OR BEDROOMS ARE NOT LOCATED BACK TO BACK OR IN THE SAME CAVITY. STAGGER BOXES ONE STUD CAVITY EITHER SIDE OF ONE ANOTHER. COORDINATE, PROVIDE, AND INSTALL 2X TREATED WOOD WALL BLOCKING OR 25 GA METAL STRAPPING AS REQUIRED FOR THE ANCHORAGE AND SUPPORT OF ALL NEW CASEWORK, TRIM, TOILET ACCESSORIES, DOOR HARDWARE ACCESSORIES, DESIGNATED ART WORK WALLS, ETC., AS APPLICABLE. ALL FLOOR AREAS THAT REQUIRE LEVELING WITH A CONCRETE TOPPING OR LEVELING COMPOUND SHALL BE INSTALLED SUCH THAT THE FLATNESS EQUALS 35/24 (ON ALL SLABS) AND THE LEVELNESS EQUALS 'SLAB ON GRADE) AND 80% OF THAT VALUE ON ELEVATED SLABS. THE CONTRACTOR IS TO PROVIDE A COMPLETE, FINISHED, AND FUNCTIONAL INSTALLATION OF ALL COMPONENTS DESCRIBED IN THESE DRAWINGS. PROJECT CLOSEOUT DOCUMENTATION IS REQUIRED INCLUDING APPLICABLE WSEC ENVELOPE COMPLIACE FORMS AND CALCULAIONS, AND FENESTRATION NFRC RATING CERTIFICATES. ACCESSIBILITY NOTES EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV Revision Schedule Number Description Date GENERAL The General Contractor shall verify all dimensions and site conditions before starting work. The Architect and Structural Engineer shall be notified of any discrepancy. Use details marked "Typical" wherever applicable. Changes, omissions or substitutions are not permitted without written approval of the Architect and Structural Engineer. Refer to specifications for further requirements. In the case of conflicts between plans and specifications, the more restrictive requirements shall apply. Any discrepancies on the Contract Documents should be brought to the attention of the Architect and Structural Engineer prior to proceeding with the work. All materials and workmanship shall conform to the 2018 edition of the International Building Code (IBC) and the 2016 edition of “Minimum Design Loads for Buildings and Other Structures” by the American Society of Civil Engineers. Use the latest edition of Referenced Standards as noted in Chapter 35 of the IBC. The Contract structural drawings represent the finished structure. The Contractor is responsible for the means, methods and sequence of construction. The design, adequacy and safety of erection bracing, shoring, temporary supports, etc., is the sole responsibility of the Contractor, and has not been considered by the Structural Engineer. The Contractor is responsible for the stability of the structure prior to the completion of all shear walls, roof and floor diaphragms and finish materials. The Contractor shall provide the necessary bracing to provide stability to the structure prior to the installation of the permanent lateral force resisting system. Observation visits to the site by the Structural Engineer shall not include inspection of temporary bracing, shoring, etc. The Contractor shall coordinate the size and locations of all openings in roofs, floors and walls. Openings shall not penetrate any structural elements such as beams, columns, walls, slabs, etc. unless noted on the drawings or approved by the Structural Engineer. DEFERRED SUBMITTALS Items designed by a Specialty Structural Engineer shall be submitted to the Architect and Structural Engineer for review and shall bear the seal and signature of an engineer registered in the state of Washington. Submittals shall include calculations, design drawings, product data and shop drawings. Design shall be based on information provided on the drawings for gravity, wind and seismic forces unless noted otherwise. The Contractor shall coordinate the seismic restraint of mechanical, plumbing and electrical equipment and the associated piping to the structure. Connections to the structure shall conform to SMACNA standards, be detailed on the contract drawings or be designed by an engineer registered in the state of Washington and submitted for Architect and Structural Engineer review prior to fabrication. SHOP DRAWINGS Shop drawings are to be checked and approved by the General Contractor prior to submitting for Architect and Structural Engineer review. General Contractor is responsible for verification and coordination of dimensions and details for each Subcontractor. Quantities and dimensions are not reviewed by the Structural Engineer and therefore must be verified by the General Contractor. No fabrication shall proceed until shop drawings have been approved. Review of the Specialty Structural Engineer’s design submittals and shop drawings is for general compliance with design criteria and compatibility with the design of the primary structure and does not relieve the Specialty Structural Engineer of responsibility for that design. DESIGN LOADS Building Risk Category -------------------------------- II Snow Loading Ground Snow Load, Pg ---------------------- 39 PSF Flat Roof Snow Load, Pf -------------------- 27 PSF Minimum Uniform Snow --------------------- 30 PSF Snow Exposure Factor, Ce ----------------- 1.0 Thermal factor, Ct ---------------------------- 1.0 Snow Load Importance Factor, Is --------- 1.0 Roof Design Load Cases: 1) Pf + Drifting/Sliding/Unbalanced 2) Minimum Uniform Snow Floor Loading Floor Live Load (Private Rooms) ---------- 40 PSF Floor Live Load (Public Rooms) ---------- 100 PSF Corridor Live Load --------------------------- 100 PSF (Serving Public Rooms) Stair Live load --------------------------------- 100 PSF (300# Concentrated Live Load) Linen Storage Live Load -------------------- 125 PSF Mechanical Room Live Load -------------- *** PSF See plans for special mechanical unit loading. Wind Loading Basic Wind Speed(3-second gust) ------- 110 MPH Wind Exposure -------------------------------- C Wind Importance Factor, IW---------------- 1.0 Enclosure Classification -------------------- Enclosed Seismic Loading - Equivalent Lateral Force Procedure Seismic Importance Factor, IE ------------- 1.0 Spectral Response Accelerations SS = 0.314 S1 = 0.112 Site Class --------------------------------------- D Seismic Design Category ------------------- C Site Coefficient Fa ---------------------------- 1.549 Site Coefficient Fv ---------------------------- 2.376 Spectral Response Coefficients ---------- SDS = 0.324 SD1 = 0.177 Basic Seismic Force-Resisting Systems: Light frame wood walls with structural wood panels Special Moment Frame Response Modification Factor, R ---------6.5 Overstrength Factor, Ω0 -------------------- 3 Deflection Amplification Factor Cd ------- 5.5 Seismic Response Coefficient, CS ------- 0.05 LRFD Solar Readiness All roof areas shall be designed for an additional dead load of 4 PSF to accommodate future photovoltaic system arrays. FOUNDATION Based on the geotechnical engineering report #221-306G by Allwest, dated January 28, 2022, design allowable soil bearing pressure = 3000 PSF. Bottom of all footings to bear on native, inorganic, undisturbed soil 1'-0" minimum below existing grade. Extend all exterior footings 2'-0" minimum below finished grade to protect against frost action. No footing shall bear higher than a 1 vertical to 1.5 horizontal slope above any excavation, existing or planned. Contractor shall provide temporary shoring to prevent movement of walls if backfill is placed before floor system is in place. Site preparation, grading, backfilling, etc. shall be as recommended by the geotechnical report. There shall be 95% compaction (ASTM D1557 Modified Proctor Density) of all backfill soil under slabs on grade. Per the geotechnical report, retaining and basement walls have been designed with the following (assumed) parameters: Equivalent Fluid Pressure: Active Condition --------------------------------------- 50 PCF At-rest/restrained Condition ------------------------ 70 PCF Passive Condition ------------------------------------- 285 PCF Soil/Concrete Friction ------------------------------------------ 0.40 CAST-IN-PLACE CONCRETE Concrete mix proportions in accordance with ACI 301 to meet or exceed the requirements as listed below: Minimum 28 Day Maximum Maximum Maximum Compressive Air Size Water/Cement Strength Entrainment Aggregate Ratio All structural conc, UNO 3000 PSI None 3/4” Footings 3000 PSI None 1-1/2" Foundation stem walls 3000 PSI 5% 3/4" Exterior C.I.P. walls 3000 PSI 5% 3/4" Topping slabs 3000 PSI None 3/8" Balcony Slab over metal deck 3500 PSI 5% 3/4” Interior slab on grade 4000 PSI None 3/4" .50(*) Polished slab on grade 4000 PSI None 1-1/2" .50 Exterior slab on grade 4500 PSI 6% 3/4" .45 Maximum Slump: Comply with typical slump ranges specified in the latest edition of ACI 211.1. Larger slumps may be allowed through the use of a super plasticizer. Construction to be in accordance with the latest edition of ACI 318, "Part 6 - Materials and Durability", "Part 8: Reinforcement", and "Part 9: Construction". Location of construction or pour joints for walls, beams, columns, and structural slabs must be approved by the Structural Engineer if different from that shown on plans. (*) Use a maximum water/cement ratio of 0.45 for interior slabs on grade that could be subject to freeze/thaw cycling while saturated during the construction period. CONCRETE SLABS ON GRADE The General Contractor shall control and monitor construction procedures and conditions as required to provide a high quality finished slab with minimal cracks, curling, and surface defects. Procedures and conditions under the control of the General Contractor include, but are not limited to: provisions for ambient weather conditions, curing methods selected, rate of placement, joint arrangement and installation, temperature control, subgrade preparation, and reinforcing placement (where indicated). Placement on Vapor Barrier: Slabs poured directly on vapor barrier are intended to facilitate vapor- emission rates frequently required for floor covering installation. Concrete cure time may be longer than for slabs not in direct contact with vapor barrier; General Contractor to coordinate curing and floor covering installation requirements as required. Slab Finishes: Concrete slabs on grade shall be provided with finish techniques in accordance with the floor classification table of ACI 302.1R. Intended use for interior slabs shall be categorized as either Class 2, Class 4, or Class 5, unless noted otherwise. Slab Joints: Except where specifically indicated, joint spacing and arrangement is to be determined by the General Contractor as part of slab installation procedure. A proposed joint layout plan shall be submitted for architect and engineer approval prior to slab pour. In general, apply the following parameters: Maximum joint spacing, subject to factors above: Typical, UNO: 36 times slab thickness Exposed & Polished slabs: 24 times slab thickness Maximum aspect ratio between joints: 1.5 to 1 Avoid re-entrant corners POLISHED CONCRETE SLABS ON GRADE The General Contractor shall comply with all provisions noted above, plus additional requirements listed here. Crack control and minimization is imperative at all polished slab areas. Concrete Mix: Fly ash, water vapor reducing admixtures, and air entraining admixtures are not to be included in the mix design. Fiber reinforcement shall not be provided in polished slabs. Maximum cement content shall be 517# per cubic yard (5.5 sack mix). Mix design shall provide for maximum curing shrinkage of 0.0003" per inch. Slab Joints: A proposed joint-layout plan shall be submitted for architect and engineer approval prior to slab pour. Reference the architectural drawings for preferred joint locations, and follow joint parameters noted above for standard slabs on grade. FIBER REINFORCEMENT Where fiber reinforcement is specified on the plans for concrete slabs on grade, provide synthetic macrofibers made of 100% virgin copolymer/polypropylene complying with ASTM C 1116, Type III, minimum 2" fiber length, aspect ratio of 50 to 90, at a dosage rate of 4.0 LBS/CY, unless noted otherwise. Follow manufacturer's recommendations for proper batching and mixing procedures. MASONRY Design Compressive Strength:CMU masonry f'm = 2000 PSI at 28 days. Concrete Masonry Units: ASTM C90-14, medium weight(115 pcf), running bond. Minimum compressive strength = 2000 PSI. Mortar: ASTM C270, Type S, with a minimum compressive strength of 1800 PSI at 28 days. Grout: ASTM C476 with a minimum compressive strength of 2000 PSI at 28 days with a maximum aggregate size of 3/8”. Fill all cells containing reinforcing with grout in lifts not exceeding 5'-4" in height. Stop each grout lift 1 ½” below the top course in the lift except at the top of the wall. Fill other cells with grout as indicated on drawings. Unless noted otherwise, lap all bar splices 48 diameters minimum. All reinforcement shall be in place prior to grouting with vertical bars held at top, bottom and 192 diameters maximum on center. Contractor shall provide temporary bracing for masonry walls, as required, until connections to floor and/or roof diaphragms are completed. REINFORCING STEEL Welded Wire Fabric: ASTM A1064, Fy = 65 KSI supplied in flat sheets and lapped a minimum of 12” on all sides. Deformed Bars: ASTM A615, Grade 60. Weldable Deformed Bars: ASTM A706, Grade 60 for #4 and larger. Securely tie in place with double annealed 16 gauge iron wire or approved clips. Provide chairs, bolsters, etc. to place reinforcement in the proper positions as indicated on the drawings. Unless otherwise noted on these drawings, provide clear embedment at reinforcing bars as follows: Concrete cast against soil = 3". Formed concrete against soil = 2". Walls, columns and beams exposed to weather = 2". Walls, columns and beams not exposed to weather = 1 1/2". Slab on grade = 2". Detailing of concrete reinforcement bars and accessories shall conform to the recommendations of ACI 315 “Details and Detailing of Concrete Reinforcement” and ACI SP-66 “Detailing Manual”. Placing of reinforcement shall conform to ACI 315R “Manual of Engineering and Placing Drawings for Reinforced Concrete Structures” and CRSI “Manual of Standard Practice”. Reinforcement bars shall not be tack welded, heated, or cut unless specifically detailed on the drawings or as approved by the Structural Engineer. The welding of reinforcing steel, metal inserts and connections in reinforced concrete shall conform to AWS D1.4 “Structural Welding Code – Reinforcing Steel” by AWS/WABO certified welders using E9018 or approved electrodes. Submit mill test report of material properties to determine carbon equivalent and minimum preheat temperatures. ASTM A706 reinforcement may be substituted for A615 reinforcement. Submit shop drawings of reinforcing steel for review by the Structural Engineer prior to fabrication. All wall reinforcement shop drawings shall be shown in elevation. STRUCTURAL AND MISCELLANEOUS STEEL C & L Shapes, plates and bars: ASTM A36, Fy = 36 KSI HP Shapes: ASTM A572, Fy = 50 KSI Wide Flange & WT Shapes: ASTM A992, Fy = 50 KSI Pipe: ASTM A53, Grade B, Type E or S, Fy = 35 KSI minimum. Square & Rectangular HSS: ASTM A500, Grade C, Fy = 50 KSI Round HSS: ASTM A500, Grade C, Fy = 50 KSI Bolts: ASTM A307 machine bolts (MB). High Strength Bolts: ASTM A325 high strength bolts (HSB),Type 1 with ASTM F436 hardened steel washers and ASTM A563 heavy hex nuts. High strength bolts shall be installed to a "snug tight" condition where all plies of the joint are in firm contact for typical beam end connections, column cap plate connections, etc. unless noted otherwise. Where noted as “slip-critical” (SC), high strength bolts shall be installed with load indicator devices (ASTM F959 load indicator washers or ASTM F1852 snap-off heads). Provide a Class A faying surface on connected elements. Anchor Rods(AR):Headed or threaded rod with heavy hex nut, ASTM F1554, Fy = 36 KSI with A563C (A563DH for galvanized) heavy hex nuts and F436-1 washers. (F1554 is also available in 55 KSI and 105 KSI) Anchor Bolts(AB):Headed A307, Grade A or hooked ASTM A36. Threaded rod:ASTM A36, Fy = 36 KSI. Headed anchor stud (HAS): ASTM A108 Type A, Fy = 49 KSI for general use and Type B, Fy = 51 KSI for composite steel-concrete construction. Headed anchor studs shall be end welded per manufacturer's recommendations. Deformed bar anchors (DBA): ASTM A1064, Fy = 70 KSI, end welded per manufacturer's recommendations. Threaded Anchor Stud (TAS): ASTM A108, Fy = 49 KSI, end welded per manufacturer's recommendations. Welding electrodes or wires: AWS A5.1 or A5.5, E70XX; AWS A5.18, E70S-X; AWS A5.20, E7XT-X. Non-shrink Grout: "Masterflow 928" as manufactured by BASF Building Systems or approved equal with a minimum compressive strength of 5000 PSI. Erection and fabrication in accordance with AISC 360 “Specification for Structural Steel Buildings”, AISC 341 “Seismic Provisions for Structural Steel Buildings”, and AISC 303 “Code of Standard Practice for Steel Buildings and Bridges”. Welding shall conform to AWS D1.1 "Standard Welding Code - Steel". All welding shall be performed by AWS/WABO Certified Welders whose certification meets "AWS Standards" in an approved fabricator shop or where Special Inspection is provided. All columns and beams to be from unspliced lengths unless noted otherwise on the drawings. All members to have "Standard" size holes unless noted as short-slotted (SSL) or long-slotted (LSL). Enlargement of holes by burning is not permitted. Submit shop drawings showing sizes, dimensions and required connection details for review by the Architect and Structural Engineer prior to fabrication. STEEL DECK Provide steel deck of depth and gage indicated on the structural drawings in conformance with ASTM A653 or A1063, Grade 50 Structural Quality with G60 zinc coating (G90 at exterior balconies). Conform with ASTM A653 SS, Grade 80 for shallow and deep Vercor form deck. Individual sheet length shall be continuous for 3 or more spans. Provide flashing and closures at all locations as required for the deck to receive concrete. All deck welding shall be in accordance with AWS D1.3 “Structural Welding Code – Sheet Steel”. No hangers for piping, ductwork, etc. shall be directly attached to steel roof deck. Submit shop drawings showing layout for review by the Architect and Structural Engineer. LIGHTGAGE STRUCTURAL STEEL STUDS AND JOISTS Studs and track, 18(43 mils) & 20(33 mils) gage bridging, and accessories:Fy = 33 KSI conforming to ASTM A653 SS (Galvanized). Studs and track, 14(68 mils) & 16(54 mils) gage: Fy = 50 KSI conforming to ASTM A653 SS Class 1 or 3 (Galvanized). Unpunched joists, 18 gage(43 mils): Fy = 33 KSI conforming to ASTM A653 SS (Galvanized). Unpunched joists, 12(97 mils), 14(68 mils), and 16(54 mils) gage: Fy = 50 KSI conforming to ASTM A653 SS Class 1 or 3. All structural properties computed in accordance with latest edition of AISI S100 "North American Specification for the Design of Cold Formed Steel Structural Members". Designations on the drawings are Steel Stud Manufacturer's Association. Approved equivalent products may be permitted upon written approval of the Architect and Structural Engineer. Install members in accordance with industry standards. Unless otherwise noted on these drawings, stud wall track to be of the same material and gage as studs. Provide horizontal bridging at 5'-0" o.c. maximum at non-bearing walls and 3'-4" o.c. maximum at bearing walls. Bearing walls to be erected with stud ends seated against track web top and bottom with a maximum of 1/16” clearance. Submit shop drawings showing stud and joist layout, dimensions, sizes, bridging and required connection details for review by the Architect and Structural Engineer. All welding to be performed by AWS/WABO Certified Welders in accordance with AWS D1.3 “Structural Welding Code – Sheet Steel”. WOOD Sawn Lumber:Douglas Fir-Larch S-Dry 19% MC, WWPA 2017 Western Lumber grading rules furnished to the following minimum standards: Studs 2x4 Standard or better 2x6 #2 or better Joist & Rafters 2x, 3x, 4x widths 6" to 14" deep #2 or better Top & Sill Plates 2x width #2 or Construction Grade Beams & Stringers 6x widths & larger #1 or better Posts and Timbers 6x widths & larger #1 or better T&G Decking 2x, 3x, 4x widths Selected Grade Treated Framing 2x, 3x, 4x widths Hem-Fir #2 or better FRT Studs/Plates/hdrs 2x, 3x, 4x widths All wood bearing on concrete or masonry, if less than 4'-0" above grade, shall be preservative treated. Structural members shall not be cut for pipes, ducts, etc., unless specifically noted or detailed. Glued-Laminated Timbers: All members shall conform to the latest edition of AITC 117 "Design Standard Specifications for Structural Glued-Laminated Timber of Softwood Species". Simple-span beams: Stress Class 24F-1.8E Combination Symbol 24F-V4 Continuous beams: Stress Class 24F-1.8E Combination Symbol 24F-V8 Cantilever beams: Stress Class 24F-1.8E Combination Symbol 24F-V8 Compression members: Combination Symbol 2 Tension members: Combination Symbol 3 Camber all simple-span beams to a radius of 5000 feet, unless noted otherwise on the plans. Shop Drawings of glu-laminated members shall be submitted for review by the Structural Engineer prior to fabrication. Roof Sheathing: 5/8” (19/32” minimum) APA rated sheathing, Exposure 1, PRP-108, ESR-2586, Span Rating 40/20. Provide tongue & groove edges, ply clips, or blocking at all panel edges where roof slopes are less than 2:12, or spacing of support framing exceeds 32” oc, or where noted on the drawings. Lay sheathing with face grain perpendicular to supports continuous over 2 or more spans with end joints staggered. Allow 1/8" spacing at panel ends and edges. Attach to framing with 8d @ 6” oc at panel edges and 12” oc at intermediate supports unless noted otherwise. Floor Sheathing: 3/4” (23/32” minimum) APA rated sheathing, Exposure 1, PRP-108, ESR-2586, Span Rating 48/24, with tongue & groove edges. Lay sheathing with face grain perpendicular to supports continuous over 2 or more spans with end joints staggered. Allow 1/8" spacing at panel ends and edges. Sheathing shall be field-glued to support framing using adhesives meeting APA Specification AFG-01 applied per manufacturer's recommendations. Tongue and groove edges shall also be field-glued. Attach to framing with 8d @ 6” oc at panel edges and 12” oc at intermediate supports unless noted otherwise. Wall Sheathing: 1/2” (15/32” minimum) APA rated sheathing, Exposure 1, PRP-108, ESR-2586, Span Rating of 24/0. Provide solid blocking at all panel edges. Lay sheathing with face grain perpendicular to supports continuous over 2 or more spans. Allow 1/8" spacing at panel ends and edges. Attach to framing with 8d @ 6” oc at panel edges and 12” oc at intermediate supports unless noted otherwise. Framing anchors and connectors: "Simpson" or approved equal as indicated on drawings. Install per manufacturer's recommendations. Bolt heads and nuts in contact with wood shall have washers. For nailing not shown on drawings, use IBC Fastening Schedule, Table 2304.10.1. Nails shall not be overdriven. Preservative-Treated Wood:LSB Staff: See Office Design Std D-08 All preservative-treated wood (PT) and fire-treated wood (FT) shall be treated in compliance with the American Wood Protection Association (AWPA) standard U1-09. The AWPA Use Category System (UCS) shall be used to determine an appropriate AWPA-approved preservative system and retention level for specific commodities and end-uses. Unless otherwise specified, species and retention levels used in the preservative system shall be compliant with those listed in Section 6 of AWPA-U1-09. Treatments CCA-C, ACQ-A, and ACQ-B are prohibited. All framing hardware, connectors, etc. in contact with treated wood shall be galvanized per ASTM A653 or stainless steel. All framing hardware fasteners into treated wood shall be galvanized per ASTM A153 or stainless steel. METAL PLATE CONNECTED WOOD TRUSSES Maximum truss spacing: 24" o.c. Truss loading unless noted otherwise on drawings: Top chord live load = See "DESIGN LOADS" Top chord dead load = 8 PSF + Solar Readiness Bottom chord live load = 10 PSF (Not capable of storage) Bottom chord dead load = 8 PSF Design trusses for wind uplift for components and cladding per ASCE 7-10, Section 30.4 (enclosed). Verify weight and locations of all mechanical equipment to be supported by trusses prior to fabrication. Camber trusses for dead load deflection. Live load deflection should not exceed L/360. Trusses to be fabricated by a certified member of the Structural Building Components Association (SBCA) meeting the requirements of an “Approved Fabricator” per IBC 1704.2.5.1 or where “Special Inspection” at the fabrication site is provided. Design and fabrication to conform to the Truss Plate Institute Standard ANSI/TPI 1-2007. Connector plates shall be ICC approved. Connector plates shall be sized for 150% (175% for scissor trusses) of member forces with a minimum size of 3"x5". Truss designs and shop drawings shall be stamped by a professional engineer registered in the State of Washington. Shop drawings shall include, for each type of truss, dimensions and configurations, nominal lumber size and grade, specifications for connector plates used, size and location of each connector at each joint and amount of camber if required. Shop drawings shall include erection plans showing truss spacing, truss mark numbers (corresponding to the design calculations), concentrated loads, and permanent bracing/bridging as required by the truss design. Erection bracing shall comply with Truss Plate Institute “Building Component Safety Information, BCSI 2006: Guide to Good Practice for Handling, Installing, Restraining & Bracing of Metal Connected Wood Trusses". Design calculations and shop drawings shall be submitted for review by the Architect and Structural Engineer prior to fabrication. PROPRIETARY WOOD PRODUCTS Floor Dead Load = 25 PSF Floor Live Load = See "DESIGN LOADS" TimberStrand LSL 1.55E Fb = 2325 PSI by TrusJoist Weyerhauser TimberStrand 1 ¼” Rimboard 1.3E Fb = 1700 PSI by TrusJoist Weyerhauser Microlam LVL 2.0E Fb = 2600 PSI by TrusJoist Weyerhauser Parallam PSL 2.0E Fb = 2900 PSI by TrusJoist Weyerhauser Redlam LVL 2.0E Fb = 2900 PSI by RedBuilt Premanufactured wood I-joists, beams, and trusses to have ICC acceptance, and be of the same depths and spacing as noted on the framing plans. Member designations shown on the drawings correspond to TrusJoist Weyerhauser or RedBuilt products; products from other manufacturers may be substituted if they have equivalent load carrying capacities and meet the depth, spacing and fire resistance requirements shown on the drawings. Product substitution shall be approved by the Structural Engineer prior to bid date. Install the product per manufacturer's recommendations. Submit shop drawings of layout and required connection details for review by the Architect and Structural Engineer prior to fabrication. POST-INSTALLED ANCHORS All post-installed anchors shall have current ICC ESR Reports indicating code-approved installation requirements. Contractor shall comply with all requirements of the ESR report. Substitution of post- installed anchors for anchor bolts, anchor rods, or rebar dowels is not allowed without written approval of the Structural Engineer. Special Inspection is required for all post-installed anchors. Special Inspection for Contractor-requested substitutions (if approved) shall be provided at no additional cost to the Owner. Adhesive Anchors (AA) in Concrete: ASTM A307, Grade C threaded rod with Simpson SET-3G adhesive or Hilti “HAS-E” threaded rod or Grade C threaded rod with HIT-HY 200 adhesive or approved equal. Concrete to have aged a minimum of 21 days prior to installation. Adhesive Dowels (AD) in Concrete: ASTM A615 deformed bar with Simpson SET-3G adhesive or Hilti HIT-HY-200 adhesive or approved equal. Concrete to have aged a minimum of 21 days prior to installation. Powder Actuated Fasteners(PAF)into Steel: Hilti X-U 15(.145” dia) fasteners into steel of a minimum 3/16” thickness. QUALITY ASSURANCE and SPECIAL INSPECTIONS A qualified special inspector(s) shall be engaged by the Owner or Owner’s representative to conduct continuous and periodic inspections as tabulated on sheet S003. Construction activity shall be coordinated with required inspections and testing requirements by the Contractor. Construction deficiencies identified by the special inspection process shall be remedied by the Contractor at no cost to the Owner. 737 BISHOP STREET, SUITE 1860 HONOLULU, HI 96813 808-352-5299 OWNER: 523 EAST THIRD AVENUE SPOKANE, WA 99202 P 509.323.9292 F 509.747.7115 HOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 99216GENERAL STRUCTURAL NOTES S001 FSC PROJECT NO. 21012 PERMIT SET 5/31/2024 GL8 Mirabeau Point, LLC 10909 E. Pierce Lane Spokane, WA 99206 (509) 919-0901 GENERAL STRUCTURAL NOTES Revision Schedule Number Description Date J.B. T.O.W. T.O.P. T.O.B. T.O.S. T.O.C. T.O.F. T.O.M. FIN SLAB -SS- - - - - - - LEGEND CMU WALL TOP OF CONCRETE ELEVATION TOP OF FOOTING ELEVATION TOP OF SLAB ELEVATION TOP OF PARAPET ELEVATION TOP OF BEAM ELEVATION TOP OF WALL ELEVATION ELEVATION CHANGE STEPPED FOOTING BM SIZE (114'-2") (C=¼") W16x31 [10] FOOTING MARK METAL STUD WALL HOLDOWN MARK TOP OF BM ELEVATION BEAM DESIGNATION ROOF TOP MOUNTED MECH UNIT WEIGHT AS NOTED SLAB JOINT FINISH FLOOR ELEVATION SHEAR WALL MARK DETAIL MECH UNIT MOUNTED UNDER AND FROM FRAMING W/WEIGHT SECTION NUMBER SHEET NUMBER ELEVATION ELEVATION LETTER DETAIL NUMBER SHEET NUMBER SHEET NUMBER BUILDING SECTION WOOD STUD WALL CAMBER SHEAR STUDS, SEE TYPICAL DETAILS REVISION MARK CONTROL JOINT JOIST BEARING ELEVATION F3 1 1 C JS J2558.56' 800# 800# CONTINUOUS FOOTING MARKCF3 TOP OF MASONRY ELEVATION FINISHED SLAB ELEVATION MATCHLINE THICKENED SLAB FOOTING MARKTS3 STEM WALL MARKSW8 1. THE CONTINUOUS ROD TIEDOWN SYSTEM FOR THIS PROJECT SHALL BE THE SIMPSON STRONG-TIE STRONG-ROD ANCHOR TIEDOWN SYSTEM (ATS) FOR SHEARWALL OVERTURNING RESTRAINT. 2. SIMPSON STRONG-TIE SHALL PROVIDE THE ATS TO MEET THE DESIGN FORCES, TOTAL VERTICAL DISPLACEMENT LIMIT, AND SHRINKAGE REQUIREMENTS AS SET FORTH IN THE STRUCTURAL DRAWINGS. ATS CALCULATIONS AND INSTALLATION DETAILS SHALL BE PROVIDED TO THE DESIGNER OR ENGINEER OF RECORD FOR REVIEW AND APPROVAL. 3. ALLOWABLE ROD CAPACITIES SHALL BE CALCULATED PER AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC) SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS. a. AISC 360 - 16 FOR 2018 INTERNATIONAL BUILDING CODE 4. BEARING PLATE, WOOD STUD AND FASTENER CAPACITIES SHALL BE CALCULATED PER THE NATIONAL DESIGN SPECIFICATION (NDS) FOR WOOD CONSTRUCTION. a. NDS - 18 FOR 2018 INTERNATIONAL BUILDING CODE 5. SHRINKAGE COMPENSATING DEVICES SHALL BE PROVIDED AT EACH RESTRAINT LOCATION AND ACCOUNT FOR THE SHRINKAGE AMOUNT AT EACH STORY AS SET FORTH ON THE STRUCTURAL DRAWINGS. 6. THE TOTAL VERTICAL DISPLACEMENT BETWEEN RESTRAINT LOCATIONS, INCLUDING STEEL ROD ELONGATION AND SHRINKAGE COMPENSATING DEVICE DEFLECTION, SHALL BE LESS THAN 0.20 INCHES OR AS SET FORTH IN THE STRUCTURAL DRAWINGS, USING ALLOWABLE STRESS DESIGN (ASD). STEEL ROD ELONGATION SHALL BE COMPUTED AS THE PRODUCT PL/AE, WHERE P IS THE AXIAL LOAD (LB.), L IS THE INITIAL ROD LENGTH BETWEEN RESTRAINT LOCATIONS AT THE STORY UNDER CONSIDERATION (INCHES), E IS 29,000,000 (PSI) AND A IS THE NET TENSILE AREA OF THE ROD (IN.2). SHRINKAGE COMPENSATING DEVICE DEFLECTION SHALL BE AS SPECIFIED IN ICC-ES ESR-2320 INCLUDING R + A (PD/PA). 7. THE ATS SHALL BE RESTRAINED BY A BEARING PLATE AND TAKE-UP DEVICE ASSEMBLY AT EACH STORY OF THE MULTI-STORY SHEARWALLS. NOTE: SKIPPING STORIES, WHERE BEARING PLATES ARE OMITTED AT INTERMEDIATE FLOORS THAT RESULT IN MULTIPLE STORIES BEING TIED TOGETHER, IS PROHIBITED. 8. DO NOT WELD PRODUCTS UNLESS THE ATS INSTALLATION DETAILS SPECIFICALLY IDENTIFY A PRODUCT AS ACCEPTABLE FOR WELDING. SOME STEELS HAVE POOR WELDABILITY AND A TENDENCY TO CRACK WHEN WELDED. RODS, NUTS, AND COUPLER NUTS SHALL NOT BE WELDED. 9. IN THE EVENT OF A DISCREPANCY BETWEEN THE STRUCTURAL DRAWINGS AND THE ATS INSTALLATION DETAILS, THE STRUCTURAL DRAWINGS SHALL GOVERN. 10. THE STRUCTURAL DRAWINGS ARE SPECIFIC TO THE SIMPSON STRONG-TIE STRONG-ROD ANCHOR TIEDOWN SYSTEM (ATS) AND ARE NOT APPLICABLE TO OTHER MANUFACTURERS’ CONTINUOUS ROD TIEDOWN SYSTEMS. PROPOSED SUBSTITUTIONS OF OTHER MANUFACTURERS’ CONTINUOUS ROD TIEDOWN SYSTEMS SHALL BE SUBMITTED TO THE DESIGNER OR ENGINEER OF RECORD FOR REVIEW AND APPROVAL AT THE CONTRACTOR’S EXPENSE. SUBMITTAL SHALL INCLUDE EVALUATION REPORTS INDICATING COMPLIANCE WITH GOVERNING BUILDING CODES AND TEST DATA PERFORMED IN ACCORDANCE WITH ICC-ES ACCEPTANCE CRITERIA FOR SHRINKAGE COMPENSATING DEVICES (AC316). IN ADDITION, SUBMITTAL SHALL INCLUDE INSTALLATION DETAILS AND INSTRUCTIONS, CALCULATIONS IN ACCORDANCE WITH THE GOVERNING BUILDING CODES, AND CERTIFICATION BY THE MANUFACTURER OF COMPLIANCE WITH THESE ATS SPECIFICATIONS AND THE STRUCTURAL DRAWINGS. 11. ATS RUN START/TERMINATIONS SHALL BE AS SET FORTH ON THE STRUCTURAL DRAWINGS. ALTERNATE RUN START/TERMINATIONS SHALL BE SUBMITTED TO THE DESIGNER OR ENGINEER OF RECORD FOR REVIEW AND APPROVAL PRIOR TO PLACEMENT OF THE CONCRETE AND AT THE CONTRACTOR’S EXPENSE. SUBMITTAL SHALL INCLUDE CALCULATIONS IN COMPLIANCE WITH THE GOVERNING BUILDING CODE, INCLUDING CONCRETE ANCHORAGE IN ACCORDANCE WITH ACI 318 PROVISIONS FOR STRENGTH DESIGN AND CONVERSION TO ASD LOAD LEVELS. 12. THE ATS IS DESIGNED TO BE INSTALLED FLOOR BY FLOOR AS THE STRUCTURE IS BUILT. INSTALLATION IN THIS MANNER, WITH SHEARWALLS, WILL PROVIDE A LATERAL-FORCE-RESISTING SYSTEM DURING CONSTRUCTION. THE DESIGN AND EXPENSE OF ALTERNATIVE METHODS OF TEMPORARY LATERAL-FORCE-RESISTING SYSTEMS ARE THE RESPONSIBILITY OF THE CONTRACTOR. 13. A PRE-CONSTRUCTION MEETING IS RECOMMENDED WITH SIMPSON STRONG-TIE PRIOR TO PLACEMENT OF THE CONCRETE. THE PURPOSE OF THIS MEETING IS TO ASSIST IN VERIFYING QUANTITIES AND UNDERSTANDING THE INSTALLATION PROCESS. TO COORDINATE THIS MEETING, CALL SIMPSON STRONG-TIE AT (800) 999-5099. GENERAL NOTES FOR SIMPSON STRONG-TIE® STRONG-ROD ANCHOR TIEDOWN SYSTEM 737 BISHOP STREET, SUITE 1860 HONOLULU, HI 96813 808-352-5299 OWNER: 523 EAST THIRD AVENUE SPOKANE, WA 99202 P 509.323.9292 F 509.747.7115 HOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 99216ABBREVIATIONS & LEGEND S002 FSC PROJECT NO. 21012 PERMIT SET 5/31/2024 GL8 Mirabeau Point, LLC 10909 E. Pierce Lane Spokane, WA 99206 (509) 919-0901 AA ADHESIVE ANCHOR AB ANCHOR BOLT AD ADHESIVE DOWEL ADD'L ADDITIONAL AFF ABOVE FINISH FLOOR ALT ALTERNATE & AND APPROX APPROXIMATE AR ANCHOR ROD ARCH ARCHITECT ARCHL ARCHITECTURAL @ AT B.O. BOTTOM OF BOT BOTTOM BLDG BUILDING BLKG BLOCKING BM BEAM BRG BEARING BSMT BASEMENT BTWN BETWEEN C CHANNEL CB CARRIAGE BOLT CDF CONTROLLED DENSITY FILL CL OR CENTERLINE CLG CEILING C-C CENTER TO CENTER CF CUBIC FEET CIP CAST-IN-PLACE CJ CONTROL JOINT CLR CLEAR CMU CONCRETE MASONRY UNIT CNTRD CENTERED COL COLUMN CONC CONCRETE CONN CONNECTION CONSTR CONSTRUCTION CONT CONTINUOUS CONTR CONTRACTOR CTSK COUNTERSINK CTR CENTER CY CUBIC YARD DBA DEFORMED BAR ANCHOR DBL DOUBLE DEG DEGREE DIAG DIAGONAL DIA DIAMETER DIM DIMENSION DL DEAD LOAD DN DOWN DP DEEP DTL DETAIL DWG DRAWING DWL DOWEL (E) EXISTING EA EACH EB EXPANSION BOLT EF EACH FACE EJ EXPANSION JOINT ELEV ELEVATION EMBED EMBEDMENT EN EDGE NAIL ENGR ENGINEER EQ EQUAL EW EACH WAY EXP EXPANSION EXIST EXISTING EXTR EXTERIOR FD FLOOR DRAIN FDN FOUNDATION FIN FINISH FLR FLOOR FN FIELD NAIL F.O. FACE OF F.O.C. FACE OF CONCRETE FRMG FRAMING FS FAR SIDE FT FEET FTG FOOTING STRUCTURAL ABBREVIATIONS GA GAUGE GALV GALVANIZE GL GLUED LAMINATED GR GRADE GWB GYPSUM WALLBOARD H HORIZONTAL HAS HEADED ANCHOR STUD HDR HEADER HGR HANGER HORIZ HORIZONTAL HSB HIGH STRENGTH BOLT HSS HOLLOW STRUCTURAL SECTION HT HEIGHT HWH HEX WASHER HEAD I.D. INSIDE DIAMETER I.F. INSIDE FACE IN INCH(ES) INTR INTERIOR JST JOIST JT JOINT JB JOIST BEARING K KIP KSF KIPS PER SQUARE FOOT L OR ANGLE LBS POUNDS LL LIVE LOAD LLBB LONG LEGS BACK TO BACK LLH LONG LEG HORIZONTAL LLV LONG LEG VERTICAL LNTL LINTEL LONG LONGITUDINAL LSL LAMINATED STRAND LUMBER LVL LAMINATED VENEER LUMBER MAS MASONRY MAX MAXIMUM MB MACHINE BOLT MECH MECHANICAL MEZZ MEZZANINE MFR MANUFACTURER MIN MINIMUM MISC MISCELLANEOUS ML MICROLLAM M.O. MASONRY OPENING MTL METAL # OR NO. NUMBER NIC NOT IN CONTRACT NOM NOMINAL NS NEAR SIDE NTS NOT TO SCALE OC ON CENTER O.D. OUTSIDE DIAMATER O.F. OUTSIDE FACE OH OVERHEAD O-O OUT TO OUT OPNG OPENING OPP OPPOSITE PAF POWDER ACTUATED FASTENER PC PRECAST PL OR PLATE PLF POUNDS PER LINEAL FOOT PCF POUNDS PER CUBIC FOOT PLYWD PLYWOOD PLCS PLACES PSF POUNDS PER SQUARE FOOT PSI POUNDS PER SQUARE INCH PSL PARALLAM PT PRESSURE TREATED RAD RADIUS R RISER REINF REINFORCEMENT REF REFERENCE REQD REQUIRED REQMTS REQUIREMENTS REV REVISION R.O. ROUGH OPENING RM ROOM SA SCREW-IN ANCHOR SCHED SCHEDULE SF SQUARE FEET SHT SHEET SHTG SHEATHING SIM SIMILAR SPCS SPACES SPECS SPECIFICATIONS SQ SQUARE SSL SHORT SLOTTED SJ SLAB JOINT SS STAINLESS STEEL STD STANDARD STIFF STIFFENER STGRD STAGGERED STL STEEL STUC STRUCTURAL SYM SYMMETRICAL TAS THREADED ANCHOR STUD T & B TOP AND BOTTOM THK THICK THRD THREADED TN TOE NAIL T.O. TOP OF TRANS TRANSVERSE TS TUBE STEEL TYP TYPICAL UA UNDERCUT ANCHOR UNO UNLESS NOTED OTHERWISE V VERTICAL (V) VERIFY VERT VERTICAL W/ WITH W/O WITHOUT WD WOOD WF WIDE FLANGE WP WORK POINT WS WATERSTOP WT STRUCTURAL TEE SECTION WT WEIGHT WWF WELDED WIRE FABRIC x TIMES OR BY Revision Schedule Number Description Date X X X X X X X X X X X X X Inspect reinforcing steel including prestressing tendons and verify placement ACI 318 20, 25.2, 25.3, 26.6.1-26.6.3, IBC 1908.4 P Cast-in-Place anchors in concrete ACI 318 17.8.2 P Verify use of required mix designs ACI 318 19, 26.4.3 & 26.4.4 IBC 1904.1, 1904.2,1908.2,1908.3 P Sampling of fresh concrete for strength tests, slump and air content tests and to determine temperature of the concrete ACI 318 26.5 & 26.12 ASTM C172 & C31 IBC 1908.10 C Inspect concrete and shotcrete placement for proper application techniques ACI 318 26.5, 26.13.3.2(a) IBC 1908.6, 1908.7 &1908.8 C Verify maintenance of specified curing temperature and techniques ACI 318 26.5.3 -26.5.5 IBC 1908.9 P Inspect prestessed concrete for application of prestressing forces & grouting of bonded tendons ACI 318 26.10 & 26.13.3.2 C Inspect erection of precast concrete members ACI 318 26.9 & 26.13.3.3 Verification of in-situ concrete strength prior to stressing tendons in post-tensioned concrete ACI 318 26.11.2 P Verification of in-situ concrete strength prior to removal of forms and shores from elevated beams and slabs ACI 318 26.11.2 P Inspect formwork for shape, location and dimensions of the member being formed ACI 318 26.11.1.2(b)P Placement of Reinforcing steel & Concrete in Special Moment Frames ACI 318 18.2.5, 18.2.6, 26.13 C Placement of Reinforcing steel & Concrete in Special Shear Walls ACI 318 18.2.5, 18.2.6, 26.13 C Concrete Placement for composite slabs AISC 341 J9 C Stressing of Tendons in Post-tensioned concrete ACI 318 26.10.2 & 26.13.3.2 C CONCRETE System or Material Code Reference Frequency Required 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. P Verification of Weldability if other than ASTM A706 ACI 318 26.6.4, AWS D1.4 P ACI 318 26.6.4, AWS D1.4 P Inspect all other welds ACI 318 26.6.4, AWS D1.4 C Adhesive anchors installed horizontally or upwardly inclined and resisting sustained tension loads ACI 318 17.8.2.4, ICC Report C Mechanical anchors and other adhesive anchors ACI 318 17.8.2, ICC Report P a. b. c. a. b. Inspect single pass fillet welds, maximum 5/16” Welding Reinforcing Steel16. 17.Post-Installed Anchors in Hardened Concrete X X X X X SOILS AND FOUNDATION System or Material Code Reference Frequency Required 1. 2. 3. 4. 5. SPECIAL INSPECTION, TESTING AND STRUCTURAL OBSERVATION GENERAL The Owner or the Owner's agent shall employ an approved agency to perform inspections and testing during construction in accordance with IBC sections 1704, 1705 and 1707 and the Statement of Special Inspections below. These inspections are in addition to the inspections required per IBC section 110. Special Inspectors shall be qualified persons with experience in the types of construction being inspected. Special Inspectors shall provide written documentation of WABO or equivalent certification acceptable to the Agency Having Jurisdiction. Off-site work and fabrications do not require special inspection if the fabricator is registered and approved to perform such work by the Agency Having Jurisdiction. Approval is based on the fabricator's written procedures and quality control programs. CONTRACTOR RESPONSIBILITIES The Contractor shall provide reasonable access to all work requiring special inspection and notify the Inspection Company in sufficient time to schedule such inspections. A copy of all Special Inspection reports shall be maintained at the job site and made available upon request to the Authority Having Jurisdiction and the project Engineer of Record. STATEMENT OF SPECIAL INSPECTION Special inspection to be provided per IBC 1705 for materials, systems, components and work performed are as follows: C = Continuous Special Inspection P = Periodic Special Inspection SOILS AND FOUNDATION Provide Special Inspection for the following to determine compliance with the Geotechnical Report and the Construction Documents: Verify Footing Bearing Capacity Verify Excavations are to proper depth and have reached proper material Classification and Testing of Compacted Fill Materials Prior to the placement of Compacted Fill, observe subgrade and verify the site has been prepared properly Verify use of proper materials, densities and lift thicknesses during placement and compaction of fill IBC 1705.6 IBC 1705.6 IBC 1705.6 IBC 1705.6 IBC 1705.6 P P P P C 1. Compliance with approved submittals TMS 602-16 Section 1.5 P X 2. Verify f'm prior to construction TMS 602-16 Section 1.4B P X 3.Observe preparation of grout and mortar specimens and/or prism TMS 602-16 Section 1.4B.2.a.3, 1.4B.2.b.3, 1.4B.2.c.3, 1.4B.3, 1.4B.4 P X MASONRY - LEVEL 2 System or Material Code Reference Frequency Required a. Sample panel construction TMS 602-16 Section 1.6D P X b. Proportions of site-prepared mortar TMS 602-16 Section 2.1, 2.6A P X c. Construction of mortar joints TMS 602-16 Section 3.3B P X a. Grout space TMS 602-16 Section 3.2D & 3.2F P X b.Grade, type and size of reinforcement, connectors and anchor bolts TMS 602-16 Section 3.4 & 3.6A P X c.Placement of reinforcement, connectors and anchor bolts TMS 602-16 Section 3.2E & 3.4 TMS 402-16 Section 6.1, 6.3.1, 6.3.6 & 6.3.7 P X d. Proportions of site-prepared grout TMS 602-16 Section 2.6B P X e. Construction of mortar joints TMS 602-16 Section 3.3B P a. Slump Flow and Visual Stability Index TMS 602.16 Section 1.5 & 1.6.3 P X b. Size and location of structural elements TMS 602-16 Section 3.3F P X c. Type, size and location of anchors and details of anchorage of masonry to structural members, frames or other construction TMS 402-16 Section 1.2.1(e), 6.2.1 & 6.3.1 P X d. Preparation, construction, and protection of masonry during cold weather (below 40 degrees) or hot weather (above 90 degrees) TMS 602-16 Section 1.8C & 1.8D P X e. Placement of grout TMS 602-16 Section 3.5 C X 4.Verify as Masonry Construction Begins 5.Verify Prior to Grouting 6.Verify During Construction a. Fabrication shop compliance with IBC 1704.2.5 including completeness and adequacy of quality control procedures unless the fabricator meets the approval requirements of IBC1704.2.5.1 AISC 360 Chapter M P X b. Fabrication of Structural Elements IBC 1704.2.5, AISC 360 Chapter M P X c. Material Verification of Structural Steel IBC 1705.2.1, AISC 360 A3.1a P X d. Material Verification of Cold Formed Steel Deck IBC 1705.2.2, SDI QA/QC 2017 P X e.Material Verification of High Strength Bolts, Nuts and Washers AISC 360 A3.3 P X f.Material Verification of Anchor Rods and Threaded Rods AISC 360 A3.4 P X a. Welding Procedure Specification and Consumables AISC 360 A3.5 & N.5.4 P X b. Welder Qualifications AISC 360 N.5.4 P X c. Single Pass Fillet Welds 5/16” and smaller AISC 360 N.5.4, AWS D1.1 Section 6 P X d.Groove welds including joint preparation, dimensions, backing, etc.AISC 360 N5.4 P X a. Installation of Composite Slab Decking ICC Evaluation Report, SDI QA/QC 2017 P X c. Welding of Floor and Roof Decking AWS D1.3 P X a.X 1.X 2.X f.X e.X b.X Proprietary Moment Resisting Frame Connections IBC 1705.1.1 & 2204 P Material Verification of Reinforcing Steel for Welding ACI 318 26.6.1.2 & AWS D1.4 P Complete and Partial Penetration Groove Welds AISC 360 N.5.4, AWS D1.1 Section 6 C Multipass Fillet Welds and Single Pass Fillet Welds greater than 5/16”, Plug and Slot Welds AISC 360 N.5.4, AWS D1.1 Section 6 C Pretensioned High Strength Bolts using calibrated wrench method or turn-of-nut method without match marking AISC 360 Table N5.6-2 C STRUCTURAL STEEL System or Material Code Reference Frequency Required Pretensioned High Strength Bolts using direct tension indicator washers or twist-off heads AISC 360 M2.5 & N5.6 P 3.Fabrication 4.Welding g. Welding of Stair and Railing Systems AWS D1.1 Section 6 P 5.High-Strength Bolting 6.Composite Construction b. Installation of Roof Decking ICC Evaluation Report, SDI QA/QC 2017 P X e.Placement & installation of Headed Studs with automatic timed stud welding machine AWS D1.1 Section 7 P d.XWelding of Reinforcing Steel ACI 318 26.6.4 & AWS D1.4 P f.Placement & installation of Headed Studs with hand welding AWS D1.1 Section 7 C Welding Procedure Specification and Consumables AWS D1.3 P Welder Qualifications AWS D1.3 P Cold formed roof and floor deck welding AWS D1.3 Welded framing connections AWS D1.3 Cold-formed steel trusses spanning 60’ or greater IBC 1705.2.4 COLD FORMED STEEL System or Material Code Reference Frequency Required 1. 2. 3. 4. 5. X X X X P P P Fabrication of prefabricated structural elements IBC 1704.2.5 P Prefabricated Wood Shear Walls IBC 2306.3 & ICC Report P WOOD 1.X System or Material Code Reference Frequency Required 2. 3. X X Fabrication of high-load diaphragms: - Verify panel grade and thickness. - Verify nominal size of framing members at adjoining panel joints. - Verify nail or staple diameter and length, number of fastener lines and spacing between fasteners at each line and at edge margins. IBC 1705.5.1 & 2306.2 P Verification of the installation of temporary and permanent restraint bracing for individual trusses spanning 60’ or greater IBC 1705.5.2 P4. Structural steel of the Seismic Force Resisting Systems in structures assigned to SDC B, C, D, E or F (excluding steel structures in SDC B or C designed with R=3) IBC 1705.12.1.1 AISC 341-16 Tables J6-1, J6-2 and J6-3 P Structural steel elements of the Seismic Force Resisting Systems including struts, collectors, chords in structures assigned to SDC B, C, D, E or F (excluding steel structures in SDC B or C designed with R=3) IBC 1705.12.1.2 AISC 341-16 Tables J6-1, J6-2 and J6-3 P High Strength Bolt Installation of the Steel Seismic Force Resisting Systems in structures assigned to SDC C, D, E or F (excluding steel structures in SDC C designed with R=3) AISC 341-16 Tables J7-1, J7-2 and J7-3 P Reduced Beam Section in steel moment resisting frames AISC 341-16 Table J8-1 P Protected Zones in steel seismic force resisting systems AISC 341-16 Table J8-1 P Anchorage of storage racks 8’ in height and greater in structures assigned to SDC D, E or F IBC 1705.12.7 ASCE 7 Section 15.5.3 P Cold Formed Steel IBC 1705.12.3 P For screw attachment, bolting, anchoring and other fastening of components within the seismic force resisting system including shear walls, braces, diaphragms, collectors and hold-downs. Structural Wood IBC 1705.12.2 CField gluing of diaphragm and shear wall elements of the seismic force resisting system IBC 1705.12.2 P Nailing, bolting, anchoring and other fastening of elements of the seismic force resisting system including shear walls, diaphragms and chords, collectors, braces, shear wall anchorage and holdowns (not required when fastener spacing of sheathing > 4") Architectural Components IBC 1705.12.5 P Erection and anchorage of exterior cladding, interior and exterior veneer weighing more than 5 psf in structures assigned to SDC D, E & F IBC 1705.12.5 P Erection and anchorage of interior nonbearing walls weighing more than 15 psf in structures assigned to SDC D, E & F IBC 1705.12.5 P Erection and anchorage of exterior cladding, interior and exterior nonbearing walls, and interior and exterior veneer exceeding 30' in height above grade in structures assigned to SDC D, E & F IBC 1705.12.5.1 PAnchorage of access floors in structures assigned to SDC D, E & F ASCE7 Section 13.5.6 PInstallation and anchorage of suspended ceiling systems ASCE7 Section 13.5.1 P Installation, mounting and other seismic restraints for designated architectural systems and their components Electrical Components IBC 1705.12.6 P Anchorage of electrical equipment for emergency and standby power systems in structures assigned to SDC C, D, E & F IBC 1705.12.6 PAnchorage of all electrical equipment in structures assigned to SDC E & F IBC 1705.12.6 P Installation and anchorage of piping systems designed to carry hazardous materials and their associated mechanical units in structures assigned to SDC C, D, E & F IBC 1705.12.6 P Installation and anchorage of ductwork designed to carry hazardous materials in structures assigned to SDC C, D, E & F Mechanical Components IBC 1705.12.6 P Installation and anchorage of vibration isolating systems in structures assigned to SDC C, D, E & F where the Construction Documents require a nominal clearance of ¼” or less between the equipment support frame and the restraint Minimum installation clearance of components, including duct work, piping systems and their structural supports where automatic fire sprinkler systems without flexible hose fittings are installed in structures assigned to SDC C, D, E & F IBC 1705.12.6.6 P SPECIAL INSPECTIONS FOR SEISMIC RESISTANCE a.X System or Material Code Reference Frequency Required X X X X X X X X X X X X X b. c. d. e. f. a. b. a. b. c. d. e. f. a. b. a. b. c. d. Structural Steel1. 2. a.During welding of elements of the seismic force resisting system. b.IBC 1705.12.3 P 3. 4. 5. 6. TESTING FOR SEISMIC RESISTANCE System or Material Code Reference Required Structural steel in the seismic force resisting system of buildings and structures assigned to SDC B, C, D, E or F (not required if R=3 system)IBC 1705.13.1.1 Structural steel elements including struts, collectors and chords in the seismic force resisting system of buildings and structures assigned to SDC B, C, D, E or F (not required if R=3 system) IBC 1705.13.1.2 Document all accepted and rejected connections of the seismic resisting system IBC 1705.13.1 AISC 341 J7 Provide MT testing of the column k-area of the web where welding of doubler plates, continuity plates or stiffeners has been performed. IBC 1705.13.1 AISC 341 Table J6.3 Provide UT testing on 100% CJP groove welds in materials 5/16” and greater (For Ordinary Moment Frames, only the demand critical welds need to be tested) IBC 1705.13.1 AISC 341 J6.2a Provide MT testing on 25% of all beam-to-column CJP groove welds in materials 5/16” and greater (For Ordinary Moment Frames, only the demand critical welds need to be tested) IBC 1705.13.1 AISC 341 J6.2a Provide UT testing of base metal thicker than 1 ½” loaded in tension in tee and corner joint where the connected material is thicker than ¾” IBC 1705.13.1 AISC 341 J6.2c Provide MT testing of thermally cut surfaces of beam copes and access holes in welded splices and connection when the flange thickness exceeds 1 ½” for rolled shapes or when the web thickness exceeds 1 ½” for built-up shapes IBC 1705.13.1 AISC 341 J6.2d Provide MT testing of any weld and adjacent area of the reduced beam section (RBS) cut surface that has been repaired by welding or on the base metal of the RBS cut surface if a sharp notch has been removed by grinding IBC 1705.13.1 AISC 341 J6.2e Provide MT testing at the end of welds where weld tabs have been removed IBC 1705.13.1 AISC 341 J6.2f X X X X X X X X X X 1. 2. a. b. c. d. e. f. g. a. 3.Structural Steel 4.High Strength Bolting 737 BISHOP STREET, SUITE 1860 HONOLULU, HI 96813 808-352-5299 OWNER: 523 EAST THIRD AVENUE SPOKANE, WA 99202 P 509.323.9292 F 509.747.7115 HOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 99216SPECIAL INSPECTIONS & TESTING S003 FSC PROJECT NO. 21012 PERMIT SET 5/31/2024 GL8 Mirabeau Point, LLC 10909 E. Pierce Lane Spokane, WA 99206 (509) 919-0901 Revision Schedule Number Description Date T.O.F.T.O.F. FIN SLAB T.O.F. T.O.F.T.O.F. FIN SLAB T.O.C. T.O.S.FTGDEPTHTYP1" CLRSEENOTE 3NOT PASSPIPES SHALLMIN3 1/2"MIN.4"MIN6"NOTE 3 SEE MIN 9" MIN 1'-6"TYP1" CLR1 1/2 1 TYP PIPE IN SLEEVE CONC FDN STEM WALL DEPTHFTGTYP PIPE IN SLEEVE MONOLITHIC CONC POUR WITH FTG OR 1000-PSI MIN CDF NO EXCAVATION BELOW THIS LINE PARALLEL TRENCH EXCAVATION NOTES: 1. NO PIPES, CONDUIT, ETC. SHALL PASS THROUGH OR UNDER COLUMN PAD FOOTINGS. 2. FOR PIPES, CONDUIT, ETC. PASSING WITHIN THE FOOTING THICKNESS, STEP FOOTING DOWN AS REQ'D TO PASS THRU STEM WALL. 3. VERTICAL & HORIZONTAL SPACING BETWEEN ADJACENT PIPES SHALL BE 1 1/2xLARGEST SLEEVE DIAMETER, BUT NOT LESS THAN 6". 4. FOR PIPES MORE THAN 3'-0" BELOW FOOTING, COMPACT BACKFILL OVER PIPE TO MINIMUM 90% AND OMIT THICKENED CONC SECTION.SEENOTE 4UNLESS NOTED OTHERWISE IN GEOTECH REPORT BAR SIZE REGULAR BARS TOP BARS REGULAR BARS REGULAR BARS TOP BARS TOP BARS HOOKED BARSf'c = 3000 PSI f'c = 4000 PSI f'c = 5000 PSI 3000 PSI 4000 PSI 5000 PSI 9"7"7" 11"10"9" 14"12"11" 17"15"13" 19"17"15" 22"19"17" 25"22"19" 28" 24"22" 31"27"24" #3 #4 #5 #6 #7 #8 #9 #10 #11 Ld 17"22"15"19"13"17" SPLICE 22"28"19"24"17"22" 22"17"25"19"29"22"Ld SPLICE Ld SPLICE Ld SPLICE Ld SPLICE Ld SPLICE Ld SPLICE Ld SPLICE Ld SPLICE 29" 37"25"32"22"29" 28"22"31"24"36"28" 36"47"31"40"28"36" 33"43"29"37"26"33" 43"56"37"48"33"43" 48"63"42"54"37"49" 63"81"54"70"49"63" 55"72"48"62"43"55" 72"93"62"80"55"72" 62" 81"54"70"48"63" 81"105"70"91"63"81" 70"91"61"79"54"70" 91"118"79"102"70"91" 78"101"67"87"60"78" 101"131"87"113"78"101" (Ldh) NOTES: 1. TABULATED VALUES ARE BASED ON ACI 318-14 FOR GRADE 60 UNCOATED REINFORCEMENT AND NORMAL-WEIGHT CONCRETE. 2. TOP BARS ARE HORIZONTAL BARS WITH MORE THAN 12" OF FRESH CONCRETE CAST BELOW THE BARS. 3. TABULATED VALUES REQUIRE THE FOLLOWING: CLR COVER > 1db BAR SPACING > 2db (BEAMS & COLUMNS) > 3db (ALL OTHER MEMBERS) 4. SPLICE LENGTH OF DIFFERENT SIZED BARS SHALL BE THE LARGER OF THE FOLLOWING: A. Ld OF LARGER BAR B. SPLICE LENGTH OF SMALLER BAR CRITICAL SECTION (COLD JT) CRITICAL SECTION (COLD JT) Ld Ldh SPLICE LENGTH SPCGBARSTD DEVELOPMENT HOOK DEVELOPMENT LAP SPLICE 90° HOOK 180° HOOK PRIMARY REINFORCEMENT STIRRUPS, TIES & CROSSTIES DD D D #3 - #5 : D = 4 db #6 - #8 : D = 6 db #3 - #5 #6 - #8 D D D D D D DD DD db = BAR DIAMETER D = INSIDE BEND DIAMETER (INCLUDING SPRINGBACK) 4 db 2½" MIN 12 db#3 - #8 : D = 6 db #9 - #11 : D = 8 db 3" MIN6 db 3" MIN6 db 3" MIN 6 db 12 db 3" MIN6 db 3" MIN6 db2½" MIN 4 db 1 6 MIN TYP VERT BARS SPLICELENGTHPLAN - SINGLE CURTAIN ALT SIDES SPLICE LENGTH SPLICELENGTHSPLICE LENGTH SPLICELENGTHPLAN - DOUBLE CURTAIN STD HOOK NOTE 3 CROSS WALL NOTE 3 STD HOOK CROSS WALL STD HOOK 2 VERT BARS MIN 2 VERT BARS MIN NOTES: 1. CORNER BARS SHALL MATCH SIZE & SPACING OF HORIZONTAL REINFORCEMENT, UNO. CORNER BARS AT INTERSECTING WALLS SHALL MATCH HORIZONTAL REINFORCEMENT OF CROSS WALL. 2. SPLICE LENGTH SHALL BE PER TYPICAL LAP-SPLICE SCHEDULE FOR TENSION REINFORCEMENT. 3. PROVIDE ¾" CHAMFER AT OUTSIDE WALL CORNERS NOT IN CONTACT WITH SOIL. SPLICE LENGTH SPLICE LENGTH SPLICELENGTHCOMPACTED BASE NOTES: 1. SEE ARCHL DRAWINGS FOR VAPOR BARRIER REQUIREMENTS. MINIMIZE VAPOR BARRIER PENETRATIONS WITH FORM STAKES, NAILS, SPIKES OR OTHER CONSTRUCTION DEVICES TO THE FULLEST EXTENT PRACTICAL. 2. SEE GENERAL STRUCTURAL NOTES FOR SLAB JOINT LAYOUT AND FIBER REINFORCEMENT REQUIREMENTS. 3. SEE GEOTECHNICAL REPORT FOR COMPACTED BASE AND PREPARED SUB BASE REQUIREMENTS. 4. SLABS POURED DIRECTLY ON VAPOR BARRIER MAY TAKE LONGER TO CURE THAN SLABS NOT IN DIRECT CONTACT WITH VAPOR BARRIER. 5. WHEREVER POSSIBLE, ALIGN JOINTS WITH RE- ENTRANT SLAB CORNERS AND INTERIOR COLUMNS. 6. SEE ARCHL DRAWINGS FOR JOINT SEALANT REQUIREMENTS. 7. AT CONTROL JOINTS, SAWCUT ALONG SHORT DIRECTION OF POUR FIRST. FOR EARLY-ENTRY DRY-CUT SAWS, USE AS SOON AS POSSIBLE WITHOUT CAUSING RAVELING OF CONCRETE EDGES. PREPARED SUB BASE PUNCTURE RESISTANT VAPOR BARRIER SAWCUT CONTROL JOINT FORMED CONSTRUCTION JOINT TSEALANT WELL (1/8" TO 1/4" WIDTH) TRUE STRAIGHT LINE LOAD-TRANSFER DOWELS AT MID-DEPTH (SEE SCHED) TRUE STRAIGHT LINE SAWCUT JOINT (1/8" TO 1/4" WIDTH)T/43/4"SEE PLANDSEEPLANMIN 1.5xH CONC WALL AS OCCURS WALL REINF MATCH WALL REINF 2'-0" MAXHFTG REINF SEE PLAN MATCH FTG REINF STEEP AS POSSIBLE 3" MI NMIN D SEE PLAN S S DEVELOPMENT LENGTH, SEE SCHED LAP SPLICE, SEE SCHED * ** EA END ** * ** * PLAN - ISOLATION JT ℄COL & FTG SEE PLANS FOR FTG SIZE AND REINF 'X' = 1 1/2" UNO = 1 3/4" @ 7/8"ø & 1"ø AR BASE PL W/ 4-¾"ø AR IN OVERSIZE HOLES ON 1½" GROUT (UNO) - SEE AR SCHED S JS JS JS J SLAB JOINTS ISOLATION JOINT USING SQUARE OR ROUND FORM SEE PLAN HSS COL CLR3"MIN2" CLRUNO FILL ISOLATION JOINT W/ CONC TO MATCH ADJACENT SLAB t SEE SCHED X X X XB * BASE PL CAPACITY BASED ON AISC STEEL DESIGN GUIDE #1, 2ND EDITION, ASSUMING RIGID PLATE ON A PEDESTAL. COLUMN DIA OR LEAST WIDTH B ≤3.5" BASE PL 5/8" THICK WELD SIZE (t) 1/4" ASD LOAD CAPACITY * 40 KIPS B ≤4"3/4" THICK 1/4" 65 KIPS B ≤5"7/8" THICK 5/16" 100 KIPS B ≤8"1 1/8" THICK 260 KIPS B ≤10"1 1/4" THICK 350 KIPS SQ OR RECT HSS ROUND HSS 8"5/16" 5/16" B ≤6"1" THICK 5/16" 155 KIPS MIN 2½"MIN2½"B 2-#4x3'-0" 1½" CLR FROM TOP SURFACE S J S JSLAB JOINT OR EDGE OR RECESS RE-ENTRANT CORNER OR SLAB OPENING DISCONTINUOUS JOINT NOTES: 1. SEE GENERAL STRUCTURAL NOTES AND TYPICAL DETAILS FOR JOINTING PARAMETERS AT SLABS ON GRADE. ALSO SEE ARCH'L DRAWINGS FOR SPECIFIC JOINT LOCATIONS. 2. RE-ENTRANT CORNERS AND DISCONTINUOUS JOINTS SHALL BE AVOIDED IF POSSIBLE. 2" 2"NOTES: T.O.F. OR STRAIGHT ROD W/ HEAVY HEX NUT (THREAD EA END) HEADED BOLT ASTM A563 HEX NUT & ASTM F844 WASHERS OR PL WASHERS PROJEMBEDMENTBOLT OR ROD LENGTHGROUTNON-SHRINK EQ3/16 TACK BOLT/ROD SIZE BASE PL HOLE SIZE MINIMUM EMBED (UNO) MINIMUM WASHER 1/2"ø 1"ø 5"ASTM F844 ASTM F8446" 8" 8" 9" 1 1/8"ø5/8"ø 3/4"ø 7/8"ø 1"ø 1 5/16"ø 1 9/16"ø 1 7/8"ø PL1/4 x 2" PL5/16 x 2 1/2" PL3/8 x 3" 1. HEADED BOLTS AND STRAIGHT RODS SHALL BE ASTM F1554 (GRADE 36, UNO). ASTM A307 HEADED BOLTS SHALL NOT BE USED. 2. HEADED BOLTS OR STRAIGHT RODS CAN BE USED INTERCHANGEABLY AT THE CONTRACTOR'S OPTION. 3. PLATE WASHERS SHALL BE ASTM A36 W/ HOLES THAT ARE 1/16" LARGER THAN BOLT/ROD DIAMETER. 4. SQUARE OR CIRCULAR WASHERS MEETING THE SIZE SHOWN ARE ACCEPTABLE. 5. GALVANIZE AT EXPOSED EXTERIOR CONDITIONS. SLAB DEPTH (T) ROUND BAR DIAMOND PLATE SIZE SPACING SIZE SPACING 4"½"⌀x10"16" OC ¼x4½x4½ 18" OC 4"<T≤6" ¾"⌀x10"12" OC ¼x4½x4½ 18" OC 1"⌀x13"3/8x4½x4½ 18" OC 1¼"⌀x15"¾x4½x4½ 20" OC 6"<T≤8" 8"<T≤11" 12" OC 12" OC ROUND BAR NOTES: 1. PROVIDE SMOOTH STEEL DOWELS W/ SAWN & DEBURRED END EDGES. GREASE OR WRAP ONE END TO PREVENT BOND. 2. DOWELS SHALL BE SUPPORTED SO AS TO REMAIN LEVEL AND PERPENDICULAR TO JOINT LINE. 3. DOWELS SHALL BE PLACED NO CLOSER THAN 12" FROM JOINT INTERSECTIONS. EITHER ROUND-BAR OR DIAMOND-PLATE DOWELS MAY BE USED AT CONTRACTOR'S OPTION. DIAMOND PLATE NOTES: 1. DIAMOND-DOWEL SYSTEM SHALL BE PROVIDED BY PNA CONSTRUCTION TECHNOLOGIES OR APPROVED EQUIVALENT. 2. INSTALL DOWELS AS RECOMMENDED BY MANUFACTURER. DOORS & STOREFRONT RECESS @ COORD SETBACK AS OCCURS W/ ARCHL & STRUC DTLS #4 SLAB DWLS @ 18" OC MAX (3 MIN)#4 EA END 2'-6" PLAN #4 HORIZ STEM WALL 12"2'-6"1 1 SLAB DWLSSECTION EXTR CONC WALK @ DOORS BY OTHERS (PROVIDE 1/2"øx10" SMOOTH DWLS @ 12" OC)UNO8"1 1/2"CLR2"F.O.C. EXTEND ALL VERT BARS INTO SLAB @ DOORS (FOR DBL MATS, EXTEND VERT BARS ON INSIDE FACE ONLY) 2-#4 HORIZ, UNO RECESSED CONC STEM WALL W/ REINF PER FDN DETAILS SLAB ON GRADE SEE PLAN FOR THICKNESS & REINF NOTES: 1. SEE MECH PLANS FOR PAD THICKNESS, DIMENSIONS, AND LOCATIONS. REINFORCE PAD W/ #3 @ 12" OC EA WAY, UNO (#4 @ 12" OC FOR SLABS > 5½"). 2. PAD FOOTPRINT SHALL BE AT LEAST 4" GREATER IN ALL DIRECTIONS THAN SUPPORTED EQUIPMENT, UNLESS NOTED OTHERWISE IN MECH DWGS. #3 DOWEL @ 12" OC TYP @ PERIMETER, DRILL & SET IN ADHESIVE 3 "EQ MIN3½"2½" 6" TYP ¾" CHAMFER, TYP 737 BISHOP STREET, SUITE 1860 HONOLULU, HI 96813 808-352-5299 OWNER: 523 EAST THIRD AVENUE SPOKANE, WA 99202 P 509.323.9292 F 509.747.7115 HOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 99216TYPICAL DETAILS - CONCRETE S004 FSC PROJECT NO. 21012 PERMIT SET 5/31/2024 GL8 Mirabeau Point, LLC 10909 E. Pierce Lane Spokane, WA 99206 (509) 919-0901 SCALE:NTS1TYPICAL PIPE AND/OR CONDUIT CLEARANCES AT FOUNDATION 2150 000-0002 SCALE:NTS3TYPICAL DEVELOPMENT AND LAP-SPLICE LENGTHS FOR TENSION REINFORCEMENT IN CONCRETE, UNO 3200 000-0003 SCALE:NTS6TYPICAL REBAR BENDING DETAILS 3200 101-0003 SCALE:NTS7TYPICAL CONCRETE WALL REINFORCING @ INTERSECTION, CORNER & BAR SPLICE 3200 101-0001 SCALE:NTS9TYPICAL CONCRETE SLAB ON GRADE W/ FIBER REINFORCEMENT 3346 102-0001 SCALE:NTS12TYPICAL STEPPED FOOTING 3200 001-0001 SCALE:NTS13TYPICAL FOOTING AND BASE PLATE AT INTERIOR HSS COLUMNS 3346 000-0007 SCALE:NTS15 TYPICAL REINFORCING AT RE-ENTRANT CORNERS AND DISCONTINUOUS JOINTS IN EXPOSED SLABS ON GRADE 3346 102-0002 SCALE:NTS17TYPICAL ANCHOR ROD (AR) REQUIREMENTS 3346 000-0009 SCALE:NTS11 TYPICAL SCHEDULE FOR LOAD-TRANSFER DOWELS AT SLAB-ON-GRADE CONSTRUCTION JOINTS 3200 000-0002 SCALE:NTS19TYPICAL SLAB EDGE AT EXTERIOR DOORS & STOREFRONT, UNO 3346 102-0000SCALE:NTS16TYPICAL INTERIOR EQUIPMENT PAD AT SLAB ON GRADE 3346 000-0003 Revision Schedule Number Description Date T.O.PL SEE ARCH NOTES: 1. NAILS SPECIFIED IN STRUCTURAL DRAWINGS AND NOTES REFER TO "COMMON" TYPE NAILS (TYPICAL, UNO). 2. NAILS THAT MATCH ONE OF THE TWO "NAIL DIMENSIONS" ARE NOT ACCEPTABLE. 3. FOR NAILING NOT SHOWN IN THE CONSTRUCTION DRAWINGS, USE "COMMON" NAILS AS INDICATED IN THE IBC FASTENING SCHEDULE. LENGTH (L)DIAMETER (D) "COMMON" NAIL DESIGNATION NAIL DIMENSIONS NAIL SIZE REQUIREMENTS 6d 0.113"2" 8d 0.131"2-1/2" 10d 0.148" 12d 0.148" 16d 0.162" 20d 0.192" 3" 3-1/4" 3-1/2" 4" NAIL SPACING REQUIREMENTS 'DIMENSION': DESCRIPTION 'A': EDGE DISTANCE 2.5D (1" MIN) 'B': SPACING BETWEEN ROWS 'C': SPACING BETWEEN NAILS IN A ROW 'D': END DISTANCE 5D (1-1/2" MIN) 15D (2-1/2" MIN) 15D (2-1/2" MIN) 'D''B''A'FRAMING MEMBERWIDE FACE OF'C'SEE NOTE 4 2x DIAMETER OR LARGEST HOLE (MIN) TO EDGE 1" MIN SEE PLAN 2x WALL DISTEDGEMAX HOLE SIZE SEE TABLE 12" MIN NOTES: 1. VERIFY ALL PLUMBING WALL LOCATIONS W/ ARCHL DRAWINGS. 2. PLACE AN ADDITIONAL STUD BELOW JOIST BEARING LOCATION ADJACENT TO HOLE IN TOP PLATE. 3. STRUCTURAL WALLS INCLUDE LOAD BEARING WALLS, SHEAR WALLS, AND EXTERIOR WALLS. 4. IF LARGER DIAMETER HOLES ARE DESIRED IN TOP PLATES OF SHEAR WALLS, CONTACT EOR FOR REINFORCEMENT OPTIONS. 5. BUILT-UP STUDS AT HEADERS/BEAMS AND AT HOLDOWNS. 6. HOLES ARE NOT ALLOWED IN THE MIDDLE 1/3 OF THE STUD HEIGHT WITHOUT PRIOR APPROVAL FROM THE EOR. 7. NOTCHING OF STUDS AND/OR PLATES IS NOT ALLOWED WITHOUT PRIOR APPROVAL OF THE EOR. 8. HOLE DIAMETER IN STRUCTURAL WALL STUDS CAN BE INCREASED 50% IF STUDS ARE DOUBLED, WITH NO MORE THAN TWO CONSECUTIVE DOUBLE STUDS. WALL STUDS MAX DRILLED HOLE SIZE 2x4 1"⌀ STRUCTURAL WALLS3 BUILT-UP STUDS3 NON-STRUCT WALLS STUD SIZE 7/8"⌀2"⌀ 2x6 2"⌀1-3/8"⌀3-1/4"⌀ 2x8 3"⌀1-3/4"⌀4-1/4"⌀ STUDS MAX DRILLED HOLE SIZE TOP & BOT PLATES PLATE SIZE SHEAR WALLS OTHER WALLS MIN EDGE DISTANCE 2x4 1"⌀1-1/2"⌀1" 2x6 2"⌀2-1/2"⌀1-1/2" 2x8 3"⌀3-1/4"⌀2" TOP & BOT PLATES (SHEAR PLATES) EQ EQ MAX 1/2" MAX 1/2" STD CUT WASHER IF PL WASHER IS SLOTTED PL WASHER W/ OPTIONAL DIAGONAL SLOT NOTE: OPTIONAL DIAGONAL SLOT IN PL WASHER SHALL BE NO WIDER THAN 3/16" OVER BOLT DIAMETER W/ MAX LENGTH OF 1-3/4" PL WASHER 1/4x3x0'-3" @ 2x4 STUDS ALT: SIMPSON BP5/8-3 OR BPS5/8-3 PL1/4x3x0'-4 1/2" @ 2x6 STUDS ALT: SIMPSON BPS5/8-6 PLAN 4'-0" MIN LAP W/ 8-16d 16d EA SIDETYP 16d @ 16" OC PLATE SPLICE TO OCCUR OVER STUDS, TYP ℄COL CONDITION @ WALL CORNERS 2x STUD EA SIDE 1/2"⌀THREADED ANCHOR STUD (TAS) @ 24" OC TYP EA 2x STUD (ALT: SIMPSON TBP/TF SCREWS @ 12" OC) HSS COLUMN SEE SCHED 2x FULL-HT STUDS SEE SCHED 2x CRIPPLE STUDS 2-16d MIN EA SIDE INTO HEADER SILLS DBL TOP PLATE HEADER SEE PLAN CONT 2x SILL @ WINDOWS (DBL 2x @ OPNGS 8'-0" & WIDER, UNO) 16d SINKER @ 16" OC TYP 2-16d MIN EA SIDE INTO HEADER PROVIDE CRIPPLE STUDS TO MATCH JACK STUDS ABOVE FLOOR JOIST 1/2" GAP SIMPSON DTC TRUSS CLIP EA SIDE @ 8'-0" OC MAX STUD WALL (WOOD OR STEEL) FLOOR JOIST 2-10d EA END (TYP) STUD WALL (WOOD OR STEEL) SIMPSON DTC TRUSS CLIP EA SIDE 1/2" GAP 2x6 @ 8'-0" OC MAX (NOTCH @ JOIST EA END) JOIST PERPENDICULAR TO WALL JOIST PARALLEL TO WALL 2x8 WEB STIFFENERS EA SIDE W/ 5-10d NAILS- INSTALL PER MFRS INSTRUCTIONS ∠3x3x1/4x0'-6" W/ 2-5/8"⌀ BOLTS TO JOIST (WASHERS REQD) HANGER ROD THRD EA END - MAX LOAD 200# PER ROD 'I' JST 2x JOIST WASHER PL1/4x3x0'-3" 2x BLKG W/ 3-16d EA END HANGER ROD THRD EA END - MAX LOAD 200# PER ROD ∠3x3x1/4x1'-0" MIN W/ 2-5/8"⌀ MB @ 9" OC 2x JOIST I-JOIST 1 1/2" 8"SHEATHING (24/0) SEE PLAN 2-2x STUDS OR 4x POST EDGE NAILING - ALL EDGES, ALL SHEETS SEE SCHEDULE 2x OR 3x SOLID BLKG @ ALL PANEL EDGES FIELD NAILING @ INTERMEDIATE SUPPORTS 12" OC TYP HOLDOWN WHERE CALLED OUT ON PLAN SILL BOLTS 2'-0" MAX 1'-3" MINMIN7"CONC STEM WALL W/ PL WASHERS SEE DETAILS PARTIAL WALL ELEVATION ELEVATION NOTES: 1. MIN EDGE DISTANCE FOR NAILS SHALL BE 3/8" 2. MIN SHEATHING SHEET SIZE SHALL BE 2'-0"x4'-0" 3. NAILS SHALL BE INSTALLED FLUSH TO SURFACE OF SHEATHING AND SHALL NOT BE OVERDRIVEN 4. NAILS SHALL BE COMMON WIRE TYPE OR APPROVED EQUAL 5. INSTALL PANELS WITH LONG DIMENSION HORIZONTAL UNO 6. PROVIDE SHEATHING AND SPECIFIED NAILING FOR THE FULL LENGTH OF WALL AS INDICATED ON THE PLANS 7. PROVIDE HOT-DIPPED GALVANIZED NAILS FOR FASTENING INTO PRESSURE TREATED SILL PLATES 8. PROVIDE EDGE NAILING FULL HEIGHT TO HOLDOWN POSTS. PROVIDE EDGE NAILING TO EACH 2x STUD OR BUILT-UP MULTI 2x HOLDOWN POSTS SHEAR WALL SCHEDULE SHEATHING & FASTENING PLATE FASTENING WALL MARK APA-RATED PLYWOOD/OSB SHEATHING (1) NAIL SIZE (2) EDGE NAIL (EN) SPACING FIELD NAIL (FN) SPACING FRAMING AT ADJOINING PANEL EDGES (4) BOTTOM PLATE NAILING TO WOOD BELOW 2-ROWS 16d @ 8" OC (5) 1 RIM BOARD OR BLKG TO PLATE BELOW 2 SILL PLATE BOLTING 5/8"⌀AB @ 24" OC P1-6 P1-4 P1-3 15/32" - ONE SIDE 15/32" - ONE SIDE 15/32" - ONE SIDE 8d 6" OC 12" OC 2x 8d 4" OC 12" OC 2x 8d 3" OC 12" OC 2x 16d @ 6" OC 16d @ 8" OC A35 @ 12" OC A35 @ 16" OC A35 @ 24" OC 5/8"⌀AB @ 32" OC 5/8"⌀AB @ 48" OC NOTES: 1. 5/8" APA-RATED FRT SHEATHING AND 10d NAILS REQUIRED AT ALL EXTERIOR SHEAR WALLS. 2. COMMON NAILS SHALL BE USED UNLESS NOTED OTHERWISE. 3. AT ADJOINING PANEL EDGES, NAILS SPACED @ 2" OC INTO A SINGLE 3x MEMBER SHALL BE STAGGERED. 4. DBL 2x STUDS SHALL BE FASTENED TOGETHER WITH 2-ROWS OF 10d COMMON NAILS @ 6" OC. 5. WHERE BOTTOM PLATE REQUIRES 2 ROWS OF NAILING, PROVIDE ADDITIONAL JOIST, RIM BOARD, OR BLKG AND STAGGER NAILS. FACE NAIL WITH 2-ROWS OF 10d @ 6" OC. 6. PANEL JOINTS ON EACH FACE TO BE OFFSET TO FALL ON DIFFERENT FRAMING MEMBERS. T.O. SHTG RIM BOARD, JOIST, OR BLKG SEE NOTE 5 CORRESPONDS TO SHEAR WALL BELOW (48" OC MAX) 1 2 2-ROWS 16d @ 4" OC (5)5/8"⌀AB @ 16" OC P2-6 P2-4 P2-3 15/32" - BOTH SIDES (6)10d 6" OC 12" OC 2x 4" OC 12" OC 2x 3" OC 2x 16d @ 3" OC 16d @ 4" OC - A35 @ 6" OC A35 @ 24" OC 5/8"⌀AB @ 16" OC 5/8"⌀AB @ 32" OC 15/32" - BOTH SIDES (6) 15/32" - BOTH SIDES (6) 5/8" - BOTH SIDES (6)P2-3-5/8 2-ROWS 16d @ 3" OC (5)5/8"⌀AB @ 12" OC 10d 12" OC 3" OC 2x - 10d 10d 12" OC HEADER WINDOW OPNG 4x6 BLKG BTWN STUDS @ STRAPS EA END 2'-6" MIN CONT SILL PER TYP DTL CONT C16 COIL STRAP TOP & BOT (NAIL OVER SHTG) PER TYP DTL 2x CRIPPLE 2-2x FULL HT JAM STUD MIN (3-2x FULL HT AS REQ'D BY TYP EXTR WALL FRMG DTL) PROVIDE STGRD EN ON ALL FULL FULL HT JAM STUD NOTES: 1. SEE SHEAR WALL SCHEDULE FOR REQUIRED FRAMING MEMBERS BASED ON WALL TYPE 2. SEE TYPICAL SHEARWALL ELEVATION FOR GENERAL FRAMING INFORMATION NOT GIVEN 3. SHEATH & NAIL ABOVE & BELOW OPENING TO MATCH SHEARWALLS ON EACH SIDE 4. CS STRAP REQ'D BOTH SIDES OF WALL AND DOUBLE SIDED (P2-x) SHEAR WALLS EDGE NAILING (EN) - ALL SUPPORTED PANEL EDGES & DIAPHRAGM PERIMETER FIELD NAILING (FN) @ INTERMEDIATE SUPPORTS APA RATED SHTG LAYOUT PROVIDE 2x 4 FLAT BLOCKING @ ALL PANEL EDGES @ AREAS IDENTIFIED AS BLOCKED PLYWOOD DIAPHRAGMS ON PLAN NOTES: 1. MIN EDGE DISTANCE FOR NAILS SHALL BE 3/8". 2. MIN SHEATHING SHEET SIZE SHALL BE 2'-0" x 4'-0". 3. NAILS SHALL NOT BE OVERDRIVEN. 4. NAILS SHALL BE COMMON WIRE TYPE OR APPROVED EQUAL. 5. LAY FACE GRAIN PERPENDICULAR TO JST/TRUSSES & STAGGER PANEL JOINTS. 6. PLY CLIPS MAY BE SUBSTITUTED FOR T & G. STUD SCHEDULE, UNO EXTERIOR WALL INTERIOR WALL OPENING WIDTH JACK STUDS KING STUDS JACK STUDS KING STUDS 1 2 1 1≤4'-0" 1 2 1 1≤5'-0" 2 2≤8'-0" 1 2 1 1≤4'-0" 2 2 1 1≤5'-0" 2 2≤8'-0" 1 2 1≤4'-0" 2 2 1≤5'-0" 2 2≤8'-0" 2 2 1≤4'-0" 2 2 1≤5'-0" 3 2 2 2≤8'-0" 2 3 2≤4'-0" 3 4 2≤5'-0" 3 5≤8'-0"5THFLR4THFLR3RDFLR2NDFLR1STFLR1 2 2 3 2 2 737 BISHOP STREET, SUITE 1860 HONOLULU, HI 96813 808-352-5299 OWNER: 523 EAST THIRD AVENUE SPOKANE, WA 99202 P 509.323.9292 F 509.747.7115 HOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 99216TYPICAL DETAILS - WOOD S005 FSC PROJECT NO. 21012 PERMIT SET 5/31/2024 GL8 Mirabeau Point, LLC 10909 E. Pierce Lane Spokane, WA 99206 (509) 919-0901 SCALE:NTS1TYPICAL NAIL SIZE REQUIREMENTS 6010 SCALE:NTS3TYPICAL HOLE GUIDELINES AT STRUCTURAL WOOD-STUD WALLS SCALE:NTS16TYPICAL STEEL PLATE WASHER AT WOOD-FRAMED SHEAR WALLS SCALE:NTS5 TYPICAL MINIMUM DOUBLE TOP-PLATE LAP AND MINIMUM SPLICE NAILING SCALE:3" = 1'-0"6 TYPICAL WOOD STUD ATTACHMENT TO COLUMN 6010 950-0002 SCALE:3/4" = 1'-0"7 TYPICAL EXTERIOR WALL HEADER & SILL FRAMING, UNO SCALE:NTS9TYPICAL NON-BEARING STUD WALL BRACING TO SOLID-WEB I-JOISTS SCALE:NTS11TYPICAL SUSPENDED MECHANICAL SUPPORT @ I-JOISTS SCALE:NTS12TYPICAL WOOD STRUCTURAL PANEL SHEAR WALL CONSTRUCTION SCALE:NTS14TYPICAL WOOD STRUCTURAL PANEL SHEAR WALL SCHEDULE SCALE:NTS17TYPICAL SHEAR WALL CONSTRUCTION WITH FORCE TRANSFER AROUND OPENINGS (WHERE NOTED ON PLANS) SCALE:NTS19TYPICAL APA RATED SHEATHED ROOF DIAPHRAGM CONSTRUCTION Revision Schedule Number Description Date T.O. SHTG FLOOR SHTG 2x6 MIN BLKG @ 48" OC MAX W/ SIMPSON LU24 HGRS EA END I-JOISTS W/ BACKER BLOCK @ HGRS NON-STRUCTURAL WALL SEE ARCH SCALE:NTS1TYPICAL NON-STRUCTURAL WALL PARALLEL WITH JOISTS 737 BISHOP STREET, SUITE 1860 HONOLULU, HI 96813 808-352-5299 OWNER: 523 EAST THIRD AVENUE SPOKANE, WA 99202 P 509.323.9292 F 509.747.7115 HOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 99216TYPICAL DETAILS - WOOD S006 FSC PROJECT NO. 21012 PERMIT SET 5/31/2024 GL8 Mirabeau Point, LLC 10909 E. Pierce Lane Spokane, WA 99206 (509) 919-0901 Revision Schedule Number Description Date T.O.B.T.O.B.T.O.B. T.O.B. T.O.B.T.O.B. T.O.B. BM SIZE TYP NO OF BOLTS SHEAR PL / KNIFE PL THICKNESS CAPACITY STIFF PL THICKNESS WELD SIZE (t) W8, W10 W12, W14 W16 W18 W21, W24 W27 W30 2 3 4 5 6 7 8 9 1/4" ** 1/4" ** 3/8" 3/8" 3/8" 3/8" 3/8" 3/8" 16.3 K 25.6 K 42.1 K 54.5 K 66.8 K 78.8 K 90.9 K 103.0 K 1/4" 1/4" 3/8" 3/8" 1/2" 1/2" 5/8" 5/8" 3/16" ** 3/16" ** 1/4" 1/4" 1/4" 1/4" 1/4" 1/4" BOLT EDGE DISTANCE & SPACING (TYP, UNO) SHEAR PL OR KNIFE PL F.O. SUPPORT (COLUMN OR EMBED PL) W BM TYP 1/2" CLR NOTES: 1. USE 3/4"ø A325 (HSB) SNUG-TIGHT AT BOLTED STEEL CONNECTIONS, UNO. SEE GENERAL STRUCTURAL NOTES FOR ADDITIONAL INFORMATION INCLUDING MATERIAL SPECIFICATIONS FOR BOLTS, WASHERS, AND NUTS. 2. AT BEAM-COLUMN CONNECTION, USE HORIZONTAL SSL HOLES IN SHEAR & KNIFE PLATES WHERE 'TYP NO. OF BOLTS' IS 6 OR GREATER. PROVIDE HARDENED STEEL WASHERS. AT 5 BOLTS OR LESS, USE EITHER STD OR HORIZONTAL SSL HOLES IN PLATES. 3. SHEAR & KNIFE PLATE CAPACITIES ARE FOR VERTICAL LOAD APPLICATIONS AND ARE FROM AISC TABLE 10-10A, 15TH EDITION, ALLOWABLE STRENGTH DESIGN (ASD). 4. SEE BRACED-FRAME DETAILS FOR ADDITIONAL REQUIREMENTS AT BEAM-COLUMN CONNECTIONS. 5. USE TYPICAL NUMBER OF BOLTS WHENEVER CONNECTION CONFIGURATION ALLOWS. COPE OR STRIP INCOMING BEAM FLANGES AS REQUIRED. ** KNIFE PLATE THICKNESS SHALL BE 3/8" WITH 1/4" WELD SIZE AT ALL BEAM DEPTHS, UNO. W33 SEE NOTE 2 TYP 1 1/2"TYP1 1/2"TYP3" t W BM W BM NOTES: 1. SEE TYPICAL BOLTED STEEL CONNECTION SCHEDULE FOR ADDITIONAL INFORMATION. 2. SHEAR PLATE CONNECTION IS ACCEPTABLE AT ALL LOCATIONS, UNO. USE KNIFE OR TEE PLATE CONNECTION ONLY WHERE INDICATED. 3. SEE TYPICAL SKEWED SHEAR PLATE DETAIL FOR SKEWED CONNECTIONS BETWEEN 17° AND 45°. 4. AT SHEAR PLATE CONNECTION, WALL THICKNESS OF HSS COLUMNS SHALL BE AT LEAST 1/4" WHEN PLATE THICKNESS IS 3/8". OTHERWISE, USE KNIFE OR TEE-PLATE CONNECTION. HSB (SEE SCHED) W BM W BM CAP PL1/4 @ T.O. COL, UNO TYP3"SHEAR PL (NOTE 4) SHEAR PLATE (DEFAULT TYPE) KNIFE PLATE (ALTERNATE TYPE) W BM W BM HSB (SEE SCHED)TYP3"BACK PL5/8 x COL WIDTH x SHEAR PL DEPTH TEE PLATE (ALTERNATE TYPE) TYP BACK PL TO COL CL COL & BM t TYP3"HSB (SEE SCHED) KNIFE PL3/8 IN SLOTTED COL SHEAR PL3/81/4 SHEAR PL TO BACK PL1/4 HSS COL HSS COLCLR 1/2" TYP 1 1/2" CLR 1/2" TYP 1 1/2" HSS COL TYP 1 1/2" CLR 1" 1 1/2"TYP 1 1/2"TYP 1 1/2"TYPTYPICAL DECK SUPPORT ANGLE AS NEEDED kW BM CL COL & STIFF PL STIFF PL EA SIDE TYP 1 1/2" t kW BM CL COL & STIFF PL STIFF PL EA SIDE TYP 1 1/2" CL COL UNO 1'-0"kW BM W BM SEE TYP BEAM SPLICE DETAIL SEE CONTINUOUS BEAM CONDITION NOTES: 1. BRG PLATE THICKNESS, "T" = SEE SCHEDULE @ RIGHT. 2. BRG PLATE WIDTH, "W" = GREATER OF (BEAM GAGE + 2 1/2") OR (COLUMN WIDTH + 1/2"). 3. SEE TYPICAL BOLTED STEEL CONNECTION SCHEDULE FOR STIFF PLATE THICKNESS AND WELD SIZE 't'. 4. AT CONTINUOUS AND CANTILEVERED BEAMS, PROVIDE BR-2 OR BR-3 BRACE (PER TYP DETAIL) UP TO DECK ON EITHER SIDE. NOT REQUIRED WHERE CANTILEVER DISTANCE IS LESS THAN 2x BEAM DEPTH. END CONDITION CONTINUOUS BEAM DISCONTINUOUS / CANTILEVER BEAM BRG PL "T"x"W" W/ 2-3/4"⌀HSB @ BEAM GA BRG PL "T"x"W" W/ 4-3/4"⌀HSB @ BEAM GA 1/4 1/4 t BOTTOM FLANGE BRACE (SEE NOTE 4) 1/2" HSS COL HSS COL HSS COL 1/2" ≤W16 ≤W24 ≤W33 > W33 BEAM SIZE BRG PLATE THICKNESS 1/2" 5/8" 3/4" 7/8" W MB W MB 1/2" CLR 1 1/2" TYP 5/16 3 SIDES (NOTE 2) BM 1/43 SIDES SPLICE PL3/8x6 1/2 W/ STD OR HORIZ SSL HOLES ℄ SPLICESEE PLAN DIMENSION SEE PLAN DIMENSION HSB (SEE SCHED)TYP3" TYP1 1/2"NOTES: 1. USE NUMBER OF BOLTS FOR SMALLER BEAM PER TYPICAL BOLTED STEEL CONNECTION SCHEDULE. 2. ADDITIONAL FIELD WELD REQUIRED AT LATERAL DRAG CONNECTIONS WHERE NOTED ON PLAN. NOTES: 1. SEE TYPICAL W BEAM TO HSS COLUMN CONNECTION DETAIL FOR ADDITIONAL INFORMATION. 2. USE EITHER KNIFE PLATE OR TEE PLATE CONNECTIONS AT BEAMS MARKED ON PLAN WITH LATERAL DRAG SYMBOL SHOWN BELOW, TYP UNO. 3. USE A COMBINATION OF KNIFE PLATE AND TEE PLATE CONNECTIONS WHEN DRAG LOADS OCCUR IN BOTH DIRECTIONS (SEE BELOW). 4. AT FLOOR BEAMS, PROVIDE PLATE-TO-BEAM WELD AFTER CONCRETE HAS BEEN PLACED ON DECKING (AS OCCURS). WELD APPLIES TO BEAM ON EACH SIDE OF COLUMN, UNO.W BM W BM KNIFE OR TEE PLATE TEE PLHSS COL KNIFE PLHSS COL PLAN SYMBOL FOR LATERAL DRAG DRAG IN BOTH DIRECTIONS DRAG CONNECTION PLAN SYMBOL KNIFE OR TEE PL 5/16 3 SIDES (NOTE 4) BM BM TYPICAL DECK SUPPORT ANGLE AS NEEDED 1/4 TYP 1 1/2" W BM kBRG PL "T"x"W" W/ 4-3/4"⌀HSB @ BEAM GA HSS COL BELOW AS OCCURS (SEE TYP DETAIL) STIFF PL EA SIDE @ COLUMN CL (USE FULL DEPTH PL IF COL ABOVE & BELOW) t HSS COL NOTES: 1. BRG PLATE THICKNESS, "T" = 1/2" @ HSS4x4 COLS & SMALLER, 5/8" OTHERWISE. 2. BRG PLATE WIDTH, "W" = GREATER OF (BEAM GAGE + 2 1/2") OR (COLUMN WIDTH + 1/2") 3. SEE TYPICAL BOLTED STEEL CONNECTION SCHEDULE FOR STIFF PLATE THICKNESS AND WELD SIZE 't'. T.O.B. HSB PER TYP BM-TO-BM DETAIL SEE TYP DETAIL FOR BM-TO-BM SHEAR PLATE CONN INCOMING W BM STIFF PL (SEE SCHED) STRIP BM FLANGE @ STIFF PL INCOMING W BM W BEAM BRG ON HSS COL (SEE TYP DETAIL)kHSS COL HSB (SEE SCHED) INCOMING BM INCOMING BM TYP 1/2" CLR t SUPPORTING BM SHEAR PL3"TYPNOTES: 1. USE SHEAR PLATE THICKNESS AND WELD SIZE 't' FOR INCOMING BEAM (SEE TYPICAL BOLTED STEEL CONNECTION SCHEDULE). 2. USE MAXIMUM NUMBER OF BOLTS IN SINGLE ROW ALLOWED BY CONFIGURATION OF EACH CONNECTION. 3. IF SCHEDULED BOLT COUNT FOR INCOMING BEAM CANNOT BE ACHIEVED IN SINGLE ROW, EXTEND SHEAR PL 3" AND ADD SECOND ROW TO ACHIEVE BOLT COUNT. NOT REQUIRED IF ONLY ONE SCHEDULED BOLT IS DROPPED.TYP1/2" CLR 1 1/2" TYP T.O. BEAM FLUSH SEE NOTE 31 1/2" HSB (SEE SCHED) HSB (SEE SCHED)3"TYP3" OCSUPPORTING BM SEE NOTE 3 INCOMING W BM INCOMING W BMSEE PLANVARIESTYP3" OCSEE PLANVARIESCLR 1/2" 1 1/2" TYP SHEAR PL 1 1/2"SHEAR PL SEE NOTE 3 CLR 1/2" TYP 1 1/2"t T.O. BEAM VERTICALLY OFFSETTYP1 1/2" 5/16 1/2 F.O. SUPPORT ANGLE 3/8" MIN BEVELED SHEAR PL 1/4 1/2 3 " ANGLE 3/8" MIN SHEAR PL 3"17° < ANGLE ≤30°30° < ANGLE ≤45° F.O. SUPPORT HSS COL 3/16 3/16 MIN 2" BRACE W/ COPED LEG (NOTE 2) SEE PLAN SEE PLAN W BEAM 3/16TYP PL BRACE (NOTE 2) PL1/4x5x0'-5" EA END (OR STIFF PL) 3/16 1½ EA END ROOF OR FLR DECK HSS4x4x1/4 BTWN JSTS TYPE BR-1 TYPE BR-2 TYPE BR-3 HSS COL 3/16EA END STIFF PL CONT OR CANTILEVER W BEAM 2 1 BRACE (NOTE 2) 3/16 1" MAX JST OR W BM (REINF JST TOP CHORD PER TYP DTL) HSS L5x3½x¼ x0'-6" (LLV) 3/16 NOTES: 1. LOCATE BRACE BR-1 ONLY WHERE SHOWN ON PLAN. LOCATE BRACE BR-2 WHERE SHOWN ON PLAN OR AT 8'-0" OC MAX, UNO. 2. BRACE COMPONENT SHALL BE SIZED AS FOLLOWS: LENGTH SIZE ≤8'-0"L3x3x1/4 >8'-0" L4x4x1/4 JST OR W BM ROOF OR FLR DECK HSS COL HSS COL NOTES: 1. "W" = GREATER OF BEAM OR COLUMN WIDTH 2. BOTTOM ANGLE CAN HAVE VERT LEG TURNED UP IF NEEDED L3x3x1/4x LENGTH "W" TOP & BOT (SEE WELDS @ LEFT)HSS BEAM HSS WINDOW SILL TYP TYP @ COL - OPTIONAL SHOP WELD HSS BEAM L4x3x3/8x LENGTH "W" TOP & BOT (LLV) 1/2" CLR 1/2" CLR TYPICAL CONDITION - BEAMS & MULLIONS (UNO)WINDOW SILL SEE ARCHL 737 BISHOP STREET, SUITE 1860 HONOLULU, HI 96813 808-352-5299 OWNER: 523 EAST THIRD AVENUE SPOKANE, WA 99202 P 509.323.9292 F 509.747.7115 HOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 99216TYPICAL DETAILS - STEEL S007 FSC PROJECT NO. 21012 PERMIT SET 5/31/2024 GL8 Mirabeau Point, LLC 10909 E. Pierce Lane Spokane, WA 99206 (509) 919-0901 SCALE:NTS1TYPICAL BOLTED STEEL CONNECTION SCHEDULE 5100 SCALE:NTS3TYPICAL W-BEAM TO HSS-COLUMN CONNECTION TYPES 5100 SCALE:NTS6TYPICAL W BEAM BEARING ON HSS COLUMN 5100 100-0003 SCALE:NTS8TYPICAL BEAM SPLICE 5100 SCALE:NTS9TYPICAL W-BEAM TO HSS-COLUMN LATERAL DRAG CONNECTION 5100 SCALE:NTS11TYPICAL HSS COLUMN BEARING ON W BEAM 5100 SCALE:NTS12TYPICAL INTERSECTING BEAMS OVER HSS COLUMN 5100 SCALE:NTS13TYPICAL BEAM-TO-BEAM SHEAR PLATE CONNECTION 5100 SCALE:NTS15TYPICAL SKEWED SHEAR PLATE BETWEEN 17° & 45° 5100 SCALE:NTS16TYPICAL COLUMN & W BEAM BRACING TYPES 6010 SCALE:NTS19TYPICAL HORIZONTAL HSS MEMBER TO HSS COLUMN CONNECTION 5100 Revision Schedule Number Description Date STEEL DECK AND ATTACHMENT SCHEDULE DECK TYPE GAGE I+/I-(IN4/FT)S+/S-(IN3/FT)PERP TO DECK FLUTES PARALLEL TO DECK FLUTES SIDE LAP ROOFFLOOR1 1/2" TYPE 'B' 3" TYPE 'N3' 1 1/2" TYPE 'B' (COMPOSITE) 2" TYPE 'W2' (COMPOSITE) 20 18 20 20 20 0.219 / 0.231 0.302 / 0.306 0.890 / 0.953 0.219 / 0.231 0.422 / 0.419 0.230 / 0.237 0.314 / 0.331 0.452 / 0.509 0.230 / 0.237 0.323 / 0.333 36/4 PATTERN 36/4 PATTERN 32/5 PATTERN 36/4 PATTERN 36/4 PATTERN 12" OC 12" OC 12" OC 12" OC 12" OC 'IP' @ 24" OC 'IP' @ 24" OC 'IP' @ 24" OC 'BP' OR 'IP' @ 24" OC 'BP' OR 'IP' @ 24" OC TYPICAL MEANS OF DECK ATTACHMENT STEEL FRAMING:1/2"Ø ARC SPOT WELDS 3/8"x1" LONG ARC SEAM WELDS (MINIMUM EFFECTIVE FUSION AREAS) WOOD FRAMING:1/4"x2 1/2" SIMPSON SDS SCREWS (SEE NOTE 5) 'BP' = BUTTON PUNCH 'IP' = INTERLOCK PUNCH (VERCO VSC2 OR EQUIV) NOTES: 1. SCHEDULE INDICATES MINIMUM REQUIREMENTS, UNO ON PLANS. 2. VERIFY DECK FINISH WITH ARCHL DRAWINGS. 3. ACOUSTICAL DECK REQUIRED WHERE NOTED ON PLANS OR ARCHL DRAWINGS. 4. WHERE PROVIDED, WELDED SHEAR STUDS CAN REPLACE A DECK WELD ON A ONE-TO-ONE BASIS. 5. WHERE DECK ATTACHES TO WOOD FRAMING, PROVIDE BUILDING PAPER BETWEEN DECK AND WOOD. UNLESS SCREWS HAVE SELF-DRILLING CAPABILITIES, PROVIDE 17/64"Ø PRE-DRILLED HOLES THROUGH DECK ONLY. 36/4 36/7 32/5 36/4 TYPE 'B' DECK TYPE 'N3' DECK TYPE 'W2' DECK DENOTES ARC SPOT WELD DENOTES ARC SEAM WELD EFFECTIVE SECTION PROPS DECK ATTACHMENT, UNO GENERAL NOTE: BUTT JOINTS SHALL ONLY BE USED WHERE LAP JOINTS CANNOT BE ACHIEVED. 1 2 4 3 STEEL DECK WF OR OWSJ WF OPEN WEB JOIST LAP JOINT BUTT JOINT BUTT JOINT OVER OWSJ KEY NOTES: PROVIDE 2" MINIMUM END LAP LOCATED ENTIRELY OVER SUPPORTING MEMBER. 1 2 3 PROVIDE 2" MINIMUM END BEARING IN ALL CASES. END GAP AT BUTT JOINTS SHALL BE MINIMIZED TO ALLOW 2" MINIMUM BEARING FOR EACH DECK PIECE. PROVIDE CONT 6"-WIDE BUTT STRIP TO MATCH DECK GAGE (GALV) W/ #12 SCREWS @ 12" OC EACH SIDE OF JOINT. 4 KEY NOTES: PROVIDE CONT 16 GAGE CLOSURE STRIP WHERE LOW DECK FLUTES CANNOT ATTACH DIRECTLY TO SUPPORTING MEMBER. 1 ATTACH CLOSURE TO SUPPORTING MEMBER PER TYPICAL DECK SCHEDULE. 2 ATTACH DECK TO CLOSURE W/ #12 SCREWS @ 12" OC. ATTACHMENT CAN BE MADE THRU LOW FLUTE OR WEB. 3 PERIMETER SUPPORT INTERIOR SUPPORT 2 3 2 3 1 STEEL DECK 1 WF 1 1/2" MIN 3" MAX GENERAL NOTE: DETAIL APPLIES ONLY WHERE LOW DECK FLUTE CANNOT BE ATTACHED DIRECTLY TO SUPPORT.NOTE: THIS DETAIL APPLIES TO A SINGLE ISOLATED PENETRATION. FOR GROUPS OF SMALL PENETRATIONS, SEE TYPICAL DETAILS FOR MEDIUM AND LARGE OPENINGS. PENETRATION SIZE OF 6" TO 12" (NOT REQ'D AT PENETRATIONS < 6") MIN 16 GA GALV SHEET EXTENDED 6" BEYOND OPNG ON ALL SIDES #12 SCREWS @ 6" OC AROUND PERIMETER 737 BISHOP STREET, SUITE 1860 HONOLULU, HI 96813 808-352-5299 OWNER: 523 EAST THIRD AVENUE SPOKANE, WA 99202 P 509.323.9292 F 509.747.7115 HOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 99216TYPICAL DETAILS - STEEL S008 FSC PROJECT NO. 21012 PERMIT SET 5/31/2024 GL8 Mirabeau Point, LLC 10909 E. Pierce Lane Spokane, WA 99206 (509) 919-0901 SCALE:NTS1TYPICAL MINIMUM REQUIREMENTS FOR STEEL ROOF AND FLOOR DECK SCALE:NTS3TYPICAL DECK END JOINTS OVER SUPPORTS SCALE:NTS4TYPICAL DECK CLOSURE PARALLEL TO FLUTES SCALE:NTS5TYPICAL SMALL PENETRATION AT ROOF DECK Revision Schedule Number Description Date -SS--SS--SS- -SS- 1 A A B C D E F G H J K L M N P 22.1 3 3.1 4 5 6 6 6.1 7 7 8 8 8.1 9 9 C.1 L.1 65'-1 1/2" 30'-6 5/8"5'-10 1/4"28'-8 5/8"131'-9 1/8"30'-0"13'-4 7/8"5'-9 7/8"9'-3"15'-0 5/8"3'-11 1/4"15'-2 3/4"8'-8 7/8"6'-1 1/4"4'-7 3/8"19'-7 1/4"6'-0"55'-11 3/8"19'-0 7/8"19'-0 3/4"19'-1"19'-0 7/8"19'-0 3/4"14'-11"19'-1 1/2"10'-9"14'-11 1/4"19'-1 1/2"19'-9 1/8"54'-3 1/2"23'-11 5/8"6'-1 1/4"24'-2 5/8"27'-9 7/8"Q 249'-11" 68'-9 1/2" 10 10 11 28'-0"0"11'-0 5/8"8'-6"8'-3 1/4"WS326 WS326 WS26 TYP @ CORRIDOR WALLS, UNO WS326 WS326 WS326 TYP @ DEMISING WALLS WS226 TYP @ EXT WALLS UNO WS326 WS326 WS326 WS326 WS326 WS226 WS226 WS226 WS28 WS28 WS28 WS326 W8x10W8x10W8x10W8x10W8x10W8x10W8x10W8x10 W8x10 W8x10 W8x10 W8x10W8x10W8x13W8x10W8x10 NOTE:SEE DETAIL X/SXXX FOR W8 STEEL HEADERS P1-4P1-4P1-4 P1-4 P2-6P2-423.5K T35.1K C23.5K T35.1K CP2-4 P1-6P2-4 P1-6P2-4 P2-4P1-4P2-4 3.3K T20.3K C3.3K T20.3K CP1-6P1-4P1-4P1-48.5K T22.3K C8.5K T22.3K CP2-3P2-4P2-4 5.6K T13.8K C5.6K T13.8K C15.6K T19.3K C15.6K T19.3K CP1-4P1-4P1-4P1-4P1-4P2-3-5/8 P2-3-5/8 P2-3 P2-3 P1-6 P1-6 FTAO STEEL MOMENT FRAME P1-4P1-43-2x8 3-2x8 3-2x8 2.8K T18.8K C2.8K T18.8K C12.3K T14.9K C21.2K T21.2K C21.2K T21.2K C4.1K T22.8K C4.1K T22.8K C10.2K T25.4K C10.2K T25.4K C10.9K T29.5K C10.9K T29.5K C16.8K T29.6K C16.8K T29.6K C8.2K T30.3K C8.2K T30.3K C9.9K T30.4K C9.9K T30.4K C2.4K T17.4K C2.4K T17.4K CHDU14-SDS2.5H D U14 -SD S2.5HDU8-SDS2.5SDS2.5HDU8-14.0K T11.6K C14.0K T11.6K C19.7K T22.5K C19.7K T22.5K C14.6K T16.9K C14.6K T16.9K C9.8K T13.6K C9.8K T13.6K C10.1K T12.7K C10.1K T12.7K C7.3K T12.2K C7.3K T12.2K CP1-610.1K T12.7K C8.1K T12.3K C1.7K T4.2K C1.7K T4.2K C4.7K T10.6K C6.8K T23.0K C4.7K T10.6K CP1-61.7K T4.2K C1.7K T4.2K CP1-62.5K T4.4K C2.5K T4.4K C6.8K T23.0K C10.0K T28.0K C6.7K T11.7K C6.7K T11.7K C5.1K T26.2K C5.1K T26.2K C1. SEE S002 FOR CONTINUOUS TIE DOWN SYSTEM NOTES. 2. ALL 1ST FLOOR LEVEL EXTERIOR WALLS TO BE SHEATHED WITH 5/8" FRT SHEATHING, INCLUDING DOUBLE SIDED SHEAR WALLS. 3. ALL 2ND FLOOR LEVEL AND ABOVE EXTERIOR SHEAR WALLS TO BE SHEATHED WITH 5/8" FRT SHEATHING, SECTIONS OF EXTERIOR WALLS NOT DESIGNATED AS SHEAR WALLS MAY BE SHEATHED WITH DENSGLASS SHEATHING MEETING THE FIRE ASSEMBLY REQUIREMENTS. 4. ALIGN STUDS ABOVE WITH STUDS BELOW AT ALL WALLS BEARING ON WALLS THAT DON'T HAVE INTERVENING RIMBOARD (EXTERIOR WALLS AND SHAFT WALLS). OVERALL PLAN NOTESSTRUCTURAL WALL SCHEDULE, UNO NOTES: 1. ALL EXTERIOR WALLS TO BE FRAMED WITH FRT STUDS, PLATES, HEADERS, AND SHEATHING. 2. SEE TYPICAL DETAIL FOR KING AND JACK STUD REQUIREMENTS. 3. SEE SHEARWALL SCHEDULE FOR ADDITIONAL REQUIREMENTS. 2x4 STUDS @ 16" OCWS24 2x6 STUDS @ 16" OC 2x8 STUDS @ 16" OC 2-2x4 STUDS @ 16" OC 2-2x6 STUDS @ 16" OC 3-2x6 STUDS @ 16" OC WS26 WS28 WS224 WS226 WS326 MIN HEADER SCHEDULE, UNO OPENING WIDTH 1st FLR -4th FLREXTERIOR WALL CORRIDOR WALL DEMISING WALL 5th FLR≤4'-0"2-2x6 2-2x6 2-2x8 ≤5'-0"2-2x6 2-2x6 ≤8'-0"2-2x8 ≤4'-0"2-2x6 2-2x6 2-2x8 3-2x6 3-2x8 2-2x8 ≤5'-0" ≤8'-0" 737 BISHOP STREET, SUITE 1860 HONOLULU, HI 96813 808-352-5299 OWNER: 523 EAST THIRD AVENUE SPOKANE, WA 99202 P 509.323.9292 F 509.747.7115 HOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 99216OVERALL FLOOR / FOUNDATION PLAN & 1ST FLOOR WALLS S101 FSC PROJECT NO. 21012 PERMIT SET 5/31/2024 GL8 Mirabeau Point, LLC 10909 E. Pierce Lane Spokane, WA 99206 (509) 919-0901 NORTHSCALE:3/32" = 1'-0" OVERALL FLOOR / FOUNDATION PLAN & 1ST FLOOR WALLS STRUCTURAL COLUMN SCHEDULE MARK COL SIZE REMARKS C444 HSS4x4x1/4 C554 HSS5x5x1/4 C556 HSS5x5x3/8 C558 HSS5x5x1/2 C664 HSS6x6x1/4 C666 HSS6x6x3/8 C756 HSS7X5X3/8 C758 HSS7x5x1/2 C8810 HSS8X8X5/8 W12x35 W12x35 Revision Schedule Number Description Date 1 A A B C D E F G H J K L M N P 1.1 22.1 3 3.1 4 5 6 6 6.1 7 7 8 8 8.1 9 9 C.1 L.1 Q 10 10 11 249'-11"133'-6"55'-11 3/8"19'-0 7/8"19'-0 3/4"19'-1"19'-0 7/8"19'-0 3/4"14'-11"19'-1 1/2"10'-9"14'-11 1/4"19'-1 1/2"19'-9 1/8"25'-8 7/8"13'-4 7/8"5'-9 7/8"9'-3"15'-0 5/8"3'-11 1/4"15'-2 3/4"8'-8 7/8"6'-1 1/4"4'-7 3/8"19'-7 1/4"6'-0"65'-1 1/2" 30'-6 5/8"5'-10 1/4"28'-8 5/8"27'-9 7/8"WS26 WS26 TYP @ EXT WALLS UNO WS26 WS26 TYP @ DEMISING WALLS, UNO WS226 WS226 WS26 TYP @ CORRIDOR WALLS UNO4'-3 1/8"WS226 OR WS28WS26 TYP @ CORRIDOR WALLS UNOWS224 WS224 LVL3 1/2x11 7/8 P1-4 P1-6P1-4 P1-49.3K T16.1K C9.3K T16.1K CP1-6 P1-6 P1-412.5K T20.1K C16.9K T21.4K CP1-4 P1-6 P1-6P2-342.5K T45.1K C42.5K T45.1K CP1-3P1-312.1K T19.1K C11.1K T18.8K C12.1K T19.1K C11.1K T18.8K CP2-341.4K T44.2K C41.4K T44.2K CP1-4 11.3K T18.9K C11.3K T18.9K CP1-3P1-4P1-4 11.2K T20.3K C11.2K T20.3K CP1-4 P1-6P1-62.5K T18.2K C2.5K T18.2K CP1-3 11.4K T20.1K C11.4K T20.1K CP1-4P1-3 11.4K T20.1K C11.4K T20.1K CP1-4 P1-4P1-4P1-311.4K T20.1K C11.4K T20.1K CP1-3 2.5K T17.2K C2.5K T17.2K CP1-311.4K T20.1K C11.4K T20.1K CP1-3 2.5K T17.2K C2.5K T17.2K CP1-4 P1-3 P1-6P1-3 P1-3P1-41.0K T18.1K C1.0K T18.1K CP1-611.4K T16.6K C11.4K T16.6K CP1-3P1-4P1-3 10.2K T16.1K C10.2K T16.1K CP1-3 10.2K T16.1K C10.2K T16.1K CP1-4 P1-310.2K T16.1K C10.2K T16.1K CP1-310.2K T16.1K C10.2K T16.1K CP1-4P1-4P1-4P1-6P1-4P1-4P1-412.5K T20.1K C16.9K T21.4K CP1-6 P1-4P1-4P1-312.3K T14.9K C12.3K T14.9K C11.7K T14.7K C11.7K T14.7K C11.8K T14.7K C11.8K T14.7K CP1-4 13.1K T16.5K C13.1K T16.5K C10.4K T16.0K C10.4K T16.0K C7.7K T10.5K C7.7K T10.5K C3.2K T17.6K C3.2K T17.6K C7.9K T17.7K C7.9K T17.7K C2.3K T18.2K C2.3K T18.2K C1.5K T6.5K C1.5K T6.5K C9.0K T11.1K C9.0K T11.1K C6.6K T10.5K C6.6K T10.5K CSHADED AREA INDICATES 2x6 FLAT BLOCKING REQ'D W/ E.N. AT ALL PANEL EDGES SHADED AREA INDICATES 2x6 FLAT BLOCKING REQ'D W/ E.N. AT ALL PANEL EDGES5.1K T13.K C5.1K T13.K C3.1K T9.9K C3.1K T9.9K C4.2K T8.6K C2.8K T7.9K C2.8K T7.9K C5.3K T8.2K C5.3K T8.2K C12.3K T14.1K C12.3K T14.1K C9.8K T11.6K C9.8K T11.6K C10.6K T13.3K C10.6K T13.3K C9.8K T11.6K C9.8K T11.6K C3.3K T5.6K C3.3K T5.6K C5.7K T8.8K C5.7K T8.8K C5.7K T8.8K C5.7K T8.8K C5.7K T8.8K C5.7K T8.8K C5.7K T8.8K C5.7K T8.8K C5.7K T8.8K C5.7K T8.8K C6.0K T8.9K C6.0K T8.9K C5.3K T8.2K C5.3K T8.2K C6.6K T8.5K C6.6K T8.5K C4.9K T8.1K C4.9K T8.1K C1. SEE S002 FOR CONTINUOUS TIE DOWN SYSTEM NOTES. 2. ALL 1ST FLOOR LEVEL EXTERIOR WALLS TO BE SHEATHED WITH 5/8" FRT SHEATHING, INCLUDING DOUBLE SIDED SHEAR WALLS. 3. ALL 2ND FLOOR LEVEL AND ABOVE EXTERIOR SHEAR WALLS TO BE SHEATHED WITH 5/8" FRT SHEATHING, SECTIONS OF EXTERIOR WALLS NOT DESIGNATED AS SHEAR WALLS MAY BE SHEATHED WITH DENSGLASS SHEATHING MEETING THE FIRE ASSEMBLY REQUIREMENTS. 4. ALIGN STUDS ABOVE WITH STUDS BELOW AT ALL WALLS BEARING ON WALLS THAT DON'T HAVE INTERVENING RIMBOARD (EXTERIOR WALLS AND SHAFT WALLS). OVERALL PLAN NOTESSTRUCTURAL WALL SCHEDULE, UNO NOTES: 1. ALL EXTERIOR WALLS TO BE FRAMED WITH FRT STUDS, PLATES, HEADERS, AND SHEATHING. 2. SEE TYPICAL DETAIL FOR KING AND JACK STUD REQUIREMENTS. 3. SEE SHEARWALL SCHEDULE FOR ADDITIONAL REQUIREMENTS. 2x4 STUDS @ 16" OCWS24 2x6 STUDS @ 16" OC 2x8 STUDS @ 16" OC 2-2x4 STUDS @ 16" OC 2-2x6 STUDS @ 16" OC 3-2x6 STUDS @ 16" OC WS26 WS28 WS224 WS226 WS326 MIN HEADER SCHEDULE, UNO OPENING WIDTH 1st FLR -4th FLREXTERIOR WALL CORRIDOR WALL DEMISING WALL 5th FLR≤4'-0"2-2x6 2-2x6 2-2x8 ≤5'-0"2-2x6 2-2x6 ≤8'-0"2-2x8 ≤4'-0"2-2x6 2-2x6 2-2x8 3-2x6 3-2x8 2-2x8 ≤5'-0" ≤8'-0" 737 BISHOP STREET, SUITE 1860 HONOLULU, HI 96813 808-352-5299 OWNER: 523 EAST THIRD AVENUE SPOKANE, WA 99202 P 509.323.9292 F 509.747.7115 HOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 99216OVERALL FLOOR 2 FRAMING PLAN & 2ND FLOOR WALLS S102 FSC PROJECT NO. 21012 PERMIT SET 5/31/2024 GL8 Mirabeau Point, LLC 10909 E. Pierce Lane Spokane, WA 99206 (509) 919-0901 STRUCTURAL COLUMN SCHEDULE MARK COL SIZE REMARKS C444 HSS4x4x1/4 C554 HSS5x5x1/4 C556 HSS5x5x3/8 C558 HSS5x5x1/2 C664 HSS6x6x1/4 C666 HSS6x6x3/8 C756 HSS7X5X3/8 C758 HSS7x5x1/2 C8810 HSS8X8X5/8 W12x35 W12x35 NORTHSCALE:3/32" = 1'-0" OVERALL FLOOR 2 FRAMING PLAN & 2ND FLOOR WALLS Revision Schedule Number Description Date 1 A A B C D E F G H J K L M N P 1.1 22.1 3 3.1 4 5 6 6 6.1 7 7 8 8 8.1 9 9 C.1 L.1 Q 10 10 249'-11"133'-6"55'-11 3/8"19'-0 7/8"19'-0 3/4"19'-1"19'-0 7/8"19'-0 3/4"14'-11"19'-1 1/2"10'-9"14'-11 1/4"19'-1 1/2"19'-9 1/8"25'-8 7/8"13'-4 7/8"5'-9 7/8"9'-3"15'-0 5/8"3'-11 1/4"15'-2 3/4"8'-8 7/8"6'-1 1/4"4'-7 3/8"19'-7 1/4"6'-0"65'-1 1/2" 30'-6 5/8"5'-10 1/4"28'-8 5/8"27'-9 7/8"4'-2 5/8"4'-3 1/8"WS224 @ 3RD FLOOR WS24 @ 4TH & 5TH FLOOR WS26 TYP @ CORRIDOR WALLS WS26 WS26 TYP @ EXT WALLS WS26 WS226 TYP @ 3RD FLOOR DEMISING WALLS, WS26 TYP @ 4TH & 5TH FLOOR DEMISING WALLS WS26 WS26 5 S130 P1-6 P1-6P1-4 P1-64.8K T10.2K C4.8K T10.2K CP1-6 P1-6P1-4P1-4 P1-6 P1-6P2-426.6K T28.7K C26.6K T28.7K CP1-4P1-47.5K T12.7K C6.8K T12.5K C7.5K T12.7K C6.8K T12.5K CP2-425.8K T28.2K C25.8K T28.2K CP1-6 7.0K T12.6K C7.0K T12.6K CP1-4P1-3P1-6 9.4K T16.3K C9.4K T16.3K CP1-6 P1-6P1-32.5K T14.4K C2.5K T14.4K CP1-4 7.5K T13.9K C7.5K T13.9K CP1-6P1-4 7.5K T13.9K C7.5K T13.9K CP1-4 P1-6P1-4P1-47.5K T13.9K C7.5K T13.9K CP1-4 0.3K T11.2K C0.3K T11.2K CP1-47.5K T13.9K C7.5K T13.9K CP1-4 0.3K T11.2K C0.3K T11.2K CP1-4 P1-6P1-4P1-4P1-66.1K T9.9K C6.1K T9.9K CP1-4P1-4P1-4 5.3K T9.6K C5.3K T9.6K CP1-4 5.3K T9.6K C5.3K T9.6K CP1-6 P1-45.3K T9.6K C5.3K T9.6K CP1-45.3K T9.6K C5.3K T9.6K CP1-6P1-4P1-4P1-6P1-4P1-6P1-6P1-4 P1-4 P1-44.1K T7.2K C4.1K T7.2K C5.9K T7.6K C5.9K T7.6K C7.0K T9.4K C7.0K T9.4K C7.1K T9.4K C7.1K T9.4K C7.4K T9.5K C7.4K T9.5K CP1-4 7.9K T10.5K C7.9K T10.5K C4.8K T10.2K C4.8K T10.2K C5.7K T7.5K C5.7K T7.5K C5.0K T7.2K C5.0K T7.2K C0.6K T11.2K C0.6K T11.2K C4.0K T11.3K C4.0K T11.3K C1.4K T7.6K C1.4K T7.6K C2.2K T5.4K C1.0K T5.0K C1.0K T5.0K C2.9K T5.2K C2.9K T5.2K C3.3K T5.6K C3.3K T5.6K C5.7K T8.8K C5.7K T8.8K C5.7K T8.8K C5.7K T8.8K C5.7K T8.8K C5.7K T8.8K C5.7K T8.8K C5.7K T8.8K C5.7K T8.8K C5.7K T8.8K C6.0K T8.9K C6.0K T8.9K C7.9K T9.3K C7.9K T9.3K C5.4K T6.8K C5.4K T6.8K C6.6K T8.8K C6.6K T8.8K C5.4K T6.8K C5.4K T6.8K C3.8K T5.4K C3.8K T5.4K C2.6K T5.1K C2.6K T5.1K CSTRUCTURAL WALL SCHEDULE, UNO NOTES: 1. ALL EXTERIOR WALLS TO BE FRAMED WITH FRT STUDS, PLATES, HEADERS, AND SHEATHING. 2. SEE TYPICAL DETAIL FOR KING AND JACK STUD REQUIREMENTS. 3. SEE SHEARWALL SCHEDULE FOR ADDITIONAL REQUIREMENTS. 2x4 STUDS @ 16" OCWS24 2x6 STUDS @ 16" OC 2x8 STUDS @ 16" OC 2-2x4 STUDS @ 16" OC 2-2x6 STUDS @ 16" OC 3-2x6 STUDS @ 16" OC WS26 WS28 WS224 WS226 WS326 MIN HEADER SCHEDULE, UNO OPENING WIDTH 1st FLR -4th FLREXTERIOR WALL CORRIDOR WALL DEMISING WALL 5th FLR≤4'-0"2-2x6 2-2x6 2-2x8 ≤5'-0"2-2x6 2-2x6 ≤8'-0"2-2x8 ≤4'-0"2-2x6 2-2x6 2-2x8 3-2x6 3-2x8 2-2x8 ≤5'-0" ≤8'-0" 1. SEE S002 FOR CONTINUOUS TIE DOWN SYSTEM NOTES. 2. ALL 1ST FLOOR LEVEL EXTERIOR WALLS TO BE SHEATHED WITH 5/8" FRT SHEATHING, INCLUDING DOUBLE SIDED SHEAR WALLS. 3. ALL 2ND FLOOR LEVEL AND ABOVE EXTERIOR SHEAR WALLS TO BE SHEATHED WITH 5/8" FRT SHEATHING, SECTIONS OF EXTERIOR WALLS NOT DESIGNATED AS SHEAR WALLS MAY BE SHEATHED WITH DENSGLASS SHEATHING MEETING THE FIRE ASSEMBLY REQUIREMENTS. 4. ALIGN STUDS ABOVE WITH STUDS BELOW AT ALL WALLS BEARING ON WALLS THAT DON'T HAVE INTERVENING RIMBOARD (EXTERIOR WALLS AND SHAFT WALLS). OVERALL PLAN NOTES 737 BISHOP STREET, SUITE 1860 HONOLULU, HI 96813 808-352-5299 OWNER: 523 EAST THIRD AVENUE SPOKANE, WA 99202 P 509.323.9292 F 509.747.7115 HOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 99216OVERALL FLOORS 3 FRAMING PLANS & 3RD FLOOR WALLS S103 FSC PROJECT NO. 21012 PERMIT SET 5/31/2024 GL8 Mirabeau Point, LLC 10909 E. Pierce Lane Spokane, WA 99206 (509) 919-0901 NORTHSCALE:3/32" = 1'-0" OVERALL FLOOR 3 FRAMING PLAN & 3RD FLOOR WALLS Revision Schedule Number Description Date STRUCTURAL WALL SCHEDULE, UNO NOTES: 1. ALL EXTERIOR WALLS TO BE FRAMED WITH FRT STUDS, PLATES, HEADERS, AND SHEATHING. 2. SEE TYPICAL DETAIL FOR KING AND JACK STUD REQUIREMENTS. 3. SEE SHEARWALL SCHEDULE FOR ADDITIONAL REQUIREMENTS. 2x4 STUDS @ 16" OCWS24 2x6 STUDS @ 16" OC 2x8 STUDS @ 16" OC 2-2x4 STUDS @ 16" OC 2-2x6 STUDS @ 16" OC 3-2x6 STUDS @ 16" OC WS26 WS28 WS224 WS226 WS326 MIN HEADER SCHEDULE, UNO OPENING WIDTH 1st FLR -4th FLREXTERIOR WALL CORRIDOR WALL DEMISING WALL 5th FLR≤4'-0"2-2x6 2-2x6 2-2x8 ≤5'-0"2-2x6 2-2x6 ≤8'-0"2-2x8 ≤4'-0"2-2x6 2-2x6 2-2x8 3-2x6 3-2x8 2-2x8 ≤5'-0" ≤8'-0" 1. SEE S002 FOR CONTINUOUS TIE DOWN SYSTEM NOTES. 2. ALL 1ST FLOOR LEVEL EXTERIOR WALLS TO BE SHEATHED WITH 5/8" FRT SHEATHING, INCLUDING DOUBLE SIDED SHEAR WALLS. 3. ALL 2ND FLOOR LEVEL AND ABOVE EXTERIOR SHEAR WALLS TO BE SHEATHED WITH 5/8" FRT SHEATHING, SECTIONS OF EXTERIOR WALLS NOT DESIGNATED AS SHEAR WALLS MAY BE SHEATHED WITH DENSGLASS SHEATHING MEETING THE FIRE ASSEMBLY REQUIREMENTS. 4. ALIGN STUDS ABOVE WITH STUDS BELOW AT ALL WALLS BEARING ON WALLS THAT DON'T HAVE INTERVENING RIMBOARD (EXTERIOR WALLS AND SHAFT WALLS). OVERALL PLAN NOTES 1 A A B C D E F G H J K L M N P 1.1 22.1 3 3.1 4 5 6 6 6.1 7 7 8 8 8.1 9 9 C.1 L.1 Q 10 10 11 P1-6 P1-6P1-6 P1-61.4K T5.6K C1.4K T5.6K CP1-6 P1-6P1-6P1-6 P1-6 P1-6P2-614.3K T15.7K C14.3K T15.7K CP1-4P1-44.0K T7.4K C3.5K T7.3K C4.0K T7.4K C3.5K T7.3K CP2-613.9K T15.4K C13.9K T15.4K CP1-6 3.7K T7.4K C3.7K T7.4K CP1-4P1-3P1-6 4.6K T9.2K C4.6K T9.2K CP1-6 P1-6P1-40.5K T8.2K C0.5K T8.2K CP1-4 4.7K T8.8K C4.7K T8.8K CP1-6P1-4 4.7K T8.8K C4.7K T8.8K CP1-6 P1-61.3K T3.7K C1.3K T3.7K CP1-6P1-44.7K T8.8K C4.7K T8.8K CP1-6 P1-44.7K T8.8K C4.7K T8.8K CP1-6 P1-6 P1-6 P1-6P1-4 P1-6P1-6P1-4 P1-61.9K T4.4K C1.9K T4.4K CP1-4P1-6P1-4 1.4K T4.2K C1.4K T4.2K CP1-4 1.4K T4.2K C1.4K T4.2K CP1-6 P1-41.4K T4.2K C1.4K T4.2K CP1-41.4K T4.2K C1.4K T4.2K CP1-6P1-6P1-6P1-6P1-61.7K T3.9K C1.7K T3.9K C2.8K T4.1K C2.8K T4.1K C3.4K T5.1K C3.4K T5.1K C3.4K T5.1K C3.4K T5.1K C3.7K T5.2K C3.7K T5.2K CP1-6 4.0K T5.7K C4.0K T5.7K C2.7K T5.6K C2.7K T5.6K C2.8K T4.1K C2.8K T4.1K C2.4K T3.9K C2.4K T3.9K C1.4K T6.2K C1.4K T6.2K C0.7K T2.8K C4.3K T5.3K C4.3K T5.3K C1.8K T2.9K C1.8K T2.9K C3.5K T5.0K C3.5K T5.0K C1.8K T2.9K C1.8K T2.9K C1.4K T2.9K C1.4K T2.9K C1.4K T2.9K C1.4K T2.9K C1.4K T2.9K C1.4K T2.9K C1.4K T2.9K C1.4K T2.9K C1.4K T2.9K C1.4K T2.9K C1.5K T2.9K C1.5K T2.9K C1.7K T2.8K C1.7K T2.8K C0.8K T2.7K C0.8K T2.7K C1.4K T2.9K C1.4K T2.9K C1.0K T2.7K C1.0K T2.7K C737 BISHOP STREET, SUITE 1860 HONOLULU, HI 96813 808-352-5299 OWNER: 523 EAST THIRD AVENUE SPOKANE, WA 99202 P 509.323.9292 F 509.747.7115 HOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 99216OVERALL 4TH FLOOR FRAMING PLANS & 4TH FLOOR WALLS S104 FSC PROJECT NO. 21012 PERMIT SET 5/31/2024 GL8 Mirabeau Point, LLC 10909 E. Pierce Lane Spokane, WA 99206 (509) 919-0901 NORTHSCALE:3/32" = 1'-0" OVERALL FLOOR 4 FRAMING PLAN & 4TH FLOOR WALLS Revision Schedule Number Description Date STRUCTURAL WALL SCHEDULE, UNO NOTES: 1. ALL EXTERIOR WALLS TO BE FRAMED WITH FRT STUDS, PLATES, HEADERS, AND SHEATHING. 2. SEE TYPICAL DETAIL FOR KING AND JACK STUD REQUIREMENTS. 3. SEE SHEARWALL SCHEDULE FOR ADDITIONAL REQUIREMENTS. 2x4 STUDS @ 16" OCWS24 2x6 STUDS @ 16" OC 2x8 STUDS @ 16" OC 2-2x4 STUDS @ 16" OC 2-2x6 STUDS @ 16" OC 3-2x6 STUDS @ 16" OC WS26 WS28 WS224 WS226 WS326 MIN HEADER SCHEDULE, UNO OPENING WIDTH 1st FLR -4th FLREXTERIOR WALL CORRIDOR WALL DEMISING WALL 5th FLR≤4'-0"2-2x6 2-2x6 2-2x8 ≤5'-0"2-2x6 2-2x6 ≤8'-0"2-2x8 ≤4'-0"2-2x6 2-2x6 2-2x8 3-2x6 3-2x8 2-2x8 ≤5'-0" ≤8'-0" 1. SEE S002 FOR CONTINUOUS TIE DOWN SYSTEM NOTES. 2. ALL 1ST FLOOR LEVEL EXTERIOR WALLS TO BE SHEATHED WITH 5/8" FRT SHEATHING, INCLUDING DOUBLE SIDED SHEAR WALLS. 3. ALL 2ND FLOOR LEVEL AND ABOVE EXTERIOR SHEAR WALLS TO BE SHEATHED WITH 5/8" FRT SHEATHING, SECTIONS OF EXTERIOR WALLS NOT DESIGNATED AS SHEAR WALLS MAY BE SHEATHED WITH DENSGLASS SHEATHING MEETING THE FIRE ASSEMBLY REQUIREMENTS. 4. ALIGN STUDS ABOVE WITH STUDS BELOW AT ALL WALLS BEARING ON WALLS THAT DON'T HAVE INTERVENING RIMBOARD (EXTERIOR WALLS AND SHAFT WALLS). OVERALL PLAN NOTES 1 A A B C D E F G H J K L M N P 1.1 22.1 3 3.1 4 5 6 6 6.1 7 7 8 8 8.1 9 9 C.1 L.1 Q 10 10 11 P1-6 P1-6P1-6 P1-61.0K T2.8K C1.0K T2.8K CP1-6 P1-6P1-6P1-6 P1-6 P1-6P1-45.3K T6.1K C5.3K T6.1K CP1-6P1-61.6K T3.2K C1.3K T3.2K C1.6K T3.2K C1.3K T3.2K CP1-45.1K T5.9K C5.1K T5.9K CP1-6 1.5K T3.2K C1.5K T3.2K CP1-6P1-6P1-6 1.1K T3.6K C1.1K T3.6K CP1-6 P1-6P1-6 P1-4 2.9K T4.8K C2.9K T4.8K CP1-6P1-4 2.9K T4.8K C2.9K T4.8K CP1-6 P1-6P1-6P1-42.9K T4.8K C2.9K T4.8K CP1-6 P1-42.9K T4.8K C2.9K T4.8K CP1-6 P1-6 P1-6 P1-6P1-6 P1-6P1-6P1-6 P1-6P1-6P1-6WS226 WS226 WS226 (GRID D TO GRID J) WS226 WS226 3-2x8 3-2x8 3-2x83-2x8 0.8K T1.6K C0.8K T1.6K C0.9K T2.0K C0.9K T2.0K C0.9K T2.0K C1.0K T2.0K C1.0K T2.0K CP1-6 1.3K T2.2K C1.3K T2.2K C0.7K T1.6K C0.7K T1.6K C0.6K T1.5K C0.6K T1.5K C1.8K T2.5K C1.8K T2.5K C1.3K T2.3K C1.3K T2.3K C737 BISHOP STREET, SUITE 1860 HONOLULU, HI 96813 808-352-5299 OWNER: 523 EAST THIRD AVENUE SPOKANE, WA 99202 P 509.323.9292 F 509.747.7115 HOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 99216OVERALL 5TH FLOOR FRAMING PLANS & 5TH FLOOR WALLS S105 FSC PROJECT NO. 21012 PERMIT SET 5/31/2024 GL8 Mirabeau Point, LLC 10909 E. Pierce Lane Spokane, WA 99206 (509) 919-0901 NORTHSCALE:3/32" = 1'-0" OVERALL FLOOR 5 FRAMING PLAN & 5TH FLOOR WALLS Revision Schedule Number Description Date 1 A A B C D E F G H J K M N P 1.1 2.1 3 4 5 6 6 7 7 8 8 8.1 9 9 Q 10 10 249'-11"4'-3 1/8"133'-6"65'-1 1/2" 30'-6 5/8"5'-10 1/4"28'-8 5/8" 75'-0 1/4"19'-0 3/4"19'-1"19'-0 7/8"19'-0 3/4"14'-11"29'-10 1/2"14'-11 1/4"19'-1 1/2"19'-9 1/8"25'-8 7/8"13'-4 7/8"15'-0 7/8"15'-0 5/8"3'-11 1/4"23'-11 5/8"6'-1 1/4"4'-7 3/8"19'-7 1/4"6'-0"60'-3 1/2"23'-11 5/8"6'-1 1/4"24'-2 5/8"6'-0"TYP 5/8" APA RATED SHTGTYP 5/8" APA RATED SHTGT.O.P. 65'-10"54'-3 1/2"T.O.P. 65'-10"T.O.P. 63'-10" T.O.P. 63'-10" T.O.P. 63'-10" T.O.P. 63'-10" T.O.P. 65'-10" T.O.P. 69'-10" T.O.P. 65'-10" T.O.P. 63'-10" T.O.P. 63'-10" T.O.P. 65'-10" T.O.P. 63'-10" T.O.P. 69'-10"T.O.P. 63'-10" T.O.P. 65'-10" T.O.P. 63'-10" T.O.P. 65'-10" ERV-01 6,500# CU-02 1,500# CU-03 1,500# STRUCTURAL WALL SCHEDULE, UNO NOTES: 1. ALL EXTERIOR WALLS TO BE FRAMED WITH FRT STUDS, PLATES, HEADERS, AND SHEATHING. 2. SEE TYPICAL DETAIL FOR KING AND JACK STUD REQUIREMENTS. 3. SEE SHEARWALL SCHEDULE FOR ADDITIONAL REQUIREMENTS. 2x4 STUDS @ 16" OCWS24 2x6 STUDS @ 16" OC 2x8 STUDS @ 16" OC 2-2x4 STUDS @ 16" OC 2-2x6 STUDS @ 16" OC 3-2x6 STUDS @ 16" OC WS26 WS28 WS224 WS226 WS326 MIN HEADER SCHEDULE, UNO OPENING WIDTH 1st FLR -4th FLREXTERIOR WALL CORRIDOR WALL DEMISING WALL 5th FLR≤4'-0"2-2x6 2-2x6 2-2x8 ≤5'-0"2-2x6 2-2x6 ≤8'-0"2-2x8 ≤4'-0"2-2x6 2-2x6 2-2x8 3-2x6 3-2x8 2-2x8 ≤5'-0" ≤8'-0" 1. SEE S002 FOR CONTINUOUS TIE DOWN SYSTEM NOTES. 2. ALL 1ST FLOOR LEVEL EXTERIOR WALLS TO BE SHEATHED WITH 5/8" FRT SHEATHING, INCLUDING DOUBLE SIDED SHEAR WALLS. 3. ALL 2ND FLOOR LEVEL AND ABOVE EXTERIOR SHEAR WALLS TO BE SHEATHED WITH 5/8" FRT SHEATHING, SECTIONS OF EXTERIOR WALLS NOT DESIGNATED AS SHEAR WALLS MAY BE SHEATHED WITH DENSGLASS SHEATHING MEETING THE FIRE ASSEMBLY REQUIREMENTS. 4. ALIGN STUDS ABOVE WITH STUDS BELOW AT ALL WALLS BEARING ON WALLS THAT DON'T HAVE INTERVENING RIMBOARD (EXTERIOR WALLS AND SHAFT WALLS). OVERALL PLAN NOTES 737 BISHOP STREET, SUITE 1860 HONOLULU, HI 96813 808-352-5299 OWNER: 523 EAST THIRD AVENUE SPOKANE, WA 99202 P 509.323.9292 F 509.747.7115 HOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 99216OVERALL ROOF FRAMING PLAN & PARAPET WALLS S106 FSC PROJECT NO. 21012 PERMIT SET 5/31/2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce Lane Spokane, WA 99206 (509) 919-0901 NORTHSCALE:3/32" = 1'-0" OVERALL ROOF FRAMING PLAN & PARAPET WALLS Revision Schedule Number Description Date -SS- -SS--SS--SS-1 1 A A B C D E 2 2.1 3 3.1 4 5 6 6 6.1 7 7 8 8 8.1 9 9 C.1 65'-1 1/2" 30'-6 5/8"5'-10 1/4"28'-8 5/8"131'-9 1/8"30'-0"13'-4 7/8"5'-9 7/8"9'-3"15'-0 5/8"3'-11 1/4"15'-2 3/4"8'-8 7/8"6'-1 1/4"4'-7 3/8"19'-7 1/4"W12x35W12x35W12x35W12x35W12x35W12x35C556C554C554C558C556C556C558C558C556C554C558C756C758C554C556C554C556C558C554C556C556C556C758C556C556C556C554C758C554F40 F30 F30 F50 F40 F40 F50F50F40F30 F50 F50 F50F40 F40 F40 F80 F50 F50 F30 F40 F40 F40 F60 F40F50 F40 F30 F50 F40 F60F60F60F60F60 F602x8 @ 16" OCPOOL BY OTHERS7"10'-5 5/8"8'-6"10'-5 3/8"5 1/4"4'-2" 11 7/8" 12'-10 3/8"11'-1"11'-1"11'-1"12'-10 3/8" 11 7/8"11'-0 5/8"8'-6"8'-3 1/4"C5545 1/2"4 5/8"F50 F50 6'-0 1/8"5'-9"1'-11 3/4"T.O.PIER 5'-10" TYPC554C554 T.O.F. -5'-0" T.O.F. -3'-6"C5542 3/4"9"3'-11 1/4"10'-0 1/2"F.O.C.F.O.C.F.O.C. F.O.C. F.O.C.F.O.C.F.O.C.C8810C554F508'-11"1'-9 3/4"7'-5 1/4"9'-2 3/4"10'-0 1/2"2'-1 7/8"3'-11 1/8" 7'-1" 4'-4" 6'-4" 11'-2 3/4"5 1/4"2'-6" 5 1/4" T.O.P. -3'-6" 1 S301 __________ SW8CF24 CF24 SW8 1 S301 __________ TS18TS18 TS18 CF24SW8 1 S301 __________ TS18 TS18 TS18 10 S301 __________ T.O.F. -2'-0"TS18TS188 S301 __________ TYP (UNO) @ THICKENED SLAB 8 S301 __________CF24SW8 CF24SW8 1 S301 __________CF18SW10 2 S301 __________ 1 S301 __________CF24SW8 SW14 2 S301 __________CF18SW10 TS18F30C756T.O.F. -2'-0" TYP @ PERIM, UNO T.O.F. -2'-0" TYP @ PERIM, UNO __________ S004 13 TYP @ INTR COL, UNO T.O.F. -1'-0" TYP @ INTR COL, UNO 3 S301 __________ TYP @ PERIM COLS, UNO 3 S301 __________ TYP @ PERIM COLS, UNO C554C554C554C554C554C5548'-11 3/4"9'-3 1/2"1'-0"(-1'-0") HSS4x4x1/4 16 S301 __________ T.O.F. -2'-8" 18 S301 __________ 1. SEE S0-SERIES FOR GENERAL STRUCTURAL NOTES, ABBREVIATIONS, LEGEND & TYPICAL DETAILS. 2. COORDINATE & VERIFY ALL DIMENSIONS WITH ARCHL DRAWINGS. 3. ALL DIMENSION LINES ARE CENTERLINE OF COL, FACE OF STUD, OR FACE OF CONCRETE, UNO. 4. LOCATE FOOTINGS ON CENTERLINE OF WALLS, COLUMNS, ETC UNO. 5. SEE GEOTECHNICAL REPORT FOR RECOMMENDED SUBGRADE PREPARATION BELOW FOOTINGS AND SLABS ON GRADE. 6. PIPES MAY PASS THROUGH STRUCTURAL CONCRETE IN SLEEVES BUT SHALL NOT BE EMBEDDED THEREIN - SEE TYPICAL DETAIL. 7. PROVIDE 3/4" CHAMFER AT ALL EXPOSED CONCRETE CORNERS. 8. SEE ARCHL DRAWINGS FOR EXTERIOR WALKS, CURBS, ETC. 9. REFER TO ALL ARCHITECTURAL, ELECTRICAL & MECHANICAL PLANS FOR PROPER COORDINATION WITH ALL OTHER TRADES. FLOOR/FOUNDATION PLAN NOTES 737 BISHOP STREET, SUITE 1860 HONOLULU, HI 96813 808-352-5299 OWNER: 523 EAST THIRD AVENUE SPOKANE, WA 99202 P 509.323.9292 F 509.747.7115 HOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 99216FLOOR/FOUNDATION PLAN - WEST WING S121 FSC PROJECT NO. 21012 PERMIT SET 5/31/2024 GL8 Mirabeau Point, LLC 10909 E. Pierce Lane Spokane, WA 99206 (509) 919-0901 NORTHSCALE:1/8" = 1'-0" FLOOR / FOUNDATION PLAN - WEST WING STRUCTURAL FOOTING SCHEDULE MARK FOOTING SIZE REINFORCEMENT CF18 CONT 1'-6" x 12" DP 2-#4 CONT CF24 CONT 2'-0" x 12" DP 3-#4 CONT F30 3'-0" SQ x12" DP 4-#4 EW BOT F40 4'-0" SQ x12" DP 5-#4 EW BOT F50 5'-0" SQ x15" DP 6-#5 EW BOT F60 6'-0" SQ x16" DP 7-#5 EW BOT F80 8'-0" SQ x 18" DP 9-#6 EW BOT STRUCTURAL COLUMN SCHEDULE MARK COL SIZE REMARKS C444 HSS4x4x1/4 C554 HSS5x5x1/4 C556 HSS5x5x3/8 C558 HSS5x5x1/2 C664 HSS6x6x1/4 C666 HSS6x6x3/8 C756 HSS7X5X3/8 C758 HSS7x5x1/2 C8810 HSS8X8X5/8 W12x35 W12x35 FOUNDATION STEM WALLS MARK STEM WALL REF. DETAIL, UNO SW8 8" CONC SW10 10" CONC SW12 12" CONC SW14 14" CONC Revision Schedule Number Description Date -SS- -SS--SS--SS-E E F F G G H H J J K K L M M N N P P 4 5 6 6 7 7 8 8 9 9 C.1 L.1 L.1 Q Q 10 1060'-3 1/2"23'-11 5/8"6'-1 1/4"24'-2 5/8"6'-0"C556C556C758C554C758C554C558C556C556C756C556C556C556C556C756C556C558C558C556C556C554C758C554C666C666C664C664C664C664C666C666C556C556F40 F40 F60 F50 F60 F50 F60 F50 F40 F50 F40 F40F40 F40 F50 F40 F50F50 F40 F30 F50 F40 F50 F50 F40 F40 F40 F40 F50 F50 F40 F40 TYP 4" CONC SLAB ON GRADE W/ FIBER REINFORCEMENT T.O. SLAB ELEV = 0'-0" TYP @ EXTR, UNO T.O.F. -1'-0" TYP @ INTR COL, UNO T.O.F. -2'-0" TYP @ PERIM, UNO 7 1/2"6 3/8"C558C554C554T.O.F. -5'-0" T.O.F. -3'-6"C5546'-3" 6'-7"F.O.C.19'-0 7/8"19'-0 3/4"19'-1"19'-0 7/8"19'-0 3/4"14'-11"19'-1 1/2"10'-9"14'-11 1/4"19'-1 1/2"19'-9 1/8" 193'-11 5/8" 4'-2 5/8"5 1/4"2'-0"5 1/4"C558C558C558C558T.O.F. -2'-0" F40 F40 5'-0 5/8"7'-5 1/4"9'-2 3/4"C444C4448'-1"5 3/8"5 7/8"3"1'-0"5 7/8"5 1/4"F30 F30 2'-11 7/8" 2'-1 7/8"3'-11 1/8"6'-4"4'-7"4'-0"3'-3"7 1/2"5 7/8"5 3/8"4'-0"2'-0"4 3/4"5 1/4"11 3/8"3'-6 3/8"3'-6 1/2"C558T.O.P. -3'-6" F30 F30C444C4448'-1" 1'-6 1/2" 11'-0"TS18TS24TS24 TS18TS18TS24TS24TS24TS18TS18TS24 TS24CF24 8 S301 __________ SW8 SW8 1 S301 __________ CF24 SW8 CF24 1 S301 __________CF24SW8CF24SW8 1 S301 __________ 8 S301 __________ TYP (UNO) @ THICKENED SLAB CF24 SW8 1 S301 __________ 3 S301 __________TYP @ PERIM COLS, UNO __________ S004 13TYP @ INTR COL, UNO CF18 SW8 10 S301 __________ 10 S301 __________ 1 S301 __________ SW8CF24 CF24 SW8 1 S301 __________ TS18 TS18F30 11'-0" 5"TYP @ PERIM, UNO T.O.F. -2'-0" 3 S301 __________ TYP @ PERIM COLS, UNOC554C554C554C554C554C5548'-11 3/4"9'-3 1/2"1'-0"(-1'-0") HSS4x4x1/4 16 S301 __________ 18 S301 __________ 1. SEE S0-SERIES FOR GENERAL STRUCTURAL NOTES, ABBREVIATIONS, LEGEND & TYPICAL DETAILS. 2. COORDINATE & VERIFY ALL DIMENSIONS WITH ARCHL DRAWINGS. 3. ALL DIMENSION LINES ARE CENTERLINE OF COL, FACE OF STUD, OR FACE OF CONCRETE, UNO. 4. LOCATE FOOTINGS ON CENTERLINE OF WALLS, COLUMNS, ETC UNO. 5. SEE GEOTECHNICAL REPORT FOR RECOMMENDED SUBGRADE PREPARATION BELOW FOOTINGS AND SLABS ON GRADE. 6. PIPES MAY PASS THROUGH STRUCTURAL CONCRETE IN SLEEVES BUT SHALL NOT BE EMBEDDED THEREIN - SEE TYPICAL DETAIL. 7. PROVIDE 3/4" CHAMFER AT ALL EXPOSED CONCRETE CORNERS. 8. SEE ARCHL DRAWINGS FOR EXTERIOR WALKS, CURBS, ETC. 9. REFER TO ALL ARCHITECTURAL, ELECTRICAL & MECHANICAL PLANS FOR PROPER COORDINATION WITH ALL OTHER TRADES. FLOOR/FOUNDATION PLAN NOTES 737 BISHOP STREET, SUITE 1860 HONOLULU, HI 96813 808-352-5299 OWNER: 523 EAST THIRD AVENUE SPOKANE, WA 99202 P 509.323.9292 F 509.747.7115 HOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 99216FLOOR/FOUNDATION PLAN - EAST WING S122 FSC PROJECT NO. 21012 PERMIT SET 5/31/2024 GL8 Mirabeau Point, LLC 10909 E. Pierce Lane Spokane, WA 99206 (509) 919-0901 NORTHSCALE:1/8" = 1'-0" FLOOR / FOUNDATION PLAN - EAST WING STRUCTURAL FOOTING SCHEDULE MARK FOOTING SIZE REINFORCEMENT CF18 CONT 1'-6" x 12" DP 2-#4 CONT CF24 CONT 2'-0" x 12" DP 3-#4 CONT F30 3'-0" SQ x12" DP 4-#4 EW BOT F40 4'-0" SQ x12" DP 5-#4 EW BOT F50 5'-0" SQ x15" DP 6-#5 EW BOT F60 6'-0" SQ x16" DP 7-#5 EW BOT F80 8'-0" SQ x 18" DP 9-#6 EW BOT STRUCTURAL COLUMN SCHEDULE MARK COL SIZE REMARKS C444 HSS4x4x1/4 C554 HSS5x5x1/4 C556 HSS5x5x3/8 C558 HSS5x5x1/2 C664 HSS6x6x1/4 C666 HSS6x6x3/8 C756 HSS7X5X3/8 C758 HSS7x5x1/2 C8810 HSS8X8X5/8 W12x35 W12x35 FOUNDATION STEM WALLS MARK STEM WALL REF. DETAIL, UNO SW8 8" CONC SW10 10" CONC SW12 12" CONC SW14 14" CONC Revision Schedule Number Description Date F G H 9 9 10 10 11 19'-1"19'-0 7/8"28'-0"C556C756C556C556C556C556C756C556C554C554F40 F50 F40 F40F40 F40 F50 F40 F50F50 7'-7 5/8" 6'-4 3/8" 6'-4 1/4" 7'-11 3/4" 7 1/2" 6"6" 6 3/8"6"6'-9" 7'-1"5'-0 5/8"F50F50C554C55411 3/8"3'-6 3/8"3'-6 1/2"SW8 1 S301 __________ F G H 9 9 10 10 11 11 19'-1"19'-0 7/8"W16x26W16x26W18x50 W10x12W16x40W16x40W10x12W16x31 SLOPE1/2 : 121½"x20GA TYPE 'B' STL ROOF DECK GALV 2'-11"6'-4 3/8" 6'-4 3/8" 6'-4 3/8" 6'-4 1/4" 6'-4 1/4" 6'-4 1/4" 2'-11 1/8"W14x26W14x26W14x26W14x26W14x26W14x26W14x26W18x35 (CONT) (16'-10 5/8")FJ6FJ6FJ6FJ611 S402 __________ 13 S402 __________7'-0"7'-0"7'-0"7'-0"15 S402 __________ 15 S402 __________W14x26W14x26W14x26W14x26W14x26W14x26W14x261. SEE S0-SERIES FOR GENERAL STRUCTURAL NOTES, ABBREVIATIONS, LEGEND & TYPICAL DETAILS. 2. COORDINATE & VERIFY ALL DIMENSIONS WITH ARCHL DRAWINGS. 3. ALL DIMENSION LINES ARE CENTERLINE OF COL, FACE OF STUD, OR FACE OF CONCRETE, UNO. 4. LOCATE FOOTINGS ON CENTERLINE OF WALLS, COLUMNS, ETC UNO. 5. SEE GEOTECHNICAL REPORT FOR RECOMMENDED SUBGRADE PREPARATION BELOW FOOTINGS AND SLABS ON GRADE. 6. PIPES MAY PASS THROUGH STRUCTURAL CONCRETE IN SLEEVES BUT SHALL NOT BE EMBEDDED THEREIN - SEE TYPICAL DETAIL. 7. PROVIDE 3/4" CHAMFER AT ALL EXPOSED CONCRETE CORNERS. 8. SEE ARCHL DRAWINGS FOR EXTERIOR WALKS, CURBS, ETC. 9. REFER TO ALL ARCHITECTURAL, ELECTRICAL & MECHANICAL PLANS FOR PROPER COORDINATION WITH ALL OTHER TRADES. FLOOR/FOUNDATION PLAN NOTES 737 BISHOP STREET, SUITE 1860 HONOLULU, HI 96813 808-352-5299 OWNER: 523 EAST THIRD AVENUE SPOKANE, WA 99202 P 509.323.9292 F 509.747.7115 HOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 99216PORTE COCHERE FOUNDATION & ROOF FRAMING PLANS S123 FSC PROJECT NO. 21012 PERMIT SET 5/31/2024 GL8 Mirabeau Point, LLC 10909 E. Pierce Lane Spokane, WA 99206 (509) 919-0901 NORTHSCALE:1/8" = 1'-0" PORTE COCHERE FOUNDATION PLAN NORTHSCALE:1/8" = 1'-0" PORTE COCHERE ROOF FRAMING PLAN STRUCTURAL FOOTING SCHEDULE MARK FOOTING SIZE REINFORCEMENT CF18 CONT 1'-6" x 12" DP 2-#4 CONT CF24 CONT 2'-0" x 12" DP 3-#4 CONT F30 3'-0" SQ x12" DP 4-#4 EW BOT F40 4'-0" SQ x12" DP 5-#4 EW BOT F50 5'-0" SQ x15" DP 6-#5 EW BOT F60 6'-0" SQ x16" DP 7-#5 EW BOT F80 8'-0" SQ x 18" DP 9-#6 EW BOT STRUCTURAL COLUMN SCHEDULE MARK COL SIZE REMARKS C444 HSS4x4x1/4 C554 HSS5x5x1/4 C556 HSS5x5x3/8 C558 HSS5x5x1/2 C664 HSS6x6x1/4 C666 HSS6x6x3/8 C756 HSS7X5X3/8 C758 HSS7x5x1/2 C8810 HSS8X8X5/8 W12x35 W12x35 Revision Schedule Number Description Date 1 A A B C D E 1.1 2 2.1 3 3.1 4 5 6 6 6.1 7 7 8 8 8.1 9 9 C.1 65'-1 1/2" 30'-6 5/8"5'-10 1/4"28'-8 5/8"C558FJ1FJ1C558W18X40 W21x68W21x68W21X55W21X55W16x26 W21x68 W24x76 LVL 5 1/4x11 7/8W16x36 W16x31W10x19 W21x68 W21x68 W21x68 W16x26C558C558C558 W14x26FJ31½"x20GA TYPE 'B'STL ROOF DECK GALVW30x108W12x16W24x55W24x55W12x26 W12x35 W12x35 W18X40 W30x90W21x44 W12x22 W12x35 W12x35 W24x84 W30x90W12x16W24x55W12x16W16x31W16x31 W14x22W16x31W24x76W18X40 127'-6"25'-8 7/8"13'-4 7/8"5'-9 7/8"9'-3"15'-0 5/8"3'-11 1/4"15'-2 3/4"8'-8 7/8"6'-1 1/4"4'-7 3/8"19'-7 1/4"4'-3 1/8"27'-9 7/8"75'-0 1/4" 55'-11 3/8"19'-0 7/8" FJ4 FJ4 FJ4 FJ4 FJ4 FJ4 FJ4 FJ6 FJ4 FJ5 FJ6 FJ6 FJ6 FJ6FJ6FJ6 FJ6 FJ1 FJ5FJ6FJ6(13'-6 7/8")W16x316 S401 __________ 11'-0" 3'-10"6'-5 3/4"11'-0" W18x35 W18x35C554C554C554C554C554C554 LVL 5 1/4x11 7/8 HSS4x4x1/4 (16'-0") (9'-0") 3 S401 __________ 6 S401 __________ 6 S401 __________ 4 S401 __________ 3 S401 __________ 1 S401 __________3 S401 __________ SHADED AREA INDICATES 2x6 FLAT BLOCKING REQ'D W/ E.N. AT ALL PANEL EDGES (16'-0") (9'-0") HSS5x5x1/4 1. SEE S0-SERIES SHEETS FOR GENERAL STRUCTURAL NOTES, ABBREVIATIONS, LEGEND & TYPICAL DETAILS. 2. COORDINATE AND VERIFY ALL DIMENSIONS WITH ARCHITECTURAL DRAWINGS. 3. REFER TO ALL ARCHITECTURAL, ELECTRICAL, & MECHANICAL DRAWINGS FOR PROPER COORDINATION WITH OTHER TRADES. 4. COORDINATE FLOOR JOIST LOCATIONS WITH MECHANICAL & PLUMBING PENETRATIONS. FLOOR FRAMING PLAN NOTESFLOOR JOIST SCHEDULE, UNO 2x8 @ 16" OCFJ1 2-2x8 @ 16" OCFJ2 FJ3 FJ4 11 7/8" RED-I45 @ 19.2" OC 2-LVL1 3/4x7 1/4 @ 16" OC FJ6 FJ5 11 7/8" RED-I45 @ 16" OC 11 7/8" RED-I65 @ 16" OC 737 BISHOP STREET, SUITE 1860 HONOLULU, HI 96813 808-352-5299 OWNER: 523 EAST THIRD AVENUE SPOKANE, WA 99202 P 509.323.9292 F 509.747.7115 HOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 99216FLOOR 2 FRAMING PLAN - WEST WING S124 FSC PROJECT NO. 21012 PERMIT SET 5/31/2024 GL8 Mirabeau Point, LLC 10909 E. Pierce Lane Spokane, WA 99206 (509) 919-0901 NORTHSCALE:1/8" = 1'-0" FLOOR 2 FRAMING PLAN - WEST WING STRUCTURAL COLUMN SCHEDULE MARK COL SIZE REMARKS C444 HSS4x4x1/4 C554 HSS5x5x1/4 C556 HSS5x5x3/8 C558 HSS5x5x1/2 C664 HSS6x6x1/4 C666 HSS6x6x3/8 C756 HSS7X5X3/8 C758 HSS7x5x1/2 C8810 HSS8X8X5/8 W12x35 W12x35 Revision Schedule Number Description Date E F G H J K L M N P 4 5 6 6 7 7 8 8 9 9 C.1 L.1 Q 10 10C558C558C558C558C558C558C558W21x68W21x68W21x68W21x68LVL 5 1/4x11 7/8 W21x68W21x68W21X55W12x16W12x16W18X40 W16x26W16x26W18x50W21x68W21x68W21x68W16x26 W16x31 W12x16 W21X55 W12x16W10x19 W16x26 W16x26 W16x26 W18x35 W10x12W16x40W16x40W10x12W21X55W16x31 W21X55 __________ S130 1 19'-0 7/8"19'-0 3/4"19'-1"19'-0 7/8"19'-0 3/4"14'-11"19'-1 1/2"10'-9"14'-11 1/4"19'-1 1/2"19'-9 1/8" 193'-11 5/8"FJ6FJ5FJ1 FJ6FJ6FJ6FJ6FJ6FJ6FJ6FJ6FJ4FJ4FJ6FJ4FJ5 FJ4FJ4FJ6FJ6FJ6FJ6SEE 2/S123 FOR PORTE COCHERE FRAMING CANOPY BELOW 6 S401 __________ 6 S401 __________6 S401 __________ 5 S130 3 S130 C558W21x68 W14x22C8X11.5 C8X11.5 W8X13C8X11.5 C8X11.5 4 1/2"4 1/2" 11'-0"11'-0" 4 1/2"4 1/2" 11'-0"11'-0" W18x35W18x35W18x35C554C554C554C554C554C554 LVL 5 1/4x11 7/8 HSS4x4x1/4 (16'-0") (9'-0") 3 S401 __________3 S401 __________ 3 S401 __________ 1 S401 __________ 4 S401 __________ 4 S401 __________ __________ S601 A __________ S601 A SHADED AREA INDICATES 2x6 FLAT BLOCKING REQ'D W/ E.N. AT ALL PANEL EDGES (16'-0") (9'-0") HSS5x5x1/4 1. SEE S0-SERIES SHEETS FOR GENERAL STRUCTURAL NOTES, ABBREVIATIONS, LEGEND & TYPICAL DETAILS. 2. COORDINATE AND VERIFY ALL DIMENSIONS WITH ARCHITECTURAL DRAWINGS. 3. REFER TO ALL ARCHITECTURAL, ELECTRICAL, & MECHANICAL DRAWINGS FOR PROPER COORDINATION WITH OTHER TRADES. 4. COORDINATE FLOOR JOIST LOCATIONS WITH MECHANICAL & PLUMBING PENETRATIONS. FLOOR FRAMING PLAN NOTESFLOOR JOIST SCHEDULE, UNO 2x8 @ 16" OCFJ1 2-2x8 @ 16" OCFJ2 FJ3 FJ4 11 7/8" RED-I45 @ 19.2" OC 2-LVL1 3/4x7 1/4 @ 16" OC FJ6 FJ5 11 7/8" RED-I45 @ 16" OC 11 7/8" RED-I65 @ 16" OC 737 BISHOP STREET, SUITE 1860 HONOLULU, HI 96813 808-352-5299 OWNER: 523 EAST THIRD AVENUE SPOKANE, WA 99202 P 509.323.9292 F 509.747.7115 HOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 99216FLOOR 2 FRAMING PLAN - EAST WING S125 FSC PROJECT NO. 21012 PERMIT SET 5/31/2024 GL8 Mirabeau Point, LLC 10909 E. Pierce Lane Spokane, WA 99206 (509) 919-0901 NORTHSCALE:1/8" = 1'-0" FLOOR 2 FRAMING PLAN - EAST WING STRUCTURAL COLUMN SCHEDULE MARK COL SIZE REMARKS C444 HSS4x4x1/4 C554 HSS5x5x1/4 C556 HSS5x5x3/8 C558 HSS5x5x1/2 C664 HSS6x6x1/4 C666 HSS6x6x3/8 C756 HSS7X5X3/8 C758 HSS7x5x1/2 C8810 HSS8X8X5/8 W12x35 W12x35 Revision Schedule Number Description Date 1 A A B C D E 1.1 2 2.1 3 3.1 4 5 6 6 6.1 7 7 8 8 8.1 9 9 C.1 65'-1 1/2" 30'-6 5/8"5'-10 1/4"28'-8 5/8"127'-6"25'-8 7/8"13'-4 7/8"5'-9 7/8"9'-3"15'-0 5/8"3'-11 1/4"15'-2 3/4"8'-8 7/8"6'-1 1/4"4'-7 3/8"19'-7 1/4"4'-3 1/8"75'-0 1/4" 55'-11 3/8"19'-0 7/8"27'-9 7/8"FJ1FJ1FJ3FJ4 FJ4 FJ4 FJ4 FJ4 FJ4 FJ4 FJ6 FJ4 FJ5 FJ6 FJ6 FJ6 FJ6FJ6FJ6 FJ6 FJ1 FJ5FJ6FJ6LVL 5 1/4x11 7/8 LVL 3 1/2x11 7/8 LVL 5 1/4x11 7/8__________ S601 B __________ S601 B W16x36 C554C554C554C554C554C554HSS4x4x1/4 (26'-0") (38'-0") (49'-0") (53'-2") (57'-11) 1 S401 __________ 3 S401 __________ 4 S401 __________ 6 S401 __________ 4 S401 __________ 3 S401 __________ 4 S401 __________ 3 S401 __________ 1 S401 __________ HSS5x5x1/4 (26'-0") (38'-0") (49'-0") (57'-11) 1. SEE S0-SERIES SHEETS FOR GENERAL STRUCTURAL NOTES, ABBREVIATIONS, LEGEND & TYPICAL DETAILS. 2. COORDINATE AND VERIFY ALL DIMENSIONS WITH ARCHITECTURAL DRAWINGS. 3. REFER TO ALL ARCHITECTURAL, ELECTRICAL, & MECHANICAL DRAWINGS FOR PROPER COORDINATION WITH OTHER TRADES. 4. COORDINATE FLOOR JOIST LOCATIONS WITH MECHANICAL & PLUMBING PENETRATIONS. FLOOR FRAMING PLAN NOTESFLOOR JOIST SCHEDULE, UNO 2x8 @ 16" OCFJ1 2-2x8 @ 16" OCFJ2 FJ3 FJ4 11 7/8" RED-I45 @ 19.2" OC 2-LVL1 3/4x7 1/4 @ 16" OC FJ6 FJ5 11 7/8" RED-I45 @ 16" OC 11 7/8" RED-I65 @ 16" OC 737 BISHOP STREET, SUITE 1860 HONOLULU, HI 96813 808-352-5299 OWNER: 523 EAST THIRD AVENUE SPOKANE, WA 99202 P 509.323.9292 F 509.747.7115 HOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 99216FLOORS 3 THRU 5 FRAMING PLANS - WEST WING S126 FSC PROJECT NO. 21012 PERMIT SET 5/31/2024 GL8 Mirabeau Point, LLC 10909 E. Pierce Lane Spokane, WA 99206 (509) 919-0901 NORTHSCALE:1/8" = 1'-0" FLOORS 3 THRU 5 FRAMING PLANS - WEST WING Revision Schedule Number Description Date E F G H J K L M N P 4 5 5 6 6 7 7 8 8 9 9 C.1 L.1 Q 10 10 19'-0 7/8"19'-0 3/4"19'-1"19'-0 7/8"19'-0 3/4"14'-11"19'-1 1/2"10'-9"14'-11 1/4"19'-1 1/2"19'-9 1/8" 193'-11 5/8" 4'-2 5/8"FJ6FJ1 FJ5FJ1 FJ6FJ6FJ6FJ6FJ6FJ6FJ6FJ6FJ4FJ4FJ6FJ4FJ5 FJ4FJ4FJ6FJ6FJ6FJ6LVL 5 1/4x11 7/8 __________ S601 A __________ S601 A __________ S601 C __________ S601 CC554C554C554C554C554C554 HSS4x4x1/4 (26'-0") (38'-0") (49'-0") (53'-2") (57'-11) 3 S401 __________ 4 S401 __________ 4 S401 __________4 S401 __________ 4 S401 __________ 1 S401 __________ 3 S401 __________ 3 S401 __________ HSS5x5x1/4 (26'-0") (38'-0") (49'-0") (57'-11) 1. SEE S0-SERIES SHEETS FOR GENERAL STRUCTURAL NOTES, ABBREVIATIONS, LEGEND & TYPICAL DETAILS. 2. COORDINATE AND VERIFY ALL DIMENSIONS WITH ARCHITECTURAL DRAWINGS. 3. REFER TO ALL ARCHITECTURAL, ELECTRICAL, & MECHANICAL DRAWINGS FOR PROPER COORDINATION WITH OTHER TRADES. 4. COORDINATE FLOOR JOIST LOCATIONS WITH MECHANICAL & PLUMBING PENETRATIONS. FLOOR FRAMING PLAN NOTESFLOOR JOIST SCHEDULE, UNO 2x8 @ 16" OCFJ1 2-2x8 @ 16" OCFJ2 FJ3 FJ4 11 7/8" RED-I45 @ 19.2" OC 2-LVL1 3/4x7 1/4 @ 16" OC FJ6 FJ5 11 7/8" RED-I45 @ 16" OC 11 7/8" RED-I65 @ 16" OC 737 BISHOP STREET, SUITE 1860 HONOLULU, HI 96813 808-352-5299 OWNER: 523 EAST THIRD AVENUE SPOKANE, WA 99202 P 509.323.9292 F 509.747.7115 HOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 99216FLOORS 3 THRU 5 FRAMING PLANS - EAST WING S127 FSC PROJECT NO. 21012 PERMIT SET 5/31/2024 GL8 Mirabeau Point, LLC 10909 E. Pierce Lane Spokane, WA 99206 (509) 919-0901 NORTHSCALE:1/8" = 1'-0" FLOORS 3 THRU 5 FRAMING PLANS - EAST WING Revision Schedule Number Description Date 1 A A B C D E 1.1 2 2.1 3 3.1 4 5 6 6 6.1 7 7 8 8 8.1 9 9 65'-1 1/2" 30'-6 5/8"5'-10 1/4"28'-8 5/8" TYP 5/8" APA RATED SHTG T.O.P. 65'-10" 6 S501 __________ 6 S501 __________ 6 S501 __________ 6 S501 __________ 6 S501 __________ 6 S501 __________ 6 S501 __________ 6 S501 __________127'-6"4'-3 1/8"75'-0 1/4"27'-9 7/8"25'-8 7/8"13'-4 7/8"5'-9 7/8"9'-3"15'-0 5/8"3'-11 1/4"15'-2 3/4"8'-8 7/8"6'-1 1/4"4'-7 3/8"19'-7 1/4"W14x22 RJ2 RJ2 RJ2 RJ2 RJ2 RJ2 RJ2 RJ2 RJ2 RJ2 RJ2RJ2RJ4 RJ2RJ4 RJ2 RJ2 RJ2RJ2RJ1RJ2RJ2RJ2RJ1RJ1RJ6 RJ6 RJ3 RJ2 RJ5 RJ5 RJ5 RJ5 CU-05 150# CU-04 150# 19 S501 __________ 16 S501 __________ 16 S501 __________ 16 S501 __________ SIM 17 S501 __________ HSS8x4x1/4 HSS8x4x1/4 (62'-10") (62'-10") HSS8x4x1/4 (62'-10") W8x18, 2 PLCS (62'-10"), SEE NOTE 6 11 S502 __________ 13 S502 __________ 1. SEE S0-SERIES SHEETS FOR GENERAL STRUCTURAL NOTES, ABBREVIATIONS, LEGEND & TYPICAL DETAILS. 2. COORDINATE AND VERIFY ALL DIMENSIONS WITH ARCHITECTURAL DRAWINGS. 3. REFER TO ALL ARCHITECTURAL, ELECTRICAL, & MECHANICAL DRAWINGS FOR PROPER COORDINATION WITH OTHER TRADES. 4. VERIFY MECHANICAL UNIT LOCATIONS. IF UNITS ARE NOT PLACED WHERE INDICATED ON THIS PLAN CONTACT THE STURTURAL ENGINEER PRIOR TO TRUSS FABRICATION. 5. COORDINATE ATTIC VENTING REQUIREMENTS WITH ARCHITECTURAL DRAWINGS. 6. ELEVATOR HOIST BEAMS HAVE BEEN DESIGNED TO SUPPORT 7.5 KIP LOADS AT ANY LOCATION ALONG BEAM. SEE DETAILS FOR HOIST BEAM & RAIL COLUMN CONNECTIONS. ROOF FRAMING PLAN NOTES 1 A A D E 2 3 4 5 6 7 8 9 10 DR-5DR-5DR-2DR-5DR-4DR-5DR-1DR-1DR-4 DR-3DR-2ROOF SNOW DRIFT SCHEDULE 40 PSFDR-1 DR-4 DR-5 MARK SURCHARGE, Pd 46 PSF 8 PSF DRIFT WIDTH, W 9'-0" 20'-0" 5'-0" DR-2 51 PSFDR-3 12'-0" NOTES: 1. SEE SNOW DRIFT PLAN FOR PLAN FOR DRIFT LOCATIONS AND EXTENTS. 2. SNOW DRIFT SURCHARGE, Pd, IS ADDITAVE TO THE FLAT ROOF SNOW LOAD, Pf, INDICATED IN THE GENERAL STRUCTURAL NOTES AS SHOWN IN THE DIAGRAM BELOW: 27 PSF 12'-6" Pf Pf 3/8"Pd 1 7/ 8" W ROOF JOIST SCHEDULE, UNO 2x8 @ 24" OCRJ1 14" RED-I45 @ 24" OCRJ2 RJ3 RJ4 LVL1 3/4x14 LVL3 1/2x14 RJ5 14" RED-I65 @ 24" OC RJ6 2-14" RED-I65 @ 24" OC 737 BISHOP STREET, SUITE 1860 HONOLULU, HI 96813 808-352-5299 OWNER: 523 EAST THIRD AVENUE SPOKANE, WA 99202 P 509.323.9292 F 509.747.7115 HOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 99216ROOF FRAMING PLAN - WEST WING S128 FSC PROJECT NO. 21012 PERMIT SET 5/31/2024 GL8 Mirabeau Point, LLC 10909 E. Pierce Lane Spokane, WA 99206 (509) 919-0901 NORTHSCALE:1/8" = 1'-0" ROOF FRAMING PLAN - WEST WING SCALE:3/64" = 1'-0" SNOW DRIFT PLAN Revision Schedule Number Description Date E F G H J K L L M N P 4 5 6 6 7 7 8 8 9 9 C.1 L.1 Q 10 1060'-3 1/2"23'-11 5/8"6'-1 1/4"24'-2 5/8"6'-0"6 S501 __________ 9 S501 __________ 6 S501 __________ 6 S501 __________ 7 S501 __________ 6 S501 __________ 6 S501 __________54'-3 1/2"TYP 5/8" APA RATED SHTGRJ2RJ2RJ2RJ2RJ2RJ2RJ2RJ2RJ2RJ2RJ2RJ5RJ5RJ2RJ2RJ2RJ2RJ2RJ2RJ2RJ2RJ1RJ1 19'-0 7/8"19'-0 3/4"19'-1"19'-0 7/8"19'-0 3/4"14'-11"19'-1 1/2"10'-9"14'-11 1/4"19'-1 1/2"19'-9 1/8" 4'-2 5/8" 193'-11 5/8" __________ S502 2 TYP @ WALL OFFSET 16 S501 __________ 2 2 2 2RJ5 RJ5 RJ4 2 RJ5 RJ5 RJ3 RJ2 RJ3 RJ2 RJ3 RJ2 RJ3 RJ2 2 RJ4 RJ4 2 RJ4 2 1 S502 __________ TYP @ INTERIOR BRG WALLS __________ S502 3__________ S502 3 __________ S502 3 __________ S502 3 __________ S502 3 RJ5 RJ5 RJ5 RJ5 ERV-01 6,500# CU-02 1,500# CU-03 1,500# RJ4RJ4 RJ2 RJ2RJ219 S501 __________ 14 S501 __________ 14 S501 __________17 S501 __________ 17 S501 __________RJ6 RJ6 RJ6 RJ6 RJ6 RJ6 RJ6 RJ6 RJ5RJ5GL5 1/2x14 GL5 1/2x14 HSS8x4x1/4 HSS8x4x1/4 (62'-10") (62'-10") HSS8x4x1/4 (62'-10") W8x18, 2 PLCS (62'-10"), SEE NOTE 6 11 S502 __________ 13 S502 __________ 1. SEE S0-SERIES SHEETS FOR GENERAL STRUCTURAL NOTES, ABBREVIATIONS, LEGEND & TYPICAL DETAILS. 2. COORDINATE AND VERIFY ALL DIMENSIONS WITH ARCHITECTURAL DRAWINGS. 3. REFER TO ALL ARCHITECTURAL, ELECTRICAL, & MECHANICAL DRAWINGS FOR PROPER COORDINATION WITH OTHER TRADES. 4. VERIFY MECHANICAL UNIT LOCATIONS. IF UNITS ARE NOT PLACED WHERE INDICATED ON THIS PLAN CONTACT THE STURTURAL ENGINEER PRIOR TO TRUSS FABRICATION. 5. COORDINATE ATTIC VENTING REQUIREMENTS WITH ARCHITECTURAL DRAWINGS. 6. ELEVATOR HOIST BEAMS HAVE BEEN DESIGNED TO SUPPORT 7.5 KIP LOADS AT ANY LOCATION ALONG BEAM. SEE DETAILS FOR HOIST BEAM & RAIL COLUMN CONNECTIONS. ROOF FRAMING PLAN NOTES E F G H J K L M N P 5 6 7 8 9 Q 10 DR-5 DR-5 DR-5DR-1 DR-1 DR-1DR-1 DR-4DR-1 DR-3DR-1DR-1DR-1 DR-1 DR-1 ROOF SNOW DRIFT SCHEDULE 40 PSFDR-1 DR-4 DR-5 MARK SURCHARGE, Pd 46 PSF 8 PSF DRIFT WIDTH, W 9'-0" 20'-0" 5'-0" DR-2 51 PSFDR-3 12'-0" NOTES: 1. SEE SNOW DRIFT PLAN FOR PLAN FOR DRIFT LOCATIONS AND EXTENTS. 2. SNOW DRIFT SURCHARGE, Pd, IS ADDITAVE TO THE FLAT ROOF SNOW LOAD, Pf, INDICATED IN THE GENERAL STRUCTURAL NOTES AS SHOWN IN THE DIAGRAM BELOW: 27 PSF 12'-6" Pf Pf 3/8"Pd 1 7/ 8" W ROOF JOIST SCHEDULE, UNO 2x8 @ 24" OCRJ1 14" RED-I45 @ 24" OCRJ2 RJ3 RJ4 LVL1 3/4x14 LVL3 1/2x14 RJ5 14" RED-I65 @ 24" OC RJ6 2-14" RED-I65 @ 24" OC STRAP SCHEDULE STRAP NOTES: 1. CMST14 MIN LAP SPLICE LENGTH = 14" (13-0.162x2 1/2" NAILS) 2. SHORTER NAIL SUBSTITUTIONS ARE NOT ALLOWED @ STRAP SPLICES. 3. IF WOOD SPLITTING OCCURS, DOUBLE THE LAP SPLICE LENGTH (OR STRAP LENGTH FOR ) AND USE EVERY OTHER ROUND NAIL HOLE. 4. NO STRAP MODIFICATION IS ALLOWED. 5. INSTALL STRAPS TIGHT, WOOD SHRINKAGE AFTER STRAP INSTALLATION ACROSS HORIZONTAL WOOD MEMBERS MAY CAUSE STRAP TO BUCKLE OUTWARD. 6. STRAPS INSTALLED OVER SHTG REQ 2 1/2" LONG NAILS MIN. STRAPMARK LSTA18 LSTI73 CMST14-2'-8" 1 2 3 4 5 6 7 CMST14-12'-0" CMST14-20'-0" CS14xCONT (AS SHOWN) CMST14xPLAN DIM 3 737 BISHOP STREET, SUITE 1860 HONOLULU, HI 96813 808-352-5299 OWNER: 523 EAST THIRD AVENUE SPOKANE, WA 99202 P 509.323.9292 F 509.747.7115 HOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 99216ROOF FRAMING PLAN - EAST WING S129 FSC PROJECT NO. 21012 PERMIT SET 5/31/2024 GL8 Mirabeau Point, LLC 10909 E. Pierce Lane Spokane, WA 99206 (509) 919-0901 NORTHSCALE:1/8" = 1'-0" ROOF FRAMING PLAN - EAST WING SCALE:3/64" = 1'-0" SNOW DRIFT PLAN Revision Schedule Number Description Date T.O.B. T.O.B. E F G H J 5 5 6 6C558C558C558C558C558C558C558 W16x26 W16x26 W18x35 3" 6'-1" 6'-3" 6'-3" 6'-3" 6'-3" 6'-3" 6'-1" 3" 1½"x20GA TYPE 'B' STL ROOF DECK, GALV W18x35 16 S401 __________ 18 S401 __________W21x68W21x68W21x68W21x68 1 S402 __________ 17 S401 __________17 S401 __________ W16x26 5 S402 __________ 4 PLCS W18x35 W18x35 W18x35 19 S401 __________ 3 S402 __________C558T.O.S. 0" T.O.F. -2'-0" E F G H J HSS7x5x1/2HSS5x5x1/2HSS5x5x1/2HSS7x5x1/2HSS5x5x1/4HSS5x5x3/8 HSS5x5x3/8 HSS5x5x3/8 HSS5x5x3/8 W16x26 W16x26 W21x68 W16x26 W18x35 W21x68W21x68 HGRS @ 4'-0" OC MAX (TYP) W21x68 HSS5x5x1/217 S401 __________18 S401 __________17 S401 __________ (15'-6 1/4") HSS5x5x3/8 HSS5x3x1/4 W21x68 19 S401 __________ __________ S007 19 TYP T.O.F. -2'-0" EFGHJ HSS5x5x1/4HSS5x5x1/4W21x68 W21x68HSS5x5x1/2HSS5x5x1/2HSS5x5x1/2HSS5x5x1/2HSS5x5x1/2HSS5x5x1/2HSS5x5x1/2HSS5x5x1/2W18x35 W18x35 W18x35 (13'-6") __________ S007 3 HSS5x5x1/4 GIRT BEYOND BTWN COLS (TOP @ 13'-0") __________ S007 3 CANOPY FRAMING IN FOREGROUND BALCONY FRAMING IN FOREGROUND 17 S401 __________17 S401 __________ 1 S402 __________ W21x68 __________ S402 5__________ S402 5 __________ S402 5 __________ S402 5 W21x68 BEYOND __________ S402 3 __________ S402 3 OPP 737 BISHOP STREET, SUITE 1860 HONOLULU, HI 96813 808-352-5299 OWNER: 523 EAST THIRD AVENUE SPOKANE, WA 99202 P 509.323.9292 F 509.747.7115 HOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 99216CANOPY FRAMING PLAN & STEEL FRAME ELEVATIONS S130 FSC PROJECT NO. 21012 PERMIT SET 5/31/2024 GL8 Mirabeau Point, LLC 10909 E. Pierce Lane Spokane, WA 99206 (509) 919-0901 SCALE:1/8" = 1'-0"1 NORTH LOBBY CANOPY FRAMING PLAN SCALE:1/8" = 1'-0"3 NORTH CANOPY INTERIOR FRAMING ELEVATION SCALE:1/8" = 1'-0"5 NORTH CANOPY EXTERIOR FRAMING ELEVATION Revision Schedule Number Description Date T.O.F. T.O.S. GRID T.O.F. T.O.S. GRID T.O.S. T.O.F. T.O.S. T.O.F. T.O.S. T.O.F. T.O.S. T.O.F. FINISH GRADE T.O.S. T.O.C. T.O.F. TYP ELEVATOR COLUMN BASE CONN 8" CONC 2'-4" 2x6 STUDS SEE PLAN 1" (V) 2x6 STUDS SEE PLAN PLAN DIM 2'-4" 2x6 STUDS SEE PLAN 4" (V) PLAN DIM 1'-0" CONC W/ 2x6 STUDS SEE PLAN HSS COL SEE PLAN T.O.F. Px-x T.O.S. Px-x T.O. HSS (V) T.O. HSS (V) T.O. HSS (V) eTYP -5'-0" SEE F.O. CONC SEE PLAN (V) SEE PLAN F.O. CONC (V)V #4 @ 12" OC H #4 @ 10" OC EACH FACE EMBED lyx12x1'-0" W/ 4-s"∅x5" HAS HSS BEAMS @ RAIL SUPPORTS COORD & (V) LOCATIONS W/ ELEVATOR MFR. NOTE: SEE TYP HSS TO COL DETAIL FOR CONNECTION OF HSS RAIL BEAMS, TYP THICKENED SLAB SEE 8/S301 lix5ix0'-11" W/ 2-p"_x8" TITEN HD @ 8" OCFROST DEPTH (MIN)STEM WALL CTR ON3" CLR8" CONC STEM WALL #4 V @ 16" OC (CNTRD) #4 H @ 10" OC (3 MIN) FOOTING SEE PLAN FOR SIZE & REINF SUBGRADE PREP PER GEOTECH REPORT ALT HOOK IN FTG F.O. CONC AS OCCURS 2x6 STUDS SEE PLAN 2x PT PLATE W/ 5/8"Ø AB PER SHEARWALL SCHED OR 48" OC MAX (7" EMBED) EXTR WALL FINISH SEE ARCHL SLAB POUROVER @ STOREFRONT & DOORS PER TYP DETAIL SEE PLAN Px-x SEE PLAN FROST DEPTH (MIN)STEM WALL CTR ON3" CLR10" CONC STEM WALL #4 V @ 12" OC (CNTRD) #4 H @ 10" OC (3 MIN) FOOTING SEE PLAN FOR SIZE & REINF SUBGRADE PREP PER GEOTECH REPORT ALT HOOK IN FTG SLAB POUROVER @ STOREFRONT & DOORS PER TYP DETAIL 2x8 STUDS SEE PLAN 2x PT PLATE W/ 5/8"Ø AB PER SHEARWALL SCHED OR 48" OC MAX (7" EMBED) EXTR WALL FINISH SEE ARCHL SEE PLAN Px-x F.O. CONC AS OCCURS SEE PLAN NOTES: 1. USE BASE PL3/4 ON 1 1/2" NON-SHRINK GROUT W/ 15/16"⌀HOLES FOR TAS 2. USE EMBED L6x4x1/2 LLH W/ A. 2-5/8"⌀x6" HAS B. 2-1/2"⌀x1'-0" DBA C. 4-3/4"⌀TAS @ BASE PL 3" MIN 1/4"1 1/2"1 1/2"MIN 5 1/2" TAS 3" MIN 1/4" MIN 5 1/2" TAS 1 1/2"1 1/2"BLDG INTERIOR 1 1/2"1 1/2" TAS 3" MIN 5 1/2" MIN 1/4" BLDG INTERIOR 1"2"2"4"4"1'-0"HAS DBA CL COL & EMBED 1'-0"1'-0"BLDG INTERIOR BLDG INTERIOR 11"BASE PL BASE PL BASE PL EMBED PLAN -STRAIGHT WALL EMBED PLAN -INSIDE CORNER EMBED PLAN -OUTSIDE CORNER STEM WALL & FOOTING (SEE PLANS & DETAILS)4" 2TYP 1/4 HSS COL SEE NOTE 1 CL COL CL STUD F.O. CONC 11" NOTE: CONTRACTOR MAY REPLACE CAST-IN ANCHOR BOLTS WITH TITEN HD SCREWS OR ADHESIVE ANCHORS OF SAME DIAMETER, SPACING, & EMBED. CTR ON WALL SEE PLAN PLANSEECONT REINF PER SCHED (SEE PLAN @ RIGHT)CLR3"#4 @ 24" OC CLR1 1/2"2x PT PLATE W/ 5/8"Ø AB PER SHEARWALL SCHED OR 48" OC MAX (7" EMBED) -SEE NOTE Px-x SEE PLAN WOOD STUDS SEE PLAN SUBGRADE PREP & BEARING CONDITIONS UNDER THICKENED SLAB SECTION SHALL BE SAME AS FOR BLDG FOUNDATION (SEE GEOTECH REPORT) 1'-6" MIN 2'-0" MIN LAPSLAB THICKENED5"PLAN @ INTERSECTING STEM WALLS CONT REINF FDN STEM WALL (SEE PLAN & DTLS) #4x3'-0" AD @ EA SLAB BAR STEM WALL CTR ON3" CLR8" CONC STEM WALL #4 V @ 16" OC (CNTRD) #4 H @ 10" OC (3 MIN) FOOTING SEE PLAN FOR SIZE & REINF SUBGRADE PREP PER GEOTECH REPORT ALT HOOK IN FTG WOOD STUDS SEE PLAN 2x PT PLATE W/ 5/8"Ø AB PER SHEARWALL SCHED OR 48" OC MAX (7" EMBED) SEE PLAN Px-x TYP 1" REINF SLAB EDGE PER TYP DETAIL 1"8"__________ S004 19 SLAB POUROVER @ INTERIOR DOOR FRAMED WALL BEYOND ℄COL & FTG FTG, SEE PLAN SEE PLAN HSS COL CLR3"CONC PIER 2'-0" SQUARE #4 TIES 12-#5 VERT CONC PAVING AS OCCURS 2" CLR 2'-0" MINTYP8" 3"2"2'-4"2" CLR3" CLR1'-6"2'-4" (V) PLAN DIM8" CONC (3) SIDES W/ V #4 @ 12"OC H #4 @ 10"OC CENTER REINF 2-#5 CONT 2x PT PLATE W/ 5/8"Ø AB PER SHEARWALL SCHED OR 48" OC MAX (7" EMBED) SEE NOTE 1 SEE TYPICAL DETAIL FOR SLAB EDGE AT DOORS STUD WALL BEYOND SEE PLAN Px-x 2x6 STUDS SEE PLAN (V) 2 3/4" F.O.C. #6 @ 12" OC EA WAY TOP & BOT 6"1'-6" SQ VERIFY 1 1 1'-6" 3-#4 EW 8"(V)1'-6"CONDITION @ SUMP NOTES: 1. COORDINATE SILL DETAIL W/ ELEVATOR MFR 2. CONTRACTOR SHALL PROVIDE & LOCATE SUMP PIT, GRATE, EMBEDS, & LADDER AS REQ'D BY ELEVATOR MFR. 737 BISHOP STREET, SUITE 1860 HONOLULU, HI 96813 808-352-5299 OWNER: 523 EAST THIRD AVENUE SPOKANE, WA 99202 P 509.323.9292 F 509.747.7115 HOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 99216FOUNDATION DETAILS S301 FSC PROJECT NO. 21012 PERMIT SET 5/31/2024 GL8 Mirabeau Point, LLC 10909 E. Pierce Lane Spokane, WA 99206 (509) 919-0901 SCALE:3/4" = 1'-0"1 SCALE:3/4" = 1'-0"2 SCALE:3/4" = 1'-0"3 SCALE:3/4" = 1'-0"8SCALE:3/4" = 1'-0"6 SCALE:3/4" = 1'-0"10 SCALE:3/4" = 1'-0"16 S301/16 - WFT-6 SCALE:3/4" = 1'-0"18 S301/18 - WFT-8 Revision Schedule Number Description Date SEE ARCH SEE ARCH T.O. SHTG WOOD STUDS SEE PLAN 5 1/ 2" WOOD STUDS SEE PLAN I-JST PER PLAN W/ SIMPSON DGT FIRE WALL HGR WEB STIFF TOPPING PER ARCHL SEE SHEAR WALL SCHED FOR BOT PLATE NAILING SEE PLAN Px-x SEE PLAN Px-x DBL TOP PLATE BELOW FLR SHTG EN EN SEMI-BALLOON FRAMING T.O. SHTG PARTIAL WALL PROFILE ALIGN STUDS ABOVE FLOOR LEVEL W/ STUDS BELOW OFFSET 1 1/2" MAX DBL TOP PLATE BOTTOM PLATE T.O. SHTG WOOD STUDS SEE PLAN 5 1/ 2" WOOD STUDS SEE PLAN 5 1/ 2" TOPPING PER ARCHL SEE SHEAR WALL SCHED FOR BOT PLATE NAILINGSEE PLAN Px-x SEE PLAN Px-x DBL TOP PLATE BELOW FLR SHTG EN EN 4-8d INTO BLKG 2x4 MIN FLAT BLKG @ 24" OC CONT 2x6 MIN LEDGER OVER GYPBOARD W/ SIMPSON SDWS 0.22x5" TIMBER SCREWS @ 12" OC SEMI-BALLOON FRAMING I-JST T.O. SHTG WOOD STUDS SEE PLAN 5 1/ 2" WOOD STUDS SEE PLAN 5 1/ 2" TOPPING PER ARCHL SEE SHEAR WALL SCHED FOR BOT PLATE NAILING SEE PLAN Px-x SEE PLAN Px-x I-JST PER PLAN W/ WEB STIFF PER MFR (SEE PLAN @ RIGHT) 1 1/2" LVL/LSL BLKG BTWN JOISTS (FACE NAIL TO RIM W/ 2-ROWS 10d @ 6" OC) CONT 1 1/2" LVL/LSL RIM @ WALL CL (SEE SHEAR WALL SCHED FOR BOT CLIP @ WALL PL) WALL CL PLAN VIEW BELOW WALL FLR JST FLR JST FLR JST FLR JST FLR JST FLR JST CONT RIM @ WALL CL NAILED TO JOIST FLANGES ON ONE SIDE PER MFR BLKG BTWN JOISTS THAT ARE NOT NAILED TO RIM (OR AS REQ'D FOR BOT PL NAILING) W8 JST W BM STRAP PL1/4x3x2'-0" 3/16 L3x2 1/2x1/4x0'-5" (LLH) EA SIDE3/16 3'-11" L3x3x1/4 CONT 3/16 END PL1/4 W8 JST 1'-0" W8 JST HSS5x3x1/4 HGRS @ 4'-0" OC MAX (SEE FRAME ELEV) PL1/4x3" SQ EA SIDE 2"I-JST PER PLAN STOREFRONT (SEE ARCHL) SEE PLAN WOOD STUDS STIFF PL EA SIDE @ HSS HGRS 3/16 ALL SIDES 3/16 HSS WALL-GIRT HANGERS T.O. SHTG 2x6 BLKG @ 24" OC W/ JB26 HGR EA END STUDS & SHTG TO MATCH WALL ABOVE BALCONY AS OCCURS __________ S401 3 2 ROWS 10d @ 8" OC STAGGERED DBL 2x6 NAILER W/ 5/8"ø HAS @ 24" OC W BEAM INFILL W/ 2x6 STUDS @ 16" OC (FASTEN TOP & BOT PLATES W/ SIMPSON TF SCREWS @ 16" OC SEE DTL ABOVE FOR HANGERS & BRACES CANOPY FRAMING AS OCCURS HSS5x5 WALL GIRT (SEE FRAME ELEV) W BEAM HSS WALL GIRTMAX1/2"L3x3x1/4 CONT SEE ABOVE 3/16 SIMPSON TF SCREW @ 16" OC (ALT SIDES) W BEAM JST-TO-BM CONN __________ S007 13 L3x3x1/4 BRACE @ EA HSS HGR W/ 2" LAP EA END 3/16 3-12 CONT L3x3 W BEAM 3/16EA END __________ S401 6 T.O. SHTG I-JST PER PLAN W/ WEB STIFF PER MFR AS NEEDED W BEAM ITS HGR WOOD STUDS SEE PLAN (AS OCCURS) 5 1/ 2" SEE SHEAR WALL SCHED FOR BOT PLATE NAILING SEE PLAN Px-x TOPPING PER ARCHL DBL 2x NAILER W/ 5/8"ø TAS @ 24" OC (SEE DTL @ RIGHT) Bf UP TO 7 1/2" Bf Bf UP TO 11 1/2" Bf 1 1/2"1 1/2" CL W BEAM TAS @ CL BM NOTES: 1. NAILERS SHALL BE RIPPED FROM SOLID LUMBER TO FIT WIDTH OF BEAM FLANGE TO WITHIN 1/8" MAX UNDER OR OVER EACH SIDE. 2. CONNECT PLATES W/ 10d @ 6" OC, ALTERNATING SIDES OF BEAM CL. TAS ALT SIDES OF BEAM CL SEE NOTE 2 SEE NOTE 1 W BEAM W8 JST SEE PLAN WOOD STUDS T.O. SHTG I-JST PER PLAN 2 ROWS 10d @ 8" OC STAGGERED PONY WALL W/ 2x6 STUDS @ 16" OC W BEAM BEYOND W BEAM W/ STIFF PL EA SIDE @ HSS HGRS HSS5x5 WALL GIRT HSS5x3 HGRS SEE FRAME ELEV & DTL 17/S4.01 5/8"ø HAS @ 16" OC __________ S402 1 __________ S401 17 L3x3x1/4 BRACE @ EA HSS HGR (SEE DTL 17/S4.01) __________ S401 17 T.O. SHTG SEE PLAN WOOD STUDS __________ S401 17 I-JST PER PLAN STUDS & SHTG TO MATCH WALL ABOVE SIMPSON TF SCREW @ 16" OC (ALT SIDES) W BEAM 3-12HSS5x5x3/8 CONT (SEE ABOVE) W BEAM SEE PLAN WOOD STUDS STAGGER SHEAR WALL EDGE NAILING CONT DBL TOP PLATES INDIVIDUALLY FASTENED TOP PLATE W/ 2 ROWS TF SCREWS @ 8" OC (STGRD) BOT PLATE W/ 2 ROWS 10d @ 8" OC (STGRD) HSS COL DETAIL @ EACH END OF HSS5x5 CONT HSS5x5 W BEAM W BEAM L4x4x3/8 x0'-5" MAX 1/2" 1/4 __________ S007 13 737 BISHOP STREET, SUITE 1860 HONOLULU, HI 96813 808-352-5299 OWNER: 523 EAST THIRD AVENUE SPOKANE, WA 99202 P 509.323.9292 F 509.747.7115 HOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 99216FLOOR FRAMING DETAILS S401 FSC PROJECT NO. 21012 PERMIT SET 5/31/2024 GL8 Mirabeau Point, LLC 10909 E. Pierce Lane Spokane, WA 99206 (509) 919-0901 SCALE:3/4" = 1'-0"1 SCALE:3/4" = 1'-0"3 SCALE:3/4" = 1'-0"4 SCALE:3/4" = 1'-0"16 SCALE:3/4" = 1'-0"17 SCALE:3/4" = 1'-0"6 SCALE:3/4" = 1'-0"18 SCALE:3/4" = 1'-0"19 Revision Schedule Number Description Date 6 6 W BM BEYOND CONT BENT PL3/8 5"3 " 362S162-43 SOFFIT JST @ 16" OC362S162-43 SOFFIT JST @ 16" OC W BM W BM 5'-1" W BM W BM W BEAM SECTION VIEWEND VIEW 4-3/4"ø HSB @ BM GAGE STIFF PL EA SIDE @ BM CL W BEAM STIFF PL EA SIDE @ BM CL CONTINUOUS W BEAM STIFF PL 3/8 EA SIDE 2" CLR 2" CLR 1/4 HSS5x5x1/2 STUB COL BASE PL 5/8 W/ 4-3/4"ø HSB STIFF PL 3/8 EA SIDE NOTE: IT IS ACCEPTABLE TO PROVIDE SSL HOLES IN BEAM FLANGE, PARALLEL WITH BEAM. SEE NOTE W BEAM BASE PLATE 1 1/2" 1 1/2"6"1 1/4"1/4 BM CL MIN6"STUB COL 2 3/4" SEE PLAN W BEAM SECTION VIEWEND VIEW BASE PLATE .1 1/2"6"1 1/4"1/4 TYP COL & STIFF PL PLAN W BEAM HSS COL __________ S007 1 W BEAM EA SIDE 1 1/2"SPLIT HSS5x5x1/2 EA SIDE __________ S007 61/4 L4x4x3/8 EA SIDE W/ 6-3/4"ø HSB W BEAM 3"1 1/2".1 1/2" 4" 1/4 EA ANGLE STIFF PL @ CL COLS W BEAM BASE PL 5/8 W/ 6-3/4"ø HSB STIFF PL 3/8 DBL HSS COLS 4"BALCONY FRAMING SEE DTLS SEE NOTE __________ S007 8 NOTE: IT IS ACCEPTABLE TO PROVIDE SSL HOLES IN BEAM FLANGE, PARALLEL WITH BEAM. SECTION VIEWEND VIEW CONTINUOUS W BEAM BALCONY FRAMING SEE DTLS HSS COL __________ S007 11 W16x26 W BEAM SEE TYP DETAILS HSS COL 737 BISHOP STREET, SUITE 1860 HONOLULU, HI 96813 808-352-5299 OWNER: 523 EAST THIRD AVENUE SPOKANE, WA 99202 P 509.323.9292 F 509.747.7115 HOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 99216FLOOR FRAMING DETAILS S402 FSC PROJECT NO. 21012 PERMIT SET 5/31/2024 GL8 Mirabeau Point, LLC 10909 E. Pierce Lane Spokane, WA 99206 (509) 919-0901 SCALE:3/4" = 1'-0"11 SCALE:3/4" = 1'-0"13 SCALE:3/4" = 1'-0"15 SCALE:3/4" = 1'-0"1 SCALE:3/4" = 1'-0"3 SCALE:3/4" = 1'-0"5 Revision Schedule Number Description Date GRID T.O.P. GRID J.B. GRID GRID T.O.P. GRID T.O.P. F.O. STUD AS OCCURS PARAPET CAP SEE ARCHL DBL 2x6 TOP PL 2x6 BLKG EN 2x6 BLKG @ 16" OC, ALIGN W/ STUDS (PROVIDE BLKG 3 BAYS IF FIRST BAY IS LESS THAN 16") LSL1 1/2x14 LEDGER W/ 3-SDWS22500 EA STUD & 16d @ 6" OC TO 2x6 BLKG H2A 8d @ 4" OC 2"4" 4" EN LTS12 EA STUD F.O. STUD AS OCCURS PARAPET CAP SEE ARCHL DBL 2x6 TOP PL H2A EA STUD 8d @ 4" OC 2x6 KICKER EA SIDE OF STUD CONT ROOF PL1/4x8 W/ 2-ROWS SDS25400 @ 16" MAX OC (STGRD, 8" OC NET) SEE PLAN SIDE PL3/16 W/ 2-SDS25200 2-SDWS22400 EA SIDE (4 TOTAL, STGR SCREWS FS) 1 1/2"1 1/2"1 1/2"1 1/2"1 1/2"3"1 1/2"1 1 1/8 1/8 SIDE PL WELDS MSTA49 (FILL EVERY OTHER NAIL HOLE) 5 1/ 2" WOOD STUDS SEE PLAN AS OCCURS SEE PLAN Px-x 5 1/ 2" WOOD STUDS SEE PLAN I-JST PER PLAN 1 3/4" LVL/LSL RIM (SEE SHEAR WALL SCHED FOR CONNECTION INFO & ADDL BLKG) 2x JST PER PLAN LUS28 EA END ENEN DBL 2x6 TOP PL EN 2x6 BLKG @ 24" OC LSL1 1/2x14 LEDGER W/ 3-SIMPSON SDWS22500 EA STUD & 16d @ 6" OC TO 2x6 BLKG 12" OC F.O. STUD SEE PLAN SEE PLAN 2x12 OUTLOOKER EN SEE FOR ADDL INFORMATION__________ S501 9 LVL5 1/4x14 BLKG SP6 EA STUD 2-ROWS SDWS TIMBER SCREWS @ 16" OC (STGRD, 8" OC NET) SDWS22600 TOP SIDE & SDWS22800 BOT SIDE LTP5 @ 16" OC F.O. STUD AS OCCURS PARAPET CAP SEE ARCHL DBL 2x6 TOP PL WOOD PARAPET STUDS SEE PLAN SEE PLAN Px-x 5 1/ 2" I-JST LSL1 1/2x14 RIM BOARD WEB STIFF2'-0"CS20 STRAP EA STUD (NOT REQUIRED @ SIM)9"9"WOOD STUDS SEE PLAN 5 1/ 2" 5 1/ 2" 2x6 BRACE EA STUD (NOT REQUIRED @ SIM) SEE NOTE CS20 STRAP W/ 10" MIN END LENGTH EA FACE OF STUD 10"NOTES: 1. ALIGN PARAPET STUDS WITH WALL STUDS BELOW TO ACCOMODATE COIL STRAP 2. SHEATH BACK SIDE OF PARAPET AND 2x6 BRACE W/ 5/8" APA RATED ROOF SHTG 4x6 BLKG W/ 2-A34 EA END A34 SDWS22600 @ 8" OC F.O. STUD AS OCCURS PARAPET CAP SEE ARCHL DBL 2x6 TOP PL WOOD PARAPET STUDS SEE PLAN SEE PLAN Px-x I-JSTLVL5 1/4x14 BLKG WEB STIFF2'-0"WOOD STUDS SEE PLAN 5 1/ 2" 2x6 BRACE EA STUD SEE NOTE CS20 STRAP W/ 10" MIN END LENGTH EA FACE OF STUD 10"SP6 EA STUD 2-ROWS SDWS TIMBER SCREWS @ 16" OC (STGRD, 8" OC NET) SDWS22600 TOP SIDE & SDWS22800 BOT SIDE 5 1/ 2" LTP5 @ 16" OC 4x6 BLKG W/ 2-A34 EA END A34 SDWS22600 @ 8" OC 737 BISHOP STREET, SUITE 1860 HONOLULU, HI 96813 808-352-5299 OWNER: 523 EAST THIRD AVENUE SPOKANE, WA 99202 P 509.323.9292 F 509.747.7115 HOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 99216ROOF FRAMING DETAILS S501 FSC PROJECT NO. 21012 PERMIT SET 5/31/2024 GL8 Mirabeau Point, LLC 10909 E. Pierce Lane Spokane, WA 99206 (509) 919-0901 SCALE:3/4" = 1'-0"6 SCALE:3/4" = 1'-0"7 SCALE:3/4" = 1'-0"19 SCALE:3/4" = 1'-0"9 SCALE:3/4" = 1'-0"14 SCALE:3/4" = 1'-0"16 SCALE:3/4" = 1'-0"17 Revision Schedule Number Description Date J.B. TYP T.O. HSS COLUMN 2x6 STUDS SEE PLAN 2x6 STUDS SEE PLAN 2x6 STUDS SEE PLAN T.O.W. VARIES T.O.B. 61'-2" 62'-10" HSS COLS BEYOND T.O. JOIST 2x8 HSS BOLTED CONN TO WALL TOP l'S SEE DETAIL 21 W8 HOIST BEAM (V) ELEVATION & LOCATION W/ ELEVATOR MFR HSS BEAM IN WALL BEYOND TYP HSS BEAM TO COL 1/2" CLR 2x6 STUDS SEE PLAN 2x6 STUDS SEE PLAN 2x6 STUDS SEE PLAN T.O. HSS (V) W8 W8 T.O.B. TYP T.O. HSS (V) 65'-6" 62'-10" T.O.P. HSS BEAMS @ RAIL SUPPORTS COORD & (V) LOCATIONS W/ ELEVATOR MFR. NOTE: SEE TYP HSS TO COL DETAIL FOR CONNECTION OF HSS RAIL BEAMS, TYP SEE TYPICAL BOLTED STEEL CONNECTION DETAIL, TYP HSS BEAMS @ W8 HOIST BEAM COORD & (V) LOCATIONS W/ ELEVATOR MFR. SEE TYPICAL WOOD STUD ATTACHMENT TO COLUMN FOR SIM CONNECTION, TYP HSS BEAM m4x3 PER HSS BEAM TO COL DETAIL WOOD STUDS SEE PLAN5 1/ 2" SEE PLAN Px-x I-JST PER PLAN W/ WEB STIFF PER MFR AS NEEDED 1 1/2" LVL/LSL BLKG (SEE SHEAR WALL SCHED FOR CONNECTION INFO & ADDL BLKG) EN ROOF JST PER PLAN 1 3/4" RIM BOARD 2-ROWS SDWS22500 @ 6" OC (ALT SIDES & STGR ROWS, 10 SCREWS TOTAL) 3" 4 SPCS @ 6" 3" 1 3/4x14x2'-6" LVL/LSL SPACER BLKGPRIVATE ROOMCOORIDOOR1 3/4" RIM BOARD19 S501 __________ INTERIOR OFFSET WALL PLAN LVL JST PER PLAN 6 S501 __________ EXTERIOR OFFSET WALL PLAN STRAP PER PLAN BLKG PER PLANS & DTLS 1 S502 __________ I-JST PER PLAN LEDGER NOTES: 1. BUTT LEDGER TIGHT TO LVL JOIST & CENTER STRAP ON JOINT. 2. 2x LEDGERS THAT ARE STRAPPED @ WALL OFFSETS SHALL BE CONTINUOUS BETWEEN INTERIOR BEARING WALL LINES. EXTERIOR BALLOON FRAMED WALLS INT BRG WALL BELOW 737 BISHOP STREET, SUITE 1860 HONOLULU, HI 96813 808-352-5299 OWNER: 523 EAST THIRD AVENUE SPOKANE, WA 99202 P 509.323.9292 F 509.747.7115 HOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 99216ROOF FRAMING DETAILS S502 FSC PROJECT NO. 21012 PERMIT SET 5/31/2024 GL8 Mirabeau Point, LLC 10909 E. Pierce Lane Spokane, WA 99206 (509) 919-0901 SCALE:3/4" = 1'-0"1 SCALE:3/4" = 1'-0"2 SCALE:3/4" = 1'-0"3 Revision Schedule Number Description DateSCALE:3/4" = 1'-0"11 SCALE:3/4" = 1'-0"13 GRID HSS8x3x3/16 HSS8x3x3/16 HSS8x4x3/8HSS8x4x3/8HSS8x4x3/8HSS8x4x3/8HSS8x3x3/16HSS8x3x3/16 11 S601 __________ 8 S601 __________8 S601 __________ 14 S601 __________14 S601 __________ SIM HSS8x3x3/16 HSS8x4x3/8HSS8x3x3/16 HSS8x4x3/811 S601 __________ 8 S601 __________ 14 S601 __________ HSS8x3x3/16 HSS8x4x3/8HSS8x4x3/8HSS8x3x3/16 11 S601 __________ 8 S601 __________ 19 S601 __________ T.O. SHTG 400S162-54 STL JOISTS @ 16" OC (UNPUNCHED) W/ CONT TRACKS EA END (FASTEN TRACKS TO HSS W/ PAF @ 16" OC) FLR LEVEL SEE ARCHL NOTE 34 3/4"3 1/2"HSS8x3 3/4" APA-RATED SHTG OVER STL JOISTS (FLUSH W/ T.O. HSS) FASTEN W/ #8 SCREWS @ 6" OC EDGES & FIELD SLOPED CONC TOPPING W/ 6x6-W2.9xW2.9 WWF (SEE NOTE 2) SEE NOTE 1 NOT @ ADA UNITS1/2" STEPCONT L 2 1/2x2 1/2x1/4 EA END OF STL JSTS CONT L 2 1/2x2 1/2x1/4 FLOOR FRAMING SEE PLAN & DTLS 5'-3 1/2" F.O. STUD HSS8x3 3/16 3-12 3-12 3/16 3-12 NOTES: 1. PROVIDE WATERPROOFING MEMBRANE BTWN CONCRETE & WOOD. 2. SEE ARCHL FOR WATERPROOFING SYSTEM ON CONCRETE SURFACE. 3. TOP OF STEEL HSS FRAME IS 4 1/4" BELOW FLOOR LEVEL @ ADA UNITS.2 1/2"2 1/2"PLAN - CONNECTIONS AT HSS FRAME HSS8x4 HSS8x4 HSS8x4 HSS8x4 HSS8x4 HSS8x4 HSS8x3HSS8x3HSS8x3HSS8x3GAP TYP1/2" MAXL 2 1/2x2 1/2x1/4 x0'-4" EA CORNER CAP PL 1/4 @ ALL OPEN ENDS OF HSS MEMBERS (SEAL WELD) 3/16HSS8x4 3/16 3 SIDES HSS8x3 AT DOUBLE BALCONIES 3 1/4" 5"VARIESVARIESBALCONY EDGE CONDITION CNTR CONDITION @ DBL BALCONY HSS8x4 3/16 3-12 3-12 CONT BENT PL 1/4 W/ 1/2"øx4" HAS @ 12" OC 3"2"STEEL EDGE JOIST W/ PAF @ 12" OC CONC TOPPING OVER FRAMING __________ S601 11 HSS8x4 STEEL EDGE JOIST W/ PAF @ 12" OCCONC TOPPING OVER FRAMING __________ S601 11 7"2"CONT PL 1/4 W/ 1/2"øx4" HAS EA SIDE @ 12" OC 3/16 3-12 3/16 3-12 T.O. SHTG I-JST HSS-TO-HSS CONNECTION 1 1/2"3 1/2"2 1/2" 1/4 TOP PL 3/8 TOP PL 3/8 1/4 T&B EA SIDE HSS COL HSS8x4 END PL 1/2 1/4 1"1/2"HSS8x4 1/4 HSS8x4 SEE HSS-TO-HSS CONN ABOVE HSS COL MAX 1/4" SIDE PLATES HSS COL 8d @ 3" OC ALONG BLKG SIDE PLATES SEE BELOW (ALIGN W/ HSS8x4) 1 1/2" PL3/8x8x8 EA SIDE W/ 2-5/8"ø THRU BOLTS @ 5" GA 3/16EA SIDE PL SIMPSON DTT2Z W/ 1/2"ø THRD ROD & 1/4x2 1/2" SDS SCREWS LVL BLKG 3 1/2" LVL FULL-DEPTH BLKG (3 BAYS) A35 CLIPS EA SIDE & EA END OF BLKG (PROVIDE FILLER BLOCK @ JST WEB) HSS COL 4"WALL FINISH HSS8x4 HSS8x4 PLAN AT DBL COLUMN (SIM CONDITION) DBL COLUMN (SIM CONDITION)PLANSEECOMBINED TOP PL 3/8 1 1/2"3 1/2"2 1/2" HSS COLS T.O. SHTG HSS8x4 HSS COL WALL FINISH 4'-6" CL COL __________ S601 14 MAX 1/4" 3 1/2" LVL STRUT TO MATCH JOIST DEPTH 8d @ 3" OC ALONG STRUT (STAGGER) 3 1/2" LVL HEADER BTWN JOISTS SIMPSON HUCQ412 HANGER FLR JST FLR JST LVL HEADER W/ HUCQ412 HGRS LVL STRUT PLAN VIEW FLR JST BEYOND 737 BISHOP STREET, SUITE 1860 HONOLULU, HI 96813 808-352-5299 OWNER: 523 EAST THIRD AVENUE SPOKANE, WA 99202 P 509.323.9292 F 509.747.7115 HOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 99216ENLARGED BALCONY PLANS & DETAILS S601 FSC PROJECT NO. 21012 PERMIT SET 5/31/2024 GL8 Mirabeau Point, LLC 10909 E. Pierce Lane Spokane, WA 99206 (509) 919-0901 SCALE:1/4" = 1'-0"C ENLARGED DOUBLE BALCONY PLAN SCALE:1/4" = 1'-0"A ENLARGED SINGLE BALCONY PLAN - PARALLEL FRAMING SCALE:1/4" = 1'-0"B ENLARGED SINGLE BALCONY PLAN - PERPENDICULAR FRAMING SCALE:3/4" = 1'-0"11 SCALE:3/4" = 1'-0"8 SCALE:3/4" = 1'-0"14 SCALE:3/4" = 1'-0"19 Revision Schedule Number Description Date DDDD WWWW UP UP DN UP DN UP 5 3 3.1 6.1 2.1 D C.1 FG ML.1EC C B B 1 11 EMPLOYEEROOM 110 POOL &SPLASHPAD 101 ELECTRICAL 104 POOL MEP 103 POOLRESTROOM 102 BOHLAUNDRY 105 BOHDRYERS 105A LINENDISCHARGE& SORTING 107 LINENCHUTE 140 ELEVATORLOBBY 117 ELEV 1 111 ELEV 2 113 WATERHEATER &FIRE 108 STAIR 1 106 LAUNDRYLOUNGE 112 FITNESS 114 MEN'SRESTROOM 116 LINENSTORAGE 109 GUESTSTORAGE 118 WOMEN'SRESTROOM 115 8.1 9 4 1.1 A K N P Q 2 LOBBY 121 FOOD PREP 123 PUBLICCORRIDOR 121A GUESTCORRIDOR 139 EFFICIENCY 129 EFFICIENCY 131 EFFICIENCY 133 DOUBLEQUEEN 135 KINGSTUDIOADA-M-T 138 DOUBLEQUEEN 136 EFFICIENCY 134 STAIR 2 132 KINGSTUDIO 130 OPENOFFICE 124 GM OFFICE 125VESTIBULE 122 MEETINGROOM 120 MEETINGSTORAGE 119 SALESOFFICE 126 OWNER'SOFFICE 127 ELECTRICAL 128 COURTYARDSTORAGE 141 VESTIBULE 139A PUBLICCORRIDOR 100 VESTIBULE 100A EMP RRADA 110AEMP RR 110B 7 8 6 10 H J KINGSTUDIO 137 LANAI 137A LANAI 135A 57' - 7" 13 sec 67' - 3" 15 sec 84' - 7" 19 sec 91' - 9" 21 sec 97' - 7" 22 sec L 5 3 3.1 6.1 2.1 D C.1FG ML.1EC C B B 1 8.1 9 4 1.1 A K N P Q 2 KING1-BEDROOMADA-M-T x01 CONNECTINGCORRIDOR x00 KING1-BEDROOM x02 KINGSTUDIO x04 EFFICIENCYENLARGED x03 EFFICIENCY x05 EFFICIENCY x07 LINENS &HOUSEKEEPING x09 EFFICIENCY x08 DOUBLEQUEEN x10 STAIR 1 x06 DOUBLEQUEENENLARGED x12 KINGSTUDIO x14KINGSTUDIO x16 KINGSTUDIO x18 KINGSTUDIO x20 ELEV 1 111 ELEV 2 113 ELEVATORLOBBY x17KINGSTUDIO x19 KINGSTUDIO x21 KINGSTUDIO x23 KINGSTUDIO x25 EFFICIENCY x27 EFFICIENCY x29 EFFICIENCY x31 EFFICIENCY x33 DOUBLEQUEEN x35 KINGSTUDIO x37 KINGSTUDIOADA-M-RI x38 DOUBLEQUEEN x36 EFFICIENCY x34 STAIR 2 x32 KINGSTUDIO x30 EFFICIENCY x28 KINGSTUDIO x26 DOUBLEQUEEN x24 DOUBLEQUEEN x22 GUESTCORRIDOR x15 7 8 6 10 HJ ELECTRICAL X15A BALCONY X35A BALCONY X37A BALCONY X23A BALCONY X25A BALCONY X01ABALCONY X02A BALCONY X19A BALCONY X21A 201' - 2" 46 sec 127' - 11" 29 sec 127' - 4" 29 sec 164' - 0" 37 sec L 48' - 9 1/2" DEAD ENDDEAD END22' - 10"45' - 5 1/4" DEAD END1/2 HOUR FIRE RATED WALL 1 HOUR FIRE RATED WALL 2 HOUR FIRE RATED WALL 1/2 HOUR FIRE RATED CORRIDOR 1 HOUR SMOKE BARRIER AT ELEVATOR LOBBY 2 HOUR FIRE RATED SHAFT THERMAL ENVELOPE BOUNDARY ACCESSIBLE ROOM - MOBILITY ACCESSIBLE ROOM - COMMUNICATION FEATURE CODE LEGEND 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216CODE PLANS A-001 FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 1/16" = 1'-0"11ST FLOOR CODE PLAN 1/16" = 1'-0"2FLOORS 2-5 TYPICAL CODE PLAN 13 4 3 2 KEYNOTES - CODE PLANS 1 CONTINUOUS AIR AND WEATHER BARRIER, TYVEK OR EQUIVALENT. SEE WALL SECTIONS AND DETAILS FOR MORE SPECIFIC LOCATIONS IN SECTION.AIR AND WEATHER BARRIER FORMS PRESSURE BOUNDARY. 2 OWNER TO PROVIDE A MAXIMUM OCCUPANT LOAD SIGN NEAR MAINENTRANCE TO READ "ROOM OCCUPANCY NOT TO EXCEED 115 PEOPLE" 3 OWNER TO PROVIDE A MAXIMUM OCCUPANT LOAD SIGN NEAR MAINENTRANCE TO READ "ROOM OCCUPANCY NOT TO EXCEED 35 PEOPLE" 4 OWNER TO PROVIDE A MAXIMUM OCCUPANT LOAD SIGN NEAR MAINENTRANCE TO READ " ROOM OCCUPANCY NOT TO EXCEED 17 PEOPLE" 5 WEATHERSTRIP EXTERIOR DOORS TO MINIMIZE AIR LEAKAGE 6 PROVIDE DOOR SEALS TO ELIMINATE SMOKE OR AIR PASSAGE. 7 LINEN CHUTE DISCHARGE DOORS MUST BE TOP-HINGED WITH FUSIBLE LINKRELEASE, FIRE/SMOKE SEALS. 8 OUTSIDE AIR INTAKE 9 EXHAUST OPENING 10 ELEVATOR SHAFT RELIEF OPENING IN ROOF 11 CONDITIONED VESTIBULE WITHIN BUILDING THERMAL ENVELOPE. 12 DOOR NOT INTENDED TO BE USED AS BUILDING ENTRANCES (C402.5.7EXCEPTION 1). 13 OWNER TO PROVIDE A MAXIMUM OCCUPANT LOAD SIGN NEAR MAINENTRANCE TO READ "ROOM OCCUPANCY NOT TO EXCEED 48 PEOPLE" 14 OWNER TO PROVIDE A MAXIMUM OCCUPANT LOAD SIGN NEAR MAINENTRANCE TO READ "ROOM OCCUPANCY NOT TO EXCEED 178 PEOPLE" 15 3" ROLLED SEMI-RECESSED FIRE EXTINGUISHER CABINET WITH 10 LBS ABCFIRE EXTINGUISHER.FIRE EXTINGUISHER. ALL FIRE EXTINGUISHERS IN PUBLICAREAS TO BE INSTALLED IN CABINETS. CABINETS TO BE INSTALLED SO THATNO OPERABLE PART IS HIGHER THAN 48" A.F.F. 16 10 LBS ABC FIRE EXTINGUISHER ON HOOK ATTACHED TO WALL 17 2.5 GAL TYPE K FIRE EXTINGUISHER ON HOOK ATTACHED TO WALL 18 2.5 GAL WATER MIST FIRE EXTINGUISHER ON HOOK ATTACHED TO WALL 19 OWNER TO PROVIDE A MAXIMUM OCCUPANT LOAD SIGN NEAR MAINENTRANCE TO READ "ROOM OCCUPANCY NOT TO EXCEED 178 PEOPLE" 20 FIRE SEPARATION DOORS TO BE ON AUTOMATIC CLOSURES ACTIVATED BYFIRE ALARM SYSTEM. 21 WALL MOUNTED SAFETY AND EVACUATION INFORMATION. 22 THIS ELEVATOR CAR SHALL BE LARGE ENOUGH TO ACCOMMODATE ANAMBULANCE STRETCHER. ELEVATOR SHALL RETURN TO FIRST FLOOR INEVENT OF POWER OUTAGE. 23 2 HR FIRE RATED LINEN CHUTE 24 STANDPIPE 25 FIRE RISER AND FLOOR CONTROLS 26 EMERGENCY SHUTOFF BUTTON FOR GAS FIRE PITS AND GAS GRILL. 27 2-WAY COMMUNICATION TO FRONT DESK FROM ELEVATOR LOBBYAREA-OF-REFUGE A-2 B A-4 A-2 A-3 A-2 A-2 S-1 A-4A-4 S-1 S-1 S-1 S-1 S-1B A-2 R-1 S-1 A-4 FIRST FLOOR OCCUPANCY SPACE NAME AREA OCC. LOAD PEOPLE ASSEMBLY A-2 EMPLOYEE ROOM 512 SF 15 NSF 35 FOOD PREP601 SF 200 GSF 4 LOBBY2,657 SF 15 NSF 178 LOBBY SUPPORTSPACES711 SF 50 GSF 15 MEETING ROOM 406 SF FIXED MAX 48 280 A-3 FITNESS801 SF 50 GSF 17 17 A-4 POOL432 SF 50 GSF 9 POOL DECK1,458 SF 15 GSF 98 POOL RESTROOM 80 SF 50 GSF 2 SPLASH PAD272 SF 50 GSF 6 115 BUSINESS B LAUNDRY LOUNGE 257 SF 200 GSF 2 OFFICES593 SF 150 GSF 4 6 RESIDENTIAL R-1 GUEST ROOMS 3,818 SF 200 GSF 20 20 STORAGE/SERVICE S-1 BOH LAUNDRY 967 SF 100 GSF 10 ELECTRICAL472 SF 300 GSF 2 LINEN STORAGE 148 SF 300 GSF 1 MEETING STORAGE 81 SF 300 GSF 1 OUTDOOR STORAGE 47 SF 300 GSF 1 POOL MEP204 SF 300 GSF 1 WATER HEATERS 361 SF 300 GSF 2 18 Grand total456 R-1 S-1 S-1 2NDFLRONLY R-1 20 21 6 6 6 7 8 8 20 10 12 11. SEE MECHANICAL FOR INFORMATION ON AIR LEAKAGE TESTINGPROCEDURES AND REQUIREMENTS. 10. COMPLY WITH IBC 2018 SECTION 703.7 REGADING MARKING ANDIDENTIFICATION OF PROTECTED SPACES, WALLS, PARTITIONS OR BARRIERS.THESE SHALL BE EFFECTIVELY AND PERMANENTLY IDENTIFIED WITH SIGNSOR STENCILING IN CONCEALED SPACES AS FOLLOWS: A. BE LOCATED WITHIN 15 FT OF THE END OF EACH WALL AND AT INTERVALSNOT EXCEEDING 30 FT MEASURED HORIZONTALLY ALONG THE WALL ORPARTITIONSB. INCLUDE LETTERING NOT LESS THAT THAN 3 IN TALL WITH A MINIMUM 3/8IN STROKE IN A CONTRASTING COLOR INCORPORATING THE SUGGESTEDWORKING "FIRE AND/OR SMOKE BARRIER - PROTECT ALL OPENINGS" OR... 9. ALL GYPSUM BOARD INDICATED IN RATED PARTITIONS TO BE 5/8" TYPE XGYPSUM BOARD. 8. ALL RATED PARTITIONS TO EXTEND TO DECK ABOVE WITH A TIGHT SEAL.SEAL ALL PENETRATIONS WITH FIRE STOPPING. 7. SEE DOOR SCHEDULE FOR DOOR FIRE RATINGS, WIDTHS AND PANICHARDWARE LOCATIONS. 6. FIRE EXTINGUISHERS, SMOKE DETECTORS & OTHER EMERGENCY DEVICESTO BE LOCATED PER LOCAL CODE - FIRE EXTINGUISHER LOCATIONS W/INTHE PUBLIC SPACE SHALL BE CONTAINED WITHIN SEMI-RECESSED CABINETS 5. DIRECTIONAL ARROWS INDICATE MEANS OF EGRESS FOR OCCUPANTS. NOTRAVEL DISTANCE EXCEEDS 250 FEET, NO COMMON PATH OF TRAVELEXCEEDS 75 FEET. NO DEAD END CORRIDOR EXCEEDS 50 FEET. 4. REFER TO FIRE PROTECTION, ELECTRICAL AND MECHANICAL DRAWINGS FORSPECIFIC INFORMATION ON FIRE PROTECTION SYSTEMS, FIRE ALARMSYSTEMS, EXIT SIGN LOCATIONS, AND ENERGY EFFICIENCY MEASURESPERTAINING TO MECHANICAL SYSTEMS. 3. ALL RECESSED LIGHTING FIXTURES SHALL BE IC RATED AND HAVE AN AIRLEAKAGE RATING NOT GREATER THAN 2 CFM PER ASTM E283 TEST. 2. SEAL AND CAULK ALL LIGHT FIXTURE HOUSINGS IN EXTERIOR WALLS ORCEILINGS PER MANUFACTURER'S INSTRUCTIONS SO AS TO ELIMINATE AIRLEAKAGE. 1. REFER TO HOMEWOOD SUITES AND HILTON STANDARDS FOR ADDITIONALINFORMATION REGARDING EXTERIOR ENVELOPE REQUIREMENTS. GENERAL NOTES- CODE 14 19 21 21 212121 21 21 21 21 TYPICAL FLOOR OCCUPANCY SPACE NAMEAREA OCC. LOAD PEOPLE RESIDENTIAL R-1 GUEST ROOMS 17,670 SF 200 GSF 89 89 STORAGE/SERVICE S-1 LINEN ROOM356 SF300 GSF 2 2 Grand total91 SECOND FLOOR OCCUPANCY SPACE NAMEAREA OCC. LOAD PEOPLE RESIDENTIAL R-1 GUEST ROOMS 17,086 SF 200 GSF 86 86 STORAGE/SERVICE S-1 ENGINEERING OFFICEAND PBX/MDF356 SF300 GSF 2 LINEN ROOM584 SF300 GSF 2 4 Grand total90 POOL280 PEOPLE 2 44" 44" FIRST FLOOR 176 PEOPLE 2 44" 44" CORR. STAIR LEVELOCCUPANTLOADREQ'DEXITS REQ'D WIDTH FIRST FLOOR EGRESS WIDTHS FIFTH FLOOR 91 PEOPLE 2 44" 44" FOURTH FLOOR 91 PEOPLE 2 44" 44" THIRD FLOOR 91 PEOPLE 2 44" 44" SECOND FLOOR 90 PEOPLE 2 44" 44" CORR. STAIR LEVELOCCUPANTLOADREQ'DEXITS REQ'D WIDTH UPPER FLOOR EGRESS WIDTHS 0'8' 16'32' SCALE: 1/16" = 1'-0" 20 66 6 1515 17 16 15 15 16 16 1818 22 22 21 21 212121 21 21 21 21 2121212121 21212121212121 21 21 21 21 21 21 21 21 21 21 23 23 24 15 15 15 15 1515 15 15 25 24 26 26 26 27 16 16 16 EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV Revision Schedule Number Description Date DDDD WWWW 5 3 3.1 6.1 2.1 D C.1 FG ML.1EC C B B 1 11 8.1 9 4 1.1 A KNP Q 2 7 8 6 10 H J L EMPLOYEEROOM 110 POOL &SPLASHPAD 101 ELECTRICAL 104 POOL MEP 103 POOLRESTROOM 102 BOHLAUNDRY 105 BOHDRYERS 105A LINENDISCHARGE& SORTING 107 LINENCHUTE 140 ELEVATORLOBBY 117 ELEV 1 111 ELEV 2 113 WATERHEATER &FIRE 108 STAIR 1 106 LAUNDRYLOUNGE 112 FITNESS 114 MEN'SRESTROOM 116 LINENSTORAGE 109 GUESTSTORAGE 118 WOMEN'SRESTROOM 115 LOBBY 121 FOOD PREP 123 PUBLICCORRIDOR 121A GUESTCORRIDOR 139 EFFICIENCY 129 EFFICIENCY 131 EFFICIENCY 133 DOUBLEQUEEN 135 KINGSTUDIOADA-M-T 138 DOUBLEQUEEN 136 EFFICIENCY 134 STAIR 2 132 KINGSTUDIO 130 OPENOFFICE 124 GM OFFICE 125VESTIBULE 122 MEETINGROOM 120 MEETINGSTORAGE 119 SALESOFFICE 126 OWNER'SOFFICE 127 ELECTRICAL 128 COURTYARDSTORAGE 141 VESTIBULE 139A PUBLICCORRIDOR 100 VESTIBULE 100A EMP RRADA 110AEMP RR 110B KINGSTUDIO 137 LANAI 137A LANAI 135A 138 - BATHTUB 133 5 3 3.1 6.1 2.1 D C.1FGML.1EC C B B 1 8.1 9 4 1.1 A KNP Q 2 7 8 6 10 HJ L KING1-BEDROOMADA-M-T x01 CONNECTINGCORRIDOR x00 KING1-BEDROOM x02 KINGSTUDIO x04 EFFICIENCYENLARGED x03 EFFICIENCY x05 EFFICIENCY x07 LINENS &HOUSEKEEPING x09 EFFICIENCY x08 DOUBLEQUEEN x10 STAIR 1 x06 DOUBLEQUEENENLARGED x12 KINGSTUDIO x14KINGSTUDIO x16 KINGSTUDIO x18 KINGSTUDIO x20 ELEV 1 111 ELEV 2 113 ELEVATORLOBBY x17 KINGSTUDIO x19 KINGSTUDIO x21 KINGSTUDIO x23 KINGSTUDIO x25 EFFICIENCY x27 EFFICIENCY x29 EFFICIENCY x31 EFFICIENCY x33DOUBLEQUEEN x35 KINGSTUDIO x37 KINGSTUDIOADA-M-RI x38 DOUBLEQUEEN x36 EFFICIENCY x34 STAIR 2 x32 KINGSTUDIO x30 EFFICIENCY x28 KINGSTUDIO x26 DOUBLEQUEEN x24 DOUBLEQUEEN x22 GUESTCORRIDOR x15 ELECTRICAL X15A BALCONY X35A BALCONY X37A BALCONY X23A BALCONY X25A BALCONY X01ABALCONY X02A BALCONY X19A BALCONY X21A FLOOR 10' - 0" FLOOR 216' - 0" FLOOR 327' - 0" FLOOR 438' - 0" FLOOR 549' - 0" MAIN ROOF61' - 2" LOW PARAPET63' - 10" MIDDLE PARAPET65' - 10" SITE-0' - 6" 9786 10 EFFICIENCY 131 EFFICIENCY 231 EFFICIENCY 331 EFFICIENCY 431 EFFICIENCY 531 ROOFACCESS 539STAIR 2 532 STAIR 2 432 STAIR 2 332 STAIR 2 232 STAIR 2 132 11' - 0"11' - 0"11' - 0"16' - 0"12' - 2"1/2 HOUR FIRE RATED WALL 1 HOUR FIRE RATED WALL 2 HOUR FIRE RATED WALL 1/2 HOUR FIRE RATED CORRIDOR 1 HOUR SMOKE BARRIER AT ELEVATOR LOBBY 2 HOUR FIRE RATED SHAFT THERMAL ENVELOPE BOUNDARY ACCESSIBLE ROOM - MOBILITY ACCESSIBLE ROOM - COMMUNICATION FEATURE CODE LEGEND 1 9 10 11 11 11 1/16" = 1'-0"11ST FLOOR ENVELOPE & ACCESSIBILITY PLAN 1/16" = 1'-0"2FLOORS 2-5 TYPICAL ENVELOPE & ACCESSIBILITY PLAN 1/16" = 1'-0"3 THERMAL ENVELOPE CROSS SECTION 0'4' 8'16' SCALE: 1/8" = 1'-0" 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216BUILDING ENVELOPE &ACCESIBILITY PLANS A-002 FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 5 5 5 5 5 5 5 5 5 1 1 6 66 6 6 6 9 8 8 KEYNOTES - CODE PLANS 1 CONTINUOUS AIR AND WEATHER BARRIER, TYVEK OR EQUIVALENT. SEE WALL SECTIONS AND DETAILS FOR MORE SPECIFIC LOCATIONS IN SECTION.AIR AND WEATHER BARRIER FORMS PRESSURE BOUNDARY. 2 OWNER TO PROVIDE A MAXIMUM OCCUPANT LOAD SIGN NEAR MAINENTRANCE TO READ "ROOM OCCUPANCY NOT TO EXCEED 115 PEOPLE" 3 OWNER TO PROVIDE A MAXIMUM OCCUPANT LOAD SIGN NEAR MAINENTRANCE TO READ "ROOM OCCUPANCY NOT TO EXCEED 35 PEOPLE" 4 OWNER TO PROVIDE A MAXIMUM OCCUPANT LOAD SIGN NEAR MAINENTRANCE TO READ " ROOM OCCUPANCY NOT TO EXCEED 17 PEOPLE" 5 WEATHERSTRIP EXTERIOR DOORS TO MINIMIZE AIR LEAKAGE 6 PROVIDE DOOR SEALS TO ELIMINATE SMOKE OR AIR PASSAGE. 7 LINEN CHUTE DISCHARGE DOORS MUST BE TOP-HINGED WITH FUSIBLE LINKRELEASE, FIRE/SMOKE SEALS. 8 OUTSIDE AIR INTAKE 9 EXHAUST OPENING 10 ELEVATOR SHAFT RELIEF OPENING IN ROOF 11 CONDITIONED VESTIBULE WITHIN BUILDING THERMAL ENVELOPE. 12 DOOR NOT INTENDED TO BE USED AS BUILDING ENTRANCES (C402.5.7EXCEPTION 1). 13 OWNER TO PROVIDE A MAXIMUM OCCUPANT LOAD SIGN NEAR MAINENTRANCE TO READ "ROOM OCCUPANCY NOT TO EXCEED 48 PEOPLE" 14 OWNER TO PROVIDE A MAXIMUM OCCUPANT LOAD SIGN NEAR MAINENTRANCE TO READ "ROOM OCCUPANCY NOT TO EXCEED 178 PEOPLE" 15 3" ROLLED SEMI-RECESSED FIRE EXTINGUISHER CABINET WITH 10 LBS ABCFIRE EXTINGUISHER.FIRE EXTINGUISHER. ALL FIRE EXTINGUISHERS IN PUBLICAREAS TO BE INSTALLED IN CABINETS. CABINETS TO BE INSTALLED SO THATNO OPERABLE PART IS HIGHER THAN 48" A.F.F. 16 10 LBS ABC FIRE EXTINGUISHER ON HOOK ATTACHED TO WALL 17 2.5 GAL TYPE K FIRE EXTINGUISHER ON HOOK ATTACHED TO WALL 18 2.5 GAL WATER MIST FIRE EXTINGUISHER ON HOOK ATTACHED TO WALL 19 OWNER TO PROVIDE A MAXIMUM OCCUPANT LOAD SIGN NEAR MAINENTRANCE TO READ "ROOM OCCUPANCY NOT TO EXCEED 178 PEOPLE" 20 FIRE SEPARATION DOORS TO BE ON AUTOMATIC CLOSURES ACTIVATED BYFIRE ALARM SYSTEM. 21 WALL MOUNTED SAFETY AND EVACUATION INFORMATION. 22 THIS ELEVATOR CAR SHALL BE LARGE ENOUGH TO ACCOMMODATE ANAMBULANCE STRETCHER. ELEVATOR SHALL RETURN TO FIRST FLOOR INEVENT OF POWER OUTAGE. 23 2 HR FIRE RATED LINEN CHUTE 24 STANDPIPE 25 FIRE RISER AND FLOOR CONTROLS 26 EMERGENCY SHUTOFF BUTTON FOR GAS FIRE PITS AND GAS GRILL. 27 2-WAY COMMUNICATION TO FRONT DESK FROM ELEVATOR LOBBYAREA-OF-REFUGE 238 - BATHTUB338 - ROLL-IN SHOWER 301 - BATHTUB 503 - BATHTUB403 - ROLL-IN SHOWER 512 - BATHTUB 238 303 519325435508 404 202 530428 322 11. SEE MECHANICAL FOR INFORMATION ON AIR LEAKAGE TESTINGPROCEDURES AND REQUIREMENTS. 10. COMPLY WITH IBC 2018 SECTION 703.7 REGADING MARKING ANDIDENTIFICATION OF PROTECTED SPACES, WALLS, PARTITIONS OR BARRIERS.THESE SHALL BE EFFECTIVELY AND PERMANENTLY IDENTIFIED WITH SIGNSOR STENCILING IN CONCEALED SPACES AS FOLLOWS: A. BE LOCATED WITHIN 15 FT OF THE END OF EACH WALL AND AT INTERVALSNOT EXCEEDING 30 FT MEASURED HORIZONTALLY ALONG THE WALL ORPARTITIONSB. INCLUDE LETTERING NOT LESS THAT THAN 3 IN TALL WITH A MINIMUM 3/8IN STROKE IN A CONTRASTING COLOR INCORPORATING THE SUGGESTEDWORKING "FIRE AND/OR SMOKE BARRIER - PROTECT ALL OPENINGS" OR... 9. ALL GYPSUM BOARD INDICATED IN RATED PARTITIONS TO BE 5/8" TYPE XGYPSUM BOARD. 8. ALL RATED PARTITIONS TO EXTEND TO DECK ABOVE WITH A TIGHT SEAL.SEAL ALL PENETRATIONS WITH FIRE STOPPING. 7. SEE DOOR SCHEDULE FOR DOOR FIRE RATINGS, WIDTHS AND PANICHARDWARE LOCATIONS. 6. FIRE EXTINGUISHERS, SMOKE DETECTORS & OTHER EMERGENCY DEVICESTO BE LOCATED PER LOCAL CODE - FIRE EXTINGUISHER LOCATIONS W/INTHE PUBLIC SPACE SHALL BE CONTAINED WITHIN SEMI-RECESSED CABINETS 5. DIRECTIONAL ARROWS INDICATE MEANS OF EGRESS FOR OCCUPANTS. NOTRAVEL DISTANCE EXCEEDS 250 FEET, NO COMMON PATH OF TRAVELEXCEEDS 75 FEET. NO DEAD END CORRIDOR EXCEEDS 50 FEET. 4. REFER TO FIRE PROTECTION, ELECTRICAL AND MECHANICAL DRAWINGS FORSPECIFIC INFORMATION ON FIRE PROTECTION SYSTEMS, FIRE ALARMSYSTEMS, EXIT SIGN LOCATIONS, AND ENERGY EFFICIENCY MEASURESPERTAINING TO MECHANICAL SYSTEMS. 3. ALL RECESSED LIGHTING FIXTURES SHALL BE IC RATED AND HAVE AN AIRLEAKAGE RATING NOT GREATER THAN 2 CFM PER ASTM E283 TEST. 2. SEAL AND CAULK ALL LIGHT FIXTURE HOUSINGS IN EXTERIOR WALLS ORCEILINGS PER MANUFACTURER'S INSTRUCTIONS SO AS TO ELIMINATE AIRLEAKAGE. 1. REFER TO HOMEWOOD SUITES AND HILTON STANDARDS FOR ADDITIONALINFORMATION REGARDING EXTERIOR ENVELOPE REQUIREMENTS. GENERAL NOTES- CODE EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV Revision Schedule Number Description Date D F 1 11 EAST CARLISLE A V E N U EEAST M IRABEAU PARKWAY A-402 1 A-4011 N67° 3 0 ' 1 7 " W 399.9 6 ' N89° 44'32" W 55.93' R: 4 9 2 . 4 7 ' L: 14 4 . 7 4 'R: 726.41'L: 487.82'N22° 44'41" E345.57'S82° 44'03" E 160.47' L: 148.59' R: 550.00' 3.30' 155.07' 105.40'R: 30.00'L: 44.98'6' - 9 1/2"CENT E N N I A L T R A I L SPOK A N E R I V E R 145' - 1"9A Q 6 H A-4031 A-407 1MIN. 20' - 0"A-4012 HOMEWOOD SUITES BY HILTON132 KEYS 10' - 0" 10' - 0"10' - 0"18' - 0"36' - 0"8' - 0" 8' - 0"5' - 0" 8' - 0" 9' - 0"9' - 0"9' - 0"18' - 0"10' - 0"1 2 3 4 5 6 7 8 9 10 11 12 13 A14 15 16 17 18 C19 C20 C21 C22 C23 C24 C25 C26 C27 C28 C29 C30 C31 C32 C33 C34 C35 C36 C37 C38 C39 C40 C41 C42 43 44 45 46 48 47 49 50 51 52 53 54 55 56 57 C58C59C60C61C62C63C64C65C66 6768697071727374757677 86 R78 87 79 R80 R81 R82 R83 84 85 88 89 90 91 92 93 989694 999795 100 101 102 103 R104 R105 R106 R107 R108 R109 110112114116118119121 111113115117120122123124 125126128130 127129 132134136138140142 131133135137139141 A143A144A145A146A147 18' - 0"18' - 0"18' - 0"9' - 0" 9' - 0"18' - 0"30' - 0" 30 ' - 0 "36' - 0"29' - 3 1/4"R 30' - 0"R 30' - 0" R 4 8 ' - 0 " R 48' - 0" R 15' - 0"R 1 5 ' - 0 " 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216OVERALL SITE PLAN A-010 FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 1" = 30'-0"1ARCHITECTURAL SITE PLAN PARKING NOTES COMPACT STALLS: 33 STALLS PROVIDEDSIZE: 8'-0" X 18'-0" PER SPOKANE CODE (BRAND STANDARDS DO NOT SPECIFY COMPACT SIZE)MAX 25% STALLS ALLOWED TO BE COMPACT PER BRAND STANDARDS (147 * 0.25 = 37 STALLS)STALLS DESIGNATED TO CONTIGUOUS AREAS PER SPOKANE CODE STANDARD STALLS: 108 STALLS PROVIDEDSIZE 9'-0" X 18'-0" PER BRAND STANDARDS ADA STALLS: 6 STALLS PROVIDED6 REQUIRED PER SPOKANE CODE UP TO 150 STALLSADA STANDARD: 5 STALLS PROVIDED [SIZE: 8'-0" X 18'-0" (ADAAG) + 5'-0" ACCESS AISLE (ADAAG)]ADA VAN: 1 STALL PROVIDED [SIZE: 8'-0" X 18''-0" + 8'-0" ACCESS AISLE (ADAAG)] TOTAL STALLS: 147 STALLS PROVIDED SITE NOTES BIKE RACKS: 4 SETS OF 2 PROVIDED3 SETS OF BIKE STORAGE FOR 2 BIKES EACH FOR 100-500 SPACES PER SPOKANE CODE FIRE LANES: (INFORMATION PROVIDED BY AHJ FIRE REVIEWER)NO FIRE LANE REQUIRED ON NORTH SIDE OF BUILDING BECAUSE BUILDING WILL BE FULLY SPRINKLERED PER NFPA 13.FIRE LANES MUST BE 26' WIDE WITH FULL CLEAR HEIGHT FOR AERIAL ACCESS AROUND BUILDING. ELECTRIC VEHICLE READY STALLS: 16 EV-READY STALLS PROVIDED (INCLUDING 1 ADA VAN ACCESSIBLE)10% STALLS REQUIRED TO BE EV-READY PER WAC CODE (147 * 0.10 = 15 STALLS, INCLUDING 1 ADA STALL) ELECTRIC VEHICLE CHARGING STATIONS: 2 STALLS WITH EV STATIONS PROVIDED (INCLUDING 1 ADA)MINIMUM 2 STALLS REQUIRED TO HAVE EV STATIONS INSTALLED PER HILTON BRAND STANDARDS 0'15' 30'60' SCALE: 1" = 30'-0" KEYNOTES - SITE PLAN 1 PAD-MOUNTED TRANSFORMER. SEE ELECTRICAL. PROVIDE DENSE LANDSCAPE SCREENING AND/OR FENCING ATTRANSFORMER PAD PER LOCAL UTILITY COMPANY STANDARDS. 2 ACCESSIBLE PASSENGER DROP OFF AREA W/ ADJACENT CLEAR ACCESS AISLE. DROP OFF AND ACCESS AISLESHALL BE AT THE SAME LEVEL AND SHALL HAVE A SLOPE NOT TO EXCEED 1:48 (1:64 RECOMMENDED). DRIVE AISLESSHALL RAMP UP TO LEVEL OF WALK AT DROP-OFF AREA. 3 OUTDOOR KITCHEN 4 EMERGENCY GENERATOR. SEE ELECTRICAL. PROVIDE DENSE LANDSCAPE SCREENING AT GENERATORENCLOSURE. 5 LINE OF PORTE COCHERE AVOVE, ALIGN WITH EDGE OF CONCRETE APRON 6 FLAGPOLE, 25' TALL WITH UPLIGHT IN GROUND. FLAGS TO BE DETERMINED BY OWNER (EITHER UNITED STATESONLY, OR UNITED STATES, WASHINGTON STATE AND HOMEWOOD SUITES). 7 ILLUMINATED HOMEWOOD SUITES MONUMENT SIGN 8 CONTINUOUS 6" CONCRETE CURB, TYP. 9 EXTERIOR STORAGE SHED 10 DUMPSTER ENCLOSURE FOR TRASH AND RECYCLING WITH GATE AND LOCKING HARDWARE 11 4' HIGH ORNAMENTAL IRON FENCE 12 3' HIGH ORNAMENTAL IRON FENCE ON RETAINING WALL EXTENDING 1' ABOVE GRADE (MIN. 3' - 6" ABOVE GRADE ATALL LOCATIONS WITH A DROP GREATER THAN 30"). 13 ILLUMINATED HOMEWOOD SUITES DRIVEWAY SIGN 14 EV READY STALLS. PROVIDE CONCRETE WHEEL STOP. 15 EV CHARGING STALLS. EV CHARGING STATIONS MUST HAVE BOTH UNIVERSAL AND PROPRIETARY CHARGINGCAPABILITITES AND AT LEAST LEVEL 2 CHARGING (AT MINIMUM). PROVIDE CONCRETE WHEEL STOP. SIGNAGE MUSTBE PROVIDED AT EACH STALL STATING, "ELECTRIC VEHICLE PARKING ONLY WHILE CHARGING" 16 COMPACT SPACES. 8' WIDE BY 18' LONG. 17 ACCESSIBLE PARKING SPACE - 8' WIDE BY 18' LONG AND 5' WIDE AISLE FOR ACCESSIBLE PARKING SPACES.PROVIDE SIGNAGE AS REQUIRED. PROVIDE CONCRETE WHEEL STOP AT ACCESSIBLE SPACES. 18 ACCESSIBLE PARKING SPACE - VAN ACCESSIBLE AND EV CHARGING STATION. 8' WIDE BY 20' LONG AND 8' WIDEAISLE FOR VAN ACCESSIBLE PARKING STALL. PROVIDE SIGNAGE FOR ACCESSIBLE PARKING STALL AS REQUIRED.PROVIDE SIGNAGE INDICATING VAN ACCESSIBLE STALL. PROVIDE SIGN THAT READS, "ELECTRIC VEHICLE PARKINGPREFERRED" BELOW ACCESSIBILITY SIGNS. PROVIDE CONCRETE WHEEL STOP. ANY VEHICLE WITH AN ACCESSIBLEPARKING PERMIT MUST BE ALLOWED TO PARK IN THIS SPACE. 19 SEMI-ENCLOSED SMOKING SHELTER GREATER THAN 25' FROM WINDOWS, DOORS OR AIR INTAKE VENTS. PROVIDEBENCH AT ADA ACCESSIBLE HEIGHT, ASH RECEPTACLE AND TRASH CAN. SCREEN WITH LANDSCAPING WHEREPOSSIBLE. 20 ACCESSIBLE CURB RAMP TO MEET ALL ACCESSIBILITY REQUIREMENTS. MAXIMUM SLOPE OF RUN 1:12, MAXIMUMCROSS SLOPE OF 2%, PROVIDE DETECTABLE WARNING EXTENDING MIN. 2' FROM BACK OF CURB. 21 12' X 30' LOADING ZONE. PROVIDE SIGNAGE AS REQUIRED. 22 26' WIDE FIRE LANE. NO PARKING. PROVIDE SIGNAGE AS REQUIRED BY AHJ. 23 KNOX BOX 24 BOLLARDS AND CHAIN. KEY TO CHAIN PADLOCK IN KNOX BOX. 25 ACCESSIBLE ROUTE. MARK WHERE ROUTE CROSSES VEHICULAR TRAFFIC. 26 ASPHALT PAVING. PROVIDE POSITIVE DRAINAGE AWAY FROM BUILDING. 27 RV, BUS OR OVERSIZED VEHICLE PARKING WHEN REQUIRED. 9'WX36' COMBINED. 28 PET EXERCISE AND RELIEF AREA. AREA MUST BE CLEARLY DESIGNATED WITH SIGNAGE. 29 STAMPED, COLORED CONCRETE APRON AND COURTYARD 30 CANOPY ABOVE 31 40'x100' WEDDING AREA, GREATER THAN 20' FROM BUILDING WALLS. OWNER TO SECURE EVENT PERMIT WITHSPOKANE VALLEY FIRE DEPARTMENT PRIOR TO EVENTS. 32 MAINTAIN APPROPRIATE SIGHT LINES AT DRIVEWAY ENTRANCES AND EXITS. 33 ALL EQUIPMENT (INCLUDING DRYER VENTS) MUST BE SCREENED WITH LANDSCAPING OR OTHER MEANS. 34 ACCESSIBLE PARALLEL CURB RAMP TO MEET ALL ACCESSIBILITY REQUIREMENTS. MAXIMUM SLOPE OF RUN 1:12,MAXIMUM CROSS SLOPE OF 2%, PROVIDE DETECTABLE WARNING EXTENDING MIN. 2' FROM BACK OF CURB. SEECIVIL FOR ELEVATIONS. 35 GREASE TRAP. SEE PLUMBING 36 DRAINAGE POND 37 EXISTING FLUSH UTILITY ACCESS BOX 38 PROPERTY LINE 39 LANDSCAPE AREA. SEE LANDSCAPE PLANS, TYP. 40 SITE LIGHT- SEE ELECTRICAL 41 PET AREA SITE LIGHT- SEE ELECTRICAL 42 HEADLIGHT SCREENING VIA EVERGREEN LANDSCAPING ALONG ENTIRE LENGTH OF PARKING LOT FACINGMIRABEAU PARKWAY AND EAST CARLISLE AVENUE WHERE CARS ARE PARKING FACING STREET. SEE LANDSCAPE. 43 RV, BUS OR OVERSIZED VEHICLE PARKING WHEN REQUIRED. 10'WX36' COMBINED. 44 RESERVED PARKING FOR DIAMOND MEMBERS. SEE HILTON SIGNAGE GUIDE FOR SIGN REQUIREMENTS. 45 UTILITY EASEMENT 46 5' WIDE SIDEWALK. SEE CIVIL FOR DETAILS AND ELEVATIONS. 47 6' WIDE SIDEWALK. SEE CIVIL FOR DETAILS AND ELEVATIONS. 48 CONCRETE WHEEL STOPS 49 EV CHARGING STATION AT ACCESSIBLE/STANDARD SPACE COMBINATION. SCREEN AND ANY CONTROLS MUST FACETHE SIDEWALK. ALL CONTROLS MUST BE BELOW 48" A.F.F. 50 EXISTING UTILITY CONNECTION 51 EXISTING FIRE HYDRANT 52 EXISTING TRANSFORMER 1 4 6 7 8 9 10 28 13 15 13 21 22 34 22 22 22 22 23 24 25 25 26 434343 19 3 30 30 30 31 272727 32 32 33 33 25 25 11 12 12 SITE NOTES 36 36 18 20 19 8. CATCH BASINS ARE TO BE PLACED SO AS NOT TO INTERFERE WITH DESIGNATED ACCESSIBLE ROUTES. 7. 10% OF NON-PAVED, NON-COVERED AREA OF PROJECT SITE TO BE LANDSCAPED. 6. INSTALL ACCENT PLANTINGS OF ANNUALS AND PERENNIALS AT MAIN ENTRANCE, BUILDING ENTRY, AND SIGNAGEAREAS, AND BACKYARD. 5. SOD ALL AREAS NOT WITHIN PLANTING BEDS. 4. IRRIGATE ALL LANDSCAPED AREAS WITH AUTOMATIC UNDERGROUND SPRINKLER SYSTEM. 3. BUILDING UPLIGHTING SHALL NOT BE OBSTRUCTED BY LANDSCAPE PLANTINGS. 2. REFER TO HILTON SIGNAGE STANDARDS, BRAND STANDARDS AND HILTON marKIT FOR ADDITIONAL INFORMATIONAND PRECISE SIGNAGE REQUIREMENTS. ELECTRICAL FOR BUILDING SIGNAGE AND MONUMENT SIGNAGE SHALLBE PROVIDED AND CONNECTED BY THE CONTRACTOR. 1. COORDINATE LIGHTING LOCATIONS WITH LANDSCAPE PLANTINGS GENERAL NOTES- SITE 38 40 48TYP. 39 40 40 40 40 39 39 40 40 40 40 41 41 42 42 4444444444 14 14 34 42 45 45 3939 46 46 46 47 47 46 3939 39 39 39 39 39 39 39 39 39 39 40 39 39 39 40 40 48TYP. 2 2 48TYP.49 50 5052 37 51 14 14 14 14 14 14 14 14 14 14 14 14 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 161616161616161616 35 3940 40 1717171717 2 39 46 EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV REVISION SCHEDULE # DESCRIPTION DATE 2 ADDENDUM 2 6/21/2024 DN DDDD WWWW UP UP A-2012 A-202 A-202 A-201 1 2 1 MEN'SRESTROOM 116 WOMEN'SRESTROOM 115MEETING STORAGE 119 MEETINGROOM 120 GUEST STORAGE 118FITNESS 114 VESTIBULE 122 COURTYARDSTORAGE 141 GUEST CORRIDOR 139 LOBBY 121 LAUNDRYLOUNGE 112 EMPLOYEEROOM 110 WATER HEATER & FIRE 108 EMP RR ADA 110AEMP RR 110B POOL &SPLASH PAD 101 POOLRESTROOM 102 ELECTRICAL 104 STAIR 1 106 PUBLIC CORRIDOR 100 BOH LAUNDRY 105 LINENSTORAGE 109 HOUSEKEEPINGOFFICE 109A LINENDISCHARGE &SORTING 107 POOL MEP 103 5 3 3.1 6.1 2.1 D C.1 FG ML.1E 1 A-301 FOOD PREP 123 A-420 4 A-4144 C C B B 1 ELEVATORLOBBY117ELEV 2 113 ELEV 1 111 LINEN CHUTE 140 STAIR 2 132 ELECTRICAL 139B KING STUDIOADA-M-T 138 LANAI 135A LANAI 137A 2 A-302 3 A-302 11165' - 8 1/2"A-1221 A-121 1 PUBLICCORRIDOR 121A VESTIBULE 139A VESTIBULE 100A ELECTRICAL 128 OWNER'SOFFICE 127 SALES OFFICE 126 GM OFFICE 125 OPEN OFFICE 124 BOH DRYERS 105A 1 A-302 8.1 9 4 1.1 A A K N P Q 2 ICE/WATER 118A 7 8 6 10 H J 2 A-301 L EFFICIENCY 129 KING STUDIO 130 EFFICIENCY 131 EFFICIENCY 134 EFFICIENCY 133 DOUBLE QUEEN 136 DOUBLE QUEEN 135 KING STUDIO 137 249' - 11"60' - 3 1/2"65' - 1 1/2"184' - 9 1/2" ADA MOBILITY ROOM ADA COMMUNICATION FEATURES ROOM ADA SYMBOL LEGEND 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216OVERALL 1ST FLOORPLAN A-101 FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 3/32" = 1'-0"11ST FLOOR PLAN 0'6' 12'24' SCALE: 3/32" = 1'-0" 5. SEE STRUCTURAL TO VERIFY LOCATIONS OF ALL SHEAR WALLS. SEE ELEVATIONS TO VERIFY EXTERIOR FINISHMATERIAL AND COLOR. 4. PROVIDE AN ACCESSIBLE ROUTE AND COMPLIANT WHEELCHAIR LOCATIONS IN EACH OF THE PUBLIC SPACESPROVIDED FOR GUEST USE. 3. BOTH VISUAL AND NOTIFICATION DEVICES SHALL BE PROVIDED IN PUBLIC AND COMMON AREAS. THE SYSTEMMUST BE DESIGNED TO BE ABLE TO BE INTEGRATED INTO EMPLOYEE WORK SPACES AND MUST COMPLY WITHNFPA 72 AND STATE, LOCAL AND FEDERAL REGULATIONS. DEVICES MUST BE LOCATED SO THE LIGHT IS VISIBLE INEACH REQUIRED SPACE. 2. ALL WALLS IN BATH SHALL BE MOISTURE RESISTANT GYPSUM BOARD. BATH CEILING SHALL BE EXTERIORGYPSUM BOARD. 1. REFER TO HOMEWOOD STANDARDS FOR FLOORING REQUIREMENTS IN EACH AREA. GENERAL NOTES- FLOOR PLANS EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV Revision Schedule Number Description Date W/DW/DDN UP DN UP A-2012 A-202 A-202 A-201 1 2 1 5 3 3.1 6.1 2.1 D C.1 F G ML.1 ENGINEERINGOFFICE &STORAGE 207 E 1 A-301 PBX/MDF 207A A-4151 A-4201 A-420 2 A-414 1 A-4111A-4142 A-4221 A-4191A-417 1 C C B B 1 KING STUDIO 237 KING STUDIOADA-M-T 238DOUBLEQUEEN 236 DOUBLEQUEEN 235 EFFICIENCY 233 KING1-BEDROOM 202 KING 1-BEDROOMENLARGED 201 DOUBLEQUEEN 210 DOUBLEQUEEN ENLARGED 212 KING STUDIO 214 PANELS 209A ELEVATORLOBBY217EFFICIENCYENLARGED 203 CONNECTINGCORRIDOR 200 EFFICIENCY 229EFFICIENCY 227 EFFICIENCY 208 EFFICIENCY 205 KING STUDIO 220 KING STUDIO 218 KING STUDIO 216 KING STUDIO 226 KING STUDIO 219 KING STUDIO 221 KING STUDIO 223 KING STUDIO 225 DOUBLEQUEEN 224 DOUBLEQUEEN 222 GUESTCORRIDOR 215 EFFICIENCY 228 EFFICIENCY 231 EFFICIENCY 234 KING STUDIO 230 ELEV 2 113 ELEV 1 111 LINEN CHUTE 140 STAIR 1 206 STAIR 2 232 BALCONY 201ABALCONY 202A BALCONY 218A BALCONY 221A BALCONY 223A BALCONY 225A BALCONY 235A BALCONY 237A 2 A-302 3 A-302 11165' - 8 1/2"A-1241 A-1231 LINENS &HOUSEKEEPING 209 IDF 209B DAC 209C 1 A-302 8.1 9 4 1.1 A K N P Q 2 3 A-505 7 8 6 10 H J 2 A-301 1 A-505 L EQEQ KING STUDIO 204 ELECTRICAL 215A P3.3 P3.1 P3.2 P3.2 P3.3 P4.2 P1.1 P3.2 P3.1 P3.1 XS1 XE1/2 P9.1 XE1/2 XE3 XE1/2 XD2 XE1/2 XD2 XS1 XE1/2 P5.1 P3.2 P3.2 P3.2 P3.2 P3.1 P3.1 P3.2 P3.1P3.2 XE1/2 XE1/2 XE1/2 XE1/2 XE1/2 XE3P3.1 XE1/2 P3.2P4.1P4.3P3.1P3.2P3.2P3.2P3.2P3.2P3.1P3.2P3.1 XE1/2XE3 XE3 XS1XE1/2XS1 P3.1 P5.1P3.2 XE1/2 XE1/2 XE1/2 XE1/2 ADA MOBILITY ROOM ADA COMMUNICATION FEATURES ROOM ADA SYMBOL LEGEND 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216OVERALL 2ND FLOORPLAN A-102 FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 3/32" = 1'-0"12ND FLOOR PLAN 0'6' 12'24' SCALE: 3/32" = 1'-0" 5. SEE STRUCTURAL TO VERIFY LOCATIONS OF ALL SHEAR WALLS. SEE ELEVATIONS TO VERIFY EXTERIOR FINISHMATERIAL AND COLOR. 4. PROVIDE AN ACCESSIBLE ROUTE AND COMPLIANT WHEELCHAIR LOCATIONS IN EACH OF THE PUBLIC SPACESPROVIDED FOR GUEST USE. 3. BOTH VISUAL AND NOTIFICATION DEVICES SHALL BE PROVIDED IN PUBLIC AND COMMON AREAS. THE SYSTEMMUST BE DESIGNED TO BE ABLE TO BE INTEGRATED INTO EMPLOYEE WORK SPACES AND MUST COMPLY WITHNFPA 72 AND STATE, LOCAL AND FEDERAL REGULATIONS. DEVICES MUST BE LOCATED SO THE LIGHT IS VISIBLE INEACH REQUIRED SPACE. 2. ALL WALLS IN BATH SHALL BE MOISTURE RESISTANT GYPSUM BOARD. BATH CEILING SHALL BE EXTERIORGYPSUM BOARD. 1. REFER TO HOMEWOOD STANDARDS FOR FLOORING REQUIREMENTS IN EACH AREA. GENERAL NOTES- FLOOR PLANS EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV Revision Schedule Number Description Date W/DDN UPWD DN UP A-2012 A-202 A-202 A-201 1 2 1 5 3 3.1 6.1 2.1 D C.1 FG ML.1E 1 A-301 A-418 1 A-413 1 C C B B 1 KING STUDIO ADA-M-RI 338 KING1-BEDROOM 302 KING1-BEDROOM ADA-M-T 301 DOUBLE QUEEN 310 DOUBLEQUEENENLARGED 312 KING STUDIO 314 EFFICIENCY 307 PANELS 309A ELEVATORLOBBY317LINENS & HOUSEKEEPING 309 EFFICIENCYENLARGED 303 CONNECTINGCORRIDOR 300 EFFICIENCY 308 EFFICIENCY 305 GUESTCORRIDOR 315 ELEV 2 113 ELEV 1 111 LINEN CHUTE 140 BALCONY 301ABALCONY 302A BALCONY 319A BALCONY 321A BALCONY 323A BALCONY 325A BALCONY 335A BALCONY 337A STAIR 1 306 STAIR 2 332 IDF 309B ELECTRICAL 315A 2 A-302 3 A-302 DAC 309C 1 A-302 8.1 9 4 1.1 A A K N P Q 2 7 8 6 10 H J 2 A-301 L KING STUDIO 320 KING STUDIO 319 KING STUDIO 321 DOUBLE QUEEN 322 KING STUDIO 323 DOUBLE QUEEN 324 KING STUDIO 326 KING STUDIO 325 EFFICIENCY 327 EFFICIENCY 328 EFFICIENCY 329 KING STUDIO 330 EFFICIENCY 331 EFFICIENCY 333 EFFICIENCY 334 DOUBLEQUEEN 336 DOUBLEQUEEN 335 KING STUDIO 337 KING STUDIO 318 KING STUDIO 316 KING STUDIO 304 P3.3 P3.1 P3.1 P3.2 P3.3 P4.2 P4.2 P3.2 P3.1 P3.1 XE1/2 XE1/2 XE1/2 XE1/2 XE1/2 XE1/2 XE1/2 XE1/2 XE1/2 XD2 XE1/2 XD2 XE1/2 XE1/2 P5.1 P3.2P3.2 P3.2 P3.2 P3.1 P3.1 P3.2 P3.1P3.2 XE1/2 XE1/2 XE1/2 XE1/2 XE1/2 XE1/2P3.1 XE1/2 P3.2P4.1P4.3P3.1P3.2P3.2P3.2P3.2P3.2P3.1P3.2P3.1 XE1/2XE1/2 XE1/2 XE1/2XW1XE1/2XE1/2 P3.1 P5.1P3.2 6' - 0"19' - 7 1/4" 4' - 7 1/2"6' - 1 1/4" 8' - 8 3/4" 15' - 2 3/4" 3' - 11 1/4" 15' - 0 1/2" 9' - 3"19' - 2 3/4"25' - 8 3/4"133' - 6"30' - 6 3/4"5' - 10 1/4"28' - 8 1/2" 65' - 1 1/2"18' - 11 3/4"15' - 0 3/4"15' - 7"27' - 9 1/4"77' - 5"6' - 0"24' - 2 3/4"6' - 1 1/4"23' - 11 3/4"60' - 3 1/2"30' - 6 3/4"5' - 10 1/4" 19' - 6 1/2"19' - 1"19' - 0 3/4"19' - 1"19' - 0 3/4"19' - 0 3/4"14' - 11"19' - 1 1/2"10' - 9" 14' - 11 1/4"19' - 1 1/2"19' - 9 1/4" 249' - 11" ADA MOBILITY ROOM ADA COMMUNICATION FEATURES ROOM ADA SYMBOL LEGEND 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216OVERALL 3RD FLOORPLAN A-103 FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 3/32" = 1'-0"13RD FLOOR PLAN 0'6' 12'24' SCALE: 3/32" = 1'-0" 5. SEE STRUCTURAL TO VERIFY LOCATIONS OF ALL SHEAR WALLS. SEE ELEVATIONS TO VERIFY EXTERIOR FINISHMATERIAL AND COLOR. 4. PROVIDE AN ACCESSIBLE ROUTE AND COMPLIANT WHEELCHAIR LOCATIONS IN EACH OF THE PUBLIC SPACESPROVIDED FOR GUEST USE. 3. BOTH VISUAL AND NOTIFICATION DEVICES SHALL BE PROVIDED IN PUBLIC AND COMMON AREAS. THE SYSTEMMUST BE DESIGNED TO BE ABLE TO BE INTEGRATED INTO EMPLOYEE WORK SPACES AND MUST COMPLY WITHNFPA 72 AND STATE, LOCAL AND FEDERAL REGULATIONS. DEVICES MUST BE LOCATED SO THE LIGHT IS VISIBLE INEACH REQUIRED SPACE. 2. ALL WALLS IN BATH SHALL BE MOISTURE RESISTANT GYPSUM BOARD. BATH CEILING SHALL BE EXTERIORGYPSUM BOARD. 1. REFER TO HOMEWOOD STANDARDS FOR FLOORING REQUIREMENTS IN EACH AREA. GENERAL NOTES- FLOOR PLANS EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV Revision Schedule Number Description Date W/DW/DDN UP DN UP A-2012 A-202 A-201 1 2 5 3 3.1 6.1 2.1 D C.1 FG ML.1E 1 A-301 C C B B 1 KING STUDIOENLARGED 438 KING1-BEDROOM 402 KING1-BEDROOMENLARGED 401 DOUBLE QUEEN 410 DOUBLE QUEENENLARGED 412 KING STUDIO 414 EFFICIENCY 407 PANELS 409A ELEVATORLOBBY417LINENS & HOUSEKEEPING 409 EFFICIENCYADA-M-RI 403 CONNECTINGCORRIDOR 400 EFFICIENCY 408 EFFICIENCY 405 1,746 SF GUESTCORRIDOR 415 ELEV 2 113 ELEV 1 111 LINEN CHUTE 140 BALCONY 401A BALCONY 402A BALCONY 419A BALCONY 421A BALCONY 423A BALCONY 425A BALCONY 435A BALCONY 437A STAIR 1 406 STAIR 2 432 IDF 409B ELECTRICAL 415A 2 A-302 3 A-302 A-4161 A-412 1 DAC 409C 1 A-302 8.1 9 4 1.1 A A K N P Q 2 7 8 6 10 H J 2 A-301 L KING STUDIO 420 KING STUDIO 419 KING STUDIO 421 DOUBLEQUEEN 422 KING STUDIO 423 DOUBLE QUEEN 424 KING STUDIO 426 KING STUDIO 425 EFFICIENCY 427 EFFICIENCY 428 EFFICIENCY 429 KING STUDIO 430 EFFICIENCY 431 EFFICIENCY 433 EFFICIENCY 434 DOUBLEQUEEN 436 DOUBLEQUEEN 435 KING STUDIO 437 KING STUDIO 418 KING STUDIO 416 KING STUDIO 404 P3.3 P3.1 P3.1 P3.2 P3.3 P4.2 P4.2 P3.2 P3.1 P3.1 XE1/2 XE1/2 XE1/2 XE1/2 XE1/2 XE1/2 XE1/2 XE1/2 XE1/2 XD2 XE1/2 XD2 XE1/2 XE1/2 P5.1 P3.2P3.2 P3.2 P3.2 P3.1 P3.1 P3.2 P3.1P3.2 XE1/2 XE1/2 XE1/2 XE1/2 XE1/2 XE1/2P3.1 XE1/2 P3.2P4.1P4.3P3.1P3.2P3.2P3.2P3.2P3.2P3.1P3.2P3.1 XE1/2XE1/2 XE1/2 XE1/2XW1XE1/2XE1/2 P3.1 P5.1P3.2 ADA MOBILITY ROOM ADA COMMUNICATION FEATURES ROOM ADA SYMBOL LEGEND 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216OVERALL 4TH FLOORPLAN A-104 FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 3/32" = 1'-0"14TH FLOOR PLAN 0'6' 12'24' SCALE: 3/32" = 1'-0" 5. SEE STRUCTURAL TO VERIFY LOCATIONS OF ALL SHEAR WALLS. SEE ELEVATIONS TO VERIFY EXTERIOR FINISHMATERIAL AND COLOR. 4. PROVIDE AN ACCESSIBLE ROUTE AND COMPLIANT WHEELCHAIR LOCATIONS IN EACH OF THE PUBLIC SPACESPROVIDED FOR GUEST USE. 3. BOTH VISUAL AND NOTIFICATION DEVICES SHALL BE PROVIDED IN PUBLIC AND COMMON AREAS. THE SYSTEMMUST BE DESIGNED TO BE ABLE TO BE INTEGRATED INTO EMPLOYEE WORK SPACES AND MUST COMPLY WITHNFPA 72 AND STATE, LOCAL AND FEDERAL REGULATIONS. DEVICES MUST BE LOCATED SO THE LIGHT IS VISIBLE INEACH REQUIRED SPACE. 2. ALL WALLS IN BATH SHALL BE MOISTURE RESISTANT GYPSUM BOARD. BATH CEILING SHALL BE EXTERIORGYPSUM BOARD. 1. REFER TO HOMEWOOD STANDARDS FOR FLOORING REQUIREMENTS IN EACH AREA. GENERAL NOTES- FLOOR PLANS EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV Revision Schedule Number Description Date W/DW/DDN DN A-2012 A-202 A-201 1 2 5 3 3.1 6.1 2.1 D C.1 FG ML.1 KING STUDIOENLARGED 538 KING1-BEDROOM 502 KING1-BEDROOMENLARGED 501 DOUBLE QUEEN 510 KING STUDIO 504 DOUBLEQUEENADA-M-T 512 KING STUDIO 514 EFFICIENCY 507 ELEVATORLOBBY517LINENS & HOUSEKEEPING 509 EFFICIENCYADA-M-T 503 CONNECTINGCORRIDOR 500 EFFICIENCY 508 EFFICIENCY 505 GUESTCORRIDOR 515 ELEV 2 113 ELEV 1 111 LINEN CHUTE 140 BALCONY 501ABALCONY 502A BALCONY 519A BALCONY 521A BALCONY 523A BALCONY 525A BALCONY 535A BALCONY 537A STAIR 1 506 STAIR 2 532 E 1 A-301 IDF 509B ELECTRICAL 515A C C B B 1 ROOF ACCESS 539 2 A-302 3 A-302 A-421 1DAC 509C 1 A-302 8.1 9 4 1.1 A K N P Q A-5013 A-5023 2 PANELS 509A 7 8 6 10 H J 2 A-301 L KING STUDIO 520 KING STUDIO 519 KING STUDIO 521 DOUBLEQUEEN 522 KING STUDIO 523 DOUBLE QUEEN 524 KING STUDIO 526 KING STUDIO 525 EFFICIENCY 527 EFFICIENCY 528 EFFICIENCY 529 KING STUDIO 530 EFFICIENCY 531 EFFICIENCY 533 EFFICIENCY 534 DOUBLEQUEEN 536 DOUBLEQUEEN 535 KING STUDIO 537 KING STUDIO 518 KING STUDIO 516 P3.3 P3.1 P3.1 P3.2 P3.3 P4.2 P4.2 P3.2 P3.1 P3.1 XE1/2 XE1/2 XE1/2 XE1/2 XE1/2 XE1/2 XE1/2 XE1/2 XE1/2 XD2 XE1/2 XD2 XE1/2 XE1/2 P5.1 P3.2P3.2 P3.2 P3.2 P3.1 P3.1 P3.2 P3.1P3.2 XE1/2 XE1/2 XE1/2 XE1/2 XE1/2 XE1/2P3.1 XE1/2 P3.2P4.1P4.3P3.1P3.2P3.2P3.2P3.2P3.2P3.1P3.2P3.1 XE1/2XE1/2 XE1/2 XE1/2XW1XE1/2XE1/2 P3.1 P5.1P3.2 ADA MOBILITY ROOM ADA COMMUNICATION FEATURES ROOM ADA SYMBOL LEGEND 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216OVERALL 5TH FLOORPLAN A-105 FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 3/32" = 1'-0"15TH FLOOR PLAN 0'6' 12'24' SCALE: 3/32" = 1'-0" 5. SEE STRUCTURAL TO VERIFY LOCATIONS OF ALL SHEAR WALLS. SEE ELEVATIONS TO VERIFY EXTERIOR FINISHMATERIAL AND COLOR. 4. PROVIDE AN ACCESSIBLE ROUTE AND COMPLIANT WHEELCHAIR LOCATIONS IN EACH OF THE PUBLIC SPACESPROVIDED FOR GUEST USE. 3. BOTH VISUAL AND NOTIFICATION DEVICES SHALL BE PROVIDED IN PUBLIC AND COMMON AREAS. THE SYSTEMMUST BE DESIGNED TO BE ABLE TO BE INTEGRATED INTO EMPLOYEE WORK SPACES AND MUST COMPLY WITHNFPA 72 AND STATE, LOCAL AND FEDERAL REGULATIONS. DEVICES MUST BE LOCATED SO THE LIGHT IS VISIBLE INEACH REQUIRED SPACE. 2. ALL WALLS IN BATH SHALL BE MOISTURE RESISTANT GYPSUM BOARD. BATH CEILING SHALL BE EXTERIORGYPSUM BOARD. 1. REFER TO HOMEWOOD STANDARDS FOR FLOORING REQUIREMENTS IN EACH AREA. GENERAL NOTES- FLOOR PLANS EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV Revision Schedule Number Description Date A-2012 A-202 A-202 A-201 1 2 1 5 3 3.1 6.1 2.1 D C.1 FG ML.1E 1 A-301 C C B B 1 2 A-302 3 A-302 11165' - 8 1/2"17' - 6 3/4"1 A-302 8.1 9 4 1.1 A A K N P Q 2 7 8 6 10 H J1/4" / 1'-0"1/4" / 1'-0"1/4" / 1'-0"1/4" / 1'-0"1/4" / 1'-0"1/4" / 1'-0"1" / 1'-0"1" / 1'-0"1/4" / 1'-0"1/4" / 1'-0" 2 A-301 L 1 11 1 1 2 3 1 4 TYP. 5 6 7 7 84TYP. 9 9 9 9 9 98 8 8 10 11 12 13 14 15 16 17 TYP. 18 19 TYP. 19TYP. 20 20 20 2020 20 20 12' - 3 3/4" 23' - 6"23' - 6"1 A-507 21 21 21 21 21 22 22 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216ROOF PLAN A-106 FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 3/32" = 1'-0"1ROOF PLAN 0'6' 12'24' SCALE: 3/32" = 1'-0" KEYNOTES - ROOF PLANS 1 ROOF MOUNTED MECHANICAL EQUIPMENT - SEE MECHANICAL 2 ELEVATOR PENTHOUSE 3 LINEN CHUTE VENT 4 ROOF DRAIN AND OVERFLOW ROOF DRAIN - SEE PLUMBING.RUN RAIN LEADERS THROUGH CHASES OR WALLS FOR ENTIRERUN. 5 ROOF HATCH 6 SAFETY GATE FOR ROOF HATCH WITH FRONT GATE CLOSURE 7 POTENTIAL SOLAR PANEL AREA 8 CANOPY BELOW 9 BALCONY CANOPY BELOW 10 PORTE COCHERE BELOW 11 FAUX ROOF PARAPET 12 TRELLIS OVER POOL MEP ROOM 13 TRELLIS OVER OUTDOOR KITCHEN 14 ROOF OVER POOL ROOM BELOW, SLOPE TO DRAIN AT MIN. 1/4"= 1'0". 15 SMOKING SHELTER 16 ALTERNATING TREAD STAIR TO ROOF FROM 5TH FLOOR STAIR 17 PARAPETS- SEE DETAILS 18 TAPERED INSULATION CRICKET 19 WALKWAY/PROTECTION PAD IN CONTRASTING COLOR TOROOF 20 MEMBRANE ROOF, SLOPE STRUCTURE TO DRAIN TOWARDSROOF DRAINS. 21 EMERGENCY OVERFLOW SCUPPER 22 MINIMUM ROOF INSULATION DEPTH AT VALLEY: 4" (R-22.5) 4. COORDINATE ROOF DAVITS AND STANCHIONS PER OSHA ANDOWNER PREFERENCE. 3. COORDINATE SOLAR DESIGN WITH SOLAR PANEL DESIGNER. 2. KEEP ROOF MOUNTED EQUIPMENT AWAY FROM PARAPETSWHEN POSSIBLE TO REDUCE SIGHT LINES. 1. ALL ROOFTOP EQUIPMENT, PLUMBING, VENTS, CONDENSINGUNITS, EXHAUST FANS, BOISER FLUES, ETC. ARE TO BECONCEALED FROM VIEW BEHIND PARAPET WALLS. GENERAL NOTES - ROOF WEIGHTED MAIN ROOF INSULATION CALCULATIONS R-VAL OF FRACTIONALPORTION OF ROOF AREA PERCENTAGE PORTION R-VALNORTH TRIANGULAR PORTION: 939.56 SF 5.28% OF ROOF * 53.076 = R-2.8EAST RECTANGULAR PORTION: 2,059.25 SF 1.57% OF ROOF * 43.44 = R-5.03WEST RECTANGULAR PORTION: 2,961.49 SF 16.64% OF ROOF * 43.44 = R-7.23NORTH RECTANGULAR PORTION: 4,910.36 SF 27.6% OF ROOF * 43.44 = R-11.99SOUTH RECTANGULAR PORTION: 6,089.02 SF 34.22% OF ROOF * 43.44 = R-14.87EAST TRIANGULAR PORTION: 833.16 SF 4.67% OF ROOF * 53.076 = R-2.49 TOTAL MAIN ROOF AREA 17,792.83 SF TOTAL WEIGHTED ROOF R-VALUE R-44.4 EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV Revision Schedule Number Description Date DDDD WWWW DN UP DN UP A-2012 A-202 A-202 A-201 1 2 1 5 3 3.1 6.1 2.1 D C.1 FG ML.1E 1 A-301 C C B B 1 2 A-302 3 A-302 11 1 A-302 8.1 9 4 1.1 A A K N P Q 2 23' - 6"23' - 6"44' - 0"1' - 11"11' - 2 3/4"16' - 7"3 A-505 7 8 6 10 H H J 12' - 0"1/4" / 1'-0"1/4" / 1'-0"1/4" / 1'-0"1/4" / 1'-0" 2 A-301 1 A-505 L1/4" / 1'-0"1/4" / 1'-0"5' - 8"13' - 1 1/2"1/4" / 1'-0" 15' - 0 3/4" RC-5 15' - 1" RC-6 11' - 7 3/4" RC-3 15' - 9 1/2" 13' - 7 1/4"1/2" / 1'-0"1/4" / 1'-0"1/4" / 1'-0"8 4TYP. 8 8 12 13 14 15 11/32" / 1'-0"15/64" / 1'-0"1/4" / 1'-0"1/4" / 1'-0"1/4" / 1'-0"1/4" / 1'-0"737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216LOWER ROOF PLAN A-107 FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 0'6' 12'24' SCALE: 3/32" = 1'-0" 3/32" = 1'-0"1LOWER ROOF PLAN KEYNOTES - ROOF PLANS 1 ROOF MOUNTED MECHANICAL EQUIPMENT - SEE MECHANICAL 2 ELEVATOR PENTHOUSE 3 LINEN CHUTE VENT 4 ROOF DRAIN AND OVERFLOW ROOF DRAIN - SEE PLUMBING.RUN RAIN LEADERS THROUGH CHASES OR WALLS FOR ENTIRERUN. 5 ROOF HATCH 6 SAFETY GATE FOR ROOF HATCH WITH FRONT GATE CLOSURE 7 POTENTIAL SOLAR PANEL AREA 8 CANOPY BELOW 9 BALCONY CANOPY BELOW 10 PORTE COCHERE BELOW 11 FAUX ROOF PARAPET 12 TRELLIS OVER POOL MEP ROOM 13 TRELLIS OVER OUTDOOR KITCHEN 14 ROOF OVER POOL ROOM BELOW, SLOPE TO DRAIN AT MIN. 1/4"= 1'0". 15 SMOKING SHELTER 16 ALTERNATING TREAD STAIR TO ROOF FROM 5TH FLOOR STAIR 17 PARAPETS- SEE DETAILS 18 TAPERED INSULATION CRICKET 19 WALKWAY/PROTECTION PAD IN CONTRASTING COLOR TOROOF 20 MEMBRANE ROOF, SLOPE STRUCTURE TO DRAIN TOWARDSROOF DRAINS. 21 EMERGENCY OVERFLOW SCUPPER 22 MINIMUM ROOF INSULATION DEPTH AT VALLEY: 4" (R-22.5) 4. COORDINATE ROOF DAVITS AND STANCHIONS PER OSHA ANDOWNER PREFERENCE. 3. COORDINATE SOLAR DESIGN WITH SOLAR PANEL DESIGNER. 2. KEEP ROOF MOUNTED EQUIPMENT AWAY FROM PARAPETSWHEN POSSIBLE TO REDUCE SIGHT LINES. 1. ALL ROOFTOP EQUIPMENT, PLUMBING, VENTS, CONDENSINGUNITS, EXHAUST FANS, BOISER FLUES, ETC. ARE TO BECONCEALED FROM VIEW BEHIND PARAPET WALLS. GENERAL NOTES - ROOF EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV Revision Schedule Number Description Date 5 3 3.1 6.1 2.1 D C.1E MEN'SRESTROOM 116 WOMEN'SRESTROOM 115 MEETINGSTORAGE 119 MEETINGROOM 120 GUESTSTORAGE 118 FITNESS 114 ELEV 2 113 ELEV 1 111 ELEVATORLOBBY117LAUNDRYLOUNGE 112 EMPLOYEEROOM 110 WATERHEATER & FIRE 108 EMP RR ADA 110AEMP RR 110B POOL &SPLASH PAD 101 POOL RESTROOM 102 ELECTRICAL 104 STAIR 1 106 PUBLICCORRIDOR 100 BOH LAUNDRY 105 LINENSTORAGE 109 HOUSEKEEPINGOFFICE 109A LINEN CHUTE 140 LINENDISCHARGE &SORTING 107 POOL MEP 103 CL-A10' - 0" CL-B11' - 6" CL-B29' - 0" CL-A10' - 0" CL-B29' - 0" CL-B29' - 0" CL-B10' - 0"CL-C10' - 0"CL-A10' - 0" CL-B114' - 8 3/4" CL-A11' - 0" CL-B29' - 0" CL-B8' - 0" CL-B212' - 0" C C B B 1 CL-A10' - 0" CL-B29' - 0" CL-B114' - 8 3/4" 3 A-302 CL-B114' - 8 3/4" CL-A10' - 0" 8.1 9 4 1.1 A A-131 1 2 BOH DRYERS 105A 43 SF VESTIBULE 100A/1 A-112/1 A-112 7 8 6 10 CL-B8' - 0" CL-B211' - 4" CL-B12' - 4" CL-B19' - 0"2' - 6"0' - 7 1/2"CL-C10' - 0" CL-A10' - 0" CL-B10' - 0" CEILING LEGEND CL-A (2' X 2' ACT TILES) CL-A WHITE, FINE TEXTURE, CONCEALED SUSPENSION SYSTEM CL-A1 GREY, FINE TEXTURE, CONCEALED SUSPENSION SYSTEM CL-A2 WHITE, WASHABLE, CLEAN ROOM SUSPENSION SYSTEM CL-B (1 HR GWB) CL-B SUSPENDED SYSTEM, 1 LAYER TYPE X GWB, PT-01 FINISH CL-B1 DIRECT-ATTACHED, 1 LAYER TYPE X GWB, PT-01 FINISH CL-B2 SUSPENDED SYSTEM, 1 LAYER EXTERIOR-RATED GWB, PT-01 FINISH CL-B3 DIRECT-ATTACHED, 1 LAYER EXTERIOR-RATED GWB, PT-01 FINISH CL-C (2 HR GWB) CL-C SUSPENDED SYSTEM, SEE DETAIL, PT-01FINISH CL-D (FIBER CEMENT, EXTERIOR/SOFFIT) CL-D SUSPENDED SYSTEM, 1 LAYER 1/2" FIBER CEMENT, PT-01FINISH CL-D1 DIRECT-ATTACHED, 1 LAYER 1/2" FIBER CEMENT, PT-01FINISH CL-E (FIBER CEMENT, EXTERIOR/SOFFIT) CL-E SUSPENDED SYSTEM, 1 LAYER TYPE X GWB, 1 LAYER PLYWOOD WITH PLASTIC LAMINATE FINISH NOTE: REFER TO FF&E PACKAGE AND SPECIFICATION BOOK FOR FURNITURE AND FINISH SPECIFICATIONS 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216OVERALL 1ST FLOORREFLECTED CEILINGPLAN - WEST WING A-111 FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 1/8" = 1'-0" Reference: 3 / A-002 11ST FLOOR REFLETED CEILING PLAN - WEST WING 0'4' 8'16' SCALE: 1/8" = 1'-0" EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV Revision Schedule Number Description Date SDSDSD SDSD SD 5 FG M L.1 E 2 A-302 11 9 4 K N P Q MEETINGROOM 120 VESTIBULE 122 COURTYARDSTORAGE 141 GUESTCORRIDOR 139 LOBBY 121 CL-D9' - 0" CL-A11' - 0" CL-B11' - 2" CL-B7' - 1" CL-A10' - 0" CL-B314' - 8 3/4" CL-A12' - 2" CL-A12' - 2" CL-A211' - 0" FOOD PREP 123 SALES OFFICE 126 GM OFFICE 125 OPEN OFFICE 124 ELECTRICAL 128 CL-A9' - 0" CL-B114' - 6"KING STUDIOADA-M-T 138 KING STUDIO 137 DOUBLE QUEEN 135 DOUBLEQUEEN 136 EFFICIENCY 133 EFFICIENCY 134 EFFICIENCY 131 EFFICIENCY 129 KING STUDIO 130 STAIR 2 132 OWNER'SOFFICE 127 PUBLICCORRIDOR 121A VESTIBULE 139A ELECTRICAL 139B CL-B29' - 0"/1 A-111/1 A-111 3 A-505 7 8 6 10 HJ CL-D10' - 5"CL-D10' - 5" CL-D13' - 10"CL-D13' - 10" CL-B10' - 0" 2 A-301 1 A-505 CL-B10' - 0" CL-D114' - 3"1/2" / 1'-0"CL-D19' - 0" CL-B12' - 2" CL-B12' - 2" CL-B12' - 2" 14' - 11 1/2" 13' - 11 1/4" CL-E10' - 10" CL-B11' - 2" Trellis 10'-4" A-4082 11 A-510 Typ 11 A-510 Typ 14 A-510 13 A-510 12 A-510 15 A-510 TypCL-A12' - 2" CL-A112' - 2" CL-B10' - 0" L 11' - 7 3/4" RC-3 11' - 7 3/4" RC-4 17' - 3 3/4" RB-117' - 3 3/4" RB-1 RC-510' - 0" CEILING LEGEND CL-A (2' X 2' ACT TILES) CL-A WHITE, FINE TEXTURE, CONCEALED SUSPENSION SYSTEM CL-A1 GREY, FINE TEXTURE, CONCEALED SUSPENSION SYSTEM CL-A2 WHITE, WASHABLE, CLEAN ROOM SUSPENSION SYSTEM CL-B (1 HR GWB) CL-B SUSPENDED SYSTEM, 1 LAYER TYPE X GWB, PT-01 FINISH CL-B1 DIRECT-ATTACHED, 1 LAYER TYPE X GWB, PT-01 FINISH CL-B2 SUSPENDED SYSTEM, 1 LAYER EXTERIOR-RATED GWB, PT-01 FINISH CL-B3 DIRECT-ATTACHED, 1 LAYER EXTERIOR-RATED GWB, PT-01 FINISH CL-C (2 HR GWB) CL-C SUSPENDED SYSTEM, SEE DETAIL, PT-01FINISH CL-D (FIBER CEMENT, EXTERIOR/SOFFIT) CL-D SUSPENDED SYSTEM, 1 LAYER 1/2" FIBER CEMENT, PT-01FINISH CL-D1 DIRECT-ATTACHED, 1 LAYER 1/2" FIBER CEMENT, PT-01FINISH CL-E (FIBER CEMENT, EXTERIOR/SOFFIT) CL-E SUSPENDED SYSTEM, 1 LAYER TYPE X GWB, 1 LAYER PLYWOOD WITH PLASTIC LAMINATE FINISH NOTE: REFER TO FF&E PACKAGE AND SPECIFICATION BOOK FOR FURNITURE AND FINISH SPECIFICATIONS 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216OVERALL 1ST FLOORREFLECTED CEILINGPLAN - EAST WING A-112 FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 1/8" = 1'-0"11ST FLOOR REFLECTED CEILING PLAN - EAST WING 0'4' 8'16' SCALE: 1/8" = 1'-0" 0'4" 8"1' 4" SCALE: 1 1/2" = 1'-0" EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV Revision Schedule Number Description Date SDSD SD SD SD SD SD SD SD SDSDSDSDSDSDSDSDSDSD5 3 3.1 6.1 2.1 D C.1E 1 A-301 C C B B 1 3 A-302 1 A-302 8.1 9 4 1.1 A 2 KING STUDIO 319 KING STUDIO 320 KING STUDIO 318 KING STUDIO 316 LINENS &HOUSEKEEPING 309 KING STUDIO 314 DOUBLEQUEENENLARGED 312 DOUBLE QUEEN 310 EFFICIENCY 308 STAIR 1 306 KING STUDIO 304 KING1-BEDROOM 302 EFFICIENCY ENLARGED 303 KING1-BEDROOMADA-M-T 301 EFFICIENCY 305 EFFICIENCY 307 GUESTCORRIDOR 315ELEVATORLOBBY317ELEV 1 111 ELEV 2 113 CONNECTINGCORRIDOR 300 LINEN CHUTE 140 IDF 309B 7 8 6 10 CL-A8' - 0" CL-B8' - 6" CL-B19' - 8 3/4" CEILING LEGEND CL-A (2' X 2' ACT TILES) CL-A WHITE, FINE TEXTURE, CONCEALED SUSPENSION SYSTEM CL-A1 GREY, FINE TEXTURE, CONCEALED SUSPENSION SYSTEM CL-A2 WHITE, WASHABLE, CLEAN ROOM SUSPENSION SYSTEM CL-B (1 HR GWB) CL-B SUSPENDED SYSTEM, 1 LAYER TYPE X GWB, PT-01 FINISH CL-B1 DIRECT-ATTACHED, 1 LAYER TYPE X GWB, PT-01 FINISH CL-B2 SUSPENDED SYSTEM, 1 LAYER EXTERIOR-RATED GWB, PT-01 FINISH CL-B3 DIRECT-ATTACHED, 1 LAYER EXTERIOR-RATED GWB, PT-01 FINISH CL-C (2 HR GWB) CL-C SUSPENDED SYSTEM, SEE DETAIL, PT-01FINISH CL-D (FIBER CEMENT, EXTERIOR/SOFFIT) CL-D SUSPENDED SYSTEM, 1 LAYER 1/2" FIBER CEMENT, PT-01FINISH CL-D1 DIRECT-ATTACHED, 1 LAYER 1/2" FIBER CEMENT, PT-01FINISH CL-E (FIBER CEMENT, EXTERIOR/SOFFIT) CL-E SUSPENDED SYSTEM, 1 LAYER TYPE X GWB, 1 LAYER PLYWOOD WITH PLASTIC LAMINATE FINISH NOTE: REFER TO FF&E PACKAGE AND SPECIFICATION BOOK FOR FURNITURE AND FINISH SPECIFICATIONS 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216OVERALL TYP. 2ND TO5TH FLOOR REFLECTEDCEILING PLAN - WESTWING A-113 FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 0'6' 12'24' SCALE: 3/32" = 1'-0" 1/8" = 1'-0" Reference: 3 / A-002 1TYPICAL 2ND-RTH FLOOR RCP - WEST WING EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV Revision Schedule Number Description Date SDSD SDSDSDSD SDSD SDSD SDSDSD5 FG ML.1 E KING STUDIOADA-M-RI 338 KING STUDIO 337 DOUBLEQUEEN 335 DOUBLEQUEEN 336 EFFICIENCY 333 EFFICIENCY 334 STAIR 2 332 EFFICIENCY 331 EFFICIENCY 329 EFFICIENCY 327 KING STUDIO 325 KING STUDIO 323 KING STUDIO 321 KING STUDIO 319 KING STUDIO 330 EFFICIENCY 328 KING STUDIO 326 DOUBLE QUEEN 324 DOUBLEQUEEN 322 KING STUDIO 320 KING STUDIO 318 GUESTCORRIDOR 315ELEVATORLOBBY317 ELECTRICAL 315A 2 A-302 9 4 K N P Q 7 8 6 10 HJ 2 A-301 L CEILING LEGEND CL-A (2' X 2' ACT TILES) CL-A WHITE, FINE TEXTURE, CONCEALED SUSPENSION SYSTEM CL-A1 GREY, FINE TEXTURE, CONCEALED SUSPENSION SYSTEM CL-A2 WHITE, WASHABLE, CLEAN ROOM SUSPENSION SYSTEM CL-B (1 HR GWB) CL-B SUSPENDED SYSTEM, 1 LAYER TYPE X GWB, PT-01 FINISH CL-B1 DIRECT-ATTACHED, 1 LAYER TYPE X GWB, PT-01 FINISH CL-B2 SUSPENDED SYSTEM, 1 LAYER EXTERIOR-RATED GWB, PT-01 FINISH CL-B3 DIRECT-ATTACHED, 1 LAYER EXTERIOR-RATED GWB, PT-01 FINISH CL-C (2 HR GWB) CL-C SUSPENDED SYSTEM, SEE DETAIL, PT-01FINISH CL-D (FIBER CEMENT, EXTERIOR/SOFFIT) CL-D SUSPENDED SYSTEM, 1 LAYER 1/2" FIBER CEMENT, PT-01FINISH CL-D1 DIRECT-ATTACHED, 1 LAYER 1/2" FIBER CEMENT, PT-01FINISH CL-E (FIBER CEMENT, EXTERIOR/SOFFIT) CL-E SUSPENDED SYSTEM, 1 LAYER TYPE X GWB, 1 LAYER PLYWOOD WITH PLASTIC LAMINATE FINISH NOTE: REFER TO FF&E PACKAGE AND SPECIFICATION BOOK FOR FURNITURE AND FINISH SPECIFICATIONS 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216OVERALL TYP. 2ND TO5TH FLOOR REFLECTEDCEILING PLAN - EASTWING A-114 FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 0'4' 8'16' SCALE: 1/8" = 1'-0" 1/8" = 1'-0" Reference: 3 / A-002 1TYPICAL 2ND-5TH FLOOR RCP - EAST WING EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV Revision Schedule Number Description Date DDDD WWWW UP 5 3 3.1 6.1 2.1 D C.1E 1 A-301 C C B B 1 3 A-302 A-4359 171 SF MEN'SRESTROOM 116 172 SF WOMEN'SRESTROOM 115 81 SF MEETINGSTORAGE 119 406 SF MEETINGROOM 120176 SFGUESTSTORAGE118801 SF FITNESS 114 257 SF LAUNDRYLOUNGE 112 432 SF EMPLOYEEROOM 110 361 SF WATERHEATER & FIRE 108 50 SF EMP RR ADA 110A30 SF EMP RR 110B 2,152 SF POOL &SPLASH PAD 101 80 SF POOLRESTROOM 102 548 SF ELECTRICAL 104 191 SF STAIR 1 106 711 SF PUBLICCORRIDOR 100 750 SF BOH LAUNDRY 105 85 SF LINENSTORAGE 109 56 SF HOUSEKEEPINGOFFICE 109A 131 SF LINEN DISCHARGE &SORTING 107 204 SF POOL MEP 103 176 SFELEVATORLOBBY11764 SF ELEV 2 113 68 SF ELEV 1 111 13 SF LINEN CHUTE 140 A-4429 /1 A-122/1 A-122 W-BW-BW-BW-B W-B W-B W-B W-B W-B W-A CW-F CW-F CW-F CW-GCW-GCW-GCW-GCW-G 43 SF VESTIBULE 100A A-4441 CW-H CW-L W-EW-DW-E CW-K D-116 D-115 D-119 D-114 D-112 D-108 D-110 D-110AD-110B D-109 D-105 D-107 D-104 D-105A D-106 D-101A D-103 D-101 D-108A D-120 CW-K CW-K 8.1 9 4 1.1 A A A-5011 2 CW-F CW-F CW-F D-102 D-100A P1.1 P3.1 P3.1 P1.1 P1.1 <varies> P3.3 P3.1 P1.1 P6 P3.1 P3.1 P3.1 P4.2 P4.1 P4.2 P3.1P3.3 P2.2P1.1 P2.1 P7 P1.2P5.1 P5.3 P2.3 P3.3P3.3 P8P8 P8P8 P3.1 P3.3 P2.2 P1.1 P1.2 P1.2 P5.4 XS3 XS3XS3 XS3 XS1 XE1/2 XS2 XE1/2 XE3 XE3 <varies> XS1 XS1XE1/2 7 8 6 10 A-452 1 P2.2 P1.2 XS1 P5.2 P5.1 P5.4 D-117XE1/2 XE8 XE4 P6 P6 P5.5 CS-01 P6 D-104A P2.1 P3.1 D-100 D-106A 30' - 6 3/4"5' - 10 1/4"19' - 6 1/2"19' - 1"6' - 0"19' - 7 1/4"4' - 7 1/2" 6' - 1 1/4" 8' - 8 3/4"15' - 2 3/4" 3' - 11 1/4" 15' - 0 1/2"9' - 3" 5' - 10"13' - 5" 2' - 2"23' - 6 3/4"4' - 2 1/2"30' - 6 3/4"5' - 10 1/4"28' - 8 1/2" 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 992161ST FLOORCONTRUCTION PLAN -WEST WING A-121 FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 0'4' 8'16' SCALE: 1/8" = 1'-0" 1/8" = 1'-0" Reference: 1 / A-101 11ST FLOOR CONSTRUCTION PLAN - WEST WING EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV Revision Schedule Number Description Date UP 5 6.1 C.1 F F G G M M L.1 L.1 E E 1 A-301 C C 2 A-302 11 171 SF MEN'SRESTROOM 116 172 SF WOMEN'SRESTROOM 115 81 SF MEETING STORAGE 119 406 SF MEETINGROOM 120 176 SF GUESTSTORAGE 118 150 SF VESTIBULE 122 46 SF COURTYARDSTORAGE 141 428 SF GUESTCORRIDOR 1392,670 SF LOBBY 121 131 SF LINEN DISCHARGE &SORTING 107 104 SF OWNER'SOFFICE 127 95 SF GM OFFICE 125106 SF SALES OFFICE 126 233 SF OPEN OFFICE 124 135 SF ELECTRICAL 128 594 SF FOOD PREP 123 538 SF DOUBLEQUEEN 135 353 SF EFFICIENCY 133 176 SFELEVATORLOBBY117352 SF EFFICIENCY 129 353 SF EFFICIENCY 131 419 SF KING STUDIO 130 64 SF ELEV 2 113 68 SF ELEV 1 111 13 SF LINEN CHUTE 140 226 SF STAIR 2 132 10 SF ELECTRICAL 139B 353 SF EFFICIENCY 134 541 SF DOUBLEQUEEN 136 483 SF KING STUDIO ADA-M-T 138 54 SF PATIO 135A 54 SF PATIO 137A A-4345/1 A-121/1 A-121 W-BW-BW-B W-B CW-D CW-D CW-ECW-E CW-C CW-H CW-K D-119 D-120 CW-N D-124 D-128 D-125D-126 D-127 D-139 D-139A D-139B D-X32 D-141 D-122A 8.1 99 4 K K N N P P Q Q A-502 1 A-5041 A-4311 P3.3 P1.2 P3.3 P3.1 P3.3 P3.3 P4.2 P4.2 P1.2 P1.2 P1.2 P3.3 P2.2 P2.2 P2.3 P1.1 P3.2P4.1 P4.3 P3.1P3.1P5.1 P3.3 P1.2 XS2 XE3 XE3XE3XE3 XS1 XE1/2 XE1/2 XS1 XS1 XE1/2 XE3 XE3 XE1/2 XS1 XE3 XS4 XS1 XS1XE1/2 XE1/2 XE1/2 P1.2 426 SF KING STUDIO 137 XE1/2 P5.1 7 8 6 10 HJ A-450 1 2 A-301 1 A-505 L CW-M XS4 P3.1 CW-D D-132 D-117D-121 D-122 D-123 D-115 D-116 W-B 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 992161ST FLOORCONTRUCTION PLAN -EAST WING A-122 FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 0'4' 8'16' SCALE: 1/8" = 1'-0" 1/8" = 1'-0" Reference: 1 / A-101 11ST FLOOR ENLARGED CONSTRUCTION PLAN - EAST WING EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV REVISION SCHEDULE # DESCRIPTION DATE 2 ADDENDUM 2 6/21/2024 2 W/DW/DA-202 A-2022 1 5 3 3.1 6.1 2.1 D C.1 C.1 E E 1 A-301 C C B B 1 3 A-302 /1 A-124/1 A-124 W-H W-C W-G W-C 619 SF KING1-BEDROOM X02 716 SF KING1-BEDROOM ENLARGED X01 402 SF EFFICIENCYENLARGED X03420 SF KING STUDIO X04 58 SF BALCONY X01A 58 SF BALCONY X02A 420 SF KING STUDIO X16 420 SF KING STUDIO X18420 SF KING STUDIO X20422 SF KING STUDIO X14 568 SF DOUBLE QUEENENLARGED X12 541 SF DOUBLE QUEEN X10 355 SF EFFICIENCY X08 356 SF EFFICIENCY X05 497 SF LINENS & HOUSEKEEPING X09 255 SF ENGINEERINGOFFICE & STORAGE 207 98 SF PBX/MDF 207A 157 SF ELEVATOR LOBBY X17 D-X17 D-207 191 SF STAIR 1 X06 D-207B D-207A 1,746 SF GUEST CORRIDOR X15 8.1 9 4 1.1 A A A-5012 2 EFFICIENCYX07353 SF 5 SF IDF X09B 6 SF DAC X09C <varies> P3.2 P5.4 P5.1 P4.2 P5.5 P3.2 P1.2P1.2 P3.2 P3.1 <varies> P3.2P3.4 P1.2 P1.2 P4.2 P4.2P4.1 XE1/2 XE1/2 XE1/2 XE1/2 XE1/2 XE1/2 XE1/2 XE1/2 XE1/2 XE3 <varies> XE1/2 XE1/2 <varies> A-419A1 7 8 6 10 98 SF CONNECTINGCORRIDOR X00 W-C A-453 1 A-4532 6' - 0"19' - 7 1/4"19' - 5 1/2"19' - 2"15' - 0 1/2"9' - 3"19' - 2 3/4"25' - 8 3/4"4' - 2 1/2"30' - 6 3/4"5' - 10 1/4"19' - 6 1/2"19' - 1" 30' - 6 3/4"5' - 10 1/4"28' - 8 1/2"15' - 0 1/2"15' - 0 3/4"15' - 7"27' - 9 1/4"737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216TYPICAL 2ND-5THFLOOR CONTRUCTIONPLAN - WEST WING A-123 FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 0'4' 8'16' SCALE: 1/8" = 1'-0" 1/8" = 1'-0" Reference: 1 / A-102 1TYPICAL 2ND-5TH FLOOR CONSTRUCTION PLAN - WEST WING EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV Revision Schedule Number Description Date 5 C.1 FG M L.1 E 1 A-301 2 A-302 11/1 A-123/1 A-123 W-C 420 SF KING STUDIO X19 420 SF KING STUDIO X21 420 SF KING STUDIO X23 420 SF KING STUDIO X25 354 SF EFFICIENCY X27 353 SF EFFICIENCY X29 354 SF EFFICIENCY X31 353 SF EFFICIENCY X33 540 SF DOUBLE QUEEN X35 426 SF KING STUDIO X37 420 SF KING STUDIO X18 420 SF KING STUDIO X20 536 SF DOUBLE QUEEN X22 536 SF DOUBLE QUEEN X24420 SF KING STUDIO X26 354 SF EFFICIENCY X28 420 SF KING STUDIO X30 543 SF DOUBLEQUEEN X36 483 SF KING STUDIOADA-M-T X38 157 SF ELEVATORLOBBY X17 D-X17 353 SF EFFICIENCY X34 1,746 SF GUESTCORRIDOR X15 9 4 K N P Q A-502 2 A-504 2 226 SF STAIR 2 X32 68 SF ELEV 1 111 64 SF ELEV 2 113 58 SF BALCONY X19A 58 SF BALCONY X21A 58 SF BALCONY X23A 58 SF BALCONY X25A 57 SF BALCONY X37A 57 SF BALCONY X35A P5.4 P5.1 P4.2 P3.2P3.1P3.2 P3.1 P4.1 P4.3 P1.2 A-411A2A-411A1 <varies> XE1/2XE1/2 XE1/2 XE1/2 XE1/2 XE1/2 XE3 XE1/2 XE1/2 XE1/2 XE1/2 <varies>XE1/2 XE1/2XE1/2 3 A-505 7 8 6 10 HJ 2 A-301 1 A-505 L 19' - 1"19' - 0 3/4"28' - 0"6' - 0"24' - 2 3/4"6' - 1 1/4"23' - 11 3/4"3' - 11 1/4"19' - 0 3/4"14' - 11"19' - 1 1/2"10' - 9"14' - 11 1/4"19' - 1 1/2"19' - 9 1/4" 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216TYPICAL 2ND-5THFLOOR CONTRUCTIONPLAN - EAST WING A-124 FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 0'4' 8'16' SCALE: 1/8" = 1'-0" 1/8" = 1'-0" Reference: 1 / A-102 1TYPICAL 2ND-5TH FLOOR CONSTRUCTION PLAN - EAST WING EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV Revision Schedule Number Description Date DDDD WWWW UP 5 3 3.1 6.1 2.1 D C.1E CB 1 8.1 9 4 1.1 A 171 SF MEN'SRESTROOM 116 172 SF WOMEN'SRESTROOM 115 81 SF MEETING STORAGE 119 406 SF MEETING ROOM 120176 SFGUESTSTORAGE118801 SF FITNESS 114 257 SF LAUNDRYLOUNGE 112 432 SF EMPLOYEEROOM 110 361 SF WATERHEATER & FIRE 108 50 SF EMP RR ADA 110A30 SF EMP RR 110B 2,152 SF POOL &SPLASH PAD 101 80 SF POOLRESTROOM 102 337 SF ELECTRICAL 104 191 SF STAIR 1 106 711 SF PUBLICCORRIDOR 100 750 SF BOH LAUNDRY 105 85 SF LINENSTORAGE 109 56 SF HOUSEKEEPINGOFFICE 109A 131 SF LINENDISCHARGE &SORTING 107 204 SF POOL MEP 103 176 SFELEVATORLOBBY11764 SF ELEV 2 113 68 SF ELEV 1 111 13 SF LINEN CHUTE 140 /1 A-132/1 A-132 43 SF VESTIBULE 100A 2 7 8 6 10 CPT-10CT-10 CPT-12 CT-10 CT-10 CT-10 RES-10 RES-11 CT-10 VCT-01 CT-10 CT-10 CS-01 CS-01 CT-10 CT-10CS-01 CT-10 CPT-14 VCT-01 VCT-01 VCT-01 VCT-01 BOH DRYERS 105ACS-01CS-01 11' - 0"6' - 6" RES-12 RES-13 CT-19 ACT ACOUSTIC CEILING TILEASALUMINUM STOREFRONTCGCORNER GUARDCONC CONCRETE, UNFINISHEDCPCARPETCPTCARPET TILECSCONCRETE, FINISHEDGWBGYPSUM WALL BOARDFCFIBER CEMENTFRPFIBERGLASS-REINFORCEDPLASTICMR GWB MOISTURE-RESISTANT GWBPFPRE-FINISHED DOORPLPLASTIC LAMINATEPTPAINT/POWDER COATQTQUARRY TILERBRUBBER BASERESRESILIENT TILE FLOORSCSTAMPED CONCRETESFSPECIALTY FINISH (KNOCK DOWN)SS ENGINEERED SOLID SURFACESTSTONESTLSTAINLESS STEELSTRUC STRUCTURE ABOVEVCTVINYL COMPOSITE TILEWCVINYL WALL COVERINGWDWOOD-LOOK ALUMINUM SLATS AND BATTENSWPSCREEN WALL NOTE: REFER TO FF&E PACKAGE AND SPECIFICATION BOOK FOR FURNITURE AND FINISH SPECIFICATIONS FINISH LEGEND 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 992161ST FLOOR FINISH PLAN- WEST WING A-131 FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 1/8" = 1'-0"11ST FLOOR FINISH PLAN - WEST WING 0'4' 8'16' SCALE: 1/8" = 1'-0" EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV REVISION SCHEDULE # DESCRIPTION DATE 2 ADDENDUM 2 6/21/2024 22 22 22 22 2 2 2 2 2 2 2 2 UP 5 C.1 FG ML.1E 11 9 4 K N P Q 81 SF MEETINGSTORAGE 119 406 SF MEETINGROOM 120 176 SF GUEST STORAGE 118 150 SF VESTIBULE 122 46 SF COURTYARDSTORAGE 141 428 SF GUESTCORRIDOR 1392,670 SF LOBBY 121 131 SF LINEN DISCHARGE &SORTING 107 104 SF OWNER'SOFFICE 127 95 SF GM OFFICE 125106 SF SALES OFFICE 126 233 SF OPEN OFFICE 124 135 SF ELECTRICAL 128 594 SF FOOD PREP 123 538 SF DOUBLE QUEEN 135 353 SF EFFICIENCY 133 176 SFELEVATORLOBBY117352 SF EFFICIENCY 129 353 SF EFFICIENCY 131 419 SF KING STUDIO 130 64 SF ELEV 2 113 68 SF ELEV 1 111 13 SF LINEN CHUTE 140 226 SF STAIR 2 132 10 SF ELECTRICAL 139B 353 SF EFFICIENCY 134 541 SF DOUBLEQUEEN 136 483 SF KING STUDIO ADA-M-T 138 54 SF PATIO 135A 54 SF PATIO 137A /1 A-131/1 A-131 7 8 6 10 H J CPT-12 CPT-11 CPT-11 CT-10 L CPT-14 CT-10 CPT-10 CT-10 QT-01 CS-01 CS-01 RES-12 CPT-14CT-10 ICE/WATER 118A VCT-01 CPT-12 ACT ACOUSTIC CEILING TILEASALUMINUM STOREFRONTCGCORNER GUARDCONC CONCRETE, UNFINISHEDCPCARPETCPTCARPET TILECSCONCRETE, FINISHEDGWBGYPSUM WALL BOARDFCFIBER CEMENTFRPFIBERGLASS-REINFORCEDPLASTICMR GWB MOISTURE-RESISTANT GWBPFPRE-FINISHED DOORPLPLASTIC LAMINATEPTPAINT/POWDER COATQTQUARRY TILERBRUBBER BASERESRESILIENT TILE FLOORSCSTAMPED CONCRETESFSPECIALTY FINISH (KNOCK DOWN)SS ENGINEERED SOLID SURFACESTSTONESTLSTAINLESS STEELSTRUC STRUCTURE ABOVEVCTVINYL COMPOSITE TILEWCVINYL WALL COVERINGWDWOOD-LOOK ALUMINUM SLATS AND BATTENSWPSCREEN WALL NOTE: REFER TO FF&E PACKAGE AND SPECIFICATION BOOK FOR FURNITURE AND FINISH SPECIFICATIONS FINISH LEGEND 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 992161ST FLOOR FINISH PLAN- EAST WING A-132 FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 1/8" = 1'-0"11ST FLOOR FLOOR FINISH PLAN - EAST WING 0'4' 8'16' SCALE: 1/8" = 1'-0" EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV REVISION SCHEDULE # DESCRIPTION DATE 2 ADDENDUM 2 6/21/2024 2 2 W/DW/D5 3 3.1 6.1 2.1 D C.1EC C B B 1 8.1 9 4 1.1 A A /1 A-134/1 A-134 619 SF KING1-BEDROOM X02 716 SF KING1-BEDROOM ENLARGED X01 402 SF EFFICIENCYENLARGED X03420 SF KING STUDIO X04 58 SF BALCONY X01A 58 SF BALCONY X02A 420 SF KING STUDIO X16 420 SF KING STUDIO X18420 SF KING STUDIO X20422 SF KING STUDIO X14 568 SF DOUBLE QUEENENLARGED X12 541 SF DOUBLE QUEEN X10 355 SF EFFICIENCY X08 356 SF EFFICIENCY X05 497 SF LINENS & HOUSEKEEPING X09 255 SF ENGINEERINGOFFICE &STORAGE 207 98 SF PBX/MDF 207A 157 SF ELEVATOR LOBBY X17 191 SF STAIR 1 X06 1,746 SF GUESTCORRIDOR X15 2 EFFICIENCYX07353 SF A-419A1 7 8 6 10 A-4481 A-448 8 CPT-10 CPT-10 CPT-14 VCT-01 VCT-01 VCT-01 ACT ACOUSTIC CEILING TILEASALUMINUM STOREFRONTCGCORNER GUARDCONC CONCRETE, UNFINISHEDCPCARPETCPTCARPET TILECSCONCRETE, FINISHEDGWBGYPSUM WALL BOARDFCFIBER CEMENTFRPFIBERGLASS-REINFORCEDPLASTICMR GWB MOISTURE-RESISTANT GWBPFPRE-FINISHED DOORPLPLASTIC LAMINATEPTPAINT/POWDER COATQTQUARRY TILERBRUBBER BASERESRESILIENT TILE FLOORSCSTAMPED CONCRETESFSPECIALTY FINISH (KNOCK DOWN)SS ENGINEERED SOLID SURFACESTSTONESTLSTAINLESS STEELSTRUC STRUCTURE ABOVEVCTVINYL COMPOSITE TILEWCVINYL WALL COVERINGWDWOOD-LOOK ALUMINUM SLATS AND BATTENSWPSCREEN WALL NOTE: REFER TO FF&E PACKAGE AND SPECIFICATION BOOK FOR FURNITURE AND FINISH SPECIFICATIONS FINISH LEGEND 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216TYPICAL 2ND-5THFLOOR FINISH PLAN -WEST WING A-133 FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 1/8" = 1'-0"1TYPICAL 2ND-5TH FLOOR FINISH PLAN - WEST WING 0'4' 8'16' SCALE: 1/8" = 1'-0" EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV REVISION SCHEDULE # DESCRIPTION DATE 2 ADDENDUM 2 6/21/2024 2 2 2 5 C.1 F F G G M L.1 E 11 9 4 K N P Q /1 A-133/1 A-133 420 SF KING STUDIO X19 420 SF KING STUDIO X21 420 SF KING STUDIO X23 420 SF KING STUDIO X25354 SF EFFICIENCY X27 353 SF EFFICIENCY X29 354 SF EFFICIENCY X31 353 SF EFFICIENCY X33 540 SF DOUBLEQUEEN X35 426 SF KING STUDIO X37 420 SF KING STUDIO X18 420 SF KING STUDIO X20 536 SF DOUBLE QUEEN X22 536 SF DOUBLEQUEEN X24 420 SF KING STUDIO X26 354 SF EFFICIENCY X28 420 SF KING STUDIO X30 543 SF DOUBLEQUEEN X36 483 SF KING STUDIO ADA-M-T X38 157 SF ELEVATORLOBBY X17 353 SF EFFICIENCY X34 1,746 SF GUESTCORRIDOR X15 68 SF ELEV 1 111 64 SF ELEV 2 113 58 SF BALCONY X19A 58 SF BALCONY X21A 58 SF BALCONY X23A 58 SF BALCONY X25A 57 SF BALCONY X37A 57 SF BALCONY X35A 226 SF STAIR 2 X32 A-411A 1 7 8 6 10 H HJ A-4506 A-451 3 L CPT-10 CPT-14 CPT-10 VCT-01 ELECTRICAL X15A ? ? ACT ACOUSTIC CEILING TILEASALUMINUM STOREFRONTCGCORNER GUARDCONC CONCRETE, UNFINISHEDCPCARPETCPTCARPET TILECSCONCRETE, FINISHEDGWBGYPSUM WALL BOARDFCFIBER CEMENTFRPFIBERGLASS-REINFORCEDPLASTICMR GWB MOISTURE-RESISTANT GWBPFPRE-FINISHED DOORPLPLASTIC LAMINATEPTPAINT/POWDER COATQTQUARRY TILERBRUBBER BASERESRESILIENT TILE FLOORSCSTAMPED CONCRETESFSPECIALTY FINISH (KNOCK DOWN)SS ENGINEERED SOLID SURFACESTSTONESTLSTAINLESS STEELSTRUC STRUCTURE ABOVEVCTVINYL COMPOSITE TILEWCVINYL WALL COVERINGWDWOOD-LOOK ALUMINUM SLATS AND BATTENSWPSCREEN WALL NOTE: REFER TO FF&E PACKAGE AND SPECIFICATION BOOK FOR FURNITURE AND FINISH SPECIFICATIONS FINISH LEGEND 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216TYPICAL 2ND-5THFLOOR FINISH PLAN -EAST WING A-134 FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 1/8" = 1'-0"1TYPICAL 2ND-5TH FLOOR FINISH PLAN - EAST WING 0'4' 8'16' SCALE: 1/8" = 1'-0" EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV REVISION SCHEDULE # DESCRIPTION DATE 2 ADDENDUM 2 6/21/2024 2 FLOOR 10' - 0" FLOOR 216' - 0" FLOOR 327' - 0" FLOOR 438' - 0" FLOOR 549' - 0" MAIN ROOF61' - 2" D C.1FGML.1 E BO ROOF STRUC.60' - 0" LOW PARAPET63' - 10" MIDDLE PARAPET65' - 10" HIGH PARAPET69' - 10" C B SITE-0' - 6" 2 A-302 MAX BLDG HEIGHT71' - 2"16' - 0"11' - 0" 11' - 0" 11' - 0" 11' - 0"71' - 2"1 A-302 AKNPQHJ 2 A-301 L 1 A-507 XE-B XE-CXE-C XS-F XS-F XE-D XE-AXE-A XE-B XE-D XE-CXS-F XE-AXE-B XE-C XS-F XE-B XE-C W-K W-K W-K W-KW-H W-H W-H W-HW-C W-C W-C W-CW-H W-K W-H W-H W-K W-K W-K W-K W-C W-C W-C W-CW-K D-G04W-KD-G04 D-G04 D-G04 W-K D-G04W-KD-G04 D-G04A D-G04 W-K D-G04W-KD-G04 D-G04 D-G04 W-K D-G04W-KD-G04 D-G04 D-G04 D-G04W-KW-KD-G04 D-G04W-KW-KD-G04 D-G04W-KW-KD-G04 D-G04W-KW-KD-G04 W-H W-H W-H W-HW-H W-H W-H W-HW-H W-H W-H W-HW-H W-H W-H W-HW-KD-G04W-KD-G04 D-141W-HW-HW-HW-KD-G04W-KD-G04 D-G04D-G04 D-G04D-G04 D-G04D-G04 W-KW-K W-KW-K W-KW-K CW-A1CW-A2CW-B D-121 CW-C CW-G CW-G CW-G CW-G CW-G XS-F XE-AXE-A XS-F PC-B XS-FPC-B XE-A XE-B XE-C XE-C PT-E PT-E PT-E PT-E PT-E PT-E PT-E PT-E PT-EPT-E PT-EPT-E PT-E PT-E PT-EPT-E PT-E PT-E PT-E PT-E PT-E PT-E PC-04 PC-04 PC-04 PC-04 PC-04 PT-E PC-04 PC-04 PC-04 PC-04 PC-04 PC-04 PC-04 PC-04 PC-04 PC-04 PC-04 PC-04 PC-04 FLOOR 10' - 0" FLOOR 216' - 0" FLOOR 327' - 0" FLOOR 438' - 0" FLOOR 549' - 0" MAIN ROOF61' - 2" 533.16.12.1 1 A-301 BO ROOF STRUC.60' - 0" LOW PARAPET63' - 10" MIDDLE PARAPET65' - 10" HIGH PARAPET69' - 10" SITE-0' - 6" 1 3 A-302 MAX BLDG HEIGHT71' - 2"71' - 2"11' - 0"11' - 0"11' - 0"11' - 0"16' - 0"165' - 8 1/2" 118.194 1.1278610 1 A-505 XE-CXE-AXE-BXE-B XE-CXE-CXE-A XS-FXE-B XS-F XE-A XS-F XS-F XE-A XE-BXW-G XS-F W-H W-H W-H W-HW-H W-H W-H W-H CW-F CW-F D-101D-139B W-C W-C W-C W-CW-H W-H W-H W-H W-H W-H W-H PT-E PC-04 PT-E PT-E PT-E PC-04 PC-04 PC-04 PT-E PT-E PT-E PT-E PT-E PT-E PT-E PC-04 PC-04 PC-04 PC-04 PC-04 PT-E D-104 PC-B CW-L XS-F XE-B XE-B XE-C XE-C PT-E PT-EPT-A PC-04 XS-F 13' - 9" CLEARPC-B EQEQ XE-C XS-F XE-A/ PT-A / PC-ABEIGE EIFS/MATCH SHERWIN-WILLIAMSPAINT / POWDER-COAT SW6154 NACRE (263-C2) XE-B / PT-B / PC-BLIGHT BROWN EIFS / MATCH SHERWIN-WILLIAMSPAINT / POWDER-COAT SW7153 SANDERLING (248-C5) GRAPHIC EXTERIOR MATERIAL LEGEND XE-C/ PT-C / PC-CMID BROWN EIFS /MATCH SHERWIN-WILLIAMSPAINT / POWDER-COAT SW7525 TREE BRANCH (288-C7) XE-D / PT-D / PC-DRED BROWN EIFS / MATCH SHERWIN-WILLIAMSPAINT / POWDER-COAT SW6118 LEATHER BOUND (291-C7) XE-E/ PT-E / PC-EDARK BROWN EIFS / MATCH SHERWIN-WILLIAMSPAINT / POWDER-COAT SW7510 CHATEAU BROWN (242-C7) XS-FMANUFACTURED STONE CULTURED STONE VENEER CLADDING COUNTRY LEDGESTONEASHFALL XW-GWOOD-LOOK KNOTWOOD, 6" CLADDINGALUMINUM CLADDING WESTERN RED CEDAR 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216BUILDING ELEVATIONS A-201 FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 3/32" = 1'-0" Reference: 1 / A-101 1NORTH ELEVATION 3/32" = 1'-0" Reference: 1 / A-101 2EAST ELEVATION 3 0'6' 12'24' SCALE: 3/32" = 1'-0" 1 2 TYP. 4TYP. 5TYP.6TYP. 7TYP. 8 TYP. 12 TYP. 2215TYP. 2 TYP.6TYP.8TYP. 12 TYP. 16 102115TYP. 9 11 11 13212110 7TYP.21 2121 2020 KEYNOTES - ELEVATIONS 1 EMERGENCY OVERFLOW ROOF SCUPPER 2 VISIBILE CONTROL JOINT. LOCATE VISIBLE AS INDICATED ONDRAWINGS. ADDITIONAL NECESSARY CONTROL JOINTS TO BEINVISIBILE AND LOCATED PER MANUFACTURER'SSPECIFICATIONS. 3 PERMANENT ACCESS DOORS TO INTERIOR OF ALL PARAPETSWHERE SIGNS ARE LOCATED TO BE PROVIDED BYCONTRACTOR. CONTRACTOR TO FURNISH AND CONNECTPRIMARY ELECTRICAL SERVICE INSIDE PARAPET WALL.COORDINATE SERVICE FOR SIGN WITH ELECTRICAL. 4 PTAC VENT. WHERE PTAC VENT IS NOT INTEGRATED INTOWINDOW SYSTEM, MATCH FINISH COLOR TO ADJACENTSURFACE. VERIFY EACH COLORS WITH ARCHITECT. 5 PRE-FINISHED ALUMINUM WINDOWS. 6 PRE-FINISHED ALUMINUM WINDOWS WITH INTEGRATED PTACLOUVERS. 7 ALUMINUM STOREFRONT 8 PARAPET 9 SIGN INDICATING CLEAR HEIGHT UNDER PORTE-COCHERE.COLOR TO CONTRAST WITH BACKGROUND. AHJ TO MAKEFINAL DETERMINATION ON FORMAT, LOCATION, COLOR ANDSIZE. 10 INSULATED, GALVANIZED, HOLLOW METAL DOOR AND FRAME. 11 COVERED SECONDARY ENTRY 12 EXTERIOR WALL SCONCE FOR BALCONY 13 DRYER AND DRYER ROOM VENTS. 14 AUTOMATIC ALUMINUM SLIDING DOOR 15 DECORATIVE CONCRETE CAP AT MATERIAL CHANGE. 16 ALL ROOFTOP EQUIPMENT TO BE ADAQUATELY SCREENEDFROM PUBLIC VIEW. 17 GUEST LAUNDRY ROOM VENTING. 18 ROOF HATCH AND SAFETY RAILING/GATE. 19 BUILDING ADDRESS NUMBER, 14" TALL TEXT. COLOR TOCONTRAST WITH BACKGROUND. AHJ TO MAKE FINALDETERMINATION ON FORMAT, LOCATION, COLOR AND SIZE. 20 WATERPROOF GFCI EXTERIOR OUTLET IN LOCKABLE BOX. 21 FREEZEPROOF HOSE BIBB IN LOCKABLE BOX. 22 KITCHEN HOOD VENT 23 KNOX BOX. FINAL LOCATION, MOUNTING HEIGHT, KEYING, SIZETO BE DETERMINED BY AHJ. 24 HOT WATER ROOM VENTING. 4. GUESTROOMS OR PUBLIC SPACES WITH SIGNAGE ON EXTERIORWALLS MUST HAVE ELECTRICAL PENETRATIONS AND/ORREMOTETRANSFORMERS COORDINATED AND/OR INSTALLED PRIOR TO... 3. RACEWAYS / WIREWAYS ARE NOT ALLOWED 2. ELECTRICAL AND FINAL CONNECTION BY CONTRACTOR.ELECTRICAL REQUIREMENTS MAY BE OBTAINED FROM SIGNCOMPANY. 1. MINIMUM 5/8" PLYWOOD BACKERBOARD REQUIRED AT SIGNLOCATIONS. AREA SHOULD COVER ENTIRE LENGTH AND HEIGHTOF FASCIA OR SPACE AVAILABLE FOR SIGN. GENERAL NOTES - BUILDING SIGNAGE 4. SEE ELECTRICAL FOR EXTERIOR LIGHTING. 3. USE HIGH-IMPACT MESH AT BOTTOM 8' AROUND ENTIREBUILDING WHERE EIFS IS INSTALLED. 2. ALL EXTERIOR VENTS, GRILLES, MECHANICAL LOUVERS ANDEXTERIOR HOLLOW METAL DOORS TO BE FINISHED TO MATCHADJACENT EXTERIOR MATERIAL. 1. LOCATE ALL ROOFTOP EQUIPMENT SO THAT IT IS EITHER OUTOF SIGHTLINES OR ADAQUATELY SCREENED. GENERAL NOTES - ELEVATIONS 20 2020 21 20 20 EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV Revision Schedule Number Description Date FLOOR 10' - 0" FLOOR 216' - 0" FLOOR 327' - 0" FLOOR 438' - 0" FLOOR 549' - 0" MAIN ROOF61' - 2" DC.1FG ML.1E BO ROOF STRUC.60' - 0" LOW PARAPET63' - 10" MIDDLE PARAPET65' - 10" HIGH PARAPET69' - 10" CB SITE-0' - 6" 2 A-302 MAX BLDG HEIGHT71' - 2"11' - 0"11' - 0"11' - 0"11' - 0"16' - 0"71' - 2"1 A-302 A K N P Q 3 A-505 H J 2 A-301 L 1 A-507 XE-B XE-C XE-A XS-FXE-E XE-BXE-A XS-F XW-G XE-A XS-F XE-E XE-B XE-A XS-F XE-B XE-CXS-FXW-G XE-A W-BW-BW-B W-C W-C W-C W-CW-G W-G W-G W-GW-G W-G W-G W-GW-G W-G W-G W-G W-BW-BCW-D CW-D D-122 CW-M CW-D W-G W-G W-G W-GW-G W-G W-G W-GW-G W-G W-G W-G W-H W-H W-H W-H W-BW-B W-B W-G W-H W-G W-G W-G W-G W-H W-H W-H W-H W-G W-G W-G W-G W-G W-G W-G W-G W-G W-G XS-F PT-E XS-FXS-F PC-04 XE-B XE-A XE-B D-G107PC-E XE-E XE-E XE-E XS-F XW-G XS-F PT-E PT-E FLOOR 10' - 0" FLOOR 216' - 0" FLOOR 327' - 0" FLOOR 438' - 0" FLOOR 549' - 0" MAIN ROOF61' - 2" 533.16.12.1 1 A-301 BO ROOF STRUC.60' - 0" LOW PARAPET63' - 10" MIDDLE PARAPET65' - 10" HIGH PARAPET69' - 10" SITE-0' - 6" 1 3 A-302 11' - 0"11' - 0"11' - 0"11' - 0"16' - 0"165' - 8 1/2" MAX BLDG HEIGHT71' - 2"71' - 2"118.1941.1278610 1 A-505 XE-C XS-F XE-A XE-B XE-B XE-C XE-A XS-F XW-G XS-F XE-C D-108AD-106AD-100 W-H W-H W-H W-HW-G W-G W-G W-GW-H W-H W-H W-HW-G W-G W-G W-GW-G W-G W-G W-GW-G W-G W-G W-G W-BW-BW-BW-BW-BW-A CW-FCW-FCW-FCW-F CW-H PC-BPC-B PT-EXS-F XE-CXE-A XE-BXE-C XE-B PT-E PC-04 PC-C PT-E PT-E PC-04 XS-F 4' - 9"PT-E PT-E PT-E PT-E PC-04 PC-04 PC-04 EQEQ 17' - 3 1/4"XE-A/ PT-A / PC-ABEIGE EIFS/MATCH SHERWIN-WILLIAMSPAINT / POWDER-COAT SW6154 NACRE (263-C2) XE-B / PT-B / PC-BLIGHT BROWN EIFS / MATCH SHERWIN-WILLIAMSPAINT / POWDER-COAT SW7153 SANDERLING (248-C5) GRAPHIC EXTERIOR MATERIAL LEGEND XE-C/ PT-C / PC-CMID BROWN EIFS /MATCH SHERWIN-WILLIAMSPAINT / POWDER-COAT SW7525 TREE BRANCH (288-C7) XE-D / PT-D / PC-DRED BROWN EIFS / MATCH SHERWIN-WILLIAMSPAINT / POWDER-COAT SW6118 LEATHER BOUND (291-C7) XE-E/ PT-E / PC-EDARK BROWN EIFS / MATCH SHERWIN-WILLIAMSPAINT / POWDER-COAT SW7510 CHATEAU BROWN (242-C7) XS-FMANUFACTURED STONE CULTURED STONE VENEER CLADDING COUNTRY LEDGESTONEASHFALL XW-GWOOD-LOOK KNOTWOOD, 6" CLADDINGALUMINUM CLADDING WESTERN RED CEDAR 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216BUILDING ELEVATIONS A-202 FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 3/32" = 1'-0" Reference: 1 / A-101 1SOUTH ELEVATION 3/32" = 1'-0" Reference: 1 / A-101 2WEST ELEVATION 0'6' 12'24' SCALE: 3/32" = 1'-0" 3 3 KEYNOTES - ELEVATIONS 1 EMERGENCY OVERFLOW ROOF SCUPPER 2 VISIBILE CONTROL JOINT. LOCATE VISIBLE AS INDICATED ONDRAWINGS. ADDITIONAL NECESSARY CONTROL JOINTS TO BEINVISIBILE AND LOCATED PER MANUFACTURER'SSPECIFICATIONS. 3 PERMANENT ACCESS DOORS TO INTERIOR OF ALL PARAPETSWHERE SIGNS ARE LOCATED TO BE PROVIDED BYCONTRACTOR. CONTRACTOR TO FURNISH AND CONNECTPRIMARY ELECTRICAL SERVICE INSIDE PARAPET WALL.COORDINATE SERVICE FOR SIGN WITH ELECTRICAL. 4 PTAC VENT. WHERE PTAC VENT IS NOT INTEGRATED INTOWINDOW SYSTEM, MATCH FINISH COLOR TO ADJACENTSURFACE. VERIFY EACH COLORS WITH ARCHITECT. 5 PRE-FINISHED ALUMINUM WINDOWS. 6 PRE-FINISHED ALUMINUM WINDOWS WITH INTEGRATED PTACLOUVERS. 7 ALUMINUM STOREFRONT 8 PARAPET 9 SIGN INDICATING CLEAR HEIGHT UNDER PORTE-COCHERE.COLOR TO CONTRAST WITH BACKGROUND. AHJ TO MAKEFINAL DETERMINATION ON FORMAT, LOCATION, COLOR ANDSIZE. 10 INSULATED, GALVANIZED, HOLLOW METAL DOOR AND FRAME. 11 COVERED SECONDARY ENTRY 12 EXTERIOR WALL SCONCE FOR BALCONY 13 DRYER AND DRYER ROOM VENTS. 14 AUTOMATIC ALUMINUM SLIDING DOOR 15 DECORATIVE CONCRETE CAP AT MATERIAL CHANGE. 16 ALL ROOFTOP EQUIPMENT TO BE ADAQUATELY SCREENEDFROM PUBLIC VIEW. 17 GUEST LAUNDRY ROOM VENTING. 18 ROOF HATCH AND SAFETY RAILING/GATE. 19 BUILDING ADDRESS NUMBER, 14" TALL TEXT. COLOR TOCONTRAST WITH BACKGROUND. AHJ TO MAKE FINALDETERMINATION ON FORMAT, LOCATION, COLOR AND SIZE. 20 WATERPROOF GFCI EXTERIOR OUTLET IN LOCKABLE BOX. 21 FREEZEPROOF HOSE BIBB IN LOCKABLE BOX. 22 KITCHEN HOOD VENT 23 KNOX BOX. FINAL LOCATION, MOUNTING HEIGHT, KEYING, SIZETO BE DETERMINED BY AHJ. 24 HOT WATER ROOM VENTING. 4. GUESTROOMS OR PUBLIC SPACES WITH SIGNAGE ON EXTERIORWALLS MUST HAVE ELECTRICAL PENETRATIONS AND/ORREMOTETRANSFORMERS COORDINATED AND/OR INSTALLED PRIOR TO... 3. RACEWAYS / WIREWAYS ARE NOT ALLOWED 2. ELECTRICAL AND FINAL CONNECTION BY CONTRACTOR.ELECTRICAL REQUIREMENTS MAY BE OBTAINED FROM SIGNCOMPANY. 1. MINIMUM 5/8" PLYWOOD BACKERBOARD REQUIRED AT SIGNLOCATIONS. AREA SHOULD COVER ENTIRE LENGTH AND HEIGHTOF FASCIA OR SPACE AVAILABLE FOR SIGN. GENERAL NOTES - BUILDING SIGNAGE 4. SEE ELECTRICAL FOR EXTERIOR LIGHTING. 3. USE HIGH-IMPACT MESH AT BOTTOM 8' AROUND ENTIREBUILDING WHERE EIFS IS INSTALLED. 2. ALL EXTERIOR VENTS, GRILLES, MECHANICAL LOUVERS ANDEXTERIOR HOLLOW METAL DOORS TO BE FINISHED TO MATCHADJACENT EXTERIOR MATERIAL. 1. LOCATE ALL ROOFTOP EQUIPMENT SO THAT IT IS EITHER OUTOF SIGHTLINES OR ADAQUATELY SCREENED. GENERAL NOTES - ELEVATIONS 1 15TYP. 16 1 1 21 19 21 21 2020 20202023241720115TYP.6TYP. 12TYP. 2TYP. 2TYP. 6TYP.5TYP. 1010 10 7TYP. 1816 7TYP. 8TYP. 8 TYP. 14 EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV Revision Schedule Number Description Date FLOOR 10' - 0" FLOOR 216' - 0" FLOOR 327' - 0" FLOOR 438' - 0" FLOOR 549' - 0" MAIN ROOF61' - 2" C.1FGML.1 E LOW PARAPET63' - 10" MIDDLE PARAPET65' - 10" HIGH PARAPET69' - 10" C B SITE-0' - 6" 2 A-302 ELEV 1 111 EMPLOYEEROOM 110 DOUBLEQUEEN 210 DOUBLEQUEEN 310 DOUBLE QUEEN 410 DOUBLEQUEEN 510 LINENS &HOUSEKEEPING 509 LINENS &HOUSEKEEPING 409 LINENS &HOUSEKEEPING 309 BOH LAUNDRY 105ELEVATORLOBBY 117 ELEVATORLOBBY 217 ELEVATORLOBBY 317 ELEVATOR LOBBY 417 ELEVATORLOBBY 517 KING STUDIO 519 KING STUDIO 419 KING STUDIO 319 KING STUDIO 219 LOBBY 121 FOOD PREP 123 EFFICIENCY 129 EFFICIENCY 131 EFFICIENCY 133 DOUBLEQUEEN 135 KING STUDIO 137 KING STUDIO 237 KING STUDIO 337 KING STUDIO 437 KING STUDIO 537 DOUBLEQUEEN 535 DOUBLE QUEEN 435 DOUBLEQUEEN 335 DOUBLE QUEEN 235 EFFICIENCY 533 EFFICIENCY 433 EFFICIENCY 333 EFFICIENCY 233 EFFICIENCY 231 EFFICIENCY 331 EFFICIENCY 431 EFFICIENCY 531 EFFICIENCY 529 EFFICIENCY 429 EFFICIENCY 329 EFFICIENCY 229 EFFICIENCY 527 EFFICIENCY 427 EFFICIENCY 327 EFFICIENCY 227 KING STUDIO 225 KING STUDIO 325 KING STUDIO 425 KING STUDIO 525 KING STUDIO 523 KING STUDIO 423 KING STUDIO 323 KING STUDIO 223 KING STUDIO 421 KING STUDIO 321 KING STUDIO 521 KING STUDIO 221 16' - 0"11' - 0" 11' - 0" 11' - 0" MAX BLDG HEIGHT71' - 2"71' - 2"LINENS &HOUSEKEEPING 209 1 A-302 AKNPQHJ2 A-301 L 12' - 2"1 A-507 FLOOR 10' - 0" FLOOR 216' - 0" FLOOR 327' - 0" FLOOR 438' - 0" FLOOR 549' - 0" MAIN ROOF61' - 2" 533.16.1 2.1 1 A-301 SITE-0' - 6" 1 3 A-302 MAX BLDG HEIGHT71' - 2" 118.194 1.1278610 DOUBLE QUEEN 524 KING STUDIO 523 LOBBY 121VESTIBULE 122 DOUBLE QUEEN 424 DOUBLE QUEEN 324 DOUBLEQUEEN 224 KING STUDIO 423 KING STUDIO 323 KING STUDIO 223 A-5053 10' - 0"12' - 2"11' - 0"11' - 0"11' - 0"16' - 0"0' - 6"71' - 2"A-5071Sim 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216BUILDING SECTIONS A-301 FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 0'6' 12'24' SCALE: 3/32" = 1'-0" 3/32" = 1'-0" Reference: 1 / A-101 1LONGITUDINAL SECTION THROUGH LOBBY 3/32" = 1'-0" Reference: 1 / A-101 2CROSS SECTION THROUGH LOBBY EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV Revision Schedule Number Description Date FLOOR 10' - 0" FLOOR 216' - 0" FLOOR 327' - 0" FLOOR 438' - 0" FLOOR 549' - 0" MAIN ROOF61' - 2" 53 1 A-301 LOW PARAPET63' - 10" MIDDLE PARAPET65' - 10" HIGH PARAPET69' - 10" SITE-0' - 6" 1 3 A-302 MAX BLDG HEIGHT71' - 2" 1194278610 1 A-505 KING1-BEDROOMENLARGED 501 KING 1-BEDROOMENLARGED 401 KING1-BEDROOM ADA-M-T 301 KING1-BEDROOMENLARGED 201 EFFICIENCYADA-M-T 503 EFFICIENCYADA-M-RI 403 EFFICIENCYENLARGED 303 EFFICIENCYENLARGED 203 EFFICIENCY 505 EFFICIENCY 405 EFFICIENCY 305 EFFICIENCY 205 EFFICIENCY 507 EFFICIENCY 407 EFFICIENCY 307 ENGINEERINGOFFICE &STORAGE 207 PBX/MDF 207A LINENS &HOUSEKEEPING 509 LINENS &HOUSEKEEPING 409 LINENS &HOUSEKEEPING 309 KING STUDIO 516 KING STUDIO 416 KING STUDIO 316 KING STUDIO 216 LINENS &HOUSEKEEPING 209 LINENSTORAGE 109 MEN'SRESTROOM 116 WOMEN'SRESTROOM 115 PUBLICCORRIDOR 100 GUESTCORRIDOR 215 GUESTCORRIDOR 315 GUESTCORRIDOR 415 GUESTCORRIDOR 515 BOH LAUNDRY 105 POOL &SPLASH PAD 101 FLOOR 10' - 0" FLOOR 216' - 0" FLOOR 327' - 0" FLOOR 438' - 0" FLOOR 549' - 0" MAIN ROOF61' - 2" DFGME LOW PARAPET63' - 10" MIDDLE PARAPET65' - 10" HIGH PARAPET69' - 10" C B SITE-0' - 6" 2 A-302 2,152 SF POOL &SPLASH PAD 101 420 SF KING STUDIO 204 402 SF EFFICIENCY ENLARGED 203 420 SF KING STUDIO 304 420 SF KING STUDIO 404 420 SF KING STUDIO 504 402 SF EFFICIENCY ENLARGED 303 399 SF EFFICIENCY ADA-M-RI 403 399 SF EFFICIENCYADA-M-T 503 16' - 0"11' - 0" 11' - 0" 11' - 0" MAX BLDG HEIGHT71' - 2" 58' - 5 1/4"71' - 2"204 SF POOL MEP 103 1 A-302 AKNPQHJ 2 A-301 L 12' - 2"POOLRESTROOM 102 FLOOR 10' - 0" FLOOR 216' - 0" FLOOR 327' - 0" FLOOR 438' - 0" FLOOR 549' - 0" MAIN ROOF61' - 2" 1 A-301 LOW PARAPET63' - 10" MIDDLE PARAPET65' - 10" SITE-0' - 6" EFFICIENCY 131 EFFICIENCY 231 EFFICIENCY 331 EFFICIENCY 431 EFFICIENCY 531 ROOF ACCESS 539STAIR 2 532 STAIR 2 432 STAIR 2 332 STAIR 2 232 STAIR 2 132 11' - 0"11' - 0"11' - 0"16' - 0"9786 10 12' - 2" 3/32" = 1'-0" Reference: 1 / A-101 2 CROSS SECTION THROUGH GUESTROOMS IN EAST WING 3/32" = 1'-0" Reference: 1 / A-101 3CROSS SECTION THROUGH POOL 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216BUILDING SECTIONS A-302 FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 0'6' 12'24' SCALE: 3/32" = 1'-0" 3/32" = 1'-0" Reference: 1 / A-101 1LONGITUDINAL SECTION THROUGH POOL EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV Revision Schedule Number Description Date XE7 G-005 G-004 2,116 SF PET AREA 004 OP-701 OF-713 10' - 0"5' - 0"4' - 0"26' - 0 1/2"90.00°26' - 1 3/4"20' - 7 1/2"12' - 11 3/4"90.00°90.00°129.01°90.00°133.26° 64 ' - 6 1 / 2 " 5' - 10 3/4"38' - 1 1/2"OF-713 OP-701 MIN. 8' - 0"MIN. 8' - 0"20' - 0"3' - 0"4' - 0"3' - 6"0' - 6"4' - 6" MIN. 9' - 0" TYP.18' - 0" TYP.TYP.3' - 0"CLR. MIN. 3' - 0"8.33 % MAX.3' - 6"6' - 0" TYP. 4' - 0"6' - 0"4' - 0"SITE LEGEND DUPLEX OUTLET - GFCI DUPLEX OUTLET - WEATHERPROOF/GFCI COMBINED SMOKE/CARBON MONOXIDE DETECTOR OUTDOOR KITCHEN PENDANT (OF-704) FREEZEPROOF WALL HYDRANT POLE HYDRANT 6" ROUND BOLLARD WP S/CO XE-A / PT-A / PC-ABEIGE EIFS/MATCH SHERWIN-WILLIAMSPAINT / POWDER-COAT SW6154 NACRE (263-C2) XE-B / PT-B / PC-BLIGHT BROWN EIFS / MATCH SHERWIN-WILLIAMSPAINT / POWDER-COAT SW7153 SANDERLING (248-C5) GRAPHIC EXTERIOR MATERIAL LEGEND XE-C / PT-C / PC-C MID BROWN EIFS /MATCH SHERWIN-WILLIAMSPAINT / POWDER-COAT SW7525 TREE BRANCH (288-C7) XE-D / PT-D / PC-DRED BROWN EIFS / MATCH SHERWIN-WILLIAMSPAINT / POWDER-COAT SW6118 LEATHER BOUND (291-C7) XE-E / PT-E / PC-E DARK BROWN EIFS / MATCH SHERWIN-WILLIAMSPAINT / POWDER-COAT SW7510 CHATEAU BROWN (242-C7) XS-FMANUFACTURED STONE CULTURED STONE VENEER CLADDING COUNTRY LEDGESTONEASHFALL XW-G / WD-1WOOD-LOOK KNOTWOOD, 6" CLADDINGALUMINUM CLADDING WESTERN RED CEDAR 1/4" = 1'-0" Reference: 1 / A-010 1PET EXERCISE AND RELEIF AREA North Side of Building along Property Line 1/4" = 1'-0" Reference: 1 / A-010 2EV PARKING STALL ENLARGED PLAN 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216ENLARGED EV PARKING& PET RELIEF AREA A-401 FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 0'2' 4'8' SCALE: 1/4" = 1'-0" 4 11 19 KEYNOTES - ENLARGED SITE PLANS 1 CONCRETE WHEEL STOP. PROVIDE AT EACH EV CHARGING/EV READY STALL, ACCESSIBLE STALL ANDSTALL ADJACENT TO AN ACCESSIBLE ROUTE. 2 6" BOLLARD 3 STANDARD STALL - 9' WIDE BY 18' LONG 4 EMERGENCY GENERATOR. SEE ELECTRICAL. PROVIDE DENSE LANDSCAPE SCREENING AT GENERATORENCLOSURE. 5 STANDARD EV CHARGING STALL - 9' WIDE BY 18' LONG 6 STRIPING COLORS: ACCESSIBLE (INCLUDING EV) STALL: BLUE, EV CHARGING STALL: GREEN, STANDARDSTALLS: WHITE. VERIFY STRIPING COLORS WITH AHJ. 7 6" THICK CONCRETE SLAB UNDER TRASH ENCLOSURE. EXTEND SLAB 6' BEYOND ENCLOSURE. 8 TRASH AND RECYCLING DUMPSTERS PROVIDED BY OTHER. 9 GUTTER AND DOWNSPOUT. DOWNSPOUT TO CONNECT TO STORM SEWER. 10 AREA DRAIN. CONNECT TO STORM SEWER. 11 4' HIGH ORNAMENTAL IRON FENCE 12 3' HIGH ORNAMENTAL IRON FENCE ON RETAINING WALL EXTENDING 1' ABOVE GRADE 13 FROST-PROOF WALL HYDRANT IN KEYED BOX. 14 POST HYDRANT 15 EV CHARGING STATION SERVING TWO NON-ACCESSIBLE STALLS, CENTER CHARGING STATIONBETWEEN STALLS. VERIFY CLEARANCES AND DIMENSIONS WITH MANUFACTURER INSTALLATIONINSTRUCTIONS. 16 EV CHARGING STATION SERVING ONE ACCESSIBLE AND ONE NON-ACCESSIBLE SPACE. CHARGINGSTATION MUST BE ON LEVEL WITH ACCESS AISLE. VERIFY CLEARANCES AND DIMENSIONS WITHMANUFACTURER INSTALLATION INSTRUCTIONS. 17 8' WIDE AISLE FOR VAN ACCESSIBLE PARKING STALL. PROVIDE SIGNAGE AS REQUIRED. CHARGINGSTATION TO BE ON LEVEL WITH ACCESS AISLE. PROVIDE BOLLARDS IN FRONT OF CHARGING STATION.DO NOT OBSTRUCT ACCESS AISLE WITH BOLLARDS, WHEEL STOPS OR SIGNAGE. 18 ACCESSIBLE PARKING SPACE - VAN ACCESSIBLE AND EV CHARGING STATION. 8' WIDE BY 20' LONG.PROVIDE SIGNAGE FOR ACCESSIBLE PARKING STALL AS REQUIRED. PROVIDE SIGNAGE INDICATING VANACCESSIBLE STALL. PROVIDE SIGN THAT READS, "ELECTRIC VEHICLE PARKING PREFERRED" BELOWACCESSIBILITY SIGNS. PROVIDE CONCRETE WHEEL STOP. ANY VEHICLE WITH AN ACCESSIBLE PARKINGPERMIT MUST BE ALLOWED TO PARK IN THIS SPACE. 19 SEMI-ENCLOSED SMOKING SHELTER GREATER THAN 25' FROM WINDOWS, DOORS OR AIR INTAKEVENTS. PROVIDE BENCH AT ADA ACCESSIBLE HEIGHT, ASH RECEPTACLE AND TRASH CAN. SCREENWITH LANDSCAPING WHERE POSSIBLE. 20 ACCESSIBLE CURB RAMP TO MEET ALL ACCESSIBILITY REQUIREMENTS. MAXIMUM SLOPE OF RUN 1:12. 21 EMERGENCY SHUT-OFF FOR FIRE PITS AND GAS GRILLS. ENSURE BUTTON IS MOUNTED WITHIN ADAREACH RANGE AND CLEARLY MARKED. 22 TRELLIS ABOVE 23 SURFACE-MOUNTED UTILITY LIGHT 25 ACCESSIBLE ROUTE. MARK WHERE ROUTE CROSSES VEHICULAR TRAFFIC. 29 STAMPED, COLORED CONCRETE APRON AND COURTYARD 30 CANOPY/BALCONY ABOVE 31 40'x100' WEDDING AREA, GREATER THAN 20' FROM BUILDING WALLS. OWNER TO SECURE EVENT PERMITWITH SPOKANE VALLEY FIRE DEPARTMENT PRIOR TO EVENTS. 32 ALL EQUIPMENT (INCLUDING DRYER VENTS) MUST BE SCREENED WITH LANDSCAPING OR OTHERMEANS. 20 1817 25 2 16 111 1 15 1 1 12 11 33555 6 6 8. CATCH BASINS ARE TO BE PLACED SO AS NOT TO INTERFERE WITH DESIGNATED ACCESSIBLE ROUTES. 7. 10% OF NON-PAVED, NON-COVERED AREA OF PROJECT SITE TO BE LANDSCAPED. 6. INSTALL ACCENT PLANTINGS OF ANNUALS AND PERENNIALS AT MAIN ENTRANCE, BUILDING ENTRY, AND SIGNAGEAREAS, AND BACKYARD. 5. SOD ALL AREAS NOT WITHIN PLANTING BEDS. 4. IRRIGATE ALL LANDSCAPED AREAS WITH AUTOMATIC UNDERGROUND SPRINKLER SYSTEM. 3. BUILDING UPLIGHTING SHALL NOT BE OBSTRUCTED BY LANDSCAPE PLANTINGS. 2. REFER TO HILTON SIGNAGE STANDARDS, BRAND STANDARDS AND HILTON marKIT FOR ADDITIONAL INFORMATIONAND PRECISE SIGNAGE REQUIREMENTS. ELECTRICAL FOR BUILDING SIGNAGE AND MONUMENT SIGNAGE SHALLBE PROVIDED AND CONNECTED BY THE CONTRACTOR. 1. COORDINATE LIGHTING LOCATIONS WITH LANDSCAPE PLANTINGS GENERAL NOTES- SITE EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV Revision Schedule Number Description Date S/CO 16' - 5 3/4"15' - 11 3/4"23' - 5 3/4" 6' - 0" 4 A-402 42' - 3"6' - 0"D-001 D-001A G-002G-002A EQEQEQEQEQEQEQEQ 0' - 2"TYP.0' - 6" 10' - 0" TYP. 0' - 6"0' - 6"3' - 3"EQEQEQCLEAR AREA MIN. 10' - 0" X 12' - 0"EQEQEQEQEQEQ XE5 XE5 XE6 XE5 EQEQEQ16' - 5 3/4"15' - 11 3/4"MIN. 17/64" / 1'-0" TYP.MIN. 1/4" / 1'-0" TYP.GFCI GFCI GFCIGFCI GFCI GFCI WP CS-01 CONC CONC 263 SF OUTDOORSTORAGE 001 385 SF OPEN TRASHENCLOSURE 002 10' - 0"G-002AG-002 D-001A D-001 XE5 XE6 STORAGE/TRASH-3' - 0" WD-1WD-1 XE-B XE-B XW-GXW-G PC-BPC-B 1/4" / 1'-0"8' - 2"8' - 6"10' - 0"9' - 1 1/2"3' - 0"2' - 0"STORAGE/TRASH-3' - 0"TYP.2' - 0"XE5XE6XE5 4 A-402EQEQ 4' - 0"4' - 0"CL-B38' - 6" EQ EQ ACT ACOUSTIC CEILING TILEASALUMINUM STOREFRONTCGCORNER GUARDCONC CONCRETE, UNFINISHEDCPCARPETCPTCARPET TILECSCONCRETE, FINISHEDGWBGYPSUM WALL BOARDFCFIBER CEMENTFRPFIBERGLASS-REINFORCEDPLASTICMR GWB MOISTURE-RESISTANT GYPSUM WALL BOARDPLPLASTIC LAMINATEPTPAINT/POWDER COATQTQUARRY TILERBRUBBER BASERESRESILIENT TILE FLOORSCSTAMPED CONCRETESFSPECIALTY FINISH (KNOCK DOWN)SS ENGINEERED SOLID SURFACESTSTONESTLSTAINLESS STEELSTRUC STRUCTURE ABOVEVCTVINYL COMPOSITE TILEWCVINYL WALL COVERINGWDWOOD-LOOK ALUMINUM SLATS AND BATTENSWPSCREEN WALL NOTE: REFER TO FF&E PACKAGE AND SPECIFICATION BOOK FOR FURNITURE AND FINISH SPECIFICATIONS FINISH LEGEND SITE LEGEND DUPLEX OUTLET - GFCI DUPLEX OUTLET - WEATHERPROOF/GFCI COMBINED SMOKE/CARBON MONOXIDE DETECTOR OUTDOOR KITCHEN PENDANT (OF-704) FREEZEPROOF WALL HYDRANT POLE HYDRANT 6" ROUND BOLLARD WP S/CO XE-A / PT-A / PC-ABEIGE EIFS/MATCH SHERWIN-WILLIAMSPAINT / POWDER-COAT SW6154 NACRE (263-C2) XE-B / PT-B / PC-BLIGHT BROWN EIFS / MATCH SHERWIN-WILLIAMSPAINT / POWDER-COAT SW7153 SANDERLING (248-C5) GRAPHIC EXTERIOR MATERIAL LEGEND XE-C / PT-C / PC-CMID BROWN EIFS /MATCH SHERWIN-WILLIAMSPAINT / POWDER-COAT SW7525 TREE BRANCH (288-C7) XE-D / PT-D / PC-DRED BROWN EIFS / MATCH SHERWIN-WILLIAMSPAINT / POWDER-COAT SW6118 LEATHER BOUND (291-C7) XE-E / PT-E / PC-EDARK BROWN EIFS / MATCH SHERWIN-WILLIAMSPAINT / POWDER-COAT SW7510 CHATEAU BROWN (242-C7) XS-FMANUFACTURED STONE CULTURED STONE VENEER CLADDING COUNTRY LEDGESTONEASHFALL XW-G / WD-1 WOOD-LOOK KNOTWOOD, 6" CLADDINGALUMINUM CLADDING WESTERN RED CEDAR 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216ENLARGED STORAGESHED & TRASHENCLOSURE A-402 FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 0'2' 4'8' SCALE: 1/4" = 1'-0" 1/4" = 1'-0" Reference: 1 / A-010 1STORAGE SHED AND TRASH ENCLOSURE Northwest Corner of Parking Lot- Rooms 001 and 002 1/4" = 1'-0"3STORAGE SHED AND TRASH ENCLOSURE SOUTH ELEVATION Northwest Corner of Parking Lot- Rooms 001 and 002 1/4" = 1'-0" Reference: 1 / A-402 4STORAGE SHED AND TRASH ENCLOSURE SECTION Northwest Corner of Parking Lot- Rooms 001 and 002 1/4" = 1'-0"2STORAGE SHED RCP Room 001 KEYNOTES - ENLARGED SITE PLANS 1 CONCRETE WHEEL STOP. PROVIDE AT EACH EV CHARGING/EV READY STALL, ACCESSIBLE STALL ANDSTALL ADJACENT TO AN ACCESSIBLE ROUTE. 2 6" BOLLARD 3 STANDARD STALL - 9' WIDE BY 18' LONG 4 EMERGENCY GENERATOR. SEE ELECTRICAL. PROVIDE DENSE LANDSCAPE SCREENING AT GENERATORENCLOSURE. 5 STANDARD EV CHARGING STALL - 9' WIDE BY 18' LONG 6 STRIPING COLORS: ACCESSIBLE (INCLUDING EV) STALL: BLUE, EV CHARGING STALL: GREEN, STANDARDSTALLS: WHITE. VERIFY STRIPING COLORS WITH AHJ. 7 6" THICK CONCRETE SLAB UNDER TRASH ENCLOSURE. EXTEND SLAB 6' BEYOND ENCLOSURE. 8 TRASH AND RECYCLING DUMPSTERS PROVIDED BY OTHER. 9 GUTTER AND DOWNSPOUT. DOWNSPOUT TO CONNECT TO STORM SEWER. 10 AREA DRAIN. CONNECT TO STORM SEWER. 11 4' HIGH ORNAMENTAL IRON FENCE 12 3' HIGH ORNAMENTAL IRON FENCE ON RETAINING WALL EXTENDING 1' ABOVE GRADE 13 FROST-PROOF WALL HYDRANT IN KEYED BOX. 14 POST HYDRANT 15 EV CHARGING STATION SERVING TWO NON-ACCESSIBLE STALLS, CENTER CHARGING STATIONBETWEEN STALLS. VERIFY CLEARANCES AND DIMENSIONS WITH MANUFACTURER INSTALLATIONINSTRUCTIONS. 16 EV CHARGING STATION SERVING ONE ACCESSIBLE AND ONE NON-ACCESSIBLE SPACE. CHARGINGSTATION MUST BE ON LEVEL WITH ACCESS AISLE. VERIFY CLEARANCES AND DIMENSIONS WITHMANUFACTURER INSTALLATION INSTRUCTIONS. 17 8' WIDE AISLE FOR VAN ACCESSIBLE PARKING STALL. PROVIDE SIGNAGE AS REQUIRED. CHARGINGSTATION TO BE ON LEVEL WITH ACCESS AISLE. PROVIDE BOLLARDS IN FRONT OF CHARGING STATION.DO NOT OBSTRUCT ACCESS AISLE WITH BOLLARDS, WHEEL STOPS OR SIGNAGE. 18 ACCESSIBLE PARKING SPACE - VAN ACCESSIBLE AND EV CHARGING STATION. 8' WIDE BY 20' LONG.PROVIDE SIGNAGE FOR ACCESSIBLE PARKING STALL AS REQUIRED. PROVIDE SIGNAGE INDICATING VANACCESSIBLE STALL. PROVIDE SIGN THAT READS, "ELECTRIC VEHICLE PARKING PREFERRED" BELOWACCESSIBILITY SIGNS. PROVIDE CONCRETE WHEEL STOP. ANY VEHICLE WITH AN ACCESSIBLE PARKINGPERMIT MUST BE ALLOWED TO PARK IN THIS SPACE. 19 SEMI-ENCLOSED SMOKING SHELTER GREATER THAN 25' FROM WINDOWS, DOORS OR AIR INTAKEVENTS. PROVIDE BENCH AT ADA ACCESSIBLE HEIGHT, ASH RECEPTACLE AND TRASH CAN. SCREENWITH LANDSCAPING WHERE POSSIBLE. 20 ACCESSIBLE CURB RAMP TO MEET ALL ACCESSIBILITY REQUIREMENTS. MAXIMUM SLOPE OF RUN 1:12. 21 EMERGENCY SHUT-OFF FOR FIRE PITS AND GAS GRILLS. ENSURE BUTTON IS MOUNTED WITHIN ADAREACH RANGE AND CLEARLY MARKED. 22 TRELLIS ABOVE 23 SURFACE-MOUNTED UTILITY LIGHT 25 ACCESSIBLE ROUTE. MARK WHERE ROUTE CROSSES VEHICULAR TRAFFIC. 29 STAMPED, COLORED CONCRETE APRON AND COURTYARD 30 CANOPY/BALCONY ABOVE 31 40'x100' WEDDING AREA, GREATER THAN 20' FROM BUILDING WALLS. OWNER TO SECURE EVENT PERMITWITH SPOKANE VALLEY FIRE DEPARTMENT PRIOR TO EVENTS. 32 ALL EQUIPMENT (INCLUDING DRYER VENTS) MUST BE SCREENED WITH LANDSCAPING OR OTHERMEANS. 7 88 1010 10 13 9 14 2TYP. 9 8 13 9 14 2TYP. 8 9 2323 EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV Revision Schedule Number Description Date TV 5 3 D FGE 1 13 15 A-434A 9 7 10 8 4 K 2 6 H J D-141 462 SF OUTDOORKITCHEN 003 TYP OF-711 TYP OF-706 TYP OF-702 TYP OF-708 TYP OF-700 TYP OF-705 TYP OF-708 TYP OF-702 A-4041 A-406 3 TYP OF-701 TYP OF-701 TYP OF-706 TYP OF-703 OF-707 TYP OF-702 TYP OF-702 TYP OF-700 TYP OF-705 2 A-301 204 SF POOL MEP 103 D-121 SC-01 SITE LEGEND DUPLEX OUTLET - GFCI DUPLEX OUTLET - WEATHERPROOF/GFCI COMBINED SMOKE/CARBON MONOXIDE DETECTOR OUTDOOR KITCHEN PENDANT (OF-704) FREEZEPROOF WALL HYDRANT POLE HYDRANT 6" ROUND BOLLARD WP S/CO ACT ACOUSTIC CEILING TILEASALUMINUM STOREFRONTCGCORNER GUARDCONC CONCRETE, UNFINISHEDCPCARPETCPTCARPET TILECSCONCRETE, FINISHEDGWBGYPSUM WALL BOARDFCFIBER CEMENTFRPFIBERGLASS-REINFORCEDPLASTICMR GWB MOISTURE-RESISTANT GYPSUM WALL BOARDPLPLASTIC LAMINATEPTPAINT/POWDER COATQTQUARRY TILERBRUBBER BASERESRESILIENT TILE FLOORSCSTAMPED CONCRETESFSPECIALTY FINISH (KNOCK DOWN)SS ENGINEERED SOLID SURFACESTSTONESTLSTAINLESS STEELSTRUC STRUCTURE ABOVEVCTVINYL COMPOSITE TILEWCVINYL WALL COVERINGWDWOOD-LOOK ALUMINUM SLATS AND BATTENSWPSCREEN WALL NOTE: REFER TO FF&E PACKAGE AND SPECIFICATION BOOK FOR FURNITURE AND FINISH SPECIFICATIONS FINISH LEGEND 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216ENLARGEDCOURTYARD PLANS A-403 FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 0'2' 4'8' SCALE: 1/4" = 1'-0" 1/4" = 1'-0" Reference: 1 / A-010 1COURTYARD PLAN North Side of Lobby KEYNOTES - ENLARGED SITE PLANS 1 CONCRETE WHEEL STOP. PROVIDE AT EACH EV CHARGING/EV READY STALL, ACCESSIBLE STALL ANDSTALL ADJACENT TO AN ACCESSIBLE ROUTE. 2 6" BOLLARD 3 STANDARD STALL - 9' WIDE BY 18' LONG 4 EMERGENCY GENERATOR. SEE ELECTRICAL. PROVIDE DENSE LANDSCAPE SCREENING AT GENERATORENCLOSURE. 5 STANDARD EV CHARGING STALL - 9' WIDE BY 18' LONG 6 STRIPING COLORS: ACCESSIBLE (INCLUDING EV) STALL: BLUE, EV CHARGING STALL: GREEN, STANDARDSTALLS: WHITE. VERIFY STRIPING COLORS WITH AHJ. 7 6" THICK CONCRETE SLAB UNDER TRASH ENCLOSURE. EXTEND SLAB 6' BEYOND ENCLOSURE. 8 TRASH AND RECYCLING DUMPSTERS PROVIDED BY OTHER. 9 GUTTER AND DOWNSPOUT. DOWNSPOUT TO CONNECT TO STORM SEWER. 10 AREA DRAIN. CONNECT TO STORM SEWER. 11 4' HIGH ORNAMENTAL IRON FENCE 12 3' HIGH ORNAMENTAL IRON FENCE ON RETAINING WALL EXTENDING 1' ABOVE GRADE 13 FROST-PROOF WALL HYDRANT IN KEYED BOX. 14 POST HYDRANT 15 EV CHARGING STATION SERVING TWO NON-ACCESSIBLE STALLS, CENTER CHARGING STATIONBETWEEN STALLS. VERIFY CLEARANCES AND DIMENSIONS WITH MANUFACTURER INSTALLATIONINSTRUCTIONS. 16 EV CHARGING STATION SERVING ONE ACCESSIBLE AND ONE NON-ACCESSIBLE SPACE. CHARGINGSTATION MUST BE ON LEVEL WITH ACCESS AISLE. VERIFY CLEARANCES AND DIMENSIONS WITHMANUFACTURER INSTALLATION INSTRUCTIONS. 17 8' WIDE AISLE FOR VAN ACCESSIBLE PARKING STALL. PROVIDE SIGNAGE AS REQUIRED. CHARGINGSTATION TO BE ON LEVEL WITH ACCESS AISLE. PROVIDE BOLLARDS IN FRONT OF CHARGING STATION.DO NOT OBSTRUCT ACCESS AISLE WITH BOLLARDS, WHEEL STOPS OR SIGNAGE. 18 ACCESSIBLE PARKING SPACE - VAN ACCESSIBLE AND EV CHARGING STATION. 8' WIDE BY 20' LONG.PROVIDE SIGNAGE FOR ACCESSIBLE PARKING STALL AS REQUIRED. PROVIDE SIGNAGE INDICATING VANACCESSIBLE STALL. PROVIDE SIGN THAT READS, "ELECTRIC VEHICLE PARKING PREFERRED" BELOWACCESSIBILITY SIGNS. PROVIDE CONCRETE WHEEL STOP. ANY VEHICLE WITH AN ACCESSIBLE PARKINGPERMIT MUST BE ALLOWED TO PARK IN THIS SPACE. 19 SEMI-ENCLOSED SMOKING SHELTER GREATER THAN 25' FROM WINDOWS, DOORS OR AIR INTAKEVENTS. PROVIDE BENCH AT ADA ACCESSIBLE HEIGHT, ASH RECEPTACLE AND TRASH CAN. SCREENWITH LANDSCAPING WHERE POSSIBLE. 20 ACCESSIBLE CURB RAMP TO MEET ALL ACCESSIBILITY REQUIREMENTS. MAXIMUM SLOPE OF RUN 1:12. 21 EMERGENCY SHUT-OFF FOR FIRE PITS AND GAS GRILLS. ENSURE BUTTON IS MOUNTED WITHIN ADAREACH RANGE AND CLEARLY MARKED. 22 TRELLIS ABOVE 23 SURFACE-MOUNTED UTILITY LIGHT 25 ACCESSIBLE ROUTE. MARK WHERE ROUTE CROSSES VEHICULAR TRAFFIC. 29 STAMPED, COLORED CONCRETE APRON AND COURTYARD 30 CANOPY/BALCONY ABOVE 31 40'x100' WEDDING AREA, GREATER THAN 20' FROM BUILDING WALLS. OWNER TO SECURE EVENT PERMITWITH SPOKANE VALLEY FIRE DEPARTMENT PRIOR TO EVENTS. 32 ALL EQUIPMENT (INCLUDING DRYER VENTS) MUST BE SCREENED WITH LANDSCAPING OR OTHERMEANS. 8. CATCH BASINS ARE TO BE PLACED SO AS NOT TO INTERFERE WITH DESIGNATED ACCESSIBLE ROUTES. 7. 10% OF NON-PAVED, NON-COVERED AREA OF PROJECT SITE TO BE LANDSCAPED. 6. INSTALL ACCENT PLANTINGS OF ANNUALS AND PERENNIALS AT MAIN ENTRANCE, BUILDING ENTRY, AND SIGNAGEAREAS, AND BACKYARD. 5. SOD ALL AREAS NOT WITHIN PLANTING BEDS. 4. IRRIGATE ALL LANDSCAPED AREAS WITH AUTOMATIC UNDERGROUND SPRINKLER SYSTEM. 3. BUILDING UPLIGHTING SHALL NOT BE OBSTRUCTED BY LANDSCAPE PLANTINGS. 2. REFER TO HILTON SIGNAGE STANDARDS, BRAND STANDARDS AND HILTON marKIT FOR ADDITIONAL INFORMATIONAND PRECISE SIGNAGE REQUIREMENTS. ELECTRICAL FOR BUILDING SIGNAGE AND MONUMENT SIGNAGE SHALLBE PROVIDED AND CONNECTED BY THE CONTRACTOR. 1. COORDINATE LIGHTING LOCATIONS WITH LANDSCAPE PLANTINGS GENERAL NOTES- SITE 30 31 32 30 3030 25 25 29 29 13 13 13 21 21 21 22 22 EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV Revision Schedule Number Description Date A-40527 1 A-405 TYP OF-702 OF-708 TYP OF-703 K-96 OF-708 TYP OF-702 XS7 XS7 XS7 K-96 22' - 0" 1 A-406 A-4055 A-405 6 4' - 0"4' - 2 1/2"2' - 6"10' - 0"3' - 4 1/4"3' - 0"5' - 6"3' - 0"3' - 4 1/4"0' - 6 1/4"3' - 0"2' - 1" 3' - 3"0' - 7 1/2"11' - 0"11' - 0"6' - 5 1/4"A-4054A-405 3 FRP-01 SS-10 SS-10 K-97 K-97 XS6 SC-01 1 A-405 0' - 9"22' - 0"0' - 9"0' - 9"22' - 0"0' - 9"23' - 6"23' - 6"9' - 1 1/2"3' - 0"3' - 0"TYP OF-704 PC-04 PC-04PC-04WD-1 LINEAR LIGHT FIXTURE, SEE ELECTRICAL SS-10 SS-10 SS-10 SITE LEGEND DUPLEX OUTLET - GFCI DUPLEX OUTLET - WEATHERPROOF/GFCI COMBINED SMOKE/CARBON MONOXIDE DETECTOR OUTDOOR KITCHEN PENDANT (OF-704) FREEZEPROOF WALL HYDRANT POLE HYDRANT 6" ROUND BOLLARD WP S/CO 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216ENLARGED OUTDOORKITCHEN PLANS A-404 FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 0'1' 2'4' SCALE: 1/2" = 1'-0" 1/2" = 1'-0" Reference: 1 / A-403 1OUTDOOR KITCHEN PLAN Room 003 In Courtyard 1/2" = 1'-0"3 OUTDOOR KITCHEN RCP Room 003 In Courtyard 1/2" = 1'-0"2COUNTER CAP PLAN Room 003 In Courtyard KEYNOTES - ENLARGED SITE PLANS 1 CONCRETE WHEEL STOP. PROVIDE AT EACH EV CHARGING/EV READY STALL, ACCESSIBLE STALL ANDSTALL ADJACENT TO AN ACCESSIBLE ROUTE. 2 6" BOLLARD 3 STANDARD STALL - 9' WIDE BY 18' LONG 4 EMERGENCY GENERATOR. SEE ELECTRICAL. PROVIDE DENSE LANDSCAPE SCREENING AT GENERATORENCLOSURE. 5 STANDARD EV CHARGING STALL - 9' WIDE BY 18' LONG 6 STRIPING COLORS: ACCESSIBLE (INCLUDING EV) STALL: BLUE, EV CHARGING STALL: GREEN, STANDARDSTALLS: WHITE. VERIFY STRIPING COLORS WITH AHJ. 7 6" THICK CONCRETE SLAB UNDER TRASH ENCLOSURE. EXTEND SLAB 6' BEYOND ENCLOSURE. 8 TRASH AND RECYCLING DUMPSTERS PROVIDED BY OTHER. 9 GUTTER AND DOWNSPOUT. DOWNSPOUT TO CONNECT TO STORM SEWER. 10 AREA DRAIN. CONNECT TO STORM SEWER. 11 4' HIGH ORNAMENTAL IRON FENCE 12 3' HIGH ORNAMENTAL IRON FENCE ON RETAINING WALL EXTENDING 1' ABOVE GRADE 13 FROST-PROOF WALL HYDRANT IN KEYED BOX. 14 POST HYDRANT 15 EV CHARGING STATION SERVING TWO NON-ACCESSIBLE STALLS, CENTER CHARGING STATIONBETWEEN STALLS. VERIFY CLEARANCES AND DIMENSIONS WITH MANUFACTURER INSTALLATIONINSTRUCTIONS. 16 EV CHARGING STATION SERVING ONE ACCESSIBLE AND ONE NON-ACCESSIBLE SPACE. CHARGINGSTATION MUST BE ON LEVEL WITH ACCESS AISLE. VERIFY CLEARANCES AND DIMENSIONS WITHMANUFACTURER INSTALLATION INSTRUCTIONS. 17 8' WIDE AISLE FOR VAN ACCESSIBLE PARKING STALL. PROVIDE SIGNAGE AS REQUIRED. CHARGINGSTATION TO BE ON LEVEL WITH ACCESS AISLE. PROVIDE BOLLARDS IN FRONT OF CHARGING STATION.DO NOT OBSTRUCT ACCESS AISLE WITH BOLLARDS, WHEEL STOPS OR SIGNAGE. 18 ACCESSIBLE PARKING SPACE - VAN ACCESSIBLE AND EV CHARGING STATION. 8' WIDE BY 20' LONG.PROVIDE SIGNAGE FOR ACCESSIBLE PARKING STALL AS REQUIRED. PROVIDE SIGNAGE INDICATING VANACCESSIBLE STALL. PROVIDE SIGN THAT READS, "ELECTRIC VEHICLE PARKING PREFERRED" BELOWACCESSIBILITY SIGNS. PROVIDE CONCRETE WHEEL STOP. ANY VEHICLE WITH AN ACCESSIBLE PARKINGPERMIT MUST BE ALLOWED TO PARK IN THIS SPACE. 19 SEMI-ENCLOSED SMOKING SHELTER GREATER THAN 25' FROM WINDOWS, DOORS OR AIR INTAKEVENTS. PROVIDE BENCH AT ADA ACCESSIBLE HEIGHT, ASH RECEPTACLE AND TRASH CAN. SCREENWITH LANDSCAPING WHERE POSSIBLE. 20 ACCESSIBLE CURB RAMP TO MEET ALL ACCESSIBILITY REQUIREMENTS. MAXIMUM SLOPE OF RUN 1:12. 21 EMERGENCY SHUT-OFF FOR FIRE PITS AND GAS GRILLS. ENSURE BUTTON IS MOUNTED WITHIN ADAREACH RANGE AND CLEARLY MARKED. 22 TRELLIS ABOVE 23 SURFACE-MOUNTED UTILITY LIGHT 25 ACCESSIBLE ROUTE. MARK WHERE ROUTE CROSSES VEHICULAR TRAFFIC. 29 STAMPED, COLORED CONCRETE APRON AND COURTYARD 30 CANOPY/BALCONY ABOVE 31 40'x100' WEDDING AREA, GREATER THAN 20' FROM BUILDING WALLS. OWNER TO SECURE EVENT PERMITWITH SPOKANE VALLEY FIRE DEPARTMENT PRIOR TO EVENTS. 32 ALL EQUIPMENT (INCLUDING DRYER VENTS) MUST BE SCREENED WITH LANDSCAPING OR OTHERMEANS. 8. CATCH BASINS ARE TO BE PLACED SO AS NOT TO INTERFERE WITH DESIGNATED ACCESSIBLE ROUTES. 7. 10% OF NON-PAVED, NON-COVERED AREA OF PROJECT SITE TO BE LANDSCAPED. 6. INSTALL ACCENT PLANTINGS OF ANNUALS AND PERENNIALS AT MAIN ENTRANCE, BUILDING ENTRY, AND SIGNAGEAREAS, AND BACKYARD. 5. SOD ALL AREAS NOT WITHIN PLANTING BEDS. 4. IRRIGATE ALL LANDSCAPED AREAS WITH AUTOMATIC UNDERGROUND SPRINKLER SYSTEM. 3. BUILDING UPLIGHTING SHALL NOT BE OBSTRUCTED BY LANDSCAPE PLANTINGS. 2. REFER TO HILTON SIGNAGE STANDARDS, BRAND STANDARDS AND HILTON marKIT FOR ADDITIONAL INFORMATIONAND PRECISE SIGNAGE REQUIREMENTS. ELECTRICAL FOR BUILDING SIGNAGE AND MONUMENT SIGNAGE SHALLBE PROVIDED AND CONNECTED BY THE CONTRACTOR. 1. COORDINATE LIGHTING LOCATIONS WITH LANDSCAPE PLANTINGS GENERAL NOTES- SITE EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV Revision Schedule Number Description Date 4' - 9"2' - 10"A-4062 A-4061 OF-704 A-4058 0' - 3"9' - 6"0' - 3"2' - 10"CT-14 FRP-01FRP-01 CT-14 2' - 10"FRP-01 1' - 11 1/4"0' - 4 1/4"3' - 0"3' - 0"2' - 9"2' - 9"3' - 0"3' - 0"3' - 0"7' - 1 3/4"WD-1 WD-1 PC-04 SS-10 XS-F SS-10 SS-10SS-10 K-96 STL STL STL STL STL SS-10 STL STL SS-10 SS-10 ALUMINUM BATTEN TRELLIS STRUCTURAL COLUMN, TYP. WD-1 WD-1 PC-04 SS-10 XS-F PC-04 OF-704 FRP-01 SS-10 XS-F SS-10 STRUCTURAL COLUMN, TYP. STRUCTURAL COLUMN, TYP. TYP OF-704 SS-10SS-10SS-10 K-96 K-96 WD-1 PC-04 WD-1 STLSTL ACT ACOUSTIC CEILING TILEASALUMINUM STOREFRONTCGCORNER GUARDCONC CONCRETE, UNFINISHEDCPCARPETCPTCARPET TILECSCONCRETE, FINISHEDGWBGYPSUM WALL BOARDFCFIBER CEMENTFRPFIBERGLASS-REINFORCEDPLASTICMR GWB MOISTURE-RESISTANT GYPSUM WALL BOARDPLPLASTIC LAMINATEPTPAINT/POWDER COATQTQUARRY TILERBRUBBER BASERESRESILIENT TILE FLOORSCSTAMPED CONCRETESFSPECIALTY FINISH (KNOCK DOWN)SS ENGINEERED SOLID SURFACESTSTONESTLSTAINLESS STEELSTRUC STRUCTURE ABOVEVCTVINYL COMPOSITE TILEWCVINYL WALL COVERINGWDWOOD-LOOK ALUMINUM SLATS AND BATTENSWPSCREEN WALL NOTE: REFER TO FF&E PACKAGE AND SPECIFICATION BOOK FOR FURNITURE AND FINISH SPECIFICATIONS FINISH LEGEND 2"X6" ALUMINUM BATTENSEE KNOTWOOD INSTALLATION INSTRUCTIONS HOLLOW STEEL STRUCTURAL MEMBER. SEE STRUCTURAL. COLUMN COVER TO MATCH WOOD-LOOK FINISH OF BATTENS 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216ENLARGED OUTDOORKITCHEN ELEVATIONS,SECTIONS & DETAILS A-405 FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 0'2' 4'8' SCALE: 1/4" = 1'-0" 1/2" = 1'-0" Reference: 1 / A-404 3OUTDOOR KITCHEN NORTH ELEVATION Room 003 In Courtyard 1/2" = 1'-0" Reference: 1 / A-404 4OUTDOOR KITCHEN WEST ELEVATION Room 003 In Courtyard 1/2" = 1'-0" Reference: 1 / A-404 1OUTDOOR KITCHEN SECTION Room 003 In Courtyard 1/2" = 1'-0" Reference: 1 / A-404 7OUTDOOR ISLAND EAST ELEVATION Room 003 In Courtyard 1/2" = 1'-0" Reference: 1 / A-404 5OUTDOOR ISLAND WEST ELEVATION Room 003 In Courtyard 1/2" = 1'-0" Reference: 1 / A-404 6OUTDOOR ISLAND NORTH ELEVATION Room 003 In Courtyard 1/2" = 1'-0" Reference: 1 / A-404 2OUTDOOR KITCHEN GRILL COUNTER ELEVATION Room 003 In Courtyard 1 1/2" = 1'-0" Reference: 1 / A-405 8 TRELLIS DETAIL 0'4" 8"1' 4" SCALE: 1 1/2" = 1'-0" EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV Revision Schedule Number Description Date 6' - 10"1' - 6"0' - 6 1/2"5' - 9"0' - 6 1/2"0' - 6 1/2"1' - 9"0' - 6 1/2" 2' - 10" 12"X60"LINEAR FIRE PIT 1' - 6"6' - 3"0' - 7"0' - 4"0' - 8"6' - 10" 5' - 9" 1/4" TEMPERED GLASS W/ POLISHED EDGES BOARD FORMED CONCRETE LOCATED EMERGENCY SHUT-OFF BUTTON ON END OF FIRE PIT 1' - 3"0' - 4" 0' - 8" 0' - 7"1' - 8"0' - 7" 2' - 10" 1' - 9" 3' - 6" 1/4" TEMPERED GLASSW/ POLISHED EDGES BOARD FORMED CONCRETE 0' - 4" 0' - 11"1' - 3"0' - 4"0' - 4"1' - 11"0' - 11 1/4" 1' - 9" 7/8"1"1' - 7"1/4" TEMPERED GLASS IN U-CHANNEL SUPPORT COLOR D, REF-??? LINEAR LED LIGHTING BOARD FORMED CONCRETE 1' - 8"2' - 10"0' - 3 1/2"4' - 0" 0' - 2" ℄0' - 3"℄2' - 0"2' - 7"0' - 3"2' - 10"1' - 0" 1' - 6" CERAMIC TILE, CT-14 MARINE GRADE PLYWOOD, TYP MITERED CORNER 2 CM ENGINEERED STONE, SS-10 PURSE HOOK LIGHTING AS SPECIFIED GFCI GUEST CONVENIENCE OUTLET 2 CM ENGINEERED STONE, SS-10 STAINLESS STEEL 0' - 4"0' - 3"MITERED CORNER 2 CM ENGINEERED STONE STAINLESS STEEL THIN BRICK VENEER COLOR C, REF ??? 2 CM SOLID SURFACE 2 CM ENGINEERED STONE, SS-10 MARINE GRADE PLYWOOD,TYP4' - 2 1/2"0' - 6 1/2"4' - 9"1' - 0" 0' - 1"0' - 4" 1" = 1'-0" Reference: 1 / A-403 3 FIREPIT PLAN 1" = 1'-0"4 FIRE PIT SIDE ELEVATION 1" = 1'-0" Reference: 3 / A-406 5 FIRE PIT END ELEVATION 1" = 1'-0" Reference: 3 / A-406 6 FIRE PIT SECTION 1" = 1'-0" Reference: 1 / A-404 1OUTDOOR KITCHEN ISLAND SECTION 1" = 1'-0" Reference: 1 / A-404 2OUTDOOR KITCHEN COUNTER SECTION 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216ENLARGED OUTDOORKITCHEN DETAILS A-406 FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 0'2' 4'8' SCALE: 1/4" = 1'-0" EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV Revision Schedule Number Description Date A-202 1 FGE 11 9 K 3 A-505 10 H J 2 A-301 1 A-505 OP-704OP-704 2 29 5 20 30 2020 393927' - 1 1/2"17' - 7"44' - 0" 30' - 0"12' - 0"24' - 11 1/4"39' - 3"7' - 10"4' - 0"21 22 A-432A 4 5 7 8 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216ENLARGED PORTECOCHERE PLAN A-407 FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 0'2' 4'8' SCALE: 1/4" = 1'-0" 1/4" = 1'-0" Reference: 1 / A-010 1PORTE COCHERE PLAN EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV Revision Schedule Number Description Date MMAATV SD TV A-434A10 A-411B 1 2 3 4 A-411B 6 5 A-423 1 D-G03 7' - 9 3/4"6' - 9 3/4"2' - 1"P1.1 P1.2 GR-307 GR-201 GR-907 GR-307 GR-100 GR-313 GR-ES GR-400GR-906GR-911 GR-310 GR-102 GR-325 GR-908 GR-201 GR-501 D-G02 GR-400 GR-200 GR-506 GR-508 D-G01 6' - 5 3/4"10' - 6 1/4"4' - 0" 14' - 3 3/4" P3.1 XE1/2 3' - 2 1/4"4' - 7 3/4" GR-319 AP-01 GR-500 GR-901 GR-902 6' - 0 1/2" CL-A8' - 0" GR-400 GR-400GR-4102' - 4"2' - 4"3' - 4" 1 7' - 2"5' - 3"1' - 0"A-423 2 1 CL-B8' - 0" CL-B27' - 6" CL-B27' - 6" PLAN ELEV DUPLEX OUTLET QUADPLEX OUTLET GFCI OUTLET CAT6, RJ45 INTERNET OUTLET TELEPHONE OUTLET WALL MOUNTED WIRELESS THERMOSTAT POWER OUTLET WITH USB PORTS CATV OUTLET ELECTRICAL SWITCH FLOOR OUTLET POWER AND SIGNAL LEGEND: POWER SUPPLY CEILING FIXTURE LEGEND: 6" RECESSED CAN DOWNLIGHT DECORATIVE FLUSH MOUNT LIGHT PENDENT TYPE SPRINKLERS SMOKE DETECTOR EXHAUST FAN / GRILLE LINEAR SURFACE MOUNTED CONTINUOUS LED SYSTEM W/ FIXED MOUNTING CLIPS & FROSTED LENS / 3 WATTS PER FOOT, MLV/FWD ELECTRICAL OUTLET HEIGHTS (U.N.O) TYPICAL OUTLET - 15" A.F.F TYPICAL ACCESSIBLE WALL OUTLET - 18" A.F.F BATHROOM VANITY OUTLET - 42" A.F.F TYP. KITCHEN OUTLET - 42" A.F.F ADA KITCHEN OUTLET - 46" A.F.F ADA BATHROOM VANITY OUTLET - 44" A.F.F ELECTRICAL SWITCH HEIGHTS (U.N.O) SWITCH - 44" A.F.F THERMOSTAT REMOTE - 48" A.F.F MAX TO TOP OF SWITCH JUNCTION BOX DOOR BELL HARDWIRED TO DOORBELL LIGHT - MOUNT @ 46" A.F.F TO CENTER OF BUTTON (FOR COMMUNICATIONS FEATURES ROOMS ONLY) SD 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216UNIT PLANS -EFFICIENCY STUDIO A-411 FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 0'1' 2'4' SCALE: 1/2" = 1'-0" 1/2" = 1'-0" Reference: 1 / A-102 1EFFICIENCY STUDIO CONSTRUCTION PLAN Units x05, 307, 407, 507, x08, x27-x29, x31, x33-x34 1/2" = 1'-0"2EFFICIENCY STUDIO REFLECTED CEILING PLAN Units x05, 307, 407, 507, x08, x27-x29, x31, x33-x34 22 2 2 2 2 5 KEYNOTES - UNIT PLANS 1 ALIGN 2 GENERAL CONTRACTOR TO COORDINATE W/ FURNITUREFABRICATOR WHERE NECESSARY TO PROVIDE PROPERBLOCKING IN WALL FOR ITEM KEYNOTED 3 NO FINISHES UNDER THE SHOWER PAN / TUB 4 NO FINISHES UNDER MILLWORK CABINETRY 5 TV AND MOUNT NOT TO PROJECT MORE THAN 4" FROMWALL 6 MOTORIZED BLINDS. PROVIDE JUNCTION BOX BEHINDVALENCE FOR POWER CONNECTION AND PERMANENTLYINSTALLED SWITCH ON WALL TO CONTROL BLINDS. 7 SWITCH CONTROLLING UNDER CABINET LIGHTING ATKITCHEN TO BE GANGED WITH LIGHTING AT ENTRY 8 SWITCH CONTROLLING GARBAGE DISPOSAL-REFER TOHADG FOR ACCESSIBLE ROOM REQ'S. 9 DEDICATED CIRCUIT FOR GARBAGE DISPOSAL 10 MASTER SWITCH 11 DEDICATED CIRCUIT FOR INDUCTION COOKTOP 12 DEDICATED CIRCUIT FOR DISHWASHER 13 DEDICATED CIRCUIT FOR REFRIGERATOR 14 ELECTRIC VANITY MIRROR - HARDWIRE FIXTURE TO WALL-CONTRACTOR TO VERIFY JBOX TYPE TO ENSURE PROPERINSTALLATION AND BACKING FOR ITEM KEYNOTED 15 DOORBELL AND DOORBELL ON/OFF SWITCH(COMMUNICATION FEATURES ROOMS ONLY)SIGNAGE ASREQ'D. 16 PLACE TV OUTLETS AND CONNECTIONS ON WALL OUTSIDEAREA OF BRACKET AND CONCEALED FROM VIEW BY TV 17 DEDICATED CIRCUIT FOR WASHER/DRYER. DIRECT VENTTO EXTERIOR FURNISHING SCHEDULE GUESTROOM FURNISHINGS GR-100 CHAIR - LOUNGE CHAIR WITH OTTOMAN GR-102 CHAIR - COUNTER HEIGHT DESK CHAIR GR-200 SCONCE - PIN-UP GR-201 SCONCE - NIGHTSTAND GR-202 LAMP - DESK GR-307 NIGHTSTAND - SMALL GR-310 DESK - EFFICIENCY GR-313 TABLE - ROUND SIDE TABLE GR-319 CLOSET - EFFICIENCY SUITE GR-325 VANITY - EFFICIENCY SUITE GR-326 VANITY - STUDIO AND 1-BEDROOM SUITES GR-400 STATIC DRAPARY PANELS GR-403 ROLLER SHADE - GUESTROOMS (MANUAL,SHEER/BLACK-OUT, 8' W) GR-410 VALENCE FOR 5' WINDOW GR-500 ART GR-501 ART GR-505 WALL HOOK GR-506 MIRROR - GUESTROOM FULL LENGTH GR-508 MIRROR - GUESTROOM VANITY GR-802 KITCHENETTE - EFFICIENCY SUITE GR-900 GUESTROOM REFRIGERATOR GR-901 GUESTROOM DISHWASHER GR-902 GUESTROOM COOKTOP - 2 BURNER GR-904 GARBAGE DISPOSAL 1/3HP GR-905 MICROWAVE- WITH RECIRCULATING HOOD GR-906GR-911 TELEVISION & TELEVISION MOUNT GR-907 CLOCK/RADIO GR-908 TELEPHONE - GUESTROOM GR-ES BED - EFFICIENCY (GR-300, 303, 600) GR-KS BED - KING (GR-301, 303, 600) PLUMBING/MECHANICAL FIXTURES PF-01 TOILET - GUESTROOM PF-03 SHOWER BASE - 60" X 36" WITH LINEARDRAIN PF-07 LAVATORY - UNDERMOUNT, 20" X 14" PF-11 SHOWER HEAD - 2 IN 1 PF-13 SHOWER/TUB VALVE & CONTROL PF-15 FAUCET - LAVATORY PF-40 SINK - KITCHENETTE PF-41 FAUCET - KITCHENETTE TOILET ACCESSORIES HD-01 DUAL TOILET PAPER HOLDER HD-04 WALL-MOUNTED ROBE HOOK HD-05.2 SLIDING SHOWER DOOR HD-08 18" GRAB BAR HD-16 BULK AMENITY DISPENSER ATSHOWERS/TUBS HD-18 FOOT LEDGE FOR SHOWER HD-18.1 SOAP SHELF HD-21 BULK AMENITY DISPENSER AT LAVATORIES EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV Revision Schedule Number Description Date TV TV CPT-10 SF-01 WC-01 WC-01 WC-01 WC-01WC-01 WC-01 CPT-01 CT-01 RES-01 CPT-01 1 A-510 Sim 2 A-510 Sim 7 A-510 Sim 9 A-510 Sim 3 A-710 A-434A10 A-411B 1 2 3 4 A-411B 6 5 A-423 1 PLAN ELEV DUPLEX OUTLET QUADPLEX OUTLET GFCI OUTLET CAT6, RJ45 INTERNET OUTLET TELEPHONE OUTLET WALL MOUNTED WIRELESS THERMOSTAT POWER OUTLET WITH USB PORTS CATV OUTLET ELECTRICAL SWITCH FLOOR OUTLET POWER AND SIGNAL LEGEND: POWER SUPPLY CEILING FIXTURE LEGEND: 6" RECESSED CAN DOWNLIGHT DECORATIVE FLUSH MOUNT LIGHT PENDENT TYPE SPRINKLERS SMOKE DETECTOR EXHAUST FAN / GRILLE LINEAR SURFACE MOUNTED CONTINUOUS LED SYSTEM W/ FIXED MOUNTING CLIPS & FROSTED LENS / 3 WATTS PER FOOT, MLV/FWD ELECTRICAL OUTLET HEIGHTS (U.N.O) TYPICAL OUTLET - 15" A.F.F TYPICAL ACCESSIBLE WALL OUTLET - 18" A.F.F BATHROOM VANITY OUTLET - 42" A.F.F TYP. KITCHEN OUTLET - 42" A.F.F ADA KITCHEN OUTLET - 46" A.F.F ADA BATHROOM VANITY OUTLET - 44" A.F.F ELECTRICAL SWITCH HEIGHTS (U.N.O) SWITCH - 44" A.F.F THERMOSTAT REMOTE - 48" A.F.F MAX TO TOP OF SWITCH JUNCTION BOX DOOR BELL HARDWIRED TO DOORBELL LIGHT - MOUNT @ 46" A.F.F TO CENTER OF BUTTON (FOR COMMUNICATIONS FEATURES ROOMS ONLY) SD 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216UNIT PLANS -EFFICIENCY STUDIO -ELEC, DATA & FLOORFINISH PLAN A-411A FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 1/2" = 1'-0"2EFFICIENCY STUDIO FLOOR & WALL FINISH PLAN Units x05, 307, 407, 507, x08, x27-x29, x31, x33-x34 1/2" = 1'-0"1EFFICIENCY STUDIO ELECTRICAL & DATA PLAN Units x05, 307, 407, 507, x08, x27-x29, x31, x33-x34 0'1' 2'4' SCALE: 1/2" = 1'-0" 15 12 8 7 9 10 11 13 14 3 KEYNOTES - UNIT PLANS 1 ALIGN 2 GENERAL CONTRACTOR TO COORDINATE W/ FURNITUREFABRICATOR WHERE NECESSARY TO PROVIDE PROPERBLOCKING IN WALL FOR ITEM KEYNOTED 3 NO FINISHES UNDER THE SHOWER PAN / TUB 4 NO FINISHES UNDER MILLWORK CABINETRY 5 TV AND MOUNT NOT TO PROJECT MORE THAN 4" FROMWALL 6 MOTORIZED BLINDS. PROVIDE JUNCTION BOX BEHINDVALENCE FOR POWER CONNECTION AND PERMANENTLYINSTALLED SWITCH ON WALL TO CONTROL BLINDS. 7 SWITCH CONTROLLING UNDER CABINET LIGHTING ATKITCHEN TO BE GANGED WITH LIGHTING AT ENTRY 8 SWITCH CONTROLLING GARBAGE DISPOSAL-REFER TOHADG FOR ACCESSIBLE ROOM REQ'S. 9 DEDICATED CIRCUIT FOR GARBAGE DISPOSAL 10 MASTER SWITCH 11 DEDICATED CIRCUIT FOR INDUCTION COOKTOP 12 DEDICATED CIRCUIT FOR DISHWASHER 13 DEDICATED CIRCUIT FOR REFRIGERATOR 14 ELECTRIC VANITY MIRROR - HARDWIRE FIXTURE TO WALL-CONTRACTOR TO VERIFY JBOX TYPE TO ENSURE PROPERINSTALLATION AND BACKING FOR ITEM KEYNOTED 15 DOORBELL AND DOORBELL ON/OFF SWITCH(COMMUNICATION FEATURES ROOMS ONLY)SIGNAGE ASREQ'D. 16 PLACE TV OUTLETS AND CONNECTIONS ON WALL OUTSIDEAREA OF BRACKET AND CONCEALED FROM VIEW BY TV 17 DEDICATED CIRCUIT FOR WASHER/DRYER. DIRECT VENTTO EXTERIOR FURNISHING SCHEDULE GUESTROOM FURNISHINGS GR-100 CHAIR - LOUNGE CHAIR WITH OTTOMAN GR-102 CHAIR - COUNTER HEIGHT DESK CHAIR GR-200 SCONCE - PIN-UP GR-201 SCONCE - NIGHTSTAND GR-202 LAMP - DESK GR-307 NIGHTSTAND - SMALL GR-310 DESK - EFFICIENCY GR-313 TABLE - ROUND SIDE TABLE GR-319 CLOSET - EFFICIENCY SUITE GR-325 VANITY - EFFICIENCY SUITE GR-400 STATIC DRAPARY PANELS GR-500 ART GR-501 ART GR-506 MIRROR - GUESTROOM FULL LENGTH GR-508 MIRROR - GUESTROOM VANITY GR-900 GUESTROOM REFRIGERATOR GR-901 GUESTROOM DISHWASHER GR-902 GUESTROOM COOKTOP - 2 BURNER GR-904 GARBAGE DISPOSAL 1/3HP GR-906GR-911 TELEVISION & TELEVISION MOUNT GR-907 CLOCK/RADIO GR-908 TELEPHONE - GUESTROOM GR-ES BED - EFFICIENCY (GR-300, 303, 600) PLUMBING/MECHANICAL FIXTURES PF-01 TOILET - GUESTROOM PF-03 SHOWER BASE - 60" X 36" WITH LINEARDRAIN PF-07 LAVATORY - UNDERMOUNT, 20" X 14" PF-11 SHOWER HEAD - 2 IN 1 PF-13 SHOWER/TUB VALVE & CONTROL PF-15 FAUCET - LAVATORY PF-40 SINK - KITCHENETTE PF-41 FAUCET - KITCHENETTE TOILET ACCESSORIES HD-01 DUAL TOILET PAPER HOLDER HD-05.2 SLIDING SHOWER DOOR HD-08 18" GRAB BAR HD-16 BULK AMENITY DISPENSER ATSHOWERS/TUBS HD-18 FOOT LEDGE FOR SHOWER HD-18.1 SOAP SHELF HD-21 BULK AMENITY DISPENSER AT LAVATORIES EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV Revision Schedule Number Description Date TV WC-01 RB-01 WD-01 WD-01 SS-01 D-G01 PT-11PL-01 0' - 8" 2' - 10 3/4" WC-01WC-01 1' - 10" GR-505 0' - 6"1' - 5" RB-01 WC-01 5' - 1 1/2"5' - 0"3 A-710 3' - 10"SS-01 WC-01 WC-01 2' - 4 3/4"WC-01 6' - 2"5' - 2"4' - 3 1/4"5' - 1"RB-01 WD-01 WD-01 WD-01 WC-01 D-G02 AP-01 GR-410 GR-403 PT-03PL-02 WC-01 RB-01 WC-01 2' - 9 3/4" SF-01 RB-01 16 A-510 Sim GR-410 GR-403 GR-400 W-H PLAN ELEV DUPLEX OUTLET QUADPLEX OUTLET GFCI OUTLET CAT6, RJ45 INTERNET OUTLET TELEPHONE OUTLET WALL MOUNTED WIRELESS THERMOSTAT POWER OUTLET WITH USB PORTS CATV OUTLET ELECTRICAL SWITCH FLOOR OUTLET POWER AND SIGNAL LEGEND: POWER SUPPLY CEILING FIXTURE LEGEND: 6" RECESSED CAN DOWNLIGHT DECORATIVE FLUSH MOUNT LIGHT PENDENT TYPE SPRINKLERS SMOKE DETECTOR EXHAUST FAN / GRILLE LINEAR SURFACE MOUNTED CONTINUOUS LED SYSTEM W/ FIXED MOUNTING CLIPS & FROSTED LENS / 3 WATTS PER FOOT, MLV/FWD ELECTRICAL OUTLET HEIGHTS (U.N.O) TYPICAL OUTLET - 15" A.F.F TYPICAL ACCESSIBLE WALL OUTLET - 18" A.F.F BATHROOM VANITY OUTLET - 42" A.F.F TYP. KITCHEN OUTLET - 42" A.F.F ADA KITCHEN OUTLET - 46" A.F.F ADA BATHROOM VANITY OUTLET - 44" A.F.F ELECTRICAL SWITCH HEIGHTS (U.N.O) SWITCH - 44" A.F.F THERMOSTAT REMOTE - 48" A.F.F MAX TO TOP OF SWITCH JUNCTION BOX DOOR BELL HARDWIRED TO DOORBELL LIGHT - MOUNT @ 46" A.F.F TO CENTER OF BUTTON (FOR COMMUNICATIONS FEATURES ROOMS ONLY) SD 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216UNIT INT. ELEVATIONS -EFFICIENCY STUDIO A-411B FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 1/2" = 1'-0" Reference: 1 / A-411 1EFFICIENCY STUDIO ELEVATION A Units x05, 307, 407, 507, x08, x27-x29, x31, x33-x34 1/2" = 1'-0" Reference: 1 / A-411 2EFFICIENCY STUDIO ELEVATION B Units x05, 307, 407, 507, x08, x27-x29, x31, x33-x34 1/2" = 1'-0" Reference: 1 / A-411 3EFFICIENCY STUDIO ELEVATION C Units x05, 307, 407, 507, x08, x27-x29, x31, x33-x34 1/2" = 1'-0" Reference: 1 / A-411 4EFFICIENCY STUDIO ELEVATION D Units x05, 307, 407, 507, x08, x27-x29, x31, x33-x34 1/2" = 1'-0" Reference: 1 / A-411 5EFFICIENCY STUDIO ELEVATION A2 Units x05, 307, 407, 507, x08, x27-x29, x31, x33-x34 1/2" = 1'-0" Reference: 1 / A-411 6EFFICIENCY STUDIO ELEVATION C2 Units x05, 307, 407, 507, x08, x27-x29, x31, x33-x34 FFL FFL FFL 0'1' 2'4' SCALE: 1/2" = 1'-0" KEYNOTES - UNIT PLANS 1 ALIGN 2 GENERAL CONTRACTOR TO COORDINATE W/ FURNITUREFABRICATOR WHERE NECESSARY TO PROVIDE PROPERBLOCKING IN WALL FOR ITEM KEYNOTED 3 NO FINISHES UNDER THE SHOWER PAN / TUB 4 NO FINISHES UNDER MILLWORK CABINETRY 5 TV AND MOUNT NOT TO PROJECT MORE THAN 4" FROMWALL 6 MOTORIZED BLINDS. PROVIDE JUNCTION BOX BEHINDVALENCE FOR POWER CONNECTION AND PERMANENTLYINSTALLED SWITCH ON WALL TO CONTROL BLINDS. 7 SWITCH CONTROLLING UNDER CABINET LIGHTING ATKITCHEN TO BE GANGED WITH LIGHTING AT ENTRY 8 SWITCH CONTROLLING GARBAGE DISPOSAL-REFER TOHADG FOR ACCESSIBLE ROOM REQ'S. 9 DEDICATED CIRCUIT FOR GARBAGE DISPOSAL 10 MASTER SWITCH 11 DEDICATED CIRCUIT FOR INDUCTION COOKTOP 12 DEDICATED CIRCUIT FOR DISHWASHER 13 DEDICATED CIRCUIT FOR REFRIGERATOR 14 ELECTRIC VANITY MIRROR - HARDWIRE FIXTURE TO WALL-CONTRACTOR TO VERIFY JBOX TYPE TO ENSURE PROPERINSTALLATION AND BACKING FOR ITEM KEYNOTED 15 DOORBELL AND DOORBELL ON/OFF SWITCH(COMMUNICATION FEATURES ROOMS ONLY)SIGNAGE ASREQ'D. 16 PLACE TV OUTLETS AND CONNECTIONS ON WALL OUTSIDEAREA OF BRACKET AND CONCEALED FROM VIEW BY TV 17 DEDICATED CIRCUIT FOR WASHER/DRYER. DIRECT VENTTO EXTERIOR FURNISHING SCHEDULE GUESTROOM FURNISHINGS GR-100 CHAIR - LOUNGE CHAIR WITH OTTOMAN GR-102 CHAIR - COUNTER HEIGHT DESK CHAIR GR-200 SCONCE - PIN-UP GR-201 SCONCE - NIGHTSTAND GR-202 LAMP - DESK GR-307 NIGHTSTAND - SMALL GR-308 NIGHTSTAND - REGULAR GR-310 DESK - EFFICIENCY GR-313 TABLE - ROUND SIDE TABLE GR-319 CLOSET - EFFICIENCY SUITE GR-325 VANITY - EFFICIENCY SUITE GR-326 VANITY - STUDIO AND 1-BEDROOM SUITES GR-400 STATIC DRAPARY PANELS GR-403 ROLLER SHADE - GUESTROOMS (MANUAL,SHEER/BLACK-OUT, 8' W) GR-410 VALENCE FOR 5' WINDOW GR-500 ART GR-501 ART GR-505 WALL HOOK GR-506 MIRROR - GUESTROOM FULL LENGTH GR-508 MIRROR - GUESTROOM VANITY GR-802 KITCHENETTE - EFFICIENCY SUITE GR-900 GUESTROOM REFRIGERATOR GR-901 GUESTROOM DISHWASHER GR-902 GUESTROOM COOKTOP - 2 BURNER GR-904 GARBAGE DISPOSAL 1/3HP GR-905 MICROWAVE- WITH RECIRCULATING HOOD GR-906GR-911 TELEVISION & TELEVISION MOUNT GR-907 CLOCK/RADIO GR-908 TELEPHONE - GUESTROOM GR-ES BED - EFFICIENCY (GR-300, 303, 600) GR-KS BED - KING (GR-301, 303, 600) PLUMBING/MECHANICAL FIXTURES PF-01 TOILET - GUESTROOM PF-03 SHOWER BASE - 60" X 36" WITH LINEARDRAIN PF-07 LAVATORY - UNDERMOUNT, 20" X 14" PF-11 SHOWER HEAD - 2 IN 1 PF-13 SHOWER/TUB VALVE & CONTROL PF-15 FAUCET - LAVATORY PF-40 SINK - KITCHENETTE PF-41 FAUCET - KITCHENETTE TOILET ACCESSORIES HD-01 DUAL TOILET PAPER HOLDER HD-04 WALL-MOUNTED ROBE HOOK HD-05.2 SLIDING SHOWER DOOR HD-08 18" GRAB BAR HD-16 BULK AMENITY DISPENSER ATSHOWERS/TUBS HD-18 FOOT LEDGE FOR SHOWER HD-18.1 SOAP SHELF HD-21 BULK AMENITY DISPENSER AT LAVATORIES EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV Revision Schedule Number Description Date MATVSD TVA-412B2 1 4 3 XE1/2W-H D-G03A D-G01A 12' - 5 1/2"15' - 0 1/4"3' - 4 1/4" 7' - 6 3/4" 2' - 0"5' - 1 3/4"2' - 0"7' - 2 1/4" GR-320 GR-308 GR-201 GR-KM GR-308 GR-201 GR-104 GR-311 GR-101 P3.1 GR-327 GR-507 GR-901 GR-902 GR-508 GR-906GR-911 GR-501GR-501 GR-900 14' - 10 1/2" A-4241 CL-B8' - 0" CL-B27' - 6"5' - 10"1' - 0"7' - 4" 3' - 2"3' - 9"1' - 10"1' - 10"3' - 8"1 1 A-424 3Sim PLAN ELEV DUPLEX OUTLET QUADPLEX OUTLET GFCI OUTLET CAT6, RJ45 INTERNET OUTLET TELEPHONE OUTLET WALL MOUNTED WIRELESS THERMOSTAT POWER OUTLET WITH USB PORTS CATV OUTLET ELECTRICAL SWITCH FLOOR OUTLET POWER AND SIGNAL LEGEND: POWER SUPPLY CEILING FIXTURE LEGEND: 6" RECESSED CAN DOWNLIGHT DECORATIVE FLUSH MOUNT LIGHT PENDENT TYPE SPRINKLERS SMOKE DETECTOR EXHAUST FAN / GRILLE LINEAR SURFACE MOUNTED CONTINUOUS LED SYSTEM W/ FIXED MOUNTING CLIPS & FROSTED LENS / 3 WATTS PER FOOT, MLV/FWD ELECTRICAL OUTLET HEIGHTS (U.N.O) TYPICAL OUTLET - 15" A.F.F TYPICAL ACCESSIBLE WALL OUTLET - 18" A.F.F BATHROOM VANITY OUTLET - 42" A.F.F TYP. KITCHEN OUTLET - 42" A.F.F ADA KITCHEN OUTLET - 46" A.F.F ADA BATHROOM VANITY OUTLET - 44" A.F.F ELECTRICAL SWITCH HEIGHTS (U.N.O) SWITCH - 44" A.F.F THERMOSTAT REMOTE - 48" A.F.F MAX TO TOP OF SWITCH JUNCTION BOX DOOR BELL HARDWIRED TO DOORBELL LIGHT - MOUNT @ 46" A.F.F TO CENTER OF BUTTON (FOR COMMUNICATIONS FEATURES ROOMS ONLY) SD 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216UNIT PLAN -EFFICIENCY STUDIOADA MOBILITY A-412 FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 0'1' 2'4' SCALE: 1/2" = 1'-0" 1/2" = 1'-0" Reference: 1 / A-104 1EFFICIENCY ADA UNIT CONSTRUCTION PLAN Units 403 (Roll-In), 503 (Tub) 22 2 2 2 5 2 13 1/2" = 1'-0"2EFFICIENCY ADA UNIT REFLECTED CEILING PLAN Units 403 (Roll-In), 503 (Tub) KEYNOTES - UNIT PLANS 1 ALIGN 2 GENERAL CONTRACTOR TO COORDINATE W/ FURNITUREFABRICATOR WHERE NECESSARY TO PROVIDE PROPERBLOCKING IN WALL FOR ITEM KEYNOTED 3 NO FINISHES UNDER THE SHOWER PAN / TUB 4 NO FINISHES UNDER MILLWORK CABINETRY 5 TV AND MOUNT NOT TO PROJECT MORE THAN 4" FROMWALL 6 MOTORIZED BLINDS. PROVIDE JUNCTION BOX BEHINDVALENCE FOR POWER CONNECTION AND PERMANENTLYINSTALLED SWITCH ON WALL TO CONTROL BLINDS. 7 SWITCH CONTROLLING UNDER CABINET LIGHTING ATKITCHEN TO BE GANGED WITH LIGHTING AT ENTRY 8 SWITCH CONTROLLING GARBAGE DISPOSAL-REFER TOHADG FOR ACCESSIBLE ROOM REQ'S. 9 DEDICATED CIRCUIT FOR GARBAGE DISPOSAL 10 MASTER SWITCH 11 DEDICATED CIRCUIT FOR INDUCTION COOKTOP 12 DEDICATED CIRCUIT FOR DISHWASHER 13 DEDICATED CIRCUIT FOR REFRIGERATOR 14 ELECTRIC VANITY MIRROR - HARDWIRE FIXTURE TO WALL-CONTRACTOR TO VERIFY JBOX TYPE TO ENSURE PROPERINSTALLATION AND BACKING FOR ITEM KEYNOTED 15 DOORBELL AND DOORBELL ON/OFF SWITCH(COMMUNICATION FEATURES ROOMS ONLY)SIGNAGE ASREQ'D. 16 PLACE TV OUTLETS AND CONNECTIONS ON WALL OUTSIDEAREA OF BRACKET AND CONCEALED FROM VIEW BY TV 17 DEDICATED CIRCUIT FOR WASHER/DRYER. DIRECT VENTTO EXTERIOR FURNISHING SCHEDULE GUESTROOM FURNISHINGS GR-101 CHAIR - LOUNGE CHAIR IN STUIDOS GR-104 CHAIR - ADA DESK CHAIR GR-201 SCONCE - NIGHTSTAND GR-308 NIGHTSTAND - REGULAR GR-311 DESK - ACCESSIBLE EFFICIENCY GR-320 CLOSET - ACCESSIBLE EFFICIENCY SUITE GR-327 VANITY - ACCESSIBLE SUITES GR-328 BATH CADDY - ACCESSIBLE SUITES GR-400 STATIC DRAPARY PANELS GR-403 ROLLER SHADE - GUESTROOMS (MANUAL,SHEER/BLACK-OUT, 8' W) GR-410 VALENCE FOR 5' WINDOW GR-501 ART GR-506 MIRROR - GUESTROOM FULL LENGTH GR-507 MIRROR - ADA VANITY GR-508 MIRROR - GUESTROOM VANITY GR-900 GUESTROOM REFRIGERATOR GR-901 GUESTROOM DISHWASHER GR-902 GUESTROOM COOKTOP - 2 BURNER GR-906GR-911 TELEVISION & TELEVISION MOUNT GR-907 CLOCK/RADIO GR-908 TELEPHONE - GUESTROOM GR-912 RECIRCULATING HOOD GR-913 COUNTERTOP MICROWAVE GR-KM BED - KING MOBILITY (GR-301, 304, 600, 602) PLUMBING/MECHANICAL FIXTURES PF-01 TOILET - GUESTROOM PF-04 SHOWER BASE - 60" X 36" ADA ROLL-INSHOWER WITH EDGE TRENCH DRAIN PF-07 LAVATORY - UNDERMOUNT, 20" X 14" PF-10 SHOWER HEAD - HIGH PF-12 SHOWER HEAD - HAND HELD ON SLIDE BAR PF-13 SHOWER/TUB VALVE & CONTROL PF-15 FAUCET - LAVATORY PF-42 SINK - ADA KITCHENETTE TOILET ACCESSORIES HD-01 DUAL TOILET PAPER HOLDER HD-04 WALL-MOUNTED ROBE HOOK HD-04.1 TOWEL BAR HD-05 CURVED CURTAIN ROD AND SHOWERCURTAIN HD-08 18" GRAB BAR HD-09 24" GRAB BAR HD-10 42" GRAB BAR AT ADA BATHTUB HD-11 36" GRAB BAR HD-11.1 42" GRAB BAR HD-14 ROLL-IN SHOWER SEAT HD-16 BULK AMENITY DISPENSER ATSHOWERS/TUBS HD-18.1 SOAP SHELF HD-20 12" GRAB BAR HD-21 BULK AMENITY DISPENSER AT LAVATORIES EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV Revision Schedule Number Description Date TTVTVTVA-412B2 1 4 3 SF-01 WC-01WC-01 WC-01 WC-01 WC-01 13' - 0 3/4"FULL TILE FULL TILEFULL TILEFULL TILE CT-01 RES-01 CPT-01 CPT-10 6 A-510 Sim 9 A-510 Sim 7 A-510 Sim 1 A-510 Sim PLAN ELEV DUPLEX OUTLET QUADPLEX OUTLET GFCI OUTLET CAT6, RJ45 INTERNET OUTLET TELEPHONE OUTLET WALL MOUNTED WIRELESS THERMOSTAT POWER OUTLET WITH USB PORTS CATV OUTLET ELECTRICAL SWITCH FLOOR OUTLET POWER AND SIGNAL LEGEND: POWER SUPPLY CEILING FIXTURE LEGEND: 6" RECESSED CAN DOWNLIGHT DECORATIVE FLUSH MOUNT LIGHT PENDENT TYPE SPRINKLERS SMOKE DETECTOR EXHAUST FAN / GRILLE LINEAR SURFACE MOUNTED CONTINUOUS LED SYSTEM W/ FIXED MOUNTING CLIPS & FROSTED LENS / 3 WATTS PER FOOT, MLV/FWD ELECTRICAL OUTLET HEIGHTS (U.N.O) TYPICAL OUTLET - 15" A.F.F TYPICAL ACCESSIBLE WALL OUTLET - 18" A.F.F BATHROOM VANITY OUTLET - 42" A.F.F TYP. KITCHEN OUTLET - 42" A.F.F ADA KITCHEN OUTLET - 46" A.F.F ADA BATHROOM VANITY OUTLET - 44" A.F.F ELECTRICAL SWITCH HEIGHTS (U.N.O) SWITCH - 44" A.F.F THERMOSTAT REMOTE - 48" A.F.F MAX TO TOP OF SWITCH JUNCTION BOX DOOR BELL HARDWIRED TO DOORBELL LIGHT - MOUNT @ 46" A.F.F TO CENTER OF BUTTON (FOR COMMUNICATIONS FEATURES ROOMS ONLY) SD 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216UNIT PLAN -EFFICIENCY STUDIOADA MOBILITY - ELEC,DATA & FLOOR FINISHPLANA-412A FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 1/2" = 1'-0"3EFFICIENCY ADA UNIT ELECTRICAL AND DATA PLAN Units 403 (Roll-In), 503 (Tub) 1/2" = 1'-0"1EFFICIENCY ADA UNIT FLOOR AND WALL FINISH PLAN Units 403 (Roll-In), 503 (Tub) 0'1' 2'4' SCALE: 1/2" = 1'-0" 15 7 10 12 8 9 11 13 14 3 4 16 KEYNOTES - UNIT PLANS 1 ALIGN 2 GENERAL CONTRACTOR TO COORDINATE W/ FURNITUREFABRICATOR WHERE NECESSARY TO PROVIDE PROPERBLOCKING IN WALL FOR ITEM KEYNOTED 3 NO FINISHES UNDER THE SHOWER PAN / TUB 4 NO FINISHES UNDER MILLWORK CABINETRY 5 TV AND MOUNT NOT TO PROJECT MORE THAN 4" FROMWALL 6 MOTORIZED BLINDS. PROVIDE JUNCTION BOX BEHINDVALENCE FOR POWER CONNECTION AND PERMANENTLYINSTALLED SWITCH ON WALL TO CONTROL BLINDS. 7 SWITCH CONTROLLING UNDER CABINET LIGHTING ATKITCHEN TO BE GANGED WITH LIGHTING AT ENTRY 8 SWITCH CONTROLLING GARBAGE DISPOSAL-REFER TOHADG FOR ACCESSIBLE ROOM REQ'S. 9 DEDICATED CIRCUIT FOR GARBAGE DISPOSAL 10 MASTER SWITCH 11 DEDICATED CIRCUIT FOR INDUCTION COOKTOP 12 DEDICATED CIRCUIT FOR DISHWASHER 13 DEDICATED CIRCUIT FOR REFRIGERATOR 14 ELECTRIC VANITY MIRROR - HARDWIRE FIXTURE TO WALL-CONTRACTOR TO VERIFY JBOX TYPE TO ENSURE PROPERINSTALLATION AND BACKING FOR ITEM KEYNOTED 15 DOORBELL AND DOORBELL ON/OFF SWITCH(COMMUNICATION FEATURES ROOMS ONLY)SIGNAGE ASREQ'D. 16 PLACE TV OUTLETS AND CONNECTIONS ON WALL OUTSIDEAREA OF BRACKET AND CONCEALED FROM VIEW BY TV 17 DEDICATED CIRCUIT FOR WASHER/DRYER. DIRECT VENTTO EXTERIOR FURNISHING SCHEDULE GUESTROOM FURNISHINGS GR-101 CHAIR - LOUNGE CHAIR IN STUIDOS GR-104 CHAIR - ADA DESK CHAIR GR-201 SCONCE - NIGHTSTAND GR-308 NIGHTSTAND - REGULAR GR-311 DESK - ACCESSIBLE EFFICIENCY GR-320 CLOSET - ACCESSIBLE EFFICIENCY SUITE GR-327 VANITY - ACCESSIBLE SUITES GR-328 BATH CADDY - ACCESSIBLE SUITES GR-400 STATIC DRAPARY PANELS GR-501 ART GR-507 MIRROR - ADA VANITY GR-508 MIRROR - GUESTROOM VANITY GR-900 GUESTROOM REFRIGERATOR GR-901 GUESTROOM DISHWASHER GR-902 GUESTROOM COOKTOP - 2 BURNER GR-906GR-911 TELEVISION & TELEVISION MOUNT GR-907 CLOCK/RADIO GR-908 TELEPHONE - GUESTROOM GR-913 COUNTERTOP MICROWAVE GR-KM BED - KING MOBILITY (GR-301, 304, 600, 602) PLUMBING/MECHANICAL FIXTURES PF-01 TOILET - GUESTROOM PF-04 SHOWER BASE - 60" X 36" ADA ROLL-INSHOWER WITH EDGE TRENCH DRAIN PF-07 LAVATORY - UNDERMOUNT, 20" X 14" PF-12 SHOWER HEAD - HAND HELD ON SLIDE BAR PF-13 SHOWER/TUB VALVE & CONTROL PF-15 FAUCET - LAVATORY PF-42 SINK - ADA KITCHENETTE TOILET ACCESSORIES HD-01 DUAL TOILET PAPER HOLDER HD-04 WALL-MOUNTED ROBE HOOK HD-04.1 TOWEL BAR HD-08 18" GRAB BAR HD-09 24" GRAB BAR HD-11 36" GRAB BAR HD-11.1 42" GRAB BAR HD-14 ROLL-IN SHOWER SEAT HD-16 BULK AMENITY DISPENSER ATSHOWERS/TUBS HD-18.1 SOAP SHELF HD-21 BULK AMENITY DISPENSER AT LAVATORIES EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV Revision Schedule Number Description Date TV WC-01 RB-01RB-01 WC-01 D-G01A PT-11PL-01 4' - 10 1/2"4' - 2"5' - 1"PL-02PT-03 WC-01 RB-01 WD-01 WD-01 WC-01 GR-901 GR-900 GR-902 AP-01 D-G02A GR-410 GR-912 6 1' - 10"3' - 11 1/4"5' - 0"W-H SF-01 RB-01 GR-410 16 A-510 Sim GR-405 GR-400 GR-501 GR-505 D-G03A 1' - 5" 0' - 8"2' - 4 1/4" RB-01 WC-01 WC-01 PT-03 PL-02 5' - 0"0' - 6"3' - 4"2' - 1"EQEQ2' - 3 1/4" GR-410 PLAN ELEV DUPLEX OUTLET QUADPLEX OUTLET GFCI OUTLET CAT6, RJ45 INTERNET OUTLET TELEPHONE OUTLET WALL MOUNTED WIRELESS THERMOSTAT POWER OUTLET WITH USB PORTS CATV OUTLET ELECTRICAL SWITCH FLOOR OUTLET POWER AND SIGNAL LEGEND: POWER SUPPLY CEILING FIXTURE LEGEND: 6" RECESSED CAN DOWNLIGHT DECORATIVE FLUSH MOUNT LIGHT PENDENT TYPE SPRINKLERS SMOKE DETECTOR EXHAUST FAN / GRILLE LINEAR SURFACE MOUNTED CONTINUOUS LED SYSTEM W/ FIXED MOUNTING CLIPS & FROSTED LENS / 3 WATTS PER FOOT, MLV/FWD ELECTRICAL OUTLET HEIGHTS (U.N.O) TYPICAL OUTLET - 15" A.F.F TYPICAL ACCESSIBLE WALL OUTLET - 18" A.F.F BATHROOM VANITY OUTLET - 42" A.F.F TYP. KITCHEN OUTLET - 42" A.F.F ADA KITCHEN OUTLET - 46" A.F.F ADA BATHROOM VANITY OUTLET - 44" A.F.F ELECTRICAL SWITCH HEIGHTS (U.N.O) SWITCH - 44" A.F.F THERMOSTAT REMOTE - 48" A.F.F MAX TO TOP OF SWITCH JUNCTION BOX DOOR BELL HARDWIRED TO DOORBELL LIGHT - MOUNT @ 46" A.F.F TO CENTER OF BUTTON (FOR COMMUNICATIONS FEATURES ROOMS ONLY) SD 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216UNIT INT. ELEVATIONS -EFFICIENCY STUDIOADA MOBILITY A-412B FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 1/2" = 1'-0" Reference: 1 / A-412 1EFFICIENCY ADA ELEVATION A Units 403 (Roll-In), 503 (Tub) 1/2" = 1'-0" Reference: 1 / A-412 2EFFICIENCY ADA ELEVATION B Units 403 (Roll-In), 503 (Tub) 1/2" = 1'-0" Reference: 1 / A-412 3EFFICIENCY ADA ELEVATION C Units 403 (Roll-In), 503 (Tub) 1/2" = 1'-0" Reference: 1 / A-412 4EFFICIENCY ADA ELEVATION D Units 403 (Roll-In), 503 (Tub) FFL FFL 0'1' 2'4' SCALE: 1/2" = 1'-0" KEYNOTES - UNIT PLANS 1 ALIGN 2 GENERAL CONTRACTOR TO COORDINATE W/ FURNITUREFABRICATOR WHERE NECESSARY TO PROVIDE PROPERBLOCKING IN WALL FOR ITEM KEYNOTED 3 NO FINISHES UNDER THE SHOWER PAN / TUB 4 NO FINISHES UNDER MILLWORK CABINETRY 5 TV AND MOUNT NOT TO PROJECT MORE THAN 4" FROMWALL 6 MOTORIZED BLINDS. PROVIDE JUNCTION BOX BEHINDVALENCE FOR POWER CONNECTION AND PERMANENTLYINSTALLED SWITCH ON WALL TO CONTROL BLINDS. 7 SWITCH CONTROLLING UNDER CABINET LIGHTING ATKITCHEN TO BE GANGED WITH LIGHTING AT ENTRY 8 SWITCH CONTROLLING GARBAGE DISPOSAL-REFER TOHADG FOR ACCESSIBLE ROOM REQ'S. 9 DEDICATED CIRCUIT FOR GARBAGE DISPOSAL 10 MASTER SWITCH 11 DEDICATED CIRCUIT FOR INDUCTION COOKTOP 12 DEDICATED CIRCUIT FOR DISHWASHER 13 DEDICATED CIRCUIT FOR REFRIGERATOR 14 ELECTRIC VANITY MIRROR - HARDWIRE FIXTURE TO WALL-CONTRACTOR TO VERIFY JBOX TYPE TO ENSURE PROPERINSTALLATION AND BACKING FOR ITEM KEYNOTED 15 DOORBELL AND DOORBELL ON/OFF SWITCH(COMMUNICATION FEATURES ROOMS ONLY)SIGNAGE ASREQ'D. 16 PLACE TV OUTLETS AND CONNECTIONS ON WALL OUTSIDEAREA OF BRACKET AND CONCEALED FROM VIEW BY TV 17 DEDICATED CIRCUIT FOR WASHER/DRYER. DIRECT VENTTO EXTERIOR FURNISHING SCHEDULE GUESTROOM FURNISHINGS GR-101 CHAIR - LOUNGE CHAIR IN STUIDOS GR-104 CHAIR - ADA DESK CHAIR GR-108 SOFA - SECTIONAL SLEEPER GR-201 SCONCE - NIGHTSTAND GR-205 LAMP - FLOOR LAMP GR-307 NIGHTSTAND - SMALL GR-308 NIGHTSTAND - REGULAR GR-311 DESK - ACCESSIBLE EFFICIENCY GR-312 TABLE - NESTING GR-316 CONSOLE - LIVING ROOM (1-BEDROOM) GR-319 CLOSET - EFFICIENCY SUITE GR-320 CLOSET - ACCESSIBLE EFFICIENCY SUITE GR-325 VANITY - EFFICIENCY SUITE GR-326 VANITY - STUDIO AND 1-BEDROOM SUITES GR-327 VANITY - ACCESSIBLE SUITES GR-328 BATH CADDY - ACCESSIBLE SUITES GR-400 STATIC DRAPARY PANELS GR-403 ROLLER SHADE - GUESTROOMS (MANUAL,SHEER/BLACK-OUT, 8' W) GR-405 ROLLER SHADE - GUESTROOMS (MANUAL,SHEER/BLACK-OUT, 8' W) GR-410 VALENCE FOR 5' WINDOW GR-501 ART GR-505 WALL HOOK GR-506 MIRROR - GUESTROOM FULL LENGTH GR-507 MIRROR - ADA VANITY GR-508 MIRROR - GUESTROOM VANITY GR-900 GUESTROOM REFRIGERATOR GR-901 GUESTROOM DISHWASHER GR-902 GUESTROOM COOKTOP - 2 BURNER GR-906GR-911 TELEVISION & TELEVISION MOUNT GR-907 CLOCK/RADIO GR-908 TELEPHONE - GUESTROOM GR-912 RECIRCULATING HOOD GR-913 COUNTERTOP MICROWAVE GR-ES BED - EFFICIENCY (GR-300, 303, 600) GR-KM BED - KING MOBILITY (GR-301, 304, 600, 602) PLUMBING/MECHANICAL FIXTURES PF-01 TOILET - GUESTROOM PF-03 SHOWER BASE - 60" X 36" WITH LINEARDRAIN PF-04 SHOWER BASE - 60" X 36" ADA ROLL-INSHOWER WITH EDGE TRENCH DRAIN PF-07 LAVATORY - UNDERMOUNT, 20" X 14" PF-10 SHOWER HEAD - HIGH PF-11 SHOWER HEAD - 2 IN 1 PF-12 SHOWER HEAD - HAND HELD ON SLIDE BAR PF-13 SHOWER/TUB VALVE & CONTROL PF-15 FAUCET - LAVATORY PF-42 SINK - ADA KITCHENETTE TOILET ACCESSORIES HD-01 DUAL TOILET PAPER HOLDER HD-04 WALL-MOUNTED ROBE HOOK HD-04.1 TOWEL BAR HD-05.1 STRAIGHT CURTAIN ROD AND SHOWERCURTAIN HD-05.2 SLIDING SHOWER DOOR HD-08 18" GRAB BAR HD-09 24" GRAB BAR HD-11 36" GRAB BAR HD-11.1 42" GRAB BAR HD-12 DOOR-MOUNTED ROBE HOOK HD-14 ROLL-IN SHOWER SEAT HD-16 BULK AMENITY DISPENSER ATSHOWERS/TUBS HD-18 FOOT LEDGE FOR SHOWER HD-18.1 SOAP SHELF HD-21 BULK AMENITY DISPENSER AT LAVATORIES EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV Revision Schedule Number Description Date MMAATVTV SD TV 402 SF EFFICIENCYENLARGED 303 A-413B2 1 4 3 A-413B 5 6 A-4231 XE1/2 8' - 3 1/2"6' - 6 3/4" 2' - 4 1/2"5' - 11" D-G03 4' - 2 1/2"6' - 9 1/2"7' - 9 3/4"12' - 10 1/4"11' - 6 1/4" 2' - 2 3/4" P3.1 GR-906GR-911 GR-100 GR-313 GR-200 GR-308 GR-201 GR-201 GR-308 GR-ES GR-310 GR-102 GR-325 GR-506 GR-908GR-907 GR-508 GR-501 D-G02A AP-01 GR-902 GR-900 GR-901 GR-400GR-400 D-G06 GR-319CL-B27' - 6" CL-B27' - 6" CL-B8' - 0" GR-400 GR-410 GR-400 VANITY2' - 4"2' - 4"3' - 4"5' - 3"1' - 0"7' - 2" 1 1 PLAN ELEV DUPLEX OUTLET QUADPLEX OUTLET GFCI OUTLET CAT6, RJ45 INTERNET OUTLET TELEPHONE OUTLET WALL MOUNTED WIRELESS THERMOSTAT POWER OUTLET WITH USB PORTS CATV OUTLET ELECTRICAL SWITCH FLOOR OUTLET POWER AND SIGNAL LEGEND: POWER SUPPLY CEILING FIXTURE LEGEND: 6" RECESSED CAN DOWNLIGHT DECORATIVE FLUSH MOUNT LIGHT PENDENT TYPE SPRINKLERS SMOKE DETECTOR EXHAUST FAN / GRILLE LINEAR SURFACE MOUNTED CONTINUOUS LED SYSTEM W/ FIXED MOUNTING CLIPS & FROSTED LENS / 3 WATTS PER FOOT, MLV/FWD ELECTRICAL OUTLET HEIGHTS (U.N.O) TYPICAL OUTLET - 15" A.F.F TYPICAL ACCESSIBLE WALL OUTLET - 18" A.F.F BATHROOM VANITY OUTLET - 42" A.F.F TYP. KITCHEN OUTLET - 42" A.F.F ADA KITCHEN OUTLET - 46" A.F.F ADA BATHROOM VANITY OUTLET - 44" A.F.F ELECTRICAL SWITCH HEIGHTS (U.N.O) SWITCH - 44" A.F.F THERMOSTAT REMOTE - 48" A.F.F MAX TO TOP OF SWITCH JUNCTION BOX DOOR BELL HARDWIRED TO DOORBELL LIGHT - MOUNT @ 46" A.F.F TO CENTER OF BUTTON (FOR COMMUNICATIONS FEATURES ROOMS ONLY) SD 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216UNIT PLAN -EFFICIENCY STUDIOENLARGED A-413 FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 1/2" = 1'-0" Reference: 1 / A-103 1EFFICIENCY ENLARGED UNIT CONSTRUCTION PLAN Units 203, 303 1/2" = 1'-0"2EFFICIENCY ENLARGED UNIT CONSTRUCTION PLAN Units 203, 303 0'1' 2'4' SCALE: 1/2" = 1'-0" 2 5 2 2 22 KEYNOTES - UNIT PLANS 1 ALIGN 2 GENERAL CONTRACTOR TO COORDINATE W/ FURNITUREFABRICATOR WHERE NECESSARY TO PROVIDE PROPERBLOCKING IN WALL FOR ITEM KEYNOTED 3 NO FINISHES UNDER THE SHOWER PAN / TUB 4 NO FINISHES UNDER MILLWORK CABINETRY 5 TV AND MOUNT NOT TO PROJECT MORE THAN 4" FROMWALL 6 MOTORIZED BLINDS. PROVIDE JUNCTION BOX BEHINDVALENCE FOR POWER CONNECTION AND PERMANENTLYINSTALLED SWITCH ON WALL TO CONTROL BLINDS. 7 SWITCH CONTROLLING UNDER CABINET LIGHTING ATKITCHEN TO BE GANGED WITH LIGHTING AT ENTRY 8 SWITCH CONTROLLING GARBAGE DISPOSAL-REFER TOHADG FOR ACCESSIBLE ROOM REQ'S. 9 DEDICATED CIRCUIT FOR GARBAGE DISPOSAL 10 MASTER SWITCH 11 DEDICATED CIRCUIT FOR INDUCTION COOKTOP 12 DEDICATED CIRCUIT FOR DISHWASHER 13 DEDICATED CIRCUIT FOR REFRIGERATOR 14 ELECTRIC VANITY MIRROR - HARDWIRE FIXTURE TO WALL-CONTRACTOR TO VERIFY JBOX TYPE TO ENSURE PROPERINSTALLATION AND BACKING FOR ITEM KEYNOTED 15 DOORBELL AND DOORBELL ON/OFF SWITCH(COMMUNICATION FEATURES ROOMS ONLY)SIGNAGE ASREQ'D. 16 PLACE TV OUTLETS AND CONNECTIONS ON WALL OUTSIDEAREA OF BRACKET AND CONCEALED FROM VIEW BY TV 17 DEDICATED CIRCUIT FOR WASHER/DRYER. DIRECT VENTTO EXTERIOR FURNISHING SCHEDULE GUESTROOM FURNISHINGS GR-100 CHAIR - LOUNGE CHAIR WITH OTTOMAN GR-102 CHAIR - COUNTER HEIGHT DESK CHAIR GR-200 SCONCE - PIN-UP GR-201 SCONCE - NIGHTSTAND GR-308 NIGHTSTAND - REGULAR GR-310 DESK - EFFICIENCY GR-313 TABLE - ROUND SIDE TABLE GR-316 CONSOLE - LIVING ROOM (1-BEDROOM) GR-319 CLOSET - EFFICIENCY SUITE GR-325 VANITY - EFFICIENCY SUITE GR-327 VANITY - ACCESSIBLE SUITES GR-400 STATIC DRAPARY PANELS GR-403 ROLLER SHADE - GUESTROOMS (MANUAL,SHEER/BLACK-OUT, 8' W) GR-410 VALENCE FOR 5' WINDOW GR-501 ART GR-503 ART- ENTRY GR-505 WALL HOOK GR-506 MIRROR - GUESTROOM FULL LENGTH GR-507 MIRROR - ADA VANITY GR-508 MIRROR - GUESTROOM VANITY GR-802 KITCHENETTE - EFFICIENCY SUITE GR-900 GUESTROOM REFRIGERATOR GR-901 GUESTROOM DISHWASHER GR-902 GUESTROOM COOKTOP - 2 BURNER GR-904 GARBAGE DISPOSAL 1/3HP GR-905 MICROWAVE- WITH RECIRCULATING HOOD GR-906GR-911 TELEVISION & TELEVISION MOUNT GR-907 CLOCK/RADIO GR-908 TELEPHONE - GUESTROOM GR-ES BED - EFFICIENCY (GR-300, 303, 600) OWNER SPECIFIED - OWNER FURNISHED OP-706 FIRE EXTINGUISHER CABINET PLUMBING/MECHANICAL FIXTURES PF-01 TOILET - GUESTROOM PF-03 SHOWER BASE - 60" X 36" WITH LINEARDRAIN PF-04 SHOWER BASE - 60" X 36" ADA ROLL-INSHOWER WITH EDGE TRENCH DRAIN PF-07 LAVATORY - UNDERMOUNT, 20" X 14" PF-11 SHOWER HEAD - 2 IN 1 PF-13 SHOWER/TUB VALVE & CONTROL PF-15 FAUCET - LAVATORY PF-40 SINK - KITCHENETTE PF-41 FAUCET - KITCHENETTE TOILET ACCESSORIES HD-01 DUAL TOILET PAPER HOLDER HD-02 DUAL TOILET PAPER HOLDER- ADA HD-04 WALL-MOUNTED ROBE HOOK HD-05.2 SLIDING SHOWER DOOR HD-08 18" GRAB BAR HD-11.1 42" GRAB BAR HD-16 BULK AMENITY DISPENSER ATSHOWERS/TUBS HD-18 FOOT LEDGE FOR SHOWER HD-18.1 SOAP SHELF HD-21 BULK AMENITY DISPENSER AT LAVATORIES EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV Revision Schedule Number Description Date TTVTV TV A-413B2 1 4 3 A-413B 5 6 SF-01 WC-01 WC-01 WC-01 WC-01 WC-01 WC-01 FULL TILE FULL TILEFULL TILEFULL TILE CPT-01 RES-01 CT-01 CPT-10 1 A-510 Sim 7 A-510 Sim 9 A-510 Sim 2 A-510 Sim PLAN ELEV DUPLEX OUTLET QUADPLEX OUTLET GFCI OUTLET CAT6, RJ45 INTERNET OUTLET TELEPHONE OUTLET WALL MOUNTED WIRELESS THERMOSTAT POWER OUTLET WITH USB PORTS CATV OUTLET ELECTRICAL SWITCH FLOOR OUTLET POWER AND SIGNAL LEGEND: POWER SUPPLY CEILING FIXTURE LEGEND: 6" RECESSED CAN DOWNLIGHT DECORATIVE FLUSH MOUNT LIGHT PENDENT TYPE SPRINKLERS SMOKE DETECTOR EXHAUST FAN / GRILLE LINEAR SURFACE MOUNTED CONTINUOUS LED SYSTEM W/ FIXED MOUNTING CLIPS & FROSTED LENS / 3 WATTS PER FOOT, MLV/FWD ELECTRICAL OUTLET HEIGHTS (U.N.O) TYPICAL OUTLET - 15" A.F.F TYPICAL ACCESSIBLE WALL OUTLET - 18" A.F.F BATHROOM VANITY OUTLET - 42" A.F.F TYP. KITCHEN OUTLET - 42" A.F.F ADA KITCHEN OUTLET - 46" A.F.F ADA BATHROOM VANITY OUTLET - 44" A.F.F ELECTRICAL SWITCH HEIGHTS (U.N.O) SWITCH - 44" A.F.F THERMOSTAT REMOTE - 48" A.F.F MAX TO TOP OF SWITCH JUNCTION BOX DOOR BELL HARDWIRED TO DOORBELL LIGHT - MOUNT @ 46" A.F.F TO CENTER OF BUTTON (FOR COMMUNICATIONS FEATURES ROOMS ONLY) SD 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216UNIT PLAN -EFFICIENCY STUDIOENLARGED - ELEC,DATA & FLOOR FINISHPLANA-413A FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 1/2" = 1'-0"1EFFICIENCY ENLARGED UNIT ELECTRICAL AND DATA PLAN Units 203, 303 1/2" = 1'-0"2EFFICIENCY ENLARGED UNIT FLOOR AND WALL FINISH PLAN Units 203, 303 0'1' 2'4' SCALE: 1/2" = 1'-0" 15 12 8 9 11 13 14 7 10 16 3 KEYNOTES - UNIT PLANS 1 ALIGN 2 GENERAL CONTRACTOR TO COORDINATE W/ FURNITUREFABRICATOR WHERE NECESSARY TO PROVIDE PROPERBLOCKING IN WALL FOR ITEM KEYNOTED 3 NO FINISHES UNDER THE SHOWER PAN / TUB 4 NO FINISHES UNDER MILLWORK CABINETRY 5 TV AND MOUNT NOT TO PROJECT MORE THAN 4" FROMWALL 6 MOTORIZED BLINDS. PROVIDE JUNCTION BOX BEHINDVALENCE FOR POWER CONNECTION AND PERMANENTLYINSTALLED SWITCH ON WALL TO CONTROL BLINDS. 7 SWITCH CONTROLLING UNDER CABINET LIGHTING ATKITCHEN TO BE GANGED WITH LIGHTING AT ENTRY 8 SWITCH CONTROLLING GARBAGE DISPOSAL-REFER TOHADG FOR ACCESSIBLE ROOM REQ'S. 9 DEDICATED CIRCUIT FOR GARBAGE DISPOSAL 10 MASTER SWITCH 11 DEDICATED CIRCUIT FOR INDUCTION COOKTOP 12 DEDICATED CIRCUIT FOR DISHWASHER 13 DEDICATED CIRCUIT FOR REFRIGERATOR 14 ELECTRIC VANITY MIRROR - HARDWIRE FIXTURE TO WALL-CONTRACTOR TO VERIFY JBOX TYPE TO ENSURE PROPERINSTALLATION AND BACKING FOR ITEM KEYNOTED 15 DOORBELL AND DOORBELL ON/OFF SWITCH(COMMUNICATION FEATURES ROOMS ONLY)SIGNAGE ASREQ'D. 16 PLACE TV OUTLETS AND CONNECTIONS ON WALL OUTSIDEAREA OF BRACKET AND CONCEALED FROM VIEW BY TV 17 DEDICATED CIRCUIT FOR WASHER/DRYER. DIRECT VENTTO EXTERIOR FURNISHING SCHEDULE GUESTROOM FURNISHINGS GR-100 CHAIR - LOUNGE CHAIR WITH OTTOMAN GR-102 CHAIR - COUNTER HEIGHT DESK CHAIR GR-200 SCONCE - PIN-UP GR-201 SCONCE - NIGHTSTAND GR-308 NIGHTSTAND - REGULAR GR-310 DESK - EFFICIENCY GR-313 TABLE - ROUND SIDE TABLE GR-319 CLOSET - EFFICIENCY SUITE GR-325 VANITY - EFFICIENCY SUITE GR-400 STATIC DRAPARY PANELS GR-501 ART GR-503 ART- ENTRY GR-506 MIRROR - GUESTROOM FULL LENGTH GR-508 MIRROR - GUESTROOM VANITY GR-802 KITCHENETTE - EFFICIENCY SUITE GR-900 GUESTROOM REFRIGERATOR GR-901 GUESTROOM DISHWASHER GR-902 GUESTROOM COOKTOP - 2 BURNER GR-904 GARBAGE DISPOSAL 1/3HP GR-906GR-911 TELEVISION & TELEVISION MOUNT GR-907 CLOCK/RADIO GR-908 TELEPHONE - GUESTROOM GR-ES BED - EFFICIENCY (GR-300, 303, 600) PLUMBING/MECHANICAL FIXTURES PF-01 TOILET - GUESTROOM PF-03 SHOWER BASE - 60" X 36" WITH LINEARDRAIN PF-07 LAVATORY - UNDERMOUNT, 20" X 14" PF-11 SHOWER HEAD - 2 IN 1 PF-13 SHOWER/TUB VALVE & CONTROL PF-15 FAUCET - LAVATORY PF-40 SINK - KITCHENETTE PF-41 FAUCET - KITCHENETTE TOILET ACCESSORIES HD-01 DUAL TOILET PAPER HOLDER HD-05.2 SLIDING SHOWER DOOR HD-08 18" GRAB BAR HD-16 BULK AMENITY DISPENSER ATSHOWERS/TUBS HD-18 FOOT LEDGE FOR SHOWER HD-18.1 SOAP SHELF HD-21 BULK AMENITY DISPENSER AT LAVATORIES EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV Revision Schedule Number Description Date TV WC-01WD-01 WD-01 5' - 1"6' - 2"4' - 3 1/4" WC-01 RB-01 0' - 9 1/2" GR-902 GR-900 GR-901 AP-01 D-G02A GR-410 WC-01 WD-01WD-01 5' - 2"1' - 10 3/4"GR-403 3' - 10"W-H RB-01 RB-01 SS-01 WC-01 GR-410 GR-403 GR-400 WC-01 RB-01 WC-01 RB-01 GR-505 0' - 8" 2' - 10 3/4"5' - 0"0' - 6"WC-01WC-01 RB-01 WD-01 WD-01 SS-01 W-H 4' - 2"5' - 5 1/2" SF-01 RB-01 GR-410 16 A-510 Sim GR-403 GR-400 PLAN ELEV DUPLEX OUTLET QUADPLEX OUTLET GFCI OUTLET CAT6, RJ45 INTERNET OUTLET TELEPHONE OUTLET WALL MOUNTED WIRELESS THERMOSTAT POWER OUTLET WITH USB PORTS CATV OUTLET ELECTRICAL SWITCH FLOOR OUTLET POWER AND SIGNAL LEGEND: POWER SUPPLY CEILING FIXTURE LEGEND: 6" RECESSED CAN DOWNLIGHT DECORATIVE FLUSH MOUNT LIGHT PENDENT TYPE SPRINKLERS SMOKE DETECTOR EXHAUST FAN / GRILLE LINEAR SURFACE MOUNTED CONTINUOUS LED SYSTEM W/ FIXED MOUNTING CLIPS & FROSTED LENS / 3 WATTS PER FOOT, MLV/FWD ELECTRICAL OUTLET HEIGHTS (U.N.O) TYPICAL OUTLET - 15" A.F.F TYPICAL ACCESSIBLE WALL OUTLET - 18" A.F.F BATHROOM VANITY OUTLET - 42" A.F.F TYP. KITCHEN OUTLET - 42" A.F.F ADA KITCHEN OUTLET - 46" A.F.F ADA BATHROOM VANITY OUTLET - 44" A.F.F ELECTRICAL SWITCH HEIGHTS (U.N.O) SWITCH - 44" A.F.F THERMOSTAT REMOTE - 48" A.F.F MAX TO TOP OF SWITCH JUNCTION BOX DOOR BELL HARDWIRED TO DOORBELL LIGHT - MOUNT @ 46" A.F.F TO CENTER OF BUTTON (FOR COMMUNICATIONS FEATURES ROOMS ONLY) SD 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216UNIT INT. ELEVATIONS -EFFICIENCY STUDIOENLARGED A-413B FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 FFL FFL 1/2" = 1'-0" Reference: 1 / A-413 1EFFICIENCY ENLARGED ELEVATION A Units 203, 303 1/2" = 1'-0" Reference: 1 / A-413 2EFFICIENCY ENLARGED ELEVATION B Units 203, 303 1/2" = 1'-0" Reference: 1 / A-413 3EFFICIENCY ENLARGED ELEVATION C Units 203, 303 1/2" = 1'-0" Reference: 1 / A-413 4EFFICIENCY ENLARGED ELEVATION D Units 203, 303 FFL 1/2" = 1'-0" Reference: 1 / A-413 5EFFICIENCY ENLARGED ELEVATION E Units 203, 303 1/2" = 1'-0" Reference: 1 / A-413 6EFFICIENCY ENLARGED ELEVATION F Units 203, 303 0'1' 2'4' SCALE: 1/2" = 1'-0" KEYNOTES - UNIT PLANS 1 ALIGN 2 GENERAL CONTRACTOR TO COORDINATE W/ FURNITUREFABRICATOR WHERE NECESSARY TO PROVIDE PROPERBLOCKING IN WALL FOR ITEM KEYNOTED 3 NO FINISHES UNDER THE SHOWER PAN / TUB 4 NO FINISHES UNDER MILLWORK CABINETRY 5 TV AND MOUNT NOT TO PROJECT MORE THAN 4" FROMWALL 6 MOTORIZED BLINDS. PROVIDE JUNCTION BOX BEHINDVALENCE FOR POWER CONNECTION AND PERMANENTLYINSTALLED SWITCH ON WALL TO CONTROL BLINDS. 7 SWITCH CONTROLLING UNDER CABINET LIGHTING ATKITCHEN TO BE GANGED WITH LIGHTING AT ENTRY 8 SWITCH CONTROLLING GARBAGE DISPOSAL-REFER TOHADG FOR ACCESSIBLE ROOM REQ'S. 9 DEDICATED CIRCUIT FOR GARBAGE DISPOSAL 10 MASTER SWITCH 11 DEDICATED CIRCUIT FOR INDUCTION COOKTOP 12 DEDICATED CIRCUIT FOR DISHWASHER 13 DEDICATED CIRCUIT FOR REFRIGERATOR 14 ELECTRIC VANITY MIRROR - HARDWIRE FIXTURE TO WALL-CONTRACTOR TO VERIFY JBOX TYPE TO ENSURE PROPERINSTALLATION AND BACKING FOR ITEM KEYNOTED 15 DOORBELL AND DOORBELL ON/OFF SWITCH(COMMUNICATION FEATURES ROOMS ONLY)SIGNAGE ASREQ'D. 16 PLACE TV OUTLETS AND CONNECTIONS ON WALL OUTSIDEAREA OF BRACKET AND CONCEALED FROM VIEW BY TV 17 DEDICATED CIRCUIT FOR WASHER/DRYER. DIRECT VENTTO EXTERIOR FURNISHING SCHEDULE GUESTROOM FURNISHINGS GR-100 CHAIR - LOUNGE CHAIR WITH OTTOMAN GR-101 CHAIR - LOUNGE CHAIR IN STUIDOS GR-102 CHAIR - COUNTER HEIGHT DESK CHAIR GR-105 SOFA - SLEEP BETWEEN ARMS GR-200 SCONCE - PIN-UP GR-201 SCONCE - NIGHTSTAND GR-205 LAMP - FLOOR LAMP GR-307 NIGHTSTAND - SMALL GR-308 NIGHTSTAND - REGULAR GR-310 DESK - EFFICIENCY GR-312 TABLE - NESTING GR-313 TABLE - ROUND SIDE TABLE GR-316 CONSOLE - LIVING ROOM (1-BEDROOM) GR-319 CLOSET - EFFICIENCY SUITE GR-325 VANITY - EFFICIENCY SUITE GR-327 VANITY - ACCESSIBLE SUITES GR-328 BATH CADDY - ACCESSIBLE SUITES GR-400 STATIC DRAPARY PANELS GR-403 ROLLER SHADE - GUESTROOMS (MANUAL,SHEER/BLACK-OUT, 8' W) GR-405 ROLLER SHADE - GUESTROOMS (MANUAL,SHEER/BLACK-OUT, 8' W) GR-410 VALENCE FOR 5' WINDOW GR-501 ART GR-503 ART- ENTRY GR-505 WALL HOOK GR-506 MIRROR - GUESTROOM FULL LENGTH GR-507 MIRROR - ADA VANITY GR-508 MIRROR - GUESTROOM VANITY GR-802 KITCHENETTE - EFFICIENCY SUITE GR-900 GUESTROOM REFRIGERATOR GR-901 GUESTROOM DISHWASHER GR-902 GUESTROOM COOKTOP - 2 BURNER GR-904 GARBAGE DISPOSAL 1/3HP GR-905 MICROWAVE- WITH RECIRCULATING HOOD GR-906GR-911 TELEVISION & TELEVISION MOUNT GR-907 CLOCK/RADIO GR-908 TELEPHONE - GUESTROOM GR-ES BED - EFFICIENCY (GR-300, 303, 600) PLUMBING/MECHANICAL FIXTURES PF-01 TOILET - GUESTROOM PF-03 SHOWER BASE - 60" X 36" WITH LINEARDRAIN PF-06 BATHTUB - 5' X 32" WITH SIDE LEDGE PF-07 LAVATORY - UNDERMOUNT, 20" X 14" PF-10 SHOWER HEAD - HIGH PF-11 SHOWER HEAD - 2 IN 1 PF-12 SHOWER HEAD - HAND HELD ON SLIDE BAR PF-13 SHOWER/TUB VALVE & CONTROL PF-14 BATHTUB FILL FAUCET PF-15 FAUCET - LAVATORY PF-40 SINK - KITCHENETTE PF-41 FAUCET - KITCHENETTE TOILET ACCESSORIES HD-01 DUAL TOILET PAPER HOLDER HD-02 DUAL TOILET PAPER HOLDER- ADA HD-04 WALL-MOUNTED ROBE HOOK HD-04.1 TOWEL BAR HD-05 CURVED CURTAIN ROD AND SHOWERCURTAIN HD-05.2 SLIDING SHOWER DOOR HD-08 18" GRAB BAR HD-09 24" GRAB BAR HD-10 42" GRAB BAR AT ADA BATHTUB HD-11 36" GRAB BAR HD-11.1 42" GRAB BAR HD-14.1 ROLL-IN SHOWER SEAT HD-16 BULK AMENITY DISPENSER ATSHOWERS/TUBS HD-18 FOOT LEDGE FOR SHOWER HD-18.1 SOAP SHELF HD-20 12" GRAB BAR HD-21 BULK AMENITY DISPENSER AT LAVATORIES EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV Revision Schedule Number Description Date MMAATVSD TV OF-705 OF-702OF-702 D-G04 A-414B4 1 2 3 D-G02 P3.1 GR-400 GR-400 8' - 0" 4' - 7" 12' - 4"6' - 1"11' - 10"4' - 10 3/4"6' - 5"22' - 11"D-G01 D-G03 GR-504GR-908 GR-907 GR-308 GR-KS GR-201 GR-906GR-911 GR-801 GR-103 GR-103 GR-318 GR-321 GR-105 GR-312 GR-308 GR-201 GR-901 18' - 5" A-4251 GR-508 GR-902 GR-506 OF-702AOF-705OF-702A 5' - 1"11' - 6 1/2" D-G04 3' - 1 3/4"1' - 5"1' - 5"4' - 6"4' - 6" OF BED OF TABLE 2' - 1 1/4" A-4253 CL-B8' - 0" CL-B27' - 6" CL-B27' - 6" PLAN ELEV DUPLEX OUTLET QUADPLEX OUTLET GFCI OUTLET CAT6, RJ45 INTERNET OUTLET TELEPHONE OUTLET WALL MOUNTED WIRELESS THERMOSTAT POWER OUTLET WITH USB PORTS CATV OUTLET ELECTRICAL SWITCH FLOOR OUTLET POWER AND SIGNAL LEGEND: POWER SUPPLY CEILING FIXTURE LEGEND: 6" RECESSED CAN DOWNLIGHT DECORATIVE FLUSH MOUNT LIGHT PENDENT TYPE SPRINKLERS SMOKE DETECTOR EXHAUST FAN / GRILLE LINEAR SURFACE MOUNTED CONTINUOUS LED SYSTEM W/ FIXED MOUNTING CLIPS & FROSTED LENS / 3 WATTS PER FOOT, MLV/FWD ELECTRICAL OUTLET HEIGHTS (U.N.O) TYPICAL OUTLET - 15" A.F.F TYPICAL ACCESSIBLE WALL OUTLET - 18" A.F.F BATHROOM VANITY OUTLET - 42" A.F.F TYP. KITCHEN OUTLET - 42" A.F.F ADA KITCHEN OUTLET - 46" A.F.F ADA BATHROOM VANITY OUTLET - 44" A.F.F ELECTRICAL SWITCH HEIGHTS (U.N.O) SWITCH - 44" A.F.F THERMOSTAT REMOTE - 48" A.F.F MAX TO TOP OF SWITCH JUNCTION BOX DOOR BELL HARDWIRED TO DOORBELL LIGHT - MOUNT @ 46" A.F.F TO CENTER OF BUTTON (FOR COMMUNICATIONS FEATURES ROOMS ONLY) SD 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216UNIT PLAN - KINGSTUDIO A-414 FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 1/2" = 1'-0" Reference: 1 / A-102 1KING STUDIO CONSTRUCTION PLAN Units x04, x14, x16, x18-x21, x23, x25-x26, x30, x37 1/2" = 1'-0" Reference: 1 / A-102 2KING STUDIO BALCONY PLAN Units x18, x21, x23, x25, 237, 337, 437, 537 1/2" = 1'-0"3KING STUDIO REFLECTED CEILING PLAN Units x04, x14, x16, x18-x21, x23, x25-x26, x30, x37 1/2" = 1'-0" Reference: 1 / A-101 4KING STUDIO LANAI PLAN Unit 137 0'1' 2'4' SCALE: 1/2" = 1'-0" 2 2 2 2 5 2 1 1 1 KEYNOTES - UNIT PLANS 1 ALIGN 2 GENERAL CONTRACTOR TO COORDINATE W/ FURNITUREFABRICATOR WHERE NECESSARY TO PROVIDE PROPERBLOCKING IN WALL FOR ITEM KEYNOTED 3 NO FINISHES UNDER THE SHOWER PAN / TUB 4 NO FINISHES UNDER MILLWORK CABINETRY 5 TV AND MOUNT NOT TO PROJECT MORE THAN 4" FROMWALL 6 MOTORIZED BLINDS. PROVIDE JUNCTION BOX BEHINDVALENCE FOR POWER CONNECTION AND PERMANENTLYINSTALLED SWITCH ON WALL TO CONTROL BLINDS. 7 SWITCH CONTROLLING UNDER CABINET LIGHTING ATKITCHEN TO BE GANGED WITH LIGHTING AT ENTRY 8 SWITCH CONTROLLING GARBAGE DISPOSAL-REFER TOHADG FOR ACCESSIBLE ROOM REQ'S. 9 DEDICATED CIRCUIT FOR GARBAGE DISPOSAL 10 MASTER SWITCH 11 DEDICATED CIRCUIT FOR INDUCTION COOKTOP 12 DEDICATED CIRCUIT FOR DISHWASHER 13 DEDICATED CIRCUIT FOR REFRIGERATOR 14 ELECTRIC VANITY MIRROR - HARDWIRE FIXTURE TO WALL-CONTRACTOR TO VERIFY JBOX TYPE TO ENSURE PROPERINSTALLATION AND BACKING FOR ITEM KEYNOTED 15 DOORBELL AND DOORBELL ON/OFF SWITCH(COMMUNICATION FEATURES ROOMS ONLY)SIGNAGE ASREQ'D. 16 PLACE TV OUTLETS AND CONNECTIONS ON WALL OUTSIDEAREA OF BRACKET AND CONCEALED FROM VIEW BY TV 17 DEDICATED CIRCUIT FOR WASHER/DRYER. DIRECT VENTTO EXTERIOR FURNISHING SCHEDULE GUESTROOM FURNISHINGS GR-103 CHAIR - KITCHEN STOOL GR-105 SOFA - SLEEP BETWEEN ARMS GR-201 SCONCE - NIGHTSTAND GR-203 PENDANT LIGHT - PRODUCTIVITY TABLE GR-205 LAMP - FLOOR LAMP GR-308 NIGHTSTAND - REGULAR GR-312 TABLE - NESTING GR-314 TABLE - PRODUCTIVITY TABLE (STUDIO) GR-318 DRESSER - HIGHBOY GR-321 CLOSET - KING STUDIO SUITE GR-326 VANITY - STUDIO AND 1-BEDROOM SUITES GR-400 STATIC DRAPARY PANELS GR-403 ROLLER SHADE - GUESTROOMS (MANUAL,SHEER/BLACK-OUT, 8' W) GR-412 VALENCE FOR 8' WINDOW GR-503 ART- ENTRY GR-504 ART- SLEEPING/LIVING GR-505 WALL HOOK GR-506 MIRROR - GUESTROOM FULL LENGTH GR-508 MIRROR - GUESTROOM VANITY GR-800 KITCHENETTE - 1-BEDROOM GR-900 GUESTROOM REFRIGERATOR GR-901 GUESTROOM DISHWASHER GR-902 GUESTROOM COOKTOP - 2 BURNER GR-904 GARBAGE DISPOSAL 1/3HP GR-905 MICROWAVE- WITH RECIRCULATING HOOD GR-906GR-911 TELEVISION & TELEVISION MOUNT GR-907 CLOCK/RADIO GR-908 TELEPHONE - GUESTROOM GR-KS BED - KING (GR-301, 303, 600) HILTON SPECIFIED - OWNER FURNISHED OF-702 CHAIR - OUDOOR DINING CHAIR OF-702A CHAIR - BALCONY CHAIR OF-705 TABLE - 17" D OUTDOOR SIDE TABLE PLUMBING/MECHANICAL FIXTURES PF-01 TOILET - GUESTROOM PF-03 SHOWER BASE - 60" X 36" WITH LINEARDRAIN PF-07 LAVATORY - UNDERMOUNT, 20" X 14" PF-11 SHOWER HEAD - 2 IN 1 PF-13 SHOWER/TUB VALVE & CONTROL PF-15 FAUCET - LAVATORY PF-40 SINK - KITCHENETTE PF-41 FAUCET - KITCHENETTE TOILET ACCESSORIES HD-01 DUAL TOILET PAPER HOLDER HD-04 WALL-MOUNTED ROBE HOOK HD-04.1 TOWEL BAR HD-05.2 SLIDING SHOWER DOOR HD-08 18" GRAB BAR HD-16 BULK AMENITY DISPENSER ATSHOWERS/TUBS HD-18 FOOT LEDGE FOR SHOWER HD-18.1 SOAP SHELF HD-21 BULK AMENITY DISPENSER AT LAVATORIES EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV Revision Schedule Number Description Date TVTV A-414B4 1 2 3 SF-01 WC-01 WC-01 WC-01 WC-01 WC-01 CPT-10 RES-01 CPT-01 CT-01 FULL TILEFULL TILE 1 A-510 Sim 8' - 5 3/4" 7 A-510 Sim 1 A-510 Sim 9 A-510 Sim PLAN ELEV DUPLEX OUTLET QUADPLEX OUTLET GFCI OUTLET CAT6, RJ45 INTERNET OUTLET TELEPHONE OUTLET WALL MOUNTED WIRELESS THERMOSTAT POWER OUTLET WITH USB PORTS CATV OUTLET ELECTRICAL SWITCH FLOOR OUTLET POWER AND SIGNAL LEGEND: POWER SUPPLY CEILING FIXTURE LEGEND: 6" RECESSED CAN DOWNLIGHT DECORATIVE FLUSH MOUNT LIGHT PENDENT TYPE SPRINKLERS SMOKE DETECTOR EXHAUST FAN / GRILLE LINEAR SURFACE MOUNTED CONTINUOUS LED SYSTEM W/ FIXED MOUNTING CLIPS & FROSTED LENS / 3 WATTS PER FOOT, MLV/FWD ELECTRICAL OUTLET HEIGHTS (U.N.O) TYPICAL OUTLET - 15" A.F.F TYPICAL ACCESSIBLE WALL OUTLET - 18" A.F.F BATHROOM VANITY OUTLET - 42" A.F.F TYP. KITCHEN OUTLET - 42" A.F.F ADA KITCHEN OUTLET - 46" A.F.F ADA BATHROOM VANITY OUTLET - 44" A.F.F ELECTRICAL SWITCH HEIGHTS (U.N.O) SWITCH - 44" A.F.F THERMOSTAT REMOTE - 48" A.F.F MAX TO TOP OF SWITCH JUNCTION BOX DOOR BELL HARDWIRED TO DOORBELL LIGHT - MOUNT @ 46" A.F.F TO CENTER OF BUTTON (FOR COMMUNICATIONS FEATURES ROOMS ONLY) SD 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216UNIT PLAN - KINGSTUDIO - ELEC, DATA &FLOOR FINISH PLAN A-414A FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 1/2" = 1'-0"1KING STUDIO ELECTRICAL & DATA PLAN Units x04, x14, x16, x18-x21, x23, x25-x26, x30, x37 1/2" = 1'-0"2KING STUDIO FLOOR & WALL FINISH PLAN Units x04, x14, x16, x18-x21, x23, x25-x26, x30, x37 0'1' 2'4' SCALE: 1/2" = 1'-0" 3 15 12 8 9 11 13 7 10 16 KEYNOTES - UNIT PLANS 1 ALIGN 2 GENERAL CONTRACTOR TO COORDINATE W/ FURNITUREFABRICATOR WHERE NECESSARY TO PROVIDE PROPERBLOCKING IN WALL FOR ITEM KEYNOTED 3 NO FINISHES UNDER THE SHOWER PAN / TUB 4 NO FINISHES UNDER MILLWORK CABINETRY 5 TV AND MOUNT NOT TO PROJECT MORE THAN 4" FROMWALL 6 MOTORIZED BLINDS. PROVIDE JUNCTION BOX BEHINDVALENCE FOR POWER CONNECTION AND PERMANENTLYINSTALLED SWITCH ON WALL TO CONTROL BLINDS. 7 SWITCH CONTROLLING UNDER CABINET LIGHTING ATKITCHEN TO BE GANGED WITH LIGHTING AT ENTRY 8 SWITCH CONTROLLING GARBAGE DISPOSAL-REFER TOHADG FOR ACCESSIBLE ROOM REQ'S. 9 DEDICATED CIRCUIT FOR GARBAGE DISPOSAL 10 MASTER SWITCH 11 DEDICATED CIRCUIT FOR INDUCTION COOKTOP 12 DEDICATED CIRCUIT FOR DISHWASHER 13 DEDICATED CIRCUIT FOR REFRIGERATOR 14 ELECTRIC VANITY MIRROR - HARDWIRE FIXTURE TO WALL-CONTRACTOR TO VERIFY JBOX TYPE TO ENSURE PROPERINSTALLATION AND BACKING FOR ITEM KEYNOTED 15 DOORBELL AND DOORBELL ON/OFF SWITCH(COMMUNICATION FEATURES ROOMS ONLY)SIGNAGE ASREQ'D. 16 PLACE TV OUTLETS AND CONNECTIONS ON WALL OUTSIDEAREA OF BRACKET AND CONCEALED FROM VIEW BY TV 17 DEDICATED CIRCUIT FOR WASHER/DRYER. DIRECT VENTTO EXTERIOR FURNISHING SCHEDULE GUESTROOM FURNISHINGS GR-103 CHAIR - KITCHEN STOOL GR-105 SOFA - SLEEP BETWEEN ARMS GR-201 SCONCE - NIGHTSTAND GR-205 LAMP - FLOOR LAMP GR-308 NIGHTSTAND - REGULAR GR-312 TABLE - NESTING GR-314 TABLE - PRODUCTIVITY TABLE (STUDIO) GR-318 DRESSER - HIGHBOY GR-321 CLOSET - KING STUDIO SUITE GR-326 VANITY - STUDIO AND 1-BEDROOM SUITES GR-400 STATIC DRAPARY PANELS GR-504 ART- SLEEPING/LIVING GR-506 MIRROR - GUESTROOM FULL LENGTH GR-508 MIRROR - GUESTROOM VANITY GR-800 KITCHENETTE - 1-BEDROOM GR-900 GUESTROOM REFRIGERATOR GR-901 GUESTROOM DISHWASHER GR-902 GUESTROOM COOKTOP - 2 BURNER GR-904 GARBAGE DISPOSAL 1/3HP GR-906GR-911 TELEVISION & TELEVISION MOUNT GR-907 CLOCK/RADIO GR-908 TELEPHONE - GUESTROOM GR-KS BED - KING (GR-301, 303, 600) PLUMBING/MECHANICAL FIXTURES PF-01 TOILET - GUESTROOM PF-03 SHOWER BASE - 60" X 36" WITH LINEARDRAIN PF-07 LAVATORY - UNDERMOUNT, 20" X 14" PF-11 SHOWER HEAD - 2 IN 1 PF-13 SHOWER/TUB VALVE & CONTROL PF-15 FAUCET - LAVATORY PF-40 SINK - KITCHENETTE PF-41 FAUCET - KITCHENETTE TOILET ACCESSORIES HD-01 DUAL TOILET PAPER HOLDER HD-04.1 TOWEL BAR HD-05.2 SLIDING SHOWER DOOR HD-08 18" GRAB BAR HD-16 BULK AMENITY DISPENSER ATSHOWERS/TUBS HD-18 FOOT LEDGE FOR SHOWER HD-18.1 SOAP SHELF HD-21 BULK AMENITY DISPENSER AT LAVATORIES EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV Revision Schedule Number Description Date TV WC-01 0' - 8" 2' - 3 1/2"5' - 0"RB-01 WD-01 WD-01 GR-505 D-G01 PT-11PL-01 GR-504 GR-321 5' - 2"3' - 2 1/4"2' - 2 1/4" D-G03 GR-503 GR-508 GR-318 GR-KS PT-03PL-02WC-01WC-01 RB-01 SF-01 W-G RB-01 SF-01 GR-412 GR-400GR-403 2' - 7 1/4" WC-01 PT-03 PL-02 5' - 1"4' - 2"RB-01 WD-01 WD-01 WC-01 D-G02 PLAN ELEV DUPLEX OUTLET QUADPLEX OUTLET GFCI OUTLET CAT6, RJ45 INTERNET OUTLET TELEPHONE OUTLET WALL MOUNTED WIRELESS THERMOSTAT POWER OUTLET WITH USB PORTS CATV OUTLET ELECTRICAL SWITCH FLOOR OUTLET POWER AND SIGNAL LEGEND: POWER SUPPLY CEILING FIXTURE LEGEND: 6" RECESSED CAN DOWNLIGHT DECORATIVE FLUSH MOUNT LIGHT PENDENT TYPE SPRINKLERS SMOKE DETECTOR EXHAUST FAN / GRILLE LINEAR SURFACE MOUNTED CONTINUOUS LED SYSTEM W/ FIXED MOUNTING CLIPS & FROSTED LENS / 3 WATTS PER FOOT, MLV/FWD ELECTRICAL OUTLET HEIGHTS (U.N.O) TYPICAL OUTLET - 15" A.F.F TYPICAL ACCESSIBLE WALL OUTLET - 18" A.F.F BATHROOM VANITY OUTLET - 42" A.F.F TYP. KITCHEN OUTLET - 42" A.F.F ADA KITCHEN OUTLET - 46" A.F.F ADA BATHROOM VANITY OUTLET - 44" A.F.F ELECTRICAL SWITCH HEIGHTS (U.N.O) SWITCH - 44" A.F.F THERMOSTAT REMOTE - 48" A.F.F MAX TO TOP OF SWITCH JUNCTION BOX DOOR BELL HARDWIRED TO DOORBELL LIGHT - MOUNT @ 46" A.F.F TO CENTER OF BUTTON (FOR COMMUNICATIONS FEATURES ROOMS ONLY) SD 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216UNIT INT. ELEVATIONS -KING STUDIO A-414B FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 1/2" = 1'-0" Reference: 1 / A-414 1KING STUDIO ELEVATION A Units x05, 307, 407, 507, x08, x27-x29, x31, x33-x34 1/2" = 1'-0" Reference: 1 / A-414 2KING STUDIO ELEVATION B Units x05, 307, 407, 507, x08, x27-x29, x31, x33-x34 1/2" = 1'-0" Reference: 1 / A-414 3KING STUDIO ELEVATION C Units x05, 307, 407, 507, x08, x27-x29, x31, x33-x34 1/2" = 1'-0" Reference: 1 / A-414 4KING STUDIO ELEVATION D Units x05, 307, 407, 507, x08, x27-x29, x31, x33-x34 FFL FFL 0'1' 2'4' SCALE: 1/2" = 1'-0" KEYNOTES - UNIT PLANS 1 ALIGN 2 GENERAL CONTRACTOR TO COORDINATE W/ FURNITUREFABRICATOR WHERE NECESSARY TO PROVIDE PROPERBLOCKING IN WALL FOR ITEM KEYNOTED 3 NO FINISHES UNDER THE SHOWER PAN / TUB 4 NO FINISHES UNDER MILLWORK CABINETRY 5 TV AND MOUNT NOT TO PROJECT MORE THAN 4" FROMWALL 6 MOTORIZED BLINDS. PROVIDE JUNCTION BOX BEHINDVALENCE FOR POWER CONNECTION AND PERMANENTLYINSTALLED SWITCH ON WALL TO CONTROL BLINDS. 7 SWITCH CONTROLLING UNDER CABINET LIGHTING ATKITCHEN TO BE GANGED WITH LIGHTING AT ENTRY 8 SWITCH CONTROLLING GARBAGE DISPOSAL-REFER TOHADG FOR ACCESSIBLE ROOM REQ'S. 9 DEDICATED CIRCUIT FOR GARBAGE DISPOSAL 10 MASTER SWITCH 11 DEDICATED CIRCUIT FOR INDUCTION COOKTOP 12 DEDICATED CIRCUIT FOR DISHWASHER 13 DEDICATED CIRCUIT FOR REFRIGERATOR 14 ELECTRIC VANITY MIRROR - HARDWIRE FIXTURE TO WALL-CONTRACTOR TO VERIFY JBOX TYPE TO ENSURE PROPERINSTALLATION AND BACKING FOR ITEM KEYNOTED 15 DOORBELL AND DOORBELL ON/OFF SWITCH(COMMUNICATION FEATURES ROOMS ONLY)SIGNAGE ASREQ'D. 16 PLACE TV OUTLETS AND CONNECTIONS ON WALL OUTSIDEAREA OF BRACKET AND CONCEALED FROM VIEW BY TV 17 DEDICATED CIRCUIT FOR WASHER/DRYER. DIRECT VENTTO EXTERIOR FURNISHING SCHEDULE GUESTROOM FURNISHINGS GR-103 CHAIR - KITCHEN STOOL GR-105 SOFA - SLEEP BETWEEN ARMS GR-201 SCONCE - NIGHTSTAND GR-203 PENDANT LIGHT - PRODUCTIVITY TABLE GR-205 LAMP - FLOOR LAMP GR-308 NIGHTSTAND - REGULAR GR-312 TABLE - NESTING GR-314 TABLE - PRODUCTIVITY TABLE (STUDIO) GR-318 DRESSER - HIGHBOY GR-321 CLOSET - KING STUDIO SUITE GR-326 VANITY - STUDIO AND 1-BEDROOM SUITES GR-400 STATIC DRAPARY PANELS GR-403 ROLLER SHADE - GUESTROOMS (MANUAL,SHEER/BLACK-OUT, 8' W) GR-412 VALENCE FOR 8' WINDOW GR-503 ART- ENTRY GR-504 ART- SLEEPING/LIVING GR-505 WALL HOOK GR-506 MIRROR - GUESTROOM FULL LENGTH GR-508 MIRROR - GUESTROOM VANITY GR-800 KITCHENETTE - 1-BEDROOM GR-900 GUESTROOM REFRIGERATOR GR-901 GUESTROOM DISHWASHER GR-902 GUESTROOM COOKTOP - 2 BURNER GR-904 GARBAGE DISPOSAL 1/3HP GR-905 MICROWAVE- WITH RECIRCULATING HOOD GR-906GR-911 TELEVISION & TELEVISION MOUNT GR-907 CLOCK/RADIO GR-908 TELEPHONE - GUESTROOM GR-KS BED - KING (GR-301, 303, 600) PLUMBING/MECHANICAL FIXTURES PF-01 TOILET - GUESTROOM PF-03 SHOWER BASE - 60" X 36" WITH LINEARDRAIN PF-07 LAVATORY - UNDERMOUNT, 20" X 14" PF-11 SHOWER HEAD - 2 IN 1 PF-13 SHOWER/TUB VALVE & CONTROL PF-15 FAUCET - LAVATORY PF-40 SINK - KITCHENETTE PF-41 FAUCET - KITCHENETTE TOILET ACCESSORIES HD-01 DUAL TOILET PAPER HOLDER HD-04 WALL-MOUNTED ROBE HOOK HD-04.1 TOWEL BAR HD-05.2 SLIDING SHOWER DOOR HD-08 18" GRAB BAR HD-16 BULK AMENITY DISPENSER ATSHOWERS/TUBS HD-18 FOOT LEDGE FOR SHOWER HD-18.1 SOAP SHELF HD-21 BULK AMENITY DISPENSER AT LAVATORIES FFL EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV Revision Schedule Number Description Date MMAATVTVTVSD TVA-415B4 1 2 3 A-4242 XE1/2 D-G02 18' - 8" D-G03A GR-103 GR-105 GR-105 GR-KM GR-901 GR-900 11' - 0 1/2"7' - 7 3/4"12' - 5 3/4"13' - 11 1/4"6' - 0"W-G GR-400GR-400 GR-308 GR-201 GR-201 GR-908 GR-907 GR-308 GR-504 GR-906GR-911 GR-103 P3.2 GR-322 GR-902 GR-507 A-4243 BED 1 1 TABLE 1 1 1 4' - 6"4' - 6"6' - 10"1' - 5"1' - 0"5' - 1"1' - 5"GR-203 GR-203 PLAN ELEV DUPLEX OUTLET QUADPLEX OUTLET GFCI OUTLET CAT6, RJ45 INTERNET OUTLET TELEPHONE OUTLET WALL MOUNTED WIRELESS THERMOSTAT POWER OUTLET WITH USB PORTS CATV OUTLET ELECTRICAL SWITCH FLOOR OUTLET POWER AND SIGNAL LEGEND: POWER SUPPLY CEILING FIXTURE LEGEND: 6" RECESSED CAN DOWNLIGHT DECORATIVE FLUSH MOUNT LIGHT PENDENT TYPE SPRINKLERS SMOKE DETECTOR EXHAUST FAN / GRILLE LINEAR SURFACE MOUNTED CONTINUOUS LED SYSTEM W/ FIXED MOUNTING CLIPS & FROSTED LENS / 3 WATTS PER FOOT, MLV/FWD ELECTRICAL OUTLET HEIGHTS (U.N.O) TYPICAL OUTLET - 15" A.F.F TYPICAL ACCESSIBLE WALL OUTLET - 18" A.F.F BATHROOM VANITY OUTLET - 42" A.F.F TYP. KITCHEN OUTLET - 42" A.F.F ADA KITCHEN OUTLET - 46" A.F.F ADA BATHROOM VANITY OUTLET - 44" A.F.F ELECTRICAL SWITCH HEIGHTS (U.N.O) SWITCH - 44" A.F.F THERMOSTAT REMOTE - 48" A.F.F MAX TO TOP OF SWITCH JUNCTION BOX DOOR BELL HARDWIRED TO DOORBELL LIGHT - MOUNT @ 46" A.F.F TO CENTER OF BUTTON (FOR COMMUNICATIONS FEATURES ROOMS ONLY) SD 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216UNIT PLAN - KINGSTUDIO ADA MOBILITY A-415 FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 1/2" = 1'-0"2KING STUIO ADA MOBILITY REFLECTED CEILING PLAN Units 138, 238 (Roll-In), 338 (Tub) 1/2" = 1'-0" Reference: 1 / A-102 1KING STUDIO ADA MOBILITY CONSTRUCTION PLAN Units 138, 238 (Roll-In), 338 (Tub) 0'1' 2'4' SCALE: 1/2" = 1'-0" 2 5 2 2 2 KEYNOTES - UNIT PLANS 1 ALIGN 2 GENERAL CONTRACTOR TO COORDINATE W/ FURNITUREFABRICATOR WHERE NECESSARY TO PROVIDE PROPERBLOCKING IN WALL FOR ITEM KEYNOTED 3 NO FINISHES UNDER THE SHOWER PAN / TUB 4 NO FINISHES UNDER MILLWORK CABINETRY 5 TV AND MOUNT NOT TO PROJECT MORE THAN 4" FROMWALL 6 MOTORIZED BLINDS. PROVIDE JUNCTION BOX BEHINDVALENCE FOR POWER CONNECTION AND PERMANENTLYINSTALLED SWITCH ON WALL TO CONTROL BLINDS. 7 SWITCH CONTROLLING UNDER CABINET LIGHTING ATKITCHEN TO BE GANGED WITH LIGHTING AT ENTRY 8 SWITCH CONTROLLING GARBAGE DISPOSAL-REFER TOHADG FOR ACCESSIBLE ROOM REQ'S. 9 DEDICATED CIRCUIT FOR GARBAGE DISPOSAL 10 MASTER SWITCH 11 DEDICATED CIRCUIT FOR INDUCTION COOKTOP 12 DEDICATED CIRCUIT FOR DISHWASHER 13 DEDICATED CIRCUIT FOR REFRIGERATOR 14 ELECTRIC VANITY MIRROR - HARDWIRE FIXTURE TO WALL-CONTRACTOR TO VERIFY JBOX TYPE TO ENSURE PROPERINSTALLATION AND BACKING FOR ITEM KEYNOTED 15 DOORBELL AND DOORBELL ON/OFF SWITCH(COMMUNICATION FEATURES ROOMS ONLY)SIGNAGE ASREQ'D. 16 PLACE TV OUTLETS AND CONNECTIONS ON WALL OUTSIDEAREA OF BRACKET AND CONCEALED FROM VIEW BY TV 17 DEDICATED CIRCUIT FOR WASHER/DRYER. DIRECT VENTTO EXTERIOR FURNISHING SCHEDULE GUESTROOM FURNISHINGS GR-103 CHAIR - KITCHEN STOOL GR-105 SOFA - SLEEP BETWEEN ARMS GR-201 SCONCE - NIGHTSTAND GR-203 PENDANT LIGHT - PRODUCTIVITY TABLE GR-205 LAMP - FLOOR LAMP GR-308 NIGHTSTAND - REGULAR GR-312 TABLE - NESTING GR-314 TABLE - PRODUCTIVITY TABLE (STUDIO) GR-322 CLOSET - ACCESSIBLE KING STUDIO SUITE GR-327 VANITY - ACCESSIBLE SUITES GR-328 BATH CADDY - ACCESSIBLE SUITES GR-400 STATIC DRAPARY PANELS GR-403 ROLLER SHADE - GUESTROOMS (MANUAL,SHEER/BLACK-OUT, 8' W) GR-412 VALENCE FOR 8' WINDOW GR-503 ART- ENTRY GR-504 ART- SLEEPING/LIVING GR-505 WALL HOOK GR-507 MIRROR - ADA VANITY GR-800 KITCHENETTE - 1-BEDROOM GR-900 GUESTROOM REFRIGERATOR GR-901 GUESTROOM DISHWASHER GR-902 GUESTROOM COOKTOP - 2 BURNER GR-906GR-911 TELEVISION & TELEVISION MOUNT GR-907 CLOCK/RADIO GR-908 TELEPHONE - GUESTROOM GR-912 RECIRCULATING HOOD GR-913 COUNTERTOP MICROWAVE GR-KM BED - KING MOBILITY (GR-301, 304, 600, 602) PUBLIC AREA FURNISHINGS PA-502 ART - PUBLIC RESTROOM- WOMEN'S PLUMBING/MECHANICAL FIXTURES PF-01 TOILET - GUESTROOM PF-04 SHOWER BASE - 60" X 36" ADA ROLL-INSHOWER WITH EDGE TRENCH DRAIN PF-06 BATHTUB - 5' X 32" WITH SIDE LEDGE PF-07 LAVATORY - UNDERMOUNT, 20" X 14" PF-10 SHOWER HEAD - HIGH PF-12 SHOWER HEAD - HAND HELD ON SLIDE BAR PF-13 SHOWER/TUB VALVE & CONTROL PF-14 BATHTUB FILL FAUCET PF-15 FAUCET - LAVATORY PF-40 SINK - KITCHENETTE PF-41 FAUCET - KITCHENETTE PF-42 SINK - ADA KITCHENETTE TOILET ACCESSORIES HD-02 DUAL TOILET PAPER HOLDER- ADA HD-04 WALL-MOUNTED ROBE HOOK HD-04.1 TOWEL BAR HD-05 CURVED CURTAIN ROD AND SHOWERCURTAIN HD-08 18" GRAB BAR HD-09 24" GRAB BAR HD-10 42" GRAB BAR AT ADA BATHTUB HD-11 36" GRAB BAR HD-11.1 42" GRAB BAR HD-12 DOOR-MOUNTED ROBE HOOK HD-14.1 ROLL-IN SHOWER SEAT HD-16 BULK AMENITY DISPENSER ATSHOWERS/TUBS HD-18.1 SOAP SHELF HD-20 12" GRAB BAR HD-21 BULK AMENITY DISPENSER AT LAVATORIES EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV Revision Schedule Number Description Date TVTVTVA-415B4 1 2 3 A-4246 5 4 CPT-10 SF-01 WC-01 WC-01 WC-01 WC-01 WC-01 1 A-510 Sim 6 A-510 Sim 9 A-510 Sim 7 A-510 Sim 9' - 6 3/4" RES-01 CPT-01 CT-01 PLAN ELEV DUPLEX OUTLET QUADPLEX OUTLET GFCI OUTLET CAT6, RJ45 INTERNET OUTLET TELEPHONE OUTLET WALL MOUNTED WIRELESS THERMOSTAT POWER OUTLET WITH USB PORTS CATV OUTLET ELECTRICAL SWITCH FLOOR OUTLET POWER AND SIGNAL LEGEND: POWER SUPPLY CEILING FIXTURE LEGEND: 6" RECESSED CAN DOWNLIGHT DECORATIVE FLUSH MOUNT LIGHT PENDENT TYPE SPRINKLERS SMOKE DETECTOR EXHAUST FAN / GRILLE LINEAR SURFACE MOUNTED CONTINUOUS LED SYSTEM W/ FIXED MOUNTING CLIPS & FROSTED LENS / 3 WATTS PER FOOT, MLV/FWD ELECTRICAL OUTLET HEIGHTS (U.N.O) TYPICAL OUTLET - 15" A.F.F TYPICAL ACCESSIBLE WALL OUTLET - 18" A.F.F BATHROOM VANITY OUTLET - 42" A.F.F TYP. KITCHEN OUTLET - 42" A.F.F ADA KITCHEN OUTLET - 46" A.F.F ADA BATHROOM VANITY OUTLET - 44" A.F.F ELECTRICAL SWITCH HEIGHTS (U.N.O) SWITCH - 44" A.F.F THERMOSTAT REMOTE - 48" A.F.F MAX TO TOP OF SWITCH JUNCTION BOX DOOR BELL HARDWIRED TO DOORBELL LIGHT - MOUNT @ 46" A.F.F TO CENTER OF BUTTON (FOR COMMUNICATIONS FEATURES ROOMS ONLY) SD 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216UNIT PLAN - KINGSTUDIO ADA MOBILITY -ELEC, DATA & FLOORFINISH PLAN A-415A FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 1/2" = 1'-0"2KING STUIO ADA MOBILITY ELECTRICAL & DATA PLAN Units 138, 238, 338 1/2" = 1'-0"1KING STUIO ADA MOBILITY FLOOR & WALL PLAN Units 138, 238, 338 0'1' 2'4' SCALE: 1/2" = 1'-0" 3 15 12 8 9 11 13 7 10 16 14 KEYNOTES - UNIT PLANS 1 ALIGN 2 GENERAL CONTRACTOR TO COORDINATE W/ FURNITUREFABRICATOR WHERE NECESSARY TO PROVIDE PROPERBLOCKING IN WALL FOR ITEM KEYNOTED 3 NO FINISHES UNDER THE SHOWER PAN / TUB 4 NO FINISHES UNDER MILLWORK CABINETRY 5 TV AND MOUNT NOT TO PROJECT MORE THAN 4" FROMWALL 6 MOTORIZED BLINDS. PROVIDE JUNCTION BOX BEHINDVALENCE FOR POWER CONNECTION AND PERMANENTLYINSTALLED SWITCH ON WALL TO CONTROL BLINDS. 7 SWITCH CONTROLLING UNDER CABINET LIGHTING ATKITCHEN TO BE GANGED WITH LIGHTING AT ENTRY 8 SWITCH CONTROLLING GARBAGE DISPOSAL-REFER TOHADG FOR ACCESSIBLE ROOM REQ'S. 9 DEDICATED CIRCUIT FOR GARBAGE DISPOSAL 10 MASTER SWITCH 11 DEDICATED CIRCUIT FOR INDUCTION COOKTOP 12 DEDICATED CIRCUIT FOR DISHWASHER 13 DEDICATED CIRCUIT FOR REFRIGERATOR 14 ELECTRIC VANITY MIRROR - HARDWIRE FIXTURE TO WALL-CONTRACTOR TO VERIFY JBOX TYPE TO ENSURE PROPERINSTALLATION AND BACKING FOR ITEM KEYNOTED 15 DOORBELL AND DOORBELL ON/OFF SWITCH(COMMUNICATION FEATURES ROOMS ONLY)SIGNAGE ASREQ'D. 16 PLACE TV OUTLETS AND CONNECTIONS ON WALL OUTSIDEAREA OF BRACKET AND CONCEALED FROM VIEW BY TV 17 DEDICATED CIRCUIT FOR WASHER/DRYER. DIRECT VENTTO EXTERIOR FURNISHING SCHEDULE GUESTROOM FURNISHINGS GR-103 CHAIR - KITCHEN STOOL GR-105 SOFA - SLEEP BETWEEN ARMS GR-201 SCONCE - NIGHTSTAND GR-205 LAMP - FLOOR LAMP GR-308 NIGHTSTAND - REGULAR GR-312 TABLE - NESTING GR-314 TABLE - PRODUCTIVITY TABLE (STUDIO) GR-322 CLOSET - ACCESSIBLE KING STUDIO SUITE GR-327 VANITY - ACCESSIBLE SUITES GR-328 BATH CADDY - ACCESSIBLE SUITES GR-400 STATIC DRAPARY PANELS GR-503 ART- ENTRY GR-504 ART- SLEEPING/LIVING GR-507 MIRROR - ADA VANITY GR-800 KITCHENETTE - 1-BEDROOM GR-900 GUESTROOM REFRIGERATOR GR-901 GUESTROOM DISHWASHER GR-902 GUESTROOM COOKTOP - 2 BURNER GR-906GR-911 TELEVISION & TELEVISION MOUNT GR-907 CLOCK/RADIO GR-908 TELEPHONE - GUESTROOM GR-913 COUNTERTOP MICROWAVE GR-KM BED - KING MOBILITY (GR-301, 304, 600, 602) PLUMBING/MECHANICAL FIXTURES PF-01 TOILET - GUESTROOM PF-06 BATHTUB - 5' X 32" WITH SIDE LEDGE PF-07 LAVATORY - UNDERMOUNT, 20" X 14" PF-12 SHOWER HEAD - HAND HELD ON SLIDE BAR PF-13 SHOWER/TUB VALVE & CONTROL PF-14 BATHTUB FILL FAUCET PF-15 FAUCET - LAVATORY PF-42 SINK - ADA KITCHENETTE TOILET ACCESSORIES HD-02 DUAL TOILET PAPER HOLDER- ADA HD-04 WALL-MOUNTED ROBE HOOK HD-04.1 TOWEL BAR HD-08 18" GRAB BAR HD-09 24" GRAB BAR HD-10 42" GRAB BAR AT ADA BATHTUB HD-11 36" GRAB BAR HD-11.1 42" GRAB BAR HD-14.1 ROLL-IN SHOWER SEAT HD-16 BULK AMENITY DISPENSER ATSHOWERS/TUBS HD-18.1 SOAP SHELF HD-20 12" GRAB BAR HD-21 BULK AMENITY DISPENSER AT LAVATORIES EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV Revision Schedule Number Description Date TV5' - 0"GR-505 5' - 0"RB-01 WC-01 WD-01 WC-02 PT-03PL-02 WC-01 RB-01 EQ RB-01 EQ 6 GR-KM PA-502 D-G03AGR-322 1' - 1 1/2"1' - 6" WC-01 17 A-510 Sim RB-015' - 0"W-G GR-412 6' - 1 1/4"5' - 1"0' - 3" RB-01 WC-01 PT-03PL-024' - 2"WC-01 GFCI WC-01 D-G02 PLAN ELEV DUPLEX OUTLET QUADPLEX OUTLET GFCI OUTLET CAT6, RJ45 INTERNET OUTLET TELEPHONE OUTLET WALL MOUNTED WIRELESS THERMOSTAT POWER OUTLET WITH USB PORTS CATV OUTLET ELECTRICAL SWITCH FLOOR OUTLET POWER AND SIGNAL LEGEND: POWER SUPPLY CEILING FIXTURE LEGEND: 6" RECESSED CAN DOWNLIGHT DECORATIVE FLUSH MOUNT LIGHT PENDENT TYPE SPRINKLERS SMOKE DETECTOR EXHAUST FAN / GRILLE LINEAR SURFACE MOUNTED CONTINUOUS LED SYSTEM W/ FIXED MOUNTING CLIPS & FROSTED LENS / 3 WATTS PER FOOT, MLV/FWD ELECTRICAL OUTLET HEIGHTS (U.N.O) TYPICAL OUTLET - 15" A.F.F TYPICAL ACCESSIBLE WALL OUTLET - 18" A.F.F BATHROOM VANITY OUTLET - 42" A.F.F TYP. KITCHEN OUTLET - 42" A.F.F ADA KITCHEN OUTLET - 46" A.F.F ADA BATHROOM VANITY OUTLET - 44" A.F.F ELECTRICAL SWITCH HEIGHTS (U.N.O) SWITCH - 44" A.F.F THERMOSTAT REMOTE - 48" A.F.F MAX TO TOP OF SWITCH JUNCTION BOX DOOR BELL HARDWIRED TO DOORBELL LIGHT - MOUNT @ 46" A.F.F TO CENTER OF BUTTON (FOR COMMUNICATIONS FEATURES ROOMS ONLY) SD 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216UNIT INT. ELEVATIONS -KING STUDIO ADAMOBILITY A-415B FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 FFL FFL 1/2" = 1'-0" Reference: 1 / A-415 1KING STUIO ADA MOBILITY ELEVATION A Units 138, 238, 338 1/2" = 1'-0" Reference: 1 / A-415 2KING STUIO ADA MOBILITY ELEVATION B Units 138, 238, 338 1/2" = 1'-0" Reference: 1 / A-415 3KING STUIO ADA MOBILITY ELEVATION C Units 138, 238, 338 1/2" = 1'-0" Reference: 1 / A-415 4KING STUIO ADA MOBILITY ELEVATION D Units 138, 238, 338 0'1' 2'4' SCALE: 1/2" = 1'-0" FFL KEYNOTES - UNIT PLANS 1 ALIGN 2 GENERAL CONTRACTOR TO COORDINATE W/ FURNITUREFABRICATOR WHERE NECESSARY TO PROVIDE PROPERBLOCKING IN WALL FOR ITEM KEYNOTED 3 NO FINISHES UNDER THE SHOWER PAN / TUB 4 NO FINISHES UNDER MILLWORK CABINETRY 5 TV AND MOUNT NOT TO PROJECT MORE THAN 4" FROMWALL 6 MOTORIZED BLINDS. PROVIDE JUNCTION BOX BEHINDVALENCE FOR POWER CONNECTION AND PERMANENTLYINSTALLED SWITCH ON WALL TO CONTROL BLINDS. 7 SWITCH CONTROLLING UNDER CABINET LIGHTING ATKITCHEN TO BE GANGED WITH LIGHTING AT ENTRY 8 SWITCH CONTROLLING GARBAGE DISPOSAL-REFER TOHADG FOR ACCESSIBLE ROOM REQ'S. 9 DEDICATED CIRCUIT FOR GARBAGE DISPOSAL 10 MASTER SWITCH 11 DEDICATED CIRCUIT FOR INDUCTION COOKTOP 12 DEDICATED CIRCUIT FOR DISHWASHER 13 DEDICATED CIRCUIT FOR REFRIGERATOR 14 ELECTRIC VANITY MIRROR - HARDWIRE FIXTURE TO WALL-CONTRACTOR TO VERIFY JBOX TYPE TO ENSURE PROPERINSTALLATION AND BACKING FOR ITEM KEYNOTED 15 DOORBELL AND DOORBELL ON/OFF SWITCH(COMMUNICATION FEATURES ROOMS ONLY)SIGNAGE ASREQ'D. 16 PLACE TV OUTLETS AND CONNECTIONS ON WALL OUTSIDEAREA OF BRACKET AND CONCEALED FROM VIEW BY TV 17 DEDICATED CIRCUIT FOR WASHER/DRYER. DIRECT VENTTO EXTERIOR FURNISHING SCHEDULE GUESTROOM FURNISHINGS GR-103 CHAIR - KITCHEN STOOL GR-105 SOFA - SLEEP BETWEEN ARMS GR-201 SCONCE - NIGHTSTAND GR-203 PENDANT LIGHT - PRODUCTIVITY TABLE GR-205 LAMP - FLOOR LAMP GR-308 NIGHTSTAND - REGULAR GR-312 TABLE - NESTING GR-313 TABLE - ROUND SIDE TABLE GR-314 TABLE - PRODUCTIVITY TABLE (STUDIO) GR-321 CLOSET - KING STUDIO SUITE GR-322 CLOSET - ACCESSIBLE KING STUDIO SUITE GR-327 VANITY - ACCESSIBLE SUITES GR-328 BATH CADDY - ACCESSIBLE SUITES GR-400 STATIC DRAPARY PANELS GR-403 ROLLER SHADE - GUESTROOMS (MANUAL,SHEER/BLACK-OUT, 8' W) GR-412 VALENCE FOR 8' WINDOW GR-503 ART- ENTRY GR-504 ART- SLEEPING/LIVING GR-505 WALL HOOK GR-507 MIRROR - ADA VANITY GR-800 KITCHENETTE - 1-BEDROOM GR-900 GUESTROOM REFRIGERATOR GR-901 GUESTROOM DISHWASHER GR-902 GUESTROOM COOKTOP - 2 BURNER GR-904 GARBAGE DISPOSAL 1/3HP GR-905 MICROWAVE- WITH RECIRCULATING HOOD GR-906GR-911 TELEVISION & TELEVISION MOUNT GR-907 CLOCK/RADIO GR-908 TELEPHONE - GUESTROOM GR-912 RECIRCULATING HOOD GR-913 COUNTERTOP MICROWAVE GR-KM BED - KING MOBILITY (GR-301, 304, 600, 602) PUBLIC AREA FURNISHINGS PA-502 ART - PUBLIC RESTROOM- WOMEN'S OWNER SPECIFIED - OWNER FURNISHED OP-706 FIRE EXTINGUISHER CABINET PLUMBING/MECHANICAL FIXTURES PF-01 TOILET - GUESTROOM PF-03 SHOWER BASE - 60" X 36" WITH LINEARDRAIN PF-06 BATHTUB - 5' X 32" WITH SIDE LEDGE PF-07 LAVATORY - UNDERMOUNT, 20" X 14" PF-10 SHOWER HEAD - HIGH PF-11 SHOWER HEAD - 2 IN 1 PF-12 SHOWER HEAD - HAND HELD ON SLIDE BAR PF-13 SHOWER/TUB VALVE & CONTROL PF-14 BATHTUB FILL FAUCET PF-15 FAUCET - LAVATORY PF-40 SINK - KITCHENETTE PF-41 FAUCET - KITCHENETTE PF-42 SINK - ADA KITCHENETTE TOILET ACCESSORIES HD-02 DUAL TOILET PAPER HOLDER- ADA HD-04 WALL-MOUNTED ROBE HOOK HD-04.1 TOWEL BAR HD-05 CURVED CURTAIN ROD AND SHOWERCURTAIN HD-05.2 SLIDING SHOWER DOOR HD-08 18" GRAB BAR HD-09 24" GRAB BAR HD-10 42" GRAB BAR AT ADA BATHTUB HD-11 36" GRAB BAR HD-11.1 42" GRAB BAR HD-12 DOOR-MOUNTED ROBE HOOK HD-14.1 ROLL-IN SHOWER SEAT HD-16 BULK AMENITY DISPENSER ATSHOWERS/TUBS HD-18 FOOT LEDGE FOR SHOWER HD-18.1 SOAP SHELF HD-20 12" GRAB BAR HD-21 BULK AMENITY DISPENSER AT LAVATORIES EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV Revision Schedule Number Description Date MMAATVTVSD TV A-416B4 1 2 3 XE1/2 XE1/2 XE1/2 P3.2 4' - 6" D-G01 12' - 2 1/4"6' - 5 3/4"6' - 5 1/4"5' - 3 1/2"14' - 8 1/4"6' - 0" W-G D-G02 18' - 8"26' - 2"GR-400GR-400 GR-308 GR-201 GR-907 GR-908 GR-308GR-201 GR-504 GR-105GR-312 GR-205 GR-103 GR-103 GR-318 GR-321 GR-906GR-911 GR-506 4' - 6"4' - 6" CL-B8' - 0" CL-B27' - 6" CL-A8' - 0" OF BED EQ EQ OF TABLE 1' - 6"1' - 5"1' - 5"2' - 8" 1 1 1 114' - 0"CL-B27' - 6" PLAN ELEV DUPLEX OUTLET QUADPLEX OUTLET GFCI OUTLET CAT6, RJ45 INTERNET OUTLET TELEPHONE OUTLET WALL MOUNTED WIRELESS THERMOSTAT POWER OUTLET WITH USB PORTS CATV OUTLET ELECTRICAL SWITCH FLOOR OUTLET POWER AND SIGNAL LEGEND: POWER SUPPLY CEILING FIXTURE LEGEND: 6" RECESSED CAN DOWNLIGHT DECORATIVE FLUSH MOUNT LIGHT PENDENT TYPE SPRINKLERS SMOKE DETECTOR EXHAUST FAN / GRILLE LINEAR SURFACE MOUNTED CONTINUOUS LED SYSTEM W/ FIXED MOUNTING CLIPS & FROSTED LENS / 3 WATTS PER FOOT, MLV/FWD ELECTRICAL OUTLET HEIGHTS (U.N.O) TYPICAL OUTLET - 15" A.F.F TYPICAL ACCESSIBLE WALL OUTLET - 18" A.F.F BATHROOM VANITY OUTLET - 42" A.F.F TYP. KITCHEN OUTLET - 42" A.F.F ADA KITCHEN OUTLET - 46" A.F.F ADA BATHROOM VANITY OUTLET - 44" A.F.F ELECTRICAL SWITCH HEIGHTS (U.N.O) SWITCH - 44" A.F.F THERMOSTAT REMOTE - 48" A.F.F MAX TO TOP OF SWITCH JUNCTION BOX DOOR BELL HARDWIRED TO DOORBELL LIGHT - MOUNT @ 46" A.F.F TO CENTER OF BUTTON (FOR COMMUNICATIONS FEATURES ROOMS ONLY) SD 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216UNIT PLAN - KINGSTUDIO ENLARGED A-416 FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 1/2" = 1'-0" Reference: 1 / A-104 1KING STUDIO ENLARGED UNIT CONSTRUCTION PLAN Units 438, 538 1/2" = 1'-0" Reference: 1 / x-114 2KING STUDIO ENLARGED UNIT REFLECTED CEILING PLAN Units 438, 538 0'1' 2'4' SCALE: 1/2" = 1'-0" KEYNOTES - UNIT PLANS 1 ALIGN 2 GENERAL CONTRACTOR TO COORDINATE W/ FURNITUREFABRICATOR WHERE NECESSARY TO PROVIDE PROPERBLOCKING IN WALL FOR ITEM KEYNOTED 3 NO FINISHES UNDER THE SHOWER PAN / TUB 4 NO FINISHES UNDER MILLWORK CABINETRY 5 TV AND MOUNT NOT TO PROJECT MORE THAN 4" FROMWALL 6 MOTORIZED BLINDS. PROVIDE JUNCTION BOX BEHINDVALENCE FOR POWER CONNECTION AND PERMANENTLYINSTALLED SWITCH ON WALL TO CONTROL BLINDS. 7 SWITCH CONTROLLING UNDER CABINET LIGHTING ATKITCHEN TO BE GANGED WITH LIGHTING AT ENTRY 8 SWITCH CONTROLLING GARBAGE DISPOSAL-REFER TOHADG FOR ACCESSIBLE ROOM REQ'S. 9 DEDICATED CIRCUIT FOR GARBAGE DISPOSAL 10 MASTER SWITCH 11 DEDICATED CIRCUIT FOR INDUCTION COOKTOP 12 DEDICATED CIRCUIT FOR DISHWASHER 13 DEDICATED CIRCUIT FOR REFRIGERATOR 14 ELECTRIC VANITY MIRROR - HARDWIRE FIXTURE TO WALL-CONTRACTOR TO VERIFY JBOX TYPE TO ENSURE PROPERINSTALLATION AND BACKING FOR ITEM KEYNOTED 15 DOORBELL AND DOORBELL ON/OFF SWITCH(COMMUNICATION FEATURES ROOMS ONLY)SIGNAGE ASREQ'D. 16 PLACE TV OUTLETS AND CONNECTIONS ON WALL OUTSIDEAREA OF BRACKET AND CONCEALED FROM VIEW BY TV 17 DEDICATED CIRCUIT FOR WASHER/DRYER. DIRECT VENTTO EXTERIOR 2 5 2 2 2 FURNISHING SCHEDULE GUESTROOM FURNISHINGS GR-103 CHAIR - KITCHEN STOOL GR-105 SOFA - SLEEP BETWEEN ARMS GR-201 SCONCE - NIGHTSTAND GR-203 PENDANT LIGHT - PRODUCTIVITY TABLE GR-205 LAMP - FLOOR LAMP GR-308 NIGHTSTAND - REGULAR GR-312 TABLE - NESTING GR-314 TABLE - PRODUCTIVITY TABLE (STUDIO) GR-318 DRESSER - HIGHBOY GR-321 CLOSET - KING STUDIO SUITE GR-326 VANITY - STUDIO AND 1-BEDROOM SUITES GR-400 STATIC DRAPARY PANELS GR-403 ROLLER SHADE - GUESTROOMS (MANUAL,SHEER/BLACK-OUT, 8' W) GR-412 VALENCE FOR 8' WINDOW GR-503 ART- ENTRY GR-504 ART- SLEEPING/LIVING GR-506 MIRROR - GUESTROOM FULL LENGTH GR-800 KITCHENETTE - 1-BEDROOM GR-900 GUESTROOM REFRIGERATOR GR-901 GUESTROOM DISHWASHER GR-902 GUESTROOM COOKTOP - 2 BURNER GR-904 GARBAGE DISPOSAL 1/3HP GR-905 MICROWAVE- WITH RECIRCULATING HOOD GR-906GR-911 TELEVISION & TELEVISION MOUNT GR-907 CLOCK/RADIO GR-908 TELEPHONE - GUESTROOM GR-KS BED - KING (GR-301, 303, 600) PLUMBING/MECHANICAL FIXTURES PF-01 TOILET - GUESTROOM PF-03 SHOWER BASE - 60" X 36" WITH LINEARDRAIN PF-07 LAVATORY - UNDERMOUNT, 20" X 14" PF-11 SHOWER HEAD - 2 IN 1 PF-13 SHOWER/TUB VALVE & CONTROL PF-15 FAUCET - LAVATORY PF-40 SINK - KITCHENETTE PF-41 FAUCET - KITCHENETTE TOILET ACCESSORIES HD-01 DUAL TOILET PAPER HOLDER HD-04 WALL-MOUNTED ROBE HOOK HD-04.1 TOWEL BAR HD-05.2 SLIDING SHOWER DOOR HD-08 18" GRAB BAR HD-16 BULK AMENITY DISPENSER ATSHOWERS/TUBS HD-18 FOOT LEDGE FOR SHOWER HD-18.1 SOAP SHELF HD-21 BULK AMENITY DISPENSER AT LAVATORIES EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV Revision Schedule Number Description Date TVTVTV A-416B4 1 2 3 SF-01 WC-01 WC-01 WC-01 WC-01 WC-01 CPT-10 RES-01 CPT-01 CT-01 6 A-510 Sim 7 A-510 Sim FULL TILEFULL TILE 9 A-510 Sim 1 A-510 Sim FULL TILE PLAN ELEV DUPLEX OUTLET QUADPLEX OUTLET GFCI OUTLET CAT6, RJ45 INTERNET OUTLET TELEPHONE OUTLET WALL MOUNTED WIRELESS THERMOSTAT POWER OUTLET WITH USB PORTS CATV OUTLET ELECTRICAL SWITCH FLOOR OUTLET POWER AND SIGNAL LEGEND: POWER SUPPLY CEILING FIXTURE LEGEND: 6" RECESSED CAN DOWNLIGHT DECORATIVE FLUSH MOUNT LIGHT PENDENT TYPE SPRINKLERS SMOKE DETECTOR EXHAUST FAN / GRILLE LINEAR SURFACE MOUNTED CONTINUOUS LED SYSTEM W/ FIXED MOUNTING CLIPS & FROSTED LENS / 3 WATTS PER FOOT, MLV/FWD ELECTRICAL OUTLET HEIGHTS (U.N.O) TYPICAL OUTLET - 15" A.F.F TYPICAL ACCESSIBLE WALL OUTLET - 18" A.F.F BATHROOM VANITY OUTLET - 42" A.F.F TYP. KITCHEN OUTLET - 42" A.F.F ADA KITCHEN OUTLET - 46" A.F.F ADA BATHROOM VANITY OUTLET - 44" A.F.F ELECTRICAL SWITCH HEIGHTS (U.N.O) SWITCH - 44" A.F.F THERMOSTAT REMOTE - 48" A.F.F MAX TO TOP OF SWITCH JUNCTION BOX DOOR BELL HARDWIRED TO DOORBELL LIGHT - MOUNT @ 46" A.F.F TO CENTER OF BUTTON (FOR COMMUNICATIONS FEATURES ROOMS ONLY) SD 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216UNIT PLAN - KINGSTUDIO ENLARGED -ELEC, DATA & FLOORFINISH PLAN A-416A FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 1/2" = 1'-0"1KING STUDIO ENLARGED UNIT ELECTRICAL & DATA PLAN Units 438, 538 1/2" = 1'-0"2KING STUDIO ENLARGED UNIT FLOOR & WALL FINISH PLAN Units 438, 538 0'1' 2'4' SCALE: 1/2" = 1'-0" 3 15 12 8 9 11 13 7 10 16 14 KEYNOTES - UNIT PLANS 1 ALIGN 2 GENERAL CONTRACTOR TO COORDINATE W/ FURNITUREFABRICATOR WHERE NECESSARY TO PROVIDE PROPERBLOCKING IN WALL FOR ITEM KEYNOTED 3 NO FINISHES UNDER THE SHOWER PAN / TUB 4 NO FINISHES UNDER MILLWORK CABINETRY 5 TV AND MOUNT NOT TO PROJECT MORE THAN 4" FROMWALL 6 MOTORIZED BLINDS. PROVIDE JUNCTION BOX BEHINDVALENCE FOR POWER CONNECTION AND PERMANENTLYINSTALLED SWITCH ON WALL TO CONTROL BLINDS. 7 SWITCH CONTROLLING UNDER CABINET LIGHTING ATKITCHEN TO BE GANGED WITH LIGHTING AT ENTRY 8 SWITCH CONTROLLING GARBAGE DISPOSAL-REFER TOHADG FOR ACCESSIBLE ROOM REQ'S. 9 DEDICATED CIRCUIT FOR GARBAGE DISPOSAL 10 MASTER SWITCH 11 DEDICATED CIRCUIT FOR INDUCTION COOKTOP 12 DEDICATED CIRCUIT FOR DISHWASHER 13 DEDICATED CIRCUIT FOR REFRIGERATOR 14 ELECTRIC VANITY MIRROR - HARDWIRE FIXTURE TO WALL-CONTRACTOR TO VERIFY JBOX TYPE TO ENSURE PROPERINSTALLATION AND BACKING FOR ITEM KEYNOTED 15 DOORBELL AND DOORBELL ON/OFF SWITCH(COMMUNICATION FEATURES ROOMS ONLY)SIGNAGE ASREQ'D. 16 PLACE TV OUTLETS AND CONNECTIONS ON WALL OUTSIDEAREA OF BRACKET AND CONCEALED FROM VIEW BY TV 17 DEDICATED CIRCUIT FOR WASHER/DRYER. DIRECT VENTTO EXTERIOR FURNISHING SCHEDULE GUESTROOM FURNISHINGS GR-103 CHAIR - KITCHEN STOOL GR-105 SOFA - SLEEP BETWEEN ARMS GR-201 SCONCE - NIGHTSTAND GR-205 LAMP - FLOOR LAMP GR-308 NIGHTSTAND - REGULAR GR-312 TABLE - NESTING GR-314 TABLE - PRODUCTIVITY TABLE (STUDIO) GR-318 DRESSER - HIGHBOY GR-321 CLOSET - KING STUDIO SUITE GR-326 VANITY - STUDIO AND 1-BEDROOM SUITES GR-400 STATIC DRAPARY PANELS GR-504 ART- SLEEPING/LIVING GR-506 MIRROR - GUESTROOM FULL LENGTH GR-800 KITCHENETTE - 1-BEDROOM GR-900 GUESTROOM REFRIGERATOR GR-901 GUESTROOM DISHWASHER GR-902 GUESTROOM COOKTOP - 2 BURNER GR-904 GARBAGE DISPOSAL 1/3HP GR-906GR-911 TELEVISION & TELEVISION MOUNT GR-907 CLOCK/RADIO GR-908 TELEPHONE - GUESTROOM GR-KS BED - KING (GR-301, 303, 600) PLUMBING/MECHANICAL FIXTURES PF-01 TOILET - GUESTROOM PF-03 SHOWER BASE - 60" X 36" WITH LINEARDRAIN PF-07 LAVATORY - UNDERMOUNT, 20" X 14" PF-11 SHOWER HEAD - 2 IN 1 PF-13 SHOWER/TUB VALVE & CONTROL PF-15 FAUCET - LAVATORY PF-40 SINK - KITCHENETTE PF-41 FAUCET - KITCHENETTE TOILET ACCESSORIES HD-01 DUAL TOILET PAPER HOLDER HD-04.1 TOWEL BAR HD-05.2 SLIDING SHOWER DOOR HD-08 18" GRAB BAR HD-16 BULK AMENITY DISPENSER ATSHOWERS/TUBS HD-18 FOOT LEDGE FOR SHOWER HD-18.1 SOAP SHELF HD-21 BULK AMENITY DISPENSER AT LAVATORIES EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV Revision Schedule Number Description Date TV5' - 0"2' - 3" RB-01 WC-01 PT-11PL-01 WC-01 5' - 2"2' - 2" RB-01 WC-01 RB-01 PL-02PT-03 D-G03 GR-503 GR-KS GR-318 SF-01 GR-412 W-G 16 A-510 Sim RB-01 GR-403 GR-400 4' - 2"3' - 5 1/2" 0' - 3"5' - 1"RB-01 WC-01 PT-03PL-02 WC-01 D-G02 PLAN ELEV DUPLEX OUTLET QUADPLEX OUTLET GFCI OUTLET CAT6, RJ45 INTERNET OUTLET TELEPHONE OUTLET WALL MOUNTED WIRELESS THERMOSTAT POWER OUTLET WITH USB PORTS CATV OUTLET ELECTRICAL SWITCH FLOOR OUTLET POWER AND SIGNAL LEGEND: POWER SUPPLY CEILING FIXTURE LEGEND: 6" RECESSED CAN DOWNLIGHT DECORATIVE FLUSH MOUNT LIGHT PENDENT TYPE SPRINKLERS SMOKE DETECTOR EXHAUST FAN / GRILLE LINEAR SURFACE MOUNTED CONTINUOUS LED SYSTEM W/ FIXED MOUNTING CLIPS & FROSTED LENS / 3 WATTS PER FOOT, MLV/FWD ELECTRICAL OUTLET HEIGHTS (U.N.O) TYPICAL OUTLET - 15" A.F.F TYPICAL ACCESSIBLE WALL OUTLET - 18" A.F.F BATHROOM VANITY OUTLET - 42" A.F.F TYP. KITCHEN OUTLET - 42" A.F.F ADA KITCHEN OUTLET - 46" A.F.F ADA BATHROOM VANITY OUTLET - 44" A.F.F ELECTRICAL SWITCH HEIGHTS (U.N.O) SWITCH - 44" A.F.F THERMOSTAT REMOTE - 48" A.F.F MAX TO TOP OF SWITCH JUNCTION BOX DOOR BELL HARDWIRED TO DOORBELL LIGHT - MOUNT @ 46" A.F.F TO CENTER OF BUTTON (FOR COMMUNICATIONS FEATURES ROOMS ONLY) SD 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216UNIT INT. ELEVATIONS -KING STUDIOENLARGED A-416B FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 FFL FFL 1/2" = 1'-0" Reference: 1 / A-416 1KING STUDIO ENLARGED ELEVATION A Units 438, 538 1/2" = 1'-0" Reference: 1 / A-416 2KING STUDIO ENLARGED ELEVATION B Units 438, 538 1/2" = 1'-0" Reference: 1 / A-416 3KING STUDIO ENLARGED ELEVATION C Units 438, 538 1/2" = 1'-0" Reference: 1 / A-416 4KING STUDIO ENLARGED ELEVATION D Units 438, 538 FFL KEYNOTES - UNIT PLANS 1 ALIGN 2 GENERAL CONTRACTOR TO COORDINATE W/ FURNITUREFABRICATOR WHERE NECESSARY TO PROVIDE PROPERBLOCKING IN WALL FOR ITEM KEYNOTED 3 NO FINISHES UNDER THE SHOWER PAN / TUB 4 NO FINISHES UNDER MILLWORK CABINETRY 5 TV AND MOUNT NOT TO PROJECT MORE THAN 4" FROMWALL 6 MOTORIZED BLINDS. PROVIDE JUNCTION BOX BEHINDVALENCE FOR POWER CONNECTION AND PERMANENTLYINSTALLED SWITCH ON WALL TO CONTROL BLINDS. 7 SWITCH CONTROLLING UNDER CABINET LIGHTING ATKITCHEN TO BE GANGED WITH LIGHTING AT ENTRY 8 SWITCH CONTROLLING GARBAGE DISPOSAL-REFER TOHADG FOR ACCESSIBLE ROOM REQ'S. 9 DEDICATED CIRCUIT FOR GARBAGE DISPOSAL 10 MASTER SWITCH 11 DEDICATED CIRCUIT FOR INDUCTION COOKTOP 12 DEDICATED CIRCUIT FOR DISHWASHER 13 DEDICATED CIRCUIT FOR REFRIGERATOR 14 ELECTRIC VANITY MIRROR - HARDWIRE FIXTURE TO WALL-CONTRACTOR TO VERIFY JBOX TYPE TO ENSURE PROPERINSTALLATION AND BACKING FOR ITEM KEYNOTED 15 DOORBELL AND DOORBELL ON/OFF SWITCH(COMMUNICATION FEATURES ROOMS ONLY)SIGNAGE ASREQ'D. 16 PLACE TV OUTLETS AND CONNECTIONS ON WALL OUTSIDEAREA OF BRACKET AND CONCEALED FROM VIEW BY TV 17 DEDICATED CIRCUIT FOR WASHER/DRYER. DIRECT VENTTO EXTERIOR FURNISHING SCHEDULE GUESTROOM FURNISHINGS GR-105 SOFA - SLEEP BETWEEN ARMS GR-201 SCONCE - NIGHTSTAND GR-203 PENDANT LIGHT - PRODUCTIVITY TABLE GR-205 LAMP - FLOOR LAMP GR-308 NIGHTSTAND - REGULAR GR-312 TABLE - NESTING GR-314 TABLE - PRODUCTIVITY TABLE (STUDIO) GR-318 DRESSER - HIGHBOY GR-321 CLOSET - KING STUDIO SUITE GR-326 VANITY - STUDIO AND 1-BEDROOM SUITES GR-400 STATIC DRAPARY PANELS GR-403 ROLLER SHADE - GUESTROOMS (MANUAL,SHEER/BLACK-OUT, 8' W) GR-412 VALENCE FOR 8' WINDOW GR-503 ART- ENTRY GR-504 ART- SLEEPING/LIVING GR-506 MIRROR - GUESTROOM FULL LENGTH GR-800 KITCHENETTE - 1-BEDROOM GR-900 GUESTROOM REFRIGERATOR GR-901 GUESTROOM DISHWASHER GR-902 GUESTROOM COOKTOP - 2 BURNER GR-904 GARBAGE DISPOSAL 1/3HP GR-905 MICROWAVE- WITH RECIRCULATING HOOD GR-906GR-911 TELEVISION & TELEVISION MOUNT GR-907 CLOCK/RADIO GR-908 TELEPHONE - GUESTROOM GR-KS BED - KING (GR-301, 303, 600) OWNER SPECIFIED - OWNER FURNISHED OP-706 FIRE EXTINGUISHER CABINET PLUMBING/MECHANICAL FIXTURES PF-01 TOILET - GUESTROOM PF-03 SHOWER BASE - 60" X 36" WITH LINEARDRAIN PF-07 LAVATORY - UNDERMOUNT, 20" X 14" PF-11 SHOWER HEAD - 2 IN 1 PF-13 SHOWER/TUB VALVE & CONTROL PF-15 FAUCET - LAVATORY PF-40 SINK - KITCHENETTE PF-41 FAUCET - KITCHENETTE TOILET ACCESSORIES HD-01 DUAL TOILET PAPER HOLDER HD-04 WALL-MOUNTED ROBE HOOK HD-04.1 TOWEL BAR HD-05.2 SLIDING SHOWER DOOR HD-08 18" GRAB BAR HD-16 BULK AMENITY DISPENSER ATSHOWERS/TUBS HD-18 FOOT LEDGE FOR SHOWER HD-18.1 SOAP SHELF HD-21 BULK AMENITY DISPENSER AT LAVATORIES 0'1' 2'4' SCALE: 1/2" = 1'-0" EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV Revision Schedule Number Description Date W/DW/DM A A M TVTVSD SD SD SD TV A-417B5 1 2 4 A-417B 6 7 8 9 D-G03 D-G03 D-G05 D-G01 D-G04 XE1/2 P1.2 P1.1 P1.1 XE1/2 P3.1 P3.1 12' - 8 1/4"5' - 11"6' - 6 1/2"12' - 3"2' - 1"2' - 0"3' - 2 1/2" 13' - 2 1/4"4' - 10 3/4"6' - 10" GR-323 GR-314 GR-504 GR-908 GR-308 GR-907 GR-201 GR-KS GR-317 GR-906GR-911 GR-308 GR-201 GR-103GR-103 GR-103GR-103 GR-108 GR-312 GR-316 GR-508 GR-326 GR-901 GR-903 GR-900 1' - 10 3/4" GR-400GR-400 XE1/2 A-417B3 GR-506 GR-906GR-911 D-G02 CL-B8' - 0" CL-B27' - 6" CL-B8' - 0" CL-B8' - 0" CL-B27' - 6" CL-A8' - 0" GR-410GR-400 GR-400 EQEQ3' - 1"1' - 3" 1' - 3"2' - 2"5' - 10 1/4"1' - 4"1' - 0"EQ EQ6' - 0"EQ EQ 1' - 5"EQEQEQ EQ 1' - 0"1' - 0" 1 1 1 1 1 1 1 1' - 5"1 PLANELEV DUPLEX OUTLET QUADPLEX OUTLET GFCI OUTLET CAT6, RJ45 INTERNET OUTLET TELEPHONE OUTLET WALL MOUNTED WIRELESS THERMOSTAT POWER OUTLET WITH USB PORTS CATV OUTLET ELECTRICAL SWITCH FLOOR OUTLET POWER AND SIGNAL LEGEND: POWER SUPPLY JUNCTION BOX DOOR BELL HARDWIRED TO DOORBELL LIGHT - MOUNT @ 46" A.F.F TO CENTER OF BUTTON (FOR COMMUNICATIONS FEATURES ROOMS ONLY) CEILING FIXTURE LEGEND: 6" RECESSED CAN DOWNLIGHT DECORATIVE FLUSH MOUNT LIGHT PENDENT TYPE SPRINKLERS SMOKE DETECTOR EXHAUST FAN / GRILLE LINEAR SURFACE MOUNTED CONTINUOUS LED SYSTEM W/ FIXED MOUNTING CLIPS & FROSTED LENS / 3 WATTS PER FOOT, MLV/FWD ELECTRICAL OUTLET HEIGHTS (U.N.O) TYPICAL OUTLET - 15" A.F.F TYPICAL ACCESSIBLE WALL OUTLET - 18" A.F.F BATHROOM VANITY OUTLET - 42" A.F.F TYP. KITCHEN OUTLET - 42" A.F.F ADA KITCHEN OUTLET - 46" A.F.F ADA BATHROOM VANITY OUTLET - 44" A.F.F ELECTRICAL SWITCH HEIGHTS (U.N.O) SWITCH - 44" A.F.F THERMOSTAT REMOTE - 48" A.F.F MAX TO TOP OF SWITCH SD 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216UNIT PLAN - KING1-BEDROOM A-417 FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 1/2" = 1'-0" Reference: 1 / A-102 1KING 1-BEDROOM UNIT CONSTRUCTION PLAN Units x02 1/2" = 1'-0"2 KING 1-BEDROOM UNIT REFLECTED CEILING PLAN Units x02 0'1' 2'4' SCALE: 1/2" = 1'-0" 2 5 2 2 2 5 2 2 FURNISHING SCHEDULE GUESTROOM FURNISHINGS GR-103 CHAIR - KITCHEN STOOL GR-108 SOFA - SECTIONAL SLEEPER GR-201 SCONCE - NIGHTSTAND GR-203 PENDANT LIGHT - PRODUCTIVITY TABLE GR-204 CEILING LIGHT - 1-BEDROOM SUITE GR-205 LAMP - FLOOR LAMP GR-308 NIGHTSTAND - REGULAR GR-312 TABLE - NESTING GR-314 TABLE - PRODUCTIVITY TABLE (STUDIO) GR-316 CONSOLE - LIVING ROOM (1-BEDROOM) GR-317 DRESSER - BEDROOM (1-BEDROOM) GR-323 CLOSET - KING 1-BEDROOM SUITE GR-326 VANITY - STUDIO AND 1-BEDROOM SUITES GR-400 STATIC DRAPARY PANELS GR-403 ROLLER SHADE - GUESTROOMS (MANUAL,SHEER/BLACK-OUT, 8' W) GR-410 VALENCE FOR 5' WINDOW GR-413 VALENCE FOR 5' WINDOW - ONE DRAPERYPANEL GR-504 ART- SLEEPING/LIVING GR-505 WALL HOOK FURNISHING SCHEDULE GR-506 MIRROR - GUESTROOM FULL LENGTH GR-508 MIRROR - GUESTROOM VANITY GR-800 KITCHENETTE - 1-BEDROOM GR-900 GUESTROOM REFRIGERATOR GR-901 GUESTROOM DISHWASHER GR-903 GUESTROOM COOKTOP - 4 BURNER GR-904 GARBAGE DISPOSAL 1/3HP GR-905 MICROWAVE- WITH RECIRCULATING HOOD GR-906GR-911 TELEVISION & TELEVISION MOUNT GR-907 CLOCK/RADIO GR-908 TELEPHONE - GUESTROOM GR-909/910 GUESTROOM STACKED WASHER/DRYER GR-KS BED - KING (GR-301, 303, 600) HILTON SPECIFIED - OWNER FURNISHED OF-702A CHAIR - BALCONY CHAIR OF-705 TABLE - 17" D OUTDOOR SIDE TABLE OWNER SPECIFIED - OWNER FURNISHED FURNISHING SCHEDULE OP-706 FIRE EXTINGUISHER CABINET PLUMBING/MECHANICAL FIXTURES PF-01 TOILET - GUESTROOM PF-03 SHOWER BASE - 60" X 36" WITH LINEARDRAIN PF-07 LAVATORY - UNDERMOUNT, 20" X 14" PF-11 SHOWER HEAD - 2 IN 1 PF-13 SHOWER/TUB VALVE & CONTROL PF-15 FAUCET - LAVATORY PF-40 SINK - KITCHENETTE PF-41 FAUCET - KITCHENETTE TOILET ACCESSORIES HD-01 DUAL TOILET PAPER HOLDER HD-04 WALL-MOUNTED ROBE HOOK HD-04.1 TOWEL BAR HD-05.2 SLIDING SHOWER DOOR HD-08 18" GRAB BAR HD-16 BULK AMENITY DISPENSER ATSHOWERS/TUBS HD-18 FOOT LEDGE FOR SHOWER HD-18.1 SOAP SHELF HD-21 BULK AMENITY DISPENSER AT LAVATORIES KEYNOTES - UNIT PLANS 1 ALIGN 2 GENERAL CONTRACTOR TO COORDINATE W/ FURNITUREFABRICATOR WHERE NECESSARY TO PROVIDE PROPERBLOCKING IN WALL FOR ITEM KEYNOTED 3 NO FINISHES UNDER THE SHOWER PAN / TUB 4 NO FINISHES UNDER MILLWORK CABINETRY 5 TV AND MOUNT NOT TO PROJECT MORE THAN 4" FROMWALL 6 MOTORIZED BLINDS. PROVIDE JUNCTION BOX BEHINDVALENCE FOR POWER CONNECTION AND PERMANENTLYINSTALLED SWITCH ON WALL TO CONTROL BLINDS. 7 SWITCH CONTROLLING UNDER CABINET LIGHTING ATKITCHEN TO BE GANGED WITH LIGHTING AT ENTRY 8 SWITCH CONTROLLING GARBAGE DISPOSAL-REFER TOHADG FOR ACCESSIBLE ROOM REQ'S. 9 DEDICATED CIRCUIT FOR GARBAGE DISPOSAL 10 MASTER SWITCH 11 DEDICATED CIRCUIT FOR INDUCTION COOKTOP 12 DEDICATED CIRCUIT FOR DISHWASHER 13 DEDICATED CIRCUIT FOR REFRIGERATOR 14 ELECTRIC VANITY MIRROR - HARDWIRE FIXTURE TO WALL-CONTRACTOR TO VERIFY JBOX TYPE TO ENSURE PROPERINSTALLATION AND BACKING FOR ITEM KEYNOTED 15 DOORBELL AND DOORBELL ON/OFF SWITCH(COMMUNICATION FEATURES ROOMS ONLY)SIGNAGE ASREQ'D. 16 PLACE TV OUTLETS AND CONNECTIONS ON WALL OUTSIDEAREA OF BRACKET AND CONCEALED FROM VIEW BY TV 17 DEDICATED CIRCUIT FOR WASHER/DRYER. DIRECT VENTTO EXTERIOR EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV Revision Schedule Number Description Date W/DTVTVTV A-417B5 1 2 4 A-417B 6 7 8 9 A-417B3 CPT-02 CPT-01 RES-01 CT-01 CPT-10 7' - 0"11' - 0"FULL TILETILE FULL FULL TILE FULL TILEEQEQFULL TILESF-01 SF-01 SF-01 WC-01 WC-01 WC-01 WC-01 WC-01WC-01 WC-01 WC-01 WC-01 WC-01 6 A-510 Sim 8 A-510 Sim 9 A-510 Sim 1 A-510 Sim PLANELEV DUPLEX OUTLET QUADPLEX OUTLET GFCI OUTLET CAT6, RJ45 INTERNET OUTLET TELEPHONE OUTLET WALL MOUNTED WIRELESS THERMOSTAT POWER OUTLET WITH USB PORTS CATV OUTLET ELECTRICAL SWITCH FLOOR OUTLET POWER AND SIGNAL LEGEND: POWER SUPPLY JUNCTION BOX DOOR BELL HARDWIRED TO DOORBELL LIGHT - MOUNT @ 46" A.F.F TO CENTER OF BUTTON (FOR COMMUNICATIONS FEATURES ROOMS ONLY) CEILING FIXTURE LEGEND: 6" RECESSED CAN DOWNLIGHT DECORATIVE FLUSH MOUNT LIGHT PENDENT TYPE SPRINKLERS SMOKE DETECTOR EXHAUST FAN / GRILLE LINEAR SURFACE MOUNTED CONTINUOUS LED SYSTEM W/ FIXED MOUNTING CLIPS & FROSTED LENS / 3 WATTS PER FOOT, MLV/FWD ELECTRICAL OUTLET HEIGHTS (U.N.O) TYPICAL OUTLET - 15" A.F.F TYPICAL ACCESSIBLE WALL OUTLET - 18" A.F.F BATHROOM VANITY OUTLET - 42" A.F.F TYP. KITCHEN OUTLET - 42" A.F.F ADA KITCHEN OUTLET - 46" A.F.F ADA BATHROOM VANITY OUTLET - 44" A.F.F ELECTRICAL SWITCH HEIGHTS (U.N.O) SWITCH - 44" A.F.F THERMOSTAT REMOTE - 48" A.F.F MAX TO TOP OF SWITCH SD 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216UNIT PLAN - KING1-BEDROOM - ELEC,DATA & FLOOR FINISHPLAN A-417A FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 1/2" = 1'-0"1KING 1-BEDROOM UNIT ELECTRICAL & DATA PLAN Units x02 1/2" = 1'-0"2KING 1-BEDROOM UNIT FLOOR & WALL FINISH PLAN Units x02 3 1512 8 9 11 7 10 16 17 13 16 FURNISHING SCHEDULE GUESTROOM FURNISHINGS GR-103 CHAIR - KITCHEN STOOL GR-108 SOFA - SECTIONAL SLEEPER GR-201 SCONCE - NIGHTSTAND GR-205 LAMP - FLOOR LAMP GR-308 NIGHTSTAND - REGULAR GR-312 TABLE - NESTING GR-314 TABLE - PRODUCTIVITY TABLE (STUDIO) GR-316 CONSOLE - LIVING ROOM (1-BEDROOM) GR-317 DRESSER - BEDROOM (1-BEDROOM) GR-323 CLOSET - KING 1-BEDROOM SUITE GR-326 VANITY - STUDIO AND 1-BEDROOM SUITES GR-400 STATIC DRAPARY PANELS GR-504 ART- SLEEPING/LIVING GR-506 MIRROR - GUESTROOM FULL LENGTH GR-508 MIRROR - GUESTROOM VANITY GR-800 KITCHENETTE - 1-BEDROOM GR-900 GUESTROOM REFRIGERATOR GR-901 GUESTROOM DISHWASHER GR-903 GUESTROOM COOKTOP - 4 BURNER GR-904 GARBAGE DISPOSAL 1/3HP FURNISHING SCHEDULE GR-906GR-911 TELEVISION & TELEVISION MOUNT GR-907 CLOCK/RADIO GR-908 TELEPHONE - GUESTROOM GR-909/910 GUESTROOM STACKED WASHER/DRYER GR-KS BED - KING (GR-301, 303, 600) OWNER SPECIFIED - OWNER FURNISHED OP-706 FIRE EXTINGUISHER CABINET PLUMBING/MECHANICAL FIXTURES PF-01 TOILET - GUESTROOM PF-03 SHOWER BASE - 60" X 36" WITH LINEARDRAIN PF-07 LAVATORY - UNDERMOUNT, 20" X 14" PF-11 SHOWER HEAD - 2 IN 1 PF-13 SHOWER/TUB VALVE & CONTROL PF-15 FAUCET - LAVATORY PF-40 SINK - KITCHENETTE PF-41 FAUCET - KITCHENETTE FURNISHING SCHEDULE TOILET ACCESSORIES HD-01 DUAL TOILET PAPER HOLDER HD-04.1 TOWEL BAR HD-05.2 SLIDING SHOWER DOOR HD-08 18" GRAB BAR HD-16 BULK AMENITY DISPENSER ATSHOWERS/TUBS HD-18 FOOT LEDGE FOR SHOWER HD-18.1 SOAP SHELF HD-21 BULK AMENITY DISPENSER AT LAVATORIES KEYNOTES - UNIT PLANS 1 ALIGN 2 GENERAL CONTRACTOR TO COORDINATE W/ FURNITUREFABRICATOR WHERE NECESSARY TO PROVIDE PROPERBLOCKING IN WALL FOR ITEM KEYNOTED 3 NO FINISHES UNDER THE SHOWER PAN / TUB 4 NO FINISHES UNDER MILLWORK CABINETRY 5 TV AND MOUNT NOT TO PROJECT MORE THAN 4" FROMWALL 6 MOTORIZED BLINDS. PROVIDE JUNCTION BOX BEHINDVALENCE FOR POWER CONNECTION AND PERMANENTLYINSTALLED SWITCH ON WALL TO CONTROL BLINDS. 7 SWITCH CONTROLLING UNDER CABINET LIGHTING ATKITCHEN TO BE GANGED WITH LIGHTING AT ENTRY 8 SWITCH CONTROLLING GARBAGE DISPOSAL-REFER TOHADG FOR ACCESSIBLE ROOM REQ'S. 9 DEDICATED CIRCUIT FOR GARBAGE DISPOSAL 10 MASTER SWITCH 11 DEDICATED CIRCUIT FOR INDUCTION COOKTOP 12 DEDICATED CIRCUIT FOR DISHWASHER 13 DEDICATED CIRCUIT FOR REFRIGERATOR 14 ELECTRIC VANITY MIRROR - HARDWIRE FIXTURE TO WALL-CONTRACTOR TO VERIFY JBOX TYPE TO ENSURE PROPERINSTALLATION AND BACKING FOR ITEM KEYNOTED 15 DOORBELL AND DOORBELL ON/OFF SWITCH(COMMUNICATION FEATURES ROOMS ONLY)SIGNAGE ASREQ'D. 16 PLACE TV OUTLETS AND CONNECTIONS ON WALL OUTSIDEAREA OF BRACKET AND CONCEALED FROM VIEW BY TV 17 DEDICATED CIRCUIT FOR WASHER/DRYER. DIRECT VENTTO EXTERIOR 0'1' 2'4' SCALE: 1/2" = 1'-0" EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV Revision Schedule Number Description Date TV WD-01 WD-01 PC-04 WC-01 RB-01PT-03PT-03 W-K D-G04 GR-403GR-413 D-G05 WC-01 RB-01 WC-01 RB-01 PT-11PL-01 D-G01 PT-03PL-02 WC-01 2' - 1 1/2" RB-01 WD-01 WD-01 5' - 0"0' - 8" GR-505 3' - 4 1/2"5' - 1"0' - 9" D-G03D-G02 PT-03PL-02 4' - 2"4' - 1 1/4" SF-01 W-H RB-01 WD-01 SF-01 WD-01 WD-01 GR-413 GR-403 SF-01 RB-01 16 A-510 Sim GR-410GR-403 GR-400 4' - 2"6' - 0" WC-01 RB-01 GR-906GR-911 GR-317 4' - 2 3/4"5' - 0"WC-01 D-G05 PT-03 PT-03 RB-01 GR-504 WC-01 RB-10GR-KS GR-505 5' - 0"RB-01 PT-11 PL-01 WC-01 D-G01 PLAN ELEV DUPLEX OUTLET QUADPLEX OUTLET GFCI OUTLET CAT6, RJ45 INTERNET OUTLET TELEPHONE OUTLET WALL MOUNTED WIRELESS THERMOSTAT POWER OUTLET WITH USB PORTS CATV OUTLET ELECTRICAL SWITCH FLOOR OUTLET POWER AND SIGNAL LEGEND: POWER SUPPLY JUNCTION BOX DOOR BELL HARDWIRED TO DOORBELL LIGHT - MOUNT @ 46" A.F.F TO CENTER OF BUTTON (FOR COMMUNICATIONS FEATURES ROOMS ONLY) CEILING FIXTURE LEGEND: 6" RECESSED CAN DOWNLIGHT DECORATIVE FLUSH MOUNT LIGHT PENDENT TYPE SPRINKLERS SMOKE DETECTOR EXHAUST FAN / GRILLE LINEAR SURFACE MOUNTED CONTINUOUS LED SYSTEM W/ FIXED MOUNTING CLIPS & FROSTED LENS / 3 WATTS PER FOOT, MLV/FWD ELECTRICAL OUTLET HEIGHTS (U.N.O) TYPICAL OUTLET - 15" A.F.F TYPICAL ACCESSIBLE WALL OUTLET - 18" A.F.F BATHROOM VANITY OUTLET - 42" A.F.F TYP. KITCHEN OUTLET - 42" A.F.F ADA KITCHEN OUTLET - 46" A.F.F ADA BATHROOM VANITY OUTLET - 44" A.F.F ELECTRICAL SWITCH HEIGHTS (U.N.O) SWITCH - 44" A.F.F THERMOSTAT REMOTE - 48" A.F.F MAX TO TOP OF SWITCH SD 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216UNIT INT. ELEVATIONS -KING 1-BEDROOM A-417B FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 FFL FFL 1/2" = 1'-0" Reference: 1 / A-417 1KING 1-BEDROOM ELEVATION A Units x02 1/2" = 1'-0" Reference: 1 / A-417 2KING 1-BEDROOM ELEVATION B Units x02 1/2" = 1'-0" Reference: 1 / A-417 4KING 1-BEDROOM ELEVATION C Units x02 1/2" = 1'-0" Reference: 1 / A-417 5KING 1-BEDROOM ELEVATION D Units x02 FFL 1/2" = 1'-0" Reference: 1 / A-417 6KING 1-BEDROOM ELEVATION E Units x02 1/2" = 1'-0" Reference: 1 / A-417 7KING 1-BEDROOM ELEVATION F Units x02 1/2" = 1'-0" Reference: 1 / A-417 8KING 1-BEDROOM ELEVATION G Units x02 1/2" = 1'-0" Reference: 1 / A-417 9 KING 1-BEDROOM ELEVATION H Units x02 FFL 1/2" = 1'-0" Reference: 1 / A-417 3KING 1-BEDROOM ELEVATION B1 Units x02 0'1' 2'4' SCALE: 1/2" = 1'-0" FURNISHING SCHEDULE GUESTROOM FURNISHINGS GR-103 CHAIR - KITCHEN STOOL GR-105 SOFA - SLEEP BETWEEN ARMS GR-108 SOFA - SECTIONAL SLEEPER GR-201 SCONCE - NIGHTSTAND GR-203 PENDANT LIGHT - PRODUCTIVITY TABLE GR-204 CEILING LIGHT - 1-BEDROOM SUITE GR-205 LAMP - FLOOR LAMP GR-308 NIGHTSTAND - REGULAR GR-312 TABLE - NESTING GR-314 TABLE - PRODUCTIVITY TABLE (STUDIO) GR-316 CONSOLE - LIVING ROOM (1-BEDROOM) GR-317 DRESSER - BEDROOM (1-BEDROOM) GR-318 DRESSER - HIGHBOY GR-321 CLOSET - KING STUDIO SUITE GR-323 CLOSET - KING 1-BEDROOM SUITE GR-326 VANITY - STUDIO AND 1-BEDROOM SUITES GR-400 STATIC DRAPARY PANELS GR-403 ROLLER SHADE - GUESTROOMS (MANUAL,SHEER/BLACK-OUT, 8' W) GR-410 VALENCE FOR 5' WINDOW GR-412 VALENCE FOR 8' WINDOW GR-413 VALENCE FOR 5' WINDOW - ONE DRAPERYPANEL GR-504 ART- SLEEPING/LIVING GR-505 WALL HOOK GR-506 MIRROR - GUESTROOM FULL LENGTH GR-508 MIRROR - GUESTROOM VANITY GR-800 KITCHENETTE - 1-BEDROOM GR-900 GUESTROOM REFRIGERATOR GR-901 GUESTROOM DISHWASHER GR-902 GUESTROOM COOKTOP - 2 BURNER GR-903 GUESTROOM COOKTOP - 4 BURNER GR-904 GARBAGE DISPOSAL 1/3HP GR-905 MICROWAVE- WITH RECIRCULATING HOOD GR-906GR-911 TELEVISION & TELEVISION MOUNT FURNISHING SCHEDULE GR-907 CLOCK/RADIO GR-908 TELEPHONE - GUESTROOM GR-909/910 GUESTROOM STACKED WASHER/DRYER GR-KS BED - KING (GR-301, 303, 600) HILTON SPECIFIED - OWNER FURNISHED OF-702A CHAIR - BALCONY CHAIR OF-705 TABLE - 17" D OUTDOOR SIDE TABLE OWNER SPECIFIED - OWNER FURNISHED OP-706 FIRE EXTINGUISHER CABINET PLUMBING/MECHANICAL FIXTURES PF-01 TOILET - GUESTROOM PF-03 SHOWER BASE - 60" X 36" WITH LINEARDRAIN PF-07 LAVATORY - UNDERMOUNT, 20" X 14" PF-11 SHOWER HEAD - 2 IN 1 PF-13 SHOWER/TUB VALVE & CONTROL PF-15 FAUCET - LAVATORY PF-40 SINK - KITCHENETTE PF-41 FAUCET - KITCHENETTE TOILET ACCESSORIES HD-01 DUAL TOILET PAPER HOLDER HD-04 WALL-MOUNTED ROBE HOOK HD-04.1 TOWEL BAR HD-05.2 SLIDING SHOWER DOOR HD-08 18" GRAB BAR HD-16 BULK AMENITY DISPENSER ATSHOWERS/TUBS HD-18 FOOT LEDGE FOR SHOWER HD-18.1 SOAP SHELF HD-21 BULK AMENITY DISPENSER AT LAVATORIES KEYNOTES - UNIT PLANS 1 ALIGN 2 GENERAL CONTRACTOR TO COORDINATE W/ FURNITUREFABRICATOR WHERE NECESSARY TO PROVIDE PROPERBLOCKING IN WALL FOR ITEM KEYNOTED 3 NO FINISHES UNDER THE SHOWER PAN / TUB 4 NO FINISHES UNDER MILLWORK CABINETRY 5 TV AND MOUNT NOT TO PROJECT MORE THAN 4" FROMWALL 6 MOTORIZED BLINDS. PROVIDE JUNCTION BOX BEHINDVALENCE FOR POWER CONNECTION AND PERMANENTLYINSTALLED SWITCH ON WALL TO CONTROL BLINDS. 7 SWITCH CONTROLLING UNDER CABINET LIGHTING ATKITCHEN TO BE GANGED WITH LIGHTING AT ENTRY 8 SWITCH CONTROLLING GARBAGE DISPOSAL-REFER TOHADG FOR ACCESSIBLE ROOM REQ'S. 9 DEDICATED CIRCUIT FOR GARBAGE DISPOSAL 10 MASTER SWITCH 11 DEDICATED CIRCUIT FOR INDUCTION COOKTOP 12 DEDICATED CIRCUIT FOR DISHWASHER 13 DEDICATED CIRCUIT FOR REFRIGERATOR 14 ELECTRIC VANITY MIRROR - HARDWIRE FIXTURE TO WALL-CONTRACTOR TO VERIFY JBOX TYPE TO ENSURE PROPERINSTALLATION AND BACKING FOR ITEM KEYNOTED 15 DOORBELL AND DOORBELL ON/OFF SWITCH(COMMUNICATION FEATURES ROOMS ONLY)SIGNAGE ASREQ'D. 16 PLACE TV OUTLETS AND CONNECTIONS ON WALL OUTSIDEAREA OF BRACKET AND CONCEALED FROM VIEW BY TV 17 DEDICATED CIRCUIT FOR WASHER/DRYER. DIRECT VENTTO EXTERIOR 1/2" = 1'-0" POWER AND SIGNAL LEGEND Copy 1 Copy 1 EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV Revision Schedule Number Description Date WDM A A M WDTVTVSD SD SD SD TV 12' - 9"A-418B 3 1 42 A-418B9 6 7 8 D-G05A P2.1 P1.2 P1.1 P3.1 D-G01A D-G04A GR-316GR-906GR-911 GR-312 GR-101 GR-105 GR-205 3' - 0 1/4" GR-324 GR-308 GR-201 GR-201 GR-308 W-K 13' - 3" 4' - 9"2' - 1 1/2"GR-314 GR-103GR-103 GR-103GR-103 GR-KM GR-504 GR-317 GR-906GR-911 GR-900 GR-901 GR-903 GR-907 GR-908 GR-400 GR-400 A-418B5 D-G02A A-4242 OF-702A OF-705 OF-702A GR-910 GR-909 GR-913 PF-40 PF-41 GR-803 GR-400 14' - 3" GR-410GR-400 GR-400 CL-B8' - 0" CL-B8' - 0" 1 1 1 1 1 1 1 1' - 5" EQ EQ EQ EQ 2' - 11"EQ1' - 3"1' - 3" EQ 4' - 0"4' - 0"6' - 5 1/4"3' - 3 1/2"3' - 1"1' - 0"1' - 4"1' - 0"1' - 0"A-4243 Sim GR-203 GR-203 GR-204 GR-413 GR-405 GR-405 GR-410 GR-400 GR-400 GR-913 PLANELEV DUPLEX OUTLET QUADPLEX OUTLET GFCI OUTLET CAT6, RJ45 INTERNET OUTLET TELEPHONE OUTLET WALL MOUNTED WIRELESS THERMOSTAT POWER OUTLET WITH USB PORTS CATV OUTLET ELECTRICAL SWITCH FLOOR OUTLET POWER AND SIGNAL LEGEND: POWER SUPPLY JUNCTION BOX DOOR BELL HARDWIRED TO DOORBELL LIGHT - MOUNT @ 46" A.F.F TO CENTER OF BUTTON (FOR COMMUNICATIONS FEATURES ROOMS ONLY) CEILING FIXTURE LEGEND: 6" RECESSED CAN DOWNLIGHT DECORATIVE FLUSH MOUNT LIGHT PENDENT TYPE SPRINKLERS SMOKE DETECTOR EXHAUST FAN / GRILLE LINEAR SURFACE MOUNTED CONTINUOUS LED SYSTEM W/ FIXED MOUNTING CLIPS & FROSTED LENS / 3 WATTS PER FOOT, MLV/FWD ELECTRICAL OUTLET HEIGHTS (U.N.O) TYPICAL OUTLET - 15" A.F.F TYPICAL ACCESSIBLE WALL OUTLET - 18" A.F.F BATHROOM VANITY OUTLET - 42" A.F.F TYP. KITCHEN OUTLET - 42" A.F.F ADA KITCHEN OUTLET - 46" A.F.F ADA BATHROOM VANITY OUTLET - 44" A.F.F ELECTRICAL SWITCH HEIGHTS (U.N.O) SWITCH - 44" A.F.F THERMOSTAT REMOTE - 48" A.F.F MAX TO TOP OF SWITCH SD 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216UNIT PLAN - KING1-BEDROOM ADAMOBILITY A-418 FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 1/2" = 1'-0" Reference: 1 / A-103 1KING 1-BEDROOM ADA MOBILITY CONSTRUCTION PLAN Unit 301 1/2" = 1'-0"2 KING 1-BEDROOM ADA MOBILITY REFLECTED CEILING PLAN Unit 301 0'1' 2'4' SCALE: 1/2" = 1'-0" 25 2 2 2 2 2 5 FURNISHING SCHEDULE GUESTROOM FURNISHINGS GR-101 CHAIR - LOUNGE CHAIR IN STUIDOS GR-103 CHAIR - KITCHEN STOOL GR-105 SOFA - SLEEP BETWEEN ARMS GR-200 SCONCE - PIN-UP GR-201 SCONCE - NIGHTSTAND GR-203 PENDANT LIGHT - PRODUCTIVITY TABLE GR-204 CEILING LIGHT - 1-BEDROOM SUITE GR-205 LAMP - FLOOR LAMP GR-308 NIGHTSTAND - REGULAR GR-312 TABLE - NESTING GR-314 TABLE - PRODUCTIVITY TABLE (STUDIO) GR-316 CONSOLE - LIVING ROOM (1-BEDROOM) GR-317 DRESSER - BEDROOM (1-BEDROOM) GR-324 CLOSET - ACCESSIBLE KING 1-BEDROOMSUITE GR-327 VANITY - ACCESSIBLE SUITES GR-328 BATH CADDY - ACCESSIBLE SUITES GR-400 STATIC DRAPARY PANELS GR-405 ROLLER SHADE - GUESTROOMS (MANUAL,SHEER/BLACK-OUT, 8' W) FURNISHING SCHEDULE GR-410 VALENCE FOR 5' WINDOW GR-413 VALENCE FOR 5' WINDOW - ONE DRAPERYPANEL GR-503 ART- ENTRY GR-504 ART- SLEEPING/LIVING GR-505 WALL HOOK GR-507 MIRROR - ADA VANITY GR-800 KITCHENETTE - 1-BEDROOM GR-802 KITCHENETTE - EFFICIENCY SUITE GR-803 KITCHENETTE - ONE BEDROOM SUITE GR-900 GUESTROOM REFRIGERATOR GR-901 GUESTROOM DISHWASHER GR-903 GUESTROOM COOKTOP - 4 BURNER GR-904 GARBAGE DISPOSAL 1/3HP GR-906GR-911 TELEVISION & TELEVISION MOUNT GR-907 CLOCK/RADIO GR-908 TELEPHONE - GUESTROOM GR-909 GUESTROOM WASHING MACHINE GR-910 GUESTROOM DRYER GR-913 COUNTERTOP MICROWAVE FURNISHING SCHEDULE GR-KM BED - KING MOBILITY (GR-301, 304, 600, 602) HILTON SPECIFIED - OWNER FURNISHED OF-702A CHAIR - BALCONY CHAIR OF-705 TABLE - 17" D OUTDOOR SIDE TABLE PLUMBING/MECHANICAL FIXTURES PF-01 TOILET - GUESTROOM PF-03 SHOWER BASE - 60" X 36" WITH LINEARDRAIN PF-06 BATHTUB - 5' X 32" WITH SIDE LEDGE PF-07 LAVATORY - UNDERMOUNT, 20" X 14" PF-10 SHOWER HEAD - HIGH PF-12 SHOWER HEAD - HAND HELD ON SLIDE BAR PF-13 SHOWER/TUB VALVE & CONTROL PF-14 BATHTUB FILL FAUCET PF-15 FAUCET - LAVATORY PF-40 SINK - KITCHENETTE PF-41 FAUCET - KITCHENETTE KEYNOTES - UNIT PLANS 1 ALIGN 2 GENERAL CONTRACTOR TO COORDINATE W/ FURNITUREFABRICATOR WHERE NECESSARY TO PROVIDE PROPERBLOCKING IN WALL FOR ITEM KEYNOTED 3 NO FINISHES UNDER THE SHOWER PAN / TUB 4 NO FINISHES UNDER MILLWORK CABINETRY 5 TV AND MOUNT NOT TO PROJECT MORE THAN 4" FROMWALL 6 MOTORIZED BLINDS. PROVIDE JUNCTION BOX BEHINDVALENCE FOR POWER CONNECTION AND PERMANENTLYINSTALLED SWITCH ON WALL TO CONTROL BLINDS. 7 SWITCH CONTROLLING UNDER CABINET LIGHTING ATKITCHEN TO BE GANGED WITH LIGHTING AT ENTRY 8 SWITCH CONTROLLING GARBAGE DISPOSAL-REFER TOHADG FOR ACCESSIBLE ROOM REQ'S. 9 DEDICATED CIRCUIT FOR GARBAGE DISPOSAL 10 MASTER SWITCH 11 DEDICATED CIRCUIT FOR INDUCTION COOKTOP 12 DEDICATED CIRCUIT FOR DISHWASHER 13 DEDICATED CIRCUIT FOR REFRIGERATOR 14 ELECTRIC VANITY MIRROR - HARDWIRE FIXTURE TO WALL-CONTRACTOR TO VERIFY JBOX TYPE TO ENSURE PROPERINSTALLATION AND BACKING FOR ITEM KEYNOTED 15 DOORBELL AND DOORBELL ON/OFF SWITCH(COMMUNICATION FEATURES ROOMS ONLY)SIGNAGE ASREQ'D. 16 PLACE TV OUTLETS AND CONNECTIONS ON WALL OUTSIDEAREA OF BRACKET AND CONCEALED FROM VIEW BY TV 17 DEDICATED CIRCUIT FOR WASHER/DRYER. DIRECT VENTTO EXTERIOR FURNISHING SCHEDULE TOILET ACCESSORIES HD-02 DUAL TOILET PAPER HOLDER- ADA HD-04 WALL-MOUNTED ROBE HOOK HD-04.1 TOWEL BAR HD-05 CURVED CURTAIN ROD AND SHOWERCURTAIN HD-08 18" GRAB BAR HD-09 24" GRAB BAR HD-10 42" GRAB BAR AT ADA BATHTUB HD-11 36" GRAB BAR HD-11.1 42" GRAB BAR HD-14.1 ROLL-IN SHOWER SEAT HD-16 BULK AMENITY DISPENSER ATSHOWERS/TUBS HD-18.1 SOAP SHELF HD-20 12" GRAB BAR HD-21 BULK AMENITY DISPENSER AT LAVATORIES EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV Revision Schedule Number Description Date WDTVTVTV A-418B 3 1 42 A-418B9 6 7 8 GFCI A-418B5FULL TILEFULL TILE EQFULL TILE SF-01 SF-01SF-01 WC-01 WC-01 WC-01 WC-01 WC-01 WC-01 WC-01 WC-01 RES-01 CPT-01 RES-01 8 A-510 Sim 9 A-510 Sim 7 A-510 Sim 7 A-510 Sim PLANELEV DUPLEX OUTLET QUADPLEX OUTLET GFCI OUTLET CAT6, RJ45 INTERNET OUTLET TELEPHONE OUTLET WALL MOUNTED WIRELESS THERMOSTAT POWER OUTLET WITH USB PORTS CATV OUTLET ELECTRICAL SWITCH FLOOR OUTLET POWER AND SIGNAL LEGEND: POWER SUPPLY JUNCTION BOX DOOR BELL HARDWIRED TO DOORBELL LIGHT - MOUNT @ 46" A.F.F TO CENTER OF BUTTON (FOR COMMUNICATIONS FEATURES ROOMS ONLY) CEILING FIXTURE LEGEND: 6" RECESSED CAN DOWNLIGHT DECORATIVE FLUSH MOUNT LIGHT PENDENT TYPE SPRINKLERS SMOKE DETECTOR EXHAUST FAN / GRILLE LINEAR SURFACE MOUNTED CONTINUOUS LED SYSTEM W/ FIXED MOUNTING CLIPS & FROSTED LENS / 3 WATTS PER FOOT, MLV/FWD ELECTRICAL OUTLET HEIGHTS (U.N.O) TYPICAL OUTLET - 15" A.F.F TYPICAL ACCESSIBLE WALL OUTLET - 18" A.F.F BATHROOM VANITY OUTLET - 42" A.F.F TYP. KITCHEN OUTLET - 42" A.F.F ADA KITCHEN OUTLET - 46" A.F.F ADA BATHROOM VANITY OUTLET - 44" A.F.F ELECTRICAL SWITCH HEIGHTS (U.N.O) SWITCH - 44" A.F.F THERMOSTAT REMOTE - 48" A.F.F MAX TO TOP OF SWITCH SD 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216UNIT PLAN - KING1-BEDROOM ADA -ELEC, DATA & FLOORFINISH PLAN A-418A FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 0'1' 2'4' SCALE: 1/2" = 1'-0" 1/2" = 1'-0"1KING 1-BEDROOM ADA MOBILITY ELECTRICAL & DATA PLAN Unit 301 1/2" = 1'-0"2 KING 1-BEDROOM ADA MOBILITY FLOOR & WALL FINISH PLAN Unit 301 16 16 15 710 12 8 9 11 13 17 3 14 FURNISHING SCHEDULE GUESTROOM FURNISHINGS GR-101 CHAIR - LOUNGE CHAIR IN STUIDOS GR-103 CHAIR - KITCHEN STOOL GR-105 SOFA - SLEEP BETWEEN ARMS GR-201 SCONCE - NIGHTSTAND GR-205 LAMP - FLOOR LAMP GR-308 NIGHTSTAND - REGULAR GR-312 TABLE - NESTING GR-314 TABLE - PRODUCTIVITY TABLE (STUDIO) GR-316 CONSOLE - LIVING ROOM (1-BEDROOM) GR-317 DRESSER - BEDROOM (1-BEDROOM) GR-324 CLOSET - ACCESSIBLE KING 1-BEDROOMSUITE GR-327 VANITY - ACCESSIBLE SUITES GR-328 BATH CADDY - ACCESSIBLE SUITES GR-400 STATIC DRAPARY PANELS GR-504 ART- SLEEPING/LIVING GR-507 MIRROR - ADA VANITY GR-800 KITCHENETTE - 1-BEDROOM GR-803 KITCHENETTE - ONE BEDROOM SUITE GR-900 GUESTROOM REFRIGERATOR FURNISHING SCHEDULE GR-901 GUESTROOM DISHWASHER GR-903 GUESTROOM COOKTOP - 4 BURNER GR-904 GARBAGE DISPOSAL 1/3HP GR-906GR-911 TELEVISION & TELEVISION MOUNT GR-907 CLOCK/RADIO GR-908 TELEPHONE - GUESTROOM GR-909 GUESTROOM WASHING MACHINE GR-910 GUESTROOM DRYER GR-913 COUNTERTOP MICROWAVE GR-KM BED - KING MOBILITY (GR-301, 304, 600, 602) PLUMBING/MECHANICAL FIXTURES PF-01 TOILET - GUESTROOM PF-06 BATHTUB - 5' X 32" WITH SIDE LEDGE PF-07 LAVATORY - UNDERMOUNT, 20" X 14" PF-12 SHOWER HEAD - HAND HELD ON SLIDE BAR PF-13 SHOWER/TUB VALVE & CONTROL PF-14 BATHTUB FILL FAUCET PF-15 FAUCET - LAVATORY PF-40 SINK - KITCHENETTE FURNISHING SCHEDULE PF-41 FAUCET - KITCHENETTE TOILET ACCESSORIES HD-02 DUAL TOILET PAPER HOLDER- ADA HD-04 WALL-MOUNTED ROBE HOOK HD-04.1 TOWEL BAR HD-08 18" GRAB BAR HD-09 24" GRAB BAR HD-10 42" GRAB BAR AT ADA BATHTUB HD-11 36" GRAB BAR HD-11.1 42" GRAB BAR HD-14.1 ROLL-IN SHOWER SEAT HD-16 BULK AMENITY DISPENSER ATSHOWERS/TUBS HD-18.1 SOAP SHELF HD-20 12" GRAB BAR HD-21 BULK AMENITY DISPENSER AT LAVATORIES KEYNOTES - UNIT PLANS 1 ALIGN 2 GENERAL CONTRACTOR TO COORDINATE W/ FURNITUREFABRICATOR WHERE NECESSARY TO PROVIDE PROPERBLOCKING IN WALL FOR ITEM KEYNOTED 3 NO FINISHES UNDER THE SHOWER PAN / TUB 4 NO FINISHES UNDER MILLWORK CABINETRY 5 TV AND MOUNT NOT TO PROJECT MORE THAN 4" FROMWALL 6 MOTORIZED BLINDS. PROVIDE JUNCTION BOX BEHINDVALENCE FOR POWER CONNECTION AND PERMANENTLYINSTALLED SWITCH ON WALL TO CONTROL BLINDS. 7 SWITCH CONTROLLING UNDER CABINET LIGHTING ATKITCHEN TO BE GANGED WITH LIGHTING AT ENTRY 8 SWITCH CONTROLLING GARBAGE DISPOSAL-REFER TOHADG FOR ACCESSIBLE ROOM REQ'S. 9 DEDICATED CIRCUIT FOR GARBAGE DISPOSAL 10 MASTER SWITCH 11 DEDICATED CIRCUIT FOR INDUCTION COOKTOP 12 DEDICATED CIRCUIT FOR DISHWASHER 13 DEDICATED CIRCUIT FOR REFRIGERATOR 14 ELECTRIC VANITY MIRROR - HARDWIRE FIXTURE TO WALL-CONTRACTOR TO VERIFY JBOX TYPE TO ENSURE PROPERINSTALLATION AND BACKING FOR ITEM KEYNOTED 15 DOORBELL AND DOORBELL ON/OFF SWITCH(COMMUNICATION FEATURES ROOMS ONLY)SIGNAGE ASREQ'D. 16 PLACE TV OUTLETS AND CONNECTIONS ON WALL OUTSIDEAREA OF BRACKET AND CONCEALED FROM VIEW BY TV 17 DEDICATED CIRCUIT FOR WASHER/DRYER. DIRECT VENTTO EXTERIOR EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV Revision Schedule Number Description Date TV WC-01SF-01 RB-01 D-G04A W-K D-G05A PT-03 GR-405 PL-02 GR-324 GR-103 GR-413GR-405 GR-203GR-203 SF-01 RB-01 W-H WD-01 WD-01 GR-410 GR-405 GR-400 GR-400 GR-316 PT-03PL-02 0' - 9" WC-01 GR-505 D-G03AD-G02A PT-03PL-02 WC-01 RB-01 PT-11 PL-01 WC-01 RB-01 D-G01A 6 SF-01W-K RB-01 GR-410 16 A-510 Sim GR-405 GR-400 WC-01 RB-01 GR-405 4' - 5 1/2"5' - 0"PT-03 PL-02RB-01 WC-01 D-G05A RB-01 WC-01 6' - 2 1/2" GR-405 WC-01 RB-10 PL-01PT-11 D-G01A PLANELEV DUPLEX OUTLET QUADPLEX OUTLET GFCI OUTLET CAT6, RJ45 INTERNET OUTLET TELEPHONE OUTLET WALL MOUNTED WIRELESS THERMOSTAT POWER OUTLET WITH USB PORTS CATV OUTLET ELECTRICAL SWITCH FLOOR OUTLET POWER AND SIGNAL LEGEND: POWER SUPPLY JUNCTION BOX DOOR BELL HARDWIRED TO DOORBELL LIGHT - MOUNT @ 46" A.F.F TO CENTER OF BUTTON (FOR COMMUNICATIONS FEATURES ROOMS ONLY) CEILING FIXTURE LEGEND: 6" RECESSED CAN DOWNLIGHT DECORATIVE FLUSH MOUNT LIGHT PENDENT TYPE SPRINKLERS SMOKE DETECTOR EXHAUST FAN / GRILLE LINEAR SURFACE MOUNTED CONTINUOUS LED SYSTEM W/ FIXED MOUNTING CLIPS & FROSTED LENS / 3 WATTS PER FOOT, MLV/FWD ELECTRICAL OUTLET HEIGHTS (U.N.O) TYPICAL OUTLET - 15" A.F.F TYPICAL ACCESSIBLE WALL OUTLET - 18" A.F.F BATHROOM VANITY OUTLET - 42" A.F.F TYP. KITCHEN OUTLET - 42" A.F.F ADA KITCHEN OUTLET - 46" A.F.F ADA BATHROOM VANITY OUTLET - 44" A.F.F ELECTRICAL SWITCH HEIGHTS (U.N.O) SWITCH - 44" A.F.F THERMOSTAT REMOTE - 48" A.F.F MAX TO TOP OF SWITCH SD 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216UNIT INT. ELEVATIONS -KING 1-BR ADAMOBILITY A-418B FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 FFL FFL FFL 1/2" = 1'-0" Reference: 1 / A-418 1KING ADA 1-BEDROOM ELEVATION A Room 301 1/2" = 1'-0" Reference: 1 / A-413 2 KING ADA 1-BEDROOM ELEVATION B Room 301 1/2" = 1'-0" Reference: 1 / A-418 3KING ADA 1-BEDROOM ELEVATION C Room 301 1/2" = 1'-0" Reference: 1 / A-413 4 KING ADA 1-BEDROOM ELEVATION D Room 301 1/2" = 1'-0" Reference: 1 / A-418 6KING ADA 1-BEDROOM ELEVATION A2 Room 301 1/2" = 1'-0" Reference: 1 / A-418 7KING ADA 1-BEDROOM ELEVATION B2 Room 301 1/2" = 1'-0" Reference: 1 / A-418 8 KING ADA 1-BEDROOM ELEVATION C2 Room 301 1/2" = 1'-0" Reference: 1 / A-418 9KING ADA 1-BEDROOM ELEVATION D2 Room 301 FFL 1/2" = 1'-0" Reference: 1 / A-418 5KING ADA 1-BEDROOM ELEVATION D3 Room 301 FURNISHING SCHEDULE GUESTROOM FURNISHINGS GR-100 CHAIR - LOUNGE CHAIR WITH OTTOMAN GR-101 CHAIR - LOUNGE CHAIR IN STUIDOS GR-102 CHAIR - COUNTER HEIGHT DESK CHAIR GR-103 CHAIR - KITCHEN STOOL FURNISHING SCHEDULE GR-105 SOFA - SLEEP BETWEEN ARMS GR-200 SCONCE - PIN-UP GR-201 SCONCE - NIGHTSTAND GR-203 PENDANT LIGHT - PRODUCTIVITY TABLE GR-204 CEILING LIGHT - 1-BEDROOM SUITE GR-205 LAMP - FLOOR LAMP GR-308 NIGHTSTAND - REGULAR GR-310 DESK - EFFICIENCY GR-312 TABLE - NESTING GR-313 TABLE - ROUND SIDE TABLE GR-314 TABLE - PRODUCTIVITY TABLE (STUDIO) GR-316 CONSOLE - LIVING ROOM (1-BEDROOM) FURNISHING SCHEDULE GR-317 DRESSER - BEDROOM (1-BEDROOM) GR-319 CLOSET - EFFICIENCY SUITE GR-324 CLOSET - ACCESSIBLE KING 1-BEDROOM SUITE GR-327 VANITY - ACCESSIBLE SUITES GR-328 BATH CADDY - ACCESSIBLE SUITES GR-400 STATIC DRAPARY PANELS GR-403 ROLLER SHADE - GUESTROOMS (MANUAL,SHEER/BLACK-OUT, 8' W) GR-405 ROLLER SHADE - GUESTROOMS (MANUAL,SHEER/BLACK-OUT, 8' W) GR-410 VALENCE FOR 5' WINDOW GR-413 VALENCE FOR 5' WINDOW - ONE DRAPERYPANEL KEYNOTES - UNIT PLANS 1 ALIGN 2 GENERAL CONTRACTOR TO COORDINATE W/ FURNITUREFABRICATOR WHERE NECESSARY TO PROVIDE PROPERBLOCKING IN WALL FOR ITEM KEYNOTED 3 NO FINISHES UNDER THE SHOWER PAN / TUB 4 NO FINISHES UNDER MILLWORK CABINETRY 5 TV AND MOUNT NOT TO PROJECT MORE THAN 4" FROMWALL 6 MOTORIZED BLINDS. PROVIDE JUNCTION BOX BEHINDVALENCE FOR POWER CONNECTION AND PERMANENTLYINSTALLED SWITCH ON WALL TO CONTROL BLINDS. 7 SWITCH CONTROLLING UNDER CABINET LIGHTING ATKITCHEN TO BE GANGED WITH LIGHTING AT ENTRY 8 SWITCH CONTROLLING GARBAGE DISPOSAL-REFER TOHADG FOR ACCESSIBLE ROOM REQ'S. 9 DEDICATED CIRCUIT FOR GARBAGE DISPOSAL 10 MASTER SWITCH 11 DEDICATED CIRCUIT FOR INDUCTION COOKTOP 12 DEDICATED CIRCUIT FOR DISHWASHER 13 DEDICATED CIRCUIT FOR REFRIGERATOR 14 ELECTRIC VANITY MIRROR - HARDWIRE FIXTURE TO WALL-CONTRACTOR TO VERIFY JBOX TYPE TO ENSURE PROPERINSTALLATION AND BACKING FOR ITEM KEYNOTED 15 DOORBELL AND DOORBELL ON/OFF SWITCH(COMMUNICATION FEATURES ROOMS ONLY)SIGNAGE ASREQ'D. 16 PLACE TV OUTLETS AND CONNECTIONS ON WALL OUTSIDEAREA OF BRACKET AND CONCEALED FROM VIEW BY TV 17 DEDICATED CIRCUIT FOR WASHER/DRYER. DIRECT VENTTO EXTERIOR FURNISHING SCHEDULE GR-503 ART- ENTRY GR-504 ART- SLEEPING/LIVING GR-505 WALL HOOK GR-507 MIRROR - ADA VANITY GR-508 MIRROR - GUESTROOM VANITY GR-800 KITCHENETTE - 1-BEDROOM GR-802 KITCHENETTE - EFFICIENCY SUITE GR-803 KITCHENETTE - ONE BEDROOM SUITE GR-900 GUESTROOM REFRIGERATOR GR-901 GUESTROOM DISHWASHER GR-902 GUESTROOM COOKTOP - 2 BURNER GR-903 GUESTROOM COOKTOP - 4 BURNER GR-904 GARBAGE DISPOSAL 1/3HP GR-905 MICROWAVE- WITH RECIRCULATING HOOD GR-906GR-911 TELEVISION & TELEVISION MOUNT GR-907 CLOCK/RADIO GR-908 TELEPHONE - GUESTROOM GR-909 GUESTROOM WASHING MACHINE GR-910 GUESTROOM DRYER GR-913 COUNTERTOP MICROWAVE GR-ES BED - EFFICIENCY (GR-300, 303, 600) GR-KM BED - KING MOBILITY (GR-301, 304, 600, 602) HILTON SPECIFIED - OWNER FURNISHED OF-702A CHAIR - BALCONY CHAIR OF-705 TABLE - 17" D OUTDOOR SIDE TABLE OWNER SPECIFIED - OWNER FURNISHED OP-706 FIRE EXTINGUISHER CABINET FURNISHING SCHEDULE PLUMBING/MECHANICAL FIXTURES PF-01 TOILET - GUESTROOM PF-03 SHOWER BASE - 60" X 36" WITH LINEAR DRAIN PF-06 BATHTUB - 5' X 32" WITH SIDE LEDGE PF-07 LAVATORY - UNDERMOUNT, 20" X 14" PF-10 SHOWER HEAD - HIGH PF-12 SHOWER HEAD - HAND HELD ON SLIDE BAR PF-13 SHOWER/TUB VALVE & CONTROL PF-14 BATHTUB FILL FAUCET PF-15 FAUCET - LAVATORY PF-40 SINK - KITCHENETTE PF-41 FAUCET - KITCHENETTE TOILET ACCESSORIES HD-02 DUAL TOILET PAPER HOLDER- ADA HD-04 WALL-MOUNTED ROBE HOOK HD-04.1 TOWEL BAR HD-05 CURVED CURTAIN ROD AND SHOWER CURTAIN HD-05.2 SLIDING SHOWER DOOR HD-08 18" GRAB BAR HD-09 24" GRAB BAR HD-10 42" GRAB BAR AT ADA BATHTUB HD-11 36" GRAB BAR HD-11.1 42" GRAB BAR HD-14.1 ROLL-IN SHOWER SEAT HD-16 BULK AMENITY DISPENSER AT SHOWERS/TUBS HD-18 FOOT LEDGE FOR SHOWER HD-18.1 SOAP SHELF HD-20 12" GRAB BAR HD-21 BULK AMENITY DISPENSER AT LAVATORIES EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV Revision Schedule Number Description Date W/DW/DM A A M SD SD SD SD TV TV 58 SF BALCONY 201A A-419B2 1 4 3 A-419B 6 7 8 9 P3.1 P2.1 D-G05 P1.1 P1.2 D-G03 D-G03 D-G04 D-G01 7' - 0" 12' - 10 1/4"14' - 7 3/4"7' - 5 1/4"6' - 6 1/2"15' - 9 1/4" 2' - 11" D-G02A2' - 0 1/2"2' - 10 3/4"2' - 1 1/4"GR-312 GR-108 GR-205 GR-316 11' - 9" 4' - 9" GR-906GR-911 GR-323 GR-326 GR-900 GR-903 GR-901 GR-103 GR-103GR-103 GR-103 GR-ES GR-317 GR-906GR-911 GR-308 GR-308 GR-201 GR-201 GR-508 GR-504 GR-503 GR-908 GR-90712' - 7"GR-400GR-400 A-419B5 GR-506 GR-315 GR-909/910 GR-800 0' - 3"GR-400 GR-400 PF-40 PF-41 OF-702A OF-702A OF-705 A-425 1 GR-410GR-400 GR-400 CL-B8' - 0" CL-B8' - 0" CL-B8' - 0" 1' - 0"1' - 0" 1 1 1 1 1 1 1 EQ EQ 3' - 2 3/4"3' - 3 1/4"4' - 0"4' - 0" EQ1' - 0"1' - 4"1' - 3"1' - 3"3' - 1"EQEQ2' - 2"EQ 1' - 5"2' - 1" EQ1' - 5"A-425 3 Sim PLANELEV DUPLEX OUTLET QUADPLEX OUTLET GFCI OUTLET CAT6, RJ45 INTERNET OUTLET TELEPHONE OUTLET WALL MOUNTED WIRELESS THERMOSTAT POWER OUTLET WITH USB PORTS CATV OUTLET ELECTRICAL SWITCH FLOOR OUTLET POWER AND SIGNAL LEGEND: POWER SUPPLY JUNCTION BOX DOOR BELL HARDWIRED TO DOORBELL LIGHT - MOUNT @ 46" A.F.F TO CENTER OF BUTTON (FOR COMMUNICATIONS FEATURES ROOMS ONLY) CEILING FIXTURE LEGEND: 6" RECESSED CAN DOWNLIGHT DECORATIVE FLUSH MOUNT LIGHT PENDENT TYPE SPRINKLERS SMOKE DETECTOR EXHAUST FAN / GRILLE LINEAR SURFACE MOUNTED CONTINUOUS LED SYSTEM W/ FIXED MOUNTING CLIPS & FROSTED LENS / 3 WATTS PER FOOT, MLV/FWD ELECTRICAL OUTLET HEIGHTS (U.N.O) TYPICAL OUTLET - 15" A.F.F TYPICAL ACCESSIBLE WALL OUTLET - 18" A.F.F BATHROOM VANITY OUTLET - 42" A.F.F TYP. KITCHEN OUTLET - 42" A.F.F ADA KITCHEN OUTLET - 46" A.F.F ADA BATHROOM VANITY OUTLET - 44" A.F.F ELECTRICAL SWITCH HEIGHTS (U.N.O) SWITCH - 44" A.F.F THERMOSTAT REMOTE - 48" A.F.F MAX TO TOP OF SWITCH SD 1/2" = 1'-0"2 KING 1-BEDROOM ENLARGED REFLECTED CEILING PLAN Units 201, 401, 501 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216UNIT PLAN - KING1-BEDROOM ENLARGED A-419 FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 1/2" = 1'-0" Reference: 1 / A-102 1KING 1-BEDROOM ENLARGED CONSTRUCTION PLAN Units 201, 401, 501 0'1' 2'4' SCALE: 1/2" = 1'-0" 2 5 2 2 5 2 2 2 FURNISHING SCHEDULE GUESTROOM FURNISHINGS GR-100 CHAIR - LOUNGE CHAIR WITH OTTOMAN GR-103 CHAIR - KITCHEN STOOL GR-108 SOFA - SECTIONAL SLEEPER GR-200 SCONCE - PIN-UP GR-201 SCONCE - NIGHTSTAND GR-203 PENDANT LIGHT - PRODUCTIVITY TABLE GR-204 CEILING LIGHT - 1-BEDROOM SUITE GR-205 LAMP - FLOOR LAMP GR-308 NIGHTSTAND - REGULAR GR-312 TABLE - NESTING GR-315 TABLE - PRODUCTIVITY TABLE(1-BEDROOM) GR-316 CONSOLE - LIVING ROOM (1-BEDROOM) GR-317 DRESSER - BEDROOM (1-BEDROOM) GR-323 CLOSET - KING 1-BEDROOM SUITE GR-326 VANITY - STUDIO AND 1-BEDROOM SUITES GR-400 STATIC DRAPARY PANELS GR-403 ROLLER SHADE - GUESTROOMS (MANUAL,SHEER/BLACK-OUT, 8' W) GR-410 VALENCE FOR 5' WINDOW FURNISHING SCHEDULE GR-411 VALENCE FOR 5' WINDOW - ONE DRAPERYPANEL GR-503 ART- ENTRY GR-504 ART- SLEEPING/LIVING GR-505 WALL HOOK GR-506 MIRROR - GUESTROOM FULL LENGTH GR-508 MIRROR - GUESTROOM VANITY GR-800 KITCHENETTE - 1-BEDROOM GR-802 KITCHENETTE - EFFICIENCY SUITE GR-900 GUESTROOM REFRIGERATOR GR-901 GUESTROOM DISHWASHER GR-902 GUESTROOM COOKTOP - 2 BURNER GR-903 GUESTROOM COOKTOP - 4 BURNER GR-904 GARBAGE DISPOSAL 1/3HP GR-905 MICROWAVE- WITH RECIRCULATING HOOD GR-906GR-911 TELEVISION & TELEVISION MOUNT GR-907 CLOCK/RADIO GR-908 TELEPHONE - GUESTROOM GR-909/910 GUESTROOM STACKED WASHER/DRYER FURNISHING SCHEDULE GR-ES BED - EFFICIENCY (GR-300, 303, 600) HILTON SPECIFIED - OWNER FURNISHED OF-702A CHAIR - BALCONY CHAIR OF-705 TABLE - 17" D OUTDOOR SIDE TABLE PLUMBING/MECHANICAL FIXTURES PF-01 TOILET - GUESTROOM PF-03 SHOWER BASE - 60" X 36" WITH LINEARDRAIN PF-06 BATHTUB - 5' X 32" WITH SIDE LEDGE PF-07 LAVATORY - UNDERMOUNT, 20" X 14" PF-11 SHOWER HEAD - 2 IN 1 PF-13 SHOWER/TUB VALVE & CONTROL PF-15 FAUCET - LAVATORY PF-40 SINK - KITCHENETTE PF-41 FAUCET - KITCHENETTE TOILET ACCESSORIES KEYNOTES - UNIT PLANS 1 ALIGN 2 GENERAL CONTRACTOR TO COORDINATE W/ FURNITUREFABRICATOR WHERE NECESSARY TO PROVIDE PROPERBLOCKING IN WALL FOR ITEM KEYNOTED 3 NO FINISHES UNDER THE SHOWER PAN / TUB 4 NO FINISHES UNDER MILLWORK CABINETRY 5 TV AND MOUNT NOT TO PROJECT MORE THAN 4" FROMWALL 6 MOTORIZED BLINDS. PROVIDE JUNCTION BOX BEHINDVALENCE FOR POWER CONNECTION AND PERMANENTLYINSTALLED SWITCH ON WALL TO CONTROL BLINDS. 7 SWITCH CONTROLLING UNDER CABINET LIGHTING ATKITCHEN TO BE GANGED WITH LIGHTING AT ENTRY 8 SWITCH CONTROLLING GARBAGE DISPOSAL-REFER TOHADG FOR ACCESSIBLE ROOM REQ'S. 9 DEDICATED CIRCUIT FOR GARBAGE DISPOSAL 10 MASTER SWITCH 11 DEDICATED CIRCUIT FOR INDUCTION COOKTOP 12 DEDICATED CIRCUIT FOR DISHWASHER 13 DEDICATED CIRCUIT FOR REFRIGERATOR 14 ELECTRIC VANITY MIRROR - HARDWIRE FIXTURE TO WALL-CONTRACTOR TO VERIFY JBOX TYPE TO ENSURE PROPERINSTALLATION AND BACKING FOR ITEM KEYNOTED 15 DOORBELL AND DOORBELL ON/OFF SWITCH(COMMUNICATION FEATURES ROOMS ONLY)SIGNAGE ASREQ'D. 16 PLACE TV OUTLETS AND CONNECTIONS ON WALL OUTSIDEAREA OF BRACKET AND CONCEALED FROM VIEW BY TV 17 DEDICATED CIRCUIT FOR WASHER/DRYER. DIRECT VENTTO EXTERIOR FURNISHING SCHEDULE HD-01 DUAL TOILET PAPER HOLDER HD-04 WALL-MOUNTED ROBE HOOK HD-04.1 TOWEL BAR HD-05.2 SLIDING SHOWER DOOR HD-08 18" GRAB BAR HD-16 BULK AMENITY DISPENSER ATSHOWERS/TUBS HD-18 FOOT LEDGE FOR SHOWER HD-18.1 SOAP SHELF HD-21 BULK AMENITY DISPENSER AT LAVATORIES EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV Revision Schedule Number Description Date W/DTV TV A-419B2 1 4 3 A-419B 6 7 8 9 A-419B5 WC-01 WC-01 WC-01 WC-01 WC-01 WC-01 WC-01 WC-01 SF-01 SF-01SF-01 WC-01WC-01 EQEQFULL TILEFULL TILE CT-01 RES-01 CPT-01 6 A-510 Sim 8 A-510 Sim 9 A-510 Sim 7 A-510 Sim PLANELEV DUPLEX OUTLET QUADPLEX OUTLET GFCI OUTLET CAT6, RJ45 INTERNET OUTLET TELEPHONE OUTLET WALL MOUNTED WIRELESS THERMOSTAT POWER OUTLET WITH USB PORTS CATV OUTLET ELECTRICAL SWITCH FLOOR OUTLET POWER AND SIGNAL LEGEND: POWER SUPPLY JUNCTION BOX DOOR BELL HARDWIRED TO DOORBELL LIGHT - MOUNT @ 46" A.F.F TO CENTER OF BUTTON (FOR COMMUNICATIONS FEATURES ROOMS ONLY) CEILING FIXTURE LEGEND: 6" RECESSED CAN DOWNLIGHT DECORATIVE FLUSH MOUNT LIGHT PENDENT TYPE SPRINKLERS SMOKE DETECTOR EXHAUST FAN / GRILLE LINEAR SURFACE MOUNTED CONTINUOUS LED SYSTEM W/ FIXED MOUNTING CLIPS & FROSTED LENS / 3 WATTS PER FOOT, MLV/FWD ELECTRICAL OUTLET HEIGHTS (U.N.O) TYPICAL OUTLET - 15" A.F.F TYPICAL ACCESSIBLE WALL OUTLET - 18" A.F.F BATHROOM VANITY OUTLET - 42" A.F.F TYP. KITCHEN OUTLET - 42" A.F.F ADA KITCHEN OUTLET - 46" A.F.F ADA BATHROOM VANITY OUTLET - 44" A.F.F ELECTRICAL SWITCH HEIGHTS (U.N.O) SWITCH - 44" A.F.F THERMOSTAT REMOTE - 48" A.F.F MAX TO TOP OF SWITCH SD 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216UNIT PLAN - KING1-BEDROOM ENLARGED- ELEC, DATA & FLOORFINISH PLAN A-419A FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 0'1' 2'4' SCALE: 1/2" = 1'-0" 1/2" = 1'-0" Reference: 1 / A-123 1KING 1-BEDROOM ENLARGED ELECTRICAL & DATA PLAN Units 201, 401, 501 1/2" = 1'-0"2 KING 1-BEDROOM ENLARGED FLOOR & WALL FINISH PLAN Units 201, 401, 501 3 7 12 8 9 11 13 15 10 17 16 16 FURNISHING SCHEDULE GUESTROOM FURNISHINGS GR-103 CHAIR - KITCHEN STOOL GR-108 SOFA - SECTIONAL SLEEPER GR-201 SCONCE - NIGHTSTAND GR-205 LAMP - FLOOR LAMP GR-308 NIGHTSTAND - REGULAR GR-312 TABLE - NESTING GR-315 TABLE - PRODUCTIVITY TABLE(1-BEDROOM) GR-316 CONSOLE - LIVING ROOM (1-BEDROOM) GR-317 DRESSER - BEDROOM (1-BEDROOM) GR-323 CLOSET - KING 1-BEDROOM SUITE GR-326 VANITY - STUDIO AND 1-BEDROOM SUITES GR-400 STATIC DRAPARY PANELS GR-503 ART- ENTRY GR-504 ART- SLEEPING/LIVING GR-506 MIRROR - GUESTROOM FULL LENGTH GR-508 MIRROR - GUESTROOM VANITY GR-800 KITCHENETTE - 1-BEDROOM GR-900 GUESTROOM REFRIGERATOR GR-901 GUESTROOM DISHWASHER GR-903 GUESTROOM COOKTOP - 4 BURNER GR-904 GARBAGE DISPOSAL 1/3HP GR-906GR-911 TELEVISION & TELEVISION MOUNT GR-907 CLOCK/RADIO FURNISHING SCHEDULE GR-908 TELEPHONE - GUESTROOM GR-909/910 GUESTROOM STACKED WASHER/DRYER GR-ES BED - EFFICIENCY (GR-300, 303, 600) PLUMBING/MECHANICAL FIXTURES PF-01 TOILET - GUESTROOM PF-03 SHOWER BASE - 60" X 36" WITH LINEARDRAIN PF-07 LAVATORY - UNDERMOUNT, 20" X 14" PF-11 SHOWER HEAD - 2 IN 1 PF-13 SHOWER/TUB VALVE & CONTROL PF-15 FAUCET - LAVATORY PF-40 SINK - KITCHENETTE PF-41 FAUCET - KITCHENETTE TOILET ACCESSORIES HD-01 DUAL TOILET PAPER HOLDER HD-04.1 TOWEL BAR HD-05.2 SLIDING SHOWER DOOR HD-08 18" GRAB BAR HD-16 BULK AMENITY DISPENSER ATSHOWERS/TUBS HD-18 FOOT LEDGE FOR SHOWER HD-18.1 SOAP SHELF HD-21 BULK AMENITY DISPENSER AT LAVATORIES KEYNOTES - UNIT PLANS 1 ALIGN 2 GENERAL CONTRACTOR TO COORDINATE W/ FURNITUREFABRICATOR WHERE NECESSARY TO PROVIDE PROPERBLOCKING IN WALL FOR ITEM KEYNOTED 3 NO FINISHES UNDER THE SHOWER PAN / TUB 4 NO FINISHES UNDER MILLWORK CABINETRY 5 TV AND MOUNT NOT TO PROJECT MORE THAN 4" FROMWALL 6 MOTORIZED BLINDS. PROVIDE JUNCTION BOX BEHINDVALENCE FOR POWER CONNECTION AND PERMANENTLYINSTALLED SWITCH ON WALL TO CONTROL BLINDS. 7 SWITCH CONTROLLING UNDER CABINET LIGHTING ATKITCHEN TO BE GANGED WITH LIGHTING AT ENTRY 8 SWITCH CONTROLLING GARBAGE DISPOSAL-REFER TOHADG FOR ACCESSIBLE ROOM REQ'S. 9 DEDICATED CIRCUIT FOR GARBAGE DISPOSAL 10 MASTER SWITCH 11 DEDICATED CIRCUIT FOR INDUCTION COOKTOP 12 DEDICATED CIRCUIT FOR DISHWASHER 13 DEDICATED CIRCUIT FOR REFRIGERATOR 14 ELECTRIC VANITY MIRROR - HARDWIRE FIXTURE TO WALL-CONTRACTOR TO VERIFY JBOX TYPE TO ENSURE PROPERINSTALLATION AND BACKING FOR ITEM KEYNOTED 15 DOORBELL AND DOORBELL ON/OFF SWITCH(COMMUNICATION FEATURES ROOMS ONLY)SIGNAGE ASREQ'D. 16 PLACE TV OUTLETS AND CONNECTIONS ON WALL OUTSIDEAREA OF BRACKET AND CONCEALED FROM VIEW BY TV 17 DEDICATED CIRCUIT FOR WASHER/DRYER. DIRECT VENTTO EXTERIOR EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV Revision Schedule Number Description Date TV SF-01 RB-01 WC-01 W-K PT-03PT-03 GR-403 GR-411GR-400GR-323 D-G04 GR-203 D-G05 SF-01 RB-01 W-H WD-01 GFCI GR-403 GR-403 GR-203 GR-400 GR-410 0' - 9" 4' - 6 3/4" PT-03PL-02 2' - 2 1/4" RB-01 WC-01WC-01 RB-10PT-03PL-02 GR-505 5' - 0"0' - 6 1/2" 0' - 8"5' - 1"4' - 2"GR-403 D-G03D-G02A 1' - 6"1' - 1"5' - 1 3/4"4' - 6"PT-11 PL-01 WC-01 RB-01 RB-10 WC-01 D-G01 GR-503 W-H SF-01 RB-01 GR-410 16 A-510 Sim GR-400 GR-403 WC-01 RB-01 GR-403 GR-ESGR-201 GR-308 PT-03 PT-035' - 0"EQEQ RB-01 WC-01 D-G05 GR-504 6' - 0 1/2" RB-01 WC-01 GR-317 GR-906GR-911 GR-505 5' - 0"WC-01 RB-01 D-G01 PLANELEV DUPLEX OUTLET QUADPLEX OUTLET GFCI OUTLET CAT6, RJ45 INTERNET OUTLET TELEPHONE OUTLET WALL MOUNTED WIRELESS THERMOSTAT POWER OUTLET WITH USB PORTS CATV OUTLET ELECTRICAL SWITCH FLOOR OUTLET POWER AND SIGNAL LEGEND: POWER SUPPLY JUNCTION BOX DOOR BELL HARDWIRED TO DOORBELL LIGHT - MOUNT @ 46" A.F.F TO CENTER OF BUTTON (FOR COMMUNICATIONS FEATURES ROOMS ONLY) CEILING FIXTURE LEGEND: 6" RECESSED CAN DOWNLIGHT DECORATIVE FLUSH MOUNT LIGHT PENDENT TYPE SPRINKLERS SMOKE DETECTOR EXHAUST FAN / GRILLE LINEAR SURFACE MOUNTED CONTINUOUS LED SYSTEM W/ FIXED MOUNTING CLIPS & FROSTED LENS / 3 WATTS PER FOOT, MLV/FWD ELECTRICAL OUTLET HEIGHTS (U.N.O) TYPICAL OUTLET - 15" A.F.F TYPICAL ACCESSIBLE WALL OUTLET - 18" A.F.F BATHROOM VANITY OUTLET - 42" A.F.F TYP. KITCHEN OUTLET - 42" A.F.F ADA KITCHEN OUTLET - 46" A.F.F ADA BATHROOM VANITY OUTLET - 44" A.F.F ELECTRICAL SWITCH HEIGHTS (U.N.O) SWITCH - 44" A.F.F THERMOSTAT REMOTE - 48" A.F.F MAX TO TOP OF SWITCH SD 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216UNIT INT. ELEVATIONS -KING 1-BEDROOMENLARGED A-419B FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 FFL FFL FFL 1/2" = 1'-0" Reference: 1 / A-419 1KING 1-BEDROOM ENLARGED ELEV. A Entry and Kitchen/Dining 1/2" = 1'-0" Reference: 1 / A-419 2 KING 1-BEDROOM ENLARGED ELEV. B Kitchen/Dining and Living 1/2" = 1'-0" Reference: 1 / A-419 3KING 1-BEDROOM ENLARGED ELEV. C Living and Entry 1/2" = 1'-0" Reference: 1 / A-419 4 KING 1-BEDROOM ENLARGED ELEV. D Living and Kitchen/Dining FFL 1/2" = 1'-0" Reference: 1 / A-419 6KING 1-BEDROOM ENLARGED ELEV. A2 Bedroom 1/2" = 1'-0" Reference: 1 / A-419 7KING 1-BEDROOM ENLARGED ELEV. B2 Bedroom 1/2" = 1'-0" Reference: 1 / A-419 8 KING 1-BEDROOM ENLARGED ELEV. C2 Bedroom 1/2" = 1'-0" Reference: 1 / A-419 9KING 1-BEDROOM ENLARGED ELEV. D2 Bedroom 1/2" = 1'-0" Reference: 1 / A-419 5KING 1-BEDROOM ENLARGED ELEV. D3 Entry Door 0'1' 2'4' SCALE: 1/2" = 1'-0" FURNISHING SCHEDULE GUESTROOM FURNISHINGS GR-100 CHAIR - LOUNGE CHAIR WITH OTTOMAN GR-102 CHAIR - COUNTER HEIGHT DESK CHAIR GR-103 CHAIR - KITCHEN STOOL GR-200 SCONCE - PIN-UP GR-201 SCONCE - NIGHTSTAND GR-203 PENDANT LIGHT - PRODUCTIVITY TABLE GR-204 CEILING LIGHT - 1-BEDROOM SUITE GR-205 LAMP - FLOOR LAMP GR-308 NIGHTSTAND - REGULAR GR-310 DESK - EFFICIENCY FURNISHING SCHEDULE GR-313 TABLE - ROUND SIDE TABLE GR-315 TABLE - PRODUCTIVITY TABLE (1-BEDROOM) GR-316 CONSOLE - LIVING ROOM (1-BEDROOM) GR-317 DRESSER - BEDROOM (1-BEDROOM) GR-319 CLOSET - EFFICIENCY SUITE GR-323 CLOSET - KING 1-BEDROOM SUITE GR-326 VANITY - STUDIO AND 1-BEDROOM SUITES GR-400 STATIC DRAPARY PANELS GR-403 ROLLER SHADE - GUESTROOMS (MANUAL,SHEER/BLACK-OUT, 8' W) KEYNOTES - UNIT PLANS 1 ALIGN 2 GENERAL CONTRACTOR TO COORDINATE W/ FURNITUREFABRICATOR WHERE NECESSARY TO PROVIDE PROPERBLOCKING IN WALL FOR ITEM KEYNOTED 3 NO FINISHES UNDER THE SHOWER PAN / TUB 4 NO FINISHES UNDER MILLWORK CABINETRY 5 TV AND MOUNT NOT TO PROJECT MORE THAN 4" FROMWALL 6 MOTORIZED BLINDS. PROVIDE JUNCTION BOX BEHINDVALENCE FOR POWER CONNECTION AND PERMANENTLYINSTALLED SWITCH ON WALL TO CONTROL BLINDS. 7 SWITCH CONTROLLING UNDER CABINET LIGHTING ATKITCHEN TO BE GANGED WITH LIGHTING AT ENTRY 8 SWITCH CONTROLLING GARBAGE DISPOSAL-REFER TOHADG FOR ACCESSIBLE ROOM REQ'S. 9 DEDICATED CIRCUIT FOR GARBAGE DISPOSAL 10 MASTER SWITCH 11 DEDICATED CIRCUIT FOR INDUCTION COOKTOP 12 DEDICATED CIRCUIT FOR DISHWASHER 13 DEDICATED CIRCUIT FOR REFRIGERATOR 14 ELECTRIC VANITY MIRROR - HARDWIRE FIXTURE TO WALL-CONTRACTOR TO VERIFY JBOX TYPE TO ENSURE PROPERINSTALLATION AND BACKING FOR ITEM KEYNOTED 15 DOORBELL AND DOORBELL ON/OFF SWITCH(COMMUNICATION FEATURES ROOMS ONLY)SIGNAGE ASREQ'D. 16 PLACE TV OUTLETS AND CONNECTIONS ON WALL OUTSIDEAREA OF BRACKET AND CONCEALED FROM VIEW BY TV 17 DEDICATED CIRCUIT FOR WASHER/DRYER. DIRECT VENTTO EXTERIOR FURNISHING SCHEDULE GR-410 VALENCE FOR 5' WINDOW GR-411 VALENCE FOR 5' WINDOW - ONE DRAPERYPANEL GR-503 ART- ENTRY GR-504 ART- SLEEPING/LIVING GR-505 WALL HOOK GR-506 MIRROR - GUESTROOM FULL LENGTH GR-508 MIRROR - GUESTROOM VANITY GR-800 KITCHENETTE - 1-BEDROOM GR-802 KITCHENETTE - EFFICIENCY SUITE GR-900 GUESTROOM REFRIGERATOR GR-901 GUESTROOM DISHWASHER GR-902 GUESTROOM COOKTOP - 2 BURNER GR-903 GUESTROOM COOKTOP - 4 BURNER GR-904 GARBAGE DISPOSAL 1/3HP GR-905 MICROWAVE- WITH RECIRCULATING HOOD GR-906GR-911 TELEVISION & TELEVISION MOUNT GR-907 CLOCK/RADIO GR-908 TELEPHONE - GUESTROOM GR-909/910 GUESTROOM STACKED WASHER/DRYER GR-ES BED - EFFICIENCY (GR-300, 303, 600) GR-KS BED - KING (GR-301, 303, 600) HILTON SPECIFIED - OWNER FURNISHED OF-702A CHAIR - BALCONY CHAIR OF-705 TABLE - 17" D OUTDOOR SIDE TABLE FURNISHING SCHEDULE OWNER SPECIFIED - OWNER FURNISHED OP-706 FIRE EXTINGUISHER CABINET PLUMBING/MECHANICAL FIXTURES PF-01 TOILET - GUESTROOM PF-03 SHOWER BASE - 60" X 36" WITH LINEAR DRAIN PF-07 LAVATORY - UNDERMOUNT, 20" X 14" PF-11 SHOWER HEAD - 2 IN 1 PF-13 SHOWER/TUB VALVE & CONTROL PF-15 FAUCET - LAVATORY PF-40 SINK - KITCHENETTE PF-41 FAUCET - KITCHENETTE TOILET ACCESSORIES HD-01 DUAL TOILET PAPER HOLDER HD-04 WALL-MOUNTED ROBE HOOK HD-04.1 TOWEL BAR HD-05.2 SLIDING SHOWER DOOR HD-08 18" GRAB BAR HD-16 BULK AMENITY DISPENSER AT SHOWERS/TUBS HD-18 FOOT LEDGE FOR SHOWER HD-18.1 SOAP SHELF HD-21 BULK AMENITY DISPENSER AT LAVATORIES EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV Revision Schedule Number Description Date MMAASD TVTV A-420B2 1 4 3 D-G02 GR-908 GR-907 D-G026' - 9 3/4"6' - 9 3/4"29' - 5 1/2"6' - 1" D-G01 D-G03 D-G03 W-G GR-QS GR-QS GR-307 GR-308 GR-201 GR-206 GR-307 GR-206 GR-908 GR-907 GR-103 GR-103 GR-318 GR-312 GR-101 GR-205 GR-313 GR-105 GR-326 GR-906GR-911 18' - 5" GR-400GR-400 GR-201 GR-321 GR-506 ALIGN GR-314 GR-504 GR-508 P3.1 A-4252 OF-705OF-702AOF-702A CL-B8' - 0" GR-412 GR-400GR-400 CL-B27' - 6" CL-A8' - 0" CL-B27' - 6"EQEQ3' - 2" 1 1 1 GR-203 GR-203 1 1 1 1 1 EQ EQ EQ EQ 7' - 7"5' - 2"1' - 5"8' - 4 1/4" 5' - 6"3' - 8 3/4" OF-702 OF-705 OF-702 PLAN ELEV DUPLEX OUTLET QUADPLEX OUTLET GFCI OUTLET CAT6, RJ45 INTERNET OUTLET TELEPHONE OUTLET WALL MOUNTED WIRELESS THERMOSTAT POWER OUTLET WITH USB PORTS CATV OUTLET ELECTRICAL SWITCH FLOOR OUTLET POWER AND SIGNAL LEGEND: POWER SUPPLY CEILING FIXTURE LEGEND: 6" RECESSED CAN DOWNLIGHT DECORATIVE FLUSH MOUNT LIGHT PENDENT TYPE SPRINKLERS SMOKE DETECTOR EXHAUST FAN / GRILLE LINEAR SURFACE MOUNTED CONTINUOUS LED SYSTEM W/ FIXED MOUNTING CLIPS & FROSTED LENS / 3 WATTS PER FOOT, MLV/FWD ELECTRICAL OUTLET HEIGHTS (U.N.O) TYPICAL OUTLET - 15" A.F.F TYPICAL ACCESSIBLE WALL OUTLET - 18" A.F.F BATHROOM VANITY OUTLET - 42" A.F.F TYP. KITCHEN OUTLET - 42" A.F.F ADA KITCHEN OUTLET - 46" A.F.F ADA BATHROOM VANITY OUTLET - 44" A.F.F ELECTRICAL SWITCH HEIGHTS (U.N.O) SWITCH - 44" A.F.F THERMOSTAT REMOTE - 48" A.F.F MAX TO TOP OF SWITCH JUNCTION BOX DOOR BELL HARDWIRED TO DOORBELL LIGHT - MOUNT @ 46" A.F.F TO CENTER OF BUTTON (FOR COMMUNICATIONS FEATURES ROOMS ONLY) SD 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216UNIT PLAN - DOUBLEQUEEN STUDIO A-420 FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 1/2" = 1'-0" Reference: 1 / A-102 1DOUBLE QUEEN STUDIO CONSTRUCTION PLAN Units x10, x22, x24, x35-x36 1/2" = 1'-0" Reference: 1 / A-102 2DOUBLE QUEEN STUDIO BALCONY PLAN Units 235, 335, 435, 535 1/2" = 1'-0"3DOUBLE QUEEN STUDIO RCP Units x10, x22, x24, x35-x36 1/2" = 1'-0" Reference: 1 / A-101 4DOUBLE QUEEN STUDIO LANAI PLAN Unit 135 0'1' 2'4' SCALE: 1/2" = 1'-0" 2 5 2 2 2 2 KEYNOTES - UNIT PLANS 1 ALIGN 2 GENERAL CONTRACTOR TO COORDINATE W/ FURNITUREFABRICATOR WHERE NECESSARY TO PROVIDE PROPERBLOCKING IN WALL FOR ITEM KEYNOTED 3 NO FINISHES UNDER THE SHOWER PAN / TUB 4 NO FINISHES UNDER MILLWORK CABINETRY 5 TV AND MOUNT NOT TO PROJECT MORE THAN 4" FROMWALL 6 MOTORIZED BLINDS. PROVIDE JUNCTION BOX BEHINDVALENCE FOR POWER CONNECTION AND PERMANENTLYINSTALLED SWITCH ON WALL TO CONTROL BLINDS. 7 SWITCH CONTROLLING UNDER CABINET LIGHTING ATKITCHEN TO BE GANGED WITH LIGHTING AT ENTRY 8 SWITCH CONTROLLING GARBAGE DISPOSAL-REFER TOHADG FOR ACCESSIBLE ROOM REQ'S. 9 DEDICATED CIRCUIT FOR GARBAGE DISPOSAL 10 MASTER SWITCH 11 DEDICATED CIRCUIT FOR INDUCTION COOKTOP 12 DEDICATED CIRCUIT FOR DISHWASHER 13 DEDICATED CIRCUIT FOR REFRIGERATOR 14 ELECTRIC VANITY MIRROR - HARDWIRE FIXTURE TO WALL-CONTRACTOR TO VERIFY JBOX TYPE TO ENSURE PROPERINSTALLATION AND BACKING FOR ITEM KEYNOTED 15 DOORBELL AND DOORBELL ON/OFF SWITCH(COMMUNICATION FEATURES ROOMS ONLY)SIGNAGE ASREQ'D. 16 PLACE TV OUTLETS AND CONNECTIONS ON WALL OUTSIDEAREA OF BRACKET AND CONCEALED FROM VIEW BY TV 17 DEDICATED CIRCUIT FOR WASHER/DRYER. DIRECT VENTTO EXTERIOR FURNISHING SCHEDULE GUESTROOM FURNISHINGS GR-101 CHAIR - LOUNGE CHAIR IN STUIDOS GR-103 CHAIR - KITCHEN STOOL GR-105 SOFA - SLEEP BETWEEN ARMS GR-201 SCONCE - NIGHTSTAND GR-203 PENDANT LIGHT - PRODUCTIVITY TABLE GR-205 LAMP - FLOOR LAMP GR-206 LAMP - DOUBLE QUEEN READING LAMP GR-307 NIGHTSTAND - SMALL GR-308 NIGHTSTAND - REGULAR GR-312 TABLE - NESTING GR-313 TABLE - ROUND SIDE TABLE GR-314 TABLE - PRODUCTIVITY TABLE (STUDIO) GR-318 DRESSER - HIGHBOY GR-321 CLOSET - KING STUDIO SUITE GR-326 VANITY - STUDIO AND 1-BEDROOM SUITES GR-400 STATIC DRAPARY PANELS GR-402 ROLLER SHADE - GUESTROOMS (MANUAL,SHEER/BLACK-OUT, 5' W) GR-412 VALENCE FOR 8' WINDOW GR-502 ART GR-504 ART- SLEEPING/LIVING GR-506 MIRROR - GUESTROOM FULL LENGTH GR-508 MIRROR - GUESTROOM VANITY GR-800 KITCHENETTE - 1-BEDROOM GR-900 GUESTROOM REFRIGERATOR GR-901 GUESTROOM DISHWASHER GR-902 GUESTROOM COOKTOP - 2 BURNER GR-904 GARBAGE DISPOSAL 1/3HP GR-905 MICROWAVE- WITH RECIRCULATING HOOD GR-906GR-911 TELEVISION & TELEVISION MOUNT GR-907 CLOCK/RADIO GR-908 TELEPHONE - GUESTROOM GR-QS BED - QUEEN (GR-302, 305, 601) HILTON SPECIFIED - OWNER FURNISHED OF-702 CHAIR - OUDOOR DINING CHAIR OF-702A CHAIR - BALCONY CHAIR OF-705 TABLE - 17" D OUTDOOR SIDE TABLE OWNER SPECIFIED - OWNER FURNISHED OP-706 FIRE EXTINGUISHER CABINET PLUMBING/MECHANICAL FIXTURES PF-01 TOILET - GUESTROOM PF-06 BATHTUB - 5' X 32" WITH SIDE LEDGE PF-07 LAVATORY - UNDERMOUNT, 20" X 14" PF-11 SHOWER HEAD - 2 IN 1 PF-13 SHOWER/TUB VALVE & CONTROL PF-14 BATHTUB FILL FAUCET PF-15 FAUCET - LAVATORY PF-40 SINK - KITCHENETTE PF-41 FAUCET - KITCHENETTE TOILET ACCESSORIES HD-01 DUAL TOILET PAPER HOLDER HD-04 WALL-MOUNTED ROBE HOOK HD-04.1 TOWEL BAR HD-05 CURVED CURTAIN ROD AND SHOWERCURTAIN HD-08 18" GRAB BAR HD-16 BULK AMENITY DISPENSER ATSHOWERS/TUBS HD-18.1 SOAP SHELF HD-21 BULK AMENITY DISPENSER AT LAVATORIES EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV Revision Schedule Number Description Date TVTV A-420B2 1 4 3 GFCI SF-01 WC-01 WC-01 WC-01 WC-01 WC-01 CPT-10 CPT-01 RES-01 CT-01 9 A-510 Sim 7 A-510 Sim 1 A-510 Sim FULL TILE FULL TILE17' - 8 3/4"8' - 5 3/4"FULL TILEFULL TILE 6 A-510 Sim PLAN ELEV DUPLEX OUTLET QUADPLEX OUTLET GFCI OUTLET CAT6, RJ45 INTERNET OUTLET TELEPHONE OUTLET WALL MOUNTED WIRELESS THERMOSTAT POWER OUTLET WITH USB PORTS CATV OUTLET ELECTRICAL SWITCH FLOOR OUTLET POWER AND SIGNAL LEGEND: POWER SUPPLY CEILING FIXTURE LEGEND: 6" RECESSED CAN DOWNLIGHT DECORATIVE FLUSH MOUNT LIGHT PENDENT TYPE SPRINKLERS SMOKE DETECTOR EXHAUST FAN / GRILLE LINEAR SURFACE MOUNTED CONTINUOUS LED SYSTEM W/ FIXED MOUNTING CLIPS & FROSTED LENS / 3 WATTS PER FOOT, MLV/FWD ELECTRICAL OUTLET HEIGHTS (U.N.O) TYPICAL OUTLET - 15" A.F.F TYPICAL ACCESSIBLE WALL OUTLET - 18" A.F.F BATHROOM VANITY OUTLET - 42" A.F.F TYP. KITCHEN OUTLET - 42" A.F.F ADA KITCHEN OUTLET - 46" A.F.F ADA BATHROOM VANITY OUTLET - 44" A.F.F ELECTRICAL SWITCH HEIGHTS (U.N.O) SWITCH - 44" A.F.F THERMOSTAT REMOTE - 48" A.F.F MAX TO TOP OF SWITCH JUNCTION BOX DOOR BELL HARDWIRED TO DOORBELL LIGHT - MOUNT @ 46" A.F.F TO CENTER OF BUTTON (FOR COMMUNICATIONS FEATURES ROOMS ONLY) SD 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216UNIT PLAN - DOUBLEQUEEN STUDIO - ELEC,DATA & FLOOR FINISHPLAN A-420A FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 0'1' 2'4' SCALE: 1/2" = 1'-0" 1/2" = 1'-0"1DOUBLE QUEEN STUDIO UNIT ELECTRICAL & DATA PLAN Units x10, x22, x24, x35-x36 1/2" = 1'-0"2DOUBLE QUEEN STUDIO UNIT FLOOR & WALL FINISH PLAN Units x10, x22, x24, x35-x36 15 10 12 8 9 11 13 16 14 3 KEYNOTES - UNIT PLANS 1 ALIGN 2 GENERAL CONTRACTOR TO COORDINATE W/ FURNITUREFABRICATOR WHERE NECESSARY TO PROVIDE PROPERBLOCKING IN WALL FOR ITEM KEYNOTED 3 NO FINISHES UNDER THE SHOWER PAN / TUB 4 NO FINISHES UNDER MILLWORK CABINETRY 5 TV AND MOUNT NOT TO PROJECT MORE THAN 4" FROMWALL 6 MOTORIZED BLINDS. PROVIDE JUNCTION BOX BEHINDVALENCE FOR POWER CONNECTION AND PERMANENTLYINSTALLED SWITCH ON WALL TO CONTROL BLINDS. 7 SWITCH CONTROLLING UNDER CABINET LIGHTING ATKITCHEN TO BE GANGED WITH LIGHTING AT ENTRY 8 SWITCH CONTROLLING GARBAGE DISPOSAL-REFER TOHADG FOR ACCESSIBLE ROOM REQ'S. 9 DEDICATED CIRCUIT FOR GARBAGE DISPOSAL 10 MASTER SWITCH 11 DEDICATED CIRCUIT FOR INDUCTION COOKTOP 12 DEDICATED CIRCUIT FOR DISHWASHER 13 DEDICATED CIRCUIT FOR REFRIGERATOR 14 ELECTRIC VANITY MIRROR - HARDWIRE FIXTURE TO WALL-CONTRACTOR TO VERIFY JBOX TYPE TO ENSURE PROPERINSTALLATION AND BACKING FOR ITEM KEYNOTED 15 DOORBELL AND DOORBELL ON/OFF SWITCH(COMMUNICATION FEATURES ROOMS ONLY)SIGNAGE ASREQ'D. 16 PLACE TV OUTLETS AND CONNECTIONS ON WALL OUTSIDEAREA OF BRACKET AND CONCEALED FROM VIEW BY TV 17 DEDICATED CIRCUIT FOR WASHER/DRYER. DIRECT VENTTO EXTERIOR FURNISHING SCHEDULE GUESTROOM FURNISHINGS GR-101 CHAIR - LOUNGE CHAIR IN STUIDOS GR-103 CHAIR - KITCHEN STOOL GR-105 SOFA - SLEEP BETWEEN ARMS GR-201 SCONCE - NIGHTSTAND GR-205 LAMP - FLOOR LAMP GR-206 LAMP - DOUBLE QUEEN READING LAMP GR-307 NIGHTSTAND - SMALL GR-308 NIGHTSTAND - REGULAR GR-312 TABLE - NESTING GR-313 TABLE - ROUND SIDE TABLE GR-314 TABLE - PRODUCTIVITY TABLE (STUDIO) GR-318 DRESSER - HIGHBOY GR-321 CLOSET - KING STUDIO SUITE GR-326 VANITY - STUDIO AND 1-BEDROOM SUITES GR-400 STATIC DRAPARY PANELS GR-504 ART- SLEEPING/LIVING GR-506 MIRROR - GUESTROOM FULL LENGTH GR-508 MIRROR - GUESTROOM VANITY GR-800 KITCHENETTE - 1-BEDROOM GR-900 GUESTROOM REFRIGERATOR GR-901 GUESTROOM DISHWASHER GR-902 GUESTROOM COOKTOP - 2 BURNER GR-904 GARBAGE DISPOSAL 1/3HP GR-906GR-911 TELEVISION & TELEVISION MOUNT GR-907 CLOCK/RADIO GR-908 TELEPHONE - GUESTROOM GR-QS BED - QUEEN (GR-302, 305, 601) OWNER SPECIFIED - OWNER FURNISHED OP-706 FIRE EXTINGUISHER CABINET PLUMBING/MECHANICAL FIXTURES PF-01 TOILET - GUESTROOM PF-06 BATHTUB - 5' X 32" WITH SIDE LEDGE PF-07 LAVATORY - UNDERMOUNT, 20" X 14" PF-11 SHOWER HEAD - 2 IN 1 PF-13 SHOWER/TUB VALVE & CONTROL PF-14 BATHTUB FILL FAUCET PF-15 FAUCET - LAVATORY PF-40 SINK - KITCHENETTE PF-41 FAUCET - KITCHENETTE TOILET ACCESSORIES HD-01 DUAL TOILET PAPER HOLDER HD-04.1 TOWEL BAR HD-08 18" GRAB BAR HD-16 BULK AMENITY DISPENSER ATSHOWERS/TUBS HD-18.1 SOAP SHELF HD-21 BULK AMENITY DISPENSER AT LAVATORIES EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV Revision Schedule Number Description Date TV 5' - 0"D-G01 PT-11PL-01WC-01WC-01 4' - 2" GR-203 WD-01 WD-01 WC-01 4' - 0 3/4" PT-03 PL-02 WC-01 GR-905 GR-901 GR-900 GR-902 D-G02 WD-01 WC-01 0' - 9"4' - 2"5' - 1"GR-906GR-911 P3.2 G-006 GR-205 SF-01 GR-412 PT-03 16 A-510 Sim W-G GR-400 GR-402 WC-01 D-G03 5' - 2"2' - 3"3' - 2"0' - 6"PLANELEV DUPLEX OUTLET QUADPLEX OUTLET GFCI OUTLET CAT6, RJ45 INTERNET OUTLET TELEPHONE OUTLET WALL MOUNTED WIRELESS THERMOSTAT POWER OUTLET WITH USB PORTS CATV OUTLET ELECTRICAL SWITCH FLOOR OUTLET POWER AND SIGNAL LEGEND: POWER SUPPLY JUNCTION BOX DOOR BELL HARDWIRED TO DOORBELL LIGHT - MOUNT @ 46" A.F.F TO CENTER OF BUTTON (FOR COMMUNICATIONS FEATURES ROOMS ONLY) CEILING FIXTURE LEGEND: 6" RECESSED CAN DOWNLIGHT DECORATIVE FLUSH MOUNT LIGHT PENDENT TYPE SPRINKLERS SMOKE DETECTOR EXHAUST FAN / GRILLE LINEAR SURFACE MOUNTED CONTINUOUS LED SYSTEM W/ FIXED MOUNTING CLIPS & FROSTED LENS / 3 WATTS PER FOOT, MLV/FWD ELECTRICAL OUTLET HEIGHTS (U.N.O) TYPICAL OUTLET - 15" A.F.F TYPICAL ACCESSIBLE WALL OUTLET - 18" A.F.F BATHROOM VANITY OUTLET - 42" A.F.F TYP. KITCHEN OUTLET - 42" A.F.F ADA KITCHEN OUTLET - 46" A.F.F ADA BATHROOM VANITY OUTLET - 44" A.F.F ELECTRICAL SWITCH HEIGHTS (U.N.O) SWITCH - 44" A.F.F THERMOSTAT REMOTE - 48" A.F.F MAX TO TOP OF SWITCH SD 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216UNIT INT. ELEVATION -DOUBLE QUEEN STUDIO A-420B FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 FFL FFL 1/2" = 1'-0" Reference: 1 / A-420 1DOUBLE QUEEN STUDIO ELEVATION A Units x10, x22, x24, x35-x36 1/2" = 1'-0" Reference: 1 / A-420 2DOUBLE QUEEN STUDIO ELEVATION B Units x10, x22, x24, x35-x36 1/2" = 1'-0" Reference: 1 / A-420 3DOUBLE QUEEN STUDIO ELEVATION C Units x10, x22, x24, x35-x36 1/2" = 1'-0" Reference: 1 / A-420 4DOUBLE QUEEN STUDIO ELEVATION D Units x10, x22, x24, x35-x36 FURNISHING SCHEDULE GUESTROOM FURNISHINGS GR-101 CHAIR - LOUNGE CHAIR IN STUIDOS GR-103 CHAIR - KITCHEN STOOL GR-105 SOFA - SLEEP BETWEEN ARMS GR-201 SCONCE - NIGHTSTAND GR-203 PENDANT LIGHT - PRODUCTIVITY TABLE GR-205 LAMP - FLOOR LAMP GR-206 LAMP - DOUBLE QUEEN READING LAMP GR-307 NIGHTSTAND - SMALL GR-308 NIGHTSTAND - REGULAR GR-312 TABLE - NESTING GR-313 TABLE - ROUND SIDE TABLE GR-314 TABLE - PRODUCTIVITY TABLE (STUDIO) GR-318 DRESSER - HIGHBOY GR-321 CLOSET - KING STUDIO SUITE GR-326 VANITY - STUDIO AND 1-BEDROOM SUITES GR-400 STATIC DRAPARY PANELS GR-402 ROLLER SHADE - GUESTROOMS (MANUAL,SHEER/BLACK-OUT, 5' W) GR-403 ROLLER SHADE - GUESTROOMS (MANUAL,SHEER/BLACK-OUT, 8' W) GR-412 VALENCE FOR 8' WINDOW GR-502 ART GR-503 ART- ENTRY GR-504 ART- SLEEPING/LIVING GR-505 WALL HOOK GR-506 MIRROR - GUESTROOM FULL LENGTH FURNISHING SCHEDULE GR-508 MIRROR - GUESTROOM VANITY GR-800 KITCHENETTE - 1-BEDROOM GR-900 GUESTROOM REFRIGERATOR GR-901 GUESTROOM DISHWASHER GR-902 GUESTROOM COOKTOP - 2 BURNER GR-904 GARBAGE DISPOSAL 1/3HP GR-905 MICROWAVE- WITH RECIRCULATING HOOD GR-906GR-911 TELEVISION & TELEVISION MOUNT GR-907 CLOCK/RADIO GR-908 TELEPHONE - GUESTROOM GR-KS BED - KING (GR-301, 303, 600) GR-QS BED - QUEEN (GR-302, 305, 601) OWNER SPECIFIED - OWNER FURNISHED OP-706 FIRE EXTINGUISHER CABINET PLUMBING/MECHANICAL FIXTURES PF-01 TOILET - GUESTROOM PF-03 SHOWER BASE - 60" X 36" WITH LINEARDRAIN PF-06 BATHTUB - 5' X 32" WITH SIDE LEDGE PF-07 LAVATORY - UNDERMOUNT, 20" X 14" PF-11 SHOWER HEAD - 2 IN 1 PF-13 SHOWER/TUB VALVE & CONTROL PF-14 BATHTUB FILL FAUCET PF-15 FAUCET - LAVATORY KEYNOTES - UNIT PLANS 1 ALIGN 2 GENERAL CONTRACTOR TO COORDINATE W/ FURNITUREFABRICATOR WHERE NECESSARY TO PROVIDE PROPERBLOCKING IN WALL FOR ITEM KEYNOTED 3 NO FINISHES UNDER THE SHOWER PAN / TUB 4 NO FINISHES UNDER MILLWORK CABINETRY 5 TV AND MOUNT NOT TO PROJECT MORE THAN 4" FROMWALL 6 MOTORIZED BLINDS. PROVIDE JUNCTION BOX BEHINDVALENCE FOR POWER CONNECTION AND PERMANENTLYINSTALLED SWITCH ON WALL TO CONTROL BLINDS. 7 SWITCH CONTROLLING UNDER CABINET LIGHTING ATKITCHEN TO BE GANGED WITH LIGHTING AT ENTRY 8 SWITCH CONTROLLING GARBAGE DISPOSAL-REFER TOHADG FOR ACCESSIBLE ROOM REQ'S. 9 DEDICATED CIRCUIT FOR GARBAGE DISPOSAL 10 MASTER SWITCH 11 DEDICATED CIRCUIT FOR INDUCTION COOKTOP 12 DEDICATED CIRCUIT FOR DISHWASHER 13 DEDICATED CIRCUIT FOR REFRIGERATOR 14 ELECTRIC VANITY MIRROR - HARDWIRE FIXTURE TO WALL-CONTRACTOR TO VERIFY JBOX TYPE TO ENSURE PROPERINSTALLATION AND BACKING FOR ITEM KEYNOTED 15 DOORBELL AND DOORBELL ON/OFF SWITCH(COMMUNICATION FEATURES ROOMS ONLY)SIGNAGE ASREQ'D. 16 PLACE TV OUTLETS AND CONNECTIONS ON WALL OUTSIDEAREA OF BRACKET AND CONCEALED FROM VIEW BY TV 17 DEDICATED CIRCUIT FOR WASHER/DRYER. DIRECT VENTTO EXTERIOR FURNISHING SCHEDULE PF-40 SINK - KITCHENETTE PF-41 FAUCET - KITCHENETTE TOILET ACCESSORIES HD-01 DUAL TOILET PAPER HOLDER HD-04 WALL-MOUNTED ROBE HOOK HD-04.1 TOWEL BAR HD-05 CURVED CURTAIN ROD AND SHOWERCURTAIN HD-05.2 SLIDING SHOWER DOOR HD-08 18" GRAB BAR HD-16 BULK AMENITY DISPENSER ATSHOWERS/TUBS HD-18 FOOT LEDGE FOR SHOWER HD-18.1 SOAP SHELF HD-21 BULK AMENITY DISPENSER AT LAVATORIES EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV Revision Schedule Number Description Date MAATVSD TV A-421B2 1 3 4 A-424 2 D-G01A W-GXE1/2 D-G03A12' - 5 3/4"18' - 0 1/4"9' - 9 1/4"9' - 1 1/4"4' - 9"11' - 2 1/2"7' - 8 1/2" 7' - 1 1/4" 0' - 6 1/2"11' - 2 1/2" GR-103 GR-103 GR-105GR-312 GR-205 GR-101GR-313 GR-QM GR-QM GR-206 GR-201 GR-201 GR-308 GR-206 GR-907 GR-908GR-906GR-911 XE1/2 D-G02A P3.1 GR-503 GR-322 GR-507 GR-400 GR-400 CL-B27' - 6" CL-B8' - 0" 4' - 2"4' - 2"5' - 2"7' - 7"5' - 2"1 1 1 1 2' - 8"2' - 11 1/4"3' - 8"2' - 6"3' - 6 1/2"4' - 0"1 1 1 PLAN ELEV DUPLEX OUTLET QUADPLEX OUTLET GFCI OUTLET CAT6, RJ45 INTERNET OUTLET TELEPHONE OUTLET WALL MOUNTED WIRELESS THERMOSTAT POWER OUTLET WITH USB PORTS CATV OUTLET ELECTRICAL SWITCH FLOOR OUTLET POWER AND SIGNAL LEGEND: POWER SUPPLY CEILING FIXTURE LEGEND: 6" RECESSED CAN DOWNLIGHT DECORATIVE FLUSH MOUNT LIGHT PENDENT TYPE SPRINKLERS SMOKE DETECTOR EXHAUST FAN / GRILLE LINEAR SURFACE MOUNTED CONTINUOUS LED SYSTEM W/ FIXED MOUNTING CLIPS & FROSTED LENS / 3 WATTS PER FOOT, MLV/FWD ELECTRICAL OUTLET HEIGHTS (U.N.O) TYPICAL OUTLET - 15" A.F.F TYPICAL ACCESSIBLE WALL OUTLET - 18" A.F.F BATHROOM VANITY OUTLET - 42" A.F.F TYP. KITCHEN OUTLET - 42" A.F.F ADA KITCHEN OUTLET - 46" A.F.F ADA BATHROOM VANITY OUTLET - 44" A.F.F ELECTRICAL SWITCH HEIGHTS (U.N.O) SWITCH - 44" A.F.F THERMOSTAT REMOTE - 48" A.F.F MAX TO TOP OF SWITCH JUNCTION BOX DOOR BELL HARDWIRED TO DOORBELL LIGHT - MOUNT @ 46" A.F.F TO CENTER OF BUTTON (FOR COMMUNICATIONS FEATURES ROOMS ONLY) SD 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216UNIT PLAN - DOUBLEQUEEN STUDIO ADAMOBILITY A-421 FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 0'1' 2'4' SCALE: 1/2" = 1'-0" 1/2" = 1'-0" Reference: 1 / A-105 1DOUBLE QUEEN STUDIO ADA MOBILITY CONSTRUCTION PLAN Unit 512 1/2" = 1'-0" Reference: 1 / x-115 2DOUBLE QUEEN STUDIO ADA MOBILITY RCP Unit 512 2 2 5 2 2 KEYNOTES - UNIT PLANS 1 ALIGN 2 GENERAL CONTRACTOR TO COORDINATE W/ FURNITUREFABRICATOR WHERE NECESSARY TO PROVIDE PROPERBLOCKING IN WALL FOR ITEM KEYNOTED 3 NO FINISHES UNDER THE SHOWER PAN / TUB 4 NO FINISHES UNDER MILLWORK CABINETRY 5 TV AND MOUNT NOT TO PROJECT MORE THAN 4" FROMWALL 6 MOTORIZED BLINDS. PROVIDE JUNCTION BOX BEHINDVALENCE FOR POWER CONNECTION AND PERMANENTLYINSTALLED SWITCH ON WALL TO CONTROL BLINDS. 7 SWITCH CONTROLLING UNDER CABINET LIGHTING ATKITCHEN TO BE GANGED WITH LIGHTING AT ENTRY 8 SWITCH CONTROLLING GARBAGE DISPOSAL-REFER TOHADG FOR ACCESSIBLE ROOM REQ'S. 9 DEDICATED CIRCUIT FOR GARBAGE DISPOSAL 10 MASTER SWITCH 11 DEDICATED CIRCUIT FOR INDUCTION COOKTOP 12 DEDICATED CIRCUIT FOR DISHWASHER 13 DEDICATED CIRCUIT FOR REFRIGERATOR 14 ELECTRIC VANITY MIRROR - HARDWIRE FIXTURE TO WALL-CONTRACTOR TO VERIFY JBOX TYPE TO ENSURE PROPERINSTALLATION AND BACKING FOR ITEM KEYNOTED 15 DOORBELL AND DOORBELL ON/OFF SWITCH(COMMUNICATION FEATURES ROOMS ONLY)SIGNAGE ASREQ'D. 16 PLACE TV OUTLETS AND CONNECTIONS ON WALL OUTSIDEAREA OF BRACKET AND CONCEALED FROM VIEW BY TV 17 DEDICATED CIRCUIT FOR WASHER/DRYER. DIRECT VENTTO EXTERIOR FURNISHING SCHEDULE GUESTROOM FURNISHINGS GR-101 CHAIR - LOUNGE CHAIR IN STUIDOS GR-103 CHAIR - KITCHEN STOOL GR-105 SOFA - SLEEP BETWEEN ARMS GR-201 SCONCE - NIGHTSTAND GR-203 PENDANT LIGHT - PRODUCTIVITY TABLE GR-205 LAMP - FLOOR LAMP GR-206 LAMP - DOUBLE QUEEN READING LAMP GR-308 NIGHTSTAND - REGULAR GR-312 TABLE - NESTING GR-313 TABLE - ROUND SIDE TABLE GR-314 TABLE - PRODUCTIVITY TABLE (STUDIO) GR-322 CLOSET - ACCESSIBLE KING STUDIO SUITE GR-327 VANITY - ACCESSIBLE SUITES GR-328 BATH CADDY - ACCESSIBLE SUITES GR-400 STATIC DRAPARY PANELS GR-403 ROLLER SHADE - GUESTROOMS (MANUAL,SHEER/BLACK-OUT, 8' W) GR-412 VALENCE FOR 8' WINDOW GR-503 ART- ENTRY GR-506 MIRROR - GUESTROOM FULL LENGTH GR-507 MIRROR - ADA VANITY GR-800 KITCHENETTE - 1-BEDROOM GR-900 GUESTROOM REFRIGERATOR GR-901 GUESTROOM DISHWASHER GR-902 GUESTROOM COOKTOP - 2 BURNER GR-906GR-911 TELEVISION & TELEVISION MOUNT GR-907 CLOCK/RADIO GR-908 TELEPHONE - GUESTROOM GR-912 RECIRCULATING HOOD GR-QM BED - QUEEN MOBILITY (GR-302, 306, 601,603) PLUMBING/MECHANICAL FIXTURES PF-01 TOILET - GUESTROOM PF-06 BATHTUB - 5' X 32" WITH SIDE LEDGE PF-07 LAVATORY - UNDERMOUNT, 20" X 14" PF-10 SHOWER HEAD - HIGH PF-12 SHOWER HEAD - HAND HELD ON SLIDE BAR PF-13 SHOWER/TUB VALVE & CONTROL PF-14 BATHTUB FILL FAUCET PF-15 FAUCET - LAVATORY PF-41 FAUCET - KITCHENETTE PF-42 SINK - ADA KITCHENETTE TOILET ACCESSORIES HD-02 DUAL TOILET PAPER HOLDER- ADA HD-04 WALL-MOUNTED ROBE HOOK HD-04.1 TOWEL BAR HD-05 CURVED CURTAIN ROD AND SHOWERCURTAIN HD-08 18" GRAB BAR HD-09 24" GRAB BAR HD-10 42" GRAB BAR AT ADA BATHTUB HD-11 36" GRAB BAR HD-11.1 42" GRAB BAR HD-14.1 ROLL-IN SHOWER SEAT HD-16 BULK AMENITY DISPENSER ATSHOWERS/TUBS HD-18.1 SOAP SHELF HD-20 12" GRAB BAR HD-21 BULK AMENITY DISPENSER AT LAVATORIES EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV Revision Schedule Number Description Date TVTV A-421B2 1 3 4 RES-01 CPT-01 CT-01 SF-01 WC-01 WC-01 WC-01 WC-01 FULL TILEFULL TILE18' - 0 1/4"8' - 8"FULL TILEFULL TILE WC-01 CPT-10 1 A-510 Sim 9 A-510 Sim 6 A-510 Sim 7 A-510 Sim PLAN ELEV DUPLEX OUTLET QUADPLEX OUTLET GFCI OUTLET CAT6, RJ45 INTERNET OUTLET TELEPHONE OUTLET WALL MOUNTED WIRELESS THERMOSTAT POWER OUTLET WITH USB PORTS CATV OUTLET ELECTRICAL SWITCH FLOOR OUTLET POWER AND SIGNAL LEGEND: POWER SUPPLY CEILING FIXTURE LEGEND: 6" RECESSED CAN DOWNLIGHT DECORATIVE FLUSH MOUNT LIGHT PENDENT TYPE SPRINKLERS SMOKE DETECTOR EXHAUST FAN / GRILLE LINEAR SURFACE MOUNTED CONTINUOUS LED SYSTEM W/ FIXED MOUNTING CLIPS & FROSTED LENS / 3 WATTS PER FOOT, MLV/FWD ELECTRICAL OUTLET HEIGHTS (U.N.O) TYPICAL OUTLET - 15" A.F.F TYPICAL ACCESSIBLE WALL OUTLET - 18" A.F.F BATHROOM VANITY OUTLET - 42" A.F.F TYP. KITCHEN OUTLET - 42" A.F.F ADA KITCHEN OUTLET - 46" A.F.F ADA BATHROOM VANITY OUTLET - 44" A.F.F ELECTRICAL SWITCH HEIGHTS (U.N.O) SWITCH - 44" A.F.F THERMOSTAT REMOTE - 48" A.F.F MAX TO TOP OF SWITCH JUNCTION BOX DOOR BELL HARDWIRED TO DOORBELL LIGHT - MOUNT @ 46" A.F.F TO CENTER OF BUTTON (FOR COMMUNICATIONS FEATURES ROOMS ONLY) SD 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216UNIT PLAN - DOUBLEQUEEN STUDIO ADA-ELEC, DATA & FLOORFINISH PLAN A-421A FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 1/2" = 1'-0"1DOUBLE QUEEN STUDIO ADA ELECTRICAL & DATA PLAN Unit 512 1/2" = 1'-0"2DOUBLE QUEEN STUDIO ADA FLOOR & WALL FINISH PLAN Unit 512 15 10 12 8 9 11 13 16 14 3 0'1' 2'4' SCALE: 1/2" = 1'-0" KEYNOTES - UNIT PLANS 1 ALIGN 2 GENERAL CONTRACTOR TO COORDINATE W/ FURNITUREFABRICATOR WHERE NECESSARY TO PROVIDE PROPERBLOCKING IN WALL FOR ITEM KEYNOTED 3 NO FINISHES UNDER THE SHOWER PAN / TUB 4 NO FINISHES UNDER MILLWORK CABINETRY 5 TV AND MOUNT NOT TO PROJECT MORE THAN 4" FROMWALL 6 MOTORIZED BLINDS. PROVIDE JUNCTION BOX BEHINDVALENCE FOR POWER CONNECTION AND PERMANENTLYINSTALLED SWITCH ON WALL TO CONTROL BLINDS. 7 SWITCH CONTROLLING UNDER CABINET LIGHTING ATKITCHEN TO BE GANGED WITH LIGHTING AT ENTRY 8 SWITCH CONTROLLING GARBAGE DISPOSAL-REFER TOHADG FOR ACCESSIBLE ROOM REQ'S. 9 DEDICATED CIRCUIT FOR GARBAGE DISPOSAL 10 MASTER SWITCH 11 DEDICATED CIRCUIT FOR INDUCTION COOKTOP 12 DEDICATED CIRCUIT FOR DISHWASHER 13 DEDICATED CIRCUIT FOR REFRIGERATOR 14 ELECTRIC VANITY MIRROR - HARDWIRE FIXTURE TO WALL-CONTRACTOR TO VERIFY JBOX TYPE TO ENSURE PROPERINSTALLATION AND BACKING FOR ITEM KEYNOTED 15 DOORBELL AND DOORBELL ON/OFF SWITCH(COMMUNICATION FEATURES ROOMS ONLY)SIGNAGE ASREQ'D. 16 PLACE TV OUTLETS AND CONNECTIONS ON WALL OUTSIDEAREA OF BRACKET AND CONCEALED FROM VIEW BY TV 17 DEDICATED CIRCUIT FOR WASHER/DRYER. DIRECT VENTTO EXTERIOR FURNISHING SCHEDULE GUESTROOM FURNISHINGS GR-101 CHAIR - LOUNGE CHAIR IN STUIDOS GR-103 CHAIR - KITCHEN STOOL GR-105 SOFA - SLEEP BETWEEN ARMS GR-201 SCONCE - NIGHTSTAND GR-205 LAMP - FLOOR LAMP GR-206 LAMP - DOUBLE QUEEN READING LAMP GR-308 NIGHTSTAND - REGULAR GR-312 TABLE - NESTING GR-313 TABLE - ROUND SIDE TABLE GR-314 TABLE - PRODUCTIVITY TABLE (STUDIO) GR-322 CLOSET - ACCESSIBLE KING STUDIO SUITE GR-327 VANITY - ACCESSIBLE SUITES GR-328 BATH CADDY - ACCESSIBLE SUITES GR-400 STATIC DRAPARY PANELS GR-503 ART- ENTRY GR-506 MIRROR - GUESTROOM FULL LENGTH GR-507 MIRROR - ADA VANITY GR-800 KITCHENETTE - 1-BEDROOM GR-900 GUESTROOM REFRIGERATOR GR-901 GUESTROOM DISHWASHER GR-902 GUESTROOM COOKTOP - 2 BURNER GR-906GR-911 TELEVISION & TELEVISION MOUNT GR-907 CLOCK/RADIO GR-908 TELEPHONE - GUESTROOM GR-QM BED - QUEEN MOBILITY (GR-302, 306, 601,603) PLUMBING/MECHANICAL FIXTURES PF-01 TOILET - GUESTROOM PF-06 BATHTUB - 5' X 32" WITH SIDE LEDGE PF-07 LAVATORY - UNDERMOUNT, 20" X 14" PF-12 SHOWER HEAD - HAND HELD ON SLIDE BAR PF-13 SHOWER/TUB VALVE & CONTROL PF-14 BATHTUB FILL FAUCET PF-15 FAUCET - LAVATORY PF-41 FAUCET - KITCHENETTE PF-42 SINK - ADA KITCHENETTE TOILET ACCESSORIES HD-02 DUAL TOILET PAPER HOLDER- ADA HD-04 WALL-MOUNTED ROBE HOOK HD-04.1 TOWEL BAR HD-08 18" GRAB BAR HD-09 24" GRAB BAR HD-10 42" GRAB BAR AT ADA BATHTUB HD-11 36" GRAB BAR HD-11.1 42" GRAB BAR HD-14.1 ROLL-IN SHOWER SEAT HD-16 BULK AMENITY DISPENSER ATSHOWERS/TUBS HD-18.1 SOAP SHELF HD-20 12" GRAB BAR HD-21 BULK AMENITY DISPENSER AT LAVATORIES EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV Revision Schedule Number Description Date TV WC-01 RB-015' - 0"4' - 3 1/4" WD-01 WC-01 4' - 2"WD-01 SS-01 RB-01 5' - 5 1/4" WC-01 5' - 1"EQ EQ GR-403 6 D-G02A GR-900 GR-901 PL-02 PT-03 SF-01 W-G RB-01 16 A-510 Sim GR-403GR-403 4' - 11"EQ EQ RB-01RB-01 WC-01WC-01 RB-01 PLANELEV DUPLEX OUTLET QUADPLEX OUTLET GFCI OUTLET CAT6, RJ45 INTERNET OUTLET TELEPHONE OUTLET WALL MOUNTED WIRELESS THERMOSTAT POWER OUTLET WITH USB PORTS CATV OUTLET ELECTRICAL SWITCH FLOOR OUTLET POWER AND SIGNAL LEGEND: POWER SUPPLY JUNCTION BOX DOOR BELL HARDWIRED TO DOORBELL LIGHT - MOUNT @ 46" A.F.F TO CENTER OF BUTTON (FOR COMMUNICATIONS FEATURES ROOMS ONLY) CEILING FIXTURE LEGEND: 6" RECESSED CAN DOWNLIGHT DECORATIVE FLUSH MOUNT LIGHT PENDENT TYPE SPRINKLERS SMOKE DETECTOR EXHAUST FAN / GRILLE LINEAR SURFACE MOUNTED CONTINUOUS LED SYSTEM W/ FIXED MOUNTING CLIPS & FROSTED LENS / 3 WATTS PER FOOT, MLV/FWD ELECTRICAL OUTLET HEIGHTS (U.N.O) TYPICAL OUTLET - 15" A.F.F TYPICAL ACCESSIBLE WALL OUTLET - 18" A.F.F BATHROOM VANITY OUTLET - 42" A.F.F TYP. KITCHEN OUTLET - 42" A.F.F ADA KITCHEN OUTLET - 46" A.F.F ADA BATHROOM VANITY OUTLET - 44" A.F.F ELECTRICAL SWITCH HEIGHTS (U.N.O) SWITCH - 44" A.F.F THERMOSTAT REMOTE - 48" A.F.F MAX TO TOP OF SWITCH SD 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216UNIT INT. ELEVATION -DOUBLE QUEEN STUDIOADA MOBILITY A-421B FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 FFL FFL 1/2" = 1'-0" Reference: 1 / A-421 1DOUBLE QUEEN STUDIO ADA ELEVATION A Unit 512 1/2" = 1'-0" Reference: 1 / A-421 2DOUBLE QUEEN STUDIO ADA ELEVATION B Unit 512 1/2" = 1'-0" Reference: 1 / A-421 3DOUBLE QUEEN STUDIO ADA ELEVATION C Unit 512 1/2" = 1'-0" Reference: 1 / A-421 4DOUBLE QUEEN STUDIO ADA ELEVATION D Unit 512 FURNISHING SCHEDULE GUESTROOM FURNISHINGS GR-101 CHAIR - LOUNGE CHAIR IN STUIDOS GR-105 SOFA - SLEEP BETWEEN ARMS GR-201 SCONCE - NIGHTSTAND GR-203 PENDANT LIGHT - PRODUCTIVITY TABLE GR-205 LAMP - FLOOR LAMP GR-206 LAMP - DOUBLE QUEEN READING LAMP GR-307 NIGHTSTAND - SMALL GR-308 NIGHTSTAND - REGULAR GR-312 TABLE - NESTING GR-313 TABLE - ROUND SIDE TABLE GR-314 TABLE - PRODUCTIVITY TABLE (STUDIO) GR-322 CLOSET - ACCESSIBLE KING STUDIO SUITE GR-326 VANITY - STUDIO AND 1-BEDROOM SUITES GR-327 VANITY - ACCESSIBLE SUITES GR-328 BATH CADDY - ACCESSIBLE SUITES GR-400 STATIC DRAPARY PANELS GR-403 ROLLER SHADE - GUESTROOMS (MANUAL,SHEER/BLACK-OUT, 8' W) GR-412 VALENCE FOR 8' WINDOW GR-503 ART- ENTRY GR-506 MIRROR - GUESTROOM FULL LENGTH GR-507 MIRROR - ADA VANITY GR-800 KITCHENETTE - 1-BEDROOM GR-900 GUESTROOM REFRIGERATOR FURNISHING SCHEDULE GR-901 GUESTROOM DISHWASHER GR-902 GUESTROOM COOKTOP - 2 BURNER GR-904 GARBAGE DISPOSAL 1/3HP GR-905 MICROWAVE- WITH RECIRCULATING HOOD GR-906GR-911 TELEVISION & TELEVISION MOUNT GR-907 CLOCK/RADIO GR-908 TELEPHONE - GUESTROOM GR-912 RECIRCULATING HOOD GR-QM BED - QUEEN MOBILITY (GR-302, 306, 601, 603) GR-QS BED - QUEEN (GR-302, 305, 601) OWNER SPECIFIED - OWNER FURNISHED OP-706 FIRE EXTINGUISHER CABINET PLUMBING/MECHANICAL FIXTURES PF-01 TOILET - GUESTROOM PF-03 SHOWER BASE - 60" X 36" WITH LINEAR DRAIN PF-06 BATHTUB - 5' X 32" WITH SIDE LEDGE PF-07 LAVATORY - UNDERMOUNT, 20" X 14" PF-10 SHOWER HEAD - HIGH PF-11 SHOWER HEAD - 2 IN 1 PF-12 SHOWER HEAD - HAND HELD ON SLIDE BAR PF-13 SHOWER/TUB VALVE & CONTROL FURNISHING SCHEDULE PF-14 BATHTUB FILL FAUCET PF-15 FAUCET - LAVATORY PF-40 SINK - KITCHENETTE PF-41 FAUCET - KITCHENETTE PF-42 SINK - ADA KITCHENETTE TOILET ACCESSORIES HD-02 DUAL TOILET PAPER HOLDER- ADA HD-04 WALL-MOUNTED ROBE HOOK HD-04.1 TOWEL BAR HD-05 CURVED CURTAIN ROD AND SHOWER CURTAIN HD-05.2 SLIDING SHOWER DOOR HD-08 18" GRAB BAR HD-09 24" GRAB BAR HD-10 42" GRAB BAR AT ADA BATHTUB HD-11 36" GRAB BAR HD-11.1 42" GRAB BAR HD-14.1 ROLL-IN SHOWER SEAT HD-16 BULK AMENITY DISPENSER AT SHOWERS/TUBS HD-18.1 SOAP SHELF HD-20 12" GRAB BAR HD-21 BULK AMENITY DISPENSER AT LAVATORIES KEYNOTES - UNIT PLANS 1 ALIGN 2 GENERAL CONTRACTOR TO COORDINATE W/ FURNITUREFABRICATOR WHERE NECESSARY TO PROVIDE PROPERBLOCKING IN WALL FOR ITEM KEYNOTED 3 NO FINISHES UNDER THE SHOWER PAN / TUB 4 NO FINISHES UNDER MILLWORK CABINETRY 5 TV AND MOUNT NOT TO PROJECT MORE THAN 4" FROMWALL 6 MOTORIZED BLINDS. PROVIDE JUNCTION BOX BEHINDVALENCE FOR POWER CONNECTION AND PERMANENTLYINSTALLED SWITCH ON WALL TO CONTROL BLINDS. 7 SWITCH CONTROLLING UNDER CABINET LIGHTING ATKITCHEN TO BE GANGED WITH LIGHTING AT ENTRY 8 SWITCH CONTROLLING GARBAGE DISPOSAL-REFER TOHADG FOR ACCESSIBLE ROOM REQ'S. 9 DEDICATED CIRCUIT FOR GARBAGE DISPOSAL 10 MASTER SWITCH 11 DEDICATED CIRCUIT FOR INDUCTION COOKTOP 12 DEDICATED CIRCUIT FOR DISHWASHER 13 DEDICATED CIRCUIT FOR REFRIGERATOR 14 ELECTRIC VANITY MIRROR - HARDWIRE FIXTURE TO WALL-CONTRACTOR TO VERIFY JBOX TYPE TO ENSURE PROPERINSTALLATION AND BACKING FOR ITEM KEYNOTED 15 DOORBELL AND DOORBELL ON/OFF SWITCH(COMMUNICATION FEATURES ROOMS ONLY)SIGNAGE ASREQ'D. 16 PLACE TV OUTLETS AND CONNECTIONS ON WALL OUTSIDEAREA OF BRACKET AND CONCEALED FROM VIEW BY TV 17 DEDICATED CIRCUIT FOR WASHER/DRYER. DIRECT VENTTO EXTERIOR EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV Revision Schedule Number Description Date MMAATVSD TV CL-B27' - 6" CL-B27' - 6" CL-B8' - 0" GR-400 GR-4001' - 5"1' - 5"3' - 8 1/4"5' - 7 1/4"2' - 4"5' - 10 1/2"4' - 0"OF TABLE 1 1 1 1 1 1 1 1 A-422B2 1 4 3 P3.1 D-G03 D-G01 D-G02 W-GXE3 D-G03 18' - 9 1/4"9' - 9 1/4"9' - 1 1/4" 1' - 10"2' - 2 3/4"2' - 1" 6' - 6 1/2"12' - 3 1/2" 11' - 9"0' - 6 1/2" 7' - 1 1/4" GR-900 GR-902 GR-508 GR-901 GR-308 GR-201 GR-908GR-906GR-911 GR-101 GR-205 GR-313 GR-312 GR-105GR-QS GR-QS GR-206 GR-206 GR-326 GR-907 GR-321 GR-506 GR-503 PLAN ELEV DUPLEX OUTLET QUADPLEX OUTLET GFCI OUTLET CAT6, RJ45 INTERNET OUTLET TELEPHONE OUTLET WALL MOUNTED WIRELESS THERMOSTAT POWER OUTLET WITH USB PORTS CATV OUTLET ELECTRICAL SWITCH FLOOR OUTLET POWER AND SIGNAL LEGEND: POWER SUPPLY CEILING FIXTURE LEGEND: 6" RECESSED CAN DOWNLIGHT DECORATIVE FLUSH MOUNT LIGHT PENDENT TYPE SPRINKLERS SMOKE DETECTOR EXHAUST FAN / GRILLE LINEAR SURFACE MOUNTED CONTINUOUS LED SYSTEM W/ FIXED MOUNTING CLIPS & FROSTED LENS / 3 WATTS PER FOOT, MLV/FWD ELECTRICAL OUTLET HEIGHTS (U.N.O) TYPICAL OUTLET - 15" A.F.F TYPICAL ACCESSIBLE WALL OUTLET - 18" A.F.F BATHROOM VANITY OUTLET - 42" A.F.F TYP. KITCHEN OUTLET - 42" A.F.F ADA KITCHEN OUTLET - 46" A.F.F ADA BATHROOM VANITY OUTLET - 44" A.F.F ELECTRICAL SWITCH HEIGHTS (U.N.O) SWITCH - 44" A.F.F THERMOSTAT REMOTE - 48" A.F.F MAX TO TOP OF SWITCH JUNCTION BOX DOOR BELL HARDWIRED TO DOORBELL LIGHT - MOUNT @ 46" A.F.F TO CENTER OF BUTTON (FOR COMMUNICATIONS FEATURES ROOMS ONLY) SD 1/2" = 1'-0" Reference: 1 / A-102 1 DOUBLE QUEEN STUDIO ENLARGED UNIT CONSTRUCTIONPLAN Units 212, 312, 412 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216UNIT PLAN - DOUBLEQUEEN STUDIOENLARGED A-422 FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 1/2" = 1'-0"2DOUBLE QUEEN STUDIO ENLARGED UNIT RCP Units 212, 312, 412 0'1' 2'4' SCALE: 1/2" = 1'-0" 2 5 22 2 2 KEYNOTES - UNIT PLANS 1 ALIGN 2 GENERAL CONTRACTOR TO COORDINATE W/ FURNITUREFABRICATOR WHERE NECESSARY TO PROVIDE PROPERBLOCKING IN WALL FOR ITEM KEYNOTED 3 NO FINISHES UNDER THE SHOWER PAN / TUB 4 NO FINISHES UNDER MILLWORK CABINETRY 5 TV AND MOUNT NOT TO PROJECT MORE THAN 4" FROMWALL 6 MOTORIZED BLINDS. PROVIDE JUNCTION BOX BEHINDVALENCE FOR POWER CONNECTION AND PERMANENTLYINSTALLED SWITCH ON WALL TO CONTROL BLINDS. 7 SWITCH CONTROLLING UNDER CABINET LIGHTING ATKITCHEN TO BE GANGED WITH LIGHTING AT ENTRY 8 SWITCH CONTROLLING GARBAGE DISPOSAL-REFER TOHADG FOR ACCESSIBLE ROOM REQ'S. 9 DEDICATED CIRCUIT FOR GARBAGE DISPOSAL 10 MASTER SWITCH 11 DEDICATED CIRCUIT FOR INDUCTION COOKTOP 12 DEDICATED CIRCUIT FOR DISHWASHER 13 DEDICATED CIRCUIT FOR REFRIGERATOR 14 ELECTRIC VANITY MIRROR - HARDWIRE FIXTURE TO WALL-CONTRACTOR TO VERIFY JBOX TYPE TO ENSURE PROPERINSTALLATION AND BACKING FOR ITEM KEYNOTED 15 DOORBELL AND DOORBELL ON/OFF SWITCH(COMMUNICATION FEATURES ROOMS ONLY)SIGNAGE ASREQ'D. 16 PLACE TV OUTLETS AND CONNECTIONS ON WALL OUTSIDEAREA OF BRACKET AND CONCEALED FROM VIEW BY TV 17 DEDICATED CIRCUIT FOR WASHER/DRYER. DIRECT VENTTO EXTERIOR FURNISHING SCHEDULE GUESTROOM FURNISHINGS GR-101 CHAIR - LOUNGE CHAIR IN STUIDOS GR-103 CHAIR - KITCHEN STOOL GR-105 SOFA - SLEEP BETWEEN ARMS GR-201 SCONCE - NIGHTSTAND GR-203 PENDANT LIGHT - PRODUCTIVITY TABLE GR-205 LAMP - FLOOR LAMP GR-206 LAMP - DOUBLE QUEEN READING LAMP GR-308 NIGHTSTAND - REGULAR GR-312 TABLE - NESTING GR-313 TABLE - ROUND SIDE TABLE GR-314 TABLE - PRODUCTIVITY TABLE (STUDIO) GR-318 DRESSER - HIGHBOY GR-321 CLOSET - KING STUDIO SUITE GR-326 VANITY - STUDIO AND 1-BEDROOM SUITES GR-400 STATIC DRAPARY PANELS GR-403 ROLLER SHADE - GUESTROOMS (MANUAL,SHEER/BLACK-OUT, 8' W) GR-412 VALENCE FOR 8' WINDOW GR-503 ART- ENTRY GR-505 WALL HOOK GR-506 MIRROR - GUESTROOM FULL LENGTH GR-508 MIRROR - GUESTROOM VANITY GR-800 KITCHENETTE - 1-BEDROOM GR-900 GUESTROOM REFRIGERATOR GR-901 GUESTROOM DISHWASHER GR-902 GUESTROOM COOKTOP - 2 BURNER GR-904 GARBAGE DISPOSAL 1/3HP GR-905 MICROWAVE- WITH RECIRCULATING HOOD GR-906GR-911 TELEVISION & TELEVISION MOUNT GR-907 CLOCK/RADIO GR-908 TELEPHONE - GUESTROOM GR-QS BED - QUEEN (GR-302, 305, 601) PLUMBING/MECHANICAL FIXTURES PF-01 TOILET - GUESTROOM PF-03 SHOWER BASE - 60" X 36" WITH LINEARDRAIN PF-07 LAVATORY - UNDERMOUNT, 20" X 14" PF-11 SHOWER HEAD - 2 IN 1 PF-13 SHOWER/TUB VALVE & CONTROL PF-15 FAUCET - LAVATORY PF-40 SINK - KITCHENETTE PF-41 FAUCET - KITCHENETTE TOILET ACCESSORIES HD-01 DUAL TOILET PAPER HOLDER HD-04 WALL-MOUNTED ROBE HOOK HD-04.1 TOWEL BAR HD-05.2 SLIDING SHOWER DOOR HD-08 18" GRAB BAR HD-16 BULK AMENITY DISPENSER ATSHOWERS/TUBS HD-18 FOOT LEDGE FOR SHOWER HD-18.1 SOAP SHELF HD-21 BULK AMENITY DISPENSER AT LAVATORIES EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV Revision Schedule Number Description Date TVTV A-422B2 1 4 3 A-454 WC-01 WC-01 WC-01 WC-01 WC-01 SF-01 FULL TILE FULL TILE18' - 9 1/4"8' - 7"FULL TILEFULL TILE RES-01 CPT-01 CT-01 CPT-10 9 A-510 Sim 1 A-510 Sim 6 A-510 Sim 7 A-510 Sim PLAN ELEV DUPLEX OUTLET QUADPLEX OUTLET GFCI OUTLET CAT6, RJ45 INTERNET OUTLET TELEPHONE OUTLET WALL MOUNTED WIRELESS THERMOSTAT POWER OUTLET WITH USB PORTS CATV OUTLET ELECTRICAL SWITCH FLOOR OUTLET POWER AND SIGNAL LEGEND: POWER SUPPLY CEILING FIXTURE LEGEND: 6" RECESSED CAN DOWNLIGHT DECORATIVE FLUSH MOUNT LIGHT PENDENT TYPE SPRINKLERS SMOKE DETECTOR EXHAUST FAN / GRILLE LINEAR SURFACE MOUNTED CONTINUOUS LED SYSTEM W/ FIXED MOUNTING CLIPS & FROSTED LENS / 3 WATTS PER FOOT, MLV/FWD ELECTRICAL OUTLET HEIGHTS (U.N.O) TYPICAL OUTLET - 15" A.F.F TYPICAL ACCESSIBLE WALL OUTLET - 18" A.F.F BATHROOM VANITY OUTLET - 42" A.F.F TYP. KITCHEN OUTLET - 42" A.F.F ADA KITCHEN OUTLET - 46" A.F.F ADA BATHROOM VANITY OUTLET - 44" A.F.F ELECTRICAL SWITCH HEIGHTS (U.N.O) SWITCH - 44" A.F.F THERMOSTAT REMOTE - 48" A.F.F MAX TO TOP OF SWITCH JUNCTION BOX DOOR BELL HARDWIRED TO DOORBELL LIGHT - MOUNT @ 46" A.F.F TO CENTER OF BUTTON (FOR COMMUNICATIONS FEATURES ROOMS ONLY) SD 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216UNIT PLAN - DOUBLEQUEEN STUDIOENLARGED - ELEC,DATA & FLOOR FINISHPLANA-422A FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 0'1' 2'4' SCALE: 1/2" = 1'-0" 1/2" = 1'-0"1 DOUBLE QUEEN STUDIO ENLARGED UNIT ELECTRICAL & DATAPLAN Units 212, 312, 412 1/2" = 1'-0"2 DOUBLE QUEEN STUDIO ENLARGED FLOOR AND WALL FINISHPLAN Units 212, 312, 412 15 10 12 8 9 11 13 14 16 3 KEYNOTES - UNIT PLANS 1 ALIGN 2 GENERAL CONTRACTOR TO COORDINATE W/ FURNITUREFABRICATOR WHERE NECESSARY TO PROVIDE PROPERBLOCKING IN WALL FOR ITEM KEYNOTED 3 NO FINISHES UNDER THE SHOWER PAN / TUB 4 NO FINISHES UNDER MILLWORK CABINETRY 5 TV AND MOUNT NOT TO PROJECT MORE THAN 4" FROMWALL 6 MOTORIZED BLINDS. PROVIDE JUNCTION BOX BEHINDVALENCE FOR POWER CONNECTION AND PERMANENTLYINSTALLED SWITCH ON WALL TO CONTROL BLINDS. 7 SWITCH CONTROLLING UNDER CABINET LIGHTING ATKITCHEN TO BE GANGED WITH LIGHTING AT ENTRY 8 SWITCH CONTROLLING GARBAGE DISPOSAL-REFER TOHADG FOR ACCESSIBLE ROOM REQ'S. 9 DEDICATED CIRCUIT FOR GARBAGE DISPOSAL 10 MASTER SWITCH 11 DEDICATED CIRCUIT FOR INDUCTION COOKTOP 12 DEDICATED CIRCUIT FOR DISHWASHER 13 DEDICATED CIRCUIT FOR REFRIGERATOR 14 ELECTRIC VANITY MIRROR - HARDWIRE FIXTURE TO WALL-CONTRACTOR TO VERIFY JBOX TYPE TO ENSURE PROPERINSTALLATION AND BACKING FOR ITEM KEYNOTED 15 DOORBELL AND DOORBELL ON/OFF SWITCH(COMMUNICATION FEATURES ROOMS ONLY)SIGNAGE ASREQ'D. 16 PLACE TV OUTLETS AND CONNECTIONS ON WALL OUTSIDEAREA OF BRACKET AND CONCEALED FROM VIEW BY TV 17 DEDICATED CIRCUIT FOR WASHER/DRYER. DIRECT VENTTO EXTERIOR FURNISHING SCHEDULE GUESTROOM FURNISHINGS GR-101 CHAIR - LOUNGE CHAIR IN STUIDOS GR-103 CHAIR - KITCHEN STOOL GR-105 SOFA - SLEEP BETWEEN ARMS GR-201 SCONCE - NIGHTSTAND GR-205 LAMP - FLOOR LAMP GR-206 LAMP - DOUBLE QUEEN READING LAMP GR-308 NIGHTSTAND - REGULAR GR-312 TABLE - NESTING GR-313 TABLE - ROUND SIDE TABLE GR-314 TABLE - PRODUCTIVITY TABLE (STUDIO) GR-318 DRESSER - HIGHBOY GR-321 CLOSET - KING STUDIO SUITE GR-326 VANITY - STUDIO AND 1-BEDROOM SUITES GR-400 STATIC DRAPARY PANELS GR-503 ART- ENTRY GR-506 MIRROR - GUESTROOM FULL LENGTH GR-508 MIRROR - GUESTROOM VANITY GR-800 KITCHENETTE - 1-BEDROOM GR-900 GUESTROOM REFRIGERATOR GR-901 GUESTROOM DISHWASHER GR-902 GUESTROOM COOKTOP - 2 BURNER GR-904 GARBAGE DISPOSAL 1/3HP GR-906GR-911 TELEVISION & TELEVISION MOUNT GR-907 CLOCK/RADIO GR-908 TELEPHONE - GUESTROOM GR-QS BED - QUEEN (GR-302, 305, 601) PLUMBING/MECHANICAL FIXTURES PF-01 TOILET - GUESTROOM PF-03 SHOWER BASE - 60" X 36" WITH LINEARDRAIN PF-07 LAVATORY - UNDERMOUNT, 20" X 14" PF-11 SHOWER HEAD - 2 IN 1 PF-13 SHOWER/TUB VALVE & CONTROL PF-15 FAUCET - LAVATORY PF-40 SINK - KITCHENETTE PF-41 FAUCET - KITCHENETTE TOILET ACCESSORIES HD-01 DUAL TOILET PAPER HOLDER HD-04.1 TOWEL BAR HD-05.2 SLIDING SHOWER DOOR HD-08 18" GRAB BAR HD-16 BULK AMENITY DISPENSER ATSHOWERS/TUBS HD-18 FOOT LEDGE FOR SHOWER HD-18.1 SOAP SHELF HD-21 BULK AMENITY DISPENSER AT LAVATORIES EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV Revision Schedule Number Description Date TV WC-01 RB-015' - 1"2' - 3 1/2" SS-01 WD-01 D-G01 GR-505 0' - 8" WD-01 RB-01 WC-01 WC-01 RB-01WC-01 RB-01 WD-01WD-01 4' - 2"5' - 5 1/4" GR-403 ? SF-01 RB-01 W-G GR-412 PT-03 16 A-510 Sim WC-01WC-01 RB-01 RB-01 3' - 3 3/4"5' - 2"1' - 10 1/2" D-G03 PLANELEV DUPLEX OUTLET QUADPLEX OUTLET GFCI OUTLET CAT6, RJ45 INTERNET OUTLET TELEPHONE OUTLET WALL MOUNTED WIRELESS THERMOSTAT POWER OUTLET WITH USB PORTS CATV OUTLET ELECTRICAL SWITCH FLOOR OUTLET POWER AND SIGNAL LEGEND: POWER SUPPLY JUNCTION BOX DOOR BELL HARDWIRED TO DOORBELL LIGHT - MOUNT @ 46" A.F.F TO CENTER OF BUTTON (FOR COMMUNICATIONS FEATURES ROOMS ONLY) CEILING FIXTURE LEGEND: 6" RECESSED CAN DOWNLIGHT DECORATIVE FLUSH MOUNT LIGHT PENDENT TYPE SPRINKLERS SMOKE DETECTOR EXHAUST FAN / GRILLE LINEAR SURFACE MOUNTED CONTINUOUS LED SYSTEM W/ FIXED MOUNTING CLIPS & FROSTED LENS / 3 WATTS PER FOOT, MLV/FWD ELECTRICAL OUTLET HEIGHTS (U.N.O) TYPICAL OUTLET - 15" A.F.F TYPICAL ACCESSIBLE WALL OUTLET - 18" A.F.F BATHROOM VANITY OUTLET - 42" A.F.F TYP. KITCHEN OUTLET - 42" A.F.F ADA KITCHEN OUTLET - 46" A.F.F ADA BATHROOM VANITY OUTLET - 44" A.F.F ELECTRICAL SWITCH HEIGHTS (U.N.O) SWITCH - 44" A.F.F THERMOSTAT REMOTE - 48" A.F.F MAX TO TOP OF SWITCH SD 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216UNIT INT. ELEVATION -DOUBLE QUEEN STUDIOENLARGED A-422B FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 FFL FFL 1/2" = 1'-0" Reference: 1 / A-422 1DOUBLE QUEEN STUDIO ENLARGED ELEVATION A Units 212, 312, 412 1/2" = 1'-0" Reference: 1 / A-422 2DOUBLE QUEEN STUDIO ENLARGED ELEVATION B Units 212, 312, 412 1/2" = 1'-0" Reference: 1 / A-422 3DOUBLE QUEEN STUDIO ENLARGED ELEVATION C Units 212, 312, 412 1/2" = 1'-0" Reference: 1 / A-422 4DOUBLE QUEEN STUDIO ENLARGED ELEVATION D Units 212, 312, 412 FURNISHING SCHEDULE GUESTROOM FURNISHINGS GR-101 CHAIR - LOUNGE CHAIR IN STUIDOS GR-103 CHAIR - KITCHEN STOOL GR-105 SOFA - SLEEP BETWEEN ARMS GR-201 SCONCE - NIGHTSTAND GR-203 PENDANT LIGHT - PRODUCTIVITY TABLE GR-205 LAMP - FLOOR LAMP GR-206 LAMP - DOUBLE QUEEN READING LAMP GR-307 NIGHTSTAND - SMALL GR-308 NIGHTSTAND - REGULAR GR-312 TABLE - NESTING GR-313 TABLE - ROUND SIDE TABLE GR-314 TABLE - PRODUCTIVITY TABLE (STUDIO) GR-318 DRESSER - HIGHBOY GR-321 CLOSET - KING STUDIO SUITE GR-326 VANITY - STUDIO AND 1-BEDROOM SUITES GR-400 STATIC DRAPARY PANELS GR-403 ROLLER SHADE - GUESTROOMS (MANUAL,SHEER/BLACK-OUT, 8' W) GR-412 VALENCE FOR 8' WINDOW GR-503 ART- ENTRY GR-504 ART- SLEEPING/LIVING GR-505 WALL HOOK GR-506 MIRROR - GUESTROOM FULL LENGTH GR-508 MIRROR - GUESTROOM VANITY FURNISHING SCHEDULE GR-800 KITCHENETTE - 1-BEDROOM GR-900 GUESTROOM REFRIGERATOR GR-901 GUESTROOM DISHWASHER GR-902 GUESTROOM COOKTOP - 2 BURNER GR-904 GARBAGE DISPOSAL 1/3HP GR-905 MICROWAVE- WITH RECIRCULATING HOOD GR-906GR-911 TELEVISION & TELEVISION MOUNT GR-907 CLOCK/RADIO GR-908 TELEPHONE - GUESTROOM GR-QS BED - QUEEN (GR-302, 305, 601) OWNER SPECIFIED - OWNER FURNISHED OP-706 FIRE EXTINGUISHER CABINET PLUMBING/MECHANICAL FIXTURES PF-01 TOILET - GUESTROOM PF-03 SHOWER BASE - 60" X 36" WITH LINEAR DRAIN PF-07 LAVATORY - UNDERMOUNT, 20" X 14" PF-11 SHOWER HEAD - 2 IN 1 PF-13 SHOWER/TUB VALVE & CONTROL PF-15 FAUCET - LAVATORY PF-40 SINK - KITCHENETTE PF-41 FAUCET - KITCHENETTE FURNISHING SCHEDULE TOILET ACCESSORIES HD-01 DUAL TOILET PAPER HOLDER HD-04 WALL-MOUNTED ROBE HOOK HD-04.1 TOWEL BAR HD-05.2 SLIDING SHOWER DOOR HD-08 18" GRAB BAR HD-16 BULK AMENITY DISPENSER AT SHOWERS/TUBS HD-18 FOOT LEDGE FOR SHOWER HD-18.1 SOAP SHELF HD-21 BULK AMENITY DISPENSER AT LAVATORIES KEYNOTES - UNIT PLANS 1 ALIGN 2 GENERAL CONTRACTOR TO COORDINATE W/ FURNITUREFABRICATOR WHERE NECESSARY TO PROVIDE PROPERBLOCKING IN WALL FOR ITEM KEYNOTED 3 NO FINISHES UNDER THE SHOWER PAN / TUB 4 NO FINISHES UNDER MILLWORK CABINETRY 5 TV AND MOUNT NOT TO PROJECT MORE THAN 4" FROMWALL 6 MOTORIZED BLINDS. PROVIDE JUNCTION BOX BEHINDVALENCE FOR POWER CONNECTION AND PERMANENTLYINSTALLED SWITCH ON WALL TO CONTROL BLINDS. 7 SWITCH CONTROLLING UNDER CABINET LIGHTING ATKITCHEN TO BE GANGED WITH LIGHTING AT ENTRY 8 SWITCH CONTROLLING GARBAGE DISPOSAL-REFER TOHADG FOR ACCESSIBLE ROOM REQ'S. 9 DEDICATED CIRCUIT FOR GARBAGE DISPOSAL 10 MASTER SWITCH 11 DEDICATED CIRCUIT FOR INDUCTION COOKTOP 12 DEDICATED CIRCUIT FOR DISHWASHER 13 DEDICATED CIRCUIT FOR REFRIGERATOR 14 ELECTRIC VANITY MIRROR - HARDWIRE FIXTURE TO WALL-CONTRACTOR TO VERIFY JBOX TYPE TO ENSURE PROPERINSTALLATION AND BACKING FOR ITEM KEYNOTED 15 DOORBELL AND DOORBELL ON/OFF SWITCH(COMMUNICATION FEATURES ROOMS ONLY)SIGNAGE ASREQ'D. 16 PLACE TV OUTLETS AND CONNECTIONS ON WALL OUTSIDEAREA OF BRACKET AND CONCEALED FROM VIEW BY TV 17 DEDICATED CIRCUIT FOR WASHER/DRYER. DIRECT VENTTO EXTERIOR EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV Revision Schedule Number Description Date TV A-4235 3 8 6 A-423 4 72' - 3"2' - 3"GR-325 GR-506 6' - 1"7' - 5"3' - 8 3/4"3' - 1"5' - 4"6' - 6 3/4"HD-01 GR-319 HD-08 HD-16 HD-18 14' - 3"HD-21 VERIFY SHOWER PAN DIMENSIONS 5' - 0" A-5103 A-5105Sim PF-01 PF-07 PF-15 PF-11 PF-03 ? HD-12 HD-18.1 4' - 0 1/2" TOP OF SOAP SHELFHD-18 HD-08 HD-04 WC-02 7' - 6"1' - 3"4 A-510 HD-16 CT-01.17' - 6"PF-03 PF-11 PF-13 1' - 5"1' - 5"3' - 3"3' - 6"EQEQ WC-01 WC-02 HD-08 GR-506 GR-325 SAFE GR-319 HD-21 3' - 5 1/2"2' - 9" CT-01.1 J 3 A-710 7' - 6"2' - 6"PF-11 PF-13 HD-04 PF-03 PF-01 CT-01.1 PF-15 1' - 9"2' - 0" HD-01 D-G03 PT-03WC-02 CT-01.1 EQEQ 7' - 6"PF-01 OPEN TO ROOM EQ EQ HD-16 HD-18 CT-01.1 WC-02WC-01 CT-01.17' - 6"GR-319 PF-03 2' - 9"3' - 0"3' - 6"1' - 5"0' - 5" CT-01.1 PT-03 D-G037' - 6"GR-325 GR-506 HD-21 WC-01 PF-15 SAFE GR-319 CT-01.1 WC-02 7' - 6"DOOR VANITY 1' - 2 1/2" WALL 3' - 0"0' - 2 1/2"1' - 0 1/2" CL-B27' - 6" CL-B27' - 6" WALL WALL PLAN ELEV DUPLEX OUTLET QUADPLEX OUTLET GFCI OUTLET CAT6, RJ45 INTERNET OUTLET TELEPHONE OUTLET WALL MOUNTED WIRELESS THERMOSTAT POWER OUTLET WITH USB PORTS CATV OUTLET ELECTRICAL SWITCH FLOOR OUTLET POWER AND SIGNAL LEGEND: POWER SUPPLY CEILING FIXTURE LEGEND: 6" RECESSED CAN DOWNLIGHT DECORATIVE FLUSH MOUNT LIGHT PENDENT TYPE SPRINKLERS SMOKE DETECTOR EXHAUST FAN / GRILLE LINEAR SURFACE MOUNTED CONTINUOUS LED SYSTEM W/ FIXED MOUNTING CLIPS & FROSTED LENS / 3 WATTS PER FOOT, MLV/FWD ELECTRICAL OUTLET HEIGHTS (U.N.O) TYPICAL OUTLET - 15" A.F.F TYPICAL ACCESSIBLE WALL OUTLET - 18" A.F.F BATHROOM VANITY OUTLET - 42" A.F.F TYP. KITCHEN OUTLET - 42" A.F.F ADA KITCHEN OUTLET - 46" A.F.F ADA BATHROOM VANITY OUTLET - 44" A.F.F ELECTRICAL SWITCH HEIGHTS (U.N.O) SWITCH - 44" A.F.F THERMOSTAT REMOTE - 48" A.F.F MAX TO TOP OF SWITCH JUNCTION BOX DOOR BELL HARDWIRED TO DOORBELL LIGHT - MOUNT @ 46" A.F.F TO CENTER OF BUTTON (FOR COMMUNICATIONS FEATURES ROOMS ONLY) SD 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216UNIT BATH -EFFICIENCY BATHPLANS AND INTERIORELEVATIONS A-423 FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 1/2" = 1'-0" Reference: 1 / A-411 1EFFICIENCY BATHROOM PLAN Units x05, 307, 407, 507, x08, x27-x29, x31, x33-x34 FFL 1/2" = 1'-0" Reference: 1 / A-423 3EFFICIENCY BATH ELEV. A Units x05, 307, 407, 507, x08, x27-x29, x31, x33-x34 1/2" = 1'-0" Reference: 1 / A-423 5EFFICIENCY BATH ELEV. B Units x05, 307, 407, 507, x08, x27-x29, x31, x33-x34 1/2" = 1'-0" Reference: 1 / A-423 6EFFICIENCY BATH ELEV. C Units x05, 307, 407, 507, x08, x27-x29, x31, x33-x34 1/2" = 1'-0" Reference: 1 / A-423 8EFFICIENCY BATH ELEV. D Units x05, 307, 407, 507, x08, x27-x29, x31, x33-x34 1/2" = 1'-0" Reference: 1 / A-423 4 EFFICIENCY BATH ELEV. A1 Units x05, 307, 407, 507, x08, x27-x29, x31, x33-x34 1/2" = 1'-0" Reference: 1 / A-423 7EFFICIENCY BATH ELEV. C1 Units x05, 307, 407, 507, x08, x27-x29, x31, x33-x34 KEYNOTES - UNIT BATHROOMS 1 WALL MOUNTED GRAB BARS REQUIREDCLEARANCES - 12" ABOVEAND 1-1/2" BELOW. REFER TO ACCESSIBILITYSTANDARDS & HADG 2 CURTAIN ROD 3 ACCESSIBLE SHOWER THRESHOLD. 1/2" MAXHEIGHT BEVELED 1:2 MAX. REFER TO HADG FORMORE INFORMATION 4 TOWEL/ROBE HOOK 5 DOUBLE TOILET PAPER HOLDER 6 ACCESSIBLE VANITY 7 ACCESSIBLE TUB/SHOWER SEAT. REFER TOACCESSIBILITY STANDARDS AND HADG FORREQUIREMENTS 8 CLEAR AREA OF SINK/VANITY MUST BEACCESSIBLE 9 ON/OFF - PRESSURE BALANCING VALVE ANDTEMPERATURE CONTROL. 10 SHOWER HEAD. "TWO-IN-ONE" SHOWER HEADWITH STATIONARY SHOWER HEAD PORTION ANDREMOVABLE HAND HELD SHOWER WAND 11 SHOWER DIVERTER VALVE 12 HAND SHOWER. HAND-HELD SHOWER UNITREQUIRED TO HAVE ON/OFF CONTROL WITHNON-POSITIVE SHUT OFF 13 VANITY LIGHTED MIRROR FIXTURE -- HARDWIREFIXTURE TO WALL- CONTRACTOR TO VERIFY JBOXTYPE TO ENSURE PROPER INSTALLATION ANDBACKING FOR ITEM KEYNOTED 14 GFCI OUTLETS 15 CORNER SOAP SHELF 17 BULK TOILETRY DISPENSERS 18 SHOWER ENCLOSURE W/ TEMPERED GLASS DOOR. 19 TOWEL BAR ON SHOWER SURROUND 20 FLOOR DRAIN LOCATION -- MAINTAIN ACCESSIBLECOMPLIANT SLOPES TO DRAIN 21 ADA ROLL-IN SHOWER BASE 22 FRAMING SUBCONTRACTOR TO PROVIDE 3/4" F.R.T.PLYWOOD BLOCKING TO RECEIVE ITEM INDICATED- EXTEND FULL LENGTH OF OBJECT 23 SHOWER SURROUND 24 TOILET 25 SHOWER BASE WITH LINEAR DRAIN 26 LAVATORY 27 FAUCET 28 GRAB BAR 29 BATHTUB 30 TUB FILL FAUCET 31 TOILET FLUSH HANDLE TO BE LOCATED ONAPPROACH SIDE 32 TOWEL BAR 33 IRON AND IRONING BOARD HANGER 34 CLOSET 35 BATH CADDY 36 SOAP DISH 37 FACIAL TISSUE COVER 38 SHAFT 39 WALL STOP 40 ALIGN 41 STATIONARY SHOWER HEAD. 40 24 22 13 22 24 31 38 13 22 22 26 34 19 18 5 5 24 10 22 34 33 2822 25 15 9 25 10 15 2822 4 17 36 37 27 17 17 22 23 40 2822 4 9 15 10 25 33 33 34 17 14 27 FFL FFL 0'1' 2'4' SCALE: 1/2" = 1'-0" 34 3322 23 25 23 40 17 18 27 1/2" = 1'-0" Reference: 2 / A-411 2EFFICIENCY BATHROOM RCP Units x05, 307, 407, 507, x08, x27-x29, x31, x33-x34 4 22 40 40 39 10.OBJECTS MOUNTED WITHIN THE CIRCULATION PATHIN ACCESSIBLE ROOMS BETWEEN 27" AND 80" AFFSHALL NOT PROTRUDE FURTHER THAN 4" FROM WALL- REFER TO HADM FOR FURTHER REQUIREMENTS. 9. OBJECTS MOUNTED WITHIN THE CIRCULATION PATHIN ACCESSIBLE ROOMS BETWEEN 27" AND 80" AFFSHALL NOT PROTRUDE FURTHER THAN 4" FROM WALL- REFER TO HADM FOR FURTHER REQUIREMENTS. 8. IN ACCESSIBLE ROOMS AT LEAST ONE OUTLET ANDDATA CONNECTION FOR USE BY GUESTS MUST BEMOUNTED BETWEEN 15" AND 48" AFF AND PROVIDE ACLEAR FLOOR AREA IN COMPLIANCE WITH... 7. ROOMS WITH COMMUNICATION DEVICES SHALL BEEQUIPPED WITH ACCESSIBLE DEVICES SUCH AS, BUTNOT LIMITED TO THE FOLLOWING: FIRE ALARMSTROBES, SMOKE DETECTOR STROBES AND DOORBUZZER STROBES, TELEPHONES WITH VOLUME... 6. ROOMS WITH COMMUNICATION DEVICES SHALL BEEQUIPPED WITH ACCESSIBLE DEVICES SUCH AS, BUTNOT LIMITED TO THE FOLLOWING: FIRE ALARMSTROBES, SMOKE DETECTOR STROBES AND DOORBUZZER STROBES, TELEPHONES WITH VOLUME... 5. CEILING MOUNTED LIGHT FIXTURE AND EXHAUST FANAT ALL GUESTROOM BATHS TO BE SWITCHEDSEPARATELY. 4. ELECTRICAL OUTLETS AT DESKS & NIGHTSTANDSARE TO BE COORDINATED WITH HOMEWOOD... 3. HEIGHT OF ALL SWITCHES, OUTLETS, ETC., TO MEETACCESSIBILITY STANDARDS FOR MAXIMUM ANDMINIMUM REACH RANGE. FEDERAL AND LOCALCODES APPLY AND THE MOST STRINGENT STANDARDPREVAILS. SWITCHES ON LAMPS MUST BE TOGGLE... 2. LIGHT SWITCH AND G.F.I. OUTLETS CAN BE MOUNTEDIN A COMMON BOX WITH COVER PLATE. COORDINAT... 1. AT WALLS BETWEEN ADJACENT ROOMS, ELECTRICALOUTLET OCATIONS, INCLUDING TV AND TELEPHONEOUTLETS, SHALL BE OFFSET 6" MIN. HORIZONTALLYFOR INSTALLATION. ELECTRICAL CORDS SHOULD BEHIDDEN FROM VIEW. BACK TO BACK OUTLETS ARE... GENERAL NOTES - UNITS EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV Revision Schedule Number Description Date ATV A-4246 5 4 CT-01D-G03A12' - 1 3/4"HD-16PF-10 HD-08 PF-12 HD-20 HD-05 PF-06 PF-01 HD-11 P1.1 P1.1 HD-04.1 HD-02 HD-11.1 GR-3281' - 3" VERIFY BATHTUB DIMENSIONS 5' - 0" 7' - 2" PF-07 GR-507 PF-15 4' - 9"HD-21 HD-04 HD-122' - 0"3' - 1"2' - 1" HD-10 HD-09HD-14.1HD-18.1 GR-327 WC-02 7' - 3 1/2"0' - 9 1/4" CT-01.1 HD-02 0' - 5 3/4" HD-08 HD-11.1 HD-05 PF-13 HD-10 PF-10 HD-08 PF-06 PF-14 PF-12 GR-507 GR-327 J PF-15 2' - 10"3' - 4"3' - 8"HD-11 PF-01 0' - 8"1' - 9"2' - 10"3' - 3"3' - 4"7' - 6"WC-02 0' - 8"CT-01.1 PF-10 PF-15 HD-09 HD-16 GR-507 HD-05 HD-04 HD-08 PF-06 GR-327HD-14.1 4 A-510 HD-12 3' - 8"WC-02 CT-01.1 PL-02PT-03 D-G03A HD-04 HD-20 HD-16 HD-04.1 HD-05 PF-06 HD-09 HD-14.14' - 0"3' - 11"GR-328 VANITY WALL WALL 0' - 1"1' - 8"1' - 8"EQ EQ3' - 1"CL-B27' - 6" PLAN ELEV DUPLEX OUTLET QUADPLEX OUTLET GFCI OUTLET CAT6, RJ45 INTERNET OUTLET TELEPHONE OUTLET WALL MOUNTED WIRELESS THERMOSTAT POWER OUTLET WITH USB PORTS CATV OUTLET ELECTRICAL SWITCH FLOOR OUTLET POWER AND SIGNAL LEGEND: POWER SUPPLY CEILING FIXTURE LEGEND: 6" RECESSED CAN DOWNLIGHT DECORATIVE FLUSH MOUNT LIGHT PENDENT TYPE SPRINKLERS SMOKE DETECTOR EXHAUST FAN / GRILLE LINEAR SURFACE MOUNTED CONTINUOUS LED SYSTEM W/ FIXED MOUNTING CLIPS & FROSTED LENS / 3 WATTS PER FOOT, MLV/FWD ELECTRICAL OUTLET HEIGHTS (U.N.O) TYPICAL OUTLET - 15" A.F.F TYPICAL ACCESSIBLE WALL OUTLET - 18" A.F.F BATHROOM VANITY OUTLET - 42" A.F.F TYP. KITCHEN OUTLET - 42" A.F.F ADA KITCHEN OUTLET - 46" A.F.F ADA BATHROOM VANITY OUTLET - 44" A.F.F ELECTRICAL SWITCH HEIGHTS (U.N.O) SWITCH - 44" A.F.F THERMOSTAT REMOTE - 48" A.F.F MAX TO TOP OF SWITCH JUNCTION BOX DOOR BELL HARDWIRED TO DOORBELL LIGHT - MOUNT @ 46" A.F.F TO CENTER OF BUTTON (FOR COMMUNICATIONS FEATURES ROOMS ONLY) SD VERIFY SHOWER PAN DIMENSIONS 5' - 0" 7' - 2" PF-13 HD-14 PF-12HD-16HD-11 HD-18.1 HD-09 HD-21 HD-04 PF-04PF-07 GR-507 PF-15 GR-327 PF-01 HD-11 P1.1 P1.1 HD-04.1 HD-12 HD-02 HD-11.1 GR-3281' - 3" PF-10 A-4249 8 7 10 D-G03A CT-012' - 0"2' - 1"4' - 9"HD-05.1EQ.EQ.6' - 9" MIN. TO BTM. OF SHOWER HEADPF-04 HD-18.1 HD-11 HD-09 PF-10 HD-16 HD-05.1 3' - 0"4' - 0"2' - 10"3' - 4"3' - 8"2' - 10"3' - 3"0' - 8"1' - 9"PF-01 HD-11 HD-11.1 HD-08 GR-507 HD-21 WC-02 CT-01.1 J GR-327 WC-02 CT-01.1 7' - 6"GR-328 HD-04.1 PF-01 HD-02 HD-11.1 HD-08 HD-11 4' - 0"GR-328 HD-04.1 HD-05.1 HD-16 HD-14 PF-12 PF-04 HD-04WC-02 CT-01.1 D-G03A PT-03PL-02 HD-14 HD-16 HD-11 PF-13 HD-04 PF-12 HD-05.1 PF-10 GR-507 HD-21 PF-15 PF-07 GR-327 CT-01.1 WC-02 PF-04 HD-18.1 A-710 2Sim 4 A-510 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216UNIT BATH-ACCESSIBLE BATHPLANS AND INTERIORELEVATIONS A-424 FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 FFL 1/2" = 1'-0" Reference: 1 / A-415 2ADA BATHTUB PLAN Units 138, 238, 303, 503, 512 1/2" = 1'-0" Reference: 2 / A-415A 6ADA BATHTUB ELEV. B Units 138, 238, 303, 503, 512 1/2" = 1'-0" Reference: 2 / A-415A 5ADA BATHTUB ELEV. A Units 138, 238, 303, 503, 512 1/2" = 1'-0" Reference: 2 / A-415A 4ADA BATHTUB ELEV. D Units 138, 238, 303, 503, 512 FFL 1/2" = 1'-0" Reference: 2 / A-412 3ADA BATH RCP Units 138, 238, 303, 503, 512 36 37 38 17 17 27 1 13 22 14 5 24 27 23 9 234 4 10 27 15 10 15 3 28 10 1322 2228 4 28 28 10 17 6 1322 22 4 KEYNOTES - UNIT BATHROOMS 1 WALL MOUNTED GRAB BARS REQUIREDCLEARANCES - 12" ABOVEAND 1-1/2" BELOW. REFER TO ACCESSIBILITYSTANDARDS & HADG 2 CURTAIN ROD 3 ACCESSIBLE SHOWER THRESHOLD. 1/2" MAXHEIGHT BEVELED 1:2 MAX. REFER TO HADG FORMORE INFORMATION 4 TOWEL/ROBE HOOK 5 DOUBLE TOILET PAPER HOLDER 6 ACCESSIBLE VANITY 7 ACCESSIBLE TUB/SHOWER SEAT. REFER TOACCESSIBILITY STANDARDS AND HADG FORREQUIREMENTS 8 CLEAR AREA OF SINK/VANITY MUST BEACCESSIBLE 9 ON/OFF - PRESSURE BALANCING VALVE ANDTEMPERATURE CONTROL. 10 SHOWER HEAD. "TWO-IN-ONE" SHOWER HEADWITH STATIONARY SHOWER HEAD PORTION ANDREMOVABLE HAND HELD SHOWER WAND 11 SHOWER DIVERTER VALVE 12 HAND SHOWER. HAND-HELD SHOWER UNITREQUIRED TO HAVE ON/OFF CONTROL WITHNON-POSITIVE SHUT OFF 13 VANITY LIGHTED MIRROR FIXTURE -- HARDWIREFIXTURE TO WALL- CONTRACTOR TO VERIFY JBOXTYPE TO ENSURE PROPER INSTALLATION ANDBACKING FOR ITEM KEYNOTED 14 GFCI OUTLETS 15 CORNER SOAP SHELF 17 BULK TOILETRY DISPENSERS 18 SHOWER ENCLOSURE W/ TEMPERED GLASS DOOR. 19 TOWEL BAR ON SHOWER SURROUND 20 FLOOR DRAIN LOCATION -- MAINTAIN ACCESSIBLECOMPLIANT SLOPES TO DRAIN 21 ADA ROLL-IN SHOWER BASE 22 FRAMING SUBCONTRACTOR TO PROVIDE 3/4" F.R.T.PLYWOOD BLOCKING TO RECEIVE ITEM INDICATED- EXTEND FULL LENGTH OF OBJECT 23 SHOWER SURROUND 24 TOILET 25 SHOWER BASE WITH LINEAR DRAIN 26 LAVATORY 27 FAUCET 28 GRAB BAR 29 BATHTUB 30 TUB FILL FAUCET 31 TOILET FLUSH HANDLE TO BE LOCATED ONAPPROACH SIDE 32 TOWEL BAR 33 IRON AND IRONING BOARD HANGER 34 CLOSET 35 BATH CADDY 36 SOAP DISH 37 FACIAL TISSUE COVER 38 SHAFT 39 WALL STOP 40 ALIGN 41 STATIONARY SHOWER HEAD. 10.OBJECTS MOUNTED WITHIN THE CIRCULATION PATHIN ACCESSIBLE ROOMS BETWEEN 27" AND 80" AFFSHALL NOT PROTRUDE FURTHER THAN 4" FROM WALL- REFER TO HADM FOR FURTHER REQUIREMENTS. 9. OBJECTS MOUNTED WITHIN THE CIRCULATION PATHIN ACCESSIBLE ROOMS BETWEEN 27" AND 80" AFFSHALL NOT PROTRUDE FURTHER THAN 4" FROM WALL- REFER TO HADM FOR FURTHER REQUIREMENTS. 8. IN ACCESSIBLE ROOMS AT LEAST ONE OUTLET ANDDATA CONNECTION FOR USE BY GUESTS MUST BEMOUNTED BETWEEN 15" AND 48" AFF AND PROVIDE ACLEAR FLOOR AREA IN COMPLIANCE WITH... 7. ROOMS WITH COMMUNICATION DEVICES SHALL BEEQUIPPED WITH ACCESSIBLE DEVICES SUCH AS, BUTNOT LIMITED TO THE FOLLOWING: FIRE ALARMSTROBES, SMOKE DETECTOR STROBES AND DOORBUZZER STROBES, TELEPHONES WITH VOLUME... 6. ROOMS WITH COMMUNICATION DEVICES SHALL BEEQUIPPED WITH ACCESSIBLE DEVICES SUCH AS, BUTNOT LIMITED TO THE FOLLOWING: FIRE ALARMSTROBES, SMOKE DETECTOR STROBES AND DOORBUZZER STROBES, TELEPHONES WITH VOLUME... 5. CEILING MOUNTED LIGHT FIXTURE AND EXHAUST FANAT ALL GUESTROOM BATHS TO BE SWITCHEDSEPARATELY. 4. ELECTRICAL OUTLETS AT DESKS & NIGHTSTANDSARE TO BE COORDINATED WITH HOMEWOOD... 3. HEIGHT OF ALL SWITCHES, OUTLETS, ETC., TO MEETACCESSIBILITY STANDARDS FOR MAXIMUM ANDMINIMUM REACH RANGE. FEDERAL AND LOCALCODES APPLY AND THE MOST STRINGENT STANDARDPREVAILS. SWITCHES ON LAMPS MUST BE TOGGLE... 2. LIGHT SWITCH AND G.F.I. OUTLETS CAN BE MOUNTEDIN A COMMON BOX WITH COVER PLATE. COORDINAT... 1. AT WALLS BETWEEN ADJACENT ROOMS, ELECTRICALOUTLET OCATIONS, INCLUDING TV AND TELEPHONEOUTLETS, SHALL BE OFFSET 6" MIN. HORIZONTALLYFOR INSTALLATION. ELECTRICAL CORDS SHOULD BEHIDDEN FROM VIEW. BACK TO BACK OUTLETS ARE... GENERAL NOTES - UNITS 1/2" = 1'-0" Reference: 1 / A-412 1ADA ROLL-IN SHOWER PLAN Units 338, 403 38 22 27 36 37 5 24 31 15 4 32 9 26 17 28 13 35 4 221 28221 20 5 24 31 32 28 35 4 221 28221 22 27 26 17 13 41 28221 282211712 1/2" = 1'-0" Reference: 1 / A-424 9ADA ROLL-IN SHOWER ELEV. D Units 338, 403 1/2" = 1'-0" Reference: 1 / A-424 10 ADA BATH ELEV. C Units 138, 238, 303, 503, 512 41 12 28221 28221 28221 221 221 8 7 7 2 686 11 29 15 28 22 1 17 2 23 13 22 24 14 17 1/2" = 1'-0" Reference: 1 / A-424 7ADA ROLL-IN SHOWER ELEV. B Units 338, 403 35 32 28 22 1 24 5 4 23 2 12 7 17 3 32 35 28 22 1 17 0'1' 2'4' SCALE: 1/2" = 1'-0" 321 1 7 29 2 2822 2822 35 3 2121 29 2 1 2228 6 1/2" = 1'-0" Reference: 1 / A-424 8ADA ROLL-IN SHOWER ELEV. A Units 338, 403 2 12 4 9 28 17 7 21 221 3 23 7 29 1 30 221 12 2 28 22 1 86 86 11 EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV Revision Schedule Number Description Date WC-02 HD-16 CT-01.17' - 6"HD-04 4 A-510 PF-13 PF-03 D-G03 WC-01 PT-03 PL-02 CT-01.1 CT-01.1 WC-02 HD-16 PF-03 GR-506 WC-02 WC-02 GR-326 HD-21PF-15 PF-13 HD-04 PF-03 PF-11 HD-08 HD-18.1 A-4256 4 10 8 A-425 5 94' - 10 3/4"3' - 4"3' - 1 1/4"4' - 0"VER. SHOWER PAN DIMENSIONS 5' - 0" 6' - 1" A-5105Sim HD-16 HD-21 HD-01 P1.2P1.1P1.1PF-07 PF-15 GR-506 HD-12 HD-12 4' - 6"PF-016' - 5"EQEQHD-18.1 PF-11 HD-08 HD-18 HD-05.2 D-G03 CT-01 ? D-G03 HD-04.1 EQEQ EQEQEQ EQCL-B27' - 6" CL-B27' - 6" PT-03 PL-02 WC-02 2' - 0"1' - 9"HD-01 D-G03 ℄ PF-01 WC-02 PT-03 PL-02 HD-21 GR-506 CT-01.1 0' - 5"1' - 5" GR-326 3' - 6"D-G03 GR-506 GR-326 WC-02 CT-01.1 A-42511 12 73' - 1 1/2"3' - 4"4' - 10 3/4"4' - 0"VER. TUB DIMENSIONS 5' - 0" 6' - 1" HD-16 EQEQHD-12 PF-06 PF-11 HD-08 PF-01 HD-01 HD-21 PF-07 PF-15 GR-506 ? D-G03 D-G03 HD-04.1 HD-12 HD-05 CT-01 P1.1 P1.1 P1.2 WC-02 PF-06 PF-14 HD-08 PF-13 PF-11 HD-05 HD-04 HD-16 CT-01.1 WC-02 CT-01.1 PL-02 PT-03 HD-12 HD-05 WC-01 HD-16 GR-506 GR-326 WC-01 WC-02 PF-11 HD-08 HD-18.1 PF-13 PF-14 PF-06 PF-15 HD-21 HD-05 HD-04 1/2" = 1'-0" Reference: 1 / A-414 4STUDIO BATH ELEV. A Units x04, x14, x16, x18-x21, x23, x25-x26, x30, x37 1/2" = 1'-0" Reference: 1 / A-425 6STUDIO BATH ELEV. B Units x04, x14, x16, x18-x21, x23, x25-x26, x30, x37 1/2" = 1'-0" Reference: 1 / A-425 10STUDIO BATH ELEV. D Units x04, x14, x16, x18-x21, x23, x25-x26, x30, x37 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216UNIT BATH - STUDIOBATH PLANS ANDINTERIOR ELEVATIONS A-425 FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 1/2" = 1'-0" Reference: 1 / A-414 1STUDIO BATHROOM PLAN Units x04, x14, x16, x18-x21, x23, x25-x26, x30, x37 FFL 1/2" = 1'-0" Reference: 3 / A-414 3STUDIO BATHROOM RCP Units x04, x14, x16, x18-x21, x23, x25-x26, x30, x37 FFL 1/2" = 1'-0" Reference: 1 / A-414 8STUDIO BATH ELEV. C Units x04, x14, x16, x18-x26, x30, x36-x37 1/2" = 1'-0" Reference: 1 / A-414 5STUDIO BATH ELEV. A1 Units x04, x14, x16, x18-x26, x30, x36-x37 1/2" = 1'-0" Reference: 1 / A-414 9STUDIO BATH ELEV. C1 Units x04, x14, x16, x18-x26, x30, x36-x37 KEYNOTES - UNIT BATHROOMS 1 WALL MOUNTED GRAB BARS REQUIREDCLEARANCES - 12" ABOVEAND 1-1/2" BELOW. REFER TO ACCESSIBILITYSTANDARDS & HADG 2 CURTAIN ROD 3 ACCESSIBLE SHOWER THRESHOLD. 1/2" MAXHEIGHT BEVELED 1:2 MAX. REFER TO HADG FORMORE INFORMATION 4 TOWEL/ROBE HOOK 5 DOUBLE TOILET PAPER HOLDER 6 ACCESSIBLE VANITY 7 ACCESSIBLE TUB/SHOWER SEAT. REFER TOACCESSIBILITY STANDARDS AND HADG FORREQUIREMENTS 8 CLEAR AREA OF SINK/VANITY MUST BEACCESSIBLE 9 ON/OFF - PRESSURE BALANCING VALVE ANDTEMPERATURE CONTROL. 10 SHOWER HEAD. "TWO-IN-ONE" SHOWER HEADWITH STATIONARY SHOWER HEAD PORTION ANDREMOVABLE HAND HELD SHOWER WAND 11 SHOWER DIVERTER VALVE 12 HAND SHOWER. HAND-HELD SHOWER UNITREQUIRED TO HAVE ON/OFF CONTROL WITHNON-POSITIVE SHUT OFF 13 VANITY LIGHTED MIRROR FIXTURE -- HARDWIREFIXTURE TO WALL- CONTRACTOR TO VERIFY JBOXTYPE TO ENSURE PROPER INSTALLATION ANDBACKING FOR ITEM KEYNOTED 14 GFCI OUTLETS 15 CORNER SOAP SHELF 17 BULK TOILETRY DISPENSERS 18 SHOWER ENCLOSURE W/ TEMPERED GLASS DOOR. 19 TOWEL BAR ON SHOWER SURROUND 20 FLOOR DRAIN LOCATION -- MAINTAIN ACCESSIBLECOMPLIANT SLOPES TO DRAIN 21 ADA ROLL-IN SHOWER BASE 22 FRAMING SUBCONTRACTOR TO PROVIDE 3/4" F.R.T.PLYWOOD BLOCKING TO RECEIVE ITEM INDICATED- EXTEND FULL LENGTH OF OBJECT 23 SHOWER SURROUND 24 TOILET 25 SHOWER BASE WITH LINEAR DRAIN 26 LAVATORY 27 FAUCET 28 GRAB BAR 29 BATHTUB 30 TUB FILL FAUCET 31 TOILET FLUSH HANDLE TO BE LOCATED ONAPPROACH SIDE 32 TOWEL BAR 33 IRON AND IRONING BOARD HANGER 34 CLOSET 35 BATH CADDY 36 SOAP DISH 37 FACIAL TISSUE COVER 38 SHAFT 39 WALL STOP 40 ALIGN 41 STATIONARY SHOWER HEAD. 1/2" = 1'-0" Reference: 1 / A-420 2STUDIO BATHTUB PLAN Units x22, x24, x36 1/2" = 1'-0" Reference: 2 / A-425 12 STUDIO BATHTUB ELEV. A Units x22, x24, x36 1/2" = 1'-0" Reference: 2 / A-425 7 STUDIO BATHTUB ELEV. B Units x22, x24, x36 1/2" = 1'-0" Reference: 2 / A-425 11 STUDIO BATHTUB ELEV. D Units x22, x24, x36 29 38 1322 4 23 25 17 14 25 18 22 2222 17 24 13 22 22 28 15 232323 2323 17 17 24 5 10 9 4 25 9 10 17 27 4 10 17 2213 13 24 18 17 28 9 10 17 4 25 38 26 36 37 17 31 24 27 17 4 18 5 4 2213 4 19 40 11 15 9 2822 22 26 36 37 17 31 24 27 5 4 2213 11 15 9 2822 324 22 32 40 2 40 EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV Revision Schedule Number Description Date 1' - 9"7" - 9" TOILET PAPER ROLL HOLDER FROM BACK OF WALL 2' - 0" SINGLE TOILET PAPER HOLDER 7" - 9"MIN.1' - 3"TOILET TISSUE DISPENSER HD 01HD 02HD 03U.O.N5' - 6"TOWEL HOOK SURFACE MOUNTED HD 04 SHOWER CURTAIN ROD HD 56' - 8" BOWED SHOWER ROD6' - 8" STRAIGHT ROD (ADA SHOWERS ONLY)HD 5.1 3' - 4" 4' - 6" MIN. 3' - 6"TOILET SEAT HEIGHT1 ' - 5" - 1' - 7"REQ'D CLEAR1' - 0"REQ'D CLEAR0' - 1 1/2"GRIPPING SURFACE2'-9" - 2'-0"MIN. 3' - 0"1'-6" MIN.3'-3" - 3'-5"1' - 5" 3' - 5" GRAB BAR(TOILET / 2-WALL AND VERTICAL)SURFACE MOUNTED HD 06 NOTE: TYP. CLEAR AREA AROUND GRAB BARS TO BE : ABOVE - 1'-0", BELOW - 1'-5" . BETWEEN, SHOWER CONTROLS, SHOWER FITTING, AND OTHER GRAB BARS A CLEAR DISTANCE OF 1.5" IS PERMITTED. MIN. 1' - 0" MIN. 2' - 0"REFER TO ELEVATIONS30" AFF1' - 6"EDGE OF TUB / SHOWER BELOW GRAB BAR3" - 6"6" - 12"REQ'D CLEAR0' - 1 1/2"REQ'D CLEAR0' - 1 1/2"LINE OF TUB8" - 10" MAX.FFL FFLREQ'D CLEAR1' - 0"3'-0" GRIPPING SURFACEGRAB BAR(TUB / SHOWER)SURFACE MTD. HD 08 MAX. 1' - 0"2' - 0"1' - 10" NOTE: TYP. CLEAR AREA AROUND GRAB BARS TO BE : ABOVE - 1'-0", BELOW - 1'-5" . BETWEEN, SHOWER CONTROLS, SHOWER FITTING, AND OTHER GRAB BARS A CLEAR DISTANCE OF 1.5" IS PERMITTED. 2 GRAB BARS(TUB )SURFACE MTD. HD 09 GRAB BAR(TUB )SURFACE MTD. HD 10 NOTE: ALL GRAB BARS MUST BE BLOCKED OR REINFORCED TO WITHSTAND ACCESSIBILITY REQT'S - REFER TO HADG REQ'D CLEAR0' - 1 1/2"REQ'D CLEAR1' - 0"T.O. GRIPPING SURFACE3' - 0"MAX. 0' - 6"3' - 0" GRAB BAR(SHOWER )SURFACE MTD. HD 11 NOTE: TYP. CLEAR AREA AROUND GRAB BARS TO BE : ABOVE - 1'-0"BELOW - 1'-5"ACC.3' - 4"U.O.N.5' - 0"ROBE HOOKSURFACE MTD. HD 12 AUTOMATIC PAPER TOWER DISPENSER HD 13TO SHEET OR TOP OF CONTROL4' - 0"INSTALL BOTH ACC. AND NON ACC. COAT HOOK IN ACC. PUBLIC EMPLOYEE BATH1' - 6"U.O.N3' - 5 1/4"LINE OF WALL MAX. 0' - 2 1/2" FOLDING SHOWER SEAT (SURFACE MOUNTED) HD 14 SOAP DISPENSER POOL RESTROOMS(SURFACE MOUNTED) HD 15 TO TOP OF BRACKET U.O.N2'-0" ACCESSIBLE SHOWERTYP. 0' - 5 1/2"TO TOP OF BRACKET U.O.N4'-0" STANDARD SHOWERTO TOP OF BRACKET U.O.N2'-9" ACCESSIBLE TUBSHAMPOO, CONDITIONER, SHOWER GEL DISPENSERS - SURFACE MOUNTED GUESTROOMS HD 16 TO OPERABLE PART3' - 10" MAX.NOTE: PROVIDE OVER HANDWASH SINK IN FOOD PREP PROVIDE ADEQUATE CLEARANCE FROM FAUCET AND SINK PAPER TOWEL /SOAP DISPENSERRECESSED HD 17 FFL15" A.F.FLINE OF WALL SHOWER FOOTRESTSURFACE MOUNTEDALL SHOWERS HD 18 NOTE: MUST NOT PROJECT MORE THAN 4" INTO ACCESSIBLE ROUTE 3'6" - 3'-10" MAX.RECESSED WASTERECEPTACLEPOOL RESTROOMS HD 19 REQ'D CLEAR 1' - 0"REQ'D CLEAR0' - 1 1/2"T.O GRIPPING SURFACE3' - 0"REQ'D CLEAR1' - 0"NOTE: MUST NOT PROJECT MORE THAN 4" INTO ACCESSIBLE ROUTE TO TOP OF BRACKET U.O.N4' - 0" U.O.NTYP 0' - 5 1/2" GRAB BAR (TUB)SURFACE MOUNTED HD 20 LOTION AND HAND GEL DISPENSERSURFACE MOUNTED GUESTROOMS HD 21 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216RESTROOMACCESSORY ANDMOUNTING DETAILS A-426 FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV Revision Schedule Number Description Date 5 6.1 C.1 F F G G E EC A-432 5 8 A-432 1 3 24 A-433 1 1 A-302 8.1 9 A-503 1 A-432A 1 2 2 3 4 63 67 A-43315 13 14 406 SF MEETING ROOM 120 81 SF MEETING STORAGE 119 172 SF WOMEN'SRESTROOM 115 171 SF MEN'SRESTROOM 116 176 SF ELEVATORLOBBY 117 64 SF ELEV 2 113 68 SF ELEV 1 111 2,670 SF LOBBY 121 150 SF VESTIBULE 122 A-433 A-7011 A-43312 9 10 11 A-437 1 A-7104 176 SF GUESTSTORAGE 118 7 8 6 10 H TYP PA-101 PA-100 TYP PA-105 TYP PA-102 TYP PA-102 TYP PA-103 TYP PA-104 TYP PA-103 TYP PA-104 TYP PA-108 TYP PA-107 TYP PA-105 PA-304 TYP PA-304 PA-302 PA-302 PA-302 PA-302 PA-306 PA-305 PA-300 PA-300 TYP PA-301 TYP PA-301 TYP PA-106 PA-303 TYP PA-106 PA-303 PA-111 PA-109 PA-307 PA-311 PA-309 TYP PA-110 PA-302 17 SF ICE/WATER 118A WP-01 WP-01 WP-01 WP-01 D-117 D-123 D-124D-120 D-122A PA-310 A-7101 PA-316 TYP PA-318A TYP PA-318 TYP OP-105 PA-317 2 A-301 2' - 2"3' - 2 3/4" 5' - 1 3/4"4' - 1 3/4" W-BCW-D 1' - 4"17' - 4 1/2"4' - 10"5' - 3 1/2"3' - 8"CW-K CW-D CW-E CW-E 12' - 10"25' - 4" CW-C 17' - 4 1/2"5' - 6 1/2"5' - 0"11' - 11 1/2"6' - 7 1/4"5' - 3 1/2"3' - 6 1/4"3' - 8 3/4"1' - 4 3/4"8' - 7 1/2" 1' - 2" D-115 D-116 8' - 7"1' - 1 3/4"1' - 4 3/4"3' - 10"1' - 10 3/4"1' - 4 3/4"16' - 10"0' - 10"42' - 3 1/2" 0' - 3 3/4" 1' - 11 1/2" 5' - 6" 4' - 10 3/4" 8' - 7" 1 A-505 2' - 4 1/4" K-99 K-505' - 2"9' - 4 1/4"<varies> P2.3 XE1/2 P5.4 P5.1 P7 P1.1 P3.1 P3.3 CW-C P2.2 XE1/2 XE1/2 XS4 P3.3 P1.2 P3.3 XS2XS2 P3.3 XE3 P3.1 1' - 9 1/4"8' - 7 1/2" 1' - 11" A-702 3 A-7031 A-706 1 CW-N CW-M CW-A2 CW-A1CW-B D-121 TYP PA-319 A-704 2 A-704 3 A-7013 A-701 3 XS4 XS1 A-70411 P1.2 OP-301 K-84 K-85 K-89 K-56 K-55 K-55.1 K-29 K-61 K-75 K-75 K-30K-72 K-60 K-67 K-87 3' - 6" PF-45 K-58 K-66 K-55.2 K-71 K-71 K-29 K-29.1 K-65 A-432A 4 5 7 8 8 A-705 5 8 7 6 13TYP. 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216ENLARGED PLAN -LOBBY, MEETINGROOM, RESTROOMS &STORAGE A-431 FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 0'2' 4'8' SCALE: 1/4" = 1'-0" 1/4" = 1'-0" Reference: 1 / A-122 1ENLARGED LOBBY PLAN FURNISHING SCHEDULE PUBLIC AREA FURNISHINGS PA-100 BENCH - DINING ROOM BANQUETTE PA-101 CHAIR - BANQUETTE PA-102 CHAIR - HIGH TOP BARSTOOL PA-103 CHAIR - BARREL LOUNGE CHAIR PA-104 CHAIR - LOUNGE PA-105 CHAIR - COUNTER HEIGHT STOOL PA-106 CHAIR - DINING TWO-TOP PA-107 CHAIR - TABLE HEIGHT STOOL PA-108 CHAIR - WORK TABLE STOOL PA-109 SOFA - LOBBY SECTIONAL PA-110 CHAIR - LOUNGE CHAIR PA-111 BENCH - RECEPTION PA-201 LAMP - LOBBY FLOOR LAMP PA-300 TABLE - BANQUETTE PA-301 TABLE - HIGH 4-TOP PA-302 TABLE - ROUND TEA HEIGHT PA-303 TABLE - DINING 2-TOP PA-304 TABLE - WINDOW COUNTER PA-305 TABLE - INDUCTION TABLE PA-306 TABLE - COMMUNAL WORK TABLE PA-307 TABLE - SOFA COFFEE TABLE PA-309 TABLE - SIDE TABLE AT SOFA PA-310 CASEWORK - COFFEE STATION PA-311 CASEWORK - ENTERTAINMENTCONSOLE PA-316 CASEWORK - PRINTER CABINET PA-317 CASEWORK - MEETING CONSOLE PA-318 MEETING ROOM TABLE - 6' LONG PA-318A MEETING ROOM TABLE - 8' LONG PA-319 RETAIL SHELVING PA-502 ART - PUBLIC RESTROOM- WOMEN'S PA-505 ART - 1ST FLOOR ELEVATOR LOBBY PA-506 MIRROR - PUBLIC RESTROOM VANITY PA-507 MIRROR - PUBLIC RESTROOM FULLHEIGHT PA-803 FIRE EXTINGUISHER - K CLASS - 2.5GAL HILTON SPECIFIED - OWNER FURNISHED OF-700 CHAIR - LOUNGE CHAIR UNDERCANOPY OF-705 TABLE - 17" D OUTDOOR SIDE TABLE OWNER SPECIFIED - OWNER FURNISHED OP-105 CHAIR - MEETING ROOM OP-301 POOL TABLE OP-703 LAUNDRY CART OP-704 BIKE RACK OP-705 FIRE EXTINGUISHER - ABC - 10 LBS OP-706 FIRE EXTINGUISHER CABINET KITCHEN EQUIPMENT K-25 HAND SINK WITH SPLASH GUARDS K-29 DOUBLE WAFFLE MAKER K-29.1 BATTER DISPENSER K-30 ELECTRIC JUICE DISPENSER K-50 COMMERCIAL MICROWAVE K-55 TAP WALL SPIGOT K-55.1 TAP WALL SCREEN K-55.2 4' WIDE DRIP PAN K-56 FROST TOP - UNDER COUNTERTOP K-58 BAKED GOODS DISPLAY K-60 POP-UP 4-SLICE TOASTER K-61 INDUCTION WARMER, DROP-IN K-65 CEREAL DISPENSER K-66 UNINSULATED BEVERAGE DISPENSER K-67 COFFEE DISPENSING URN K-71 CONDIMENT DISPENSER K-72 NAPKIN DISPENSER K-75 POS - CHECK-IN AND SUITE SHOP SALECOMPUTER K-84 REFRIGERATOR - SELF-SERVE - 36"WIDE K-85 REFRIGERATOR - SELF-SERVE - 47"WIDE K-87 DESKTOP PRINTER - OFFICE/SHOP K-89 SELF-SERVE FREEZER K-99 ICE AND WATER DISPENSER PLUMBING/MECHANICAL FIXTURES PF-09 URINAL - WALL MOUNTED PF-45 REFRIGERATED BOTTLE FILLER (CUPSPROVIDED) KEYNOTES - ENLARGED 1 2-WAY AREA OF REFUGE COMMUNICATION WITHFRONT DESK. 2 CARD READER TO CALL SERVICE ELEVATOR 3 CALL BUTTONS WITH LOCK PER AHJREQUIREMENTS. 4 ELEVATOR INDICATORS 5 AFTER-HOURS ACCESS INTERCOM-CONNECTED TO FRONT DESK. 6 KITCHEN HOOD VENT 7 FRP PANELS ON WALLS TO BE WELDED AT ALLSEAMS. ENSURE ALL SEAMS BETWEENDIFFERING MATERIALS ARE BACKED ANDSEALED IN ORDER TO MAINTAIN A SANITARY,WASHABLE ENVIRONMENT. 8 CLEAR TEMPERED, PLATED MIRROR 9 FLAT SCREEN TV. 10 PROVIDE ARTICULATING ARM FORWALL-MOUNTED TV. 11 PROVIDE FULL SUITES OF DATA/VIDEO/POWERUNDER AND BEWTEEN THE WINDOWS ALONGALL WALLS. 12 MACHINES TO BE SET UP FOR CARD ACCESSONLY. COORDINATE POWER AND DATA WITHSUPPLIER. 13 USE CORNER GUARDS ON ALL SURFACESFINISHED WITH WALL COVERING IN PUBLICAREAS. EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV Revision Schedule Number Description Date EH PT-12 CW-C CW-B D-121 CW-A2CW-A1 PL-01 7 8A-701 2 CT-12 PL-03 PT-12 WC-12 WC-12 WC-12 WC-12 K-55.1 K-55 K-29 K-30 K-89 K-85 K-84 K-50 PA-319 SS-01 CT-12 WC-12 CT-13 EH WC-12PL-01WC-12 CW-K D-120 PT-12WC-10 D-122A CW-N WP-01 78 WC-12 PT-12 A-7065 FGH WC-12WC-12 PT-12 A-706 4 A-7045 A-7047 98WC-12 A-706 2 CW-E CW-P 9 8WC-12 CW-E CW-P FGH PT-12 PT-12 PT-12 CW-D CW-D CW-N A-7041 PA-319CW-D PF-45 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216INTERIOR ELEVATIONS -LOBBY A-432 FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 0'2' 4'8' SCALE: 1/4" = 1'-0" 1/4" = 1'-0" Reference: 1 / A-431 1LOBBY NORTH ELEVATION OF EXTERIOR WALL North Wall in Lobby (Room 121) 1/4" = 1'-0" Reference: 1 / A-407 2 LOBBY EAST ELEVATION TOWARDS GUEST CORRIDOR East Wall in Lobby- Tap Wall and Suite Shop (Room 121) 1/4" = 1'-0" Reference: 1 / A-431 3LOBBY SOUTH ELEVATION TOWARDS INTERIOR Breakfast Area and Seating in Lobby (Room 121) 1/4" = 1'-0" Reference: 1 / A-407 4 LOBBY WEST ELEVATION TOWARDS INTERIOR Suite Shop and Breakfast Area in Lobby (Room 121) FFL FFL FFL 1/4" = 1'-0" Reference: 1 / A-431 5LOBBY NORTH ELEVATION TOWARDS INTERIOR 1/4" = 1'-0" Reference: 1 / A-431 6LOBBY / VESTIBULE EAST ELEVATION Reception Desk and Vestibule FFL 1/4" = 1'-0" Reference: 1 / A-431 7 LOBBY / VESTIBULE WEST ELEVATION Waiting Area and Vestibule 1/4" = 1'-0" Reference: 1 / A-431 8LOBBY SOUTH ELEVATION OF EXTERIOR WALL EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV Revision Schedule Number Description Date FGE KHJ WC-10 WP-1 WC-12 OP-706 D-123 PL-11 PT-11 PA-310 RB-10 78 PT-12 WC-12 OP-301 WP-1WP-1 978 PUBLIC CORRIDOR BEYOND RB-10RB-10RB-10 WC-12WC-12WC-12 1' - 0"A-510 11Typ13 A-5107 A-704 ART WALL PA-500 FG EKHJ A-7063 WC-10 RB-10 WC-12 CW-K D-120 WC-12 WC-10 D-124D-128 PC-04 PT-12 WP-1PT-11PL-11PT-11PL-11 G 2 A-301 D-122A CW-N PC-04 9 CW-P CW-E WC-10 CT-10.1 PC-04 G 2 A-301 D-122 CW-M PC-04 9 WC-10PC-04 CW-E CW-P CT-10.1 EQ EQ 3' - 10"5 ACT ACOUSTIC CEILING TILEASALUMINUM STOREFRONTCGCORNER GUARDCONC CONCRETE, UNFINISHEDCPCARPETCPTCARPET TILECSCONCRETE, FINISHEDGWBGYPSUM WALL BOARDFCFIBER CEMENTFRPFIBERGLASS-REINFORCEDPLASTICMR GWB MOISTURE-RESISTANT GYPSUM WALL BOARDPLPLASTIC LAMINATEPTPAINT/POWDER COATQTQUARRY TILERBRUBBER BASERESRESILIENT TILE FLOORSCSTAMPED CONCRETESFSPECIALTY FINISH (KNOCK DOWN)SS ENGINEERED SOLID SURFACESTSTONESTLSTAINLESS STEELSTRUC STRUCTURE ABOVEVCTVINYL COMPOSITE TILEWCVINYL WALL COVERINGWDWOOD-LOOK ALUMINUM SLATS AND BATTENSWPSCREEN WALL NOTE: REFER TO FF&E PACKAGE AND SPECIFICATION BOOK FOR FURNITURE AND FINISH SPECIFICATIONS FINISH LEGEND FFL FFL 1/4" = 1'-0" Reference: 1 / A-431 1LOBBY NORTH ELEVATION THROUGH CENTRAL CIRCULATION 1/4" = 1'-0" Reference: 1 / A-403 3LOBBY EAST ELEVATION TOWARDS INTERIOR 1/4" = 1'-0" Reference: 1 / A-403 6LOBBY WEST ELEVATION TOWARD PUBLIC CORRIDOR FFL 1/4" = 1'-0" Reference: 1 / A-431 2LOBBY SOUTH ELEVATION THROUGH CENTRAL CIRCULATION FFL 1/4" = 1'-0" Reference: 1 / A-407 4VESTIBULE NORTH ELEVATION Room 122 1/4" = 1'-0" Reference: 1 / A-407 5 VESTIBULE EAST ELEVATION Room 122 0'2' 4'8' SCALE: 1/4" = 1'-0" 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216INTERIOR ELEVATIONS -LOBBY, VESTIBULE A-432A FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 FURNISHING SCHEDULE GUESTROOM FURNISHINGS GR-201 SCONCE - NIGHTSTAND GR-307 NIGHTSTAND - SMALL GR-308 NIGHTSTAND - REGULAR GR-319 CLOSET - EFFICIENCY SUITE GR-325 VANITY - EFFICIENCY SUITE GR-326 VANITY - STUDIO AND 1-BEDROOMSUITES GR-506 MIRROR - GUESTROOM FULL LENGTH GR-907 CLOCK/RADIO GR-908 TELEPHONE - GUESTROOM GR-ES BED - EFFICIENCY (GR-300, 303, 600) PUBLIC AREA FURNISHINGS PA-100 BENCH - DINING ROOM BANQUETTE PA-101 CHAIR - BANQUETTE PA-102 CHAIR - HIGH TOP BARSTOOL PA-103 CHAIR - BARREL LOUNGE CHAIR PA-104 CHAIR - LOUNGE PA-105 CHAIR - COUNTER HEIGHT STOOL PA-106 CHAIR - DINING TWO-TOP PA-107 CHAIR - TABLE HEIGHT STOOL PA-108 CHAIR - WORK TABLE STOOL PA-109 SOFA - LOBBY SECTIONAL PA-110 CHAIR - LOUNGE CHAIR PA-111 BENCH - RECEPTION PA-200 PENDANT LIGHT - RECEPTION PA-201 LAMP - LOBBY FLOOR LAMP PA-204 SCONCE - PUBLIC AREAS PA-300 TABLE - BANQUETTE PA-301 TABLE - HIGH 4-TOP PA-302 TABLE - ROUND TEA HEIGHT PA-303 TABLE - DINING 2-TOP PA-304 TABLE - WINDOW COUNTER PA-305 TABLE - INDUCTION TABLE PA-306 TABLE - COMMUNAL WORK TABLE PA-307 TABLE - SOFA COFFEE TABLE PA-309 TABLE - SIDE TABLE AT SOFA PA-310 CASEWORK - COFFEE STATION PA-311 CASEWORK - ENTERTAINMENTCONSOLE PA-316 CASEWORK - PRINTER CABINET PA-317 CASEWORK - MEETING CONSOLE PA-318 MEETING ROOM TABLE - 6' LONG PA-318A MEETING ROOM TABLE - 8' LONG PA-319 RETAIL SHELVING PA-400A ROLLER SHADE - LOBBY - MANUAL,SHEER, CEILING MOUNT, 4' - 5" W PA-400B ROLLER SHADE - LOBBY - MANUAL,SHEER, CEILING MOUNT, 4' - 1" W PA-400D ROLLER SHADE - LOBBY - MANUAL,SHEER, CEILING MOUNT, 3' - 10.25" W PA-401 ROLLER SHADE - PUBLIC/BOH -MANUAL, SHEER, WALL MOUNT, 5' W PA-405 ROLLER SHADE - MEETING ROOMENTRY - MANUAL, SHEER, CEILINGMOUNT, 3' - 1.5" W PA-500 ART - CENTRAL HUB BANQUETTE PA-505 ART - 1ST FLOOR ELEVATOR LOBBY PA-803 FIRE EXTINGUISHER - K CLASS - 2.5GAL OWNER SPECIFIED - OWNER FURNISHED OP-105 CHAIR - MEETING ROOM OP-301 POOL TABLE OP-704 BIKE RACK OP-705 FIRE EXTINGUISHER - ABC - 10 LBS OP-706 FIRE EXTINGUISHER CABINET KITCHEN EQUIPMENT K-01 WIRE SHELVING - 24"X60" WITH FEET K-04 WIRE SHELVING - 24" X 60" WITHLOCKING CAGE AND CASTERS K-05 BAR BACK COOLER K-07 WALK IN REFRIGERATOR K-10 WIRE SHELVING - 24" X 36" WITHCASTERS K-13 FAUCET WITH WALL BRACKET 1/4" = 1'-0" Reference: 1 / A-101 7VESTIBULE SOUTH ELEVATION Room 122 1/4" = 1'-0" Reference: 1 / A-407 8 VESTIBULE WEST ELEVATION Room 122 FURNISHING SCHEDULE K-15 WIRE SHELVING - 24" X 48" WITHCASTERS K-16 3 COMPARTMENT SINK WITH WORKTABLE AND DRYING AREA K-17 STAINLESS STEEL WALL SHELVES K-18 FLOOR TROUGH - 48" X 12" K-19 PRERINSE SPRING WITH WALLBRACKET AND FAUCET K-20 DISPOSER K-22 UNDERCOUNTER DISHWASHER K-25 HAND SINK WITH SPLASH GUARDS K-26 ICE MAKER - CUBELET K-27 ICE STORAGE BIN K-28 FLOOR TROUGH - 24" X 12" K-29 DOUBLE WAFFLE MAKER K-29.1 BATTER DISPENSER K-30 ELECTRIC JUICE DISPENSER K-31 REFRIGERATED DRAWERS ANDWORKTOP K-32 2-CARAFE COMMERCIAL COFFEEMAKER K-33 STAINLESS STEEL WALL SHELVES K-36 STAINLESS STEEL WALL SHELVES K-39 WORK TABLE W/ PREP SINKS K-40 STAINLESS STEEL WALL SHELVES K-41 REACH IN FREEZER- 3 DOOR K-42 ELECTRIC CONVECTION OVEN - FULLSIZE SHEET PAN K-43 ELECTRIC PROOFER AND HOLDINGCABINET - FULL SIZE SHEET PAN K-45 WORK TABLE WITH PREP SINK K-47 PASTA COOKER - 2.5 GAL K-49 INDUCTION RANGE, COUNTERTOP K-50 COMMERCIAL MICROWAVE K-51 CLASS 1 KITCHEN HOOD K-55 TAP WALL SPIGOT K-55.1 TAP WALL SCREEN K-55.2 4' WIDE DRIP PAN K-56 FROST TOP - UNDER COUNTERTOP K-58 BAKED GOODS DISPLAY K-60 POP-UP 4-SLICE TOASTER K-61 INDUCTION WARMER, DROP-IN K-65 CEREAL DISPENSER K-66 UNINSULATED BEVERAGE DISPENSER K-67 COFFEE DISPENSING URN K-71 CONDIMENT DISPENSER K-72 NAPKIN DISPENSER K-75 POS - CHECK-IN AND SUITE SHOP SALECOMPUTER K-75A POUR MY BEER CONTROL CENTER K-84 REFRIGERATOR - SELF-SERVE - 36"WIDE K-85 REFRIGERATOR - SELF-SERVE - 47"WIDE K-87 DESKTOP PRINTER - OFFICE/SHOP K-89 SELF-SERVE FREEZER PLUMBING/MECHANICAL FIXTURES PF-01 TOILET - GUESTROOM PF-03 SHOWER BASE - 60" X 36" WITH LINEARDRAIN PF-07 LAVATORY - UNDERMOUNT, 20" X 14" PF-11 SHOWER HEAD - 2 IN 1 PF-13 SHOWER/TUB VALVE & CONTROL PF-15 FAUCET - LAVATORY PF-45 REFRIGERATED BOTTLE FILLER (CUPSPROVIDED) TOILET ACCESSORIES HD-01 DUAL TOILET PAPER HOLDER HD-04 WALL-MOUNTED ROBE HOOK HD-05.2 SLIDING SHOWER DOOR HD-08 18" GRAB BAR HD-18.1 SOAP SHELF HD-21 BULK AMENITY DISPENSER ATLAVATORIES KEYNOTES - ENLARGED 1 2-WAY AREA OF REFUGE COMMUNICATION WITHFRONT DESK. 2 CARD READER TO CALL SERVICE ELEVATOR 3 CALL BUTTONS WITH LOCK PER AHJREQUIREMENTS. 4 ELEVATOR INDICATORS 5 AFTER-HOURS ACCESS INTERCOM-CONNECTED TO FRONT DESK. 6 KITCHEN HOOD VENT 7 FRP PANELS ON WALLS TO BE WELDED AT ALLSEAMS. ENSURE ALL SEAMS BETWEENDIFFERING MATERIALS ARE BACKED ANDSEALED IN ORDER TO MAINTAIN A SANITARY,WASHABLE ENVIRONMENT. 8 CLEAR TEMPERED, PLATED MIRROR 9 FLAT SCREEN TV. 10 PROVIDE ARTICULATING ARM FORWALL-MOUNTED TV. 11 PROVIDE FULL SUITES OF DATA/VIDEO/POWERUNDER AND BEWTEEN THE WINDOWS ALONGALL WALLS. 12 MACHINES TO BE SET UP FOR CARD ACCESSONLY. COORDINATE POWER AND DATA WITHSUPPLIER. 13 USE CORNER GUARDS ON ALL SURFACESFINISHED WITH WALL COVERING IN PUBLICAREAS. EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV Revision Schedule Number Description Date E D-120 CW-K WC-10WC-10 PA-317 PC-04 11' - 0"910 WC-10WC-10 E PT-12 RB-10 W-B W-B PA-401 PA-401 PA-318APA-318 RB-10 D-119 WC-10 PL-11 PT-11 WC-11WC-12 RB-10 K-998' - 0"8' - 0"10' - 0"PL-04PL-03PL-01PL-04PL-01 C.1A-704 4 WC-12WC-12 WC-12 WC-11 RB-10 PL-11 PT-11 D-115 K-99 PL-01 PL-01 WC-12 WC-12 RB-10 WC-11 K-99 C.1 OPEN TO CORRIDOR BEYONDD-116 WC-12 PL-11PT-11CT-10.1 WC-12A-702 5 D-117 PT-11 RB-10 PC-04 OPEN TO LOBBY BEYOND 7 WC-11 RB-10 PA-505 3' - 6"6' - 0"ART EQEQ WALL OPEN TO CORRIDOR 7 RB-10 WC-11 ELEVATOR DOOR ELEVATOR DOOR 3' - 10"EQ EQ 2 7' - 0"6' - 0"PA-204 PA-2044 3 3' - 10"C.1 PT-03 RB-10 PT-03 RB-10 C.1 PT-03 PT-03 RB-10RB-10 PT-03 PL-11 PT-11 RB-10 D-119 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216INTERIOR ELEVATIONS -MTG. ROOM & STO,ELEVATOR LOBBY,GUEST STO. A-433 FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 0'2' 4'8' SCALE: 1/4" = 1'-0" 1/4" = 1'-0" Reference: 1 / A-431 1MEETING ROOM NORTH ELEVATION Room 120 1/4" = 1'-0" Reference: 1 / A-431 2MEETING ROOM EAST ELEVATION Room 120 1/4" = 1'-0" Reference: 1 / A-431 3MEETING ROOM SOUTH ELEVATION Room 120 1/4" = 1'-0" Reference: 1 / A-431 4 MEETING ROOM WEST ELEVATION Room 120 1/4" = 1'-0" Reference: 1 / A-431 10GUEST STORAGE EAST ELEVATION Rooms 118 & 118A 1/4" = 1'-0" Reference: 1 / A-431 11GUEST STORAGE SOUTH ELEVATION Rooms 118 & 118A 1/4" = 1'-0" Reference: 1 / A-431 12 GUEST STORAGE WEST ELEVATION Rooms 118 & 118A 1/4" = 1'-0" Reference: 1 / A-431 9GUEST STORAGE NORTH ELEV. Rooms 118 & 118A FFL FFL FFL 1/4" = 1'-0" Reference: 1 / A-431 13ELEVATOR LOBBY, 1ST FLR, N.ELEV. Room 117 1/4" = 1'-0" Reference: 1 / A-403 14ELEVATOR LOBBY, 1ST FLR, EAST ELEV. Room 117 1/4" = 1'-0" Reference: 1 / A-403 15 ELEVATOR LOBBY, 1ST FLR, WEST ELEV. Room 117 FFL 1/4" = 1'-0" Reference: 1 / A-101 7MTG RM STORAGE SOUTH ELEVATION Room 119 1/4" = 1'-0" Reference: 1 / A-101 8 MTG RM STORAGE WEST ELEVATION Room 119 1/4" = 1'-0" Reference: 1 / A-101 5MTG RM STORAGE NORTH ELEVATION Room 119 1/4" = 1'-0" Reference: 1 / A-101 6MTG RM STORAGE EAST ELEVATION Room 119 FURNISHING SCHEDULE PUBLIC AREA FURNISHINGS PA-100 BENCH - DINING ROOM BANQUETTE PA-101 CHAIR - BANQUETTE PA-105 CHAIR - COUNTER HEIGHT STOOL PA-106 CHAIR - DINING TWO-TOP PA-203 PENDANT LIGHT - PUBLIC RESTROOM PA-204 SCONCE - PUBLIC AREAS PA-300 TABLE - BANQUETTE PA-303 TABLE - DINING 2-TOP PA-304 TABLE - WINDOW COUNTER PA-311 CASEWORK - ENTERTAINMENTCONSOLE PA-316 CASEWORK - PRINTER CABINET PA-317 CASEWORK - MEETING CONSOLE PA-318 MEETING ROOM TABLE - 6' LONG PA-318A MEETING ROOM TABLE - 8' LONG PA-400A ROLLER SHADE - LOBBY - MANUAL,SHEER, CEILING MOUNT, 4' - 5" W PA-401 ROLLER SHADE - PUBLIC/BOH -MANUAL, SHEER, WALL MOUNT, 5' W PA-405 ROLLER SHADE - MEETING ROOMENTRY - MANUAL, SHEER, CEILINGMOUNT, 3' - 1.5" W PA-500 ART - CENTRAL HUB BANQUETTE PA-502 ART - PUBLIC RESTROOM- WOMEN'S PA-505 ART - 1ST FLOOR ELEVATOR LOBBY PA-507 MIRROR - PUBLIC RESTROOM FULLHEIGHT OWNER SPECIFIED - OWNER FURNISHED OP-105 CHAIR - MEETING ROOM OP-705 FIRE EXTINGUISHER - ABC - 10 LBS OP-706 FIRE EXTINGUISHER CABINET KITCHEN EQUIPMENT K-99 ICE AND WATER DISPENSER TOILET ACCESSORIES HD-13 AUTOMATIC PAPER TOWEL DISPENSER KEYNOTES - ENLARGED 1 2-WAY AREA OF REFUGE COMMUNICATION WITHFRONT DESK. 2 CARD READER TO CALL SERVICE ELEVATOR 3 CALL BUTTONS WITH LOCK PER AHJREQUIREMENTS. 4 ELEVATOR INDICATORS 5 AFTER-HOURS ACCESS INTERCOM-CONNECTED TO FRONT DESK. 6 KITCHEN HOOD VENT 7 FRP PANELS ON WALLS TO BE WELDED AT ALLSEAMS. ENSURE ALL SEAMS BETWEENDIFFERING MATERIALS ARE BACKED ANDSEALED IN ORDER TO MAINTAIN A SANITARY,WASHABLE ENVIRONMENT. 8 CLEAR TEMPERED, PLATED MIRROR 9 FLAT SCREEN TV. 10 PROVIDE ARTICULATING ARM FORWALL-MOUNTED TV. 11 PROVIDE FULL SUITES OF DATA/VIDEO/POWERUNDER AND BEWTEEN THE WINDOWS ALONGALL WALLS. 12 MACHINES TO BE SET UP FOR CARD ACCESSONLY. COORDINATE POWER AND DATA WITHSUPPLIER. 13 USE CORNER GUARDS ON ALL SURFACESFINISHED WITH WALL COVERING IN PUBLICAREAS. EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV Revision Schedule Number Description Date 594 SF FOOD PREP 123 46 SF COURTYARDSTORAGE 141 135 SF ELECTRICAL 128 233 SF OPEN OFFICE 124 104 SF OWNER'SOFFICE 127 95 SF GM OFFICE 125 106 SF SALES OFFICE 126 A-434A 1 4 56 A-443 9 11 1012 A-434 14 16 1517 A-434 10 12 1113 A-434 1 3 24 A-4349 6 7 8 A-434A 9 7 108 28' - 8 1/2" 162 SF PUBLICCORRIDOR 121A D-139 CW-J 9 K 7 8 6 10 H J D-124 D-125D-126 D-127 D-128 P1.2 P1.2 P1.2 P1.2 P3.3 TRASH/BUSSING 20' - 11 1/4"D-1233' - 10 3/4"1' - 10 3/4"2' - 9"13' - 1 3/4"9' - 11 1/2"1' - 11 3/4"3' - 3"6' - 0"1' - 9 3/4" 2' - 2 1/2" 8' - 1 1/4" 1' - 9 3/4" 3' - 3"5' - 9 1/2"1' - 4 1/4"8' - 7 1/2"7' - 2 3/4"3' - 2 1/2"10' - 7 1/2"4' - 3 1/2"0' - 11 1/2"5' - 2"2' - 2 3/4"3' - 8 1/2"10' - 8 3/4"1' - 9"W-BW-B W-B D-141 A-703 1 K-05 K-56 K-07 K-04 K-15 K-15 K-01 K-01K-01 K-01 K-02 K-84 K-85 K-89 K-50 K-55 K-55.1 K-11 K-10K-50 K-14 K-25 K-25 K-18 K-28 K-26K-27 K-02 K-05 K-42K-45 K-43K-49K-47 K-22 K-22 K-16 K-41 K-32K-49 K-29 K-29 K-30 A-434A32 P3.3 XD1 XE3 P3.3 P8 P8PA-803 QT-01 CT-10 CPT-14CS-01 K-55.2 K-31 K-39 K-29.1 K-75A J 2' - 4"OP-705 D-124 PT-03PT-03PT-03PF-11PF-11 RB-10RB-109' - 0"RB-10 PT-03 J D-127 D-126 D-125 PF-03 PF-03 PF-03PF-03 PF-03 PF-03 RB-10RB-10 PT-03 PT-03 PT-03PT-03PT-03 RB-10 RB-10 RB-103' - 0"1' - 8"4' - 8"OP-705 K-75A K-87 HD-04 6' - 9" 2' - 6" OP-103OP-102 OP-101 PF-03PF-03 RB-10 PT-03PT-03 D-125 PA-401 OP-101 OP-102OP-102 OP-103 PT-03 RB-10 RB-10 PT-03PA-401 OP-102 OP-101 OP-103 W-B OP-103 OP-102OP-102 PA-401 PT-03PT-03 RB-10 J D-126 OP-103 OP-102 OP-101 PT-03 RB-109' - 0"PF-03PF-03 9 PT-03 RB-10 J PA-401 OP-101 OP-102 OP-103RB-10 PT-03 PT-03 W-B 9 TYP OP-102OP-103 OP-101 RB-10 PT-03PA-401 PT-03 RB-10 D-127 OP-103OP-101OP-102 PT-03 PF-03PF-03RB-10 9PT-03 PT-03 RB-10 RB-10 PA-401 OP-101 OP-103 OP-102 W-B OP-102OP-103OP-101 PA-401 PT-03 RB-10 9 PT-03 RB-10 9' - 0"ACTACOUSTIC CEILING TILEASALUMINUM STOREFRONTCGCORNER GUARDCONC CONCRETE, UNFINISHEDCPCARPETCPTCARPET TILECSCONCRETE, FINISHEDGWBGYPSUM WALL BOARDFCFIBER CEMENTFRPFIBERGLASS-REINFORCEDPLASTICMR GWB MOISTURE-RESISTANT GWBPFPRE-FINISHED DOORPLPLASTIC LAMINATEPTPAINT/POWDER COATQTQUARRY TILERBRUBBER BASERESRESILIENT TILE FLOORSCSTAMPED CONCRETESFSPECIALTY FINISH (KNOCK DOWN)SSENGINEERED SOLID SURFACESTSTONESTLSTAINLESS STEELSTRUC STRUCTURE ABOVEVCTVINYL COMPOSITE TILEWCVINYL WALL COVERINGWDWOOD-LOOK ALUMINUM SLATS AND BATTENSWPSCREEN WALL NOTE: REFER TO FF&E PACKAGE AND SPECIFICATION BOOK FOR FURNITURE AND FINISH SPECIFICATIONS FINISH LEGEND 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216ENLARGED PLAN &INTERIOR ELEVATIONS -OFFICES AND FOODPREP A-434 FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 0'2' 4'8' SCALE: 1/4" = 1'-0" 1/4" = 1'-0" Reference: 1 / A-122 5OFFICES AND FOOD PREP PLAN 1/4" = 1'-0" Reference: 1 / A-431 1OPEN OFFICE NORTH ELEVATION Room 124 1/4" = 1'-0" Reference: 5 / A-434 2OPEN OFFICE EAST EL. Room 124 1/4" = 1'-0" Reference: 1 / A-431 3 OPEN OFFICE SOUTH ELEVATION Room 124 1/4" = 1'-0" Reference: 5 / A-434 4 OPEN OFFICE WEST ELEVATION Room 124 1/4" = 1'-0" Reference: 2 / A-408 6GM OFFICE N. ELEV. Room 125 1/4" = 1'-0" Reference: 2 / A-408 7GM OFFICE E. ELEV. Room 125 1/4" = 1'-0" Reference: 2 / A-408 8 GM OFFICE S. ELEV. Room 125 1/4" = 1'-0" Reference: 5 / A-434 9 GM OFFICE W. ELEV. Room 125 1/4" = 1'-0" Reference: 5 / A-434 10SALES OFFICE N. ELEV. Room 126 1/4" = 1'-0" Reference: 5 / A-434 11SALES OFFICE E. ELEV. Room 126 1/4" = 1'-0" Reference: 5 / A-434 12 SALES OFFICE S. ELEV. Room 126 1/4" = 1'-0" Reference: 5 / A-434 13 SALES OFFICE W. ELEV. Room 126 1/4" = 1'-0" Reference: 5 / A-434 14OWNER'S OFFICE N. ELEV. Room 127 1/4" = 1'-0" Reference: 5 / A-434 15OWNER'S OFFICE E. ELEV. Room 127 1/4" = 1'-0" Reference: 5 / A-434 16 OWNER'S OFFICE S. ELEV. Room 127 1/4" = 1'-0" Reference: 5 / A-434 17 OWNER'S OFFICE W. ELEV. Room 127 FURNISHING SCHEDULE GUESTROOM FURNISHINGS GR-201 SCONCE - NIGHTSTAND GR-308 NIGHTSTAND - REGULAR GR-KS BED - KING (GR-301, 303, 600) PUBLIC AREA FURNISHINGS PA-107 CHAIR - TABLE HEIGHT STOOL PA-319 RETAIL SHELVING PA-401 ROLLER SHADE - PUBLIC/BOH - MANUAL, SHEER,WALL MOUNT, 5' W PA-803 FIRE EXTINGUISHER - K CLASS - 2.5 GAL HILTON SPECIFIED - OWNER FURNISHED OF-700 CHAIR - LOUNGE CHAIR UNDER CANOPY OWNER SPECIFIED - OWNER FURNISHED OP-101 CHAIR - OFFICE OP-102 CHAIR - GUEST OP-103 OFFICE DESK OP-704 BIKE RACK OP-705 FIRE EXTINGUISHER - ABC - 10 LBS OP-706 FIRE EXTINGUISHER CABINET KITCHEN EQUIPMENT K-01 WIRE SHELVING - 24"X60" WITH FEET K-02 KEG COOLER POWER PACK K-04 WIRE SHELVING - 24" X 60" WITH LOCKING CAGEAND CASTERS K-05 BAR BACK COOLER K-07 WALK IN REFRIGERATOR K-10 WIRE SHELVING - 24" X 36" WITH CASTERS K-11 WIRE SHELVING - 24" X 30" WITH CASTERS K-13 FAUCET WITH WALL BRACKET K-14 MOP SINK CABINET K-15 WIRE SHELVING - 24" X 48" WITH CASTERS K-16 3 COMPARTMENT SINK WITH WORK TABLE ANDDRYING AREA K-18 FLOOR TROUGH - 48" X 12" K-19 PRERINSE SPRING WITH WALL BRACKET ANDFAUCET K-20 DISPOSER K-22 UNDERCOUNTER DISHWASHER K-25 HAND SINK WITH SPLASH GUARDS K-26 ICE MAKER - CUBELET K-27 ICE STORAGE BIN K-28 FLOOR TROUGH - 24" X 12" K-29 DOUBLE WAFFLE MAKER K-29.1 BATTER DISPENSER K-30 ELECTRIC JUICE DISPENSER K-31 REFRIGERATED DRAWERS AND WORKTOP K-32 2-CARAFE COMMERCIAL COFFEE MAKER K-39 WORK TABLE W/ PREP SINKS K-41 REACH IN FREEZER- 3 DOOR K-42 ELECTRIC CONVECTION OVEN - FULL SIZE SHEETPAN K-43 ELECTRIC PROOFER AND HOLDING CABINET -FULL SIZE SHEET PAN K-45 WORK TABLE WITH PREP SINK K-47 PASTA COOKER - 2.5 GAL K-49 INDUCTION RANGE, COUNTERTOP K-50 COMMERCIAL MICROWAVE K-55 TAP WALL SPIGOT K-55.1 TAP WALL SCREEN K-55.2 4' WIDE DRIP PAN K-56 FROST TOP - UNDER COUNTERTOP K-71 CONDIMENT DISPENSER K-75A POUR MY BEER CONTROL CENTER K-84 REFRIGERATOR - SELF-SERVE - 36" WIDE K-85 REFRIGERATOR - SELF-SERVE - 47" WIDE K-87 DESKTOP PRINTER - OFFICE/SHOP K-89 SELF-SERVE FREEZER TOILET ACCESSORIES HD-04 WALL-MOUNTED ROBE HOOK HD-18 FOOT LEDGE FOR SHOWER HD-18.1 SOAP SHELF KEYNOTES - ENLARGED 1 2-WAY AREA OF REFUGE COMMUNICATION WITHFRONT DESK. 2 CARD READER TO CALL SERVICE ELEVATOR 3 CALL BUTTONS WITH LOCK PER AHJREQUIREMENTS. 4 ELEVATOR INDICATORS 5 AFTER-HOURS ACCESS INTERCOM- CONNECTEDTO FRONT DESK. 6 KITCHEN HOOD VENT. GC TO SUPPLY ANDINSTALL HOOD, MAU-01 AND EF-03 (SEEMECHANICAL). 7 FRP PANELS ON WALLS TO BE SEALED AT ALLSEAMS. ENSURE ALL SEAMS BETWEENDIFFERING MATERIALS ARE BACKED ANDSEALED IN ORDER TO MAINTAIN A SANITARY,WASHABLE ENVIRONMENT. 8 CLEAR TEMPERED, PLATED MIRROR 9 FLAT SCREEN TV. 10 PROVIDE ARTICULATING ARM FORWALL-MOUNTED TV. 11 PROVIDE FULL SUITES OF DATA/VIDEO/POWERUNDER AND BEWTEEN THE WINDOWS ALONGALL WALLS. 12 MACHINES TO BE SET UP FOR CARD ACCESSONLY. COORDINATE POWER AND DATA WITHSUPPLIER. 13 USE CORNER GUARDS ON ALL SURFACESFINISHED WITH WALL COVERING IN PUBLICAREAS. 14 BOX IN AROUND TOP OF WALK-INREFRIGERATOR EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV 2 2 2 2 2 2 2 2 REVISION SCHEDULE # DESCRIPTION DATE 2 ADDENDUM 2 6/21/2024 KJ K-07 K-25 K-22 K-16 K-14 K-41 K-15 QT-01.1 K-11 FRP-01FRP-01FRP-01FRP-01P1.214 K-26 K-25 K-32 K-04 K-15K-15 K-07 K-51 FRP-01FRP-01 QT-01.1 PA-803 K-31K-0211' - 0"0' - 8 3/4"P1.2 146J K-27 K-26 K-50 K-25 K-10 K-41K-42 K-51 K-45 K-43 K-47 K-49 K-32 D-123 K-16 K-22 FRP-01 QT-01.1PA-803 K-31 PF-11 PF-11 11' - 0"6 K-41 K-05 K-02 FRP-01 QT-01.1PA-803 11' - 0"K-33 K-33 7TYP. J 14' - 8 3/4"PT-11 RB-10 D-141 PC-B PC-B 66 RB-10 PT-11 3' - 2 3/4" 6 PT-11 RB-10 6 6 RB-10 PT-11 K-51 K-26 K-27 K-41 K-25 QT-01.1 FRP-01 FRP-01 QT-01.1 K-39 K-17 K-17 K-40 11' - 0"K-14K-11 K-16 K-22K-22 K-10 FRP-01 QT-01.1 K-20 K-13 K-19 K-17K-17 K-36K-40 ACT ACOUSTIC CEILING TILEASALUMINUM STOREFRONTCGCORNER GUARDCONC CONCRETE, UNFINISHEDCPCARPETCPTCARPET TILECSCONCRETE, FINISHEDGWBGYPSUM WALL BOARDFCFIBER CEMENTFRPFIBERGLASS-REINFORCEDPLASTICMR GWB MOISTURE-RESISTANT GWBPFPRE-FINISHED DOORPLPLASTIC LAMINATEPTPAINT/POWDER COATQTQUARRY TILERBRUBBER BASERESRESILIENT TILE FLOORSCSTAMPED CONCRETESFSPECIALTY FINISH (KNOCK DOWN)SS ENGINEERED SOLID SURFACESTSTONESTLSTAINLESS STEELSTRUC STRUCTURE ABOVEVCTVINYL COMPOSITE TILEWCVINYL WALL COVERINGWDWOOD-LOOK ALUMINUM SLATS AND BATTENSWPSCREEN WALL NOTE: REFER TO FF&E PACKAGE AND SPECIFICATION BOOK FOR FURNITURE AND FINISH SPECIFICATIONS FINISH LEGEND 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216INTERIOR ELEVATIONS -FOOD PREP A-434A FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 0'2' 4'8' SCALE: 1/4" = 1'-0" FFL 1/4" = 1'-0" Reference: 5 / A-434 1FOOD PREP NORTH ELEVATION Room 123 1/4" = 1'-0" Reference: 5 / A-434 5FOOD PREP EAST ELEVATION B Room 123 1/4" = 1'-0" Reference: 5 / A-434 4FOOD PREP SOUTH ELEVATION Room 123 1/4" = 1'-0" Reference: 5 / A-434 6 FOOD PREP WEST ELEVATION B Room 123 FFL 1/4" = 1'-0" Reference: 1 / A-403 7COURTYARD STO. N. ELEV. Room 141 1/4" = 1'-0" Reference: 1 / A-403 8CTYD STO. E. ELEV. Room 141 1/4" = 1'-0" Reference: 1 / A-403 9COURTYARD STO. S. ELEV. Room 141 1/4" = 1'-0" Reference: 1 / A-403 10 CTYD STO. W. ELEV. Room 141 1/4" = 1'-0" Reference: 5 / A-434 3 FOOD PREP WEST ELEVATION A Room 123 1/4" = 1'-0" Reference: 5 / A-434 2FOOD PREP EAST ELEVATION A Room 123 FFL FURNISHING SCHEDULE GUESTROOM FURNISHINGS GR-307 NIGHTSTAND - SMALL GR-308 NIGHTSTAND - REGULAR GR-319 CLOSET - EFFICIENCY SUITE GR-325 VANITY - EFFICIENCY SUITE GR-501 ART- EFFICIENCY SUITE BED GR-506 MIRROR - LIGHTED BATHROOM VANITY PUBLIC AREA FURNISHINGS PA-803 FIRE EXTINGUISHER - K CLASS - 2.5 GAL KITCHEN EQUIPMENT K-01 WIRE SHELVING - 24"X60" WITH FEET K-02 KEG COOLER POWER PACK K-04 WIRE SHELVING - 24" X 60" WITH LOCKING CAGEAND CASTERS K-05 BAR BACK COOLER K-07 WALK IN REFRIGERATOR K-10 WIRE SHELVING - 24" X 36" WITH CASTERS K-11 WIRE SHELVING - 24" X 30" WITH CASTERS K-13 FAUCET WITH WALL BRACKET K-14 MOP SINK CABINET K-15 WIRE SHELVING - 24" X 48" WITH CASTERS K-16 3 COMPARTMENT SINK WITH WORK TABLE ANDDRYING AREA K-17 STAINLESS STEEL WALL SHELVES K-18 FLOOR TROUGH - 48" X 12" K-19 PRERINSE SPRING WITH WALL BRACKET ANDFAUCET K-20 DISPOSER K-22 UNDERCOUNTER DISHWASHER K-25 HAND SINK WITH SPLASH GUARDS K-26 ICE MAKER - CUBELET K-27 ICE STORAGE BIN K-28 FLOOR TROUGH - 24" X 12" K-31 REFRIGERATED DRAWERS AND WORKTOP K-32 2-CARAFE COMMERCIAL COFFEE MAKER K-33 STAINLESS STEEL WALL SHELVES K-36 STAINLESS STEEL WALL SHELVES K-39 WORK TABLE W/ PREP SINKS K-40 STAINLESS STEEL WALL SHELVES K-41 REACH IN FREEZER- 3 DOOR K-42 ELECTRIC CONVECTION OVEN - FULL SIZE SHEETPAN K-43 ELECTRIC PROOFER AND HOLDING CABINET -FULL SIZE SHEET PAN K-45 WORK TABLE WITH PREP SINK K-47 PASTA COOKER - 2.5 GAL K-49 INDUCTION RANGE, COUNTERTOP K-50 COMMERCIAL MICROWAVE K-51 CLASS 1 KITCHEN HOOD PLUMBING/MECHANICAL FIXTURES PF-01 TOILET - GUESTROOM PF-07 LAVATORY - UNDERMOUNT, 20" X 14" PF-15 FAUCET - LAVATORY TOILET ACCESSORIES HD-04 WALL-MOUNTED ROBE HOOK HD-21 BULK AMENITY DISPENSER AT LAVATORIES EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV REVISION SCHEDULE # DESCRIPTION DATE 2 ADDENDUM 2 6/21/2024 KEYNOTES - ENLARGED 1 2-WAY AREA OF REFUGE COMMUNICATION WITH FRONTDESK. 2 CARD READER TO CALL SERVICE ELEVATOR 3 CALL BUTTONS WITH LOCK PER AHJ REQUIREMENTS. 4 ELEVATOR INDICATORS 5 AFTER-HOURS ACCESS INTERCOM- CONNECTED TO FRONTDESK. 6 KITCHEN HOOD VENT. GC TO SUPPLY AND INSTALL HOOD,MAU-01 AND EF-03 (SEE MECHANICAL). 7 FRP PANELS ON WALLS TO BE SEALED AT ALL SEAMS.ENSURE ALL SEAMS BETWEEN DIFFERING MATERIALS AREBACKED AND SEALED IN ORDER TO MAINTAIN A SANITARY,WASHABLE ENVIRONMENT. 8 CLEAR TEMPERED, PLATED MIRROR 9 FLAT SCREEN TV. 10 PROVIDE ARTICULATING ARM FOR WALL-MOUNTED TV. 11 PROVIDE FULL SUITES OF DATA/VIDEO/POWER UNDER ANDBEWTEEN THE WINDOWS ALONG ALL WALLS. 12 MACHINES TO BE SET UP FOR CARD ACCESS ONLY.COORDINATE POWER AND DATA WITH SUPPLIER. 13 USE CORNER GUARDS ON ALL SURFACES FINISHED WITHWALL COVERING IN PUBLIC AREAS. 14 BOX IN AROUND TOP OF WALK-IN REFRIGERATOR 2 2 2 DDDDWWWW56.1 B 28' - 10 1/2"10' - 8 3/4"26' - 7 1/4"19' - 1 1/4"7' - 1"4' - 9 3/4"6' - 0 3/4"9' - 6 3/4"12' - 6 1/2"16' - 4 1/2"6' - 11 1/4"12' - 6"5' - 0" 801 SF FITNESS 114 257 SF LAUNDRYLOUNGE 112 50 SF EMP RR ADA 110A 30 SF EMP RR 110B 432 SF EMPLOYEEROOM 110 A-4356 A-43513 A-4358 10 11 12 1 2 5 3 4 7 361 SF WATERHEATER & FIRE 108 A-436 9 A-4434 1 2 3 Fire Sprinkler Riser8.1 94 A 14' - 9"14' - 4"25' - 2"0' - 9"10' - 8 1/4" 786 D-108A D-108 D-110D-112D-114 9' - 10 1/4"9' - 7 1/4"5' - 5 1/4" 5' - 4 1/4" 3' - 9"4' - 4"2' - 0"3' - 2 3/4"0' - 9 1/4"6' - 7"5' - 8"W-AW-BW-B6' - 11 1/2"W-BW-B W-B 0' - 9 1/4"6' - 2"6' - 1 1/2"3' - 9 1/4" D-110B D-110A 4' - 0 1/4"7' - 6"7' - 7"W-B W-B W-B A-7035 A-705 2 6 WC-14 WC-14 RB-11 WC-14 RB-10 6 PT-14 W-A RB-10 PA-403 TYP PA-113 TYP PA-312 WC-14WC-14 RB-11 9 10 8.18 WC-13 CW-K D-114 RB-11RB-11 PC-04 PA-114 PA-401 0' - 4"1' - 2 1/4"1' - 6"5' - 0" 8 4' - 0"4' - 0"4' - 0" 12' - 0" B PT-14 PT-14 RB-11 W-BW-BW-B RB-11 PA-401PA-401PA-401PA-401 EQEQ 4' - 0"0' - 6"8' - 0"8 11' - 6"10' - 0"11TYP. 8.18PT-14PT-14 RB-11RB-11 W-BW-BW-BW-B PA-401PA-401PA-401PA-401PA-401 11TYP. B RB-11RB-11 2' - 10 3/4"5' - 0" WC-13 WC-13WC-13 5' - 0"2' - 7"7' - 0"PA-401 PA-114PF-45 WC-13 9 A-703 8 A-703 7 A-703 Typ 3' - 10"4' - 2"0' - 5"0' - 5" PA-508 WC-13 910 CT-10.1 WC-14 PF-36 PF-36 PF-36 PF-36 2' - 7 1/2"2' - 10"3' - 6" 0' - 2 1/2" TYP. 4' - 10 1/2"4' - 10 1/2" 10' - 4 1/2" PL-01 12 12 12 12 EQ EQ 5' - 6"PA-503 7 A-705 3 A-705 6.1PT-14 W-B CT-10.1 PA-401 PF-36 PF-35 WC-14 WC-14 CT-10.1 PF-35PF-35PF-35PF-35 10' - 4 1/2" 4' - 10 1/2"4' - 10 1/4"3' - 9 1/2"4' - 0"PL-01 PL-01 CT-10.1 PA-401 12 121212 6.1 CW-K D-112 WC-14 CT-10.1 9 10 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216ENLARGED PLAN ANDINTERIOR ELEVATIONS -EMPLOYEE, FITNESS &LAUNDRY LOUNGE A-435 FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 0'2' 4'8' SCALE: 1/4" = 1'-0" 1/4" = 1'-0" Reference: 1 / A-121 9PUBLIC AND BOH ENLARGED PLAN Fitness, Laundry Lounge, Employee Room, and Water Heater & Fire 1/4" = 1'-0" Reference: 9 / A-435 3 EMPLOYEE EAST ELEV. Room 110 1/4" = 1'-0" Reference: 9 / A-435 4 EMPLOYEE SOUTH ELEV. Room 110 1/4" = 1'-0" Reference: 9 / A-435 7 EMPLOYEE WEST ELEV. Room 110 1/4" = 1'-0" Reference: 9 / A-435 8 EMPLOYEE NORTH ELEV. Room 110 1/4" = 1'-0" Reference: 1 / A-431 6FITNESS NORTH ELEVATION Room 114 1/4" = 1'-0" Reference: 9 / A-435 1FITNESS EAST ELEVATION Room 114 1/4" = 1'-0" Reference: 1 / A-431 2FITNESS SOUTH ELEVATION Room 114 1/4" = 1'-0" Reference: 9 / A-435 5FITNESS WEST ELEVATION Room 114 1/4" = 1'-0" Reference: 9 / A-435 13 LAUNDRY LOUNGE S. ELEVATION Room 114 1/4" = 1'-0" Reference: 9 / A-435 12 LAUNDRY LOUNGE W. ELEV. Room 114 1/4" = 1'-0" Reference: 9 / A-435 11 LAUNDRY LOUNGE N. ELEVATION Room 114 1/4" = 1'-0" Reference: 9 / A-435 10 LAUNDRY LOUNGE E. ELEV. Room 114 FURNISHING SCHEDULE GUESTROOM FURNISHINGS GR-901 GUESTROOM DISHWASHER GR-906GR-911 TELEVISION & TELEVISION MOUNT PUBLIC AREA FURNISHINGS PA-101 CHAIR - BANQUETTE PA-113 CHAIR - BREAKROOM PA-114 BENCH - FITNESS PA-203 PENDANT LIGHT - PUBLIC RESTROOM PA-308 TABLE - LAUNDRY LOUNGE SIDE TABLE PA-312 TABLE - BREAKROOM TABLE PA-401 ROLLER SHADE - PUBLIC/BOH -MANUAL, SHEER, WALL MOUNT, 5' W PA-403 ROLLER SHADE - PUBLIC/BOH -MANUAL, SHEER/BLACK-OUT, WALLMOUNT, 8' W PA-503 ART - LAUNDRY LOUNGE PA-506 MIRROR - PUBLIC RESTROOM VANITY PA-508 WALL-MOUNTED ROBE HOOK PA-901 EMPLOYEE ROOM REFRIGERATOR OWNER SPECIFIED - OWNER FURNISHED OP-703 LAUNDRY CART OP-705 FIRE EXTINGUISHER - ABC - 10 LBS OP-706 FIRE EXTINGUISHER CABINET PLUMBING/MECHANICAL FIXTURES PF-02 TOILET - PUBLIC WALL MOUNT WITHFLUSHOMETER PF-30 EYEWASH STATION PF-31 SINK - BOH LAUNDRY PF-35 LAUNDRY LOUNGE DRYER PF-36 LAUNDRY LOUNGE WASHING MACHINE PF-43 SINK - EMPLOYEE RESTROOMS PF-45 REFRIGERATED BOTTLE FILLER (CUPSPROVIDED) PUBLIC AREA FURNISHINGS HD-25 PUBLIC AND STAFF RESTROOM GRABBARS KEYNOTES - ENLARGED 1 2-WAY AREA OF REFUGE COMMUNICATION WITHFRONT DESK. 2 CARD READER TO CALL SERVICE ELEVATOR 3 CALL BUTTONS WITH LOCK PER AHJREQUIREMENTS. 4 ELEVATOR INDICATORS 5 AFTER-HOURS ACCESS INTERCOM-CONNECTED TO FRONT DESK. 6 KITCHEN HOOD VENT 7 FRP PANELS ON WALLS TO BE WELDED AT ALLSEAMS. ENSURE ALL SEAMS BETWEENDIFFERING MATERIALS ARE BACKED ANDSEALED IN ORDER TO MAINTAIN A SANITARY,WASHABLE ENVIRONMENT. 8 CLEAR TEMPERED, PLATED MIRROR 9 FLAT SCREEN TV. 10 PROVIDE ARTICULATING ARM FORWALL-MOUNTED TV. 11 PROVIDE FULL SUITES OF DATA/VIDEO/POWERUNDER AND BEWTEEN THE WINDOWS ALONGALL WALLS. 12 MACHINES TO BE SET UP FOR CARD ACCESSONLY. COORDINATE POWER AND DATA WITHSUPPLIER. 13 USE CORNER GUARDS ON ALL SURFACESFINISHED WITH WALL COVERING IN PUBLICAREAS. EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV Revision Schedule Number Description Date 6.1 CT-15 WC-15 CT-11 PF-43 PF-02 HD-25 6.1 CT-15 WC-15 CT-15 WC-15 D-110A PT-11 PL-11 6.1 CT-15 WC-15 PF-02 PF-43 CT-11 PF-02 PF-43 6.1 CT-15 WC-15 WC-15 PF-43 D-110B CT-15 WC-15 PT-11 PL-11 6.1 B A-436 6 A-4363 5 8 7 2 1 4 50 SF EMP RR ADA 110A 30 SF EMP RR 110B D-110B D-110A PF-02 HD-25 PF-43 PF-02PF-43 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216INTERIOR ELEVATIONS -EMPLOYEE RESTROOM A-436 FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 0'1' 2'4' SCALE: 1/2" = 1'-0" 1/2" = 1'-0" Reference: 9 / A-436 5ADA EMPLOYEE RR E. ELEV. Room 110A 1/2" = 1'-0" Reference: 9 / A-436 6ADA EMPLOYEE RR S. ELEV. Room 110A 1/2" = 1'-0" Reference: 9 / A-436 7ADA EMPLOYEE RR W. ELEV. Room 110A 1/2" = 1'-0" Reference: 9 / A-436 8 ADA EMPLOYEE RR N. ELEV. Room 110A 1/2" = 1'-0" Reference: 9 / A-436 3EMPLOYEE RESTROOM W. ELEV. Room 110B 1/2" = 1'-0" Reference: 9 / A-436 4EMPLOYEE RESTROOM N. ELEV. Room 110B 1/2" = 1'-0" Reference: 9 / A-436 1EMPLOYEE RESTROOM E. ELEV. Room 110B 1/2" = 1'-0" Reference: 9 / A-436 2EMPLOYEE RESTROOM S. ELEV. Room 110B 1/2" = 1'-0" Reference: 9 / A-435 9 EMPLOYEE RESTROOM PLANS EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV Revision Schedule Number Description Date A-433 A-437 2 3 5 6 A-438 4 1 25 D-116 D-115 P1.1 P8 P7 P8 XE3P8P8 P3.1 P3.3 P1.1 P1.2 P8 A-4377 A-43863 4 171 SF MEN'SRESTROOM 116 172 SF WOMEN'S RESTROOM 115 P8 9' - 0 1/4"5' - 2"8' - 11 3/4"6' - 11" 2' - 4 3/4"3' - 4 3/4"1' - 6" 2' - 8 3/4"3' - 9"2' - 8 3/4"2' - 1"4' - 10 3/4"2' - 1"1' - 7 1/4"1' - 6" 1' - 6" 1' - 8 3/4"5' - 1"5' - 1" 2' - 1 1/2"3' - 0"3' - 6"5' - 1 3/4"3' - 2"3' - 0 3/4" 1' - 6 1/4" 2' - 8 3/4"3' - 9"2' - 8 3/4"2' - 1"4' - 10 3/4" 2' - 5 1/2"2' - 1"2' - 1 1/2"2' - 1 1/2"3' - 10"5' - 1"1' - 0"5' - 1"3' - 11 1/2"2' - 1"2' - 5 1/2" CT-10 CT-10 CT-10 CT-11 WC-15WC-15 WC-15 WC-15 PL-01 PA-506PA-506 HD-13 EQEQ 2' - 10"5' - 2"EQEQ FREE STANDING TRASH RECEPTACLE PL-01 SS-01 2' - 10"2' - 8 3/4"2' - 8 3/4"2' - 5 1/2"SS-01 PA-502 PA-203PA-203 P3.3 PA-507 PA-203WC-15 WC-15 PL-01 EQEQ PA-506 1' - 0"1' - 0"CT-11 8' - 0"C WC-15 WC-15CT-10.1 WC-15 1' - 0"8' - 0"CT-11 D-116 PT-11 8.1 WC-15 PA-203 PA-506 PL-011' - 0"8' - 0"2' - 10"CT-11 8.1 WC-15 CT-10.1 WC-15 2' - 10"PA-507 WC-15 3' - 10"1' - 0"737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216INTERIOR ELEVATIONS -PUBLIC RESTROOMPLAN AND INTERIORELEVATIONS A-437 FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 1/2" = 1'-0" Reference: 1 / A-431 1Lobby Restroom Enlarged Plan 1/2" = 1'-0"2Lobby Restroom Men's Elevation A 1/2" = 1'-0"3Lobby Restroom Men's Elevation B 1/2" = 1'-0"5Lobby Restroom Men's Elevation C 1/2" = 1'-0"6Lobby Restroom Men's Elevation D 1/2" = 1'-0"7 Lobby Restroom Men's Elevation D1 1/2" = 1'-0"4 Lobby Restroom Men's Elevation B1 KEYNOTES - UNIT BATHROOMS A 2 CM ENGINEERED STONE COUNTERTOP SURFACE, STRAIGHTPROFILE WITH EASED EDGE B 2 CM ENGINEERED STONE BACK SPLASH TO MATCH COUNTER TOP2 CM ENGINEERED STONE BACK SPLASH TO MATCH COUNTER TOP C LAMINATE OVER 3/4" PLYWOOD 0'1' 2'4' SCALE: 1/2" = 1'-0" EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV Revision Schedule Number Description Date 1' - 0"8' - 0"WC-15WC-15 CT-10.1 CT-11 D-115 PT-111' - 0"8' - 0"PA-507 PA-203 PA-506 PL-01 2' - 10"CT-10.1 CT-11WC-15 PA-506 PA-506 HD-13 2' - 8 3/4"2' - 8 3/4"2' - 10"TO REFLECTIVE SURFACE3'-4" MAX.EQEQ 5' - 2"EQ EQ 2' - 10"PT-14 PT-14 PL-01 SS-01 PA-203 PT-14 CT-10.1FREE STANDING TRASH RECEPTACLE PT-14 PA-502 CT-11 1' - 0"8' - 0"WC-15 PA-203 2' - 10"PL-01 WC-15 CT-10.1 WC-15 WC-15 CT-10.1 SS-01 PL-01 WC-152' - 10"CT-10.1 WC-15 4' - 9"3' - 10 1/2"4' - 6"PA-507 3' - 4" 4' - 6" MIN. 3' - 6"TOILET SEAT HEIGHT1 ' - 5" - 1' - 7"REQ'D CLEAR1' - 0"REQ'D CLEAR0' - 1 1/2"GRIPPING SURFACE2'-9" - 2'-0"MIN. 3' - 0"1'-6" MIN.3'-3" - 3'-5"1' - 5" 3' - 5" GRAB BAR(TOILET / 2-WALL AND VERTICAL)SURFACE MOUNTED HD 06 NOTE: TYP. CLEAR AREA AROUND GRAB BARS TO BE : ABOVE - 1'-0", BELOW - 1'-5" . BETWEEN, SHOWER CONTROLS, SHOWER FITTING, AND OTHER GRAB BARS A CLEAR DISTANCE OF 1.5" IS PERMITTED. MIN. 1' - 0" MIN. 2' - 0"ACC.3' - 4"U.O.N.5' - 0"ROBE HOOKSURFACE MTD. HD 12INSTALL BOTH ACC. AND NON ACC. COAT HOOK IN ACC. PUBLIC EMPLOYEE BATHAUTOMATIC PAPER TOWER DISPENSER HD 13TO SHEET OR TOP OF CONTROL4' - 0"NOTE: MUST NOT PROJECT MORE THAN 4" INTO ACCESSIBLE ROUTE TO OPERABLE PART3' - 10" MAX.NOTE: PROVIDE OVER HANDWASH SINK IN FOOD PREP PROVIDE ADEQUATE CLEARANCE FROM FAUCET AND SINK PAPER TOWEL /SOAP DISPENSERRECESSED HD 173'6" - 3'-10" MAX.RECESSED WASTERECEPTACLEPOOL RESTROOMS HD 19 NOTE: MUST NOT PROJECT MORE THAN 4" INTO ACCESSIBLE ROUTE TO TRIM17" MAXURINAL WALL MOUNTED HD 221'-9" MINNOTE: PROVIDE WOOD BLOCKING FOR ALL TOILET ACCESSORIES MOUNTED IN GYP. BD. PARTITIONS. MAINTAIN INTEGRITY OF FIRE RATING WHERE ACCESSORIES ARE IN RATED WALLS. REVIEW AND CONFIRM LOCAL CODES FOR ADDITIONAL ADA REQUIREMENTS. TOILET TISSUE DISPENSER HD 03 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216INTERIOR ELEVATIONS -PUBLIC RESTROOMRCP AND INTERIORELEVATIONS A-438 FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 1/2" = 1'-0" Reference: 1 / A-437 1Lobby Restroom Women's Elevation A 1/2" = 1'-0" Reference: 1 / A-437 2Lobby Restroom Women's Elevation B 1/2" = 1'-0" Reference: 1 / A-437 4 Lobby Restroom Women's Elevation C 1/2" = 1'-0" Reference: 1 / A-437 5 Lobby Restroom Women's Elevation D 1/2" = 1'-0" Reference: 1 / A-437 6 Lobby Restroom Women's Elevation D1 1/2" = 1'-0"3 Lobby Restroom Women's Elevation B1 A B C AB C KEYNOTES - UNIT BATHROOMS A 2 CM ENGINEERED STONE COUNTERTOP SURFACE, STRAIGHTPROFILE WITH EASED EDGE B 2 CM ENGINEERED STONE BACK SPLASH TO MATCH COUNTER TOP2 CM ENGINEERED STONE BACK SPLASH TO MATCH COUNTER TOP C LAMINATE OVER 3/4" PLYWOOD 0'1' 2'4' SCALE: 1/2" = 1'-0" 3/4" = 1'-0" PUBLIC TOILET ACCESSORIES LEGEND EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV Revision Schedule Number Description Date RB-10 PT-11PL-11 PT-03PT-03 RB-10 OP-705D-105 D-109 PL-11 PT-11 PL-11PT-11 56.146 PT-03 RB-10 PT-03 RB-10 PT-03 RB-10 PT-03 4 PT-03 RB-10 PT-03 RB-10 PL-11 PT-03 D-105A PT-03 PT-03 RB-10 PT-03 RB-10 6.1 PT-03 RB-10 PL-11 PT-11 PT-03 D-109 RB-10 PT-03 5 6 PT-03 RB-10 RB-10 56 RB-11 546 RB-10 OPEN TO BOH DRYERS D-107 PT-03PT-03PT-03PT-03 56.1 C 85 SF LINENSTORAGE 109 56 SF HOUSEKEEPINGOFFICE 109A 68 SF ELEV 1 111 64 SF ELEV 2 113 13 SF LINEN CHUTE 140 131 SF LINEN DISCHARGE &SORTING 107 84 SF BOH DRYERS 105A 750 SF BOH LAUNDRY 105 3' - 4 1/2" 39' - 7 1/4"10' - 10"13' - 0 3/4"50' - 10"25' - 1 1/4"A-442 1 5 26 A-442 11 1210 A-44213 14 15 16 A-442 3 4 7 8 4 A-503 1 76 0' - 4" 12' - 2 1/4"2' - 0"2' - 0 1/2"D-105 D-109 D-107 7' - 0"0' - 7 1/4" D-105A 7' - 8 1/4"5' - 1 1/2"8' - 11 3/4"737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216ENLARGED BOH PLAN &INTERIOR ELEVATIONS A-442 FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 0'2' 4'8' SCALE: 1/4" = 1'-0" 1/4" = 1'-0" Reference: 1 / A-121 9BOH FLOOR PLAN - LAUNDRY 1/4" = 1'-0" Reference: 9 / A-442 1BOH LAUNDRY ELEVATION A Room 105 1/4" = 1'-0" Reference: 9 / A-442 2BOH LAUNDRY ELEVATION B Room 105 1/4" = 1'-0" Reference: 9 / A-442 5BOH LAUNDRY ELEVATION C Room 105 1/4" = 1'-0" Reference: 9 / A-442 6BOH LAUNDRY ELEVATION D Room 105 1/4" = 1'-0" Reference: 9 / A-442 11 BOH DRYER ELEVATION A Room 105A 1/4" = 1'-0" Reference: 9 / A-442 10 BOH DRYER ELEVATION B Room 105A 1/4" = 1'-0" Reference: 9 / A-442 12 BOH DRYER ELEVATION D Room 105A 1/4" = 1'-0" Reference: 1 / A-403 13 LINEN DISCHARGE ELEVATION A Room 107 1/4" = 1'-0" Reference: 9 / A-442 14 LINEN DISCHARGE ELEVATION B Room 107 1/4" = 1'-0" Reference: 1 / A-403 15 LINEN DISCHARGE ELEVATION C Room 107 1/4" = 1'-0" Reference: 9 / A-442 16 LINEN DISCHARGE ELEVATION D Room 107 1/4" = 1'-0" Reference: 9 / A-442 3 HSK OFFICE/LINEN STO. ELEV. A Room 109, 109A 1/4" = 1'-0" Reference: 9 / A-442 4 HSK OFFICE/LINEN STO. ELEV. B Room 109, 109A 1/4" = 1'-0" Reference: 9 / A-442 7 HSK OFFICE/LINEN STO. ELEV. C Room 109, 109A 1/4" = 1'-0" Reference: 9 / A-442 8 HSK OFFICE/LINEN STO. ELEV. D Room 109, 109A EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV Revision Schedule Number Description Date 5 WC-16 RB-11 PT-15 RB-10 5 RB-10 D-108A PT-15 6" Standpipe4" Main Floor Sprinklers4" Dry SystemNitrogen Wall Mount System 1' - 10"2' - 2 1/2"1' - 6"WC-16 RB-11 3 3 K D-128 K WC-16 WC-16 RB-11 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216BOH INTERIORELEVATIONS A-443 FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 0'1' 2'4' SCALE: 1/2" = 1'-0" 1/4" = 1'-0" Reference: 9 / A-435 1Electrical / Fire Elevation A Room 108 1/4" = 1'-0" Reference: 9 / A-435 2Electrical / Fire Elevation B Room 108 1/4" = 1'-0" Reference: 9 / A-435 3Electrical / Fire Elevation C Room 108 1/4" = 1'-0" Reference: 9 / A-435 4 Electrical / Fire Elevation D Room 108 1/4" = 1'-0" Reference: 1 / A-403 8 Water Heaters Elevation D Room 104 1/4" = 1'-0" Reference: 9 / A-442 5Water Heaters Elevation A Room 104 1/4" = 1'-0" Reference: 1 / A-403 6Water Heaters Elevation B Room 104 1/4" = 1'-0" Reference: 9 / A-442 7Water Heaters Elevation C Room 104 1/4" = 1'-0" Reference: 5 / A-434 9Electrical Elevation A Room 128 1/4" = 1'-0" Reference: 1 / A-407 10Electrical Elevation B Room 128 1/4" = 1'-0" Reference: 5 / A-434 11Electrical Elevation C Room 128 1/4" = 1'-0" Reference: 1 / A-407 12Electrical Elevation D Room 128 EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV Revision Schedule Number Description Date 3 3.1 2.1 DCB 1 A-443 8 5 6 7 A-4471 A-446 5 7 68 1.1 A A-446 1 2 3 4 2 6' - 8 1/4"27' - 0"5' - 1 1/2"2' - 2"5' - 1 1/2"16' - 0"2' - 6"2' - 2"4' - 6 1/4"2' - 11 1/2"2' - 2"16' - 8"2' - 2"1' - 11 1/2" 2' - 6" 7' - 1 1/2"4' - 1 1/2"4' - 1 1/2" R 3 ' - 0 "R 3' - 0"R 3 ' - 0 "R 3' - 0"5' - 8 1/4"Pool 432 SF Splash Pad272 SF 2,152 SF POOL &SPLASH PAD 101 80 SF POOLRESTROOM 102 Pool Deck1,458 SF 204 SF POOL MEP 103 548 SF ELECTRICAL 104 711 SF PUBLIC CORRIDOR 10043 SF VESTIBULE 100A0' - 4 1/2"36"x48"Clear Space 5' - 1 1/4"2' - 5 1/2"9' - 10"1' - 3"9' - 10"1' - 3"9' - 10"1' - 3"9' - 10"1' - 3"9' - 10"2' - 5 1/2"0' - 11 1/4" CW-GCW-GCW-GCW-GCW-G CW-F CW-F D-101 CW-L D-103 D-102 D-101A D-104D-100A CW-F CW-F CW-F 0' - 6 3/4"4' - 0 1/2"2' - 3 1/4"5' - 0"3' - 6"5' - 0"3' - 6"5' - 0"1' - 6 1/4"4' - 3"0' - 4"3' - 4"7' - 0 1/2"12' - 4"10' - 5 1/4"5' - 0 1/4" 2' - 4"0' - 11 3/4"5' - 1"3' - 5"5' - 0"3' - 6"5' - 0"4' - 3"11' - 4"4' - 1"5' - 0"CW-F 10' - 10" 16' - 0" D-104A16' - 8"W-EW-DW-E D-100 CW-HCW-H 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216ENLARGED PLAN -POOL, SPLASH PAD,RESTROOM & MEP ANDELECTRICAL A-444 FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 0'2' 4'8' SCALE: 1/4" = 1'-0" 1/4" = 1'-0" Reference: 1 / A-121 1 ENLARGED INDOOR POOL AND SPLASH PAD CONSTRUCTIONPLAN EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV Revision Schedule Number Description Date 3 3.1 2.1 DCB 1 A-443 8 5 6 7 A-446 5 7 68 1.1 A A-446 1 2 3 4 2 2' - 2"4' - 6 3/4"4' - 1 1/2" 2,152 SF POOL &SPLASH PAD 101 80 SF POOLRESTROOM 102 Pool Deck1,458 SF 204 SF POOL MEP 103 548 SF ELECTRICAL 104 711 SF PUBLIC CORRIDOR 100 43 SF VESTIBULE 100A 5' - 1 1/4"2' - 5 1/2"9' - 10"1' - 3"9' - 10"1' - 3"9' - 10"1' - 3"9' - 10"1' - 3"9' - 10"2' - 5 1/2"0' - 11 1/4" CW-GCW-GCW-GCW-GCW-G CW-F CW-F D-101 CW-L D-103 D-102 D-101A D-104D-100A CW-F CW-F CW-F 0' - 6 3/4"4' - 0 1/2"2' - 3 1/4"5' - 0"3' - 6"5' - 0"3' - 6"5' - 0"1' - 6 1/4"4' - 3"0' - 4"3' - 4"12' - 4"10' - 5 1/4"5' - 0 1/4" 2' - 4"0' - 11 3/4"5' - 1"3' - 5"5' - 0"3' - 6"5' - 0"4' - 3"11' - 4"4' - 1"5' - 0"CW-F 10' - 10" 16' - 0" D-104A 36"x48"Clear Space Aqua Shoot 3 Aqua Shroom 5Aqua Drop, 24" D, Radial Aqua Drop, 24" D, Directional Aqua Drop, 24" D, Radial Aqua Bubbler, Typ Splash Zone, Typ Potential Location for Activation Button?Can it be wall-mounted?5' - 0"5' - 0"5' - 1 1/2"5' - 0"4' - 1 1/2"5' - 0"5' - 0"OF-712OF-712OF-705OF-705 OF-708OF-702 OF-706 OF-702 OF-702 OF-706 OF-706 OF-702 OF-708 OF-702 OF-708 OF-702 OF-706 OF-702 ? 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216ENLARGED FFE PLAN-POOL, SPLASH PAD,RESTROOM & MEP ANDELECTRICAL A-445 FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 0'2' 4'8' SCALE: 1/4" = 1'-0" 1/4" = 1'-0"1Enlarged Indoor Pool and Splash Pad Plan FFE Plan EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV Revision Schedule Number Description Date CB SWIMMING POOLSPLASH PAD 2.11.1 2 CT-16CT-15 CT-15 CB 2.1 1.12 DD 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216INTERIOR ELEVATIONS -POOL & SPLASH PAD A-446 FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 FFL FFL 1/4" = 1'-0"1Pool and Spash Pad Elevation A 1/4" = 1'-0"2 Pool and Spash Pad Elevation B 1/4" = 1'-0"3Pool and Spash Pad Elevation C 1/4" = 1'-0"4 Pool and Spash Pad Elevation D FFL 1/4" = 1'-0"5Pool MEP Elevation A 1/4" = 1'-0"6Pool MEP Elevation B 1/4" = 1'-0"7Pool MEP Elevation C 1/4" = 1'-0"8 Pool MEP Elevation D EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV Revision Schedule Number Description Date 2 A-447 2 3 45 A-44767D-102 1' - 11 1/4"1' - 9" 0' - 11 1/4" 2' - 6 1/4" 0' - 4" 2' - 6"4' - 6"0' - 6"1' - 5"3' - 0"3' - 5 1/2" 1' - 0"2' - 4 1/4"8' - 6 1/4"2' - 8"2' - 2" 10' - 0" HD-24 HD-23HD-22HD-15 HD-14.21' - 6 3/4"1' - 5 1/4"2' - 8 1/2"HD-24 HD-14.2 HD-08.1 CT-15 3' - 4"0' - 8"1' - 10"2' - 11"HD-22 PA-518 PF-08 HD-15 HD-23 HD-11.31' - 6"2' - 11 1/2"CT-15 HD-11.2HD-22 HD-24 PF-02 CT-15 HD-15 PA-518 HD-24 EQ EQ HD-11.2 PF-12 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216ENLARGED POOLRESTROOM DRAWINGS A-447 FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 0'1' 2'4' SCALE: 1/2" = 1'-0" 1/2" = 1'-0" Reference: 1 / A-444 1Pool Restroom Room 102 1/2" = 1'-0" Reference: 1 / A-447 2Pool Restroom Elevation A Room 102 1/2" = 1'-0" Reference: 1 / A-447 3Pool Restroom Elevation C Room 102 1/2" = 1'-0" Reference: 1 / A-447 4Pool Restroom Elevation B Room 102 1/2" = 1'-0" Reference: 1 / A-447 5Pool Restroom Elevation D Room 102 1/2" = 1'-0" Reference: 1 / A-447 6 Pool Shower Elevation B1 Room 102 1/2" = 1'-0" Reference: 1 / A-447 7 Pool Shower Elevation D1 Room 102 EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV Revision Schedule Number Description Date 5 C 4 255 SF ENGINEERINGOFFICE &STORAGE 207 98 SF PBX/MDF 207A A-448 2 4 53 A-448 6 10 9 7 8' - 6 1/4"6' - 2 1/2"25' - 5 1/4" 11' - 9 1/4"13' - 8" 3' - 6" 2' - 2 1/2" D-207A D-207 D-207B 0' - 4 1/2"0' - 2 1/2"5 6.1 C 7 6 497 SF LINENS &HOUSEKEEPING 209 5 SF IDF 209B A-448 11 6 SF DAC 209C 12 13 14 2' - 2 3/4"13' - 6"5' - 4 3/4"2' - 10 1/2"8' - 3 3/4"12' - 11"3' - 9 3/4"3' - 8 1/4"D-207 D-X09B D-X09C D-X09 2' - 6 3/4"1' - 2" WC-16 RB-11 RB-11 WC-16 WC-16 RB-11 RB-11 PL-11 PT-11 D-207AD-207 WC-16 RB-11 WC-16 PL-11 PT-11 D-207B D-207A PT-11PL-11 D-207 6 3' - 4"D-X09C PT-03 PL-02 STL WC-16 PT-03 PT-03 C.1 6.1 6 D-X09BD-X09 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216ENLARGED PLAN &INTERIOR ELEVATIONS -OFFICE / STORAGE /PBX ROOM A-448 FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 1/4" = 1'-0" Reference: 1 / A-133 1Enlarged Engineering Office / Storage / PBX Floor Plan Rooms 207 & 207A 1/4" = 1'-0" Reference: 1 / A-133 8Enlarged Linens and Housekeeping Plan Room 209 1/4" = 1'-0" Reference: 1 / A-448 2Engineering Office / Sto. Elevation A Room 207A 1/4" = 1'-0" Reference: 1 / A-448 3 Engineering Office / Sto. Elevation B Room 207A 1/4" = 1'-0" Reference: 1 / A-448 4 Engineering Office / Sto. Elevation C Room 207A 1/4" = 1'-0" Reference: 1 / A-448 5Engineering Office / Sto. Elevation D Room 207A FFL FFL FFL FFL 1/4" = 1'-0" Reference: 1 / A-448 6PBX / MDF Elevation A Room 207A 1/4" = 1'-0" Reference: 1 / A-448 7 PBX / MDF Elevation B Room 207A 1/4" = 1'-0" Reference: 1 / A-448 9 PBX / MDF Elevation C Room 207A 1/4" = 1'-0" Reference: 1 / A-448 10 PBX / MDF Elevation D Room 207A 1/4" = 1'-0" Reference: 8 / A-448 11Linens & Housekeeping Elevation A Room X09 1/4" = 1'-0" Reference: 1 / A-448 12 Linens & Housekeeping Elevation B Room X09 1/4" = 1'-0" Reference: 8 / A-448 13Linens & Housekeeping Elevation C Room X09 1/4" = 1'-0" Reference: 1 / A-448 14 Linens & Housekeeping Elevation D Room X09 EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV Revision Schedule Number Description Date ML.1KN P Q 7 8 428 SF GUESTCORRIDOR 139A-450 2 3 4 5 28 SF VESTIBULE 139A 1' - 10 1/4"5' - 9"30' - 2 1/4"14' - 1 3/4"24' - 5 1/4"5' - 7"1' - 11 1/4"2' - 4 1/4" D-128D-X32 5' - 9"7' - 0"7' - 5 1/4" 7' - 10 3/4"0' - 3 3/4" D-139A D-139B 2' - 0"A-450 78 L ELECTRICAL 139B 7' - 0 1/2"9' - 4" 7' - 1 1/2"3' - 7 1/2" 7' - 3 3/4"3' - 10"5' - 2 1/2"5' - 8 1/2"5' - 5 1/4"5' - 11 1/4"D-G01D-G01D-G01 D-G01 D-G01 D-G01 D-G01 D-X15 D-G01 11' - 2 3/4" ML.1NP WC-11WC-10WC-11WC-10WC-11 RB-10 RB-10 WC-10 L WC-10 D-G01D-G01D-G01D-G01 D-G01 PT-11 PL-01PT-11PL-01PT-11PL-01PT-11PL-01PT-11PL-01 OP-706 8 D-139A CW-H WC-10 WC-11 WC-11 RB-10PC-04 ML.1NP WC-10WC-11WC-10WC-11WC-10 RB-10 RB-10 D-X06 WC-10 L D-G01D-X15 D-G01 D-G01D-G01A PL-01PT-11PL-01PT-11PL-15PT-15PL-01PT-11PL-11PT-03 PL-01 PT-11 WC-11 8 WC-10 WC-11 CW-J D-139 WC-11 RB-10 PC-04 FGE A-434A 56 K 7 8 H J 1,746 SF GUESTCORRIDOR 215A-451 1 2 7' - 0"12' - 0 3/4"12' - 0 3/4"7' - 0 1/4"7' - 0"12' - 0 3/4"12' - 0 1/2"7' - 0 1/4"7' - 0 1/4"7' - 10 3/4"0' - 4 3/4"5' - 1" 0' - 7 1/2"5' - 8 1/2"5' - 1 1/4"5' - 8 1/2"5' - 1"5' - 8 1/2"7' - 0 1/4"7' - 0"7' - 0 1/4"7' - 0 1/4"5' - 1"D-G01D-G01D-G01 D-G01 D-G01 D-G01D-G01D-G01 D-G01 D-G01 12' - 0 3/4" D-139B PT-10 RB-10 PC-04 WC-10 D-139A CW-H PC-04 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216ENLARGED PLAN &INTERIOR ELEVATIONS -GUEST CORRIDOREAST WING A-450 FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 1/4" = 1'-0" Reference: 1 / A-122 1L01 GUEST CORRIDOR - EAST WING PLAN FFL 1/4" = 1'-0" Reference: 5 / A-434 2L01 GUEST CORRIDOR - EAST WING - ELEVATION A 1/4" = 1'-0" Reference: 1 / A-450 3 L01 GUEST CORR. - EAST WING ELEV. B FFL 1/4" = 1'-0" Reference: 5 / A-434 4L01 GUEST CORRIDOR - EAST WING ELEVATION C 1/4" = 1'-0" Reference: 1 / A-450 5 L01 GUEST CORR. - EAST WING ELEV. D 1/4" = 1'-0" Reference: 1 / A-134 6L02-L05 GUEST CORRIDOR - EAST WING PLAN - GRID E-K 1/4" = 1'-0" Reference: 1 / A-450 7 L01 GUEST CORR. - EAST WING ELEV. B1 1/4" = 1'-0" Reference: 1 / A-450 8 L01 GUEST CORR. - EAST WING ELEV. D1 0'2' 4'8' SCALE: 1/4" = 1'-0" EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV Revision Schedule Number Description Date FGE KHJ2 A-301 WC-10 RB-10 WC-11WC-10WC-11 WC-10 WC-11 RB-10RB-10 D-G01D-G01D-G01 D-G01 929 PL-01PT-11PL-01PT-11 PL-01PT-11PL-01PT-11PL-01PT-11 FG EKHJ 2 A-301 WC-11WC-10WC-11WC-10 WC-11 WC-10 RB-10RB-10 RB-10 RB-10 OP-706 D-G01D-G01D-G01 D-G01 D-G01 PL-01PT-11PL-01PT-11PL-01PT-11 PL-01 PT-11 PL-01 PT-11 M L.1 KN P Q 7 8 A-451 4 5 6 7 7' - 10 3/4"14' - 1 3/4"7' - 10 1/4"7' - 10 3/4"7' - 0 1/2"7' - 1 1/2"12' - 0 1/4"12' - 3 1/2" D-X32 W-C 12' - 0 1/2"7' - 0 3/4"8' - 4 1/4"2' - 4 3/4"7' - 11"7' - 0 1/4"19' - 1 1/2"12' - 3 1/2"EQEQA-450 78 L 7' - 0 1/4"7' - 1 1/2" 2' - 10 1/4"5' - 8 1/2"5' - 5 1/4"7' - 0 1/2"7' - 1 1/2"5' - 11"D-G01D-G01D-G01 D-G01 D-G01 D-G01 D-X15 D-G015' - 2 1/4"2' - 3 1/4"ELECTRICAL 215A5' - 1 1/4"1' - 1" ML.12 A-302 KN P WC-11WC-10WC-11WC-10 RB-10RB-10RB-10 RB-10 WC-11 L OP-706 D-G01D-G01D-G01D-G01D-G01 OP-706 PL-01 PT-11PL-01 PT-11PL-01PT-11PL-01PT-11PL-01PT-11 8 W-C RB-10 PT-10 WC-11 RB-10 M L.1 2 A-302 KNP PL-15WC-11WC-10 WC-11 RB-10RB-10 D-X32 L D-G01AD-G01D-X15D-G01 D-G01 PL-01PT-11PL-11PT-03 PL-01 PT-11PL-01PT-11PL-01PT-11PT-15 8 OPEN TO BEYOND WC-11 RB-10 WC-11 RB-10 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216ENLARGED PLAN &INTERIOR ELEVATIONS -GUEST CORRIDOREAST WING A-451 FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 FFL FFL 1/4" = 1'-0" Reference: 6 / A-450 1TYP. LEVEL GUEST CORR.- EAST WING GRID E-K- ELEV. A 1/4" = 1'-0" Reference: 6 / A-450 2TYP. LEVEL GUEST CORR.- EAST WING GRID E-K- ELEV. C 1/4" = 1'-0"3TYP. LEVEL GUEST CORR. PLAN- EAST WING GRID K-Q FFL FFL 1/4" = 1'-0" Reference: 6 / A-450 4TYP. LEVEL GUEST CORR.- EAST WING GRID K-Q- ELEV. A 1/4" = 1'-0" Reference: 3 / A-451 5 TYP. LEVEL GUEST CORR.- EAST WING GRID K-Q- ELEV. B 1/4" = 1'-0" Reference: 6 / A-450 6TYP. LEVEL GUEST CORR.- EAST WING GRID K-Q- ELEV. C 1/4" = 1'-0" Reference: 3 / A-451 7 TYP. LEVEL GUEST CORR.- EAST WING GRID K-Q- ELEV. D 0'2' 4'8' SCALE: 1/4" = 1'-0" EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV Revision Schedule Number Description Date FD 5 3 3.1 6.1 C.1 E CB 8.1 4 7 8 6 A-452 2 35 4 A-45279 A-45268 A-452 10 11 2' - 1"5' - 6"5' - 6"5' - 10 3/4" 2' - 0 1/2" W-EW-DW-E D-101A D-100A CW-H D-106 D-108 D-110 D-112 D-1147' - 10 1/4"6' - 10"4' - 1"5' - 2 3/4"0' - 9" 0' - 10 1/4"3' - 8"0' - 3 3/4"5' - 1 1/4" CW-K CW-K 14' - 0"5' - 6 1/2" 1' - 6 1/4"8' - 11 3/4"8' - 7" 1' - 7 1/2" 5' - 0"5' - 2 1/4"B W-EW-DW-E WC-10WC-10 WC-11 RB-10 RB-10 RB-10 D-101A PC-04 3.1 D-104A PL-11PT-11 B OPEN TO CORRIDOR WC-10 WC-10 RB-10 RB-10 CW-HD-100A WC-10 PC-04 D-100ACW-H WC-10 PC-04 D-100CW-H PT-10 PC-04 53.1 6.11 A-3014 76 OPEN TO CORRIDORD-104A RB-10 WC-10 PL-11PT-11 5 3.16.1 1 A-301 476 OPEN TO CORRIDOR WC-10 WC-11 WC-10 WC-10 D-114 D-112 CW-K CW-K RB-10 RB-10 D-110 PL-11 PT-11 D-108 D-106 PL-11 PT-11 PT-03PL-11PC-04PC-04 OP-706 PT-10 C.1 ECB 1 A-302 OPEN TO ELEVATOR LOBBY OPEN TO CORRIDOR WC-10 WC-11 WC-10 RB-10 RB-10 D-105 WC-12PL-11PT-11 C.1E C BWC-10 WC-10 RB-10 OPEN TO GUEST STO. OP-706 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216ENLARGED PLAN &INTERIOR ELEVATIONS -GUEST CORRIDORWEST WING A-452 FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 1/4" = 1'-0" Reference: 1 / A-121 1L01 ENLARGED GUEST CORRIDOR PLAN - WEST WING 1/4" = 1'-0" Reference: 1 / A-452 2L01 GUEST CORRIDOR - WEST WING - ELEVATION A 1/4" = 1'-0" Reference: 1 / A-452 3 L01 GUEST CORR. - WEST WING - ELEV. B 1/4" = 1'-0" Reference: 1 / A-452 4 L01 GUEST CORRIDOR - WEST WING - ELEVATION C 1/4" = 1'-0" Reference: 1 / A-452 5L01 GUEST CORR. - WEST WING - ELEV. D 1/4" = 1'-0" Reference: 1 / A-452 7L01 GUEST CORR. - WEST WING - ELEV. F 1/4" = 1'-0" Reference: 1 / A-452 9L01 GUEST CORRIDOR - WEST WING - ELEVATION H 1/4" = 1'-0" Reference: 1 / A-444 6 L01 GUEST CORRIDOR - WEST WING - ELEVATION E 1/4" = 1'-0" Reference: 1 / A-444 8 L01 GUEST CORRIDOR - WEST WING - ELEVATION G 1/4" = 1'-0" Reference: 9 / A-435 10 L01 GUEST CORRIDOR - WEST WING - ELEVATION J 1/4" = 1'-0" Reference: 9 / A-435 11 L01 GUEST CORRIDOR - WEST WING - ELEVATION K FFL FFL FFL FFL FFL 0'2' 4'8' SCALE: 1/4" = 1'-0" EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV Revision Schedule Number Description Date 5 3 3.1 2.1 CB 4 1.1 2 6 A-4546 1 3 4 A-454 2 5 2' - 8 1/2" W-C D-G01 D-G01 D-X15B D-X06 D-G01 D-G01 D-207B D-G019' - 11"2' - 11"14' - 1"9' - 4 3/4"19' - 1 3/4"1' - 9 1/2" 3' - 8 3/4"11' - 4"1' - 10 1/2"5' - 6"10' - 7"17' - 1 3/4"2' - 2"10' - 7"2' - 10" 1' - 10 1/4" 4' - 8 3/4"9' - 11"5' - 2 1/2"7' - 1 1/2"5' - 7 1/4"7' - 1"1' - 3 1/4"5' - 5" 5' - 5 1/2" 5' - 6"1' - 10"2' - 0"1' - 1 1/2"1' - 8 1/2"8' - 0 1/2"2' - 10"0' - 7 1/4"5' - 6 1/4"0' - 3" 5' - 8 1/4" 6.1 C.1 E CB 8.1 9 7 8 6 A-45410 7 8 9 5' - 1 3/4"1' - 6 1/2" 0' - 0 3/4"5' - 5" 0' - 4 1/2"1' - 9 1/4"5' - 8 1/4"11' - 9 3/4"0' - 4"10' - 8 3/4"1' - 3 3/4"0' - 4" 7' - 1 1/4" 0' - 4" 6' - 9"7' - 2 1/4" 0' - 11 3/4" 1' - 0"3' - 2 1/4"8' - 3 3/4"12' - 9 1/2"D-G01 D-X09 D-G01 18' - 4 1/2"11' - 6"5' - 8 1/2" 1' - 10 1/4" 7' - 4 1/4"12' - 0 1/4"12' - 0 3/4"7' - 0 1/4" 4' - 11 1/2" 5' - 2 3/4" 4' - 11 3/4" 5' - 7 1/2"5' - 1"D-X17 5' - 5 1/4"D-G01 5' - 11 1/2"5' - 8 1/2"D-G01 D-G01 A-504 4 53 5 8 7 6 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216ENLARGED PLAN &INTERIOR ELEVATIONS -TYP. LVL. GUESTCORRIDOR WEST WING A-453 FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 1/4" = 1'-0" Reference: 1 / A-123 1L02-05 ENLARGED GUEST CORR.- WEST WING - GRID 1.1 - 6.1 1/4" = 1'-0" Reference: 1 / A-123 2L02-05 ENLARGED GUEST CORR.- WEST WING - GRID 6 - 8 0'2' 4'8' SCALE: 1/4" = 1'-0" EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV Revision Schedule Number Description Date WC-10 D-X15BPL-15 RB-10 PT-15 533.12.1 3 A-302 42 6 D-G01 D-G01 D-207B WC-11 WC-10 WC-11 WC-10 WC-11 WC-02 RB-10RB-10RB-10PT-11PL-01 D-G106 PT-11PL-01 PT-11PL-01 PT-11 OPEN TO CORRIDOR WC-10 RB-10 5 33.1 2.1 3 A-302 4 26 D-G01D-G01 D-X06 D-G01 WC-11 WC-10 WC-10 WC-11 WC-11 WC-10 RB-10RB-10RB-10 D-G01 PL-01PT-11PL-01PT-11 PL-11 PT-03 PL-01 PT-11 PL-01 PT-11 OP-706 PT-10 RB-10 W-C WC-10 D-X15B PL-15 PT-15 DC.1EC 1 A-302 OPEN TO CORRIDORD-X17 WC-10WC-10 RB-10RB-10 OP-706 PL-15 PT-15WC-10 6.1 1 A-301 8.1786 OPEN TO CORRIDOR WC-10 WC-10 WC-10 RB-10RB-10 D-X09 PL-11PT-11 OP-706 C.1EC 1 A-302 OPEN TO CORRIDOR WC-10WC-11WC-10 RB-10RB-10RB-10 PT-10 PT-10 PL-01PT-11PL-01PT-11 W-C D-G01D-G01 6.1 1 A-301 8.1 78 6 D-G01 D-G01 WC-10 WC-11 WC-11 WC-10 WC-10 WC-11 RB-10 RB-10 RB-10 OP-706 PT-11PL-01PT-11PL-01 D-G01 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216INTERIOR ELEVATIONS -TYP. LVL. GUESTCORRIDOR WEST WING A-454 FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 FFL FFL 1/4" = 1'-0" Reference: 1 / A-453 1TYP. LVL. GUEST CORR.- WEST WING ELEV. A 1/4" = 1'-0" Reference: 1 / A-453 3TYP. LEVEL GUEST CORRIDOR- WEST WING ELEV. B 1/4" = 1'-0" Reference: 1 / A-453 4TYP. LVL. GUEST CORR.- WEST WING ELEV. C 1/4" = 1'-0" Reference: 1 / A-453 6TYP. LEVEL GUEST CORRIDOR- WEST WING ELEV. D 1/4" = 1'-0" Reference: 1 / A-453 2TYP. LVL. GUEST CORR.- WEST WING ELEV. A1 1/4" = 1'-0" Reference: 1 / A-453 5TYP. LVL. GUEST CORR.- WEST WING ELEV. C1 FFL 1/4" = 1'-0" Reference: 1 / A-422 7TYP. LEVEL GUEST CORRIDOR- WEST WING ELEV. E 1/4" = 1'-0" Reference: 1 / A-453 8TYP. LEVEL GUEST CORRIDOR- WEST WING ELEV. F FFL 1/4" = 1'-0" Reference: 1 / A-422 9TYP. LEVEL GUEST CORRIDOR- WEST WING ELEV. G 1/4" = 1'-0" Reference: 1 / A-453 10TYP. LEVEL GUEST CORRIDOR- WEST WING ELEV. H 0'2' 4'8' SCALE: 1/4" = 1'-0" EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV Revision Schedule Number Description Date UP UP DN DN 3.1 B 4 4 A-501 -0' - 0 1/2" 7' - 1 1/4"4' - 0 1/2"0' - 4 3/4"4' - 0 3/4"4' - 0 1/2" 13 EQ TREADS 11' - 11" CPT-14CPT-14 P4.2 P4.1 P4.2 P1.2XE1/2 D-106A D-106 3.1 B 4 4 A-501 4' - 0 1/2" 9 EQ TREADS 8' - 3"10' - 9 1/4" 7' - 1 1/4"4' - 0 1/2" 13 EQ TREADS 11' - 11" CPT-14CPT-14 D-X06 P4.2 P4.1 P4.2 XE1/2 P1.2 3.1 B 4 4 A-501 4' - 0 1/2"19' - 0 1/4" CPT-14CPT-14 P4.2 P4.1 P4.2 XE1/2 P1.2 D-X06 4' - 0 1/2" 9 EQ. TREADS 8' - 3"10' - 9 1/4" FLOOR 10' - 0" FLOOR 216' - 0" FLOOR 327' - 0" FLOOR 549' - 0" MAIN ROOF61' - 2" BO ROOF STRUC.60' - 0" LOW PARAPET63' - 10" B SITE-0' - 6"3' - 10 1/2"TYP.3' - 0"TYP.3' - 0"28 EQ RISERS16' - 0"8' - 0"20 EQ RISERS11' - 0" (TYP. 2ND-5TH FLOOR)5' - 6"5' - 6"3' - 6"3' - 0"ACT ACOUSTIC CEILING TILEASALUMINUM STOREFRONTCGCORNER GUARDCONC CONCRETE, UNFINISHEDCPCARPETCPTCARPET TILECSCONCRETE, FINISHEDGWBGYPSUM WALL BOARDFCFIBER CEMENTFRPFIBERGLASS-REINFORCEDPLASTICMR GWB MOISTURE-RESISTANT GYPSUM WALL BOARDPLPLASTIC LAMINATEPTPAINT/POWDER COATQTQUARRY TILERBRUBBER BASERESRESILIENT TILE FLOORSCSTAMPED CONCRETESFSPECIALTY FINISH (KNOCK DOWN)SS ENGINEERED SOLID SURFACESTSTONESTLSTAINLESS STEELSTRUC STRUCTURE ABOVEVCTVINYL COMPOSITE TILEWCVINYL WALL COVERINGWDWOOD-LOOK ALUMINUM SLATS AND BATTENSWPSCREEN WALL NOTE: REFER TO FF&E PACKAGE AND SPECIFICATION BOOK FOR FURNITURE AND FINISH SPECIFICATIONS FINISH LEGEND 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216STAIR 1 DETAILS A-501 FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 3/8" = 1'-0" Reference: 1 / A-121 1STAIR 1 PLAN - 1ST FLOOR Room 106 3/8" = 1'-0" Reference: 1 / A-123 2STAIR 1 PLAN - 2ND - 4TH FLOOR, TYP. Room 106 3/8" = 1'-0" Reference: 1 / A-105 3STAIR 1 PLAN - 5TH FLOOR Room 106 3/8" = 1'-0" Reference: 1 / A-501 4STAIR 1 SECTION Room 106 0'1'-4" 2'-8"5''-4" SCALE: 3/8" = 1'-0" EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV Revision Schedule Number Description Date UP UP DN DN M L.1 9 4 A-502 8 4' - 10"0' - 4 1/2"4' - 9 1/2"4' - 11" 13 EQ TREADS 12' - 0"6' - 2" D-X32D-G107 P4.3 P4.1 P4.1 XE1/2P1.2 CPT-14CPT-14 M L.1 9 4 A-502 5' - 0" 13 EQ. TREADS 11' - 11"6' - 2"4' - 10"0' - 4 3/4"4' - 9 1/2"8 5' - 0" 9 EQ TREADS 8' - 3"9' - 10" P4.3 P4.1 P4.1 XE1/2 D-X32 P1.2 CPT-14CPT-14 M L.1 9 4 A-502 8' - 7" 5' - 0" 9 EQ TREADS 8' - 3"9' - 10"4' - 10"8 ROOF ACCESS 539D-532 D-X32 XE1/2 P4.3 P4.1 P4.1 P1.2 P10 P1.2 CPT-14CPT-14 CPT-14 FLOOR 10' - 0" FLOOR 216' - 0" FLOOR 327' - 0" FLOOR 549' - 0" MAIN ROOF61' - 2" BO ROOF STRUC.60' - 0" LOW PARAPET63' - 10" SITE-0' - 6" 9 TYP.3' - 0"28 EQ. RISERS16' - 0"20 EQ RISERS11' - 0" (TYP. LEVEL 02-05)3' - 10 1/2"8 ROOF ACCESS 539 P10 ACT ACOUSTIC CEILING TILEASALUMINUM STOREFRONTCGCORNER GUARDCONC CONCRETE, UNFINISHEDCPCARPETCPTCARPET TILECSCONCRETE, FINISHEDGWBGYPSUM WALL BOARDFCFIBER CEMENTFRPFIBERGLASS-REINFORCEDPLASTICMR GWB MOISTURE-RESISTANT GYPSUM WALL BOARDPLPLASTIC LAMINATEPTPAINT/POWDER COATQTQUARRY TILERBRUBBER BASERESRESILIENT TILE FLOORSCSTAMPED CONCRETESFSPECIALTY FINISH (KNOCK DOWN)SS ENGINEERED SOLID SURFACESTSTONESTLSTAINLESS STEELSTRUC STRUCTURE ABOVEVCTVINYL COMPOSITE TILEWCVINYL WALL COVERINGWDWOOD-LOOK ALUMINUM SLATS AND BATTENSWPSCREEN WALL NOTE: REFER TO FF&E PACKAGE AND SPECIFICATION BOOK FOR FURNITURE AND FINISH SPECIFICATIONS FINISH LEGEND 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216STAIR 2 DETAILS A-502 FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 3/8" = 1'-0" Reference: 1 / A-122 1STAIR 2 PLAN - 1ST FLOOR Room 132 3/8" = 1'-0"2STAIR 2 PLAN - 2ND - 4TH FLOOR TYP. 3/8" = 1'-0" Reference: 1 / A-105 3STAIR 2 PLAN - 5TH FLOOR Room 132 3/8" = 1'-0" Reference: 1 / A-502 4STAIR 2 SECTION Room 132 0'1'-4" 2'-8"5''-4" SCALE: 3/8" = 1'-0" EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV Revision Schedule Number Description Date FLOOR 10' - 0" FLOOR 216' - 0" FLOOR 327' - 0" FLOOR 549' - 0" MAIN ROOF61' - 2" BO ROOF STRUC.60' - 0" MIDDLE PARAPET65' - 10" SITE-0' - 6"11' - 0"16' - 0"DOOR OPENING7' - 0" TYP.22' - 0"TYP. LEVEL 03 TO 05 @ 11' FLR TO FLR HEIGHTSHAFTELEVATOR PIT5' - 0"XD4 XD4 P5.1P5.2 P5.1P5.2 XD6 XD6 P5.2P5.1 5 4 A-503 6 3 A-5038' - 8"0' - 7 1/2"4' - 4 3/4"VER.3' - 6"2' - 7"VER.3' - 6"9' - 1"0' - 7 1/2"ELEV 1 111 ELEV 2 1132' - 9 1/4"2' - 6 1/4"2' - 5 1/4"3' - 6"4' - 0 1/2"P5.1 P5.4 P5.2 P5.4 P5.3 XE4 XE4 XE4 P5.5 P5.5 XE1/2 8' - 8"D-X13 D-X11 D-X11A LINEN CHUTE 140 4 A-503 6 3 A-503 ELEV 2 113 ELEV 1 111 P5.4 XD6 XD6 XD6 XD6 FLOOR 10' - 0" FLOOR 216' - 0" FLOOR 327' - 0" FLOOR 549' - 0" MAIN ROOF61' - 2" 6.1 BO ROOF STRUC.60' - 0" SITE-0' - 6" 6 SHAFTSHAFTDOOR OPENING7' - 0" TYP.XD6 XD6 P5.4 P5.3 P5.4 P5.3 P5.4 P5.4 P5.4 XE4 P5.3 4' - 9"SAFETY BEAM(NOT BY OTIS) TOP RAIL SUPPORT(NOT BY OTIS) CRITICAL LOCATION CRITICAL LOCATION SECOND RAIL SUPPORT(NOT BY OTIS) (ONLY REQUIRED ON THE OPPOSITE SIDE OF CWT.)4" MINCRITICAL LOCATION CENTER OF RAIL BRACKETSEE SECTIONAL ELEVATIONTOP LANDING ** ALL LOCATION DIMENSIONS TO FOLLOW A TOLERANCE OF ±1"JAMB DEPTHMINIMUM2 LAYERS OF 1/2" DRYWALL (MINIMUM) REQUIRED AT BACK OF CONTROLLER.WALL DEPTHMINIMUMCONDITIONPER BUILDINGALTERNATE CONSTRUCTION ELEVATOR LOBBY CONTROLLER 2' - 2" MINIMUM TUBE STEEL FLUSH WITH HOISTWAY (NOT BY OTIS)1' - 1"4' - 3 13/16"INSIDE HOISTWAY TUBE STEEL FLUSH WITH HOISTWAY (NOT BY OTIS)1' - 1"4' - 3 13/16"TUBE STEEL FLUSH WITH HOISTWAY (NOT BY OTIS) TUBE STEEL FLUSH WITH HOISTWAY (NOT BY OTIS) INSIDE HOISTWAY 2' - 5 5/8"2' - 5 5/8"LADDER 0' - 4 1/2" 1" MAX LADDER16"SILL ASSEMBLY(BY OTIS) FINISHED FLOOR GROUT STOPDOOR SPACE FRONT WALL LINE SILL LINE ADEQUATE SUPPORT AT ALL FASTENING POINTS OF ENTRANCE ASSEMBLY REQUIRED. MUST WITHSTAND HORIZONTAL PULL-OUT FORCE OF 140 LBS. @ EA. FASTENING POINT (8 @ EA. ENTRANCE) INCLUDING SUPPORT FOR CENTER SILL SUPPORT BRACKET (NOT BY OTIS) 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216ELEVATOR DETAILS A-503 FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 3/8" = 1'-0" Reference: 1 / A-503 4ELEVATOR CROSS SECTION 3/8" = 1'-0" Reference: 1 / A-431 1ELEVATOR SHAFT PLAN 0'6" 1'2' SCALE: 1" = 1'-0" 3/8" = 1'-0"2ELEVATOR PIT PLAN 3/8" = 1'-0"3ELEVATOR LONGITUDINAL SECTION 3/16" = 1'-0"5 MACHINE DETAIL 1" = 1'-0"6 FRONT TOP LANDING ENTRANCE REQUIREMENTS NO. 2 3/4" = 1'-0"7 TUBE STEEL RAIL BRACKET SUPPORT 1/2" = 1'-0"9 LADDER DETAIL 1" = 1'-0"8 DETAIL "A" SILL SUPPORT 0'8" 1' 4"2' 8" SCALE: 3/4" = 1'-0" 0'1' 2'4' SCALE: 1/2" = 1'-0" 0'1'-4" 2'-8"5''-4" SCALE: 3/8" = 1'-0" EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV Revision Schedule Number Description Date E 176 SF ELEVATORLOBBY 117 64 SF ELEV 2 113 68 SF ELEV 1 1114 A-503 8' - 2 1/4"0' - 4 3/4" A-43315 13 14 7 6 3 A-503 D-117 D-X11 D-X13 D-X11A LINEN CHUTE 140 E 4 A-503 157 SF ELEVATOR LOBBY 217 D-X17 W-C 4' - 0"2' - 3 1/4"0' - 5 1/4"19' - 3"68 SF ELEV 1 111 64 SF ELEV 2 113 7 6 3 A-503 D-X13 D-X11 D-X11A A-504 4 53 1 A-301 3' - 0"4' - 0"PA-504 CENTER ON ELEVATOR DOORS 1 WC-11 RB-10 1 A-301 4 A-503 ELEVATOR DOORELEVATOR DOOR 2 4 3 PA-204PA-204 EQEQ 3' - 10"3' - 10"6' - 0"7' - 0"WC-11 RB-10 W-C WC-11 RB-10 ACT ACOUSTIC CEILING TILEASALUMINUM STOREFRONTCGCORNER GUARDCONC CONCRETE, UNFINISHEDCPCARPETCPTCARPET TILECSCONCRETE, FINISHEDGWBGYPSUM WALL BOARDFCFIBER CEMENTFRPFIBERGLASS-REINFORCEDPLASTICMR GWB MOISTURE-RESISTANT GYPSUM WALL BOARDPLPLASTIC LAMINATEPTPAINT/POWDER COATQTQUARRY TILERBRUBBER BASERESRESILIENT TILE FLOORSCSTAMPED CONCRETESFSPECIALTY FINISH (KNOCK DOWN)SS ENGINEERED SOLID SURFACESTSTONESTLSTAINLESS STEELSTRUC STRUCTURE ABOVEVCTVINYL COMPOSITE TILEWCVINYL WALL COVERINGWDWOOD-LOOK ALUMINUM SLATS AND BATTENSWPSCREEN WALL NOTE: REFER TO FF&E PACKAGE AND SPECIFICATION BOOK FOR FURNITURE AND FINISH SPECIFICATIONS FINISH LEGEND 3/8" = 1'-0" Reference: 1 / A-122 11ST FLOOR ELEVATOR LOBBY Room 117 3/8" = 1'-0" Reference: 1 / A-124 22ND-5TH FLOORS (TYPICAL) ELEVATOR LOBBY Rooms 217, 317, 417 & 517 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216ELEVATOR LOBBYDETAILS A-504 FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 0'1'-4" 2'-8"5''-4" SCALE: 3/8" = 1'-0" 3/8" = 1'-0" Reference: 1 / A-102 5TYP. ELEVATOR LOBBY - EAST ELEVATION Rooms 217, 317, 417 & 517 3/8" = 1'-0" Reference: 1 / A-102 3TYP. ELEVATOR LOBBY - WEST ELEVATION Rooms 217, 317, 417 & 517 FURNISHING SCHEDULE GUESTROOM FURNISHINGS GR-103 CHAIR - KITCHEN STOOL GR-201 SCONCE - NIGHTSTAND GR-308 NIGHTSTAND - REGULAR GR-318 DRESSER - HIGHBOY GR-326 VANITY - STUDIO AND 1-BEDROOMSUITES GR-503 ART- ENTRY GR-506 MIRROR - GUESTROOM FULL LENGTH GR-508 MIRROR - GUESTROOM VANITY GR-907 CLOCK/RADIO GR-908 TELEPHONE - GUESTROOM GR-KS BED - KING (GR-301, 303, 600) PUBLIC AREA FURNISHINGS PA-100 BENCH - DINING ROOM BANQUETTE PA-204 SCONCE - PUBLIC AREAS PA-504 ART - TYPICAL ELEVATOR LOBBY PA-505 ART - 1ST FLOOR ELEVATOR LOBBY PLUMBING/MECHANICAL FIXTURES PF-01 TOILET - GUESTROOM PF-07 LAVATORY - UNDERMOUNT, 20" X 14" PF-15 FAUCET - LAVATORY TOILET ACCESSORIES HD-01 DUAL TOILET PAPER HOLDER HD-04.1 TOWEL BAR HD-21 BULK AMENITY DISPENSER ATLAVATORIES KEYNOTES - ENLARGED 1 2-WAY AREA OF REFUGE COMMUNICATION WITHFRONT DESK. 2 CARD READER TO CALL SERVICE ELEVATOR 3 CALL BUTTONS WITH LOCK PER AHJREQUIREMENTS. 4 ELEVATOR INDICATORS 5 AFTER-HOURS ACCESS INTERCOM-CONNECTED TO FRONT DESK. 6 KITCHEN HOOD VENT 7 FRP PANELS ON WALLS TO BE WELDED AT ALLSEAMS. ENSURE ALL SEAMS BETWEENDIFFERING MATERIALS ARE BACKED ANDSEALED IN ORDER TO MAINTAIN A SANITARY,WASHABLE ENVIRONMENT. 8 CLEAR TEMPERED, PLATED MIRROR 9 FLAT SCREEN TV. 10 PROVIDE ARTICULATING ARM FORWALL-MOUNTED TV. 11 PROVIDE FULL SUITES OF DATA/VIDEO/POWERUNDER AND BEWTEEN THE WINDOWS ALONGALL WALLS. 12 MACHINES TO BE SET UP FOR CARD ACCESSONLY. COORDINATE POWER AND DATA WITHSUPPLIER. 13 USE CORNER GUARDS ON ALL SURFACESFINISHED WITH WALL COVERING IN PUBLICAREAS. 3/8" = 1'-0" Reference: 2 / A-453 4TYP. ELEVATOR LOBBY - S. ELEV. Rooms 217, 317, 417 & 517 EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV Revision Schedule Number Description Date 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216CANOPY DETAILS A-505 FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 3/8" = 1'-0" Reference: 1 / A-102 1PORTE COCHERE EAST-WEST SECTION 3/8" = 1'-0" Reference: 1 / A-102 3PORTE COCHERE NORTH-SOUTH SECTION 3/4" = 1'-0" Reference: 3 / A-505 2 CANOPY DETAIL AT LOBBY ENTRANCE 0'8" 1' 4"2' 8" SCALE: 3/4" = 1'-0" 0'1'-4" 2'-8"5''-4" SCALE: 3/8" = 1'-0" EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV Revision Schedule Number Description Date 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216CANOPY DETAILS A-506 FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 1 1/2" = 1'-0" Reference: 1 / A-505 1PORTE COCHERE SLOPED EDGE 3/4" = 1'-0" Reference: 3 / A-505 2PORTE COCHERE AT ROOF DRAIN 0'4" 8"1' 4" SCALE: 1 1/2" = 1'-0" 0'6" 1'2' SCALE: 1" = 1'-0" EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV Revision Schedule Number Description Date MAIN ROOF61' - 2" BO ROOF STRUC.60' - 0" LOW PARAPET63' - 10" MIDDLE PARAPET65' - 10" HIGH PARAPET69' - 10" MAX BLDG HEIGHT71' - 2" 910 1' - 4"4' - 0"2' - 0"2' - 8"737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216ROOF DETAILS A-507 FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 3/4" = 1'-0" Reference: 1 / A-106 1ROOF PARAPET HEIGHTS 0'8" 1' 4"2' 8" SCALE: 3/4" = 1'-0" EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV Revision Schedule Number Description Date REINFORCING MESH AND BASE COAT EMBEDDED. NOTE. 2 1/2" (63MM) MIN. OVERLAP AT REINFORCING MESH REINFORCING MESH EMBEDDED IN BASE COAT FINISH EXPANDED POLYSTYRENE MIN. 3/4" (19 MM) MIN. 3/4" (19 MM) PITCH FOR POSITIVE DRAINEDGE ADHESIVE EXPANDED POLYSTYRENE REINFORCING MESH EMBEDDED IN BASE COAT FINISH SEE DETAILS FOR EXPANSION JOINT SEE DETAILS FOR EXPANSION JOINT ADHESIVE EXPANDED POLYSTYRENE REINFORCING MESH EMBEDDED IN BASE COAT FINISH INSULATION SUBSTRATE ADHESIVE EXPANDED POLYSTYRENEBLOCKING ELASTOMERIC SEALANT CORROSION RESISTANT FASTENER P.V.C. PIPE SLEEVE FILLED WITH ELASTOMERIC SEALANT FINISH REINFORCING MESH EMBEDDED IN BASE COAT PVC PIPE SLEEVE INSERTED INTO PRE-DRILLED HOLES FRAMING SHEATHING EXPANDED POLYSTYRENE HANDRAIL POST PRE-DRILLED HOLES ILLUSTRATION "A"ILLUSTRATION "B" ELASTOMERIC SEALANT FASTENER EXPANDED POLYSTYRENE ADHESIVE DOUBLE WRAP WITH REINFORCING MESH EMBEDDED BASE COAT FINISH FINISH REINFORCING MESH EMBEDDED IN BASE COAT EXPANDED POLYSTYRENE ADHESIVE MESH BACKWRAP CLOSED CELL POLYETHYLENE BACKER ROD AND ELASTOMERIC SEALANT, JOINT WIDTH MINIMUM 3/4" (19MM). JAMB CLOSED CELL POLYETHYLENE BACKER ROD AND ELASTOMERIC SEALANT DOUBLE WRAPPED REINFORCING MESH EMBEDDED IN BASE COAT FINISH REINFORCING MESH EMBEDDED IN BASE COAT EXPANDED POLYSTYRENE ADHESIVE SUBSTRATE SUBSTRATE ADHESIVE EXPANDED POLYSTYRENE REINFORCING MESH EMBEDDED IN BASE COAT FINISH 3/4" (19 MM) MIN. EXPANDED POLYSTYRENE SEE THICKNESS FOR GROOVE OUTSIDE CORNER SEE DETAIL3" (75 MM) MAX. INSIDE CORNER SEE DETAIL ADHESIVE EXPANDED POLYSTYRENE DOUBLE WRAP WITH REINFORCING MESH EMBEDDED BASE COAT FINISH SUBSTRATEADHESIVE EXPANDED POLYSTYRENE RECOMMENDED HIGH IMPACT REINFORCING MESH EMBEDDED IN BASE COAT REINFORCING MESH EMBEDDED IN BASE COAT FINISH MESH BACKWRAP FOUNDATION 6" (150 MM) MIN TO GRADE INSULATION SUBSTRATE ADHESIVE EXPANDED POLYSTYRENE RECOMMENDED HIGH IMPACT REINFORCING MESH EMBEDDED IN BASE COAT REINFORCING MESH EMBEDDED IN BASE COAT FINISH MESH BACKWRAP FOUNDATION PAVEMENT 2" (50 MM) MIN. INSULATION SUBSTRATEADHESIVE EXPANDED POLYSTYRENE REINFORCING MESH EMBEDDED IN BASE COAT FINISH MESH BACKWRAP INSULATION CLOSED CELL BACKER ROD AND ELASTOMERIC SEALANT BALCONY DECK ELASTOMERIC SEALANT WATERTIGHT ELECTRICAL BOX/HOSE BIBB SHEATHING ADHESIVE EXPANDED POYSTYRENE ELASTOMERIC SEALANT FIXTURE BOX COVER REINFORCING MESH EMBEDDED IN BASE COAT FINISH 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216EIFS DETAILS A-509 FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 3" = 1'-0"1AESTHETIC GROOVE REVEAL 3" = 1'-0"2BUILDING ISOLATION JOINT 0'1" 2"4" SCALE: 6" = 1'-0" 3" = 1'-0"3DISSIMILAR SUBSTRATES 3" = 1'-0"4 FIXTURE ATTACHMENT (BY OTHERS) 3" = 1'-0"5HANDRAIL ATTACHMENT (BY OTHERS) 6" = 1'-0"6INSIDE CORNER 0'2" 4"8" SCALE: 3" = 1'-0" 3" = 1'-0"7INSIDE CORNER AT DISSIMILAR SUBSTRATE 3" = 1'-0"8 INSULATED JAMB RETURN 3" = 1'-0"14INSULATED SOFFIT 6" = 1'-0"9OUTSIDE CORNER 3" = 1'-0"10TERMINATION ABOVE GRADE 3" = 1'-0"11TERMINATION ABOVE PAVEMENT 3" = 1'-0"12 TERMINATION AT BALCONY EDGE 6" = 1'-0"13TERMINATION AT HOSE BIBB/ELECTRICAL FIXTURE EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV Revision Schedule Number Description Date 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216ROOF DETAILS A-508 FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 0'2" 4"8" SCALE: 3" = 1'-0" EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV REVISION SCHEDULE # DESCRIPTION DATE 2 ADDENDUM 2 6/21/2024 RESILIENT FLOORING RE:FINISH SCHEDULE TRANSITION STRIP; REFER TO CARPET SPEC FOR TRANSITION FINISH CARPET PAD AS SCHEDULED CARPET AS SCHEDULED TILE OVER DRY-SET / LATEX-PORTLAND CEMENT THINSET MORTAR FLUSH BRUSHED STAINLESS STEEL TRANSITION STRIP RESILIENT FLOORING -FINISHED SURFACE TO BE LEVEL W/ TRANSITION STRIP WALL COVERING AS SPECIFIED RUBBER BASE HEIGHT OF RUBBER BASE AND TILE TO ALIGN TILE BASE WALL COVERING AS SPECIFIED RUBBER BASE HEIGHT OF RUBBER BASE AND TILE TO ALIGN TILE BASE MOISTURE RESISTANT GYPSUM SHOWER/TUB SURROUND EDGE OF SHOWER PAN OR TUB CONTINUOUS SEALANT TILE BASE WALL COVERING AS SPECIFIED 0' - 8"0' - 8"0' - 6" INSTALLATION CLIP BRACKET M FACE MOUNT 3" ROLLER SHADE FASCIA COVER LIGHTING AS SPECIFIED; TOP OF LIGHT SOURCE TO ALIGN WITH EDGE OF COVE STAINLESS STEEL CHAIN SHEER ROLLER SHADE 0' - 10"0' - 6"0' - 6" CEILING FINISHED TO EXTEND INTO COVE LIGHTING AS SPECIFIED; TOP OF LIGHT SOURCE TO ALIGN WITH EDGE OF COVE 8" WIDE LAMINATE PLANKS ON Z-CLIPS 0' - 3"1' - 2"0' - 6"0' - 6" LIGHTING AS SPECIFIEDTOP OF LIGHT SOURCE TO ALIGN WITH EDGE OF COVE PLASTIC LAMINATE FRAME 0' - 6"0' - 6"0' - 6"LIGHTING AS SPECIFIEDTOP OF LIGHT SOURCE TO ALIGN WITH EDGE OF COVE ACOUSTIC CEILING 10'-10"AFF0' - 4"8" WIDE LAMINATE PLANKS ON Z-CLIPS EXTERIOR FINISH EXTERIOR INTERIOR0' - 8"0' - 0 3/4"0' - 10" 1/4" REVEAL FACE OF WALL WINDOW SYSTEM AS SCHEDULED PLYWOOD BLOCKING (PAINT TO MATCH CEILING) OWNER FURNISHED DRAPERY & TRACK 3/4" PAINTED MDF GUESTROOMGUESTROOM DOOR AND FRAME BEYOND FULL SWEEP, TYP. EACH DOOR (AS SPECIFIED) ADJUSTABLE VINYL THRESHOLD (AS SPECIFIED) RESILIENT FLOORING GUESTROOMCORRIDOR DOOR AND FRAME BEYOND SWEEP (AS SPECIFIED) VINYL THRESHOLD(AS SPECIFIED) CORRIDOR CARPET RESILIENT FLOORING RE: FINISH SCHEDULE TRANSITION STRIP; TARKETT, CD-48-C RESILIENT FLOORING RE: FINISH SCHEDULE DOOR AND FRAME BEYOND CARPET AS SCHEDULED DOOR AND FRAME BEYOND TILE OVER DRY-SET / LATEX-PORTLAND CEMENT THINSET MORTAR FLUSH STAINLESS STEEL TRANSITION STRIP RESILIENT FLOOR COVERING VINYL TO BE LEVEL W/ TRANSITION STRIP EXTERIOR FINISH EXTERIOR INTERIOR0' - 8"0' - 0 3/4"0' - 10" 1/4" REVEAL FACE OF WALL WINDOW SYSTEM AS SCHEDULED PLYWOOD BLOCKING (PAINT TO MATCH CEILING) OWNER FURNISHED DRAPERY & TRACK 3/4" PAINTED MDF 3" = 1'-0" Reference: 2 / A-411A 1RES TO CARPET TRANSITION 3" = 1'-0" Reference: 2 / A-411A 2RES TO TILE TRANSITION 3" = 1'-0" Reference: 1 / A-423 3TILE TO RUBBER BASE AT WALL END Efficiency Suite Guest Baths 3" = 1'-0" Reference: 3 / A-423 4 TILE TO RUBBER BASE TRANS AT CORNER Efficiency Suite Guest Baths 3" = 1'-0" Reference: 1 / A-423 5 TILE TRANSITION AT TUB Guest Baths 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216TRANSITION,THRESHOLD, & CEILINGDETAILS A-510 FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 1 1/2" = 1'-0" Reference: 1 / A-112 11LIGHT SHADE AT RM PERIMETER 1 1/2" = 1'-0" Reference: 1 / A-112 12LIGHT COVE AT PLASTIC LAMINATE/ACT 1 1/2" = 1'-0" Reference: 1 / A-112 13LIGHT COVE AT NICHE SOFFIT 1 1/2" = 1'-0" Reference: 1 / A-112 14 LIGHT COVE AT GWB/ACT 1 1/2" = 1'-0" Reference: 1 / A-112 15 DETAIL AT PLASTIC LAMINATE/GWB 1 1/2" = 1'-0"16GUESTROOM DRAPERY VALENCE 1" = 1'-0" Reference: 2 / A-411A 7CONNECTOR THRESHOLD 1" = 1'-0" Reference: 1 / A-412A 6ENTRY THRESHOLD 1" = 1'-0" Reference: 2 / A-417A 8CARPET TO RES AT DOOR 1" = 1'-0"9 TILE TO RES AT DOOR 1 1/2" = 1'-0"17WALL-ATTACHED VALENCE NOT USED 0'2" 4"8" SCALE: 3" = 1'-0" 0'4" 8"1' 4" SCALE: 1 1/2" = 1'-0" 0'6" 1'2' SCALE: 1" = 1'-0" EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV Revision Schedule Number Description Date X Y RUNNING SLOPE1:20 MAX RUNNING SLOPE1:12 MAXCOUNTERSLOPE1:20 MAX WALKCURB RAMPSTREET NOTE:(1)SLOPE = Y/X WHERE X IS A LEVEL PLANE(2)COUNTERSLOPE SHALL NOT EXCEED 1:20 MEASUREMENT OF CURB RAMP SLOPES GROUND SURFACESHALL BE SLIP RESISTANT FLARED SIDES101 X 36" MIN NOTE:IF X<48", THEN THE SLOPE OF THE FLARED SIDES SHALL NOT EXCEED 1:12 FLARED SIDE RETURNED CURB PLANTING OR OTHER NON WALKING SURFACE BUILT UP TO CURB RAMP 10 136" MI N 5' - 0"CLEAR3' - 6"PER SLOPE6'-0" MAXPROVIDE HEAVY BROOM FINISH (GRAY CONC.) OR STAMPED PATTERN (COLORED) PER PLAN, PERPENDICULAR TO SLOPE OF RAMP IN AREAS OUTSIDE OF DECTABLE WARNING SURFACE DETACTABLE WARNING SURFACE - 2'-O" D. x RAMP WIDTH - PROVIDE ONLY WHERE REQUIRED BY LOCAL CODESLANDING SLOPE CURB DN 1:10 MAX SLOPE CURB DN 1:10 MAXSLOPE DOWN1:12 MAXCONC CURB CAST-IN-PLACE DETACTABLE WARNING SYSTEM BY ADA TACTILE SYSTEMS (978-262-9900) OR ARMOR TILE TACTILE SYSTEMS (800-682-2535) COLOR OF DETECTABLE WARNING SHALL BE CONTRASTING COLOR (DARK ON LIGHT CONCRETE OR LIGHT ON DARK CONCRETE/ASPHALT) SLOPE OF RAMP SURFACE SHALL NOT EXCEED 1:12 - PROVIDE HEAVY BROOM FINISH PERPENDICULAR TO SLOPE OF RAMP 121 MAXWARNING FULL 2'-0" DETACTABLE WIDTH OF RAMP 0' - 4"12"1'-0" x 2'-0" x .080 REFLECTIVE ALUMINUM SIGN - SEE DETAIL RESERVE PARKING 1 1/2" X 5/16" LETTERS 6" HIGH x 6 3/4" WIDE ADA SYMBOL 1" x 3/16" LETTERS GRADE AT LANDSCAPE 1 3/4" x 1 3/4" x 0.105 PERFORATEDGALV STEEL TUBING 2" x 2"x0.105 PERFORATED GALVSTEEL TUBING SET IN CONC. BASE 8" x 5/8" ∅ ANCHOR BARS EACH WAY THROUGH TUBING 1'-0" ∅ CONCRETE FOOTING (TYP) 1' - 0"2' - 0"5' - 0"2"2' - 0"2"8"5' - 0"5' - 0"PAINT BLUE (TRAFFIC) PAINT WHITE (FIGURE) 3" WIDE, PAINTWHITE (BORDER)48" MIN - 60" MAXINSTALL ON THE RIGHT SIDE OF DOUBLE DOORS DOOR - MOUNTED SIGNAGE CORRESPONDING GRADE 2 BRAILLE HEIGHT OF LETTERING, 5/8" TO 2" MAX, WITH UPPER CASE CHARACTERS WALL MOUNTED SIGNAGE TO BE LOCATED ON LATCH SIDE OF DOOR & CLEAR OF DOOR SWING, MOUNT AT 48" MIN. 60" MAX TO CENTERLINE OF SIGN FROM FINISH FLOOR 12"12"12"MEN WOMEN UNISEX RESTROOMS HANDICAPPEDMEN ACCESSIBLERESTROOM TYPICAL WALL SIGNAGE TYPICAL WALL SIGNAGE PICTOGRAMS AND/OR LETTERING ARE NOT REQUIRED ON DOOR MOUNTED SIGNAGE MEN 46" MIN - 60" MAX12"12"APPROVED STAIRWAY IDENTIFICATION SIGNS SHALL BE LOCATED AT EACH FLOOR LEVEL IN ALL ENCLOSED STAIRWAYS IN BUILDING TWO OR MORE STORIES IN HEIGHT. THE SIGN SHALL IDENTIFY THE STAIRWAY, ROOF ACCESS, FLOOR LEVEL AND UPPER & LOWER TERMINUS OF THE STAIRWAY CORRESPONDING GRADE 2 BRAILLE TO BE LOCATED DIRECTLY UNDER OR ADJACENT TO SIGNAGE INFORMATION STRAIGHT IN APPROACH48" A.F.F.PARALLEL APPROACH54" TOP OF CABINET1 11/32" x 31/32" THREAD x 5/16" DIA. CORNER BOLT W/ 5/16" SELF LOCKING NUT ALUM SIGN GALV STEEL POST, PAINTED 1 9/16" x 1 3/16" THREAD EACHEND x 5/16" DIA. CORNER BOLTW/ (2) 5/16" SELF LOCKING NUT GALV STEEL POST, PAINTED DETAIL A DETAIL B 2"12" MAXNOTE: FOR REFERENCE ONLY MODIFY FOR SELECTED LIFT LOCATION OF ADA ACCESSIBLE POOL LIFT. PROVIDE ANCHORS OR SLEEVE AS REQUIRED MANUFACTURER. HYDRAULIC UNIT REQUIRES PLUMBING SPIGOT WITHIN WATER BOX. REVISE DETAIL FOR BATTERY POWERED UNIT. POOL OR SPA EDGE 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216ACCESSIBLE DETAILS A-511 FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 3/8" = 1'-0"1CURB RAMPS 1/4" = 1'-0"2 TYPICAL ADA RAMP 3/4" = 1'-0"3ADA CURB RAMP 3/4" = 1'-0"4ADA PARKING SIGN 3/4" = 1'-0"5ADA PARKING SYMBOL 3/8" = 1'-0"6 RESTROOM SIGNAGE 3/8" = 1'-0"7DOORWAY SIGNAGE 1/2" = 1'-0"8FIRE EXT. MOUNTING HEIGHT 3" = 1'-0"9ADA SIGN DETAILS 3/4" = 1'-0"10 LOW LEVEL EXIT SIGN 1/4" = 1'-0"11 ACCESSIBLE POOL LIFT 0'2" 4"8" SCALE: 3" = 1'-0" 0'8" 1' 4"2' 8" SCALE: 3/4" = 1'-0" 0'1' 2'4' SCALE: 1/2" = 1'-0" 0'1'-4" 2'-8"5''-4" SCALE: 3/8" = 1'-0" 0'2' 4'8' SCALE: 1/4" = 1'-0" EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV Revision Schedule Number Description Date DECEMBER 09, 2004F RATING-1HRT RATING-3/4HRDRAWING NOT TO SCALE SYSTEM NO. F-C-2135 NOVEMBER 30, 2004F RATINGS- 1AND 2 HR (SEE ITEM 1)T RATING-0HRL RATING AT AMBIENT - LESS THAN 1 CFM/SQ FTDRAWING NOT TO SCALE SYSTEM NO. W-L-1158 2 3B 2 3B 1B 1A 1D3B 3A 1C SECTION A-A A AA A SECTION A-A 3B 2 1A 3A 1BA A3B 2 3A 1B 1A SECTION A-A APRIL 14, 2004F RATINGS-1 & 2HR (SEE ITEMS 1 AND 2)T RATINGS-0, 1 & 2HR (SEE ITEMS 1 AND 2)DRAWING NOT TO SCALE SYSTEM NO. W-L-2129 A A 2 3B 1B 3A 1A 1D3B1C 2 3B SECTION A-A DECEMBER 09, 2004F RATING-1HRT RATING-3/4HRDRAWING NOT TO SCALE SYSTEM NO. F-C-2135 JANUARY 22, 2003HORIZONTAL (FLOOR)RATINGS: CAN/JLC-5115, 1 HOUR F, (FOR T RATINGS SEE ITEM 3)TEST PRESSURE DIFFERENTIAL - 50 PA (0.20" OF WATER) MINIMUMDRAWING NOT TO SCALE DESIGN NO. TL/PH 60-01 SECTION A-A 6 5 3 2 3 4 3 1 5 MARCH 21, 2005F RATING-2HRT RATINGS-0, J- 3/4 AND 2 HR (SEE ITEM 2)L RATING AT AMBIENT -16 CFM/SQ.FTDRAWING NOT TO SCALE SYSTEM NO. F-C-3085 A A2 3B 3B 1B 3A 3B 1D 1A 1C 2 1. FLOOR-CEILING ASSEMBLY - THE FIRE-RATED WOOD JOIST FLOOR-CEILING ASSEMBLY SHALL BE CONSTRUCTED OF THE MATERIAL AND IN THE MANNER SPECIFIED IN THE INDIVIDUAL L500 SERIES FLOOR CEILING DESIGNS IN THE UL FIRE RESISTANCE DIRECTORY, AS SUMMARIZED BELOW: A. FLOOR SYSTEM - LUMBER OR PLYWOOD SUB-FLOOR WITH FINISH FLOOR OF LUMBER, PLYWOOD OR FLOOR TOPPING MIXTURE AS SPECIFIED IN THE INDIVIDUAL FLOOR-CEILING DESIGN. MAX DIA. OF FLOOR OPENING IS 4 IN. (102MM). 2. THROUGH PENETRANTS - ONE NON METALLIC PIPE TO BE INSTALLED EITHER CONCENTRICALLY OR ECCENTRICALLY WITHIN THE FIRESTOP SYSTEM. PIPE TO BE RIGIDLY SUPPORTED ON BOTH SIDES OF THE FLOOR-CEILING ASSEMBLY. THE SPACE BETWEEN PIPE AND PERIPHERY OF OPENING SHALL BE MIN. 0 IN. (POINT CONTACT) TO MAX 1/2 IN. (13 MM). THE FOLLOWING TYPES AND SIZES OF NONMETALLIC PIPES MAY BE USED. B. WOOD JOISTS - NOM 2 BY 10 IN. (51 BY 254 MM) LUMBER JOISTS SPACED 16 IN. (406 MM) OC WITH NOM 1 BY 3 IN (25 BY 76 MM) LUMBER BRIDGING AND WITH ENDS FIRESTOPPED. AS AN ALTERNATE TO LUMBER JOISTS, NOM 10 IN. (254 MM) DEEP (OR DEEPER) LUMBER, STEEL OR COMBINATION LUMBER AND STEEL JOISTS, TRUSSES OR STRUCTURAL WOOD MEMBERS WITH BRIDGING AS REQUIRED WITH ENDS FIRESTOPPED. C. GYPSUM BOARD - NOM 4 FT (122 CM) WIDE BY 5/8" IN. (16MM) THICK AS SPECIFIED IN THE INDIVIDUAL FLOOR-CEILING DESIGN. GYPSUM BOARD NAILED TO WOOD JOISTS MAX DIA. OF CEILING OPENING IS 4 IN. (102 MM). A. POLYVINYL CHLORIDE (PVC) PIPE - NOM 3 IN. (76 MM) DIA. (OR SMALLER) SCHEDULE 40 SOLID OR CELLULAR CORE PVC PIPE FOR USE IN CLOSED (PROCESS OR SUPPLY) OR VENTED (DRAIN, WASTE OR VENT) PIPING SYSTEMS. B. ACRYLONITRILE BUTADIENE STYRENE (ABS) PIPE - NOM 3 IN. (76 MM) DIA. (OR SMALLER) SCHEDULE 40 SOLID OR CELLULAR-CORE ABS PIPE FOR USE IN CLOSED (PROCESS OR SUPPLY) OR VENTED (DRAIN, WASTE OR VENT) PIPING SYSTEMS. 3. FIRESTOP SYSTEM - THE FIRESTOP SYSTEM SHALL BE CONSIST OF THE FOLLOWING: A. PACKING MATERIAL - FOAM BACKER ROD FIRMLY PACKED INTO OPENING IN PLYWOOD FLOOR AS A PERMANENT FORM. PACKING MATERIAL TO BE RECESSED FROM TOP SURFACE OF SUB-FLOOR AS REQUIRED TO ACCOMMODATE THE REQUIRED THICKNESS OF FILL MATERIAL. B. FILL VOID OR CAVITY MATERIAL - WRAP STRIP NOM 0.13 IN (3.3 MM) THICK BY 2-3/8 IN. (60 MM) WIDE INTUMESCENT WRAP STRIP. THE WRAP STRIP IS CONTINUOUSLY WRAPPED FOUR TIMES AROUND THE OUTER CIRCUMFERENCE OF THE PIPE AT THE UNDERSIDE OF CEILING AND SECURED IN PLACE WITH 1-1/2 IN. (38 MM) WIDE ALUMINUM TAPE IN TREMCO INC TREMSTOP WS. C. STEEL COLLAR-COLLARS FABRICATED FROM PRECUT MIN. 0.016 IN. (0.4 MM) THICK (NO.28 GAUGE) GALV STEEL AVAILABLE FROM THE FILL MATERIAL MANUFACTURER. COLLAR SHALL BE NOM 2-1/2 IN. (64 MM) DEEP WITH 1 IN. (25MM) WIFE BY 2 IN. (51MM) LONG ANCHOR BOLT ON 2-1/4 IN. (57 MM) CENTERS FOR SECUREMENT TO THE WALL IN ADDITION, THE COLLAR CONTAINS RETAINER TABS, 3/8 TO 3/4 IN.(10 TO 19 MM) WIDE, ON BOTH SIDES OF THE COLLAR FOR RETAINING THE WRAPS STRIPS. THE COLLAR SHALL BE WRAPPED OVER THE WRAP STRIP, OVERLAPPED A MIN. 1 INCH (25MM) AND SECURED TOGETHER USING A MIN OF THREE NO. 6 BY 3/8 IN. ( 10 MM) SELF-DRILLING, SELF-TAPPING STEEL SCREWS OR USING ONE MIN 1/2 IN (13MM) WIDE BY 0.028 IN. (0.7MM) THICK STAINLESS STEEL HOSE CLAMP. THE RETAINING TABS ADJACENT TO THE ANCHOR TABS ARE BENT TOWARD THE PIPE AT ONE OR MORE LOCATIONS TO RETAIN WRAP STRIP. THE RETAINING TABS OPPOSITE THE ANCHOR TABS ARE FOLDED 90 DEGREES TOWARDS THE PIPE TO MAINTAIN THE ANNULAR SPACE AROUND THE PIPE AND TO RETAIN THE WRAP STRIP LAYERS. COLLAR IS SECURED TO THE GYPSUM BOARD SURFACE WITH 1/8 IN. (3MM) DIAM BY 1-1/2 IN. (38MM) DIAM FENDER WASHERS. ANCHORS TO BE USED IN EACH ANCHOR TAB OR AS DESCRIBED IN THE FOLLOWING. TWO ANCHORS, SYMMETRICALLY LOCATED, REQUIRED FOR NOM 1/2 IN. (13MM) TO NOM 2 IN. (51MM) DIAM PIPES. FOUR ANCHORS, SYMMETRICALLY LOCATED, REQUIRED FOR NOM 3 IN. (76MM) TO NOM 4 IN. (102 MM) DIAM PIPES.AS AN ALTERNATE TO (ITEMS 3B AND C) WRAP STRIP/STEEL COLLAR-FIRESTOP DEVICE - THE FIRESTOP DEVICE SHALL BE INSTALLED IN ACCORDANCE WITH THE ACCOMPANYING INSTALLATION INSTRUCTIONS. SEE ITEM 3B ABOVE FOR WRAP STRIPS REQUIRED WITHIN DEVICE. DEVICE WRAPPED AROUND THE PIPE AND SECURED BY USING THE ATTACHED HOSE CLAMP. DEVICE SLID ALONG THE PIPE UNTIL IT ABUTS THE BOTTOM OF THE CEILING. ANCHOR BOLTS TO BE USED WITH EVERY OTHER ANCHOR TAB WITH A MIN. OF TWO. DEVICE SECURED TO CEILING WITH MIN 1/8 IN. (3MM) DIAM BY 1-1/2 IN. (38MM) DIAM STEEL FENDER WASHERS. TREMCO INC- TREMSTOP -DD. FILL, VOID OR CAVITY MATERIAL - CAULK - MIN 1/2IN. (13MM) THICKNESS OF FILL MATERIAL APPLIED WITHIN THE ANNULUS, FLUSH WITH TOP SURFACE OF SUBFLOOR. ADDITIONAL FILL MATERIAL TO BE INSTALLED SUCH THAT A MIN 1/2 IN. (13MM) CROWN IS FORMED AROUND THE PIPE/SUBFLOOR. PIPE/COLLAR AND COLLAR/GYPSUM BOARD INTERFACES AND LAPPING 3/4I IN. (19MM) BEYOND THE PERIPHERY OF THE OPENING. THE TYPE OF FILL MATERIAL USED IS DEPENDENT ON THE SIZE OF NONMETALLIC PIPE (ITEM 2). FOR PIPES OF 2 IN. (51MM) DIAM OR SMALLER, ANY OF THE FILL MATERIALS INDICATED BELOW CAN BE USED. FIR PIPE DIAMS GREATER THAN 2 IN. (51MM), ONLY THE TREMSTOP INTUMESCENT ACRYLIC MAY BE USED.TREMCO INC. - TREMSTOP INTUMESCENT ACRYLIC, TREMSTOP ACRYLIC OR FYRE-SIL BEARING THE UL CLASSIFICATION MARK. WALL ASSEMBLY - THE 1 OR 2 HOUR FIRE - RATED GYPSUM BOARD STUD WALL ASSEMBLY SHALL BE CONSTRUCTED OF THE MATERIALS AND IN THE MANNER SPECIFIED IN THE INDIVIDUAL U300, U400 OR V400 SERIES WALL AND PARTITION DESIGNS IN THE UL FIRE RESISTANCE DIRECTORY AND SHALL INCLUDE THE FOLLOWING CONSTRUCTION FEATURES: A. STUDS - WALL FRAMING MAY CONSIST OF EITHER WOOD STUDS OR STEEL CHANNEL STUDS. WOOD STUDS TO CONSIST OF NOM 2 BY 4 IN. (51 BY 102 MM) LUMBER SPACED 16 IN. (406 MM) STEEL STUDS TO BE MIN 2-1/2 IN. (64 MM) WIDE AND SPACED MAX 24 IN. (610 MM) OC. B. GYPSUM BOARD - ONE OR TWO LAYERS OF NOM 1/2 OR 5/8 IN. (13 OR 16 MM) THICK GYPSUM BOARD AS SPECIFIED IN THE INDIVIDUAL WALL AND PARTITION DESIGN. MAX DIAM OF OPENING IS 15-1/8 IN. (384 MM). THE HOURLY F RATING OF THE FIRESTOP SYSTEM IS EQUAL TO THE HOURLY FIRE RATING OF THE WALL ASSEMBLY IN WHICH IT IS INSTALLED.STEEL SLEEVE - (OPTIONAL. NOT SHOWN.) CYLINDRICAL SLEEVE FABRICATED FROM MIN 0.013 IN. (0.330 MM) THICK (NO. 30 GAUGE) TO MAX 0.056 IN. (1.42 MM) (NO. 16 GAUGE) GALV STEEL SHEET AND HAVING A MIN. 1 IN. (25MM) LAP ALONG THE LONGITUDINAL SEAM. ENDS OF SLEEVE TO BE TRIMMED FLUSH WITH BOTH SURFACES OF WALL. SLEEVE TO BE INSTALLED BY COILING THE SHEET METAL TO A DIAM SMALLER THAN THE THROUGH OPENING, INSERTING THE COIL THROUGH THE OPENING AND RELEASING THE COIL TO LET IT UNCOIL AGAINST THE CIRCULAR CUTOUTS IN THE GYPSUM BOARD LAYERS.THROUGH PENETRANTS - ONE METALLIC PIPE, TUBING OR CONDUIT TO BE INSTALLED EITHER CONCENTRICALLY OR ECCENTRICALLY WITHIN THE FIRESTOP SYSTEM. PIPE, TUBING OR CONDUIT TO BE RIGIDLY SUPPORTED ON BOTH SIDES OF WALL ASSEMBLY AND SHALL BE PROVIDED WITH FLEXIBLE COUPLINGS WITHIN 1 FT. OF EACH SIDE OF WALL. THE PIPE, TUBING OR CONDUIT MAY BE INSTALLED AT AN ANGLE NOT GREATER THAN 45 DEGREES FROM THE PERPENDICULAR. THE ANNULAR SPACE SHALL BE MIN 0 (POINT CONTACT) IN. TO MAX 1-7/8 IN. (48 MM). THE FOLLOWING TYPES AND SIZES OF METALLIC PIPE TUBING OR CONDUIT MAY BE USED: A. STEEL PIPE - NOM 12 IN. (305 MM) DIAM (OR SMALLER) SCHEDULE 10 (OR HEAVIER) STEEL PIPE. B. IRON PIPE - NOM 12 IN. (305 MM) DIAM (OR SMALLER) CAST OR DUCTILE IRON PIPE. C. CONDUIT - NOM 4 IN. (102 MM) DIAM (OR SMALLER) STEEL ELECTRICAL METALLIC TUBING OR NOM 6 IN. DIAM (OR SMALLER) STEEL CONDUIT. D. COPPER TUBING - NOM 4 IN. (102 MM) DIAM (OR SMALLER) TYPE L (OR HEAVIER) COPPER TUBING. E. COPPER PIPE - NOM 4 IN. (102MM) DIAM (OR SMALLER) REGULAR (OR HEAVIER) COPPER PIPE. FIRESTOP SYSTEM - THE FIRESTOP SYSTEM SHALL CONSIST OF THE FOLLOWING: A. PACKAGING MATERIAL - (OPTIONAL) - FOAM BACKER ROD FIRMLY PACKED INTO THE OPENING A SA PERMANENT FORM. PACKING MATERIAL TO BE RECESSED FROM BOTH SURFACES OF WALL AS REQUIRED TO ACCOMMODATE THE REQUIRED THICKNESS OF FILL MATERIAL. B. FILL, VOID OR CAVITY MATERIAL - (CAULK) MIN 1/2 IN. (13MM). THE SURFACES OF WALL. WHEN ANNULAR SPACE EXCEEDS 1/2 IN. (13MM). THE MIN. THICKNESS OF FILL MATERIAL IS 5/8 IN. (16MM). ADDITIONAL FILL MATERIAL TO BE INSTALLED SUCH THAT A MIN 3/8 IN. (10MM) CROWN IS APPLIED AT THE PIPE/WALL INTERFACE AT THE POINT CONTACT LOCATION. TREMCO INC. - TREMSTOP INTUMESCENT ACRYLICBEARING THE UL CLASSIFICATION MARK 1. WALL ASSEMBLY - THE 1 OR 2 HR FIRE-RATED GYPSUM BOARD / STUD WALL ASSEMBLY SHALL BE CONSTRUCTED OF THE MATERIALS AND IN THE MANNER SPECIFIED IN THE INDIVIDUAL U300, U400 OR V400 SERIES WALL AND PARTITION DESIGNS IN THE UL FIRE RESISTANCE DIRECTORY AND SHALL INCLUDE THE FOLLOWING CONSTRUCTION FEATURES: A. STUDS - WALL FRAMING MAY CONSIST OF EITHER WOOD STUDS OR STEEL CHANNEL STUDS. WOOD STUDS TO CONSIST OF NOM 2 BY 4 IN. (51 BY 102 MM) LUMBER SPACED 16IN. (406 MM) OC. STEEL STUDS TO BE MIN 2-1/2 IN. (64MM) WIDE AND SPACED MAX 24 IN. (610 MM) OC. B. GYPSUM BOARD - 5/8 IN. (16MM) THICK, 4 FT (122 CM) WIDE WITH SQUARE OR TAPERED EDGES. THE GYPSUM BOARD TYPE, THICKNESS, NUMBER OF LAYERS, FASTENER TYPE AND SHEET ORIENTATION SHALL BE AS SPECIFIED IN THE INDIVIDUAL WALL AND PARTITION DESIGN. MAX DIAM OF OPENING IS 4 IN. (102MM).THE HOURLY F & T RATINGS OF THE FIRESTOP SYSTEM ARE EQUAL TO THE HOURLY FIRE RATING OF THE WALL ASSEMBLY IN WHICH IT IS INSTALLED UNLESS NOTED OTHERWISE. 2. THROUGH PENETRANTS - ONE NONMETALLIC PIPE TO BE INSTALLED EITHER CONCENTRICALLY OR ECCENTRICALLY WITHIN THE FIRESTOP SYSTEM. PIPE TO BE RIGIDLY SUPPORTED ON BOTH SIDES OF WALL ASSEMBLY AND SHALL BE PROVIDED WITH FLEXIBLE COUPLINGS WITHIN 1 FT. OF EACH SIDE OF WALL. THE FOLLOWING TYPES AND SIZES OF NONMETALLIC PIPES MAY BE USED: A. POLYVINYL CHLORIDE (PVC) PIPE - NOM 2 IN. (51 MM) DIAM (OR SMALLER) SCHEDULE 40 SOLID CORE PVC PIPE FOR USE IN CLOSED (PROCESS OR SUPPLY) OR VENTED (DRAIN, WASTE OR VENT) PIPING SYSTEMS. THE ANNULAR SPACE BETWEEN PIPE AND PERIPHERY OF OPENING SHALL BE MIN 9 IN. (POINT CONTACT) TO MAX 7/8 IN. (22 MM). FOR USE WITH 1 HR WALL CONSTRUCTIONS ONLY. WHEN USED, F RATING IS 1 HR AND T RATING IS 0 HR. B. POLYVINYL CHLORIDE (PVC) PIPE - NOM 2 IN. (51 MM) DIAM (OR SMALLER) SCHEDULE 40 SOLID CORE PVC PIPE FOR USE IN CLOSED (PROCESS OR SUPPLY) PIPING SYSTEMS. THE ANNULAR SPACE BETWEEN PIPE AND PERIPHERY OPENING SHALL BE MIN 1/4 IN. 6 MM) TO MAX 1-3/8 IN. (35MM). C. CHLORINATED POLYVINYL CHLORIDE (CPVC) PIPE - NOM 2 IN. (51 MM) DIAM (OR SMALLER) SDR 13.5 CPVC PIPE FOR USE IN CLOSED (PROCESS OR SUPPLY) PIPING SYSTEMS. THE ANNULAR SPACE BETWEEN PIPE AND PERIPHERY OF OPENING SHALL BE MIN 1/4 IN. (6MM) TO MAX 1-3/8 IN. (35 MM). D. ACRYLONITRILE BUTADIENE STYRENE (ABS) PIPE - NOM 2 IN. (51 MM) DIAM (OR SMALLER) SCHEDULE 40 SOLID-CORE ABS PIPE FOR USE IN CLOSED (PROCESS OR SUPPLY) OR VENTED (DRAIN, WASTE OR VENT) PIPING SYSTEMS. THE ANNULAR SPACE BETWEEN PIPE NAD PERIPHERY OF OPENING SHALL BE MIN 1/4 IN. (6 MM) TO MAX 7/8 IN. (22 MM). E. CROSSLINKED POLYETHYLENE (PEX) TUBE - NOM 1 IN. (25 MM) DIAM (OR SMALLER) SDR 9 PEX TUBING FOR USE IN CLOSED (PROCESS OR SUPPLY) PIPING SYSTEMS. THE ANNULAR SPACE BETWEEN TUBE AND PERIPHERY OF OPENING SHALL BE MIN 1/4 IN. (6 MM) TO MAX 1-3/8 IN. (35 MM). F. RIGID NONMETALLIC CONDUIT + - NOM 2 IN. (51 MM) DIAM (OR SMALLER)M SCHEDULE 40 PVC CONDUIT INSTALLED IN ACCORDANCE WITH ARTICLE 347 OF THE NATIONAL ELECTRICAL CODE (NFPA NO. 70). THE ANNULAR SPACE BETWEEN CONDUIT AND PERIPHERY OF OPENING SHALL BE MIN 1/4 IN. (6 MM) TO MAX 1-3/8 IN. (35 MM). G. CHLORINATED POLYVINYL CHLORIDE (CPVC) PIPE - NOM 2IN. DIAM (OP SMALLER) FLOWGUARD GOLD SDR 11 CPVC FOR USE IN CLOSED (PROCESS OR SUPPLY) PIPING SYSTEMS. THE ANNULAR SPACE BETWEEN CONDUIT AND PERIPHERY OF OPENING SHALL BE MIN 1/4 IN. (6 MM) TO MAX 1-3/8 IN. (35 MM) H. CHLORINATED POLYVINYL (CPVC) PIPE - NOM 2 IN. DIAM (OR SMALLER) BLAZEMASTER SDR 13.5 CPVC FOR USE IN CLOSED (PROCESS OR SUPPLY) PIPING SYSTEMS. THE ANNULAR SPACE BETWEEN CONDUIT AND PERIPHERY OF OPENING SHALL BE MIN 1/4 IN. (6 MM) TO MAX 1-3/8 IN. (35 MM). 3. FIRESTOP SYSYTEM - THE FIRESTOP SYSTEM SHALL CONSIST OF THE FOLLOWING: A. PACKING MATERIAL - (OPTIONAL) IN 2HR WALL ASSEMBLIES, FOAM BACKER ROD FIRMLY PACKED INTO OPENING AS A PERMANENT FORM. PACKING MATERIAL TO BE PROCESSED FROM BOTH SURFACES OF WALL AS REQUIRED TO ACCOMMODATE THE REQUIRED THICKNESS OF FILL MATERIAL. B. FILL, VOID OR CAVITY MATERIAL - CAULK - MIN 5/8 IN. (16 MM) THICKNESS OF FILL MATERIAL APPLIED WITHIN THE ANNULUS, FLUSH WITH BOTH SURFACES OF WALL. ADDITIONAL FILL MATERIAL TO BE INSTALLED SUCH THAT A MIN 1/4 IN. (6 MM) CROWN IS FORMED AROUND THE PENETRATING ITEM. TREMCO INC. - TREMSTOP INTUMESCENT ACRYLICBEARING THE UL CLASSIFICATION MARK 1. FLOOR - CEILING ASSEMBLY - THE FIRE-RATED WOOD JOIST FLOOR - CEILING ASSEMBLY SHALL BE CONSTRUCTED OF THE MATERIALS AND IN THE MANNER SPECIFIED IN THE INDIVIDUAL L500 SERIES FLOOR-CEILING DESIGNS IN THE UL FIRE RESISTANCE DIRECTORY, AS SUMMARIZED BELOW: A. FLOORING SYSTEM - LUMBER OR PLYWOOD SUBFLOOR WITH FINISH FLOOR OF LUMBER, PLYWOOD OR FLOOR TOPPING MIXTURE AS SPECIFIED IN THE INDIVIDUAL FLOOR-CEILING DESIGN. MAX DIAM OF FLOOR OPENING IS 4 IN. (102 MM). B. WOOD JOISTS - NOM 2 BY 10 IN. (51 BY 254 MM) LUMBER JOISTS SPACED 16 IN. (406 MM) OC WITH NOM 1 BY 3 IN. (25 BY 76 MM) LUMBER BRIDGING AND WITH ENDS FIRESTOPPED. AS AN ALTERNATE TO LUMBER JOISTS, NOM 10 IN. (254 MM) DEEP (OR DEEPER) LUMBER, STEEL OR COMBINATION LUMBER AND STEEL JOISTS, TRUSSES OR STRUCTURAL WOOD MEMBERS WITH BRIDGING AS REQUIRED WITH ENDS FIRESTOPPED. C. GYPSUM BOARD - NOM 4 FT (122 CM) WIDE BY 5/8 IN. (16 MM) THICK AS SPECIFIED IN THE INDIVIDUAL FLOOR-CEILING DESIGN. GYPSUM BOARD NAILED TO WOOD JOISTS. MAX DIAM OF CEILING OPENING IS 4 IN. (102 MM). 2. THROUGH PENETRANTS - ONE NONMETALLIC PIPE TO BE INSTALLED EITHER CONCENTRICALLY OR ECCENTRICALLY WITHIN THE FIRESTOP SYSTEM. PIPE TO BE RIGIDLY SUPPORTED ON BOTH SIDES OF FLOOR-CEILING ASSEMBLY. THE SPACE BETWEEN PIPE AND PERIPHERY OF OPENING SHALL BE MIN O IN. (POINT CONTACT) TO MAX 1/2 IN. (13 MM). THE FOLLOWING TYPES AND SIZES OF NONMETALLIC PIPES MAY BE USED: A. POLYVINYL CHLORIDE (PVC) PIPE - NOM 3 IN. (76 MM) DIAM (OR SMALLER) SCHEDULE 40 SOLID OR CELLULAR-CORE PVC PIPE FOR USE IN CLOSED (PROCESS OR SUPPLY) OR VENTED (DRAIN, WASTE OR VENT) PIPING SYSTEMS. B. ACRYLONITRILE BUTADIENE STYRENE (ABS) PIPE - NOM 3 IN. (76 MM) DIAM (OR SMALLER) SCHEDULE 40 SOILD OR CELLULAR-CORE ABS PIPE FOR USE IN CLOSED (PROCESS OR SUPPLY) OR VENTED (DRAIN, WASTE R VENT) PIPING SYSTEMS. 3. FIRESTOP SYSTEM - THE FIRESTOP SYSTEM SHALL CONSIST OF THE FOLLOWING: A. PACKING MATERIAL - FOAM BACKER ROD FIRMLY PACKED INTO OPENING IN PLYWOOD FLOOR AS A PERMANENT FORM. PACKING MATERIAL TO BE RECESSED FROM TOP SURFACE OF SUBFLOOR AS REQUIRED TO ACCOMMODATE THE REQUIRED THICKNESS OF FILL MATERIAL. B. FILL, VOID OR CAVITY MATERIAL -WRAP STRIP - NOM 0.13 IN. (3.3 MM) THICK BY 2-3/8 IN. (60 MM) WIDE INTUMESCENT WRAP STRIP. THE WRAP STRIP IS CONTINUOUSLY WRAPPED FOUR TIMES AROUND THE OUTER CIRCUMFERENCE OF THE PIPE AT THE UNDERSIDE OF CEILING AND SECURED IN PLACE WITH 1-1/2 IN. (38 MM) WIDE ALUMINUM TAPE.TREMCO INC - TREMSTOP -WS C. STEEL COLLAR - COLLARS FABRICATED FROM PRECUT MIN 0.016 IN. (0.4 MM) THICK (NO.28 GAUGE) GALV STEEL AVAILABLE FROM THE FILL MATERIAL MANUFACTURER. COLLAR SHALL BE NOM. 2-1/2 IN. (64 MM) DEEP WITH 1 IN. (25 MM) WIDE BY 2 IN. (51 MM) LONG ANCHOR TABS ON 2-1/4 IN. (57 MM) CENTERS FOR SECUREMENT TO THE WALL. IN ADDITION, THE COLLAR CONTAINS RETAINER TABS. 3/8 TO 3/4 IN. (10 TO 19 MM) WIDE, ON BOTH SIDES OF THE COLLAR FOR RETAINING THE WRAP STRIPS. THE COLLAR SHALL BE WRAPPED OVER THE WRAP STRIP, OVERLAPPED A MIN 1 IN. (25 MM) AND SECURED TOGETHER USING A MIN OF THREE NO. 6 BY 3/8 IN. (10 MM) SELF-DRILLING, SELF TAPPING STEEL SCREWS OR USING ONE MIN 1/2 IN. (13 MM) WIDE BY 0.028 IN. (0.7 MM) THICK STAINLESS STEEL HOSE CLAMP. THE RETAINING TABS ADJACENT TO THE ANCHOR TABS ARE BENT TOWARD THE PIPE TO MAINTAIN THE ANNULAR SPACE AROUND THE PIPE AND TO RETAIN THE WRAP STRIP LAYERS. COLLAR IS SECURED TO THE GYPSUM BOARD SURFACE WITH 1/8 IN. (3 MM) DIAM BY 1-1/2 IN. (38 MM) LONG HOLLOW WALL ANCHORS IN CONJUNCTION WITH MIN 1-1/2 IN. (38 MM) DIAM FENDER WASHERS. ANCHORS TO BE USED IN EACH ANCHOR TAB OR AS DESCRIBED IN THE FOLLOWING. TWO ANCHORS, SYMMETRICALLY LOCATED, REQUIRED FRO NOM 1/2 IN. (13 MM) TO NOM 2 IN. (51 MM) DIAM PIPES. FOUR ANCHORS, SYMMETRICALLY LOCATED, REQUIRED FOR NOM 3 IN. (76 MM) TO NOM 4 IN. (102 MM) DIAM PIPES.AS AN ALTERNATE TO (ITEMS 3B AND C) WRAP STRIP/STEEL COLLAR-FIRESTOP DEVICE - THE FIRESTOP DEVICE SHALL BE INSTALLED IN ACCORDANCE WITH THE ACCOMPANYING INSTALLATION INSTRUCTIONS. SEE ITEM 3B ABOVE FOR WRAP STRIPS REQUIRED WITHIN DEVICE. DEVICE WRAPPED AROUND THE PIPE AND SECURED BY USING THE ATTACHED HOSE CLAMP. DEVICE SLID ALONG THE PIPE UNTIL IT ABUTS THE BOTTOM OF THE CEILING. ANCHOR BOLTS TO BE USED WITH EVERY OTHER ANCHOR TAB WITH A MIN OF TWO. DEVICE SECURED TO CEILING WITH A MIN 1/8 IN. (3 MM) DIAM BY 1-1/2 IN. (38 MM) DIAM STEEL FENDER WASHERS.TREMCO INC - TREMSTOP - D D. FILL, VOID OR CAVITY MATERIAL - CAULK - MIN 1/2 IN. (13 MM) THICKNESS OF ILL MATERIAL APPLIED WITHIN THE ANNULUS, FLUSH WITH TOP SURFACE OF SUBFLOOR. ADDITIONAL FILL MATERIAL TO BE INSTALLED SUCH THAT A MIN 1/2 IN. (13 MM) CROWN IS FORMED AROUND THE PIPE/SUBFLOOR. PIPE/COLLAR AND COLLAR/GYPSUM BOARD INTERFACES AND LAPPING 3/4 IN. (19 MM) BEYOND THE PERIPHERY OF THE OPENING. THE TYPE OF FILL MATERIAL USED IS DEPENDENT ON THE SIZE OF NON METALLIC PIPE (ITEM 2). INDICATED BELOW CAN BE USED. FOR PIPE DIAM GREATER THAN 2 IN. (51 MM) ONLY THE TREMSTOP INTUMESCENT ACRYLIC MAY BE USED.TREMSTOP INC - TREMSTOP INTUMESCENT ACRYLIC. TREMSTOP ACRYLIC OR FYRE-SIL BEARING THE UL CLASSIFICATION MARK PENETRATIONS IN A WALL MAX. 2" PVC & CPVC SCH 40MAX. 11/2" PVC & CPVC SCH 40MAX. 1' PEXELECTRICAL WIRES (5)4" STEEL OR CAST IRON MAX. OPENING SIZE 4"3"2"1 1/2"51/2" x 6" THROUGH-PENETRATIONS 1 PEXELECTRICAL WIRES 2" COPPER1 1/2' EMT1 1/2" COPPER MAX OPENING SIZE 2"21/4" 3" x 33"3" 1. FLOOR - 1 HOUR RATED FLOOR/CEILING ASSEMBLY FRAMED WITH NOMINAL 2" x 10" JOISTS. 2. WALL - RATED OR NONRATED WALL ASSEMBLY FRAMED WITH NOMINAL 2" X 4" WOOD/STEEL STUDS FACED WITH GYPSUM WALLBOARD. 3. PENETRATING ITEMS - SEE TABLE ABOVE. T RATING FOR NON METALLIC PENETRATIONS - 1 HOUR, EXCEPT CPVC - T RATING 45 MINUTES. T RATING FOR METALLIC PENETRATIONS - 60 MINUTES. ELECTRICAL BUNDLE CONSISTS OF TO 5 LOOMEX 1 4/2 WIRES OR 4 LOOMEX 14/2 WIRES AND A 1" DIAMETER TEK CABLE. 4. FIRE STOP CAULK - TREMCO FYRE-SIL APPLIED TO A DEPTH OF 5/8" WHERE PENETRATION PASSES THROUGH FLOOR OR CEILING MEMBRANE, OR THROUGH HEADER OR SOLE PLATES OF WALL ASSEMBLY. 5. FIRESTOP CAULK - TREMCO FYRE-SIL APPLIED TO A DEPTH OF 5/8" WHERE PENETRATION PASSES THROUGH FLOOR OR CEILING MEMBRANE, OR THROUGH HEADER OR SOLE PLATES OF WALL ASSEMBLY. 6. GYPSUM WALLBOARD - SEAL FOR 10" X 10" OPENING, 5/8" TYPE X SCREWED TO UNDERSIDE OF PLYWOOD. MAXIMUM 2-1/2" HOLE. ANNULAR SPACE AROUND PIPE SEALED WITH FYRE-SILT DEPTH OF THE MEMBRANE. 1. FLOOR - CEILING ASSEMBLY - THE 2 HR FIRE-RATED WOOD JOIST FLOOR-CEILING ASSEMBLY SHALL BE CONSTRUCTED OF THE MATERIALS AND IN THE MANNER SPECIFIED IN DESIGN NOS. L505, L511 OR L536 IN THE UL FIRE RESISTANCE DIRECTORY. THE GENERAL CONSTRUCTION FEATURES OF THE FLOOR-CEILING ASSEMBLY ARE SUMMARIZED BELOW: A. WOOD JOISTS - NOM 2 BY 10 IN. (51 BY 254 MM) LUMBER JOISTS SPACED 16 IN. (406 MM) OC WITH NOM 1 BY 3 IN. (25 BY 76 MM) LUMBER BRIDGING AND WITH ENDS FIRESTOPPED. B. FLOORING SYSTEM - LUMBER OR PLYWOOD SUBFLOOR WITH FINISH FLOOR OF LUMBER, PLYWOOD OR FLOOR TOPPING MIXTURE AS SPECIFIED IN THE INDIVIDUAL FLOOR-CEILING DESIGN. MAX DIAM OF FLOOR OPENING IS 3 IN. (76 MM). C. FURRING CHANNELS - RESILIENT GALV STEEL FURRING CHANNELS INSTALLED PERPENDICULAR TO WOOD JOISTS BETWEEN FIRST AND SECOND LAYERS OF GYPSUM BOARD (ITEM ID). FURRING CHANNELS SPACED MAX 24 IN. (610 MM) OC. D. GYPSUM BOARD - NOM 4 FT (122 CM) WIDE BY 5/8 IN. (16 MM) THICK AS SPECIFIED IN THE INDIVIDUAL FLOOR-CEILING DESIGN. SECOND LAYER OF GYPSUM BOARD SCREW-ATTACHED TO FURRING CHANNELS AS SPECIFIED IN THE INDIVIDUAL FLOOR-CEILING DESIGN. MAX DIAM OF CEILING OPENING IS 3 IN. (76 MM) 1.1 CHASE WALL - (NOT SHOWN, OPTIONAL) THE THROUGH PENETRANT (ITEM 2) MAY BE ROUTED THROUGH A 2 HR FIRE RATED SINGLE, DOUBLE OR STAGGERED WOOD STUD/ GYPSUM WALLBOARD CHASE WALL CONSTRUCTED OF THE MATERIALS AND IN THE MANNER SPECIFIED IN THE INDIVIDUAL U300 SERIES WALL AND PARTITION DESIGNS IN THE UL FIRE RESISTANCE DIRECTORY AND SHALL INCLUDE THE FOLLOWING CONSTRUCTION FEATURES: A. STUDS - NOM 2 BY 6 IN. (51 BY 152 MM) LUMBER STUDS. B. SOLE PLATE - NOM 2 BY 6 IN. (51 BY 152 MM) LUMBER PLATES. MAX DIAM OF OPENING IS 3 IN. (76 MM). C. TOP PLATE - THE DOUBLE TOP PLATE SHALL CONSIST OF TWO NOM 2 BY 6 IN. (51 BY 152 MM) LUMBER PLATES. MAX DIAM OF OPENING IS 3 IN. (76 MM). D. GYPSUM BOARD - THICKNESS, TYPE, NUMBER OF LAYERS AND FASTENERS SHALL BE AS SPECIFIED IN INDIVIDUAL WALL AND PARTITION DESIGN. 2. CABLES - AGGREGATE CROSS-SECTIONAL AREA OF CABLES IN OPENING TO BE MAX 44 PERCENT OF THE AGGREGATE CROSS SECTIONAL AREA OF THE OPENING. THE ANNULAR SPACE BETWEEN THE CABLE BUNDLE AND THE PERIPHERY OF THE OPENING SHALL BE MIN 1/4 IN. (6 MM) TO MAX 1/2 IN. (13 MM). CABLES TO BE RIGIDLY SUPPORTED ON BOTH SIDES OF FLOOR ASSEMBLY, ANY COMBINATION OF THE FOLLOWING TYPES AND SIZES OF COPPER CONDUCTOR CABLES MAY BE USED: A. MAX 200 PAIR NO. 24 AWG (OR SMALLER) COPPER CONDUCTOR CABLE WITH POLYVINYL CHLORIDE (PVC) INSULATION AND JACKET. B. RG59/U (OR SMALLER) COAXIAL CABLE WITH FLUORINATED ETHYLENE (FE) OR PVC INSULATION AND JACKET. C. MAX 4 PAIR NO. 24 AWG (OR SMALLER) COPPER CONDUCTOR DATA CABLE WITH HYLAR JACKET AND INSULATION. D. MAX THREE CONDUCTOR WITH GROUND NO. 12 AWG (OR SMALLER) NONMETALLIC SHEATHED (ROMEX) CABLES WITH PVC INSULATION AND JACKET MATERIALS. E. THROUGH PENETRATING PRODUCT - TWO OR MORE TWISTED COPPER CONDUCTORS N0. 10 AWG (OR SMALLER) POWER LIMITED FIRE ALARM CABLE + WITHOUT A JACKET UNDERA METAL ARMOR.AFC CABLE SYSTEMS INC F. THROUGH PENETRATING PRODUCT - TWO OR MORE TWISTED COPPER CONDUCTORS NO. 12 AWG (OR SMALLER) NON POWER LIMITED FIRE ALARM CABLE + WITH OR WITHOUT A JACKET UNDER A METAL ARMOR.AFC CABLE SYSTEMS INC. G. THROUGH PENETRATING PRODUCT - MAX TWO COPPER CONDUCTORS WITH GROUND NO. 12 AWG (OR SMALLER) METAL-CLAD CABLE+.AFC CABLE SYSTEMS INC. H. THROUGH PENETRATING PRODUCT - NOM 3/4 IN. (19MM) DIAM (OR SMALLER) ALUMINUM OR STEEL FLEXIBLE METAL CONDUIT + WITH ELECTRICAL CONDUCTORS AS PERMITTED BY THE NATIONAL ELECTRICAL CODE (NFPA 70).AFLEX CORP I. MAX FOUR ALUMINUM CONDUCTOR NO 2/0 AWG (OR SMALLER) TYPE SER SERVICE ENTRANCE CABLE WITH CROSS-LINKED POLYETHYLENE INSULATION AND PVC JACKET.THE T RATING IS 2 HR EXCEPT THAT THE T RATING FOR ITEM A IS 1-3/4 HR AND THE T RATING FOR ITEMS H AND I IS O HR. 3. FIRESTOP SYSTEM - THE FIRESTOP SYSTEM CONSISTS OF THE FOLLOWING ITEMS: A. PACKING MATERIAL - (OPTIONAL) FOAM BACKER ROD FIRMLY PACKED INTO OPENING AS A PERMANENT FORM AND RECESSED FROM TOP SURFACE OF FLOOR OR SOLE PLATE AND BOTTOM SURFACE OF CEILING OR LOWER TOP PLATE OF CHASE WALL ASSEMBLY TO ACCOMMODATE REQUIRED THICKNESS OF FILL MATERIAL. B. FILL, VOID OR CAVITY MATERIAL - CAULK - MIN 5/8 IN. (16 MM) THICKNESS OF FILL MATERIAL APPLIED WITHIN THE ANNULUS, FLUSH WITH TOP SURFACE OF THE FLOOR OR SOLE PLATE AND BOTTOM SURFACE OF THE CEILING OR LOWER TOP PLATE OF CHASE WALL ASSEMBLY. ADDITIONAL FILL MATERIAL TO BE FORCED INTO INTERSTICES OF CABLE GROUP TO MAX EXTENT POSSIBLE CROWN IS FORMED AROUND THE CABLE GROUP AND LAPPING 1/2 IN. (13 MM) BEYOND THE PERIPHERY OF THE OPENING.TREMCO INC - TREMSTOP INTUMESCENT ACRYLICBEARING THE UL CLASSIFICATION MARK+ BEARING THE UL LISTING MARK FIRE PENETRATION DETAILS 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216FIRE PENETRATIONDETAILS A-512 FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV Revision Schedule Number Description Date INTERIOREXTERIOR 5/8" EXTERIOR GWB (DENSGLAS OR SIMILAR) VAPOR BARRIER XE1 - EIFS FINISH: NO SHEAR 2" EIFS SYSTEM LAYER TYPE X 5/8" GYPSUM WALL BD. FLOOR AND BASE FIN. AS SCHEDULE AIR BARRIER 2" X 6" WOOD STUD, 16" O.C, FILLED WITH FIBERGLASS BATT INSULATION COLORS A-E: SEE GRAPHIC LEGENDCODE MIN R-VALUE: R:20 STD + R3.8 CIR-VALUE: R-20 STUD + R-8.6 CIUL DESIGN: U349FIRE RATING: 2 HOURS FROM EXTERIOR, 1 HOUR FROM INTERIORSTC RATING: 50 (EXTRAPOLATED)STC TEST: NGC 2015085HEIGHT: CONTINUOUS FOUNDATION INTERIOREXTERIOR 5/8" FIRE-RATED PLYWOOD SHEATHING PER STRUCTURAL VAPOR BARRIER XE2 - EIFS FINISH: SINGLE SHEAR 2" EIFS SYSTEM FLOOR AND BASE FIN. AS SCHEDULE AIR BARRIER 2" X 6" WOOD STUD, 16" O.C, FILLED WITH FIBERGLASS BATT INSULATION COLORS A-E: SEE GRAPHIC LEGENDCODE MIN R-VALUE: R:20 STD + R3.8 CIR-VALUE: R-20 STUD + R-8.8 CIUL DESIGN: U349FIRE RATING: 2 HOURS FROM EXTERIOR, 1 HOUR FROM INTERIORSTC RATING: 50 (EXTRAPOLATED)STC TEST: NGC 2015085HEIGHT: CONTINUOUSMIN.0' - 6"FOUNDATION /10 A-509/11 A-509 MIN.0' - 2"PAVEMENT /3 A-509SIM INTERIOR EXTERIOR 5/8" FIRE-RATED PLYWOOD SHEATHING PER STRUCTURAL EITHER SIDE VAPOR BARRIER XE3 - EIFS FINISH: DOUBLE SHEAR 2" EIFS SYSTEMLAYER TYPE X 5/8" ACOUSTIC GYPSUM WALL BD. FLOOR AND BASE FIN. AS SCHEDULE AIR BARRIER 2" X 6" WOOD STUD, 16" O.C, FILLED WITH FIBERGLASS BATT INSULATION COLORS A-E: SEE GRAPHIC LEGENDCODE MIN R-VALUE: R:20 STD + R3.8 CIR-VALUE: R-20 STUD + R-8.8 CIUL DESIGN: U349FIRE RATING: 2 HOURS FROM EXTERIOR, 1 HOUR FROM INTERIORSTC RATING: 50 (EXTRAPOLATED)STC TEST: NGC 2015085HEIGHT: CONTINUOUS MIN.0' - 6"FOUNDATION /10 A-509 LAYER TYPE X 5/8" ACOUSTIC GYPSUM WALL BD. LAYER TYPE X 5/8" GYPSUM WALL BD. LAYER TYPE X 5/8" ACOUSTIC GYPSUM WALL BD. ELEVATOR EXTERIOR 5/8" FIRE-RATED PLYWOOD SHEATHING PER STRUCTURAL VAPOR BARRIER XE4 - EIFS FINISH: NO SHEAR @ ELEVATOR 2" EIFS SYSTEM2 LAYERS TYPE X 1" GYPSUM WALL BD. SHAFT LINER FLOOR AND BASE FIN. AS SCHEDULE AIR BARRIER 2" X 6" WOOD STUD, 16" O.C, FILLED WITH FIBERGLASS BATT INSULATION COLORS A-E: SEE GRAPHIC LEGENDCODE MIN R-VALUE: R:20 STD + R3.8 CIR-VALUE: R-21.6 STUD + R-8.8 CIUL DESIGN: U349FIRE RATING: 2 HOURS FROM EXTERIOR, 1 HOUR FROM INTERIORSTC RATING: 50 (EXTRAPOLATED)STC TEST: NGC 2015085HEIGHT: CONTINUOUS MIN.0' - 6"FOUNDATION /10 A-509 /3 A-509SIM H CHANNEL, 24" O.C. 3/4" AIR SPACE 0' - 9 1/2"0' - 9 1/2"0' - 9 1/2"0' - 11" INTERIOR EXTERIOR XE5 - EIFS FINISH: STORAGE ROOM 2" EIFS SYSTEM FLOOR AND BASE FIN. AS SCHEDULE VAPOR BARRIER NOMINAL 8" CMU WALL. PAINTED INTERIOR WALLS COLORS A-E: SEE GRAPHIC LEGENDCODE MIN R-VALUE: LOW ENERGY BUILDING- NOT REQUIREDR-VALUE: R-15.5 CIUL DESIGN: U907FIRE RATING: 3 HOURSSTC RATING: 51STC TEST: HUD LISTINGHEIGHT: CONTINUOUS FOUNDATION /11 A-509 MIN.0' - 2"PAVEMENT /3 A-509SIM INTERIOREXTERIOR XE6 - EIFS FINISH: TRASH ENCLOSURE THINSET EIFS SYSTEM VAPOR BARRIER NOMINAL 8" CMU WALL. PAINTED INTERIOR WALLS COLORS A-E: SEE GRAPHIC LEGENDCODE MIN R-VALUE: NOT REQUIREDR-VALUE: R-7.5 CIUL DESIGN: U907FIRE RATING: 3 HOURSSTC RATING: 45STC TEST: HUD LISTINGHEIGHT: CONTINUOUS FOUNDATIONPAVEMENT INTERIOREXTERIOR XE7 - EIFS FINISH: TRASH ENCLOSURE THINSET EIFS SYSTEM VAPOR BARRIER NOMINAL 4" CMU WALL. PAINTED INTERIOR WALLS COLORS A-E: SEE GRAPHIC LEGENDCODE MIN R-VALUE: NOT REQUIREDR-VALUE: R-3.75 CIUL DESIGN: U907FIRE RATING: 3 HOURSSTC RATING: 40STC TEST: HUD LISTINGHEIGHT: CONTINUOUS FOUNDATIONPAVEMENT EXTERIOR EXTERIOR 5/8" EXTERIOR GWB (DENSGLAS OR SIMILAR) VAPOR BARRIER XE8 - EIFS FINISH: DOUBLE SIDED WING WALL THINSET EIFS SYSTEM 5/8" EXTERIOR GWB (DENSGLAS OR SIMILAR) AIR BARRIER 2" X 6" WOOD STUD, 16" O.C, FILLED WITH FIBERGLASS BATT INSULATION COLORS A-E: SEE GRAPHIC LEGENDCODE MIN R-VALUE: NOT REQUIREDR-VALUE: NOT REQUIREDUL DESIGN: U349FIRE RATING: 2 HOURS FROM EXTERIOR, 1 HOUR FROM INTERIORSTC RATING: N/ASTC TEST: N/AHEIGHT: CONTINUOUS FOUNDATION VAPOR BARRIER AIR BARRIER ROOF XE9 - EIFS FINISH: PARAPET 2" EIFS SYSTEM 5/8" EXTERIOR GWB (DENSGLAS OR SIMILAR) 2" X 6" WOOD STUD, 16" O.C, FILLED WITH FIBERGLASS BATT INSULATION COLORS A-E: SEE GRAPHIC LEGENDCODE MIN R-VALUE: NOT REQUIREDR-VALUE: NOT REQUIREDUL DESIGN: U349FIRE RATING: 1 HOURSTC RATING: N/ASTC TEST: N/AHEIGHT: CONTINUOUS EXTERIOR 5/8" EXTERIOR GWB (DENSGLAS OR SIMILAR) VAPOR BARRIER AIR BARRIER VAPOR BARRIER AIR BARRIER TPO ROOFING PARAPET CAP THINSET EIFS SYSTEM SIM 0' - 7 3/4"0' - 3 3/4"0' - 6 3/4"0' - 8 3/4" XE-A / PT-A / PC-ABEIGE EIFS/MATCH SHERWIN-WILLIAMSPAINT / POWDER-COAT SW6154 NACRE (263-C2) XE-B / PT-B / PC-BLIGHT BROWN EIFS / MATCH SHERWIN-WILLIAMSPAINT / POWDER-COAT SW7153 SANDERLING (248-C5) GRAPHIC EXTERIOR MATERIAL LEGEND XE-C / PT-C / PC-CMID BROWN EIFS /MATCH SHERWIN-WILLIAMSPAINT / POWDER-COAT SW7525 TREE BRANCH (288-C7) XE-D / PT-D / PC-DRED BROWN EIFS / MATCH SHERWIN-WILLIAMSPAINT / POWDER-COAT SW6118 LEATHER BOUND (291-C7) XE-E / PT-E / PC-EDARK BROWN EIFS / MATCH SHERWIN-WILLIAMSPAINT / POWDER-COAT SW7510 CHATEAU BROWN (242-C7) XS-FMANUFACTURED STONE CULTURED STONE VENEER CLADDING COUNTRY LEDGESTONEASHFALL XW-G / WD-1 WOOD-LOOK KNOTWOOD, 6" CLADDINGALUMINUM CLADDING WESTERN RED CEDAR 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216EXTERIOR WALL TYPES- EIFS A-513 FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 0'4" 8"1' 4" SCALE: 1 1/2" = 1'-0" EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV Revision Schedule Number Description Date INTERIOREXTERIOR 5/8" EXTERIOR GWB (DENSGLAS OR SIMILAR) VAPOR BARRIER XS1 - STONE FINISH: NO SHEAR LAYER TYPE X 5/8" GYPSUM WALL BD. FLOOR AND BASE FIN. AS SCHEDULE AIR BARRIER 2" X 6" WOOD STUD, 16" O.C, FILLED WITH FIBERGLASS BATT INSULATION COLOR F: SEE GRAPHIC LEGENDCODE MIN R-VALUE: R:20 STD + R3.8 CIR-VALUE: R-20 STUD + R-5.6 CIUL DESIGN: U349FIRE RATING: 2 HOURS FROM EXTERIOR, 1 HOUR FROM INTERIORSTC RATING: 50 (EXTRAPOLATED)STC TEST: NGC 2015085HEIGHT: CONTINUOUS FOUNDATIONPAVEMENT INTERIOREXTERIOR 5/8" FIRE-RATED PLYWOOD SHEATHING PER STRUCTURAL EITHER SIDE VAPOR BARRIER LAYER TYPE X 5/8" ACOUSTIC GYPSUM WALL BD. FLOOR AND BASE FIN. AS SCHEDULE AIR BARRIER 2" X 6" WOOD STUD, 16" O.C, FILLED WITH FIBERGLASS BATT INSULATION LAYER TYPE X 5/8" ACOUSTIC GYPSUM WALL BD. EXTERIOREXTERIOR 1/2" CEMENT BOARD VAPOR BARRIER XE6 - STONE FINISH: DOUBLE-SIDED SOLID SURFACE 1/2" CEMENT BOARD AIR BARRIER 2" X 4" WOOD STUD, 16" O.C COLOR: SEE ENLARGED KITCHEN DRAWINGSCODE MIN R-VALUE: NOT REQUIREDR-VALUE: NOT REQUIREDUL DESIGN: U349FIRE RATING: 1 HOURSTC RATING: N/ASTC TEST: N/AHEIGHT: CONTINUOUS FOUNDATION VAPOR BARRIER AIR BARRIER0' - 2"1" RIGID XPS INSULATION FOUNDATION WEEP SCREED XS2 - STONE FINISH: DOUBLE SHEAR COLOR F: SEE GRAPHIC LEGENDCODE MIN R-VALUE: R:20 STD + R3.8 CIR-VALUE: R-20 STUD + R-5.8 CIUL DESIGN: U349FIRE RATING: 2 HOURS FROM EXTERIOR, 1 HOUR FROM INTERIORSTC RATING: 50 (EXTRAPOLATED)STC TEST: NGC 2015085HEIGHT: CONTINUOUS +/- 0' - 10 1/2" MANUFACTURED STONE VENEER OVER MORTAR SCRATCH AND SETTING BEDS 0' - 6 1/4"1" RIGID XPS INSULATION FOUNDATION WEEP SCREED FOUNDATION +/- 0' - 10 1/2" INTERIOR EXTERIOR 5/8" FIRE-RATED PLYWOOD SHEATHING PER STRUCTURAL WHERE REQUIRED VAPOR BARRIER LAYER TYPE X 5/8" ACOUSTIC GYPSUM WALL BD. FLOOR AND BASE FIN. AS SCHEDULE AIR BARRIER 2" X 8" STEEL MOMENT FRAME, 16" O.C, FILLED WITH FIBERGLASS BATT INSULATION XS3 - STONE FINISH: NO SHEAR, POOL ROOM COLOR F: SEE GRAPHIC LEGENDCODE MIN R-VALUE: R:20 STD + R3.8 CIR-VALUE: R-20 STUD + R-5.6 CIUL DESIGN: U349FIRE RATING: 2 HOURS FROM EXTERIOR, 1 HOUR FROM INTERIORSTC RATING: 53 (EXTRAPOLATED)STC TEST: NGC 2015085HEIGHT: CONTINUOUS MIN.0' - 6"1" RIGID XPS INSULATION FOUNDATION WEEP SCREED FOUNDATION +/- 1' - 0 1/2" EXTERIOR EXTERIOR VAPOR BARRIER 2 LAYERS 5/8" EXTERIOR GWB (DENSGLAS OR SIMILAR) FLOOR AND BASE FIN. AS SCHEDULE AIR BARRIER 2" X 6" WOOD STUD, 16" O.C XS4 - STONE FINISH: DOUBLE-SIDED WING COLOR F: SEE GRAPHIC LEGENDCODE MIN R-VALUE: NOT REQUIREDR-VALUE: NOT REQUIREDUL DESIGN: U349FIRE RATING: 2 HOURS FROM EXTERIOR, 1 HOUR FROM INTERIORSTC RATING: N/ASTC TEST: N/AHEIGHT: CONTINUOUS MANUFACTURED STONE VENEER MIN.0' - 6"1" RIGID XPS INSULATION FOUNDATION WEEP SCREED FOUNDATION 5/8" EXTERIOR GWB (DENSGLAS OR SIMILAR) +/- 0' - 11 1/4" MANUFACTURED STONE VENEER OVER MORTAR SCRATCH AND SETTING BEDS MANUFACTURED STONE VENEER OVER MORTAR SCRATCH AND SETTING BEDS CABINET EXTERIOR 5/8" EXTERIOR GWB (DENSGLAS OR SIMILAR) VAPOR BARRIER XS5 - 2X4 STUD WALL @ OUTDOOR KITCHEN 5/8" EXTERIOR GWB (DENSGLAS OR SIMILAR) AIR BARRIER 2" X 4" WOOD STUD, 16" O.C COLOR F: SEE GRAPHIC LEGENDCODE MIN R-VALUE: NOT REQUIREDR-VALUE: NOT REQUIREDUL DESIGN: U349FIRE RATING: 1 HOURSTC RATING: N/ASTC TEST: N/AHEIGHT: - FOUNDATION MANUFACTURED STONE VENEER OVER MORTAR SCRATCH AND SETTING BEDS 3/4" SOLID SURFACE BACKSPLASH EXTERIOREXTERIOR 5/8" EXTERIOR GWB (DENSGLAS OR SIMILAR) VAPOR BARRIER XE7 - STONE FINISH: STONE VENEER / SOLID SURFACE 1/2" CEMENT BOARD AIR BARRIER 2" X 4" WOOD STUD, 16" O.C COLOR F: SEE GRAPHIC LEGEND AND ENLARGED KITCHEN DRAWINGSCODE MIN R-VALUE: NOT REQUIREDR-VALUE: NOT REQUIREDUL DESIGN: U349FIRE RATING: 1 HOURSTC RATING: N/ASTC TEST: N/AHEIGHT: CONTINUOUS FOUNDATION VAPOR BARRIER AIR BARRIER 3/4" SOLID SURFACE BACKSPLASH MANUFACTURED STONE VENEER OVER MORTAR SCRATCH AND SETTING BEDS ROOF XE9 - STONE FINISH: PARAPET 5/8" EXTERIOR GWB (DENSGLAS OR SIMILAR) 2" X 6" WOOD STUD, 16" O.C COLOR F: SEE GRAPHIC LEGENDCODE MIN R-VALUE: NOT REQUIREDR-VALUE: NOT REQUIREDUL DESIGN: U349FIRE RATING: 1 HOURSTC RATING: N/ASTC TEST: N/AHEIGHT: CONTINUOUS EXTERIOR 5/8" EXTERIOR GWB (DENSGLAS OR SIMILAR) VAPOR BARRIER AIR BARRIERAIR BARRIER TPO ROOFING PARAPET CAP 0' - 7" 0' - 6"+/- 0' - 7 1/2" INTERIOR XE8 - STONE FINISH: SOFFIT 5/8" EXTERIOR GWB (DENSGLAS OR SIMILAR) 2" X 4" WOOD STUD, 16" O.C COLORS A-E: SEE GRAPHIC LEGENDCODE MIN R-VALUE: NOT REQUIREDR-VALUE: NOT REQUIREDUL DESIGN: U349FIRE RATING: 1 HOURSTC RATING: N/ASTC TEST: N/AHEIGHT: CONTINUOUS EXTERIOR 5/8" EXTERIOR GWB (DENSGLAS OR SIMILAR) MANUFACTURED STONE VENEER OVER MORTAR SCRATCH AND SETTING BEDS +/- 0' - 7" MANUFACTURED STONE VENEER OVER MORTAR SCRATCH AND SETTING BEDS XE-A / PT-A / PC-ABEIGE EIFS/MATCH SHERWIN-WILLIAMSPAINT / POWDER-COAT SW6154 NACRE (263-C2) XE-B / PT-B / PC-BLIGHT BROWN EIFS / MATCH SHERWIN-WILLIAMSPAINT / POWDER-COAT SW7153 SANDERLING (248-C5) GRAPHIC EXTERIOR MATERIAL LEGEND XE-C / PT-C / PC-CMID BROWN EIFS /MATCH SHERWIN-WILLIAMSPAINT / POWDER-COAT SW7525 TREE BRANCH (288-C7) XE-D / PT-D / PC-DRED BROWN EIFS / MATCH SHERWIN-WILLIAMSPAINT / POWDER-COAT SW6118 LEATHER BOUND (291-C7) XE-E / PT-E / PC-EDARK BROWN EIFS / MATCH SHERWIN-WILLIAMSPAINT / POWDER-COAT SW7510 CHATEAU BROWN (242-C7) XS-FMANUFACTURED STONE CULTURED STONE VENEER CLADDING COUNTRY LEDGESTONEASHFALL XW-G / WD-1 WOOD-LOOK KNOTWOOD, 6" CLADDINGALUMINUM CLADDING WESTERN RED CEDAR 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216EXTERIOR WALL TYPES- STONE VENEER A-514 FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 0'4" 8"1' 4" SCALE: 1 1/2" = 1'-0" NOTE:SEE MANUFACTURER'S TECHNICAL SUBMITTAL PACKAGE FOR INSTALLATION DETAILS EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV Revision Schedule Number Description Date XE-A / PT-A / PC-ABEIGE EIFS/MATCH SHERWIN-WILLIAMSPAINT / POWDER-COAT SW6154 NACRE (263-C2) XE-B / PT-B / PC-BLIGHT BROWN EIFS / MATCH SHERWIN-WILLIAMSPAINT / POWDER-COAT SW7153 SANDERLING (248-C5) GRAPHIC EXTERIOR MATERIAL LEGEND XE-C / PT-C / PC-CMID BROWN EIFS /MATCH SHERWIN-WILLIAMSPAINT / POWDER-COAT SW7525 TREE BRANCH (288-C7) XE-D / PT-D / PC-DRED BROWN EIFS / MATCH SHERWIN-WILLIAMSPAINT / POWDER-COAT SW6118 LEATHER BOUND (291-C7) XE-E / PT-E / PC-EDARK BROWN EIFS / MATCH SHERWIN-WILLIAMSPAINT / POWDER-COAT SW7510 CHATEAU BROWN (242-C7) XS-FMANUFACTURED STONE CULTURED STONE VENEER CLADDING COUNTRY LEDGESTONEASHFALL XW-G / WD-1 WOOD-LOOK KNOTWOOD, 6" CLADDINGALUMINUM CLADDING WESTERN RED CEDAR INTERIOREXTERIOR 5/8" EXTERIOR GWB (DENSGLAS OR SIMILAR) VAPOR BARRIER XW1 - ALUMINUM SIDING: NO SHEAR LAYER TYPE X 5/8" GYPSUM WALL BD. FLOOR AND BASE FIN. AS SCHEDULE AIR BARRIER 2" X 6" WOOD STUD, 16" O.C, FILLED WITH FIBERGLASS BATT INSULATION COLOR G: SEE GRAPHIC LEGENDCODE MIN R-VALUE: R:20 STD + R3.8 CIR-VALUE: R-20 STUD + R-10.6 CIUL DESIGN: U349FIRE RATING: 2 HOURS FROM EXTERIOR, 1 HOUR FROM INTERIORSTC RATING: 50 (EXTRAPOLATED)STC TEST: NGC 2015085HEIGHT: CONTINUOUS LAYER TYPE X 5/8" ACOUSTIC GYPSUM WALL BD. XD3 - THERMAL SOFFIT, UNEXPOSED TO OUTSIDE COLOR: INTERIOR FINISHES AS NOTEDCODE MIN R-VALUE: R:20 STD + R3.8 CIR-VALUE: R-20 STUD + R-5.3 CIUL DESIGN: U349FIRE RATING: 2 HOURS FROM EXTERIOR, 1 HOUR FROM INTERIORSTC RATING: 50 (EXTRAPOLATED)STC TEST: NGC 2015085HEIGHT: CONTINUOUS 2" RIGID XPS INSULATION XD1 - COURTYARD CLOSET WALL COLOR: INTERIOR FINISHES AS NOTEDCODE MIN R-VALUE: R:20 STD + R3.8 CIR-VALUE: R-20 STUD + R-5.3 CIUL DESIGN: U349FIRE RATING: 2 HOURS FROM EXTERIOR, 1 HOUR FROM INTERIORSTC RATING: 50 (EXTRAPOLATED)STC TEST: NGC 2015085HEIGHT: CONTINUOUS 6" WOOD-LOOK ALUMINUM CLADDING SLATS XD4 - ELEVATOR SHAFT AT ROOF COLOR: NO ADDITIONAL FINISHES NEEDEDCODE MIN R-VALUE: R:20 STD + R3.8 CIR-VALUE: R-20 STUD + R-5.3 CIUL DESIGN: U349FIRE RATING: 2 HOURS FROM EXTERIOR, 1 HOUR FROM INTERIORSTC RATING: 50 (EXTRAPOLATED)STC TEST: NGC 2015085HEIGHT: CONTINUOUS ROOF XWP - ALUMINUM SIDING: PARAPET 5/8" EXTERIOR GWB (DENSGLAS OR SIMILAR) 2" X 6" WOOD STUD, 16" O.C COLOR G: SEE GRAPHIC LEGENDCODE MIN R-VALUE: R:20 STD + R3.8 CIR-VALUE: R-20 STUD + R-10.6 CIUL DESIGN: U349FIRE RATING: 2 HOURS FROM EXTERIOR, 1 HOUR FROM INTERIORSTC RATING: 50 (EXTRAPOLATED)STC TEST: NGC 2015085HEIGHT: CONTINUOUS EXTERIOR 5/8" EXTERIOR GWB (DENSGLAS OR SIMILAR) VAPOR BARRIER AIR BARRIERAIR BARRIER TPO ROOFING PARAPET CAP XD5 - VESTIBULE SOFFIT, UNEXPOSED TO OUTSIDE COLOR: NO ADDITIONAL FINISHES NEEDEDUL DESIGN: U305FIRE RATING: N/ASTC RATING: N/ASTC TEST: N/AHEIGHT: TO CEILING 0' - 10" 2" RIGID XPS INSULATION 6" WOOD-LOOK ALUMINUM CLADDING SLATS INTERIOR XW2 - ALUMINUM SIDING: SOFFIT 5/8" EXTERIOR GWB (DENSGLAS OR SIMILAR) 2" X 4" WOOD STUD, 16" O.C COLOR G: SEE GRAPHIC LEGENDCODE MIN R-VALUE: NOT REQUIREDR-VALUE: NOT REQUIREDUL DESIGN: U349FIRE RATING: 1 HOURSTC RATING: N/ASTC TEST: N/AHEIGHT: CONTINUOUS EXTERIOR 5/8" EXTERIOR GWB (DENSGLAS OR SIMILAR) 6" WOOD-LOOK ALUMINUM CLADDING SLATS 0' - 5 1/4"0' - 9 1/4" FOUNDATION INTERIOR EXTERIOR 5/8" EXTERIOR GWB (DENSGLAS OR SIMILAR) VAPOR BARRIER LAYER TYPE X 5/8" GYPSUM WALL BD. FLOOR AND BASE FIN. AS SCHEDULE AIR BARRIER 2" X 6" WOOD STUD, 16" O.C, FILLED WITH FIBERGLASS BATT INSULATION LAYER TYPE X 5/8" ACOUSTIC GYPSUM WALL BD. 1" RIGID XPS INSULATION 0' - 9" BALCONY 2" X 4" WOOD STUD, 16" O.C XD2 - BALCONY DEMISING WALL 1/2" FIBER CEMENT PANEL COLOR: FINISHES AS NOTEDUL DESIGN: U305FIRE RATING: N/ASTC RATING: N/ASTC TEST: N/AHEIGHT: TO CEILING BALCONY ISOLATE WALL FROM BALCONY CEILING AND FLOOR ISOLATE WALL FROM BALCONY CEILING AND FLOOR BALCONY INTERIOREXTERIOR LAYER TYPE X 5/8" GYPSUM WALL BD. VAPOR BARRIER 2 LAYERS TYPE X 5/8" GYPSUM WALL BD. AIR BARRIER 2" X 6" WOOD STUD, 16" O.C, FILLED WITH FIBERGLASS BATT INSULATION1" RIGID XPS INSULATION 0' - 9" ELEVATOREXTERIOR 5/8" EXTERIOR GWB (DENSGLAS OR SIMILAR) VAPOR BARRIER AIR BARRIER 1" RIGID XPS INSULATION 2 LAYERS TYPE X 1" GYPSUM WALL BD. SHAFT LINER 2" X 6" WOOD STUD, 16" O.C, FILLED WITH FIBERGLASS BATT INSULATION H CHANNEL, 24" O.C. 3/4" AIR SPACE 1/4" COVER BOARD TPO ROOFING 5/8" EXTERIOR GWB (DENSGLAS OR SIMILAR) 2" X 6" WOOD STUD, 16" O.C VESTIBULEROOF 5/8" EXTERIOR GWB (DENSGLAS OR SIMILAR) TPO ROOFING VAPOR BARRIER VAPOR BARRIER AIR BARRIER 0' - 6 3/4"0' - 10" XD6 - ELEVATOR PIT WALL COLOR: NO ADDITIONAL FINISHES NEEDEDCODE MIN R-VALUE: R-10 CIR-VALUE: R-10.6 CIUL DESIGN: U349FIRE RATING: 3 HOURSSTC RATING: 57STC TEST: HUD LISTINGHEIGHT: SUB-GRADE 8" CAST-IN-PLACE CONCRETE WALL VAPOR BARRIER 2" RIGID XPS INSULATION ROOM 3-5/8" METAL STUD, 16" O.C P9.1 METAL STUD, GWB SOFFIT 5/8" TYPE X GWB P9.1- GWB ON METAL STUDUL DESIGN: N/AFIRE RATING: N/ASTC RATING: N/ASTC TEST: N/AHEIGHT: -0' - 4 1/4"CABINETRY 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216EXTERIOR WALL TYPES A-515 FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 0'4" 8"1' 4" SCALE: 1 1/2" = 1'-0" NOTE:SEE MANUFACTURER'S TECHNICAL SUBMITTAL PACKAGE FOR INSTALLATION DETAILS EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV Revision Schedule Number Description Date 2" X 6" WOOD STUD, 16" O.C P22X6 STUD, GENERAL PARTITION 5/8" TYPE X GWB FLOOR AND BASE FIN. AS SCHEDULED (P2.1) 5 1/2" BATT INSULATION (P2.2) NO INSULATION INTERIORINTERIOR 2" X 4" WOOD STUD, 16" O.C P12X4 STUD, GENERAL PARTITION 5/8" TYPE X GWB (P1.1) 3 1/2" BATT INSULATION (P1.2) NO INSULATION P1.1- INSULATEDUL DESIGN: U305FIRE RATING: N/ASTC RATING: 36STC TEST: NGC 2008029HEIGHT: TO CEILING P1.2- UNINSULATEDUL DESIGN: U305FIRE RATING: N/ASTC RATING: 35STC TEST: NGC 2403HEIGHT: TO CEILING INTERIORINTERIOR P2.1- INSULATEDUL DESIGN: U305FIRE RATING: 1 HOURSTC RATING: 38STC TEST: NGC 2008032HEIGHT: TO DECK ABOVE P2.2- UNINSULATEDUL DESIGN: U305FIRE RATING: 1 HOURSTC RATING: 35STC TEST: NGC 2403HEIGHT: TO DECK ABOVE 0' - 4 3/4"0' - 6 3/4" 2" X 6" WOOD STUD, 16" O.C P22X6 STUD, GENERAL PARTITION 5/8" TYPE X GWB INTERIORINTERIOR P2.3- DOUBLE SHEARUL DESIGN: U305FIRE RATING: 1 HOURSTC RATING: 35STC TEST: NGC 2403HEIGHT: TO DECK ABOVE 1/2" OR 5/8" PLYWOOD SHEATHING, SEE STRUCTURAL 0' - 7 3/4" TO 0' - 8" 2" X 6" WOOD STUD, 16" O.C P3 2X6 STUD, ACOUSTIC DEMISING 5/8" TYPE X ACOUSTIC GWB NOISIER SIDE QUIETER SIDE P3.3- DOUBLE SHEARUL DESIGN: U305FIRE RATING: 1 HOURSTC RATING: 57STC TEST: NGC 2010081HEIGHT: TO DECK ABOVE 1/2" OR 5/8" PLYWOOD SHEATHING, SEE STRUCTURAL 0' - 8 15/16" TO 0' - 9 3/16" 5/8" TYPE X GWB FLOOR AND BASE FIN. AS SCHEDULEDFLOOR AND BASE FIN. AS SCHEDULED SOUND ISOLATION CLIPS 2" X 6" WOOD STUD, 16" O.C P3 2X6 STUD, ACOUSTIC DEMISING 5/8" TYPE X ACOUSTIC GWB NON-SHEAR SIDE SHEAR SIDE P3.2- SINGLE SHEARUL DESIGN: U305FIRE RATING: 1 HOURSTC RATING: 57STC TEST: NGC 2010081HEIGHT: TO DECK ABOVE 0' - 7 3/4" TO 0' - 7 7/8" 5/8" TYPE X GWB RC-1 RESILIENT CHANNELS 5 1/2" BATT INSULATION 1/2" OR 5/8" PLYWOOD SHEATHING, SEE STRUCTURAL 5 1/2" BATT INSULATION 2" X 6" WOOD STUD, 16" O.C P3 2X6 STUD, ACOUSTIC DEMISING 5/8" TYPE X ACOUSTIC GWB P3.1- NON-SHEARUL DESIGN: U305FIRE RATING: 1 HOURSTC RATING: 57STC TEST: NGC 2010081HEIGHT: TO DECK ABOVE 0' - 7 1/4" 5/8" TYPE X GWB RC-1 RESILIENT CHANNELS (P3.1) 5 1/2" BATT INSULATION NOISIER SIDE QUIETER SIDE FLOOR AND BASE FIN. AS SCHEDULED FLOOR AND BASE FIN. AS SCHEDULEDFLOOR AND BASE FIN. AS SCHEDULED 2" X 6" WOOD STUD, 16" O.C P42X6 STUD, 2 HR ACOUSTIC DEMISING NON-SHEAR SIDESHEAR SIDE/STAIR P4.2- SINGLE SHEARUL DESIGN: U301FIRE RATING: 2 HOURSSTC RATING: 61STC TEST: NGC 2011068HEIGHT: TO DECK ABOVE 0' - 9" TO 0' - 9 1/8" RC-1 RESILIENT CHANNELS 1/2" OR 5/8" PLYWOOD SHEATHING, SEE STRUCTURAL 5 1/2" BATT INSULATION 2" X 6" WOOD STUD, 16" O.C P42X6 STUD, 2 HR ACOUSTIC DEMISING 5/8" TYPE X ACOUSTIC GWB P4.1- NON-SHEARUL DESIGN: U301FIRE RATING: 2 HOURSSTC RATING: 61STC TEST: NGC 2011068HEIGHT: TO DECK ABOVE 0' - 8 3/8" 2 LAYERS 5/8" TYPE X GWB RC-1 RESILIENT CHANNELS 5 1/2" BATT INSULATION NOISIER SIDE/STAIRQUIETER SIDE FLOOR AND BASE FIN. AS SCHEDULEDFLOOR AND BASE FIN. AS SCHEDULED 1/2" TYPE X GWB 5/8" TYPE X ACOUSTIC GWB 5/8" TYPE X GWB 2 LAYERS 5/8" TYPE X GWB2" X 6" WOOD STUD, 16" O.C. P42X6 STUD, 2 HR ACOUSTIC DEMISING 5/8" TYPE X ACOUSTIC GWB PUBLIC SIDESTAIR P4.3- DOUBLE SHEAR UL DESIGN: U301FIRE RATING: 2 HOURSSTC RATING: 48 (EXTRAPOLATED)STC TEST: NGC 2009010 (EXTRAPOLATED)HEIGHT: TO DECK ABOVE 1/2" OR 5/8" PLYWOOD SHEATHING, SEE STRUCTURAL 0' - 9" TO 0' - 9 1/4" 5/8" TYPE X GWB FLOOR AND BASE FIN. AS SCHEDULED 5/8" TYPE X GWB 5/8" TYPE X ACOUSTIC GWB 5 1/2" BATT INSULATION P3.4- UNINSULATEDUL DESIGN: U305FIRE RATING: 1 HOURSTC RATING: N/ASTC TEST: N/AHEIGHT: TO DECK ABOVE (P3.4) NO INSULATION P52X6 STUD, ELEVATOR SHAFT P5.1- NO SHEARUL DESIGN: U349FIRE RATING: 2 HOURSSTC RATING: 58STC TEST: NGC 2011069HEIGHT: TO DECK ABOVE P5 2X6 STUD, ELEVATOR SHAFT P5.2- SINGLE SHEAR UL DESIGN: U349FIRE RATING: 2 HOURSSTC RATING: 58STC TEST: NGC 2011069HEIGHT: TO DECK ABOVE 2" X 6" WOOD STUD, 16" O.C.5/8" TYPE X GWB 5 1/2" BATT INSULATION PUBLIC/BOH FLOOR AND BASE FIN. AS SCHEDULED 1" TYPE X GWB SHAFT LINER ELEVATOR 0' - 9" H CHANNEL, 24" O.C. 3/4" AIR SPACE 2" X 6" WOOD STUD, 16" O.C. 1/2" OR 5/8" PLYWOOD SHEATHING, SEE STRUCTURAL 5 1/2" BATT INSULATION PUBLIC/BOH FLOOR AND BASE FIN. AS SCHEDULED 1" TYPE X GWB SHAFT LINER ELEVATOR 0' - 9 3/8" TO 0' - 9 1/2" H CHANNEL, 24" O.C. 3/4" AIR SPACE 5/8" TYPE X GWB P5 2X6 STUD, SHAFT TO SHAFT P5.3- NO SHEAR, SHAFT-TO-SHAFT UL DESIGN: U305FIRE RATING: 2 HOURSSTC RATING: 35STC TEST: NGC 2403HEIGHT: TO DECK ABOVE 2" X 6" WOOD STUD, 16" O.C. LINEN CHUTE 1" TYPE X GWB SHAFT LINER ELEVATOR H CHANNEL, 24" O.C. 3/4" AIR SPACE 1" TYPE X GWB SHAFT LINER 0' - 9 1/4" INTERMEDIATE FLOOR INTERMEDIATE FLOOR •• SPECIALTY GYPSUM BOARD NOTESUSE MOISTURE RESISTANT GWB IN RESTROOMS, POOL ROOM, LAUNDRY ROOMS, MEP ROOMS, FOOD PREP SPACES AND SPACES WITH KITCHENS WHERE ACOUSTIC OR HIGH IMPACT GWB IS NOT SPECIFIED.USE HIGH-IMPACT GWB IN BOH LAUNDRY AND LINEN ROOMSPARTITION LEGEND 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216PARTITION TYPES A-516 FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 0'4" 8"1' 4" SCALE: 1 1/2" = 1'-0" EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV Revision Schedule Number Description Date 2" X 4" WOOD STUD, 16" O.C 5/8" MOISTURE RESISTANT TYPE X GYPSUM WALL BD. FLOOR AND BASE FIN. AS SCHEDULE 3 1/2" BATT INSULATION PLUMBING SPACE / GAP •• SPECIALTY GYPSUM BOARD NOTESUSE MOISTURE RESISTANT GWB IN RESTROOMS, POOL ROOM, LAUNDRY ROOMS, MEP ROOMS, FOOD PREP SPACES AND SPACES WITH KITCHENS WHERE ACOUSTIC OR HIGH IMPACT GWB IS NOT SPECIFIED.USE HIGH-IMPACT GWB IN BOH LAUNDRY AND LINEN ROOMS 2" X 6" WOOD STUD, 16" O.C. P52X6 STUD, GUESTROOM WALL SHAFT SHAFT P5.6- GUESTROOM WALL WITH ADDITIONAL LINER LAYERUL DESIGN: U305 + 1" SHAFT LINERFIRE RATING: 2 HOURSSTC RATING: 57STC TEST: NGC 2010081HEIGHT: TO DECK ABOVE 1" TYPE X GWB SHAFT LINER IN BATHROOM SHAFT. IF SHAFT ON BOTH SIDES, ADD LINER ONLY ON ONE SIDE. FLOOR AND BASE FIN. AS SCHEDULED INTERIOR INTERIOR 2" X 4" WOOD STUD, 16" O.C P62X4 STUD, 2 HR GENERAL PARTITION 2 LAYERS 5/8" TYPE X GWB EACH SIDE P6- UNINSULATEDUL DESIGN: U301FIRE RATING: 2 HOURSSTC RATING: 40STC TEST: NGC 2363HEIGHT: TO DECK ABOVE 0' - 6" FLOOR AND BASE FIN. AS SCHEDULED P52X6 STUD, SHAFT DEMISING P5.4- NO SHEAR, SHAFT-TO-SHAFTUL DESIGN: U305FIRE RATING: 1 HOURSTC RATING: N/ASTC TEST: N/AHEIGHT: TO DECK ABOVE 2" X 6" WOOD STUD, 16" O.C. ELEVATOR 1" TYPE X GWB SHAFT LINER ELEVATOR 1" TYPE X GWB SHAFT LINER 0' - 7 1/2" P52X6 STUD, PLUMBING SHAFT P5.5- METAL STUD, NO SHUL DESIGN: U415-BFIRE RATING: 2 HOURSSTC RATING: N/ASTC TEST: N/AHEIGHT: TO DECK ABOVE 2" X 6" WOOD STUD, 16" O.C. ROOM 1" TYPE X GWB SHAFT LINER SHAFT 5/8" TYPE X GWB SHAFT LINER 0' - 4 3/4" INTERMEDIATE FLOOR GUEST ROOM ORSHAFT VARIES P3.1P3.2 P3.3 P7 (2) 2X4 STUD, PLUMBING WALL P7- PLUMBING WALLUL DESIGN: U341FIRE RATING: 1 HOURSTC RATING: 54STC TEST: NGC 2198HEIGHT: TO DECK ABOVE ROOM 2" X 4" WOOD STUD, 16" O.C P8 2X4 STUD, FURRED OUT 5/8" TYPE X GWB P8- UNINSULATED STUDUL DESIGN: N/AFIRE RATING: N/ASTC RATING: N/ASTC TEST: N/AHEIGHT: TO CEILING FLOOR AND BASE FIN. AS SCHEDULED ROOM 3-5/8" METAL STUD, 16" O.C P9METAL STUD, GWB SOFFIT 5/8" TYPE X GWB P9.1- GWB ON METAL STUDUL DESIGN: N/AFIRE RATING: N/ASTC RATING: N/ASTC TEST: N/AHEIGHT: TO CEILING FLOOR AND BASE FIN. AS SCHEDULED 0' - 4 1/4" 1' - 0"0' - 4 1/4" ROOM 3-5/8" METAL STUD, 16" O.C P9METAL STUD, PLASTIC LAM. SOFFIT 5/8" TYPE X GWB P9.2- PLASTIC LAMINATE PLANKS ON METAL STUDUL DESIGN: N/AFIRE RATING: N/ASTC RATING: N/ASTC TEST: N/AHEIGHT: TO CEILING FLOOR AND BASE FIN. AS SCHEDULED 0' - 5 1/4" 8" WIDE LAMINATE PLANK ON Z-CLIPS ROOF ACCESSSTAIR 2" X 4" WOOD STUD, 16" O.C P102X4 STUD, ROOF ACCESS WALL 5/8" TYPE X GWB 3 1/2" BATT INSULATION P10- UNINSULATED BETWEEN ACCESS AND STAIRUL DESIGN: U305FIRE RATING: N/ASTC RATING: 35STC TEST: NGC 2403HEIGHT: - 0' - 4 3/4" 5/8" PLYWOOD OR OSB CT-#TILE FINISH - SHOWER WALL COLOR - AS NOTEDSHOWER WALL TILE INSTALLATIONINSTALL BACKING FOR ALL FIXTURES,GRAB BARS, ETC PER LEGENDSHEIGHT: TO CEILING OPPOSITE INTERIOR STUD WALL 1/2" CEMENT BACKER BOARD VAPOR RETARDER LIQUID APPLIED WATERPROOFING MEMBRANE TILE OR SHOWER SURROUND PANEL AS SCHEDULED OVER CEMENTITIOUS BOND COAT PREMANUFACTURED SHOWER BASE CT-#TILE FINISH - AT TILE FLOOR COLOR - AS NOTEDWALL TILE INSTALLATIONUL DESIGN: N/AFIRE RATING: N/ASTC RATING: N/ASTC TEST: N/AHEIGHT: TO CEILING OPPOSITE INTERIOR STUD WALL 1/2" CEMENT BACKER BOARD VAPOR RETARDER LIQUID APPLIED WATERPROOFING MEMBRANE TILE AS SCHEDULED OVER CEMENTITIOUS BOND COAT PARTITION LEGEND AND WALL FINISH DETAILS SS-#SOLID SURFACE BACKSPLASH COLOR - AS NOTEDSOLID SURFACE BACKSPLASH INSTALLATIONUL DESIGN: N/AFIRE RATING: N/ASTC RATING: N/ASTC TEST: N/AHEIGHT: AS NOTED IN INTERIOR ELEVATIONS OPPOSITE INTERIOR STUD WALL 1/2" CEMENT BACKER BOARD THINSET SOLID SURFACE BACKSPLASH SOLID SURFACE COUNTER OVER 3/4" PLYWOOD 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216PARTITION TYPES A-517 FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 0'4" 8"1' 4" SCALE: 1 1/2" = 1'-0" EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV Revision Schedule Number Description Date SUSPENEDED GWB CEILINGSEE RCPS FOR GWB TYPE. SEE FLOOR-CEILING ASSEMBLY TYPES AND STRUCTURAL DRAWINGS TO DETERMINE FLOOR ASSEMBLY NOTE: ALL CONSTRUCTION IN CONCEALED SPACE TO BE NON- COMBUSTIBLE SUSPENEDED GWB CEILINGSEE RCPS FOR GWB TYPE. SEE FLOOR-CEILING ASSEMBLY TYPES AND STRUCTURAL DRAWINGS TO DETERMINE FLOOR ASSEMBLY SUSPENEDED ACOUSTIC CEILINGSEE RCPS AND SCHEDULE FOR ACT TYPE. SEE MANUFACTURER'S DETAILS FOR ASSEMBLY OF EACH TYPE OF SYSTEM. SEE FLOOR-CEILING ASSEMBLY TYPES AND STRUCTURAL DRAWINGS TO DETERMINE FLOOR ASSEMBLY NOTE: ALL CONSTRUCTION IN CONCEALED SPACE TO BE NON- COMBUSTIBLE CL-A2X2 SUSPENDED ACOUSTIC CEILING LOCATION: THROUGHOUT BUILDING AS NOTED CL-A WHITE, FINE TEXTURE, CONCEALED SUSPENSION SYSTEM CL-A1 GREY, FINE TEXTURE, CONCEALED SUSPENSION SYSTEM CL-A2 WHITE, WASHABLE, CLEAN ROOM SUSPENSION SYSTEM CL-BSUSPENDED GYPSUM BOARD CEILING (1 HOUR) LOCATION: THROUGHOUT BUILDING AS NOTED CL-B SUSPENDED SYSTEM, 1 LAYER TYPE X GWB, PT-01 FINISH CL-B2 SUSPENDED SYSTEM, 1 LAYER MOISTURE-RESISTANT GWB, PT-01 FINISH CL-B DIRECT-ATTACHED GYPSUM BOARD CEILING (1 HOUR) LOCATION: BACK-OF-HOUSE SPACES AS NOTED CL-B1 DIRECT-ATTACHED, 1 LAYER TYPE X GWB, PT-01 FINISH CL-B3 DIRECT-ATTACHED, 1 LAYER MOISTURE-RESISTANT GWB, PT-01 FINISH CEILING TYPES SUSPENEDED GWB CEILINGSEE RCPS FOR GWB TYPE. SEE FLOOR-CEILING ASSEMBLY TYPES AND STRUCTURAL DRAWINGS TO DETERMINE FLOOR ASSEMBLY NOTE: ALL CONSTRUCTION IN CONCEALED SPACE TO BE NON- COMBUSTIBLE SUSPENEDED GWB CEILINGSEE RCPS FOR GWB TYPE. SEE FLOOR-CEILING ASSEMBLY TYPES AND STRUCTURAL DRAWINGS TO DETERMINE FLOOR ASSEMBLY CL-DSUSPENDED FIBER CEMENT EXTERIOR SOFFIT LOCATION: EXTERIOR UNDER CANOPIES, BALCONIES, AT ENTRY CL-D SUSPENDED SYSTEM, 1 LAYER 1/2" FIBER CEMENT, PT-01FINISH CL-D DIRECT-ATTACHED FIBER CEMENT EXTERIOR SOFFIT LOCATION: BACK-OF-HOUSE SPACES AS NOTED CL-B1 DIRECT-ATTACHED, 1 LAYER TYPE X GWB, PT-01 FINISH CL-B3 DIRECT-ATTACHED, 1 LAYER MOISTURE-RESISTANT GWB, PT-01 FINISH SUSPENEDED GWB CEILINGSEE RCPS FOR GWB TYPE. SEE FLOOR-CEILING ASSEMBLY TYPES AND STRUCTURAL DRAWINGS TO DETERMINE FLOOR ASSEMBLY NOTE: ALL CONSTRUCTION IN CONCEALED SPACE TO BE NON- COMBUSTIBLE CL-CSUSPENDED GYPSUM BOARD CEILING (2 HOURS) LOCATION: AT CEILINGS OF 2 HOUR RATED ROOMSUL DESIGN: L541FIRE RATING: 2 HOURSSTC/IIC RATINGS: SAME AS F1/F2 ASSEMBLIES MIN. 2' - 0" BTW JOINTS ADD SECOND LAYER OF 5/8" TYPE X GWB TO FLOOR-CEILING ASSEMBLY CL-ESUSPENDED PLASTIC LAMINATE CEILING LOCATION: AT LOBBY ENTRANCE CL-E SUSPENDED SYSTEM, PLASTIC LAMINATE SUSPENEDED PLASTIC LAMINATE CEILING. SEE RCPS FOR FINISH TYPE. SEE MANUFACTURER'S DETAILS FOR ASSEMBLY OF EACH TYPE OF SYSTEM. SEE FLOOR-CEILING ASSEMBLY TYPES AND STRUCTURAL DRAWINGS TO DETERMINE FLOOR ASSEMBLY NOTE: ALL CONSTRUCTION IN CONCEALED SPACE TO BE NON-COMBUSTIBLE F111-7/8"X3/4" WEB JOIST BASE FLOOR-CEILING ASSEMBLY •••• LOCATION: AT GUESTROOMSUL DESIGN: L570FIRE RATING: 1 HOURSTC RATING: 64IIC RATING: 54 (WITHOUT SUSPENDED CEILING)SOUND TEST: RAL-0T03NOTES:MINIMUM IIC BASED ON CERAMIC TILE FINISHMINIMUM STC BASED ON RESILIENT TILE FINISH DECREASED GWB BY 3/8" FROM TESTINCREASED GYP-CRETE BY 1/4" FROM TEST F2.2 2"X8" JOIST FLOOR-CEILING ASSEMBLY •• LOCATION: AT 3RD-5TH FLOOR CORRIDORSUL DESIGN: L516FIRE RATING: 1 HOURSTC RATING: 59IIC RATING: 62 (EXTRAPOLATED)SOUND TESTS: USG 74074 (STC)/USG 74075 (IIC)NOTES:DECREASED JOIST DEPTH BY 2" FROM TESTSINCREASED GYP-CRETE BY 1/2" FROM STC TEST SEE STRUCT. FOR SPACING MIN. 24" O.C. SEE STRUT. FOR SPACING MIN. 16" O.C. F2.12"X8" JOIST WITH SOUND MAT FLOOR-CEILING ASSEMBLY •• LOCATION: AT 2ND FLOOR CORRIDORUL DESIGN: L516FIRE RATING: 1 HOURSTC RATING: 59IIC RATING: 77SOUND TEST: RAL-IN04-005/TL04-032NOTES: DECREASED JOIST DEPTH BY 2" FROM TESTINCREASED GYP-CRETE BY 1/4" FROM TEST SEE STRUT. FOR SPACING MIN. 16" O.C. FLOOR-CEILING ASSEMBLY TYPES 1 1/4" GYP-CRETE 1/4" ACOUSTIC UNDERLAYMENT 5/8" TYPE X GWB RC-1 RESILIENT CHANNELS PLYWOOD WEB JOIST, SEE STRUCT. FOR SIZE AND SPECS 3.5" FIBERGLASS BATT INSULATION ATTACHED TO BOTTOM OF PLYWOOD SUBFLOOR 3/4" T&G PLYWOOD SUBFLOOR 1 1/4" GYP-CRETE 5/8" TYPE X GWB RC-1 RESILIENT CHANNELS NOMINAL LUMBER JOIST, SEE STRUCT. TO VERIFY SIZE AND SPECS 3.5" FIBERGLASS BATT INSULATION ATTACHED TO BOTTOM OF PLYWOOD SUBFLOOR 3/4" T&G PLYWOOD SUBFLOOR MAX. 18" CONCEALED SPACE0' - 11"1 1/4" GYP-CRETE 1/4" ACOUSTIC UNDERLAYMENT 5/8" TYPE X GWB RC-1 RESILIENT CHANNELS NOMINAL LUMBER JOIST, SEE STRUCT. TO VERIFY SIZE AND SPECS 3.5" FIBERGLASS BATT INSULATION ATTACHED TO BOTTOM OF PLYWOOD SUBFLOOR 3/4" T&G PLYWOOD SUBFLOOR MAX. 18" CONCEALED SPACE0' - 11"MAX. 18" CONCEALED SPACE1' - 3 1/4"NOTE: WHEN ATTACHING GWB TO RC-1, DO NOT SHORT-CIRCUIT ACOUSTIC PATH BY SCREWING THROUGH RC-1 INTO WOOD JOIST NOTE: WHEN ATTACHING GWB TO RC-1, DO NOT SHORT-CIRCUIT ACOUSTIC PATH BY SCREWING THROUGH RC-1 INTO WOOD JOIST NOTE: WHEN ATTACHING GWB TO RC-1, DO NOT SHORT-CIRCUIT ACOUSTIC PATH BY SCREWING THROUGH RC-1 INTO WOOD JOIST 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216CEILING TYPES A-518 FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 0'4" 8"1' 4" SCALE: 1 1/2" = 1'-0" EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV REVISION SCHEDULE # DESCRIPTION DATE 2 ADDENDUM 2 6/21/2024 HANGER WIRES BY OTHERS CONTROL JOINT DRYWALL SUSPENSION MAIN TEE DRYWALL SUSPENSION CROSS TEE 5/8" TYPE X GWB APPLY AT JOINT, JOINT COMPOUND AND PAPER JOINT TAPE UTAC UNOPPOSED TEE ATTACHMENT CLIPAT CONTROL JOINT, SECURE MAIN TEE TO CROSS TEE WITH UNOPPOSED TEE ATTACHMENT CLIP HANGER WIRE BY OTHERS CONTROL JOINT APPLY AT JOINT, JOINT COMPOUND AND PAPER JOINT TAPE DRYWALL SUSPENSION MAIN TEE SUSPENSION CROSS TEE 5/8" TYPE X GWB HANGER WIRE BY OTHERS APPLY AT JOINT, JOINT COMPOUND AND PAPER JOINT TAPE J-BEAD APPLY ACOUSTICAL SEALANT AT PERIMETER JOINTS, TYPICAL. DRYWALL SUSPENSION MAIN TEE DRYWALL SUSPENSION CROSS TEE SCREW GYPSUM BOARD INTO ANGLE MOLDING 5/8" TYPE X GWB MOLDING ANGLE, SECURE TO WALL WITH APROPRIATE FASTENER, TYPICAL. APPLY AT JOINT, JOINT COMPOUND AND PAPER JOINT TAPE J-BEAD APPLY ACOUSTICAL SEALANT AT PERIMETER JOINTS, TYPICAL. MOLDING ANGLE, SECURE TO WALL WITH APROPRIATE FASTENER, TYPICAL. DRYWALL SUSPENSION CROSS TEE DRYWALL SUSPENSION MAIN TEE HANGER WIRE BY OTHERS SCREW GYPSUM BOARD TO ANGLE MOLDING 5/8" TYPE X GWB APPLY AT JOINT, JOINT COMPOUND AND PAPER JOINT TAPE DRYWALL SUSPENSION MAIN TEE J-BEAD APPLY ACOUSTICAL SEALANT AT PERIMETER JOINTS, TYPICAL. 0' - 0 3/8" DRYWALL SUSPENSION CROSS TEE 5/8" TYPE X GWB SCREW GYPSUM BOARD INTO ANGLE MOLDING HANGER WIRE BY OTHERSMOLDING ANGLE, SECURE TO WALL WITH APROPRIATE FASTENER, TYPICAL. MOLDING ANGLE, SECURE TO WALL WITH APROPRIATE FASTENER, TYPICAL.DRYWALL SUSPENSION CROSS TEE DRYWALL SUSPENSION MAIN TEE HANGER WIRE BY OTHERS 5/8" TYPE X GWBAPPLY AT JOINT, JOINT COMPOUND AND PAPER JOINT TAPE J-BEAD APPLY ACOUSTICAL SEALANT AT PERIMETER JOINTS, TYPICAL. SCREW GYPSUM BOARD INTO ANGLE MOLDING 0' - 0 3/8" HANGER WIRE BY OTHERS APPLY AT JOINT, JOINT COMPOUND AND PAPER JOINT TAPE DRYWALL SUSPENSION MAIN TEE DRYWALL SUSPENSION CROSS TEE 5/8" TYPE X GWB 8" MAX.6" MAX.DRYWALL SUSPENSION CROSS TEE J-BEAD MITERED DRYWALL SUSPENSION MAIN TEE CHANNEL MOLDING CORNER BEAD DRYWALL SUSPENSIONCROSS TEE HANGER WIRE BY OTHERS APPLY AT JOINT, JOINT COMPOUND AND PAPER JOINT TAPE ANGLE MOLDING0' - 4"APPLY AT JOINT, JOINT COMPOUND AND PAPER JOINT TAPE 5/8" TYPE X GWB 5/8" TYPE X GWB DRYWALL SUSPENSION CROSS TEE APPLY AT JOINT, JOINT COMPOUND AND PAPER JOINT TAPE TRANSITION CLIP OR METAL STUD DRYWALL SUSPENSION MAIN TEE ANGLE MOLDING HANGER WIRE BY OTHERS DRYWALL SUSPENSIONMAIN TEE CORNER BEAD NOTE: VERTICAL HEIGHTS OVER 6" REQUIRE DIAGONAL BRACINGJ-BEAD CHANNEL MOLDING 5/8" TYPE X GWB 5/8" TYPE X GWB APPLY AT JOINT, JOINT COMPOUND AND PAPER JOINT TAPE APPLY AT JOINT, JOINT COMPOUND AND PAPER JOINT TAPE ANGLE MOLDING COMPASSO ELITE TRIM OR EQ. HEIGHT PER DRAWINGS ATTACH BRACING TO TOP EDGE OF TRIM BRACING, ATTACH EVERY 4'-0" FROM GRID BULB TO TOP OF TRIM. FASTEN WITH SELF-DRILLING SCREWS FASTEN TO BULB OF GRID DRYWALL SUSPENSION MAIN TEE HANGER WIRE BY OTHERS DRYWALL SUSPENSION CROSS TEE FLOAT 2" - 6" BEYOND GRID ATTACH FRAMING ANGLE AROUND ENTIRE PERIMETER 1/4" BACK FROM EDGE, SCREWS SPACED 16" O.C. COMPASSO ELITE SPLICE CLIP OR EQ. 5/8" TYPE X GWB HANGER WIRE BY OTHERS APPLY AT JOINT, JOINT COMPOUND AND PAPER JOINT TAPE DRYWALL SUSPENSION MAIN TEE USG DRYWALL SUSPENSION CROSS TEE DGLW424 1/2" ALUMINUM REVEAL 5/8" TYPE X GWB HANGER WIRES BY OTHERS 0' - 4" DRYWALL SUSPENSION MAIN TEE DRYWALL SUSPENSION CROSS TEE APPLY AT JOINT, JOINT COMPOUND AND PAPER JOINT TAPE PAPER FACED METAL "J" SHAPED TAPE-ON TRIM OR "L" SHAPED TAPE ON TRIM5/8" TYPE X GWB M20 ANGLE MOLDING UTAC UNOPPOSED TEE ATTACHMENT CLIP HANGER WIRE BY OTHERS DRYWALL SUSPENSION MAIN TEE DRYWALL SUSPENSION CROSS TEE 5/8" TYPE X GWB 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216CEILING- SUSPENDEDGWB TYP. DETAILS A-520 FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 0'2" 4"8" SCALE: 3" = 1'-0" EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV 3" = 1'-0"1SUS. GWB CLNG.- CONTROL JOINT PARALLEL TO MAIN TEE 3" = 1'-0"2SUS. GWB CLNG.- CONTROL JOINT PERP. TO MAIN TEE 3" = 1'-0"6 SUS. GWB CLNG.- PANEL JOINT 3" = 1'-0"4SUS. GWB CLNG.- PERIMETER AT MAIN TEE 3" = 1'-0"5SUS. GWB CLNG.- PERIMETER AT CROSS TEE 3" = 1'-0"12 SUS. GWB CLNG.- PERIMETER TRIM AT MAIN TEE 3" = 1'-0"7SUS. GWB CLNG.- MAIN TEE AT PERIMETER WALL 3" = 1'-0"8SUS. GWB CLNG.- CROSS TEE AT PERIMETER WALL 3" = 1'-0"10SUS. GWB CLNG.- MAIN TEE AT PERIMETER WALL W/ RELEIF 3" = 1'-0"11SUS. GWB CLNG.- CROSS TEE AT PERIMETER WALL W/ RELEIF 3" = 1'-0"9 SUS. GWB CLNG.- TYPICAL REVEAL JOINT 3" = 1'-0"13SUS. GWB CLNG.- LOW PROFILE EDGE 3" = 1'-0"3 SUS. GWB CLNG.- TYPICAL SUSPENDED GWB DETAIL REVISION SCHEDULE # DESCRIPTION DATE 2 ADDENDUM 2 6/21/2024 HANGER WIRE BY OTHERS HANGER WIRE BY OTHERS APPLY AT JOINT, JOINT COMPOUND AND PAPER JOINT TAPE ACOUSTIC TILE SYSTEM MAIN TEE USG CPALAC1 COMPASSO ELITE CLIP OREQ. COMPASSO ELITE TRANSITIONS DAS 4"TRIM OR EQ. USG CPALAC1 COMPASSO ELITE CLIP OREQ. DRYWALL SUSPENSION MAIN TEE DRYWALL SUSPENSION CROSS TEE ACOUSTICAL CEILING PANEL 5/8" TYPE X GWB CHANNEL MOLDING DRYWALL SUSPENSION CROSS TEE HANGER WIRE BY OTHERS APPLY AT JOINT, JOINT COMPOUND AND PAPER JOINT TAPE DRYWALL SUSPENSION MAIN TEE ACOUSTICAL SUSPENSION SYSTEM CORNER BEAD ACOUSTIC PANEL J-BEAD 5/8" TYPE X GWB ANGLE MOLDING ANGLE MOLDING6" MAX.DRYWALL SUSPENSION MAIN TEE APPLY AT JOINT, JOINT COMPOUND AND PAPER JOINT TAPE DRYWALL SUSPENSION MAIN TEE, MITEREDOVERLAP & SCREW ATTACH. DO NOT CUTFACE OF TEE WHEN CREATING 90° BEND ACOUSTIC TILE SYSTEM MAIN TEE CORNER BEAD ACOUSTICAL CEILING PANEL J-BEAD 5/8" TYPE X GWB ANGLE MOLDING 6" MAX.SHADOW MOLDING CHANNEL MOLDING DRYWALL SUSPENSION CROSS TEE HANGER WIRE BY OTHERS DRYWALL SUSPENSION MAIN TEE HANGER WIRE BY OTHERS DRYWALL SUSPENSION MAIN TEE DRYWALL SUSPENSION CROSS TEE INDEPENDENTLY HUNG SPRINKLER SWING-ARM ASSEMBLY (NOT SHOWN TO SCALE) 5/8" TYPE X GWB APPLY AT JOINT, JOINT COMPOUND AND PAPER JOINT TAPE DRYWALL SUSPENSION MAIN TEE, MITEREDOVERLAP & SCREW ATTACH. DO NOT CUTFACE OF TEE WHEN CREATING 90° BEND ACOUSTIC TILE SYSTEM MAIN TEE CORNER BEAD ACOUSTICAL CEILING PANEL J-BEAD ANGLE MOLDING ANGLE MOLDING6" MAX.5/8" TYPE X GWB CHANNEL MOLDING DRYWALL SUSPENSION CROSS TEE HANGER WIRE BY OTHERS DRYWALL SUSPENSION MAIN TEE APPLY AT JOINT, JOINT COMPOUND AND PAPER JOINT TAPE CORNER BEAD 5/8" TYPE X GWB HANGER WIRE BY OTHERS PER ARCHITECT DRYWALL SUSPENSION MAIN TEE, MITEREDOVERLAP & SCREW ATTACH. DO NOT CUTFACE OF TEE WHEN CREATING 90° BEND J-BEAD CHANNEL MOLDING PER ARCHITECTDRYWALL SUSPENSION CROSS TEE 5/8" TYPE X GWB EDGE OF SOFFIT WITHOUT BACKLOAD 12" MAX. HANGAR WIRE TO ANGLE MOLDING6" MAX.UTAC UNOPPOSED TEEATTACHMENT CLIP DRYWALL SUSPENSIONCROSS TEE DRYWALL SUSPENSION MAIN TEE PER ARCHITECT NOTE: LINEAR FIXTURE SHALL NOT EXCEED 3 LBS/FT [4.5 Kg/m] DRYWALL SUSPENSIONCROSS TEE DRYWALL SUSPENSION MAIN TEE LINEAR LIGHT FIXTUREPER ARCHITECTEDGE OF SOFFIT WITH BACKLOAD 6" MAX. HANGAR WIRE TO6" MAX.UTAC UNOPPOSED TEEATTACHMENT CLIP APPLY AT JOINT, JOINT COMPOUND AND PAPER JOINT TAPE CORNER BEAD 5/8" TYPE X GWB DRYWALL SUSPENSION MAIN TEE, MITEREDOVERLAP & SCREW ATTACH. DO NOT CUTFACE OF TEE WHEN CREATING 90° BEND J-BEAD CHANNEL MOLDING DRYWALL SUSPENSION CROSS TEE 5/8" TYPE X GWB ANGLE MOLDING HANGER WIRE BY OTHERS ACOUSTIC TILE SYSTEM MAIN TEE HANGER WIRE BY OTHERS 5/8" TYPE X GWB J-BEAD DRYWALL SUSPENSION MAIN TEE, MITEREDOVERLAP & SCREW ATTACH. DO NOT CUTFACE OF TEE WHEN CREATING 90° BEND CHANNEL MOLDING DRYWALL SUSPENSIONTRANSITION CLIP CORNER BEAD ANGLE MOLDING DRYWALL SUSPENSION CROSS TEE 12" MAX. LINEAR LIGHT FIXTURE BRACING, ANGLE MOLDING 4'-0" MAX.ANGLE MOLDING ACOUSTICAL CEILING PANEL APPLY AT JOINT, JOINT COMPOUND AND PAPER JOINT TAPE 5/8" TYPE X GWB NOTE: LINEAR FIXTURE SHALL NOT EXCEED 3 LBS/FT [4.5 Kg/m]6" MAX.HANGER WIRE BY OTHERS DRYWALL SUSPENSIONMAIN TEE DRYWALL SUSPENSIONCROSS TEE HINGE ASSEMBLY ALUMINIUM FRAMED 23-5/8" X 23-5/8" ACCESS PANEL SYSTEM FOR 1/2" THICK DRYWALL PANELS - PROVIDED BY OTHERS. ATTACH FRAME TO BACKSIDE OF PANEL APPLY JOINT FINISH COMPOUND AT ALL PANEL CUTS. FINISH PER INSTALLATION INSTRUCTIONS. INSERT CUT OUT PERFORATED FIELD TO ARTICULATED ACCESS FRAME ASSEMBLY LATCH / TOUCH LATCH ASSEMBLY NOTE: ORDER ACCESS PANEL FLANGE THICKNESS TO WORK WITH 5/8" [15.9] THICK DRYWALL. 5/8" TYPE X GWB ATTACH STABILIZER BARS TO GRID. LOAD OF FIXTURE AND HOUSING TO BE SUPPORTED FROM STRUCTURE ABOVE, TYPICAL TRIM RING RIM CLIPS, DO NOT OVER TIGHTEN DRYWALL SUSPENSION CROSS TEE HANGER WIRE BY OTHERS SUPPORT & BRACE LIGHT FIXTURE TO STRUCTURE ABOVE WITH ANGLES DRYWALL SUSPENSION MAIN TEE DRYWALL SUSPENSION CROSS TEE 5/8" TYPE X GWB DRYWALL SUSPENSION MAIN TEE, MITEREDOVERLAP & SCREW ATTACH. DO NOT CUTFACE OF TEE WHEN CREATING 90° BEND DRYWALL SUSPENSION CROSS TEE DRYWALL SUSPENSION MAIN TEE HANGER WIRE BY OTHERS ANGLE MOLDING TAPE AND FINISH CORNER AS REQUIRED 5/8" TYPE X GWB 3" = 1'-0"1SUS. GWB TO ACT CEILING - TRANSITION CLIP 3" = 1'-0"2SUS. GWB TO ACT CEILING - SHORT JOG WITH REVEAL 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216CEILING- SUSPENDEDGWB TYP. DETAILS A-521 FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 0'2" 4"8" SCALE: 3" = 1'-0" EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV 3" = 1'-0"3SUS. GWB TO ACT CEILING - FLUSH TRANSITION 3" = 1'-0"4SUS. GWB CLNG.- SPRINKLER HEAD 3" = 1'-0"5SUS. GWB TO ACT CEILING - SHORT JOG 3" = 1'-0"6SUS. GWB CLNG.- CANTILEVER W/O BACKLOAD HT. CHANGE 3" = 1'-0"7SUS. GWB CLNG.- CANTILEVER W/ BACKLOAD HT. CHANGE 3" = 1'-0"8 SUS. GWB TO ACT CEILING - LIGHT COVE AT TRANSITION 3" = 1'-0"9 SUS. GWB CLNG.- ACCESS PANEL DETAIL 3" = 1'-0"10 SUS. GWB CLNG.- LED DOWNLIGHT WITH IC HOUSING 3" = 1'-0"11SUS. GWB CLNG.- INSIDE CORNER REVISION SCHEDULE # DESCRIPTION DATE 2 ADDENDUM 2 6/21/2024 FFL W-AW-BW-DW-EHEIGHTWIDTHHEAD HEIGHTW-F WIDTH HEAD HEIGHTHEAD HEIGHTHEIGHTWIDTH HEIGHTHEAD HEIGHTWIDTH HEIGHTWIDTH HEAD HEIGHTHEIGHTSILLHEIGHTSILLHEIGHTSILLHEIGHTHEIGHTSILLHEIGHTSILLSOLID SURFACE SILL ONLY AT GUESTROOMW-CHEIGHTSILL HEIGHTHEAD HEIGHTWIDTH EQEQ W-GHEIGHTSILL HEIGHTHEAD HEIGHTWIDTH EQ EQ INTEGRAL LOUVER, INSTALL PER MANUFACTURER SOLID SURFACE SILL ONLY AT GUESTROOMW-HHEIGHTSILL HEIGHTHEAD HEIGHTWIDTH INTEGRAL LOUVER, INSTALL PER MANUFACTURER SOLID SURFACE SILL ONLY AT GUESTROOMW-JHEIGHTSILL HEIGHTHEAD HEIGHTWIDTH EQ EQ SOLID SURFACE SILL ONLY AT GUESTROOMW-KHEIGHTSILL HEIGHTHEAD HEIGHTWIDTH CW-A1CW-C DT DI 16' - 10" DT DI DTDT DIDI 4' - 3"4' - 2"4' - 2"4' - 3"7' - 1"4' - 1"D-121 DIDIDIDIDI DTDTDTDT 4' - 0 3/4"3' - 11 3/4"4' - 0 3/4" EQ. AEQ. AEQ. AEQ. BEQ. BEQ. BEQ. B 10' - 3 3/4" EQ. A6' - 0" 12' - 1" 4' - 0 3/4"6' - 3" DT DI 10' - 3 3/4" 10' - 3 3/4"7' - 1"4' - 1"CW-A2CW-B EQ. A6' - 0" DI DT11' - 2"11' - 2"CW-D8' - 6 3/4"2' - 7 1/4"EQ EQ DT DT DT DT11' - 2"WIDTH CW-E6' - 1"1' - 11"DT DI 8' - 0"7' - 8 1/2" 3' - 10 1/4"3' - 10 1/4" DI DT CW-F DI DT 5' - 0"4' - 1 1/2"7' - 0 1/2"11' - 2"CW-G2' - 7 1/4"8' - 6 3/4"3' - 3 3/4"3' - 2 3/4" 3' - 3 3/4" DT DT DT DT DT DT11' - 2"9' - 10" CW-H7' - 2"3' - 3" 3' - 0" WIDTH DT 7' - 0"7' - 1"HEIGHTWIDTH 3' - 3" ST ST CW-K7' - 0"3' - 0" 12' - 1" CW-M D-122 DI DIDI 7' - 1"1' - 11"3' - 0 1/4"6' - 0 1/2"3' - 0 1/4"1' - 11"7' - 1"3' - 0 3/4"3' - 0" 3' - 1 1/2" 2' - 11 1/2" CW-N D-122A DI DI DI 12' - 1 3/4" CW-P 7' - 0"2' - 0"3' - 2" DI ST 5' - 5 1/2" CW-J7' - 0"D-139A 3' - 0" 3' - 3"7' - 2"CW-L6' - 11 1/2"7' - 0 1/2"11' - 2"D-101DT DI 5' - 1" 3' - 0" 3' - 3" 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216WINDOW TYPES ANDSCHEDULE A-601 FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 WINDOW SCHEDULE MARKDESCRIPTIONOPERATION LOCATION WINDOWFRAME GLAZING FIRERATINGMAXU-FACTORPF NESW MAXSHGCMINVLTACOUSTICQUANTITY COMMENTSWIDTH HEIGHT HEAD HT. SILL HT. W-A STANDARD 8' WIDE PUBLIC WINDOWFIXED EXTERIOR 8' - 0" 5' - 2" 7' - 2" 2' - 0" ALUM/PC-04 DI NO 0.38 <0.2 W 0.38 0.6 -1 W-B STANDARD 5' WIDE PUBLIC WINDOWFIXED EXTERIOR 5' - 0" 5' - 2" 7' - 2" 2' - 0" ALUM/PC-04 DI NO 0.38 <0.2 S/W 0.38 0.6 -13 W-C STANDARD 4' WIDE PUBLIC WINDOWFIXED EXTERIOR 4' - 0" 5' - 2" 7' - 2" 2' - 0" ALUM/PC-04 DI NO 0.38 <0.2 N/E/S/W 0.38 0.6 -16 W-D 4' WIDE POOL WINDOWFIXED INTERIOR 4' - 0" 8' - 6" 9' - 6" 1' - 0" ALUM/PC-04 ST NO --- - 0.6 -1 W-E 3' WIDE POOL WINDOWFIXED INTERIOR 3' - 0" 8' - 6" 9' - 6" 1' - 0" ALUM/PC-04 ST NO --- - 0.6 -2 W-F KITCHEN HOOD DUCT LOUVERFIXED EXTERIOR <varies><varies><varies> <varies> ALUM/PC-B LOUVER NO --- - - -5 W-GSTANDARD 8' WIDE GUESTROOM WINDOW WITHINTEGRAL LOUVERSFIXED EXTERIOR 8' - 0" 5' - 2" 7' - 2" 2' - 0" ALUM/PC-04 DI NO 0.38 <0.2 N/E/S/W 0.38 0.6 MIN. STC 35 ONSOUTH SIDE55 W-HSTANDARD 5' WIDE GUESTROOM WINDOW WITHINTEGRAL LOUVERSFIXED EXTERIOR 5' - 0" 5' - 2" 7' - 2" 2' - 0" ALUM/PC-04 DI NO 0.38 <0.2 N/E/S/W 0.38 0.6 MIN. STC 35 ONSOUTH SIDE58 W-I KITCHEN HOOD DUCT LOUVERFIXED EXTERIOR 2' - 0" 2' - 0" 12' - 5 3/4" 10' - 53/4"ALUM/PC-B LOUVER NO --- - - -1 W-K STANDARD 5' WIDE GUESTROOM WINDOWFIXED EXTERIOR 5' - 0" 5' - 2" 7' - 2" 2' - 0" ALUM/PC-04 DI NO 0.38 VARIES N/E/S/W 0.38 0.6 MIN. STC 35 ONSOUTH SIDE35 W-L KITCHEN HOOD DUCT LOUVERFIXED EXTERIOR 0' - 10" 0' - 10" 10' - 101/2"10' - 01/2"ALUM/PC-C LOUVER NO --- - - -2 CURTAIN WALL TYPES FFL WINDOW TYPES 1. 2. 3. ALL WINDOW FRAMES AND STOREFRONTS TO BE POWDER-COATED ALUMINUM. VERIFY FINISH FOR POOL STOREFRONT WITH ARCHITECT. ALL FENESTRATION PRODUCTS SHALL BE LABELED WITH RATED U-FACTOR, SHGC, VT AND LEAKAGE RATING.FENESTRATION VALUES ARE NFRC PER MANUFACTURER. WINDOW NOTES FFL CURTAIN WALL SCHEDULE TYPELOCATIONINT/EXT DIMENSIONS FRAME GLAZING FIRE RATING MAX. U FACTORPF NESW MAX. SGHC MIN VLTMIN STC COMMENTSHEIGHT WIDTH CW-A1 LOBBY NORTH WALLEXT. 11' - 2" 10' - 3 3/4" ALUM DT / DI NO0.38 >0.5 N 0.61 0.6 - CW-A2 LOBBY NORTH WALLEXT. 11' - 2" 12' - 1" ALUM DT / DI NO0.38 >0.5 N 0.61 0.6 - CW-B LOBBY NORTH WALLEXT. 11' - 2" 10' - 3 3/4" ALUM DT / DI NO0.38 >0.5 N 0.61 0.6 - CW-C LOBBY NORTH WALLEXT. 11' - 2" 16' - 10" ALUM DT / DI NO0.38 >0.5 N 0.61 0.6 - CW-D LOBBY SOUTH WALLEXT. 11' - 2" 8' - 7 1/2" ALUM DT NO0.38 <0.2 S 0.38 0.6 - CW-D LOBBY SOUTH WALLEXT. 11' - 2" 8' - 7 1/2" ALUM DT NO0.38 >0.5 S 0.61 0.6 - CW-D LOBBY SOUTH WALLEXT. 11' - 2" 9' - 3 1/2" ALUM DT NO0.38 >0.5 S 0.61 0.6 - CW-E LOBBY VESTIBULE EAST EXT WALL EXT. 8' - 0" 8' - 1 1/4" ALUM DT / DI NO0.38 >0.5 E 0.61 0.6 - CW-E LOBBY VESTIBULE WEST EXT WALL EXT. 8' - 0" 8' - 1 1/4" ALUM DT / DI NO0.38 >0.5 W 0.61 0.6 - CW-F POOL EAST WALLEXT. 11' - 2" 5' - 0" ALUM DT / DI NO0.38 <0.2 E 0.38 0.6 - CORROSIVE ENVIRONMENT CW-F POOL WEST WALLEXT. 11' - 2" 5' - 0" ALUM DT / DI NO0.38 <0.2 W 0.38 0.6 - CORROSIVE ENVIRONMENT CW-G POOL NORTH WALLEXT. 11' - 2" 9' - 10" ALUM DT NO0.38 0.2-0.5 N 0.56 0.6 - CORROSIVE ENVIRONMENT CW-H GUEST CORRIDOR TO VESTIBULEEXT. 7' - 2" 6' - 0 3/4" ALUM DT NO0.38 - - - 0.6 - CW-H PUBLIC CORRIDOR TO VESTIBULEEXT. 7' - 2" 5' - 9 1/2" ALUM DT NO0.38 - - - 0.6 - CW-H VESTIBULE WEST WALLEXT. 7' - 2" 5' - 9 1/2" ALUM DT NO0.38 >0.5 W 0.61 0.6 - CW-J PUBLIC TO GUEST CORRIDORINT. 7' - 2" 5' - 9 1/2" ALUM ST NO- - - - 0.6 - CW-K FITNESSINT. 10' - 0" 5' - 8 3/4" ALUM ST NO- - - - 0.6 - CW-K LAUNDRY LOUNGEINT. 10' - 0" 5' - 1 1/4" ALUM ST NO- - - - 0.6 - CW-K MEETING ROOM ENTRYINT. 11' - 0" 7' - 3 1/2" ALUM ST NO- - - - 0.6 MIN 35 ACOUSTIC SYSTEM CW-L POOL EAST WALLEXT. 11' - 2" 5' - 1" ALUM DT / DI NO0.38 <0.2 E 0.38 0.6 - CORROSIVE ENVIRONMENT CW-M LOBBY VESTIBULE EXT DOOREXT. 9' - 0" 12' - 1" ALUM DI NO0.38 >0.5 S 0.61 0.6 - CW-N LOBBY VESTIBULE INT DOOREXT. 9' - 0" 12' - 8 1/2" ALUM DI NO0.38 - - - 0.6 - CW-P LOBBY VESTIBULE EAST CLERESTORY EXT. 2' - 0"3' - 2" ALUM DI NO- - - - 0.6 - CW-P LOBBY VESTIBULE WEST CLERESTORY EXT. 2' - 0"3' - 2" ALUM DI NO- - - - 0.6 - 0'2' 4'8' SCALE: 1/4" = 1'-0" GLAZING LEGEND ••• ••• • DT INSULATED DOUBLE PANE TEMPERED GLASS1/4" CLEAR TEMPERED GLASS1/2" AIRSPACE1/4" CLEAR TEMPERED, LOW "E" GLASS DI INSULATED DOUBLE PANE GLASS 1/4" CLEAR GLASS1/2" AIRSPACE1/4" CLEAR LOW "E" GLASS ST SINGLE PANE TEMPERED GLASS1/4" CLEAR TEMPERED GLASS EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV Revision Schedule Number Description Date D-A WIDTH HEIGHTD-B WIDTH HEIGHTD-C WIDTH HEIGHTD-DHEIGHTWIDTHHEIGHTWIDTH D-EHEIGHTWIDTH D-FD-GHEIGHTWIDTHHEIGHTWIDTH EQEQ D-HD-J7' - 0"VAR.3' - 0" 5' - 0" D-K0' - 6"HEIGHT0' - 6" WIDTH 7' - 0"6' - 0" D-L FFL FFL 3' - 0"3' - 0" #1: GUESTROOM ENTRY DOOR 3 EA. HINGES WITH HEAVY DUTY HINGE PIN STOP1 EA. ELECTRONIC LOCK SET (OWNER-SUPPLIED)1 EA. DOOR GUARD1 EA. TAMPER-PROOF 1-WAY VIEWER WITH SLIDING COVER1 EA. SMOKE SEAL DOOR GASKETING1 EA. STONE THRESHOLD1 EA. DOOR CLOSER WITH SPEED CONTROL1 EA. DOOR DROP #2: GUESTROOM INTERIOR DOOR 3 EA. HINGES1 EA. PRIVACY SET1 EA. WALL STOP #3: GUESTROOM CONNECTING DOOR 3 EA. HYDRAULIC AUTOMATIC HINGES WITH DOOR CLOSER, SPEED CONTROL & HOLD-OPEN FUNCTIONS1 EA. PASSAGE LATCHSET (LOW PROFILE, VERIFY THAT HANDLES WILL NOT CONFLICT WITHIN FRAME DEPTH) 1 EA. DEADBOLT1 EA. SMOKE SEAL DOOR GASKETING1 EA. DOOR DROP1 EA. DOOR GUARD1 EA. COMMUICATING DOOR THRESHOLD #4: INTERIOR SLIDING ENTRY DOOR 1 EA. REMOTE ELECTRONIC LOCKSET INSIDE VESTIBULE (OWNER-SUPPLIED)1 EA. INTERCOM INSIDE VESTIBULEBALANCE OF HARDWARE BY DOOR SUPPLIER #5: EXTERIOR STOREFRONT DOOR 1 EA. REMOTE ELECTRONIC LOCKSET (OWNER-SUPPLIED)BALANCE OF HARDWARE BY DOOR SUPPLIER #6: LOCKSET, CLOSER, WALL STOP 3 EA. HINGES1 EA. ELECTRONIC LOCK SET (OWNER-SUPPLIED)1 EA. DOOR CLOSER1 EA. WALL STOP #7: LOCKSET, DOOR STOP 3 EA. HINGES1 EA. ELECTRONIC LOCK SET (OWNER-SUPPLIED)1 EA. DOOR STOP AT WALL #8: EMPLOYEE ROOM 3 EA. HINGES1 EA. KEY PAD1 EA. DOOR CLOSER1 EA. DOOR VIEWER1 EA. WALL STOP #9: RESTROOM ENTRY DOORS 3 EA. HINGES1 EA. PUSH PLATES1 EA. DOOR CLOSER1 EA. WALL DOOR STOP #10: PASSAGE, DOOR STOP #11: UTILITY DOOR #12: BOH LAUNDRY 3 EA. HINGES1 EA. KEYPAD1 EA. DOOR CLOSER WITH HOLD-OPEN2 EA. ARMOR PLATES1 EA. WALL STOP1 EA. PUSH/PULL PLATES 3 EA. HINGES1 EA. PASSAGE LATCH SET1 EA. DOOR STOP AT WALL 3 EA. HINGES1 EA. LOCK SET1 EA. DOOR CLOSER1 EA. THRESHOLD1 EA. DOOR SWEEP1 EA. WEATHERSTRIPPING1 EA. RAIN DRIP CAP #13: UTILITY EXIT DOOR 3 EA. HINGES1 EA. PANIC HARDWARE EXIT DEVICE1 EA. DOOR CLOSER WITH HOLD-OPEN1 EA. THRESHOLD1 EA. DOOR SWEEP1 EA. WEATHERSTRIPPING1 EA. RAIN DRIP CAP1 EA. KICK PLATE #14: INTERIOR STAIR 3 EA. HINGES1 EA. PANIC HARDWARE EXIT DEVICE1 EA. DOOR CLOSER1 EA. SMOKE SEAL DOOR GASKETING1 EA. WEATHERSTRIPPING1 EA. DOOR DROP1 EA. WALL STOP #15: HOLD OPEN DOUBLE DOOR 6 EA. SWING CLR HINGES1 EA. LATCH SET2 EA. AUTO FLUSH TOP BOLT WITH FIRE PIN1 EA. MEETING STILE1 EA. COORDINATOR2 EA. DOOR CLOSER1 EA. SMOKE SEAL2 EA. MAGNETIC HOLD OPEN TIED TO FIRE ALARM #16: NON-KEYED STOREFRONT DOOR ALL HARDWARE BY DOOR SUPPLIER #17: FOOD PREP DOOR 3 EA. HINGES1 EA. ELECTRONIC LOCK SET (OWNER-SUPPLIED)1 EA. DOOR CLOSER WITH HOLD-OPEN #18: LINEN DISCHARGE DOOR 3 EA. HINGES1 EA. LATCH SET1 EA. DOOR CLOSER1 EA. SMOKE SEAL DOOR GASKETING1 EA. MAGNETIC HOLD OPEN TIED TO FIRE ALARM #19: GUEST CORRIDOR HOLD-OPEN 6 EA. SWING CLR HINGES1 EA. ELECTRONIC LOCK SET (OWNER-SUPPLIED)1 EA. TAMPER-PROOF 1-WAY VIEWER WITH SLIDING COVER1 EA. FLUSH TOP BOLT AT INACTIVE PANEL2 EA. DOOR CLOSER WITH HOLD OPEN1 EA. WALL STOP #21: SERVICE DOUBLE DOOR 6 EA. HINGES1 EA. ELECTRONIC LOCK SET (OWNER-SUPPLIED)1 EA. MEETING STILE2 EA. DOOR CLOSER WITH HOLD-OPEN #20: BALCONY DOOR 3 EA. HINGES WITH HEAVY DUTY HINGE PIN STOP1 EA. NON-KEYED LOCKSET1 EA. WEATHERSTRIPPING1 EA. THRESHOLD1 EA. DOOR SWEEP1 EA. DOOR CLOSER #22: EXTERIOR DOUBLE DOOR 6 EA. HINGES1 EA. REMOTE ELECTRONIC LOCK SET (OWNER-SUPPLIED)1 EA. MEETING STILE2 EA. DOOR CLOSER WITH HOLD-OPEN1 EA. THRESHOLD2 EA. DOOR SWEEP2 EA. WEATHERSTRIPPING2 EA. RAIN DRIP CAP2 EA. KICK PLATE #23: EXTERIOR ENTRY DOOR 3 EA. HINGES1 EA. REMOTE ELECTRONIC LOCK SET (OWNER-SUPPLIED)1 EA. THRESHOLD1 EA. DOOR CLOSER1 EA. DOOR SWEEP1 EA. WEATHERSTRIPPING1 EA. RAIN DRIP CAP #1A: ACCESSIBLE GUESTROOM ENTRY DOOR #1: GUESTROOM ENTRY DOOR HARDWARE SET WITH2 EA. TAMPER-PROOF 1-WAY VIEWER WITH SLIDING COVER #20A: PATIO DOOR #20: BALCONY DOOR HARDWARE SET WITH1 EA. DEADBOLT #7A: LOCKSET, DOOR STOP, ACOUSTIC #7: LOCKSET, DOOR STOP WITH1 EA. SMOKE SEAL DOOR GASKETING1 EA. DOOR DROP 0' - 3"7 0 . 0 0 °3 SECONDSDOOR CLOSER VIEWER - 2 REQUIRED AT ACCESSIBLE ROOMS - PROVIDE TAMPER PROOF 1-WAY VIEWER WITH SLIDING COVER SOLID CORE WOOD DOOR NOTES: VERIFY ALL DIMENSIONS WITH MANUFACTURER/ INDUSTRY STANDARDS/ APPLICABLE CODES. ROOM SIGNAGE DOOR GUARD ELECTRONIC LOCKSET TO TOP OF GUARD4'-0" (MAXIMUM)3' - 4"2 3/4" ACCESSIBLE ONLY3'-7"5'-0" TYPICAL℄℄ ℄ ℄ ACCESSIBLE DOORS: PROVIDE A SMOOTH SURFACE WITHIN 10" AFF VERTICALLY ON THE PUSH SIDE EXTENDING THE FULL WIDTH OF THE DOOR . 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216DOOR TYPES ANDSCHEDULE A-602 FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 FFL DOOR SCHEDULE MARK ROOMINT. /EXT. DOOR FRAME HARDWARE FIRERATING MAX.U-FACTOR ADAREQ'D ACOUSTIC QUANTITY COMMENTSFrom To TYPE HEIGHT WIDTH THICKNESS HANDING MATERIAL FINISH GLAZING MATERIAL FINISH D-001 001 EXT. D-E 7' - 0" 3' - 0" 0' - 1 3/4" LHR GALV. HM PC-B NO GALV. HM PC-B 23 NO 0.37 NO NO 1 KICKPLATE D-001A 001 EXT.7' - 0" 6' - 0" 0' - 3" ROLL-UP INSULATED METAL PC-B NO GALV. HM PC-B 16 NO 0.37 NO NO 1 D-100 100A EXT. D-C 7' - 0" 3' - 0" 0' - 1 3/4" RHR ALUMINUM PC-04 FULL LITE, TI ALUMINUM PC-04 5 NO 0.38 YES NO 1 D-100A 100 100A EXT. D-C 7' - 0" 3' - 0" 0' - 1 3/4" LH ALUMINUM PC-04 FULL LITE, TI ALUMINUM PC-04 19 NO 0.38 YES NO 1 D-101 005 101 EXT. D-C 6' - 11 1/2" 3' - 0" 0' - 1 3/4" LHR ALUMINUM PC-04 FULL LITE, TI ALUMINUM PC-04 5 NO 0.38 YES NO 1 CORROSIVE ENVIRONMENT D-101A 100 101 INT. D-C 7' - 0" 3' - 0" 0' - 1 3/4" RHR FRP PT-11 FULL LITE, SG FRP PT-11 6 NO -YES NO 1 CORROSIVE ENVIRONMENT D-102 102 101 INT. D-G 7' - 0" 3' - 0" 0' - 1 3/4" RH FRP PT-11 NO FRP PT-11 2 NO -YES NO 1 CORROSIVE ENVIRONMENT, KICKPLATE D-103 101 103 INT. D-G 7' - 0" 3' - 0" 0' - 1 3/4" RH FRP PT-11 NO FRP PT-11 7 NO -NO NO 1 CORROSIVE ENVIRONMENT, KICKPLATE D-104 005 104 EXT. D-E 7' - 0" 4' - 6" 0' - 1 3/4" RHR GALV. HM PC-B NO GALV. HM PC-B 13 NO 0.37 NO NO 1 D-104A 104 100 INT. D-G 7' - 0" 3' - 0" 0' - 1 3/4" RHRA SCW PF-11 NO KD PF-11 6 NO -NO NO 1 D-105 100 105 INT. D-G 7' - 0" 3' - 6" 0' - 1 3/4" LH SCW PF-11 NO KD PF-11 12 NO -YES NO 1 KICKPLATE EXTENDING TO BOTTOM OF DOORHANDLE D-105A 104 105A INT. D-G 7' - 0" 2' - 6" 0' - 1 3/4" LH HM PC-03 NO KD PF-03 10 1.5 HR -NO NO 1 D-106 100 106 INT. D-G 7' - 0" 3' - 0" 0' - 1 3/4" LH HM PC-11 NO KD PF-11 14 1.5 HR -YES NO 1 KICKPLATE D-106A 106 EXT. D-E 7' - 0" 3' - 0" 0' - 1 3/4" LHR GALV. HM PC-B NO GALV. HM PC-B 13 1.5 HR 0.37 YES NO 1 D-107 105 107 INT. D-E 7' - 0" 3' - 6" 0' - 1 3/4" RHR HM PC-03 NO KD PF-03 18 1.5 HR -NO NO 1 KICKPLATE EXTENDING TO BOTTOM OF DOORHANDLE D-108 100 108 INT. D-G 7' - 0" 3' - 0" 0' - 1 3/4" RH SCW PF-11 NO KD PF-11 6 NO -NO NO 1 KICKPLATE D-108A 108 EXT. D-E 7' - 0" 4' - 6" 0' - 1 3/4" LHR GALV. HM PC-B NO GALV. HM PC-B 11 NO 0.37 NO NO 1 D-109 105 109A INT. D-G 7' - 0" 3' - 0" 0' - 1 3/4" LH SCW PF-03 NO KD PF-03 10 NO -YES NO 1 KICKPLATE EXTENDING TO BOTTOM OF DOORHANDLE D-110 100 110 INT. D-G 7' - 0" 3' - 0" 0' - 1 3/4" LH SCW PF-11 NO KD PF-11 8 NO -YES NO 1 D-110A 110 110A INT. D-G 7' - 0" 3' - 0" 0' - 1 3/4" RH SCW PF-03 NO KD PF-03 2 NO -YES NO 1 D-110B 110 110B INT. D-G 7' - 0" 3' - 0" 0' - 1 3/4" LH SCW PF-03 NO KD PF-03 2 NO -NO NO 1 D-112 100 112 INT. D-C 7' - 0" 3' - 0" 0' - 1 3/4" LH ALUMINUM PC-11 FULL LITE, SG ALUMINUM PC-11 6 NO -YES NO 1 D-114 100 114 INT. D-C 7' - 0" 3' - 0" 0' - 1 3/4" RH ALUMINUM PC-11 FULL LITE, SG ALUMINUM PC-11 6 NO -YES NO 1 D-115 118 115 INT. D-G 7' - 0" 3' - 0" 0' - 1 3/4" LH SCW PF-11 NO KD PF-11 9 NO -YES NO 1 D-116 118 116 INT. D-G 7' - 0" 3' - 0" 0' - 1 3/4" RH SCW PF-11 NO KD PF-11 9 NO -YES NO 1 D-117 005 117 EXT. D-D 7' - 0" 3' - 0" 0' - 1 3/4" LHR GALV. HM PC-04 FULL DIVIDED LITE, TI GALV.HM PC-04 5 NO 0.38 YES NO 1 D-119 120 119 INT. D-H 7' - 0" 6' - 0" 0' - 1 3/4" RHRA SCW PF-11 NO KD PF-11 21 NO -NO NO 1 D-120 100 120 INT. D-C 7' - 0" 3' - 0" 0' - 1 3/4" LH ALUMINUM PC-04 FULL LITE, SG ALUMINUM PC-04 6 NO -YES YES 1 D-121 005 121 EXT. D-B 7' - 0" 6' - 0" 0' - 1 3/4" RHRA ALUMINUM PC-04 FULL LITE, TI ALUMINUM PC-04 5 NO 0.38 YES NO 1 D-122 006 122 EXT. D-A 7' - 0" 12' - 1" 0' - 1 3/4" OXXO ALUMINUM PC-04 FULL LITE, TI ALUMINUM PC-04 16 NO 0.38 YES NO 1 D-122A 122 121 EXT. D-A 7' - 0" 12' - 1 3/4" 0' - 1 3/4" OXXO ALUMINUM PC-04 FULL LITE, TI ALUMINUM PC-04 4 NO 0.38 YES NO 1 D-123 121A 123 INT. D-G 7' - 0" 3' - 6" 0' - 1 3/4" LH SCW PF-11 NO KD PF-11 17 NO -YES NO 1 KICKPLATE D-124 121A 124 INT. D-G 7' - 0" 3' - 0" 0' - 1 3/4" RH SCW PF-11 NO KD PF-11 7 NO -YES NO 1 D-125 124 125 INT. D-K 7' - 0" 3' - 0" 0' - 1 3/4" LH SCW PF-03 VISION LITE, SG KD PF-03 7A NO -YES YES 1 D-126 124 126 INT. D-K 7' - 0" 3' - 0" 0' - 1 3/4" RH SCW PF-03 VISION LITE, SG KD PF-03 7A NO -YES YES 1 D-127 124 127 INT. D-K 7' - 0" 3' - 0" 0' - 1 3/4" RH SCW PF-03 VISION LITE, SG KD PF-03 7A NO -YES YES 1 D-128 121A 128 INT. D-G 7' - 0" 3' - 0" 0' - 1 3/4" LH SCW PF-11 NO KD PF-11 6 NO -NO NO 1 D-132 132 EXT. D-E 7' - 0" 3' - 0" 0' - 1 3/4" LHR GALV. HM PC-E NO GALV. HM PC-E 13 NO 0.37 YES NO 1 D-139 121A 139 INT. D-C 7' - 0" 3' - 0" 0' - 1 3/4" LH ALUMINUM PC-04 FULL LITE, SG ALUMINUM PC-04 19 20 MIN -YES NO 1 D-139A 139 139A INT. D-C 7' - 0" 3' - 0" 0' - 1 3/4" LH ALUMINUM PC-04 FULL LITE, SG ALUMINUM PC-04 16 20 MIN -YES NO 1 D-139B 139A EXT. D-D 7' - 0" 3' - 0" 0' - 1 3/4" RHR GALV. HM PC-04 FULL DIVIDED LITE, TI GALV. HM PC-04 23 NO 0.38 YES NO 1 D-141 141 EXT. D-L 7' - 0" 6' - 0" 0' - 1 3/4" RHRA GALV. HM PC-B NO GALV. HM PC-B 22 NO -YES NO 1 D-207 207 209 INT. D-H 7' - 0" 6' - 0" 0' - 1 3/4" RHRA SCW PF-03 NO KD PF-03 21 NO -YES NO 1 KICKPLATE D-207A 207 207A INT. D-G 7' - 0" 3' - 0" 0' - 1 3/4" LH SCW PF-03 NO KD PF-03 7 NO -NO NO 1 D-207B 215 207 INT. D-G 7' - 0" 3' - 6" 0' - 1 3/4" LH SCW PF-11 NO KD PF-11 7 NO -YES NO 1 KICKPLATE D-532 532 539 INT. D-G 7' - 0" 3' - 0" 0' - 1 3/4" LHR SCW PF-11 NO KD PF-11 7 NO -NO NO 1 KICKPLATE GUEST ROOM DOOR SCHEDULE MARKDESCRIPTION INT. /EXT. DOOR FRAME HARDWARE FIRERATING MAX. UFACTOR ADA REQ'D ACOUSTIC COMMENTSTYPE HEIGHT WIDTH THICKNESS HANDING MATERIAL FINISH GLAZING MATERIAL FINISH D-G01 TYPICAL GUEST ROOM ENTRY DOOR INT. D-G 7' - 0" 3' - 0" 0' - 1 3/4" LH/RH SCW PL-01 NO KD PF-11 1 20 MIN -32" CLR YES D-G01A TYPICAL ADA GUEST ROOM ENTRY DOOR INT. D-G 7' - 0" 3' - 0" 0' - 1 3/4" LH/RH SCW PL-01 NO KD PF-11 1A 20 MIN -YES YES D-G02 TYPICAL GUEST ROOM CONNECTING DOOR INT. D-G 7' - 0" 3' - 0" 0' - 1 3/4" LHR/RHR SCW PF-03 NO KD PF-03 3 20 MIN -32" CLR YES 2 DOORS PER FRAME D-G02A TYPICAL ADA GUEST ROOM CONNECTING DOOR INT. D-G 7' - 0" 3' - 0" 0' - 1 3/4" LHR/RHR SCW PF-03 NO KD PF-03 3 20 MIN - ON SIDE WITHADA ROOM YES 2 DOORS PER FRAME D-G03 TYPICAL GUEST ROOM BATHROOM DOOR INT. D-G 7' - 0" 3' - 0" 0' - 1 3/4" LH/RH SCW PF-03 NO KD PF-03 2 NO -32" CLR - D-G03A TYPICAL ADA GUEST ROOM BATHROOM DOOR INT. D-G 7' - 0" 3' - 0" 0' - 1 3/4" LH/RH SCW PF-03 NO KD PF-03 2 NO -YES - D-G04 TYPICAL GUEST ROOM BALCONY DOOR EXT. D-F 7' - 0" 3' - 0" 0' - 1 3/4" LH/RH GALV. HM PC-04 YES- W/ INT. BLIND GALV. HM PC-04 20 NO 0.38 32" CLR YES 20A HARDWARE SET AT 1STFLOOR PATIO DOORS D-G04A TYPICAL ADA GUEST ROOM BALCONY DOOR EXT. D-F 7' - 0" 3' - 0" 0' - 1 3/4" RH GALV. HM PC-04 YES- W/ INT. BLIND GALV. HM PC-04 20 NO 0.38 YES YES D-G05 TYPICAL KING 1-BEDROOM INTERIOR DOOR INT. D-G 7' - 0" 3' - 0" 0' - 1 3/4" LH/RH SCW PF-03 NO KD PF-03 2 NO -32" CLR - D-G05A TYPICAL ADA KING 1-BEDROOM INTERIOR DOOR INT. D-G 7' - 0" 3' - 0" 0' - 1 3/4" LH SCW PF-03 NO KD PF-03 2 NO -YES - TYPICAL DOOR SCHEDULE MarkDESCRIPTION INT. / EXT. DOOR FRAME HARDWARE FIRE RATING MAX. U-FACTOR ADA REQ'D ACOUSTIC COMMENTSTYPE HEIGHT WIDTH THICKNESS HANDING MATERIAL FINISH GLAZING MATERIAL FINISH D-X06 STAIR DOOR FROM CORRIDOR INT. D-G 7' - 0" 3' - 0" 0' - 1 3/4" RH HM PC-11 NO KD PF-11 14 1.5 HR -YES NO KICKPLATE D-X09 LINEN ROOM DOORINT. D-G 7' - 0" 4' - 0" 0' - 1 3/4" LH SCW PF-11 NO KD PF-11 8 NO -NO NO KICKPLATE EXTENDING TO BOTTOM OF DOOR HANDLE D-X09B IDF CLOSET DOORINT. D-G 7' - 0" 2' - 4" 0' - 1 3/4" RHR SCW PF-03 NO KD PF-03 7 NO -NO NO D-X09C DAC CLOSET DOORINT. D-G 7' - 0" 2' - 4" 0' - 1 3/4" RHR SCW PF-03 NO KD PF-03 7 NO -NO NO D-X11 ELEVATOR DOORINT.7' - 0" 3' - 6"RH ELEV. SS SS NO SS CLEAR ELEV. 1.5 HR -YES NO D-X11A ELEVATOR DOORINT.7' - 0" 3' - 6"RH ELEV. SS SS NO SS CLEAR ELEV. 1.5 HR -YES NO D-X13 ELEVATOR DOORINT.7' - 0" 3' - 6"LH ELEV. SS SS NO SS CLEAR ELEV. 1.5 HR -YES NO D-X15 ELECTRICAL CLOSET DOORINT. D-H 7' - 0" 5' - 0" 0' - 1 3/4" RHRA SCW PF-11 NO KD PF-11 21 NO -NO NO D-X15B ROOM GROUP LOCK-OUT DOORS INT. D-J 7' - 0" 5' - 0" 0' - 1 3/4" RHR SCW PF-15 NO KD PF-15 19 NO -YES NO D-X17 ELEVATOR LOBBY FIRE DOORS INT. D-H 7' - 0" 6' - 0" 0' - 1 3/4" RHRA SCW PF-15 NO KD PF-15 15 1.5 HR -YES NO D-X32 STAIR DOOR FROM CORRIDOR INT. D-G 7' - 0" 3' - 0" 0' - 1 3/4" LH HM PC-11 NO KD PF-11 14 1.5 HR -YES NO KICKPLATE 1.2.3.4.5.6.7.8.9.10.11.12.13. 14.15.16.17. 18. 19.20. REFER TO HOMEWOOD SUITES BY HILTON BRAND STANDARDS FOR ADDITIONAL TECHNICAL CRITERIA FOR DOORS, WINDOWS, FRAMES AND HARDWAREUSE KNOCK-DOWN DOOR FRAMES, TIMELY OR EQUIVALENT.PROVIDE 5 INCH STILES ON ALL DOORS AND/OR WINDOWS WHERE CARD READERS WILL BE MOUNTED.PROVIDE ACOUSTIC GASKETS AROUND ALL GUESTROOM DOORS.FOR DOORS IN POOL ROOM AND POOL SERVICE ROOMS: USE SEALANTS, MATERIALS AND FINISHES THAT ARE RATED FOR WET AND CORROSIVE ENVIRONMENTS.ALL DOOR AND FRAME FIRE RATINGS SHALL BE IN COMPLIANCE WITH LOCAL CODES AND JURISDICTIONSPROVIDE SMOKE SEALS/GASKETING WHERE REQUIREDPROVIDE WALL STOPS FOR ALL DOORS, UNLESS NOTED OTHERWISEPROVIDE WEATHERSTRIPPING AND THRESHOLD AT ALL EXTERIOR DOORS AS REQUIREDPROVIDE KICKPLATES WHERE REQUIREDDOOR SECURITY HARDWARE TO BE COORDINATE WITH SECURITY CONSULTANT; FINAL KEYING AND FUNCTION TO BE COORDINATED WITH OWNERPROVIDE SILENCERS ON ALL DOORS WITHOUT WEATHER STRIPPING OR SEALSACCESSIBLE DOORS: PROVIDE A SMOOTH SURFACE WITHIN 10" AFF VERTICALLY ON THE PUSH SIDE EXTENDING THE FULL WIDTH OF THE DOOR OR GATE - NOT REQUIRED FOR THE SLIDING DOORS. TEMPERED GLASS DOORS WITHOUT STILES AND HAVING A BOTTOM RAIL OR SHOE WITH THE TOP LEADING EDGE TAPERED AT 60 DEGREES MIN FROM THE HORIZONTAL ARE NOT REQUIRED TO MEET THE 10" BOTTOM SMOOTH SURFACE HEIGHT. ALL DOORS SHOULD HAVE A DOOR FORCE REQUIRED TO OPEN THE DOOR OF 5 LBS MAX. PROVIDE AN AUTOMATIC DOOR OPENER WITH STANDBY POWER TO OPERATE DOORS.FIRE RATED DOORS SHALL COMPLY WITH THE LOCAL FIRE AUTHORITY FOR FORCE REQUIRED TO OPEN THE DOOR IF NOT AT 5 LBS. PROVIDE ACCESIBLE REMOTE CARD READERS AT ALL EXTERIOR ENTRANCE DOORS, INCLUDING MAIN ENTRY, FITNESS CENTER, GUEST LAUNDRY AND INDOOR POOL. ALL DOOR FRAMES MUST HAVE A 32" MINIMUM CLEAR WIDTH OPENING WHEN DOOR IS FULLY OPEN. THRESHOLDS AT ACCESSIBLE DOORS TO MEET ALL APPROPRIATE ACCESSIBILITY REQUIREMENTS. ACCESSIBLE DOORS INCLUDE ALL PUBLIC ACCESS SPACES, ALL PUBLIC EXTERIOR DOORS, ALL EGRESS DOORS AND EMPLOYEE DOORS THAT ARE INDICATED WITH A CLEAR FLOOR AREA.EACH DOOR SUB-CONTRACTOR (ALUM. STOREFRONT/WOOD/HOLLOW METAL) SHALL BE RESPONSIBLE TO ADJUST ALL INTERIOR DOORS SO THAT THE DOORS REQUIRED OPENING FORCE IS 5 LBS OR LESS. ANY DOOR WITH A CLOSER SHALL BE ADJUSTED TO SLOW THE CLOSING TIME TO A MINIMUM OF 3 SECONDS, BUT NO MORE THAN 4 SECONDS FROM A STARTING POINT OF 70 DEGREES OPEN 3" FROM CLOSING. HARDWARE SHALL BE SELECTED TO ALLOW FOR CLOSING SPEED REQUIREMENTS FOR ACCESSIBLITY - REFER TO DIAGRAM. CHANGES IN LEVEL AT FLOOR TRANSITION PERMITTED TO BE 1/4" MAXIMUM OR 1/2" W/ 1:2 SLOPE (TYPICAL, ALL THRESHOLDS).ALL ELECTRONIC DOOR LOCKS TO BE OWNER-SUPPLIED. DOOR NOTES HARDWARE SCHEDULE DOOR TYPES 1/2" = 1'-0"2 CLOSING DIAGRAM GLAZING/FINISH LEGENDTI INSULATED DOUBLE PANE TEMPERED GLASSSG SINGLE PANE TEMPERED GLASSDG DOUBLE PANE TEMPERED GLASS FRP FIBER REINFORCED POLYMERGALV HM GALVANIZED HOLLOW METALHM HOLLOW METAL KD KNOCK-DOWN PREFINISH FRAMEPC POWDER-COATEDPF PRE-FINISHED PL PLASTIC LAMINATEPT PAINTSCW SOLID CORE WOOD 3/8" = 1'-0"1ELEVATION AT GUEST ROOM ENTRY DOOR 0'1' 2'4' SCALE: 1/2" = 1'-0" 0'1'-4" 2'-8"5''-4" SCALE: 3/8" = 1'-0" EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV REVISION SCHEDULE # DESCRIPTION DATE 2 ADDENDUM 2 6/21/2024 2 2 2 22 2 2 ACTACOUSTIC CEILING TILEASALUMINUM STOREFRONTCGCORNER GUARDCONC CONCRETE, UNFINISHEDCPCARPETCPTCARPET TILECSCONCRETE, FINISHEDGWBGYPSUM WALL BOARDFCFIBER CEMENTFRPFIBERGLASS-REINFORCEDPLASTICMR GWB MOISTURE-RESISTANT GWBPFPRE-FINISHED DOORPLPLASTIC LAMINATEPTPAINT/POWDER COATQTQUARRY TILERBRUBBER BASERESRESILIENT TILE FLOORSCSTAMPED CONCRETESFSPECIALTY FINISH (KNOCK DOWN)SSENGINEERED SOLID SURFACESTSTONESTLSTAINLESS STEELSTRUC STRUCTURE ABOVEVCTVINYL COMPOSITE TILEWCVINYL WALL COVERINGWDWOOD-LOOK ALUMINUM SLATS AND BATTENSWPSCREEN WALL NOTE: REFER TO FF&E PACKAGE AND SPECIFICATION BOOK FOR FURNITURE AND FINISH SPECIFICATIONS FINISH LEGEND 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216ROOM FINISHSCHEDULE A-603 FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 ROOM FINISH SCHEDULE ROOM FLOOR BASE WALLCEILING COMMENTSNO.NAMEMATERIAL FINISH MATERIAL FINISH HEIGHT 01. PUBLIC 100 PUBLIC CORRIDORCPTRB GWBPT GWBPT 10' - 0" 100A VESTIBULECT AS/RB AS/MR GWB AS / PT MR GWB PT 9' - 0" 101 POOL & SPLASH PAD CT/RES CT MR GWB PT MR GWB PT VARIES 102 POOL RESTROOMCTCT MR GWB CT MR GWB PT 9' - 0" 111 ELEV 1CTCT SHAFT STL GWBSTL 7' - 9" 112 LAUNDRY LOUNGECTCT MR GWB WC ACTACT 9' - 0" 113 ELEV 2CTCT SHAFT STL GWBSTL 7' - 9" 114 FITNESSRES RB GWB WC / PT ACT/GWB ACT/PT VARIES 115 WOMEN'S RESTROOMCTCT MR GWB WC / CT MR GWB PT 9' - 0" 116 MEN'S RESTROOMCTCT MR GWB WC / CT MR GWB PT 9' - 0" 118 GUEST STORAGECTRB GWBWC ACT/GWB ACT/PT VARIES 119 MEETING STORAGEVCTRB GWBPT GWB STRUC STRUC 120 MEETING ROOMCPTPT GWB WC / PT ACTACT 11' - 6" 121 LOBBYCT / CPT CT/RB GWB WC,SS,CT,PT ACT/GWB ACT/PT / PL VARIES 121A PUBLIC CORRIDORCTRB GWBPT GWBPT 10' - 0" 122 VESTIBULECTCT AS/MR GWB AS/PT MR GWB PT 9' - 0" 139 GUEST CORRIDORCPTRB GWBPTACTACT 8' - 6" 139A VESTIBULECT AS/CT AS/MR GWB AS / PT ACTACT 8' - 6" X00 CONNECTING CORRIDOR CPTRB GWBPTACTACT 8' - 0" X15 GUEST CORRIDORCPTRB GWBPTACTACT 8' - 0" X17 ELEVATOR LOBBYCPTRB GWBPT GWBPT 8' - 6" 02. BOH 103 POOL MEPCONC RB MR GWB PT MR GWB PT 10' - 0" 104 ELECTRICALCONC RB MR GWB PT CONC STRUC STRUC 105 BOH LAUNDRYVCTRB MR GWB PTACTACT 10' - 0" 105A BOH DRYERSCONC RB MR GWB PT GWBPT 10' - 0" 107 LINEN DISCHARGE &SORTINGVCTRB GWBPT GWBPT 10' - 0" 108 WATER HEATER & FIRE CONC RB MR GWB PT STRUC PT STRUC 109 LINEN STORAGEVCTRB GWBPT GWBPT 10' - 0" 109A HOUSEKEEPING OFFICE VCTRB GWBPTACTACT 10' - 0" 110 EMPLOYEE ROOMVCTRB GWBWC ACTACT 9' - 0" 110A EMP RR ADACTCT MR GWB WC / CT MR GWB PT 9' - 0" 110B EMP RRCTCT MR GWB WC / CT MR GWB PT 9' - 0" 123 FOOD PREPQTQT MR GWB FRP ACTACT 11' - 0" 124 OPEN OFFICECPTRB GWBPTACTACT 9' - 0" 125 GM OFFICECPTRB GWBPTACTACT 9' - 0" 126 SALES OFFICECPTRB GWBPTACTACT 9' - 0" 127 OWNER'S OFFICECPTRB GWBPTACTACT 9' - 0" 128 ELECTRICALCONC RB GWBPT STRUC PT STRUC 139B ELECTRICALCPTRB GWBPT GWBPT 9' - 0" 140 LINEN CHUTECONC- SHAFT-GWB STRUC SHAFT 141 COURTYARD STORAGE CONC RB MR GWB PT STRUC PT STRUC 207 ENGINEERING OFFICE &STORAGEVCTRB GWBPT GWBPT 9' - 0" 207A PBX/MDFVCTRB GWBPT GWBPT 9' - 0" X06 STAIR 1CPTRB GWBPT GWBSF STRUC X09 LINENS & HOUSEKEEPING VCTRB GWBPT GWBPT 9' - 0" X09A PANELSVCTRB GWBPT GWBPT 9' - 0" X09B IDFVCTRB GWBPT GWBPT 9' - 0" X09C DACVCTRB GWBPT GWBPT 9' - 0" X15A ELECTRICALCPTRB GWBPT GWBPT 8' - 0" X17 ELEVATOR LOBBYCPTRB MR GWB WC MR GWB PT 10' - 0" X32 STAIR 2CPTRB GWBPT GWBSF STRUC GUEST ROOM FINISH SCHEDULE GR ROOM NAME FLOOR BASE WALLCEILING COMMENTSROOMMATERIAL FINISH MATERIAL FINISH HEIGHT ACCESSIBLE GUEST SUITE - KING 1-BEDROOM LIVING AREARES / CPT RBGWB SF / WC GWB PT SMOOTH 8' - 0" NOTES, 1, 12 BEDROOMCPTRBGWB SF / WC GWB PT SMOOTH 8' - 0" NOTES, 1, 12 KITCHEN / DININGRESRB MR GWB WCGWB PT SMOOTH 8' - 0" NOTES, 1, 12 BATHROOMCTCT MR GWB WC MR GWB PT SMOOTH 7' - 6" NOTE 12 ACCESSIBLE GUEST SUITE - STUDIO/EFFICIENCY LIVING AREA/SLEEPING AREARES / CPT RBGWB SF / WC GWB PT SMOOTH 8' - 0" NOTES, 1, 12 KITCHEN / DININGRESRB MR GWB WCGWB PT SMOOTH 8' - 0" NOTES, 1, 12 BATHROOMCTCT MR GWB WC MR GWB PT SMOOTH 7' - 6" NOTE 12 BALCONY/LANAI BALCONY/LANAICONC- EXTERIOR -FCPT8' - 0" TYPICAL/ENLARGED GUEST SUITE - KING 1-BEDROOM LIVING AREARES / CPT RBGWB SF / WC GWB PT SMOOTH 8' - 0" NOTES, 1, 12 BEDROOMCPTRBGWB SF / WC GWB PT SMOOTH 8' - 0" NOTES, 1, 12 KITCHEN / DININGRESRB MR GWB WCGWB PT SMOOTH 8' - 0" NOTES, 1, 12 BATH/TOILETCTCT MR GWB WC MR GWB PT SMOOTH 7' - 6" NOTE 12 DRESSING AREA/LAVATORYCTCT MR GWB WC MR GWB PT SMOOTH 7' - 6" NOTE 12 TYPICAL/ENLARGED GUEST SUITE - STUDIO/EFFICIENCY LIVING AREA/SLEEPING AREARES / CPT RBGWB SF / WC GWB PT SMOOTH 8' - 0" NOTES, 1, 12 KITCHEN / DININGRESRB MR GWB WCGWB PT SMOOTH 8' - 0" NOTES 1, 12 BATH/TOILETCTCT MR GWB WC MR GWB PT SMOOTH 7' - 6" NOTE 12 DRESSING AREA/LAVATORYCTCT MR GWB WC MR GWB PT SMOOTH 7' - 6" NOTE 12 EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV REVISION SCHEDULE # DESCRIPTION DATE 2 ADDENDUM 2 6/21/2024 2 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216FINISH SCHEDULE A-604 FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV REVISION SCHEDULE # DESCRIPTION DATE 2 ADDENDUM 2 6/21/2024 XW-G ALUMINUM CLADDINGEXTERIOR ALUMINUM WOOD-LOOK CLADDINGKNOTWOOD6" CLADDING SYSTEMWESTERN RED CEDAR SPECIFICATION BOOK XS-H RETAINING WALL BLOCKS SITE RETAINING WALLSVERTI-BLOCKCANYON LEGE TEXTURETAUPE (VERIFY WITH ARCHITECT)CONTRACTOR-SUPPLIED SPEC XS-F STONE VENEEREXTERIOR STONE VENEERCULTURED STONECOUNTRY LEDGESTONEASHFALL 1.75" THICK NOMINAL SPECIFICATION BOOK XE-E EIFSEXTERIOR EIFS FINISHPER CONTRACTORFINE-TEXTURED FINISHMATCH PT-E SPECIFICATION BOOK XE-D EIFSEXTERIOR EIFS FINISHPER CONTRACTORFINE-TEXTURED FINISHMATCH PT-D SPECIFICATION BOOK XE-C EIFSEXTERIOR EIFS FINISHPER CONTRACTORFINE-TEXTURED FINISHMATCH PT-C SPECIFICATION BOOK XE-B EIFSEXTERIOR EIFS FINISHPER CONTRACTORFINE-TEXTURED FINISHMATCH PT-B SPECIFICATION BOOK XE-A EIFSEXTERIOR EIFS FINISHPER CONTRACTORFINE-TEXTURED FINISHMATCH PT-A SPECIFICATION BOOK WP-01 LOBBY SCREEN WALLLOBBY PARTITION SCREENSCORONA GROUPINTERSECTIONMATCH: FRAME: PC-04; SLATS: PL-01 45.75" X 8' OR 4' HIGH FINISH SPEC CHOICES WD-10 ALUMINUM WOOD-LOOKOUTDOOR TRELLISES, RECEPTION CLOUD, COLUMN COVERSKNOTWOODSLATS, BEAMS, BATTENSWESTERN RED CEDAR MATCH FINISH FOR COLUMN COVERS DETAILS WD-03 WOOD VENEERSTAIN GRADE WOOD VENEER - DARKSOLID WOODSTAIN GRADE WOOD VENEERRIFT SAWN WHITE OAK MATCH PL-04 SATIN TRANSPARENT STAIN SHEEN LEVEL OF 40 GU FINISH SPEC CHOICES WD-02 WOOD VENEERSTAIN GRADE WOOD VENEER - CREAMSOLID WOODSTAIN GRADE WOOD VENEERRIFT SAWN WHITE OAK MATCH PL-03 SATIN TRANSPARENT STAIN SHEEN LEVEL OF 40 GU FINISH SPEC CHOICES WD-01 WOOD VENEERSTAIN GRADE WOOD VENEER - LIGHTSOLID WOODSTAIN GRADE WOOD VENEERRIFT SAWN WHITE OAK MATCH PL-01 SATIN TRANSPARENT STAIN SHEEN LEVEL OF 40 GU FINISH SPEC CHOICES WC-15 WALLCOVERINGPUBLIC RESTROOMMOMENTUM TEXTILE & WALLCOVERING DIVINEY47632DVZINC 52" OR 54" WIDE MILDEW RESISTANT ADHESIVE CG-15 FINISH SPEC CHOICES WC-14 WALLCOVERINGGUEST LAUNDRYMOMENTUM TEXTILE & WALLCOVERING GRANARY SQUAREGOH 31981836TEAL 54" WIDE MILDEW RESISTANT ADHESIVE CG-14 FINISH SPEC CHOICES WC-13 WALLCOVERINGFITNESSMOMENTUM TEXTILE & WALLCOVERING AVATARHLTN3104STORM FRONT 54" WIDE MILDEW RESISTANT ADHESIVE CG-13 FINISH SPEC CHOICES WC-12 WALLCOVERINGCENTRAL HUBMOMENTUM TEXTILE & WALLCOVERING CONCOURSEGOH 31846883SAND 54" WIDE MILDEW RESISTANT ADHESIVE CG-12 FINISH SPEC CHOICES WC-11 WALLCOVERINGGUEST CORRIDOR DOOR DROP, CENTRAL HUB ACCENT, MEETING ROOM ACCENT MOMENTUM TEXTILE & WALLCOVERING ANGLES MAXY47616AMDEEP SCARLET 52" WIDE MILDEW RESISTANT ADHESIVE CG-11 FINISH SPEC CHOICES WC-10 WALLCOVERINGGUEST CORRIDOR AND MEETING ROOM MAINMOMENTUM TEXTILE & WALLCOVERING WATERCOLOR CANVASY47689WCSTONE 52" OR 54" WIDE MILDEW RESISTANT ADHESIVE CG-10 FINISH SPEC CHOICES WC-02 WALLCOVERINGGUEST SUITE BATHROOM (TOILET AREA)MOMENTUM TEXTILE & WALLCOVERING REFLECTIONSHLTN3101RMORNING AIR 52" WIDE MILDEW RESISTANT ADHESIVE CG-02 FINISH SPEC CHOICES WC-01 WALLCOVERINGGUEST SUITE, BATHROOM (DRESSING AREA)MOMENTUM TEXTILE & WALLCOVERING HOMEWOOD SUITES CUSTOMHMW-201CUSTOM 54" WIDE MILDEW RESISTANT ADHESIVE CG-01 FINISH SPEC CHOICES VCT-01 VINYL COMPOSITION TILE EMPLOYEE ROOM???, BACK OF HOUSE ON FLOORS 2-5TARKETTTARKETT VCT II557- SHOOTING STAR 12"X12"FINISH SPEC CHOICES TS-03 TRANSITION STRIPSTAIRSTARKETTJOHNSONITE STAIR NOSINGSLN-XX-A38- PEWTER 1/4" MATERIAL MATERIAL ON STEP AND RISER PT-14 TS-02 TRANSITION STRIPPUBLIC CARPETSPROLIFITECTRANSITIONSBRUSHED TITANIUM ALUMINUM FINISH SPEC CHOICES TS-01 TRANSITION STRIPGUESTROOM CARPETSTARKETTSLIM LINE TRANSITIONSSLT-29-A29- MOON ROCK FINISH SPEC CHOICES STL STAINLESS STEELCABINETS AND EQUIPMENT FF&E SPECS ST-01 STONEGUEST SUITE ENTRY DOOR THRESHOLDDAL-TILEMARBLEM701- CARRARA WHITE 2"X36"X3/8"POLISHED DOUBLE BEVEL EDGE FINISH SPEC CHOICES SS-10 SOLID SURFACECOUNTERTOP AT OUTDOOR KITCHENDAL-TILEQUARTZNQ52- GREY VELVET 2MM THICK POLISHED SQUARE EDGE FINISH SPEC CHOICES SS-02 SOLID SURFACEGUEST SUITE WINDOWSILLDAL-TILEQUARTZNQ47- WHITE SAND 2MM THICK POLISHED SQUARE EDGE FINISH SPEC CHOICES SS-01 SOLID SURFACEGUEST SUITE AND PUBLIC SPACE COUNTERTOPS AND ES LOW WALL TOPDAL-TILEQUARTZOQ48- INDEPENDENCE CALCUTTA 2MM THICK POLISHED SQUARE EDGE FINISH SPEC CHOICES SF-01 KNOCK-DOWN FINISHGUEST SUITE EXTERIOR WALLSHERWIN-WILLIAMS100% ACRYLIC KNOCK-DOWN FINISH SW7042SHOJI WHITE EGGSHELL MIN 1 COAT PRIMER, 2 COATS PAINT FINISH SPEC CHOICES SC-01 STAMPED CONCRETEEXTERIOR CONCRETE SURFACES AT PORTE COCHERE AND COURTYARDSCOFIELD/SIKASLATE/STONE TEXTUREOWNER TBD - RES-13 RESILIENT FLOORINGSPLASH PAD (SPLASH PAD PERIMETER)LIFE FLOOR3/8" THICK TILE-GX.30 - FOGHORN 12"X24"X3/8"PATTERN - SLATE FINISH SPEC CHOICES RES-12 RESILIENT FLOORINGSPLASH PAD (SPLASH PAD AREA)LIFE FLOOR3/8" THICK TILE-TX.30 - AQUA 12"X24"X3/8"PATTERN - RIPPLE FINISH SPEC CHOICES RES-11 RESILIENT FLOORINGFINESS FLOOR (STRENGTH AND FUNCTIONAL)ECORE COMMERCIAL FLOORINGMOTIVATEES505CHARCOAL 48"X25LFX7.5MM DRY-LAY INSTALLATION FINISH SPEC CHOICES RES-10 RESILIENT FLOORINGFITNESS FLOOR (CARDIO)ECORE COMMERCIAL FLOORINGSTRAIT RX6624SEA GRASS 72"X30LFX7MM DRY-LAY INSTALLATION FINISH SPEC CHOICES RES-01 RESILIENT FLOORINGGUEST SUITE FLOORTARKETTHOMEWOOD SUITES CUSTOMX-6641 7"X48"CLICK-IN, ASHLAR FINISH SPEC CHOICES RB-11 VINYL BASEFITNESS BASETARKETTMONUMENTMW-48-S448- GREY 4" HIGH 45 DEG MITER ON CORNERS FINISH SPEC CHOICES RB-10 VINYL BASEGUEST CORRIDOR, MEETING ROOM, CENTRAL HUB BASETARKETTMONUMENTMW-24-S424- GREY HAZE 4" HIGH 45 DEG MITER ON CORNERS FINISH SPEC CHOICES RB-01 VINYL BASEGUEST SUITE BASETARKETTMONUMENTMW-27-S427- MIST 4" HIGH 45 DEG MITER ON CORNERS FINISH SPEC CHOICES QT-10.1 QUARRY TILE BASEFOOD PREP FLOORDAL-TILEQUARRY QUE-TREAD SERIESOQ94- BEIGE- PAVER 6"X6"X1/2"STACKED BOND VERIFY COLOR WITH ARCHITECT GROUT GR-07 FINISH SPEC CHOICES QT-10 QUARRY TILEFOOD PREP FLOORDAL-TILEQUARRY QUE-TREAD SERIESOQ94- BEIGE- PAVER 6"X6"X1/2"STACKED BOND VERIFY COLOR WITH ARCHITECT GROUT GR-07 FINISH SPEC CHOICES PT-E EXTERIOR PAINTFIBER CEMET SOFFITS, FASCIAS, EXTERIOR ELEMENTSSHERWIN-WILLIAMSTYPE TO MATCH SUBSTRATESW7510CHATEAU BROWN (242-C7)EGGSHELL MIN 1 COAT PRIMER, 2 COATS PAINT FINISH SPEC CHOICES PT-D EXTERIOR PAINTFIBER CEMET SOFFITS, FASCIAS, EXTERIOR ELEMENTSSHERWIN-WILLIAMSTYPE TO MATCH SUBSTRATESW6118LEATHER BOUND (291-C7)EGGSHELL MIN 1 COAT PRIMER, 2 COATS PAINT FINISH SPEC CHOICES PT-C EXTERIOR PAINTFIBER CEMET SOFFITS, FASCIAS, EXTERIOR ELEMENTSSHERWIN-WILLIAMSTYPE TO MATCH SUBSTRATESW7525TREE BRANCH (288-C7)EGGSHELL MIN 1 COAT PRIMER, 2 COATS PAINT FINISH SPEC CHOICES PT-B EXTERIOR PAINTFIBER CEMET SOFFITS, FASCIAS, EXTERIOR ELEMENTSSHERWIN-WILLIAMSTYPE TO MATCH SUBSTRATESW7153SANDERLING (248-C5)EGGSHELL MIN 1 COAT PRIMER, 2 COATS PAINT FINISH SPEC CHOICES PT-A EXTERIOR PAINTFIBER CEMET SOFFITS, FASCIAS, EXTERIOR ELEMENTSSHERWIN-WILLIAMSTYPE TO MATCH SUBSTRATESW6154NACRE (263-C2)EGGSHELL MIN 1 COAT PRIMER, 2 COATS PAINT FINISH SPEC CHOICES PT-15 PAINTCENTRAL HUB BASE, HOLD OPEN DOORSSHERWIN-WILLIAMSPRO-MAR 200 ZERO VOC SEMI-GLOSS SW7029AGREEABLE GRAY SEMI-GLOSS MIN 1 COAT PRIMER, 2 COATS PAINT FINISH SPEC CHOICES PT-14 PAINTFITNESS EXTERIOR WALLSHERWIN-WILLIAMSPRO-MAR 200 ZERO VOC LOW GLOSS SW7655STAMPED CONCRETE EGGSHELL MIN 1 COAT PRIMER, 2 COATS PAINT FINISH SPEC CHOICES PT-13 PAINTGUEST LAUNDRY EXTERIOR WALLSHERWIN-WILLIAMSPRO-MAR 200 ZERO VOC LOW GLOSS SW9132ACACIA HAZE EGGSHELL MIN 1 COAT PRIMER, 2 COATS PAINT FINISH SPEC CHOICES PT-12 PAINTCENTRAL HUB EXTERIOR WALLSHERWIN-WILLIAMSPRO-MAR 200 ZERO VOC LOW GLOSS SW7029AGREEABLE GRAY EGGSHELL MIN 1 COAT PRIMER, 2 COATS PAINT FINISH SPEC CHOICES PT-11 PAINTGUEST CORRIDOR SERVICE DOORS, ACCESS PANELS, TRIMSHERWIN-WILLIAMSPRO-MAR 200 ZERO VOC SEMI-GLOSS SW7030ANEW GRAY SEMI-GLOSS MIN 1 COAT PRIMER, 2 COATS PAINT FINISH SPEC CHOICES PT-10 PAINTGUEST CORRIDOR EXTERIOR WALLSHERWIN-WILLIAMSPRO-MAR 200 ZERO VOC LOW GLOSS SW7030ANEW GRAY EGGSHELL MIN 1 COAT PRIMER, 2 COATS PAINT FINISH SPEC CHOICES PT-05 PAINTPOWDER COAT FINISHSHERWIN-WILLIAMSPRO-MAR 200 ZERO VOCMATCH PC-05 VERIFY WITH ARCHITECT MIN 1 COAT PRIMER, 2 COATS PAINT FINISH SPEC CHOICES PT-04 PAINTDOORS, WINDOWS, STOREFRONT, METALWORKSHERWIN-WILLIAMSPRO-MAR 200 ZERO VOCMATCH PC-04 VERIFY WITH ARCHITECT MIN 1 COAT PRIMER, 2 COATS PAINT FINISH SPEC CHOICES PT-03 PAINTGUEST SUITE TRIM, VALENCE, INTERIOR DOORS, BACK OF HOUSESHERWIN-WILLIAMSPRO-MAR 200 ZERO VOC SEMI-GLOSS SW7042SHOJI WHITE SEMI-GLOSS MIN 1 COAT PRIMER, 2 COATS PAINT FINISH SPEC CHOICES PT-01 PAINTCEILINGS THROUGOUTSHERWIN-WILLIAMSPRO-MAR 200 ZERO VOCSW7005PURE WHITE FLAT MIN 1 COAT PRIMER, 2 COATS PAINT FINISH SPEC CHOICES PL-06 PLASTIC LAMINATEBLACKWILSONARTPLASTIC LAMINATE1595-38BLACK FINE VELVET FINISH WITH AEON FINISH SPEC CHOICES PL-05 PLASTIC LAMINATETEXTUREWILSONARTPLASTIC LAMINATE4943-38CLASSIC LINEN FINE VELVET FINISH WITH AEON FINISH SPEC CHOICES PL-04 PLASTIC LAMINATEDARK WOODWILSONARTPLASTIC LAMINATE7991K-12NEO WALNUT SOFT GRAIN FINISH WITH AEON FINISH SPEC CHOICES PL-03 PLASTIC LAMINATELIGHT TEXTUREWILSONARTPLASTIC LAMINATE4877K-19GREY MESH LENO WEAVE FINISH WITH AEON FINISH SPEC CHOICES PL-01 PLASTIC LAMINATELIGHT WOODWILSONARTPLASTIC LAMINATE7967K-12PARK ELM SOFT GRAIN FINISH WITH AEON FINISH SPEC CHOICES PF-15 PRE-FINISHED DOORSINTERIOR DOORS-MATCH PT-15 FINISH SPEC CHOICES PF-11 PRE-FINISHED DOORSINTERIOR DOORS-MATCH PT-11 FINISH SPEC CHOICES PF-11 FIBER REINFORCED POLYMER POOL DOORS-FRP PRE-FINISHED DOORS-MATCH PT-11 FINISH SPEC CHOICES PF-03 PRE-FINISHED DOORSINTERIOR DOORS-MATCH PT-03 FINISH SPEC CHOICES PC-E POWDER COATDOORS, LOUVERS, METAL ELEMENTS, EXTERIOR PENETRATIONS-MATCH PT-E EXTERIOR FINISH LEGEND PC-D POWDER COATDOORS, LOUVERS, METAL ELEMENTS, EXTERIOR PENETRATIONS-MATCH PT-D EXTERIOR FINISH LEGEND PC-C POWDER COATDOORS, LOUVERS, METAL ELEMENTS, EXTERIOR PENETRATIONS-MATCH PT-C EXTERIOR FINISH LEGEND PC-B POWDER COATDOORS, LOUVERS, METAL ELEMENTS, EXTERIOR PENETRATIONS-MATCH PT-B EXTERIOR FINISH LEGEND PC-A POWDER COATDOORS, LOUVERS, METAL ELEMENTS, EXTERIOR PENETRATIONS-MATCH PT-A EXTERIOR FINISH LEGEND PC-11 POWDER COATDOORS, LOUVERS, METAL ELEMENTS, EXTERIOR PENETRATIONS-MATCH PT-11 FINISH SPEC CHOICES PC-05 POWDER COATDOORS, LOUVERS, METAL ELEMENTS, EXTERIOR PENETRATIONSTIGER DRYLAC USA, INCSTELLIX BONDED METALLIC49/61120LOW LIGHTS BRONZE FINISH SPEC CHOICES PC-04 POWDER COATDOORS, LOUVERS, METAL ELEMENTS, EXTERIOR PENETRATIONSTIGER DRYLAC USA, INCSTELLIX BONDED METALLIC49/92880APRX TO RAL 9007- SILVER GLOSS FINISH SPEC CHOICES PC-03 POWDER COATDOORS, LOUVERS, METAL ELEMENTS, EXTERIOR PENETRATIONS-MATCH PT-03 FINISH SPEC CHOICES GT-06 GROUTKITCHEN FLOOR AND BASEPER CONTRACTORFINE-TEXTURED FINISHVERIFY WITH ARCHITECT 3/8" (REC)HIGH PERFORMANCE OR EPOXY INCLUDE CLEAR MATTE SEALER QT-10 FINISH SPEC CHOICES GT-05 GROUTKITCHEN FLOOR AND BASEPER CONTRACTORFINE-TEXTURED FINISHVERIFY WITH ARCHITECT 3/8" (REC)HIGH PERFORMANCE OR EPOXY INCLUDE CLEAR MATTE SEALER QT-9 FINISH SPEC CHOICES GT-04 GROUTKITCHEN FLOOR AND BASEPER CONTRACTORFINE-TEXTURED FINISHVERIFY WITH ARCHITECT 3/8" (REC)HIGH PERFORMANCE OR EPOXY INCLUDE CLEAR MATTE SEALER QT-8 FINISH SPEC CHOICES GT-03 GROUTKITCHEN FLOOR AND BASEPER CONTRACTORFINE-TEXTURED FINISHVERIFY WITH ARCHITECT 3/8" (REC)HIGH PERFORMANCE OR EPOXY INCLUDE CLEAR MATTE SEALER QT-7 FINISH SPEC CHOICES GT-03 GROUTWALL TILELATICRETE INTERNATIONAL90- LIGHT PEWTER 1/8" (REC)HIGH PERFORMANCE OR EPOXY INCLUDE CLEAR MATTE SEALER CT-12 FINISH SPEC CHOICES GT-02 GROUTWALL TILECUSTOM BUILDING PRODUCTS381- BRIGHT WHITE 1/8" (REC)HIGH PERFORMANCE OR EPOXY INCLUDE CLEAR MATTE SEALER CT-11 FINISH SPEC CHOICES GT-01 GROUTFLOOR TILE AND BASELATICRETE INTERNATIONAL90- LIGHT PEWTER 3/16" (REC)HIGH PERFORMANCE OR EPOXY INCLUDE CLEAR MATTE SEALER CT-01, CT-10 FINISH SPEC CHOICES FRP-01 FIBER REINFORCED POLYMER KITCHEN WALLSMARLITEPEBBLED FRPP100- WHITE (CLASS A)4' WIDE PANELS TRIM AND SEAL PER MANUFACTURER SILICONE SEALANT- MS 251 MARLITE TRIM PVC MOLDING FINISH SPEC CHOICES CT-19 CERAMIC TILEPOOL COPINGDAL-TILENOMINEENM10XTP1224C6MT NM10- SAND- MATTE 12"X24"X6CM RETURN -GROUT GT-06 FINISH SPEC CHOICES CT-18 CERAMIC TILEPOOL DESIGNATION TILES (DEPTH/NO DIVING)DAL-TILENOMINEENM10XTP1224C6MT NM10- SAND- MATTE 12"X24"X6CM RETURN VERIFY W/ REP MAKE IT YOUR OWN- CUSTOM GROUT GT-06 FINISH SPEC CHOICES CT-17 CERAMIC TILEPOOL WATERLINEDAL-TILECOLOR WHEEL LINEAR GLAZED1049- OCEAN BLUE- CLOSSY 4"X4"X5/16"1/3 OFFSET GUNNITE FINISH SPEC CHOICES CT-16 CERAMIC TILEPOOL WALL ACCENTDAL-TILECOLOR WHEEL LINEAR GLAZED1049- OCEAN BLUE- GLOSSY 3"X6"X5/16"1/3 OFFSET GROUT GT-06 FINISH SPEC CHOICES CT-15 CERAMIC TILEPOOL AND POOL BATHROOM WALLSDAL-TILEVOLUME 1.0VL71- DEGREES SILVER- MATTE 12"X24"X5/16"1/3 OFFSET GROUT GT-06 FINISH SPEC CHOICES CT-14 CERAMIC TILEOUTDOOR KITCHENDAL-TILED-SEGNI- GLAZED PORCEKAIN BIRDSEYESAND BLEND MOUJ- MATTE 8"X8"X3/8"-GROUT GT-05 FINISH SPEC CHOICES CT-13 CERAMIC TILESUITE SHOP WALL ACCENTDAL-TILECOLOR WHEEL LINEAR GLAZED0190- ARCTIC WHITE- GLOSSY 4"X12"X5/16"STACKED BOND GROUT GT-04 FINISH SPEC CHOICES CT-12 CERAMIC TILECENTRAL HUB TAP WALL ACCENTDAL-TILECRAFTER- HEXAGON PAPERBLOCK CF20- MATTE 8"X9"X5/16"-GROUT GT-03 FINISH SPEC CHOICES CT-11 CERAMIC TILEPUBLIC RESTROOM WALLSDAL-TILEMY CITY- SHANGHAITEMPLE LIMESTONE- MATTE SH30 12"X24"X5/16"STACKED BOND GROUT GT-02 FINISH SPEC CHOICES CT-10.1 CERAMIC TILE BASEPUBLIC SPACE FLOOR BASEDAL-TILEVOLUME 1.0VL71- DEGREES SILVER- MATTE 4"X24"X5/16"1/3 OFFSET GROUT GT-01 FINISH SPEC CHOICES CT-10 CERAMIC TILEPUBLIC SPACE FLOORDAL-TILEVOLUME 1.0VL71- DEGREES SILVER- MATTE 12"X24"X5/16"1/3 OFFSET GROUT GT-01 (GT-06 @ POOL) FINISH SPEC CHOICES CT-01.1 CERAMIC TILE BASEGUEST BATHROOM FLOOR BASEDAL-TILEVOLUME 1.0VL71- DEGREES SILVER- MATTE 4"X24"X5/16"1/3 OFFSET GROUT GT-01 FINISH SPEC CHOICES CT-01 CERAMIC TILEGUEST BATHROOM FLOORDAL-TILEVOLUME 1.0VL71- DEGREES SILVER- MATTE 12"X24"X5/16"1/3 OFFSET GROUT GT-01 FINISH SPEC CHOICES CS-01 SEALED CONCRETE TOPPER INTERIOR FLOORS AT BOH SPACES CPT-14 CARPET TILEBACK OF HOUSETARKETTSUBSTANCE11449PURE PARCHMENT 18"X36"VERTICAL ASHLAR FLEX-AIRE MODULAR CUSHION TRANSITION STRIP TS-02, TS-03 FINISH SPEC CHOICES CPT-13 CARPET TILEMEETING ROOMTARKETTHOMEWOOD SUITES CUSTOMHS63TC.185 24"X24"VERTICAL ASHLAR FLEX-AIRE MODULAR CUSHION TRANSITION STRIP TS-02 FINISH SPEC CHOICES CPT-12 CARPET TILECENTRAL HUB INSET (CENTER AREA)TARKETTHOMEWOOD SUITES CUSTOMHS57T527 18"X36"VERTICAL ASHLAR FLEX-AIRE MODULAR CUSHION TRANSITION STRIP TS-02 FINISH SPEC CHOICES CPT-11 CARPET TILECENTRAL HUB INSET (SOCIAL NOOK AND LIVING ROOM AREA)TARKETTHOMEWOOD SUITES CUSTOMHL49T430 18"X36"ASHLAR FLEX-AIRE MODULAR CUSHION TRANSITION STRIP TS-02 FINISH SPEC CHOICES CPT-10 CARPET TILEGUEST AND PUBLIC CORRIDORSTARKETTHOMEWOOD SUITES CUSTOMHS43T243 18"X36"ASHLAR FLEX-AIRE MODULAR CUSHION TRANSITION STRIP TS-02 FINISH SPEC CHOICES CPT-02 CARPET TILEGUEST INSERT LIVING ROOMTARKETTHOMEWOOD SUITES CUSTOMHS23T230 18"X36"VERTICAL ASHLAR FLEX-AIRE MODULAR CUSHION TRANSITION STRIP TS-01 FINISH SPEC CHOICES CPT-01 CARPET TILEGUEST BEDROOMTARKETTHOMEWOOD SUITES CUSTOMHS51T130 18"X36"HERRINGBONE FLEX-AIRE MODULAR CUSHION TRANSITION STRIP TS-01 FINISH SPEC CHOICES CG-15 CORNER GUARDPUBLIC RESTROOMINPROTAPE-ON CORNER GUARD103- WHITE SAND WC-15 FINISH SPEC CHOICES CG-14 CORNER GUARDGUEST LAUNDRYINPROTAPE-ON CORNER GUARD283- STERLING WC-14 FINISH SPEC CHOICES CG-13 CORNER GUARDFITNESSINPROTAPE-ON CORNER GUARD256- CASTLE WC-13 FINISH SPEC CHOICES CG-12 CORNER GUARDCENTRAL HUBINPROTAPE-ON CORNER GUARD113- TAUPE WC-12 FINISH SPEC CHOICES CG-11 CORNER GUARDGUEST CORRIDOR DOOR DROP, CENTRAL HUB ACCENT, MEETING ROOM ACCENT INPROTAPE-ON CORNER GUARD186- MERLOT WC-11 FINISH SPEC CHOICES CG-10 CORNER GUARDGUEST CORRIDOR AND MEETING ROOM MAININPROTAPE-ON CORNER GUARD119- PEPPERMINT WC-10 FINISH SPEC CHOICES CG-02 CORNER GUARDGUEST SUITE BATHROOM (TOILET AREA)INPROTAPE-ON CORNER GUARD125- ENGLISH GREEN WC-02 FINISH SPEC CHOICES CG-01 CORNER GUARDGUEST SUITE, BATHROOM (DRESSING AREA)INPROTAPE-ON CORNER GUARD154- CLAM SHELL WC-01 FINISH SPEC CHOICES ACT-03 ACOUSTIC CEILING TILE (CL-A2) FOOD PREP CEILINGARMSTRONGOPTIMA HEALTH3114PB-WHWHITE 24"X24"ALUMINUM, CLEAN ROOM 1-1/2" SQUARE LAY-IN 15/16 SPECIFICATION BOOK ACT-02 ACOUSTIC CEILING TILE (CL-A1) SUITE SHOP CEILINGARMSTRONGLYRA CONCEALED-CHARCOAL GREY (MED-DARK GREY) 24"X24"BEVELED, CONCEALED 15/16"CONCEALED, QUICK KERF SPECIFICATION BOOK ACT-01 ACOUSTIC CEILING TILE (CL-A) CORRIDOR, LOBBY, BOH CEILINGSARMSTRONGLYRA OR OPTIMA CONCEALED-WHITE 24"X24"BEVELED, CONCEALED 15/16"CONCEALED, QUICK KERF SPECIFICATION BOOK BRANDPRODUCT NAMEPRODUCT IDCOLOR SIZE ADDITIONAL INFO NOTES ASSOCIATED ELEMENT TAG TYPELOCATION/DESCRIPTION PRODUCT INFORMATION LOCATION OF INFORMATION FINISH SCHEDULE 7 H A-701 2 TAP WALL SELF-BUSSING AND TRASH CHILLED COUNTER 0' - 6"2' - 0"0' - 3" 4' - 2 1/4" 3/4" ENGINEERED STONE ON PLYWOOD SUBSTRATE 0' - 3" 1 A-702 2 A-702 LINE OF SHELF ABOVE A-701 3 LINE OF SHELF ABOVE 6' - 0"0' - 2 1/2"3' - 6 1/2"0' - 3"10 EQ. PANELS 17' - 2 1/2" 3/4" ENGINEERED STONE ON PLYWOOD SUBSTRATE PL-01, TYP. LAMINATE OVER PLYWOOD SUBSTRATE LAMINATE OVER PLYWOOD SUBSTRATE CABINET DOOR PANELS 0' - 3"0' - 3"0' - 4"4' - 2 1/4" 2' - 6" 2' - 6"2' - 5 1/2"0' - 5"0' - 6 1/4"0' - 1 3/4"3' - 7"3' - 6"4' - 0"4' - 9"10' - 0"PL-01PL-01 PL-01 CT-12 PL-03 K-55 K-55.1 K-56 4 A-701 2' - 0"4 A-701 0' - 7 1/4"0' - 9"2' - 6" FLIP-DOWN HINGED DOOR WITH MAGNETIC CATCH 2' - 0" 1' - 11 3/4" 0' - 7 1/4"0' - 9" 0' - 6 3/4"6 1/4"5"2' - 5"0' - 0 1/2"3' - 7"BUSSING TUB BY OTHERS TRASH RECEPTACLE BY OTHERS CABINET DOOR 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216MILLWORK DETAILS-LOBBY TAP WALL A-701 FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 1" = 1'-0" Reference: 1 / A-431 1TAP WALL AND BREAKFAST BAR PLAN East Wall in Lobby- Tap Wall and Breakfast Bar (Room 121) 1" = 1'-0" Reference: 2 / A-432 2TAP WALL AND BREAKFAST BAR ELEVATION East Wall in Lobby- Tap Wall and Breakfast Bar (Room 121) 1" = 1'-0" Reference: 1 / A-431 3 SELF BUSSING AND TRASH PLAN North Wall and Tap Wall in Lobby (Room 121) 1" = 1'-0" Reference: 2 / A-701 4 SELF-BUSSING AND TRASH SECTION North Wall and Tap Wall in Lobby (Room 121) 0'6" 1'2' SCALE: 1" = 1'-0" EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV Revision Schedule Number Description Date 8 LOCKERS 5' - 0"A-702 4 5 A-702 2' - 3 1/4"2' - 8 3/4"2' - 6 1/4"2' - 6 1/4"2' - 6 1/4"2' - 6 1/4"2' - 6 1/4"7' - 11 1/2"LAMINATE ON PLYWOOD SUBSTRATE ON ALL EXPOSED SURFACES COORDINATE WITH FABRICATOR AND DOOR HARWARE SUPPLIER TO PROVIDE LOCKER HARDWARE PER BRAND STANDARDS 2' - 8 1/2" 0' - 3"0' - 4"7' - 5"0' - 2 1/2"7' - 11 1/2"1/2"3"3' - 6 1/2"2 1/2"1 1/2"2' - 10"2' - 4 1/4"4"2' - 0 1/2" LAMINATE OVER 3/4" PLYWOOD SUBSTRATE LAMINATE SURROUND BEYOND TV AND MOUNT BY OTHERS 2 CM ENGINEERED STONE ON 3/4" PLYWOOD SUBSTRATE LAMINATE OVER 3/4" PLYWOOD SUBSTRATE 2 CM ENGINEERED STONE ON 3/4" PLYWOOD SUBSTRATE TAPS AND WALL BEYOND 2 CM ENGINEERED STONE ON 3/4" MDF SUBSTRATE UNDER-COUNTER COOLER LOCKABLE LAMINATE CABINET DOOR PANEL LAMINATE OVER PLYWOOD SUBSTRATE  3"3' - 2"1' - 2 1/2"  3"4"2' - 3"0' - 3"2' - 10"0' - 10"3"1/2"LAMINATE OVER 3/4" PLYWOOD SUBSTRATE LAMINATE SURROUND BEYOND LINEAR LED TILE BACKSPLASH LAMINATE SURROUND BEYOND TAP DISPLAY SCREEN 2 CM ENGINEERED STONE ON 3/4" PLYWOOD SUBSTRATE RECESSED STAINLESS STEEL DRIP TRAY - CONNECT TO FLOOR DRAIN COORDINATE CUTOUTS IN MILLWORK FOR CONNECTIVITY LOCKABLE LAMINATE CABINET DOOR PANEL LAMINATE OVER PLYWOOD SUBSTRATE FLOOR DRAIN3' - 2"3' - 9"737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216MILLWORK DETAILS-LOBBY AND GUESTSTORAGE A-702 FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 1" = 1'-0" Reference: 1 / A-431 3GUEST STORAGE PLAN Room 118 1" = 1'-0" Reference: 3 / A-702 4 GUEST STORAGE ELEVATION Room 118 1" = 1'-0" Reference: 9 / A-433 5 GUEST STORAGE SECTION Room 118 1" = 1'-0" Reference: 1 / A-701 1BREAKFAST BAR SECTION East Wall in Lobby- Tap Wall and Breakfast Bar (Room 121) 1" = 1'-0" Reference: 1 / A-701 2TAP WALL SECTION East Wall in Lobby- Tap Wall and Breakfast Bar (Room 121) 0'6" 1'2' SCALE: 1" = 1'-0" EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV Revision Schedule Number Description Date 8 HA-703 2 3 A-703 4 A-703 Typ1' - 10"2' - 0"0' - 3 1/4"5' - 6" 1' - 8"3' - 7 1/4" 0' - 2 3/4"1' - 5 3/4"0' - 2"0' - 3 1/4" SS-01: 2 CM ENGINEERED STONE ON 3/4" PLYWOOD SUBSTRATE REMOVABLE BUSSING TUB, BY OTHERS WALL COVERING SS-01: 2 CM ENGINEERED STONE BACKSPLASH ø 0' - 10"0' - 7"0' - 5"0' - 10"0' - 5"0' - 4"2' - 4 1/2"0' - 1 1/2"3' - 3 1/2"0' - 2 1/2"0' - 4"SS-01: 2 CM ENGINEERED STONE ON 3/4" PLYWOOD SUBSTRATE SS-01: 2 CM ENGINEERED STONE BACKSPLASH ON 3/4" PLYWOOD SUBSTRATE WALL COVERING LAMINATE ON PLYWOOD SUBSTRATE CONTINUOUS RECESSED LIGHTING WITH CONCEALMENT ANGLE WALL COVERING PLASTIC LAMINATE PANEL BEYOND LAMINATE ON PLYWOOD SUBSTRATE BLOCKING BEHIND GYP. WALL CONTINUOUS CONCEALED LED TAPE LIGHT WITH DIFFUSER PLASTIC LAMINATE PANEL BEYOND WALL COVERING 2 CM ENGINEERED STONE ON 3/4" PLYWOOD SUBSTRATE 2 CM ENGINEERED STONE BACKSPLASH REMOVABLE BUSSING TUB 0' - 4"2' - 4 1/2"0' - 1 1/2"0' - 6"0' - 4"3' - 3 1/2"0' - 2 1/2"1' - 6 1/2"VERIFY ACTUAL0' - 3"0' - 0 1/2"2' - 0 3/4" LAMINATE ON PLYWOOD SUBSTRATE OPERABLE CABINET DOOR; PROVIDE TOUCH LATCH HARDWARE CONTINUOUS RECESSED LIGHTING WITH CONCEALMENT ANGLE WALL COVERING PLASTIC LAMINATE PANEL BEYOND LAMINATE ON PLYWOOD SUBSTRATE BLOCKING BEHIND GYP. WALL CONTINUOUS CONCEALED LED TAPE LIGHT WITH DIFFUSER PLASTIC LAMINATE PANEL BEYOND WALL COVERING 2 CM ENGINEERED STONE ON 3/4" PLYWOOD SUBSTRATE W/ MATCHING BACKSPLASH STAINLESS STEEL LAMINATE COLLAR 0' - 4"2' - 4 1/2"0' - 1 1/2"0' - 4"3' - 3 1/2"0' - 2 1/2"1' - 6 1/2"VERIFY ACTUAL0' - 3"0' - 0 1/2"2' - 0 3/4" 0' - 10" TRASH LAMINATE ON PLYWOOD SUBSTRATE OPERABLE CABINET DOOR; PROVIDE TOUCH LATCH HARDWARE TOE KICK ATTACHED TO DOOR 7 A-703 6 2' - 10 3/4"5' - 0" 2' - 10 3/4"2' - 1"R 0' - 5"R 0' - 5"1' - 0"1' - 0"1' - 0"WATER STATION 7 A-703 Typ8 A-703 9 A-703 SHAFT 2 CM ENGINEERED STONE ON 3/4" PLYWOOD SUBSTRATE 0' - 4"4' - 2"2 CM ENGINEERED STONE ON 3/4" PLYWOOD SUBSTRATE 2 CM ENGINEERED STONE BACKSPLASH WATER STATION TOWEL SHELF TOWEL SHELF TRASH/TOWEL BINTRASH/TOWEL BIN 2' - 2" 0' - 3" 1/2"4"2' - 5 1/4"2' - 10"7' - 2"4' - 1 1/2"2"1/2"LAMINATE BEYOND WALL COVERING AT BACK WALL 2 CM ENGINEERED STONE ON 3/4" PLYWOOD SUBSTRATE0' - 4"LAMINATE ON PLYWOOD SUBSTRATE ON ALL EXPOSED SURFACES LOCKABLE LAMINATE CABINET DOOR PANEL 0' - 7"0' - 10" 0' - 7" 2' - 0" TRASH/TOWEL BIN 2' - 2" 2' - 0" 0' - 3" 1/2"0' - 4"2' - 5 1/4"2' - 10"7' - 2"4' - 1 1/2"2"1/2"EQEQLAMINATE BEYOND WALL COVERING AT BACK WALL SS-01: 2 CM ENGINEERED STONE ON 3/4" PLYWOOD SUBSTRATE LAMINATE ON PLYWOOD SUBSTRATE ON ALL EXPOSED SURFACES0' - 4"TOWEL SHELF TOWEL SHELF 2' - 3"WALLCOVERING ON GYP WALL RECESSED BOTTLE FILLING STATION BASE AS SCHEDULED 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216MILLWORK DETAILS-FITNESS AND LOBBY A-703 FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 1" = 1'-0" Reference: 1 / A-431 1TRASH AND BUSSING PLAN In Public Corridor East of Lobby 1" = 1'-0" Reference: 1 / A-703 2TRASH AND BUSSING ELEVATION In Public Corridor East of Lobby 1" = 1'-0" Reference: 1 / A-703 3 TRASH AND BUSSING SECTION @ BINS In Public Corridor East of Lobby 1" = 1'-0" Reference: 1 / A-703 4 TRASH AND BUSSING SECTION @ TRASH In Public Corridor East of Lobby 1" = 1'-0" Reference: 9 / A-435 5FITNESS NICHE PLAN Room 114 1" = 1'-0" Reference: 5 / A-703 6FITNESS NICHE ELEVATION Room 114 1" = 1'-0" Reference: 6 / A-435 7FITNESS NICHE AT TOWEL/TRASH BIN Room 114 1" = 1'-0" Reference: 6 / A-435 8 FITNESS NICHE AT TOWEL SHELVES Room 114 1" = 1'-0" Reference: 6 / A-435 9 FITNESS WATER STATION SECTION Room 114 0'6" 1'2' SCALE: 1" = 1'-0" EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV Revision Schedule Number Description Date 6 A-704 6 A-704 9 A-704 9 A-704 FF&E VANITY MIRROR 2 CM BACKSPLASH FINISH TO MATCH COUNTERTOP 2 CM ENGINEERED STONE COUNTERTOP SURFACE, STRAIGHT PROFILE WITH EASED EDGE 1/4" REVEAL LAMINATE OVER 3/4" PLYWOOD PROVIDE ADDITIONAL SUPPORT FOR COUNTER BEHIND DRYWALL 2' - 0" INTERNAL BRACING FOR COUNTER RE DETAIL ????0' - 4"8" MIN 1/2"9" MIN2' - 3" MIN4 3/4"2"2' - 10" MAX3' - 4" MAX TO BOTTOM OF REFLECTIVE SURFACE0' - 4"2"2' - 3" MIN2' - 10" MIN0' - 9" MIN8" MIN 1/2" 2' - 0" FF&E ARTWORK 2 CM BACKSPLASH FINISH TO MATCH COUNTERTOP 2 CM ENGINEERED STONE COUNTERTOP SURFACE, STRAIGHT PROFILE WITH EASED EDGE INTERNAL BRACING FOR COUNTER RE DETAIL ???? 1/4" REVEAL CUSTOM GRADE CABINET MILLWORK PROVIDE ADDITIONAL SUPPORT FOR COUNTER BEHIND DRYWALL0' - 11" MIN4 3/4"7' - 1"0' - 6" 2' - 10" 0' - 3" BACK LIT METAL SIGNAGE ON STANDOFFS LAMINATE ON 3/4" PLYWOOD SUBSTRATE PAINT LAMINATE PANEL GRAB AND GO AFF 11'-4" AFF 10'-2"2 1/2"3' - 7 1/2"1' - 0 1/2"2 1/2"1' - 0 1/2"2 1/2"6' - 4"1' - 3" WALL COVERING LAMINATE ON PLYWOOD SUBSTRATE BLOCKING BEHIND GYP. WALL FFE PRINTER CASEGOOD AS SCHEDULED PAINTED WOOD BASE 6' - 10 1/2" GRAB AND GOFREEZER 2' - 10"0' - 10 1/2"(2'-5")RE EQUIPMENT REQUIREMENTS2"(4'-11/2") RE EQUIPMENT REQUIREMENTS 2' - 0 1/4" LAMINATE SEAM MITERED CORNER LAMINATE OVER PLYWOOD, TYP. 1" = 1'-0"8PUBLIC RESTROOM SECTION @ VANITY Rooms 116 & 118 1" = 1'-0"10PUBLIC RESTROOM SECTION @ CHANGING Rooms 116 & 118 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216MILLWORK DETAILS-LOBBY AND PUBLIC A-704 FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 0'6" 1'2' SCALE: 1" = 1'-0" 1" = 1'-0" Reference: 8 / A-432 1LOBBY WATER ELEVATION South Wall in Lobby (Room 121) 1" = 1'-0" Reference: 1 / A-431 2LOBBY WATER PLAN South Wall in Lobby (Room 121) 1" = 1'-0" Reference: 1 / A-431 3ICE/WATER PLAN Room 118A 1" = 1'-0" Reference: 11 / A-433 4ICE/WATER ELEVATION Room 118A 1" = 1'-0" Reference: 5 / A-432 5 GRAB AND GO NICHE SECTION East Wall in Lobby- Suite Shop (Room 121) 1" = 1'-0" Reference: 1 / A-704 6LOBBY WATER SECTION South Wall in Lobby (Room 121) 1" = 1'-0" Reference: 5 / A-432 7 LIVING ROOM SECTION East Wall in Lobby- Suite Shop (Room 121) 1" = 1'-0"9ICE/WATER SECTION 1" = 1'-0" Reference: 1 / A-431 11 GRAB AND GO PLAN East Wall in Lobby- Suite Shop (Room 121) 1" = 1'-0"12 CENTRAL HUB CHECK IN COOLER PLAN EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV Revision Schedule Number Description Date 5 2' - 1"1' - 4 1/2"2' - 5 1/2"4' - 3" A-705 1 R 0' - 5 "1' - 1 3/4"MICROWAVE 4 A-705 5 A-705 6 A-705 MICROWAVE1' - 0 1/2"1' - 3"1' - 5 1/2"2' - 10"6' - 7"5' - 0" 3' - 0"PLASTIC LAMINATE ON 3/4" PLYWOOD SUBSTRATE FLOATING LAMINATE SHELF DISHWASHER PROVIDE MILLWORK PANEL COMPLIANT WITH ADA TO SCREEN GARBAGE DISPOSAL, PLUMBING & SINK(LAMINATE OVER 3/4" PLYWOOD SUBSTRATE) 11" MIN 9" MIN2' - 1"2' - 3" MIN0' - 5 1/2"2' - 10" MAX6' - 7"8" MIN  4" TILE BACKSPLASH PLASTIC LAMINATE ON 3/4" PLYWOOD SUBSTRATE PROVIDE MILLWORK PANEL COMPLIANT WITH ADA TO SCREEN GARBAGE DISPOSAL, PLUMBING & SINK(LAMINATE OVER 3/4" PLYWOOD SUBSTRATE) FINISHED SIDE OF BASE CABINET BEYOND BASE AS SCHEDULE 0' - 10" 3"2' - 6"2' - 10"2' - 10"6' - 7"LAMINATE OVER 3/4" PLYWOOD SUBSTRATE (ALL EXPOSED EDGES) BLOCKING BEHIND GYP. WALL TILE BACKSPLASH PLASTIC LAMINATE ON 3/4" MDF SUBSTRATE MICROWAVE DISHWASHER 2' - 1" 3/4"  3" 4"2' - 5 1/4"3/4"2' - 10"1' - 3"0' - 3"1' - 0" 0' - 3"6' - 7"0' - 10" 2' - 0 1/2" REFER TO DETAIL ??? LAMINATE OVER 3/4" PLYWOOD SUBSTRATE (ALL EXPOSED EDGES) BLOCKING BEHIND GYP. WALL TILE BACKSPLASH PLASTIC LAMINATE ON 3/4" MDF SUBSTRATE FLOATING LAMINATE SHELF STAINLESS STEEL LAMINATE COLLAR CABINET DOOR LAMINATE OVER 3/4" PLYWOOD SUBSTRATE 0' - 10" TRASH 0' - 4"0' - 2 1/2"2' - 10"3' - 0" BACKSPLASH FINISH TO MATCH COUNTERTOP LAMINATE ON PLYWOOD SUBSTRATE ON ALL EXPOSED SURFACES HIDDEN METAL CANTILEVERED SUPPORT IN WALL ∠2" X 1/2" X 3/16" HIDDEN FLAT BRACKET PAINT TO MATCH COUNTER CONTRACTOR TO ENGINEER SUPPORT LAMINATE PANEL BEYOND PAINTED METAL BASE A-705 11 0' - 4"0' - 2 1/2"3' - 6 1/2"3' - 0" LAMINATE ON PLYWOOD SUBSTRATE ON ALL EXPOSED SURFACES HIDDEN METAL CANTILEVERED SUPPORT IN WALL ∠2" X 1/2" X 3/16" HIDDEN FLAT BRACKET PAINT TO MATCH COUNTER CONTRACTOR TO ENGINEER SUPPORT LAMINATE PANEL BEYOND PAINTED METAL BASE WASHER/DRYER TOP∠1 1/2 X 1 1/2 X3/16 EDGE CONTINUOUS ∠1 1/2 X 1 1/2 X3/16 WALL∠2 1/2 X 2 1/2 X3/16 W/ 1/2" DIA BOLTS THROUGH WD BLOCKING AND STUD FRAMING BEHIND GYP BD1' - 6"1 1/2"1 1 / 2 " 1/4" 1 1/2" REF. RICHELIEU CONTEMPORARY PULL 66755 METALREF. T O EL E V A TI O N F O R C U ST O M P ULL L E N G T H REF. RICHELIEU CONTEMPORARY PULL 66755 METAL 2' - 10"4"2 5/8"FROSTED ACRYLIC LIGHTING AS SPECIFIED FURNITURE AS SPECIFIED POWER UNIT WALLCOVERING AS SCHEDULED 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216MILLWORK DETAILS-EMPLOYEE ANDLAUNDRY LOUNGE A-705 FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 1" = 1'-0" Reference: 9 / A-435 2EMPLOYEE ROOM KITCHEN PLAN Room 110 1" = 1'-0" Reference: 2 / A-705 1EMPLOYEE ROOM KITCHEN ELEVATION Room 110 1" = 1'-0" Reference: 2 / A-705 4EMPLOYEE ROOM KITCHEN SECTION @ SINK Room 110 1" = 1'-0" Reference: 2 / A-705 5EMPLOYEE ROOM KITCHEN SECTION @ DISHWASHER Room 110 1" = 1'-0" Reference: 2 / A-705 6EMPLOYEE ROOM KITCHEN SECTION @ TRASH Room 110 0'6" 1'2' SCALE: 1" = 1'-0" 1" = 1'-0" Reference: 13 / A-435 3 LAUNDRY LOUNGE FOLDING TABLE Room 112 1" = 1'-0" Reference: 13 / A-435 7 LAUNDRY LOUNGE COUNTER Room 112 1" = 1'-0" Reference: 3 / A-705 11 BRACING DETAIL 3" = 1'-0"10UPPER CABINET PULL DETAIL 3" = 1'-0"9LOWER CABINET PULL DETAIL 1" = 1'-0"8CENTRAL HUB BANQUETTE LIGHT EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV Revision Schedule Number Description Date 8 A-7062 1' - 7 1/2"1' - 1 1/2"7' - 4 1/2"1' - 1 1/2"1' - 7 1/2"9' - 7 1/2"1' - 1 1/2"0' - 10"0' - 5 3/4"5' - 1 3/4"1' - 8 3/4"0' - 8 1/2" 2' - 5 1/4"7' - 7"0' - 10 1/2"0' - 4 3/4"A-706 4 A-706 3 0' - 8 1/2"4' - 1"0' - 1"0' - 11"1' - 1 1/2"2' - 0 3/4"0' - 4 3/4"5' - 6 3/4"2' - 6" 0' - 11"1' - 1 1/2"2' - 0 3/4"0' - 7 3/4"4' - 9 1/2"0' - 1"3' - 1"0' - 8 3/4"R 1 ' - 6 " R 1' - 6"R 1' - 6"R 1 ' - 6 " 1' - 1 3/4"5' - 0"2' - 0 1/2"0' - 8 1/2" 1' - 3 1/2"0' - 10 3/4"A-7065 1 A-707 2 A-707 5 A-707 Typ 6 A-707 Typ 7 A-707 8 A-707 2 CM ENINEERED STONE COUNTER TOP 2 CM ENINEERED STONE COUNTER TOP 9 A-707 3 A-707 4 A-707 2' - 11"0' - 8"0' - 4"3' - 7"2 A-707 LAMINATE FINISH ON 3/4" PLYWOOD 2 CM ENGINEERED STONE COUNTER TOP 3 A-707 0' - 6"0' - 9 1/4" 0' - 9 1/4" 0' - 10 1/2" 0' - 8"0' - 4"3' - 7"1 A-707 OPEN SHELVES,LAMINATE FINISH ON 3/4" PLYWOOD ACRYLIC RAILING 2 CM ENGINEERED STONE COUNTER TOP 4 A-707 0' - 4"0' - 8"0' - 10 1/2"0' - 9 1/4"0' - 9 1/4"0' - 6"2' - 11"3' - 7"1 A-707 OPEN SHELVES,LAMINATE FINISH ON 3/4" PLYWOOD ACRYLIC RAILING 2 CM ENGINEERED STONE COUNTER TOP 2 CM ENGINEERED STONE COUNTER TOP LAMINATE FINISH ON 3/4" PLYWOOD 4 A-707 0' - 4"0' - 10 1/2"0' - 9 1/4"0' - 9 1/4"0' - 6"2' - 11"0' - 8"2 A-707OPEN SHELVES,LAMINATE FINISH ON 3/4" PLYWOOD 2 CM ENGINEERED STONE COUNTER TOP ACRYLIC RAILING ACRYLIC RAILING OPEN SHELVES,LAMINATE FINISH ON 3/4" PLYWOOD 0' - 8"0' - 10 1/2"0' - 9 1/4"0' - 9 1/4"0' - 6"3 A-707 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216MILLWORK DETAILS-RECEPTION DESK PLANAND OUTSIDEELEVATIONS A-706 FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 1" = 1'-0"1Reception Desk Detailed Plan 1" = 1'-0"2Front Desk Det. Front Elevation 1" = 1'-0"3 Front Desk Det. Left Side Elevation 1" = 1'-0"4 Front Desk Det. Right Side Elevation 1" = 1'-0"5Front Desk Det. Rear Elevation 0'6" 1'2' SCALE: 1" = 1'-0" EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV Revision Schedule Number Description Date 0' - 8"0' - 10 1/2"0' - 9 1/4"0' - 9 1/4"0' - 6"2' - 11"0' - 8"0' - 10 1/2"0' - 9 1/4"0' - 9 1/4"0' - 6"2' - 0 1/2"2 CM ENGINEERED STONE COUNTER TOP SPACE FOR COMPUTERSPACE FOR COMPUTER OPENOPEN SPACE FOR PRINTER LAMINATE FINISH ON 3/4" PLYWOOD LAMINATE FINISH ON 3/4" PLYWOOD2 CM ENGINEERED STONE COUNTER TOP LAMINATE FINISH ON 3/4" PLYWOOD 3' - 7"0' - 8"SPACE FOR PRINTER 0' - 4"2CM ENGINEERED STONE COUNTER 0' - 4"0' - 3"0' - 3"3' - 7"1' - 1 1/2" 1' - 6 1/2"2 1/2"METAL BASE TO BE REMOVABLE FINISH AS SPECIFIED2' - 11"LAMINATE FINISH AS SPECIFIED 1/4" REVEAL TO BE PAINTED TO MATCH LAMINATE GUEST SIDE EMPLOYEE SIDE MITERED CORNER 2CM ENGINEERED STONE COUNTER 3/4" WOOD SUBSTRATE (3) EQ DRAWERS0' - 8"POWER UNIT 0' - 4" 0' - 3"4"0' - 7 1/2"0' - 7 1/2"0' - 7 1/2"0' - 2"2' - 11"2' - 11 3/4" 2CM ENGINEERED STONE COUNTER FACE OF LAMINATE DOOR AND ENGINEERED STONE TO ALIGNCABINET DOOR TO BE LOCKABLE WITHPULL HARDWARE UNDER COUNTER LIGHTING LAMINATE OVER 3/4" PLYWOOD SUBSTRATE (ALL EXPOSED EDGES) HARDWOOD EDGE- STAINED TO MATCH LAMINATE ACRYLIC RAIL GROMMET FOR CORD MANAGEMENTCOORDINATE LOCATION WITH EQUIPMENT TOE KICK SHELF SHELF SHELF GUEST SIDE EMPLOYEE SIDE 1' - 0"ACRYLIC RAIL MITERED CORNER 0' - 4"0' - 3" 2CM ENGINEERED STONE COUNTER 0' - 4"0' - 3"0' - 3"3' - 7"1' - 1 1/2" 1' - 6 1/2"0' - 2 1/2"METAL BASE TO BE REMOVABLE FINISH AS SPECIFIED2' - 11"TRASH LAMINATE FINISH AS SPECIFIED 1/4" REVEAL TO BE PAINTED TO MATCH LAMINATE GUEST SIDE EMPLOYEE SIDE MITERED CORNER 2CM ENGINEERED STONE COUNTER 3/4" WOOD SUBSTRATE GROMMET FOR CORD MANAGEMENTCOORDINATE LOCATION WITH EQUIPMENT 0' - 4" LAMINATE OVER 3/4" PLYWOOD SUBSTRATE (ALL EXPOSED EDGES) 0' - 3"0' - 4"0' - 3"PRINTER 2CM ENGINEERED STONE COUNTER UNDER COUNTER LIGHTING ACRYLIC RAIL TOE KICK PULL OUT DRAWER LAMINATE 3/4" PLYWOOD SUBSTRATE LOCKABLE DRAWER 1"MITERED CORNER POWER UNIT 2' - 1 3/4"0' - 2 1/2"SHELF SHELF SHELF 1' - 1 1/2" 0' - 2 3/4" 1' - 7 1/2"0' - 5"0' - 7 3/4"1' - 5" GUEST SIDE EMPLOYEE SIDE 2' - 11"0' - 2"0' - 7 1/2"0' - 1 3/4"0' - 7 1/2"0' - 1 3/4"SHELF SHELF SHELF GUEST SIDE EMPLOYEE SIDE 0' - 3"4"2"0' - 1 3/4"1 3/4"2"2' - 0 1/2"10 12"0' - 6"0' - 5" 1' - 0" 1' - 5 1/2" 2CM ENGINEERED STONE COUNTER MITERED CORNER ACRYLIC RAIL UNDER COUNTER LIGHTING LAMINATE OVER 3/4" PLYWOOD SUBSTRATE (ALL EXPOSED EDGES) HARDWOOD EDGE- STAINED TO MATCH LAMINATE TOE KICK0' - 8"0' - 2 1/2"0' - 3"3"2" LAMINATE 3/4" PLYWOOD SUBSTRATE LOCKABLE SWING DOOR EQEQ2 CM ENGINEERED STONE COUNTER TOP LAMINATE FINISH ON 3/4" PLYWOOD 2' - 11"0' - 8"3' - 7"2 CM ENGINEERED STONE COUNTER TOP SPACE FOR PRINTER0' - 10 1/2"0' - 9 1/4"0' - 9 1/4"0' - 6"0' - 8"2' - 11"LAMINATE FINISH ON 3/4" PLYWOOD 2 CM ENGINEERED STONE COUNTER TOP 0' - 8"2' - 11"737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216MILLWORK DETAILS-RECEPTION DESKSECTIONS AND DETAILS A-707 FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 1" = 1'-0"1Front Desk Section -1 1" = 1'-0"2 Front Desk Section - 2 1" = 1'-0"5Front Desk Det. Section 1 1" = 1'-0"7Front Desk Det. Section 3 1" = 1'-0"6Front Desk Det. Section 2 1" = 1'-0"8 Front Desk Det. Section 4 1" = 1'-0"9Front Desk Det. Section 5 1" = 1'-0"3Front Desk Section - 3 1" = 1'-0"4Front Desk Section - 4 0'6" 1'2' SCALE: 1" = 1'-0" EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV Revision Schedule Number Description Date AFF 8'-0" ALL SURFACES PLASTICLAMINATE OR WOOD TO MATCHPL-01 UNLESS NOTED OTHERWISE 2CM ENGINEERED STONE TOP AND BACK SPLASH PLASTIC LAMINATE OR WOODVENEER BACK PANEL TOMATCH PL-03 ADJUSTABLE SHELF PULL HARDWARE FINISH TO MATCHDAYBREAK: PT-04DUSK: PT-05 INTERIOR FINISH TO BE WHITEMELAMINE UNLESS NOTED OTHERWISE ALL SURFACES PLASTIC LAMINATEOR WOOD TO MATCH PL-01 UNLESSNOTED OTHERWISE3/4"3" 2' - 1"4"5 EQUAL DRAWERS0' - 0 3/4"3'-0" (2'-9 1/2" AT ACCESSIBLE ROOMS)4' - 5 1/4"2' - 8 3/4"1' - 3"1' - 5 1/4"UNDERCABINET LIGHTING AFF 8'-0" ALL SURFACES PLASTICLAMINATE OR WOOD TO MATCHPL-01 UNLESS NOTED OTHERWISE 2CM ENGINEERED STONE TOP AND BACK SPLASH 1' - 8"1' - 5 1/2"1 1/2"1' - 0 1/4"1 1/2"1' - 3" OPEN SHELF MICRO COOKTOP ℄ PLASTIC LAMINATE OR WOODVENEER BACK PANEL TOMATCH PL-03 GAP FOR MICROWAVE WIREMANAGEMENT PULL HARDWARE FINISH TO MATCHDAYBREAK: PT-04DUSK: PT-05 INTERIOR FINISH TO BE WHITEMELAMINE UNLESS NOTED OTHERWISE ALL SURFACES PLASTIC LAMINATEOR WOOD TO MATCH PL-01 UNLESSNOTED OTHERWISE ADJUSTABLE SHELF TOMATCH PL-01 1' - 8" 0' - 3" 2' - 1"0' - 4"4' - 5 1/4"3'-0" (2'-9 1/2" AT ACCESSIBLE ROOMS)6"0' - 3" AFF 8'-0" ALL SURFACES PLASTICLAMINATE OR WOOD TO MATCHPL-01 UNLESS NOTED OTHERWISE 2CM ENGINEERED STONE TOP AND BACK SPLASH 3" 2' - 1"4"3/4"1' - 5 1/2"1 1/2"1' - 0 1/4"1 1/2"1' - 3" OPEN SHELF MICRO COOKTOP ℄ PLASTIC LAMINATE OR WOODVENEER BACK PANEL TOMATCH PL-03 GAP FOR MICROWAVE WIREMANAGEMENT PULL HARDWARE FINISH TO MATCHDAYBREAK: PT-04DUSK: PT-05 INTERIOR FINISH TO BE WHITEMELAMINE UNLESS NOTED OTHERWISE ALL SURFACES PLASTIC LAMINATEOR WOOD TO MATCH PL-01 UNLESSNOTED OTHERWISE2 EQ DRAWERS3'-0" (2'-9 1/2" AT ACCESSIBLE ROOMS)4' - 5 1/4"2' - 8 3/4"1' - 8" ADJUSTABLE SHELF AFF 8'-0" ALL SURFACES PLASTICLAMINATE OR WOOD TO MATCHPL-01 UNLESS NOTED OTHERWISE 2CM ENGINEERED STONE TOP AND BACK SPLASH 3" 2' - 1"4"3 EQUAL DRAWERS3/4"1' - 8"3' - 0"1' - 5 1/4"1' - 5 1/2"1 1/2"1' - 0 1/4"1 1/2"1' - 3" OPEN SHELF MICRO COOKTOP ℄ PLASTIC LAMINATE OR WOODVENEER BACK PANEL TOMATCH PL-03 GAP FOR MICROWAVE WIREMANAGEMENT PULL HARDWARE FINISH TO MATCHDAYBREAK: PT-04DUSK: PT-05 INTERIOR FINISH TO BE WHITEMELAMINE UNLESS NOTED OTHERWISE ALL SURFACES PLASTIC LAMINATEOR WOOD TO MATCH PL-01 UNLESSNOTED OTHERWISE AFF 8'-0" 2' - 1"3'-0" (2'-9 1/2" AT ACCESSIBLE ROOMS)3/4"1/2"4' - 5 1/4"2' - 8 3/4"1' - 3"3/4"ALL SURFACES PLASTICLAMINATE OR WOOD TO MATCHPL-01 UNLESS NOTED OTHERWISE 2CM ENGINEERED STONE TOP AND BACK SPLASH PLASTIC LAMINATE OR WOODVENEER BACK PANEL TOMATCH PL-03 ADJUSTABLE SHELF UNDERCABINET LIGHTING PULL HARDWARE FINISH TO MATCHDAYBREAK: PT-04DUSK: PT-05 GROMMET FOR CORDMANAGEMENT ALL SURFACES PLASTIC LAMINATEOR WOOD TO MATCH PL-01 UNLESSNOTED OTHERWISE DW AFF 8'-0"5' - 10 3/4"1' - 1 3/4"1 1/2"1' - 3" PLASTIC LAMINATE OR WOODVENEER BACK PANEL TOMATCH PL-03 REMOVABLE PANELPLASTIC LAMINATE ORWOOD TO MATCH PL-01 0' - 3" 2' - 1"0' - 4"3' - 0"4' - 5 1/4"0' - 6"2' - 8 3/4"0' - 1 1/2"1' - 2"0' - 1 1/2"1' - 2 1/4"0' - 1 1/2"1' - 3" AFF 8'-0"3/4"ALL SURFACES PLASTIC LAMINATEOR WOOD TO MATCH PL-01UNLESS NOTED OTHERWISE GAP FOR MICROWAVE WIRE MANAGEMENT 2CM ENGINEERED STONE TOP AND BACK SPLASH PULL HARDWARE FINISH TO MATCHDAYBREAK: PT-04DUSK: PT-05 INTERIOR FINISH TO BE WHITEMELAMINE UNLESS NOTED OTHERWISE ALL SURFACES PLASTIC LAMINATE OR WOODTO MATCH PL-01 UNLESS NOTED OTHERWISE NOTE: CONSTRUCTION SHOULD ALWAYS USEA MARINE GRADE PLYWOOD SUBSTRATE UNDERCABINET LIGHTING PLASTIC LAMINATE OR WOODVENEER BACK PANEL TOMATCH PL-03 OPEN SHELF OPEN SHELF 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216MILLWORK DETAILS-GUESTROOM KITCHENS A-708 FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 0'6" 1'2' SCALE: 1" = 1'-0" 1" = 1'-0"1GR KITCHEN SECTION-5 DRAWER CABINET 1" = 1'-0"2GR KITCHEN SECTION-COOKTOP WITH 1 DRAWER & 1 DOOR 1" = 1'-0"3 GR KITCHEN SECTION-COOKTOP WITH 2 DRAWERS & 1 DOOR 1" = 1'-0"4GR KITCHEN SECTION-COOKTOP WITH 3 DRAWERS 1" = 1'-0"5GR KITCHEN SECTION-DISHWASHER 1" = 1'-0"6GR KITCHEN SECTION-REF 1" = 1'-0"7 GR KITCHEN SECTION-SINK EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV Revision Schedule Number Description Date AFF 8'-0"4' - 0" MAX8" MIN 9" MIN11" MIN2' - 9 1/4" MAX1' - 1 1/4"3' - 3 1/2"2' - 3" MIN0' - 5 1/2"0' - 4"10 1/2"1' - 3" INTERIOR FINISH TO BE WHITE MELAMINEUNLESS NOTED OTHERWISE PULL HARDWARE FINISH TO MATCHDAYBREAK: PT-04DUSK: PT-05 ALL SURFACES PLASTIC LAMINATEOR WOOD TO MATCH PL-01 UNLESSNOTED OTHERWISE ADJUSTABLE SHELF TO MATCH PL-01 UNDERCABINET LIGHTING 2CM ENGINEERED STONE TOP ANDBACKSPLASH TO MATCH SS-01 INTERIOR FINISH TO BE WHITEMELAMINE UNLESS NOTED OTHERWISE REMOVABLE MILLWORK PANEL VERTICAL PANEL SUPPORT FINISHED SIDE OF BASE CABINET BEYOND AFF 8'-0" ALL SURFACES PLASTIC LAMINATEOR WOOD TO MATCH PL-01UNLESS NOTED OTHERWISE PLASTIC LAMINATE OR WOODVENEER BACK PANEL TOMATCH PL-03 3/4" MDF W/ WOOD VENEER OPEN CABINET WITH EXPOSED SHELVES (ALL SIDES TO BE FINISHED) OPEN SHELF OPEN SHELF UNDERCABINET LIGHTING 2CM ENGINEERED STONETOP AND BACKSPLASH TOMATCH SS-01 ALL PLUMBING AND EQUIPMENT BELOW THE SINK IN ACCESSIBLE ROOMS MUST BE CONCEALED FROM GUEST VIEW REMOVABLE MILLWORK PANEL VERTICAL PANEL SUPPORT FINISHED SIDE OF BASE CABINET BEYOND 2' - 1"2' - 3" MIN6"2' - 9 1/2" MAX4' - 5 1/4"1 1/2"1' - 2 1/4"1 1/2"1' - 2"1 1/2"11" MIN 9" MIN1' - 3" AFF 8'-0" INTERIOR FINISH TO BE WHITE MELAMINEUNLESS NOTED OTHERWISE PULL HARDWARE FINISH TO MATCHDAYBREAK: PT-04DUSK: PT-05 ALL SURFACES PLASTIC LAMINATEOR WOOD TO MATCH PL-01 UNLESSNOTED OTHERWISE ADJUSTABLE SHELF TO MATCH PL-01 UNDERCABINET LIGHTING 2' - 9 1/4" MAX0' - 4"10 1/2"1' - 3"1' - 1 1/4"3' - 3 1/2"2CM ENGINEERED STONE TOP ANDBACKSPLASH TO MATCH SS-01 ADA DW ADA MICRO 4' - 0" MAX2' - 1" 1/2" AFF 8'-0" ALL SURFACES PLASTICLAMINATE OR WOOD TO MATCHPL-01 UNLESS NOTED OTHERWISE 2CM ENGINEERED STONE TOP AND BACK SPLASHCOOKTOP ℄ PLASTIC LAMINATE OR WOODVENEER BACK PANEL TOMATCH PL-03 PULL HARDWARE FINISH TO MATCHDAYBREAK: PT-04DUSK: PT-05 ALL SURFACES PLASTIC LAMINATEOR WOOD TO MATCH PL-01 UNLESSNOTED OTHERWISE ADJUSTABLE SHELF PULL HARDWARE FINISH TO MATCHDAYBREAK: PT-04DUSK: PT-05 ALL SURFACES PLASTIC LAMINATEOR WOOD TO MATCH PL-01 UNLESSNOTED OTHERWISE VENT HOOD 3" 2' - 1"4"2'-9 1/2" AT ACCESSIBLE ROOMS6"10"1' - 3"4' - 5 1/4"2' - 2 3/4"0' - 3" 1' - 8" 3" 2' - 5 1/2"4"3 EQUAL DRAWERS3' - 0"1 1/4"2CM ENGINEERED STONE TOP AND BACKSPLASH 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216MILLWORK DETAILS-ACCESSIBLEGUESTROOM KITCHENS A-709 FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 0'6" 1'2' SCALE: 1" = 1'-0" 1" = 1'-0"2GR KITCHEN SECTION-COUNTER ADA 1" = 1'-0"1GR KITCHEN SECTION-SINK ADA 1" = 1'-0"3 GR KITCHEN SECTION-DISHWASHER ADA 1" = 1'-0"4 GR KITCHEN SECTION-COOKTOP ADA 1" = 1'-0"5GW KITCHEN SECTION-3 DRAWER EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV Revision Schedule Number Description Date G 7 2 A-301 E 8 737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216MILLWORK DETAILS-MODIFIED FURNITURE A-710 FSC PROJECT NO. 21012 BID/PERMIT SET MAY 31, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 0'6" 1'2' SCALE: 1" = 1'-0" 1" = 1'-0"1Coffee Station Detail Plan 1" = 1'-0"2ACCESSIBLE GUEST BATH VANITY 1" = 1'-0"3GUEST BATH VANITY 1" = 1'-0"4 MEETING ROOM CREDENZA EXP.8/23/2025 REGISTEREDARCHITECT 13010 STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV Revision Schedule Number Description Date DESIGN CONDITIONS LOCATION SPOKANE VALLEY, WA CLIMATE ZONE 5B (SPOKANE COUNTY) OUTDOORS COOLING 96°F DB / 64°F WB HEATING 10°F DB INDOOR COOLING 75°F HEATING 72°F VENTILATION PER IMC/ASHRAE 62.1-2019 ELEVATION 2,400 FT ABOVE SEA LEVEL GENERAL HVAC NOTES 1. SHEET METAL DUCTWORK AND COMPONENTS INCLUDING HANGING, SEALING, PLENUMS, & ACCESSORIES SHALL BE CONSTRUCTED IN STRICT ACCORDANCE WITH THE LATEST EDITION OF SMACNA STANDARDS FOR HVAC DUCT CONSTRUCTION, NFPA 90A, & 90B STANDARDS. 2. ALL DUCTWORK OPENINGS SHALL BE COVERED DURING CONSTRUCTION. 3. ALL DAMPERS SHALL BE SET FULLY OPEN PRIOR TO BALANCING. 4. CONTRACTOR TO PROVIDE TRANSITION TO CONNECT TO ALL MECHANICAL EQUIPMENT. PROVIDE FLEXIBLE CONNECTION ON INTAKE AND DISCHARGE OF ALL MECHANICAL EQUIPMENT. 5. DUCT DIMENSIONS SHOWN ARE INSIDE SHEET METAL DIMENSIONS OR CLEAR OPENING INSIDE LINED DUCT. 6. DRAWINGS ARE DIAGRAMMATIC IN NATURE AND DO NOT ATTEMPT TO SHOW ALL REQUIRED OFFSETS. COORDINATE WITH OTHER TRADES AND PROVIDE ALL NECESSARY OFFSETS. 7. PROVIDE 1" THICK DUCT LINER IN ALL TRANSFER AIR DUCTWORK UNLESS NOTED OTHERWISE. 8. ALL ELBOWS SHALL BE LONG RADIUS ELBOWS WHEREVER POSSIBLE, OR SHALL HAVE TURNING VANES WHERE INDICATED ON PLANS. NO SQUARE THROAT OR ZERO RADIUS ELBOWS ALLOWED. 9. ALL DUCT BRANCH CONNECTIONS TO DIFFUSER OR GRILLES, TO OR FROM MAIN DUCTS, SHALL INCLUDE MANUAL VOLUME DAMPERS. ALL SPIN-IN FITTINGS SHALL BE CONICAL, RECTANGULAR BRANCH DUCT TAKEOFFS SHALL HAVE 45° TAKEOFFS. 10. PROVIDE CONCEALED DAMPER REGULATORS OR ACCESS DOORS FOR ALL MANUAL VOLUME DAMPERS LOCATED THAT ARE INACCESSIBLE. REFER TO ARCHITECTURAL DRAWINGS FOR CEILING TYPES. ALL FINAL ACCESS DOOR LOCATIONS SHALL BE APPROVED BY ARCHITECT PRIOR TO INSTALLATION. 11. 24"x24" ACCESS DOORS SHALL BE PROVIDED FOR ALL MECHANICAL EQUIPMENT LOCATED ABOVE GYPSUM BOARD CEILINGS. ALL FINAL ACCESS DOOR LOCATIONS SHALL BE APPROVED BY ARCHITECT PRIOR TO INSTALLATION. 12. PROVIDE DIFFUSER AND GRILLE FRAMES COMPATIBLE WITH ARCHITECTURAL CEILING TYPES AND COORDINATE LOCATIONS WITH THE ARCHITECTURAL REFLECTED CEILING PLAN AND ELECTRICAL LIGHTING LAYOUT. 13. ALL DUCTWORK VISIBLE THROUGH RETURN OR SUPPLY GRILLES TO BE PAINTED FLAT BLACK. 14. ALL SUPPLY, RETURN AND EXHAUST AIR DUCTS SHALL HAVE THE TRANSVERSE JOINTS, LONGITUDINAL SEAMS, AND DUCT WALL PENETRATIONS SEALED AIRTIGHT WITH DUCT SEALANT (SMACNA SEAL CLASS "A"). 15. COORDINATE EXACT LOCATIONS OF ALL ROOM THERMOSTATS AND/OR ROOM TEMPERATURE SENSORS WITH ARCHITECT/OWNER PRIOR TO INSTALLATION. 16. BALANCE AIR SYSTEM TO QUANTITIES SHOWN, AND SUBMIT A COPY OF THE BALANCE REPORT TO THE ENGINEER FOR REVIEW. GENERAL NOTES 1. CONTRACTOR SHALL SECURE, MAINTAIN, AND PAY FOR ALL REQUIRED PERMITS, LICENSES, AND INSPECTIONS FOR DURATION OF WORK UNLESS DIRECTED OTHERWISE. 2. ALL WORK SHALL COMPLY WITH THE OWNER'S REQUIREMENTS, AND WITH ALL APPLICABLE STATE AND LOCAL CODES, OR AUTHORITY HAVING JURISDICTION. 3. SUBSTITUTIONS OF EQUIPMENT OTHER THAN AS SPECIFIED SHALL BE THE COMPLETE RESPONSIBILITY OF THE CONTRACTOR, ANY ADDITIONAL ELECTRICAL, STRUCTURAL, MECHANICAL, OR ARCHITECTURAL REQUIREMENTS SHALL BE PROVIDED AT NO ADDITIONAL EXPENSE TO THE OWNER. 4. DRAWINGS ARE DIAGRAMMATIC IN NATURE AND DO NOT ATTEMPT TO SHOW ALL REQUIRED OFFSETS. COORDINATE WITH OTHER TRADES AND PROVIDE ALL NECESSARY OFFSETS. REFER TO ARCHITECTURAL AND STRUCTURAL DRAWINGS FOR CONSTRUCTION DETAILS. 5. REFER TO PROJECT MANUAL (SPECIFICATIONS) FOR ADDITIONAL REQUIREMENTS. PLANS AND SPECIFICATIONS SHALL BE TAKEN TOGETHER. PROVIDE ALL WORK CALLED FOR IN EITHER. IN CASE OF CONFLICT BETWEEN SPECIFICATIONS AND PLANS THE MORE STRINGENT SHALL APPLY. 6. ALL EQUIPMENT AND MATERIAL ON THE JOB SITE PRIOR TO INSTALLATION SHALL BE COVERED AND PROTECTED FROM RAIN, DIRT, DUST, AND DAMAGE. 7. VERIFY PHYSICAL DIMENSIONS OF EQUIPMENT TO ENSURE THAT ACCESS CLEARANCES CAN BE MET. COORDINATE FINAL EQUIPMENT LOCATIONS W/ GENERAL CONTRACTOR AND OTHER TRADES TO ALLOW FOR REQUIRED MECHANICAL EQUIPMENT CLEARANCES. 8. PROVIDE AN UNOBSTRUCTED PASSAGEWAY MEASURING NO LESS THAN 36" WIDE BY 80" HIGH FROM DOOR INTO THE SPACE TO SERVICEABLE MECHANICAL EQUIPMENT. A LEVEL WORKING SPACE MEASURING NO LESS THAN 30" WIDE BY 36" DEEP MUST BE PROVIDED IN FRONT OF CONTROL SIDE OF EQUIPMENT FOR SERVICING. 9. PROVIDE NEC CODE MINIMUM HORIZONTAL AND VERTICAL WORKING CLEARANCES FOR ALL ELECTRICAL PANELS AND EQUIPMENT. OFFSET MECHANICAL WORK AS REQUIRED. 10. CONTRACTOR IS RESPONSIBLE FOR VERIFICATION OF INSTALLATION STANDARDS AND CONSTRUCTION CONDITIONS. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS PRIOR TO SHOP FABRICATION AND/OR FIELD INSTALLATION. DISCREPANCIES BETWEEN EXISTING CONDITIONS AND THE CONSTRUCTION DRAWINGS SHALL BE CALLED TO THE ATTENTION OF THE ENGINEER. 11. ALL MECHANICAL EQUIPMENT, MATERIALS, AND INSTALLATION SHALL BE PROVIDED BY THE CONTRACTOR. ALL EQUIPMENT SHALL BE COMPLETE, INSTALLED, AND FULLY FUNCTIONAL PRIOR TO FINAL ACCEPTANCE OF THE WORK. 12. INSTALL ALL EQUIPMENT PER MANUFACTURERS RECOMMENDATIONS AND REQUIREMENTS. ANY CONFLICTS BETWEEN THE MANUFACTURERS DOCUMENTATION AND THE CONTRACT DOCUMENTS SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER. 13. DO NOT ALLOW ANY WORK TO BE COVERED UP OR ENCLOSED UNTIL INSPECTED, TESTED AND APPROVED BY OWNER'S REPRESENTATIVE OR AUTHORITY HAVING JURISDICTION. 14. MECHANICAL EQUIPMENT SHALL NOT BE USED FOR TEMPORARY HEATING OR COOLING DURING CONSTRUCTION. 15. PIPES AND WIRING IN PLENUM SHALL BE RATED FOR PLENUM USE. PVC, ABS, AND PLASTIC PIPING IS NOT ACCEPTABLE IN PLENUM APPLICATIONS. 16. ALL DETAILS ARE TYPICAL UNLESS NOTED OTHERWISE. GENERAL PLUMBING NOTES 1. PROVIDE ALL LABOR, MATERIALS, AND EQUIPMENT NECESSARY TO CONSTRUCT A COMPLETE, OPERATIONAL PLUMBING SYSTEM FOR THE ENTIRE PROJECT AS SHOWN ON THESE DRAWINGS, INCLUDING ALL NECESSARY FEES AND PERMITS. 2. THE ENTIRE INSTALLATION SHALL CONFORM TO THE MOST RECENTLY ADOPTED REQUIREMENTS OF THE PLUMBING CODE, AND ALL OTHER APPLICABLE CITY, COUNTY, STATE, AND FEDERAL CODES AND REGULATIONS IN EFFECT AT THE DATE OF THE BID. CONFORM TO ANY CODES, RULES, REGULATIONS AND REQUIREMENTS THAT THE PROJECT OWNER HAS. 3. PRIOR TO FABRICATION AND INSTALLATION, THE CONTRACTOR SHALL COORDINATE THE INSTALLATION OF ALL PLUMBING WORK WITH ALL OTHER TRADES INCLUDING THE MECHANICAL CONTRACTOR, FIRE PROTECTION CONTRACTOR, ELECTRICAL CONTRACTOR, GENERAL CONTRACTOR, AND ANY CONTRACTOR HIRED DIRECTLY BY THE OWNER. WHERE CONFLICTS MAY OCCUR, THEY SHALL BE RESOLVED PRIOR TO INSTALLATION. 4. THE WORKING DRAWINGS ARE DIAGRAMMATIC. BECAUSE OF THE SMALL SCALE OF THE DRAWINGS, THEY DO NOT SHOW EVERY OFFSET, BEND OR ELBOW NECESSARY FOR THE COMPLETE INSTALLATION IN THE SPACE PROVIDED. ALL LOCATIONS FOR PLUMBING EQUIPMENT AND PIPING SHALL BE CHECKED AND COORDINATED WITH THE ARCHITECTURAL, MECHANICAL, STRUCTURAL AND ELECTRICAL DRAWINGS. 5. ALL EQUIPMENT SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THE EQUIPMENT MANUFACTURER'S RECOMMENDATIONS. PROVIDE ALL FITTINGS, TRANSITIONS, VALVES, WORKING CLEARANCES, AND OTHER DEVICES AND ACCESSORIES REQUIRED FOR A COMPLETE, WORKABLE INSTALLATION. 6. PROVIDE PROPER PROVISIONS FOR EXPANSION OR MOVEMENT OF ALL PIPING. 7. PROVIDE WATER HAMMER ARRESTORS (SHOCK ABSORBERS) AT ALL PIPE LOCATIONS WHERE VALVE CLOSURES MAY CAUSE WATER HAMMER OR RESULT IN EXCESSIVE PIPE VIBRATION OR MOVEMENT. (EXAMPLES INCLUDE FLUSH VALVES, SENSOR FAUCETS, AND WASHING MACHINES). 8. PROVIDE CLEANOUTS AS REQUIRED BY CODE, INCLUDING AT ALL SINKS, URINALS AND END OF RUNS. GENERAL ABBREVIATIONS ø ROUND or DIAMETER AAV AUTOMATIC AIR VENT ABV ABOVE AD ACCESS DOOR AFF ABOVE FINISH FLOOR AHU AIR HANDLING UNIT AL ACOUSTIC LINED AP ACCESS PANEL APD AIR PRESSURE DROP ASME AMERICAN SOCIETY OF MECHANICAL ENGINEERS AWT AVERAGE WATER TEMPERATURE BB BASEBOARD BBD BACKDRAFT DAMPER BFF BELOW FINISH FLOOR BHP BRAKE HORSEPOWER BG BELOW GROUND/GRADE BTU BRITISH THERMAL UNIT BTUH BRITISH THERMAL UNITS PER HOUR C CENTIGRADE CC COOLING COIL CD CEILING DIFFUSER CFM CUBIC FEET PER MINUTE CG CEILING GRILLE CI CAST IRON CLG CEILING CO CLEANOUT COG CLEANOUT TO GRADE CMU CONCRETE MASONRY UNIT CM CONDENSATE METER CONC CONCRETE CONN CONNECT or CONNECTION CONST CONSTRUCTION CONT CONTINUATION (D) DEMOLISH DB DECIBEL or DRY BULB DDC DIRECT DIGITAL CONTROL DIA DIAMETER DIM DIMENSION DN DOWN DOAS DEDICATED OUTDOOR AIR SYSTEM DPR DAMPER DPS DIFFERENTIAL PRESSURE SWITCH DWG DRAWING (E) EXISTING EA EACH EAT ENTERING AIR TEMPERATURE EF EXHAUST FAN EG EXHAUST GRILLE ELEC ELECTRIC or ELECTRICAL ELEV ELEVATION EMCS ENERGY MANAGEMENT CONTROL SYSTEM ERV ENERGY RECOVERY VENTILATOR ESP EXTERNAL STATIC PRESSURE EWT ENTERING WATER TEMPERATURE EXH EXHAUST EXST EXISTING F FAHRENHEIT FCO FLOOR CLEANOUT FCU FAN COIL UNIT FD FLOOR DRAIN FD FIRE DAMPER FFD FUNNEL FLOOR DRAIN FF FINAL FILTER FLR FLOOR FPM FEET PER MINUTE FPS FEET PER SECOND FS FLOOR SINK FSD COMBINATION FIRE/SMOKE DAMPER FT FOOT/FEET FTR FINNED TUBE RADIATION FV FACE VELOCITY GA GAGE or GAUGE GAL GALLON GALV GALVANIZED GPH GALLONS PER HOUR GPM GALLONS PER MINUTE GRD GRILLE, REGISTER, OR DIFFUSER H HEIGHT HB HOSE BIBB HD HEAD HP HORSEPOWER HRV HEAT RECOVERY VENTILATOR HTG HEATING HVAC HEATING, VENTILATION AND AIR CONDITIONING HWG HIGH WALL GRILLE HWR HIGH WALL REGISTER HZ HERTZ ID INSIDE DIAMETER IE INVERT ELEVATION IN INCH or INCHES INSUL INSULATION INV INVERT KH KICKSPACE HEATER KW KILOWATT KWH KILOWATT HOUR L LENGTH LAT LEAVING AIR TEMPERATURE LBS POUNDS LF LINEAR FOOT/FEET LVG LEAVING LWG LOW WALL GRILLE LWR LOW WALL REGISTER LWT LEAVING WATER TEMPERATURE MAX MAXIMUM MAV MANUAL AIR VENT MBH 1000 BRITISH THERMAL UNITS PER HOUR MCA MINIMUM CIRCUIT AMPACITY MCC MOTOR CONTROL CENTER MFR MANUFACTURER MOP MAXIMUM OVERCURRENT PROTECTION MUA MAKEUP AIR UNIT MIN MINIMUM MISC MISCELLANEOUS MTD MOUNTED MTG MOUNTING (N) NEW (NL) NEW LOCATION N/A NOT APPLICABLE N/C NORMALLY CLOSED N/O NORMALLY OPEN NC NOISE CRITERIA N.I.C. NOT IN CONTRACT NPT NATIONAL PIPE THREAD NTS NOT TO SCALE OA OUTSIDE AIR OBD OPPOSED BLADE DAMPER O/C ON CENTER OD OUTSIDE DIAMETER OPNG OPENING PVC PRESSURE CONTROL VALVE PD PRESSURE DROP PH PHASE PLCS PLACES POC POINT OF CONNECTION POUA POINT OF USE ALARM PRV PRESSURE REDUCING VALVE PSI POUNDS PER SQUARE INCH PSIG POUNDS PER SQUARE INCH (GAGE) (REL) RELOCATE/RELOACTED RA RETURN AIR RAG RETURN AIR GRILLE REQD REQUIRED R.O. ROUGH OPENING RPBP REDUCED PRESSURE BACKFLOW PREVENTER RPM REVOLUTIONS PER MINUTE SA SUPPLY AIR SD SMOKE DETECTOR SF SUPPLY FAN SHT SHEET SIM SIMILAR SL SOUNDLINING SP STATIC PRESSURE SQ SQUARE SQ FT SQUARE FOOT/FEET SS STAINLESS STEEL STD STANDARD TAB TESTING, ADJUSTING & BALANCING THK THICK TP TRAP PRIMER or TEST PLUG TSP TOTAL STATIC PRESSURE TYP TYPICAL TU TERMINAL UNIT UBC UNIFORM BUILDING CODE UFC UNIFORM FIRE CODE UMC UNIFORM MECHANICAL CODE UPC UNIFORM PLUMBING CODE UG UNDERGROUND UH UNIT HEATER UNO UNLESS NOTED OTHERWISE VA VALVE VAC VACUUM VAV VARIABLE AIR VOLUME VD VOLUME DAMPER VEL VELOCITY VFD VARIABLE FREQUENCY DRIVE VRF VARIABLE REFRIGERANT FLOW VTR VENT THRU ROOF W WIDE W/ WITH W/O WITHOUT WB WET BULB WC WATER COLUMN WCO WALL CLEANOUT WG WATER GAGE WGE WASTE GAS EVACUATION WH WALL HYDRANT WPD WATER PRESSURE DROP WT WEIGHT GENERAL LEGEND THERMOSTAT. ADJACENT NUMBER INDICATES TERMINAL UNIT CONTROLLED HUMIDISTAT SENSOR CO2 SENSORCO2 T H S PLUMBING FIXTURE TAG, SEE PLUMBING SCHEDULES NOTES: XX-X SPECIFIC TO LOCATION(S) INDICATED. A. NOTE APPLIES TO ENTIRE SHEET. EXISTING NEW (E) (N) EXISTING (THIN) NEW (MEDIUM) POINT OF CONNECTION (POC) 1 EXISTING TO BE DEMOLISHED MECHANICAL EQUIPMENT, SEE MECHANICAL SCHEDULES.XX-X x SD DUCT SMOKE DETECTOR SP DUCT STATIC PRESSURE LINETYPES: B A A B _____________________ DETAIL SYMBOL: A = IDENTIFYING NUMBER B = SHEET WHERE DETAIL IS SHOWN SECTION SYMBOL: A = IDENTIFYING NUMBER B = SHEET WHERE DETAIL IS SHOWN NEW LOCATION(NL) RELOCATED(REL) HVAC DUCTWORK LEGEND DUCTWORK 24x12 S/A RECTANGULAR DUCT SIZE (INCHES) FIRST DIMENSION IS SIDE OF DUCT SHOWN DUCT SIZES SHOWN ON DRAWINGS ARE CLEAR INSIDE DIMENSIONS OF DUCT. DUCT SIZE SHOWN DOES NOT INCLUDE INSULATION OR LINING UNLESS NOTED OTHERWISE. SEE BELOW FOR DUCT SIZE TAG LEGEND. DUCT SIZE DUCT SYSTEM ABBREVIATION (NOT ALWAYS BE SHOWN) INSULATED DUCT SOUND LINED DUCT 24x12ø FLAT OVAL DUCT SIZE (INCHES) FIRST DIMENSION IS SIDE OF DUCT SHOWN 24ø ROUND DUCT 18ø24x12 CHANGE IN DUCT SIZE AND/OR SHAPE SUPPLY AIR (SA) OUTSIDE AIR (OSA) RECTANGULAR DUCT TURNED UP/SECTION ROUND/FLAT OVAL DUCT TURNED UP/SECTION RECTANGULAR DUCT TURNED DOWN/AWAY ROUND/FLAT OVAL DUCT TURNED DOWN/AWAY RETURN AIR (RA) RECTANGULAR DUCT TURNED UP/SECTION ROUND/FLAT OVAL DUCT TURNED UP/SECTION RECTANGULAR DUCT TURNED DOWN/AWAY ROUND/FLAT OVAL DUCT TURNED DOWN/AWAY EXHAUST AIR (EA) RECTANGULAR DUCT TURNED UP/SECTION ROUND/FLAT OVAL DUCT TURNED UP/SECTION RECTANGULAR DUCT TURNED DOWN/AWAY ROUND/FLAT OVAL DUCT TURNED DOWN/AWAY DAMPERS VOLUME/BALANCING DAMPER FIRE DAMPER (FD) SMOKE DAMPER (SD) FIRE/SMOKE DAMPER (FSD) BACKDRAFT DAMPER CONSTANT VOLUME DAMPER DUCT SYSTEM ABBREVIATIONS A SUPPLY AIRSA OUTSIDE AIROA COMBUSTION AIRCA RETURN AIRRA TRANSFER AIRTA EXHAUST AIREA FLEXIBLE DUCT DUCT SYMBOLS DUCT END CAP DUCT ACCESS DOOR AD SUPPLY AIR (SA) OR OUTSIDE AIR (OA) TERMINAL RETURN AIR (RA) OR TRANSFER AIR (TA) TERMINAL AIR TERMINAL IDENTIFICATION EXHAUST AIR (EA) TERMINAL GRILLE, REGISTER, OR OPEN DUCT X CFM AIRFLOW DIRECTION SOUND ATTENUATOR OR X-CFM MOTORIZED DAMPER M PLUMBING LEGEND COLD WATER (CW)W SANITARY WASTE ABOVE GRADE (W) HOT WATER (HW) HOT WATER CIRCULATING (HWC) 140° HOT WATER (HW) 140° HOT WATER CIRCULATING (HWC) 140 HW 140 HWC INDUSTRIAL COLD WATER (ICW)ICW TEMPERED WATER (TW)TW BGW SANITARY WASTE BELOW GRADE (BGW) PW PUMPED WASTE (PW) OW OILY WASTE (OW) V VENT - SANITARY (V) RAD RADON (RAD) RV RELIEF VENT (RV) RAIN LEADER (RD)RD OVERFLOW RAIN LEADER (ORD)ORDSTORM DRAIN (SD)SD TRAP PRIMER (TP)TP NATURAL GAS (G)G PLUMBING SYMBOLS & FIXTURE TAGS 2" FD-1 4" FCO 4" RD-1 4" COG 4" ORD-1 WC-1 DRAIN SIZE (SEE PLANS) DRAIN TYPE (SEE SCHEDULE) CLEANOUT SIZE (SEE PLANS) CLEANOUT TYPE (SEE SCHEDULE) 2 DFU DRAINAGE FIXTURE UNITS (MAY NOT BE SHOWN) 400 SQFT DRAIN SIZE (SEE PLANS) DRAIN TYPE (SEE SCHEDULE) AREA SERVED (MAY NOT BE SHOWN) FIXTURE TYPE (SEE SCHEDULE) 2 CWFU 4 DFU L-1 2 CWFU 2 HWFU 4 DFU COLD WATER FIXTURE UNITS HOT WATER FIXTURE UNITS DRAINAGE FIXTURE UNITS (SEE PLANS FOR FIXTURE SYMBOL) (FIXTURE UNITS MAY NOT BE SHOWN) 4" WCO CONDENSATE DRAIN (D)D 2" FS-1 165° HOT WATER (HW)140 HWC PLUMBING/PIPING SYMBOLS LEGEND VALVE GATE VALVE BALL VALVE GLOBE VALVE PLUG VALVE BUTTERFLY VALVE SPECIALTY VALVE OS & Y VALVE STOP COCK PRESSURE REDUCING VALVE PRESSURE REGULATING VALVE CHECK VALVE SPRING CHECK VALVE STRAINER STRAINER W/ BLOWDOWN BACKFLOW PREVENTER BALANCING VALVE AUTOMATIC BALANCING VALVE A RELIEF VALVE FUEL ANTI-SIPHON VALVE F FUSIBLE OIL SAFETY VALVE MOTORIZED VALVE NEEDLE VALVE M M SOLENOID VALVE S S AUTOMATIC CONTROL VALVE FLOW SWITCH PRESSURE SWITCH FS PS PIPE ELBOW DOWN (OR AWAY) PIPE ELBOW UP (OR TOWARDS) PIPE TEE DOWN (OR AWAY) PIPE TEE UP (OR AWAY) FLOW DIRECTION PIPE SLOPE & DIRECTION REDUCER, CONCENTRIC REDUCER, ECCENTRIC UNION FLANGES BLIND FLANGE END CAP PT PLUG (TEST PORT) FLEX CONNECTOR/ COUPLING EXPANSION JOINT EXPANSION GUIDE PIPE ANCHOR HOSE QUICK DISCONNECT HOSE THREAD DRAIN BALL VALVE HOSE BIBB WALL HYDRANT HOSE THREAD DRAIN VALVE FIRE DEPARTMENT CONNECTION WATER HAMMER ARRESTOR THERMOWELL THERMOMETER DIAL THERMOMETER T PRESSURE GAUGE W/ COCK P PRESSURE GAUGE W/ COCK & SIPHON P AIR VENT A - AUTOMATIC C - COIN M - MANUAL H - HIGH VOLUME A BASKET STRAINER AIR FILTER W/ COALESCER & DRAIN AIR FILTER W/ COALESCER, DRAIN, REGULATOR & GAUGE PUMP (SYMBOLIC - ARROW INDICATES FLOW DIRECTION) WATER METERM WATER HAMMER ARRESTOR (PLAN) V# S=2% PROJECT SUMMARY HOMEWOOD SUITES IS A NEW-CONSTRUCTION 5-STORY HOTEL. THE GROUND FLOOR HAS A LOBBY, POOL, WORKOUT ROOM, COMMON AREAS, AND SOME GUEST ROOMS, THE FLOORS ABOVE ARE GUEST ROOMS WITH A FEW SUPPORT ROOMS. THE MECHANICAL SYSTEMS USED IN THIS BUILDING INCLUDE AN ENERGY RECOVERY DOAS UNIT PROVIDING OUTDOOR AIR AND EXHASUT AIR TO EACH SPACE IN THE BUILDING OTHER THAN THE POOL AREA. HEATING AND COOLING FOR THESE SPACES WILL BE PROVIDED BY DEDICATED IN-ROOM UNITS FOR THE GUEST ROOMS AND A VRF SYSTEM FOR THE GROUND FLOOR. THE POOL AREA WILL BE SERVED BY AN AIR HANDLING UNIT THAT VENTILATES, CONDITIONS, AND DEHUMIDIFIES THE POOL AIR. THE PLUMBING SYSTEM COMPOSES OF A HOT WATER RECIRCULATION LOOP TO ALL FLOORS OF THE BUILDING WITH NATURAL GAS WATER HEATERS ON THE GROUND FLOOR. THE NEW EQUIPMENT WILL MEET ALL CURRENT APPLICABLE CODE AND USER REQUIREMENTS. THE ELECTRICAL DRAWINGS DETAIL THE ELECTRICAL-SPECIFIC REQUIREMENTS IN ACCORDANCE WITH THE ABOVE. www.coffman.com 221 N. Wall Street, Suite 500 Spokane, WA 99201 ph 509.328.2994 32 MERCHANT STREET, SUITE 208 HONOLULU, HI 96813 808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 99216GENERAL MECHANICAL NOTES AND LEGENDS M-001 FSC PROJECT NO. 21012 PERMIT SET MAY 30, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce Lane Spokane, WA 99206 (509) 919-0901 MECHANICAL SHEET INDEX SHEET NUMBER SHEET NAME M-001 GENERAL MECHANICAL NOTES AND LEGENDS M-100 GROUND FLOOR ZONE PLAN M-101 GROUND FLOOR MECHANICAL PLAN M-102 2ND FLOOR MECHANICAL PLAN M-103 3RD FLOOR MECHANICAL PLAN M-104 4TH FLOOR MECHANICAL PLAN M-105 5TH FLOOR MECHANICAL PLAN M-106 MECHANICAL ROOF PLAN M-401 ENLARGED MECHANICAL PLANS M-402 ENLARGED MECHANICAL PLANS M-601 MECHANICAL CONTROL DIAGRAMS M-701 MECHANICAL SCHEDULES M-702 MECHANICAL SCHEDULES M-703 MECHANICAL SCHEDULES P-100 UNDERFLOOR PLUMBING PLAN P-101 GROUND FLOOR PLUMBING PLAN P-102 2ND FLOOR PLUMBING PLAN P-103 3RD FLOOR PLUMBING PLAN P-104 4TH FLOOR PLUMBING PLAN P-105 5TH FLOOR PLUMBING PLAN P-106 PLUMBING ROOF PLAN P-111 GROUND FLOOR REFRIGERANT AND CONDENSATE PIPING PLAN P-112 2ND FLOOR REFRIGERANT AND CONDENSATE PIPING PLAN P-113 3RD FLOOR REFRIGERANT AND CONDENSATE PIPING PLAN P-114 4TH FLOOR REFRIGERANT AND CONDENSATE PIPING PLAN P-115 5TH FLOOR REFRIGERANT AND CONDENSATE PIPING PLAN P-401 ENLARGED PLUMBING PLANS P-402 ENLARGED PLUMBING PLANS P-403 ENLARGED WATER HEATER ROOM P-501 PLUMBING DETAILS P-502 PLUMBING DETAILS P-601 WASTE AND VENT RISER DIAGRAM P-602 WASTE AND VENT RISER DIAGRAM P-603 DOMESTIC WATER RISER DIAGRAM P-604 DOMESTIC WATER RISER DIAGRAM P-605 CONDENSATE DRAIN RISER DIAGRAM P-701 PLUMBING SCHEDULES P-702 PLUMBING SCHEDULES Revision Schedule Number Description Date 5/30/2024 D D D D WWWW D D D D WWWW T T T T T T T T T T A A B B C C D C.1 E E F F G G H H J J K K L.1 L.1 M M N N P P Q Q 99 8.1 88 77 6.1 66 55 44 3.13.1 33 2.12.1 1.11.1 2 2 POOL & SPLASH PAD 101 PUBLIC CORRIDOR 100 ELECTRICAL 104 POOL RESTROOM 102 POOL MEP 103 STAIR 1 106 WATER HEATER & FIRE 108 BOH LAUNDRY 105 BOH DRYERS 105A LINEN DISCHARGE & SORTING 107 ELEV 1 111 ELEVATOR LOBBY 117 ELEV 2 113 EMPLOYEE ROOM 110 LAUNDRY LOUNGE 112 EMP RR 110B EMP RR ADA 110A LINEN STORAGE 109 HOUSEKEEPING OFFICE 109A FITNESS 114 MEN'S RESTROOM 116 WOMEN'S RESTROOM 115 GUEST STORAGE 118 MEETING STORAGE 119 MEETING ROOM 120 LOBBY 121 FOOD PREP 123 OPEN OFFICE 124 ELECTRICAL 128 VESTIBULE 122 COURTYARD STORAGE 141 EFFICIENCY 129 EFFICIENCY 131 EFFICIENCY 133 DOUBLE QUEEN 135 KING STUDIO 137 KING STUDIO ADA-M-T 138 DOUBLE QUEEN 136 EFFICIENCY 134 STAIR 2 132 KING STUDIO 130 GUEST CORRIDOR 139 ZONE 1 ZONE 2 ZONE 3 ZONE 4 ZONE 5 ZONE 6 ZONE 7 ZONE 8 1 ZONE 9 GM OFFICE 125 SALES OFFICE 126 OWNER'S OFFICE 127 FCU-216 FCU-217 FCU-215 FCU-311 FCU-212 BCU-02 FCU-211 EH-11 EH-12 FCU-213 AHU-01 AHU-01 UH-01 GENERAL NOTES A. ZONE PLAN PROVIDED FOR GROUND FLOOR ONLY. ALL GUEST ROOMS ARE INDIVIDUALLY ZONED BY PTAC. SEE ENLARGED GUEST ROOM PLANS FOR FURTHER DETAILS. B. THERMOSTAT LOCATION SHALL BE COORDINATED WITH OWNER AND ARCHITECT PRIOR TO FINAL PLACEMENT. C. NON-ADJUSTABLE DIGITAL TEMPERATURE SENSORS SHALL BE PROVIDED IN PUBLIC AREAS. UNLESS SPECIFICALLY NOTED ON PLANS, PUBLIC ZONES SHALL NOT BE ADJUSTABLE BY GUESTS. D. DUCTS SHALL BE CONSTRUCTED OF MINIMUM 26-GUAGE STEEL. DUCT PENETRATIONS THROUGH 1-HR OR LESS RATED FIRE PARTITIONS IN GUEST CORRIDOR DO NOT REQUIRE FIRE DAMPERS PER IBE 717.5.4 EXCEPTION 4. UH-02 www.coffman.com 221 N. Wall Street, Suite 500 Spokane, WA 99201 ph 509.328.2994 32 MERCHANT STREET, SUITE 208 HONOLULU, HI 96813 808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 99216GROUND FLOOR ZONE PLAN M-100 FSC PROJECT NO. 21012 PERMIT SET MAY 30, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce Lane Spokane, WA 99206 (509) 919-0901 3/32" = 1'-0" GROUND FLOOR ZONE PLAN 0'6'12'24' SCALE: 3/32" = 1'-0" KEY NOTES 1 MEETING ROOM THERMOSTAT MUST BE ADJUSTABLE BY GUESTS. 3/32" = 1'-0" STORAGE SHED ZONE PLAN Revision Schedule Number Description Date 5/30/2024 MMMMMMMMMMMMMMMMMAA A A A AA A A AAAAAAAAAAAAAAAAAAAAAAAAAAAAAM AMM A A B B C C D C.1 C.1 E E F F G G H H J J K K L.1 L.1 M M N N P P Q Q 99 8.1 88 77 6.1 66 55 44 3.13.1 33 2.12.1 1.11.1 2 2 MEN'S RESTROOM 116 WOMEN'S RESTROOM 115 MEETING STORAGE 119 MEETING ROOM 120 GUEST STORAGE 118 FITNESS 114 VESTIBULE 122 FOOD PREP 123 COURTYARD STORAGE 141 ELEV 2 113 ELEV 1 111 EFFICIENCY 129 EFFICIENCY 131 EFFICIENCY 133 KING STUDIO 130 STAIR 2 132 EFFICIENCY 134 GUEST CORRIDOR 139 ELEVATOR LOBBY 117 LOBBY 121 LAUNDRY LOUNGE 112 EMPLOYEE ROOM 110 WATER HEATER & FIRE 108 EMP RR ADA 110A POOL & SPLASH PAD 101 POOL RESTROOM 102 ELECTRICAL 104 STAIR 1 106 PUBLIC CORRIDOR 100 BOH LAUNDRY 105 LINEN STORAGE 109 LINEN CHUTE 140 LINEN DISCHARGE & SORTING 107 POOL MEP 103 DOUBLE QUEEN 135 KING STUDIO 137 DOUBLE QUEEN 136 KING STUDIO ADA-M-T 138 ? ?? ? ? ? OPEN OFFICE 124 ELECTRICAL 128 M-401 1 M-401 4 M-402 1 M-402 2 AHU-01 WH-2WH-1 WH-3 20x18 28x1218ø 18ø 12ø 12øFCU-213 FCU-212 FCU-216 DH-01 FCU-211 FCU-215 EH-11 6ø 10ø 10ø 8ø WH-4 2R 1651S 160 4S 2103E 150 1R 50 1S 160 FCU-217 6S 435 2S 25 6S 435 5S 435 2S 25 4E 200 5R 475 1E 50 1E 502E 100 2S 425 2S 50 5R 475 2S 60 8S 525 2S 25 2S 70 2R 165 4E 200 2R 165 1S 100 4R 435 2S 190 6S 325 6S 325 4S 190 6S 325 6S 325 4R 435 4R 4305E 285 5E 280 8S 635 8S 635 2S 255R 490 2S 25 6S 320 2S 160 2S 160 2S 25 2S 25 4R 4354S 195 6S 3101S 50 4R 4304S 190 4R 435 6S 310 6S 310 2S 150 6S 400 6S 4003E 150 1S 150 4S 300 6R 700 1S 100 4R 300 3E 150 3E 150 7R 1305 1S 150 1S 100 FCU-311 3E 115 2S 125 2S 100 1S 90 1S 50 1S 65 4ø 4ø6ø8ø10ø14ø 4ø6ø3E 100 16ø 16ø 12ø12ø 4ø12ø8ø 8ø 10ø 2S 1708ø10ø 4ø 12ø6ø6ø 4ø4ø14ø 10ø10ø12ø8ø12ø16ø12ø8ø 10ø10ø14ø 8ø12ø 20x1810ø 10ø14ø18x16 12ø 14ø 12ø10ø 8ø8ø8ø 8ø 8ø 8ø10ø 4ø16ø 12ø12ø16ø 12ø 4ø 4ø10ø12ø16ø12ø 10ø6ø 8ø10ø 6ø 16x1412x10 18x166ø 10ø12ø12ø12ø 14ø 4ø12x1010ø6ø6ø8ø4ø6ø 12ø9ø 4ø DRYER CLEANOUT 6ø 8ø 8ø 8ø12ø10ø 8ø 8ø6ø8ø 6ø 16ø16ø8ø 8ø 8ø 1 2 28x12 1E 50 7E 305 10ø 28x12 14x14 UP TO EF-02 18x18 UP TO EF-0110S 232 10S 232 10S 232 10S 232 10S 155 10S 206 10S 206 10S 206 EH-12 10S 155 10S 155 10S 155 10S 155 10S 155 10S 155 10S 155 10S 155 10S 155 8R 15508R 1550 UH-01 8ø 8ø16ø16ø 12ø 2R 200 10ø 10ø 14ø10ø 10ø 6ø 6R 635 6R 635 10ø 16ø 8ø EF-04 EF-05 18x16 FSD-11 FSD-12 4" FLUE VENT UP THROUGH ROOF 3 4 5LV-04 ALAL AL AL ALAL AL AL LV-02LV-01 FD-11 FD-12 14ø FCU-214 EF-03 14øSSLV-05 MAU-01 14x14 6 GENERAL NOTES A. MOTORIZED DAMPERS SHALL BE PROVIDED TO EACH GUEST ROOM PER WSEC C403.7.4.2 TO SERVE AS ISOLATION DEVICES CAPABLE OF AUTOMATICALLY SHUTTING OFF THE SUPPLY OF OUTDOOR AIR TO AND EXHAUST AIR FROM EACH GUEST ROOM. CONSTANT VOLUME DAMPER SHALL BE INSTALLED IN DUCT BRANCHES SERVING GUEST ROOMS, SET TO AUTOMATICALLY CONTROL AIRFLOW TO THE VALUES SHOWN ON PLANS; BASIS-OF- DESIGN IS ALDES CAR3. B. GUEST ROOM HEATING AND COOLING PTAC UNITS SHALL BE PROVIDED TO MEET WSEC C403.7.4.1 WITH CONTROLS CONFIGURED TO AUTOMATICALLY RAISE THE SET POINTS. C. REMOTE, WALL-MOUNTED, HARD-WIRED, ELECTRONIC DIGITAL THERMOSTAT SPECIFICALLY DESIGNED FOR GUEST SUITE APPLICATIONS MUST BE PROVIDED. STUDIO SUITES AND MULTI- ROOM SUITES, SERVED BY A SINGLE HVAC UNIT, MUST HAVE THE THERMOSTAT LOCATED IN THE MAIN SLEEPING AREA. GUEST ROOMS SERVED BY MULTIPLE HVAC UNITS MUST HAVE A THERMOSTAT FOR EACH HVAC UNIT LOCATED IN THE SPACE SERVED BY THAT UNIT. BATTERY POWERED THERMOSTATS ARE NOT ACCEPTABLE. D. DUCTWORK DIRECTLY SERVING THE POOL AND POOL MEP ROOMS SHALL BE CONSTRUCTED OF ALUMINUM. E. DUCTS SHALL BE CONSTRUCTED OF MINIMUM 26-GUAGE STEEL. DUCT PENETRATIONS THROUGH 1-HR (OR LESS) RATED FIRE PARTITIONS IN GUEST CORRIDOR DO NOT REQUIRE FIRE DAMPERS PER IBC 717.5.4 EXCEPTION 4. UH-02 www.coffman.com 221 N. Wall Street, Suite 500 Spokane, WA 99201 ph 509.328.2994 32 MERCHANT STREET, SUITE 208 HONOLULU, HI 96813 808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 99216GROUND FLOOR MECHANICAL PLAN M-101 FSC PROJECT NO. 21012 PERMIT SET MAY 30, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce Lane Spokane, WA 99206 (509) 919-0901 3/32" = 1'-0" GROUND FLOOR MECHANICAL PLAN 0'6'12'24' SCALE: 3/32" = 1'-0" KEY NOTES 1 INSTALL DRYER VENTING ACCORDING TO MANUFACTURER'S INSTRUCTIONS TO INCLUDE CLEARANCE MINIMUMS FROM GROUND LEVEL AND OTHER OPENINGS. DUCTWORK SHALL BE INSTALLED HIGH ENOUGH TO NOT PROHIBIT MAINTENANCE ACCESS IN THIS AREA. 2 INSTALL WATER HEATER CONCENTRIC VENTING ACCORDING TO MANUFACTURER'S INSTRUCTIONS TO INCLUDE CLEARANCE MINIMUMS/MAXIMUMS FROM GROUND LEVEL AND OTHER OPENINGS. BASIS-OF-DESIGN IS 4 CONCENTRIC PENETRATIONS IN A SQUARE PATTERN WITH END CAPS 0-2 INCHES APART. PENETRATIONS SHALL NOT BE LOCATED OVER DOORWAY OR WALKWAY. 3 INSTALL DRYER VENTING ACCORDING TO MANUFACTURES INTRUCTIONS TO INCLUDE CLEARANCE MINIMUMS FROM GROUND LEVEL AND OTHER OPENINGS. AT CONTRACTORS OPTION, COMBINED VENT SYSTEM MAY BE INSTALLED OR INDIVIDUAL VENTS FOR EACH DRYER; CLEANOUTS AND BACKDRAFT PROTECTION SHALL BE INSTALLED ACCORDING TO METHOD USED. WALL PENETRATION SHALL BE SEALED ACCORDING TO IMC SECTION 504. 4 GREASE DUCT SERVING KITCHEN HOOD SHALL BE 20-GA, 430 STAINLESS STEEL, LISTED TO UL-1978 (CAPTIVEAIRE SYSTEMS "DW") WITH SEALED CONNECTIONS AND FIRE BARRIER (3M FIRE BARRIER 2000 PLUS) INSTALLED ACCORDING TO MANUFACTURER'S INSTALLATIONS TO INCLUDE RATED ACCESS DOORS AND SLOPING. 5 INTER-LOCK CONTROL DAMPER AT LV-04 WITH ALL THREE CLOTHES DRYERS. IF ANY OF THE CLOTHES DRYERS IS OPERATING, LV-04 OPENS. IF ALL THREE DRYERS ARE OFF, LV-04 SHALL CLOSE. 6 KITCHEN HOOD MAKEUP AIR UNIT REQUIRES DOMESTIC COLD CONNECTION AND SANITARY WASTE CONNECTION. UNIT INSTALLED SUPPORTED FROM ABOVE. INSTALL VENT AND INTAKE PIPES THROUGH EXTERIOR WALL TO INTERNAL FURNACE COMPONENT ACCORDING TO MANUFACTURER'S INSTRUCTIONS. 3/32" = 1'-0" STORAGE SHED MECHANICAL PLAN Revision Schedule Number Description Date 5/30/2024 M M M M M M M MM M M M M M M M M M MMMMMMMMMM MMMMMM MMMMMMMMMMMMMMMMMMMMMMMMMMMMMA A AA A A A A A AA A A A A A A A A A A AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAM M A A B B C C D C.1 E E F F G G H H J J K K L.1 L.1 M M N N P P Q Q 99 8.1 88 77 6.1 66 5 44 3.13.1 33 2.12.1 1.1 2 2 ELEV 2 113 ELEV 1 111 LINEN CHUTE 140 KING STUDIO 237 KING STUDIO ADA-M-T 238 DOUBLE QUEEN 236 DOUBLE QUEEN 235 EFFICIENCY 233 KING 1-BEDROOM 202 KING 1-BEDROOM ENLARGED 201 DOUBLE QUEEN 210 KING STUDIO 204 DOUBLE QUEEN ENLARGED 212 KING STUDIO 214 ENGINEERING OFFICE & STORAGE 207 ELEVATOR LOBBY 217 LINENES & HOUSEKEEPING 209 EFFICIENCY ENLARGED 203 CONNECTING CORRIDOR 200 ? ? EFFICIENCY 229 EFFICIENCY 227 EFFICIENCY 208 EFFICIENCY 205 KING STUDIO 220 KING STUDIO 218 KING STUDIO 216 KING STUDIO 226 KING STUDIO 219 KING STUDIO 221 KING STUDIO 223 KING STUDIO 225 DOUBLE QUEEN 224 DOUBLE QUEEN 222 GUEST CORRIDOR 215 EFFICIENCY 228 EFFICIENCY 231 EFFICIENCY 234 KING STUDIO 230 STAIR 2 232 STAIR 1 206 PBX/MDF 207A M-402 3 M-402 4 M-401 3 M-401 5 CU-01 FCU-323 FCU-322 FCU-421 FCU-324 1S 25 1E 25 10ø 10ø 1E 55 FCU-321 2S 80 16x8 12x810ø 4ø 4ø 6ø8ø 10ø12ø EF-02 EF-01 EH-22 T T T 10ø 8ø 6ø 4ø 4ø4ø4ø4ø 4R 300 10ø 8ø 1S 50 6S 300FCU-326 T FCU-325 T 2S 50 26x104ø 4ø 6ø 4ø 16x8 16x8 12x8 FSD-21 FSD-22 4" DUCT HEATER VENT UP THROUGH ROOF EH-21 7S 600 7R 600 GENERAL NOTES A. MOTORIZED DAMPERS SHALL BE PROVIDED TO EACH GUEST ROOM PER WSEC C403.7.4.2 TO SERVE AS ISOLATION DEVICES CAPABLE OF AUTOMATICALLY SHUTTING OFF THE SUPPLY OF OUTDOOR AIR TO AND EXHAUST AIR FROM EACH GUEST ROOM. CONSTANT VOLUME DAMPER SHALL BE INSTALLED IN DUCT BRANCHES SERVING GUEST ROOMS, SET TO AUTOMATICALLY CONTROL AIRFLOW TO THE VALUES SHOWN ON PLANS; BASIS-OF- DESIGN IS ALDES CAR3. B. GUEST ROOM HEATING AND COOLING PTAC UNITS SHALL BE PROVIDED TO MEET WSEC C403.7.4.1 WITH CONTROLS CONFIGURED TO AUTOMATICALLY RAISE THE SET POINTS. C. REMOTE, WALL-MOUNTED, HARD-WIRED, ELECTRONIC DIGITAL THERMOSTAT SPECIFICALLY DESIGNED FOR GUEST SUITE APPLICATIONS MUST BE PROVIDED. STUDIO SUITES AND MULTI- ROOM SUITES, SERVED BY A SINGLE HVAC UNIT, MUST HAVE THE THERMOSTAT LOCATED IN THE MAIN SLEEPING AREA. GUEST ROOMS SERVED BY MULTIPLE HVAC UNITS MUST HAVE A THERMOSTAT FOR EACH HVAC UNIT LOCATED IN THE SPACE SERVED BY THAT UNIT. BATTERY POWERED THERMOSTATS ARE NOT ACCEPTABLE. D. DUCTWORK DIRECTLY SERVING THE POOL AND POOL MEP ROOMS SHALL BE CONSTRUCTED OF ALUMINUM. E. DUCTS SHALL BE CONSTRUCTED OF MINIMUM 26-GUAGE STEEL. DUCT PENETRATIONS THROUGH 1-HR (OR LESS) RATED FIRE PARTITIONS IN GUEST CORRIDOR DO NOT REQUIRE FIRE DAMPERS PER IBC 717.5.4 EXCEPTION 4. www.coffman.com 221 N. Wall Street, Suite 500 Spokane, WA 99201 ph 509.328.2994 32 MERCHANT STREET, SUITE 208 HONOLULU, HI 96813 808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 992162ND FLOOR MECHANICAL PLAN M-102 FSC PROJECT NO. 21012 PERMIT SET MAY 30, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce Lane Spokane, WA 99206 (509) 919-0901 3/32" = 1'-0" 2ND FLOOR MECHANICAL PLAN 0'6'12'24' SCALE: 3/32" = 1'-0" Revision Schedule Number Description Date 5/30/2024 MMM M M M M M MM M M M M M M M M M MMMMMMMMMM MMMMMM MMMMMMMMMMMMMMMMMMMMMMMMMMMMMA AA A A A A A AA A A A A A A A A A A AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAM A A A B B C C D C.1 E E F F G G H H J J K K L.1 L.1 M M N N P P Q Q 99 8.1 88 77 6.1 66 55 44 3.13.1 33 2.12.1 1.11.1 2 2 ELEV 2 113 ELEV 1 111 LINEN CHUTE 140 KING STUDIO 337 KING STUDIO ADA-M-RI 338 DOUBLE QUEEN 336 DOUBLE QUEEN 335 EFFICIENCY 333 KING 1-BEDROOM 302 KING 1-BEDROOM ADA-M-T 301 DOUBLE QUEEN 310 KING STUDIO 304 DOUBLE QUEEN ENLARGED 312 KING STUDIO 314 EFFICIENCY 307 ELEVATOR LOBBY 317 LINENES & HOUSEKEEPING 309 EFFICIENCY ENLARGED 303 CONNECTING CORRIDOR 300 ? ? EFFICIENCY 329 EFFICIENCY 327 EFFICIENCY 308 EFFICIENCY 305 KING STUDIO 320 KING STUDIO 318 KING STUDIO 316 KING STUDIO 326 KING STUDIO 319 KING STUDIO 321 KING STUDIO 323 KING STUDIO 325 DOUBLE QUEEN 324 DOUBLE QUEEN 322 GUEST CORRIDOR 315 EFFICIENCY 328 EFFICIENCY 331 EFFICIENCY 334 KING STUDIO 330 STAIR 2 332 STAIR 1 306 M-402 5 M-401 2 1S 25 1E 25 1E 55 2S 80 16x8 16x810ø 4ø 4ø 6ø8ø 10ø12ø 10ø 8ø 6ø 4ø 4ø4ø4ø 4R 300 10ø 8ø 1S 50 6S 300 2S 50 26x104ø 4ø 6ø 4ø 16x8 16x8 16x8 FSD-31 FSD-32 FCU-331 FCU-334 FCU-332 FCU-333 FCU-335 EH-32 4ø EH-31 GENERAL NOTES A. MOTORIZED DAMPERS SHALL BE PROVIDED TO EACH GUEST ROOM PER WSEC C403.7.4.2 TO SERVE AS ISOLATION DEVICES CAPABLE OF AUTOMATICALLY SHUTTING OFF THE SUPPLY OF OUTDOOR AIR TO AND EXHAUST AIR FROM EACH GUEST ROOM. CONSTANT VOLUME DAMPER SHALL BE INSTALLED IN DUCT BRANCHES SERVING GUEST ROOMS, SET TO AUTOMATICALLY CONTROL AIRFLOW TO THE VALUES SHOWN ON PLANS; BASIS-OF- DESIGN IS ALDES CAR3. B. GUEST ROOM HEATING AND COOLING PTAC UNITS SHALL BE PROVIDED TO MEET WSEC C403.7.4.1 WITH CONTROLS CONFIGURED TO AUTOMATICALLY RAISE THE SET POINTS. C. REMOTE, WALL-MOUNTED, HARD-WIRED, ELECTRONIC DIGITAL THERMOSTAT SPECIFICALLY DESIGNED FOR GUEST SUITE APPLICATIONS MUST BE PROVIDED. STUDIO SUITES AND MULTI- ROOM SUITES, SERVED BY A SINGLE HVAC UNIT, MUST HAVE THE THERMOSTAT LOCATED IN THE MAIN SLEEPING AREA. GUEST ROOMS SERVED BY MULTIPLE HVAC UNITS MUST HAVE A THERMOSTAT FOR EACH HVAC UNIT LOCATED IN THE SPACE SERVED BY THAT UNIT. BATTERY POWERED THERMOSTATS ARE NOT ACCEPTABLE. D. DUCTWORK DIRECTLY SERVING THE POOL AND POOL MEP ROOMS SHALL BE CONSTRUCTED OF ALUMINUM. E. DUCTS SHALL BE CONSTRUCTED OF MINIMUM 26-GUAGE STEEL. DUCT PENETRATIONS THROUGH 1-HR (OR LESS) RATED FIRE PARTITIONS IN GUEST CORRIDOR DO NOT REQUIRE FIRE DAMPERS PER IBC 717.5.4 EXCEPTION 4. www.coffman.com 221 N. Wall Street, Suite 500 Spokane, WA 99201 ph 509.328.2994 32 MERCHANT STREET, SUITE 208 HONOLULU, HI 96813 808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 992163RD FLOOR MECHANICAL PLAN M-103 FSC PROJECT NO. 21012 PERMIT SET MAY 30, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce Lane Spokane, WA 99206 (509) 919-0901 3/32" = 1'-0" 3RD FLOOR MECHANICAL PLAN 0'6'12'24' SCALE: 3/32" = 1'-0" Revision Schedule Number Description Date 5/30/2024 MMM M M M M M MM M M M M M M M M M MMMMMMMMMM MMMMMM MMMMMMMMMMMMMMMMMMMMMMMMMMMMMA AA A A AA A AA A A A A A A A A A A AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAM A A A B B C C D C.1 E E F F G G H H J J K K L.1 L.1 M M N N P P Q Q 99 8.1 88 77 6.1 66 55 44 3.13.1 33 2.12.1 1.11.1 2 2 ELEV 2 113 ELEV 1 111 KING STUDIO 437 KING STUDIO ENLARGED 438 DOUBLE QUEEN 436 DOUBLE QUEEN 435 EFFICIENCY 433 KING 1-BEDROOM 402 KING 1-BEDROOM ENLARGED 401 DOUBLE QUEEN 410 KING STUDIO 404 DOUBLE QUEEN ENLARGED 412 KING STUDIO 414 EFFICIENCY 407 PANELS 409A ELEVATOR LOBBY 417 LINENES & HOUSEKEEPING 409 EFFICIENCY ADA-M-RI 403 CONNECTING CORRIDOR 400 ? ? EFFICIENCY 429 EFFICIENCY 427 EFFICIENCY 408 EFFICIENCY 405 KING STUDIO 420 KING STUDIO 418 KING STUDIO 416 KING STUDIO 426 KING STUDIO 419 KING STUDIO 421 KING STUDIO 423 KING STUDIO 425 DOUBLE QUEEN 424 DOUBLE QUEEN 422 GUEST CORRIDOR 415 EFFICIENCY 428 EFFICIENCY 431 EFFICIENCY 434 KING STUDIO 430 STAIR 2 432 STAIR 1 406 IDF 409B M-401 6 1S 25 1E 25 1E 55 2S 80 16x8 12x810ø 4ø 4ø 6ø8ø 10ø12ø 10ø 8ø 6ø 4ø 4ø4ø4ø 4R 300 10ø 8ø 1S 50 6S 300 2S 50 26x104ø 4ø 6ø 4ø 16x8 16x8 12x8 FSD-41 FSD-42 FCU-341 EH-41 FCU-342 FCU-343 FCU-344 FCU-345 EH-42 4ø GENERAL NOTES A. MOTORIZED DAMPERS SHALL BE PROVIDED TO EACH GUEST ROOM PER WSEC C403.7.4.2 TO SERVE AS ISOLATION DEVICES CAPABLE OF AUTOMATICALLY SHUTTING OFF THE SUPPLY OF OUTDOOR AIR TO AND EXHAUST AIR FROM EACH GUEST ROOM. CONSTANT VOLUME DAMPER SHALL BE INSTALLED IN DUCT BRANCHES SERVING GUEST ROOMS, SET TO AUTOMATICALLY CONTROL AIRFLOW TO THE VALUES SHOWN ON PLANS; BASIS-OF- DESIGN IS ALDES CAR3. B. GUEST ROOM HEATING AND COOLING PTAC UNITS SHALL BE PROVIDED TO MEET WSEC C403.7.4.1 WITH CONTROLS CONFIGURED TO AUTOMATICALLY RAISE THE SET POINTS. C. REMOTE, WALL-MOUNTED, HARD-WIRED, ELECTRONIC DIGITAL THERMOSTAT SPECIFICALLY DESIGNED FOR GUEST SUITE APPLICATIONS MUST BE PROVIDED. STUDIO SUITES AND MULTI- ROOM SUITES, SERVED BY A SINGLE HVAC UNIT, MUST HAVE THE THERMOSTAT LOCATED IN THE MAIN SLEEPING AREA. GUEST ROOMS SERVED BY MULTIPLE HVAC UNITS MUST HAVE A THERMOSTAT FOR EACH HVAC UNIT LOCATED IN THE SPACE SERVED BY THAT UNIT. BATTERY POWERED THERMOSTATS ARE NOT ACCEPTABLE. D. DUCTWORK DIRECTLY SERVING THE POOL AND POOL MEP ROOMS SHALL BE CONSTRUCTED OF ALUMINUM. E. DUCTS SHALL BE CONSTRUCTED OF MINIMUM 26-GUAGE STEEL. DUCT PENETRATIONS THROUGH 1-HR (OR LESS) RATED FIRE PARTITIONS IN GUEST CORRIDOR DO NOT REQUIRE FIRE DAMPERS PER IBC 717.5.4 EXCEPTION 4. www.coffman.com 221 N. Wall Street, Suite 500 Spokane, WA 99201 ph 509.328.2994 32 MERCHANT STREET, SUITE 208 HONOLULU, HI 96813 808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 992164TH FLOOR MECHANICAL PLAN M-104 FSC PROJECT NO. 21012 PERMIT SET MAY 30, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce Lane Spokane, WA 99206 (509) 919-0901 3/32" = 1'-0" 4TH FLOOR MECHANICAL PLAN 0'6'12'24' SCALE: 3/32" = 1'-0" Revision Schedule Number Description Date 5/30/2024 MMM M M M M M MM M M M M M M M M M MMMMMMMMMM MMMMMM MMMMMMMMMMMMMMMMMMMMMMMMMMMMMAA A A AA A AA A A A A A A A A A A AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAM A A A B B C C D C.1 E E F F G G H H J J K K L.1 L.1 M M N N P P Q Q 99 8.1 88 77 6.1 66 55 44 3.13.1 33 2.1 1.11.1 2 ELEV 2 113 ELEV 1 111 KING STUDIO 537 KING STUDIO ENLARGED 538 DOUBLE QUEEN 536 DOUBLE QUEEN 535 EFFICIENCY 533 KING 1-BEDROOM 502 KING 1-BEDROOM ENLARGED 501 DOUBLE QUEEN 510 KING STUDIO 504 DOUBLE QUEEN ADA-M-T 512 KING STUDIO 514 EFFICIENCY 507 ELEVATOR LOBBY 517 LINENES & HOUSEKEEPING 509 EFFICIENCY ADA-M-T 503 CONNECTING CORRIDOR 500 ? ? EFFICIENCY 529 EFFICIENCY 527 EFFICIENCY 508 EFFICIENCY 505 KING STUDIO 520 KING STUDIO 518 KING STUDIO 516 KING STUDIO 526 KING STUDIO 519 KING STUDIO 521 KING STUDIO 523 KING STUDIO 525 DOUBLE QUEEN 524 DOUBLE QUEEN 522 GUEST CORRIDOR 515 EFFICIENCY 528 EFFICIENCY 531 EFFICIENCY 534 KING STUDIO 530 STAIR 1 506 1S 25 1E 25 1E 55 2S 80 16x8 12x810ø 4ø 4ø 6ø8ø 10ø12ø 10ø 8ø 6ø 4ø 4ø4R 300 10ø 8ø 1S 50 6S 300 2S 50 26x104ø 4ø 6ø 4ø 16x8 16x8 12x8 FSD-51 FSD-52 FCU-351 FCU-352 FCU-353 FCU-354 FCU-355 4ø4ø4ø STAIR 2 532 EH-51 EH-52 GENERAL NOTES A. MOTORIZED DAMPERS SHALL BE PROVIDED TO EACH GUEST ROOM PER WSEC C403.7.4.2 TO SERVE AS ISOLATION DEVICES CAPABLE OF AUTOMATICALLY SHUTTING OFF THE SUPPLY OF OUTDOOR AIR TO AND EXHAUST AIR FROM EACH GUEST ROOM. CONSTANT VOLUME DAMPER SHALL BE INSTALLED IN DUCT BRANCHES SERVING GUEST ROOMS, SET TO AUTOMATICALLY CONTROL AIRFLOW TO THE VALUES SHOWN ON PLANS; BASIS-OF- DESIGN IS ALDES CAR3. B. GUEST ROOM HEATING AND COOLING PTAC UNITS SHALL BE PROVIDED TO MEET WSEC C403.7.4.1 WITH CONTROLS CONFIGURED TO AUTOMATICALLY RAISE THE SET POINTS. C. REMOTE, WALL-MOUNTED, HARD-WIRED, ELECTRONIC DIGITAL THERMOSTAT SPECIFICALLY DESIGNED FOR GUEST SUITE APPLICATIONS MUST BE PROVIDED. STUDIO SUITES AND MULTI- ROOM SUITES, SERVED BY A SINGLE HVAC UNIT, MUST HAVE THE THERMOSTAT LOCATED IN THE MAIN SLEEPING AREA. GUEST ROOMS SERVED BY MULTIPLE HVAC UNITS MUST HAVE A THERMOSTAT FOR EACH HVAC UNIT LOCATED IN THE SPACE SERVED BY THAT UNIT. BATTERY POWERED THERMOSTATS ARE NOT ACCEPTABLE. D. DUCTWORK DIRECTLY SERVING THE POOL AND POOL MEP ROOMS SHALL BE CONSTRUCTED OF ALUMINUM. E. DUCTS SHALL BE CONSTRUCTED OF MINIMUM 26-GUAGE STEEL. DUCT PENETRATIONS THROUGH 1-HR (OR LESS) RATED FIRE PARTITIONS IN GUEST CORRIDOR DO NOT REQUIRE FIRE DAMPERS PER IBC 717.5.4 EXCEPTION 4. www.coffman.com 221 N. Wall Street, Suite 500 Spokane, WA 99201 ph 509.328.2994 32 MERCHANT STREET, SUITE 208 HONOLULU, HI 96813 808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 992165TH FLOOR MECHANICAL PLAN M-105 FSC PROJECT NO. 21012 PERMIT SET MAY 30, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce Lane Spokane, WA 99206 (509) 919-0901 3/32" = 1'-0" 5TH FLOOR MECHANICAL PLAN 0'6'12'24' SCALE: 3/32" = 1'-0" Revision Schedule Number Description Date 5/30/2024 A A B B C C D C.1 C.1 E E F F G G H H J J K K L.1 L.1 M M N N P P Q Q 99 8.1 88 77 6.1 66 55 44 3.13.1 33 2.12.1 1.11.1 2 2 ERV-01 30x30 30x30 CU-02 CONDENSING UNIT FOR VRF SYSTEM SERVING THE GROUND FLOOR RL/RS DN LINEN CHUTE VENT PROVIDED BY VENDOR CONDENSING UNIT FOR THE ELEVATOR MACHINE SPACE CU-05 CU-03 CU-04 11 1 2 3 1 GENERAL NOTES A. LOCATE PLUMBING VENTS AND EXHAUST FANS/STACKS 25'-0" MIN. FROM HVAC AIR INTAKES, AS SHOWN WITH DASHED CIRCLES ON PLAN. B. LOCATE ALL SERVICABLE EQUIPMENT A MINIMUM OF 10'-0" AWAY FROM BUILDING EDGE. www.coffman.com 221 N. Wall Street, Suite 500 Spokane, WA 99201 ph 509.328.2994 32 MERCHANT STREET, SUITE 208 HONOLULU, HI 96813 808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 99216MECHANICAL ROOF PLAN M-106 FSC PROJECT NO. 21012 PERMIT SET MAY 30, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce Lane Spokane, WA 99206 (509) 919-0901 3/32" = 1'-0" MECHANICAL ROOF PLAN 0'6'12'24' SCALE: 3/32" = 1'-0" KEY NOTES 1 SECURE CONDENSING UNITS TO STANDS THAT ELEVATE UNITS A MINIMUM OF 18" ABOVE ROOF LEVEL FOR SNOW CLEARANCE. 2 ERV-01 TO BE PROVIDED WITH A SIDE CONNECTION CURB. SUPPLY AND EXHAUST DUCTS TO CONNECT TO CURB. 3 PROVIDE A WATER TIGHT CONNECTION AROUND DUCTS AT ROOF PENETRATIONS. Revision Schedule Number Description Date 5/30/2024 MAAMMMAAM M A A M M A A M M A A M M A A K 7 6 EFFICIENCY 129 PTAC-01 1S 30 1E 35 4ø4øN P 7 6 DOUBLE QUEEN 135 PTAC-01 1S 50 4ø1E 55 C D C.1 3 2.1 2 EFFICIENCY ENLARGED 203 PTAC-01 1S 30 1E 35 4ø 4øA B 8.1 8 7 6.1 DOUBLE QUEEN ENLARGED 212 PTAC-01 1S 50 1E 55 4ø4ø C D C.1 3 2.1 2 EFFICIENCY ENLARGED 303 PTAC-01 4ø 4ø 1E 35 1S 30 DOUBLE QUEEN ENLARGED 412 PTAC-01 A A B B 6.1 6.1 7 7 8 8 8.1 8.1 4ø4ø 1E 55 1S 50 GENERAL NOTES A. MOTORIZED DAMPERS SHALL BE PROVIDED TO EACH GUEST ROOM PER WSEC C403.7.4.2 TO SERVE AS ISOLATION DEVICES CAPABLE OF AUTOMATICALLY SHUTTING OFF THE SUPPLY OF OUTDOOR AIR TO AND EXHAUST AIR FROM EACH GUEST ROOM. CONSTANT VOLUME DAMPER SHALL BE INSTALLED IN DUCT BRANCHES SERVING GUEST ROOMS, SET TO AUTOMATICALLY CONTROL AIRFLOW TO THE VALUES SHOWN ON PLANS; BASIS-OF- DESIGN IS ALDES CAR3. B. GUEST ROOM HEATING AND COOLING PTAC UNITS SHALL BE PROVIDED TO MEET WSEC C403.7.4.1 WITH CONTROLS CONFIGURED TO AUTOMATICALLY RAISE THE SET POINTS. C. REMOTE, WALL-MOUNTED, HARD-WIRED, ELECTRONIC DIGITAL THERMOSTAT SPECIFICALLY DESIGNED FOR GUEST SUITE APPLICATIONS MUST BE PROVIDED. STUDIO SUITES AND MULTI- ROOM SUITES, SERVED BY A SINGLE HVAC UNIT, MUST HAVE THE THERMOSTAT LOCATED IN THE MAIN SLEEPING AREA. GUEST ROOMS SERVED BY MULTIPLE HVAC UNITS MUST HAVE A THERMOSTAT FOR EACH HVAC UNIT LOCATED IN THE SPACE SERVED BY THAT UNIT. BATTERY POWERED THERMOSTATS ARE NOT ACCEPTABLE. D. DUCTWORK DIRECTLY SERVING THE POOL AND POOL MEP ROOMS SHALL BE CONSTRUCTED OF ALUMINUM. E. DUCTS SHALL BE CONSTRUCTED OF MINIMUM 26-GUAGE STEEL. DUCT PENETRATIONS THROUGH 1-HR (OR LESS) RATED FIRE PARTITIONS IN GUEST CORRIDOR DO NOT REQUIRE FIRE DAMPERS PER IBC 717.5.4 EXCEPTION 4. www.coffman.com 221 N. Wall Street, Suite 500 Spokane, WA 99201 ph 509.328.2994 32 MERCHANT STREET, SUITE 208 HONOLULU, HI 96813 808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 99216ENLARGED MECHANICAL PLANS M-401 FSC PROJECT NO. 21012 PERMIT SET MAY 30, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce Lane Spokane, WA 99206 (509) 919-0901 1/4" = 1'-0"1 ENLARGED PLAN - EFFICIENCY 1/4" = 1'-0"4 ENLARGED PLAN - DOUBLE QUEEN 1/4" = 1'-0"3 ENLARGED PLAN - EFFICIENCY ADA-M-RI 1/4" = 1'-0"5 ENLARGED PLAN - DOUBLE QUEEN ENLARGED 1/4" = 1'-0"2 ENLARGED PLAN - EFFICIENCY ENLARGED 1/4" = 1'-0"6 ENLARGED PLAN - DOUBLE QUEEN ADA-M-T Revision Schedule Number Description Date 5/30/2024 M A A M M A A M M A A MMMAAMMAA 2.1 1.1 2 KING 1-BEDROOM 202 1E 55 1S 25 1S 25 PTAC-01 PTAC-01 4ø 4ø4ø 4ø DC.1 1.1 2 KING 1-BEDROOM ENLARGED 201 PTAC-01 PTAC-01 1S 25 1S 30 1E 604ø 4ø 4ø 4ø C DC.1 1.1 2 KING 1-BEDROOM ADA-M-T 301 PTAC-01 PTAC-01 1S 304ø 4ø4ø 4ø1S 25 1E 60 K L.1 9 8 KING STUDIO 130 PTAC-01 1S 35 1E 40 4ø4øP 9 8 KING STUDIO ADA-M-T 138 PTAC-01 1E 40 1S 35 4ø4øGENERAL NOTES A. MOTORIZED DAMPERS SHALL BE PROVIDED TO EACH GUEST ROOM PER WSEC C403.7.4.2 TO SERVE AS ISOLATION DEVICES CAPABLE OF AUTOMATICALLY SHUTTING OFF THE SUPPLY OF OUTDOOR AIR TO AND EXHAUST AIR FROM EACH GUEST ROOM. CONSTANT VOLUME DAMPER SHALL BE INSTALLED IN DUCT BRANCHES SERVING GUEST ROOMS, SET TO AUTOMATICALLY CONTROL AIRFLOW TO THE VALUES SHOWN ON PLANS; BASIS-OF- DESIGN IS ALDES CAR3. B. GUEST ROOM HEATING AND COOLING PTAC UNITS SHALL BE PROVIDED TO MEET WSEC C403.7.4.1 WITH CONTROLS CONFIGURED TO AUTOMATICALLY RAISE THE SET POINTS. C. REMOTE, WALL-MOUNTED, HARD-WIRED, ELECTRONIC DIGITAL THERMOSTAT SPECIFICALLY DESIGNED FOR GUEST SUITE APPLICATIONS MUST BE PROVIDED. STUDIO SUITES AND MULTI- ROOM SUITES, SERVED BY A SINGLE HVAC UNIT, MUST HAVE THE THERMOSTAT LOCATED IN THE MAIN SLEEPING AREA. GUEST ROOMS SERVED BY MULTIPLE HVAC UNITS MUST HAVE A THERMOSTAT FOR EACH HVAC UNIT LOCATED IN THE SPACE SERVED BY THAT UNIT. BATTERY POWERED THERMOSTATS ARE NOT ACCEPTABLE. D. DUCTWORK DIRECTLY SERVING THE POOL AND POOL MEP ROOMS SHALL BE CONSTRUCTED OF ALUMINUM. E. DUCTS SHALL BE CONSTRUCTED OF MINIMUM 26-GUAGE STEEL. DUCT PENETRATIONS THROUGH 1-HR (OR LESS) RATED FIRE PARTITIONS IN GUEST CORRIDOR DO NOT REQUIRE FIRE DAMPERS PER IBC 717.5.4 EXCEPTION 4. www.coffman.com 221 N. Wall Street, Suite 500 Spokane, WA 99201 ph 509.328.2994 32 MERCHANT STREET, SUITE 208 HONOLULU, HI 96813 808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 99216ENLARGED MECHANICAL PLANS M-402 FSC PROJECT NO. 21012 PERMIT SET MAY 30, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce Lane Spokane, WA 99206 (509) 919-0901 1/4" = 1'-0"3 ENLARGED PLAN - KING STUDIO 1 BEDROOM 1/4" = 1'-0"4 ENLARGED PLAN - KING 1 BEDROOM ENLARGED 1/4" = 1'-0"5 ENLARGED PLAN - KING 1 BEDROOM ADA-M-T 1/4" = 1'-0"1 ENLARGED PLAN - KING STUDIO 1/4" = 1'-0"2 ENLARGED PLAN - KING STUDIO ADA-M-T Revision Schedule Number Description Date 5/30/2024 CHANGE OF DUCT SIZE TRANSITION BRANCH DUCT TAKEOFFS END TAP A ≤ 15° FOR DUCTS W/ AIR VELOCITY OVER 1,500 FPM. A ≤ 30° FOR DUCTS W/ AIR VELOCITY UNDER 1,500 FPM RECTANGULAR DUCT DUCT ELBOWS NOTE: OFFSETS (TO AVOID OBSTRUCTIONS) ARE REQUIRED BUT ARE NOT NECESSARILY SHOWN ON THE PLANS. OFFSETS TURNING VANES R=1/2W FOR DUCTS W/ AIR VELOCITY UNDER 1,500 FPM R=W FOR DUCTS W/ AIR VELOCITY OVER 1,500 FPM AND ALL DUCTS UPSTREAM OF TERMINAL UNITS 45° OR 90° RADIUS ELBOWS45.00°ROUND OR RECTANGULAR CONICAL SPIN-IN ROUND DUCT RUNOUT TO SINGLE DIFFUSER OR GRILLE ONLY45.00°DW D=1/2W, BUT NOT MORE THAN 12" (1/3W PERMITTED IF AIR VELOCITY UNDER 3,000 FPM)ACONICAL SPIN-IN OR TRANSITION TO AT LEAST 70% GREATER THAN AREA OF SMALLER DUCT. SEE MAX TRANSITION ANGLE. THE DUCT FITTINGS ABOVE ARE CONSIDERED ACCEPTABLE. THE CONTRACTOR SHALL OBTAIN ENGINEER'S APPROVAL FOR ALTERNATIVE FITTINGS PRIOR TO FABRICATION. ONLY FITTINGS WITH EQUAL OR LOWER PRESSURE DROP WILL BE CONSIDERED.AW12"x12" ACCESS PANEL ON BOTTOM OF DUCT UPSTREAM OF TURNING VANES, REQUIRED FOR RETURN AND EXHAUST DUCTS (ONLY PERMITTED FOR AIR VELOCITY UNDER 1,500 FPM) A ≤ 15° FOR DUCTS W/ AIR VELOCITY OVER 1,500 FPM. A ≤ 30° FOR DUCTS W/ AIR VELOCITY UNDER 1,500 FPM R AW R R=1/2W FOR DUCTS W/ AIR VELOCITY UNDER 1,500 FPM R=W FOR DUCTS W/ AIR VELOCITY OVER 1,500 FPM AND ALL DUCTS UPSTREAM OF TERMINAL UNITS DUCT SUPPORT, MIRO INDUSTRIES 6DS, OR APPROVED EQUAL SET SUPPORT ON EXTRA LAYER OF ROOFING MEMBRANE INSULATE DUCTWORK AS SPECIFIED ROOFTOP DUCTWORK PER PLANS PROVIDE SHEET METAL COVER, AND SEAL WATER TIGHT. PROVIDE SEAMS ON BOTTOM AND SIDES AS MUCH AS FEASIBLE UNISTRUT SUPPORT ABOVE AND BELOW DUCTWORK NOTE: SPACING NOT TO EXCEED 8' O.C. DUCT SIZE, SEE PLANS FLEXIBLE DUCT CONNECTOR, TYP. DUCT SUPPLY FAN COIL LIQUID SUCTION SEE FLOOR PLANS FOR ROUTING SUPPORT FROM STRUCTUREDOUBLE DEFLECTION SPRING NEOPRENE HANGER, MASON MODEL 30N, OR APPROVED EQUAL FABRICATED FILTER BOX, SIDE ACCESS RETURN DUCT 1" PUMPED CONDENSATE FROM FAN COIL 1" GRAVITY DRAIN CONDENSATE OUTSIDE AIR DUCT RIGID INSULATIONROOF DECK DUCTROOFING CANT STRIP WOOD CURB 22 GA. FLASHING COUNTERFLASHING WEATHERSTRIP WEATHERSEAL ALL JOINTS AND SEAMS NOTES: 1. LENGTH OF LEGS FOR DUCT SUPPORT FRAME VARIES WITH SLOPE OF THE ROOF. DUCT SHALL BE LEVEL. 2. LOCATION OF DUCT SUPPORT FRAME SHALL BE IN ACCORDANCE WITH DIVISION 15. SECURE DUCT TO SUPPORT 2X1X1/8 CHANNEL CROSS MEMBER WELDED TO BOTH LEGS TO SUPPORT DUCT. 2X1X1/8 CHANNEL LEG WELD TO PLATE (TYP. OF 2, ONE ON EACH SIDE) 6X6X3/8 STEEL PLATE FASTENED TO BASEROOF 2x8 WOOD BASE, LENGTH 4" LONGER THAN SUPPORT WIDTH, SET ON WALKING PAD OR REINFORCED ROOFING, DO NOT SECURE 2500 1320 420ONE 1 x 18 GA STRAP36 ONE 1 x 16 GA STRAP 84 60 50 700 ONE 1 x 22 GA STRAP QUANTITY/SIZE IN.MAX. DUCT Ø IN. 26 HANGER STRAPS OR RODS MAX. LOAD LBS. 260 MAX. SPACING IN. 144 144 NOTE: TABULATED DATA FROM SMACNA ALLOWS FOR DUCT REINFORCING AND INSULATION, BUT NO EXTERNAL LOAD.BAND OF SAME SIZE AS HANGER STRAP LOAD RATED FASTENERS 50" Ø & UNDER 144 144 144 TWO 3/8 Ø RODS TWO 1/2 Ø RODS 18 GAUGE SHEET METAL COLLAR FLANGE TIGHT AGAINST WALL SURFACE. ATTACH TO DUCT WITH SHEET METAL SCREWS OR POP RIVETS PARTITION WALL WALLBOARD STUD FRAME OPENING NOT BY MECHANICAL SHEET METAL DUCT NAILER STRIP NEOPRENE GASKET COUNTER FLASHING NOTE: ATTACH EQUIPMENT TO CURB PER MFR'S INSTALLATION INSTRUCTIONS. SEE S-501 FOR CURB TO STRUCTURE ATTACHMENT DETAIL. SEE ARCHITECTURAL DETAILS FOR ROOFING SCOPE. PACKAGED ROOFTOP AIR CONDITIONING UNIT VIBRATION ISOLATION SPRINGS INCLUDED WITH EQUIPMENT CURB ROOF CURB UNIT SIDE DUCT CONNECTION, TYP. FLEXIBLE DUCT CONNECTION, TYP. SUPPLY/ RETURN AIR NOTE: CONTRACTOR SHALL PROVIDE A DEFERRED SUBMITTAL DETAILING ANCHORAGE OF UNIT TO CURB AND CURB TO STRUCTURE. CALCULATIONS AND DETAILS SHALL BE STAMPED BY A STRUCTURAL ENGINEER LICENSED IN THE STATE OF WASHINGTON. SECURE EQUIPMENT TO STRUCTURE WITH 8 GAUGE WIRE. FASTEN WITH 3 TIGHT TURNS IN 1". WIRE MAY BE SLACK. TYP. ALL FOUR SIDES. LOUVERED GRILLE WITH SURFACE MOUNT FRAME SPIN-IN CONNECTION SEALANT SHEET METAL BOOT, SEALANT ON ALL SEAMS TOP INLET, WHERE APPLICABLE CONNECT SPIN-IN AS CLOSE AS POSSIBLE TO TOP OF PLENUM S.S. OR NYLON CLAMP FLEXIBLE DUCT SIZE AS INDICATED ON PLANS SIDE INLET, WHERE APPLICABLE NOTE: BOOT HEIGHT SHALL BE MIN. 8", WIDTH AND LENGTH SHALL MATCH GRILLE FLANGE. LAY-IN CEILING SECURE EQUIPMENT TO STRUCTURE WITH 8 GAUGE WIRE. FASTEN WITH 3 TIGHT TURNS IN 1". WIRE MAY BE SLACK. TYP. ALL FOUR SIDES. LOUVERED GRILLE WITH LAY-IN FRAMESPIN-IN CONNECTION SEALANT SHEET METAL BOOT, SEALANT ON ALL SEAMS TOP INLET, WHERE APPLICABLE CONNECT SPIN-IN AS CLOSE AS POSSIBLE TO TOP OF PLENUM S.S. OR NYLON CLAMP FLEXIBLE DUCT SIZE AS INDICATED ON PLANS SIDE INLET, WHERE APPLICABLE NOTE: BOOT HEIGHT SHALL BE MIN. 8", WIDTH AND LENGTH SHALL MATCH GRILLE FLANGE. GYP. BD. SECURE EQUIPMENT TO STRUCTURE WITH 12 GA. WIRE. FASTEN WITH 3 TIGHT TURNS IN 1" WIRE MAY BE SLACK. TYPICAL ALL FOUR SIDES. TRANSITION, WHERE REQ'D SUPPLY DIFFUSER S.S. OR NYLON CLAMP FLEXIBLE DUCT CEILING R=1.5xø PROVIDE SMOOTH RADIUS CONNECTION, PROPERLY SUPPORT FLEX DUCT FOR SMOOTH AIR FLOW TO DIFFUSER SHEETMETAL DUCT MAX SAG 1/2" PER FOOT ON SUPPORT SPACING FLEXIBLE INSULATED NONMETALLIC DUCT, SIZE AS INDICATED ON PLANS SEE SPECS 1" WIDE SHEET METAL STRAP SECURED TO STRUCTURE, SIZE AND SPACING PER MECHANICAL CODE www.coffman.com 221 N. Wall Street, Suite 500 Spokane, WA 99201 ph 509.328.2994 32 MERCHANT STREET, SUITE 208 HONOLULU, HI 96813 808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 99216MECHANICAL DETAILS M-501 FSC PROJECT NO. 21012 PERMIT SET MAY 30, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce Lane Spokane, WA 99206 (509) 919-0901 NTS1LOW PRESSURE DUCT FITTING REQUIREMENTS NTS2OUTDOOR DUCT DETAIL - STAND NTS5HORIZONTAL FAN COIL INSTALLATION - DUCTED RETURN NTS7ROOF DUCT PENETRATION NTS3OUTSIDE AIR DUCT SUPPORT DETAIL NTS6ROUND DUCT HANGER NTS4STUD WALL PENETRATION NTS8ENERGY RECOVERY UNIT MOUNTING NTS9TYP. RETURN/EXHAUST GRILLE MOUNTING NTS10SUPPLY DIFFUSER INSTALLATION Revision Schedule Number Description Date 5/30/2024 CONDENSING UNIT SECURE CONDENSING UNIT TO STAND PER MANUFACTURER'S INSTRUCTIONS, TYP. OF 4 MANUFACTURER OUTDOOR UNIT STAND ROOF FLASHING, SEE ARCHITECTURAL ANCHOR BOLTS, TYP. OF 4 EACH LEG ROOF, SEE ARCHITECTURAL CONDENSING UNIT BEAM RIGID INSULATION SPRING ASSEMBLY, MASON INDUSTRIES SLRSO-B-750. ONE AT EACH CORNER, TYP. OF 4. LAG TO CURB WATER TIGHT, USE RUBBER GROMMETS AND SEALANT UNIT BASE RAIL 3/4" PLYWOOD 6" RIGID INSULATION PER ARCH. METAL ROOF DECK INTERPLY ROOFING MEMBRANE SEAMLESS SHEET METAL FLASHING/COVER 2x2x3/16" W/ (2) #10 TEK SCREWS @ 3" O.C. INTO DECK & (2) #10 TEK SCREWS @ 3" O.C. INTO WOOD PLATFORM, TYP. EA. CORNER OF UNIT TREATED WOOD CURBING, 3" MIN. WIDTH 1 2 KEYNOTES: 1. CONSTRUCT CURB ON ALL 4 SIDES. FIELD VERIFY NECCESSARY WOOD HEIGHT TO MAINTAIN 8" MIN. CURB HEIGHT ABOVE ROOF INSULATION. 2. 2x6 AT 3'-0" O.C. MAX, EVENLY SPACED, PERPENDICULAR TO LONG SIDE. SUPPORT W/ SIMPSON LU HANGER AT EACH END. VIBRO-ACOUSTICS IFB STEEL BASE, SIZE TO MATCH CONDENSING UNIT BOLT UNIT TO BASE PER MRF'S RECOMMENDATIONS www.coffman.com 221 N. Wall Street, Suite 500 Spokane, WA 99201 ph 509.328.2994 32 MERCHANT STREET, SUITE 208 HONOLULU, HI 96813 808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 99216MECHANICAL DETAILS M-502 FSC PROJECT NO. 21012 PERMIT SET MAY 30, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce Lane Spokane, WA 99206 (509) 919-0901 NTS1CONDENSING UNIT MOUNTING, OUTDOOR COMPONENT - AC UNITS NTS2CONDENSING UNIT MOUNTING Revision Schedule Number Description Date 5/30/2024 M M DO OUTSIDE AIR EXHAUST AIR OPEN/CLOSE SMART THERMOSTAT (HONEYWELL INNCOM)PTAC HILTON EDGE SYSEM DI AI RENTAL STATUS SETPOINT S S S OCCUPANCY SENSOR PATIO DOOR SENSOR DOOR SENSOR DO AO ENABLE/DISABLE SETPOINT 24V WIRING BY CONTROLS CONTRACTOR, TYP. PTAC DO AO ENABLE/DISABLE SETPOINT T ADDITIONAL OCCUPANCY SENSOR IN SPECIFIED ROOMS ONLY (SEE PLANS) PATIO DOOR IN SPECIFIED ROOMS ONLY (SEE PLANS) ADDITIONAL PTAC IN SPECIFIED ROOMS ONLY (SEE PLANS) ROOM LIGHTS (SEE ELECTRICAL) SEQUENCE OF OPERATION: HILTON EDGE SYSTEM SHALL DETERMINE ROOM RENTAL STATUS, SMART THERMOSTAT SHALL DETECT ROOM OCCUPANCY VIA BUILT-IN OCCUPANCY SENSORS AND GUESTROOM DOOR SIGNAL. PTAC SHALL MODULATE TO MEET SETPOINT USING FACTORY CONTROLS. UNRENTED, UNOCCUPIED MODE: 1. VENTILATION DAMPERS SHALL BE NORMALLY CLOSED. ONCE DAILY, DAMPERS SHALL OPEN FOR 60 MINUTES. 2. PTAC SETPOINTS SHALL RESET TO: COOLING: 80°F (MIN.) HEATING: 60°F (MAX.) RENTED, OCCUPIED MODE: 1. VENTILATION DAMPERS SHALL BE OPEN TO PROVIDE OUTSIDE AIR AND EXHAUST. 2. PTAC SETPOINT SHALL RETURN TO OCCUPANT SETPOINT ANDL BE ADJUSTABLE BY THE GUEST. DEFAULT VALUES ARE: COOLING: 75°F (MIN.) HEATING: 70°F (MAX.) RENTED, UNOCCUPIED MODE: 1. WITHIN 20 MINUTES OF OCCUPANTS LEAVING THE GUESTROOM, VENTILATION DAMPERS SHALL CLOSE . 2. WITHIN 30 MINUTES OF OCCUPANTS LEAVING THE GUESTROOM, PTAC SETPOINTS SHALL RESET TO: COOLING: OCCUPANT SETPOINT +4°F (MIN.) HEATING: OCCUPANT SETPOINT -4°F (MAX.) PTAC SHALL BE DISABLED WHEN PATIO DOOR IS OPEN IF SENSOR HAS DETECTED DOOR OPEN FOR LONGER THAN 20 SECONDS. PTAC SHALL ENABLE AFTER SENSOR DETECTS DOOR CLOSED FOR LONGER THAN 20 SECONDS, AO SETPOINT DO ENABLE/DISABLE DI STATUS HEAT EXCHANGER AO SETPOINT DO ENABLE/DISABLE DI STATUS DI DP DI DPT AI FILTER STATUS OUTSIDE AIR TEMP H C AO GAS FURNACE SUPPLY AIR TEMP T AI SUPPLY AIR EXHAUST AIR PAIDUCT STATIC P AI DUCT STATIC EXHAUST AIR OUTSIDE AIR FIRE/SMOKE DAMPER, TYP. DUCT STATIC PRESSURE SENSORS LOCATED ACCORDING TO HVAC PLAN SEQUENCE OF OPERATION: SYSTEM SUPPLIES OUTSIDE AIR TO THE BUILDING AND REMOVES EXHAUST AIR, RECOVERING ENERGY TO PRE-CONDITION THE OUTSIDE AIR. IT SHALL BE ENABLED WHILE THE BUILDING IS OCCUPIED AND OPERATE BASED ON PACKAGED FACTORY CONTROLS. SUPPLY AND EXHAUST FANS SHALL MODULATE TO MAINTAIN STATIC PRESSURE SETPOINT, AS MEASURED BY DUCT STATIC PRESSURE SENSORS. GUEST ROOMS WILL HAVE DEMAND-CONTROLLED VENTILATION, WHERE DAMPERS WILL CLOSE WHEN THE ROOM IS UNOCCUPIED AND RE-OPEN ONCE OCCUPANCY IS DETECTED. MINIMUM SUPPLY TEMPERATURE: INTEGRATED GAS FURNACE SHALL ENABLE TO MAINTAIN SUPPLY AIR TEMPERATURE LEAVING THE UNIT OF 55°F AI SPACE TEMPERATURE OUTDOOR UNIT T SPLIT AIR CONDITIONING UNIT CONTROL DIAGRAM SEQUENCE OF OPERATION: UNIT SHALL OPERATE WITH FACTORY CONTROLS TO MAINTAIN TEMPERATURE SETPOINT AT TOP OF ELEVATOR SHAFT INDOOR UNIT SEQUENCE OF OPERATION: EXHAUST FAN EF-02 SHALL BE INTERLOCKED WITH LV-02 TO PROVIDE CONTINUOUS VENTILATION AND EXHAUST AT THE RATE SHOWN ON THE EQUIPMENT SCHEDULES. WHEN EF-02 IS ENABLED, DAMPER SHALL OPEN AND COMBINATION LOUVER LV-02 SHALL OPEN. WHEN FAN IS DISABLED, DAMPER AND LOUVER SHALL SHUT. UNIT HEATER UH-01 SHALL CYCLE TO MAINTAIN A TEMPERATURE OF 60°F (ADJ). EF-02 M LV-02 OUTSIDE AIR UH-01 ROOM EXHAUST AIR POOL BATHROOM EXHAUST AIR MCU-01 EF-01 M AHU-01 LV-01 MM POOL RETURN AIR POOL SUPPLY AIR DH-01 EXHAUST AIR OUTSIDE AIR CD TO DRAIN RS/RL GAS FLUE VENT POOL WATER (BY POOL CONTRACTOR) SEQUENCE OF OPERATION: AHU-01 SHALL BE SUPPLIED WITH FACTORY CONTROLLER AS INDICATED ON EQUIPMENT SCHEDULES AND IN SPECIFICATIONS. THE FOLLOWING SEQUENCE SHALL BE EXECUTED FROM THAT CONTROLLER. SYSTEM STARTUP: AFTER A SHORT INITIAL DELAY TO ALLOW THE SENSORS TO STABILIZE, THE BLOWER STARTS AND OPERATES CONTINUOUSLY. THE SYSTEM SHALL BEGIN OR RESUME OPERATION BASED ON THE SEQUENCE BELOW: AIRSIDE CONFIGURATION: THE SYSTEM CONTINUOUSLY DELIVERS THE SPECIFIED SUPPLY AIR VOLUME TO THE POOL AREA. THE MINIMUM EXHAUST AIR VOLUME (EF-01 SETPOINT) AND OUTDOOR AIR VOLUME ARE SET TO MEET THE VALUES ON THE EQUIPMENT SCHEDULES. DEHUMIDIFICATION MODE: OCCURS WHEN THE RETURN AIR RELATIVE HUMIDITY IS ABOVE THE HUMIDITY SETPOINT AND RETURN AIR DEWPOINT IS ABOVE DEWPOINT SETPOINT. THE COMPRESSOR ENTERS THE COMPRESSOR START SEQUENCE, AND THE REHEAT OUTPUT WILL ADJUST TO MAINTAIN THE SPACE TEMPERATURE AT SET POINT YEAR-ROUND. COOLING MODE: OCCURS WHEN THE RETURN AIR TEMPERATURE IS ABOVE THE ROOM TEMPERATURE SETPOINT. ECONOMIZER COOLING WILL BE ENABLED. DURING ECONOMIZER COOLING, THE RETURN AIR DAMPER SHALL SHUT AND THE EXHAUST FAN EF-01 SHALL INCREASE TO MAXIMUM SPEED ACCORDING TO THE EQUIPMENT SCHEDULE. ECONOMIZER SHALL BE LOCKED OUT WHEN OUTSIDE AIR TEMPERATURE IS ABOVE 84F (ADJUSTABLE). IF ROOM TEMPERATURE SETPOINT IS NOT ACHIEVED AFTER TEN MINNUTES (ADJUSTABLE), THEN THE COMPRESSOR STARTS AND EXCESS COMPRESSOR HOT GAS IS DIVERTED TO THE OUTDOOR AIR COOLED CONDENSER CU-01 FOR UP TO 100% HEAT REJECTION AT SUMMER DESIGN AMBIENT CONDITIONS SPACE HEATING MODE: OCCURS WHEN THE RETURN AIR TEMPERATURE IS BELOW THE ROOM TEMPERATURE SETPOINT. THE MICROPROCESSOR SPACE HEATING OUTPUT SIGNAL IS SENT TO THE DUCT HEATER DH-01. THE SIGNAL OUTPUT WILL REGULATE BASED ON THE RETURN AIR TEMPERATURE TO MODULATE THE HEATING AT THE DUCT HEATER. POOL WATER HEATING MODE: OCCURS WHEN THE RETURN POOL WATER TEMPERATURE IS BELOW THE POOL WATER SETPOINT AND THE POOL WATER FLOW SWITCH OR MINIMUM TEMPERATURE DIFFERENTIAL IS SATISFIED. IF THE COMPRESSOR IS ALREADY OPERATING DUE TO A DEHUMIDIFICATION OR AIR CONDITIONING DEMAND, THE CONTROL VALVES WILL DIVERT THE COMPRESSOR HOT GAS THROUGH THE COAXIAL HEAT EXCHANGER TO HEAT THE POOL WATER, WITH THE REMAINDER REJECTED AT THE AIR REHEAT COIL OR THE AC HEAT EXCHANGER. AUXLIIARY POOL WATER HEATER WILL BE ENGAGED AS A SECOND STAGE AS NEEDED. IF THERE IS NO PRE-EXISTING DEMAND FOR THE COMPRESSOR TO OPERATE, THE MICROPROCESSOR SENDS A SIGNAL TO THE AUXILIARY POOL WATER HEATER (REMOTE BY OTHERS) TO OPERATE. THE COMPRESSOR WILL NOT OPERATE SOLELY FOR A POOL WATER HEATING DEMAND UNLESS SPECIFICALLY CONFIGURED TO DO SO AT THE CONTROLLER. AUX POOL HEAT CONTACT WILL BE CLOSED WITH INSUFFICIENT FLOW. IN ORDER TO PREVENT THE POOL FROM OVERHEATING, IT IS RECOMMENDED THAT A FIELD-INSTALLED AQUASTAT (PROVIDED BY OTHERS)BE INSTALLED IN SERIES WITH THESE WIRES. FIELD-INSTALLED POOL WATER TEMPERATURE SENSOR(S) ARE PROVIDED TO ENABLE THE SMART POOL FEATURE. THIS FEATURE PROVIDES THE ABILITY TO ACTIVATE BOOSTER POOL WATER PUMP(S) FEEDING THE UNIT WHEN POOL WATER HEATING IS IN DEMAND. FREEZE PROTECTION: OCCURS WHEN THE SUPPLY AIR TEMPERATURE FALLS BELOW THE FREEZESTAT SETPOINT. EXHAUST FAN EF-01 IS STOPPED AND OUTDOOR AIR DAMPER IS FULLY CLOSED. WHEN THE FREEZESTAT ALARM IS TRIPPED, IT MUST BE MANUALLY CLEARED BY THE OPERATOR. www.coffman.com 221 N. Wall Street, Suite 500 Spokane, WA 99201 ph 509.328.2994 32 MERCHANT STREET, SUITE 208 HONOLULU, HI 96813 808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 99216MECHANICAL CONTROL DIAGRAMS M-601 FSC PROJECT NO. 21012 PERMIT SET MAY 30, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce Lane Spokane, WA 99206 (509) 919-0901 NTS1GUEST ROOM CONTROL SYSTEM NTS2DEDICATED OUTSIDE AIR CONTROL SYSTEM (ERV-01) NTS3SPLIT SYSTEM CONTROL DIAGRAM NTS4POOL MEP CONTROL NTS5AHU-01 CONTROL SYSTEM Revision Schedule Number Description Date 5/30/2024 AIR HANDLING UNIT SCHEDULE TAG LOCATION SERVES MANUFACTURER / MODEL SUPPLY FAN COOLING CAPACITY HEATING CAPACITY UNIT ELECTRICAL REQUIREMENTS AIR FILTERS SIZE (WxLxH) UNIT WT. (LBS) REMARKSTOTAL CFM HEATING CFM MIN CFM MIN OA CFM ESP (IN. WC) SENS. (MBH) TOTAL (MBH) TOTAL (MBH)GPM PSI #SIZE (IN)HP DRIVE VOLTS Ø MCA MOCP AHU-01 POOL MEP 103 POOL/SPLASH PAD POOLPAK/ PCP-2600-PS-I 3,100 3,100 1,300 1,155 1 3.2 DIRECT 54.6 101.7 63 12 10 460 3 19 30 2 4" MERV 13 36.25x56.25x61 870 1, 2, 3 MAU-01 FOOD PREP 123 FOOD PREP HOOD CAPTIVEAIRE/ A1-D.500-15D 1,380 1,380 1,000 - 0.5 1 DIRECT 112 - - 208 3 5.1 15 825 4, 5 1.SUPPLY COMMANDPAK UNIT CONTROL SYSTEM. AHU WORKS IN CONJUNCTION WITH DUCT-MOUNTED HEATER IN SUPPLY DUCT AND EXHAUST FAN MOUNTED IN RETURN DUCT. 2.HEATING CAPACITY SHOWN IS FOR HEATING POOL WATER WITH REJECTED HEAT FROM THE UNIT WHEN COOLING/DEHUMIDIFYING. SUPPLY AIR HEATING IS ACHIEVED WITH DUCT HEATER DOWNSTREAM OF AHU. 3.OUTSIDE AIR WILL INCREASE TO MAXIMUM CFM WHEN ECONOMIZER MODE IS ACTIVATED. 4.MAKEUP AIR UNIT INCLUDES EVAPORATIVE MEDIA (2.6 GAL/HR) WITH FREEZE PROTECTION DRAIN KIT, IBT/MUA EVAP INTERLOCK, UNIT-MOUNTED VFD, AND MOTORIZED BACKDRAFT DAMPER. 5.MAKEUP AIR UNIT INCLUDES NATURAL GAS FURNACE. SEE DUCT HEATER SCHEDULE FOR FURNACE INFORMATION. PROVIDE WITH 3/4" GAS STRAINER. ENTIRE MUA SHALL BE MOUNTED ON A SINGLE RAIL FOR CEILING-SUSPENDED INSTALLATION. VRF INDOOR UNIT SCHEDULE TAG MFR / MODEL OUTDOOR UNIT TYPE CFM ESP (IN H20) NOISE (dBA)REFRIGERANT CAPACITY (MBH)FILTERS ELECTICAL WEIGHT (LBS)NOTESTOTAL COOLING SENSIBLE COOLING HEATING BOX MODEL MERV (QTY) SIZE VOLTS PHASE MCA MFS FCU-211 MITSUBISHI/TRANE / TPEFYP030MA145A CU-02 CEILING - CONCEALED (DUCTED)1271 0.6 31-39-43 R410A 25.3 24.2 25.3 FBM2-4-A 13 (2) 14 x 20 x 2 (1) 14 x 14 x 2 208 1 4.25 15 84 1, 2, 3, 4 FCU-212 MITSUBISHI/TRANE / TPEFYP015MA144A CU-02 CEILING - CONCEALED (DUCTED)494 0.6 27-31-34 R410A 12.7 10.5 12.7 FBM2-4-A 13 (2) 14 x 20 x 2 (1) 14 x 14 x 2 208 1 2.88 15 58 1, 2, 3, 4 FCU-213 MITSUBISHI/TRANE / TPEFYP048MA144A CU-02 CEILING - CONCEALED (DUCTED)1306 0.6 35-40-44 R410A 40.5 30.6 40.2 FBM2-4-A 13 (2) 14 x 20 x 2 (1) 14 x 14 x 2 208 1 4.38 15 86 1, 2, 3, 4 FCU-214 MITSUBISHI/TRANE / TPEFYP036MA144A CU-02 CEILING - CONCEALED (DUCTED)1271 0.6 35-39-43 R410A 30.4 26.3 29.8 FBM2-3-A 13 (2) 14 x 20 x 2 208 1 4.25 15 67 1, 2, 3, 4 FCU-215 MITSUBISHI/TRANE / TPEFYP096MH140A CU-02 CEILING - CONCEALED (DUCTED)2966 1 39-42-46 R410A 81.1 65.5 80.4 FBH4-4 13 (2) 14 x 20 x 2 (1) 14 x 14 x 2 208 1 8.2 15 221 1, 2, 3, 4 FCU-216 MITSUBISHI/TRANE / TPEFYP054MA144A CU-02 CEILING - CONCEALED (DUCTED)1413 0.6 34-38-42 R410A 25.3 24.2 25.3 FBM2-4-A 13 (2) 14 x 20 x 2 (1) 14 x 14 x 2 208 1 4.38 15 84 1, 2, 3, 4 FCU-217 MITSUBISHI/TRANE / TPEFYP015MA144A CU-02 CEILING - CONCEALED (DUCTED)494 0.6 27-31-34 R410A 12.7 10.5 12.7 FBM2-4-A 13 (2) 14 x 20 x 2 (1) 14 x 14 x 2 208 1 2.88 15 86 1, 2, 3, 4 FCU-311 MITSUBISHI/TRANE / TPLFYP005FM140A CU-03 CEILING - CASSETTE (4-WAY)280 - 26-28-30 R410A 4.5 4.2 5.1 ---208 1 0.24 15 40 1, 2, 3, 4 FCU-324 MITSUBISHI/TRANE / TPLFYP005FM140A CU-03 CEILING - CASSETTE (4-WAY)280 - 26-28-30 R410A 4.5 4.2 5.1 ---208 1 0.24 15 40 1, 2, 3, 4 FCU-323 MITSUBISHI/TRANE / TPLFYP012FM140A CU-03 CEILING - CASSETTE (4-WAY)335 - 26-30-34 R410A 10.8 7.6 12.4 ---208 1 0.29 15 40 1, 2, 3, 4 FCU-322 MITSUBISHI/TRANE / TPLFYP005FM140A CU-03 CEILING - CASSETTE (4-WAY)280 - 26-28-30 R410A 4.5 4.2 5.1 ---208 1 0.24 15 40 1, 2, 3, 4 FCU-333 MITSUBISHI/TRANE / TPLFYP005FM140A CU-03 CEILING - CASSETTE (4-WAY)280 - 26-28-30 R410A 4.5 4.2 5.1 ---208 1 0.24 15 40 1, 2, 3, 4 FCU-332 MITSUBISHI/TRANE / TPLFYP012FM140A CU-03 CEILING - CASSETTE (4-WAY)335 - 26-30-34 R410A 10.8 7.6 12.4 ---208 1 0.29 15 40 1, 2, 3, 4 FCU-343 MITSUBISHI/TRANE / TPLFYP005FM140A CU-03 CEILING - CASSETTE (4-WAY)280 - 26-28-30 R410A 4.5 4.2 5.1 ---208 1 0.24 15 40 1, 2, 3, 4 FCU-342 MITSUBISHI/TRANE / TPLFYP012FM140A CU-03 CEILING - CASSETTE (4-WAY)335 - 26-30-34 R410A 10.8 7.6 12.4 ---208 1 0.29 15 40 1, 2, 3, 4 FCU-353 MITSUBISHI/TRANE / TPLFYP005FM140A CU-03 CEILING - CASSETTE (4-WAY)280 - 26-28-30 R410A 4.5 4.2 5.1 ---208 1 0.24 15 40 1, 2, 3, 4 FCU-352 MITSUBISHI/TRANE / TPLFYP012FM140A CU-03 CEILING - CASSETTE (4-WAY)335 - 26-30-34 R410A 10.8 7.6 12.4 ---208 1 0.29 15 40 1, 2, 3, 4 FCU-321 MITSUBISHI/TRANE / TPLFYP005FM140A CU-03 CEILING - CASSETTE (4-WAY)280 - 26-28-30 R410A 4.5 4.2 5.1 ---208 1 0.24 15 40 1, 2, 3, 4 FCU-325 MITSUBISHI/TRANE / TPLFYP005FM140A CU-03 CEILING - CASSETTE (4-WAY)280 - 26-28-30 R410A 4.5 4.2 5.1 ---208 1 0.24 15 40 1, 2, 3, 4 FCU-326 MITSUBISHI/TRANE / TPLFYP006FM140A CU-03 CEILING - CONCEALED (DUCTED)300 0.6 24-28-30 R410A 5.4 5.4 6.2 FBM2-1-A 13 (1) 14 x 25 x 2 208 1 1.75 15 40 1, 2, 3, 4 FCU-331 MITSUBISHI/TRANE / TPLFYP005FM140A CU-03 CEILING - CASSETTE (4-WAY)280 - 26-28-30 R410A 4.5 4.2 5.1 ---208 1 0.24 15 40 1, 2, 3, 4 FCU-334 MITSUBISHI/TRANE / TPLFYP005FM140A CU-03 CEILING - CASSETTE (4-WAY)280 - 26-28-30 R410A 4.5 4.2 5.1 ---208 1 0.24 15 40 1, 2, 3, 4 FCU-335 MITSUBISHI/TRANE / TPLFYP006FM140A CU-03 CEILING - CONCEALED (DUCTED)300 0.6 24-28-30 R410A 5.4 5.4 6.2 FBM2-1-A 13 (1) 14 x 25 x 2 208 1 1.75 15 40 1, 2, 3, 4 FCU-341 MITSUBISHI/TRANE / TPLFYP005FM140A CU-03 CEILING - CASSETTE (4-WAY)280 - 26-28-30 R410A 4.5 4.2 5.1 ---208 1 0.24 15 40 1, 2, 3, 4 FCU-344 MITSUBISHI/TRANE / TPLFYP005FM140A CU-03 CEILING - CASSETTE (4-WAY)280 - 26-28-30 R410A 4.5 4.2 5.1 ---208 1 0.24 15 40 1, 2, 3, 4 FCU-345 MITSUBISHI/TRANE / TPLFYP006FM140A CU-03 CEILING - CONCEALED (DUCTED)300 0.6 24-28-30 R410A 5.4 5.4 6.2 FBM2-1-A 13 (1) 14 x 25 x 2 208 1 1.75 15 40 1, 2, 3, 4 FCU-351 MITSUBISHI/TRANE / TPLFYP005FM140A CU-03 CEILING - CASSETTE (4-WAY)280 - 26-28-30 R410A 4.5 4.2 5.1 ---208 1 0.24 15 40 1, 2, 3, 4 FCU-354 MITSUBISHI/TRANE / TPLFYP005FM140A CU-03 CEILING - CASSETTE (4-WAY)280 - 26-28-30 R410A 4.5 4.2 5.1 ---208 1 0.24 15 40 1, 2, 3, 4 FCU-355 MITSUBISHI/TRANE / TPLFYP006FM140A CU-03 CEILING - CONCEALED (DUCTED)300 0.6 24-28-30 R410A 5.4 5.4 6.2 FBM2-1-A 13 (1) 14 x 25 x 2 208 1 1.75 15 40 1, 2, 3, 4 FCU-421 MITSUBISHI/TRANE / PEAD-A18AA9 CU-04 CEILING - CONCEALED (DUCTED)600 0.6 27-28-33-36 R410A 15.9 13.0 9.7 FBM2-2-A 13 (1) 14 x 20 x 2 (1) 14 x 14 x 2 208 1 -- 40 1, 2, 3, 4, 5 FC-500 MITSUBISHI/TRANE / TPKA0A0121LA00A CU-05 WALL-MOUNTED 385 - 34-37-40-43 R410A 10.6 10.0 7.1 ---208 1 -- 40 1, 2, 3, 4, 5 1. CAPACITY RATINGS AT 80 F DB / 67 F WB INDOOR FOR COOLING; 70 F DB INDOOR FOR HEATING. 2. EACH INDOOR UNIT SHALL BE INDEPENDENTLY CAPABLE OF HEATING OR COOLING. 3. PROVIDE AND INSTALL CONDENSATE PUMP. 4. PROVIDE WITH REMOTE CONTROLLER. 5. POWERED BY OUTDOOR UNIT. VRF REFRIGERANT CONTROLLER SCHEDULE MFR / MODEL OUTDOOR MAX. NO.ELECTICAL WEIGHT TAG TYPE UNIT MARK BRANCHES VOLTS PHASE MCA MOCP (LBS)NOTES BCU-01 MITSUBISHI/TRANE / TCMBM0108JA11NA MAIN CU-02 8 208 1 0.83 15 110 1, 2 BCU-02 MITSUBISHI/TRANE / TCMBM1016JA11NA MAIN CU-03 16 208 1 1.57 15 110 1, 2 1. PROVIDE AND INSTALL CONDENSATE PUMP, X87-721 208/30V MAXIBLUE. 2. PROVIDE AND INSTALL DIAMONDBACK BALL VALVES BV-SERIES, 700 PSIG WORKING PRESSURE, FULL PORT, 410A RATED. ELECTRIC UNIT HEATER SCHEDULE TAG LOCATION MANUFACTURER/ MODEL AIRFLOW (CFM) ELECTRIC HEAT UNIT POWER REQUIREMENTS UNIT WT. (LBS) NOTESMIN CAP (BTUh) EAT (˚F) LAT (˚F)kW VOLTS Ø FLA UH-01 POOL MEP 103 QMARK/ MWUH7504 305 19,200 10 70 5.6 208 1 27.1 27 1,2 UH-02 STORAGE SHED QMARK/ MWUH7504 305 12,800 0 60 3.8 208 1 18.0 27 2 1. MOUNT HEATER MINIMUM OF 8'-0" ABOVE FLOOR LEVEL. 2. PROVIDE HEATER WITH WALL THERMOSTAT, SET TO MAINTAIN MINIMUM 55° IN ROOM. ELECTRIC WALL HEATER SCHEDULE TAG LOCATION MANUFACTURER/ MODEL BTU/H ELECTRICAL NOTESWATTS VOLTS PH EH-11 STAIR 1 GROUND FLOOR QMARK / CWH1101DSF 3413 1,000 120 1 1, 2, 3, 4 EH-12 STAIR 2 GROUND FLOOR QMARK / CWH1101DSF 3413 1,000 120 1 1, 2, 3, 4 EH-21 STAIR 1 2ND FLOOR QMARK / CWH1101DSF 3413 1,000 120 1 1, 2, 3, 4 EH-22 STAIR 2 2ND FLOOR QMARK / CWH1101DSF 3413 1,000 120 1 1, 2, 3, 4 EH-31 STAIR 1 3RD FLOOR QMARK / CWH1101DSF 3413 1,000 120 1 1, 2, 3, 4 EH-32 STAIR 2 3RD FLOOR QMARK / CWH1101DSF 3413 1,000 120 1 1, 2, 3, 4 EH-41 STAIR 1 4TH FLOOR QMARK / CWH1101DSF 3413 1,000 120 1 1, 2, 3, 4 EH-42 STAIR 2 4TH FLOOR QMARK / CWH1101DSF 3413 1,000 120 1 1, 2, 3, 4 EH-51 STAIR 1 5TH FLOOR QMARK / CWH1101DSF 3413 1,000 120 1 1, 2, 3, 4 EH-52 STAIR 2 5TH FLOOR QMARK / CWH1101DSF 3413 1,000 120 1 1, 2, 3, 4 1. HEATER SHALL BE SET TO MAINTAIN A TEMPERATURE OF 60°F IN STAIRWELL. 2. CONTRACTOR TO SUPPLY DOCUMENTATION FOR ALL UNITS AS PER WSEC C103.6. 3. UNIT TO BE SUPPLIED AND INSTALLED IN ACCORDANCE WITH STATE AND LOCAL CODE. 4. PROVIDE WITH SURFACE MOUNT KIT. www.coffman.com 221 N. Wall Street, Suite 500 Spokane, WA 99201 ph 509.328.2994 32 MERCHANT STREET, SUITE 208 HONOLULU, HI 96813 808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 99216MECHANICAL SCHEDULES M-701 FSC PROJECT NO. 21012 PERMIT SET MAY 30, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce Lane Spokane, WA 99206 (509) 919-0901 Revision Schedule Number Description Date 5/30/2024 EXHAUST FAN SCHEDULE TAG LOCATION SERVES MANUFACTURER/ MODEL DESCRIPTION FAN PERFORMANCE UNIT ELECTRICAL REQUIREMENTS UNIT WT. (LBS)NOTESTYPE DRIVE FLOW (CFM)ESP (" WC)SPEED (RPM) NOISE SONES HP VOLTS Ø MCA MOCP EF-01 POOL MECHANICAL ROOM ROOF POOL/SPLASH PAD EXHAUST GREENHECK / CUE-160-VG UPBLAST DIRECT (ECM)3,100 0.5 1259 16.6 2 208 1 16 30 181 1, 2, 4, 5 EF-02 POOL MECHANICAL ROOM ROOF POOL MEP AND RESTROOM EXHAUST GREENHECK / CUE-090-VG UPBLAST DIRECT (ECM)355 0.4 1346 5.9 1/10 120 1 2 15 90 1, 2, 3, 5 EF-03 FOOD PREP EXTERIOR WALL FOOD PREP EXHAUST HOOD CAPTIVEAIRE/ DU85HFA UPBLAST DIRECT (ECM)1,725 1 1370 12.3 3/4 230 1 171 6 EF-04 EMP RR EMP RR NUTONE / 6950 CEILING DIRECT 50 0.2 -4.0 - 120 1 1.5 15 5 7 EF-05 EMP RR ADA EMP RR ADA NUTONE / 6950 CEILING DIRECT 50 0.2 -4.0 - 120 1 1.5 15 5 7 1. PROVIDE WITH TOTALLY ENCLOSED MOTOR ENCLOSURE, NEMA-3R DISCONNECT SWITCH, 18" ROOF CURB, CURB SEAL, AND MODEL VCD-23-PB CONTROL DAMPER WITH 120 V ACTUATOR. 2. PROVIDE WITH CHEMICAL RESISTANT HI-PRO POLYESTER COATING ON ALL COMPONENTS IN THE AIRSTREAM, INCLUDING DAMPER. 3. PROVIDE WITH POTENTIOMETER DIAL FOR BALANCING. 4. PROVIDE WITH SPEED CONTROLLER THAT ACCEPTS 0-10 VDC INPUT FROM POOL AHU TO DRIVE MIN. OSA AND ECONOMIZER. 5. FAN SHALL RUN 24/7. 6. PROVIDE WITH THROUGH-WALL CURB, LOCKING HINGE KIT, GREASE DUCT CERAMIC SEAL, AND GREASE BOX. 7. FAN CONTROL BY MANUAL TIMER SWITCH IN WALL. GRILLES, REGISTERS, DIFFUSERS SCHEDULE GRILLE NECK PANEL THROW FRAME TAG TYPE MFR MODEL SIZE SIZE SIZE PATTERN MATERIAL STYLE FINISH NOTES 1S SUPPLY PRICE SMCD 6x6 6Ø -4-WAY STEEL SURFACE B12 2S SUPPLY PRICE SMCD 6x6 6Ø 24x24 4-WAY STEEL LAY IN B12 3S SUPPLY PRICE SMCD 8x8 8Ø -4-WAY STEEL SURFACE B12 4S SUPPLY PRICE SMCD 8x8 8Ø 24x24 4-WAY STEEL LAY IN B12 5S SUPPLY PRICE SMCD 10x10 10Ø -4-WAY STEEL SURFACE B12 6S SUPPLY PRICE SMCD 10x10 10Ø 24x24 4-WAY STEEL LAY IN B12 7S SUPPLY PRICE SMCD 12x12 12Ø -4-WAY STEEL SURFACE B12 8S SUPPLY PRICE SMCD 12x12 12Ø 24x24 4-WAY STEEL LAY IN B12 9S SUPPLY PRICE 510 6x4 6Ø -180º STEEL SURFACE B12 10S SUPPLY PRICE SDS100 60x1 SLOT 10Ø -180º ALUM. SURFACE B12 1R RETURN PRICE 535 6x6 6x6 -- STEEL SURFACE B12 2R RETURN PRICE 535 8x8 8x8 -- STEEL SURFACE B12 3R RETURN PRICE 535 8x8 8x8 24x24 - STEEL LAY IN B12 4R RETURN PRICE 535 14x12 14x12 24x24 - STEEL LAY IN B12 5R RETURN PRICE 535 14x14 14x14 24x24 - STEEL LAY IN B12 6R RETURN PRICE 535 16x16 16x16 24x24 - STEEL LAY IN B12 7R RETURN PRICE 535 24x20 24x20 -- STEEL SURFACE B12 8R RETURN PRICE 630 22x22 22x22 -- ALUM. SURFACE B12 1E EXHAUST PRICE 535 6x6 6x6 -- STEEL SURFACE B12 3 2E EXHAUST PRICE 535 6x6 6x6 24x24 - STEEL LAY IN B12 3E EXHAUST PRICE 535 8x8 8x8 -- STEEL SURFACE B12 3 4E EXHAUST PRICE 535 10x10 10x10 24x24 - STEEL LAY IN B12 5E EXHAUST PRICE 535 12x12 12x12 24x24 - STEEL LAY IN B12 6E EXHAUST PRICE 535 14x14 14x14 24x24 - STEEL LAY IN B12 7E EXHAUST PRICE 535 12x12 12x12 -- ALUM. DUCT B12 1. SEE FLOOR PLANS FOR CONNECTION SIZE 2. PROVIDE WITH SINGLE DEFLECTION OPTION. 3. IN RESTROOMS, JANITOR, AND MECHANICAL ROOMS USE ALUMINUM INSTEAD OF STEEL. SEISMIC AND VIBRATION CONTROL SEISMIC RESTRAINT PROVISIONS TAG EQUIPMENT LEVEL RESTRAINTS BASE FLEXIBLE CONNECTORS VIBRATION ISOLATORS COMPONENT IMPORTANCE FACTOR DEFLECTION (IN) SEISMIC SUPPORTS ARE REQUIRED FOR THIS PROJECT FOR ALL MECHANICAL AND ELECTRICAL EQUIPMENT AND DISTRIBUTION SYSTEMS. SEISMIC RESTRAINT CALCULATIONS MUST BE PROVIDED BY THE PRODUCT MANUFACTURER FOR ALL CONNECTIONS OF EQUIPMENT TO THE STRUCTURE. ALL RESTRAINING DEVICES SHALL HAVE TESTING DATA TO VALIDATE MAXIMUM RESTRAINT RATINGS. PREAPPROVALS BASED ON INDEPENDENT TESTING ARE PREFERRED TO PREAPPROVALS BASED ON CALCULATIONS. CALCULATIONS (INCLUDING THE COMBINING OF TENSILE AND SHEAR LOADING) TO SUPPORT SEISMIC RESTRAINT DESIGNS MUST BE STAMPED BY A REGISTERED PROFESSIONAL ENGINEER LICENSED IN WASHINGTON. THE ENGINEERING ANALYSIS MUST INDICATE CALCULATED DEAD LOADS, STATIC SEISMIC LOADS, AND CAPACITY OF MATERIALS UTILIZED FOR CONNECTIONS TO EQUIPMENT STRUCTURE. ANALYSIS MUST DETAIL ANCHORING METHODS, BOLT DIAMETER, EMBEDMENT, AND/OR WELDED LENGTH. AHU-01 POOL AIR HANDLING UNIT GRADE A B Y 1.5 ERV-01 ENERGY RECOVERY DOAS UNIT ROOF A D Y 1.5 CU-01 POOL CONDENSING UNIT ROOF A B NR 1.5 CU-02 VRF HEAT RECOVERY CONDENSING UNIT ROOF A B NR 1.5 CU-03 VRF HEAT RECOVERY CONDENSING UNIT ROOF A B NR 1.5 CU-04 HEAT PUMP CONDENSING UNIT ROOF A B NR 1.5 CU-05 HEAT PUMP CONDENSING UNIT ROOF A B NR 1.5 ALL SEISMIC RESTRAINT DEVICES SHALL BE DESIGNED TO ACCEPT, WITHOUT FAILURE, THE FORCES PRESCRIBED PER THE ASCE 7 ACTING THROUGH THE EQUIPMENT CENTER OF GRAVITY. OVERTURNING MOMENTS MAY EXCEED FORCES AT GROUND LEVEL AND MAY BE RESISTED BY SEISMIC RESTRAINTS, SUPPORT, OR ANCHORAGE. ANCHORAGE TO CONCRETE MUST HAVE AN ICC TESTING REPORT THAT ADHERES TO THE REQUIREMENTS OF THE IBC AND MUST BE RATED FOR SEISMIC RESTRAINT IN CRACKED CONCRETE USING THE APPROPRIATE REDUCTION FACTORS PER ACI 318 APPENDIX D. ACCEPTABLE ANCHORS INCLUDE THE HILTI KWIK BOLT TZ AND SIMPSON STRONG BOLT WEDGE ANCHORS OR HILTI HIT-RE 500-SD AND SIMPSON SET XP EPOXY ANCHORS. EPOXIES ARE NOT ACCEPTABLE FOR USE IN OVERHEAD APPLICATIONS. BCU-01 VRF BRANCH CONTROLLER UNIT 1ST CEILING A A NR 1.5 BCU-02 VRF BRANCH CONTROLLER UNIT 2ND CEILING A A NR 1.5 FCU-xx VRF DUCTED FAN COIL UNIT 1-5 CEILING A A NR 1.5 FCU-xx VRF CEILING CASSETTE 1-5 CEILING A A NR 1.5 FCU-500 WALL-MOUNTED HEAT PUMP UNIT 5TH FLOOR A NA NR 1.5 WH-01-04 DOMESTIC WATER HEATER GRADE A NR NR 1.5 EF-01 POOL EXHAUST FAN 2ND ROOF A D Y 1 ASCE 7-16 SEISMIC DESIGN CRITERIAEF-02 POOL MEP RM EXHAUST FAN 2ND ROOF A D Y 1 EF-03 FOOD PREP EXHAUST FAN 1ST CEILING A B Y 1 SEISMIC DESIGN CATEGORY "C" EF-04 BATHROOM EXHAUST FAN 1ST CEILING A A Y 1 RISK CATEGORY II EF-05 BATHROOM EXHAUST FAN 1ST CEILING A A Y 1 SITE CLASS "D" SEISMIC IMPORTANCE FACTOR FOR BUILDING, I = 1.0 DH-01 GAS DUCT HEATER 1ST CEILING A A Y 1.5 COMPONENT RESPONSE MODIFICATION AND AMPLIFICATION FACTORS SHALL BE DETERMINED IN ACCORDANCE WITH ASCE 7, TABLE 13.6-1. DESIGN SPECTRAL RESPONSE ACCELERATION AT SHORT PERIODS (0.2 SECOND): SDS = 0.324 G. DESIGN SPECTRAL RESPONSE ACCELERATION AT 1-SECOND PERIOD: SD1 = 0.177 G. RESTRAINTS BASE TYPE NOTES A = ANCHOR A = ISOLATOR ATTACHED TO EQUIPMENT DIRECTLY 1 CONCRETE PAD MASS TO EQUAL AT LEAST 75% OF EQUIPMENT AM = ANCHOR SPECIFIED BY EQUIPMENT MANUFACTURER B = STRUCTURAL STEEL RAILS OR BASE 2 NR=NOT REQUIRED, NA=NOT APPLICABLE B = RESTRAINING BASE WITH SNUBBER C = CONCRETE INERTIA BASE 3 PIPING TO BE BRACED LATERALLY A MINIMUM OF EVERY 40' AND LONGITUDINALLY EVERY 80' REGARDLESS OF SEISMIC REQUIREMENTS.Y = REQUIRED PER SPECIFICATION 23 05 40 D = CURB-MOUNTED BASE ISOLATOR TYPE 4 SEE SPECIFICATION SECTION 23 05 40 FOR DESCRIPTION AND REQUIREMENTS OF BASES, ISOLATORS, AND RESTRAINTS. 1. PAD: RUBBER, GLASS FIBER 4. RESTRAINED SPRING ISOLATOR 5 ALL PIPING GREATER THAN 1" MUST BE RESTRAINED 2. RUBBER ISOLATOR, FLOOR OR HANGER 5. THRUST RESTRAINT 6 EQUIPMENT VENDOR TO DETERMINE DEFLECTION 3. SPRING ISOLATOR, FLOOR OR HANGER 6. AIR SPRING COMPONENT IMPORTANCE FACTOR IF ONE OF THE FOLLOWING APPLY USE 1.5, OTHERWISE USE 1.0 1. THE COMPONENT IS REQUIRED TO FUNCTION FOR LIFE-SAFETY PURPOSES AFTER AN EARTHQUAKE, INCLUDING FIRE PROTECTION, SPRINKLER SYSTEMS AND EGRESS STAIRWAYS 2. THE COMPONENT CONVEYS, SUPPORTS, OR CONTAINS TOXIC OR EXPLOSIVE SUBSTANCES 3. THE COMPONENT IS IN OR ATTACHED TO A RISK CATEGORY IV STRUCTURE AND IT IS NEEDED FOR CONTINUED OPERATION OF THE FACILITY 4. THE COMPONENT CONVEYS, SUPPORTS, OR CONTAINS HAZARDOUS SUBSTANCES PACKAGE TERMINAL AIR CONDITIONER (HEAT PUMP) SCHEDULE TAG LOCATION MANUFACTURER/ MODEL UNIT PERFORMANCE UNIT ELECTRICAL REQUIREMENTS UNIT WT. (LBS) NOTESCFMCOOLING (BTU/H)MIN EER HEATING (BTU/H)MIN COP SUPPL. HEAT kW VOLTS Ø MCA MOCP PTAC-01 GUEST ROOM AMANA/ HEH093J35AXXXAA 307/335 9,000 13.00 8,000 3.78 3.0 208 1 19.5 20 106 1,2 1. PLUG-IN 208V 1-PH HEAT PUMP PTAC UNIT. REFRIGERANT MUST MEET WASHINGTON MAXIMUM 750 GWP. 2. PROVIDE WITH ELECTRIC HEAT ACCESSORY, HEAVY SOUND ISOLATION INSULATION SLEEVE, CONDENSATE DRAIN KIT, WIRE HARNESS KIT, AND ARCHITECTURAL OUTDOOR GRILLE (COORDINATE COLOR WITH ARCHITECT). GAS-FIRED DUCT HEATER TAG SERVES MANUFACTURER/ MODEL AIRFLOW INPUT MBH OUTPUT MBH DUCT DIMENSIONS (IN)UNIT ELECTRICAL REQUIREMENTS UNIT WT. (LBS) NOTESCFMEAT (F) LAT (F)WIDTH HEIGHT VOLTS Ø FLA DH-01 AHU-01 SUPPLY REZNOR/ EEDU-TSL-200 3100 49.6 95 200 141 22.5 18 115 1 2 172 1,2,3 MAU-01 MAU-01 CAPTIVEAIR/ A1-D.500-15D 1380 10 95 122 112 - - - - - - 1,3,4 1. PROVIDE WITH A HIGH LIMIT SAFETY SHUT-OFF, COMBUSTION AIR PRESSURE SWITCH, AIR-PROVING SWITCH, COMBINATION GAS VALVE WITH SHUTOFF. 2. DUCT HEATER SHALL BE MINIMUM 2-STAGE AND PROVIDED WITH THERMOSTAT TO BE INSTALLED IN THE OCCUPIED ZONE. 3. PROVIDE NECESSARY FLUE VENT/ OA INTAKE PIPING PER MANUFACTURER'S INSTALLATION INSTRUCTIONS. 4. GAS FURNACE IS PART OF PACKAGED MAKEUP AIR UNIT, INFORMATION SHOWN HERE FOR CLARITY. LOUVER SCHEDULE TAG SERVES MANUFACTURER/ MODEL MATERIAL FRAME TYPE AIRFLOW (CFM) LOUVER SIZE, WxH (IN) FACE AREA (SF) FACE VELOCITY (FPM) FREE AREA (SF) FREE AREA VELOCITY (FPM) APD (IN WC) DRAINABLE BLADE (YES/NO) BLADE ANGLE (DEG) FRAME DEPTH (IN) WEIGHT (LBS) BOTTOM OF LOUVER ELEVATION NOTES LV-01 POOLPAK INTAKE GREENHECK/ ESJ-401 ALUMINUM FIXED 3,100 44 x 44 13.44 231 6.60 469 0.04 NO 45 4 38 1,2 LV-02 POOLPAK EXHAUST GREENHECK/ ESJ-401 ALUMINUM FIXED 3,100 44 x 44 13.44 231 6.60 469 0.04 NO 45 4 38 1,2 LV-03 POOL MECH INTAKE GREENHECK/ EAC-401 ALUMINUM COMBINATION 355 20 x 20 2.78 128 0.80 459 0.03 YES 45 4 11 1,2,3 LV-04 LAUNDRY MAKE-UP AIR GREENHECK/ EAC-401 ALUMINUM COMBINATION 2,400 48 x 28 9.33 257 3.49 688 0.06 YES 45 4 28 1,2,3 LV-05 MAU-01 GREENHECK/ EDK-401 ALUMINUM FIXED 1,380 36 x 22 5.50 251 2.45 586 0.05 4 19 1,2 1. PROVIDE W/ INTERNAL ALUMINUM BIRD SCREEN. 2. COORDINATE FINAL LOUVER COLOR AND FINISH WITH OWNER PRIOR TO PURCHASE. 3. COMBINATION LOUVER PROVIDED WITH 24V, TWO-POSITION, FAIL-CLOSED, ACTUATOR TO BE INTERLINKED WITH EXHAUST FAN/DRYER EXHAUST OPERATION. DAMPER SCHEDULE TAG LOCATION SERVES MANUFACTURER/ MODEL TYPE WIDTH (IN) HEIGHT (IN) FLOW (CFM) FIRE RATING LEAKAGE CLASS CLOSE TEMP UNIT POWER REQUIREMENTS NOTES VOLTS Ø FLA FD-11 LINEN DISCHARGE RM RETURN AIR RUSKIN/ FDR25 FIRE 8Ø 165 1.5 HR CLASS I 165 - - - 1 FD-12 LINEN DISCHARGE RM SUPPLY AIR RUSKIN/ FDR25 FIRE 6Ø 100 1.5 HR CLASS I 165 - - - 1 FSD-11 GROUND FLOOR SHAFT ERV-01 EXHAUST RUSKIN/ FSD60 FIRE/SMOKE 22 18 2,555 1.5 HR CLASS I 165 120 1 - 1 FSD-12 GROUND FLOOR SHAFT ERV-01 SUPPLY RUSKIN/ FSD60 FIRE/SMOKE 22 18 2,555 1.5 HR CLASS I 165 120 1 - 1 FSD-21 2ND FLOOR SHAFT ERV-01 EXHAUST RUSKIN/ FSD60 FIRE/SMOKE 26 10 1,365 1.5 HR CLASS I 165 120 1 - 1 FSD-22 2ND FLOOR SHAFT ERV-01 SUPPLY RUSKIN/ FSD60 FIRE/SMOKE 26 10 1,365 1.5 HR CLASS I 165 120 1 - 1 FSD-31 3RD FLOOR SHAFT ERV-01 EXHAUST RUSKIN/ FSD60 FIRE/SMOKE 26 10 1,365 1.5 HR CLASS I 165 120 1 - 1 FSD-32 3RD FLOOR SHAFT ERV-01 SUPPLY RUSKIN/ FSD60 FIRE/SMOKE 26 10 1,365 1.5 HR CLASS I 165 120 1 - 1 FSD-41 4TH FLOOR SHAFT ERV-01 EXHAUST RUSKIN/ FSD60 FIRE/SMOKE 26 10 1,365 1.5 HR CLASS I 165 120 1 - 1 FSD-42 4TH FLOOR SHAFT ERV-01 SUPPLY RUSKIN/ FSD60 FIRE/SMOKE 26 10 1,365 1.5 HR CLASS I 165 120 1 - 1 FSD-51 5TH FLOOR SHAFT ERV-01 EXHAUST RUSKIN/ FSD60 FIRE/SMOKE 26 10 1,365 1.5 HR CLASS I 165 120 1 - 1 FSD-52 5TH FLOOR SHAFT ERV-01 SUPPLY RUSKIN/ FSD60 FIRE/SMOKE 26 10 1,365 1.5 HR CLASS I 165 120 1 - 1 1. FAIL CLOSED www.coffman.com 221 N. Wall Street, Suite 500 Spokane, WA 99201 ph 509.328.2994 32 MERCHANT STREET, SUITE 208 HONOLULU, HI 96813 808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 99216MECHANICAL SCHEDULES M-702 FSC PROJECT NO. 21012 PERMIT SET MAY 30, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce Lane Spokane, WA 99206 (509) 919-0901 Revision Schedule Number Description Date 5/30/2024 DEDICATED OUTDOOR AIR UNIT SCHEDULE TAG LOCATION SERVES MANUFACTURER / MODEL SUPPLY FAN EXHAUST FAN ENERGY RECOVERY MODULE COOLING CAPACITY HEATING CAPACITY UNIT ELECTRICAL REQUIREMENTS AIR FILTERS SIZE (WxLxH) UNIT WT. (LBS) NOTESTOTAL CFM ESP (IN. WC) MOTOR DATA TOTAL CFM ESP ("WC) MOTOR DATA OAT DB/WB (°F) LAT DB/WB (°F) OAT DB/WB (°F) LAT DB/WB (°F) SENS. (MBH) TOTAL (MBH) EDB (F) EWB (F) LAT (F) EFF. (%) INPUT (MBH) OUTPUT (MBH)AFUE (%)# MERVBHP HP RPM DRIVE BHP HP RPM DRIVE VOLTS Ø MCA MOCP ERV-01 ROOF HOTEL AAON / RNA-026-D-A-8 8200 1.6 10.2 7.5 1302 DIRECT 8200 1.6 5.84 5 1250 DIRECT 96/63 90.7/63 57.1/50.4 24.2/24.1 121 21.6 96 63 80 109.6 550 440 80 208 3 88.00 125 8 8 - EA 13 - OSA 100x209x87 5067 1,2,3,4,5,6 1. UNIT HAS ENERGY RECOVERY WHEEL. 2. PROVIDE UNIT WITH 36" ROOF CURB WITH SIDE CONNECTIONS FOR SUPPLY AND EXHAUST. ROOF CURB SHALL INCLUDE INSULATION OR INSULATION PANELS AND SPRING ISOLATORS ACCORDING TO VIBRATION SCHEDULE. 3. PROVIDE DOAS WITH BOTTOM CONNECTIONS AND 24V MOTORIZED ISOLATION DAMPERS FOR EXHAUST AND OUTSIDE AIR. PROVIDE WEATHERHOODS ON OA INTAKE AND EXHAUST OUTLET. 4. PROVIDE MODULATING GAS MODULE WITH 10:1 TURNDOWN RATIO. 5. PROVIDE MODULATING SUPPLY AND EXHAUST FANS WITH VFDS. 6. PROVIDE WITH 10k SCCR RATING AND INTEGRAL DISCONNECT. OUTDOOR CONDENSING UNIT SCHEDULE TAG MFR / MODEL TYPE UNIT SIZE (TONS)REFRIGERANT REFRIGERANT CHARGE (LBS) TOTAL COOLING CAPACITY (MBh) SENSIBLE COOLING CAPACITY (MBh) HEATING CAPACITY (MBh) EER (MIN) [SEER]IEER (MIN) COP (MIN) @ 47°F [HSPF] SOUND PRESS. ELECTRICAL WEIGHT (LBS)AREA SERVED NOTESVOLTS PHASE MCA MOCP CU-01 POOLPAK / NC-Z-1V REMOTE AIR-COOLED CONDENSER 5 R-410A -102 54.6 127 - -- 60 460 3 3 15 150 POOL 2, 6, 7 CU-02 MITSUBISHI/TRANE / TURYH2404BN41AN VRF HEAT RECOVERY HEAT PUMP 20 R-410A 49.0 213 -211 19.6 9.85 3.46 87.5/88.5 460 3 35 50 1500 GROUND FLOOR 1, 2, 3, 4, 5, 6, 7 CU-03 MITSUBISHI/TRANE / TURYH1444BN41AN VRF HEAT RECOVERY HEAT PUMP 6 R-410A 56.9 128 -150 20.65 11.15 3.63 78.5/80 460 3 25 40 1250 LINEN ROOMS, ELEVATOR LOBBIES, AND CORRIDORS 1, 2, 3, 4, 5, 6, 7 CU-04 MITSUBISHI/TRANE / TRUZA0181KA70NA REMOTE HEAT PUMP 1.5 R-410A -16 -10 [14.3] - [10] 44/46 208 3 11 28 150 SERVER ROOM 1, 3, 4, 6, 7 CU-05 MITSUBISHI/TRANE / TRUZA0121KA70NA REMOTE HEAT PUMP 1 R-410A -11 -7 [21] - [10.2] 44/46 208 3 11 28 150 ELEVATOR MACHINE SPACE 1, 3, 4, 6, 7 1. PERFORMANCE AT 0 F WINTER AND 100 F DB / 64 F WB SUMMER. OPERATING RANGE: HEATING -22 F DB TO 60 F DB, COOLING 23 F DB TO 126 F DB. 2. UNIT IS COMPOSED OF TWO MODULES. SEPARATE POWER CONNECTION REQUIRED FOR EACH INDIVIDUAL MODULE: ELECTRICAL INFORMATION SHOWN IS FOR ONE MODULE. 3. ADDITIONAL REFRIGERANT CHARGE TO BE DETERMINED BY MECHANICAL CONTRACTOR AND EQUIPMENT MANUFACTURER. 4. SEE SYSTEM TREE FOR PIPE SIZES. 5. PROVIDE WITH MODEL TWINNING KIT. 6. PROVIDE WITH STANDS SIZED FOR THIS CONDENSING UNIT. 24" TALL, AND 1" DEFLECTION SPRING ISOLATORS, QUANITITY AND SIZE TO BE DETERMINED BY MANUFACTURER. 7. PROVIDE WITH SNOW/HAIL GUARDS KIT. www.coffman.com 221 N. Wall Street, Suite 500 Spokane, WA 99201 ph 509.328.2994 32 MERCHANT STREET, SUITE 208 HONOLULU, HI 96813 808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 99216MECHANICAL SCHEDULES M-703 FSC PROJECT NO. 21012 PERMIT SET MAY 30, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce Lane Spokane, WA 99206 (509) 919-0901 Revision Schedule Number Description Date 5/30/2024 FDFDD D D DWWWWFDFDD D D DWWWWABCDC.1EFGHJKL.1MNPQ98.1876.16543.132.11.12COGWCO & V111GREASE INTERCEPTOR2" W UP3" W UP2" W UP2" W4" W4" W4" W4" W4" W4" W4" W4" W4" W4" W11111SP-1SP-218"X18"X18"SUMP2112" W2" W6" W4" W2" WCOG5" RD UP4" W4" W4" W4" W UP2" W4" WFCO2" WFD4" W4" W UPHUB DRAIN3/4" G3" G3" G3/4" G1/2" G3/4" G1/2" G1/2" G3" GDF-12" W1 1/2" V2" V4" WWCO3" W4" W4" W4" W4" WFSFSBF-16" CW, SEE CIVIL FOR CONTINUATION 6" W6" W6" W4" WBF-14" W6" W2" W2" V1 1/2" V4" W4" W4" W4" W3" VFDFSWCO2" W UP TO WCO THEN 2" V UP2" V UP2" V UP2" W UP TO WCO THEN 2" V2" PW34" RAD4" RAD4" RAD4" RAD4" RAD6" RAD6" RAD6" RAD4" RAD6" RAD4" RAD4" RAD4" RAD4" RAD4" RAD8" RAD UP1/2" G TO PRE-MANUFACTURED FIREPIT1/2" G TO PRE-MANUFACTURED FIREPIT1/2" G TO BARBEQUE1-1/2" G TO GENERATOR, SEE ELECTRICAL PLANS FOR LOCATION -PROVIDE ISOLATION VALVE (REGULATOR BY VENDOR)2" W2" W2" W6" W2" W, TYP.3" RD3" RD3" RDFSFS2" VMIN. 5'-0"5" RD5" RDI.E. = 3'-11" BFFSEE CIVIL PLANS FOR CONTINUATIONI.E. = 3'-6" BFFSEE CIVIL PLANS FOR CONTINUATIONI.E. = 3'-5" BFFSEE CIVIL PLANS FOR CONTINUATION2" WI.E. = 4'-4" BFFSEE CIVIL PLANS FOR CONTINUATION2" V2" W2" W2" W3" W3" W2" W2" W2" W3" W2" W2" W2" W2" V2" V2" W2" W3" W2" V2" V2" V2" V2" VCOCOCO44224" RD = 3'-6" BFF.SEE CIVIL PLANS FOR CONTINUATION.2GENERAL UNDERSLAB PLUMBING NOTESA. ALL PIPING SHALL BE SLEEVED AND SEALED THROUGH ANY STRUCTURE OR CONCRETE. B. WASTE AND VENT PIPING SHALL BE NO-HUB CAST IRON OR SCHEDULE 40 PVC DWV.C. SLOPE ALL BELOW GRADE SANITARY AND RAIN DRAIN PIPING AT 1/4" PER FOOT, MIN. UNO.D. TRAP PRIMER PIPING NOT SHOWN FOR CLARITY. SEE FLOOR PLANS FOR WATER AND DRAIN LOCATIONS, AND PLUMBING FIXTURE SCHEDULE FOR PRIMER REQUIREMENTS.E. CONTRACTOR TO BLOCK OUT/SLEEVE CONCRETE STEM WALLS WHERE REQUIRED TO ACCOMMODATE PIPING (OR CORE DRILL AFTER CONCRETE IS POURED).F. ALL RADON PIPING NOT BURIED BELOW SLAB SHALL BE SCHEDULE 40 PVC OR SCHEDULE 40 ABS, AND CLEARLY LABELED "RADON PIPE". ALL JOINTS AND CONNECTIONS MUST BE GAS TIGHT. ANY HORIZONTAL RADON VENT PIPE MUST BE SLOPED TO PROVIDE DRAINAGE TO GROUND UNDER SLABG. ALL RADON PIPING BURIED BELOW SLAB SHALL BE ADS DOUBLEWALL CORRUGATED POLYETHYLENE N-12 PERFORATED PIPE. TOP OF PIPE SHALL BE 1" BELOW BOTTOM OF SLAB. EMBED IN 3/8" PEA GRAVEL MIN 4" ALL AROUND. CAP ALL PIPE ENDS.H. ALL BURIED GAS PIPING TO BE POLYETHYLENE (PE) WITH TRACER WIRE INSTALLED 6" ABOVE. GROUND COVER TO BE A MINIMUM OF 18". INSTALL PER 2021 IFGC. ALL EXPOSED GAS PIPING TO BE SCH. 40 BLACK STEEL. PIPING IS SIZED AT 2 PSI DELIVERY WITH MAXIMUM 1 PSI PRESSURE DROP. I. SEE RISER DIAGRAMS ON SHEETS P-601 THROUGH P-605 FOR ALL PIPE SIZING SERVING GUEST ROOMS.www.coffman.com221 N. Wall Street, Suite 500Spokane, WA 99201ph 509.328.299432 MERCHANT STREET, SUITE 208HONOLULU, HI 96813808-352-5299NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.OWNER:THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 99216UNDERFLOORPLUMBING PLANP-100 FSC PROJECT NO. 21012PERMIT SETMAY 30, 2024GL8 MirabeauPoint, LLCTMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-09013/32" = 1'-0"UNDERFLOOR PLUMBING PLANKEY NOTES1PROVIDE MIN. 8' HORIZONTAL PIPE LENGTH ON SUDS STACKSPRIOR TO CONNECTION TO MAIN.2 VERIFY LOCATION WITH ELEVATOR MANUFACTURE'SINSTALLATION INSTRUCTIONS.3 USE TYPE 'K' COPPER FOR PUMPED WASTE. ROUTE BELOWGRADE TO LAUNDRY TROUGH. INSTALL FINAL TERMINATION INLAUNDRY TROUGH PER 13/P-501.4 CONNECT TO POOL DECK DRAIN SYSTEM WITH P-TRAP ANDTRAP PRIMER. MANIFOLD TRAP PRIMER PIPING IN POOL MECHROOM.0'6'12'24'SCALE: 3/32" = 1'-0"Revision ScheduleNumber Description Date2 Addendum26/21/20242PRELIMINARYNOT FOR CONSTRUCTION5/30/2024I.E. ABCDEFGHJKL.1MNPQ98.1876.1655443.13.1332.12.11.11.122LOBBY121FOOD PREP123EFFICIENCY129EFFICIENCY131EFFICIENCY133DOUBLE QUEEN135KING STUDIO137LANAI137ALANAI135AKING STUDIO ADA-M-T138DOUBLE QUEEN136EFFICIENCY134STAIR 2132KING STUDIO130ELECTRICAL128SALES OFFICE126GM OFFICE125OPEN OFFICE124OWNER'S OFFICE127VESTIBULE122MEETING ROOM120MEETING STORAGE119GUEST STORAGE118WOMEN'S RESTROOM115MEN'S RESTROOM116ELEVATOR LOBBY117ELEV 2113ELEV 1111HOUSEKEEPING OFFICE109AFITNESS114LAUNDRY LOUNGE112EMP RR ADA110AEMPLOYEE ROOM110WATER HEATER & FIRE108STAIR 1106BOH LAUNDRY105LINEN DISCHARGE &SORTING107ELECTRICAL104PUBLIC CORRIDOR100POOL MEP103POOL & SPLASH PAD101POOL RESTROOM102P-4011P-4014P-4021P-4022SH-5L-1WC-2DF-1FD-1WH-1FD-1FD-1FCOS-1S-3EW-14" HWWC-22" W UPWC-2L-1L-1FD-1FD-1FD-1L-1L-1FD-1WC-2WC-2WC-2WC-2FD-1U-1U-1L-1L-14" W UP4" WCO4" WCOGREASE INTERCEPTORWCO1/2" G DN TO DRYER (TYP)4" W1/2" G TO PRE-MANUFACTURED FIREPIT -PROVIDE ISOLATION VALVE (REGULATOR BY VENDOR)1/2" G TO PRE-MANUFACTURED FIREPIT-PROVIDE ISOLATION VALVE (REGULATOR BY VENDOR)1/2" G TO BARBEQUE-PROVIDE ISOLATION VALVE (REGULATOR BY VENDOR)RISER-1RISER-2RISER-4RISER-3RISER-5RISER-6RISER-7RISER-8RISER-9RISER-10RISER-11RISER-12RISER-13RISER-14RISER-15RISER-16RISER-18RISER-17RISER-19RISER-20RISER-22RISER-21RISER-23RISER-25RISER-24RISER-26RISER-27RISER-29RISER-28RISER-30RISER-31L-1111111111111111MGAS METER BY UTILITY3/4" G DN TO DH-011" G DN TO POOL BOILERFD-11 1/4" G1 1/4" G1 1/4" G1" G1/2" G3/4" G1 1/2" G1" G1" G UP TO ERV-012" GOVERFLOW ROOF DRAINDS-11" HW1" HW1" CW1" CW1" HW1" CW4" HW3" CW1 1/2" HW2" CW2" HWFCO2" W UP2" WASTE UP TO CLOTHS WASHER -ROUTE BELOW SANITARY SERVING SINK AND TIE DIRECTLY INTO MAIN BELOW CHASE2" W2" W2" W2" W SERVING SINK ABOVE4" WHB-2COGCOG2222222223/4" HWC2224" W3/4" HWC2.5 GPM2" CW2 1/2" CW3" CW4" CW2" CW2" CW1 1/4" CW TO POOL MAKE-UPWATER SOFTENERSP-40311" HW 140°F3/4" HWC (140° F)3/4" CW1/2" CW2" V2" V1 1/2" CW1/2" HWBF-11 1/4" CW1 1/4" HW1 1/2" CW1 1/4" HWFS-14" W DN22" V3" VBF-12" V1/2" CW3/4" HWC1" HW1 1/4" HWC3" HW3" CW3/4" HWC1" HW1" HWC2 1/2" HW1" HWC2 1/2" HW2 1/2" CW1" HWC2" HW2" CW3/4" HWC1 1/2" HW1 1/2" CW4" W(LOW TEMP)4" CW1 1/4" HWC4" HW4" CW1 1/4" HWC4" HW4" CW1 1/2" HWC3/4" HWC1" HW3/4" HWC3/4" CWWCO2" W3" RD3" ORD3" RD3" ORD3" UP TO RDL/ODL ABOVE4" W4" WMAU-01FD-1HB-1HB-11/2" CW3/4" CW3/4" CWHIGH TEMP 140°F HW DN TO MOP SINK1/2" G TO MAU-1FS-1FS-1COGCOG2" VTD-2HUB DRAIN, SEE DETAIL 122" V2" V2" V2" V2" V2" V2" V2" V2" V22" V22OVERFLOW ROOF DRAIN4" ORD2GENERAL PLUMBING NOTESA. PLUMBING PLANS SHOW GENERAL ROUTING AND ARRANGEMENT OF PIPING. B. CONTRACTOR SHALL COORDINATE ROUTING AND SPACE REQUIREMENTS OF PIPING WITH STRUCTURAL MEMBERS AND ALL OTHER TRADES INCLUDING HVAC, FIRE PROTECTION, ELECTRICAL, AND COMMUNICATIONS/DATA. OFFSET PIPING AROUND DUCTWORK AND OTHER OBSTACLES WHERE REQUIRED.C. ALL PIPING SHALL BE SLEEVED AND SEALED THROUGH ANY STRUCTURE OR CONCRETE. D. DOMESTIC WATER PIPE SIZING SHOWN IS BASED ON TYPE ‘L’COPPER WATER TUBING. WHEN PEX PIPING IS SUBSTITUTED (IF APPROVED FOR USE), THE CONTRACTOR SHALL UPSIZE PIPING ACCORDINGLY SO THE INSIDE DIAMETER OF THE PEX PIPING MATCHES THE INSIDE DIAMETER OF TYPE ‘L’ COPPER PIPING.E. COORDINATE PLUMBING VENT LOCATIONS WITH MECHANICAL. LOCATE PLUMBING VENTS 10'-0" MIN. FROM ANY BUILDING OPENING OR HVAC AIR INTAKE.F. WASTE AND VENT PIPING SHALL BE NO-HUB CAST IRON OR SCHEDULE 40 PVC DWV. EXPOSED WASTE AND VENT PIPING SHALL BE CAST IRON.G. ABOVE GRADE RAIN DRAIN AND OVERFLOW DRAIN PIPING SHALL BE SCHED. 40 PVC DWV. RAIN DRAIN RISERS SHALL BE CAST IRON.H. SLOPE ALL ABOVE GRADE RAIN DRAIN AND OVERFLOW DRAIN PIPING AT 1/4" PER FOOT, MIN. UNO.I. PROVIDE AND INSTALL CLEANOUTS AT THE BASE OF ALL ROOF DRAINS.J. CONDENSATE DRAIN PIPING SHALL BE TYPE 'L' OR 'M' COPPER. SLOPE ALL CONDENSATE DRAIN PIPING AT 1/8" PER FOOT, MIN.K. SEE ARCHITECTURAL FOR FIXTURE MOUNTING HEIGHTS.L. SEE PLUMBING FIXTURE SCHEDULE FOR PIPE SIZING OF BRANCH CLOSEST TO FIXTURE. TRAP ARMS MAY BE SIZED THE SAME AS FIXTURE OUTLET. UNDERGROUND PIPING SHALL BE NO LESS THAN 2".M. TRAP PRIMER PIPING NOT SHOWN FOR CLARITY. SEE FLOOR PLANS FOR WATER AND DRAIN LOCATIONS, AND PLUMBING FIXTURE SCHEDULE FOR PRIMER REQUIREMENTS.N. INSTALL WATER HAMMER ARRESTORS IN CONFORMANCE WITH MANUFACTURER'S INSTRUCTIONS AND GUIDELINES.O. PROVIDE ACCESS DOORS TO ALL CONCEALED VALVES AND WATER HAMMER ARRESTORS.P. PROVIDE AND INSTALL CLEANOUTS AT ALL SINKS AND URINALS.Q. PROVIDE ISOLATION VALVES AT ACCESSIBLE LOCATIONS FOR ALL WATER PIPING BRANCHES, INCLUDING ALL HOSE BIBBS AND RESTROOMSR. LOCATE DOWNSPOUT NOZZLES AT 18" AFF.S. REFER TO ARCHITECTURAL FOR VTR FLASHING DETAILS. FLASHING TO BE COMPATIBLE WITH ROOFING SYSTEM.T. NO PIPING SHALL PENETRATE THE SHEAR WALL TOP OR BOTTOM PLATE. PIPING TO FLOORS ABOVE OR BELOW SHALL USE DESIGNATED CHASES OR GO THROUGH NON-SHEAR WALLS.U. PROVIDE A MANUAL CIRCUIT SETTER ON EACH HWC RISER BEFORE IT CONNECTS TO THE MAIN HWC LINE ON LEVEL 1. SET TO 0.75 GPM. V. SEE RISER DIAGRAMS ON SHEETS P-601 THROUGH P-605 FOR ALL PIPE SIZING SERVING GUEST ROOMS.FLOOR4" WPIPING BY POOL CONTRACTOR72" MAX12" MINP-TRAP2" V4" W6" AIR GAP2'-0" MIN.12" MIN2" MAX.1/2" WIRE MECH STRAINER SECURED IN HUB DRAINWYE AND 1/8" BEND COMBOwww.coffman.com221 N. Wall Street, Suite 500Spokane, WA 99201ph 509.328.299432 MERCHANT STREET, SUITE 208HONOLULU, HI 96813808-352-5299NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.OWNER:THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 99216GROUND FLOORPLUMBING PLANP-101FSC PROJECT NO. 21012PERMIT SETMAY 30, 2024GL8 MirabeauPoint, LLCTMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-09013/32" = 1'-0"GROUND FLOOR PLUMBING PLANKEY NOTES12" W UP SERVING FIXTURE IN ROOM ABOVE, 2" V DN IN WALLSERVING FIXTURE BELOW.2 3/4" HWC FROM 4TH FLOOR. SEE DOMESTIC WATER RISERDIAGRAM. LOCATE CIRCUIT SETTER IN ACCESSIBLE LOCATION INHALLWAY.0'6'12'24'SCALE: 3/32" = 1'-0"Revision ScheduleNumber Description Date2 Addendum26/21/2024NTS2BACKWASH DRAIN2 PRELIMINARYNOT FOR CONSTRUCTION5/30/2024 A A B B C C D C.1 E E F F G G H H J J K K L.1 L.1 M M N N P P Q Q 99 8.1 88 77 6.1 66 5 44 3.13.1 33 2.12.1 1.1 2 2 KING 1-BEDROOM ENLARGED 201 KING 1-BEDROOM 202 KING STUDIO 204 EFFICIENCY ENLARGED 203 EFFICIENCY 205 STAIR 1 206 EFFICIENCY 208 ENGINEERING OFFICE & STORAGE 207 DOUBLE QUEEN 210 DOUBLE QUEEN ENLARGED 212 KING STUDIO 214 KING STUDIO 216 KING STUDIO 218 KING STUDIO 220 DOUBLE QUEEN 222 DOUBLE QUEEN 224 KING STUDIO 226 EFFICIENCY 228 KING STUDIO 230 STAIR 2 232 EFFICIENCY 234 DOUBLE QUEEN 236 DOUBLE QUEEN 235 EFFICIENCY 233 EFFICIENCY 231 EFFICIENCY 229EFFICIENCY 227 KING STUDIO 225 KING STUDIO 223KING STUDIO 221 KING STUDIO 219ELEVATOR LOBBY 217 ELEV 1 111 ELEV 2 113 PBX/MDF 207A P-401 3 P-401 5 P-402 4 P-402 5 1 1 11 1 1 RISER-1 RISER-2 RISER-4 RISER-3 RISER-5 RISER-6 RISER-7 RISER-8 RISER-9 RISER-11 RISER-12 RISER-13 RISER-14 RISER-15 RISER-16 RISER-18RISER-17 RISER-19 RISER-20 RISER-22RISER-21 RISER-23 RISER-25RISER-24 RISER-26 RISER-27 RISER-29RISER-28 RISER-30 RISER-31 RISER-10 RD-1OD-1 RD-1OD-1 KING STUDIO ADA-M-T 238 KING STUDIO 237 www.coffman.com 221 N. Wall Street, Suite 500 Spokane, WA 99201 ph 509.328.2994 32 MERCHANT STREET, SUITE 208 HONOLULU, HI 96813 808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 992162ND FLOOR PLUMBING PLAN P-102 FSC PROJECT NO. 21012 PERMIT SET MAY 30, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce Lane Spokane, WA 99206 (509) 919-0901 3/32" = 1'-0" 2ND FLOOR PLUMBING PLAN KEY NOTES 1 CONNECT BALCONY DRAIN TO PTAC CONDENSATE RISER. 0'6'12'24' SCALE: 3/32" = 1'-0" Revision Schedule Number Description Date 5/30/2024 A A B B C C D C.1 E E F F G G H H J J K K L.1 L.1 M M N N P P Q Q 99 8.1 88 77 6.1 66 55 44 3.13.1 33 2.12.1 1.11.1 2 2 KING 1-BEDROOM ADA-M-T 301 KING 1-BEDROOM ADA-M-T 301 KING 1-BEDROOM 302 KING STUDIO 304 EFFICIENCY ENLARGED 303 EFFICIENCY 305 STAIR 1 306 EFFICIENCY 307 EFFICIENCY 308 DOUBLE QUEEN 310 LINENES & HOUSEKEEPING 309 ELEV 1 111 ELEV 2 113 ELEVATOR LOBBY 317 DOUBLE QUEEN ENLARGED 312 KING STUDIO 314 KING STUDIO 316 KING STUDIO 318 KING STUDIO 320 DOUBLE QUEEN 322 DOUBLE QUEEN 324 KING STUDIO 326 EFFICIENCY 328 KING STUDIO 330 STAIR 2 332 EFFICIENCY 334 DOUBLE QUEEN 336 KING STUDIO ADA-M-RI 338 KING STUDIO 337DOUBLE QUEEN 335 EFFICIENCY 333 EFFICIENCY 331 EFFICIENCY 329 EFFICIENCY 327 KING STUDIO 325 KING STUDIO 323 KING STUDIO 321 KING STUDIO 319 P-401 2 P-402 6 1 1 1 1 1 1 1 1 RISER-1 RISER-2 RISER-4 RISER-3 RISER-5 RISER-6 RISER-8 RISER-9 RISER-11 RISER-12 RISER-13 RISER-14 RISER-15 RISER-16 RISER-18RISER-17 RISER-19 RISER-20 RISER-22RISER-21 RISER-23 RISER-25RISER-24 RISER-26 RISER-27 RISER-29RISER-28 RISER-30 RISER-31 www.coffman.com 221 N. Wall Street, Suite 500 Spokane, WA 99201 ph 509.328.2994 32 MERCHANT STREET, SUITE 208 HONOLULU, HI 96813 808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 992163RD FLOOR PLUMBING PLAN P-103 FSC PROJECT NO. 21012 PERMIT SET MAY 30, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce Lane Spokane, WA 99206 (509) 919-0901 3/32" = 1'-0" 3RD FLOOR PLUMBING PLAN KEY NOTES 1 CONNECT BALCONY DRAIN TO PTAC CONDENSATE RISER. 0'6'12'24' SCALE: 3/32" = 1'-0" Revision Schedule Number Description Date 5/30/2024 A A B B C C D C.1 E E F F G G H H J J K K L.1 L.1 M M N N P P Q Q 99 8.1 88 77 6.1 66 55 44 3.13.1 33 2.12.1 1.11.1 2 2 KING STUDIO 437 DOUBLE QUEEN 435EFFICIENCY 433 EFFICIENCY 431 EFFICIENCY 429KING STUDIO 425 KING STUDIO 423 KING STUDIO 421KING STUDIO 419 LINENES & HOUSEKEEPING 409 ELEV 1 111 ELEV 2 113 EFFICIENCY 407 EFFICIENCY 405 EFFICIENCY ADA-M-RI 403 KING 1-BEDROOM ENLARGED 401KING 1-BEDROOM 402 KING STUDIO 404 STAIR 1 406 EFFICIENCY 408 DOUBLE QUEEN 410 DOUBLE QUEEN ENLARGED 412 KING STUDIO 414 KING STUDIO 416 KING STUDIO 418 KING STUDIO 420 DOUBLE QUEEN 422 DOUBLE QUEEN 424 KING STUDIO 426 EFFICIENCY 428 KING STUDIO 430 STAIR 2 432 DOUBLE QUEEN 436 KING STUDIO ENLARGED 438 ELEVATOR LOBBY 417 P-401 6 1 1 1 1 1 1 1 1 2 2 2 RISER-1 RISER-2 RISER-4 RISER-3 RISER-5 RISER-6 RISER-7 RISER-8 RISER-9 RISER-10 RISER-11 RISER-12 RISER-13 RISER-14 RISER-15 RISER-16 RISER-18RISER-17 RISER-19 RISER-20 RISER-22RISER-21 RISER-23 RISER-25RISER-24 RISER-26 RISER-27 RISER-29 RISER-28 RISER-30 RISER-31 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 22 2 2 22 22 2 2 22 22 22 22 22 2 2 2 2 2 2 2 2 2 22 2 HWC DN TO GROUND FLOOR 5" ORD 5" RD 8" RAD UP www.coffman.com 221 N. Wall Street, Suite 500 Spokane, WA 99201 ph 509.328.2994 32 MERCHANT STREET, SUITE 208 HONOLULU, HI 96813 808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 992164TH FLOOR PLUMBING PLAN P-104 FSC PROJECT NO. 21012 PERMIT SET MAY 30, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce Lane Spokane, WA 99206 (509) 919-0901 3/32" = 1'-0" 4TH FLOOR PLUMBING PLAN KEY NOTES 1 CONNECT BALCONY DRAIN TO PTAC CONDENSATE RISER. 2 2" W UP SERVING FIXTURE IN ROOM ABOVE, 2" V DN IN WALL SERVING FIXTURE BELOW. 0'6'12'24' SCALE: 3/32" = 1'-0" Revision Schedule Number Description Date 5/30/2024 A A B B C C D C.1 E E F F G G H H J J K K L.1 L.1 M M N N P P Q Q 99 8.1 88 77 6.1 66 55 44 3.13.1 33 2.1 1.11.1 2 1 1 1 1 1 1 1 1 RISER-1 RISER-2 RISER-4 RISER-3 RISER-5 RISER-6 RISER-7 RISER-8 RISER-9 RISER-10 RISER-11 RISER-12 RISER-13 RISER-14 RISER-15 RISER-16 RISER-18RISER-17 RISER-19 RISER-20 RISER-22 RISER-21 RISER-23 RISER-25RISER-24 RISER-26 RISER-27 RISER-29 RISER-28 RISER-30 RISER-31 3" RD 3" ORD 4" RD 4" ORD 3" RD 3" ORD5" RD 5" ORD 4" RD 4" ORD4" RD4" ORD4" ORD4" RD4" RD4" ORD3" RD3" ORD5" RD5" ORD1/8" SLOPE1/8" SLOPE1/8" SLOPE 1/8" SLOPE 1/8" SLOPE 1/8" SLOPE 1/8" SLOPE 1/8" SLOPE 4" ORD DN IN CHASE 4" RD DN IN CHASE DOUBLE QUEEN 510 DOUBLE QUEEN ADA-M-T 512 KING STUDIO 514 KING STUDIO 516 KING STUDIO 518 KING STUDIO 520 DOUBLE QUEEN 522 DOUBLE QUEEN 524 KING STUDIO 526 EFFICIENCY 528 KING STUDIO 530 EFFICIENCY 534 DOUBLE QUEEN 536 KING STUDIO ENLARGED 538 KING STUDIO 537 DOUBLE QUEEN 535 EFFICIENCY 533 EFFICIENCY 531 EFFICIENCY 529 EFFICIENCY 527 KING STUDIO 525 KING STUDIO 523 KING STUDIO 521 KING STUDIO 519 ELEVATOR LOBBY 517 LINENES & HOUSEKEEPING 509 EFFICIENCY 507 EFFICIENCY 505 EFFICIENCY 508 KING STUDIO 504 EFFICIENCY ADA-M-T 503 KING 1-BEDROOM ENLARGED 501KING 1-BEDROOM 502 GUEST CORRIDOR 515 P-403 2 www.coffman.com 221 N. Wall Street, Suite 500 Spokane, WA 99201 ph 509.328.2994 32 MERCHANT STREET, SUITE 208 HONOLULU, HI 96813 808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 992165TH FLOOR PLUMBING PLAN P-105 FSC PROJECT NO. 21012 PERMIT SET MAY 30, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce Lane Spokane, WA 99206 (509) 919-0901 3/32" = 1'-0" 5TH FLOOR PLUMBING PLAN KEY NOTES 1 CONNECT BALCONY DRAIN TO PTAC CONDENSATE RISER. 0'6'12'24' SCALE: 3/32" = 1'-0" Revision Schedule Number Description Date 5/30/2024 GENERAL NOTES A. LOCATE PLUMBING VENTS AND EXHAUST FANS/STACKS 25'-0" MIN. FROM HVAC AIR INTAKES, AS SHOWN WITH DASHED CIRCLES ON PLAN. B. LOCATE ALL SERVICABLE EQUIPMENT A MINIMUM OF 10'-0" AWAY FROM BUILDING EDGE. A B C DC.1 E F G H J K L.1 M N P Q 9 8.1 8 7 6.1 6 5 4 3.1 3 2.1 1.1 2 CU-05 ERV-01 CU-02 3" V 3" V 3" V 3" V 3" V 3" V 3" V 3" V 3" V 3" V 3" V 3" V 3" V 3" V 3" V 3" V 3" V 3" V 3" V 3" V CU-03 RD-1 OD-1OD-1 RD-1OD-1 RD-1 OD-1 RD-1 OD-1 RD-1 OD-1 RD-1 OD-1 RD-1OD-1RD-1OD-1RD-1OD-1RD-1OD-1 8" RAD CU-04 1" G RD-1 3" V RL/RS DN RL/RS DN 1" G www.coffman.com 221 N. Wall Street, Suite 500 Spokane, WA 99201 ph 509.328.2994 32 MERCHANT STREET, SUITE 208 HONOLULU, HI 96813 808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 99216PLUMBING ROOF PLAN P-106 FSC PROJECT NO. 21012 PERMIT SET MAY 30, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce Lane Spokane, WA 99206 (509) 919-0901 0'6'12'24' SCALE: 3/32" = 1'-0" 3/32" = 1'-0" PLUMBING ROOF PLAN Revision Schedule Number Description Date 5/30/2024 D D D D WWWW D D D D WWWW A B C DC.1 E F G H J K L.1 M N P Q 9 8.1 8 7 6.1 6 5 4 3.1 3 2.1 1.1 2 FCU-215 FCU-216 FCU-213 FCU-211 FCU-212 BCU-02 3/4" D 3/4" D 3/4" D 3/4" D 3/4" D 3/4" D 3/4" D 3/4" D RL/RS UP RL/RS UP AHU-01 RL/RS UP 3/4" D RISER-10 STACK-33 STACK-1 STACK-2 STACK-3 STACK-4 STACK-5 STACK-6 STACK-7 STACK-8 STACK-9 STACK-10 STACK-11 STACK-12 STACK-13 STACK-14 STACK-15 STACK-16 STACK-17 STACK-18 STACK-19 STACK-20 STACK-21 STACK-22STACK-23 STACK-24STACK-25 STACK-26 STACK-27 STACK-28 STACK-29 STACK-30 STACK-31 STACK-32 1 2 1 1 1 1 KING STUDIO 137 KING STUDIO ADA-M-T 138 DOUBLE QUEEN 136 EFFICIENCY 134 STAIR 2 132 KING STUDIO 130OWNER'S OFFICE 127 SALES OFFICE 126 GM OFFICE 125 OPEN OFFICE 124 FOOD PREP 123 EFFICIENCY 129 EFFICIENCY 131 EFFICIENCY 133 DOUBLE QUEEN 135 LOBBY 121 MEETING ROOM 120 ELEVATOR LOBBY 117ELEV 1 111 ELEV 2 113LINEN STORAGE 109 BOH LAUNDRY 105 LINEN DISCHARGE & SORTING 107 LAUNDRY LOUNGE 112 GUEST STORAGE 118 MEN'S RESTROOM 116 WOMEN'S RESTROOM 115 MEETING STORAGE 119 FITNESS 114 WATER HEATER & FIRE 108 STAIR 1 106 ELECTRICAL 104VESTIBULE 100A POOL & SPLASH PAD 101 POOL RESTROOM 102 POOL MEP 103 MAU-01 1-1/2" D 1-1/2" DRAIN DOWN IN WALL TO FLOOR SINK GENERAL PIPING NOTES A. PLUMBING PLANS SHOW GENERAL ROUTING AND ARRANGEMENT OF PIPING. B. CONTRACTOR SHALL COORDINATE ROUTING AND SPACE REQUIREMENTS OF PIPING WITH STRUCTURAL MEMBERS AND ALL OTHER TRADES INCLUDING HVAC, FIRE PROTECTION, ELECTRICAL, AND COMMUNICATIONS/DATA. OFFSET PIPING AROUND DUCTWORK AND OTHER OBSTACLES WHERE REQUIRED. C. INDOOR CONDENSATE DRAIN PIPING SHALL BE TYPE 'L' OR 'M' COPPER OR SCHED. 40 PVC. SLOPE ALL CONDENSATE DRAIN PIPING AT 1/8" PER FOOT, MIN. D. ALL FAN COILS SHALL HAVE A BUILT-IN CONDENSATE PUMP. E. TERMINATE DRAIN STACKS AT EXTERIOR WALL WITH DOWNWARD FACING ELBOW LOCATED 18" AFF. ALL EXPOSED EXTERIOR PIPING AND FITTINGS SHALL BE STEEL PAINTED TO MATCH EXTERIOR. PROVIDE ESCUTCHEON TO TRIM PIPING AT FINISHED EXTERIOR. www.coffman.com 221 N. Wall Street, Suite 500 Spokane, WA 99201 ph 509.328.2994 32 MERCHANT STREET, SUITE 208 HONOLULU, HI 96813 808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 99216GROUND FLOOR REFRIGERANT AND CONDENSATE PIPING PLAN P-111 FSC PROJECT NO. 21012 PERMIT SET MAY 30, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce Lane Spokane, WA 99206 (509) 919-0901 3/32" = 1'-0" GROUND FLOOR REFRIGERANT AND CONDENSATE PIPING PLAN 0'6'12'24' SCALE: 3/32" = 1'-0" KEY NOTES 1 ROUTE CONDENSATE LINE DOWN WALL AND CONNECT TO SINK TAIL PIECE. 2 ROUTE RL/RS PIPING FROM BRANCH CONTROLLER (BC) TO FCU. Revision Schedule Number Description Date 5/30/2024 W/DW/DW/DW/DGENERAL PIPING NOTES A. PLUMBING PLANS SHOW GENERAL ROUTING AND ARRANGEMENT OF PIPING. B. CONTRACTOR SHALL COORDINATE ROUTING AND SPACE REQUIREMENTS OF PIPING WITH STRUCTURAL MEMBERS AND ALL OTHER TRADES INCLUDING HVAC, FIRE PROTECTION, ELECTRICAL, AND COMMUNICATIONS/DATA. OFFSET PIPING AROUND DUCTWORK AND OTHER OBSTACLES WHERE REQUIRED. C. INDOOR CONDENSATE DRAIN PIPING SHALL BE TYPE 'L' OR 'M' COPPER OR SCHED. 40 PVC. SLOPE ALL CONDENSATE DRAIN PIPING AT 1/8" PER FOOT, MIN. D. ALL FAN COILS SHALL HAVE A BUILT-IN CONDENSATE PUMP. E. TERMINATE DRAIN STACKS AT EXTERIOR WALL WITH DOWNWARD FACING ELBOW LOCATED 18" AFF. ALL EXPOSED EXTERIOR PIPING AND FITTINGS SHALL BE STEEL PAINTED TO MATCH EXTERIOR. PROVIDE ESCUTCHEON TO TRIM PIPING AT FINISHED EXTERIOR. A B C DC.1 E F G H J K L.1 M N P Q 9 8.1 8 7 6.1 6 5 4 3.1 3 2.1 1.1 2 3/4" DRAIN 3/4" DRAIN 3/4" DRAIN 3/4" DRAIN 3/4" DRAIN 3/8" RL 5/8" RS 3/4" DRAIN 3/4" DRAIN STACK-33 STACK-1 STACK-2 STACK-3 STACK-4 STACK-5 STACK-6 STACK-7 STACK-8 STACK-9 STACK-10 STACK-11 STACK-12 STACK-13 STACK-14 STACK-15 STACK-16 STACK-17 STACK-18 STACK-19 STACK-20 STACK-21 STACK-22STACK-23 STACK-24STACK-25STACK-26 STACK-27 STACK-28 STACK-29 STACK-30 STACK-31 STACK-32 1 1 1 1 1 FCU-321 FCU-324FCU-323 FCU-421 FCU-322 FCU-325 FCU-326 1 1 KING STUDIO 237 KING STUDIO ADA-M-T 238 DOUBLE QUEEN 236 EFFICIENCY 234 STAIR 2 232 KING STUDIO 230 EFFICIENCY 228 KING STUDIO 226DOUBLE QUEEN 224 DOUBLE QUEEN 222 KING STUDIO 220 KING STUDIO 218 KING STUDIO 216 KING STUDIO 214 KING STUDIO 219 KING STUDIO 221 KING STUDIO 223 KING STUDIO 225 EFFICIENCY 227 EFFICIENCY 229 EFFICIENCY 231 EFFICIENCY 233 DOUBLE QUEEN 235 GUEST CORRIDOR 215 DOUBLE QUEEN ENLARGED 212 DOUBLE QUEEN 210 LINENES & HOUSEKEEPING 209 EFFICIENCY 208 EFFICIENCY 205 ENGINEERING OFFICE & STORAGE 207 STAIR 1 206 KING STUDIO 204 EFFICIENCY ENLARGED 203 KING 1-BEDROOM ENLARGED 201KING 1-BEDROOM 202 RL/RS UP/DN TYP www.coffman.com 221 N. Wall Street, Suite 500 Spokane, WA 99201 ph 509.328.2994 32 MERCHANT STREET, SUITE 208 HONOLULU, HI 96813 808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 992162ND FLOOR REFRIGERANT AND CONDENSATE PIPING PLAN P-112 FSC PROJECT NO. 21012 PERMIT SET MAY 30, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce Lane Spokane, WA 99206 (509) 919-0901 0'6'12'24' SCALE: 3/32" = 1'-0" KEY NOTES 1 ROUTE CONDENSATE LINE DOWN WALL AND CONNECT TO SINK TAIL PIECE. 3/32" = 1'-0" 2ND FLOOR REFRIGERANT AND CONDENSATE PIPING Revision Schedule Number Description Date 5/30/2024 W/DWDMicrowaveW/DWDMicrowaveA A B B C C D C.1 E E F F G G H H J J K K L.1 L.1 M M N N P P Q Q 99 8.1 88 77 6.1 66 55 44 3.13.1 33 2.12.1 1.11.1 2 2 3/4" DRAIN 3/4" DRAIN 3/4" DRAIN 1/4" RL 1/2" RS 3/4" DRAIN 3/4" DRAIN BCU-01 STACK-33 STACK-1 STACK-2 STACK-3 STACK-4 STACK-5 STACK-6 STACK-7 STACK-8 STACK-9 STACK-10 STACK-11 STACK-12 STACK-13 STACK-14 STACK-15 STACK-16 STACK-17 STACK-18 STACK-19 STACK-20 STACK-21 STACK-22STACK-23 STACK-24STACK-25STACK-26 STACK-27 STACK-28 STACK-29 STACK-30 STACK-31 STACK-32 1 2 1 1 1 1 FCU-335FCU-334 FCU-333FCU-332 FCU-331 KING STUDIO 337 DOUBLE QUEEN 335 EFFICIENCY 333 EFFICIENCY 331 EFFICIENCY 329 EFFICIENCY 327 KING STUDIO 325 KING STUDIO 323 KING STUDIO 321 KING STUDIO 319 KING STUDIO 320 DOUBLE QUEEN 322 DOUBLE QUEEN 324 KING STUDIO 326 EFFICIENCY 328 KING STUDIO 330 EFFICIENCY 334 DOUBLE QUEEN 336 KING STUDIO ADA-M-RI 338 GUEST CORRIDOR 315 STAIR 2 332 KING STUDIO 318 KING STUDIO 316 KING STUDIO 314 DOUBLE QUEEN ENLARGED 312 DOUBLE QUEEN 310 LINENES & HOUSEKEEPING 309 EFFICIENCY 308 EFFICIENCY 307 EFFICIENCY 305 EFFICIENCY ENLARGED 303 KING 1-BEDROOM ADA-M-T 301KING 1-BEDROOM 302 KING STUDIO 304 STAIR 1 306 ELEVATOR LOBBY 317 ELEV 2 113 ELEV 1 111 RL/RS UP/DN TYP GENERAL PIPING NOTES A. PLUMBING PLANS SHOW GENERAL ROUTING AND ARRANGEMENT OF PIPING. B. CONTRACTOR SHALL COORDINATE ROUTING AND SPACE REQUIREMENTS OF PIPING WITH STRUCTURAL MEMBERS AND ALL OTHER TRADES INCLUDING HVAC, FIRE PROTECTION, ELECTRICAL, AND COMMUNICATIONS/DATA. OFFSET PIPING AROUND DUCTWORK AND OTHER OBSTACLES WHERE REQUIRED. C. INDOOR CONDENSATE DRAIN PIPING SHALL BE TYPE 'L' OR 'M' COPPER OR SCHED. 40 PVC. SLOPE ALL CONDENSATE DRAIN PIPING AT 1/8" PER FOOT, MIN. D. ALL FAN COILS SHALL HAVE A BUILT-IN CONDENSATE PUMP. E. TERMINATE DRAIN STACKS AT EXTERIOR WALL WITH DOWNWARD FACING ELBOW LOCATED 18" AFF. ALL EXPOSED EXTERIOR PIPING AND FITTINGS SHALL BE STEEL PAINTED TO MATCH EXTERIOR. PROVIDE ESCUTCHEON TO TRIM PIPING AT FINISHED EXTERIOR. www.coffman.com 221 N. Wall Street, Suite 500 Spokane, WA 99201 ph 509.328.2994 32 MERCHANT STREET, SUITE 208 HONOLULU, HI 96813 808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 992163RD FLOOR REFRIGERANT AND CONDENSATE PIPING PLAN P-113 FSC PROJECT NO. 21012 PERMIT SET MAY 30, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce Lane Spokane, WA 99206 (509) 919-0901 3/32" = 1'-0" 3RD FLOOR REFRIGERANT AND CONDENSATE PIPING PLAN 0'6'12'24' SCALE: 3/32" = 1'-0" KEY NOTES 1 ROUTE CONDENSATE LINE DOWN WALL AND CONNECT TO SINK TAIL PIECE. 2 ROUTE RL/RS PIPING FROM BRANCH CONTROLLER (BC) TO FCU. Revision Schedule Number Description Date 5/30/2024 W/DW/DW/DW/DA A B B C C D C.1 E E F F G G H H J J K K L.1 L.1 M M N N P P Q Q 99 8.1 88 77 6.1 66 55 44 3.13.1 33 2.12.1 1.11.1 2 2 3/4" DRAIN 3/4" DRAIN 3/4" DRAIN 3/4" DRAIN 3/4" DRAIN STACK-33 STACK-1 STACK-2 STACK-3 STACK-4 STACK-5 STACK-6 STACK-7 STACK-8 STACK-9 STACK-10 STACK-11 STACK-12 STACK-13 STACK-14 STACK-15 STACK-16 STACK-17 STACK-18 STACK-19 STACK-20 STACK-21 STACK-22STACK-23 STACK-24STACK-25STACK-26 STACK-27 STACK-28 STACK-29 STACK-30 STACK-31 STACK-32 1 FCU-345FCU-344 FCU-342 FCU-343 FCU-341 1 1 1 1 KING STUDIO 437 KING STUDIO ENLARGED 438DOUBLE QUEEN 436 DOUBLE QUEEN 435 EFFICIENCY 433 EFFICIENCY 431 EFFICIENCY 429 EFFICIENCY 427 KING STUDIO 425 KING STUDIO 423 KING STUDIO 421 KING STUDIO 419 KING STUDIO 420 DOUBLE QUEEN 422 DOUBLE QUEEN 424 KING STUDIO 426 EFFICIENCY 428 KING STUDIO 430 STAIR 2 432 EFFICIENCY 434 GUEST CORRIDOR 415 KING STUDIO 418 KING STUDIO 416 KING STUDIO 414 DOUBLE QUEEN ENLARGED 412 DOUBLE QUEEN 410 LINENES & HOUSEKEEPING 409 ELEVATOR LOBBY 417ELEV 1 111 ELEV 2 113 EFFICIENCY 407 EFFICIENCY 405 EFFICIENCY ADA-M-RI 403 KING 1-BEDROOM ENLARGED 401 KING 1-BEDROOM 402 KING STUDIO 404 EFFICIENCY 408 RL/RS UP/DN TYP 2 GENERAL PIPING NOTES A. PLUMBING PLANS SHOW GENERAL ROUTING AND ARRANGEMENT OF PIPING. B. CONTRACTOR SHALL COORDINATE ROUTING AND SPACE REQUIREMENTS OF PIPING WITH STRUCTURAL MEMBERS AND ALL OTHER TRADES INCLUDING HVAC, FIRE PROTECTION, ELECTRICAL, AND COMMUNICATIONS/DATA. OFFSET PIPING AROUND DUCTWORK AND OTHER OBSTACLES WHERE REQUIRED. C. INDOOR CONDENSATE DRAIN PIPING SHALL BE TYPE 'L' OR 'M' COPPER OR SCHED. 40 PVC. SLOPE ALL CONDENSATE DRAIN PIPING AT 1/8" PER FOOT, MIN. D. ALL FAN COILS SHALL HAVE A BUILT-IN CONDENSATE PUMP. E. TERMINATE DRAIN STACKS AT EXTERIOR WALL WITH DOWNWARD FACING ELBOW LOCATED 18" AFF. ALL EXPOSED EXTERIOR PIPING AND FITTINGS SHALL BE STEEL PAINTED TO MATCH EXTERIOR. PROVIDE ESCUTCHEON TO TRIM PIPING AT FINISHED EXTERIOR. www.coffman.com 221 N. Wall Street, Suite 500 Spokane, WA 99201 ph 509.328.2994 32 MERCHANT STREET, SUITE 208 HONOLULU, HI 96813 808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 992164TH FLOOR REFRIGERANT AND CONDENSATE PIPING PLAN P-114 FSC PROJECT NO. 21012 PERMIT SET MAY 30, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce Lane Spokane, WA 99206 (509) 919-0901 3/32" = 1'-0" 4TH FLOOR REFRIGERANT AND CONDENSATE PIPING PLAN 0'6'12'24' SCALE: 3/32" = 1'-0" KEY NOTES 1 ROUTE CONDENSATE LINE DOWN WALL AND CONNECT TO SINK TAIL PIECE. 2 ROUTE RL/RS PIPING FROM BRANCH CONTROLLER (BC) TO FCU. Revision Schedule Number Description Date 5/30/2024 W/DW/DW/DW/DA A B B C C D C.1 E E F F G G H H J J K K L.1 L.1 M M N N P P Q Q 99 8.1 88 77 6.1 66 55 44 3.13.1 33 2.1 1.11.1 2 3/4" DRAIN RL/RS UP TYP. 3/4" DRAIN 3/4" DRAIN 3/4" DRAIN 3/4" DRAIN STACK-33 STACK-1 STACK-2 STACK-3 STACK-4 STACK-5 STACK-6 STACK-7 STACK-8 STACK-9 STACK-10 STACK-11 STACK-12 STACK-13 STACK-14 STACK-15 STACK-16 STACK-17 STACK-18 STACK-19 STACK-20 STACK-21 STACK-22STACK-23 STACK-24STACK-25STACK-26 STACK-27 STACK-28 STACK-29 STACK-30 STACK-31 STACK-32 KING STUDIO 537 KING STUDIO ENLARGED 538 DOUBLE QUEEN 536 EFFICIENCY 534 DOUBLE QUEEN 535 EFFICIENCY 533 EFFICIENCY 531 EFFICIENCY 529 EFFICIENCY 527 KING STUDIO 525 KING STUDIO 523 KING STUDIO 521 KING STUDIO 519 KING STUDIO 520 DOUBLE QUEEN 522 DOUBLE QUEEN 524 KING STUDIO 526 GUEST CORRIDOR 515 KING STUDIO 518 KING STUDIO 516 KING STUDIO 514 DOUBLE QUEEN ADA-M-T 512 LINENES & HOUSEKEEPING 509 DOUBLE QUEEN 510 EFFICIENCY 508 EFFICIENCY 507 ELEVATOR LOBBY 517 STAIR 1 506 EFFICIENCY 505 EFFICIENCY ADA-M-T 503 KING STUDIO 504 KING 1-BEDROOM 502 CONNECTING CORRIDOR 500 KING 1-BEDROOM ENLARGED 501 EFFICIENCY 528 KING STUDIO 530 STAIR 2 532 FCU-351 1 1 1 11 FCU-355FCU-354 FCU-352 FCU-353 2 GENERAL PIPING NOTES A. PLUMBING PLANS SHOW GENERAL ROUTING AND ARRANGEMENT OF PIPING. B. CONTRACTOR SHALL COORDINATE ROUTING AND SPACE REQUIREMENTS OF PIPING WITH STRUCTURAL MEMBERS AND ALL OTHER TRADES INCLUDING HVAC, FIRE PROTECTION, ELECTRICAL, AND COMMUNICATIONS/DATA. OFFSET PIPING AROUND DUCTWORK AND OTHER OBSTACLES WHERE REQUIRED. C. INDOOR CONDENSATE DRAIN PIPING SHALL BE TYPE 'L' OR 'M' COPPER OR SCHED. 40 PVC. SLOPE ALL CONDENSATE DRAIN PIPING AT 1/8" PER FOOT, MIN. D. ALL FAN COILS SHALL HAVE A BUILT-IN CONDENSATE PUMP. E. TERMINATE DRAIN STACKS AT EXTERIOR WALL WITH DOWNWARD FACING ELBOW LOCATED 18" AFF. ALL EXPOSED EXTERIOR PIPING AND FITTINGS SHALL BE STEEL PAINTED TO MATCH EXTERIOR. PROVIDE ESCUTCHEON TO TRIM PIPING AT FINISHED EXTERIOR. www.coffman.com 221 N. Wall Street, Suite 500 Spokane, WA 99201 ph 509.328.2994 32 MERCHANT STREET, SUITE 208 HONOLULU, HI 96813 808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 992165TH FLOOR REFRIGERANT AND CONDENSATE PIPING PLAN P-115 FSC PROJECT NO. 21012 PERMIT SET MAY 30, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce Lane Spokane, WA 99206 (509) 919-0901 3/32" = 1'-0" 5TH FLOOR REFRIGERANT AND CONDENSATE PIPING PLAN 0'6'12'24' SCALE: 3/32" = 1'-0" KEY NOTES 1 ROUTE CONDENSATE LINE DOWN WALL AND CONNECT TO SINK TAIL PIECE. 2 ROUTE RL/RS PIPING FROM BRANCH CONTROLLER (BC) TO FCU. Revision Schedule Number Description Date 5/30/2024 K 7 6 EFFICIENCY 129 L-1 S-1 WC-1 SH-1 2" W UP TO L-1 ON FLOOR ABOVE 4" W DOWN TO BELOW SLAB 4" W UP IN CHASE ABOVE 2" W UP TO S-1 ON FLOOR ABOVE 1-1/4" HW UP IN CHASE ABOVE 1-1/4" CW UP IN CHASE ABOVE 2" V UP IN CHASE ABOVE 3/4" CONDENSATE DRAIN UP PTAC-1 2" UP IN WALL TO WCO 2" V UP IN CHASE ABOVE WCO C DC.1 3 2.1 2 EFFICIENCY ENLARGED 303 2" V UP IN WALL ABOVE S-1 L-1 WC-1 SH-1 2" W UP TO S-1 ON FLOOR ABOVE 4" W UP TO WC-2 ON FLOOR ABOVE 2" W UP TO L-1 ON FLOOR ABOVE 2" W UP TO SH-2 ON FLOOR ABOVE 1" CW UP & DN 3/4" HW UP & 1" HW DN 3/4" CONDENSATE DRAIN UP & DN 2" V UP IN CHASE PTAC-1 WCO 2" UP IN WALL TO WCO 2" W UP TO FD-1 4" W UP IN CHASE C DC.1 3 2.1 2 EFFICIENCY ENLARGED 203 1 1 S-1 L-1 WC-1 SH-1 4" W UP TO WC-1 ON FLOOR ABOVE 2" W UP TO SH-1 ON FLOOR ABOVE 1" CW UP & 1-1/4" CW DN 1" HW UP & 1-1/4" HW DN 3/4" CONDENSATE DRAIN UP & DN 2" V UP IN CHASE PTAC-1 2" W UP IN CHASE N 7 6 DOUBLE QUEEN 135 PTAC-1 CO 2" V UP IN CHASE 2" W UP IN CHASE 1-1/4" HW UP IN CHASE 1-1/4" CW UP IN CHASE SH-1 WC-1 L-1 S-1 2" W UP TO L-1 ABOVE 2" W UP TO L-1 ABOVE 4" W UP TO WC-1 ABOVE 2" UP IN WALL TO WCO WCO 3/4" CONDENSATE DRAIN UP A B 8.1 8 7 6.1 DOUBLE QUEEN ENLARGED 212 2" V UP & DN IN CHASE 1-1/4" HW DN & 1" UP IN CHASE 1-1/4" CW DN & 1" UP IN CHASE 4" UP & DN IN CHASE SH-1WC-1 L-1 WCO S-1 2" W UP TO L-1 ON FLOOR ABOVE 2" UP IN WALL TO WCO 2" W UP TO SH-1 ON FLOOR ABOVE 2" W UP TO S-1 ON FLOOR ABOVE A B 8.1 8 7 6.1 DOUBLE QUEEN ENLARGED 412 WCO SH-1WC-1 L-1 S-1 3/4" HW UP & 1" DN 2" V UP IN CHASE 3/4" CW UP & 1" DN 4" W DN IN CHASE 2" UP IN WALL TO WCO ON FLOOR ABOVE 2" V UP IN WALL ABOVE 2" W UP TO SH-4 ON FLOOR ABOVE 4" W UP TO WC-2 ON FLOOR ABOVE 3/4" CONDENSATE DRAIN UP & DN PTAC GENERAL NOTES A. SIZES SHOWN ON THESE PLANS ARE ACCURATE FOR THESE SPECIFIC ROOMS. FOR ROOM-SPECIFIC SIZES OF PIPES IN CHASES, SEE RISER DIAGRAMS ON SHEETS P-601 THROUGH P-605. PIPING SHOWN OUTSIDE OF PLUMBING CHASE IS TYPICAL FOR ALL ROOMS OF THE SAME LAYOUT. B. CONDENSATE RISER SERVING UPPER FLOORS TO EXIT BUILDING EXTERIOR WALL AND TERMINATE AS AN ELBOW DOWN INTO LANDSCAPING. EXPOSED PIPE SHALL BE COPPER OR STAINLESS STEEL, NO PVC. www.coffman.com 221 N. Wall Street, Suite 500 Spokane, WA 99201 ph 509.328.2994 32 MERCHANT STREET, SUITE 208 HONOLULU, HI 96813 808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 99216ENLARGED PLUMBING PLANS P-401 FSC PROJECT NO. 21012 PERMIT SET MAY 30, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce Lane Spokane, WA 99206 (509) 919-0901 1/4" = 1'-0"1 ENLARGED PLUMBING PLAN - EFFICIENCY 1/4" = 1'-0"2 ENLARGED PLUMBING PLAN - EFFICIENCY ENLARGED 1/4" = 1'-0"3 ENLARGED PLUMBING PLAN - EFFICIENCY ADA-M-RI 1/4" = 1'-0"4 ENLARGED PLUMBING PLAN - DOUBLE QUEEN 1/4" = 1'-0"5 ENLARGED PLUMBING PLAN - DOUBLE QUEEN ENLARGED 1/4" = 1'-0"6 ENLARGED PLUMBING PLAN - DOUBLE QUEEN ADA-M-T NOTE: GUEST ROOMS ON THE FIFTH FLOOR ARE SERVED FROM PIPING IN FOURTH FLOOR CEILING. THAT PIPING IS NOT SHOWN ON THESE PLANS FOR CLARITY, REFER TO RISER DIAGRAMS ON SHEETS P-601 THROUGH P-605 FOR PIPE SIZES AND CONNECTIONS, AND TO ENLARGED PLAN 2/P-403 FOR UNDERFLOOR ROUTING. 3/4" CONDENSATE DRAIN UP & DN PTAC Revision Schedule Number Description Date 5/30/2024 K L.1 9 8 KING STUDIO 130 WC-1 L-1 SH-1 S-1 4" W UP TO WC-1 ON FLOOR ABOVE 2" W UP TO L-1 ON FLOOR ABOVE 2" UP IN WALL ABOVE TO WCO 2" W UP TO SH-1 ON FLOOR ABOVE WCO 3/4" CONDENSATE DRAIN UP PTAC 2" V UP IN CHASE 1-1/4" HW UP IN CHASE 1-1/4" CW UP IN CHASE 4" W UP IN CHASE P 9 8 KING STUDIO ADA-M-T 138 4" W UP TO WC-2 ON FLOOR ABOVE 2" W UP TO L-2 ON FLOOR ABOVE 2" UP IN WALL ABOVE TO WCO 2" W UP TO SH-1 ON FLOOR ABOVE 2" V UP IN CHASE 1-1/4" HW UP IN CHASE 1-1/4" CW UP IN CHASE 4" W UP IN CHASE WCO SH-4 L-2 WC-2 S-1 PTAC 3/4" CONDENSATE DRAIN UP & DN 2" W UP TO S-1 ON FLOOR ABOVE B 2.1 1.1 2 KING 1-BEDROOM 202 4" W UP TO WC-1 ON FLOOR ABOVE 2" W UP TO L-1 ON FLOOR ABOVE 2" UP IN WALL ABOVE TO WCO 2" W UP TO SH-1 ON FLOOR ABOVE 2" V UP & DN IN CHASE 1" HW UP & 1-1/4" DN IN CHASE 1" CW UP & 1-1/4" DN IN CHASE 4" W UP IN CHASE WCO SH-1 L-1 WC-1 S-1 PTAC 3/4" CONDENSATE DRAIN UP & DN 2" W UP TO S-1 ON FLOOR ABOVE 2" W UP TO WB-1 ON FLOOR ABOVE PTAC 3/4" CONDENSATE DRAIN UP & DN C DC.1 1.1 2 KING 1-BEDROOM ENLARGED 201 4" W UP TO WC-2 ON FLOOR ABOVE 2" W UP TO L-2 ON FLOOR ABOVE 2" UP IN WALL ABOVE TO WCO 2" W UP TO SH-1 ON FLOOR ABOVE 2" V UP & DN IN CHASE 1" HW UP & 1-1/4" DN IN CHASE 1" CW UP & 1-1/4" DN IN CHASE 4" W UP IN CHASE WCOSH-1 L-1 WC-1 2" W UP TO S-2 ON FLOOR ABOVE 2" W UP TO WB-1 ON FLOOR ABOVE PTAC 3/4" CONDENSATE DRAIN UP & DN 2" W TO WB-1 2" W TO S-2 2" VENT TO FLOOR ABOVE C DC.1 1.1 2 KING 1-BEDROOM ADA-M-T 301 4" W UP TO WC-1 ON FLOOR ABOVE 2" W UP TO L-2 ON FLOOR ABOVE 2" UP IN WALL ABOVE TO WCO 2" W UP TO SH-1 ON FLOOR ABOVE 2" V UP & DN IN CHASE 3/4" HW UP & 1" DN IN CHASE 3/4" CW UP & 1" DN IN CHASE 4" W UP & DN IN CHASE WCO SH-2 L-1 WC-2 2" W UP TO S-2 ON FLOOR ABOVE 2" W UP TO WB-1 ON FLOOR ABOVE PTAC 3/4" CONDENSATE DRAIN UP & DN 2" W TO WB-1 2" W TO S-22" VENT TO FLOOR ABOVE PTAC S-2 3/4" CONDENSATE DRAIN UP & DN SH-1 WC-1 L-1 4" W4" W 2" W 2" W 4" W UP AND DOWN IN SHAFT CO 4" W UP AND DOWN IN SHAFT SLOPE 1/4" PER 12" BACK TO MAIN (TYP) 2" V UP AND DOWN IN WALL 2" V UP AND DOWN IN WALL TO S-1 (ABOVE) TO S-1 (BELOW) TO L-1 (BELOW) 2" V 2" V 2" V 2" W TO WCO ON FLOOR ABOVE GENERAL NOTES A. SIZES SHOWN ON THESE PLANS ARE ACCURATE FOR THESE SPECIFIC ROOMS. FOR ROOM-SPECIFIC SIZES OF PIPES IN CHASES, SEE RISER DIAGRAMS ON SHEETS P-601 THROUGH P-605. PIPING SHOWN OUTSIDE OF PLUMBING CHASE IS TYPICAL FOR ALL ROOMS OF THE SAME LAYOUT. B. CONDENSATE RISER SERVING UPPER FLOORS TO EXIT BUILDING EXTERIOR WALL AND TERMINATE AS AN ELBOW DOWN INTO LANDSCAPING. EXPOSED PIPE SHALL BE COPPER OR STAINLESS STEEL, NO PVC. www.coffman.com 221 N. Wall Street, Suite 500 Spokane, WA 99201 ph 509.328.2994 32 MERCHANT STREET, SUITE 208 HONOLULU, HI 96813 808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 99216ENLARGED PLUMBING PLANS P-402 FSC PROJECT NO. 21012 PERMIT SET MAY 30, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce Lane Spokane, WA 99206 (509) 919-0901 1/4" = 1'-0"1 ENLARGED PLUMBING PLAN - KING STUDIO 1/4" = 1'-0"2 ENLARGED PLUMBING PLAN - KING STUDIO ADA-M-T 1/4" = 1'-0"4 ENLARGED PLUMBING PLAN - KING STUDIO 1 BEDROOM 1/4" = 1'-0"5 ENLARGED PLUMBING PLAN - 1 BEDROOM ENLARGED 1/4" = 1'-0"6 ENLARGED PLUMBING PLAN - KING 1 BEDROOM ADA-M-T 3 TYPICAL TOILET ROOM WASTE AND VENT PIPING Revision Schedule Number Description Date 5/30/2024 B 5 4 1-1/2" HWC (LOW TEMP) 2-1/2" HW (165F) TO LAUNDRY FS-1 WH-1 WH-2 WH-3 WH-46" CW DN 1" G TO WH (TYP) 3" G DN WATER SOFTENER (TYP 2)2" V DN RISER 6 SERVING FLOOR ABOVE 1" HW (140F) TO KITCHEN 3/4" HWC (140F) 2" G 4" HW 6" CW 3" G 6" CW 6" CW HWC TO WHs - SEE 1/P-502 RPBP FS-1 FIRE HEADER A B 8.1 8 7 6.1 NOTE: GUEST ROOMS ON THE FIFTH FLOOR ARE SERVED FROM HOT & COLD WATER PIPING IN FOURTH FLOOR CEILING. THAT PIPING IS SHOWN HALF-WIDTH ON THIS PLAN FOR CLARITY. REFER TO RISER DIAGRAMS ON SHEETS P-601 THROUGH P-605 FOR PIPE SIZES AND CONNECTIONS. S-1 SH-4 WC-2 L-2 3" VTR 3/4" HW DN 3/4" CW DN 3/4" CONDENSATE DRAIN DN www.coffman.com 221 N. Wall Street, Suite 500 Spokane, WA 99201 ph 509.328.2994 32 MERCHANT STREET, SUITE 208 HONOLULU, HI 96813 808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 99216ENLARGED WATER HEATER ROOM P-403 FSC PROJECT NO. 21012 PERMIT SET MAY 30, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce Lane Spokane, WA 99206 (509) 919-0901 3/8" = 1'-0"1 ENLARGED WATER HEATER ROOOM PLAN 1/4" = 1'-0"2 5TH FLOOR PLUMBING PLAN SERVED FROM 4TH FLOOR Revision Schedule Number Description Date 5/30/2024 6" DOMESTIC WATER SUPPLY PRESSURE GAUGE FULL PORT BALL VALVE 6" STRAINER W/ BLOWDOWN, WATTS MODEL 0825214 P P 6" RPBP, WATTS MODEL LF957,OSY 6" DOMESTIC WATER TO FIXTURES 6" D ROUTE TO FLOOR SINK P 6" PRV WATTS MODEL LFM115 150 NOTE: FOR TRAPEZE HANGER TAKE SPACING OF SMALLEST SIZE ON TRAPEZE. MAXIMUM PIPE/TUBING SUPPORT SPACING TUBING 5 FT NOM. SIZE PIPE 7 6 8 10 9 1110 12 1312 14 -16 1614 17 2219 TO 1000 LB. UNIFORM LOAD TRAPEZE HANGER FOR UP PROVIDE INSULATION SHIELD AND INSERT FOR ALL PIPING (8" MIN.) SIDE VIEW 1 5/8" 12 GAGE CHANNEL OR 2"X2"X1/4" ANGLE SPACING ON 36" MAX. HANGER RODS WITH 1/2" DIA. EACH CHANNEL BAND 8 10645322 1/21 1/211 1/4IN. FT. FT. THRU 3/4 7 7 7 981" MAX.ADJUSTABLE CLEVIS HANGER TYPE 43 - SEE SPECIFICATIONS PROVIDE HIGH COMPRESSIVE STRENGTH INSULATION (9 PCF MIN. DENSITY) UNDER INSULATION SHIELD TYPE 1 - SEE SPECIFICATIONS ADJUSTABLE CLEVIS HANGER HANGER ROD INSULATION SHIELD AT HANGER INSULATION (VAPOR BARRIER TYPE IS REQUIRED FOR LOW TEMPERATURE PIPE) 14"SQ.x4" DEEP CONCRETE PAD, TROWEL SMOOTH AND EDGE 1/8" BEND WASTE LINE MAY EXTEND AS WASTE OR VENT WALL PLUGGED TEE W/ CLEANOUT FINISHED FLOOR 1/8" BEND WASTE LINE FINISHED FLOOR BALANCE OF PIPING SAME AS CLEANOUT TO GRADE FINISHED GRADE WASTE LINE, LENGTH TO SUIT 1/8" BEND IF CLEANOUT OCCURS AT END OF LINE CHROME WALLCOVER & SCREW, USE TAMPER PROOF SCREWS INSIDE BUILDING 1/8" BEND IF CLEANOUT OCCURS AT END OF LINE CLEANOUT AND ACCESS COVER. TOP OF COVER TO BE FLUSH W/ TOP OF FLOOR 1/8" BEND BALANCE OF PIPING SAME AS WALL CLEANOUT DRAIN PIPE CAULK INSIDE CONNECTION GAS TIGHT PLUG SCORIATED SECURED CAST IRON COVER CONCRETE SLAB ON GRADE FLOOR SLOPE, SEE ARCH. VAPOR BARRIER ROCK BASE FLOOR FINISH WHERE OCCURS FINISHED FLOOR FLOOR DRAIN WITH ADJUSTABLE HEIGHT STRAINER RADIUS ALL AROUND FOR DISHED RECESS FLOOR DRAIN SEALANT ALL AROUND 1'-0" SLOPE IN ADA ACCESSIBLE RESTROOMS NOT TO EXCEED 1 IN 50. WATERPROOF MEMBRANE, WHERE SPECIFIED (SEE ARCH.) CLAMP MEMBRANE TIGHTLY INTO DRAIN COLLAR 1 1 FLOOR SINK SEALANT ALL AROUND FINISHED FLOOR FLOOR FINISH WHERE OCCURS SECOND LAYER 4'-0" SQUARE VAPOR BARRIER TIGHTLY FITTED AROUND PENETRATION AND SEALED WITH TAPE COMPACTED FILL VAPOR BARRIER CONCRETE SLAB ON GRADE TYPICAL LAVATORY CONDENSATE DRAIN DOWN IN WALL CHROME PLATE ESCUTCHEON COPPER DRAIN RUBBER HOSE AND STAINLESS STEEL HOSE CLAMP P-TRAP NOTE: ADJUST ROUGH- IN HEIGHT AS REQUIRED BRANCH TAIL PIECE (WALL HUNG LAV SHOWN. CONDENSATE DRAIN PIPING SIMILAR FOR COUNTER TOP.) FAN COIL 3/4" PUMPED CONDENSATE LINE CONDENSATE COLLECTION HEADER SLOPED AT 1% MIN. OPEN VENT AT UPPER END OF LINE 1"SEE PLANS FOR PIPE SIZING MANUFACTURER PROVIDED FLEXIBLE HOSE CONNECTION MAX HEIGHT =24" NOTE: FAN COIL HAS AN INTERNAL CONDENSATE PUMP 3/4" HUBLESS CAST IRON UNDERDECK CLAMP RIGID INSULATION ROOF MEMBRANE EXTENSION INSULATED ROOF DRAIN LEADER SUMP RECEIVER ROOF DECK DOMED STRAINER NO-HUB COUPLING OVERFLOW STORM DRAIN 90° ELBOW LENGTH AS REQUIRED OVERFLOW NOZZLE WITH WALL FLANGE DS-1 18" MIN. WHEN LOCATED AT GRADE OUTSIDE FINISH SURFACE FLOOR PROVIDE BRONZE BIRD SCREEN. SLIP INTO DOWNSPOUT NOZZLE OPENING. 2" FINISHED FLOOR REMOVABLE GRATE W/ SUPPORT AT SUMP. NOTCH FOR PIPING AND ELECTRICAL SP-1 / 2 W/ FLOATS AND OIL SENSORELEVATOR SUMP SLEEVE AND SEAL AT PENETRATIONS, TYP.36" MIN.LOCATE PIPE LOOP IN WALL WALL LAUNDRY TROUGH DEHUMIDIFIER POOL AUT. CHEMICAL FEEDER AUX. POOL HEATER POOL FILTER AUXILIARY PUMP AUXILIARY PUMP DEHUMIDIFIER FM FM BRINE TANK WATER SOFTENER NOTES: 1.UNIONS SHOULD BE LOCATED ON INLET AND OUTLET CONNECTIONS OF CONTROL VALVE TO FACILITATE SERVICING. 2.THE USE OF DISSIMILAR METALS IN A PIPING SYSTEM IS NOT RECOMMENDED. WHERE DISSIMILAR METALS MUST BE CONNECTED IN A WATER SYSTEM, THE USE OF NONCONDUCTIVE (DIELECTRIC) FITTING MAY REDUCE GALVANIC CORROSION. 3.PROVIDE AN AIR GAP OF AT LEAST FOUR TIMES THE DIAMETER OF THE DRAIN PIPE OR CONFORM TO LOCAL SANITATION CODES. BYPASS VALVE (NORMALLY CLOSED) HARD WATER INLET SOFT WATER OUTLET MANUAL INLET VALVE MANUAL OUTLET VALVE CONTROLLER WATER SOFTENER COUNTERTOP GARBAGE DISPOSER DRAIN PIPING TO SANITARY SYSTEM DISHWASHER DRAIN HOSE SECURE HOSE TO DISPOSER WITH CLAMP AIR GAP FITTING DISHWASHER SINK www.coffman.com 221 N. Wall Street, Suite 500 Spokane, WA 99201 ph 509.328.2994 32 MERCHANT STREET, SUITE 208 HONOLULU, HI 96813 808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 99216PLUMBING DETAILS P-501 FSC PROJECT NO. 21012 PERMIT SET MAY 30, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce Lane Spokane, WA 99206 (509) 919-0901 NTS1WATER SERVICE ENTRY NTS8TYPICAL PIPE HANGER NTS5CLEANOUT DETAILS NTS6FLOOR DRAIN SLAB ON GRADE NTS7FLOOR SINK - SLAB ON GRADE NTS4CONDENSATE DRAIN CONNECTION NTS3FAN COIL CONDENSATE PIPING NTS10DOMED ROOF DRAIN NTS11OVERFLOW NOZZLE NTS13ELEVATOR SUMP PUMP DETAIL NTS12POOL HEATING SCHEMATIC FOR DEHUMIDIFIERS NTS9WATER SOFTENER INSTALLATION NTS2GUEST ROOM DISHWASHER WASTE DETAIL Revision Schedule Number Description Date 5/30/2024 RECIRC PUMP. BALANCE VALVE SET FOR 23.5 GPM CHECK VALVE.5" PVC VENT4" PVC INTAKELINE SIZE SUPPLY 4" COLD WATER TO SYSTEM 2" DCW P&T RELIEF VALVE TO FLOOR DRAIN DRAIN VALVE WITH THREADED HOSE CONNECTION. UNION GAS COCK DIRT LEG GAS SUPPLY SHUT-OFF DIELECTRIC UNIONS WATER HEATER WATER HEATER WH WH GGASME RATED EXTROL THERMAL EXPANSION ABSORBER TANK EXTROL NO, ST-120VC 1" DRAIN TO FLOOR DRAIN 2"MIN 2"MIN 4" (120°) HOT WATER TO SYSTEM 1-1/2" (120°) HOT WATER RE-CIRC LINE 2.5" (165 F) HOT WATER TO LAUNDRY CP-1 MV-1 2" DCW WATER HEATER WH G1 2 4 2" HOT WATER TO SYSTEM FLOOR DRAIN WATER HEATER WH G3 FLOOR DRAIN FLOOR DRAIN FLOOR DRAIN 2" DHW4" CWMV-2 1" HWET-1 4" HW 1" CW RECIRC PUMP. BALANCE VALVE 3 GPM CHECK VALVE. CP-2 3/4" (140F) HOT WATER FROM KITCHEN RE-CIRC LINE ARMSTRONG BRAIN MIXING VALVE ARMSTRONG BRAIN MIXING VALVE 1" (140°) HOT WATER TO KITCHEN END VIEW CLEVIS RING PIPE SIDE VIEW PIPE 4 1 4 3 1 4 3 4 NOTES HANGER RODS WITH STIFFENERS. ANGLE IRON OR MANUFACTURED STRUT CROSS MEMBER. RIGID BRACE (SHOWN) OR MULTIPLE CABLE BRACES. SEE STRUCTURAL FOR ANCHORAGE. 1 2 3 4 6" DRIP LEG WITH CAP CONNECTION TO EQUIPMENT CERTIFIED GAS FLEX LINE GAS SUPPLY LINE G GAS SUPPLY LINE CONNECTION TO EQUIPMENT CERTIFIED GAS FLEX LINE 6" DRIP LEG WITH CAP LISTED GAS VALVE UNION PIPE REDUCER, IF REQUIRED UNION GLISTED GAS VALVE PIPING FROM ABOVE SUPPLY FROM ABOVE HORIZONTAL SUPPLY VERTICAL OFFSET FOR DRIP LEG GAS PRESSURE REGULATOR, SIZE FOR SPECIFIC EQUIPMENT INLET PRESSURE REQUIREMENTS 1/4" TEST PLUG, CAPPED (TYP. 2) GAS PRESSURE REGULATOR, SIZE FOR SPECIFIC EQUIPMENT INLET PRESSURE REQUIREMENTS 1/4" TEST PLUG, CAPPED (TYP. 2)FLOW FROM MAIN NOT ACCEPTABLE ACCEPTABLE ACCEPTABLE FLOW FROM MAIN BRANCH CONNECTION BRANCH CONNECTION BRANCH CONNECTION FLOW FROM MAIN BRANCH CONNECTIONBRANCH CONNECTION REMOVABLE SHEET METAL COUNTERFLASHING SHEET METAL FLASHING RECEIVER SHEET METAL OR FLEX-TUBE COLLAR, SEAL AROUND PIPING WITH SILICONE CAULK SLOPE PIPES DOWN AND AWAY FROM HOOD INSULATE VOID TO PREVENT CONDENSATION SHEET METAL ENCLOSURE-CROSSBREAK OR SLOPE FOR DRAINAGE FASTENERS APPROX. 8" O.C. 6" 4" MIN. 4" CLEARANCE FROM PIPE TO TOP OF CURB; MIN. 2" BETWEEN PIPES10"NOMINAL FLASHINGHEIGHTWOOD NAILERS INSTALLED WITH BOND BREAKERS AND FASTENED AS SPECIFIED OR REQUIRED BY CODE OR INDUSTRY STANDARDS TO RESIST DESIGN LOADS AND CORROSION OF STEEL DECKING, FASTENERS AND METAL EDGING. THERMAL INSULATION, COVERBOARD AND ROOFING PLIES APPLIED TO DECK AS SPECIFIED OR REQUIRED HIGH-DOMED, CAPPED, GASKETED FASTENERS (APPROX. 18" O.C., MINIMUM TWO FASTENERS PER SIDE) FLASHING SHEETS, EXTEND TO A MIN. HEIGHT OF 8" ROOF MEMBRANE SHEETS, EXTEND 2" MIN. ABOVE TOP OF CANT NOTE: THIS DETAIL MAY NOT EXACTLY REPRESENT THE CONSTRUCTION OR TYPE OF MATERIALS CURRENTLY INSTALLED. CONTRACTOR SHALL USE THIS DETAIL AS A GUIDE IN CONJUNCTION WITH ROOF MANUFACTURER'S FLASHING INSTRUCTIONS. NOTE: CONTRACTOR MAY USE RPS PIPE PORTAL SYSTEM (CURB, COVER, CAP, AND CLAMPS) IN LIEU OF FABRICATED SYSTEM SHOWN. INSTALL PER MFRS INSTRUCTIONS. NOTES: 1. PROVIDE ANCHORS ONLY WHERE SHOWN ON DRAWINGS. 2. EXTEND SLEEVE ABOVE FLOOR WHERE SPECIFIED. BOLT (TYPICAL) FLOOR SLAB BACKING MATERIAL AND FIRE- STOPPING (RATED FLOORS) OR SILICONE CAULK (NON- RATED FLOORS) BOLT PIPE PIPE SLEEVE WHERE SPECIFIED RISER CLAMP RISER PIPE SLEEVE, WHERE SPECIFIED RISER CLAMP. BOTTOM CLAMP REQUIRED AT ANCHOR POINTS ONLY. ELEVATION PLAN RISER CLAMP GAS WATER HEATER 120°F DOMESTIC HOT WATER SUPPLY DOMESTIC HOT WATER RETURN COLD WATER T T AITANK DISCHARGE TEMPERATURE AI120°F SUPPLY TEMPERATURE DI DO START / STOP STATUS T AI RETURN TEMPERATURE www.coffman.com 221 N. Wall Street, Suite 500 Spokane, WA 99201 ph 509.328.2994 32 MERCHANT STREET, SUITE 208 HONOLULU, HI 96813 808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 99216PLUMBING DETAILS P-502 FSC PROJECT NO. 21012 PERMIT SET MAY 30, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce Lane Spokane, WA 99206 (509) 919-0901 NTS1WATER HEATER DETAIL NTS4SEISMIC BRACING FOR GAS PIPING NTS5NATURAL GAS EQUIP. CONNECTION NTS6TEES FOR COMBINED FLOW DETAIL NTS2PIPE THROUGH ROOF NTS7SUPPORT ANCHOR FOR PIPE RISERS NTS3GAS WATER HEATER CONTROL DIAGRAM Revision Schedule Number Description Date 5/30/2024 ROOF 5th FLOOR 4th FLOOR 3rd FLOOR 2nd FLOOR S-1 L-1 SH-1 WC-1WB-1 2"2" 3" 4"4" 4" 4"2" L-1 SH-4 WC-1 S-1 WB-12"1-1/2"2"2"1-1/2"2"2"2"2"2"4"4"4"4"3"3"3"3"4"4"3"3"S-1 L-1 SH-1 WC-1 2" 3" 4"4" 3" 2" WC-1 SH-1 L-1 S-11-1/2"2"2"1-1/2"2"2"2"2"3"3"S-1 L-1 SH-1 WC-1 2" 3" 4"4" 3" 2" WC-1 SH-1 L-1 S-11-1/2"2"2"1-1/2"2"2"2"2"4"4"2"2"S-1 L-1 SH-1 WC-1 2" 3" 4"4" 3" 2" WC-1 SH-1 L-1 S-11-1/2"2"2"1-1/2"2"2"2"2"4"4"2"2"S-1 L-1 SH-1 WC-1 2" 3" 4"4" 3" 2" WC-1 SH-1 L-1 S-11-1/2"2"2"1-1/2"2"2"2"2"4"4"GROUND FLOOR UNDERFLOOR S-1 L-1 SH-1 WC-1WB-1 2"2" 3" 4"4" 3" 2"2" WC-1 SH-1 L-1 S-1 WB-12"1-1/2"2"2"1-1/2"2"2"2"2"2"4"4"S-1 L-1 SH-1 WC-1WB-1 2"2" 3" 4"2"1-1/2"2"2"2"4"3"3"2"2"S-1 L-1 SH-1 WC-1WB-1 2"2" 3" 4"2"1-1/2"2"2"2" 4" 3" 2"2" WC-1 SH-1 L-1 S-1 WB-12"1-1/2"2"2"2"4"4" 3" 2"2" WC-1 SH-1 L-1 S-1 WB-12"1-1/2"2"2"2" RISER-1 RISER-2 RISER-3 RISER-64"4"3"3"4" 3" 2" WC-1 SH-1 L-1 S-12"1-1/2"2"2"3"3"4" 3" 2" WC-1 SH-1 L-1 S-12"1-1/2"2"2"4"4"3"3"S-1 L-1 SH-1 WC-1 2" 3" 4"4" 3" 2" WC-1 SH-1 L-1 S-11-1/2"2"2"1-1/2"2"2"2"2"4"4"2"2"S-1 L-1 SH-1 WC-1 2" 3" 4"4" 3" 2" WC-1 SH-1 L-1 S-11-1/2"2"2"1-1/2"2"2"2"2"4"4"RISER-4 RISER-5 4"3"4" 3" 2" WC-1 SH-1 L-1 S-12"1-1/2"2"2"3"4" 3" 2" WC-1 SH-1 L-1 S-12"1-1/2"2"2"4"3"4" 3" 2" WC-1 SH-1 L-1 S-12"1-1/2"2"2"4"RISER-7 4"4"3"3"S-1 L-1 SH-1 WC-1 2" 3" 4"4" 3" 2" WC-1 SH-1 L-1 S-11-1/2"2"2"1-1/2"2"2"2"2"3"3"S-1 L-1 SH-1 WC-1 2" 3" 4"4" 3" 2" WC-1 SH-1 L-1 S-11-1/2"2"2"1-1/2"2"2"2"2"4"4"2"3"S-1 L-1 SH-1 WC-1 2" 3" 4"4" 3" 2" WC-1 SH-1 L-1 S-11-1/2"2"2"1-1/2"2"2"2"2"4"4"2"3"S-1 L-1 SH-1 WC-1 2" 3" 4"4" 3" 2" WC-1 SH-1 L-1 S-11-1/2"2"2"1-1/2"2"2"2"2"4"4"RISER-8 RISER-9 4"3"S-1 L-1 SH-1 WC-1 2" 3" 4"1-1/2"2"2"2"3"S-1 L-1 SH-1 WC-1 2" 3" 4"1-1/2"2"2"2"4"2"S-1 L-1 SH-1 WC-1 2" 3" 4"1-1/2"2"2"2"4"2"S-1 L-1 SH-1 WC-1 2" 3" 4"1-1/2"2"2"2"4"RISER-10 4"3"S-1 L-1 SH-1 WC-1 2" 3" 4"1-1/2"2"2"2"3"S-1 L-1 SH-1 WC-1 2" 3" 4"1-1/2"2"2"2"4"2"S-1 L-1 SH-1 WC-1 2" 3" 4"1-1/2"2"2"2"4"2"S-1 L-1 SH-1 WC-1 2" 3" 4"1-1/2"2"2"2"4"RISER-11 WCO WCO WCO WCO WCO WCO WCO WCO WCO WCO WCO WCO WCO WCO WCO WCO WCO WCO WCO WCO WCO WCO WCO WCO WCO WCO WCO WCO WCO WCO WCO WCO WCO WCOWCO WCO WCO WCO WCO WCO WCO 2" 4"4" 4" 2" L-1SH-2WC-1S-1WB-1 2"1-1/2"2"WCO 2" 4"4"4"2" L-1SH-4WC-1S-1WB-1 2"1-1/2"2"WCO 2" BOH FIXTURES BOH FIXTURES3"3"3"2" FD-1 5th FLOOR 4th FLOOR 3rd FLOOR 2nd FLOOR 4"4"3"3"S-1 L-1 SH-1 WC-1 2" 3" 4"4" 3" 2" WC-1 SH-1 L-1 S-11-1/2"2"2"1-1/2"2"2"2"2"3"3"S-1 L-1 SH-1 WC-1 2" 3" 4"4" 3" 2" WC-1 SH-1 L-1 S-11-1/2"2"2"1-1/2"2"2"2"2"4"4"2"2"S-1 L-1 SH-1 WC-1 2" 3" 4"4" 3" 2" WC-1 SH-1 L-1 S-11-1/2"2"2"1-1/2"2"2"2"2"4"4"2"2"S-1 L-1 SH-1 WC-1 2" 3" 4"4" 3" 2" WC-1 SH-1 L-1 S-11-1/2"2"2"1-1/2"2"2"2"2"4"4"RISER-12 RISER-13 4"4"3"3"S-1 L-1 SH-3 WC-1 2" 3" 4"4" 3" 2" WC-1 SH-3 L-1 S-11-1/2"2"2"1-1/2"2"2"2"2"3"3"S-1 L-1 SH-3 WC-1 2" 3" 4"4" 3" 2" WC-1 SH-3 L-1 S-11-1/2"2"2"1-1/2"2"2"2"2"4"4"2"2"S-1 L-1 SH-3 WC-1 2" 3" 4"4" 3" 2" WC-1 SH-3 L-1 S-11-1/2"2"2"1-1/2"2"2"2"2"4"4"2"2"S-1 L-1 SH-3 WC-1 2" 3" 4"4" 3" 2" WC-1 SH-3 L-1 S-11-1/2"2"2"1-1/2"2"2"2"2"4"4"RISER-15 RISER-164"3"4" 3" 2" WC-1 SH-1 L-1 S-12"1-1/2"2"2"3"4" 3" 2" WC-1 SH-1 L-1 S-12"1-1/2"2"2"4"2"4" 3" 2" WC-1 SH-1 L-1 S-12"1-1/2"2"2"4"2"4" 3" 2" WC-1 SH-1 L-1 S-12"1-1/2"2"2"4"RISER-14 4"4"3"3"S-1 L-1 SH-1 WC-1 2" 3" 4"4" 3" 2" WC-1 SH-1 L-1 S-11-1/2"2"2"1-1/2"2"2"2"2"3"3"S-1 L-1 SH-1 WC-1 2" 3" 4"4" 3" 2" WC-1 SH-1 L-1 S-11-1/2"2"2"1-1/2"2"2"2"2"4"4"2"2"S-1 L-1 SH-1 WC-1 2" 3" 4"4" 3" 2" WC-1 SH-1 L-1 S-11-1/2"2"2"1-1/2"2"2"2"2"4"4"2"2"S-1 L-1 SH-1 WC-1 2" 3" 4"4" 3" 2" WC-1 SH-1 L-1 S-11-1/2"2"2"1-1/2"2"2"2"2"4"4"RISER-17 RISER-18 4"4"3"3"S-1 L-1 SH-1 WC-1 2" 3" 4"4" 3" 2" WC-1 SH-1 L-1 S-11-1/2"2"2"1-1/2"2"2"2"2"3"3"S-1 L-1 SH-1 WC-1 2" 3" 4"4" 3" 2" WC-1 SH-1 L-1 S-11-1/2"2"2"1-1/2"2"2"2"2"4"4"2"2"S-1 L-1 SH-1 WC-1 2" 3" 4"4" 3" 2" WC-1 SH-1 L-1 S-11-1/2"2"2"1-1/2"2"2"2"2"4"4"2"2"S-1 L-1 SH-1 WC-1 2" 3" 4"4" 3" 2" WC-1 SH-1 L-1 S-11-1/2"2"2"1-1/2"2"2"2"2"4"4"RISER-19 RISER-20 4"4"3"3"S-1 L-1 SH-1 WC-1 2" 3" 4"4" 3" 2" WC-1 SH-1 L-1 S-11-1/2"2"2"1-1/2"2"2"2"2"3"3"S-1 L-1 SH-1 WC-1 2" 3" 4"4" 3" 2" WC-1 SH-1 L-1 S-11-1/2"2"2"1-1/2"2"2"2"2"4"4"2"3"S-1 L-1 SH-1 WC-1 2" 3" 4"4" 3" 2" WC-1 SH-1 L-1 S-11-1/2"2"2"1-1/2"2"2"2"2"4"4"2"3"S-1 L-1 SH-1 WC-1 2" 3" 4"4" 3" 2" WC-1 SH-1 L-1 S-11-1/2"2"2"1-1/2"2"2"2"2"4"4"RISER-21 RISER-22 ROOF GROUND FLOOR UNDERFLOOR WCO WCO WCO WCO WCO WCO WCO WCO WCO WCO WCO WCO WCO WCO WCO WCO WCO WCO WCO WCOWCO WCO WCO WCO WCO WCO WCO WCO WCO WCO WCO WCO WCO WCO WCO WCO WCO WCO WCO WCO WCO WCO WCO WCO BF-12"3"KITCHEN FIXTURES www.coffman.com 221 N. Wall Street, Suite 500 Spokane, WA 99201 ph 509.328.2994 32 MERCHANT STREET, SUITE 208 HONOLULU, HI 96813 808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 99216WASTE AND VENT RISER DIAGRAM P-601 FSC PROJECT NO. 21012 PERMIT SET MAY 30, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce Lane Spokane, WA 99206 (509) 919-0901 NTS1WASTE & VENT RISER DIAGRAM 1 NTS2WASTE & VENT RISER DIAGRAM 2 Revision Schedule Number Description Date 5/30/2024 ROOF 5th FLOOR 4th FLOOR 3rd FLOOR 2nd FLOOR GROUND FLOOR UNDERFLOOR 3"4" 3" 2" WC-1 SH-1 L-1 S-12"1-1/2"2"2"3"4" 3" 2" WC-1 SH-1 L-1 S-12"1-1/2"2"2"4"3"4" 3" 2" WC-1 SH-1 L-1 S-12"1-1/2"2"2"4"2"4" 3" 2" WC-1 SH-1 L-1 S-12"1-1/2"2"2"4"RISER-23 4"4"3"3"S-1 L-1 SH-1 WC-1 2" 3" 4"4" 3" 2" WC-1 SH-1 L-1 S-11-1/2"2"2"1-1/2"2"2"2"2"3"3"S-1 L-1 SH-1 WC-1 2" 3" 4"4" 3" 2" WC-1 SH-1 L-1 S-11-1/2"2"2"1-1/2"2"2"2"2"4"4"3"3"S-1 L-1 SH-1 WC-1 2" 3" 4"4" 3" 2" WC-1 SH-1 L-1 S-11-1/2"2"2"1-1/2"2"2"2"2"4"4"2"2"S-1 L-1 SH-1 WC-1 2" 3" 4"4" 3" 2" WC-1 SH-1 L-1 S-11-1/2"2"2"1-1/2"2"2"2"2"4"4"RISER-24 RISER-25 4"4" 3" 2" WC-1 SH-1 L-12"2"4"S-1 L-1 SH-1 WC-1 2" 3" 4"4" 3" 2" WC-1 SH-1 L-1 S-11-1/2"2"2"1-1/2"2"2"2"2"4"4"3"3"S-1 L-1 SH-1 WC-1 2" 3" 4"4" 3" 2" WC-1 SH-3 L-1 S-11-1/2"2"2"1-1/2"2"2"2"2"3"3"S-1 L-1 SH-1 WC-1 2" 3" 4"4" 3" 2" WC-1 SH-3 L-1 S-11-1/2"2"2"1-1/2"2"2"2"2"4"4"3"3"S-1 L-1 SH-1 WC-1 2" 3" 4"4" 3" 2" WC-1 SH-3 L-1 S-11-1/2"2"2"1-1/2"2"2"2"2"4"4"2"2"S-1 L-1 SH-1 WC-1 2" 3" 4"4" 3" 2" WC-1 SH-3 L-1 S-11-1/2"2"2"1-1/2"2"2"2"2"4"4"RISER-26 RISER-27 S-1 L-1 SH-1 WC-1 2" 3" 4"4" 3" 2" WC-1 SH-3 L-1 S-11-1/2"2"2"1-1/2"2"2"2"2"4"4"3"3"S-1 L-1 SH-1 WC-1 2" 3" 4"4" 3" 2" WC-1 SH-1 L-1 S-11-1/2"2"2"1-1/2"2"2"2"2"3"3"S-1 L-1 SH-1 WC-1 2" 3" 4"4" 3" 2" WC-1 SH-1 L-1 S-11-1/2"2"2"1-1/2"2"2"2"2"4"4"3"3"S-1 L-1 SH-1 WC-1 2" 3" 4"4" 3" 2" WC-1 SH-1 L-1 S-11-1/2"2"2"1-1/2"2"2"2"2"4"4"2"2"S-1 L-1 SH-1 WC-1 2" 3" 4"4" 3" 2" WC-1 SH-1 L-1 S-11-1/2"2"2"1-1/2"2"2"2"2"4"4"RISER-28 RISER-29 S-1 L-1 SH-1 WC-1 2" 3" 4"4" 3" 2" WC-1 SH-1 L-1 S-11-1/2"2"2"1-1/2"2"2"2"2"4"4"3"3"S-1 L-1 SH-1 WC-1 2" 3" 4"4" 3" 2" WC-1 SH-1 L-1 S-11-1/2"2"2"1-1/2"2"2"2"2"3"3"S-1 L-1 SH-1 WC-1 2" 3" 4"4" 3" 2" WC-1 SH-1 L-1 S-11-1/2"2"2"1-1/2"2"2"2"2"4"4"3"3"4" 3" 2" WC-1 SH-1 L-1 S-12"1-1/2"2"2"4"4"2"2"4" 3" 2" WC-1 SH-1 L-1 S-12"1-1/2"2"2"4"4"RISER-30 RISER-31 4" 3" 2" WC-1 SH-1 L-1 S-12"1-1/2"2"2" 4"3"2" L-1SH-2WC-1S-1 2"1-1/2"2"2" 4"3"2" L-1SH-4WC-1S-1 2"1-1/2"2"2" 4"3"2" L-1SH-4WC-1S-1 2"1-1/2"2"2"2"2"2"2"2"2"WCOWCO WCO WCO WCO WCO WCO WCO WCO WCO WCO WCO WCO WCO WCO WCO WCO WCO WCO WCO WCO WCO WCO WCO WCO WCO WCO WCO WCO WCO WCO WCO WCO WCO WCO WCO WCO WCO WCO WCO WCO WCO WCO WCO WCO 2"www.coffman.com 221 N. Wall Street, Suite 500 Spokane, WA 99201 ph 509.328.2994 32 MERCHANT STREET, SUITE 208 HONOLULU, HI 96813 808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 99216WASTE AND VENT RISER DIAGRAM P-602 FSC PROJECT NO. 21012 PERMIT SET MAY 30, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce Lane Spokane, WA 99206 (509) 919-0901 NTS1WASTE & VENT RISER DIAGRAM 3 Revision Schedule Number Description Date 5/30/2024 ROOF 5th FLOOR 4th FLOOR 3rd FLOOR 2nd FLOOR GROUND FLOOR UNDERFLOOR RISER-1 RISER-2 WB-1 L-1 WC-1 SH-1S-11/2"1/2"1/2"1/2"1/2"1/2"1/2"1/2"1-1/4"1-1/4"1/2" 1/2" 3/4" 1/2"3/4" L-1WC-1SH-1 1/2"1/2"1/2"1/2"1/2"1/2"1/2"1/2"1-1/4"1-1/4"1/2" 1/2" 3/4" 1/2"3/4" WB-1 L-1 WC-1 SH-1S-11/2"1/2"1/2"1/2"1/2"1/2"1/2"1/2"1"1"1/2" 1/2" 3/4" 1/2"3/4" L-1WC-1SH-4 1/2"1/2"1/2"1/2"1/2"1/2"1/2"1/2"1"1"1/2" 1/2" 3/4" 1/2"3/4" WB-1 L-1 WC-1 SH-1S-11/2"1/2"1/2"1/2"1/2"1/2"1/2"1/2"1/2"3/4"1/2" 1/2" 3/4" 1/2" 3/4" 3/4" 3/4" S-1L-1WC-1SH-1 WB-11/2"1/2"1/2"1/2"1/2"1/2"1/2"1/2"1/2"3/4"1/2" 1/2" 3/4" 1/2" 3/4" 3/4" 3/4" WB-1 L-1 WC-1 SH-1S-1 1"1"1/2" 1/2" 1/2" 1/2" 3/4" 1/2"3/4" 3/4"3/4"1/2"1/2"1/2"1/2"1/2"1/2"1/2"S-1L-1WC-1SH-1 WB-1 1/2" 1/2" 1/2" 1/2" 3/4" 1/2"3/4" 3/4"3/4"1/2"1/2"1/2"1/2"1/2"1/2"1/2"S-1 WB-1 S-1 WB-1 RISER-3 S-1 L-1 WC-1 SH-11/2"1/2"1/2"1/2"1/2"1/2"3/4" 1/2"3/4" S-1 L-1 WC-1 SH-11/2"1/2"1/2"1/2"1/2"1/2"3/4" 1/2"3/4" S-1 L-1 WC-1 SH-11/2"1/2"1/2"1/2"1/2"1/2"3/4"3/4" 1/2" S-1 L-1 WC-1 SH-1 1/2" 1/2" 3/4" 1/2"1/2"1/2"1/2"1/2"RISER-4 S-1 L-1 WC-1 SH-11/2"1/2"1/2"1/2"1/2"1/2"3/4" 1/2"3/4" S-1 L-1 WC-1 SH-11/2"1/2"1/2"1/2"1/2"1/2"3/4" 1/2"3/4" S-1 L-1 WC-1 SH-21/2"1/2"1/2"1/2"1/2"1/2"3/4"3/4" 1/2" S-1 L-1 WC-1 SH-4 1/2" 1/2" 3/4" 1/2"1/2"1/2"1/2"1/2"RISER-5 S-1L-1WC-1SH-1 1/2"1/2"1/2"1/2"1/2"1/2"3/4" 1/2"3/4" S-1L-1WC-1SH-1 1/2"1/2"1/2"1/2"1/2"1/2"3/4" 1/2"3/4" S-1L-1WC-1SH-1 1/2"1/2"1/2"1/2"1/2"1/2"3/4"3/4" 1/2" S-1L-1WC-1SH-1 1/2" 1/2" 3/4" 1/2"1/2"1/2"1/2"1/2"RISER-6 S-1L-1WC-1SH-1 1/2"1/2"1/2"1/2"1/2"1/2"3/4" 1/2"3/4" S-1L-1WC-1SH-1 1/2"1/2"1/2"1/2"1/2"1/2"3/4" 1/2"3/4" S-1L-1WC-1SH-1 1/2"1/2"1/2"1/2"1/2"1/2"3/4" 1/2" S-1L-1WC-1SH-1 1/2" 1/2" 3/4" 1/2" 1-1/4"1/2"1/2"1/2"1/2"RISER-7 S-1L-1WC-1SH-1 1/2"1/2"1/2"1/2"1/2"1/2"3/4" 1/2"3/4" S-1L-1WC-1SH-1 1/2"1/2"1/2"1/2"1/2"1/2"3/4" 1/2" S-1L-1WC-1SH-1 1/2" 1/2" 3/4" 1/2" 1-1/4"1/2"1/2"1/2"1/2"RISER-8 S-1 L-1 WC-1 SH-11/2"1/2"1/2"1/2"1/2"1/2"1"2"3/4" 1/2"3/4" S-1 L-1 WC-1 SH-11/2"1/2"1/2"1/2"1/2"1/2"1"3/4" 1/2"3/4" S-1 L-1 WC-1 SH-11/2"1/2"1/2"1/2"1/2"1/2"3/4"3/4" 1/2" S-1 L-1 WC-1 SH-1 1/2" 1/2" 3/4" 1/2"1/2"1/2"1/2"1/2"RISER-9 S-1L-1WC-1SH-1 1/2"1/2"1/2"1/2"1/2"1/2"3/4" 1/2"3/4" S-1L-1WC-1SH-1 1/2"1/2"1/2"1/2"1/2"1/2"1"3/4" 1/2"3/4" S-1L-1WC-1SH-1 1/2"1/2"1/2"1/2"1/2"1/2"3/4"3/4" 1/2" S-1L-1WC-1SH-4 1/2" 1/2" 3/4" 1/2"1/2"1/2"1/2"1/2"RISER-10 S-1 L-1 WC-1 SH-11/2"1/2"1/2"1/2"1/2"1"2"3/4" 1/2"3/4" S-1 L-1 WC-1 SH-11/2"1/2"1/2"1/2"1/2"1"1-1/2"3/4" 1/2"3/4" S-1 L-1 WC-1 SH-11/2"1/2"1/2"1/2"1/2"3/4"3/4" 1/2" S-1 L-1 WC-1 SH-1 1/2" 1/2" 3/4" 1/2"1/2"1/2"1/2"1/2"RISER-11 S-1 L-1 WC-1 SH-11/2"1/2"1/2"1/2"1/2"1"2"3/4" 1/2"3/4" S-1 L-1 WC-1 SH-11/2"1/2"1/2"1/2"1/2"1"1-1/2"3/4" 1/2"3/4" S-1 L-1 WC-1 SH-11/2"1/2"1/2"1/2"1/2"3/4"3/4" 1/2" S-1 L-1 WC-1 SH-1 1/2" 1/2" 3/4" 1/2"1/2"1/2"1/2"1/2"3/4 HWC"3/4 HWC"3/4 HWC"3/4 HWC"1/2"3/4"3/4"1/2"3/4"3/4"1/2"3/4"3/4"1/2"3/4"3/4"1-1/4"1-1/4"1/2"3/4"3/4"1"3/4"3/4"3/4 HWC"3/4 HWC"1/2"3/4"3/4"1/2"3/4"3/4"1"1"1/2"1-1/4"1-1/4"1-1/4"1-1/4"1"1"1"1"1/2"3/4"3/4"3/4"1/2"3/4"3/4"1"1"3/4"3/4"1/2"3/4"3/4"1/2"3/4 HWC"3/4 HWC"1/2"3/4"3/4"1/2"3/4"3/4"1/2"3/4"3/4"1/2"3/4"3/4"1-1/4"1-1/4"1-1/4"1-1/4"1"1"1"1/2"3/4"3/4"3/4"1/2"3/4"3/4"1"1"3/4"3/4"1/2"3/4"3/4"1/2"3/4 HWC"3/4 HWC"1/2"3/4"3/4"1/2"3/4"3/4"1/2"3/4"3/4"1/2"3/4"3/4"3/4 HWC"3/4 HWC"3/4 HWC"3/4 HWC"1-1/4"1-1/4"1"1"1/2"3/4"3/4"1"3/4"3/4"1/2"3/4 HWC"3/4 HWC"1/2"3/4"3/4"1/2"3/4"3/4"1-1/4"1-1/4"1"1"1/2"3/4"3/4"1"3/4"3/4"1/2"3/4 HWC"3/4 HWC"1/2"3/4"3/4"1/2"3/4"3/4"1-1/4"1-1/4"1/2"3/4"3/4" 3/4"3/4"1/2"3/4 HWC"3/4 HWC"1/2"3/4"3/4"1/2"3/4"3/4"1-1/4"1-1/4"1/2"3/4"3/4" 3/4"3/4"1/2"3/4 HWC"3/4 HWC"1/2"3/4"3/4"1"1"MANUAL CIRCUIT SETTER, TYP. SET TO 0.75 GPM 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" ROOF 5th FLOOR 4th FLOOR 3rd FLOOR 2nd FLOOR GROUND FLOOR UNDERFLOOR S-1 L-1 WC-1 SH-11/2"1/2"1/2"1/2"1/2"1/2"1/2"1-1/4"1-1/4"3/4" 1/2"3/4" S-1 L-1 WC-1 SH-11/2"1/2"1/2"1/2"1/2"1/2"1/2"1"1"3/4" 1/2"3/4" S-1 L-1 WC-1 SH-11/2"1/2"1/2"1/2"1/2"1/2"1/2"3/4"3/4" 1/2" 3/4" 3/4" 3/4" S-1 L-1 WC-1 SH-1 1"1/2" 1/2" 3/4" 1/2"3/4" 3/4"3/41/2"1/2"1/2"1/2"1/2"S-1L-1WC-1SH-1 1/2"1/2"1/2"1/2"1/2"1/2"1/2"1-1/4"1-1/4"3/4" 1/2"3/4" S-1L-1WC-1SH-1 1/2"1/2"1/2"1/2"1/2"1/2"1/2"1"1"3/4" 1/2"3/4" S-1L-1WC-1SH-1 1/2"1/2"1/2"1/2"1/2"1/2"1/2"3/4"3/4" 1/2" 3/4"3/4" S-1L-1WC-1SH-1 1"1/2" 1/2" 3/4" 1/2" 3/4"3/4"1/2"1/2"1/2"1/2"1/2"S-1L-1WC-1SH-1 1/2"1/2"1/2"1/2"1/2"1/2"3/4" 1/2"3/4" S-1L-1WC-1SH-1 1/2"1/2"1/2"1/2"1/2"1/2"3/4" 1/2"3/4" S-1L-1WC-1SH-1 1/2"1/2"1/2"1/2"1/2"1/2"3/4" 1/2" S-1L-1WC-1SH-1 1/2" 1/2" 3/4" 1/2"1/2"1/2"1/2"1/2"S-1 L-1 WC-1 SH-31/2"1/2"1/2"1/2"1/2"1/2"3/4" 1/2"3/4" S-1 L-1 WC-1 SH-31/2"1/2"1/2"1/2"1/2"1/2"3/4" 1/2"3/4" S-1 L-1 WC-1 SH-31/2"1/2"1/2"1/2"1/2"1/2"3/4" 1/2" S-1 L-1 WC-1 SH-3 1/2" 1/2" 3/4" 1/2"1/2"1/2"1/2"1/2"S-1L-1WC-1SH-3 1/2"1/2"1/2"1/2"1/2"1/2"3/4" 1/2"3/4" S-1L-1WC-1SH-3 1/2"1/2"1/2"1/2"1/2"1/2"3/4" 1/2"3/4" S-1L-1WC-1SH-3 1/2"1/2"1/2"1/2"1/2"1/2"3/4" 1/2" S-1L-1WC-1SH-3 1/2" 1/2" 3/4" 1/2"1/2"1/2"1/2"1/2"S-1 L-1 WC-1 SH-11/2"1/2"1/2"1/2"1/2"1/2"3/4" 1/2"3/4" S-1 L-1 WC-1 SH-11/2"1/2"1/2"1/2"1/2"1/2"3/4" 1/2"3/4" S-1 L-1 WC-1 SH-11/2"1/2"1/2"1/2"1/2"1/2"3/4" 1/2" S-1 L-1 WC-1 SH-1 1/2" 1/2" 3/4" 1/2"1/2"1/2"1/2"1/2"S-1L-1WC-1SH-1 1/2"1/2"1/2"1/2"1/2"1/2"3/4" 1/2"3/4" S-1L-1WC-1SH-1 1/2"1/2"1/2"1/2"1/2"1/2"3/4" 1/2"3/4" S-1L-1WC-1SH-1 1/2"1/2"1/2"1/2"1/2"1/2"3/4" 1/2" S-1L-1WC-1SH-1 1/2" 1/2" 3/4" 1/2"1/2"1/2"1/2"1/2"S-1 L-1 WC-1 SH-11/2"1/2"1/2"1/2"1/2"1/2"3/4" 1/2"3/4" S-1 L-1 WC-1 SH-11/2"1/2"1/2"1/2"1/2"1/2"3/4" 1/2" 1-1/4" 3/4" 1-1/4" S-1 L-1 WC-1 SH-11/2"1/2"1/2"1/2"1/2"1/2"3/4" 1/2" S-1 L-1 WC-1 SH-1 1/2" 1/2" 3/4" 1/2"1/2"1/2"1/2"1/2"S-1L-1WC-1SH-1 1/2"1/2"1/2"1/2"1/2"1/2"3/4" 1/2"3/4" S-1L-1WC-1SH-1 1/2"1/2"1/2"1/2"1/2"1/2"3/4" 1/2"3/4" S-1L-1WC-1SH-1 1/2"1/2"1/2"1/2"1/2"1/2"3/4" 1/2" S-1L-1WC-1SH-1 1/2" 1/2" 3/4" 1/2"1/2"1/2"1/2"1/2"S-1 L-1 WC-1 SH-11/2"1/2"1/2"1/2"1/2"1/2"3/4" 1/2"3/4" S-1 L-1 WC-1 SH-11/2"1/2"1/2"1/2"1/2"1/2"3/4" 1/2"3/4" S-1 L-1 WC-1 SH-11/2"1/2"1/2"1/2"1-1/4"1/2"1/2"3/4" 1/2" S-1 L-1 WC-1 SH-1 1/2" 1/2" 3/4" 1/2"1/2"1/2"1/2"1/2"S-1L-1WC-1SH-1 1/2"1/2"1/2"1/2"1-1/4"1/2"1/2"3/4" 1/2"3/4" S-1L-1WC-1SH-1 1/2"1/2"1/2"1/2"1/2"1/2"3/4" 1/2"3/4" S-1L-1WC-1SH-1 1/2"1/2"1/2"1/2"1-1/4"1/2"1/2"3/4" 1/2" S-1L-1WC-1SH-1 1/2" 1/2" 3/4" 1/2"1/2"1/2"1/2"1/2"1-1/4"RISER-12 RISER-13 RISER-15 RISER-16RISER-14 RISER-17 RISER-18 RISER-19 RISER-20 RISER-21 RISER-22 3/4"3/4"3/4"3/4" 3/4"3/4"3/4"3/4"3/4" HWC3/4" HWC3/4" HWC3/4" HWC1/2"1-1/4"1-1/4"1/2"1"1"1/2"3/4"3/4"3/4"1"3/4"3/41/2"3/4"3/4" 3/4"3/4"3/4" HWC3/4" HWC1/2"1-1/4"1-1/4"1/2"1"1"1/2"3/4"3/4"3/4"1"3/4"3/41/2"3/4"3/4" 3/4"3/4"3/4" HWC3/4" HWC1/2"1-1/4"1-1/4"1/2"1"1"1/2"3/4"3/4"3/4"1"3/4"3/41/2"3/4"3/4" 3/4"3/4"3/4" HWC3/4" HWC1/2"1-1/4"1-1/4"1/2"1"1"1/2"3/4"3/4"3/4"1"3/4"3/41/2"3/4"3/4" 3/4"3/4"3/4" HWC3/4" HWC1/2"1-1/4"1-1/4"1/2"1"1"1/2"3/4"3/4"3/4"1"3/4"3/4"1/2"3/4"3/4" 3/4"3/4"3/4" HWC3/4" HWC1/2"1-1/4"1-1/4"1/2"1"1"1/2"3/4"3/4"3/4"1"3/4"3/4"1/2"3/4"3/4" 3/4"3/4"3/4" HWC3/4" HWC1/2"1-1/4"1-1/4"1/2"1"1"1/2"3/4"3/4"3/4"1"3/4"3/4"1/2"3/4"3/4" 3/4"3/4"3/4" HWC3/4" HWC1/2"1-1/4"1-1/4"1/2"1"1"1/2"3/4"3/4"3/4"1"3/4"3/4"1/2"3/4"3/4" 3/4"3/4"3/4" HWC3/4" HWC1/2"1-1/4"1-1/4"1/2"1"1"1/2"3/4"3/4"3/4"1"3/4"3/4"1/2"3/4"3/4" 3/4"3/4"3/4" HWC3/4" HWC3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" www.coffman.com 221 N. Wall Street, Suite 500 Spokane, WA 99201 ph 509.328.2994 32 MERCHANT STREET, SUITE 208 HONOLULU, HI 96813 808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 99216DOMESTIC WATER RISER DIAGRAM P-603 FSC PROJECT NO. 21012 PERMIT SET MAY 30, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce Lane Spokane, WA 99206 (509) 919-0901 NTS1DOMESTIC WATER RISER 1 NTS2DOMESTIC WATER RISER 2 3/4" HWC, TYP.MANUAL CIRCUIT SETTER, TYP. SET TO 0.75 GPM Revision Schedule Number Description Date 5/30/2024 ROOF 5th FLOOR 4th FLOOR 3rd FLOOR 2nd FLOOR GROUND FLOOR UNDERFLOOR S-1L-1WC-1SH-1 1/2"1/2"1/2"1/2"1/2"1/2"3/4" 1/2"3/4" S-1L-1WC-1SH-1 1/2"1/2"1/2"1/2"1/2"1/2"3/4" 1/2"3/4" S-1L-1WC-1SH-1 1/2"1/2"1/2"1/2"1/2"1/2"3/4" 1/2"3/4" S-1L-1WC-1SH-1 1/2" 1/2" 3/4" 1/2"3/4"1/2"1/2"1/2"1/2"RISER-23 1/2"3/4" S-1L-1WC-1SH-1 1/2"1/2"1/2"1/2"1/2"1/2"3/4" S-1 L-1 WC-1 SH-11/2"1/2"1/2"1/2"1/2"1/2"3/4" 1/2"3/4" S-1 L-1 WC-1 SH-11/2"1/2"1/2"1/2"1/2"1/2"3/4" 1/2"3/4" S-1 L-1 WC-1 SH-11/2"1/2"1/2"1/2"1/2"1/2"3/4" 1/2" S-1 L-1 WC-1 SH-1 1/2" 1/2" 3/4" 1/2"1/2"1/2"1/2"1/2"S-1L-1WC-1SH-1 1/2"1/2"1/2"1/2"1/2"1/2"3/4" 1/2"3/4" S-1L-1WC-1SH-1 1/2"1/2"1/2"1/2"1/2"1/2"3/4" 1/2"3/4" S-1L-1WC-1SH-1 1/2"1/2"1/2"1/2"1/2"1/2"3/4" 1/2" S-1L-1WC-1SH-1 1/2" 1/2" 3/4" 1/2"1/2"1/2"1/2"1/2"RISER-24 RISER-25 S-1 L-1 WC-1 SH-11/2"1/2"1/2"1/2"1/2"1/2"3/4" 1/2"3/4" S-1L-1WC-1SH-1 1/2"1/2"1/2"1/2"1/2"1/2"3/4" 1/2"3/4" S-1 L-1 WC-1 SH-11/2"1/2"1/2"1/2"1/2"1/2"3/4" 1/2"3/4" S-1 L-1 WC-1 SH-11/2"1/2"1/2"1/2"1/2"1/2"3/4" 1/2"3/4" S-1 L-1 WC-1 SH-11/2"1/2"1/2"1/2"1/2"1/2"3/4" 1/2" S-1 L-1 WC-1 SH-1 1/2" 1/2" 3/4" 1/2"1/2"1/2"1/2"1/2"S-1L-1WC-1SH-3 1/2"1/2"1/2"1/2"1/2"1/2"3/4" 1/2"3/4" S-1L-1WC-1SH-3 1/2"1/2"1/2"1/2"1/2"1/2"3/4" 1/2"3/4" S-1L-1WC-1SH-3 1/2"1/2"1/2"1/2"1/2"1/2"3/4" 1/2" S-1L-1WC-1SH-3 1/2" 1/2" 3/4" 1/2"1/2"1/2"1/2"1/2"RISER-26 RISER-27 S-1 L-1 WC-1 SH-11/2"1/2"1/2"1/2"1/2"1/2"3/4" 1/2"3/4" S-1L-1WC-1SH-3 1/2"1/2"1/2"1/2"1/2"1/2"3/4" 1/2"3/4" S-1 L-1 WC-1 SH-11/2"1/2"1/2"1/2"1/2"1/2"3/4" 1/2"3/4" S-1 L-1 WC-1 SH-11/2"1/2"1/2"1/2"1/2"1/2"3/4" 1/2"3/4" S-1 L-1 WC-1 SH-11/2"1/2"1/2"1/2"1/2"1/2"3/4" 1/2" S-1 L-1 WC-1 SH-1 1/2" 1/2" 3/4" 1/2"1/2"1/2"1/2"1/2"S-1L-1WC-1SH-1 1/2"1/2"1/2"1/2"1/2"1/2"3/4" 1/2"3/4" S-1L-1WC-1SH-1 1/2"1/2"1/2"1/2"1/2"1/2"3/4" 1/2"3/4" S-1L-1WC-1SH-1 1/2"1/2"1/2"1/2"1/2"1/2"3/4" 1/2" S-1L-1WC-1SH-1 1/2" 1/2" 3/4" 1/2"1/2"1/2"1/2"1/2"RISER-28 RISER-29 S-1 L-1 WC-1 SH-11/2"1/2"1/2"1/2"1/2"1/2"3/4" 1/2"3/4" S-1L-1WC-1SH-1 1/2"1/2"1/2"1/2"1/2"1/2"3/4" 1/2"3/4" S-1 L-1 WC-1 SH-41/2"1/2"1/2"1/2"1/2"1/2"3/4" 1/2"3/4" S-1 L-1 WC-1 SH-41/2"1/2"1/2"1/2"1/2"1/2"3/4" 1/2"3/4" S-1 L-1 WC-1 SH-11/2"1/2"1/2"1/2"1/2"1/2"3/4" 1/2" S-1 L-1 WC-1 SH-1 1/2" 1/2" 3/4" 1/2"1/2"1/2"1/2"1/2"S-1L-1WC-1SH-1 1/2"1/2"1/2"1/2"1/2"1/2"3/4" 1/2"3/4" S-1L-1WC-1SH-1 1/2"1/2"1/2"1/2"1/2"1/2"3/4" 1/2"3/4" S-1L-1WC-1SH-1 1/2"1/2"1/2"1/2"1/2"1/2"3/4" 1/2" S-1L-1WC-1SH-1 1/2" 1/2" 3/4" 1/2" 1-1/4"1/2"1/2"1/2"RISER-30 RISER-31 S-1 L-1 WC-1 SH-41/2"1/2"1/2"1/2"1/2"1/2"3/4" 1/2"3/4" S-1L-1WC-1SH-1 1/2"1/2"1/2"1/2"1/2"1/2"3/4" 1/2"3/4"1-1/4"1-1/4"1/2"3/4"3/4" 3/4"3/4"1/2"3/4 HWC"3/4 HWC"1/2"3/4"1/2"3/4"1-1/4"1-1/4"1/2"3/4"3/4" 3/4"3/4"1/2"3/4 HWC"3/4 HWC"1/2"3/4"1/2"3/4"1"3/4"1"1"1-1/4"1-1/4"3/4"3/4" 3/4" 3/4" 3/4" 3/4"1-1/4"1-1/4"1/2"3/4"3/4" 3/4"1/2"3/4 HWC"3/4 HWC"1/2"3/4"1/2"3/4"1"3/4"1"1"1-1/4"1-1/4"3/4"3/4" 3/4" 3/4" 3/4" 3/4"1-1/4"1-1/4"1/2"3/4"3/4" 3/4"1/2"3/4 HWC"3/4 HWC"1/2"3/4"1/2"3/4"1"3/4"1"1"1-1/4"1-1/4"3/4"3/4" 3/4" 3/4" 3/4" 3/4"1-1/4"1-1/4"1/2"3/4"3/4" 3/4"1/2"3/4 HWC"3/4 HWC"1/2"3/4"1/2"3/4"1"3/4"1"1"1-1/4"1-1/4"3/4"3/4" 3/4" 3/4" 3/4" 3/4"1-1/4"1-1/4"1/2"3/4"3/4" 3/4"1/2"3/4 HWC"3/4 HWC"1/2"3/4"1/2"3/4"1"3/4"1"1"1-1/4"1-1/4"3/4"3/4" 3/4" 3/4"3/4"3/4"3/4"3/4"3/4" 3/4" 3/4"1/2"1/2"1/2"1/2"1/2"1-1/4"1-1/4"1/2"3/4"3/4" 3/4"3/4"1/2"3/4 HWC"3/4 HWC"1/2"3/4"1/2"3/4" 3/4" 3/4"1-1/4"1-1/4"1/2"3/4"3/4" 3/4"3/4"1/2"3/4 HWC"3/4 HWC"1/2"3/4"1/2"3/4" 3/4" 3/4"1-1/4"1-1/4"1/2"3/4"3/4" 3/4"3/4"1/2"3/4 HWC"3/4 HWC"1/2"3/4"1/2"3/4" 3/4" 3/4"1/2"1/2"1/2"1/2"3/4"3/4"3/4"3/4" 3/4"3/4"3/4"3/4" 3/4"3/4"3/4"3/4"3/4"3/4"3/4"3/4"1-1/4"1-1/4"3/4"3/4"1-1/4"1-1/4"1-1/4"1-1/4"3/4"1-1/4"1-1/4"3/4"MANUAL CIRCUIT SETTER, TYP. SET TO 0.75 GPM 3/4" HWC, TYP. www.coffman.com 221 N. Wall Street, Suite 500 Spokane, WA 99201 ph 509.328.2994 32 MERCHANT STREET, SUITE 208 HONOLULU, HI 96813 808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 99216DOMESTIC WATER RISER DIAGRAM P-604 FSC PROJECT NO. 21012 PERMIT SET MAY 30, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce Lane Spokane, WA 99206 (509) 919-0901 NTS1DOMESTIC WATER RISER 3 Revision Schedule Number Description Date 5/30/2024 5th FLOOR 4th FLOOR 3rd FLOOR 2nd FLOOR GROUND FLOOR UNDERFLOOR STACK-1 STACK-2 STACK-3 STACK-6STACK-4 STACK-5 STACK-7 STACK-8 STACK-9 STACK-10 STACK-11 PTAC-1 BALCONY3/4" D 3/4" D PTAC-1 BALCONY3/4" D 3/4" D PTAC-1 BALCONY3/4" D 3/4" D PTAC-1 BALCONY3/4" D 3/4" D PTAC-1 3/4" D PTAC-1 3/4" D PTAC-1 3/4" D PTAC-1 3/4" D PTAC-1 3/4" D PTAC-1 3/4" D PTAC-1 3/4" D PTAC-1 3/4" D PTAC-1 3/4" D PTAC-1 3/4" D PTAC-1 3/4" D PTAC-1 3/4" D PTAC-1 3/4" D PTAC-1 3/4" D PTAC-1 3/4" D PTAC-1 BALCONY 3/4" D 3/4" D PTAC-1 BALCONY 3/4" D 3/4" D PTAC-1 BALCONY 3/4" D 3/4" D PTAC-1 BALCONY 3/4" D 3/4" D PTAC-1 BALCONY3/4" D 3/4" D PTAC-1 BALCONY3/4" D 3/4" D PTAC-1 BALCONY3/4" D 3/4" D PTAC-1 BALCONY3/4" D 3/4" D PTAC-1 BALCONY 3/4" D 3/4" D PTAC-1 BALCONY 3/4" D 3/4" D PTAC-1 BALCONY 3/4" D 3/4" D PTAC-1 BALCONY 3/4" D 3/4" D PTAC-1 BALCONY3/4" D 3/4" D PTAC-1 BALCONY3/4" D 3/4" D PTAC-1 BALCONY3/4" D 3/4" D PTAC-1 BALCONY3/4" D 3/4" D PTAC-1 3/4" D PTAC-1 3/4" D PTAC-1 3/4" D PTAC-1 3/4" D PTAC-1 3/4" D PTAC-1 3/4" D PTAC-1 3/4" D PTAC-1 3/4" D PTAC-1 3/4" D STACK-12 STACK-13 PTAC-1 3/4" D PTAC-1 3/4" D PTAC-1 3/4" D PTAC-1 3/4" D PTAC-1 3/4" D PTAC-1 3/4" D PTAC-1 3/4" D PTAC-1 3/4" D PTAC-1 3/4" D PTAC-1 3/4" D STACK-14 STACK-15 PTAC-1 BALCONY 3/4" D 3/4" D PTAC-1 BALCONY 3/4" D 3/4" D PTAC-1 BALCONY 3/4" D 3/4" D PTAC-1 BALCONY 3/4" D 3/4" D PTAC-1 BALCONY 3/4" D 3/4" D PTAC-1 BALCONY 3/4" D 3/4" D PTAC-1 BALCONY 3/4" D 3/4" D PTAC-1 BALCONY 3/4" D 3/4" D PTAC-1 BALCONY 3/4" D 3/4" D PTAC-1 BALCONY 3/4" D 3/4" D STACK-16 PTAC-1 3/4" D PTAC-1 3/4" D PTAC-1 3/4" D PTAC-1 3/4" D PTAC-1 3/4" D STACK-17 PTAC-1 3/4" D PTAC-1 3/4" D PTAC-1 3/4" D PTAC-1 3/4" D PTAC-1 3/4" D 5th FLOOR 4th FLOOR 3rd FLOOR 2nd FLOOR GROUND FLOOR UNDERFLOOR STACK-33 PTAC-1 BALCONY 3/4" D 3/4" D PTAC-1 BALCONY 3/4" D 3/4" D PTAC-1 BALCONY 3/4" D 3/4" D PTAC-1 BALCONY 3/4" D 3/4" D STACK-18 PTAC-1 3/4" D PTAC-1 3/4" D PTAC-1 3/4" D PTAC-1 3/4" D PTAC-1 3/4" D STACK-20 PTAC-1 3/4" D PTAC-1 3/4" D PTAC-1 3/4" D PTAC-1 3/4" D STACK-19 PTAC-1 3/4" D PTAC-1 3/4" D PTAC-1 3/4" D PTAC-1 3/4" D PTAC-1 3/4" D STACK-21 PTAC-1 3/4" D PTAC-1 3/4" D PTAC-1 3/4" D PTAC-1 3/4" D STACK-22 PTAC-1 3/4" D PTAC-1 3/4" D PTAC-1 3/4" D PTAC-1 3/4" D STACK-23 PTAC-1 3/4" D PTAC-1 3/4" D PTAC-1 3/4" D PTAC-1 3/4" D STACK-24 PTAC-1 3/4" D PTAC-1 3/4" D PTAC-1 3/4" D PTAC-1 3/4" D STACK-25 PTAC-1 3/4" D PTAC-1 3/4" D PTAC-1 3/4" D PTAC-1 3/4" D STACK-26 PTAC-1 3/4" D PTAC-1 3/4" D PTAC-1 3/4" D PTAC-1 3/4" D STACK-27 PTAC-1 3/4" D PTAC-1 3/4" D PTAC-1 3/4" D PTAC-1 3/4" D STACK-28 PTAC-1 3/4" D PTAC-1 3/4" D PTAC-1 3/4" D PTAC-1 3/4" D STACK-29 PTAC-1 3/4" D PTAC-1 3/4" D PTAC-1 3/4" D PTAC-1 3/4" D STACK-30 PTAC-1 3/4" D PTAC-1 3/4" D PTAC-1 3/4" D PTAC-1 3/4" D STACK-31 PTAC-1 3/4" D PTAC-1 3/4" D PTAC-1 3/4" D PTAC-1 3/4" D STACK-32 PTAC-1 3/4" D PTAC-1 3/4" D PTAC-1 3/4" D PTAC-1 3/4" D 1", TYP. ALL VERTICAL STACKS GENERAL NOTES A. TERMINATE DRAIN STACKS AT EXTERIOR WALL WITH DOWNWARD FACING ELBOW LOCATED 18" AFF. ALL EXPOSED EXTERIOR PIPING AND FITTINGS SHALL BE STEEL PAINTED TO MATCH EXTERIOR. PROVIDE ESCUTCHEON TO TRIM PIPING AT FINISHED EXTERIOR. B. ALL VERTICAL STACKS TO BE 1" PIPE. www.coffman.com 221 N. Wall Street, Suite 500 Spokane, WA 99201 ph 509.328.2994 32 MERCHANT STREET, SUITE 208 HONOLULU, HI 96813 808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 99216CONDENSATE DRAIN RISER DIAGRAM P-605 FSC PROJECT NO. 21012 PERMIT SET MAY 30, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce Lane Spokane, WA 99206 (509) 919-0901 NTS1CONDENSATE DRAIN RISER DIAGRAM 1 NTS2CONDENSATE DRAIN RISER DIAGRAM 2 Revision Schedule Number Description Date 5/30/2024 PLUMBING FIXTURE SCHEDULE CATALOG NUMBER BRANCH CONNECTIONS TAG TYPE MFR FIXTURE TRIM SUPPLIES TRAP WASTE VENT CW HW NOTES FD-1 FLOOR DRAIN SMITH 2005Y02-A05CP TRAP PRIMER -P-TRAP 2" 1-1/2" 1/2" - 10, 11 FS-1 FLOOR SINK CECO 906-2 TRAP PRIMER -P-TRAP 2" 1-1/2" 1/2" - 10, 12 FS-2 FLOOR SINK CECO 906-4 TRAP PRIMER -P-TRAP 4" 2" 1/2" - 10, 12 HB-1 HOSE BIBB, EXTERIOR WOODFORD 67-CH TEE KEY -- - - 3/4" -9 HB-2 HOSE BIBB, INTERIOR WOODFORD 24-CH TEE KEY -- - - 3/4" -15 BF-1 BOTTLE FILLER ELKAY LZWSM8K WALL BRACKET -P-TRAP 2" 1-1/2" 1/2" -3 WC-1 WATER CLOSET, FLUSH TANK, ADA KOHLER K-3999 KOHLER K-20110 SEAT, WITH COVER -- 4" 2" 1/2" -1 WC-2 WATER CLOSET, FLUSHOMETER, ADA KOHLER K-84325 OPEN FRONT SEAT, LESS COVER K-10TH00N10 - 4" 2" 1" -1, 2 U-1 URINAL KOHLER K-4991 -K-10UD00K20-CP - 2" 2" 3/4" - 1, 2, 3 L-1 LAV, COUNTERTOP STERLING 442007-U MOEN 6191 GRID DRAIN P-TRAP 2" 1-1/2" 1/2" 1/2"4 L-2 LAV, WALL MOUNT KOHLER K-2035-1 MOEN 6192 GRID DRAIN P-TRAP 2" 1-1/2" 1/2" 1/2"4 S-1 SINK, KITCHENETTE STERLING 11447 MOEN 7565 BASKET STRAINER P-TRAP 2" 1-1/2" 1/2" 1/2"4 S-2 SINK, LAUNDRY MUSTEE 24C UTILATWIN CHICAGO FAUCET W4D-DB6AE1-317ABCP -P-TRAP 2" 1-1/2" 1/2" 1/2"4 MB-1 MOP BASIN ADVANCE TABCO 9-OPC-84 CHICAGO FAUCET 897-RFC -P-TRAP 3" 2" 1/2" 1/2"7 SH-1 SHOWER MINCEYMARBLE TD-366-0S/SF-L 60X36 SHOWER, LEFT DRAIN 2 IN 1 DELTA 58472, OATEY 42045 DRAIN P-TRAP 2" 1-1/2" 1/2" 1/2"8 SH-2 SHOWER, ADA COMFORT DESIGNS SSB6238TR.75-WHG 62X38 SHOWER, FRONT CENTER DRAIN SLIDING HAND SHOWER DELTA 51361 WITH DELTA 52488 SHOWER HEAD, SEAT, INTEGRAL FRONT TRENCH DRAIN P-TRAP 2" 1-1/2" 1/2" 1/2" 5, 8, 16 SH-3 BATH/SHOWER KOHLER K-25831-LA 60X36 BATHTUB, LEFT DRAIN 2 IN 1 DELTA 58472, MOEN T2193 TUB FILL, GRID DRAIN P-TRAP 2" 1-1/2" 1/2" 1/2" 6, 8, 17 SH-4 BATH/SHOWER, ADA KOHLER K-25831-LA 60X36 BATHTUB, LEFT DRAIN SLIDING HAND SHOWER DELTA 51361, DELTA 52488 SHOWER HEAD, MOEN T2193 TUB FILL, GRID DRAIN P-TRAP 2" 1-1/2" 1/2" 1/2" 6, 8, 18 SH-5 SHOWER, ADA COMFORT DESIGNS SWB3838TR.75C.010 37X38 SHOWER, CENTER DRAIN SLIDING HAND SHOWER DELTA 51361 WITH DELTA 52488 SHOWER HEAD, GRID DRAIN P-TRAP 2" 1-1/2" 1/2" 1/2"8 WB-1 WATER BOX - CLOTHES WASHER GUY GRAY MWB-10 --P-TRAP 2" 1-1/2" 3/4" 3/4"1 WB-2 WATER BOX - WATER ONLY GUY GRAY MIB1 --- - - 1/2" -1 EW-1 EMERGENCY EYE WASH HAWS 7610 EMERGENCY SIGNAGE -- - - - 1/2"- TD-1 TRENCH DRAIN, POOL DECK STEGMEIER -2" PVC DECK DRAIN -- 2" - - -- TD-2 TRENCH DRAIN, LAUNDRY H-M COMPANY HM-430 -LINT FILTER P-TRAP 6" - - -14 RD-1 ROOF DRAIN SMITH 1015Y03-R-C-CID UNDERDECK CLAMP, SUMP RECEIVER CAST IRON DOME - 2" - - -- OD-1 OVERFLOW DRAIN SMITH 1045Y03-R-C-CID UNDERDECK CLAMP, SUMP RECEIVER CAST IRON DOME - 2" - - -- DS-1 DOWNSPOUT NOZZLE SMITH 1770-BS --- - - - -13 1. PROVIDE & INSTALL WATER HAMMER ARRESTOR ON CW LINE SERVING FIXTURE, SEE PLAN FOR SIZE. 2. PROVIDE AND INSTALL SUPPORT CARRIER. 3. SEE ARCHITECTURAL FOR MOUNTING HEIGHT. 4. OFFSET EXPOSED TRAPS FOR ADA COMPLIANCE. INSULATE ALL EXPOSED PIPING (CW, HW, & SAN) BELOW SINK WITH TRUEBRO MODEL 102 & 105 HANDI LAV-GUARD KIT. 5. CONTRACTOR TO VERIFY REQUIRED SEAT ORIENTATION. 6. CONTRACTOR TO VERIFY REQUIRED DRAIN ORIENTATION. 7. PROVIDE AND INSTALL MOP HANGER, HOSE AND WALL BRACKET. 8. COORDINATE WITH ARCHITECT FOR GRAB BAR LOCATIONS. 9. KEY OPERATED QUARTER TURN, FREEZELESS, WITH BACKFLOW PREVENTER. VERIFY WALL THICKNESS WITH ARCHITECTURAL. 10. PROVIDE PRECISION PLUMBING PRODUCTS, INC. MODEL P1/P2 TRAP PRIMER. ROUTE 1/2" PIPING TO FLOOR DRAIN/SINK. 11. USE SQUARE STRAINER IN TILE FLOOR AND ROUND STRAINER IN CONCRETE FLOORS. 12. 12" SQUARE, 8" DEEP, COATED CAST IRON, ALUMINUM DOME BOTTOM STRAINER, WITH TRAP PRIMER CONNECTION. 13. SEE PLAN FOR SIZE; NOZZLE SHALL MATCH OVERFLOW RAIN LEADER SIZE. 14. PROVIDE A MINIMUM 1" GAP BETWEEN TROUGH AND DRAIN PIPE. 15. KEY OPERATED QUARTER TURN, WITH BACKFLOW PREVENTER. VERIFY WALL THICKNESS WITH ARCHITECTURAL. 16. ADA ROLL-IN SHOWER, CONTROLS ON BACK WALL, SEE ARCH FOR DETAILS. UNITS 338, 403. 17. SHOWER/TUB COMBO. SEE ARCH FOR DETAILS. UNITS 136, 222, 224, 236, 322, 324, 336, 422, 424, 436, 522, 524, 536. 18. ADA SHOWER, CONTROLS ON SHAFT WALL, OVERHEAD AND HANDHELD SHOWER HEAD W/ DIVERTER ON SHAFT WALL, SEE ARCH FOR DETAILS. UNITS 138, 238, 303, 503, 512 KITCHEN EQUIPMENT, PLUMBING CONNECTIONS EQUIPMENT PLUMBING CONNECTIONS QTY DESCRIPTION DIRECT WASTE VENT INDIRECT WASTE CW 140F HW 120F HW NG NOTES 2 HAND SINK 2"2"-1/2" - 1/2" -1,2 1 THREE COMPARTMENT SINK --2"1/2" 1/2" - -1,2 2 DISHWASHER, UNDERCOUNTER --3/4"- 3/4" - -1,2 1 PREP SINK --2"1/2" 1/2" - -1,2 1 MOP SINK 2"2"-1/2" 1/2" - -1,2 1 NUGGET ICE MAKER --3/4"1/2" - - -1,2 1 SINK 2"2"-1/2" - 1/2" -1,2 1 FLOOR TROUGH 4"2"-- - - -1,2 1 MAKE UP AIR UNIT --1-1/2"1/2" - - 1/2"1,2 1 DRAFT BEER COOLER ---1/2" - - -1,2 1 DISPOSAL 2"2"-- - - -1,2 1 ICE BIN --1"- - - -1,2 1 OUTDOOR GRILL ---- - - 1/2"1,2 1. OWNER PROVIDED, CONTRACTOR INSTALLED. 2. REFER TO KITCHEN EQUIPMENT PLANS FOR EQUIPMENT LOCATION. DRAINAGE FIXTURE UNIT VALUES - PUBLIC FIXTURE DESCRIPTION QTY.FIXTURE UNITS TOTAL Drinking Fountain or Watercooler 2 0.5 1 Lavatory, single 139 1 139 Floor Drain, emergency 16 0 0 Floor Drain 1 2 2 Urinal, 1.0 GPF 2 2 4 Water Closet, 1.28 GPF flushometer valve 7 4 28 Water Closet, 1.28 GPF tank 132 4 528 Bathtub or Combination Bath/Shower 135 2 270 Clotheswasher, commercial, 3" standpipe 7 6 42 Sink, Laundry 1 2 2 Sink, Service or Mop Basin, 3" trap 5 3 15 Sink, Wash, each set of faucets 134 2 268 Sink, Kitchen, domestic with one 1-1/2" trap 2 2 4 Receptor, indirect waste, 2" trap, up to 7.5 gpm (1)2 1 2 Clotheswasher, domestic, 2" standpipe 8 3 24 Total Demand =1329 (1) FU DETERMINED BY TABLE 702.2(b). FIXTURE UNITS OBTAINED FROM TABLE 702.1, UNIFORM PLUMBING CODE, 2018 EDITION. WATER SUPPLY FIXTURE UNITS - PUBLIC FIXTURE DESCRIPTION QTY.FIXTURE UNITS (1)TOTAL Ice Maker 1 0.5 0.5 Drinking Fountain or Watercooler 2 0.5 1 Lavatory 139 1 139 Urinal, 1.0 GPF, flushometer valve 2 NOTE (2)20 Water Closet, 1.28 GPF Flushometer Valve 7 NOTE (2)135 Water Closet, 1.6 GPF Flushometer Tank 132 2.5 330 Clothes washer 18 4 72 Bathtub or Combination Bath/Shower 18 4 72 Shower, per head 116 2 232 Dishwasher, domestic 1 1.5 1.5 Sink, Kitchen, domestic 5 1.5 7.5 Sink, Laundry 1 1.5 1.5 Sink, Washup, each set of faucets 134 2 268 Sink, Service or Mop Basin 5 3 15 Hose Bibb (First one)1 2.5 2.5 Hose Bibb (Ea. additional)10 1 10 TOTAL DEMAND = 1307.5 (1) FIXTURE UNIT VALUES OBTAINED FROM TABLE 610.3. (2) FLUSHOMETER VALVE FIXTURE UNITS FOR WATER CLOSETS AND URINALS OBTAINED FROM TABLE 610.10. LENGTH FROM METER TO REMOTE FIXTURE = 500' PRESSURE RANGE (TABLE 6-5) =OVER 60 PSI WATER METER SIZE = 6" BUILDING SUPPLY SIZE = 6" FIXTURE UNITS OBTAINED FROM UNIFORM PLUMBING CODE, 2018 EDITION. WATER SOFTENERS SCHEDULE TAG LOCATION SERVES MANUFACTURER/ MODEL WATER FLOW PRESS. DROP TREATED WATER QUALITY (MAX)TANKS RESIN VOLUME RESIN CAPACITY ELECTRICAL REQUIOEMENTS UNIT POWER REQ'T WT. LBS.NOTES GPM TEMP °F PEAK PSI TURBIDITY (NTU) CHLORINE (MG/L) IRON (MG/L)CONSTRUCTION QT'Y SIZE H X DIA TOTAL CF GRAINS VOLT ø MCA WS-01 WATER HEATER ROOM DOMESTIC WATER CULLIGAN/200 40-120 15 120 1 15 1,2 1. WATER SOFTENER SHALL INCLUDE A TEN FOOT (MINIMUM) POWER CORD WITH WALL MOUNT TRANSFORMER. RECEPTACLE SHALL BE PROVIDED, MARK SWITCH OR OTHERWISE LOCATE TO AVOID ACCIDENTAL DEACTIVATION. 2. INSTALL DRAIN WITH AIR GAP AT LEAST TWO TIMES THE DIAMETER OF THE DRAIN PIPE TO PERMIT OBSERVATION OF THE DRAIN FLOW. NATURAL GAS CONNECTIONS EQUIPMENT INPUT (BTH/H)NUMBER OF UNITS CFH RUNOUT SIZE (IN) DUCT HEATER 400,000 1 400 3/4" WATER HEATER 499,900 4 2,000 1" ERV 550,000 1 550 1" FIRE PIT 120,000 3 360 1/2" BARBEQUE 74,500 1 75 1/2" GENERATOR 1,882,000 1 1,882 1-1/2" BOH DRYERS 150,000 3 450 1/2" POOL HEATERS 500,000 2 1000 1" MAU 123,000 1 123 1/2" FUTURE 500,000 1 500 - TOTAL 18 7,339 - www.coffman.com 221 N. Wall Street, Suite 500 Spokane, WA 99201 ph 509.328.2994 32 MERCHANT STREET, SUITE 208 HONOLULU, HI 96813 808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 99216PLUMBING SCHEDULES P-701 FSC PROJECT NO. 21012 PERMIT SET MAY 30, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce Lane Spokane, WA 99206 (509) 919-0901 Revision Schedule Number Description Date 5/30/2024 EXPANSION TANK SCHEDULE MFR / MODEL TANK ACCEPT. SYSTEM CHARGE SYSTEM VOLUME VOLUME VOLUME MIN. FILL MAX. SYS PRESS. PRESS. WEIGHT TAG SERVICE TYPE (GAL) (GAL) (GAL) TEMP (F) TEMP (F) (PSIG) (PSIG) (LBS)NOTES ET-1 DOMESTIC HOT WATER AMTROL / ST-120V-C DIA.68 35 950 48 170 12 125 850 (1) (1) SECURE TANK TO CONCRETE FLOOR, SEE STRUCTURAL. PLUMBING PUMP SCHEDULE MFR MODEL IMP.HEAD MOTOR MOTOR UNIT ELECTRICAL REQUIREMENTS TAG SERVICE NUMBER TYPE SIZE GPM FT H20 RPM SPEED VOLTS PHASE AMPS WATTS HP NOTES DHWP-1 DHWC TO BUILDING BELL & GOSSETT PL-130 IN-LINE - 23.5 20 3200 CONSTANT 115 1 4.8 - 2/5 1, 2, 4 DHWP-2 DHWC TO KITCHEN BELL & GOSSETT ECOCIRC 20-18 IN-LINE - 3 10 3664 CONSTANT 115 1 1 - - 1, 3, 4 SP-1 ELEVATOR LIBERTY PUMP ELV-280 SUMP - 50 13 3450 CONSTANT 115 1 8 - 1/2 5, 6 SP-2 ELEVATOR LIBERTY PUMP ELV-280 SUMP - 50 13 3450 CONSTANT 115 1 8 - 1/2 5, 6 1. PROVIDE WITH BELL & GOSSETT CHECK-TROL CTF SERIES FLANGES. 2. PROVIDE AQUASTAT TO TURN PUMP ON AT 105°F AND OFF AT 115°F (ADJ.), AND TIMER TO TURN ON/OFF PUMP DURING OCCUPIED AND UNOCCUPIED TIMES. 3. PROVIDE AQUASTAT TO TURN PUMP ON AT 130°F AND OFF AT 135°F (ADJ.), AND TIMER TO TURN ON/OFF PUMP DURING OCCUPIED AND UNOCCUPIED TIMES. 4. 3 SPEED CIRCULATOR. 5. ELEVATOR SUMP PUMP. PROVIDE WITH CONTROL PANEL WITH OILTECTOR CONTROL, REMOTE ALARM, FLOATS, CHECK VALVE. 6. DISCONNECT SWITCH BY E.C. GAS WATER HEATER SCHEDULE MFR / MODEL INPUT TANK RECOVERY THERMAL UNIT ELECTRICAL REQUIREMENTS WEIGHT TAG TYPE MBH CAPACITY GPH @ 100 F RISE EFFICIENCY VOLTS PHASE AMPS (LBS)LOCATION/SERVICE NOTES WH-1 AO SMITH / BTH-500 MXI DIRECT VENT, GAS 499.9 119 1152 95% 120 1 5 1850 WATER HEATER ROOM 1, 2, 3, 4 WH-2 AO SMITH / BTH-500 MXI DIRECT VENT, GAS 499.9 119 1152 95% 120 1 5 1850 WATER HEATER ROOM 1, 2, 3, 4 WH-3 AO SMITH / BTH-500 MXI DIRECT VENT, GAS 499.9 119 1152 95% 120 1 5 1850 WATER HEATER ROOM 1, 2, 3, 4 WH-4 AO SMITH / BTH-500 MXI DIRECT VENT, GAS 499.9 119 1152 95% 120 1 5 1850 WATER HEATER ROOM 1, 2, 3, 4 1. PROVIDE AND INSTALL TEMPERATURE & PRESSURE RELIEF VALVE; ROUTE TO FLOOR SINK. 2. FLUE EXHAUST SHALL BE POLYPROPYLENE OR AL29-4C SS. INTAKE PIPING MAY BE SCHED 40 PVC. 3. SET HEATER TO 165 F. 4. PROVIDE WITH CONDENSATE NEUTRALIZATION KIT, PIPE TO FLOOR SINK. www.coffman.com 221 N. Wall Street, Suite 500 Spokane, WA 99201 ph 509.328.2994 32 MERCHANT STREET, SUITE 208 HONOLULU, HI 96813 808-352-5299 NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK. OWNER: THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 99216PLUMBING SCHEDULES P-702 FSC PROJECT NO. 21012 PERMIT SET MAY 30, 2024 GL8 Mirabeau Point, LLC TMK:PID: 45101.040110909 E. Pierce Lane Spokane, WA 99206 (509) 919-0901 Revision Schedule Number Description Date 5/30/2024 TVGTVWAPHPT1T2T4TELECOMMUNICATIONS SCHEDULESYMBOLDESCRIPTIONNOTESCCTV OUTLET(1) RG6 CABLEPROVIDE COAXIAL CABLE WITH F-TYPECONNECTOR PLUG FROM DEVICE TO PBX ROOMAND TERMINATE ON PATCH PANEL.GUEST UNIT DOORBELLDOORBELL SHALL BE CAPABLE OF MANUALSHUTOFF VIA SWITCH INSIDE GUEST UNIT.GUEST UNIT DATA/CCTV COMBINATION OUTLET1-PORT ACTIVE, 1-PORT BLANK, (1) CAT 6 CABLE,(1) RG6 CABLE.PROVIDE CAT-6 CABLE FROM DEVICE TO PBXROOM AND TERMINATE ON PATCH PANEL.GUEST UNIT DATA/WAP COMBINATION OUTLET1-PORT ACTIVE, 1-PORT BLANK, (1) CAT 6 CABLEWALL MOUNTED WAP PROVIDED BY OTHERSPROVIDE CAT-6 CABLE FROM DEVICE TO PBXROOM AND TERMINATE ON PATCH PANEL.PUBLIC AREA HOUSE PHONE1-PORT ACTIVE, 1-PORT BLANK, (1) CAT 6 CABLESMOUNT AT +48"VOICE/DATA OUTLET, TOTAL OF 2-PORTS1-PORT ACTIVE, 1-PORT BLANK, (1) CAT 6 CABLESUBSCRIPT DENOTES NUMBER OF ACTIVEPORTSVOICE/DATA OUTLET, TOTAL OF 4-PORTS2-PORTS ACTIVE, 2-PORTS BLANK, (2) CAT 6CABLESSUBSCRIPT DENOTES NUMBER OF ACTIVEPORTSVOICE/DATA OUTLET, TOTAL OF 6-PORTS4-PORTS ACTIVE, 2-PORTS BLANK, (4) CAT 6CABLESSUBSCRIPT DENOTES NUMBER OF ACTIVEPORTSCADCESIICSIVRXSECURITY AND DOOR ACCESS SCHEDULESYMBOLDESCRIPTIONNOTESADA DOOR PUSHBUTTONPROVIDE ROUGH IN WITH CONNECTION TODOOR MOTOR. PROVIDE (1)1/2"C WITH CONTROLCABLING BETWEEN DOOR MOTOR ANDPUSHBUTTON. VERIFY LOCATIONS ANDCONNECTION REQUIREMENTS WITH EQUIPMENTPROVIDER. COORDINATE EQUIPMENTCONNECTIONS WITH ACCESS CONTROL SYSTEM.CARD ACCESS, PROXIMITY READER (ROUGH-INONLY)PROVIDE 4" SQUARE BACKBOX WITH 1"C ROUTEDTO NEAREST ACCESSIBLE CEILING SPACE.DOOR POSITION INDICATOR SWITCH (DPIS). PROVIDED WITH DOOR HARDWARE. ROUGH-INAND 1/2"C FROM DOOR FRAME TO CEILING BYDIVISION 26.ELECTRIC DOOR HARDWAREELECTRICAL LOCKING DEVICE AND POWERSUPPLY BY HARDWARE PROVIDER. PROVIDE120V POWER, ROUGH-IN, AND PATHWAY BYDIVISION 26.TWO-WAY COMMUNICATION / AREA-OF-REFUGECALL BOXAREA OF REFUGE TWO WAY COMMUNICATIONSYSTEM VOIP CALL STATION (FLUSH MOUNTWALL BOX). MOUNT AT +44" UNLESS OTHERWISENOTED. BASIS OF DESIGN: #RATH 2100-958NSIPOR APPROVED EQUAL. PROVIDE CAT6 CABLEROUTED BACK TO COMMAND STATION ATRECEPTION DESK ON FIRST FLOOR. PROVIDESIGNAGE AS REQUIRED BY IBC 1007.TWO-WAY COMMUNICATION / AREA-OF-REFUGECOMMAND STATIONAREA OF REFUGE TWO WAY COMMUNICATIONSYSTEM VOIP COMMAND STATION (DESK-PHONESTYLE). DEVICE SHALL BE INSTALLED ATRECEPTION DESK; FIELD COORDINATE EXACTROUGH-IN LOCATION WITH CASEWORKPROVIDER. BASIS OF DESIGN: RATH #2500-10NCVOR APPROVED EQUAL. PROVIDE CAT6 CABLEROUTED BACK TO PBX ROOM FOR VOIPCONNECTION TO NETWORK. PROVIDE SIGNAGEAS REQUIRED BY IBC 1007. COORDINATE WITHOWNER SELECTED SPECIAL SYSTEMS VENDORSFOR CONNECTION TO SECURITY AND TELECOMSYSTEMS AS REQUIRED. PROVIDE UPS BACKUPPOWER SUPPLY. BASIS OF DESIGN: RATH#RP7700104 OR APPROVED EQUAL.VESTIBULE INTERCOM STATIONVESTIBULE PUSHBUTTON INTERCOM SYSTEM.PROVIDE TWO-WAY COMMINUCATION DEVICEBETWEEN VESTIBULE AND FRONT DESK. DEVICEAT FRONT DESK SHALL BE INTEGRATED WITHSECURITY SYSTEM TO ALLOW FOR OPERATIONOF INTERIOR VESTIBULE DOOR AFTER HOURS.COORDINATE WITH OWNER FOR EXACT SYSTEMREQUIREMENTS.REQUEST TO EXIT1HHJSPECIAL BOX & RACEWAY SCHEDULESYMBOLDESCRIPTIONPRODUCTNOTESFLOOR BOX (5-GANG) LEGRAND #EFB45S (ORAPPROVED EQUAL)5-GANG RECESSED FLOOR BOX. INSTALL INFINISHED FLOOR. PROVIDE EVOLUTION SERIESSURFACE STYLE COVER AND BARRIER BETWEENPOWER AND DATA. PROVIDE RECEPTACLEDEVICES AS SHOWN ON PLANS. PROVIDEBRANCH CIRCUITING AS REQUIRED FOR POWERDEVICES SHOWN. IN ADDITION TO DEVICESSHOWN, PROVIDE (1)1"C FROM FLOOR BOXROUTED TO NEAREST ACCESSIBLE CEILINGSPACE. SEE ARCHITECTURAL PLANS FOR FLOORFINISHES AND PROVIDE ALL ACCESSORIESREQUIRED FOR INSTALLATION IN SURROUNDINGFLOOR.IN-GRADE HAND HOLE QUAZITE#PG1118DG12IN-GRADE, TIER 15, EXTERIOR-RATED, POLYMERCONCRETE BOX WITH POLYMER CONCRETE LID,BOTTOM, AND GASKETS, MOUNTED FLUSH WITHFINAL GRADE. SEE SITE DETAILS. PROVIDEBOLTED COVER #PG1118HA00## SERIES, LABELSHALL DESCRIBE INSTALLED SYSTEM, REPLACE'##' WITH:12 - COMMUNICATIONS84 - POWER29 - LIGHTING36 - SECURITYJUNCTION BOX-REQUIREMENTS AS NOTED ON PLANS.SFAAFACPFACPSBRFSHMS/CSTSFIRE ALARM SCHEDULESYMBOLDESCRIPTIONNOTEDUCT MOUNTED SMOKE DETECTORFIRE ALARM ANNUNCIATORFIRE ALARM CONTROL PANELFIRE ALARM CONTROL SUB PANELSPRINKLER ALARM BELLINTERFACE RELAYVISUAL SIGNALMOUNT AT +86" AFF TO CENTER OF DEVICE,UNLESS OTHERWISE NOTED.SPRINKLER FLOW SWITCHHEAT DETECTORHORN/STROBEMOUNT AT +86" AFF TO CENTER OF DEVICE,UNLESS OTHERWISE NOTED.MAGNETIC DOOR HOLDERMAKE CONNECTION TO MAGNETIC DOORHOLDER. DOORS TO BE HELD OPEN DURINGNORMAL OPERATION AND SHALL CLOSE UPONACTIVATION OF THE FIRE ALARM.MANUAL PULL STATIONMOUNT AT +44" AFF TO BOTTOM OF DEVICE,UNLESS OTHERWISE NOTED.COMBINATION SMOKE / CARBON MONOXIDEDETECTORSTAND-ALONE SMOKE / CARBON MONOXIDEDETECTION AND ALARM DEVICE. MOUNT WALLMOUNTED DEVICES AT +86" AFF.SMOKE DETECTORADDRESSABLE, FIRE ALARM SYSTEM INITIATIONDEVICE.TAMPER SWITCHRECEPTACLE SCHEDULESYMBOLDESCRIPTIONNOTESDUPLEX RECEPTACLENEMA 5-20RDUPLEX RECEPTACLE - CONTROLLEDNEMA 5-20R; WIRE DOWNSTREAM OFRECEPTACLE CONTROL MODULE (RCM).PROVIDE INDUSTRY STANDARD LABEL/ICONINDICATING CONTROLLED RECEPTACLE PERNEC SECTION 406.3(E).DUPLEX RECEPTACLE - GFCINEMA 5-20R, GFCIDUPLEX RECEPTACLE - GFCI/CONTROLLED NEMA 5-20R, GFCI; WIRE DOWNSTREAM OFRECEPTACLE CONTROL MODULE (RCM).PROVIDE INDUSTRY STANDARD LABEL/ICONINDICATING CONTROLLED RECEPTACLE PERNEC SECTION 406.3(E).HARDWIRED CONNECTIONCONNECTION REQUIREMENTS AS NOTED ONPLANSQUAD RECEPTACLENEMA 5-20RQUAD RECEPTACLE - CONTROLLEDNEMA 5-20R; WIRE SUCH THAT ONE DEVICE ISCONTROLLED BY RECEPTACLE CONTROLMODULE (RCM) AND ONE DEVICE ISUNSWITCHED. ON DEVICE THAT IS CONTROLLED,PROVIDE INDUSTRY STANDARD LABEL/ICONINDICATING CONTROLLED RECEPTACLE PERNEC SECTION 406.3(E).SUBSCRIPT NOTES:A: ABOVE COUNTERUSB: PROVIDE RECEPTACLE DEVICES WITH (1) USB-A AND (1) USB-C CHARGING PORTS32 MERCHANT STREET, SUITE 208HONOLULU, HI 96813808-352-5299OWNER:HOMEWOOD SUITES by HILTON SPOKANE VALLEY, WA 13515 E. Carlisle Avenue Spokane Valley, WA 99216FSC PROJECT NO. 21012PERMITDOCUMENTSMay 31, 2024GL8 MirabeauPoint, LLCTMK:PID: 45101.0401 10909 E. Pierce LaneSpokane, WA 99206(509) 919-0901Revision ScheduleNumber Description Date5915 S REGAL STREETSUITE 201SPOKANE, WA 99223PH: 509.473.9218Kelly@kwrllc.comwww.kwrllc.com5/30/2024 12:48:51 PMSTATE OF WASHINGTONREGISTERED PROFESSIONAL ENG INEER48350 KELLY A N DREW WATERMAN05.31.24ELECTRICALSYMBOLS ANDABBREVIATIONSE-0011E-701SHEET INDEXABBREVIATIONSE-001 ELECTRICAL SYMBOLS AND ABBREVIATIONSE-002 EQUIPMENT SCHEDULESE-003 EQUIPMENT SCHEDULESE-004 LUMINAIRE SCHEDULESE-005 LUMINAIRE SCHEDULESE-101 ELECTRICAL SITE PLANE-102 ELECTRICAL SITE DETAILSE-103 ELECTRICAL SITE DETAILSE-104 STORAGE SHED ENLARGED ELECTRICAL PLANE-201A FIRST FLOOR LIGHTING PLAN - AREA AE-201B FIRST FLOOR LIGHTING PLAN - AREA BE-202A SECOND FLOOR LIGHTING PLAN - AREA AE-202B SECOND FLOOR LIGHTING PLAN - AREA BE-203A THIRD FLOOR LIGHTING PLAN - AREA AE-203B THIRD FLOOR LIGHTING PLAN - AREA BE-204A FOURTH FLOOR LIGHTING PLAN - AREA AE-204B FOURTH FLOOR LIGHTING PLAN - AREA BE-205A FIFTH FLOOR LIGHTING PLAN - AREA AE-205B FIFTH FLOOR LIGHTING PLAN - AREA BE-301A FIRST FLOOR ELECTRICAL PLAN - AREA AE-301B FIRST FLOOR ELECTRICAL PLAN - AREA BE-302A SECOND FLOOR ELECTRICAL PLAN - AREA AE-302B SECOND FLOOR ELECTRICAL PLAN - AREA BE-303A THIRD FLOOR ELECTRICAL PLAN - AREA AE-303B THIRD FLOOR ELECTRICAL PLAN - AREA BE-304A FOURTH FLOOR ELECTRICAL PLAN - AREA AE-304B FOURTH FLOOR ELECTRICAL PLAN - AREA BE-305A FIFTH FLOOR ELECTRICAL PLAN - AREA AE-305B FIFTH FLOOR ELECTRICAL PLAN - AREA BE-306 OVERALL ELECTRICAL ROOF PLANE-501 ENLARGED ELECTRICAL PLANSE-502 ENLARGED ELECTRICAL PLANSE-503 ENLARGED ELECTRICAL PLANSE-504 ENLARGED POOL PHOTOMETRIC PLANE-601 POWER ONE-LINE DIAGRAME-602 POWER ONE-LINE DIAGRAME-603 PANEL SCHEDULESE-604 PANEL SCHEDULESE-605 PANEL SCHEDULESE-606 PANEL SCHEDULESE-607 PANEL SCHEDULESE-608 PANEL SCHEDULESE-609 PANEL SCHEDULESE-610 PANEL SCHEDULESE-611 PANEL SCHEDULESE-612 PANEL SCHEDULESE-701 ELECTRICAL DETAILSE-702 ELECTRICAL DETAILSGENERAL SYMBOLSAAMPEREADA AMERICANS WITH DISABILITIES ACTAFF ABOVE FINISHED FLOORAFG ABOVE FINISHED GRADEAHJ AUTHORITY HAVING JURISDICTIONAL ALUMINUMA/V AUDIO/VIDEOCB CIRCUIT BREAKERCCONDUITCO CONDUIT ONLYCU COPPERDDC DIRECT DIGITAL CONTROL SYSTEMDISC DISCONNECTDIV DIVISIONEGC EQUIPMENT GROUNDING CONDUCTOREEXISTINGEM EMERGENCYELEC ELECTRIC(AL)EXT EXTERIORFA FIRE ALARMFSD FIRE/SMOKE DAMPERGEC GROUNDING ELECTRODE CONDUCTORGND GROUNDGFCI GROUND FAULT CIRCUIT INTERRUPTERHHORIZONTALHP HORSEPOWERISP INTERNET SERVICE PROVIDERKW KILOWATT(S)kVA KILOVOLT-AMPERE(S)LM LUMEN(S)LPG LIQUEFIED PETROLEUM GASLPW LUMENS PER WATTLTG LIGHT(S), LIGHTINGMDF MAIN DISTRIBUTION FRAMEMTD MOUNTEDMVOLT MULTI-VOLTNEC NATIONAL ELECTRICAL CODENIC NOT IN CONTRACTNTS NOT TO SCALEOCP OVER-CURRENT PROTECTION / PROTECTIVE DEVICEOFCI OWNER FURNISHED, CONTRACTOR INSTALLEDOFOI OWNER FURNISHED, OWNER INSTALLEDOS OCCUPANCY SENSORPVC POLYVINYL CHLORIDEPC PHOTOCELLSPD SURGE PROTECTIVE DEVICESPEC(S) SPECIFICATION(S)SS STAINLESS STEELSUSE SUITABLE FOR USE AS SERVICE EQUIPMENTSW SWITCHTYP. TYPICALUG/E UNDERGROUND ELECTRICALUG/T UNDERGROUND TELECOMUON UNLESS OTHERWISE NOTEDWP WEATHERPROOFW WATT(S)XFMR TRANSFORMERDETAIL REFERENCE CALLOUTDETAIL NUMBERSHEET NUMBER1HG1-12CIRCUIT CALLOUTPANEL NAMECIRCUIT NUMBERFLAG NOTE INDICATORFLAG NOTE REFERENCE NUMBERSEE CORRESPONDING FLAG NOTEDESCRIPTION ON SHEETGROUNDING ELECTRODEEQUIPMENT DISCONNECT SWITCHEQUIPMENT CONNECTION / CALLOUTEQUIPMENT CALLOUTEQUIPMENT CONNECTIONHG1ELECTRICAL PANELBOARDPANEL CALLOUTMDPMAIN DISTRIBUTIONEQUIPMENT CALLOUTELECTRICAL DISTRIBUTION EQUIPMENTX1TRANSFORMER CALLOUTDRY-TYPE TRANSFORMER*ALL BRANCH CIRCUITS SHALL BE 2#12, #12GUNLESS OTHERWISE NOTEDONE-LINE CIRCUIT BREAKERONE-LINE FUSED DISCONNECT/SWITCHONE-LINE PREPARED SPACECONDUIT RISER, STUB UP/DOWN20/1250 AFOCP / POLES(I.E. 20A, 1-POLE)FRAME SIZE(I.E. 250 AMP-FRAME)VERTICAL RACEWAY /TRANSITION30/3OCP / POLES(I.E. 30A, 3-POLE)GONE-LINE GENERATOR SETNO / NC CONTACTSGENERAL NOTES1. "GENERAL NOTES" ON THIS SHEET APPLY TO ALL DRAWINGS."GENERAL NOTES" ON EACH SHEET APPLY TO ALL OF THE SHEETSON WHICH THEY OCCUR. "FLAG NOTES" APPLY ONLY WHERECALLED OUT.2. ALL EQUIPMENT SHOWN IN BOLD IS TO BE PROVIDED BYCONTRACTOR UNLESS OTHERWISE NOTED.3. CONTRACTOR SHALL PROVIDE CONDUIT AND WIRE FROM ALLCONTROL DEVICES TO LUMINAIRES FOR CONTROL OF LUMINAIRESSHOWN.4. LUMINAIRES SHOWN ON DRAWINGS FOR QUANTITY AND CIRCUITINGONLY. SEE ARCHITECTURAL REFLECTED CEILING PLANS FOR EXACTLOCATIONS.5. ALL FEEDERS AND BRANCH CIRCUITS SHALL CONTAIN ANEQUIPMENT GROUND CONDUCTOR SIZED PER NEC TABLE 250.122.FEEDERS AND BRANCH CIRCUITS OVER 100A ARE BASED ONCOPPER (CU) PER NEC TABLE 310.15(B)(16), USING 75 DEGREEAMPACITIES. FEEDERS 100A OR LESS USE 60 DEGREE C COLUMN.6. BRANCH CIRCUIT CONDUCTORS, IF NOT OTHERWISE IDENTIFIED,SHALL BE A MINIMUM #12 AWG FOR RUNS 70 FEET OR LESS, AND AMINIMUM OF #10 AWG FOR RUNS GREATER THAN 70 FEET. QUANTITYAND SIZE SHALL BE "AS REQUIRED" TO SERVE AND CONTROLDEVICE(S) OR EQUIPMENT WITH A MAXIMUM VOLTAGE DROP OFTHREE PERCENT. BRANCH CIRCUIT CONDUITS SHALL NOT CONTAINMORE THAN THREE PHASE CONDUCTORS.7. MINIMUM CONDUIT IN EXTERIOR AND UNDERGROUND LOCATIONSSHALL BE 1". MINIMUM CONDUIT FOR INTERIOR BRANCH CIRCUITSSHALL BE 3/4". CONDUITS FROM LUMINAIRES TO LOCAL USERCONTROL DEVICES (SWITCHES, OCCUPANCY SENSORS, ETC.) MAYBE 1/2" OR AS INDICATED IN SPECIFICATIONS.8. WIRING FOR EMERGENCY LIGHTING CIRCUITS OR OTHEREMERGENCY EQUIPMENT SHALL BE KEPT ENTIRELY INDEPENDENTOF ALL OTHER WIRING AND EQUIPMENT, AND SHALL MEET ALLREQUIREMENTS OF NEC SECTION NEC 700.10.9. PROVIDE DEDICATED NEUTRAL CONDUCTORS FOR ALL BRANCHCIRCUITS.10. ALL 120V DUPLEX AND QUAD RECEPTACLES SHALL BE 20A RATEDAND LISTED TAMPER-RESISTANT TYPE.11. RECEPTACLE DEVICES INSTALLED IN WET LOCATIONS OR INDICATEDWITH A 'WP' SUBSCRIPT SHALL BE LISTED AS WEATHER RESISTANTTYPE, INSTALLED WITH A WEATHERPROOF WHILE IN USE COVERWITH A HOOD THAT IS LISTED AND IDENTIFIED AS "EXTRA DUTY", INCONFORMANCE WITH NEC 406.9(B)(1).CONDUIT STUB WITHBUSHING OR CAPT3T1T1T2AAT4abaEXITT2abaT4T1T3VARIES BOTTOM OF BOX TO BE MOUNTED2" ABOVE BACKSPLASH80" 86" 18" 46" 18" 46" 18"FLOORCENTERLINE OF BOXES @DIFFERENT HEIGHTS SHALLALIGN VERTICALLY (TYP).ADJACENT PANELBOARDSSHALL HAVE MATCHINGHEIGHT DIMENSIONSELEVATIONPLANNOTES1. THIS IS A TYPICAL DETAIL, DEVICES SHOWN HERE MAY NOT BEINCLUDED IN THE PROJECT.2. A = 2" TO BOTTOM OF BOX, ABOVE COUNTER TOP ORBACKSPLASH3. MOUNTING HEIGHTS ON DRAWINGS ARE TO CENTER OF BOX.2CENTER BETWEEN TOP OF DOOR FRAMEAND CEILING (9'-0" OR LESS) OR 6" ABOVEFRAME FOR CEILING HIGHER THAN 9'-0"86"11T1T246"T2AAATSCALE:1TYPICAL MOUNTING HEIGHTS - GENERIC DETAILNOT TO SCALEEF-1OUT IN MECHANICAL EQUIPMENT SCHEDULECALLOUT EQUIPMENT DESCRIPTION VOLTAGELOAD TYPE OCP AMPS CONDUIT & WIRE CONNECTIONTYPEDISCONNECTDESCRIPTIONDISC NEMARATINGDISC BY CIRCUITNOTESAHU-01 AIR HANDLING UNIT480V 3P 4WMOTOR: 15.8 KVA 30/3 19 3/4"C,4#10,#10G HARDWIRED 3P30A, 30A FUSESNEMA 1 DIV 26 H1M-1,3,5BCU-1 BRANCH CONTROLLER 208/120V 2P 3W MOTOR: 0.17 KVA 15/2 0.83 3/4"C,3#10,#10G HARDWIRED 2-POLE MOTOR RATEDTOGGLE SWITCHNEMA 1 DIV 26 L12-9,11BCU-2 BRANCH CONTROLLER 208/120V 2P 3W MOTOR: 0.33 KVA 15/2 1.57 3/4"C,3#10,#10G HARDWIRED 2-POLE MOTOR RATEDTOGGLE SWITCHNEMA 1 DIV 26 L31-1,3CU-01A OUTDOOR CONDENSINGUNIT480V 3P 4WMOTOR: 2.49 KVA 15/3 3 3/4"C,4#12,#12G HARDWIRED 3P30A, 15A FUSESNEMA 3R DIV 26 H1M-2,4,6CU-01B OUTDOOR CONDENSINGUNIT480V 3P 4WMOTOR: 2.49 KVA 15/3 3 3/4"C,4#12,#12G HARDWIRED 3P30A, 15A FUSESNEMA 3R DIV 26 H1M-8,10,12CU-02A OUTDOOR CONDENSINGUNIT480V 3P 4WMOTOR: 29.1 KVA 50/3 35 1"C,4#6,#10G HARDWIRED 3P60A, 50A FUSESNEMA 3R DIV 26 H5M-1,3,5CU-02B OUTDOOR CONDENSINGUNIT480V 3P 4WMOTOR: 29.1 KVA 50/3 35 1"C,4#6,#10G HARDWIRED 3P60A, 50A FUSESNEMA 3R DIV 26 H5M-7,9,11CU-03A OUTDOOR CONDENSINGUNIT480V 3P 4WMOTOR: 20.78 KVA 40/3 25 3/4"C,4#8,#10G HARDWIRED 3P60A, 40A FUSESNEMA 3R DIV 26 H5M-2,4,6CU-03B OUTDOOR CONDENSINGUNIT480V 3P 4WMOTOR: 20.78 KVA 40/3 25 3/4"C,4#8,#10G HARDWIRED 3P60A, 40A FUSESNEMA 3R DIV 26 H5M-8,10,12CU-04 OUTDOOR CONDENSINGUNIT208V 3P 4WMOTOR: 3.96 KVA 25/3 11 3/4"C,4#12,#12G HARDWIRED 3P30A, 25A FUSESNEMA 3R DIV 26 L51-5,7,9CU-05 OUTDOOR CONDENSINGUNIT208V 3P 4WMOTOR: 3.96 KVA 25/3 11 3/4"C,4#10,#10G HARDWIRED 3P30A, 25A FUSESNEMA 3R DIV 26 L51-11,13,15DH-01 DUCT HEATER120V 1P 2WHEATING: 0.24 KVA 20/1 2 3/4"C,2#12,#12G HARDWIRED LOCKABLE CIRCUITBREAKERN/ADIV 26 L12-6 PROVIDE LOCKABLE CIRCUITBREAKER.DHWP-1 DOMESTIC HOT WATERPUMP120V 1P 2WMOTOR: 0.58 KVA20/1 4.8 3/4"C,2#12,#12G HARDWIRED MOTOR RATEDTOGGLE SWITCHNEMA 1 DIV 26 L12-10DHWP-2 DOMESTIC HOT WATERPUMP120V 1P 2WMOTOR: 0.12 KVA20/1 1 3/4"C,2#12,#12G HARDWIRED MOTOR RATEDTOGGLE SWITCHNEMA 1 DIV 26 L12-12EF-01 EXHAUST FAN208/120V 2P 3W MOTOR: 2 HP20/2 13.85 3/4"C,3#10,#10G HARDWIRED 2-POLE 30A MOTORRATED TOGGLESWITCHNEMA 3R DIV 26 L21-8,10 PROVIDE 120V CONNECTIONFOR ASSOCIATED DAMPERACTUATOR.EF-02 EXHAUST FAN120V 1P 2WMOTOR: 1/10 HP20/1 3.5 3/4"C,2#10,#10G HARDWIRED MOTOR RATEDTOGGLE SWITCHNEMA 3R DIV 26 L21-12 PROVIDE 120V CONNECTIONFOR ASSOCIATED DAMPERACTUATOR.EF-03 KITCHEN HOOD EXHAUSTFAN208/120V 2P 3W KITCHEN: 3/4 HP15/2 7.96 3/4"C,3#12,#12G HARDWIRED 2P30A, 15A FUSESNEMA 3R DIV 26 L1KA-38,40 ROUTE BRANCH CIRCUITTHROUGH KITCHEN HOODANSUL PANEL. SEE HOOD SHOPDRAWINGS AND COORDINATEWITH HOOD EQUIPMENTPROVIDER FOR EXACTREQUIREMENTS. FIELD VERIFYCONNECTION LOCATION ANDDISCONNECT MOUNTINGLCOATION.EH-11 ELECTRIC HEATER120V 1P 2WHEATING: 1 KVA20/1 8.33 3/4"C,2#12,#12G HARDWIRED LOCKABLE CIRCUITBREAKERN/ADIV 26 L12-14 PROVIDE LOCKABLE CIRCUITBREAKER.EH-12 ELECTRIC HEATER120V 1P 2WHEATING: 1 KVA20/1 8.33 3/4"C,2#12,#12G HARDWIRED LOCKABLE CIRCUITBREAKERN/ADIV 26 L14A-5 PROVIDE LOCKABLE CIRCUITBREAKER.EH-21 ELECTRIC HEATER120V 1P 2WHEATING: 1 KVA20/1 8.33 3/4"C,2#12,#12G HARDWIRED LOCKABLE CIRCUITBREAKERN/ADIV 26 L21-2 PROVIDE LOCKABLE CIRCUITBREAKER.EH-22 ELECTRIC HEATER120V 1P 2WHEATING: 1 KVA20/1 8.33 3/4"C,2#10,#10G HARDWIRED LOCKABLE CIRCUITBREAKERN/ADIV 26 L21-4 PROVIDE LOCKABLE CIRCUITBREAKER.EH-31 ELECTRIC HEATER120V 1P 2WHEATING: 1 KVA20/1 8.33 3/4"C,2#12,#12G HARDWIRED LOCKABLE CIRCUITBREAKERN/ADIV 26 L31-2 PROVIDE LOCKABLE CIRCUITBREAKER.EH-32 ELECTRIC HEATER120V 1P 2WHEATING: 1 KVA20/1 8.33 3/4"C,2#10,#10G HARDWIRED LOCKABLE CIRCUITBREAKERN/ADIV 26 L31-4 PROVIDE LOCKABLE CIRCUITBREAKER.EH-41 ELECTRIC HEATER120V 1P 2WHEATING: 1 KVA20/1 8.33 3/4"C,2#12,#12G HARDWIRED LOCKABLE CIRCUITBREAKERN/ADIV 26 L41-2 PROVIDE LOCKABLE CIRCUITBREAKER.EH-42 ELECTRIC HEATER120V 1P 2WHEATING: 1 KVA20/1 8.33 3/4"C,2#10,#10G HARDWIRED LOCKABLE CIRCUITBREAKERN/ADIV 26 L41-4 PROVIDE LOCKABLE CIRCUITBREAKER.EH-51 ELECTRIC HEATER120V 1P 2WHEATING: 1 KVA20/1 8.33 3/4"C,2#12,#12G HARDWIRED LOCKABLE CIRCUITBREAKERN/ADIV 26 L51-2 PROVIDE LOCKABLE CIRCUITBREAKER.EH-52 ELECTRIC HEATER120V 1P 2WHEATING: 1 KVA20/1 8.33 3/4"C,2#10,#10G HARDWIRED LOCKABLE CIRCUITBREAKERN/ADIV 26 L51-4 PROVIDE LOCKABLE CIRCUITBREAKER.ERV-01 ENERGY RECOVERYVENTILATOR480V 3P 4WMOTOR: 33.26 KVA 60/3 401"C,4#6,#8G HARDWIRED 3P60A, 60A FUSESNEMA 3R DIV 26 H5M-13,15,17FCU-211 INDOOR FAN COIL208/120V 2P 3W MOTOR: 0.88 KVA 15/2 4.25 3/4"C,3#10,#10G HARDWIRED 2-POLE MOTOR RATEDTOGGLE SWITCHNEMA 1 DIV 26 L12-9,11FCU-212 INDOOR FAN COIL208/120V 2P 3W MOTOR: 0.6 KVA15/2 2.88 3/4"C,3#10,#10G HARDWIRED 2-POLE MOTOR RATEDTOGGLE SWITCHNEMA 1 DIV 26 L12-9,11FCU-213 INDOOR FAN COIL208/120V 2P 3W MOTOR: 0.91 KVA 15/2 4.38 3/4"C,3#10,#10G HARDWIRED 2-POLE MOTOR RATEDTOGGLE SWITCHNEMA 1 DIV 26 L12-16,18FCU-214 INDOOR FAN COIL208/120V 2P 3W MOTOR: 0.88 KVA 15/2 4.25 3/4"C,3#10,#10G HARDWIRED 2-POLE MOTOR RATEDTOGGLE SWITCHNEMA 1 DIV 26 L12-16,18FCU-215 INDOOR FAN COIL208/120V 2P 3W MOTOR: 1.71 KVA 15/2 8.2 3/4"C,3#10,#10G HARDWIRED 2-POLE MOTOR RATEDTOGGLE SWITCHNEMA 1 DIV 26 L14A-1,3FCU-216 INDOOR FAN COIL208/120V 2P 3W MOTOR: 0.44 KVA 15/2 2.13 3/4"C,3#10,#10G HARDWIRED 2-POLE MOTOR RATEDTOGGLE SWITCHNEMA 1 DIV 26 L14A-1,3FCU-217 INDOOR FAN COIL208/120V 2P 3W MOTOR: 0.6 KVA15/2 2.88 3/4"C,3#10,#10G HARDWIRED 2-POLE MOTOR RATEDTOGGLE SWITCHNEMA 1 DIV 26 L14A-1,3FCU-311 INDOOR FAN COIL208/120V 2P 3W MOTOR: 0.05 KVA 15/2 0.24 3/4"C,3#10,#10G HARDWIRED 2-POLE MOTOR RATEDTOGGLE SWITCHNEMA 1 DIV 26 L12-16,18FCU-321 INDOOR FAN COIL208/120V 2P 3W MOTOR: 0.05 KVA 15/2 0.24 3/4"C,3#10,#10G HARDWIRED 2-POLE MOTOR RATEDTOGGLE SWITCHNEMA 1 DIV 26 L21-1,3FCU-322 INDOOR FAN COIL208/120V 2P 3W MOTOR: 0.05 KVA 15/2 0.24 3/4"C,3#10,#10G HARDWIRED 2-POLE MOTOR RATEDTOGGLE SWITCHNEMA 1 DIV 26 L21-1,3FCU-323 INDOOR FAN COIL208/120V 2P 3W MOTOR: 0.06 KVA 15/2 0.29 3/4"C,3#10,#10G HARDWIRED 2-POLE MOTOR RATEDTOGGLE SWITCHNEMA 1 DIV 26 L21-1,3FCU-324 INDOOR FAN COIL208/120V 2P 3W MOTOR: 0.05 KVA 15/2 0.24 3/4"C,3#10,#10G HARDWIRED 2-POLE MOTOR RATEDTOGGLE SWITCHNEMA 1 DIV 26 L21-1,3FCU-325 INDOOR FAN COIL208/120V 2P 3W MOTOR: 0.05 KVA 15/2 0.24 3/4"C,3#10,#10G HARDWIRED 2-POLE MOTOR RATEDTOGGLE SWITCHNEMA 1 DIV 26 L21-1,3FCU-326 INDOOR FAN COIL208/120V 2P 3W MOTOR: 0.36 KVA 15/2 1.75 3/4"C,3#10,#10G HARDWIRED 2-POLE MOTOR RATEDTOGGLE SWITCHNEMA 1 DIV 26 L21-1,3FCU-331 INDOOR FAN COIL208/120V 2P 3W MOTOR: 0.05 KVA 15/2 0.24 3/4"C,3#10,#10G HARDWIRED 2-POLE MOTOR RATEDTOGGLE SWITCHNEMA 1 DIV 26 L31-1,3FCU-332 INDOOR FAN COIL208/120V 2P 3W MOTOR: 0.06 KVA 15/2 0.29 3/4"C,3#10,#10G HARDWIRED 2-POLE MOTOR RATEDTOGGLE SWITCHNEMA 1 DIV 26 L31-1,3FCU-333 INDOOR FAN COIL208/120V 2P 3W MOTOR: 0.05 KVA 15/2 0.24 3/4"C,3#10,#10G HARDWIRED 2-POLE MOTOR RATEDTOGGLE SWITCHNEMA 1 DIV 26 L31-1,3FCU-334 INDOOR FAN COIL208/120V 2P 3W MOTOR: 0.05 KVA 15/2 0.24 3/4"C,3#10,#10G HARDWIRED 2-POLE MOTOR RATEDTOGGLE SWITCHNEMA 1 DIV 26 L31-1,3FCU-335 INDOOR FAN COIL208/120V 2P 3W MOTOR: 0.36 KVA 15/2 1.75 3/4"C,3#10,#10G HARDWIRED 2-POLE MOTOR RATEDTOGGLE SWITCHNEMA 1 DIV 26 L31-1,3FCU-341 INDOOR FAN COIL208/120V 2P 3W MOTOR: 0.05 KVA 15/2 0.24 3/4"C,3#10,#10G HARDWIRED 2-POLE MOTOR RATEDTOGGLE SWITCHNEMA 1 DIV 26 L41-1,3FCU-342 INDOOR FAN COIL208/120V 2P 3W MOTOR: 0.06 KVA 15/2 0.29 3/4"C,3#10,#10G HARDWIRED 2-POLE MOTOR RATEDTOGGLE SWITCHNEMA 1 DIV 26 L41-1,3FCU-343 INDOOR FAN COIL208/120V 2P 3W MOTOR: 0.05 KVA 15/2 0.24 3/4"C,3#10,#10G HARDWIRED 2-POLE MOTOR RATEDTOGGLE SWITCHNEMA 1 DIV 26 L41-1,3FCU-344 INDOOR FAN COIL208/120V 2P 3W MOTOR: 0.05 KVA 15/2 0.24 3/4"C,3#10,#10G HARDWIRED 2-POLE MOTOR RATEDTOGGLE SWITCHNEMA 1 DIV 26 L41-1,3MECHANICAL EQUIPMENT SCHEDULE (CONT.)CALLOUT EQUIPMENT DESCRIPTION VOLTAGELOAD TYPE OCP AMPS CONDUIT & WIRE CONNECTIONTYPEDISCONNECTDESCRIPTIONDISC NEMARATINGDISC BY CIRCUITNOTESFCU-345 INDOOR FAN COIL208/120V 2P 3W MOTOR: 0.36 KVA 15/2 1.75 3/4"C,3#10,#10G HARDWIRED 2-POLE MOTOR RATEDTOGGLE SWITCHNEMA 1 DIV 26 L41-1,3FCU-351 INDOOR FAN COIL208/120V 2P 3W MOTOR: 0.05 KVA 15/2 0.24 3/4"C,3#10,#10G HARDWIRED 2-POLE MOTOR RATEDTOGGLE SWITCHNEMA 1 DIV 26 L51-1,3FCU-352 INDOOR FAN COIL208/120V 2P 3W MOTOR: 0.06 KVA 15/2 0.29 3/4"C,3#10,#10G HARDWIRED 2-POLE MOTOR RATEDTOGGLE SWITCHNEMA 1 DIV 26 L51-1,3FCU-353 INDOOR FAN COIL208/120V 2P 3W MOTOR: 0.05 KVA 15/2 0.24 3/4"C,3#10,#10G HARDWIRED 2-POLE MOTOR RATEDTOGGLE SWITCHNEMA 1 DIV 26 L51-1,3FCU-354 INDOOR FAN COIL208/120V 2P 3W MOTOR: 0.05 KVA 15/2 0.24 3/4"C,3#10,#10G HARDWIRED 2-POLE MOTOR RATEDTOGGLE SWITCHNEMA 1 DIV 26 L51-1,3FCU-355 INDOOR FAN COIL208/120V 2P 3W MOTOR: 0.36 KVA 15/2 1.75 3/4"C,3#10,#10G HARDWIRED 2-POLE MOTOR RATEDTOGGLE SWITCHNEMA 1 DIV 26 L51-1,3FCU-421 INDOOR FAN COIL208/120V 2P 3W MOTOR: 0.6 KVA15/2 2.88 3/4"C,3#10,#10G HARDWIRED 2-POLE MOTOR RATEDTOGGLE SWITCHNEMA 1 DIV 26 L21-1,3FCU-500 INDOOR FAN COIL208/120V 2P 3W MOTOR: 0.6 KVA15/2 2.88 3/4"C,3#10,#10G HARDWIRED 2-POLE MOTOR RATEDTOGGLE SWITCHNEMA 1 DIV 26 L51-1,3H-1 KITCHEN HOOD 1ELECTRICAL120V 1P 2WLIGHTING: 1.8 KVA 20/1 15 3/4"C,2#12,#12G HARDWIRED LOCKABLE CIRCUITBREAKERN/ADIV 26 L1KA-28 PROVIDE 20A HOOD MOUNTEDSWITCH TO CONTROL HOODLIGHTS. COORDINATE WITHEQUIPMENT PROVIDER FORALL CONTROL WIRING ASREQUIRED.H-1.1 KITCHEN HOOD FIRESUPRESSION SYSTEM(ANSUL PANEL)120V 1P 2WNONCONTINUOUS: 0.5KVA20/1 4.17 3/4"C,2#12,#12G HARDWIRED LOCKABLE CIRCUITBREAKERN/ADIV 26 L1KA-30 PROVIDE LOCKABLE CIRCUITBREAKER WITH RED HANDLE.MAU-01 MAKEUP AIR UNIT208V 3P 4WKITCHEN: 1.12 KVA 15/3 3.1 3/4"C,4#12,#12G HARDWIRED 3P30A, 15A FUSESNEMA 1 DIV 26 L1KA-32,34,36 ROUTE BRANCH CIRCUITTHROUGH KITCHEN HOODANSUL PANEL. SEE HOOD SHOPDRAWINGS AND COORDINATEWITH HOOD EQUIPMENTPROVIDER FOR EXACTREQUIREMENTS. FIELDCOORDINATE CONNECTLOCATION AND DISCONNECTMOUNTING LOCATION.SP-1 SUMP PUMP120V 1P 2WMOTOR: 1/2 HP20/1 9.8 3/4"C,2#10,#10G HARDWIRED MOTOR RATEDTOGGLE SWITCHNEMA 4X DIV 26 ELEV-2SP-2 SUMP PUMP120V 1P 2WMOTOR: 1/2 HP20/1 9.8 3/4"C,2#10,#10G HARDWIRED MOTOR RATEDTOGGLE SWITCHNEMA 4X DIV 26 ELEV-4UH-01 ELECTRIC UNIT HEATER 208V 2P 2WMOTOR: 5.64 KVA 35/2 27.1 3/4"C,2#8,#10G HARDWIRED LOCKABLE CIRCUITBREAKERN/ADIV 26 L12-2,4 PROVIDE LOCKABLE CIRCUITBREAKER.UH-02 ELECTRIC UNIT HEATER 208V 2P 2WMOTOR: 3.74 KVA 30/2 18 3/4"C,2#10,#10G HARDWIRED LOCKABLE CIRCUITBREAKERN/ADIV 26 LSS-5,7 PROVIDE LOCKABLE CIRCUITBREAKER.WH-1 GAS WATER HEATER 120V 1P 2WHEATING: 0.6 KVA 20/1 5 3/4"C,2#10,#10G HARDWIRED LOCKABLE CIRCUITBREAKERN/ADIV 26 L12-1 PROVIDE LOCKABLE CIRCUITBREAKER.WH-2 GAS WATER HEATER 120V 1P 2WHEATING: 0.6 KVA 20/1 5 3/4"C,2#10,#10G HARDWIRED LOCKABLE CIRCUITBREAKERN/ADIV 26 L12-3 PROVIDE LOCKABLE CIRCUITBREAKER.WH-3 GAS WATER HEATER 120V 1P 2WHEATING: 0.6 KVA 20/1 5 3/4"C,2#10,#10G HARDWIRED LOCKABLE CIRCUITBREAKERN/ADIV 26 L12-5 PROVIDE LOCKABLE CIRCUITBREAKER.WH-4 GAS WATER HEATER 120V 1P 2WHEATING: 0.6 KVA 20/1 5 3/4"C,2#10,#10G HARDWIRED LOCKABLE CIRCUITBREAKERN/ADIV 26 L12-7 PROVIDE LOCKABLE CIRCUITBREAKER.WS-01 WATER SOFTENER120V 1P 2WMOTOR: 1.8 KVA20/1 15 3/4"C,2#12,#12G RECEPTACLE NEMA 5-20RN/ADIV 26 L12-8EQUIPMENT SCHEDULECALLOUT EQUIPMENT DESCRIPTION VOLTAGELOAD TYPEOCP AMPS CONDUIT & WIRE CONNECTIONTYPEDISCONNECTDESCRIPTIONDISC NEMARATINGDISC BY CIRCUITNOTESCOPY-1 COPIER120V 1P 2WNONCONTINUOUS: 1.2 KVA 20/1 10 3/4"C,2#12,#12G RECEPTACLE NEMA 5-20RN/ADIV 26 L14A-6DF-1 DRINKINGFOUNTAIN/BOTTLE FILLER120V 1P 2WNONCONTINUOUS: 0.72 KVA 20/1 6 3/4"C,2#10,#10G RECEPTACLE NEMA 5-20RN/ADIV 26 L11-40 PROVIDE GFCI CIRCUITBREAKER WITH 6mA TRIP.DF-2 DRINKINGFOUNTAIN/BOTTLE FILLER120V 1P 2WNONCONTINUOUS: 0.72 KVA 20/1 6 3/4"C,2#10,#10G RECEPTACLE NEMA 5-20RN/ADIV 26 L14A-2 PROVIDE GFCI CIRCUITBREAKER WITH 6mA TRIP.DW-1 DISHWASHER120V 1P 2WKITCHEN: 1.2 KVA20/1 10 3/4"C,2#10,#10G RECEPTACLE NEMA 5-20RN/ADIV 26 L11-29 PROVIDE GFCI CIRCUITBREAKER WITH 6mA TRIP.FP-1 FLAG POLE120V 1P 2WLIGHTING: 0.01 KVA20/1 0.1 3/4"C,2#10,#10G HARDWIRED LOCKABLECIRCUITBREAKERN/ADIV 26 L12-17 ROUTE BRANCH CIRCUIT VIACONTROL MODULE, SHOWN ONSHEET E-301A, FOR TIMECLOCKCONTROL.FP-2 FLAG POLE120V 1P 2WLIGHTING: 0.01 KVA20/1 0.1 3/4"C,2#10,#10G HARDWIRED LOCKABLECIRCUITBREAKERN/ADIV 26 L12-17 SEE FP-1 FOR ADDITIONALADDITIONAL INFORMATION ONFLAG POLE LIGHTINGREQUIREMENTS.FP-3 FLAG POLE120V 1P 2WLIGHTING: 0.01 KVA20/1 0.1 3/4"C,2#10,#10G HARDWIRED LOCKABLECIRCUITBREAKERN/ADIV 26 L12-17 SEE FP-1 FOR ADDITIONALADDITIONAL INFORMATION ONFLAG POLE LIGHTINGREQUIREMENTS.ICE-1 ICE MACHINE120V 1P 2WMOTOR: 0.19 KVA20/1 1.6 3/4"C,2#10,#10G RECEPTACLE NEMA 5-20RN/ADIV 26 L11-38 PROVIDE GFCI CIRCUITBREAKER WITH 6mA TRIP.MW-1 MICROWAVE120V 1P 2WNONCONTINUOUS: 1 KVA20/1 8.33 3/4"C,2#10,#10G RECEPTACLE NEMA 5-20RN/ADIV 26 L11-31 PROVIDE GFCI CIRCUITBREAKER WITH 6mA TRIP.PRINT-1 COPIER120V 1P 2WNONCONTINUOUS: 0.6 KVA 20/1 5 3/4"C,2#10,#10G RECEPTACLE NEMA 5-20RN/ADIV 26 L14A-4REF-1 REFRIGERATOR120V 1P 2WNONCONTINUOUS: 0.8 KVA 20/1 6.67 3/4"C,2#10,#10G RECEPTACLE NEMA 5-20RN/ADIV 26 L11-27 PROVIDE GFCI CIRCUITBREAKER WITH 6mA TRIP.32 MERCHANT STREET, SUITE 208HONOLULU, HI 96813808-352-5299OWNER:HOMEWOOD SUITES by HILTON SPOKANE VALLEY, WA 13515 E. Carlisle Avenue Spokane Valley, WA 99216FSC PROJECT NO. 21012PERMITDOCUMENTSMay 31, 2024GL8 MirabeauPoint, LLCTMK:PID: 45101.0401 10909 E. Pierce LaneSpokane, WA 99206(509) 919-0901Revision ScheduleNumber Description Date5915 S REGAL STREETSUITE 201SPOKANE, WA 99223PH: 509.473.9218Kelly@kwrllc.comwww.kwrllc.com5/30/2024 12:48:56 PMSTATE OF WASHINGTONREGISTERED PROFESSIONAL ENG INEER48350 KELLY A N DREW WATERMAN05.31.24EQUIPMENTSCHEDULESE-002 FITNESS EQUIPMENT SCHEDULECALLOUT EQUIPMENT DESCRIPTION VOLTAGELOAD TYPEOCP AMPS CONDUIT & WIRE CONNECTIONTYPEDISCONNECTDESCRIPTIONDISC NEMARATINGDISC BY CIRCUITNOTESBIKE-1 PELOTON BIKE120V 1P 2WMOTOR: 0.18 KVA20/1 1.5 3/4"C,2#10,#10G RECEPTACLE NEMA 5-20RN/ADIV 26 L11-36ELLIP-1 ELLIPTICAL120V 1P 2WMOTOR: 0.18 KVA20/1 1.5 3/4"C,2#10,#10G RECEPTACLE NEMA 5-20RN/ADIV 26 L11-36ELLIP-2 ELLIPTICAL120V 1P 2WMOTOR: 0.18 KVA20/1 1.5 3/4"C,2#10,#10G RECEPTACLE NEMA 5-20RN/ADIV 26 L11-36TREAD-1 TREADMILL120V 1P 2WMOTOR: 0.6 KVA20/1 5 3/4"C,2#10,#10G RECEPTACLE NEMA 5-20RN/ADIV 26 L11-33TREAD-2 TREADMILL120V 1P 2WMOTOR: 0.6 KVA20/1 5 3/4"C,2#10,#10G RECEPTACLE NEMA 5-20RN/ADIV 26 L11-35TREAD-3 TREADMILL120V 1P 2WMOTOR: 0.6 KVA20/1 5 3/4"C,2#10,#10G RECEPTACLE NEMA 5-20RN/ADIV 26 L11-37TREAD-4 TREADMILL120V 1P 2WMOTOR: 0.6 KVA20/1 5 3/4"C,2#10,#10G RECEPTACLE NEMA 5-20RN/ADIV 26 L11-39GUEST UNIT EQUIPMENT SCHEDULECALLOUT EQUIPMENT DESCRIPTION VOLTAGELOAD TYPEOCP AMPS CONDUIT & WIRE CONNECTIONTYPEDISCONNECTDESCRIPTIONDISC NEMARATINGDISC BYNOTESCOOK-2 GUEST UNIT INDUCTIONCOOKTOP, 2-BURNER208/120V 2P 3W NONCONTINUOUS: 3 KVA20/2 14.42 3/4"C,3#12,#12G HARDWIRED LOCKABLECIRCUITBREAKERN/ADIV 26 PROVIDE LOCKABLE CIRCUIT BREAKER.COOK-4 GUEST UNIT INDUCTIONCOOKTOP, 4-BURNER208/120V 2P 3W NONCONTINUOUS: 6.24 KVA 30/2 30 3/4"C,3#10,#10G HARDWIRED LOCKABLECIRCUITBREAKERN/ADIV 26 PROVIDE LOCKABLE CIRCUIT BREAKER.DRY GUEST UNIT DRYINGMACHINE208/120V 2P 3W NONCONTINUOUS: 5 KVA30/2 24.04 3#10,#10G RECEPTACLE NEMA 14-30R N/ADIV 26 PROVIDE GFCI CIRCUIT BREAKER WITH 6mATRIP.DW GUEST UNIT DISHWASHER 120V 1P 2WNONCONTINUOUS: 0.8 KVA 20/1 6.67 3/4"C,2#12,#12G RECEPTACLE NEMA 5-20RN/ADIV 26 PROVIDE COMBINATION AFCI/GFCI CIRCUITBREAKER WITH 6mA TRIP.GD GUEST UNIT GARBAGEDISPOSAL120V 1P 2WNONCONTINUOUS: 1/3 HP20/1 7.2 3/4"C,2#12,#12G RECEPTACLE NEMA 5-20RN/ADIV 26 PROVIDE COMBINATION AFCI/GFCI CIRCUITBREAKER WITH 6mA TRIP.HOOD GUEST UNIT COOKTOPHOOD120V 1P 2WNONCONTINUOUS: 0.17 KVA 20/1 1.4 3/4"C,2#12,#12G RECEPTACLE NEMA 5-20RN/ADIV 26 PROVIDE COMBINATION AFCI/GFCI CIRCUITBREAKER WITH 6mA TRIP.MW GUEST UNIT MICROWAVE 120V 1P 2WNONCONTINUOUS: 1 KVA20/1 8.33 3/4"C,2#12,#12G RECEPTACLE NEMA 5-20RN/ADIV 26 PROVIDE COMBINATION AFCI/GFCI CIRCUITBREAKER WITH 6mA TRIP.MW/HOOD COMBINATION GUEST UNITMICROWAVE/HOOD120V 1P 2WNONCONTINUOUS: 1 KVA20/1 8.33 3/4"C,2#12,#12G RECEPTACLE NEMA 5-20RN/ADIV 26 COMBINATION MICROWAVE/HOOD WITHINTEGRAL CONTROLS. PROVIDE COMBINATIONAFCI/GFCI CIRCUIT BREAKER WITH 6mA TRIP.PTAC-01 GUEST UNIT PTAC208/120V 2P 3W NONCONTINUOUS: 2.93 KVA 20/2 14.1 3/4"C,3#12,#12G RECEPTACLE NEMA 6-20RN/ADIV 26 VERIFY RECEPTACLE CONFIGURATION ANDMOUNTING LOCATION WITH MECHANICAL PRIORTO ROUGH-IN.REF GUEST UNITREFRIGERATOR120V 1P 2WNONCONTINUOUS: 0.18 KVA 20/1 1.5 3/4"C,2#12,#12G RECEPTACLE NEMA 5-20RN/ADIV 26 PROVIDE COMBINATION AFCI/GFCI CIRCUITBREAKER WITH 6mA TRIP.WASH GUEST UNIT WASHMACHINE120V 1P 2WNONCONTINUOUS: 1.2 KVA 20/1 10 3/4"C,2#12,#12G RECEPTACLE NEMA 5-20RN/ADIV 26 PROVIDE COMBINATION AFCI/GFCI CIRCUITBREAKER WITH 6mA TRIP.NOTE: EQUIPMENT IS TYPICAL FOR TYPICAL GUEST UNIT TYPES. SEE SHEETS E-502, E-503, AND E-504 FOR TYPICAL LOCATIONS AND ADDITIONAL INFORMATION. SEE ARCHITECTURAL PLANS FOR QUANTITIES AND LOCATIONS OF TYPICAL UNIT TYPES.KITCHEN EQUIPMENT SCHEDULECALLOUT EQUIPMENT DESCRIPTION VOLTAGELOAD TYPE OCP AMPS CONDUIT & WIRE CONNECTIONTYPEDISCONNECTDESCRIPTIONDISC NEMARATINGDISC BY CIRCUITNOTESKE-2 BEER GLYCOL SYSTEM 120V 1P 2WKITCHEN: 1/3 HP20/1 7.2 3/4"C,2#12,#12G RECEPTACLE NEMA 5-20RN/ADIV 26 L1KA-5 PROVIDE GFCI CIRCUITBREAKER WITH 6mA TRIP.KE-2.1 TAP WALL UPS120V 1P 2WKITCHEN: 0.24 KVA 20/1 2 3/4"C,2#12,#12G RECEPTACLE NEMA 5-20RN/ADIV 26 L1KA-1 PROVIDE GFCI CIRCUITBREAKER WITH 6mA TRIP.KE-2.2 DRAFT BEER COOLER 120V 1P 2WKITCHEN: 0.78 KVA 20/1 6.5 3/4"C,2#12,#12G RECEPTACLE NEMA 5-20RN/ADIV 26 L1KA-3 PROVIDE GFCI CIRCUITBREAKER WITH 6mA TRIP.KE-7 WALK-IN COOLER LIGHTS 120V 1P 2WLIGHTING: 0.6 KVA 20/1 5 3/4"C,2#12,#12G HARDWIRED LOCKABLE CIRCUITBREAKERN/ADIV 26 L1KA-17 CONTRACTOR TO MOUNT ANDINSTALL VAPOR-PROOF LIGHTS,FURNISHED BY KITCHENEQUIPMENT PROVIDER.PROVIDE CONNECTION ABOVECOOLER BOX. VERIFY EXACTLOCATION WITH EQUIPMENTPROVIDER.KE-7.1 WALK-IN COOLEREVAPORATION COIL120V 1P 2WMOTOR: 0.19 KVA20/1 1.6 3/4"C,2#12,#12G HARDWIRED MOTOR RATEDTOGGLE SWITCHNEMA 4X DIV 26 L1KA-19 FIELD VERIFY CONNECTIONLOCATION AND DISCONNECTMOUNTING LOCATION.KE-7.2 WALK-IN COOLERCONDENSING UNIT208/120V 2P 3W MOTOR: 1.58 KVA 15/2 7.6 3/4"C,3#10,#10G HARDWIRED 2P30A, NON-FUSED NEMA 3R DIV 26 L51-17,19 FIELD VERIFY CONNECTIONLOCATION AND DISCONNECTMOUNTING LOCATION.KE-20 DISPOSER208/120V 2P 3W KITCHEN: 1.81 KVA 20/2 8.7 3/4"C,3#12,#12G HARDWIRED LOCKABLE CIRCUITBREAKERN/ADIV 26 L1KA-13,15 FIELD COORDINATE WIRINGWITH WATER CONTROLCENTER.KE-22A UNDERCOUNTERDISHWASHER208V 3P 4WKITCHEN: 7.93 KVA 30/3 22 3/4"C,4#10,#10G HARDWIRED LOCKABLE CIRCUITBREAKERN/ADIV 26 L1KA-10,12,14 PROVIDE LOCKABLE GFCICIRCUIT BREAKER.KE-22B UNDERCOUNTERDISHWASHER208V 3P 4WKITCHEN: 7.93 KVA 30/3 22 3/4"C,4#10,#10G HARDWIRED LOCKABLE CIRCUITBREAKERN/ADIV 26 L1KA-4,6,8 PROVIDE LOCKABLE GFCICIRCUIT BREAKER.KE-26 NUGGET ICE MAKER 120V 1P 2WKITCHEN: 1.3 KVA 15/1 10.8 3/4"C,2#12,#12G RECEPTACLE NEMA 5-20RN/ADIV 26 L1KA-2 PROVIDE GFCI CIRCUITBREAKER WITH 6mA TRIP.KE-29 WAFFLE MAKER120V 1P 2WKITCHEN: 1.3 KVA 20/1 10.83 3/4"C,2#12,#12G RECEPTACLE NEMA 5-20R, GFCIN/ADIV 26 L1KA-24KE-30 JUICE DISPENSER120V 1P 2WKITCHEN: 0.96 KVA 20/1 8 3/4"C,2#12,#12G RECEPTACLE NEMA 5-20R, GFCIN/ADIV 26 L1KA-18KE-31 REFRIGERATED WORK TOP 120V 1P 2WKITCHEN: 0.36 KVA 20/1 3 3/4"C,2#12,#12G RECEPTACLE NEMA 5-20RN/ADIV 26 L1KA-11 PROVIDE GFCI CIRCUITBREAKER WITH 6mA TRIP.KE-41 REACH-IN FREEZER120V 1P 2WKITCHEN: 1.44 KVA 20/1 12 3/4"C,2#12,#12G RECEPTACLE NEMA 5-20RN/ADIV 26 L1KA-7 PROVIDE GFCI CIRCUITBREAKER WITH 6mA TRIP.KE-42A CONVECTION OVEN208/120V 2P 3W KITCHEN: 5.82 KVA 30/2 28 3/4"C,3#10,#10G HARDWIRED LOCKABLE CIRCUITBREAKERN/ADIV 26 L1KB-9,11 PROVIDE LOCKABLE CIRCUITBREAKER.KE-42B CONVECTION PROOFER 120V 1P 2WKITCHEN: 1.39 KVA 20/1 11.6 3/4"C,2#12,#12G RECEPTACLE NEMA 5-20RN/ADIV 26 L1KB-1 PROVIDE GFCI CIRCUITBREAKER WITH 6mA TRIP.KE-47 PASTA COOKER208/120V 2P 3W KITCHEN: 2.7 KVA 20/2 12.98 3/4"C,3#12,#12G RECEPTACLE NEMA 6-20RN/ADIV 26 L1KB-14,16 PROVIDE GFCI CIRCUITBREAKER WITH 6mA TRIP.KE-48 REFRIGERATED WORK TOP 120V 1P 2WKITCHEN: 0.36 KVA 20/1 3 3/4"C,2#12,#12G RECEPTACLE NEMA 5-20RN/ADIV 26 L1KB-5 PROVIDE GFCI CIRCUITBREAKER WITH 6mA TRIP.KE-49A INDUCTION RANGE208/120V 2P 3W KITCHEN: 2.6 KVA 20/2 12.5 3/4"C,3#12,#12G RECEPTACLE NEMA 6-20RN/ADIV 26 L1KB-8,10 PROVIDE GFCI CIRCUITBREAKER WITH 6mA TRIP.KE-49B INDUCTION RANGE208/120V 2P 3W KITCHEN: 2.6 KVA 20/2 12.5 3/4"C,3#12,#12G RECEPTACLE NEMA 6-20RN/ADIV 26 L1KB-2,4 PROVIDE GFCI CIRCUITBREAKER WITH 6mA TRIP.KE-50 MICROWAVE OVEN120V 1P 2WKITCHEN: 2 KVA20/1 16.67 3/4"C,2#12,#12G HARDWIRED NEMA 5-20RN/ADIV 26 L1KA-9 PROVIDE GFCI CIRCUITBREAKER WITH 6mA TRIP.KE-56 FROST TOP120V 1P 2WKITCHEN: 1.51 KVA 20/1 12.6 3/4"C,2#12,#12G HARDWIRED NEMA 5-20R, GFCIN/ADIV 26 L1KA-16KE-60 POP-UP TOASTER208/120V 2P 3W KITCHEN: 2.6 KVA 15/2 12.5 3/4"C,3#12,#12G HARDWIRED NEMA 6-15RN/ADIV 26 L1KA-20,22 PROVIDE GFCI CIRCUITBREAKER WITH 6mA TRIP.KE-61A INDUCTION WARMER 120V 1P 2WKITCHEN: 0.65 KVA 20/1 5.42 3/4"C,2#12,#12G RECEPTACLE NEMA 5-20RN/ADIV 26 L1KA-21 PROVIDE GFCI CIRCUITBREAKER WITH 6mA TRIP.KE-61B INDUCTION WARMER 120V 1P 2WKITCHEN: 0.65 KVA 20/1 5.42 3/4"C,2#12,#12G RECEPTACLE NEMA 5-20RN/ADIV 26 L1KA-23 PROVIDE GFCI CIRCUITBREAKER WITH 6mA TRIP.KE-61C INDUCTION WARMER 120V 1P 2WKITCHEN: 0.65 KVA 20/1 5.42 3/4"C,2#12,#12G RECEPTACLE NEMA 5-20RN/ADIV 26 L1KA-25 PROVIDE GFCI CIRCUITBREAKER WITH 6mA TRIP.KE-61D INDUCTION WARMER 120V 1P 2WKITCHEN: 0.65 KVA 20/1 5.42 3/4"C,2#12,#12G RECEPTACLE NEMA 5-20RN/ADIV 26 L1KA-27 PROVIDE GFCI CIRCUITBREAKER WITH 6mA TRIP.KE-84 OPEN DISPLAYERMERCHANDISER120V 1P 2WKITCHEN: 1.92 KVA 20/1 16 3/4"C,2#12,#12G RECEPTACLE NEMA 5-20RN/ADIV 26 L1KA-35 PROVIDE GFCI CIRCUITBREAKER WITH 6mA TRIP.KE-85 OPEN DISPLAYERMERCHANDISER208/120V 2P 3W KITCHEN: 1.99 KVA 20/2 9.55 3/4"C,3#12,#12G RECEPTACLE NEMA 6-20RN/ADIV 26 L1KA-31,33 PROVIDE GFCI CIRCUITBREAKER WITH 6mA TRIP.KE-89 REACH-IN FREEZER120V 1P 2WKITCHEN: 1.14 KVA 20/1 9.5 3/4"C,2#12,#12G RECEPTACLE NEMA 5-20RN/ADIV 26 L1KA-29 PROVIDE GFCI CIRCUITBREAKER WITH 6mA TRIP.KE-96A GAS GRILL120V 1P 2WKITCHEN: 0.1 KVA 20/1 0.83 3/4"C,2#12,#12G HARDWIRED LOCKABLE CIRCUITBREAKERN/ADIV 26 LPAT-1 PROVIDE CONNECTION FORGAS IGNITER CIRCUIT. VERIFYREQUIREMENTS WITH GRILLPROVIDER.KE-96B GAS GRILL120V 1P 2WKITCHEN: 0.1 KVA 20/1 0.83 3/4"C,2#12,#12G HARDWIRED LOCKABLE CIRCUITBREAKERN/ADIV 26 LPAT-3 PROVIDE CONNECTION FORGAS IGNITER CIRCUIT. VERIFYREQUIREMENTS WITH GRILLPROVIDER.KE-98 HANDWASHING SYSTEM 120V 1P 2WKITCHEN: 0.74 KVA 20/1 6.2 3/4"C,2#12,#12G RECEPTACLE NEMA 5-20R, GFCIN/ADIV 26 LPAT-5POOL EQUIPMENT SCHEDULECALLOUT EQUIPMENT DESCRIPTION VOLTAGELOAD TYPEOCP AMPS CONDUIT & WIRE CONNECTIONTYPEDISCONNECTDESCRIPTIONDISC NEMARATINGDISC BY CIRCUITNOTESPEQ-1 POOL RECIRCULATIONPUMP120V 1P 2WMOTOR: 1.92 KVA20/1 16 3/4"C,2#12,#12G HARDWIRED MOTORRATEDTOGGLESWITCHNEMA 4X DIV 26 L1P-1PEQ-2 SPLASH PADRECIRCULATION PUMP120V 1P 2WMOTOR: 1.92 KVA20/1 16 3/4"C,2#12,#12G HARDWIRED MOTORRATEDTOGGLESWITCHNEMA 4X DIV 26 L1P-3PEQ-3 SPLASH PAD FEATUREPUMP120V 1P 2WMOTOR: 1.92 KVA20/1 16 3/4"C,2#12,#12G HARDWIRED MOTORRATEDTOGGLESWITCHNEMA 4X DIV 26 L1P-5PEQ-6 POOL CHEMICALCONTROLLER120V 1P 2WNONCONTINUOUS: 0.4 KVA 20/1 3.3 3/4"C,2#12,#12GGFCIRECEPTACLENEMA 5-20RN/ADIV 26 L1P-7PEQ-7 SPLASH PAD CHEMICALCONTROLLER120V 1P 2WNONCONTINUOUS: 0.4 KVA 20/1 3.3 3/4"C,2#12,#12GGFCIRECEPTACLENEMA 5-20RN/ADIV 26 L1P-9PEQ-8.1 POOL LIGHTS120V 1P 2WNONCONTINUOUS: 0.24 KVA 20/1 2 3/4"C,2#12,#12G HARDWIRED LOCKABLECIRCUITBREAKERN/ADIV 26 L1P-4 PROVIDE LOCKABLE CIRCUITBREAKERPEQ-8.2 POOL LIGHTS120V 1P 2WNONCONTINUOUS: 0.24 KVA 20/1 2 3/4"C,2#12,#12G HARDWIRED LOCKABLECIRCUITBREAKERN/ADIV 26 L1P-4 PROVIDE LOCKABLE CIRCUITBREAKERPEQ-9 POOL AUTOFILL120V 1P 2WNONCONTINUOUS: 0.06 KVA 20/1 0.5 3/4"C,2#12,#12GGFCIRECEPTACLENEMA 5-20RN/ADIV 26 L1P-6PEQ-10 SPLASH PAD AUTOFILL 120V 1P 2WNONCONTINUOUS: 0.06 KVA 20/1 0.5 3/4"C,2#12,#12GGFCIRECEPTACLENEMA 5-20RN/ADIV 26 L1P-6PEQ-11 POOL HEATER120V 1P 2WNONCONTINUOUS: 0.6 KVA 20/1 5 3/4"C,2#12,#12G HARDWIRED LOCKABLECIRCUITBREAKERN/ADIV 26 L1P-8 PROVIDE LOCKABLE CIRCUITBREAKERPEQ-12 SPLASH PAD HEATER 120V 1P 2WNONCONTINUOUS: 0.6 KVA 20/1 5 3/4"C,2#12,#12G HARDWIRED LOCKABLECIRCUITBREAKERN/ADIV 26 L1P-10 PROVIDE LOCKABLE CIRCUITBREAKEREV CHARGING EQUIPMENT SCHEDULECALLOUT EQUIPMENT DESCRIPTION VOLTAGELOAD TYPEOCP AMPS CONDUIT & WIRE CONNECTIONTYPEDISCONNECTDESCRIPTIONDISC NEMARATINGDISC BY CIRCUITNOTESEV-1 EV CHARGING PEDESTAL 208V 2P 2WCONTINUOUS: 6.66 KVA40/2 32 3/4"C,2#8,#10G HARDWIRED LOCKABLECIRCUITBREAKERN/ADIV 26 EV-1,3 PROVIDE DUAL EV CHARGINGPEDESTAL WITH (2) 40A, SAEJ1772 STANDARD PLUG. BASISOF DESIGN: CHARGEPOINTCT4021-GW1.EV-2 EV CHARGING PEDESTAL 208V 2P 2WCONTINUOUS: 6.66 KVA40/2 32 3/4"C,2#8,#10G HARDWIRED LOCKABLECIRCUITBREAKERN/ADIV 26 EV-5,7 CIRCUIT SHOWN FOR SECONDPLUG ON DUAL CHARGINGPEDESTAL. SEE SITE PLAN FORLOCATION.LAUNDRY EQUIPMENT SCHEDULECALLOUT EQUIPMENT DESCRIPTION VOLTAGELOAD TYPEOCP AMPS CONDUIT & WIRE CONNECTIONTYPEDISCONNECTDESCRIPTIONDISC NEMARATINGDISC BY CIRCUITNOTESDRY-1.1 GUEST LAUNDRY DRYER 208/120V 2P 3W NONCONTINUOUS: 4.75 KVA 30/2 22.84 3/4"C,3#10,#10G RECEPTACLE NEMA 14-30R N/ADIV 26 L11-20,22 VERIFY PLUG TYPE WITHEQUIPMENT PROVIDER PRIORTO ROUGH-IN.DRY-1.2 GUEST LAUNDRY DRYER 208/120V 2P 3W NONCONTINUOUS: 4.75 KVA 30/2 22.84 3/4"C,3#10,#10G RECEPTACLE NEMA 14-30R N/ADIV 26 L11-24,26 VERIFY PLUG TYPE WITHEQUIPMENT PROVIDER PRIORTO ROUGH-IN.DRY-1.3 GUEST LAUNDRY DRYER 208/120V 2P 3W NONCONTINUOUS: 4.75 KVA 30/2 22.84 3/4"C,3#10,#10G RECEPTACLE NEMA 14-30R N/ADIV 26 L11-28,30 VERIFY PLUG TYPE WITHEQUIPMENT PROVIDER PRIORTO ROUGH-IN.DRY-1.4 GUEST LAUNDRY DRYER 208/120V 2P 3W NONCONTINUOUS: 4.75 KVA 30/2 22.84 3/4"C,3#10,#10G RECEPTACLE NEMA 14-30R N/ADIV 26 L11-32,34 VERIFY PLUG TYPE WITHEQUIPMENT PROVIDER PRIORTO ROUGH-IN.DRY-2.1 COMMERCIAL DRYER 208V 3P 4WNONCONTINUOUS: 4.32 KVA 15/3 12 3/4"C,4#12,#12G HARDWIRED3P30A, 15AFUSESNEMA 1 DIV 26 L11-2,4,6 VERIFY EXACT CONNECTIONLOCATIONS ANDREQUIREMENTS WITHEQUIPMENT PROVIDER.DRY-2.2 COMMERCIAL DRYER 208V 3P 4WNONCONTINUOUS: 4.32 KVA 15/3 12 3/4"C,4#12,#12G HARDWIRED3P30A, 15AFUSESNEMA 1 DIV 26 L11-8,10,12 VERIFY EXACT CONNECTIONLOCATIONS ANDREQUIREMENTS WITHEQUIPMENT PROVIDER.DRY-2.3 COMMERCIAL DRYER 208V 3P 4WNONCONTINUOUS: 4.32 KVA 15/3 12 3/4"C,4#12,#12G HARDWIRED3P30A, 15AFUSESNEMA 1 DIV 26 L11-14,16,18 VERIFY EXACT CONNECTIONLOCATIONS ANDREQUIREMENTS WITHEQUIPMENT PROVIDER.WASH-1.1 GUEST LAUNDRY DRYER 120V 1P 2WNONCONTINUOUS: 1.8 KVA 20/1 15 3/4"C,2#10,#10G RECEPTACLE NEMA 5-20RN/ADIV 26 L11-19WASH-1.2 GUEST LAUNDRY DRYER 120V 1P 2WNONCONTINUOUS: 1.8 KVA 20/1 15 3/4"C,2#10,#10G RECEPTACLE NEMA 5-20RN/ADIV 26 L11-21WASH-1.3 GUEST LAUNDRY DRYER 120V 1P 2WNONCONTINUOUS: 1.8 KVA 20/1 15 3/4"C,2#10,#10G RECEPTACLE NEMA 5-20RN/ADIV 26 L11-23WASH-1.4 GUEST LAUNDRY DRYER 120V 1P 2WNONCONTINUOUS: 1.8 KVA 20/1 15 3/4"C,2#10,#10G RECEPTACLE NEMA 5-20RN/ADIV 26 L11-25WASH-2.1 COMMERCIAL WASHER 208V 3P 4WNONCONTINUOUS: 3.6 KVA 15/3 10 3/4"C,4#12,#12G HARDWIRED3P30A, 15AFUSESNEMA 1 DIV 26 L11-1,3,5 VERIFY EXACT CONNECTIONLOCATIONS ANDREQUIREMENTS WITHEQUIPMENT PROVIDER.WASH-2.2 COMMERCIAL WASHER 208V 3P 4WNONCONTINUOUS: 3.6 KVA 15/3 10 3/4"C,4#12,#12G HARDWIRED3P30A, 15AFUSESNEMA 1 DIV 26 L11-7,9,11 VERIFY EXACT CONNECTIONLOCATIONS ANDREQUIREMENTS WITHEQUIPMENT PROVIDER.WASH-2.3 COMMERCIAL WASHER 208V 3P 4WNONCONTINUOUS: 3.6 KVA 15/3 10 3/4"C,4#12,#12G HARDWIRED3P30A, 15AFUSESNEMA 1 DIV 26 L11-13,15,17 VERIFY EXACT CONNECTIONLOCATIONS ANDREQUIREMENTS WITHEQUIPMENT PROVIDER.32 MERCHANT STREET, SUITE 208HONOLULU, HI 96813808-352-5299OWNER:HOMEWOOD SUITES by HILTON SPOKANE VALLEY, WA 13515 E. Carlisle Avenue Spokane Valley, WA 99216FSC PROJECT NO. 21012PERMITDOCUMENTSMay 31, 2024GL8 MirabeauPoint, LLCTMK:PID: 45101.0401 10909 E. Pierce LaneSpokane, WA 99206(509) 919-0901Revision ScheduleNumber Description Date5915 S REGAL STREETSUITE 201SPOKANE, WA 99223PH: 509.473.9218Kelly@kwrllc.comwww.kwrllc.com5/30/2024 12:49:01 PMSTATE OF WASHINGTONREGISTERED PROFESSIONAL ENG INEER48350 KELLY A N DREW WATERMAN05.31.24EQUIPMENTSCHEDULESE-003 LUMINAIRE SCHEDULETYPESYMBOLMFGR & CATALOG NUMBERDRIVERMOUNTING LIGHTSOURCELUMENOUTPUTINPUTWATTSLUMENS/WATTNOTESB06ALPHABET#NU6RD SW 20LM 30K 90 HE70 WH WH NC UNV DIM10120-277V, 0-10VDIMMINGRECESSED LED, 3000K 1660 LM 17W 98 6" RECESSED DOWNLIGHTB06EALPHABET#NU6RD SW 20LM 30K 90 HE70 WH WH NC UNV DIM10EM10CA20120-277V, 0-10VDIMMINGRECESSED LED, 3000K 1660 LM 17W 98 6" RECESSED DOWNLIGHT, EMERGENCY. PROVIDE UL924 BATTERY PACK.WHERE LOCATED IN INACCESSIBLE CEILING SPACE, MOUNT IN NEARESTACCESSIBLE CEILING OR NON-PUBLIC UTILITY SPACE WITHIN 50'.B20AALPHABET#NU4QA 15LM 30K 90 35D DS WH WH NC UNV DIM10120-277V, 0-10VDIMMINGRECESSED LED, 3000K 1280 LM 13W 98 SQUARE LED DOWNLIGHT, ADJUSTABLE.B21ALPHABET#NU4QD SW 25LM 40K 90 HE70 WH WH NC UNV DIM10120-277V, 0-10VDIMMINGRECESSED LED, 4000K 2000 LM 20W 100 SQUARE LED DOWNLIGHT, EXTERIOR. WET LOCATION RATED.B21EALPHABET#NU4QD SW 25LM 40K 90 HE70 WH WH NC UNV DIM10EM10CA20120-277V, 0-10VDIMMINGRECESSED LED, 4000K 2000 LM 20W 100 SQUARE LED DOWNLIGHT, EXTERIOR, EMERGENCY. WET LOCATIONRATED. PROVIDE UL924 BATTERY PACK. WHERE LOCATED ININACCESSIBLE CEILING SPACE, MOUNT IN NEAREST ACCESSIBLE CEILINGOR NON-PUBLIC UTILITY SPACE WITHIN 50'.B22ALPHABET#NU4QD SW 25LM 40K 90 HE70 WH WH NC UNV DIM10120-277V, 0-10VDIMMINGRECESSED LED, 4000K 2000 LM 20W 98 SQUARE LED DOWNLIGHT, RESTROOMSB22AALPHABET#NU4QA 15LM 40K 90 35D DS WH WH NC UNV DIM10120-277V, 0-10VDIMMINGRECESSED LED, 4000K 1200 LM 14W 85 SQUARE LED DOWNLIGHT, ADJUSTABLE, RESTROOMSB22AEALPHABET#NU4QA 15LM 40K 90 35D DS WH WH NC UNV DIM10EM10CA20120-277V, 0-10VDIMMINGRECESSED LED, 4000K 1200 LM 14W 85 SQUARE LED DOWNLIGHT, ADJUSTABLE, EMERGENCY. PROVIDE UL924BATTERY PACK. WHERE LOCATED IN INACCESSIBLE CEILING SPACE,MOUNT IN NEAREST ACCESSIBLE CEILING OR NON-PUBLIC UTILITY SPACEWITHIN 50'.B22EALPHABET#NU4QD SW 25LM 40K 90 HE70 WH WH NC UNV DIM10EM10CA20120-277V, 0-10VDIMMINGRECESSED LED, 4000K 2000 LM 20W 100 SQUARE LED DOWNLIGHT, RESTROOMS, EMERGENCY. PROVIDE UL924BATTERY PACK. WHERE LOCATED IN INACCESSIBLE CEILING SPACE,MOUNT IN NEAREST ACCESSIBLE CEILING OR NON-PUBLIC UTILITY SPACEWITHIN 50'.B25ALPHABET#NU4QW 10LM 30K 90 WW WH WH NC UNV120-277V, 0-10VDIMMINGRECESSED LED, 3000K 840 LM 9W 93 SQUARE LED DOWNLIGHT, WALL WASH OPTIC. ORIENT OPTIC ASINDICATED BY CHEVRONS ON LIGHTING PLANS.B26ALPHABET#NU4QW 10LM 40K 90 WW WH WH NC UNV120-277V, 0-10VDIMMINGRECESSED LED, 4000K 840 LM 9W 93 SQUARE LED DOWNLIGHT, WALL WASH OPTIC, RESTROOMS. ORIENT OPTICAS INDICATED BY CHEVRONS ON LIGHTING PLANS.C48LITHONIA#CLX L48 4000LM SEF FDL MVOLT GZ10 40K 80CRI WH120-277V, 0-10VDIMMINGSURFACE LED, 4000K 4000LM 26W 153 4' LED STRIPLIGHTC48ELITHONIA#CLX L48 4000LM SEF FDL MVOLT GZ10 40K 80CRIE10WLCP WH120-277V, 0-10VDIMMINGSURFACE LED, 4000K 4000 LM 26W 153 4' LED STRIPLIGHT, EMERGENCY. PROVIDE INTEGRAL UL924 BATTERYPACK.C96LITHONIA#CLX L96 8000LM SEF FDL MVOLT GZ10 40K 80CRI WH120-277V, 0-10VDIMMINGSURFACE LED, 4000K 8000 LM 51W 156 8' LED STRIPLIGHTC96ELITHONIA#CLX L96 8000LM SEF FDL MVOLT GZ10 40K 80CRIE10WLCP WH120-277V, 0-10VDIMMINGSURFACE LED, 4000K 8000 LM 51W 156 8' LED STRIPLIGHT, EMERGENCY. PROVIDE INTEGRAL UL924 BATTERYPACK.D04AXIS#SCDI 300 500 80 30 BW FL 4' AP UNV DP 1120-277V, 0-10VDIMMINGSIDE MOUNTTO ADJACENTTRELLISBEAM, LENSFLUSH WITHBEAMLED, 3000K 1200LM UP /2000LM DN31W 105 4' LINEAR DIRECT/INDIRECT, LOBBY TRELLIS. LUMINAIRE SHALL BE SIDEMOUNTED TO SIDE OF TRELLIS BEAM, LENS FLUSH WITH BOTTOM.G01ELITHONIA#FEM L48 4000LM LPACL WD MVOLT GZ10 40K 80CRIFEMSMB E10WMCP120-277V, 0-10VDIMMINGSURFACE LED, 4000K 4066 LM 24W 169 48" LED ELEVATOR PIT LIGHT. STRIP LIGHT WITH CLEAR LENS AND NEMA4X HOUSING AND WET LOCATION FITTING(S). PROVIDE UL924 EMERGENCYBATTERY PACK. COORDINATE FINAL FIXTURE MOUNTING WITH ELEVATORINSTALLER PRIOR TO ROUGH-IN. PROVIDE SUFRACE MOUNTINGBRACKETS.G02ELITHONIA#FEM L48 6000LM LPACL MD MVOLT GZ10 40K 80CRIFEMSMB E10WMCP120-277V, 0-10VDIMMINGSURFACE LED, 4000K 6061 LM 38W 159 48" LED ELEVATOR PIT LIGHT. STRIP LIGHT WITH CLEAR LENS AND NEMA4X HOUSING AND WET LOCATION FITTING(S). PROVIDE UL924 EMERGENCYBATTERY PACK. COORDINATE FINAL FIXTURE MOUNTING WITH ELEVATORINSTALLER PRIOR TO ROUGH-IN. PROVIDE SUFRACE MOUNTINGBRACKETS.L06AXIS#EX2R 750 80 40 SO 6 W UNV DP 1 DF120-277V, 0-10VDIMMINGRECESSED LED, 4000K 4500LM 43W 104 6' RECESSED LINEAR, WET LOCATION RATED.L06AAXIS#EX2R 750 80 40 WW 6 W UNV DP 1 DF120-277V, 0-10VDIMMINGRECESSED LED, 4000K 4500LM 43W 104 6' RECESSED LINEAR, WET LOCATION RATED, WALLWASH. ORIENTATIONAS INDICATED BY CHEVRON ON PLANS.L07FLUXWERX#NT1 L D1 B D 30 F2 M 6'120-277V, 0-10VDIMMINGRECESSED LED, 3000K 5400LM 57W 95 2" APERTURE 6' RECESSED LINEAR, REGRESSED LENS.L07EFLUXWERX#NT1 L D1 B D 30 F2 M 6' B(1)120-277V, 0-10VDIMMINGRECESSED LED, 3000K 5400LM 57W 95 2" APERTURE 6' RECESSED LINEAR, REGRESSED LENS, EMERGENCY.PROVIDE INTEGRAL UL924 BATTERY PACK.L12AXIS#EX2R 750 80 40 SO 12 W UNV DP 1 DF120-277V, 0-10VDIMMINGRECESSED LED, 4000K 9000LM 89W 101 12' RECESSED LINEAR, WET LOCATION RATED.L12EAXIS#EX2R 750 80 40 SO 12 W UNV DP 1 DF B(1)120-277V, 0-10VDIMMINGRECESSED LED, 4000K 9000LM 89W 101 12' RECESSED LINEAR, WET LOCATION RATED, EMERGENCY. PROVIDEINTEGRAL UL924 BATTERY PACK.L16AXIS#EX2WD 500 80 40 SO S(16) B UNV DP 1120-277V, 0-10VDIMMINGSIDE MOUNTTO ADJACENTTRELLISBEAM, LENSFLUSH WITHBEAMLED, 4000K 8000LM 79W 101 16' LINEAR, PATIO TRELLIS, SIDE MOUNTED TO ADJACENT BEAM, LENSFLUSH WITH BOTTOM OF BEAMS.P02REMINGTON LIGHTING#STYLE 15309120V, ELVDIMMINGPENDANT (8) E26 LEDREPLACEMENT,3000KTBD80WMAX(10WLAMPS)TBD LOBBY DECORATIVE PENDANT CLUSTERP03REMINGTON LIGHTING#STYLE 15310120V, ELVDIMMINGPENDANT,+64"(1) E26 LEDREPLACEMENT,4000KTBD 15WMAXTBD PUBLIC RESTROOM DECORATIVE PENDANTP04REMINGTON LIGHTING#STYLE 15307120V, ELVDIMMINGPENDANT,+64"(1) E26 LEDREPLACEMENT,3000KTBD 15WMAXTBD RECEPTION DECORATIVE PENDANTP05ARKANSAS LIGHTING#ITEM 4400P120V, ELVDIMMINGPENDANT,+6'-9"(1) E26 LEDREPLACEMENT,4000KTBD 15WMAXTBD OUTDOOR KITCHEN ISLAND PENDANTP06ALW#CRT3/WL 13 83 40 80 DF 07 83 40 80 DF D V10 1C SB120V, ELVDIMMINGPENDANT,+9'-0"LED, 4000K 1196LM UP /648LM DN21W 88 OUTDOOR DIRECT/INDIRECT CYLINDER PENDANT. PROVIDE NEMA 4XJUNCTION BOX ABOVE TRELLIS FOR BRANCH CIRCUITING, WITH CONDUITNIPPLE BETWEEN BEAMS TO CANOPY MOUNTED BELOW. FIELDCOORDINATE EXACT MOUNTING REQUIREMENTS.R01-11AXIS#B2SQRLED 300 80 40 WW S(11'4") W UNV DP 1 DF120-277V, 0-10VDIMMINGRECESSED LED, 4000K 3300 LM 31W 107 RECESSED LINEAR WALL WASH, RESTROOMS. WALL TO WALLINSTALLATION. VERIFY EXACT LENGTH PRIOR TO ORDERING.R08AXIS#WBRLED 750 80 40 S 8 W UNV DP 1 D +N120-277V, 0-10VDIMMINGRECESSED LED, 4000K 6000 LM 70W 87 8' RECESSED LINEAR RECESSED WET BEAM. PROVIDE WITH NATATORIUMOPTION.R08EAXIS#WBRLED 750 80 40 S 8 W UNV DP 1 D B1 +N120-277V, 0-10VDIMMINGRECESSED LED, 4000K 8000 LM 70W 87 8' RECESSED LINEAR RECESSED WET BEAM. PROVIDE WITH NATATORIUMOPTION. PROVIDE INTEGRAL UL924 BATTERY PACK.R21LITHONIA#EPANL 2X2 4000LM 80CRI 40K MIN10 ZT MVOLT120-277V, 0-10VDIMMINGRECESSED LED, 4000K 4121 LM 37W 111 2X2 LED TROFFER, BACK OF HOUSE, HIGH OUTPUTR21ELITHONIA#EPANL 2X2 4000LM 80CRI 40K MIN10 ZT MVOLT E10WCP120-277V, 0-10VDIMMINGRECESSED LED, 4000K 4121 LM 37W 111 2X2 LED TROFFER, BACK OF HOUSE, HIGH OUTPUT, EMERGENCY. PROVIDEINTEGRAL UL924 BATTERY PACK.R22MARK ARCHITECTURAL LIGHTING#WHSPR 2X2 80CRI 40K 3000LM MIN10 MVOLT SWC120-277V, 0-10VDIMMINGRECESSED LED, 4000K 2969 LM 24W 125 2X2 LED TROFFER, FRONT OF HOUSER24MARK ARCHITECTURAL LIGHTING#WHSPR 2X4 80CRI 40K 3000LM MIN10 MVOLT SWC120-277V, 0-10VDIMMINGRECESSED LED, 4000K 3014 LM 21W 143 2X4 LED TROFFER, FRONT OF HOUSER25LITHONIA#EPANL 2X4 4000LM 80CRI 40K MIN10 ZT MVOLT120-277V, 0-10VDIMMINGRECESSED LED, 4000K 3963 LM 37W 107 2X4 LED TROFFER, BACK OF HOUSER25ELITHONIA#EPANL 2X4 4000LM 80CRI 40K MIN10 ZT MVOLT E10WCP120-277V, 0-10VDIMMINGRECESSED LED, 4000K 3963 LM 37W 107 2X4 LED TROFFER, BACK OF HOUSE, EMERGENCY. PROVIDE INTEGRALUL924 BATTERY PACK.R26MARK ARCHITECTURAL LIGHTING#WHSPR 2X4 80CRI 30K 3000LM MIN10 MVOLT SWC120-277V, 0-10VDIMMINGRECESSED LED, 3000K 3014 LM 21W 143 2X4 LED TROFFER, MEETING ROOMR27MARK ARCHITECTURAL LIGHTING#WHSPR 2X4 80CRI 40K 3000LM MIN10 MVOLT SWC DGA24120-277V, 0-10VDIMMINGRECESSED LED, 4000K 3014 LM 21W 143 2X4 LED TROFFER, FRONT OF HOUSE, GWB CEILINGLUMINAIRE SCHEDULE (CONT.)TYPESYMBOLMFGR & CATALOG NUMBERDRIVERMOUNTING LIGHTSOURCELUMENOUTPUTINPUTWATTSLUMENS/WATTNOTESR44NULITE#BRT4 44 50 L30 UNV D WH120-277V, 0-10VDIMMINGRECESSED LED, 3000K 5000 LM 51W 78 4'X4' RECESSED INDIRECT TROFFERS02LITHONIAHEAD:#DSX1 LED P4 40K T2M MVOLT SPA NLTAIR2 PIRHN DBLXDPOLE:#SSS 22'-6" 4C DM19AS DBLXD120-277V, NLIGHTAIR DIMMINGPOLE, +25'-0"(22'-6" POLE,30" EXPOSEDBASE)LED, 4000K 15849 LM 124W 128 LED SITE POLE, TYPE II MEDIUM DISTRIBUTION. PROVIDE INTEGRALWIRELESS CONTROL MODULE FOR GROUPED DAYLIGHT / VACANCYRESPONSE.S03LITHONIAHEAD:#DSX1 LED P4 40K T3M MVOLT SPA NLTAIR2 PIRHN DBLXDPOLE:#SSS 22'-6" 4C DM19AS DBLXD120-277V, NLIGHTAIR DIMMINGPOLE, +25'-0"(22'-6" POLE,30" EXPOSEDBASE)LED, 4000K 16032 LM 124W 129 LED SITE POLE, TYPE III MEDIUM DISTRIBUTION. PROVIDE INTEGRALWIRELESS CONTROL MODULE FOR GROUPED DAYLIGHT / VACANCYRESPONSE.S03-2LITHONIAHEAD:#DSX1 LED P4 40K T3M MVOLT SPA NLTAIR2 PIRHN DBLXDPOLE:#SSS 22'-6" 4C DM28AS DBLXD120-277V, NLIGHTAIR DIMMINGPOLE, +25'-0"(22'-6" POLE,30" EXPOSEDBASE)LED, 4000K 16032 LM 124W 129 LED SITE POLE, TYPE III MEDIUM DISTRIBUTION. PROVIDE INTEGRALWIRELESS CONTROL MODULE FOR GROUPED DAYLIGHT / VACANCYRESPONSE.S12LITHONIALUMINAIRE:#RADPT LED P2 40K ASY PT4 NLTAIR2 DBLXDPOLE:#RSS 12.5 RB PT DBLXD277V, 0-10VDIMMINGPOLE, +12'-6"(FLUSH BASE)LED, 4000K 4898 LM 38W 128 LED POST TOP LIGHT - PET AREAS21LITHONIA#KBA8 LED 12C 530 40K ASY MVOLT DBLXD120-277VBOLLARD,CONCRETEBASELED, 4000K 1741LM 22W 79 LED BOLLARD. ASYMMETRIC DISTRIBUTION SHALL BE ORIENTED TOWARDPATHWAYS/HARDSCAPE AS INDICATED.SZ01KLUS#KWP-CR40-1220-24EXTRUSION: KLUS #LIPOD-50LENS: LIGER-45POWER SUPPLY EXTRUSION,FIREPLACENOTCHLED, 4000K 223LM/FT 2.9W/FT 76 EXTERIOR ACCENT LIGHT, FIREPIT. WET LOCATION RATED. PROVIDELENGTHS AS SHOWN ON PLANS. SEE ARCHITECTURAL SHEET A-406 FORMOUNTING DETAILS. COORDINATE WITH FIREPLACE FABRICATOR FORFIXTURE AND POWER SUPPLY MOUNTING.SZ02KLUS#KWP-CR40-1220-24EXTRUSION: KLUS #LIPOD-50LENS: LIGER-45POWER SUPPLY EXTRUSION,SURFACEUNDERBACKSPLASHLED, 4000K 223LM/FT 2.9W/FT 76 EXTERIOR ACCENT LIGHT, BARBEQUE / SINK BACKSPLASH. WET LOCATIONRATED. PROVIDE LENGTHS AS SHOWN ON PLANS. SEE ARCHITECTURALSHEET A-406 FOR MOUNTING DETAILS. COORDINATE WITH CASEWORKFABRICATOR FOR FIXTURE AND POWER SUPPLY MOUNTING.SZ03KLUS#KWP-CR40-1220-24EXTRUSION: KLUS #LIPOD-50LENS: LIGER-45POWER SUPPLY EXTRUSION,SURFACEUNDERBACKSPLASHLED, 4000K 223LM/FT 2.9W/FT 76 EXTERIOR ACCENT LIGHT, EXTERIOR KITCHEN ISLAND UNDERCOUNTER.WET LOCATION RATED. PROVIDE LENGTHS AS SHOWN ON PLANS. SEEARCHITECTURAL SHEET A-406 FOR MOUNTING DETAILS. COORDINATEWITH CASEWORK FABRICATOR FOR FIXTURE AND POWER SUPPLYMOUNTING.W01REMINGTON LIGHTING#STYLE 15311.01120V, ELVDIMMINGWALL, +6'-0" (1) E26 LEDREPLACEMENT,3000KN/A 15WMAXN/A CORRIDOR DECORATIVE WALL SCONCEW02ALW#CRU3/WL 07 83 40 40 FT 13 83 40 40 N V10 1C SG120-277VWALLLED, 4000K 1839 LM 18W 108 EXTERIOR COURTYARD DECORATIVE WALL SCONCE, DIRECT/INDIRECTW02EALW#CRU3/WL 07 83 40 40 FT 13 83 40 40 R V10 1C SG EMB120-277VWALLLED, 4000K 1839 LM 18W 108 EXTERIOR COURTYARD DECORATIVE WALL SCONCE, DIRECT/INDIRECT,EMERGENCY. PROVIDE REMOTE MOUNTED UL924 BATTERY, MOUNTED INNEAREST ACCESSIBLE CEILING SPACE.W03ALW#CRU3/WL 13 83 40 40 FT 13 83 40 40 N V10 1C SB120-277VWALLLED, 4000K 2392 LM 24W 102 EXTERIOR DECORATIVE WALL SCONCE, DIRECT/INDIRECTW03EALW#CRU3/WL 13 83 40 40 FT 13 83 40 40 R V10 1C SB EMB120-277VWALLLED, 4000K 2392 LM 24W 102 EXTERIOR DECORATIVE WALL SCONCE, DIRECT/INDIRECT, EMERGENCY.REMOTE UL924 BATTERY PACK, FIELD COORDINATE BATTERY MOUNTINGLOCATION IN NEAREST INTERIOR ACCESSIBLE CEILING SPACE.W04SPI LIGHTING#EEW12280 L46W PT51 120-277V 4000K 80 IND NAT120-277V, 0-10VDIMMINGWALL, +10'-0"AFFLED, 4000K 5980 LM 46W 130 WALL MOUNTED INDIRECT LUMENAIRE FOR INDOOR POOL. PROVIDE WITHNATATORIUM OPTION. FIELD ADJUST TO FORWARD DISTRIBUTION OF 35DEGREES.W06WAC LIGHTING#3611-30-BK12V, VIA POWERSUPPLYWALL, +6'-0"AFFLED, 4000K 325LM UP /325LM DN7.5W 86 DECORATIVE DIRECT/INDIRECT WALL SCONCE, COLUMN RECESSEDNOTCHES. POWERED VIA REMOTE MOUNTED 12V POWER SUPPLY. FIELDCOORDINATE MOUNTING REQUIREMENTS ON DECORATIVE FACADE OFCOLUMN. CCT SHALL BE SET TO 4000K.W24LITHONIA#FMVCSLS 24IN MVOLT 30K35K40K 90CRI BN120-277VWALL, +6"ABOVEVANITYMIRRORLED, 3000K 1740 LM 18W 96 24" LED VANITY. FIELD SELECT 3000K COLOR TEMPERATURE.W48EAXIS#TB2WDLED 750 80 40 ASO 4 AP UNV DP 1 B(1)120-277V, 0-10VDIMMINGWALL, +8'-6" LED, 4000K 3000 LM 30W 100 4' STAIRWELL LED, EMERGENCY. PROVIDE UL924 EMERGENCY BATTERYPACK.X01LITHONIA#LQM S W 3 G 120/277 EL N SDELECTRONIC UNIVERSAL LED, GREEN N/A 1W N/A LED EXIT LIGHT (SINGLE FACE). CHEVRONS AS INDICATED BY ARROWS ONPLANS.X02LITHONIA#LQM S W 3 G 120/277 EL N SDELECTRONIC UNIVERSAL LED, GREEN N/A 2W N/A LED EXIT LIGHT (DOUBLE FACE). CHEVRONS AS INDICATED BY ARROWSON PLANS.X03LITHONIA#LQM S W 3 G 120/277 EL N SDELECTRONIC WALL, +12" LED, GREEN N/A 1W N/A LED EXIT LIGHT (SINGLE FACE, LOW MOUNT). MOUNT AT +12" FROM FLOOR,WITHIN 4" OF LATCH SIDE OF DOOR.X04Isolite#HZE EM G MB SDELECTRONIC UNIVERSAL LED, GREEN N/A 1W N/A LED EXIT LIGHT FOR WET LOCATIONS.Z01KLUS#K CR30 1220 24EXTRUSION: KLUS#45-ALULENS: HSPOWER SUPPLY,0-10V DIMMINGEXTRUSION INCOVELED, 3000K 215LM/FT 2.9W/FT 74 ACCENT LIGHT, LOBBY COVE, ORIENTED OUT FROM COVE. PROVIDELENGTHS AS SHOWN ON DRAWINGS SEE ARCHITECTURAL SHEET A-608FOR DETAILS. MOUNT POWER SUPPLY ABOVE NEAREST ACCESSIBLECEILING.Z02KLUS#K CR30 1220 24EXTRUSION: KLUS#KOPRO-30LENS: HSPOWER SUPPLY,0-10V DIMMINGEXTRUSION INCOVELED, 3000K 215LM/FT 2.9W/FT 74 LINEAR COVE LIGHTING - DRAPERY POCKET. ORIENTED TOWARD WINDOW.PROVIDE LENGTHS AS SHOWN ON DRAWINGS. SEE ARCHITECTURALSHEET A-608 FOR DETAILS. MOUNT POWER SUPPLY ABOVE NEARESTACCESSIBLE CEILING.Z03AXIS#SCS 300 90 27 FL ## AP UNV DP 1 S120-277V, 0-10VDIMMINGSURFACE INARCHITECTURALPOCKETLED, 2700K 300LM/FT 3.25W/FT 93 LINEAR ACCENT LIGHT, OVER BARS. SURFACE MOUNT TO LAMINATECEILING. PROVIDE LENGTHS AS SHOWN ON DRAWINGS. SEEARCHITECTURAL SHEETS A-702 AND A-703 FOR ADDITIONAL INFORMATION.Z04KLUS#K CR27 1220 24EXTRUSION: KLUS#MICRO-PLUSLENS: HSPOWER SUPPLY,0-10V DIMMINGEXTRUSION INCHANNELUNDER SHELFLED, 2700K 215LM/FT 2.9W/FT 74 LINEAR ACCENT LIGHT, LOWER SHELF/BACKSPLASH AT BARS SEEARCHITECTURAL SHEETS A-702 AND A-703 FOR MOUNTING LOCATIONS.COORDINATE WITH CASEWORK PROVIDER FOR POWER SUPPLYMOUNTING.Z05KLUS#K CR27 1220 24EXTRUSION: KLUS#MICRO-PLUSLENS: HSPOWER SUPPLY,0-10V DIMMINGEXTRUSION INRECESSEDBANQUETTECAVITYLED, 2700K 215LM/FT 2.9W/FT 74 LED ACCENT UPLIGHT, MOUNTED IN BANQUETTE BENCH. PROVIDE LENGTHAS SHOWN ON PLANS. SEE ARCHITECTURAL SHEETS FOR MOUNTINGDETAILS. COORDINATE WITH BANQUETTE PROVIDER FOR POWER SUPPLYMOUNTING.32 MERCHANT STREET, SUITE 208HONOLULU, HI 96813808-352-5299OWNER:HOMEWOOD SUITES by HILTON SPOKANE VALLEY, WA 13515 E. Carlisle Avenue Spokane Valley, WA 99216FSC PROJECT NO. 21012PERMITDOCUMENTSMay 31, 2024GL8 MirabeauPoint, LLCTMK:PID: 45101.0401 10909 E. Pierce LaneSpokane, WA 99206(509) 919-0901Revision ScheduleNumber Description Date5915 S REGAL STREETSUITE 201SPOKANE, WA 99223PH: 509.473.9218Kelly@kwrllc.comwww.kwrllc.com5/30/2024 12:49:06 PMSTATE OF WASHINGTONREGISTERED PROFESSIONAL ENG INEER48350 KELLY A N DREW WATERMAN05.31.24LUMINAIRESCHEDULESE-004 DLLCM1BRDGGTWY12678LDM1LDMVOSPS1PS2RCMCONTROL DEVICE SCHEDULESYMBOLDESCRIPTIONPRODUCTNOTES / SOODAYLIGHT SENSORNLIGHT #NCM ADCXPROVIDE NETWORK LEVEL PHOTOCELL. PHOTOCELL TO CONTROL DAYLIGHT ZONES AS INDICATED BY LOWERCASE LETTERSBEGINNING WITH 'DZ'. IF NO ZONE LETTERS ARE INDICATED, THE DAYLIGHT SENSOR CONTROLS THE LIGHTS IN BOTH THEPRIMARY AND SECONDARY DAYLIGHT ZONES FOR WHICH THE SENSOR IS LOCATED. CONNECT DAYLIGHT SENSOR TO LOCALDIGITAL LIGHTING CONTROL NETWORK VIA CAT-5E NETWORK CABLE (PLENUM RATED).LIGHTING CONTROL MODULENLIGHT #NPP16(1) RELAYPROVIDE LIGHTING CONTROL MODULE TO CONTROL LIGHTING ZONES AS INDICATED. CONNECT MODULE TO LOCALDISTRIBUTED, DIGITAL LIGHTING CONTROL NETWORK VIA CAT-5E CABLING PER MANUFACTURER'S RECOMMENDATIONS.CONNECT LINE SIDE OF MODULE TO UNSWITCHED CIRCUIT, AND EXTEND LOAD SIDE SWITCHED CONDUCTORS TO LIGHTINGZONES AS INDICATED. NETWORK CABLE HOMERUNS SHALL TERMINATE AT NEAREST NETWORK BRIDGE.LIGHTING CONTROL NETWORK BRIDGENLIGHT #NBRG 88-PORT LIGHTING CONTROL NETWORK BRIDGEPROVIDE NETWORK BRIDGES AS REQUIRED TO ACCEPT CABLING HOMERUNS FROM LOCAL DISTRIBUTED LIGHTING CONTROLNETWORK HOMERUNS. PROVIDE BRIDGE POWER SUPPLY, NLIGHT PS150, TO SUPPLY BUS POWER WHERE A LIGHT DIMMINGMODULE/POWER PACK IS NOT PRESENT. PROVIDE BRIDGES AT REQUIRED TO CONNECT AREA TO ASSOCIATED GATEWAYHEAD END. ACTUAL QUANTITY AND LOCATION OF BRIDGES NOT SHOWN, AND SHALL BE PROVIDED IN MANUFACTURER SHOPDRAWINGS.LIGHTING CONTROL NETWORK GATEWAYNLIGHT SYSTEM CONTROLLER#NECY-24-BAC-ENC-GFXKNLIGHT GRAPHIC USER INTERFACE #NGWY2-GFXNLIGHT POWER SUPPLY #PS 150PROVIDE LIGHTING SYSTEM CONTROLLER AND GRAPHIC USER INTERFACE IN FACTORY NEMA 1 ENCLOSURE (NLIGHT#ENCNE1). PROVIDE POWER SUPPLY #PS 150. CONNECT GATEWAY TO BRIDGE HUB VIA CAT-5E CABLE. CONNECT GATEWAY TOLOCAL AREA NETWORK VIA CAT-5E CABLE. INTEGRAL ASTRONOMICAL TIME CLOCK FOR PROGRAMMABLE AUTOMATIC TIMEBASED CONTROL OF ALL NON-OCCUPANCY BASED CONTROL ZONES. COORDINATE TIME SCHEDULE FOR EACH INDIVIDUALZONE WITH OWNER DURING START-UP.DIGITAL LIGHTING CONTROL STATIONNLIGHT #NPODM DX1-POLE ON/OFF, RAISE/LOWER CONTROLSTATIONPROVIDE ON/OFF, RAISE/LOWER FOR CONTROLLED LIGHTING ZONE AS INDICATED ON THE DRAWINGS. LOWER CASE LETTERSDENOTE ZONES TO BE CONTROLLED. SWITCHES WITHOUT ZONE DESIGNATIONS CONTROL A SINGLE ZONE IN THE SPACE INWHICH THEY ARE INSTALLED.DIGITAL LIGHTING CONTROL STATIONNLIGHT #NPODM 2P DX2-POLE ON/OFF, RAISE/LOWER CONTROLSTATIONPROVIDE 2-POLE ON/OFF, RAISE/LOWER FOR CONTROLLED LIGHTING ZONE AS INDICATED ON THE DRAWINGS. LOWER CASELETTERS DENOTE ZONES TO BE CONTROLLED. CONNECT CONTROL STATION TO LOCAL LIGHTING CONTROL NETWORK BUSVIA CAT-5E CABLE.NETWORK LEVEL OCCUPANCY SENSORCONTROL STATION COMBINATION DEVICENLIGHT #NWSX LV DX1-POLE ON/OFF, OCCUPANCY SENSOR,RAISE/LOWER CONTROL STATIONPROVIDE NETWORK LEVEL DIGITAL WALL SWITCH OCCUPANCY SENSOR COMBINATION DEVICE WITH ON/OFF AND RAISELOWER BUTTONS FOR MANUAL CONTROL OF LIGHTING ZONES INDICATED. CONNECT CONTROL STATION / SENSOR DEVICE TOLOCAL LIGHTING CONTROL NETWORK DEVICES (I.E. LDM1) VIA CAT-5E NETWORK CABLE.KEYED DIGITAL LIGHTING CONTROL STATION NLIGHT #NPOD KEYPROVIDE 1-POLE ON/OFF KEYED CONTROL STATION FOR MANUAL OVERRIDE OF ZONE INDICATED. CONNECT CONTROLSTATION TO LOCAL LIGHTING CONTROL NETWORK BUS VIA CAT-5E CABLE.GRAPHIC LIGHTING CONTROL STATIONNLIGHT #NPOD GFX16-ZONE, 8-SCENE GRAPHIC LIGHTING CONTROLSTATIONPROVIDE 8 SCENE DIGITAL CONTROL STATION. PROVIDE SCENE PROGRAMMING AS DESIRED BY OWNER PRIOR TO PROJECTCLOSEOUT. RAISE/LOWER BUTTONS SHALL ADJUST THE DEFAULT LIGHT LEVEL OF THE SELECTED SCENE, PROPORTIONATELYTO THE SCENE.LIGHT DIMMING MODULENLIGHT #NPP16D(1) RELAY AND (1) 0-10V CLASS 1 DIMMINGOUTPUTPROVIDE LIGHTING CONTROL/DIMMING MODULE TO CONTROL LIGHTING ZONES AS INDICATED. CONNECT LIGHTING CONTROLMODULE TO LOCAL DISTRIBUTED, DIGITAL LIGHTING CONTROL NETWORK VIA CAT-5E CABLING PER MANUFACTURERSRECOMMENDATIONS. CABLING TO BE PLENUM RATED. CONNECT LINE SIDE OF MODULE TO UNSWITCHED CIRCUIT, ANDEXTEND LOAD SIDE SWITCHED CONDUCTORS AND CLASS 1 DIMMING CIRCUIT (2#16) TO LIGHTING ZONES AS INDICATED.NETWORK CABLE HOMERUNS SHALL TERMINATE AT NEAREST NETWORK BRIDGE.LIGHT DIMMING MODULE - ELV/MLVNLIGHT #NSP5-PCD(1) SECONDARY RELAY AND DIMMING PACK (ELV)PROVIDE LIGHTING CONTROL/DIMMING MODULE TO CONTROL LIGHTING ZONES AS INDICATED. MODULE SUITABLE FORELECTRONIC LOW VOLTAGE AND MAGNETIC LOW VOLTAGE DIMMING LOADS. CONNECT LIGHTING CONTROL MODULE TO LOCALDISTRIBUTED, DIGITAL LIGHTING CONTROL NETWORK VIA CAT-5E CABLING PER MANUFACTURER'S RECOMMENDATIONS.CABLING TO BE PLENUM RATED WHERE INSTALLED IN PLENUM SPACE. CONNECT LINE SIDE OF MODULE TO UNSWITCHEDCIRCUIT, AND EXTEND LOAD SIDE SWITCHED CONDUCTORS TO LIGHTING ZONES AS INDICATED. NETWORK CABLE HOMERUNSSHALL TERMINATE AT NEAREST NETWORK BRIDGE.WIRELESS LIGHTING CONTROL ANTENNANLIGHT #NECYD NLTAIRPROVIDE WIRELESS LIGHTING CONTROL ANTENNA WITH USB PATCH CABLE TO CONNECT TO HEAD END SYSTEM CONTROLLER('GTWY'). VERIFY MOUNTING LOCATION WITH MANUFACTURER FOR COMMUNCATION WITH SITE POLES AS SHOWN ON SITEPLAN. VERIFY USB CABLE LENGTH, PROVIDE EXTENDER AND POWER SUPPLY AS REQUIRED TO CONNECT ANTENNA TO GTWY.OCCUPANCY SENSORNLIGHT #NCM PDTCEILING-MOUNTED NETWORK OCCUPANCYSENSORPROVIDE DUAL TECHNOLOGY, NETWORK LEVEL OCCUPANCY SENSOR, CAPABLE OF DETECTING SMALL MOTION. OCCUPANCYSENSOR TO CONTROL ZONE(S) AS INDICATED BY LOWERCASE LETTERS. WHERE NO LETTER IS INDICATED, OCCUPANCYSENSOR TO CONTROL ALL ZONES IN THAT SPACE. CONNECT OCCUPANCY SENSOR TO DIGITAL LIGHTING CONTROL NETWORKVIA CAT-5E NETWORK CABLE. OCCUPANCY SENSORS SHALL BE CONFIGURED TO OPERATE IN 'VACANCY' MODE: MANUAL ON /AUTO OFF.POWER SUPPLYKLUS#010-96-2424VDC POWER SUPPLY FOR UP TO 96W WITH 0-10V DIMMING FOR TYPE LED TAPE ACCENT LIGHTS. CONNECT LINE SIDE TOADJACENT LIGHTING DIMMING MODULE SWITCH LEG AND 0-10V DIMMING CIRCUIT. PROVIDE 24V CIRCUIT FROM LOAD SIDE TOLOW VOLTAGE ACCENT LIGHTS VIA FACTORY CONNECTORS AND WIRING HARNESS. FIELD COORDINATE MOUNTING INNEAREST ACCESSIBLE CEILING OR IN CASEWORK WHERE APPLICABLE.POWER SUPPLYWAC LIGHTING#9150-TRN-SS12VDC MAGNETIC POWER SUPPLY FOR UP TO 150W FOR TYPE W06 ACCENT SCONCES. CONNECT LINE SIDE TO ADJACENTLIGHTING DIMMING MODULE SWITCH LEG. PROVIDE12V CIRCUIT FROM LOAD SIDE TO LOW VOLTAGE ACCENT LIGHTS VIAFACTORY CONNECTORS AND WIRING HARNESS. ONE POWER SUPPLY PER (2) COLUMNS / (8) FIXTURES.RECEPTACLE CONTROL MODULENLIGHT #NPP20 PL(1) RELAY PLUG LOAD CONTROLLERPROVIDE RECEPTACLE CONTROL MODULE TO CONTROL RECEPTACLE LOADS AS INDICATED BY SYMBOL. CONNECT CONTROLMODULE TO LOCAL DISTRIBUTED, DIGITAL LIGHTING CONROL NETWORK VIA CAT-5E CABLING PER MANUFACTURERSRECOMMENDATIONS. RECEPTACLE CONTROLLER TO BE CONNECTED AS PART OF THE LOCAL LIGHTING CONTROL NETWORK.NETWORK CABLE HOMERUNS SHALL TERMINATE AT NEAREST NETWORK BRIDGE.LINE VOLTAGE WALL SWITCHLOWERCASE LETTER SUBSCRIPTS INDICATE NUMBER OF POLES/BUTTONS. EACH LETTER REPRESENTS A ZONES OF CONTROL(I.E. SUBSCRIPT 'ab' INDICATES A 2-POLE, 2-BUTTON WALL SWITCH)OCCUPANCY SENSOR WALL SWITCHSENSOR SWITCH#WSX-D (FOR SINGLE ZONE DIMMING)PROVIDE LINE-VOLTAGE WALL SWITCH OCCUPANCY SENSOR WITH 0-10V DIMMING CAPABILITY. CONNECT UNSWITCHED HOTTO LINE SIDE OF DEVICE AND EXTEND SWITCH LEG AND 0-10V DIMMING CIRCUIT TO LUMINAIRES IN THE ROOM.GUEST UNIT LUMINAIRE SCHEDULETYPESYMBOLMFGR & CATALOG NUMBERDRIVERMOUNTING LIGHTSOURCELUMENOUTPUTINPUTWATTSLUMENS/WATTNOTESG.B06ALPHABET#NU6RD SW 15LM 27K 80 HE60 WH WH NC 120 ELV1120VRECESSED LED, 2700K 1200LM 14W 86 GUEST UNIT 6" RECESSED DOWNLIGHT.NON-CONDUCTIVE TRIM FOR SHOWER INSTALLATION.G.F01REMINGTON LIGHTING#STYLE 15304120VSURFACE (3) E26 LEDREPLACEMENT,2700K-30WMAX(10WLAMPS)- GUEST UNIT SURFACE LIGHTG.P01REMINGTON LIGHTING#STYLE 15303120-277VPENDANT,+6'-0"(1) E26 LEDREPLACEMENT,2700K-15WMAX- GUEST UNIT DECORATIVE PENDANTG.W01WAC LIGHTING#WS-W61806-BK120VWALL, +6'-0" LED, 3000K 773LM 9W 86 GUEST UNIT WALL SCONCE, WET LOCATION RATED(BALCONY)G.Z24JUNO#UCES 24IN SWW6 90CRI WH M6120VUNDERCABINETSURFACELED, 3000K 825LM 11W 75 GUEST UNIT UNDERCAB LIGHTING. FIELD SET COLORTEMPERATURE TO 3000K32 MERCHANT STREET, SUITE 208HONOLULU, HI 96813808-352-5299OWNER:HOMEWOOD SUITES by HILTON SPOKANE VALLEY, WA 13515 E. Carlisle Avenue Spokane Valley, WA 99216FSC PROJECT NO. 21012PERMITDOCUMENTSMay 31, 2024GL8 MirabeauPoint, LLCTMK:PID: 45101.0401 10909 E. Pierce LaneSpokane, WA 99206(509) 919-0901Revision ScheduleNumber Description Date5915 S REGAL STREETSUITE 201SPOKANE, WA 99223PH: 509.473.9218Kelly@kwrllc.comwww.kwrllc.com5/30/2024 12:49:11 PMSTATE OF WASHINGTONREGISTERED PROFESSIONAL ENG INEER48350 KELLY A N DREW WATERMAN05.31.24LUMINAIRESCHEDULESE-005 S02S02S02S02S03-2S03-2S03-2S03-2S02S03S03S02S02S02EXISTING UTILITYPRIMARY JUNCTIONENCLOSUREUG/E UG/E UG/E UG/E UG/E UG/E UG/E UG/E UG/E UG/E UG/E UG/E UG/E UG/E UG/E UG/E UG/E UG/EUG/EUG/EUG/E124356EV-1EV-21E-104UTILITY TRANSFORMEREV-1,3EV-5,7ATS-YUG/EH11-1H11-1H11-1H11-1H11-1H11-3H11-3H11-3H11-3H11-3H11-3H11-3H11-3H11-3NEW BUILDINGext1ext1ext1ext1ext1ext1ext1ext1ext1ext1ext1ext1ext1S12S12H11-1H11-1ext2ext2FP-1FP-2FP-3WPMONUMENT SIGNWPDRIVEWAY SIGNWPDRIVEWAY SIGNHH7HH7HH7999888L12-15L12-17L12-17L12-17L12-19L12-19HHHHHHHHHHHHHH10101010101010HHUG/T UG/T UG/T UG/T UG/T UG/T UG/T UG/T UG/T UG/T UG/T HHUG/T1111 GEN-YUTILITY METERMSB1E-102TYP2E-102TYP1E-1032 / 3E-10332 MERCHANT STREET, SUITE 208HONOLULU, HI 96813808-352-5299OWNER:HOMEWOOD SUITES by HILTON SPOKANE VALLEY, WA 13515 E. Carlisle Avenue Spokane Valley, WA 99216FSC PROJECT NO. 21012PERMITDOCUMENTSMay 31, 2024GL8 MirabeauPoint, LLCTMK:PID: 45101.0401 10909 E. Pierce LaneSpokane, WA 99206(509) 919-0901Revision ScheduleNumber Description Date5915 S REGAL STREETSUITE 201SPOKANE, WA 99223PH: 509.473.9218Kelly@kwrllc.comwww.kwrllc.com5/30/2024 12:49:19 PMSTATE OF WASHINGTONREGISTERED PROFESSIONAL ENG INEER48350 KELLY A N DREW WATERMAN05.31.24ELECTRICAL SITEPLANE-101SCALE:1" = 25'-0"ELECTRICAL SITE PLANGENERAL NOTESA. COORDINATE ALL ELECTRICAL UTILITY WORK WITH AVISTA UTILITIES.IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO ADHERE TO THEPUBLISHED DOCUMENTS AND STANDARDS OF THE SERVINGELECTRICAL UTILITY. CONTRACTOR TO PROVIDE NEW VAULT,TRANSFORMER VAULT AND PAD, AND RACEWAY FOR PRIMARY ANDSECONDARY SERVICE CONDUCTORS. CONTACT:TODD HARMON, (509) 503-8094, todd.harmon@avistacorp.comB. THIS PLAN MAY NOT SHOW ALL EXISTING BURIED UTILITIES.CONTACT UNDERGROUND LOCATION SERVICE PRIOR TOEXCAVATION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALLCOSTS ASSOCIATED WITH UNDERGROUND LOCATING AND ANYREPAIRS FROM FAILING TO TAKE NECESSARY PRECAUTIONS PRIORTO EXCAVATION.C. UNDERGROUND RACEWAY SHALL BE PLACED MINIMUM 24" BELOWFINISH GRADE. UNDERGROUND UTILITY CONDUIT SHALL BE PLACED36" BELOW FINISH GRADE, OR AS DIRECTED BY THE SERVINGUTILITY.D. ALL SITE BRANCH CIRCUITS SHALL BE 1"C,3#10,#10G UNLESSOTHERWISE NOTED.E. SEE SHEETS E-201A AND E-201B FOR EXTERIOR LIGHTING CONTROLMODULE LOCATIONS.F. DESIGN INTENT FOR EXTERIOR LIGHTING CONTROL ZONES 'ext1' AND'ext2' IS WIRELESS CONTROL VIA INTEGRAL CONTROL MODULES. SEESHEET E-201A FOR ANTENNA LOCATION. SITE POLES SHALL BEENERGIZED FROM DUSK TO DAWN. POLES SHALL DIM BY 50% WHENNO MOTION IS DETECTED FOR 15 MINUTES.FLAG NOTESNEW UTILITY TRANSFORMER FOR PERMANENT SERVICE EQUIPMENT.CONTRACTOR TO PROVIDE CONCRETE PAD, EXCAVATION, ANDMETER ENCLOSURE, UTILITY TO PROVIDE TRANSFORMER ANDPRIMARY AND SECONDARY CONNECTIONS. COORDINATESCHEDULING AND INSTALLATION WITH SERVING UTILITY. PROVIDECONCRETE FILLED STEEL BOLLARDS FOR TRAFFIC PROTECTION ASREQUIRED BY UTILITY.PROVIDE TRENCHING AS REQUIRED TO INTERCEPT EXISTING AVISTAUNDERGROUND PRIMARY IN THIS APPROXIMATE LOCATION, FORROUTING TO NEW UTILITY TRANSFORMER. VERIFY EXACT LOCATIONAND REQUIREMENTS WITH AVISTA UTILITIES PRIOR TOCOMMENCEMENT OF WORK.PROVIDE SECONDARY TRENCHING, CONDUIT, CONDUCTORS ANDBACKFILL. SEE ONE-LINE DIAGRAM FOR ADDITIONAL INFORMATION.LOCATION OF MAIN SERVICE EQUIPMENT / MAIN DISCONNECT,SHOWN FOR REFERENCE. SEE SHEET E-501 FOR EXACT LOCATION.NEW LEGALLY REQUIRED STANDBY, NATURAL GAS GENERATOR INWEATHERPROOF SOUND ATTENUATING ENCLOSURE. COORDINATEFINAL EXACT LOCATION WITH OWNER AND ARCHITECT PRIOR TOROUGH-IN. GENERATOR AND ASSOCIATED FUEL CONNECTION SHALLMAINTAIN MINIMUM 10' CLEARANCE FROM UTILITY TRANSFORMER.PROVIDE CONCRETE PAD AND DEDICATED GROUNDING ELECTRODESYSTEM PER DETAILS ON SHEETS E-102 AND E-701. SEE ONE-LINEDIAGRAM AND SPECIFICATIONS FOR ADDITIONAL SIZING ANDINFORMATION. EMERGENCY STOP BUTTON SHALL BE MOUNTEDDIRECTLY TO GENERATOR ENCLOSURE.NEW UNDERGROUND FEEDER FROM GENERATOR. SEE ONE-LINEDIAGRAM ON SHEET E-601 FOR ADDITIONAL INFORMATION.PROVIDE HANDHOLE ADJACENT TO INTERNALLY LIT MONUMENT /DRIVEWAY ENTRY SIGNS. PROVIDE HANDHOLE FOR ROUTINGBRANCH CIRCUIT.ROUTE BRANCH CIRCUIT VIA CONTROL MODULE SHOWN ON SHEETE-501 FOR TIME-CLOCK CONTROL. SEE SHEET E-501 FORADDITIONAL INFORMATION.PROVIDE 120V BRANCH CIRCUIT FOR FLAGPOLE LIGHT. LIGHT ISINTEGRAL TO FLAGPOLE, MOUNTED AT TOP OF POLE. COORDINATEWITH POLE INSTALLER FOR WIRING REQUIREMENTS. FLAGPOLELIGHT CONTAINS INTEGRAL DAYLIGHT SENSOR FOR CONTROLS.PROVIDE HANDHOLE WITH (2)1"C ROUTED TO PANEL EV IN MAINELECTRICAL ROOM, FOR FUTURE EV CHARGING CIRCUITS.PROVIDE (2)2"C FROM STREET-SIDE INFRASTRUCTURE INTOBUILDING FOR ISP SERVICE CABLING. COORDINATE WITH OWNERSELECTED ISP FOR EXACT ROUTING AND REQUIREMENTS.ROUTING/LOCATIONS SHOWN ARE PRELIMINARY. ROUTE CONDUITSTO PBX/MDF ROOM ON SECOND FLOOR, SHOWN ON SHEET E-302A1234567891011 DETAIL NOTES:1. CONCRETE TO MEET DIVISION 3SPECIFICATIONS (033000).CONCRETE 30 DAY STRENGTH6000-7000 PSI.2. BASIS OF DESIGN IS BASED ONPRE-CAST BASE.3. PROVIDE 1" PVC COUPLINGS ASREQUIRED FOR RACEWAYS SHOWN.HOMERUN OR NEXT POLETO NEXT POLEFINISHED GRADELIGHT POLE3"x5" HAND HOLE WITHTAMPER RESISTANT SCREWS2-PIECE BOLT COVER PLATE1" CHAMFERSMOOTH SURFACEANCHOR BOLTS PER POLEMANUFACTURER'SREQUIREMENTSREBAR, #3 HOOPS @ 12" O.C.,#5 VERTICAL, 4 PIECES(4) 1" PVC SCH. 40 CONDUIT1" PVC COUPLERUNDISTURBED SOIL ORSELECT BACKFILL COMPACTED30"72"24" MIN18" ROUND CONCRETE BASE24"LIGHT POLE3"x 5" HAND HOLE WITHTAMPER RESISTANT SCREWS2-PIECE BOLD COVER PLATE1" CHAMFERSMOOTH SURFACEFINISHED GRADEANCHOR BOLTS PER POLEMANUFACTURER'S REQUIREMENTS(4) 1" PVC SCH. 40 CONDUIT1" PVC COUPLERUNDISTURBED SOIL OR SELECTBACKFILL COMPACTED.REBAR, #3 HOOPS AT 12" O.C.,#5 VERTICAL, 4 PIECESCONCRETE MOW STRIPHOMERUN OR NEXT POLE24" ROUND CONCRETE BASE72"6" 24" MIN TO NEXT POLEDETAIL NOTES:1. CONCRETE TO MEET DIVISION 3SPECIFICATIONS (033000).CONCRETE 30 DAY STRENGTH6000-7000 PSI.2. BASIS OF DESIGN IS BASED ONPRE-CAST BASE.3. PROVIDE 1" PVC COUPLINGS ASREQUIRED FOR RACEWAYS SHOWN.18"(2) 3/8-16 UNCSTAINLESS STEEL HEXHEAD BOLT W/WASHER1/2" x 2" PULL SLOT.5 COF SKID RESISTANTSURFACE(2) 2-1/2" x 4"MOUSEHOLESBACKFILL4" WIDE YELLOWMARKING TAPEGRADE12" 30"3/4" MINUS GRAVEL BED,CONDUITS WHERE NECESSARYIN ROCKY AREAS, OTHERWISEUSE SELECTED NATURAL FILLSCHEDULE 40 PVCCONDUIT, SIZE/QUANTITYAS NOTED ON PLANSNO SPLICESIN J-BOXQUAZITE FLUSH IN-GRADEPOLYMER ENCLOSUREPHASE CONDUCTORS ORCABLING AS REQUIREDBUSHING (TYPICAL)4" MINIMUMINCOMING ANDOUTGOINGCONDUITS, SIZE ASNOTED ON PLANSPROVIDE 3/4" MINUS GRAVEL 6"DEEP BELOW AND 6" BEYONDALL SIDES OF PULL BOXFLUSH IN-GRADE POLYMER LID(2) 3/8-16 UNCSTAINLESS STEEL HEXHEAD BOLT W/WASHER1/2" x 2" PULL SLOT.5 COF SKID RESISTANTSURFACE(2) 2-1/2" x 4"MOUSEHOLESDETAIL NOTES:1. CONCRETE TO MEET DIVISION 3SPECIFICATIONS (033000).CONCRETE 30 DAY STRENGTH6000-7000 PSI.2. BASIS OF DESIGN IS BASED ONPRE-CAST BASE.3. PROVIDE 1" PVC COUPLINGS ASREQUIRED FOR RACEWAYS SHOWN.HOMERUN OR NEXT POLETO NEXT POLEFINISHED GRADEBOLLARD LUMINAIREANCHOR BOLTS PER POLEMANUFACTURER'SREQUIREMENTSREBAR, #3 HOOPS @ 12" O.C.,#5 VERTICAL, 4 PIECES(2) 1" PVC SCH. 40 CONDUIT1" PVC COUPLERUNDISTURBED SOIL ORSELECT BACKFILL COMPACTED48" 24" MIN12" ROUND CONCRETE BASE12"32 MERCHANT STREET, SUITE 208HONOLULU, HI 96813808-352-5299OWNER:HOMEWOOD SUITES by HILTON SPOKANE VALLEY, WA 13515 E. Carlisle Avenue Spokane Valley, WA 99216FSC PROJECT NO. 21012PERMITDOCUMENTSMay 31, 2024GL8 MirabeauPoint, LLCTMK:PID: 45101.0401 10909 E. Pierce LaneSpokane, WA 99206(509) 919-0901Revision ScheduleNumber Description Date5915 S REGAL STREETSUITE 201SPOKANE, WA 99223PH: 509.473.9218Kelly@kwrllc.comwww.kwrllc.com5/30/2024 12:49:28 PMSTATE OF WASHINGTONREGISTERED PROFESSIONAL ENG INEER48350 KELLY A N DREW WATERMAN05.31.24ELECTRICAL SITEDETAILSE-102SCALE:1SITE POLE BASE DETAIL (TYPES S02, S03)NTSSCALE:2FLUSH POLE BASE DETAIL (TYPE S12)NTSSCALE:4TRENCHING AND IN-GRADE HANDHOLD DETAILNTSSCALE:3LIT BOLLARD MOUNTING DETAIL (TYPE S21)NTS 3' MIN 3' MIN3' MIN10' MINTOP VIEWPAD-MOUNT EQUIPMENTACCESS DOORSCOOLING FINSPAD MOUNT TRANSFORMER TYPICAL CLEARANCESNOTES:1. DETAIL IS DIAGRAMMATIC; NOT ALL SCOPE IS SHOWN.2. DIMENSIONS ARE TYPICAL; VERIFY ALL DIMENSIONS AND INSTALLATION REQUIREMENTS WITH UTILITY REPRESENTATIVEPRIOR TO COMMENCEMENT OF WORK3. PROVIDED CONCRETE-FILLED STEEL BOLLARDS AS REQUIRED BY UTILITY. VERIFY QUANTITY AND SPACING PRIOR TOINSTALLATION.4. CONDUIT QUANTITIES AND SIZES SHOWN ARE DIAGRAMMATIC. PROVIDE ALL CONDUITS AS NOTED ON ONE-LINE DIAGRAMAND AS REQUIRED BY UTILITY.5. PROVIDE CT CONDUIT, MOUNTING EQUIPMENT, AND ENCLOSURE ONLY WHERE SHOWN ON SITE PLANHLC8"BAPVC CONDUIT SWEEPSCUSTOMER PVCCONCRETETRANSFORMER PAD6" MAXIMUM FROMBACK OF OPENING ONCUSTOMER SIDETRANSFORMER PAD (TOP VIEW)NOTES:1. DETAIL IS REFERENCED FROM AVISTA 'BLUE BOOK'. REFER TO AVISTA PUBLISHED STANDARDS AND COORDINATE WITHPROJECT COORDINATOR FOR FINAL REQUIREMENTS.2. DETAIL IS DIAGRAMMATIC; NOT ALL SCOPE IS SHOWN.3. DIMENSIONS ARE TYPICAL; VERIFY ALL DIMENSIONS AND INSTALLATION REQUIREMENTS WITH UTILITY REPRESENTATIVEPRIOR TO COMMENCEMENT OF WORK4. CONDUIT QUANTITIES AND SIZES SHOWN ARE DIAGRAMMATIC. PROVIDE ALL CONDUITS AS NOTED ON ONE-LINE DIAGRAMAND AS REQUIRED BY UTILITY.5. PROVIDE CT CONDUIT, MOUNTING EQUIPMENT, AND ENCLOSURE ONLY WHERE SHOWN ON SITE PLAN12" MIN15' MAXMAINTAIN 3" CLEARANCEFROM OTHER OPENINGS ANDINSTALLED CONDUCTORS4" 6" MAX HIGHVOLTAGE SIDELOWVOLTAGE SIDEGROUND SLEEVEFINISH GRADETRANSFORMER PAD (SIDE VIEW)NOTES:1. DETAIL IS REFERENCED FROM AVISTA 'BLUE BOOK'. REFER TO AVISTA PUBLISHED STANDARDS AND COORDINATE WITHPROJECT COORDINATOR FOR FINAL REQUIREMENTS.24"NEW GENERATORSTEEL REINFORCEMENT BARSSHALL BE #4 BARS, NOT TOEXCEED 12" SPACING.36"36"12" MIN 8" MINDETAIL NOTES:1. SLAB DESIGN SHOWN IS INTENDED TO SHOW DIMENSIONS AND GENERAL DESIGN INTENT. CONTRACTOR SHALL PROVIDESTRUCTURAL CONCRETE PAD, STRUCTURALLY DESIGNED TO SUPPORT THE ENTIRE GENERATOR ASSEMBLY. SUBMIT SHOPDRAWINGS AND STRUCTURAL CALCULATIONS FOR REVIEW PRIOR TO POURING CONCRETE PAD.2. COORDINATE WITH GENERATOR MANUFACTURER AND MECHANICAL CONTRACTOR FOR ALL SLAB PENETRATIONS FOR FEEDERCONDUITS, CONTROLS CONDUITS, AND ALL NATURAL GAS LINE REQUIREMENTS.3. PROVIDE 1"C TO GENERATOR ACCESSORY FOR CONTROL WIRING PER MANUFACTURER ELECTRICAL REQUIREMENTS. COORDINATEFINAL QUANTITY OF GENERATOR ACCESSORIES WITH MANUFACTURER PRIOR TO ROUGH-IN.24" MIN4"C TO ATS1"C TO ATS FOR CONTROL WIRING1"C TO GENERATOR ANNUNCIATOR1"C TO GENERATOR EPO1"C TO GENERATOR ACCESSORY 11"C TO GENERATOR ACCESSORY 21"C TO GENERATOR ACCESSORY 31"C TO GENERATOR ACCESSORY 41"C TO GENERATOR ACCESSORY THATMAY DIFFER PER MANUFACTURER.32 MERCHANT STREET, SUITE 208HONOLULU, HI 96813808-352-5299OWNER:HOMEWOOD SUITES by HILTON SPOKANE VALLEY, WA 13515 E. Carlisle Avenue Spokane Valley, WA 99216FSC PROJECT NO. 21012PERMITDOCUMENTSMay 31, 2024GL8 MirabeauPoint, LLCTMK:PID: 45101.0401 10909 E. Pierce LaneSpokane, WA 99206(509) 919-0901Revision ScheduleNumber Description Date5915 S REGAL STREETSUITE 201SPOKANE, WA 99223PH: 509.473.9218Kelly@kwrllc.comwww.kwrllc.com5/30/2024 12:49:32 PMSTATE OF WASHINGTONREGISTERED PROFESSIONAL ENG INEER48350 KELLY A N DREW WATERMAN05.31.24ELECTRICAL SITEDETAILSE-103SCALE:2AVISTA TRANSFORMER CLEARANCE DETAILNO SCALESCALE:3AVISTA TRANSFORMER DETAILNO SCALESCALE:1GENERATOR MOUNTING PAD DETAILNTS 001OUTDOORSTORAGE002OPEN TRASHENCLOSUREC96C96EOD-1J1LSSLSS-2,4LSS-1LSS-1LSS-3LSS-3LSS-3LSS-3UH-02LSS-5,7+44"+44"+44"+44"232 MERCHANT STREET, SUITE 208HONOLULU, HI 96813808-352-5299OWNER:HOMEWOOD SUITES by HILTON SPOKANE VALLEY, WA 13515 E. Carlisle Avenue Spokane Valley, WA 99216FSC PROJECT NO. 21012PERMITDOCUMENTSMay 31, 2024GL8 MirabeauPoint, LLCTMK:PID: 45101.0401 10909 E. Pierce LaneSpokane, WA 99206(509) 919-0901Revision ScheduleNumber Description Date5915 S REGAL STREETSUITE 201SPOKANE, WA 99223PH: 509.473.9218Kelly@kwrllc.comwww.kwrllc.com5/30/2024 12:49:36 PMSTATE OF WASHINGTONREGISTERED PROFESSIONAL ENG INEER48350 KELLY A N DREW WATERMAN05.31.24STORAGE SHEDENLARGEDELECTRICAL PLANE-104GENERAL NOTESA. UNDERGROUND RACEWAY SHALL BE PLACED MINIMUM 24" BELOWFINISH GRADE. UNDERGROUND UTILITY CONDUIT SHALL BE PLACED36" BELOW FINISH GRADE, OR AS DIRECTED BY THE SERVINGUTILITY.B. ALL SITE BRANCH CIRCUITS SHALL BE 1"C,3#10,#10G UNLESSOTHERWISE NOTED.C. COORDINATE WITH MECHANICAL, PRIOR TO ROUGH-IN FOR FINALEQUIPMENT INSTALL LOCATIONS AND CONNECTIONSREQUIREMENTS.D. MAINTAIN 36" WORKING CLEARANCE IN FRONT OF ELECTRICALPANELS PER NEC REQUIREMENTS.FLAG NOTESPROVIDE 3/4"C AND CONTROL WIRING FROM ASSOCIATEDOVERHEAD DOOR OPERATOR TO JUNCTION BOX FOR MANUALCONTROL OF OVERHEAD DOOR. COORDINATE FINAL JUNCTION BOXLOCATION AND RACEWAY REQUIREMENTS WITH DOOR INSTALLERPRIOR TO ROUGH-IN.UNIT HEATER CONNECTION LOCATION IS PRELIMINARY. VERIFYEXACT LOCATION WITH MECHANICAL INSTALLER PRIOR TOROUGH-IN.1SCALE:1STORAGE SHED ELECTRICAL PLAN1/4" = 1'-0"2 533.16.12.1DC.1ECCBB18.1941.1AA78610W03W01W02W02ENEMA 4XNEMA 4XB22AEB22AW02B22AEB22AB22AER44R44R44R44C48EC48C48C48ER25B26B26B26B22AER27R27R27R27R27R27B25B25R251B25B25B25B25B25B20AB20AB20AR25E1dz1dz1dz2dz2LDM1LDM1dz1LDM1dz2R25R25ER25R25R25R25R25R25ER25R25B26B26B22AEP03P03B22B22B22AP03P03B22B22B26B26B22AEB22AR01-11R01-1111W24W24B22B22B22B22B22B221R26R26R26b,dz1b,dz2LDM1LDM1b,dz1LDM1b,dz2LDM1LDM1LDM1LDM1W01W01W01W01W01W01W02EW02W02G02EG02EG02EG02EGTWYW03EB06B06C96E BRDGC96 C96 C96EZ02aaaaaLDM1bb2abOSOSC48 OSOSOSOSOSOSX01X01X01X01X04OSOSOSB06EB06B06EB06B06B06EB06B06B06EB06B06EB06B06EB06B06B06E1TYP23455B20AB20A4X01X016dz1dz1dz2dz2DLdz1dz2DLdz1dz2LDM1LDM1dz1LDM1dz2W03DLdz1dz2aaB25C48W04W04W04W04W04W04W04W04W04W04W04W0411OSLDM1 7W48EW48Eext4ext4ext4ext5ext5ext5ext5ext5ext5S21S21S21S21S21S21S21S21S21S21S21S21S21ext10ext10ext10ext10ext10ext10ext10ext10ext10ext10ext10ext10B22 B2233aaR08B21EB21 B21EG01EG01EG01EH11LDM1LDMV H11-5H11-5H11-5 H11-5H11-5H11-5H11-5 H11-5H11-5H11-5H11-5H11-5H11-5H11-5H11-5X04S21ext10S21ext10S21ext10H11-7 H11-7 H11-7H11-7H11-7H11-7H11-7H11-7H11-7H11-7H11-7H11-7H11-7H11-7H11-7H11-7H11-7H11-7H11-7H11-7H11-7H11-7H11-7H11-7H11-7H11-7H11-7H11-7H11-7 H11-9H11-9H11-9ELEV-5ELEV-5ELEV-5ELEV-5H11-7H11-7H11-7H11-7H11-7H11-7H11-7H11-7H11-7H11-7H11-7H11-7H11-7H11-7H11-7PS1PS1PS1H11-11 H11-11H11-11H11-11H11-11H11-11H11-11H11-11H11-11H11-11H11-11H11-11H11-11H11-11H11-11H11-11H11-11H11-11H11-11H11-11H11-11H11-11H11-11H11-11H11-11H11-11H11-11H11-11H11-11H11-11L12-36L12-36L12-36L12-36L12-36L12-36H11-7H11-7H11-7H11-7H11-7H11-7H11-7H11-7H11-7H11-7H11-7H11-7H11-7H11-7H11-7H11-7H11-7H11-7H11-7H11-7H11-7H11-7H11-7 H11-7H11-7H11-7H11-7H11-7L12-36L12-36L12-36L12-36L12-36H11-7H11-7H11-5 H11-5bbbLDMVLDMVbbbbbbbbbbbbH11-5H11-5a H11-5+8'-0"104ELECTRICAL101POOL/SPLASHPAD102POOL RESTROOM100PUBLIC CORRIDOR108WATER HEATER& FIRE105BOH LAUNDRY107LINEN DISCHARGE& SORTING110EMPLOYEEROOM112LAUNDRYLOUNGE110AEMP RR ADA140LINEN CHUTE111ELEV 1113ELEV 2110BEMP RR114FITNESS116MEN'SRESTROOM115WOMEN'SRESTROOM119MEETINGSTORAGE120MEETING ROOM118GUEST STORAGE106STAIR 1117ELEVATOR LOBBY103POOL MEP100AVESTIBULE109AHOUSEKEEPINGOFFICE105ABOH DRYERext10ext7ext7ext7nnnnnnn nnnnnnnnnnnnnnnnnnooonC96H11-71OSnnnLDM1LDM1aLDM1bLDM1oLDM1LDM1ext4ext7LCM1ext5LCM1ext5LDM1ext7H11-15H11-15H11-15H11-15H11-15H11-15H11-15H11-15H11-15H11-15H11-15H11-15H11-15ext10LCM1L12-38H11-15H11-15H11-15H11-15H11-15H11-15H11-15H11-15H11-15H11-15H11-15H11-15H11-15H11-15H11-15ext10LCM1L1246LDM1477588891011LDM1R08 a R08E a R08E a R08 a R08 a R08E a R08 a R08 a R08E a R08 a W04H11-5bH11-7 H11-7 H11-7H11-7H11-7 H11-7 H11-7 H11-7 H11-7H11-73E-102TYPE32 MERCHANT STREET, SUITE 208HONOLULU, HI 96813808-352-5299OWNER:HOMEWOOD SUITES by HILTON SPOKANE VALLEY, WA 13515 E. Carlisle Avenue Spokane Valley, WA 99216FSC PROJECT NO. 21012PERMITDOCUMENTSMay 31, 2024GL8 MirabeauPoint, LLCTMK:PID: 45101.0401 10909 E. Pierce LaneSpokane, WA 99206(509) 919-0901Revision ScheduleNumber Description Date5915 S REGAL STREETSUITE 201SPOKANE, WA 99223PH: 509.473.9218Kelly@kwrllc.comwww.kwrllc.com5/30/2024 12:49:45 PMSTATE OF WASHINGTONREGISTERED PROFESSIONAL ENG INEER48350 KELLY A N DREW WATERMAN05.31.24FIRST FLOORLIGHTING PLAN -AREA AE-201AGENERAL NOTESA. PROVIDE UN-SWITCHED HOT CONDUCTOR TO ALL EMERGENCY LUMINAIRESAND EXIT SIGNS. EMERGENCY LUNIMAIRES ARE INDICATED BY HATCHINGAND/OR WITH AN 'E' DESIGNATION ON THE END OF FIXTURE NAME.B. PROVIDE ALL HARDWARE AND ACCESSORIES REQUIRED TO MOUNTLUMINAIRE IN LOCATIONS SHOWN INCLUDING ALL MOUNTING BRACKETS,T-BAR HANGERS, CANOPIES, ETC.C. LIGHTING CONTROLS BASIS OF DESIGN IS A DIGITAL DISTRIBUTED,NETWORKABLE SYSTEM CONSISTING OF CONTROL/DIMMING MODULES ANDBOTH MANUAL AND AUTOMATIC INPUT DEVICES (OCCUPANCY SENSORS,DAYLIGHT SENSORS, AND MANUAL CONTROL STATIONS. EACH SPACE SHALLCONSIST OF A LOCAL LIGHTING CONTROL NETWORK, WITH ALL CONTROLDEVICES IN THE SPACE CONNECTED TOGETHER VIA CAT-5E NETWORK IN ADAISY CHAIN TOPOLOGY. EACH SPACE SHALL HAVE A NETWORK HOME RUNOF CAT-5E CABLE THAT TERMINATES ON A DEDICATED BRIDGE PORT ON THENEAREST NETWORK BRIDGE. INTERIOR AND EXTERIOR LIGHTING ZONESSHALL TERMINATE ON DEDICATED NETWORK BRIDGES OR BRIDGE HUBS.ACTUAL QUANTITY OF BRIDGES NOT SHOWN AND SHALL BE DETERMINED ONMANUFACTURER'S SHOP DRAWINGS.D. ALL OCCUPANCY SENSORS SHALL BE SET TO A DEFAULT TIME DELAY OF 15MINUTES. OCCUPANCY SENSORS IN RESTROOMS AND CORRIDORS SHALL BESET TO AUTO ON, AUTO OFF. ALL OTHER OCCUPANCY SENSORS SHALL BESET TO MANUAL ON, AUTO OFF UNLESS OTHERWISE NOTED.E. EXTERIOR LIGHTING CONTROL ZONES SEQUENCE OF OPERATION ASFOLLOWS:- ext3: FULL BRIGHTNESS FROM DUSK TO DAWN, FOR OCCUPANT SAFETY.- ext4: FULL BRIGHTNESS FROM DUSK TO DAWN, FOR OCCUPANT SAFETY- ext5: FULL BRIGHTNESS FROM DUSK TO 11PM, 30% BRIGHTNESS FROM 11PM TO 6AM, FULL BRIGHTNESS FROM 6AM TO DAWN.- ext6: FULL BRIGHTNESS FROM DUSK TO 11PM, 30% BRIGHTNESS FROM 11PM TO 6AM, FULL BRIGHTNESS FROM 6AM TO DAWN.- ext7: FULL BRIGHTNESS FROM DUSK TO DAWN, FOR OCCUPANT SAFETY.- ext8: FULL BRIGHTNESS FROM DUSK TO 11PM, 30% BRIGHTNESS FROM 11PM TO 6AM, FULL BRIGHTNESS FROM 6AM TO DAWN.- ext9: FULL BRIGHTNESS FROM DUSK TO 11PM, 30% BRIGHTNESS FROM 11PM TO 6AM, FULL BRIGHTNESS FROM 6AM TO DAWN.- ext10: FULL BRIGHTNESS FROM DUSK TO DAWN, FOR OCCUPANT SAFETY.COORDINATE SCHEDULING AND BRIGHTNESS LEVELS WITH OWNER PRIORTO PROJECT CLOSEOUT.FLAG NOTESMOUNT LIGHTING CONTROL MODULE TO JUNCTION BOX ABOVE ACCESSIBLE CEILING.CONNECT UN-SWITCHED CIRCUIT TO LINE SIDE OF MODULE AND EXTEND SWITCHEDCIRCUIT AND 0-10V DIMMING CIRCUIT TO LIGHTING ZONES INDICATED. IN AREASWITH INACCESSIBLE CEILINGS, LOCATE DEVICES IN NEAREST ADJACENT ACCESSIBLECEILING OR NON-PUBLIC UTILITY SPACE. DEVICES SHALL BE LOCATEDCONSISTENTLY FOR SIMILAR SPACES (I.E. ABOVE DOORS IN OFFICES).MOUNT BRIDGE DEVICE ABOVE ACCESSIBLE CEILING. BRIDGE TO RECEIVE HOMERUNS FROM LOCAL LIGHTING CONTROL NETWORK DAISY CHAINS IN ADJACENTAREAS. NOT ALL BRIDGES ARE SHOWN, PROVIDE BRIDGES AS REQUIRED TO ACCEPTA DEDICATED LOCAL NETWORK HOMERUN FROM EACH SPACE. REFER TOMANUFACTURER'S SHOP DRAWINGS FOR FINAL QUANTITIES.LIGHTING SYSTEM CONTROLLER. PROVIDE 120V POWER SUPPLY AND NETWORKBRIDGE TO ORIGINATE LIGHTING CONTROL NETWORK BUS. CONNECT TO ADDITIONALBRIDGES AS REQUIRED TO EXTEND LIGHTING CONTROL NETWORK THROUGHOUTTHE BUILDING AREA.LIGHTING CONTROLS IN THIS SPACE SHALL UTILIZE TIME-BASED AUTOMATICCONTROL BASED ON BUSINESS HOURS DEFINED BY THE OWNER DURING STARTUP.LIGHTING CONTROL MODULES AND DEVICES TO BE CONNECTED TO DIGITALLIGHTING CONTROL NETWORK TO OBTAIN TIME-CLOCK SIGNAL. CONTROL STATIONSIN THIS SPACE ARE INTENDED FOR DIMMING CONTROL AND 2-HOUR LOCALOVERRIDE OUTSIDE OF BUSINESS HOURS.OCCUPANCY SENSORS IN THIS SPACE SHALL FUNCTION AUTO-OFF, AUTO-ON FOROCCUPANT SAFETY.PROPOSED LOCATION FOR NLIGHT AIR ANTENNA AND POWER CONNECTIONADJACENT TO ANTENNA. PROVIDE NETWORK CONNECTION FROM GATEWAY TOANTENNA. PROVIDE ANTENNA POWER SUPPLY ADAPTER AS REQUIRED.OCCUPANT SENSORS IN THIS SPACE SHALL FUNCTION AUTO-OFF, AUTO-ON TO 50%.CONTROL / DIMMING MODULE(S) FOR EXTERIOR LIGHTING ZONE. LOCATION ISPRELIMINARY PROPOSED LOCATION. CONTRACTOR TO FIELD COORDINATEMOUNTING LOCATION FOR CIRCUITING TO EXTERIOR ZONE NOTED.POWER SUPPLY LOCATIONS SHOWN ARE DIAGRAMMATIC. FIELD COORDINATEMOUNTING IN ACCESSIBLE CEILING OR IN NEAREST CASEWORK.BREAK LINES SHOWN IN ACCENT / COVE LIGHT ARE DIAGRAMMATIC. MAXIMUMLENGTH ALLOWED ON SINGLE POWER SUPPLY IS 33 FEET. FIELD COORDINATE CUTLOCATIONS AND 24V POWER SUPPLY CONNECTION LOCATIONS.VESTIBULE TO BE CONTROLLED IN SAME ZONE AS ADJACENT INTERIOR SPACE.1SCALE:1/8" = 1'-0"FIRST FLOOR LIGHTING PLAN - AREA ASHEET E-201A SHEET E-201B SHEET E-201A SHEET E-201B 234567891011 TTSC-20X18X8.62BOXML.1EKNPQ2JLW01W01W01W03W02W02W01W01C96E1R22R22R22R26R26R26b,dz1b,dz2b,dz1b,dz2Z01Z01Z01Z02Z03B20AB20AB20AB20AB20AB20AB25P04P04P04P02Z02Z02Z02B20AB20AB20AW02W02LDM1LDM1LDM1LDM1B21EW02W02B06EB06SZ01SZ01P05P05P05SZ03R22R22R24R24R24R24 R24 R24W03EOS33B20AX01666X01X01X01X03X01X01X03X03X01C96EB20AB20AB20AB20Aa2C48 7W48Eext4ext4ext5ext5ext5ext5ext5ext5ext8ext8ext8ext9ext9ext9W48ES21S21S21S21S21S21S21S21S21S21S21S21S21S21S21S21ext10ext10ext10ext10ext10ext10ext10ext10ext10ext10ext10ext10ext10ext10ext10ext10B06EB06B06EB06EB06EB06B06B06EB06EB06B06EB06R21 R21ER21R21R21ER21ER21R21R21E31LDM1SZ02ext8SZ02ext8B20AB20AZ01Z03B20AB20AB25B25B20AB20AB20AB20AB20AB20AB20AB20AB20AB20AB20AB20AB20AB20AB20ALDM11TYP Z02Z028L12EL12L12EL06L06L06L06L06AL06Aext3ext3ext3ext3ext3ext3ext3ext3ext3L07L07EL07EL07EL07EZ01D04D04D04D04W06 (TYP)W06 (TYP)W06 (TYP)W06 (TYP)W06 (TYP)W06 (TYP)L12EL12EZ05P06P06Z04Z04Z04PS1PS1PS1PS1PS1PS1PS1PS1PS1PS1PS1PS1PS1PS1PS1PS1PS1Z02PS1PS1PS2PS2PS2LDM1LDMVLDMVH12H12-1H12-1H12-1H12-1H12-1H12-1H12-1H12-1H12-1H12-1H12-1H12-1H12-1H12-1H12-1H12-1H12-1H12-1H12-1H12-1H12-1H12-1H12-1H12-1 H12-1H12-1H12-1H12-1H12-1 H12-1H12-1 H12-1 H12-1H12-1H12-1H12-1H12-1H12-1H12-1H12-1H12-1H12-1H12-1H12-1L14AL14BL14A-32L14A-32L14A-32L14A-32L14A-32W01L14A-32PS1PS1H11-7H11-7H11-7H12-1H12-1H12-1Z04S21S21S21ext10S21ext10PS1 H12-3H12-7H12-7H12-3H12-3H12-3H12-3H12-3H12-3H12-3H12-3H12-3H12-3H12-3H12-7H12-7H12-7H12-7H12-3H12-3H12-3H12-3H12-3H12-3H12-3H12-7H12-3H12-3H12-3H12-3H12-3H12-7H12-7H12-3H12-3H12-3H12-3H12-3H12-3H12-3H12-3H12-3H12-3H12-7H12-7H12-3H12-3H12-3H12-3H12-3H12-3H12-3H12-3H12-3H12-3H12-3H12-3H12-7H12-7H12-7H12-7H12-7H12-7L14A-32L14A-32L14A-32L14A-32H12-5H12-5H12-5H12-5H12-5H12-5H12-5H12-5H12-5L14A-32 L14A-32L14A-32 L14A-32H12-7H12-3H12-5H12-5L14A-32L14A-32H12-7121LOBBY122VESTIBULE123FOOD PREP128ELECTRICAL124OPEN OFFICE126SALES OFFICE125GM OFFICE127OWNER'S OFFICE132STAIR 2139GUEST CORRIDOR139BELECTRICAL130KING STUDIO134EFFICIENCY136DOUBLE QUEEN138KING STUDIOADA-M-T129EFFICIENCY131EFFICIENCY133EFFICIENCY135DOUBLE QUEEN137KING STUDIO141COURTYARDSTORAGE139AVESTIBULE121APUBLIC CORRIDORZ01H12-7ext10ext10ext3ext3ext3ext3LCM1ext3LDM1ext3ext6ext6ext6ext6LCM1LDM1ext6ext6ext7ext9ext9L16ext9aaaabcccccccdf-dz8 f-dz8f-dz8f-dz8ggghhhhhii-dz8i-dz7i-dz7i-dz7i-dz1i-dz1i-dz1 i-dz1i-dz1i-dz2i-dz2i-dz2i-dz2i-dz2iiii-dz4i-dz3i-dz4i-dz3i-dz6i-dz5ii-dz5i-dz5i-dz5i-dz6i-dz6i-dz6i-dz6jjkkkkkim-dz4m-dz3m-dz4nnnnnncacaacaacaabbbk j dLDM1LDM1bLDM1caLDM1dnnkext6LDM1kLDM1i-dz3LDM1i-dz4LDM1m-dz3LDM1m-dz4LDM1i-dz1LDM1i-dz2LDM1iLDM1i-dz7LDM1i-dz8LDM1i-dz5LDM1i-dz6LDM1hLDM1f-dz8LDMVgLDM1jLDMVppLDM1ext8ext8ext8ext8LDM1ext8LDMVext9LDM1ext9ext5LDM1ext4ext7LCM1LPAT-7LPAT-7LPAT-7LPAT-7LPAT-7H12-5H12-5H12-5H12-5H12-5H12-5H12-9H12-9H12-9H12-9H12-9H12-9H12-9H12-9H12-9L12-38H11-15H11-15H12-9H12-9H11-15H11-15ext10LCM1H12-9H12-9H12-9H12-9H12-9H12-9H12-9H12-9H12-9H12-9H12-9H12-9H12-9H11-15BRDG23444445TYP66667789TYP TYP9 10101011LDM1DLdz1dz2DLdz3dz4DLdz5dz6DLdz7dz8123E-102TYPFGH8.19781043156E1132 MERCHANT STREET, SUITE 208HONOLULU, HI 96813808-352-5299OWNER:HOMEWOOD SUITES by HILTON SPOKANE VALLEY, WA 13515 E. Carlisle Avenue Spokane Valley, WA 99216FSC PROJECT NO. 21012PERMITDOCUMENTSMay 31, 2024GL8 MirabeauPoint, LLCTMK:PID: 45101.0401 10909 E. Pierce LaneSpokane, WA 99206(509) 919-0901Revision ScheduleNumber Description Date5915 S REGAL STREETSUITE 201SPOKANE, WA 99223PH: 509.473.9218Kelly@kwrllc.comwww.kwrllc.com5/30/2024 12:50:05 PMSTATE OF WASHINGTONREGISTERED PROFESSIONAL ENG INEER48350 KELLY A N DREW WATERMAN05.31.24FIRST FLOORLIGHTING PLAN -AREA BE-201BSCALE:1/8" = 1'-0"FIRST FLOOR LIGHTING PLAN - AREA BSHEET E-201ASHEET E-201BSHEET E-201ASHEET E-201B FLAG NOTESMOUNT LIGHTING CONTROL MODULE TO JUNCTION BOX ABOVE ACCESSIBLE CEILING.CONNECT UN-SWITCHED CIRCUIT TO LINE SIDE OF MODULE AND EXTEND SWITCHEDCIRCUIT AND 0-10V DIMMING CIRCUIT TO LIGHTING ZONES INDICATED. IN AREASWITH INACCESSIBLE CEILINGS, LOCATE DEVICES IN NEAREST ADJACENT ACCESSIBLECEILING OR NON-PUBLIC UTILITY SPACE. DEVICES SHALL BE LOCATEDCONSISTENTLY FOR SIMILAR SPACES (I.E. ABOVE DOORS IN OFFICES).MOUNT BRIDGE DEVICE ABOVE ACCESSIBLE CEILING. BRIDGE TO RECEIVE HOMERUNS FROM LOCAL LIGHTING CONTROL NETWORK DAISY CHAINS IN ADJACENTAREAS. NOT ALL BRIDGES ARE SHOWN, PROVIDE BRIDGES AS REQUIRED TO ACCEPTA DEDICATED LOCAL NETWORK HOMERUN FROM EACH SPACE. REFER TOMANUFACTURER'S SHOP DRAWINGS FOR FINAL QUANTITIES.LIGHTING CONTROLS IN THIS SPACE SHALL UTILIZE TIME-BASED AUTOMATICCONTROL BASED ON BUSINESS HOURS DEFINED BY THE OWNER DURING STARTUP.LIGHTING CONTROL MODULES AND DEVICES TO BE CONNECTED TO DIGITALLIGHTING CONTROL NETWORK TO OBTAIN TIME-CLOCK SIGNAL. CONTROL STATIONSIN THIS SPACE ARE INTENDED FOR DIMMING CONTROL AND 2-HOUR LOCALOVERRIDE OUTSIDE OF BUSINESS HOURS.CONTROL / DIMMING MODULE(S) FOR EXTERIOR LIGHTING ZONE. LOCATION ISPRELIMINARY PROPOSED LOCATION. CONTRACTOR TO FIELD COORDINATEMOUNTING LOCATION FOR CIRCUITING TO EXTERIOR ZONE NOTED.POWER SUPPLY LOCATIONS SHOWN ARE DIAGRAMMATIC. FIELD COORDINATEMOUNTING IN ACCESSIBLE CEILING OR IN NEAREST CASEWORK.BREAK LINES SHOWN IN ACCENT / COVE LIGHT ARE DIAGRAMMATIC. MAXIMUMLENGTH ALLOWED ON SINGLE POWER SUPPLY IS 33 FEET. FIELD COORDINATE CUTLOCATIONS AND 24V POWER SUPPLY CONNECTION LOCATIONS.VESTIBULE TO BE CONTROLLED IN SAME ZONE AS ADJACENT INTERIOR SPACE.REFER TO ARCHITECTURAL CASEWORK, MILLWORK, COVE, AND CEILING DETAILS INTHIS SPACE FOR MOUNTING OF ALL ACCENT FIXTURES. SEE ARCHITECTURAL PLANSFOR EXACT DIMENSIONS, AND PROVIDE LENGTHS AS SHOWN.FIELD COORDINATE ROUTING OF 12V CONDUCTORS FROM INTERIOR POWER SUPPLY'PS2' TO COLUMN MOUNTED LUMINAIRE. LUMINAIRE MOUNTED IN RECESSED NOOKOF COLUMN.FIELD COORDINATE ALL POWER SUPPLY AND CONTROL MODULE DEVICES INEXTERIOR CASEWORK FOR PATIO LIGHTING ZONES. FIELD COORDINATE WITHCASEWORK, TRELLIS, AND FIREPIT MANUFACTURERS FOR CONCEALING BRANCHCIRCUITS WHERE POSSIBLE.LINEAR FIXTURE SHALL REPLACE SINGLE TRELLIS BEAM IN THIS APPROXIMATELOCATION. COORDINATE WITH TRELLIS MANUFACTURER FOR ROUGH-IN ANDINSTALLATION.GRAPHICAL CONTROL STATION FOR LOBBY AND CONNECTING CORRIDOR LIGHTINGCONTROL ZONES 'a' THROUGH 'o'. CONTROL STATION SHALL BE PASSWORDPROTECTED TO PREVENT USE BY UNAUTHORIZED PERSONNEL. PROVIDE SCENEPROGRAMMING FOR ASSOCIATED ZONES BASED UPON OWNER NEEDS, PRIOR TOPROJECT CLOSEOUT.123456789101112GENERAL NOTESA. PROVIDE UN-SWITCHED HOT CONDUCTOR TO ALL EMERGENCY LUMINAIRESAND EXIT SIGNS. EMERGENCY LUNIMAIRES ARE INDICATED BY HATCHINGAND/OR WITH AN 'E' DESIGNATION ON THE END OF FIXTURE NAME.B. PROVIDE ALL HARDWARE AND ACCESSORIES REQUIRED TO MOUNTLUMINAIRE IN LOCATIONS SHOWN INCLUDING ALL MOUNTING BRACKETS,T-BAR HANGERS, CANOPIES, ETC.C. LIGHTING CONTROLS BASIS OF DESIGN IS A DIGITAL DISTRIBUTED,NETWORKABLE SYSTEM CONSISTING OF CONTROL/DIMMING MODULES ANDBOTH MANUAL AND AUTOMATIC INPUT DEVICES (OCCUPANCY SENSORS,DAYLIGHT SENSORS, AND MANUAL CONTROL STATIONS. EACH SPACE SHALLCONSIST OF A LOCAL LIGHTING CONTROL NETWORK, WITH ALL CONTROLDEVICES IN THE SPACE CONNECTED TOGETHER VIA CAT-5E NETWORK IN ADAISY CHAIN TOPOLOGY. EACH SPACE SHALL HAVE A NETWORK HOME RUNOF CAT-5E CABLE THAT TERMINATES ON A DEDICATED BRIDGE PORT ON THENEAREST NETWORK BRIDGE. INTERIOR AND EXTERIOR LIGHTING ZONESSHALL TERMINATE ON DEDICATED NETWORK BRIDGES OR BRIDGE HUBS.ACTUAL QUANTITY OF BRIDGES NOT SHOWN AND SHALL BE DETERMINED ONMANUFACTURER'S SHOP DRAWINGS.D. ALL OCCUPANCY SENSORS SHALL BE SET TO A DEFAULT TIME DELAY OF 15MINUTES. OCCUPANCY SENSORS IN RESTROOMS AND CORRIDORS SHALL BESET TO AUTO ON, AUTO OFF. ALL OTHER OCCUPANCY SENSORS SHALL BESET TO MANUAL ON, AUTO OFF UNLESS OTHERWISE NOTED.E. EXTERIOR LIGHTING CONTROL ZONES SEQUENCE OF OPERATION ASFOLLOWS:- ext3: FULL BRIGHTNESS FROM DUSK TO DAWN, FOR OCCUPANT SAFETY.- ext4: FULL BRIGHTNESS FROM DUSK TO DAWN, FOR OCCUPANT SAFETY- ext5: FULL BRIGHTNESS FROM DUSK TO 11PM, 30% BRIGHTNESS FROM 11PM TO 6AM, FULL BRIGHTNESS FROM 6AM TO DAWN.- ext6: FULL BRIGHTNESS FROM DUSK TO 11PM, 30% BRIGHTNESS FROM 11PM TO 6AM, FULL BRIGHTNESS FROM 6AM TO DAWN.- ext7: FULL BRIGHTNESS FROM DUSK TO DAWN, FOR OCCUPANT SAFETY.- ext8: FULL BRIGHTNESS FROM DUSK TO 11PM, 30% BRIGHTNESS FROM 11PM TO 6AM, FULL BRIGHTNESS FROM 6AM TO DAWN.- ext9: FULL BRIGHTNESS FROM DUSK TO 11PM, 30% BRIGHTNESS FROM 11PM TO 6AM, FULL BRIGHTNESS FROM 6AM TO DAWN.- ext10: FULL BRIGHTNESS FROM DUSK TO DAWN, FOR OCCUPANT SAFETY.COORDINATE SCHEDULING AND BRIGHTNESS LEVELS WITH OWNER PRIORTO PROJECT CLOSEOUT. W/D W/D DNUP53.16.12.1DC.1ECCBB8.1941.1A78610W01W01B22AEB22B22AEB26B26B26B22EB06E1C48EC48C48EC48EC48C48C48EW01W01W01W01W01W012X03C48X01X03X01LDM1OSOS1LDM1C96EC96C96EOS1TYP X02B06EB06B06EB06B06EB06B06B06EB06B06EB06B06EB06B06EB06213W01W01W48EH11-13H11-13H11-13H11-13H11-13H11-13H11-13 H11-13H11-13H11-13H11-13H11-13H11-13H11-13H11-13H11-13H11-13H11-13H11-13H11-13H11-13H11-13H11-13H11-13H11-13H11-13H11-13H11-9H11-13H11-13H11-13H11-13H11-13H11-13H11-13H11-13L21-14L21-14L21-14L21-14L21-14L21-14L21-14L21-14L21-14L21-14H11-13H11-13H11-13H11-13111ELEV 1113ELEV 2217ELEVATOR LOBBY209LINENS &HOUSEKEEPING140LINEN CHUTE207ENGINEERINGOFFICE & STORAGE207APBX/MDF209APANELS206STAIR 1208EFFICIENCY205EFFICIENCY203EFFICIENCYENLARGED201KING 1-BEDROOMENLARGED202KING1-BEDROOM204KING STUDIO210DOUBLE QUEEN212DOUBLE QUEENENLARGED214KING STUDIO216KING STUDIO218KING STUDIO200CONNECTINGCORRIDOR209BIDF209CDAC201ABALCONY202ABALCONYLDM1LDMVL21215GUESTCORRIDOR242C48E C48 H11-13 H11-13 W48EH11-7E31232 MERCHANT STREET, SUITE 208HONOLULU, HI 96813808-352-5299OWNER:HOMEWOOD SUITES by HILTON SPOKANE VALLEY, WA 13515 E. Carlisle Avenue Spokane Valley, WA 99216FSC PROJECT NO. 21012PERMITDOCUMENTSMay 31, 2024GL8 MirabeauPoint, LLCTMK:PID: 45101.0401 10909 E. Pierce LaneSpokane, WA 99206(509) 919-0901Revision ScheduleNumber Description Date5915 S REGAL STREETSUITE 201SPOKANE, WA 99223PH: 509.473.9218Kelly@kwrllc.comwww.kwrllc.com5/30/2024 12:50:14 PMSTATE OF WASHINGTONREGISTERED PROFESSIONAL ENG INEER48350 KELLY A N DREW WATERMAN05.31.24SECOND FLOORLIGHTING PLAN -AREA AE-202ASCALE:1/8" = 1'-0"SECOND FLOOR LIGHTING PLAN - AREA ASHEET E-202A SHEET E-202B SHEET E-202A SHEET E-202B GENERAL NOTESA. PROVIDE UN-SWITCHED HOT CONDUCTOR TO ALL EMERGENCY LUMINAIRESAND EXIT SIGNS. EMERGENCY LUNIMAIRES ARE INDICATED BY HATCHINGAND/OR WITH AN 'E' DESIGNATION ON THE END OF FIXTURE NAME.B. PROVIDE ALL HARDWARE AND ACCESSORIES REQUIRED TO MOUNTLUMINAIRE IN LOCATIONS SHOWN INCLUDING ALL MOUNTING BRACKETS,T-BAR HANGERS, CANOPIES, ETC.C. LIGHTING CONTROLS BASIS OF DESIGN IS A DIGITAL DISTRIBUTED,NETWORKABLE SYSTEM CONSISTING OF CONTROL/DIMMING MODULES ANDBOTH MANUAL AND AUTOMATIC INPUT DEVICES (OCCUPANCY SENSORS,DAYLIGHT SENSORS, AND MANUAL CONTROL STATIONS. EACH SPACE SHALLCONSIST OF A LOCAL LIGHTING CONTROL NETWORK, WITH ALL CONTROLDEVICES IN THE SPACE CONNECTED TOGETHER VIA CAT-5E NETWORK IN ADAISY CHAIN TOPOLOGY. EACH SPACE SHALL HAVE A NETWORK HOME RUNOF CAT-5E CABLE THAT TERMINATES ON A DEDICATED BRIDGE PORT ON THENEAREST NETWORK BRIDGE. INTERIOR AND EXTERIOR LIGHTING ZONESSHALL TERMINATE ON DEDICATED NETWORK BRIDGES OR BRIDGE HUBS.ACTUAL QUANTITY OF BRIDGES NOT SHOWN AND SHALL BE DETERMINED ONMANUFACTURER'S SHOP DRAWINGS.D. ALL OCCUPANCY SENSORS SHALL BE SET TO A DEFAULT TIME DELAY OF 15MINUTES. OCCUPANCY SENSORS IN RESTROOMS AND CORRIDORS SHALL BESET TO AUTO ON, AUTO OFF. ALL OTHER OCCUPANCY SENSORS SHALL BESET TO MANUAL ON, AUTO OFF UNLESS OTHERWISE NOTED.FLAG NOTESMOUNT LIGHTING CONTROL MODULE TO JUNCTION BOX ABOVE ACCESSIBLE CEILING.CONNECT UN-SWITCHED CIRCUIT TO LINE SIDE OF MODULE AND EXTEND SWITCHEDCIRCUIT AND 0-10V DIMMING CIRCUIT TO LIGHTING ZONES INDICATED. IN AREASWITH INACCESSIBLE CEILINGS, LOCATE DEVICES IN NEAREST ADJACENT ACCESSIBLECEILING OR NON-PUBLIC UTILITY SPACE. DEVICES SHALL BE LOCATEDCONSISTENTLY FOR SIMILAR SPACES (I.E. ABOVE DOORS IN OFFICES).LIGHTING CONTROLS IN THIS SPACE SHALL UTILIZE TIME-BASED AUTOMATICCONTROL BASED ON BUSINESS HOURS DEFINED BY THE OWNER DURING STARTUP.LIGHTING CONTROL MODULES AND DEVICES TO BE CONNECTED TO DIGITALLIGHTING CONTROL NETWORK TO OBTAIN TIME-CLOCK SIGNAL.MANUAL OVERRIDE / DIMMING CONTROL STATION FOR CORRIDOR AND ELEVATORLOBBY LIGHTING THROUGHOUT THIS FLOOR.MANUAL OVERRIDE FOR STAIRWELL LOCATED ON FIRST FLOOR.1234 DNUPFGML.1EKNPQHJLW01X03X01X011X02B06B06B06EB06EB06EB06B06EB06B06EB06B06EB06B06EB06B06EB06W01W01W01W01W01W01W01W01W01W48EH11-13H11-13H11-13H11-13H11-13H12-1H11-13H11-13H11-13H11-13H11-13H11-13H11-13H11-13H11-13H11-13H11-13H11-13H11-13H11-13H11-13L21-14L21-14L21-14L21-14L21-14L21-14L21-14L21-14L21-14L21-14220KING STUDIO226KING STUDIO230KING STUDIO238KING STUDIOADA-M-T219KING STUDIO221KING STUDIO223KING STUDIO225KING STUDIO227EFFICIENCY229EFFICIENCY231EFFICIENCY233EFFICIENCY237KING STUDIO235DOUBLE QUEEN232STAIR 2228EFFICIENCY234EFFICIENCY236DOUBLE QUEEN224DOUBLE QUEEN222DOUBLE QUEEN215AELECTRICAL215GUESTCORRIDOR235ABALCONY237ABALCONY225ABALCONY223ABALCONY221ABALCONY219ABALCONY231W48EH12-156.18.1978610E1132 MERCHANT STREET, SUITE 208HONOLULU, HI 96813808-352-5299OWNER:HOMEWOOD SUITES by HILTON SPOKANE VALLEY, WA 13515 E. Carlisle Avenue Spokane Valley, WA 99216FSC PROJECT NO. 21012PERMITDOCUMENTSMay 31, 2024GL8 MirabeauPoint, LLCTMK:PID: 45101.0401 10909 E. Pierce LaneSpokane, WA 99206(509) 919-0901Revision ScheduleNumber Description Date5915 S REGAL STREETSUITE 201SPOKANE, WA 99223PH: 509.473.9218Kelly@kwrllc.comwww.kwrllc.com5/30/2024 12:50:24 PMSTATE OF WASHINGTONREGISTERED PROFESSIONAL ENG INEER48350 KELLY A N DREW WATERMAN05.31.24SECOND FLOORLIGHTING PLAN -AREA BE-202BSCALE:1/8" = 1'-0"SECOND FLOOR LIGHTING PLAN - AREA BSHEET E-202ASHEET E-202BSHEET E-202ASHEET E-202B GENERAL NOTESA. PROVIDE UN-SWITCHED HOT CONDUCTOR TO ALL EMERGENCY LUMINAIRESAND EXIT SIGNS. EMERGENCY LUNIMAIRES ARE INDICATED BY HATCHINGAND/OR WITH AN 'E' DESIGNATION ON THE END OF FIXTURE NAME.B. PROVIDE ALL HARDWARE AND ACCESSORIES REQUIRED TO MOUNTLUMINAIRE IN LOCATIONS SHOWN INCLUDING ALL MOUNTING BRACKETS,T-BAR HANGERS, CANOPIES, ETC.C. LIGHTING CONTROLS BASIS OF DESIGN IS A DIGITAL DISTRIBUTED,NETWORKABLE SYSTEM CONSISTING OF CONTROL/DIMMING MODULES ANDBOTH MANUAL AND AUTOMATIC INPUT DEVICES (OCCUPANCY SENSORS,DAYLIGHT SENSORS, AND MANUAL CONTROL STATIONS. EACH SPACE SHALLCONSIST OF A LOCAL LIGHTING CONTROL NETWORK, WITH ALL CONTROLDEVICES IN THE SPACE CONNECTED TOGETHER VIA CAT-5E NETWORK IN ADAISY CHAIN TOPOLOGY. EACH SPACE SHALL HAVE A NETWORK HOME RUNOF CAT-5E CABLE THAT TERMINATES ON A DEDICATED BRIDGE PORT ON THENEAREST NETWORK BRIDGE. INTERIOR AND EXTERIOR LIGHTING ZONESSHALL TERMINATE ON DEDICATED NETWORK BRIDGES OR BRIDGE HUBS.ACTUAL QUANTITY OF BRIDGES NOT SHOWN AND SHALL BE DETERMINED ONMANUFACTURER'S SHOP DRAWINGS.D. ALL OCCUPANCY SENSORS SHALL BE SET TO A DEFAULT TIME DELAY OF 15MINUTES. OCCUPANCY SENSORS IN RESTROOMS AND CORRIDORS SHALL BESET TO AUTO ON, AUTO OFF. ALL OTHER OCCUPANCY SENSORS SHALL BESET TO MANUAL ON, AUTO OFF UNLESS OTHERWISE NOTED.FLAG NOTESLIGHTING CONTROLS IN THIS SPACE SHALL UTILIZE TIME-BASED AUTOMATICCONTROL BASED ON BUSINESS HOURS DEFINED BY THE OWNER DURING STARTUP.LIGHTING CONTROL MODULES AND DEVICES TO BE CONNECTED TO DIGITALLIGHTING CONTROL NETWORK TO OBTAIN TIME-CLOCK SIGNAL.MANUAL OVERRIDE FOR THIS SPACE LOCATED IN HOUSEKEEPING ROOM ON THISFLOOR.MANUAL OVERRIDE FOR STAIRWELL LOCATED ON FIRST FLOOR.123 W/D DNUPW D Microwave53.16.12.1DC.1ECCBB8.1941.1A78610W48EW01W01B22AEB22B22AEB26B26B26B22EB06E1W01W01W01W01W01W012X03X01X03X01LDM1OSOS2X02B06EB06B06EB06B06EB06B06B06EB06B06EB06B06EB06B06EB062W01W01H41-5H41-5H41-5H41-5H41-5H41-5H41-5H41-5H41-5H41-5H41-5H41-5H41-5H41-5H41-5H41-5H41-5H41-5H41-5H41-5H41-5H41-5H11-9H41-5H41-5H41-5H41-5H41-5H41-5L31-8L31-8L31-8L31-8L31-8L31-8L31-8L31-8L31-8L31-8111ELEV. 1113ELEV. 2317ELEVATOR LOBBY309LINENS &HOUSEKEEPING140LINEN CHUTE307EFFICIENCY309BIDF309APANELS306STAIR 1308EFFICIENCY305EFFICIENCY303EFFICIENCYENLARGED301KING 1-BEDROOMADA-M-T302KING1-BEDROOM304KING STUDIO310DOUBLE QUEEN312DOUBLE QUEENENLARGED314KING STUDIO316KING STUDIO318KING STUDIO300CONNECTINGCORRIDOR309CDAC301ABALCONY302ABALCONY13LDM1LDMV1TYP L3142315GUEST CORRIDORC48EC48C48EC48EC48C48C48EC48H41-5H41-5H41-5H41-5H41-5H41-5H41-5H41-5W48EH11-9E31232 MERCHANT STREET, SUITE 208HONOLULU, HI 96813808-352-5299OWNER:HOMEWOOD SUITES by HILTON SPOKANE VALLEY, WA 13515 E. Carlisle Avenue Spokane Valley, WA 99216FSC PROJECT NO. 21012PERMITDOCUMENTSMay 31, 2024GL8 MirabeauPoint, LLCTMK:PID: 45101.0401 10909 E. Pierce LaneSpokane, WA 99206(509) 919-0901Revision ScheduleNumber Description Date5915 S REGAL STREETSUITE 201SPOKANE, WA 99223PH: 509.473.9218Kelly@kwrllc.comwww.kwrllc.com5/30/2024 12:50:34 PMSTATE OF WASHINGTONREGISTERED PROFESSIONAL ENG INEER48350 KELLY A N DREW WATERMAN05.31.24THIRD FLOORLIGHTING PLAN -AREA AE-203ASCALE:1/8" = 1'-0"THIRD FLOOR LIGHTING PLAN - AREA ASHEET E-203A SHEET E-203B SHEET E-203A SHEET E-203B GENERAL NOTESA. PROVIDE UN-SWITCHED HOT CONDUCTOR TO ALL EMERGENCY LUMINAIRESAND EXIT SIGNS. EMERGENCY LUNIMAIRES ARE INDICATED BY HATCHINGAND/OR WITH AN 'E' DESIGNATION ON THE END OF FIXTURE NAME.B. PROVIDE ALL HARDWARE AND ACCESSORIES REQUIRED TO MOUNTLUMINAIRE IN LOCATIONS SHOWN INCLUDING ALL MOUNTING BRACKETS,T-BAR HANGERS, CANOPIES, ETC.C. LIGHTING CONTROLS BASIS OF DESIGN IS A DIGITAL DISTRIBUTED,NETWORKABLE SYSTEM CONSISTING OF CONTROL/DIMMING MODULES ANDBOTH MANUAL AND AUTOMATIC INPUT DEVICES (OCCUPANCY SENSORS,DAYLIGHT SENSORS, AND MANUAL CONTROL STATIONS. EACH SPACE SHALLCONSIST OF A LOCAL LIGHTING CONTROL NETWORK, WITH ALL CONTROLDEVICES IN THE SPACE CONNECTED TOGETHER VIA CAT-5E NETWORK IN ADAISY CHAIN TOPOLOGY. EACH SPACE SHALL HAVE A NETWORK HOME RUNOF CAT-5E CABLE THAT TERMINATES ON A DEDICATED BRIDGE PORT ON THENEAREST NETWORK BRIDGE. INTERIOR AND EXTERIOR LIGHTING ZONESSHALL TERMINATE ON DEDICATED NETWORK BRIDGES OR BRIDGE HUBS.ACTUAL QUANTITY OF BRIDGES NOT SHOWN AND SHALL BE DETERMINED ONMANUFACTURER'S SHOP DRAWINGS.D. ALL OCCUPANCY SENSORS SHALL BE SET TO A DEFAULT TIME DELAY OF 15MINUTES. OCCUPANCY SENSORS IN RESTROOMS AND CORRIDORS SHALL BESET TO AUTO ON, AUTO OFF. ALL OTHER OCCUPANCY SENSORS SHALL BESET TO MANUAL ON, AUTO OFF UNLESS OTHERWISE NOTED.FLAG NOTESMOUNT LIGHTING CONTROL MODULE TO JUNCTION BOX ABOVE ACCESSIBLE CEILING.CONNECT UN-SWITCHED CIRCUIT TO LINE SIDE OF MODULE AND EXTEND SWITCHEDCIRCUIT AND 0-10V DIMMING CIRCUIT TO LIGHTING ZONES INDICATED. IN AREASWITH INACCESSIBLE CEILINGS, LOCATE DEVICES IN NEAREST ADJACENT ACCESSIBLECEILING OR NON-PUBLIC UTILITY SPACE. DEVICES SHALL BE LOCATEDCONSISTENTLY FOR SIMILAR SPACES (I.E. ABOVE DOORS IN OFFICES).LIGHTING CONTROLS IN THIS SPACE SHALL UTILIZE TIME-BASED AUTOMATICCONTROL BASED ON BUSINESS HOURS DEFINED BY THE OWNER DURING STARTUP.LIGHTING CONTROL MODULES AND DEVICES TO BE CONNECTED TO DIGITALLIGHTING CONTROL NETWORK TO OBTAIN TIME-CLOCK SIGNAL.MANUAL OVERRIDE / DIMMING CONTROL STATION FOR CORRIDOR AND ELEVATORLOBBY LIGHTING THROUGHOUT THIS FLOOR.MANUAL OVERRIDE FOR STAIRWELL LOCATED ON FIRST FLOOR.1234 DNUPLW48EW011X03X01X011X02B06B06B06EB06EB06EB06B06EB06B06EB06B06EB06B06EB06B06EB06W01W01W01W01W01W01W01W01W01H41-5H41-5H41-5H41-5H12-1H41-5H41-5H41-5H41-5H41-5H41-5H41-5H41-5H41-5H41-5H41-5H41-5H41-5H41-5H41-5H41-5L31-8L31-8L31-8L31-8L31-8L31-8L31-8L31-8L31-8L31-8315AELECTRICAL320KING STUDIO326KING STUDIO330KING STUDIO338KING STUDIOENLARGED319KING STUDIO321KING STUDIO323KING STUDIO325KING STUDIO327EFFICIENCY329EFFICIENCY331EFFICIENCY333EFFICIENCY337KING STUDIO335DOUBLE QUEEN332STAIR 2328EFFICIENCY334EFFICIENCY336DOUBLE QUEEN324DOUBLE QUEEN322DOUBLE QUEEN315GUEST CORRIDOR335ABALCONY337ABALCONY325ABALCONY323ABALCONY321ABALCONY319ABALCONY23W48EH12-156.18.1978610FGHML.1KNPQJE32 MERCHANT STREET, SUITE 208HONOLULU, HI 96813808-352-5299OWNER:HOMEWOOD SUITES by HILTON SPOKANE VALLEY, WA 13515 E. Carlisle Avenue Spokane Valley, WA 99216FSC PROJECT NO. 21012PERMITDOCUMENTSMay 31, 2024GL8 MirabeauPoint, LLCTMK:PID: 45101.0401 10909 E. Pierce LaneSpokane, WA 99206(509) 919-0901Revision ScheduleNumber Description Date5915 S REGAL STREETSUITE 201SPOKANE, WA 99223PH: 509.473.9218Kelly@kwrllc.comwww.kwrllc.com5/30/2024 12:50:45 PMSTATE OF WASHINGTONREGISTERED PROFESSIONAL ENG INEER48350 KELLY A N DREW WATERMAN05.31.24THIRD FLOORLIGHTING PLAN -AREA BE-203BSCALE:1/8" = 1'-0"THIRD FLOOR LIGHTING PLAN - AREA BSHEET E-203ASHEET E-203BSHEET E-203ASHEET E-203B GENERAL NOTESA. PROVIDE UN-SWITCHED HOT CONDUCTOR TO ALL EMERGENCY LUMINAIRESAND EXIT SIGNS. EMERGENCY LUNIMAIRES ARE INDICATED BY HATCHINGAND/OR WITH AN 'E' DESIGNATION ON THE END OF FIXTURE NAME.B. PROVIDE ALL HARDWARE AND ACCESSORIES REQUIRED TO MOUNTLUMINAIRE IN LOCATIONS SHOWN INCLUDING ALL MOUNTING BRACKETS,T-BAR HANGERS, CANOPIES, ETC.C. LIGHTING CONTROLS BASIS OF DESIGN IS A DIGITAL DISTRIBUTED,NETWORKABLE SYSTEM CONSISTING OF CONTROL/DIMMING MODULES ANDBOTH MANUAL AND AUTOMATIC INPUT DEVICES (OCCUPANCY SENSORS,DAYLIGHT SENSORS, AND MANUAL CONTROL STATIONS. EACH SPACE SHALLCONSIST OF A LOCAL LIGHTING CONTROL NETWORK, WITH ALL CONTROLDEVICES IN THE SPACE CONNECTED TOGETHER VIA CAT-5E NETWORK IN ADAISY CHAIN TOPOLOGY. EACH SPACE SHALL HAVE A NETWORK HOME RUNOF CAT-5E CABLE THAT TERMINATES ON A DEDICATED BRIDGE PORT ON THENEAREST NETWORK BRIDGE. INTERIOR AND EXTERIOR LIGHTING ZONESSHALL TERMINATE ON DEDICATED NETWORK BRIDGES OR BRIDGE HUBS.ACTUAL QUANTITY OF BRIDGES NOT SHOWN AND SHALL BE DETERMINED ONMANUFACTURER'S SHOP DRAWINGS.D. ALL OCCUPANCY SENSORS SHALL BE SET TO A DEFAULT TIME DELAY OF 15MINUTES. OCCUPANCY SENSORS IN RESTROOMS AND CORRIDORS SHALL BESET TO AUTO ON, AUTO OFF. ALL OTHER OCCUPANCY SENSORS SHALL BESET TO MANUAL ON, AUTO OFF UNLESS OTHERWISE NOTED.FLAG NOTESLIGHTING CONTROLS IN THIS SPACE SHALL UTILIZE TIME-BASED AUTOMATICCONTROL BASED ON BUSINESS HOURS DEFINED BY THE OWNER DURING STARTUP.LIGHTING CONTROL MODULES AND DEVICES TO BE CONNECTED TO DIGITALLIGHTING CONTROL NETWORK TO OBTAIN TIME-CLOCK SIGNAL.MANUAL OVERRIDE FOR THIS SPACE LOCATED IN HOUSEKEEPING ROOM ON THISFLOOR.MANUAL OVERRIDE FOR STAIRWELL LOCATED ON FIRST FLOOR.123 W/D W/D DNUP53.16.12.1DC.1ECCBB8.1941.1A78610W01W01B22AEB22B22AEB26B26B26B22EB06E1W01W01W01W01W01W013X03X01X03X01LDM1OSOS3X02B06EB06B06EB06B06EB06B06B06EB06B06EB06B06EB06B06EB063W01W01H41-1H41-1H41-1H41-1H41-1H41-1 H41-1H41-1H41-1H41-1H41-1H41-1H41-1H41-1H41-1H41-1H41-1H41-1H41-1H41-1H41-1H41-1H41-1H41-1H41-1H41-1H41-1H41-1L41-8L41-8L41-8L41-8L41-8L41-8L41-8L41-8L41-8L41-8W48EH11-9111ELEV. 1113ELEV. 2417ELEVATOR LOBBY409LINENS &HOUSEKEEPING140LINEN CHUTE407EFFICIENCY409APANELS406STAIR 1408EFFICIENCY405EFFICIENCY403EFFICIENCYENLARGED401KING 1-BEDROOMENLARGED402KING1-BEDROOM404KING STUDIO410DOUBLE QUEEN412DOUBLE QUEENADA-M-T414KING STUDIO416KING STUDIO418KING STUDIO400CONNECTINGCORRIDOR401ABALCONY402ABALCONY409BIDF409CDAC12LDM1LDMV1TYP H41BRDG3415GUEST CORRIDOR54C48EC48C48EC48EC48C48C48EC48H41-1H41-1H41-1H41-1H41-1H41-1H41-1H41-1W48EH11-9312E32 MERCHANT STREET, SUITE 208HONOLULU, HI 96813808-352-5299OWNER:HOMEWOOD SUITES by HILTON SPOKANE VALLEY, WA 13515 E. Carlisle Avenue Spokane Valley, WA 99216FSC PROJECT NO. 21012PERMITDOCUMENTSMay 31, 2024GL8 MirabeauPoint, LLCTMK:PID: 45101.0401 10909 E. Pierce LaneSpokane, WA 99206(509) 919-0901Revision ScheduleNumber Description Date5915 S REGAL STREETSUITE 201SPOKANE, WA 99223PH: 509.473.9218Kelly@kwrllc.comwww.kwrllc.com5/30/2024 12:50:54 PMSTATE OF WASHINGTONREGISTERED PROFESSIONAL ENG INEER48350 KELLY A N DREW WATERMAN05.31.24FOURTH FLOORLIGHTING PLAN -AREA AE-204ASCALE:1/8" = 1'-0"FOURTH FLOOR LIGHTING PLAN - AREA ASHEET E-204A SHEET E-204B SHEET E-204A SHEET E-204B GENERAL NOTESA. PROVIDE UN-SWITCHED HOT CONDUCTOR TO ALL EMERGENCY LUMINAIRESAND EXIT SIGNS. EMERGENCY LUNIMAIRES ARE INDICATED BY HATCHINGAND/OR WITH AN 'E' DESIGNATION ON THE END OF FIXTURE NAME.B. PROVIDE ALL HARDWARE AND ACCESSORIES REQUIRED TO MOUNTLUMINAIRE IN LOCATIONS SHOWN INCLUDING ALL MOUNTING BRACKETS,T-BAR HANGERS, CANOPIES, ETC.C. LIGHTING CONTROLS BASIS OF DESIGN IS A DIGITAL DISTRIBUTED,NETWORKABLE SYSTEM CONSISTING OF CONTROL/DIMMING MODULES ANDBOTH MANUAL AND AUTOMATIC INPUT DEVICES (OCCUPANCY SENSORS,DAYLIGHT SENSORS, AND MANUAL CONTROL STATIONS. EACH SPACE SHALLCONSIST OF A LOCAL LIGHTING CONTROL NETWORK, WITH ALL CONTROLDEVICES IN THE SPACE CONNECTED TOGETHER VIA CAT-5E NETWORK IN ADAISY CHAIN TOPOLOGY. EACH SPACE SHALL HAVE A NETWORK HOME RUNOF CAT-5E CABLE THAT TERMINATES ON A DEDICATED BRIDGE PORT ON THENEAREST NETWORK BRIDGE. INTERIOR AND EXTERIOR LIGHTING ZONESSHALL TERMINATE ON DEDICATED NETWORK BRIDGES OR BRIDGE HUBS.ACTUAL QUANTITY OF BRIDGES NOT SHOWN AND SHALL BE DETERMINED ONMANUFACTURER'S SHOP DRAWINGS.D. ALL OCCUPANCY SENSORS SHALL BE SET TO A DEFAULT TIME DELAY OF 15MINUTES. OCCUPANCY SENSORS IN RESTROOMS AND CORRIDORS SHALL BESET TO AUTO ON, AUTO OFF. ALL OTHER OCCUPANCY SENSORS SHALL BESET TO MANUAL ON, AUTO OFF UNLESS OTHERWISE NOTED.FLAG NOTESMOUNT LIGHTING CONTROL MODULE TO JUNCTION BOX ABOVE ACCESSIBLE CEILING.CONNECT UN-SWITCHED CIRCUIT TO LINE SIDE OF MODULE AND EXTEND SWITCHEDCIRCUIT AND 0-10V DIMMING CIRCUIT TO LIGHTING ZONES INDICATED. IN AREASWITH INACCESSIBLE CEILINGS, LOCATE DEVICES IN NEAREST ADJACENT ACCESSIBLECEILING OR NON-PUBLIC UTILITY SPACE. DEVICES SHALL BE LOCATEDCONSISTENTLY FOR SIMILAR SPACES (I.E. ABOVE DOORS IN OFFICES).MOUNT BRIDGE DEVICE ABOVE ACCESSIBLE CEILING. BRIDGE TO RECEIVE HOMERUNS FROM LOCAL LIGHTING CONTROL NETWORK DAISY CHAINS IN ADJACENTAREAS. NOT ALL BRIDGES ARE SHOWN, PROVIDE BRIDGES AS REQUIRED TO ACCEPTA DEDICATED LOCAL NETWORK HOMERUN FROM EACH SPACE. REFER TOMANUFACTURER'S SHOP DRAWINGS FOR FINAL QUANTITIES.LIGHTING CONTROLS IN THIS SPACE SHALL UTILIZE TIME-BASED AUTOMATICCONTROL BASED ON BUSINESS HOURS DEFINED BY THE OWNER DURING STARTUP.LIGHTING CONTROL MODULES AND DEVICES TO BE CONNECTED TO DIGITALLIGHTING CONTROL NETWORK TO OBTAIN TIME-CLOCK SIGNAL.MANUAL OVERRIDE / DIMMING CONTROL STATION FOR CORRIDOR AND ELEVATORLOBBY LIGHTING THROUGHOUT THIS FLOOR.MANUAL OVERRIDE FOR STAIRWELL LOCATED ON FIRST FLOOR.12345 DNUPLW011X03X01X011X02B06B06B06EB06EB06EB06B06EB06B06EB06B06EB06B06EB06B06EB06W01W01W01W01W01W01W01W01W01W48EH41-1H41-1H41-1H41-1H12-1H41-1H41-1H41-1H41-1H41-1H41-1H41-1H41-1H41-1H41-1H41-1H41-1H41-1H41-1H41-1H41-1L41-8L41-8L41-8L41-8L41-8L41-8L41-8L41-8L41-8L41-8415AELECTRICAL420KING STUDIO426KING STUDIO430KING STUDIO438KING STUDIOADA-M-RI419KING STUDIO421KING STUDIO423KING STUDIO425KING STUDIO427EFFICIENCY429EFFICIENCY431EFFICIENCY433EFFICIENCY437KING STUDIO435DOUBLE QUEEN432STAIR 2428EFFICIENCY434EFFICIENCY436DOUBLE QUEEN424DOUBLE QUEEN422DOUBLE QUEEN415GUEST CORRIDOR435ABALCONY437ABALCONY425ABALCONY423ABALCONY421ABALCONY419ABALCONY23W48EH12-156.18.1978610FGHML.1KNPQJE32 MERCHANT STREET, SUITE 208HONOLULU, HI 96813808-352-5299OWNER:HOMEWOOD SUITES by HILTON SPOKANE VALLEY, WA 13515 E. Carlisle Avenue Spokane Valley, WA 99216FSC PROJECT NO. 21012PERMITDOCUMENTSMay 31, 2024GL8 MirabeauPoint, LLCTMK:PID: 45101.0401 10909 E. Pierce LaneSpokane, WA 99206(509) 919-0901Revision ScheduleNumber Description Date5915 S REGAL STREETSUITE 201SPOKANE, WA 99223PH: 509.473.9218Kelly@kwrllc.comwww.kwrllc.com5/30/2024 12:51:05 PMSTATE OF WASHINGTONREGISTERED PROFESSIONAL ENG INEER48350 KELLY A N DREW WATERMAN05.31.24FOURTH FLOORLIGHTING PLAN -AREA BE-204BSCALE:1/8" = 1'-0"FOURTH FLOOR LIGHTING PLAN - AREA BSHEET E-204ASHEET E-204BSHEET E-204ASHEET E-204B GENERAL NOTESA. PROVIDE UN-SWITCHED HOT CONDUCTOR TO ALL EMERGENCY LUMINAIRESAND EXIT SIGNS. EMERGENCY LUNIMAIRES ARE INDICATED BY HATCHINGAND/OR WITH AN 'E' DESIGNATION ON THE END OF FIXTURE NAME.B. PROVIDE ALL HARDWARE AND ACCESSORIES REQUIRED TO MOUNTLUMINAIRE IN LOCATIONS SHOWN INCLUDING ALL MOUNTING BRACKETS,T-BAR HANGERS, CANOPIES, ETC.C. LIGHTING CONTROLS BASIS OF DESIGN IS A DIGITAL DISTRIBUTED,NETWORKABLE SYSTEM CONSISTING OF CONTROL/DIMMING MODULES ANDBOTH MANUAL AND AUTOMATIC INPUT DEVICES (OCCUPANCY SENSORS,DAYLIGHT SENSORS, AND MANUAL CONTROL STATIONS. EACH SPACE SHALLCONSIST OF A LOCAL LIGHTING CONTROL NETWORK, WITH ALL CONTROLDEVICES IN THE SPACE CONNECTED TOGETHER VIA CAT-5E NETWORK IN ADAISY CHAIN TOPOLOGY. EACH SPACE SHALL HAVE A NETWORK HOME RUNOF CAT-5E CABLE THAT TERMINATES ON A DEDICATED BRIDGE PORT ON THENEAREST NETWORK BRIDGE. INTERIOR AND EXTERIOR LIGHTING ZONESSHALL TERMINATE ON DEDICATED NETWORK BRIDGES OR BRIDGE HUBS.ACTUAL QUANTITY OF BRIDGES NOT SHOWN AND SHALL BE DETERMINED ONMANUFACTURER'S SHOP DRAWINGS.D. ALL OCCUPANCY SENSORS SHALL BE SET TO A DEFAULT TIME DELAY OF 15MINUTES. OCCUPANCY SENSORS IN RESTROOMS AND CORRIDORS SHALL BESET TO AUTO ON, AUTO OFF. ALL OTHER OCCUPANCY SENSORS SHALL BESET TO MANUAL ON, AUTO OFF UNLESS OTHERWISE NOTED.FLAG NOTESLIGHTING CONTROLS IN THIS SPACE SHALL UTILIZE TIME-BASED AUTOMATICCONTROL BASED ON BUSINESS HOURS DEFINED BY THE OWNER DURING STARTUP.LIGHTING CONTROL MODULES AND DEVICES TO BE CONNECTED TO DIGITALLIGHTING CONTROL NETWORK TO OBTAIN TIME-CLOCK SIGNAL.MANUAL OVERRIDE FOR THIS SPACE LOCATED IN HOUSEKEEPING ROOM ON THISFLOOR.MANUAL OVERRIDE FOR STAIRWELL LOCATED ON FIRST FLOOR.123 W/D W/D DN53.16.12.1DC.1ECCBB8.1941.1A78610NEMA 4XNEMA 4XG02EG02EG02EG02EW01W01B22AEB22B22AEB26B26B26B22EB06E1W01W01W01W01W01W012X03X01X03X01LDM1OSOS2X02B06EB06B06EB06B06EB06B06B06EB06B06EB06B06EB06B06EB062W01W01W48EH41-3H41-3H41-3H41-3H41-3H41-3H41-3H41-3H41-3ELEV-5ELEV-5ELEV-5ELEV-5H41-3H41-3H41-3H41-3H41-3H41-3H41-3H41-3H41-3H41-3H41-3H41-3H41-3H41-3H41-3H41-3H11-9H41-3H41-3H41-3L51-20L51-20L51-20L51-20L51-20L51-20L51-20L51-20L51-20L51-20ELEV111ELEV. 1113ELEV. 2517ELEVATOR LOBBY140LINEN CHUTE509APANELS506STAIR 1508EFFICIENCY505EFFICIENCY503EFFICIENCYADA-M-T501KING 1-BEDROOMENLARGED502KING1-BEDROOM504KING STUDIO510DOUBLE QUEEN512DOUBLE QUEENENLARGED514KING STUDIO516KING STUDIO518KING STUDIO500CONNECTINGCORRIDOR507EFFICIENCY509LINENS &HOUSEKEEPING509BIDF509CDAC501ABALCONY502ABALCONY13LDM1LDMV1TYP 2515GUEST CORRIDORL514C48EC48C48EC48EC48C48C48EC48H41-3H41-3H41-3H41-3H41-3H41-3H41-3H41-3W48EH11-95TYP.E31232 MERCHANT STREET, SUITE 208HONOLULU, HI 96813808-352-5299OWNER:HOMEWOOD SUITES by HILTON SPOKANE VALLEY, WA 13515 E. Carlisle Avenue Spokane Valley, WA 99216FSC PROJECT NO. 21012PERMITDOCUMENTSMay 31, 2024GL8 MirabeauPoint, LLCTMK:PID: 45101.0401 10909 E. Pierce LaneSpokane, WA 99206(509) 919-0901Revision ScheduleNumber Description Date5915 S REGAL STREETSUITE 201SPOKANE, WA 99223PH: 509.473.9218Kelly@kwrllc.comwww.kwrllc.com5/30/2024 12:51:14 PMSTATE OF WASHINGTONREGISTERED PROFESSIONAL ENG INEER48350 KELLY A N DREW WATERMAN05.31.24FIFTH FLOORLIGHTING PLAN -AREA AE-205ASCALE:1/8" = 1'-0"FIFTH FLOOR LIGHTING PLAN - AREA ASHEET E-205A SHEET E-205B SHEET E-205A SHEET E-205B GENERAL NOTESA. PROVIDE UN-SWITCHED HOT CONDUCTOR TO ALL EMERGENCY LUMINAIRESAND EXIT SIGNS. EMERGENCY LUNIMAIRES ARE INDICATED BY HATCHINGAND/OR WITH AN 'E' DESIGNATION ON THE END OF FIXTURE NAME.B. PROVIDE ALL HARDWARE AND ACCESSORIES REQUIRED TO MOUNTLUMINAIRE IN LOCATIONS SHOWN INCLUDING ALL MOUNTING BRACKETS,T-BAR HANGERS, CANOPIES, ETC.C. LIGHTING CONTROLS BASIS OF DESIGN IS A DIGITAL DISTRIBUTED,NETWORKABLE SYSTEM CONSISTING OF CONTROL/DIMMING MODULES ANDBOTH MANUAL AND AUTOMATIC INPUT DEVICES (OCCUPANCY SENSORS,DAYLIGHT SENSORS, AND MANUAL CONTROL STATIONS. EACH SPACE SHALLCONSIST OF A LOCAL LIGHTING CONTROL NETWORK, WITH ALL CONTROLDEVICES IN THE SPACE CONNECTED TOGETHER VIA CAT-5E NETWORK IN ADAISY CHAIN TOPOLOGY. EACH SPACE SHALL HAVE A NETWORK HOME RUNOF CAT-5E CABLE THAT TERMINATES ON A DEDICATED BRIDGE PORT ON THENEAREST NETWORK BRIDGE. INTERIOR AND EXTERIOR LIGHTING ZONESSHALL TERMINATE ON DEDICATED NETWORK BRIDGES OR BRIDGE HUBS.ACTUAL QUANTITY OF BRIDGES NOT SHOWN AND SHALL BE DETERMINED ONMANUFACTURER'S SHOP DRAWINGS.D. ALL OCCUPANCY SENSORS SHALL BE SET TO A DEFAULT TIME DELAY OF 15MINUTES. OCCUPANCY SENSORS IN RESTROOMS AND CORRIDORS SHALL BESET TO AUTO ON, AUTO OFF. ALL OTHER OCCUPANCY SENSORS SHALL BESET TO MANUAL ON, AUTO OFF UNLESS OTHERWISE NOTED.FLAG NOTESMOUNT LIGHTING CONTROL MODULE TO JUNCTION BOX ABOVE ACCESSIBLE CEILING.CONNECT UN-SWITCHED CIRCUIT TO LINE SIDE OF MODULE AND EXTEND SWITCHEDCIRCUIT AND 0-10V DIMMING CIRCUIT TO LIGHTING ZONES INDICATED. IN AREASWITH INACCESSIBLE CEILINGS, LOCATE DEVICES IN NEAREST ADJACENT ACCESSIBLECEILING OR NON-PUBLIC UTILITY SPACE. DEVICES SHALL BE LOCATEDCONSISTENTLY FOR SIMILAR SPACES (I.E. ABOVE DOORS IN OFFICES).LIGHTING CONTROLS IN THIS SPACE SHALL UTILIZE TIME-BASED AUTOMATICCONTROL BASED ON BUSINESS HOURS DEFINED BY THE OWNER DURING STARTUP.LIGHTING CONTROL MODULES AND DEVICES TO BE CONNECTED TO DIGITALLIGHTING CONTROL NETWORK TO OBTAIN TIME-CLOCK SIGNAL.MANUAL OVERRIDE / DIMMING CONTROL STATION FOR CORRIDOR AND ELEVATORLOBBY LIGHTING THROUGHOUT THIS FLOOR.MANUAL OVERRIDE FOR STAIRWELL LOCATED ON FIRST FLOOR.COORDINATE FINAL LOCATION OF LUMINAIRE(S) IN TOP OF ELEVATOR SHAFT WITHELEVATOR INSTALLER PRIOR TO ROUGH-IN.12345 DNLW011X03X01X011X02B06B06B06EB06EB06EB06B06EB06B06EB06B06EB06B06EB06B06EB06W01W01W01W01W01W01W01W01W01W48EH41-3H41-3H41-3H41-3H12-1H41-3H41-3H41-3H41-3H41-3H41-3H41-3H41-3H41-3H41-3H41-3H41-3H41-3H41-3H41-3H41-3L51-20L51-20L51-20L51-20L51-20L51-20L51-20L51-20L51-20L51-20515AELECTRICAL520KING STUDIO526KING STUDIO530KING STUDIO538KING STUDIOENLARGED519KING STUDIO521KING STUDIO523KING STUDIO525KING STUDIO527EFFICIENCY529EFFICIENCY531EFFICIENCY533EFFICIENCY537KING STUDIO535DOUBLE QUEEN532STAIR 2528EFFICIENCY534EFFICIENCY536DOUBLE QUEEN524DOUBLE QUEEN522DOUBLE QUEEN515GUEST CORRIDOR535ABALCONY537ABALCONY525ABALCONY523ABALCONY521ABALCONY519ABALCONY23W48EH12-156.18.1978610FGHML.1KNPQJE32 MERCHANT STREET, SUITE 208HONOLULU, HI 96813808-352-5299OWNER:HOMEWOOD SUITES by HILTON SPOKANE VALLEY, WA 13515 E. Carlisle Avenue Spokane Valley, WA 99216FSC PROJECT NO. 21012PERMITDOCUMENTSMay 31, 2024GL8 MirabeauPoint, LLCTMK:PID: 45101.0401 10909 E. Pierce LaneSpokane, WA 99206(509) 919-0901Revision ScheduleNumber Description Date5915 S REGAL STREETSUITE 201SPOKANE, WA 99223PH: 509.473.9218Kelly@kwrllc.comwww.kwrllc.com5/30/2024 12:51:25 PMSTATE OF WASHINGTONREGISTERED PROFESSIONAL ENG INEER48350 KELLY A N DREW WATERMAN05.31.24FIFTH FLOORLIGHTING PLAN -AREA BE-205BSCALE:1/8" = 1'-0"FIFTH FLOOR LIGHTING PLAN - AREA BSHEET E-205ASHEET E-205BSHEET E-205ASHEET E-205B GENERAL NOTESA. PROVIDE UN-SWITCHED HOT CONDUCTOR TO ALL EMERGENCY LUMINAIRESAND EXIT SIGNS. EMERGENCY LUNIMAIRES ARE INDICATED BY HATCHINGAND/OR WITH AN 'E' DESIGNATION ON THE END OF FIXTURE NAME.B. PROVIDE ALL HARDWARE AND ACCESSORIES REQUIRED TO MOUNTLUMINAIRE IN LOCATIONS SHOWN INCLUDING ALL MOUNTING BRACKETS,T-BAR HANGERS, CANOPIES, ETC.C. LIGHTING CONTROLS BASIS OF DESIGN IS A DIGITAL DISTRIBUTED,NETWORKABLE SYSTEM CONSISTING OF CONTROL/DIMMING MODULES ANDBOTH MANUAL AND AUTOMATIC INPUT DEVICES (OCCUPANCY SENSORS,DAYLIGHT SENSORS, AND MANUAL CONTROL STATIONS. EACH SPACE SHALLCONSIST OF A LOCAL LIGHTING CONTROL NETWORK, WITH ALL CONTROLDEVICES IN THE SPACE CONNECTED TOGETHER VIA CAT-5E NETWORK IN ADAISY CHAIN TOPOLOGY. EACH SPACE SHALL HAVE A NETWORK HOME RUNOF CAT-5E CABLE THAT TERMINATES ON A DEDICATED BRIDGE PORT ON THENEAREST NETWORK BRIDGE. INTERIOR AND EXTERIOR LIGHTING ZONESSHALL TERMINATE ON DEDICATED NETWORK BRIDGES OR BRIDGE HUBS.ACTUAL QUANTITY OF BRIDGES NOT SHOWN AND SHALL BE DETERMINED ONMANUFACTURER'S SHOP DRAWINGS.D. ALL OCCUPANCY SENSORS SHALL BE SET TO A DEFAULT TIME DELAY OF 15MINUTES. OCCUPANCY SENSORS IN RESTROOMS AND CORRIDORS SHALL BESET TO AUTO ON, AUTO OFF. ALL OTHER OCCUPANCY SENSORS SHALL BESET TO MANUAL ON, AUTO OFF UNLESS OTHERWISE NOTED.FLAG NOTESLIGHTING CONTROLS IN THIS SPACE SHALL UTILIZE TIME-BASED AUTOMATICCONTROL BASED ON BUSINESS HOURS DEFINED BY THE OWNER DURING STARTUP.LIGHTING CONTROL MODULES AND DEVICES TO BE CONNECTED TO DIGITALLIGHTING CONTROL NETWORK TO OBTAIN TIME-CLOCK SIGNAL.MANUAL OVERRIDE FOR THIS SPACE LOCATED IN HOUSEKEEPING ROOM ON THISFLOOR.MANUAL OVERRIDE FOR STAIRWELL LOCATED ON FIRST FLOOR.123 DNFDFDD D D DWWWWUP533.16.12.1DC.1ECCBB18.1941.1AA786101E-501TVT1T2CAHPT2USBCA+60"+60"USBUSBHPT2+60"+60"+44"USBUSBUSB+44"USBRCM +44"+44"+44"+44"HP+44"HPHPNEMA 4XNEMA 4X+80"+60"DF-1HPT21A104ELECTRICAL101POOL/SPLASHPAD102POOL RESTROOM100PUBLIC CORRIDOR108WATER HEATER& FIRE105BOH LAUNDRY107LINEN DISCHARGE& SORTING110EMPLOYEEROOM112LAUNDRYLOUNGE110AEMP RR ADA140LINEN CHUTE111ELEV 1113ELEV 2109LINEN STORAGE110BEMP RR114FITNESS116MEN'SRESTROOM115WOMEN'SRESTROOM119MEETINGSTORAGE120MEETING ROOM118GUEST STORAGE106STAIR 1117ELEVATOR LOBBY103POOL MEP+44"+44"WPWPWPWPWPWPFCU-212FCU-211FCU-213USBWPWPBCU-1T2RCM100AVESTIBULE109AHOUSEKEEPINGOFFICESSSS+60"TVT1TVT1ICE-1HPT1TVT1TVT1TVT1BIKE-1TREAD-1TREAD-2TREAD-3TREAD-4ELLIP-1ELLIP-2CA1CACACADRY-1.1DRY-1.2DRY-1.3DRY-1.4WASH-1.1WASH-1.2WASH-1.3WASH-1.4WASH-2.1WASH-2.2WASH-2.3DRY-2.1DRY-2.2DRY-2.3FCU-311FCU-214EH-11SMOKE DAMPERSMOKE DAMPER1TYP233SP-1NEMA 4XSP-2NEMA 4XWH-1WH-2WH-3FSFSTSTSFACPWH-4WS-01DHWP-1DHWP-24L11-1,3,5L11-7,9,11L11-13,15,17L11-2,4,6L11-8,10,12L11-14,16,18L11-19L11-21L11-23L11-25L11-20,22L11-24,26L11-28,30L11-32,34REF-1DW-1MW-1+44"L11-27L11-29L11-31L11-33L11-35L11-37L11-39L11-36L11-36L11-36L11-38+44"+44"L12-1L12-3L12-5L12-7L12-8L12-10L12-12L12-14L12-9,11L12-9,11L12-9,11L11-40ELEV-2ELEV-4L12-16,18L12-16,18L12-16,18L12-13L12-13HPWPWP5LPAT-8LPAT-8LPAT-8LPAT-8LPAT-8L1P-2L1P-2L12-20L12-20L12-20L12-22L12-22L12-22L12-22L12-22L12-24L12-24L12-24L12-26L12-26L12-26L12-26L12-26L12-26L12-28L12-28L12-28L12-28L12-30L12-30L12-30L12-30L12-30L12-30L12-32L12-32L12-32L12-32L12-32L12-34L12-34L12-21L12-21L12-21L12-23L12-23L12-23L12-23L12-25L12-25L12-25L12-25L12-25L12-27L12-27L12-27L12-27L12-29L12-31ELEV-1ELEV-1L12-24L12-24L12-24L1P-2105ABOH DRYER22222B6WPL12-392ESDCRXESDCRXESDCRXESDCRXSESDCRX1E-702ESDCRXMAG HOLDM7L12-41FACPL12-40E32 MERCHANT STREET, SUITE 208HONOLULU, HI 96813808-352-5299OWNER:HOMEWOOD SUITES by HILTON SPOKANE VALLEY, WA 13515 E. Carlisle Avenue Spokane Valley, WA 99216FSC PROJECT NO. 21012PERMITDOCUMENTSMay 31, 2024GL8 MirabeauPoint, LLCTMK:PID: 45101.0401 10909 E. Pierce LaneSpokane, WA 99206(509) 919-0901Revision ScheduleNumber Description Date5915 S REGAL STREETSUITE 201SPOKANE, WA 99223PH: 509.473.9218Kelly@kwrllc.comwww.kwrllc.com5/30/2024 12:51:33 PMSTATE OF WASHINGTONREGISTERED PROFESSIONAL ENG INEER48350 KELLY A N DREW WATERMAN05.31.24FIRST FLOORELECTRICAL PLAN -AREA AE-301AGENERAL NOTESA. COORDINATE WITH MECHANICAL, PRIOR TO ROUGH-IN, FOR FINAL EQUIPMENT INSTALL LOCATIONS AND CONNECTION REQUIREMENTS.B. COORDINATE RECEPTACLE MOUNTING HEIGHTS IN ALL KITCHEN ANDBREAK ROOM AREAS TO AVOID CONFLICTS WITH KITCHENEQUIPMENT, COUNTERS, BACKSPLASH, AND FURNITURE.C. LOW-VOLTAGE CABLES MAY BE RUN OPEN AIR IN ACCESSIBLECEILING SPACES ABOVE SUSPENDED ACOUSTICAL CEILING TILEGRIDS. ROUTE CABLES IN CONDUIT THROUGH INACCESSIBLECEILING AREAS (I.E. HARD LID) AND WHERE EXPOSED TOSTRUCTURE.D. MAINTAIN 36" WORKING CLEARANCE IN FRONT OF ELECTRICALPANELS PER NEC REQUIREMENTS.E. GUEST UNIT DEVICE LAYOUTS NOT SHOWN ON THIS SHEET FORCLARITY. SEE SHEET E5.02 AND E5.03 FOR ENLARGED TYPICALGUEST UNIT DEVICE LAYOUTS. SEE ARCHITECTURAL PLANS FORQUANITIES AND LOCATIONS OF TYPICAL GUEST UNIT TYPES.F. FIRE ALARM SYSTEM DEVICE LAYOUT SHOWS OWNER'S MINIMUMREQUIREMENTS. FIRE ALARM SYSTEM TO BE DESIGNED BYCERTIFIED FIRE ALARM DESIGNER AND APPROVED BY AHJ PRIOR TOORDERING AND INSTALLATION.G. SEE ARCHITECTURAL FLOOR PLANS FOR DIMENSIONED LOCATIONSOF ALL FLOOR BOXESFLAG NOTESPROVIDE RECEPTACLE CONTROL MODULE (RCM) FOR AUTOMATICTIME BASED CONTROL WITH OCCUPANCY OVERRIDES OF INDICATEDRECEPTACLES IN THIS SPACE (UNLESS OTHERWISE NOTED). LOCATEABOVE ACCESSIBLE CEILING OR AGAINST CEILING ADJACENT TOLIGHTING CONTROL MODULE. IN OPEN-TO-STRUCTURE AREAS,LOCATE DEVICES TIGHT TO CEILING STRUCTURE AND PAINT TOMATCH SURROUNDING. CONNECT RCM TO LOCAL LIGHTINGCONTROL NETWORK VIA CAT-5E NETWORK CABLE.GFCI PROTECTION PROVIDED BY CIRCUIT BREAKER. SEE PANELSCHEDULES FOR ADDITIONAL INFORMATION.PROVIDE 120V CONNECTIONS AND FIRE ALARM CONNECTION FORFIRE SMOKE DAMPERS IN MECHANICAL CHASE/DUCTWORK IN THISAPPROXIMATE LOCATION. SEE MECHANICAL PLANS FOR EXACTLOCATIONS. PROVIDE DUCT SMOKE DETECTORS AT SMOKE DAMPERLOCATIONS AS SHOWN. VERIFY CONNECTION REQUIREMENTS WITHMECHANICAL PRIOR TO ROUGH-IN.FLOW AND TAMPER SWITCHES FOR MONITORING FIRE SUPPRESSIONRISER. COORDINATE FINAL QUANTITY, 120V POWER REQUIREMENTSFOR FIRE ALARM EQUIPMENT AND SPRINKLER ALARM BELL WITHSELECTED VENDOR.POOL EQUIPMENT AND ASSOCIATED BRANCH CIRCUITING IN THISWILL BE ADDED AS PART OF A DEFERRED SUBMITTAL. PANEL L1PINTENDED AS BRANCH PANELBOARD DEDICATED TO POOLEQUIPMENT.SPRINKLER ALARM / FLOW BELL. MOUNTING LOCATION AND HEIGHTTO BE DETERMINED BY SPRINKLER INSTALLER. PROVIDE 120VBRANCH CIRCUIT AS NOTED.VERIFY EXACT CONNECTION LOCATIONS AND REQUIREMENTS WITHDOOR HARDWARE PROVIDER.1SCALE:1/8" = 1'-0"FIRST FLOOR ELECTRICAL PLAN - AREA ASHEET E-301A SHEET E-301B SHEET E-301A SHEET E-301B 234567 UPML.1EKNPQ2JL2E-501COPY-1T2T2HP1111+48"+48"DF-21T2+96"+96"USBUSBUSBT4T4T4RCMRCMRCMT4T4RCMRCMRCMFIREPLACE IGNITERFIREPLACE IGNITER11MEETING ROOM121LOBBY122VESTIBULE123FOOD PREP128ELECTRICAL124OPEN OFFICE126SALES OFFICE125GM OFFICE127OWNER'S OFFICE132STAIR 2139GUEST CORRIDOR139BELECTRICAL130KING STUDIO134EFFICIENCY136DOUBLE QUEEN138KING STUDIOADA-M-T129EFFICIENCY131EFFICIENCY133EFFICIENCY135DOUBLE QUEEN137KING STUDIO141COURTYARDSTORAGEX-SDP12SDP12L14AL14BH12WPWPWPWPWPWPWPUSBUSBDOOR MOTORDOOR MOTORL16FCU-215FCU-217WP139AVESTIBULELPATFAA121APUBLIC CORRIDORHSSSSS11CACAT211PRINT-1H11KE-56KE-29KE-30KE-60EH-12L14A-1,3L14A-1,3L14A-2L14A-4L14A-6L14A-5KE-61AKE-61CKE-61DKE-96AKE-96BKE-98LPAT-1LPAT-3LPAT-5LPAT-2LPAT-2LPAT-4LPAT-4L1KA-21L1KA-25L1KA-27L1KA-16L1KA-18L1KA-20,22L1KA-24KE-61BL1KA-23ICAVLPAT-6LPAT-6LPAT-6LPAT-6LPAT-6L12-27L12-27L12-29L12-31RCML14A-8L14A-10L14A-10L14A-12L14A-12L14A-14L14A-14L14A-16L14A-16L14A-16L14A-16L14A-16L14A-18L14A-18L14A-18L14A-18L14A-20L14A-20L14A-20L14A-7L14A-7L14A-28L14A-28L14A-28L14A-28L14A-28L14A-28L14A-9L14A-11L14A-13L14A-15L14A-17L14A-19L14A-19L14A-19L14A-19L14A-19L14A-19L14A-21L14A-21L14A-21L14A-21L14A-23L14A-23L14A-23L14A-23L14A-25L14A-25L14A-25L14A-25L14A-27L14A-27L14A-29L14A-29333E-501MOTORIZED SHADEST1CC4L12-3721TYP55MAG HOLDL14A-316EF-03NEMA 3RL1KA-38,40ESDCRXESDCRXESDCESDCRXMFGH8.19781043156E1132 MERCHANT STREET, SUITE 208HONOLULU, HI 96813808-352-5299OWNER:HOMEWOOD SUITES by HILTON SPOKANE VALLEY, WA 13515 E. Carlisle Avenue Spokane Valley, WA 99216FSC PROJECT NO. 21012PERMITDOCUMENTSMay 31, 2024GL8 MirabeauPoint, LLCTMK:PID: 45101.0401 10909 E. Pierce LaneSpokane, WA 99206(509) 919-0901Revision ScheduleNumber Description Date5915 S REGAL STREETSUITE 201SPOKANE, WA 99223PH: 509.473.9218Kelly@kwrllc.comwww.kwrllc.com5/30/2024 12:51:43 PMSTATE OF WASHINGTONREGISTERED PROFESSIONAL ENG INEER48350 KELLY A N DREW WATERMAN05.31.24FIRST FLOORELECTRICAL PLAN -AREA BE-301BFLAG NOTESSHEET E-301ASHEET E-301BSHEET E-301ASHEET E-301B GENERAL NOTESA. COORDINATE WITH MECHANICAL, PRIOR TO ROUGH-IN, FOR FINAL EQUIPMENT INSTALL LOCATIONS AND CONNECTION REQUIREMENTS.B. COORDINATE RECEPTACLE MOUNTING HEIGHTS IN ALL KITCHEN ANDBREAK ROOM AREAS TO AVOID CONFLICTS WITH KITCHENEQUIPMENT, COUNTERS, BACKSPLASH, AND FURNITURE.C. LOW-VOLTAGE CABLES MAY BE RUN OPEN AIR IN ACCESSIBLECEILING SPACES ABOVE SUSPENDED ACOUSTICAL CEILING TILEGRIDS. ROUTE CABLES IN CONDUIT THROUGH INACCESSIBLECEILING AREAS (I.E. HARD LID) AND WHERE EXPOSED TOSTRUCTURE.D. MAINTAIN 36" WORKING CLEARANCE IN FRONT OF ELECTRICALPANELS PER NEC REQUIREMENTS.E. GUEST UNIT DEVICE LAYOUTS NOT SHOWN ON THIS SHEET FORCLARITY. SEE SHEET E5.02 AND E5.03 FOR ENLARGED TYPICALGUEST UNIT DEVICE LAYOUTS. SEE ARCHITECTURAL PLANS FORQUANITIES AND LOCATIONS OF TYPICAL GUEST UNIT TYPES.F. FIRE ALARM SYSTEM DEVICE LAYOUT SHOWS OWNER'S MINIMUMREQUIREMENTS. FIRE ALARM SYSTEM TO BE DESIGNED BYCERTIFIED FIRE ALARM DESIGNER AND APPROVED BY AHJ PRIOR TOORDERING AND INSTALLATION.G. SEE ARCHITECTURAL FLOOR PLANS FOR DIMENSIONED LOCATIONSOF ALL FLOOR BOXESPROVIDE RECEPTACLE CONTROL MODULE (RCM) FOR AUTOMATICTIME BASED CONTROL WITH OCCUPANCY OVERRIDES OF INDICATEDRECEPTACLES IN THIS SPACE (UNLESS OTHERWISE NOTED). LOCATEABOVE ACCESSIBLE CEILING OR AGAINST CEILING ADJACENT TOLIGHTING CONTROL MODULE. IN OPEN-TO-STRUCTURE AREAS,LOCATE DEVICES TIGHT TO CEILING STRUCTURE AND PAINT TOMATCH SURROUNDING. CONNECT RCM TO LOCAL LIGHTINGCONTROL NETWORK VIA CAT-5E NETWORK CABLE.GFCI PROTECTION PROVIDED BY CIRCUIT BREAKER. SEE PANELSCHEDULES FOR ADDITIONAL INFORMATION.PROVIDE 120V BRANCH CIRCUIT FOR FIREPLACE IGNITER CIRCUIT.EMERGENCY POWER OFF BUTTON BEING PROVIDED AS PART OFFIREPLACE; FIELD COORDINATE EXACT CONNECTION LOCATION ANDROUTE CIRCUIT THROUGH EMERGENCY POWER OFF BUTTON.PROVIDE 120V BRANCH CIRCUIT AND DATA CONNECTION ABOVECEILING FOR POWERED SHADES ALONG WALL IN THIS LOCATION.FIELD COORDINATE WITH OWNER AND SHADES INSTALLER FOREXACT ROUGH-IN LOCATION AND CONNECTION REQUIREMENTS.PROVIDE 120V BRANCH CIRCUIT ABOVE CEILING FOR DOOR MOTOR.COORDINATE WITH DOOR INSTALLER FOR EXACT LOCATION ANDCONNECTION REQUIREMENTS. PROVIDE CONDUIT PATHWAY FROMDOOR MOTOR TO ADA PUSHBUTTON ROUGH-IN LOCATION(S) FORCONTROL CABLING BY DOOR INSTALLER.VERIFY EXACT CONNECTION LOCATIONS AND REQUIREMENTS WITHDOOR HARDWARE PROVIDER. PROVIDE CONNECTION TO FIREALARM SYSTEM FOR MAG HOLD BASED UPON SIGNAL FROMBUILDING FIRE ALARM.123456SCALE:1/8" = 1'-0"FIRST FLOOR ELECRTICAL PLAN - AREA B W/D W/D DNUP53.16.12.1DC.1ECCBB8.1941.1A78610HP111ELEV 1113ELEV 2217ELEVATOR LOBBY209LINENS &HOUSEKEEPING140LINEN CHUTE207ENGINEERINGOFFICE & STORAGE207APBX/MDF209APANELS206STAIR 1208EFFICIENCY205EFFICIENCY203EFFICIENCYENLARGED201KING 1-BEDROOMENLARGED202KING1-BEDROOM204KING STUDIO210DOUBLE QUEEN212DOUBLE QUEENENLARGED214KING STUDIO216KING STUDIO218KING STUDIO200CONNECTINGCORRIDORX-SDP2L21L22L23SDP2T2T2RCMHSSSSSSSSSSSEH-21FCU-324FCU-323FCU-322FCU-321FCU-421NEMA 3REF-02NEMA 3REF-01NEMA 3RSMOKE DAMPERSMOKE DAMPERNEMA 3RL21-1,3L21-1,3L21-1,3L21-1,3L21-1,3L21-2L21-6L21-6L21-8,10L21-12IL21-5L21-5L21-5L21-5L21-7L21-9L21-9L21-9L21-9L21-9L21-11L21-13L21-15 L21-17L21-19L21-21L21-21L21-23L21-23L21-23L21-25L21-25215GUESTCORRIDOR209BIDF209CDAC201ABALCONY202ABALCONYMAG HOLD2L21-271WPL21-29433MM6L21-9DAMPER ACTUATORDAMPER ACTUATOR55L21-12L21-1278312CU-01ACU-01BH1M-2,4,6H1M-8,10,12E32 MERCHANT STREET, SUITE 208HONOLULU, HI 96813808-352-5299OWNER:HOMEWOOD SUITES by HILTON SPOKANE VALLEY, WA 13515 E. Carlisle Avenue Spokane Valley, WA 99216FSC PROJECT NO. 21012PERMITDOCUMENTSMay 31, 2024GL8 MirabeauPoint, LLCTMK:PID: 45101.0401 10909 E. Pierce LaneSpokane, WA 99206(509) 919-0901Revision ScheduleNumber Description Date5915 S REGAL STREETSUITE 201SPOKANE, WA 99223PH: 509.473.9218Kelly@kwrllc.comwww.kwrllc.com5/30/2024 12:51:48 PMSTATE OF WASHINGTONREGISTERED PROFESSIONAL ENG INEER48350 KELLY A N DREW WATERMAN05.31.24SECOND FLOORELECTRICAL PLAN -AREA AE-302AFLAG NOTESPROVIDE RECEPTACLE CONTROL MODULE (RCM) FOR AUTOMATICTIME BASED CONTROL WITH OCCUPANCY OVERRIDES OF INDICATEDRECEPTACLES IN THIS SPACE (UNLESS OTHERWISE NOTED). LOCATEABOVE ACCESSIBLE CEILING OR AGAINST CEILING ADJACENT TOLIGHTING CONTROL MODULE. IN OPEN-TO-STRUCTURE AREAS,LOCATE DEVICES TIGHT TO CEILING STRUCTURE AND PAINT TOMATCH SURROUNDING. CONNECT RCM TO LOCAL LIGHTINGCONTROL NETWORK VIA CAT-5E NETWORK CABLE.VERIFY EXACT CONNECTION LOCATIONS AND REQUIREMENTS WITHDOOR HARDWARE PROVIDER.PROVIDE 120V CONNECTIONS AND FIRE ALARM CONNECTION FORFIRE SMOKE DAMPERS IN MECHANICAL CHASE/DUCTWORK IN THISAPPROXIMATE LOCATION. SEE MECHANICAL PLANS FOR EXACTLOCATIONS.PROVIDE HVAC EQUIPMENT MAINTENANCE RECEPTACLE PER NEC210.63. FIELD LOCATE WITHIN 25'-0" OF HVAC EQUIPMENTPROVIDE 120V CONNECTION ADJACENT TO EXHAUST FAN, FORASSOCIATED DAMPER ACTUATOR.PROVIDE (1)2"C ROUTED TO ROOF FOR FUTURE SATELLITE / ISPSERVICE CABLING. FIELD COORDINATE EXACT ROUTING.PROVIDE (3)4"C SLEEVES TO CEILING SPACE BELOW, AND (3)2"C TOIDF CLOSET ABOVE, FOR CABLE ROUTING BETWEEN FLOORS.PROVIDE (3)4"C SLEEVES ABOVE CEILING BETWEEN PBX ROOM ANDIDF CLOSET FOR CABLE ROUTING.1SCALE:1/8" = 1'-0"SECOND FLOOR ELECTRICAL PLAN - AREA ASHEET E-302A SHEET E-302B SHEET E-302A SHEET E-302B GENERAL NOTESA. COORDINATE WITH MECHANICAL, PRIOR TO ROUGH-IN, FOR FINAL EQUIPMENT INSTALL LOCATIONS AND CONNECTION REQUIREMENTS.B. COORDINATE RECEPTACLE MOUNTING HEIGHTS IN ALL KITCHEN ANDBREAK ROOM AREAS TO AVOID CONFLICTS WITH KITCHENEQUIPMENT, COUNTERS, BACKSPLASH, AND FURNITURE.C. LOW-VOLTAGE CABLES MAY BE RUN OPEN AIR IN ACCESSIBLECEILING SPACES ABOVE SUSPENDED ACOUSTICAL CEILING TILEGRIDS. ROUTE CABLES IN CONDUIT THROUGH INACCESSIBLECEILING AREAS (I.E. HARD LID) AND WHERE EXPOSED TOSTRUCTURE.D. MAINTAIN 36" WORKING CLEARANCE IN FRONT OF ELECTRICALPANELS PER NEC REQUIREMENTS.E. GUEST UNIT DEVICE LAYOUTS NOT SHOWN ON THIS SHEET FORCLARITY. SEE SHEET E5.02 AND E5.03 FOR ENLARGED TYPICALGUEST UNIT DEVICE LAYOUTS. SEE ARCHITECTURAL PLANS FORQUANITIES AND LOCATIONS OF TYPICAL GUEST UNIT TYPES.F. FIRE ALARM SYSTEM DEVICE LAYOUT SHOWS OWNER'S MINIMUMREQUIREMENTS. FIRE ALARM SYSTEM TO BE DESIGNED BYCERTIFIED FIRE ALARM DESIGNER AND APPROVED BY AHJ PRIOR TOORDERING AND INSTALLATION.G. SEE ARCHITECTURAL FLOOR PLANS FOR DIMENSIONED LOCATIONSOF ALL FLOOR BOXES2345678 DNUPFGML.1EKNPQHJL220KING STUDIO226KING STUDIO230KING STUDIO238KING STUDIOADA-M-T219KING STUDIO221KING STUDIO223KING STUDIO225KING STUDIO227EFFICIENCY229EFFICIENCY231EFFICIENCY233EFFICIENCY237KING STUDIO235DOUBLE QUEEN232STAIR 2228EFFICIENCY234EFFICIENCY236DOUBLE QUEEN224DOUBLE QUEEN222DOUBLE QUEEN215AELECTRICALL25L24SSSSSSSSEH-22FCU-326FCU-325L21-1,3L21-1,3L21-4HL21-23L21-25L21-25L21-25L21-25235ABALCONY237ABALCONY225ABALCONY223ABALCONY221ABALCONY219ABALCONY56.18.197861011E32 MERCHANT STREET, SUITE 208HONOLULU, HI 96813808-352-5299OWNER:HOMEWOOD SUITES by HILTON SPOKANE VALLEY, WA 13515 E. Carlisle Avenue Spokane Valley, WA 99216FSC PROJECT NO. 21012PERMITDOCUMENTSMay 31, 2024GL8 MirabeauPoint, LLCTMK:PID: 45101.0401 10909 E. Pierce LaneSpokane, WA 99206(509) 919-0901Revision ScheduleNumber Description Date5915 S REGAL STREETSUITE 201SPOKANE, WA 99223PH: 509.473.9218Kelly@kwrllc.comwww.kwrllc.com5/30/2024 12:51:54 PMSTATE OF WASHINGTONREGISTERED PROFESSIONAL ENG INEER48350 KELLY A N DREW WATERMAN05.31.24SECOND FLOORELECTRICAL PLAN -AREA BE-302BSCALE:1/8" = 1'-0"SECOND FLOOR ELECTRICAL PLAN - AREA BSHEET E-302ASHEET E-302BSHEET E-302ASHEET E-302B GENERAL NOTESA. COORDINATE WITH MECHANICAL, PRIOR TO ROUGH-IN, FOR FINAL EQUIPMENT INSTALL LOCATIONS AND CONNECTION REQUIREMENTS.B. COORDINATE RECEPTACLE MOUNTING HEIGHTS IN ALL KITCHEN ANDBREAK ROOM AREAS TO AVOID CONFLICTS WITH KITCHENEQUIPMENT, COUNTERS, BACKSPLASH, AND FURNITURE.C. LOW-VOLTAGE CABLES MAY BE RUN OPEN AIR IN ACCESSIBLECEILING SPACES ABOVE SUSPENDED ACOUSTICAL CEILING TILEGRIDS. ROUTE CABLES IN CONDUIT THROUGH INACCESSIBLECEILING AREAS (I.E. HARD LID) AND WHERE EXPOSED TOSTRUCTURE.D. MAINTAIN 36" WORKING CLEARANCE IN FRONT OF ELECTRICALPANELS PER NEC REQUIREMENTS.E. GUEST UNIT DEVICE LAYOUTS NOT SHOWN ON THIS SHEET FORCLARITY. SEE SHEET E5.02 AND E5.03 FOR ENLARGED TYPICALGUEST UNIT DEVICE LAYOUTS. SEE ARCHITECTURAL PLANS FORQUANITIES AND LOCATIONS OF TYPICAL GUEST UNIT TYPES.F. FIRE ALARM SYSTEM DEVICE LAYOUT SHOWS OWNER'S MINIMUMREQUIREMENTS. FIRE ALARM SYSTEM TO BE DESIGNED BYCERTIFIED FIRE ALARM DESIGNER AND APPROVED BY AHJ PRIOR TOORDERING AND INSTALLATION.G. SEE ARCHITECTURAL FLOOR PLANS FOR DIMENSIONED LOCATIONSOF ALL FLOOR BOXES W/D DNUPW D Microwave53.16.12.1DC.1ECCBB8.1941.1A78610SDP3X-SDP3L31L32L33HPSSSSSSSSSEH-31FCU-333FCU-332FCU-331SMOKE DAMPERSMOKE DAMPERBCU-2L31-1,3L31-1,3L31-1,3L31-1,3L31-2L31-6L31-6IHL31-5L31-5L31-5L31-5L31-5L31-5L31-7L31-9L31-9L31-9L31-9L31-9111ELEV. 1113ELEV. 2317ELEVATOR LOBBY309LINENS &HOUSEKEEPING140LINEN CHUTE307EFFICIENCY309BIDF309APANELS306STAIR 1308EFFICIENCY305EFFICIENCY303EFFICIENCYENLARGED301KING 1-BEDROOMADA-M-T302KING1-BEDROOM304KING STUDIO310DOUBLE QUEEN312DOUBLE QUEENENLARGED314KING STUDIO316KING STUDIO318KING STUDIO300CONNECTINGCORRIDOR309CDAC301ABALCONY302ABALCONYMAG HOLD1L31-1022MML31-93E31232 MERCHANT STREET, SUITE 208HONOLULU, HI 96813808-352-5299OWNER:HOMEWOOD SUITES by HILTON SPOKANE VALLEY, WA 13515 E. Carlisle Avenue Spokane Valley, WA 99216FSC PROJECT NO. 21012PERMITDOCUMENTSMay 31, 2024GL8 MirabeauPoint, LLCTMK:PID: 45101.0401 10909 E. Pierce LaneSpokane, WA 99206(509) 919-0901Revision ScheduleNumber Description Date5915 S REGAL STREETSUITE 201SPOKANE, WA 99223PH: 509.473.9218Kelly@kwrllc.comwww.kwrllc.com5/30/2024 12:51:58 PMSTATE OF WASHINGTONREGISTERED PROFESSIONAL ENG INEER48350 KELLY A N DREW WATERMAN05.31.24THIRD FLOORELECTRICAL PLAN -AREA AE-303AFLAG NOTESVERIFY EXACT CONNECTION LOCATIONS AND REQUIREMENTS WITHDOOR HARDWARE PROVIDER.PROVIDE 120V CONNECTIONS AND FIRE ALARM CONNECTION FORFIRE SMOKE DAMPERS IN MECHANICAL CHASE/DUCTWORK IN THISAPPROXIMATE LOCATION. SEE MECHANICAL PLANS FOR EXACTLOCATIONS.PROVIDE (3)4"C EACH INTO IDF ROOM ABOVE AND BELOW, FORCABLE ROUTING BETWEEN FLOORS.1SCALE:1/8" = 1'-0"THIRD FLOOR ELECTRICAL PLAN - AREA ASHEET E-303A SHEET E-303B SHEET E-303A SHEET E-303B GENERAL NOTESA. COORDINATE WITH MECHANICAL, PRIOR TO ROUGH-IN, FOR FINAL EQUIPMENT INSTALL LOCATIONS AND CONNECTION REQUIREMENTS.B. COORDINATE RECEPTACLE MOUNTING HEIGHTS IN ALL KITCHEN ANDBREAK ROOM AREAS TO AVOID CONFLICTS WITH KITCHENEQUIPMENT, COUNTERS, BACKSPLASH, AND FURNITURE.C. LOW-VOLTAGE CABLES MAY BE RUN OPEN AIR IN ACCESSIBLECEILING SPACES ABOVE SUSPENDED ACOUSTICAL CEILING TILEGRIDS. ROUTE CABLES IN CONDUIT THROUGH INACCESSIBLECEILING AREAS (I.E. HARD LID) AND WHERE EXPOSED TOSTRUCTURE.D. MAINTAIN 36" WORKING CLEARANCE IN FRONT OF ELECTRICALPANELS PER NEC REQUIREMENTS.E. GUEST UNIT DEVICE LAYOUTS NOT SHOWN ON THIS SHEET FORCLARITY. SEE SHEET E5.02 AND E5.03 FOR ENLARGED TYPICALGUEST UNIT DEVICE LAYOUTS. SEE ARCHITECTURAL PLANS FORQUANITIES AND LOCATIONS OF TYPICAL GUEST UNIT TYPES.F. FIRE ALARM SYSTEM DEVICE LAYOUT SHOWS OWNER'S MINIMUMREQUIREMENTS. FIRE ALARM SYSTEM TO BE DESIGNED BYCERTIFIED FIRE ALARM DESIGNER AND APPROVED BY AHJ PRIOR TOORDERING AND INSTALLATION.G. SEE ARCHITECTURAL FLOOR PLANS FOR DIMENSIONED LOCATIONSOF ALL FLOOR BOXES23 DNUPLL34L35SSSSSSSSEH-32FCU-335FCU-334L31-1,3L31-1,3L31-4HL31-11L31-11L31-11L31-11L31-11315AELECTRICAL320KING STUDIO326KING STUDIO330KING STUDIO338KING STUDIOENLARGED319KING STUDIO321KING STUDIO323KING STUDIO325KING STUDIO327EFFICIENCY329EFFICIENCY331EFFICIENCY333EFFICIENCY337KING STUDIO335DOUBLE QUEEN332STAIR 2328EFFICIENCY334EFFICIENCY336DOUBLE QUEEN324DOUBLE QUEEN322DOUBLE QUEEN339CONNECTINGCORRIDOR315GUEST CORRIDOR335ABALCONY337ABALCONY325ABALCONY323ABALCONY321ABALCONY319ABALCONY56.18.1978610FGHML.1KNPQJE32 MERCHANT STREET, SUITE 208HONOLULU, HI 96813808-352-5299OWNER:HOMEWOOD SUITES by HILTON SPOKANE VALLEY, WA 13515 E. Carlisle Avenue Spokane Valley, WA 99216FSC PROJECT NO. 21012PERMITDOCUMENTSMay 31, 2024GL8 MirabeauPoint, LLCTMK:PID: 45101.0401 10909 E. Pierce LaneSpokane, WA 99206(509) 919-0901Revision ScheduleNumber Description Date5915 S REGAL STREETSUITE 201SPOKANE, WA 99223PH: 509.473.9218Kelly@kwrllc.comwww.kwrllc.com5/30/2024 12:52:04 PMSTATE OF WASHINGTONREGISTERED PROFESSIONAL ENG INEER48350 KELLY A N DREW WATERMAN05.31.24THIRD FLOORELECTRICAL PLAN -AREA BE-303BSCALE:1/8" = 1'-0"THIRD FLOOR ELECTRICAL PLAN - AREA BSHEET E-303ASHEET E-303BSHEET E-303ASHEET E-303B GENERAL NOTESA. COORDINATE WITH MECHANICAL, PRIOR TO ROUGH-IN, FOR FINAL EQUIPMENT INSTALL LOCATIONS AND CONNECTION REQUIREMENTS.B. COORDINATE RECEPTACLE MOUNTING HEIGHTS IN ALL KITCHEN ANDBREAK ROOM AREAS TO AVOID CONFLICTS WITH KITCHENEQUIPMENT, COUNTERS, BACKSPLASH, AND FURNITURE.C. LOW-VOLTAGE CABLES MAY BE RUN OPEN AIR IN ACCESSIBLECEILING SPACES ABOVE SUSPENDED ACOUSTICAL CEILING TILEGRIDS. ROUTE CABLES IN CONDUIT THROUGH INACCESSIBLECEILING AREAS (I.E. HARD LID) AND WHERE EXPOSED TOSTRUCTURE.D. MAINTAIN 36" WORKING CLEARANCE IN FRONT OF ELECTRICALPANELS PER NEC REQUIREMENTS.E. GUEST UNIT DEVICE LAYOUTS NOT SHOWN ON THIS SHEET FORCLARITY. SEE SHEET E5.02 AND E5.03 FOR ENLARGED TYPICALGUEST UNIT DEVICE LAYOUTS. SEE ARCHITECTURAL PLANS FORQUANITIES AND LOCATIONS OF TYPICAL GUEST UNIT TYPES.F. FIRE ALARM SYSTEM DEVICE LAYOUT SHOWS OWNER'S MINIMUMREQUIREMENTS. FIRE ALARM SYSTEM TO BE DESIGNED BYCERTIFIED FIRE ALARM DESIGNER AND APPROVED BY AHJ PRIOR TOORDERING AND INSTALLATION.G. SEE ARCHITECTURAL FLOOR PLANS FOR DIMENSIONED LOCATIONSOF ALL FLOOR BOXES W/D W/D DNUP53.16.12.1DC.1ECCBB8.1941.1A78610H41SDP4X-SDP4L41L42L43111ELEV. 1113ELEV. 2417ELEVATOR LOBBY409LINENS &HOUSEKEEPING140LINEN CHUTE407EFFICIENCY409APANELS406STAIR 1408EFFICIENCY405EFFICIENCY403EFFICIENCYENLARGED401KING 1-BEDROOMENLARGED402KING1-BEDROOM404KING STUDIO410DOUBLE QUEEN412DOUBLE QUEENADA-M-T414KING STUDIO416KING STUDIO418KING STUDIO400CONNECTINGCORRIDOR415GUEST CORRIDORHPSSSSSSSSSEH-41FCU-343FCU-342FCU-341SMOKE DAMPERSMOKE DAMPERL41-1,3L41-1,3L41-1,3L41-2L41-6L41-6IHL41-5L41-5L41-5L41-5L41-5L41-5L41-7L41-9L41-9L41-9L41-9L41-9401ABALCONY402ABALCONY409BIDF409CDACMAG HOLD1L41-1022MML41-9FACPSSFACPL41-123E31232 MERCHANT STREET, SUITE 208HONOLULU, HI 96813808-352-5299OWNER:HOMEWOOD SUITES by HILTON SPOKANE VALLEY, WA 13515 E. Carlisle Avenue Spokane Valley, WA 99216FSC PROJECT NO. 21012PERMITDOCUMENTSMay 31, 2024GL8 MirabeauPoint, LLCTMK:PID: 45101.0401 10909 E. Pierce LaneSpokane, WA 99206(509) 919-0901Revision ScheduleNumber Description Date5915 S REGAL STREETSUITE 201SPOKANE, WA 99223PH: 509.473.9218Kelly@kwrllc.comwww.kwrllc.com5/30/2024 12:52:08 PMSTATE OF WASHINGTONREGISTERED PROFESSIONAL ENG INEER48350 KELLY A N DREW WATERMAN05.31.24FOURTH FLOORELECTRICAL PLAN -AREA AE-304AFLAG NOTESSCALE:1/8" = 1'-0"FOURTH FLOOR ELECTRICAL PLAN - AREA ASHEET E-304A SHEET E-304B SHEET E-304A SHEET E-304B GENERAL NOTESA. COORDINATE WITH MECHANICAL, PRIOR TO ROUGH-IN, FOR FINAL EQUIPMENT INSTALL LOCATIONS AND CONNECTION REQUIREMENTS.B. COORDINATE RECEPTACLE MOUNTING HEIGHTS IN ALL KITCHEN ANDBREAK ROOM AREAS TO AVOID CONFLICTS WITH KITCHENEQUIPMENT, COUNTERS, BACKSPLASH, AND FURNITURE.C. LOW-VOLTAGE CABLES MAY BE RUN OPEN AIR IN ACCESSIBLECEILING SPACES ABOVE SUSPENDED ACOUSTICAL CEILING TILEGRIDS. ROUTE CABLES IN CONDUIT THROUGH INACCESSIBLECEILING AREAS (I.E. HARD LID) AND WHERE EXPOSED TOSTRUCTURE.D. MAINTAIN 36" WORKING CLEARANCE IN FRONT OF ELECTRICALPANELS PER NEC REQUIREMENTS.E. GUEST UNIT DEVICE LAYOUTS NOT SHOWN ON THIS SHEET FORCLARITY. SEE SHEET E5.02 AND E5.03 FOR ENLARGED TYPICALGUEST UNIT DEVICE LAYOUTS. SEE ARCHITECTURAL PLANS FORQUANITIES AND LOCATIONS OF TYPICAL GUEST UNIT TYPES.F. FIRE ALARM SYSTEM DEVICE LAYOUT SHOWS OWNER'S MINIMUMREQUIREMENTS. FIRE ALARM SYSTEM TO BE DESIGNED BYCERTIFIED FIRE ALARM DESIGNER AND APPROVED BY AHJ PRIOR TOORDERING AND INSTALLATION.G. SEE ARCHITECTURAL FLOOR PLANS FOR DIMENSIONED LOCATIONSOF ALL FLOOR BOXESVERIFY EXACT CONNECTION LOCATIONS AND REQUIREMENTS WITHDOOR HARDWARE PROVIDER.PROVIDE 120V CONNECTIONS AND FIRE ALARM CONNECTION FORFIRE SMOKE DAMPERS IN MECHANICAL CHASE/DUCTWORK IN THISAPPROXIMATE LOCATION. SEE MECHANICAL PLANS FOR EXACTLOCATIONS.PROVIDE (3)4"C EACH INTO IDF ROOM ABOVE AND BELOW, FORCABLE ROUTING BETWEEN FLOORS.123 DNUPLL45L44415AELECTRICAL420KING STUDIO426KING STUDIO430KING STUDIO438KING STUDIOADA-M-RI419KING STUDIO421KING STUDIO423KING STUDIO425KING STUDIO427EFFICIENCY429EFFICIENCY431EFFICIENCY433EFFICIENCY437KING STUDIO435DOUBLE QUEEN432STAIR 2428EFFICIENCY434EFFICIENCY436DOUBLE QUEEN424DOUBLE QUEEN422DOUBLE QUEENSSSSSSSSEH-42FCU-345FCU-344L41-1,3L41-1,3L41-4HL41-11L41-11L41-11L41-11L41-11435ABALCONY437ABALCONY425ABALCONY423ABALCONY421ABALCONY419ABALCONY56.18.1978610FGHML.1KNPQJE32 MERCHANT STREET, SUITE 208HONOLULU, HI 96813808-352-5299OWNER:HOMEWOOD SUITES by HILTON SPOKANE VALLEY, WA 13515 E. Carlisle Avenue Spokane Valley, WA 99216FSC PROJECT NO. 21012PERMITDOCUMENTSMay 31, 2024GL8 MirabeauPoint, LLCTMK:PID: 45101.0401 10909 E. Pierce LaneSpokane, WA 99206(509) 919-0901Revision ScheduleNumber Description Date5915 S REGAL STREETSUITE 201SPOKANE, WA 99223PH: 509.473.9218Kelly@kwrllc.comwww.kwrllc.com5/30/2024 12:52:14 PMSTATE OF WASHINGTONREGISTERED PROFESSIONAL ENG INEER48350 KELLY A N DREW WATERMAN05.31.24FOURTH FLOORELECTRICAL PLAN -AREA BE-304BSCALE:1/8" = 1'-0"FOURTH FLOOR ELECTRICAL PLAN - AREA BSHEET E-304ASHEET E-304BSHEET E-304ASHEET E-304B GENERAL NOTESA. COORDINATE WITH MECHANICAL, PRIOR TO ROUGH-IN, FOR FINAL EQUIPMENT INSTALL LOCATIONS AND CONNECTION REQUIREMENTS.B. COORDINATE RECEPTACLE MOUNTING HEIGHTS IN ALL KITCHEN ANDBREAK ROOM AREAS TO AVOID CONFLICTS WITH KITCHENEQUIPMENT, COUNTERS, BACKSPLASH, AND FURNITURE.C. LOW-VOLTAGE CABLES MAY BE RUN OPEN AIR IN ACCESSIBLECEILING SPACES ABOVE SUSPENDED ACOUSTICAL CEILING TILEGRIDS. ROUTE CABLES IN CONDUIT THROUGH INACCESSIBLECEILING AREAS (I.E. HARD LID) AND WHERE EXPOSED TOSTRUCTURE.D. MAINTAIN 36" WORKING CLEARANCE IN FRONT OF ELECTRICALPANELS PER NEC REQUIREMENTS.E. GUEST UNIT DEVICE LAYOUTS NOT SHOWN ON THIS SHEET FORCLARITY. SEE SHEET E5.02 AND E5.03 FOR ENLARGED TYPICALGUEST UNIT DEVICE LAYOUTS. SEE ARCHITECTURAL PLANS FORQUANITIES AND LOCATIONS OF TYPICAL GUEST UNIT TYPES.F. FIRE ALARM SYSTEM DEVICE LAYOUT SHOWS OWNER'S MINIMUMREQUIREMENTS. FIRE ALARM SYSTEM TO BE DESIGNED BYCERTIFIED FIRE ALARM DESIGNER AND APPROVED BY AHJ PRIOR TOORDERING AND INSTALLATION.G. SEE ARCHITECTURAL FLOOR PLANS FOR DIMENSIONED LOCATIONSOF ALL FLOOR BOXES W/D W/D DN53.16.12.1DC.1ECCBB8.1941.1A78610H5MSDP5X-SDP5L51L52L53ELEV-1ELEV-2H1Y-1H1Y-2ELEVX-ELEV111ELEV. 1113ELEV. 2517ELEVATOR LOBBY140LINEN CHUTE509APANELS506STAIR 1508EFFICIENCY505EFFICIENCY503EFFICIENCYADA-M-T501KING 1-BEDROOMENLARGED502KING1-BEDROOM504KING STUDIO510DOUBLE QUEEN512DOUBLE QUEENENLARGED514KING STUDIO516KING STUDIO518KING STUDIO500CONNECTINGCORRIDOR515GUEST CORRIDORNEMA 4XNEMA 4XHPSSSSSSSSSSS507EFFICIENCYEH-51FCU-353FCU-352FCU-351SMOKE DAMPERSMOKE DAMPERFCU-500L51-1,3L51-1,3L51-1,3L51-1,3L51-2L51-6L51-6IH33J4L51-10L51-10L51-10L51-10L51-10L51-10L51-12L51-14L51-14L51-14L51-14ELEV-3ELEV-3509LINENS &HOUSEKEEPING509BIDF509CDAC501ABALCONY502ABALCONYMAG HOLDL51-22144MML51-1455R57E31232 MERCHANT STREET, SUITE 208HONOLULU, HI 96813808-352-5299OWNER:HOMEWOOD SUITES by HILTON SPOKANE VALLEY, WA 13515 E. Carlisle Avenue Spokane Valley, WA 99216FSC PROJECT NO. 21012PERMITDOCUMENTSMay 31, 2024GL8 MirabeauPoint, LLCTMK:PID: 45101.0401 10909 E. Pierce LaneSpokane, WA 99206(509) 919-0901Revision ScheduleNumber Description Date5915 S REGAL STREETSUITE 201SPOKANE, WA 99223PH: 509.473.9218Kelly@kwrllc.comwww.kwrllc.com5/30/2024 12:52:18 PMSTATE OF WASHINGTONREGISTERED PROFESSIONAL ENG INEER48350 KELLY A N DREW WATERMAN05.31.24FIFTH FLOORELECTRICAL PLAN -AREA AE-305AFLAG NOTESVERIFY EXACT CONNECTION LOCATIONS AND REQUIREMENTS WITHDOOR HARDWARE PROVIDER.FIELD COORDINATE EXACT CONNECTION LOCATIONS ANDREQUIREMENTS WITH ELEVATOR VENDOR. LOCATIONS SHOWNBASED ON PRELIMINARY COORDINATION.JUNCTION BOX FOR DATA CONNECTION TO ELEVATOR SYSTEM.ROUTE (1)1"C TO MDF/PBX ROOM, FOR TELEPHONE/DATA/SECURITYCONNECTIONS TO ELEVATOR EQUIPMENT.PROVIDE 120V CONNECTIONS AND FIRE ALARM CONNECTION FORFIRE SMOKE DAMPERS IN MECHANICAL CHASE/DUCTWORK IN THISAPPROXIMATE LOCATION. SEE MECHANICAL PLANS FOR EXACTLOCATIONS.COORDINATE LOCATION OF ELEVATOR SERVICE RECEPTACLE ANDCONNECTION TO ELEVATOR CONTROLLER DISCONNECT WITHELEVATOR INSTALLER PRIOR TO ROUGH-IN.PROVIDE RELAYS FOR FLOOR RECALL AND FIREMAN'S SERVICE.COORDINATE EXACT QUANTITY WITH ELEVATOR INSTALLER.PROVIDE (3)4"C INTO IDF ROOM BELOW, FOR CABLE ROUTINGBETWEEN FLOORS.1SCALE:1/8" = 1'-0"FIFTH FLOOR ELECTRICAL PLAN - AREA ASHEET E-305A SHEET E-305B SHEET E-305A SHEET E-305B GENERAL NOTESA. COORDINATE WITH MECHANICAL, PRIOR TO ROUGH-IN, FOR FINAL EQUIPMENT INSTALL LOCATIONS AND CONNECTION REQUIREMENTS.B. COORDINATE RECEPTACLE MOUNTING HEIGHTS IN ALL KITCHEN ANDBREAK ROOM AREAS TO AVOID CONFLICTS WITH KITCHENEQUIPMENT, COUNTERS, BACKSPLASH, AND FURNITURE.C. LOW-VOLTAGE CABLES MAY BE RUN OPEN AIR IN ACCESSIBLECEILING SPACES ABOVE SUSPENDED ACOUSTICAL CEILING TILEGRIDS. ROUTE CABLES IN CONDUIT THROUGH INACCESSIBLECEILING AREAS (I.E. HARD LID) AND WHERE EXPOSED TOSTRUCTURE.D. MAINTAIN 36" WORKING CLEARANCE IN FRONT OF ELECTRICALPANELS PER NEC REQUIREMENTS.E. GUEST UNIT DEVICE LAYOUTS NOT SHOWN ON THIS SHEET FORCLARITY. SEE SHEET E5.02 AND E5.03 FOR ENLARGED TYPICALGUEST UNIT DEVICE LAYOUTS. SEE ARCHITECTURAL PLANS FORQUANITIES AND LOCATIONS OF TYPICAL GUEST UNIT TYPES.F. FIRE ALARM SYSTEM DEVICE LAYOUT SHOWS OWNER'S MINIMUMREQUIREMENTS. FIRE ALARM SYSTEM TO BE DESIGNED BYCERTIFIED FIRE ALARM DESIGNER AND APPROVED BY AHJ PRIOR TOORDERING AND INSTALLATION.G. SEE ARCHITECTURAL FLOOR PLANS FOR DIMENSIONED LOCATIONSOF ALL FLOOR BOXES234567 DNLL55L54515AELECTRICAL520KING STUDIO526KING STUDIO530KING STUDIO538KING STUDIOENLARGED519KING STUDIO521KING STUDIO523KING STUDIO525KING STUDIO527EFFICIENCY529EFFICIENCY531EFFICIENCY533EFFICIENCY537KING STUDIO535DOUBLE QUEEN532STAIR 2528EFFICIENCY534EFFICIENCY536DOUBLE QUEEN524DOUBLE QUEEN522DOUBLE QUEENSSSSSSSSEH-52FCU-355FCU-354L51-1,3L51-1,3L51-4HBUILDING MOUNTED SIGNAGELCM112L51-16L51-16L51-16L51-16L51-16L51-18535ABALCONY537ABALCONY525ABALCONY523ABALCONY521ABALCONY519ABALCONY56.18.1978610FGHML.1KNPQJE32 MERCHANT STREET, SUITE 208HONOLULU, HI 96813808-352-5299OWNER:HOMEWOOD SUITES by HILTON SPOKANE VALLEY, WA 13515 E. Carlisle Avenue Spokane Valley, WA 99216FSC PROJECT NO. 21012PERMITDOCUMENTSMay 31, 2024GL8 MirabeauPoint, LLCTMK:PID: 45101.0401 10909 E. Pierce LaneSpokane, WA 99206(509) 919-0901Revision ScheduleNumber Description Date5915 S REGAL STREETSUITE 201SPOKANE, WA 99223PH: 509.473.9218Kelly@kwrllc.comwww.kwrllc.com5/30/2024 12:52:24 PMSTATE OF WASHINGTONREGISTERED PROFESSIONAL ENG INEER48350 KELLY A N DREW WATERMAN05.31.24FIFTH FLOORELECTRICAL PLAN -AREA BE-305BFLAG NOTESPROVIDE CONTROL MODULE ABOVE ACCESSIBLE CEILING IN GUESTCORRIDOR FOR CONTROL OF BUILDING SIGNAGE CIRCUIT. MODULESHALL BE CONTROLLED VIA TIMECLOCK, INTEGRAL TO NETWORKLIGHTING CONTROL SYSTEM.PROVIDE 120V CONNECTION FOR BUILDING MOUNTED SIGNAGE. SEEARCHITECTURAL ELEVATIONS FOR EXACT HEIGHT.1SCALE:1/8" = 1'-0"FIFTH FLOOR ELECTRICAL PLAN - AREA BSHEET E-305ASHEET E-305BSHEET E-305ASHEET E-305B GENERAL NOTESA. COORDINATE WITH MECHANICAL, PRIOR TO ROUGH-IN, FOR FINAL EQUIPMENT INSTALL LOCATIONS AND CONNECTION REQUIREMENTS.B. COORDINATE RECEPTACLE MOUNTING HEIGHTS IN ALL KITCHEN ANDBREAK ROOM AREAS TO AVOID CONFLICTS WITH KITCHENEQUIPMENT, COUNTERS, BACKSPLASH, AND FURNITURE.C. LOW-VOLTAGE CABLES MAY BE RUN OPEN AIR IN ACCESSIBLECEILING SPACES ABOVE SUSPENDED ACOUSTICAL CEILING TILEGRIDS. ROUTE CABLES IN CONDUIT THROUGH INACCESSIBLECEILING AREAS (I.E. HARD LID) AND WHERE EXPOSED TOSTRUCTURE.D. MAINTAIN 36" WORKING CLEARANCE IN FRONT OF ELECTRICALPANELS PER NEC REQUIREMENTS.E. GUEST UNIT DEVICE LAYOUTS NOT SHOWN ON THIS SHEET FORCLARITY. SEE SHEET E5.02 AND E5.03 FOR ENLARGED TYPICALGUEST UNIT DEVICE LAYOUTS. SEE ARCHITECTURAL PLANS FORQUANITIES AND LOCATIONS OF TYPICAL GUEST UNIT TYPES.F. FIRE ALARM SYSTEM DEVICE LAYOUT SHOWS OWNER'S MINIMUMREQUIREMENTS. FIRE ALARM SYSTEM TO BE DESIGNED BYCERTIFIED FIRE ALARM DESIGNER AND APPROVED BY AHJ PRIOR TOORDERING AND INSTALLATION.G. SEE ARCHITECTURAL FLOOR PLANS FOR DIMENSIONED LOCATIONSOF ALL FLOOR BOXES2 533.16.12.1DC.1LML.1ECCBB1118.1941.1AKNPQ278610HJCU-03ANEMA 3RERV-01NEMA 3RCU-04NEMA 3RCU-05CU-02ANEMA 3RCU-02BNEMA 3RCU-03BNEMA 3RNEMA 3RH5M-1,3,5H5M-7,9,11H5M-2,4,6H5M-8,10,12L51-5,7,9L51-11,13,15H5M-13,15,17WPWPWPWP1TYP S2L51-8L51-8L51-8L51-8KE-7.2NEMA 3RL51-17,193432 MERCHANT STREET, SUITE 208HONOLULU, HI 96813808-352-5299OWNER:HOMEWOOD SUITES by HILTON SPOKANE VALLEY, WA 13515 E. Carlisle Avenue Spokane Valley, WA 99216FSC PROJECT NO. 21012PERMITDOCUMENTSMay 31, 2024GL8 MirabeauPoint, LLCTMK:PID: 45101.0401 10909 E. Pierce LaneSpokane, WA 99206(509) 919-0901Revision ScheduleNumber Description Date5915 S REGAL STREETSUITE 201SPOKANE, WA 99223PH: 509.473.9218Kelly@kwrllc.comwww.kwrllc.com5/30/2024 12:52:26 PMSTATE OF WASHINGTONREGISTERED PROFESSIONAL ENG INEER48350 KELLY A N DREW WATERMAN05.31.24OVERALL ELECTRICALROOF PLANE-306GENERAL NOTESFLAG NOTESPROVIDE HVAC EQUIPMENT MAINTENANCE RECEPTACLE PER NEC210.63. FIELD LOCATE WITHIN 25'-0" OF ROOF MOUNTED HVACEQUIPMENT. PROVIDE STRUT MOUNTING HARDWARE AS REQUIRED.DUCT SMOKE DETECTOR LOCATION SHOWN FOR REFERENCE.COORDINATE WITH OWNER SELECTED FIRE ALARM VENDOR FORRACEWAY REQUIREMENTS.COOLER COMPRESSOR LOCATION SHOWN IS PRELIMINARY. VERIFYFINAL LOCATION WITH COOLER PACKAGE PROVIDER PRIOR TOROUGH-IN.2"C ROUTED FROM PBX TO ROOFTOP FOR FUTURE SATELLITE ISPCABLING BY OWNER SELECTED VENDOR. STUB CONDUIT UPTHROUGH ROOF AND CAP FOR FUTURE USE. LOCATION SHOWN ISAPPROXIMATE.1SCALE:3/32" = 1'-0"OVERALL ELECTRICAL ROOF PLANA. SEE ARCHITECTURAL PLANS, SECTION, AND ELEVATIONS FOR EXACTEQUIPMENT AND DEVICE LOCATIONS.B. SEE ARCHITECTURAL PLANS FOR LOCATIONS OF SOUND, SMOKE,AND FIRE RATED WALLS.C. COORDINATE WITH MECHANICAL, PRIOR TO ROUGH-IN, FOR FINALEQUIPMENT INSTALL LOCATIONS AND CONNECTION REQUIREMENTS.D. MAINTAIN 36" WORKING CLEARANCE IN FRONT OF ELECTRICALPANELS PER NEC REQUIREMENTS.234 TSC-20X18X8.62BOX123FOOD PREPFCU-216KE-22AKE-22BKE-26L14A-1,3KE-41KE-49AKE-49BKE-47KE-48KE-42AKE-42BKE-7KE-7.1NEMA 4XKE-2KE-2.1KE-2.2KE-50KE-31KE-20T2+44"+44"JHT109-WALK-IN COOLER111L1KA-1L1KA-3L1KA-5L1KA-7L1KA-9L1KA-11L1KB-1L1KB-5L1KB-2,4L1KB-8,10L1KB-14,16L1KA-2L1KA-4,6,8L1KA-10,12,14L1KA-13,15L1KA-17L1KA-19L1KB-9,117612L1KA-26H-1H-1.1L1KA-28L1KA-302338J5L1KA-37GAS SOLENOIDL1KB-15MAU-01L1KA-32,34,36L1KAL1KBMAG HOLDML14A-3120103POOL MEPAHU-01DH-01HSUH-01L11L12L1PEVL12-6L12-2,4H1M-1,3,515L12-3517L13SDP11H11H1M104ELECTRICALAHU-01DH-01HSL11L12L1PEVMSBX-SDP11ATS-YH1YT1T1GTWYL12-6H1M-1,3,5LCM1LCM11413L12-33L12-35L12-35L12-35L13T1183D2121LOBBYT2T2T2IVRCMRCMRCMSWEET SHOPSIGNAGECASEWORKLIGHTINGCONNECTIONKE-89KE-85KE-84L1KA-29L1KA-31,33L1KA-35L14A-22L14A-22L14A-24L14A-24L14A-26L14A-26L14A-30L14A-3016ICSIV19H832 MERCHANT STREET, SUITE 208HONOLULU, HI 96813808-352-5299OWNER:HOMEWOOD SUITES by HILTON SPOKANE VALLEY, WA 13515 E. Carlisle Avenue Spokane Valley, WA 99216FSC PROJECT NO. 21012PERMITDOCUMENTSMay 31, 2024GL8 MirabeauPoint, LLCTMK:PID: 45101.0401 10909 E. Pierce LaneSpokane, WA 99206(509) 919-0901Revision ScheduleNumber Description Date5915 S REGAL STREETSUITE 201SPOKANE, WA 99223PH: 509.473.9218Kelly@kwrllc.comwww.kwrllc.com5/30/2024 12:52:37 PMSTATE OF WASHINGTONREGISTERED PROFESSIONAL ENG INEER48350 KELLY A N DREW WATERMAN05.31.24ENLARGEDELECTRICAL PLANSE-501GENERAL NOTESFLAG NOTESCIRCUITS FOR COOKING EQUIPMENT UNDER RANGE HOOD TO BEDE-ENERGIZED UPON ACTIVATION OF FIRE ALARM SYSTEM;DE-ENERGIZED VIA ANSUL SYSTEM. SEE PANEL SCHEDULES FORADDITIONAL INFORMATION.PROVIDE 3/4"C FROM ANSUL HOOD CONTROL PANEL TO PANEL FORSHUNT TRIP CONTROL WIRING.PROVIDE POWER CIRCUIT FOR ANSUL SYSTEM INDICATED ONDRAWINGS. COORDINATE ALL ADDITIONAL CONNECTIONREQUIREMENTS WITH HOOD PROVIDER PRIOR TO ROUGH IN.PROVIDE CONNECTION FROM HOOD ANSUL PANEL SUPPRESSIONSYSTEM TO BUILDING FIRE ALARM SYSTEM PER REQUIREMENTS OFNFPA 96. PROVIDE RACEWAY AND LOW VOLTAGE CONTROL WIRINGFOR HOOD ASSEMBLY PER MANUFACTURER'S SHOP DRAWINGS.PROVIDE 1/2" CONDUIT FROM HOOD CONTROL PANEL TO GASSOLENOID VALVE. PROVIDE LOW VOLTAGE CABLING FOR GAS SHUTOFF VALVE WHEN THE FIRE ALARM GOES INTO ALARM STATE.COORDINATE FINAL LOCATIONS WITH MANUFACTURER ANDMECHANICAL DRAWINGS.COORDINATE WITH KITCHEN EQUIPMENT PROVIDER AND CASEWORKPROVIDER FOR BRANCH CIRCUIT ROUTING AND ROUGH INLOCATIONS.MANUAL PULL STATION FOR ANSUL SYSTEM. PROVIDE CONNECTIONBETWEEN DEVICE AND ANSUL CONTROL PANEL AND FIRE ALARM /FIRE SUPPRESSION SYSTEM AS INDICATED ON SHOP DRAWINGS.PROVIDE RACEWAY AND LOW VOLTAGE CONTROL WIRING FORHOOD ASSEMBLY PER MANUFACTURER'S SHOP DRAWINGS.PROVIDE 120V CIRCUIT FOR HEAT TAPE IN REFRIGERATIONCONDENSATE LINE. COORDINATE WORK WITH REFRIGERATIONCONTRACTOR INSTALLING THE DRAIN LINE PRIOR TO ROUGH-IN.PROVIDE GFP PROTECTION AT CIRCUIT BREAKER PER HEAT TAPEMANUFACTURER'S INSTRUCTIONS.CONTRACTOR TO WIRE AND INSTALL LIGHT SWITCH DEVICEPROVIDED WITH COOLER PACKAGE. COORDINATE EXACT LOCATIONAND REQUIREMENTS WITH EQUIPMENT SUPPLIER.PROVIDE 'EYS' FITTINGS AND LISTED SEALING METHOD FORCONDUCTORS, RACEWAYS, OR SLEEVES ENTERING TH WALK-INCOOLER PER NEC 300.7(A). COORDINATE LOCATIONS WITH WALK-INCOOLER MANUFACTURER.CONNECTION LOCATIONS SHOWN BASED OFF OF PRELIMINARYKITCHEN LAYOUT PROVIDED BY OWNER SELECTED VENDOR.COORDINATE ALL EQUIPMENT LOCATIONS, CONNECTIONREQUIREMENTS, ROUGH-IN HEIGHTS, COOLER SEALINGREQUIREMENTS, ETC WITH KITCHEN EQUIPMENT PROVIDER PRIORTO ROUGH-IN.CONTROL MODULES FOR (2) SITE SIGNAGE BRANCH CIRCUITS, L12-15AND L12-19. ROUTE BRANCH CIRCUITS THROUGH CONTROLMODULES FOR TIMECLOCK CONTROL VIA NETWORK LIGHTINGCONTROL SYSTEM.WALL SPACE RESERVED FOR FUTURE EV CHARGING BRANCHPANELS PER WAC 429.5, AND SOLAR INVERTER, COMBINER, ANDDISCONNECTING EQUIPMENT BY OWNER SELECTED SOLARINSTALLER.POOL EQUIPMENT AND ASSOCIATED BRANCH CIRCUITING IN THISWILL BE ADDED AS PART OF A DEFERRED SUBMITTAL. PANEL L1PINTENDED AS BRANCH PANELBOARD DEDICATED TO POOLEQUIPMENT.PROVIDE 120V CIRCUIT TO SWEET SHOP SIGNAGE MOUNTED TOFRONT OF SOFFIT ABOVE.UTILIZE LIQUIDTIGHT METALLIC FLEXIBLE CONDUIT, ANDNON-CORROSIVE FITTINGS/BOXES/DEVICES IN THIS SPACE.PROVIDE 4" HIGH, 4" OFFSET HOUSE-KEEPING PAD FOR ELECTRICALEQUIPMENT INDICATED. COORDINATE FINAL REQUIREMENTS WITHSTRUCTURAL.COORDINATE CONNECTIONS AND MOUNTING LOCATIONS WITHCASEWORK PROVIDER.VERIFY EXACT CONNECTION LOCATIONS AND REQUIREMENTS WITHDOOR HARDWARE PROVIDER.1A. COORDINATE WITH MECHANICAL, PRIOR TO ROUGH-IN, FOR FINAL EQUIPMENT INSTALL LOCATIONS AND CONNECTION REQUIREMENTS.B. COORDINATE RECEPTACLE MOUNTING HEIGHTS IN ALL KITCHEN ANDBREAK ROOM AREAS TO AVOID CONFLICTS WITH KITCHENEQUIPMENT, COUNTERS, BACKSPLASH, AND FURNITURE.C. LOW-VOLTAGE CABLES MAY BE RUN OPEN AIR IN ACCESSIBLECEILING SPACES ABOVE SUSPENDED ACOUSTICAL CEILING TILEGRIDS. ROUTE CABLES IN CONDUIT THROUGH INACCESSIBLECEILING AREAS (I.E. HARD LID) AND WHERE EXPOSED TOSTRUCTURE.D. MAINTAIN 36" WORKING CLEARANCE IN FRONT OF ELECTRICALPANELS PER NEC REQUIREMENTS.E. FIRE ALARM SYSTEM DEVICE LAYOUT SHOWS OWNER'S MINIMUMREQUIREMENTS. FIRE ALARM SYSTEM TO BE DESIGNED BYCERTIFIED FIRE ALARM DESIGNER AND APPROVED BY AHJ PRIOR TOORDERING AND INSTALLATION.F. REFER TO ARCHITECTURAL PLANS FOR DEVICE MOUNTING HEIGHTSAND DIMENSIONED LOCATIONS.G. COORDINATE ALL CONNECTION MOUNTING HEIGHTS ANDREQUIREMENTS WITH KITCHEN VENDOR PRIOR TO ROUGH-IN.SCALE:1POOL MEP AND MAIN ELECTRICAL ROOM ELECTRICAL PLAN1/4" = 1'-0"SCALE:2FOOD PREP ROOM ELECTRICAL PLAN1/4" = 1'-0"23456789101112131415SCALE:3ENLARGED RECEPTION AND SWEET SHOP ELECTRICAL PLAN1/4" = 1'-0"1617181920 T1GTVWAPWAPJREFDWUSBGDMW/HOODCOOK-2G.B06G.B06G.B06G.B06G.Z24G.B06M1423VANITY LIT MIRRORAPTAC-01A-6A-6A-6A-6A-6A-6A-6A-1,3A-5,7A-2A-2A-9A-4A-8A-8A-8A-8A-8A-8A-8A-105S/C55G.Z24A-6dbcaaabaacddGTVWAPT11M4REFCOOK-2DWMW/HOODGDJ2G.P01G.P01G.B06G.B06G.B06G.B06G.B06G.B06USB3VANITY LIT MIRRORBPTAC-01B-1,3B-5,7B-9B-2B-2B-4B-6B-6B-6 B-6B-6B-6B-6B-6B-6B-8B-8B-8B-8B-8B-8B-105S/C5G.Z24G.Z24B-6B-6aedcacebebaaaadbREFCOOK-2DWMWGDM14HOOD3VANITY LIT MIRRORG.B06G.B06G.B06GTVWAPT1USBG.B06G.B06G.B06G.Z24J2CPTAC-01C-1,3C-11C-5,7C-9C-2C-2C-4C-6C-6C-6C-6C-6C-6C-6C-6C-8C-8C-8C-8C-8C-8C-8C-1055S/CG.Z24C-6acbaaaaabbbcGTVWAPT11REFCOOK-2DWMWGDJ2G.P01G.P01G.B06G.B06G.B06USB3M4HOODG.B06G.B06G.B06VANITY LIT MIRRORDPTAC-01D-1,3D-5,7D-9D-11D-2D-2D-4D-6D-6D-6D-6D-6D-6D-6D-6D-6D-8D-8D-8D-8D-8D-8D-8D-105S/C5G.Z24G.Z24D-6D-6aaacbdcdccabaabG.W01WPB-9B-6732 MERCHANT STREET, SUITE 208HONOLULU, HI 96813808-352-5299OWNER:HOMEWOOD SUITES by HILTON SPOKANE VALLEY, WA 13515 E. Carlisle Avenue Spokane Valley, WA 99216FSC PROJECT NO. 21012PERMITDOCUMENTSMay 31, 2024GL8 MirabeauPoint, LLCTMK:PID: 45101.0401 10909 E. Pierce LaneSpokane, WA 99206(509) 919-0901Revision ScheduleNumber Description Date5915 S REGAL STREETSUITE 201SPOKANE, WA 99223PH: 509.473.9218Kelly@kwrllc.comwww.kwrllc.com5/30/2024 12:52:43 PMSTATE OF WASHINGTONREGISTERED PROFESSIONAL ENG INEER48350 KELLY A N DREW WATERMAN05.31.24ENLARGEDELECTRICAL PLANSE-502GENERAL NOTESFLAG NOTESDOORBELL AND DOORBELL CONTROL SWITCH IN COMMUNICATIONFEATURE ROOMS ONLY. SEE ARCHITECTURAL PLANS FORCOMMUNICATION FEATURE ROOM LOCATIONS.THERMOSTAT LOCATION (THERMOSTAT BY OTHERS). PROVIDECONDUIT PATHWAY FROM VTAC TO THERMOSTAT AS REQUIRED.COORDINATE WITH MECHANICAL FOR EXACT REQUIREMENTS.PROVIDE 120V CONNECTION FOR INTERNALLY LIT VANITY MIRROR.COORDINATE WITH FIXTURE PROVIDER FOR ROUGH-INREQUIREMENTS. LIT MIRROR PROVIDED AS PART OF FURNITUREPACKAGE, SHALL BE INSTALLED BY ELECTRICAL CONTRACTOR.MASTER CONTROL SWITCH FOR CONTROL OF ALL PERMANENTLYINSTALLED LIGHT FIXTURES AND SWITCHED RECEPTACLES WITHINGUEST UNIT (AS REQUIRED BY WSEC 405.2.5). SEE LIGHTINGCONTROL DEVICE SCHEDULE FOR ADDITIONAL INFORMATION.FIRE HORN IN STANDARD ROOMS; PROVIDE FIRE HORN/STROBE INCOMMUNICATION FEATURE ROOMS. SEE ARCHITECTURAL PLANSFOR FEATURE ROOM LOCATIONS.1A. PROVIDE ALL HARDWARE AND ACCESSORIES REQUIRED TO MOUNTLUMINAIRE IN LOCATIONS SHOWN INCLUDING ALL MOUNTINGBRACKETS, T-BAR HANGERS, CANOPIES, ETC.B. COORDINATE WITH MECHANICAL, PRIOR TO ROUGH-IN, FOR FINALEQUIPMENT INSTALL LOCATIONS AND CONNECTION REQUIREMENTS.C. LOW-VOLTAGE CABLES MAY BE RUN OPEN AIR IN ACCESSIBLECEILING SPACES ABOVE SUSPENDED ACOUSTICAL CEILING TILEGRIDS. ROUTE CABLES IN CONDUIT THROUGH INACCESSIBLECEILING AREAS (I.E. HARD LID) AND WHERE EXPOSED TOSTRUCTURE.D. REFER TO ARCHITECTURAL PLANS FOR DEVICE MOUNTING HEIGHTSAND DIMENSIONED LOCATIONS.E. ALL RECEPTACLES IN GUEST UNITS SHALL BE TAMPER-RESISTANTTYPE.F. FIRE ALARM SYSTEM DEVICE LAYOUT SHOWS OWNER'S MINIMUMREQUIREMENTS. FIRE ALARM SYSTEM TO BE DESIGNED BYCERTIFIED FIRE ALARM DESIGNER AND APPROVED BY AHJ PRIOR TOORDERING AND INSTALLATION.G. ALL 120V, SINGLE PHASE, 20AMP BRANCH CIRCUITS SUPPLYINGOUTLETS OR DEVICES IN GUEST UNITS SHALL BE PROTECTED BY ANARC-FAULT CIRCUIT INTERRUPTER (AFCI) CIRCUIT BREAKER. SEEPANEL SCHEDULES FOR ADDITIONAL INFORMATION.H. GUEST UNIT LIGHTING CONTROLS ARE A MIX OF NETWORKEDCONTROLS INTEGRATED WITH HILTON CONNECTED ROOMS, ASWELL AS STANDALONE LINE VOLTAGE ROCKER SWITCHES. BASIS OFDESIGN AS FOLLOWS: MASTER SWITCH, AND SWITCHESCONTROLLING OVERHEAD LIGHTS AND UNDERCAB LIGHTS, AREOWNER FURNISHED, CONTRACTOR INSTALLED. SWITCHESCONTROLLING LIT VANITIES, AND PATIO SCONCES, ARE INTENDEDTO BE STANDALONE ROCKER SWITCHES, FURNISHED ANDINSTALLED BY CONTRACTOR. FOR CIRCUITING, MASTER SWITCHSHALL BE WIRED 'UPSTREAM' OF ALL OTHER SWITCHES. ALL OTHERSWITCHES SHALL BE CIRCUITED DIRECTLY 'DOWNSTREAM' OFMASTER SWITCH (I.E., NO OTHER SWITCHES CIRCUITED 'IN SERIES').VERIFY FINAL DESIGN AND PROCUREMENT INTENT WITH OWNERAND CONNECTED CONTROLS VENDOR PRIOR TO ROUGH-IN ANDORDERING OF CONTROL.SCALE:1ENLARGED ELECTRICAL PLAN - EFFICIENCY SUITE1/4" = 1'-0"SCALE:2ENLARGED ELECTRICAL PLAN - KING STUDIO1/4" = 1'-0"SCALE:4ENLARGED ELECTRICAL PLAN - ACCESSIBLE EFFICIENCY SUITE1/4" = 1'-0"SCALE:5ENLARGED ELECTRICAL PLAN - ACCESSIBLE KING STUDIO1/4" = 1'-0"2345SCALE:3ENLARGED ELECTRICAL PLAN - KING STUDIO BALCONY1/4" = 1'-0" ALIGNGTVWAPUSBT1J31M4G.P01G.P01REFCOOK-2DWMW/HOODGDG.B06G.B06G.B06G.B06G.B06G.B06VANITY LIT MIRRORFPTAC-01F-1,3F-5,7F-9F-2F-2F-4F-6F-6F-6F-6F-6F-6F-6F-6F-8F-8F-8F-8F-8F-8F-8F-8F-10F-6255G.Z24G.Z24F-6F-6S/CabaaabbaadcdeceeVANITY LIT MIRRORG.B06G.B06G.B06MOTORIZED SHADESMREFCOOK-2DWMWGDHOODT1USBGTVWAPJG.P01G.P01G.B06G.B06G.B06HPTAC-01H-1,3H-5,7H-9H-11H-2H-2H-4H-6H-6H-6H-6H-6H-6H-6 H-6H-6H-8H-8H-8H-8H-12H-12H-12H-12H-8H-8H-10S/C3412556G.Z24G.Z24H-6H-6dcdbaaaacccbbaaW/D GR-901GR-902GR-900G.P01G.P01G.B06G.B06G.B06G.B06G.B06G.B06G.F01J2GTVT1WAPVANITY LIT MIRROR14REFCOOK-4DWMW/HOODGDWASHDRYMOTORIZED SHADESGTVWAPUSBG.B06EPTAC-01PTAC-01E-1,3E-5,7E-9E-2E-2E-4E-6E-6E-6E-6E-6E-6E-6E-6E-6E-6E-6E-8E-8E-8E-8E-15E-15E-15E-10E-11,13E-12,14E-16E-15S/CSS/C5G.Z24G.Z24E-6E-6G.B06E-6M6535aaaggbbbbbccbcdefffdeG.W01WPE-15E-67W DG.F01WASHDRYREFCOOK-4DWMWGDG.P01G.B06G.B06G.B06J2T1GTVWAP3VANITY LIT MIRRORM14MOTORIZED SHADES6MOTORIZED SHADES6HOODG.B06G.B06G.B06GTVWAPUSBGPTAC-01PTAC-01G-1,3G-5,7G-9G-11G-2G-2G-4G-6G-6G-6G-6G-6G-6G-6G-6G-6G-17G-8G-8G-8G-17G-17G-17G-8G-8G-8G-17G-10G-13,15G-12,14G-165S55S/CS/CG.P01G.Z24G.Z24G-6G-6G-6G.B06G.B06G-6G-6edeaaadddbbbbbbcc cffG.W01WPG-17G-67G.W01WPF-11F-6732 MERCHANT STREET, SUITE 208HONOLULU, HI 96813808-352-5299OWNER:HOMEWOOD SUITES by HILTON SPOKANE VALLEY, WA 13515 E. Carlisle Avenue Spokane Valley, WA 99216FSC PROJECT NO. 21012PERMITDOCUMENTSMay 31, 2024GL8 MirabeauPoint, LLCTMK:PID: 45101.0401 10909 E. Pierce LaneSpokane, WA 99206(509) 919-0901Revision ScheduleNumber Description Date5915 S REGAL STREETSUITE 201SPOKANE, WA 99223PH: 509.473.9218Kelly@kwrllc.comwww.kwrllc.com5/30/2024 12:52:48 PMSTATE OF WASHINGTONREGISTERED PROFESSIONAL ENG INEER48350 KELLY A N DREW WATERMAN05.31.24ENLARGEDELECTRICAL PLANSE-503FLAG NOTESSCALE:2ENLARGED ELECTRICAL PLAN - DOUBLE QUEEN STUDIO1/4" = 1'-0"SCALE:5ENLARGED ELECTRICAL PLAN - ACCESSIBLE DOUBLE QUEEN STUDIO1/4" = 1'-0"SCALE:1ENLARGED ELECTRICAL PLAN - KING 1-BEDROOM1/4" = 1'-0"SCALE:4ENLARGED ELECTRICAL PLAN - ACCESSIBLE KING 1-BEDROOM1/4" = 1'-0"DOORBELL AND DOORBELL CONTROL SWITCH IN COMMUNICATIONFEATURE ROOMS ONLY. SEE ARCHITECTURAL PLANS FORCOMMUNICATION FEATURE ROOM LOCATIONS.THERMOSTAT LOCATION (THERMOSTAT BY OTHERS). PROVIDECONDUIT PATHWAY FROM VTAC TO THERMOSTAT AS REQUIRED.COORDINATE WITH MECHANICAL FOR EXACT REQUIREMENTS.PROVIDE 120V CONNECTION FOR INTERNALLY LIT VANITY MIRROR.COORDINATE WITH FIXTURE PROVIDER FOR ROUGH-INREQUIREMENTS. LIT MIRROR PROVIDED AS PART OF FURNITUREPACKAGE, SHALL BE INSTALLED BY ELECTRICAL CONTRACTOR.MASTER CONTROL SWITCH FOR CONTROL OF ALL PERMANENTLYINSTALLED LIGHT FIXTURES AND SWITCHED RECEPTACLES WITHINGUEST UNIT (AS REQUIRED BY WSEC 405.2.5). SEE LIGHTINGCONTROL DEVICE SCHEDULE FOR ADDITIONAL INFORMATION.FIRE HORN IN STANDARD ROOMS; PROVIDE FIRE HORN/STROBE INCOMMUNICATION FEATURE ROOMS. SEE ARCHITECTURAL PLANSFOR FEATURE ROOM LOCATIONS.PROVIDE MOTORIZED SHADE POWER CONNECTION AND PATHWAYTO CONTROL STATION. COORDINATE WITH EQUIPMENT PROVIDERFOR ROUGH-IN REQUIREMENTS.BALCONY DEVICES SHALL BE INSTALLED ON UNITS WITH BALCONIESWHERE SHOWN ON OVERALL FLOOR PLANS. SEE ARCHITECTURALROOM SUMMARIES FOR UNITS WITH BALCONIES.123456SCALE:3ENLARGED ELECTRICAL PLAN - DOUBLE QUEEN BALCONY1/4" = 1'-0"7GENERAL NOTESA. PROVIDE ALL HARDWARE AND ACCESSORIES REQUIRED TO MOUNTLUMINAIRE IN LOCATIONS SHOWN INCLUDING ALL MOUNTINGBRACKETS, T-BAR HANGERS, CANOPIES, ETC.B. COORDINATE WITH MECHANICAL, PRIOR TO ROUGH-IN, FOR FINALEQUIPMENT INSTALL LOCATIONS AND CONNECTION REQUIREMENTS.C. LOW-VOLTAGE CABLES MAY BE RUN OPEN AIR IN ACCESSIBLECEILING SPACES ABOVE SUSPENDED ACOUSTICAL CEILING TILEGRIDS. ROUTE CABLES IN CONDUIT THROUGH INACCESSIBLECEILING AREAS (I.E. HARD LID) AND WHERE EXPOSED TOSTRUCTURE.D. REFER TO ARCHITECTURAL PLANS FOR DEVICE MOUNTING HEIGHTSAND DIMENSIONED LOCATIONS.E. ALL RECEPTACLES IN GUEST UNITS SHALL BE TAMPER-RESISTANTTYPE.F. FIRE ALARM SYSTEM DEVICE LAYOUT SHOWS OWNER'S MINIMUMREQUIREMENTS. FIRE ALARM SYSTEM TO BE DESIGNED BYCERTIFIED FIRE ALARM DESIGNER AND APPROVED BY AHJ PRIOR TOORDERING AND INSTALLATION.G. ALL 120V, SINGLE PHASE, 20AMP BRANCH CIRCUITS SUPPLYINGOUTLETS OR DEVICES IN GUEST UNITS SHALL BE PROTECTED BY ANARC-FAULT CIRCUIT INTERRUPTER (AFCI) CIRCUIT BREAKER. SEEPANEL SCHEDULES FOR ADDITIONAL INFORMATION.H. GUEST UNIT LIGHTING CONTROLS ARE A MIX OF NETWORKEDCONTROLS INTEGRATED WITH HILTON CONNECTED ROOMS, ASWELL AS STANDALONE LINE VOLTAGE ROCKER SWITCHES. BASIS OFDESIGN AS FOLLOWS: MASTER SWITCH, AND SWITCHESCONTROLLING OVERHEAD LIGHTS AND UNDERCAB LIGHTS, AREOWNER FURNISHED, CONTRACTOR INSTALLED. SWITCHESCONTROLLING LIT VANITIES, AND PATIO SCONCES, ARE INTENDEDTO BE STANDALONE ROCKER SWITCHES, FURNISHED ANDINSTALLED BY CONTRACTOR. FOR CIRCUITING, MASTER SWITCHSHALL BE WIRED 'UPSTREAM' OF ALL OTHER SWITCHES. ALL OTHERSWITCHES SHALL BE CIRCUITED DIRECTLY 'DOWNSTREAM' OFMASTER SWITCH (I.E., NO OTHER SWITCHES CIRCUITED 'IN SERIES').VERIFY FINAL DESIGN AND PROCUREMENT INTENT WITH OWNERAND CONNECTED CONTROLS VENDOR PRIOR TO ROUGH-IN ANDORDERING OF CONTROL. DN2104ELECTRICAL101POOL/SPLASHPAD102POOL RESTROOM103POOL MEP27.633.6 34.5 29.9 23.135.4 44.8 46.5 39.3 29.241.453.254.445.0 33.436.7 41.6 47.0 51.3 56.9 55.9 46.4 34.744.749.8 48.8 52.0 57.0 55.8 45.9 34.038.6 43.944.147.351.750.441.430.927.7 33.5 35.5 38.0 40.5 39.2 32.9 25.324.9 31.2 32.6 31.5 25.038.3 49.0 49.4 49.5 38.738.4 48.9 49.0 49.9 38.324.7 30.9 18.322.521.7 23.3 25.3 27.0 28.5 30.1 31.5 32.5 32.7 32.1 30.0 26.525.8 27.7 29.6 31.1 32.5 33.9 35.2 36.1 36.5 36.1 34.7 31.730.0 31.9 33.8 34.7 35.5 36.4 37.2 37.9 38.5 38.5 38.1 37.0 34.4 31.0 26.134.6 36.6 38.0 38.0 37.7 37.6 37.8 38.5 39.3 40.0 40.7 41.0 40.7 38.9 38.341.440.6 39.6 36.9 33.0 28.638.7 40.7 41.6 41.0 39.8 38.8 38.3 38.6 39.3 40.6 42.1 43.4 44.244.4 44.544.143.6 41.8 38.4 34.7 30.042.3 44.044.743.4 41.2 39.4 38.4 38.3 39.0 40.8 42.9 45.0 46.6 47.6 48.2 48.5 48.0 46.2 42.7 37.1 32.741.3 46.2 46.544.541.739.3 37.9 37.7 38.7 40.7 43.4 45.9 48.0 49.5 50.3 50.6 50.2 48.6 45.3 39.7 34.637.9 43.947.447.144.9 41.9 39.3 37.6 37.3 38.3 40.5 43.4 46.2 48.6 50.3 51.2 51.6 51.3 49.9 47.3 42.6 38.843.1 46.3 48.4 47.8 45.2 42.0 39.2 37.4 36.9 38.0 40.4 43.3 46.3 48.8 50.651.552.051.750.4 48.2 45.0 42.3 39.0 36.8 36.1 36.5 36.8 36.3 34.9 31.245.147.8 49.6 48.545.542.1 39.2 37.2 36.7 37.9 40.3 43.4 46.6 49.2 50.9 51.9 52.3 51.9 50.7 48.6 45.9 43.7 41.3 40.0 39.8 40.1 40.3 40.1 38.0 36.446.5 49.0 50.5 49.1 46.0 42.3 39.2 37.2 36.9 38.0 40.3 43.6 46.9 49.6 51.3 52.3 52.6 52.2 51.0 48.9 46.3 44.2 42.8 42.4 42.6 43.2 44.0 43.7 42.1 39.847.449.8 51.2 49.8 46.5 42.5 39.3 37.4 37.1 38.2 40.7 44.0 47.3 50.0 51.8 52.7 53.0 52.6 51.2 49.0 46.4 44.2 42.9 42.8 43.4 44.6 45.9 46.5 45.0 42.447.6 50.051.449.9 46.6 42.6 39.3 37.5 37.1 38.3 41.044.4 47.750.4 52.0 52.9 53.2 52.7 51.3 49.1 46.544.142.8 42.7 43.6 45.2 46.947.746.3 43.847.149.5 51.0 49.6 46.4 42.6 39.4 37.5 37.2 38.5 41.3 44.6 47.9 50.5 52.2 52.9 53.1 52.651.148.9 46.3 44.0 42.6 42.4 43.345.146.8 47.8 46.5 44.346.2 48.7 50.3 49.0 45.9 42.3 39.4 37.6 37.5 39.0 41.644.748.0 50.7 52.2 52.9 53.1 52.4 50.9 48.7 46.2 43.8 42.3 42.1 42.9 44.6 46.3 47.2 46.144.145.147.549.1 48.045.1 41.739.0 37.6 37.7 39.2 41.945.148.4 50.9 52.4 53.1 53.2 52.4 51.0 48.7 46.2 43.6 42.1 41.8 42.4 43.945.546.445.143.243.2 45.6 47.3 46.5 44.0 41.0 38.6 37.5 37.6 39.3 42.3 45.6 48.851.152.4 53.0 52.9 52.2 50.8 48.6 45.9 43.5 41.941.441.8 43.044.445.143.7 41.940.5 42.944.744.2 42.2 39.6 37.6 36.8 37.2 39.0 42.145.548.6 50.8 51.8 52.1 52.0 51.2 49.8 47.8 45.2 43.041.540.7 40.941.742.6 43.1 41.6 39.837.2 39.541.441.2 39.6 37.6 36.1 35.5 36.3 38.2 41.244.447.3 49.2 50.0 50.2 50.0 49.2 47.8 46.1 43.9 41.9 40.4 39.5 39.4 39.7 40.2 40.3 38.6 37.032.8 35.0 36.9 36.9 35.8 34.5 33.5 33.3 34.1 36.0 38.741.744.3 45.8 46.4 46.4 46.1 45.3 44.2 42.7 40.9 39.2 37.9 37.1 36.8 36.7 36.8 36.3 34.4 33.328.4 30.2 32.0 32.4 31.7 30.8 30.1 30.1 30.9 32.7 35.1 37.7 39.8 41.041.5 41.441.0 40.4 39.5 38.3 36.8 35.4 34.3 33.6 33.2 32.8 32.6 31.8 30.3 29.6Calculation SummaryLabelUnitsAvgMaxMinAvg/MinMax/MinMEP_WorkplaneFc41.5057.023.11.802.47POOL_FloorFc43.7858.824.11.822.44RR_WorkplaneFc36.3749.918.31.992.73POOL1_SURFACEFc43.7252.136.41.201.43POOL2_SURFACEFc45.1849.939.21.151.2732 MERCHANT STREET, SUITE 208HONOLULU, HI 96813808-352-5299OWNER:HOMEWOOD SUITES by HILTON SPOKANE VALLEY, WA 13515 E. Carlisle Avenue Spokane Valley, WA 99216FSC PROJECT NO. 21012PERMITDOCUMENTSMay 31, 2024GL8 MirabeauPoint, LLCTMK:PID: 45101.0401 10909 E. Pierce LaneSpokane, WA 99206(509) 919-0901Revision ScheduleNumber Description Date5915 S REGAL STREETSUITE 201SPOKANE, WA 99223PH: 509.473.9218Kelly@kwrllc.comwww.kwrllc.com5/30/2024 12:52:55 PMSTATE OF WASHINGTONREGISTERED PROFESSIONAL ENG INEER48350 KELLY A N DREW WATERMAN05.31.24ENLARGED POOLPHOTOMETRIC PLANE-504GENERAL NOTESSCALE:1ENLARGED POOL PHOTOMETRIC PLAN1/4" = 1'-0"A. PHOTOMETRIC PLANS ARE NOT FOR CONSTRUCTION, AND INCLUDEDFOR REVIEW PURPOSES AND REFERENCE ONLY.B. LIGHTING CALCULATIONS PERFORMED IN THE CURRENT VERSIONOF LIGHTING ANALYSTS AGI32 SOFTWARE, LICENSED FOR USE BYKWR, LLC.C. CALCULATION POINTS ARE LAID OUT IN A 2'X2' GRID AT FINISHEDFLOOR LEVEL. CALCULATION UNITS ARE IN FOOT-CANDLES (FC). DISTRIBUTION PANEL 'SDP12'208Y/120V 3P 4W22,000 AIC600A BUS 600/3LSITO EXISTINGPRIMARYJUNCTIONENCLOSUREFIRST FLOOR FIRST FLOOR SECOND FLOOR SECOND FLOORMSERVICE POINTMAIN SWITCHBOARD 'MSB'480Y/277V 3P 4W42,000 AICSERVICE ENTRANCE RATED2500A BUS 2000/3LSIGSUSENEW UTILITY TRANSFORMER480Y/277V 3P 4W SECONDARYXFMR 'X-SDP11'300KVAP: 480V 3P 3W DELTAS: 208Y/120V 3P 4W WYEDISTRIBUTION PANEL 'SDP11'208Y/120V 3P 4W42,000 AIC800A BUS 800/3LSI400/3(2)2"C, 3#250KCMIL(AL), #3GLSI300/33"C, 3#500KCMIL(AL), #2GXFMR 'X-SDP12'225KVAP: 480V 3P 3W DELTAS: 208Y/120V 3P 4W WYE200A, 208Y/120V 3P 4WPANEL 'L11'200A, 208Y/120V 3P 4WPANEL 'L12'200A, 208Y/120V 3P 4WPANEL 'L13'225A, 208Y/120V 3P 4WPANEL 'L1P'100A, 208Y/120V 3P 4WPANEL 'LPAT'600A, 208Y/120V 3P 4WPANEL 'EV'200A, 208Y/120V 3P 4WPANEL 'L14A'200A, 208Y/120V 3P 4WPANEL 'L14B'400A, 208Y/120V 3P 4WPANEL 'L1KA'400A, 208Y/120V 3P 4WPANEL 'L1KB'200/32-1/2"C, 4#250KCMIL(AL), #6G200/32-1/2"C, 4#250KCMIL(AL), #6G200/32-1/2"C, 4#250KCMIL(AL), #6G225/33"C, 4#300KCMIL(AL), #4G100/31-1/2"C, 4#1, #6G600/3(2)3-1/2"C, 4#500KCMIL(AL), #1GLSI200/32-1/2"C, 4#250KCMIL(AL), #6G400/3(2)2-1/2"C, 4#250KCMIL(AL), #3GLSI100A, 480Y/277V 3P 4WPANEL 'H11'100A, 480Y/277V 3P 4WPANEL 'H12'200A, 480Y/277V 3P 4WPANEL 'H1M'100/31-1/2"C, 4#1, #6G100/31-1/2"C, 4#1, #6G200/32-1/2"C, 4#250KCMIL(AL), #6GXFMR 'X-SDP2'225KVAP: 480V 3P 3W DELTAS: 208Y/120V 3P 4W WYEGFP100/31-1/2"C, 4#1, #6G400/3(2)3"C, 4#350KCMIL(AL), #2GLSI300/3(2)3"C, 3#250KCMIL(AL), #3GLSI300/3(2)3"C, 3#250KCMIL(AL), #3GLSI300/3(2)3"C, 3#250KCMIL(AL), #3GLSIDISTRIBUTION PANEL 'SDP2'208Y/120V 3P 4W42,000 AIC600A BUS 600/3LSI(2)4"C, 4#500KCMIL(AL),#2/0G100A, 208Y/120V 3P 4WPANEL 'L21'TO TRANSFORMER'X-SDP3'TO TRANSFORMER'X-SDP4'TO TRANSFORMER'X-SDP5'TO PANEL 'H41'TO PANEL 'H5M'TO ELEVATOR'ELEV-1'100/31-1/2"C, 4#1, #6GDISTRIBUTION PANEL 'H1Y'480Y/277V 3P 4W22,000 AIC150A BUS GENERATOR 'GEN-Y'LEGALLY REQUIRED STANDBY (NEC 701)480Y/277V 3P 4W100KW,125KVAAUTOMATIC TRANSFERSWITCH 'ATS-Y'480Y/277V 3P 4W150A, 4-POLEBYPASS-ISOLATIONCONTACTORSTO ELEVATOR'ELEV-2'(3)4"C, 4#400KCMIL(AL), #3/0G(2)4"C, 4#500KCMIL(AL), #2/0G2"C, 4#3/0(AL), #6G1"C & CONTROL CABLE TO ATSGENERATORANNUNCIATOR1"C TO ANNUNCIATOR:CABLING PERMANUFACTUREREPOCONTROLS2"C, 4#3/0(AL), #6G150A FRAME150A FUSEMMMMMMMMMMMM300/3(2)3"C, 3#250KCMIL(AL), #3GLSITO TRANSFORMER'X-ELEV'1423765910111213#3/013#3/013#2/0141460/3SPD1560/3SPD1560/3SPD1560/3SPD1560/3SPD15MM30/33/4"C, 3#10, #10G1430/33/4"C, 4#8, #8G150/32"C, 4#3/0(AL), #6G30/33/4"C, 4#8, #8G200/3200/3200/3TO PANEL 'L23', SUBFEEDING(6) 100A PANELS AND (1) 125APANELTO PANEL 'L24', SUBFEEDING(8) 100A PANELSTO PANEL 'L25', SUBFEEDING(7) 100A PANELS2-1/2"C, 4#250KCMIL(AL), #6GPANEL 'L22'208Y/120V 3P 4W200A,200/32-1/2"C, 4#250KCMIL(AL), #6G125A, 208/120V 2P 3WGUEST UNIT 202 PANEL100A, 208/120V 2P 3WGUEST UNIT 204 PANEL125/23#1/0, #6G100/23#2, #8G16PANEL 'L16'208Y/120V 3P 4W200A,16200/32-1/2"C, 4#250KCMIL(AL), #6G100A, 208/120V 2P 3WGUEST UNIT 129 PANEL100/23#2, #8G60A, 208Y/120V 3P 4WPANEL 'LSS'60/360/31-1/4"C, 4#4, #8G17181860/3TO SOLAR INVERTEREQUIPMENT(BY SOLAR VENDOR)SYSTEM CAPACITY:153.64KW200/34E-7014E-7013"C, 4#350KCMIL(AL), #4G3"C, 4#350KCMIL(AL), #4G5E-701(6)4"C, 4#600KCMIL(AL)1916TYP(3)2"CFAULT CURRENTSCHEDULEDEVICEFAULT AIC RATING FED FROMDEVICEMSB21,54642,000UTILITYTRANSFORMERATS-Y18,50635,000 MSB / GEN-YH1Y17,05322,000ATS-YELEV1,76410,000X-ELEVH1118,79042,000MSBH127,03810,000MSBH1M19,76942,000MSBH4110,72222,000MSBH5M16,99322,000MSBSDP1121,97542,000X-SDP11EV20,11442,000SDP11L1119,51542,000SDP11L1219,09642,000SDP11L1318,26942,000SDP11L1P18,18722,000SDP11LPAT4,62010,000SDP11LSS1,25810,000SDP11SDP1213,79722,000X-SDP12L14A12,33622,000SDP12L14B11,29622,000L14AL168,93110,000SDP12L1KA11,23022,000SDP12L1KB10,66322,000L1KASDP216,87742,000X-SDP2L2112,99322,000SDP2L2213,85422,000SDP2FAULT CURRENTSCHEDULE (CONT.)DEVICEFAULT AIC RATING FED FROMDEVICEL2313,61422,000SDP2L246,71410,000SDP2L256,67310,000SDP2SDP316,68842,000X-SDP3L3112,85222,000SDP3L3213,73722,000SDP3L3313,51922,000SDP3L346,68810,000SDP3L356,64710,000SDP3SDP416,52042,000X-SDP4L4112,69922,000SDP4L4213,56522,000SDP4L4313,33222,000SDP4L446,65910,000SDP4L456,61810,000SDP4SDP516,46742,000X-SDP5L5112,69522,000SDP5L5213,51522,000SDP5L5313,28322,000SDP5L546,64410,000SDP5L556,60410,000SDP532 MERCHANT STREET, SUITE 208HONOLULU, HI 96813808-352-5299OWNER:HOMEWOOD SUITES by HILTON SPOKANE VALLEY, WA 13515 E. Carlisle Avenue Spokane Valley, WA 99216FSC PROJECT NO. 21012PERMITDOCUMENTSMay 31, 2024GL8 MirabeauPoint, LLCTMK:PID: 45101.0401 10909 E. Pierce LaneSpokane, WA 99206(509) 919-0901Revision ScheduleNumber Description Date5915 S REGAL STREETSUITE 201SPOKANE, WA 99223PH: 509.473.9218Kelly@kwrllc.comwww.kwrllc.com5/30/2024 12:58:28 PMSTATE OF WASHINGTONREGISTERE D PROFESSIONAL ENG INEER48350 KELLY A NDREW WATERMAN05.31.24POWER ONE-LINEDIAGRAME-601SCALE:1POWER ONE-LINE DIAGRAMNTSGENERAL NOTESFLAG NOTESPROVIDE PERMANENT LABEL AFFIXED TO SERVICE EQUIPMENTDENOTING NOMINAL SYSTEM VOLTAGE, AVAILABLE FAULT CURRENTAT SERVICE DISCONNECT, AND CLEARING TIME OF OVERCURRENTPROTECTIVE DEVICE BASED ON AVAILABLE FAULT CURRENT.PROVIDE ENERGY-REDUCING MAINTENANCE SWITCH FORCOMPLIANCE WITH NEC 240.87.PROVIDE BREAKER WITH ADJUSTABLE TRIP AND GROUND FAULTPROTECTION AS REQUIRED BY NEC 230.95.NEW CT METER BASE PER AVISTA UTILITY STANDARDS.NEW TRANSFORMER PAD / VAULT AND METERING PROVISION PERUTILITY STANDARDS.NEW UNDERGROUND PRIMARY EXTENSION PER UTILITYREQUIREMENTS. TRENCHING / GROUND SLEEVE AND CONDUIT BYCONTRACTOR. CONDUCTORS AND PRIMARY / SECONDARYTERMINATIONS BY AVISTA UTILITIES. COORDINATE FINALREQUIREMENTS WITH SERVING UTILITY.SECONDARY CONDUCTORS AND RACEWAY BY CONTRACTOR, PERAVISTA REQUIREMENTS. AVISTA TO TERMINATE SECONDARYCONDUCTORS ON UTILITY TRANSFORMER. VERIFY INSTALLATIONREQUIREMENTS WITH AVISTA PRIOR TO COMMENCEMENT OF WORK.PROVIDE BUSSMAN OR EQUIVALENT SHUNT TRIP FUSIBLE SWITCHAND CONTROL MODULE, MODEL #PS3T48-R1KGN6BF3 OR APPROVEDEQUAL. COORDINATE EXACT SIZE OF SWITCH AND FUSES WITHELEVATOR SHOP DRAWINGS AND MANUFACTURER REQUIREMENTSPRIOR TO ORDERING. COORDINATE REQUIRED FIRE ALARMCONNECTION WITH OWNER SELECTED FIRE ALARM INSTALLER.NATURAL GAS LEGALLY REQUIRED STANDBY GENERATOR (NEC 701),SIZED AS INDICATED. PROVIDE EQUIPMENT AND APPURTENANCESAND MAKE ALL CONNECTIONS FOR A COMPLETE AND FULLYOPERATIONAL SYSTEM. COORDINATE FUEL CONNECTIONS WITHCIVIL AND MECHANICAL DRAWINGS.PROVIDE 1"C BETWEEN GENERATOR AND AUTOMATIC TRANSFERSWITCH 'ATS-Y'. PROVIDE CONTROL CABLING PER MANUFACTURER'SSHOP DRAWINGS.PROVIDE 1"C BETWEEN GENERATOR AND REMOTE ANNUNCIATOR.PROVIDE CABLING PER MANUFACTURER'S SHOP DRAWINGS.PROVIDE 1"C FROM GENERATOR TO EMERGENCY POWER OFFBUTTON AND PROVIDE CABLE PER MANUFACTURER INSTRUCTIONS.PROVIDE LOW VOLTAGE CONNECTIONS TO GAS SUPPLY SOLENOIDVALVE.BOND TO BUILDING STEEL, TYPICAL FOR SEPARATELY DERIVEDSYSTEMS.SECONDARY CONDUCTORS MUST NOT EXCEED 25' PRIOR TOTERMINATING INTO DOWNSTREAM OVERCURRENT PROTECTION PERNEC 240.21(C)(6).PROVIDE TYPE 2 SURGE PROTECTION DEVICE AND ASSOCIATEDOVERCURRENT PROTECTION.SEE PANEL SCHEDULES FOR ADDITIONAL BRANCH PANELS ANDBREAKER QUANTITIES. FEEDERS ARE TYPICAL FOR SIMILAR BUSSIZES (I.E. #2 FOR100A PANELS, AND #1/0 FOR 125A PANELS).PANEL SHALL BE COOPER BUSSMAN COORDINATION MODULEPANELBOARD. SELECTIVELY COORDINATED. OVERCURRENTDEVICES SHALL BE SELECTIVELY COORDINATED PER NEC 701.32.SELECTIVELY COORDINATE OVERCURRENT DEVICE PER THEREQUIREMENTS OF NEC 701.32. MANUFACTURER TO PROVIDECOORDINATION / POWER SYSTEMS STUDY.FEEDER BETWEEN SOLAR OUTPUT BREAKER AND SOLAR INVERTEREQUIPMENT PROVIDED BY SOLAR INSTALLER. COORDINATE PHASINGWITH SOLAR INSTALLER PRIOR TO COMMENCEMENT OF WORK.1A. ALL CONDUCTORS SHALL BE COPPER, UNLESS DENOTED WITH (AL)FOR COMPACT STRANDED ALUMINUM.B. ALL CONDUCTORS SHALL BE INSTALLED CONTINUOUS (POINT TOPOINT) AND WITHOUT SPLICING, UNLESS OTHERWISE INDICATED.C. FOR CLARITY, BRANCH CIRCUITING IS NOT SHOWN ON ONE-LINEDIAGRAMS. SEE PANEL SCHEDULES.D. PROVIDE PERMANENT LABEL, AFFIXED TO EACH DISTRIBUTIONEQUIPMENT, DENOTING NOMINAL SYSTEM VOLTAGE, AVAILABLEFAULT CURRENT AT EQUIPMENT, LOCATION OF UPSTREAMDISTRIBUTION EQUIPMENT, AND DATE (MONTH AND YEAR) THELABEL WAS APPLIED. LABEL SHALL COMPLY WITH NEC 110.16(A) AND110.16(B).E. METERS SHOWN IN SWITCHBOARDS / DISTRIBUTION PANELS FORWSEC C409 REQUIREMENTS. PROVIDE INTERNAL METERING INLOCATIONS SHOWN FOR MEASURING USAGE OF END-USE LOADCATEGORIES AS OUTLINED IN WSEC SECTION C409 (HVAC, LIGHTING,EV CHARGING, PLUG LOAD). METER SHALL BE CAPABLE OFCOLLECTING AND COMMUNICATING DATA TO BUILDING TELECOMSYSTEM, INCLUDING THE FOLLOWING:-- CURRENT-- VOLTAGE-- KILOWATTS-- KILOWATT HOURS-- KILOVOLT-AMPS-- KILOVOLT-AMP HOURS-- KILOVARS-- POWER FACTORMEASUREMENTS SHALL INCLUDE PER PHASE, PEAK, AND TOTALVALUES. SOFTWARE AND PROGRAMMING SHALL BE PROVIDED FORA COMPLETE AND FUNCTIONAL METERING SOLUTION THAT CAN BEMONITORED ON-SITE.F. ALL DISTRIBUTION EQUIPMENT SHALL BE LABELED WITH THEFOLLOWING:- EQUIPMENT DESIGNATION- SOURCE FROM WHICH EQUIPMENT IS FED- VOLTAGE, PHASE, WIRING CONFIGURATION- AIC RATING- ARC-FLASH HAZARD WARNING- LOCATION OF MAIN DISCONNECT (ON UTILITY SECTION / METERSOCKET)- AVAILABLE FAULT CURRENT- DENOTE VOLTAGE COLORING SYSTEM ON LABEL:208/120V SYSTEM:480/277V SYSTEM:PHASE A BLACKBROWNPHASE B REDORANGEPHASE C BLUEYELLOWNEUTRAL WHITEWHITE/GREYGROUND GREENGREEN234567891011121314151616171819 THIRD FLOOR THIRD FLOORFOURTH FLOOR FOURTH FLOOR FIFTH FLOOR FIFTH FLOOR100A, 480Y/277V 3P 4WPANEL 'H41'400A, 480Y/277V 3P 4WPANEL 'H5M'XFMR 'X-SDP3'225KVAP: 480V 3P 3W DELTAS: 208Y/120V 3P 4W WYEXFMR 'X-SDP4'225KVAP: 480V 3P 3W DELTAS: 208Y/120V 3P 4W WYEXFMR 'X-SDP5'225KVAP: 480V 3P 3W DELTAS: 208Y/120V 3P 4W WYETO 'MSB'TO 'MSB'TO 'MSB'TO 'MSB'TO 'MSB'DISTRIBUTION PANEL 'SDP3'208Y/120V 3P 4W42,000 AIC600A BUS 600/3LSIDISTRIBUTION PANEL 'SDP4'208Y/120V 3P 4W42,000 AIC600A BUS 600/3LSIDISTRIBUTION PANEL 'SDP5'208Y/120V 3P 4W42,000 AIC600A BUS 600/3LSI(2)4"C, 4#500KCMIL(AL),#2/0G(2)4"C, 4#500KCMIL(AL),#2/0G(2)4"C, 4#500KCMIL(AL),#2/0G100A, 208Y/120V 3P 4WPANEL 'L31'100A, 208Y/120V 3P 4WPANEL 'L41'100A, 208Y/120V 3P 4WPANEL 'L51'60A, 208Y/120V 3P 4WPANEL 'ELEV'1"C, 4#6, #8G100/31-1/2"C, 4#1, #6G100/31-1/2"C, 4#1, #6G100/31-1/2"C, 4#1, #6GELEV-2480V 3P 4W14A3/4"C, 4#8, #8GTO 'H1Y'TO 'H1Y'8813#3/013#3/013#3/060/3SPD1560/3SPD1560/3SPD1513#840/3XFMR 'X-ELEV'15KVAP: 480V 3P 3W DELTAS: 208Y/120V 3P 4W WYE1414141430A FUSES30A POWERELEVATOR MODULETO 'H1Y'30A FUSES30A POWERELEVATOR MODULEELEV-1480V 3P 4W14A3/4"C, 4#8, #8G200/3200/3200/3TO PANEL 'L33', SUBFEEDING(7) 100A PANELS AND (1) 125APANELTO PANEL 'L34', SUBFEEDING(8) 100A PANELSTO PANEL 'L35', SUBFEEDING(7) 100A PANELS200/3200/3200/3TO PANEL 'L43', SUBFEEDING(7) 100A PANELS AND (1) 125APANELTO PANEL 'L44', SUBFEEDING(8) 100A PANELSTO PANEL 'L45', SUBFEEDING(7) 100A PANELS200/3200/3200/3PANEL 'L32'208Y/120V 3P 4W200A,PANEL 'L42'208Y/120V 3P 4W200A,PANEL 'L52'208Y/120V 3P 4W200A,200/32-1/2"C,4#250KCMIL(AL),#6G200/32-1/2"C,4#250KCMIL(AL),#6G200/32-1/2"C,4#250KCMIL(AL),#6G161616125A, 208/120V 2P 3WGUEST UNIT 302 PANEL100A, 208/120V 2P 3WGUEST UNIT 304 PANEL125/23#1/0, #6G100/23#2, #8G125A, 208/120V 2P 3WGUEST UNIT 402 PANEL100A, 208/120V 2P 3WGUEST UNIT 404 PANEL125/23#1/0, #6G100/23#2, #8G125A, 208/120V 2P 3WGUEST UNIT 502 PANEL100A, 208/120V 2P 3WGUEST UNIT 504 PANEL125/23#1/0, #6G100/23#2, #8GTO PANEL 'L53', SUBFEEDING(7) 100A PANELS AND (1) 125APANELTO PANEL 'L54', SUBFEEDING(8) 100A PANELSTO PANEL 'L55', SUBFEEDING(7) 100A PANELS2-1/2"C, 4#250KCMIL(AL), #6G2-1/2"C, 4#250KCMIL(AL), #6G2-1/2"C, 4#250KCMIL(AL), #6G1718183"C, 4#350KCMIL(AL), #4G3"C, 4#350KCMIL(AL), #4G3"C, 4#350KCMIL(AL), #4G3"C, 4#350KCMIL(AL), #4G3"C, 4#350KCMIL(AL), #4G3"C, 4#350KCMIL(AL), #4G16TYP32 MERCHANT STREET, SUITE 208HONOLULU, HI 96813808-352-5299OWNER:HOMEWOOD SUITES by HILTON SPOKANE VALLEY, WA 13515 E. Carlisle Avenue Spokane Valley, WA 99216FSC PROJECT NO. 21012PERMITDOCUMENTSMay 31, 2024GL8 MirabeauPoint, LLCTMK:PID: 45101.0401 10909 E. Pierce LaneSpokane, WA 99206(509) 919-0901Revision ScheduleNumber Description Date5915 S REGAL STREETSUITE 201SPOKANE, WA 99223PH: 509.473.9218Kelly@kwrllc.comwww.kwrllc.com5/30/2024 12:58:38 PMSTATE OF WASHINGTONREGISTERE D PROFESSIONAL ENG INEER48350 KELLY A NDREW WATERMAN05.31.24POWER ONE-LINEDIAGRAME-602SCALE:1POWER ONE-LINE DIAGRAM (CONT.)NTSGENERAL NOTESFLAG NOTESPROVIDE PERMANENT LABEL AFFIXED TO SERVICE EQUIPMENTDENOTING NOMINAL SYSTEM VOLTAGE, AVAILABLE FAULT CURRENTAT SERVICE DISCONNECT, AND CLEARING TIME OF OVERCURRENTPROTECTIVE DEVICE BASED ON AVAILABLE FAULT CURRENT.PROVIDE ENERGY-REDUCING MAINTENANCE SWITCH FORCOMPLIANCE WITH NEC 240.87.PROVIDE BREAKER WITH ADJUSTABLE TRIP AND GROUND FAULTPROTECTION AS REQUIRED BY NEC 230.95.NEW CT METER BASE PER AVISTA UTILITY STANDARDS.NEW TRANSFORMER PAD / VAULT AND METERING PROVISION PERUTILITY STANDARDS.NEW UNDERGROUND PRIMARY EXTENSION PER UTILITYREQUIREMENTS. TRENCHING / GROUND SLEEVE AND CONDUIT BYCONTRACTOR. CONDUCTORS AND PRIMARY / SECONDARYTERMINATIONS BY AVISTA UTILITIES. COORDINATE FINALREQUIREMENTS WITH SERVING UTILITY.SECONDARY CONDUCTORS AND RACEWAY BY CONTRACTOR, PERAVISTA REQUIREMENTS. AVISTA TO TERMINATE SECONDARYCONDUCTORS ON UTILITY TRANSFORMER. VERIFY INSTALLATIONREQUIREMENTS WITH AVISTA PRIOR TO COMMENCEMENT OF WORK.PROVIDE BUSSMAN OR EQUIVALENT SHUNT TRIP FUSIBLE SWITCHAND CONTROL MODULE, MODEL #PS3T48-R1KGN6BF3 OR APPROVEDEQUAL. COORDINATE EXACT SIZE OF SWITCH AND FUSES WITHELEVATOR SHOP DRAWINGS AND MANUFACTURER REQUIREMENTSPRIOR TO ORDERING. COORDINATE REQUIRED FIRE ALARMCONNECTION WITH OWNER SELECTED FIRE ALARM INSTALLER.NATURAL GAS LEGALLY REQUIRED STANDBY GENERATOR (NEC 701),SIZED AS INDICATED. PROVIDE EQUIPMENT AND APPURTENANCESAND MAKE ALL CONNECTIONS FOR A COMPLETE AND FULLYOPERATIONAL SYSTEM. COORDINATE FUEL CONNECTIONS WITHCIVIL AND MECHANICAL DRAWINGS.PROVIDE 1"C BETWEEN GENERATOR AND AUTOMATIC TRANSFERSWITCH 'ATS-Y'. PROVIDE CONTROL CABLING PER MANUFACTURER'SSHOP DRAWINGS.PROVIDE 1"C BETWEEN GENERATOR AND REMOTE ANNUNCIATOR.PROVIDE CABLING PER MANUFACTURER'S SHOP DRAWINGS.PROVIDE 1"C FROM GENERATOR TO EMERGENCY POWER OFFBUTTON AND PROVIDE CABLE PER MANUFACTURER INSTRUCTIONS.PROVIDE LOW VOLTAGE CONNECTIONS TO GAS SUPPLY SOLENOIDVALVE.BOND TO BUILDING STEEL, TYPICAL FOR SEPARATELY DERIVEDSYSTEMS.SECONDARY CONDUCTORS MUST NOT EXCEED 25' PRIOR TOTERMINATING INTO DOWNSTREAM OVERCURRENT PROTECTION PERNEC 240.21(C)(6).PROVIDE TYPE 2 SURGE PROTECTION DEVICE AND ASSOCIATEDOVERCURRENT PROTECTION.SEE PANEL SCHEDULES FOR ADDITIONAL BRANCH PANELS ANDBREAKER QUANTITIES. FEEDERS ARE TYPICAL FOR SIMILAR BUSSIZES (I.E. #2 FOR100A PANELS, AND #1/0 FOR 125A PANELS).PANEL SHALL BE COOPER BUSSMAN COORDINATION MODULEPANELBOARD. SELECTIVELY COORDINATED. OVERCURRENTDEVICES SHALL BE SELECTIVELY COORDINATED PER NEC 701.32.SELECTIVELY COORDINATE OVERCURRENT DEVICE PER THEREQUIREMENTS OF NEC 701.32. MANUFACTURER TO PROVIDECOORDINATION / POWER SYSTEMS STUDY.FEEDER BETWEEN SOLAR OUTPUT BREAKER AND SOLAR INVERTEREQUIPMENT PROVIDED BY SOLAR INSTALLER. COORDINATE PHASINGWITH SOLAR INSTALLER PRIOR TO COMMENCEMENT OF WORK.1A. ALL CONDUCTORS SHALL BE COPPER, UNLESS DENOTED WITH (AL)FOR COMPACT STRANDED ALUMINUM.B. ALL CONDUCTORS SHALL BE INSTALLED CONTINUOUS (POINT TOPOINT) AND WITHOUT SPLICING, UNLESS OTHERWISE INDICATED.C. FOR CLARITY, BRANCH CIRCUITING IS NOT SHOWN ON ONE-LINEDIAGRAMS. SEE PANEL SCHEDULES.D. PROVIDE PERMANENT LABEL, AFFIXED TO EACH DISTRIBUTIONEQUIPMENT, DENOTING NOMINAL SYSTEM VOLTAGE, AVAILABLEFAULT CURRENT AT EQUIPMENT, LOCATION OF UPSTREAMDISTRIBUTION EQUIPMENT, AND DATE (MONTH AND YEAR) THELABEL WAS APPLIED. LABEL SHALL COMPLY WITH NEC 110.16(A) AND110.16(B).E. METERS SHOWN IN SWITCHBOARDS / DISTRIBUTION PANELS FORWSEC C409 REQUIREMENTS. PROVIDE INTERNAL METERING INLOCATIONS SHOWN FOR MEASURING USAGE OF END-USE LOADCATEGORIES AS OUTLINED IN WSEC SECTION C409 (HVAC, LIGHTING,EV CHARGING, PLUG LOAD). METER SHALL BE CAPABLE OFCOLLECTING AND COMMUNICATING DATA TO BUILDING TELECOMSYSTEM, INCLUDING THE FOLLOWING:-- CURRENT-- VOLTAGE-- KILOWATTS-- KILOWATT HOURS-- KILOVOLT-AMPS-- KILOVOLT-AMP HOURS-- KILOVARS-- POWER FACTORMEASUREMENTS SHALL INCLUDE PER PHASE, PEAK, AND TOTALVALUES. SOFTWARE AND PROGRAMMING SHALL BE PROVIDED FORA COMPLETE AND FUNCTIONAL METERING SOLUTION THAT CAN BEMONITORED ON-SITE.F. ALL DISTRIBUTION EQUIPMENT SHALL BE LABELED WITH THEFOLLOWING:- EQUIPMENT DESIGNATION- SOURCE FROM WHICH EQUIPMENT IS FED- VOLTAGE, PHASE, WIRING CONFIGURATION- AIC RATING- ARC-FLASH HAZARD WARNING- LOCATION OF MAIN DISCONNECT (ON UTILITY SECTION / METERSOCKET)- AVAILABLE FAULT CURRENT- DENOTE VOLTAGE COLORING SYSTEM ON LABEL:208/120V SYSTEM:480/277V SYSTEM:PHASE A BLACKBROWNPHASE B REDORANGEPHASE C BLUEYELLOWNEUTRAL WHITEWHITE/GREYGROUND GREENGREEN234567891011121314151616171819 NEUTRAL:BUS AMPS:VOLTS:AIC:MOUNTING:LOCATION:KVA LOADCNO.CCTCIRCUIT DESCRIPTIONBAPANEL:OCPNOTESENCLOSURE:42,000800208Y/120V 3P 4WSURFACESEE PLANSSDP11100%NEMA 1200/316.8219.5720.441200/37.1510.5212.662200/30.000.000.003-/30.000.000.004100/31.640.461.455225/32.043.403.466600/333.2833.2839.94760/31.871.312.568-/30.000.000.009-/30.000.000.0010-/30.000.000.0011-/30.000.000.0012TOTAL CONNECTED KVA PER PHASETOTAL CONNECTED AMPS PER PHASETOTAL AMPSCONN. LOADTOTAL KVA(50%>10)(100%)(125%)(125%)RECEPTACLESOTHER MOTORSLARGEST MOTORLIGHTINGCALC. LOADHEATINGCONTINUOUSNONCOIN/DIVERSEKITCHEN EQUIPNONCONTINUOUS(100%)(125%)(100%)METERED DEMAND(125%)NOTES:670.74 573.1480.50 68.54211.85(100%)0.0012.9220.017.050.490.0015.8420.015.640.39COMPUTER657.65236.933.64106.8057.392.140.003.64133.5057.391.940.00(91%)(N/A)0.000.00588.0262.80524.07PANEL L11PANEL L12PANEL L13SPACEPANEL LPATPANEL L1PPANEL EVPANEL LSSSPACESPACESPACESPACENEUTRAL:BUS AMPS:VOLTS:AIC:MOUNTING:LOCATION:KVA LOADCNO.CCTCIRCUIT DESCRIPTIONBAPANEL:OCPNOTESENCLOSURE:22,000150480Y/277V 3P 4WSURFACESEE PLANSH1Y100%NEMA 130/313.3013.3013.30130/313.3013.3013.30230/30.921.540.923-/30.000.000.004-/30.000.000.005-/30.000.000.006TOTAL CONNECTED KVA PER PHASETOTAL CONNECTED AMPS PER PHASETOTAL AMPSCONN. LOADTOTAL KVA(50%>10)(100%)(125%)(125%)RECEPTACLESOTHER MOTORSLARGEST MOTORLIGHTINGCALC. LOADHEATINGCONTINUOUSNONCOIN/DIVERSEKITCHEN EQUIPNONCONTINUOUS(100%)(125%)(100%)METERED DEMAND(125%)NOTES:99.33 101.5427.52 28.1483.19(100%)0.000.7253.9035.330.380.000.7253.9028.270.30COMPUTER108.6590.330.000.000.000.000.000.000.000.000.000.00(N/A)(N/A)0.000.00100.0627.5299.33ELEV-1ELEV-2XFMR X-ELEVSPACESPACESPACE32 MERCHANT STREET, SUITE 208HONOLULU, HI 96813808-352-5299OWNER:HOMEWOOD SUITES by HILTON SPOKANE VALLEY, WA 13515 E. Carlisle Avenue Spokane Valley, WA 99216FSC PROJECT NO. 21012PERMITDOCUMENTSMay 31, 2024GL8 MirabeauPoint, LLCTMK:PID: 45101.0401 10909 E. Pierce LaneSpokane, WA 99206(509) 919-0901Revision ScheduleNumber Description Date5915 S REGAL STREETSUITE 201SPOKANE, WA 99223PH: 509.473.9218Kelly@kwrllc.comwww.kwrllc.com5/30/2024 1:27:14 PMSTATE OF WASHINGTONREGISTERED PROFESSIONAL ENG INEER48350 KELLY A N DREW WATERMAN05.31.24PANEL SCHEDULESE-603 NEUTRAL:BUS AMPS:VOLTS:AIC:MAIN OCPD:LUGS:FED FROM:MOUNTING:LOCATION:CCTNO.NO.CCTCIRCUIT DESCRIPTIONCIRCUIT DESCRIPTIONPANEL:SEE ONE-LINE DIAGRAMENCLOSURE:KVA LOADBCCCTOCPDNOTESACCTOCPDNOTESH5MSEE PLANSSURFACE480Y/277V 3P 4W40022,000MLOSTANDARD100%NEMA 12150/36.939.7040/334 |6.939.70 |65 | |6.939.708750/36.939.7040/3910 |6.939.70 |1211 | |6.939.70141360/30.0011.0920/11516 |0.0011.0920/11817 |20/10.0011.09201920/10.000.0020/1212220/10.000.0020/1242320/120/10.000.002625-/10.000.0020/12728-/10.000.0020/13029-/120/10.000.003231-/10.000.00-/13334-/10.000.00-/13635-/1-/10.000.003837-/10.000.00-/13940-/10.000.00-/14241-/1-/10.000.00TOTAL CALCULATED AMPSCONN. KVATOTAL KVA(50%>10)(100%)(125%)(125%)RECEPTACLESOTHER MOTORSLARGEST MOTORLIGHTINGCALC. KVAHEATINGCONTINUOUSNONCOIN/DIVERSEKITCHEN EQUIPNONCONTINUOUS(100%)(125%)(100%)TOTAL CONNECTED LOAD (KVA)NOTES:METERED DEMAND(125%)COOLINGABCTOTAL CONNECTED LOAD (AMPS)ABC133.02(100%)0.000.0099.7741.570.000.000.0099.7733.260.00COMPUTER170.00141.340.000.000.000.000.000.000.000.000.000.00(N/A)(N/A)0.000.00160.000.000.00(N/A)44.3444.3444.34160.00 160.00160.00CU-02ACU-02BERV-01SPARESPARESPARESPACESPACESPACESPACESPACESPACESPACESPACESPACECU-03ACU-03BSPARESPARESPARESPARESPARESPARESPARESPARESPARESPACESPACESPACESPACESPACESPACENEUTRAL:BUS AMPS:VOLTS:AIC:MAIN OCPD:LUGS:FED FROM:MOUNTING:LOCATION:CCTNO.NO.CCTCIRCUIT DESCRIPTIONCIRCUIT DESCRIPTIONPANEL:SEE ONE-LINE DIAGRAMENCLOSURE:KVA LOADBCCCTOCPDNOTESACCTOCPDNOTESH11SEE PLANSSURFACE480Y/277V 3P 4W10042,000MLOSTANDARD100%NEMA 12120/10.000.7020/13420/10.001.1220/16520/120/10.000.788720/10.002.8020/191020/10.000.2720/1121120/120/10.000.39141320/10.001.2520/1151620/10.000.7020/11817-/120/10.000.002019-/10.000.0020/12122-/10.000.0020/12423-/120/10.000.002625-/10.000.00-/12728-/10.000.00-/13029-/1-/10.000.003231-/10.000.00-/13334-/10.000.00-/13635-/1-/10.000.003837-/10.000.00-/13940-/10.000.00-/14241-/1-/10.000.00TOTAL CALCULATED AMPSCONN. KVATOTAL KVA(50%>10)(100%)(125%)(125%)RECEPTACLESOTHER MOTORSLARGEST MOTORLIGHTINGCALC. KVAHEATINGCONTINUOUSNONCOIN/DIVERSEKITCHEN EQUIPNONCONTINUOUS(100%)(125%)(100%)TOTAL CONNECTED LOAD (KVA)NOTES:METERED DEMAND(125%)COOLINGABCTOTAL CONNECTED LOAD (AMPS)ABC8.00(100%)0.000.000.000.0010.010.000.000.000.008.00COMPUTER12.0310.010.000.000.000.000.000.000.000.000.000.00(N/A)(N/A)0.000.009.630.000.00(N/A)4.742.091.177.544.2217.13LTG, LTG - EXTLTG - EXTLTGLTGLTGLTGLTGLTGSPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPARESPARESPARESPARESPARESPARESPARESPARESPARESPARESPARESPARESPACESPACESPACESPACESPACESPACESPACESPACESPACENEUTRAL:BUS AMPS:VOLTS:AIC:MAIN OCPD:LUGS:FED FROM:MOUNTING:LOCATION:CCTNO.NO.CCTCIRCUIT DESCRIPTIONCIRCUIT DESCRIPTIONPANEL:SEE ONE-LINE DIAGRAMENCLOSURE:KVA LOADBCCCTOCPDNOTESACCTOCPDNOTESH12SEE PLANSSURFACE480Y/277V 3P 4W10010,000MLOSTANDARD100%NEMA 12120/10.001.2920/13420/10.001.0620/16520/120/10.000.918720/10.001.2120/191020/10.000.5120/11211-/120/10.000.001413-/10.000.0020/11516-/10.000.0020/11817-/120/10.000.002019-/10.000.0020/12122-/10.000.0020/12423-/120/10.000.002625-/10.000.00-/12728-/10.000.00-/13029-/1-/10.000.003231-/10.000.00-/13334-/10.000.00-/13635-/1-/10.000.003837-/10.000.00-/13940-/10.000.00-/14241-/1-/10.000.00TOTAL CALCULATED AMPSCONN. KVATOTAL KVA(50%>10)(100%)(125%)(125%)RECEPTACLESOTHER MOTORSLARGEST MOTORLIGHTINGCALC. KVAHEATINGCONTINUOUSNONCOIN/DIVERSEKITCHEN EQUIPNONCONTINUOUS(100%)(125%)(100%)TOTAL CONNECTED LOAD (KVA)NOTES:METERED DEMAND(125%)COOLINGABCTOTAL CONNECTED LOAD (AMPS)ABC4.97(100%)0.000.000.000.006.210.000.000.000.004.97COMPUTER7.476.210.000.000.000.000.000.000.000.000.000.00(N/A)(N/A)0.000.005.980.000.00(N/A)2.501.560.915.643.279.02LTGLTGLTGLTGLTGSPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPARESPARESPARESPARESPARESPARESPARESPARESPARESPARESPARESPARESPACESPACESPACESPACESPACESPACESPACESPACESPACENEUTRAL:BUS AMPS:VOLTS:AIC:MAIN OCPD:LUGS:FED FROM:MOUNTING:LOCATION:CCTNO.NO.CCTCIRCUIT DESCRIPTIONCIRCUIT DESCRIPTIONPANEL:SEE ONE-LINE DIAGRAMENCLOSURE:KVA LOADBCCCTOCPDNOTESACCTOCPDNOTESH1MSEE PLANSSURFACE480Y/277V 3P 4W20042,000MLOSTANDARD100%NEMA 12130/30.835.2715/334 |0.835.27 |65 | |0.835.278720/10.830.0015/391020/10.830.00 |121120/1 |0.830.00141320/10.000.0020/1151620/10.000.0020/1181720/120/10.000.00201920/10.000.00-/1212220/10.000.00-/1242320/1-/10.000.002625-/10.000.00-/12728-/10.000.00-/13029-/1-/10.000.003231-/10.000.00-/13334-/10.000.00-/13635-/1-/10.000.003837-/10.000.00-/13940-/10.000.00-/14241-/1-/10.000.00TOTAL CALCULATED AMPSCONN. KVATOTAL KVA(50%>10)(100%)(125%)(125%)RECEPTACLESOTHER MOTORSLARGEST MOTORLIGHTINGCALC. KVAHEATINGCONTINUOUSNONCOIN/DIVERSEKITCHEN EQUIPNONCONTINUOUS(100%)(125%)(100%)TOTAL CONNECTED LOAD (KVA)NOTES:METERED DEMAND(125%)COOLINGABCTOTAL CONNECTED LOAD (AMPS)ABC20.78(100%)0.000.004.9919.750.000.000.004.9915.800.00COMPUTER29.7524.730.000.000.000.000.000.000.000.000.000.00(N/A)(N/A)0.000.0025.000.000.00(N/A)6.936.936.9325.0025.0025.00AHU-01SPARESPARESPARESPARESPARESPARESPARESPARESPARESPACESPACESPACESPACESPACESPACESPACESPACESPACECU-01ACU-01BSPARESPARESPARESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACENEUTRAL:BUS AMPS:VOLTS:AIC:MAIN OCPD:LUGS:FED FROM:MOUNTING:LOCATION:CCTNO.NO.CCTCIRCUIT DESCRIPTIONCIRCUIT DESCRIPTIONPANEL:SEE ONE-LINE DIAGRAMENCLOSURE:KVA LOADBCCCTOCPDNOTESACCTOCPDNOTESH41SEE PLANSSURFACE480Y/277V 3P 4W10022,000MLOSTANDARD100%NEMA 12120/10.001.0120/13420/10.001.0120/16520/120/10.001.0187-/10.000.0020/1910-/10.000.0020/11211-/120/10.000.001413-/10.000.0020/11516-/10.000.0020/11817-/120/10.000.002019-/10.000.0020/12122-/10.000.0020/12423-/120/10.000.002625-/10.000.00-/12728-/10.000.00-/13029-/1-/10.000.003231-/10.000.00-/13334-/10.000.00-/13635-/1-/10.000.003837-/10.000.00-/13940-/10.000.00-/14241-/1-/10.000.00TOTAL CALCULATED AMPSCONN. KVATOTAL KVA(50%>10)(100%)(125%)(125%)RECEPTACLESOTHER MOTORSLARGEST MOTORLIGHTINGCALC. KVAHEATINGCONTINUOUSNONCOIN/DIVERSEKITCHEN EQUIPNONCONTINUOUS(100%)(125%)(100%)TOTAL CONNECTED LOAD (KVA)NOTES:METERED DEMAND(125%)COOLINGABCTOTAL CONNECTED LOAD (AMPS)ABC3.03(100%)0.000.000.000.003.790.000.000.000.003.03COMPUTER4.563.790.000.000.000.000.000.000.000.000.000.00(N/A)(N/A)0.000.003.640.000.00(N/A)1.011.011.013.653.653.65LTGLTGLTGSPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPARESPARESPARESPARESPARESPARESPARESPARESPARESPARESPARESPARESPACESPACESPACESPACESPACESPACESPACESPACESPACE32 MERCHANT STREET, SUITE 208HONOLULU, HI 96813808-352-5299OWNER:HOMEWOOD SUITES by HILTON SPOKANE VALLEY, WA 13515 E. Carlisle Avenue Spokane Valley, WA 99216FSC PROJECT NO. 21012PERMITDOCUMENTSMay 31, 2024GL8 MirabeauPoint, LLCTMK:PID: 45101.0401 10909 E. Pierce LaneSpokane, WA 99206(509) 919-0901Revision ScheduleNumber Description Date5915 S REGAL STREETSUITE 201SPOKANE, WA 99223PH: 509.473.9218Kelly@kwrllc.comwww.kwrllc.com5/30/2024 1:27:19 PMSTATE OF WASHINGTONREGISTERED PROFESSIONAL ENG INEER48350 KELLY A N DREW WATERMAN05.31.24PANEL SCHEDULESE-604 a.PROVIDE LOCKABLE CIRCUIT BREAKER.b. PROVIDE GFCI CIRCUIT BREAKER WITH 6mA TRIP.c. PROVIDE GFP CIRCUIT BREAKER WITH 30mA TRIP.d. CIRCUIT SHALL BE ROUTED THROUGH ASSOCIATED KITCHEN HOODCONTROL PANEL. SEE HOOD SHOP DRAWINGS AND COORDINATE WITHHOOD PROVIDER PRIOR TO INSTALLATION.e. SPACE FOR SHUNT TRIP MODULE. CIRCUIT SHALL DE-ENERGIZE UPONACTIVATION OF TYPE 1 KITCHEN HOOD SYSTEM. PROVIDE CONDUCTORSFROM PANEL TO HOOD ANSUL SYSTEM. SEE MANUFACTURER WIRINGDIAGRAMS FOR ADDITIONAL INFORMATION.bbbbbbaacbbbbbbbba,ba,bbaaddeeeeeeebbabbbaaaaaaaaaaaaaaaaaa. PROVIDE LOCKABLE CIRCUIT BREAKER.b. PROVIDE GFCI CIRCUIT BREAKER WITH 6mA TRIP.c. PROVIDE CIRCUIT BREAKER WITH RED HANDLE.a. PROVIDE LOCKABLE CIRCUIT BREAKER.b. PROVIDE GFCI CIRCUIT BREAKER WITH 6mA TRIP.c. PROVIDE GFP CIRCUIT BREAKER WITH 30mA TRIP.d. CIRCUIT SHALL BE ROUTED THROUGH ASSOCIATED KITCHEN HOODCONTROL PANEL. SEE HOOD SHOP DRAWINGS AND COORDINATE WITHHOOD PROVIDER PRIOR TO INSTALLATION.e. SPACE FOR SHUNT TRIP MODULE. CIRCUIT SHALL DE-ENERGIZE UPONACTIVATION OF TYPE 1 KITCHEN HOOD SYSTEM. PROVIDE CONDUCTORSFROM PANEL TO HOOD ANSUL SYSTEM. SEE MANUFACTURER WIRINGDIAGRAMS FOR ADDITIONAL INFORMATION.aa. PROVIDE LOCKABLE CIRCUIT BREAKER.b. PROVIDE GFCI CIRCUIT BREAKER WITH 6mA TRIP.c. PROVIDE CIRCUIT BREAKER WITH RED HANDLE.a. PROVIDE LOCKABLE CIRCUIT BREAKER.b. PROVIDE GFCI CIRCUIT BREAKER WITH 6mA TRIP.c. PROVIDE CIRCUIT BREAKER WITH RED HANDLE.NEUTRAL:BUS AMPS:VOLTS:AIC:MAIN OCPD:LUGS:FED FROM:MOUNTING:LOCATION:CCTNO.NO.CCTCIRCUIT DESCRIPTIONCIRCUIT DESCRIPTIONPANEL:SEE ONE-LINE DIAGRAMENCLOSURE:KVA LOADBCCCTOCPDNOTESACCTOCPDNOTESEVSEE PLANSSURFACE208Y/120V 3P 4W60042,000MLOSTANDARD100%NEMA 12140/23.333.3340/234 |3.333.33 |6540/240/23.333.3387 |3.333.33 |91040/23.333.3340/21211 | |3.333.33141340/23.333.3340/21516 |3.333.33 |181740/240/23.333.332019 |3.333.33 |212240/23.333.3340/22423 | |3.333.33262540/23.333.3340/22728 |3.333.33 |302940/240/23.333.333231 |3.333.33 |3334-/10.000.00-/13635-/1-/10.000.003837-/10.000.00-/13940-/10.000.00-/14241-/1-/10.000.00TOTAL CALCULATED AMPSCONN. KVATOTAL KVA(50%>10)(100%)(125%)(125%)RECEPTACLESOTHER MOTORSLARGEST MOTORLIGHTINGCALC. KVAHEATINGCONTINUOUSNONCOIN/DIVERSEKITCHEN EQUIPNONCONTINUOUS(100%)(125%)(100%)TOTAL CONNECTED LOAD (KVA)NOTES:METERED DEMAND(125%)COOLINGABCTOTAL CONNECTED LOAD (AMPS)ABC106.50(100%)0.000.000.000.000.000.000.000.000.000.00COMPUTER369.50133.120.00106.500.000.000.000.00133.120.000.000.00(N/A)(N/A)0.000.00295.600.000.00(N/A)39.9433.2833.28278.97 278.97332.55EV-1EV-2EV-3 (FUTURE)EV-4 (FUTURE)EV-5 (FUTURE)EV-6 (FUTURE)EV-7 (FUTURE)EV-8 (FUTURE)SPACESPACESPACESPACESPACEEV-9 (FUTURE)EV-10 (FUTURE)EV-11 (FUTURE)EV-12 (FUTURE)EV-13 (FUTURE)EV-14 (FUTURE)EV-15 (FUTURE)EV-16 (FUTURE)SPACESPACESPACESPACESPACENEUTRAL:BUS AMPS:VOLTS:AIC:MAIN OCPD:LUGS:FED FROM:MOUNTING:LOCATION:CCTNO.NO.CCTCIRCUIT DESCRIPTIONCIRCUIT DESCRIPTIONPANEL:SEE ONE-LINE DIAGRAMENCLOSURE:KVA LOADBCCCTOCPDNOTESACCTOCPDNOTESELEVSEE PLANSSURFACE208Y/120V 3P 4W6010,00040STANDARD100%NEMA 12120/11.180.3620/13420/11.180.3620/16520/120/10.000.308720/10.000.0020/191020/10.000.0020/1121120/120/10.000.00141320/10.000.0020/1151620/10.000.0020/1181720/1-/10.000.002019-/10.000.00-/12122-/10.000.00-/12423-/1-/10.000.00TOTAL CALCULATED AMPSCONN. KVATOTAL KVA(50%>10)(100%)(125%)(125%)RECEPTACLESOTHER MOTORSLARGEST MOTORLIGHTINGCALC. KVAHEATINGCONTINUOUSNONCOIN/DIVERSEKITCHEN EQUIPNONCONTINUOUS(100%)(125%)(100%)TOTAL CONNECTED LOAD (KVA)NOTES:METERED DEMAND(125%)COOLINGABCTOTAL CONNECTED LOAD (AMPS)ABC3.38(100%)0.000.721.181.470.380.000.721.181.180.30COMPUTER10.403.750.000.000.000.000.000.000.000.000.000.00(N/A)(N/A)0.000.009.370.000.00(N/A)1.541.540.3012.802.5312.80RECRECLTGSPARESPARESPARESPARESPARESPARESPACESPACESPACESP-1SP-2SPARESPARESPARESPARESPARESPARESPACESPACESPACESPACENEUTRAL:BUS AMPS:VOLTS:AIC:MAIN OCPD:LUGS:FED FROM:MOUNTING:LOCATION:CCTNO.NO.CCTCIRCUIT DESCRIPTIONCIRCUIT DESCRIPTIONPANEL:SEE ONE-LINE DIAGRAMENCLOSURE:KVA LOADBCCCTOCPDNOTESACCTOCPDNOTESL1PSEE PLANSSURFACE208Y/120V 3P 4W22522,000MLOSTANDARD100%NEMA 4X2120/10.541.9220/13420/10.481.9220/16520/120/10.121.928720/10.600.4020/191020/10.600.4020/1121120/120/10.000.00141320/10.000.0020/1151620/10.000.0020/1181720/120/10.000.00201920/10.000.0020/1212220/10.000.0020/12423-/1-/10.000.002625-/10.000.00-/12728-/10.000.00-/13029-/1-/10.000.00TOTAL CALCULATED AMPSCONN. KVATOTAL KVA(50%>10)(100%)(125%)(125%)RECEPTACLESOTHER MOTORSLARGEST MOTORLIGHTINGCALC. KVAHEATINGCONTINUOUSNONCOIN/DIVERSEKITCHEN EQUIPNONCONTINUOUS(100%)(125%)(100%)TOTAL CONNECTED LOAD (KVA)NOTES:METERED DEMAND(125%)COOLINGABCTOTAL CONNECTED LOAD (AMPS)ABC8.89(100%)0.000.543.842.400.000.000.543.841.920.00COMPUTER26.019.370.000.002.590.000.000.000.002.590.000.00(N/A)(N/A)0.000.0024.680.000.00(N/A)3.463.402.0428.3017.0028.80PEQ-1PEQ-2PEQ-3PEQ-6PEQ-7SPARESPARESPARESPARESPARESPARESPACESPACESPACESPACERECPEQ-8.1, PEQ-8.2PEQ-9, PEQ-10PEQ-11PEQ-12SPARESPARESPARESPARESPARESPARESPACESPACESPACESPACENEUTRAL:BUS AMPS:VOLTS:AIC:MAIN OCPD:LUGS:FED FROM:MOUNTING:LOCATION:CCTNO.NO.CCTCIRCUIT DESCRIPTIONCIRCUIT DESCRIPTIONPANEL:SEE ONE-LINE DIAGRAMENCLOSURE:KVA LOADBCCCTOCPDNOTESACCTOCPDNOTESL1KASEE PLANSFLUSH208Y/120V 3P 4W40022,000MLOFEEDTHRU100%NEMA 12120/11.300.2415/13420/12.640.7830/36520/1 |2.640.868720/12.641.44 |91020/12.642.0030/3121120/1 |2.640.36141320/22.640.90 |1516 |1.510.9020/1181720/120/10.960.60201920/11.300.1915/2212220/11.300.65 |242320/120/11.300.65262520/11.000.6520/1272820/11.800.6520/1302920/120/10.501.14323120/20.370.9915/33334 |0.370.99 |363520/1 |0.371.92383720/10.830.1815/2394020/10.830.00 |424120/120/10.000.00444320/10.000.0020/14546-/10.000.0020/14847-/1-/10.000.005049-/10.000.00-/15152-/10.000.00-/15453-/1-/10.000.00TOTAL CALCULATED AMPSCONN. KVATOTAL KVA(50%>10)(100%)(125%)(125%)RECEPTACLESOTHER MOTORSLARGEST MOTORLIGHTINGCALC. KVAHEATINGCONTINUOUSNONCOIN/DIVERSEKITCHEN EQUIPNONCONTINUOUS(100%)(125%)(100%)TOTAL CONNECTED LOAD (KVA)NOTES:METERED DEMAND(125%)COOLINGABCTOTAL CONNECTED LOAD (AMPS)ABC61.38(100%)0.000.180.000.243.000.000.180.000.192.40COMPUTER116.8942.111.000.000.7056.910.001.000.000.7036.990.00(65%)(N/A)0.000.00170.380.000.00(N/A)20.0224.1417.22202.50 144.15171.12KE-2.1KE-2.2KE-2KE-41KE-50KE-31KE-20KE-7KE-7.1KE-61AKE-61BKE-61CKE-61DKE-89KE-85KE-84RECSPARESPARESPARESPACESPACESPACESPACESPACEKE-26KE-22BKE-22AKE-56KE-30KE-60KE-29WALK-IN CONDENSATE LINE HEAT TRACEH-1H-1.1MAU-01EF-03SPARESPARESPARESPACESPACESPACESPACENEUTRAL:BUS AMPS:VOLTS:AIC:MAIN OCPD:LUGS:FED FROM:MOUNTING:LOCATION:CCTNO.NO.CCTCIRCUIT DESCRIPTIONCIRCUIT DESCRIPTIONPANEL:SEE ONE-LINE DIAGRAMENCLOSURE:KVA LOADBCCCTOCPDNOTESACCTOCPDNOTESLPATSEE PLANSSURFACE208Y/120V 3P 4W10010,000MLOSTANDARD100%NEMA 12120/10.360.1020/13420/10.360.1020/16520/120/10.900.748720/10.900.0920/191020/10.000.0020/1121120/120/10.000.00141320/10.000.0020/1151620/10.000.0020/1181720/120/10.000.00201920/10.000.0020/12122-/10.000.00-/12423-/1-/10.000.002625-/10.000.00-/12728-/10.000.00-/13029-/1-/10.000.003231-/10.000.00-/13334-/10.000.00-/13635-/1-/10.000.003837-/10.000.00-/13940-/10.000.00-/14241-/1-/10.000.00TOTAL CALCULATED AMPSCONN. KVATOTAL KVA(50%>10)(100%)(125%)(125%)RECEPTACLESOTHER MOTORSLARGEST MOTORLIGHTINGCALC. KVAHEATINGCONTINUOUSNONCOIN/DIVERSEKITCHEN EQUIPNONCONTINUOUS(100%)(125%)(100%)TOTAL CONNECTED LOAD (KVA)NOTES:METERED DEMAND(125%)COOLINGABCTOTAL CONNECTED LOAD (AMPS)ABC3.55(100%)0.002.520.000.000.110.002.520.000.000.09COMPUTER9.653.480.000.000.000.940.000.000.000.000.850.00(90%)(N/A)0.000.009.860.000.00(N/A)1.450.461.643.8313.7012.06KE-96AKE-96BKE-98LTGSPARESPARESPARESPARESPARESPARESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACEFIREPLACE IGNITERRECRECRECSPARESPARESPARESPARESPARESPARESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACENEUTRAL:BUS AMPS:VOLTS:AIC:MAIN OCPD:LUGS:FED FROM:MOUNTING:LOCATION:CCTNO.NO.CCTCIRCUIT DESCRIPTIONCIRCUIT DESCRIPTIONPANEL:SEE ONE-LINE DIAGRAMENCLOSURE:KVA LOADBCCCTOCPDNOTESACCTOCPDNOTESLSSSEE PLANSSURFACE208Y/120V 3P 4W6010,00060STANDARD100%NEMA 12120/10.590.1020/23420/10.590.72 |6530/220/10.001.8787 |0.001.8720/191020/10.000.0020/1121120/120/10.000.00141320/10.000.0020/1151620/10.000.0020/1181720/1-/10.000.00201920/10.000.00-/12122-/10.000.00-/12423-/1-/10.000.002625-/10.000.00-/12728-/10.000.00-/13029-/1-/10.000.003231-/10.000.00-/13334-/10.000.00-/13635-/1-/10.000.003837-/10.000.00-/13940-/10.000.00-/14241-/1-/10.000.00TOTAL CALCULATED AMPSCONN. KVATOTAL KVA(50%>10)(100%)(125%)(125%)RECEPTACLESOTHER MOTORSLARGEST MOTORLIGHTINGCALC. KVAHEATINGCONTINUOUSNONCOIN/DIVERSEKITCHEN EQUIPNONCONTINUOUS(100%)(125%)(100%)TOTAL CONNECTED LOAD (KVA)NOTES:METERED DEMAND(125%)COOLINGABCTOTAL CONNECTED LOAD (AMPS)ABC5.74(100%)0.000.721.184.680.130.000.721.183.740.10COMPUTER18.616.700.000.000.000.000.000.000.000.000.000.00(N/A)(N/A)0.000.0015.940.000.00(N/A)2.561.311.8711.2618.0022.21LTGRECUH-02SPARESPARESPARESPARESPARESPARESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACEOD-1SPARESPARESPARESPARESPARESPARESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACENEUTRAL:BUS AMPS:VOLTS:AIC:MAIN OCPD:LUGS:FED FROM:MOUNTING:LOCATION:CCTNO.NO.CCTCIRCUIT DESCRIPTIONCIRCUIT DESCRIPTIONPANEL:SEE ONE-LINE DIAGRAMENCLOSURE:KVA LOADBCCCTOCPDNOTESACCTOCPDNOTESL1KBSEE PLANSFLUSH208Y/120V 3P 4W40022,000MLOSTANDARD100%NEMA 12120/11.301.3920/234-/11.300.00 |6520/1-/10.000.3687-/11.300.0020/291030/21.302.91 |1211 |-/10.002.911413-/11.350.0020/2151620/11.350.20 |1817-/1-/10.000.00201920/10.000.0020/1212220/10.000.0020/1242320/120/10.000.002625-/10.000.00-/12728-/10.000.00-/13029-/1-/10.000.003231-/10.000.00-/13334-/10.000.00-/13635-/1-/10.000.003837-/10.000.00-/13940-/10.000.00-/14241-/1-/10.000.00TOTAL CALCULATED AMPSCONN. KVATOTAL KVA(50%>10)(100%)(125%)(125%)RECEPTACLESOTHER MOTORSLARGEST MOTORLIGHTINGCALC. KVAHEATINGCONTINUOUSNONCOIN/DIVERSEKITCHEN EQUIPNONCONTINUOUS(100%)(125%)(100%)TOTAL CONNECTED LOAD (KVA)NOTES:METERED DEMAND(125%)COOLINGABCTOTAL CONNECTED LOAD (AMPS)ABC15.68(100%)0.000.000.000.000.000.000.000.000.000.00COMPUTER28.4810.260.000.000.2015.480.000.000.000.2010.060.00(65%)(N/A)0.000.0043.510.000.00(N/A)5.347.063.2759.0230.6348.38KE-42BSPACE FOR SHUNT TRIP MODULEKE-48SPACE FOR SHUNT TRIP MODULEKE-42ASPACE FOR SHUNT TRIP MODULEGAS SOLENOIDSPACE FOR SHUNT TRIP MODULESPARESPARESPARESPACESPACESPACESPACESPACESPACESPACESPACESPACEKE-49BSPACE FOR SHUNT TRIP MODULEKE-49ASPACE FOR SHUNT TRIP MODULEKE-47SPACE FOR SHUNT TRIP MODULESPARESPARESPARESPACESPACESPACESPACESPACESPACESPACESPACESPACE32 MERCHANT STREET, SUITE 208HONOLULU, HI 96813808-352-5299OWNER:HOMEWOOD SUITES by HILTON SPOKANE VALLEY, WA 13515 E. Carlisle Avenue Spokane Valley, WA 99216FSC PROJECT NO. 21012PERMITDOCUMENTSMay 31, 2024GL8 MirabeauPoint, LLCTMK:PID: 45101.0401 10909 E. Pierce LaneSpokane, WA 99206(509) 919-0901Revision ScheduleNumber Description Date5915 S REGAL STREETSUITE 201SPOKANE, WA 99223PH: 509.473.9218Kelly@kwrllc.comwww.kwrllc.com5/30/2024 1:27:28 PMSTATE OF WASHINGTONREGISTERED PROFESSIONAL ENG INEER48350 KELLY A N DREW WATERMAN05.31.24PANEL SCHEDULESE-605 a.PANEL SCHEDULE SHOWN FOR BREAKER QUANTITIES AND PHASE / LOADBALANCING. SEE ALTERNATE CALCULATIONS ON SHEET E-603 FOR CALCULATEDLOAD BASED UPON NEC ALLOWABLE DEMAND FACTORS.bbbbbbbbbbbbbaaaaacaaaabaaa. PROVIDE LOCKABLE CIRCUIT BREAKER.b. PROVIDE GFCI CIRCUIT BREAKER WITH 6mA TRIP.c. PROVIDE CIRCUIT BREAKER WITH RED HANDLE.a. PROVIDE LOCKABLE CIRCUIT BREAKER.b. PROVIDE GFCI CIRCUIT BREAKER WITH 6mA TRIP.c. PROVIDE CIRCUIT BREAKER WITH RED HANDLE.a. PROVIDE LOCKABLE CIRCUIT BREAKER.b. PROVIDE GFCI CIRCUIT BREAKER WITH 6mA TRIP.c. PROVIDE CIRCUIT BREAKER WITH RED HANDLE.ccccNEUTRAL:BUS AMPS:VOLTS:AIC:MAIN OCPD:LUGS:FED FROM:MOUNTING:LOCATION:CCTNO.NO.CCTCIRCUIT DESCRIPTIONCIRCUIT DESCRIPTIONPANEL:SEE ONE-LINE DIAGRAMENCLOSURE:KVA LOADBCCCTOCPDNOTESACCTOCPDNOTESL16SEE PLANSSURFACE208Y/120V 3P 4W20010,000MLOSTANDARD100%NEMA 121100/25.805.72100/234 |5.415.59 |65100/2100/25.725.7287 |5.595.59 |910100/25.805.72100/21211 | |5.775.591413100/25.805.80100/21516 |5.765.77 |1817100/2-/10.005.802019 |0.005.41-/12122-/10.000.00-/12423-/1-/10.000.002625-/10.000.00-/12728-/10.000.00-/13029-/1-/10.000.00TOTAL CALCULATED AMPSCONN. KVATOTAL KVA(50%>10)(100%)(125%)(125%)RECEPTACLESOTHER MOTORSLARGEST MOTORLIGHTINGCALC. KVAHEATINGCONTINUOUSNONCOIN/DIVERSEKITCHEN EQUIPNONCONTINUOUS(100%)(125%)(100%)TOTAL CONNECTED LOAD (KVA)NOTES:METERED DEMAND(125%)COOLINGABCTOTAL CONNECTED LOAD (AMPS)ABC102.32(100%)0.0013.910.000.006.710.0017.820.000.005.37COMPUTER276.8899.750.000.0079.130.000.000.000.0079.130.000.00(N/A)(N/A)0.000.00284.000.000.00(N/A)39.7034.0328.59284.93 238.56330.99PANEL A-129PANEL A-131PANEL A-133PANEL F-135PANEL B-137SPACESPACESPACESPACESPACEPANEL B-130PANEL A-134PANEL F-136PANEL D-138SPACESPACESPACESPACESPACESPACESPACENEUTRAL:BUS AMPS:VOLTS:AIC:MAIN OCPD:LUGS:FED FROM:MOUNTING:LOCATION:CCTNO.NO.CCTCIRCUIT DESCRIPTIONCIRCUIT DESCRIPTIONPANEL:SEE ONE-LINE DIAGRAMENCLOSURE:KVA LOADBCCCTOCPDNOTESACCTOCPDNOTESL11SEE PLANSSURFACE208Y/120V 3P 4W20042,000MLOSTANDARD100%NEMA 12115/31.441.2015/334 |1.441.20 |65 | |1.441.208715/31.441.2015/3910 |1.441.20 |1211 | |1.441.20141315/31.441.2015/31516 |1.441.20 |1817 | |1.441.20201920/12.381.8030/2212220/12.381.80 |242320/130/22.381.80262520/12.381.80 |272820/12.380.8030/2302920/1 |2.381.20323120/12.381.0030/2333420/12.380.60 |363520/120/10.540.60383720/10.190.6020/1394020/10.720.6020/1424120/120/10.000.00444320/10.000.0020/1454620/10.000.0020/14847-/1-/10.000.005049-/10.000.00-/15152-/10.000.00-/15453-/1-/10.000.00TOTAL CALCULATED AMPSCONN. KVATOTAL KVA(50%>10)(100%)(125%)(125%)RECEPTACLESOTHER MOTORSLARGEST MOTORLIGHTINGCALC. KVAHEATINGCONTINUOUSNONCOIN/DIVERSEKITCHEN EQUIPNONCONTINUOUS(100%)(125%)(100%)TOTAL CONNECTED LOAD (KVA)NOTES:METERED DEMAND(125%)COOLINGABCTOTAL CONNECTED LOAD (AMPS)ABC56.83(100%)0.000.002.530.750.000.000.002.530.600.00COMPUTER158.1656.980.000.0052.501.200.000.000.0052.501.200.00(100%)(N/A)0.000.00157.740.000.00(N/A)20.4419.5716.82163.40 140.05170.65WASH-2.1WASH-2.2WASH-2.3WASH-1.1WASH-1.2WASH-1.3WASH-1.4REF-1DW-1MW-1TREAD-1TREAD-2TREAD-3TREAD-4SPARESPARESPARESPACESPACESPACESPACEDRY-2.1DRY-2.2DRY-2.3DRY-1.1DRY-1.2DRY-1.3DRY-1.4BIKE-1, ELLIP-1, ELLIP-2ICE-1DF-1SPARESPARESPARESPACESPACESPACESPACENEUTRAL:BUS AMPS:VOLTS:AIC:MAIN OCPD:LUGS:FED FROM:MOUNTING:LOCATION:CCTNO.NO.CCTCIRCUIT DESCRIPTIONCIRCUIT DESCRIPTIONPANEL:SEE ONE-LINE DIAGRAMENCLOSURE:KVA LOADBCCCTOCPDNOTESACCTOCPDNOTESL13SEE PLANSSURFACE208Y/120V 3P 4W20042,000MLOSTANDARD100%NEMA 12120/10.000.0020/13420/10.000.0020/16520/120/10.000.008720/10.000.0020/191020/10.000.0020/1121120/120/10.000.001413-/10.000.00-/11516-/10.000.00-/11817-/1-/10.000.002019-/10.000.00-/12122-/10.000.00-/12423-/1-/10.000.002625-/10.000.00-/12728-/10.000.00-/13029-/1-/10.000.003231-/10.000.00-/13334-/10.000.00-/13635-/1-/10.000.003837-/10.000.00-/13940-/10.000.00-/14241-/1-/10.000.004443-/10.000.00-/14546-/10.000.00-/14847-/1-/10.000.005049-/10.000.00-/15152-/10.000.00-/15453-/1-/10.000.00TOTAL CALCULATED AMPSCONN. KVATOTAL KVA(50%>10)(100%)(125%)(125%)RECEPTACLESOTHER MOTORSLARGEST MOTORLIGHTINGCALC. KVAHEATINGCONTINUOUSNONCOIN/DIVERSEKITCHEN EQUIPNONCONTINUOUS(100%)(125%)(100%)TOTAL CONNECTED LOAD (KVA)NOTES:METERED DEMAND(125%)COOLINGABCTOTAL CONNECTED LOAD (AMPS)ABC0.00(100%)0.000.000.000.000.000.000.000.000.000.00COMPUTER0.000.000.000.000.000.000.000.000.000.000.000.00(N/A)(N/A)0.000.000.000.000.00(N/A)0.000.000.000.000.000.00SPARESPARESPARESPARESPARESPARESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPARESPARESPARESPARESPARESPARESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACENEUTRAL:BUS AMPS:VOLTS:AIC:MAIN OCPD:LUGS:FED FROM:MOUNTING:LOCATION:CCTNO.NO.CCTCIRCUIT DESCRIPTIONCIRCUIT DESCRIPTIONPANEL:SEE ONE-LINE DIAGRAMENCLOSURE:KVA LOADBCCCTOCPDNOTESACCTOCPDNOTESL14ASEE PLANSSURFACE208Y/120V 3P 4W20022,000MLOFEEDTHRU100%NEMA 12115/20.721.3720/134 |0.601.3720/16520/120/11.201.008720/10.361.3320/191020/10.720.3620/1121120/120/10.720.36141320/10.720.3620/1151620/11.080.3620/1181720/120/10.900.36201920/10.721.0820/1212220/10.720.7220/1242320/120/10.720.72262520/10.720.7220/1272820/11.080.3620/1302920/120/10.700.36323120/10.410.2020/1333420/10.000.0020/1363520/120/10.000.00383720/10.000.0020/1394020/10.000.0020/1424120/120/10.000.00TOTAL CALCULATED AMPSCONN. KVATOTAL KVA(50%>10)(100%)(125%)(125%)RECEPTACLESOTHER MOTORSLARGEST MOTORLIGHTINGCALC. KVAHEATINGCONTINUOUSNONCOIN/DIVERSEKITCHEN EQUIPNONCONTINUOUS(100%)(125%)(100%)TOTAL CONNECTED LOAD (KVA)NOTES:METERED DEMAND(125%)COOLINGABCTOTAL CONNECTED LOAD (AMPS)ABC23.13(100%)0.0012.112.372.131.380.0014.222.371.711.11COMPUTER60.2921.721.000.002.720.000.001.000.002.720.000.00(N/A)(N/A)0.000.0064.190.000.00(N/A)8.717.377.0461.7958.6772.90FCU-215, FCU-216, FCU-217EH-12ADA DOOR MOTORRECRECRECRECRECRECRECRECRECRECRECDOOR MAG HOLDSPARESPARESPARESPARESPAREDF-2PRINT-1COPY-1RECRECRECRECRECRECRECRECRECRECRECCASEWORK LIGHTING CONNECTION, SWEET SHOP SIGNAGELTGSPARESPARESPARESPARESPARENEUTRAL:BUS AMPS:VOLTS:AIC:MAIN OCPD:LUGS:FED FROM:MOUNTING:LOCATION:CCTNO.NO.CCTCIRCUIT DESCRIPTIONCIRCUIT DESCRIPTIONPANEL:SEE ONE-LINE DIAGRAMENCLOSURE:KVA LOADBCCCTOCPDNOTESACCTOCPDNOTESL14BSEE PLANSSURFACE208Y/120V 3P 4W20022,000MLOSTANDARD100%NEMA 12120/10.000.0020/13420/10.000.0020/16520/120/10.000.008720/10.000.0020/191020/10.000.0020/1121120/120/10.000.001413-/10.000.00-/11516-/10.000.00-/11817-/1-/10.000.002019-/10.000.00-/12122-/10.000.00-/12423-/1-/10.000.002625-/10.000.00-/12728-/10.000.00-/13029-/1-/10.000.003231-/10.000.00-/13334-/10.000.00-/13635-/1-/10.000.003837-/10.000.00-/13940-/10.000.00-/14241-/1-/10.000.00TOTAL CALCULATED AMPSCONN. KVATOTAL KVA(50%>10)(100%)(125%)(125%)RECEPTACLESOTHER MOTORSLARGEST MOTORLIGHTINGCALC. KVAHEATINGCONTINUOUSNONCOIN/DIVERSEKITCHEN EQUIPNONCONTINUOUS(100%)(125%)(100%)TOTAL CONNECTED LOAD (KVA)NOTES:METERED DEMAND(125%)COOLINGABCTOTAL CONNECTED LOAD (AMPS)ABC0.00(100%)0.000.000.000.000.000.000.000.000.000.00COMPUTER0.000.000.000.000.000.000.000.000.000.000.000.00(N/A)(N/A)0.000.000.000.000.00(N/A)0.000.000.000.000.000.00SPARESPARESPARESPARESPARESPARESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPARESPARESPARESPARESPARESPARESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACENEUTRAL:BUS AMPS:VOLTS:AIC:MAIN OCPD:LUGS:FED FROM:MOUNTING:LOCATION:CCTNO.NO.CCTCIRCUIT DESCRIPTIONCIRCUIT DESCRIPTIONPANEL:SEE ONE-LINE DIAGRAMENCLOSURE:KVA LOADBCCCTOCPDNOTESACCTOCPDNOTESL12SEE PLANSSURFACE208Y/120V 3P 4W20042,000MLOSTANDARD100%NEMA 12120/12.820.6035/23420/12.820.60 |6520/120/10.240.608720/11.800.6020/191015/20.580.8320/11211 |20/10.120.83141320/11.000.2020/1151620/10.920.2015/2181720/1 |0.920.04201920/10.541.2020/1212220/10.900.5420/1242320/120/11.080.72262520/11.080.9020/1272820/10.901.0820/1302920/120/11.080.72323120/10.900.7220/1333420/10.360.3020/1363520/120/10.170.54383720/10.100.2020/1394020/10.200.3020/1424120/120/10.000.10444320/10.000.0020/1454620/10.000.0020/1484720/120/10.000.00504920/10.000.0020/1515220/10.000.0020/1545320/120/10.000.00TOTAL CALCULATED AMPSCONN. KVATOTAL KVA(50%>10)(100%)(125%)(125%)RECEPTACLESOTHER MOTORSLARGEST MOTORLIGHTINGCALC. KVAHEATINGCONTINUOUSNONCOIN/DIVERSEKITCHEN EQUIPNONCONTINUOUS(100%)(125%)(100%)TOTAL CONNECTED LOAD (KVA)NOTES:METERED DEMAND(125%)COOLINGABCTOTAL CONNECTED LOAD (AMPS)ABC30.33(100%)0.0011.036.207.050.250.0012.066.205.640.20COMPUTER85.6030.843.640.302.300.000.003.640.382.300.000.00(N/A)(N/A)0.000.0084.200.000.00(N/A)12.6610.527.1587.8360.17106.34WH-1WH-2WH-3WH-4BCU-1, FCU-211, FCU-212FIRE SMOKE DAMPERDRIVEWAY SIGNFP-1, FP-2, FP-3DRIVEWAY SIGN, MONUMENT SIGNRECRECRECRECRECRECGATEWAYRECMOTORIZED SHADESFIRE ALARM SPRINKLER BELLDOOR MAG HOLDSPARESPARESPARESPARESPARESPAREUH-01DH-01WS-01DHWP-1DHWP-2EH-11FCU-213, FCU-214, FCU-311RECRECRECRECRECRECRECRECLTGLTG CONTROL ANTENNA PSFIRE ALARM CONTROL PANELSPARESPARESPARESPARESPARESPARESPARE32 MERCHANT STREET, SUITE 208HONOLULU, HI 96813808-352-5299OWNER:HOMEWOOD SUITES by HILTON SPOKANE VALLEY, WA 13515 E. Carlisle Avenue Spokane Valley, WA 99216FSC PROJECT NO. 21012PERMITDOCUMENTSMay 31, 2024GL8 MirabeauPoint, LLCTMK:PID: 45101.0401 10909 E. Pierce LaneSpokane, WA 99206(509) 919-0901Revision ScheduleNumber Description Date5915 S REGAL STREETSUITE 201SPOKANE, WA 99223PH: 509.473.9218Kelly@kwrllc.comwww.kwrllc.com5/30/2024 1:27:33 PMSTATE OF WASHINGTONREGISTERED PROFESSIONAL ENG INEER48350 KELLY A N DREW WATERMAN05.31.24PANEL SCHEDULESE-606(SEE NOTE 'a') a.PANEL SCHEDULE SHOWN FOR BREAKER QUANTITIES AND PHASE / LOADBALANCING. SEE ALTERNATE CALCULATIONS ON SHEET E-603 FOR CALCULATEDLOAD BASED UPON NEC ALLOWABLE DEMAND FACTORS.a. PANEL SCHEDULE SHOWN FOR BREAKER QUANTITIES AND PHASE / LOADBALANCING. SEE ALTERNATE CALCULATIONS ON SHEET E-603 FOR CALCULATEDLOAD BASED UPON NEC ALLOWABLE DEMAND FACTORS.a. PANEL SCHEDULE SHOWN FOR BREAKER QUANTITIES AND PHASE / LOADBALANCING. SEE ALTERNATE CALCULATIONS ON SHEET E-603 FOR CALCULATEDLOAD BASED UPON NEC ALLOWABLE DEMAND FACTORS.a. PANEL SCHEDULE SHOWN FOR BREAKER QUANTITIES AND PHASE / LOADBALANCING. SEE ALTERNATE CALCULATIONS ON SHEET E-603 FOR CALCULATEDLOAD BASED UPON NEC ALLOWABLE DEMAND FACTORS.a. PROVIDE LOCKABLE CIRCUIT BREAKER.b. PROVIDE GFCI CIRCUIT BREAKER WITH 6mA TRIP.c. PROVIDE CIRCUIT BREAKER WITH RED HANDLE.aaccNEUTRAL:BUS AMPS:VOLTS:AIC:MAIN OCPD:LUGS:FED FROM:MOUNTING:LOCATION:CCTNO.NO.CCTCIRCUIT DESCRIPTIONCIRCUIT DESCRIPTIONPANEL:SEE ONE-LINE DIAGRAMENCLOSURE:KVA LOADBCCCTOCPDNOTESACCTOCPDNOTESL24SEE PLANSSURFACE208Y/120V 3P 4W20010,000MLOSTANDARD100%NEMA 121100/25.725.80100/234 |5.595.41 |65100/2100/25.725.8087 |5.595.41 |910100/25.805.72100/21211 | |5.775.591413100/25.805.72100/21516 |5.415.59 |1817-/1-/10.000.002019-/10.000.00-/12122-/10.000.00-/12423-/1-/10.000.002625-/10.000.00-/12728-/10.000.00-/13029-/1-/10.000.00TOTAL CALCULATED AMPSCONN. KVATOTAL KVA(50%>10)(100%)(125%)(125%)RECEPTACLESOTHER MOTORSLARGEST MOTORLIGHTINGCALC. KVAHEATINGCONTINUOUSNONCOIN/DIVERSEKITCHEN EQUIPNONCONTINUOUS(100%)(125%)(100%)TOTAL CONNECTED LOAD (KVA)NOTES:METERED DEMAND(125%)COOLINGABCTOTAL CONNECTED LOAD (AMPS)ABC90.40(100%)0.0012.740.000.005.920.0015.480.000.004.74COMPUTER246.6188.840.000.0070.180.000.000.000.0070.180.000.00(N/A)(N/A)0.000.00250.930.000.00(N/A)34.0333.5022.87280.54 190.51284.88PANEL B-223PANEL B-225PANEL A-227PANEL A-229SPACESPACESPACESPACESPACESPACESPACEPANEL A-231PANEL A-233PANEL F-235PANEL B-237SPACESPACESPACESPACESPACESPACESPACENEUTRAL:BUS AMPS:VOLTS:AIC:MAIN OCPD:LUGS:FED FROM:MOUNTING:LOCATION:CCTNO.NO.CCTCIRCUIT DESCRIPTIONCIRCUIT DESCRIPTIONPANEL:SEE ONE-LINE DIAGRAMENCLOSURE:KVA LOADBCCCTOCPDNOTESACCTOCPDNOTESL25SEE PLANSSURFACE208Y/120V 3P 4W20010,000MLOSTANDARD100%NEMA 121100/25.805.80100/234 |5.415.77 |65100/2100/25.725.8087 |5.595.41 |910100/25.805.72100/21211 | |5.775.591413-/15.800.00100/21516-/15.760.00 |1817-/1-/10.000.002019-/10.000.00-/12122-/10.000.00-/12423-/1-/10.000.002625-/10.000.00-/12728-/10.000.00-/13029-/1-/10.000.00TOTAL CALCULATED AMPSCONN. KVATOTAL KVA(50%>10)(100%)(125%)(125%)RECEPTACLESOTHER MOTORSLARGEST MOTORLIGHTINGCALC. KVAHEATINGCONTINUOUSNONCOIN/DIVERSEKITCHEN EQUIPNONCONTINUOUS(100%)(125%)(100%)TOTAL CONNECTED LOAD (KVA)NOTES:METERED DEMAND(125%)COOLINGABCTOTAL CONNECTED LOAD (AMPS)ABC79.71(100%)0.0011.930.000.005.340.0013.860.000.004.27COMPUTER218.8678.850.000.0061.580.000.000.000.0061.580.000.00(N/A)(N/A)0.000.00221.260.000.00(N/A)28.3928.4522.87237.39 190.51236.96PANEL F-224PANEL B-226PANEL A-228SPACESPACESPACESPACESPACESPACESPACESPACESPACEPANEL B-230PANEL A-234PANEL F-236PANEL D-238SPACESPACESPACESPACESPACESPACESPACENEUTRAL:BUS AMPS:VOLTS:AIC:MAIN OCPD:LUGS:FED FROM:MOUNTING:LOCATION:CCTNO.NO.CCTCIRCUIT DESCRIPTIONCIRCUIT DESCRIPTIONPANEL:SEE ONE-LINE DIAGRAMENCLOSURE:KVA LOADBCCCTOCPDNOTESACCTOCPDNOTESL21SEE PLANSSURFACE208Y/120V 3P 4W10022,000MLOSTANDARD100%NEMA 12115/21.000.6120/134 |1.000.6120/16520/120/10.200.728720/11.440.3620/291020/11.441.08 |121120/120/10.620.36141320/10.300.3620/1151620/10.000.3620/1181720/120/10.000.36201920/10.000.3620/1212220/10.000.7220/1242320/120/10.000.72262520/10.001.0820/1272820/10.000.2020/1302920/120/10.000.183231-/10.000.0020/13334-/10.000.0020/13635-/120/10.000.003837-/10.000.0020/13940-/10.000.00-/14241-/1-/10.000.00TOTAL CALCULATED AMPSCONN. KVATOTAL KVA(50%>10)(100%)(125%)(125%)RECEPTACLESOTHER MOTORSLARGEST MOTORLIGHTINGCALC. KVAHEATINGCONTINUOUSNONCOIN/DIVERSEKITCHEN EQUIPNONCONTINUOUS(100%)(125%)(100%)TOTAL CONNECTED LOAD (KVA)NOTES:METERED DEMAND(125%)COOLINGABCTOTAL CONNECTED LOAD (AMPS)ABC14.08(100%)0.006.661.843.600.380.006.661.842.880.30COMPUTER41.3014.882.000.000.400.000.002.000.000.400.000.00(N/A)(N/A)0.000.0039.090.000.00(N/A)5.515.413.1646.1526.3346.96FCU-321, FCU-322, FCU-323, FCU-324, FCU-325, FCU-326, FCU-421RECRECRECRECRECRECRECRECRECRECRECDOOR MAG HOLDRECSPACESPACESPACESPACESPACESPACEEH-21EH-22FIRE SMOKE DAMPEREF-01DAMPER ACTUATOR, EF-02LTGSPARESPARESPARESPARESPARESPARESPARESPARESPARESPARESPARESPARESPACESPACENEUTRAL:BUS AMPS:VOLTS:AIC:MAIN OCPD:LUGS:FED FROM:MOUNTING:LOCATION:CCTNO.NO.CCTCIRCUIT DESCRIPTIONCIRCUIT DESCRIPTIONPANEL:SEE ONE-LINE DIAGRAMENCLOSURE:KVA LOADBCCCTOCPDNOTESACCTOCPDNOTESL22SEE PLANSSURFACE208Y/120V 3P 4W20022,000MLOSTANDARD100%NEMA 121125/25.8011.58100/234 |5.7712.57 |65100/2100/25.805.8087 |5.415.41 |910100/25.805.72100/21211 | |5.415.591413100/25.805.80100/21516 |5.415.77 |1817-/1-/10.000.002019-/10.000.00-/12122-/10.000.00-/12423-/1-/10.000.002625-/10.000.00-/12728-/10.000.00-/13029-/1-/10.000.00TOTAL CALCULATED AMPSCONN. KVATOTAL KVA(50%>10)(100%)(125%)(125%)RECEPTACLESOTHER MOTORSLARGEST MOTORLIGHTINGCALC. KVAHEATINGCONTINUOUSNONCOIN/DIVERSEKITCHEN EQUIPNONCONTINUOUS(100%)(125%)(100%)TOTAL CONNECTED LOAD (KVA)NOTES:METERED DEMAND(125%)COOLINGABCTOTAL CONNECTED LOAD (AMPS)ABC103.42(100%)0.0012.740.000.006.480.0015.480.000.005.18COMPUTER283.05101.970.000.0082.760.000.000.000.0082.760.000.00(N/A)(N/A)0.000.00287.060.000.00(N/A)39.7941.0322.59346.23 188.21336.06PANEL E-202PANEL B-204PANEL A-208PANEL F-210SPACESPACESPACESPACESPACESPACESPACEPANEL F-212PANEL B-214PANEL B-216PANEL B-218SPACESPACESPACESPACESPACESPACESPACENEUTRAL:BUS AMPS:VOLTS:AIC:MAIN OCPD:LUGS:FED FROM:MOUNTING:LOCATION:CCTNO.NO.CCTCIRCUIT DESCRIPTIONCIRCUIT DESCRIPTIONPANEL:SEE ONE-LINE DIAGRAMENCLOSURE:KVA LOADBCCCTOCPDNOTESACCTOCPDNOTESL23SEE PLANSSURFACE208Y/120V 3P 4W20022,000MLOSTANDARD100%NEMA 121125/25.8011.58100/234 |5.4112.57 |65100/2100/25.805.7887 |5.415.76 |910100/25.805.72100/21211 | |5.415.591413-/15.800.00100/21516-/15.770.00 |1817-/1-/10.000.002019-/10.000.00-/12122-/10.000.00-/12423-/1-/10.000.002625-/10.000.00-/12728-/10.000.00-/13029-/1-/10.000.00TOTAL CALCULATED AMPSCONN. KVATOTAL KVA(50%>10)(100%)(125%)(125%)RECEPTACLESOTHER MOTORSLARGEST MOTORLIGHTINGCALC. KVAHEATINGCONTINUOUSNONCOIN/DIVERSEKITCHEN EQUIPNONCONTINUOUS(100%)(125%)(100%)TOTAL CONNECTED LOAD (KVA)NOTES:METERED DEMAND(125%)COOLINGABCTOTAL CONNECTED LOAD (AMPS)ABC92.18(100%)0.0011.750.000.005.650.0013.500.000.004.52COMPUTER254.1491.560.000.0074.150.000.000.000.0074.150.000.00(N/A)(N/A)0.000.00255.850.000.00(N/A)34.3435.2622.57296.60 188.01289.01PANEL E-201PANEL C-203PANEL A-205SPACESPACESPACESPACESPACESPACESPACESPACESPACEPANEL B-219PANEL B-221PANEL B-220PANEL F-222SPACESPACESPACESPACESPACESPACESPACE32 MERCHANT STREET, SUITE 208HONOLULU, HI 96813808-352-5299OWNER:HOMEWOOD SUITES by HILTON SPOKANE VALLEY, WA 13515 E. Carlisle Avenue Spokane Valley, WA 99216FSC PROJECT NO. 21012PERMITDOCUMENTSMay 31, 2024GL8 MirabeauPoint, LLCTMK:PID: 45101.0401 10909 E. Pierce LaneSpokane, WA 99206(509) 919-0901Revision ScheduleNumber Description Date5915 S REGAL STREETSUITE 201SPOKANE, WA 99223PH: 509.473.9218Kelly@kwrllc.comwww.kwrllc.com5/30/2024 1:27:38 PMSTATE OF WASHINGTONREGISTERED PROFESSIONAL ENG INEER48350 KELLY A N DREW WATERMAN05.31.24PANEL SCHEDULESE-607(SEE NOTE 'a')(SEE NOTE 'a')(SEE NOTE 'a')(SEE NOTE 'a') a.PANEL SCHEDULE SHOWN FOR BREAKER QUANTITIES AND PHASE / LOADBALANCING. SEE ALTERNATE CALCULATIONS ON SHEET E-603 FOR CALCULATEDLOAD BASED UPON NEC ALLOWABLE DEMAND FACTORS.a. PANEL SCHEDULE SHOWN FOR BREAKER QUANTITIES AND PHASE / LOADBALANCING. SEE ALTERNATE CALCULATIONS ON SHEET E-603 FOR CALCULATEDLOAD BASED UPON NEC ALLOWABLE DEMAND FACTORS.a. PANEL SCHEDULE SHOWN FOR BREAKER QUANTITIES AND PHASE / LOADBALANCING. SEE ALTERNATE CALCULATIONS ON SHEET E-603 FOR CALCULATEDLOAD BASED UPON NEC ALLOWABLE DEMAND FACTORS.a. PANEL SCHEDULE SHOWN FOR BREAKER QUANTITIES AND PHASE / LOADBALANCING. SEE ALTERNATE CALCULATIONS ON SHEET E-603 FOR CALCULATEDLOAD BASED UPON NEC ALLOWABLE DEMAND FACTORS.a. PROVIDE LOCKABLE CIRCUIT BREAKER.b. PROVIDE GFCI CIRCUIT BREAKER WITH 6mA TRIP.c. PROVIDE CIRCUIT BREAKER WITH RED HANDLE.aaccNEUTRAL:BUS AMPS:VOLTS:AIC:MAIN OCPD:LUGS:FED FROM:MOUNTING:LOCATION:CCTNO.NO.CCTCIRCUIT DESCRIPTIONCIRCUIT DESCRIPTIONPANEL:SEE ONE-LINE DIAGRAMENCLOSURE:KVA LOADBCCCTOCPDNOTESACCTOCPDNOTESL31SEE PLANSSURFACE208Y/120V 3P 4W10022,000MLOSTANDARD100%NEMA 12115/21.000.4520/134 |1.000.4520/16520/120/10.201.088720/10.300.3620/191020/10.201.0820/1121120/120/10.000.90141320/10.000.0020/1151620/10.000.0020/1181720/120/10.000.00201920/10.000.0020/1212220/10.000.0020/1242320/1-/10.000.002625-/10.000.00-/12728-/10.000.00-/13029-/1-/10.000.003231-/10.000.00-/13334-/10.000.00-/13635-/1-/10.000.003837-/10.000.00-/13940-/10.000.00-/14241-/1-/10.000.004443-/10.000.00-/14546-/10.000.00-/14847-/1-/10.000.005049-/10.000.00-/15152-/10.000.00-/15453-/1-/10.000.00TOTAL CALCULATED AMPSCONN. KVATOTAL KVA(50%>10)(100%)(125%)(125%)RECEPTACLESOTHER MOTORSLARGEST MOTORLIGHTINGCALC. KVAHEATINGCONTINUOUSNONCOIN/DIVERSEKITCHEN EQUIPNONCONTINUOUS(100%)(125%)(100%)TOTAL CONNECTED LOAD (KVA)NOTES:METERED DEMAND(125%)COOLINGABCTOTAL CONNECTED LOAD (AMPS)ABC7.02(100%)0.003.420.740.460.380.003.420.740.360.30COMPUTER19.957.192.000.000.200.000.002.000.000.200.000.00(N/A)(N/A)0.000.0019.490.000.00(N/A)2.112.732.1822.8518.1717.72BCU-2, FCU-331, FCU-332, FCU-333, FCU-334, FCU-335RECRECRECRECSPARESPARESPARESPARESPARESPARESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACEEH-31EH-32FIRE SMOKE DAMPERLTGDOOR MAG HOLDSPARESPARESPARESPARESPARESPARESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACENEUTRAL:BUS AMPS:VOLTS:AIC:MAIN OCPD:LUGS:FED FROM:MOUNTING:LOCATION:CCTNO.NO.CCTCIRCUIT DESCRIPTIONCIRCUIT DESCRIPTIONPANEL:SEE ONE-LINE DIAGRAMENCLOSURE:KVA LOADBCCCTOCPDNOTESACCTOCPDNOTESL32SEE PLANSSURFACE208Y/120V 3P 4W20022,000MLOSTANDARD100%NEMA 121125/25.8011.58100/234 |5.7712.57 |65100/2100/25.805.8087 |5.415.41 |910100/25.805.72100/21211 | |5.415.591413100/25.805.80100/21516 |5.415.77 |1817-/1-/10.000.002019-/10.000.00-/12122-/10.000.00-/12423-/1-/10.000.002625-/10.000.00-/12728-/10.000.00-/13029-/1-/10.000.00TOTAL CALCULATED AMPSCONN. KVATOTAL KVA(50%>10)(100%)(125%)(125%)RECEPTACLESOTHER MOTORSLARGEST MOTORLIGHTINGCALC. KVAHEATINGCONTINUOUSNONCOIN/DIVERSEKITCHEN EQUIPNONCONTINUOUS(100%)(125%)(100%)TOTAL CONNECTED LOAD (KVA)NOTES:METERED DEMAND(125%)COOLINGABCTOTAL CONNECTED LOAD (AMPS)ABC103.42(100%)0.0012.740.000.006.480.0015.480.000.005.18COMPUTER283.05101.970.000.0082.760.000.000.000.0082.760.000.00(N/A)(N/A)0.000.00287.060.000.00(N/A)39.7941.0322.59346.23 188.21336.06PANEL E-302PANEL B-304PANEL A-308PANEL F-310SPACESPACESPACESPACESPACESPACESPACEPANEL F-312PANEL B-314PANEL B-316PANEL B-318SPACESPACESPACESPACESPACESPACESPACENEUTRAL:BUS AMPS:VOLTS:AIC:MAIN OCPD:LUGS:FED FROM:MOUNTING:LOCATION:CCTNO.NO.CCTCIRCUIT DESCRIPTIONCIRCUIT DESCRIPTIONPANEL:SEE ONE-LINE DIAGRAMENCLOSURE:KVA LOADBCCCTOCPDNOTESACCTOCPDNOTESL33SEE PLANSSURFACE208Y/120V 3P 4W20022,000MLOSTANDARD100%NEMA 121125/25.8011.58100/234 |5.4113.50 |65100/2100/25.805.7287 |5.415.59 |910100/25.805.72100/21211 | |5.415.591413100/25.805.72100/21516 |5.775.59 |1817-/1-/10.000.002019-/10.000.00-/12122-/10.000.00-/12423-/1-/10.000.002625-/10.000.00-/12728-/10.000.00-/13029-/1-/10.000.00TOTAL CALCULATED AMPSCONN. KVATOTAL KVA(50%>10)(100%)(125%)(125%)RECEPTACLESOTHER MOTORSLARGEST MOTORLIGHTINGCALC. KVAHEATINGCONTINUOUSNONCOIN/DIVERSEKITCHEN EQUIPNONCONTINUOUS(100%)(125%)(100%)TOTAL CONNECTED LOAD (KVA)NOTES:METERED DEMAND(125%)COOLINGABCTOTAL CONNECTED LOAD (AMPS)ABC104.18(100%)0.0012.920.000.006.270.0015.840.000.005.01COMPUTER284.54102.510.000.0083.330.000.000.000.0083.330.000.00(N/A)(N/A)0.000.00289.170.000.00(N/A)39.8941.7822.51352.40 187.51336.85PANEL G-301PANEL A-303PANEL A-305PANEL A-307SPACESPACESPACESPACESPACESPACESPACEPANEL B-319PANEL B-321PANEL B-320PANEL F-322SPACESPACESPACESPACESPACESPACESPACENEUTRAL:BUS AMPS:VOLTS:AIC:MAIN OCPD:LUGS:FED FROM:MOUNTING:LOCATION:CCTNO.NO.CCTCIRCUIT DESCRIPTIONCIRCUIT DESCRIPTIONPANEL:SEE ONE-LINE DIAGRAMENCLOSURE:KVA LOADBCCCTOCPDNOTESACCTOCPDNOTESL34SEE PLANSSURFACE208Y/120V 3P 4W20010,000MLOSTANDARD100%NEMA 121100/25.725.80100/234 |5.595.41 |65100/2100/25.725.8087 |5.595.41 |910100/25.805.72100/21211 | |5.775.591413100/25.805.72100/21516 |5.415.59 |1817-/1-/10.000.002019-/10.000.00-/12122-/10.000.00-/12423-/1-/10.000.002625-/10.000.00-/12728-/10.000.00-/13029-/1-/10.000.00TOTAL CALCULATED AMPSCONN. KVATOTAL KVA(50%>10)(100%)(125%)(125%)RECEPTACLESOTHER MOTORSLARGEST MOTORLIGHTINGCALC. KVAHEATINGCONTINUOUSNONCOIN/DIVERSEKITCHEN EQUIPNONCONTINUOUS(100%)(125%)(100%)TOTAL CONNECTED LOAD (KVA)NOTES:METERED DEMAND(125%)COOLINGABCTOTAL CONNECTED LOAD (AMPS)ABC90.40(100%)0.0012.740.000.005.920.0015.480.000.004.74COMPUTER246.6188.840.000.0070.180.000.000.000.0070.180.000.00(N/A)(N/A)0.000.00250.930.000.00(N/A)34.0333.5022.87280.54 190.51284.88PANEL B-323PANEL B-325PANEL A-327PANEL A-329SPACESPACESPACESPACESPACESPACESPACEPANEL A-331PANEL A-333PANEL F-335PANEL B-337SPACESPACESPACESPACESPACESPACESPACENEUTRAL:BUS AMPS:VOLTS:AIC:MAIN OCPD:LUGS:FED FROM:MOUNTING:LOCATION:CCTNO.NO.CCTCIRCUIT DESCRIPTIONCIRCUIT DESCRIPTIONPANEL:SEE ONE-LINE DIAGRAMENCLOSURE:KVA LOADBCCCTOCPDNOTESACCTOCPDNOTESL35SEE PLANSSURFACE208Y/120V 3P 4W20010,000MLOSTANDARD100%NEMA 121100/25.725.80100/234 |5.595.77 |65100/2100/25.805.8087 |5.775.41 |910100/25.805.72100/21211 | |5.415.591413100/20.005.80-/11516 |0.005.41-/11817-/1-/10.000.002019-/10.000.00-/12122-/10.000.00-/12423-/1-/10.000.002625-/10.000.00-/12728-/10.000.00-/13029-/1-/10.000.00TOTAL CALCULATED AMPSCONN. KVATOTAL KVA(50%>10)(100%)(125%)(125%)RECEPTACLESOTHER MOTORSLARGEST MOTORLIGHTINGCALC. KVAHEATINGCONTINUOUSNONCOIN/DIVERSEKITCHEN EQUIPNONCONTINUOUS(100%)(125%)(100%)TOTAL CONNECTED LOAD (KVA)NOTES:METERED DEMAND(125%)COOLINGABCTOTAL CONNECTED LOAD (AMPS)ABC79.36(100%)0.0011.840.000.005.340.0013.680.000.004.27COMPUTER218.1478.590.000.0061.410.000.000.000.0061.410.000.00(N/A)(N/A)0.000.00220.280.000.00(N/A)28.4928.2822.59235.98 188.21237.76PANEL F-324PANEL B-326PANEL A-328PANEL B-330SPACESPACESPACESPACESPACESPACESPACEPANEL A-334PANEL F-336PANEL B-338SPACESPACESPACESPACESPACESPACESPACESPACESPACE32 MERCHANT STREET, SUITE 208HONOLULU, HI 96813808-352-5299OWNER:HOMEWOOD SUITES by HILTON SPOKANE VALLEY, WA 13515 E. Carlisle Avenue Spokane Valley, WA 99216FSC PROJECT NO. 21012PERMITDOCUMENTSMay 31, 2024GL8 MirabeauPoint, LLCTMK:PID: 45101.0401 10909 E. Pierce LaneSpokane, WA 99206(509) 919-0901Revision ScheduleNumber Description Date5915 S REGAL STREETSUITE 201SPOKANE, WA 99223PH: 509.473.9218Kelly@kwrllc.comwww.kwrllc.com5/30/2024 1:27:43 PMSTATE OF WASHINGTONREGISTERED PROFESSIONAL ENG INEER48350 KELLY A N DREW WATERMAN05.31.24PANEL SCHEDULESE-608(SEE NOTE 'a')(SEE NOTE 'a')(SEE NOTE 'a')(SEE NOTE 'a') a.PANEL SCHEDULE SHOWN FOR BREAKER QUANTITIES AND PHASE / LOADBALANCING. SEE ALTERNATE CALCULATIONS ON SHEET E-603 FOR CALCULATEDLOAD BASED UPON NEC ALLOWABLE DEMAND FACTORS.a. PANEL SCHEDULE SHOWN FOR BREAKER QUANTITIES AND PHASE / LOADBALANCING. SEE ALTERNATE CALCULATIONS ON SHEET E-603 FOR CALCULATEDLOAD BASED UPON NEC ALLOWABLE DEMAND FACTORS.a. PANEL SCHEDULE SHOWN FOR BREAKER QUANTITIES AND PHASE / LOADBALANCING. SEE ALTERNATE CALCULATIONS ON SHEET E-603 FOR CALCULATEDLOAD BASED UPON NEC ALLOWABLE DEMAND FACTORS.a. PANEL SCHEDULE SHOWN FOR BREAKER QUANTITIES AND PHASE / LOADBALANCING. SEE ALTERNATE CALCULATIONS ON SHEET E-603 FOR CALCULATEDLOAD BASED UPON NEC ALLOWABLE DEMAND FACTORS.a. PROVIDE LOCKABLE CIRCUIT BREAKER.b. PROVIDE GFCI CIRCUIT BREAKER WITH 6mA TRIP.c. PROVIDE CIRCUIT BREAKER WITH RED HANDLE.aacccNEUTRAL:BUS AMPS:VOLTS:AIC:MAIN OCPD:LUGS:FED FROM:MOUNTING:LOCATION:CCTNO.NO.CCTCIRCUIT DESCRIPTIONCIRCUIT DESCRIPTIONPANEL:SEE ONE-LINE DIAGRAMENCLOSURE:KVA LOADBCCCTOCPDNOTESACCTOCPDNOTESL42SEE PLANSSURFACE208Y/120V 3P 4W20022,000MLOSTANDARD100%NEMA 121125/25.8011.58100/234 |6.3212.57 |65100/2100/25.805.8087 |5.415.41 |910100/25.805.72100/21211 | |5.415.591413100/25.805.80100/21516 |5.415.77 |1817-/1-/10.000.002019-/10.000.00-/12122-/10.000.00-/12423-/1-/10.000.002625-/10.000.00-/12728-/10.000.00-/13029-/1-/10.000.00TOTAL CALCULATED AMPSCONN. KVATOTAL KVA(50%>10)(100%)(125%)(125%)RECEPTACLESOTHER MOTORSLARGEST MOTORLIGHTINGCALC. KVAHEATINGCONTINUOUSNONCOIN/DIVERSEKITCHEN EQUIPNONCONTINUOUS(100%)(125%)(100%)TOTAL CONNECTED LOAD (KVA)NOTES:METERED DEMAND(125%)COOLINGABCTOTAL CONNECTED LOAD (AMPS)ABC103.97(100%)0.0012.830.000.006.480.0015.660.000.005.18COMPUTER284.32102.430.000.0083.130.000.000.000.0083.130.000.00(N/A)(N/A)0.000.00288.580.000.00(N/A)39.7941.5822.59350.75 188.21336.06PANEL E-402PANEL B-404PANEL A-408PANEL F-410SPACESPACESPACESPACESPACESPACESPACEPANEL H-412PANEL B-414PANEL B-416PANEL B-418SPACESPACESPACESPACESPACESPACESPACENEUTRAL:BUS AMPS:VOLTS:AIC:MAIN OCPD:LUGS:FED FROM:MOUNTING:LOCATION:CCTNO.NO.CCTCIRCUIT DESCRIPTIONCIRCUIT DESCRIPTIONPANEL:SEE ONE-LINE DIAGRAMENCLOSURE:KVA LOADBCCCTOCPDNOTESACCTOCPDNOTESL43SEE PLANSSURFACE208Y/120V 3P 4W20022,000MLOSTANDARD100%NEMA 121125/25.8011.58100/234 |5.4112.57 |65100/2100/25.805.7287 |5.415.59 |910100/25.805.72100/21211 | |5.415.591413100/25.805.72100/21516 |5.775.59 |1817-/1-/10.000.002019-/10.000.00-/12122-/10.000.00-/12423-/1-/10.000.002625-/10.000.00-/12728-/10.000.00-/13029-/1-/10.000.00TOTAL CALCULATED AMPSCONN. KVATOTAL KVA(50%>10)(100%)(125%)(125%)RECEPTACLESOTHER MOTORSLARGEST MOTORLIGHTINGCALC. KVAHEATINGCONTINUOUSNONCOIN/DIVERSEKITCHEN EQUIPNONCONTINUOUS(100%)(125%)(100%)TOTAL CONNECTED LOAD (KVA)NOTES:METERED DEMAND(125%)COOLINGABCTOTAL CONNECTED LOAD (AMPS)ABC103.25(100%)0.0012.740.000.006.270.0015.480.000.005.01COMPUTER282.46101.760.000.0082.760.000.000.000.0082.760.000.00(N/A)(N/A)0.000.00286.590.000.00(N/A)39.8940.8522.51344.75 187.51336.85PANEL E-401PANEL A-403PANEL A-405PANEL A-407SPACESPACESPACESPACESPACESPACESPACEPANEL B-419PANEL B-420PANEL B-421PANEL F-422SPACESPACESPACESPACESPACESPACESPACENEUTRAL:BUS AMPS:VOLTS:AIC:MAIN OCPD:LUGS:FED FROM:MOUNTING:LOCATION:CCTNO.NO.CCTCIRCUIT DESCRIPTIONCIRCUIT DESCRIPTIONPANEL:SEE ONE-LINE DIAGRAMENCLOSURE:KVA LOADBCCCTOCPDNOTESACCTOCPDNOTESL44SEE PLANSSURFACE208Y/120V 3P 4W20010,000MLOSTANDARD100%NEMA 121100/25.725.80100/234 |5.595.41 |65100/2100/25.725.8087 |5.595.41 |910100/25.805.72100/21211 | |5.775.591413100/25.805.72100/21516 |5.415.59 |1817-/1-/10.000.002019-/10.000.00-/12122-/10.000.00-/12423-/1-/10.000.002625-/10.000.00-/12728-/10.000.00-/13029-/1-/10.000.00TOTAL CALCULATED AMPSCONN. KVATOTAL KVA(50%>10)(100%)(125%)(125%)RECEPTACLESOTHER MOTORSLARGEST MOTORLIGHTINGCALC. KVAHEATINGCONTINUOUSNONCOIN/DIVERSEKITCHEN EQUIPNONCONTINUOUS(100%)(125%)(100%)TOTAL CONNECTED LOAD (KVA)NOTES:METERED DEMAND(125%)COOLINGABCTOTAL CONNECTED LOAD (AMPS)ABC90.40(100%)0.0012.740.000.005.920.0015.480.000.004.74COMPUTER246.6188.840.000.0070.180.000.000.000.0070.180.000.00(N/A)(N/A)0.000.00250.930.000.00(N/A)34.0333.5022.87280.54 190.51284.88PANEL B-423PANEL B-425PANEL A-427PANEL A-429SPACESPACESPACESPACESPACESPACESPACEPANEL A-431PANEL A-433PANEL F-435PANEL B-437SPACESPACESPACESPACESPACESPACESPACENEUTRAL:BUS AMPS:VOLTS:AIC:MAIN OCPD:LUGS:FED FROM:MOUNTING:LOCATION:CCTNO.NO.CCTCIRCUIT DESCRIPTIONCIRCUIT DESCRIPTIONPANEL:SEE ONE-LINE DIAGRAMENCLOSURE:KVA LOADBCCCTOCPDNOTESACCTOCPDNOTESL45SEE PLANSSURFACE208Y/120V 3P 4W20010,000MLOSTANDARD100%NEMA 121100/25.725.80100/234 |5.595.77 |65100/2100/25.805.8087 |5.775.41 |910100/25.805.72100/21211 | |5.765.591413100/20.005.80-/11516 |0.005.41-/11817-/1-/10.000.002019-/10.000.00-/12122-/10.000.00-/12423-/1-/10.000.002625-/10.000.00-/12728-/10.000.00-/13029-/1-/10.000.00TOTAL CALCULATED AMPSCONN. KVATOTAL KVA(50%>10)(100%)(125%)(125%)RECEPTACLESOTHER MOTORSLARGEST MOTORLIGHTINGCALC. KVAHEATINGCONTINUOUSNONCOIN/DIVERSEKITCHEN EQUIPNONCONTINUOUS(100%)(125%)(100%)TOTAL CONNECTED LOAD (KVA)NOTES:METERED DEMAND(125%)COOLINGABCTOTAL CONNECTED LOAD (AMPS)ABC79.71(100%)0.0011.930.000.005.340.0013.860.000.004.27COMPUTER218.8678.850.000.0061.580.000.000.000.0061.580.000.00(N/A)(N/A)0.000.00221.260.000.00(N/A)28.4928.2822.94235.98 191.13237.76PANEL F-424PANEL B-426PANEL A-428PANEL B-430SPACESPACESPACESPACESPACESPACESPACEPANEL A-434PANEL F-436PANEL D-438SPACESPACESPACESPACESPACESPACESPACESPACESPACENEUTRAL:BUS AMPS:VOLTS:AIC:MAIN OCPD:LUGS:FED FROM:MOUNTING:LOCATION:CCTNO.NO.CCTCIRCUIT DESCRIPTIONCIRCUIT DESCRIPTIONPANEL:SEE ONE-LINE DIAGRAMENCLOSURE:KVA LOADBCCCTOCPDNOTESACCTOCPDNOTESL41SEE PLANSSURFACE208Y/120V 3P 4W10022,000MLOSTANDARD100%NEMA 12115/21.000.2920/134 |1.000.2920/16520/120/10.201.088720/10.300.3620/191020/10.201.0820/1121120/120/10.200.90141320/10.000.0020/1151620/10.000.0020/1181720/120/10.000.00201920/10.000.0020/1212220/10.000.0020/1242320/120/10.000.002625-/10.000.00-/12728-/10.000.00-/13029-/1-/10.000.003231-/10.000.00-/13334-/10.000.00-/13635-/1-/10.000.003837-/10.000.00-/13940-/10.000.00-/14241-/1-/10.000.004443-/10.000.00-/14546-/10.000.00-/14847-/1-/10.000.005049-/10.000.00-/15152-/10.000.00-/15453-/1-/10.000.00TOTAL CALCULATED AMPSCONN. KVATOTAL KVA(50%>10)(100%)(125%)(125%)RECEPTACLESOTHER MOTORSLARGEST MOTORLIGHTINGCALC. KVAHEATINGCONTINUOUSNONCOIN/DIVERSEKITCHEN EQUIPNONCONTINUOUS(100%)(125%)(100%)TOTAL CONNECTED LOAD (KVA)NOTES:METERED DEMAND(125%)COOLINGABCTOTAL CONNECTED LOAD (AMPS)ABC6.89(100%)0.003.420.410.460.380.003.420.410.360.30COMPUTER19.607.062.000.000.400.000.002.000.000.400.000.00(N/A)(N/A)0.000.0019.140.000.00(N/A)1.952.572.3821.4319.8316.28FCU-341, FCU-342, FCU-343, FCU-344, FCU-345RECRECRECRECSPARESPARESPARESPARESPARESPARESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACEEH-41EH-42FIRE SMOKE DAMPERLTGDOOR MAG HOLDFIRE ALARM CONTROL PANELSPARESPARESPARESPARESPARESPARESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACE32 MERCHANT STREET, SUITE 208HONOLULU, HI 96813808-352-5299OWNER:HOMEWOOD SUITES by HILTON SPOKANE VALLEY, WA 13515 E. Carlisle Avenue Spokane Valley, WA 99216FSC PROJECT NO. 21012PERMITDOCUMENTSMay 31, 2024GL8 MirabeauPoint, LLCTMK:PID: 45101.0401 10909 E. Pierce LaneSpokane, WA 99206(509) 919-0901Revision ScheduleNumber Description Date5915 S REGAL STREETSUITE 201SPOKANE, WA 99223PH: 509.473.9218Kelly@kwrllc.comwww.kwrllc.com5/30/2024 1:27:48 PMSTATE OF WASHINGTONREGISTERED PROFESSIONAL ENG INEER48350 KELLY A N DREW WATERMAN05.31.24PANEL SCHEDULESE-609(SEE NOTE 'a')(SEE NOTE 'a')(SEE NOTE 'a')(SEE NOTE 'a') a.PANEL SCHEDULE SHOWN FOR BREAKER QUANTITIES AND PHASE / LOADBALANCING. SEE ALTERNATE CALCULATIONS ON SHEET E-603 FOR CALCULATEDLOAD BASED UPON NEC ALLOWABLE DEMAND FACTORS.a. PANEL SCHEDULE SHOWN FOR BREAKER QUANTITIES AND PHASE / LOADBALANCING. SEE ALTERNATE CALCULATIONS ON SHEET E-603 FOR CALCULATEDLOAD BASED UPON NEC ALLOWABLE DEMAND FACTORS.a. PANEL SCHEDULE SHOWN FOR BREAKER QUANTITIES AND PHASE / LOADBALANCING. SEE ALTERNATE CALCULATIONS ON SHEET E-603 FOR CALCULATEDLOAD BASED UPON NEC ALLOWABLE DEMAND FACTORS.a. PANEL SCHEDULE SHOWN FOR BREAKER QUANTITIES AND PHASE / LOADBALANCING. SEE ALTERNATE CALCULATIONS ON SHEET E-603 FOR CALCULATEDLOAD BASED UPON NEC ALLOWABLE DEMAND FACTORS.a. PROVIDE LOCKABLE CIRCUIT BREAKER.b. PROVIDE GFCI CIRCUIT BREAKER WITH 6mA TRIP.c. PROVIDE CIRCUIT BREAKER WITH RED HANDLE.aaccNEUTRAL:BUS AMPS:VOLTS:AIC:MAIN OCPD:LUGS:FED FROM:MOUNTING:LOCATION:CCTNO.NO.CCTCIRCUIT DESCRIPTIONCIRCUIT DESCRIPTIONPANEL:SEE ONE-LINE DIAGRAMENCLOSURE:KVA LOADBCCCTOCPDNOTESACCTOCPDNOTESL51SEE PLANSSURFACE208Y/120V 3P 4W10022,000MLOSTANDARD100%NEMA 12115/21.000.5920/134 |1.000.5920/16525/320/10.201.3287 |0.721.3220/1910 |1.081.3220/1121125/320/10.361.321413 |0.901.3220/11516 |0.901.3220/1181715/220/10.500.792019 |0.300.7920/1212220/10.200.0020/1242320/120/10.000.00262520/10.000.0020/1272820/10.000.0020/1302920/120/10.000.00323120/10.000.0020/13334-/10.000.0020/13635-/1-/10.000.003837-/10.000.00-/13940-/10.000.00-/14241-/1-/10.000.004443-/10.000.00-/14546-/10.000.00-/14847-/1-/10.000.005049-/10.000.00-/15152-/10.000.00-/15453-/1-/10.000.00TOTAL CALCULATED AMPSCONN. KVATOTAL KVA(50%>10)(100%)(125%)(125%)RECEPTACLESOTHER MOTORSLARGEST MOTORLIGHTINGCALC. KVAHEATINGCONTINUOUSNONCOIN/DIVERSEKITCHEN EQUIPNONCONTINUOUS(100%)(125%)(100%)TOTAL CONNECTED LOAD (KVA)NOTES:METERED DEMAND(125%)COOLINGABCTOTAL CONNECTED LOAD (AMPS)ABC17.84(100%)0.003.966.924.951.000.003.966.923.960.80COMPUTER52.8219.032.000.000.200.000.002.000.000.200.000.00(N/A)(N/A)0.000.0049.520.000.00(N/A)6.946.414.4953.4637.6157.81FCU-351, FCU-352, FCU-353, FCU-354, FCU-355, FCU-500CU-04CU-05KE-7.2SPARESPARESPARESPARESPARESPARESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACEEH-51EH-52FIRE SMOKE DAMPERRECRECRECRECRECBUILDING SIGNAGELTGDOOR MAG HOLDSPARESPARESPARESPARESPARESPARESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACENEUTRAL:BUS AMPS:VOLTS:AIC:MAIN OCPD:LUGS:FED FROM:MOUNTING:LOCATION:CCTNO.NO.CCTCIRCUIT DESCRIPTIONCIRCUIT DESCRIPTIONPANEL:SEE ONE-LINE DIAGRAMENCLOSURE:KVA LOADBCCCTOCPDNOTESACCTOCPDNOTESL52SEE PLANSSURFACE208Y/120V 3P 4W20022,000MLOSTANDARD100%NEMA 121125/25.8011.58100/234 |5.7712.57 |65100/2100/25.805.8087 |5.415.41 |910100/25.805.72100/21211 | |5.415.591413100/25.805.80100/21516 |5.415.77 |1817-/1-/10.000.002019-/10.000.00-/12122-/10.000.00-/12423-/1-/10.000.002625-/10.000.00-/12728-/10.000.00-/13029-/1-/10.000.00TOTAL CALCULATED AMPSCONN. KVATOTAL KVA(50%>10)(100%)(125%)(125%)RECEPTACLESOTHER MOTORSLARGEST MOTORLIGHTINGCALC. KVAHEATINGCONTINUOUSNONCOIN/DIVERSEKITCHEN EQUIPNONCONTINUOUS(100%)(125%)(100%)TOTAL CONNECTED LOAD (KVA)NOTES:METERED DEMAND(125%)COOLINGABCTOTAL CONNECTED LOAD (AMPS)ABC103.42(100%)0.0012.740.000.006.480.0015.480.000.005.18COMPUTER283.05101.970.000.0082.760.000.000.000.0082.760.000.00(N/A)(N/A)0.000.00287.060.000.00(N/A)39.7941.0322.59346.23 188.21336.06PANEL E-502PANEL B-504PANEL A-508PANEL F-510SPACESPACESPACESPACESPACESPACESPACEPANEL F-512PANEL B-514PANEL B-516PANEL B-518SPACESPACESPACESPACESPACESPACESPACENEUTRAL:BUS AMPS:VOLTS:AIC:MAIN OCPD:LUGS:FED FROM:MOUNTING:LOCATION:CCTNO.NO.CCTCIRCUIT DESCRIPTIONCIRCUIT DESCRIPTIONPANEL:SEE ONE-LINE DIAGRAMENCLOSURE:KVA LOADBCCCTOCPDNOTESACCTOCPDNOTESL53SEE PLANSSURFACE208Y/120V 3P 4W20022,000MLOSTANDARD100%NEMA 121125/25.8011.58100/234 |5.4112.57 |65100/2100/25.805.8087 |5.415.76 |910100/25.805.72100/21211 | |5.415.591413100/25.805.72100/21516 |5.775.59 |1817-/1-/10.000.002019-/10.000.00-/12122-/10.000.00-/12423-/1-/10.000.002625-/10.000.00-/12728-/10.000.00-/13029-/1-/10.000.00TOTAL CALCULATED AMPSCONN. KVATOTAL KVA(50%>10)(100%)(125%)(125%)RECEPTACLESOTHER MOTORSLARGEST MOTORLIGHTINGCALC. KVAHEATINGCONTINUOUSNONCOIN/DIVERSEKITCHEN EQUIPNONCONTINUOUS(100%)(125%)(100%)TOTAL CONNECTED LOAD (KVA)NOTES:METERED DEMAND(125%)COOLINGABCTOTAL CONNECTED LOAD (AMPS)ABC103.50(100%)0.0012.740.000.006.370.0015.480.000.005.10COMPUTER283.23102.040.000.0082.930.000.000.000.0082.930.000.00(N/A)(N/A)0.000.00287.300.000.00(N/A)40.0640.8522.59344.75 188.21338.25PANEL E-501PANEL D-503PANEL A-505PANEL A-507SPACESPACESPACESPACESPACESPACESPACEPANEL B-519PANEL B-520PANEL B-521PANEL F-522SPACESPACESPACESPACESPACESPACESPACENEUTRAL:BUS AMPS:VOLTS:AIC:MAIN OCPD:LUGS:FED FROM:MOUNTING:LOCATION:CCTNO.NO.CCTCIRCUIT DESCRIPTIONCIRCUIT DESCRIPTIONPANEL:SEE ONE-LINE DIAGRAMENCLOSURE:KVA LOADBCCCTOCPDNOTESACCTOCPDNOTESL54SEE PLANSSURFACE208Y/120V 3P 4W20010,000MLOSTANDARD100%NEMA 121100/25.725.80100/234 |5.595.41 |65100/2100/25.725.8087 |5.595.41 |910100/25.805.72100/21211 | |5.775.591413100/25.805.72100/21516 |5.415.59 |1817-/1-/10.000.002019-/10.000.00-/12122-/10.000.00-/12423-/1-/10.000.002625-/10.000.00-/12728-/10.000.00-/13029-/1-/10.000.00TOTAL CALCULATED AMPSCONN. KVATOTAL KVA(50%>10)(100%)(125%)(125%)RECEPTACLESOTHER MOTORSLARGEST MOTORLIGHTINGCALC. KVAHEATINGCONTINUOUSNONCOIN/DIVERSEKITCHEN EQUIPNONCONTINUOUS(100%)(125%)(100%)TOTAL CONNECTED LOAD (KVA)NOTES:METERED DEMAND(125%)COOLINGABCTOTAL CONNECTED LOAD (AMPS)ABC90.40(100%)0.0012.740.000.005.920.0015.480.000.004.74COMPUTER246.6188.840.000.0070.180.000.000.000.0070.180.000.00(N/A)(N/A)0.000.00250.930.000.00(N/A)34.0333.5022.87280.54 190.51284.88PANEL B-523PANEL B-525PANEL A-527PANEL A-529SPACESPACESPACESPACESPACESPACESPACEPANEL A-531PANEL A-533PANEL F-535PANEL B-537SPACESPACESPACESPACESPACESPACESPACENEUTRAL:BUS AMPS:VOLTS:AIC:MAIN OCPD:LUGS:FED FROM:MOUNTING:LOCATION:CCTNO.NO.CCTCIRCUIT DESCRIPTIONCIRCUIT DESCRIPTIONPANEL:SEE ONE-LINE DIAGRAMENCLOSURE:KVA LOADBCCCTOCPDNOTESACCTOCPDNOTESL55SEE PLANSSURFACE208Y/120V 3P 4W20010,000MLOSTANDARD100%NEMA 121100/25.725.80100/234 |5.595.77 |65100/2100/25.805.8087 |5.775.41 |910100/25.805.72100/21211 | |5.415.591413100/20.005.80-/11516 |0.005.41-/11817-/1-/10.000.002019-/10.000.00-/12122-/10.000.00-/12423-/1-/10.000.002625-/10.000.00-/12728-/10.000.00-/13029-/1-/10.000.00TOTAL CALCULATED AMPSCONN. KVATOTAL KVA(50%>10)(100%)(125%)(125%)RECEPTACLESOTHER MOTORSLARGEST MOTORLIGHTINGCALC. KVAHEATINGCONTINUOUSNONCOIN/DIVERSEKITCHEN EQUIPNONCONTINUOUS(100%)(125%)(100%)TOTAL CONNECTED LOAD (KVA)NOTES:METERED DEMAND(125%)COOLINGABCTOTAL CONNECTED LOAD (AMPS)ABC79.36(100%)0.0011.840.000.005.340.0013.680.000.004.27COMPUTER218.1478.590.000.0061.410.000.000.000.0061.410.000.00(N/A)(N/A)0.000.00220.280.000.00(N/A)28.4928.2822.59235.98 188.21237.76PANEL F-524PANEL B-526PANEL A-528PANEL B-530SPACESPACESPACESPACESPACESPACESPACEPANEL A-534PANEL F-536PANEL B-538SPACESPACESPACESPACESPACESPACESPACESPACESPACE32 MERCHANT STREET, SUITE 208HONOLULU, HI 96813808-352-5299OWNER:HOMEWOOD SUITES by HILTON SPOKANE VALLEY, WA 13515 E. Carlisle Avenue Spokane Valley, WA 99216FSC PROJECT NO. 21012PERMITDOCUMENTSMay 31, 2024GL8 MirabeauPoint, LLCTMK:PID: 45101.0401 10909 E. Pierce LaneSpokane, WA 99206(509) 919-0901Revision ScheduleNumber Description Date5915 S REGAL STREETSUITE 201SPOKANE, WA 99223PH: 509.473.9218Kelly@kwrllc.comwww.kwrllc.com5/30/2024 1:27:53 PMSTATE OF WASHINGTONREGISTERED PROFESSIONAL ENG INEER48350 KELLY A N DREW WATERMAN05.31.24PANEL SCHEDULESE-610(SEE NOTE 'a')(SEE NOTE 'a')(SEE NOTE 'a')(SEE NOTE 'a') a.PROVIDE LOCKABLE CIRCUIT BREAKER.b. PROVIDE AFCI CIRCUIT BREAKER.c. PROVIDE COMBINATION AFCI / GFCI CIRCUIT BREAKER WITH 6mA TRIP.d. PROVIDE GFCI CIRCUIT BREAKER WITH 6mA TRIP.e. PANEL SCHEDULE SHOWN FOR BREAKER QUANTITIES AND PHASE / LOAD BALANCING. SEEALTERNATE CALCULATIONS FOR CALCULATED LOAD BASED UPON NEC ALLOWABLEDEMAND FACTORS.a,ccccbbbcccbbbcccbbbcccbbbcccbbbcccbbba,ca,ca. PROVIDE LOCKABLE CIRCUIT BREAKER.b. PROVIDE AFCI CIRCUIT BREAKER.c. PROVIDE COMBINATION AFCI / GFCI CIRCUIT BREAKER WITH 6mA TRIP.d. PROVIDE GFCI CIRCUIT BREAKER WITH 6mA TRIP.e. PANEL SCHEDULE SHOWN FOR BREAKER QUANTITIES AND PHASE / LOAD BALANCING. SEEALTERNATE CALCULATIONS FOR CALCULATED LOAD BASED UPON NEC ALLOWABLEDEMAND FACTORS.a. PROVIDE LOCKABLE CIRCUIT BREAKER.b. PROVIDE AFCI CIRCUIT BREAKER.c. PROVIDE COMBINATION AFCI / GFCI CIRCUIT BREAKER WITH 6mA TRIP.d. PROVIDE GFCI CIRCUIT BREAKER WITH 6mA TRIP.e. PANEL SCHEDULE SHOWN FOR BREAKER QUANTITIES AND PHASE / LOAD BALANCING. SEEALTERNATE CALCULATIONS FOR CALCULATED LOAD BASED UPON NEC ALLOWABLEDEMAND FACTORS.a. PROVIDE LOCKABLE CIRCUIT BREAKER.b. PROVIDE AFCI CIRCUIT BREAKER.c. PROVIDE COMBINATION AFCI / GFCI CIRCUIT BREAKER WITH 6mA TRIP.d. PROVIDE GFCI CIRCUIT BREAKER WITH 6mA TRIP.e. PANEL SCHEDULE SHOWN FOR BREAKER QUANTITIES AND PHASE / LOAD BALANCING. SEEALTERNATE CALCULATIONS FOR CALCULATED LOAD BASED UPON NEC ALLOWABLEDEMAND FACTORS.a. PROVIDE LOCKABLE CIRCUIT BREAKER.b. PROVIDE AFCI CIRCUIT BREAKER.c. PROVIDE COMBINATION AFCI / GFCI CIRCUIT BREAKER WITH 6mA TRIP.d. PROVIDE GFCI CIRCUIT BREAKER WITH 6mA TRIP.e. PANEL SCHEDULE SHOWN FOR BREAKER QUANTITIES AND PHASE / LOAD BALANCING. SEEALTERNATE CALCULATIONS FOR CALCULATED LOAD BASED UPON NEC ALLOWABLEDEMAND FACTORS.a. PROVIDE LOCKABLE CIRCUIT BREAKER.b. PROVIDE AFCI CIRCUIT BREAKER.c. PROVIDE COMBINATION AFCI / GFCI CIRCUIT BREAKER WITH 6mA TRIP.d. PROVIDE GFCI CIRCUIT BREAKER WITH 6mA TRIP.e. PANEL SCHEDULE SHOWN FOR BREAKER QUANTITIES AND PHASE / LOAD BALANCING. SEEALTERNATE CALCULATIONS FOR CALCULATED LOAD BASED UPON NEC ALLOWABLEDEMAND FACTORS.aaaaaaCIRCUIT DESCRIPTIONCIRCUIT DESCRIPTIONCCTOCPDNO.CCTNEUTRAL:BUS AMPS:VOLTS:AIC:MAIN OCPD:LUGS:FED FROM:MOUNTING:CCTNO.PANEL:SEE ONE-LINE DIAGRAMLOCATION:ENCLOSURE:NOTESKVA LOADABCCTOCPDNOTESHSTANDARDMLO22,000100208/120V 2P 3WFLUSHSEE PLANS100%NEMA 10.981.4720/120/221431.001.4720/1 |0.361.5020/120/265871.101.5020/1 |0.360.8620/120/110912111.080.1720/120/10.000.00-/1-/1141316150.000.00-/1-/10.000.00-/1-/1181720190.000.00-/1-/10.000.00-/1-/1222124230.000.00-/1-/1BALANCED PHASE AMPSCONN. KVATOTAL KVA(50%>10)(100%)(125%)(125%)RECEPTACLESOTHER MOTORSLARGEST MOTORLIGHTINGCALC. KVAHEATINGCONTINUOUSNONCOIN/DIVERSEKITCHEN EQUIPNONCONTINUOUS(100%)(125%)(100%)TOTAL CONN. LOAD (KVA)NOTES:ABTOTAL CONN. LOAD (AMPS)ABMETERED DEMAND11.85(100%)0.002.340.000.000.460.002.340.000.000.36COMPUTER57.4011.940.000.009.140.000.000.000.009.140.000.00(N/A)(N/A)0.000.0056.975.536.3148.2654.50PTAC-01COOK-2GDHOODSPACESPACESPACESPACESPACESPACEDW, REFMWLTG, VANITY MIRRORMOTORIZED SHADES, RECRECRECSPACESPACESPACESPACESPACESPACECIRCUIT DESCRIPTIONCIRCUIT DESCRIPTIONCCTOCPDNO.CCTNEUTRAL:BUS AMPS:VOLTS:AIC:MAIN OCPD:LUGS:FED FROM:MOUNTING:CCTNO.PANEL:SEE ONE-LINE DIAGRAMLOCATION:ENCLOSURE:NOTESKVA LOADABCCTOCPDNOTESFSTANDARDMLO22,000100208/120V 2P 3WFLUSHSEE PLANS100%NEMA 10.981.4720/120/221431.001.4720/1 |0.371.5020/120/265871.801.5020/1 |0.360.8620/120/110912110.000.18-/120/10.000.00-/1-/1141316150.000.00-/1-/10.000.00-/1-/1181720190.000.00-/1-/10.000.00-/1-/1222124230.000.00-/1-/1BALANCED PHASE AMPSCONN. KVATOTAL KVA(50%>10)(100%)(125%)(125%)RECEPTACLESOTHER MOTORSLARGEST MOTORLIGHTINGCALC. KVAHEATINGCONTINUOUSNONCOIN/DIVERSEKITCHEN EQUIPNONCONTINUOUS(100%)(125%)(100%)TOTAL CONN. LOAD (KVA)NOTES:ABTOTAL CONN. LOAD (AMPS)ABMETERED DEMAND11.49(100%)0.002.340.000.000.470.002.340.000.000.37COMPUTER55.6911.580.000.008.780.000.000.000.008.780.000.00(N/A)(N/A)0.000.0055.245.545.9548.3351.55PTAC-01COOK-2GDRECSPACESPACESPACESPACESPACESPACEDW, REFMW/HOODLTG, VANITY MIRRORRECRECSPACESPACESPACESPACESPACESPACESPACECIRCUIT DESCRIPTIONCIRCUIT DESCRIPTIONCCTOCPDNO.CCTNEUTRAL:BUS AMPS:VOLTS:AIC:MAIN OCPD:LUGS:FED FROM:MOUNTING:CCTNO.PANEL:SEE ONE-LINE DIAGRAMLOCATION:ENCLOSURE:NOTESKVA LOADABCCTOCPDNOTESDSTANDARDMLO22,000100208/120V 2P 3WFLUSHSEE PLANS100%NEMA 10.981.4720/120/221431.001.4720/1 |0.341.5020/120/265871.621.5020/1 |0.360.8620/120/110912110.000.17-/120/10.000.00-/1-/1141316150.000.00-/1-/10.000.00-/1-/1181720190.000.00-/1-/10.000.00-/1-/1222124230.000.00-/1-/1BALANCED PHASE AMPSCONN. KVATOTAL KVA(50%>10)(100%)(125%)(125%)RECEPTACLESOTHER MOTORSLARGEST MOTORLIGHTINGCALC. KVAHEATINGCONTINUOUSNONCOIN/DIVERSEKITCHEN EQUIPNONCONTINUOUS(100%)(125%)(100%)TOTAL CONN. LOAD (KVA)NOTES:ABTOTAL CONN. LOAD (AMPS)ABMETERED DEMAND11.26(100%)0.001.980.000.000.420.001.980.000.000.34COMPUTER54.5411.340.000.008.940.000.000.000.008.940.000.00(N/A)(N/A)0.000.0054.145.515.7548.0350.01PTAC-01COOK-2GDHOODSPACESPACESPACESPACESPACESPACEDW, REFMWLTG, VANITY MIRRORRECRECSPACESPACESPACESPACESPACESPACESPACECIRCUIT DESCRIPTIONCIRCUIT DESCRIPTIONCCTOCPDNO.CCTNEUTRAL:BUS AMPS:VOLTS:AIC:MAIN OCPD:LUGS:FED FROM:MOUNTING:CCTNO.PANEL:SEE ONE-LINE DIAGRAMLOCATION:ENCLOSURE:NOTESKVA LOADABCCTOCPDNOTESCSTANDARDMLO22,000100208/120V 2P 3WFLUSHSEE PLANS100%NEMA 10.981.4720/120/221431.001.4720/1 |0.311.5020/120/265871.621.5020/1 |0.360.8620/120/110912110.000.17-/120/10.000.00-/1-/1141316150.000.00-/1-/10.000.00-/1-/1181720190.000.00-/1-/10.000.00-/1-/1222124230.000.00-/1-/1BALANCED PHASE AMPSCONN. KVATOTAL KVA(50%>10)(100%)(125%)(125%)RECEPTACLESOTHER MOTORSLARGEST MOTORLIGHTINGCALC. KVAHEATINGCONTINUOUSNONCOIN/DIVERSEKITCHEN EQUIPNONCONTINUOUS(100%)(125%)(100%)TOTAL CONN. LOAD (KVA)NOTES:ABTOTAL CONN. LOAD (AMPS)ABMETERED DEMAND11.23(100%)0.001.980.000.000.380.001.980.000.000.31COMPUTER54.3611.310.000.008.940.000.000.000.008.940.000.00(N/A)(N/A)0.000.0053.995.485.7547.8050.01PTAC-01COOK-2GDHOODSPACESPACESPACESPACESPACESPACEDW, REFMWLTG, VANITY MIRRORRECRECSPACESPACESPACESPACESPACESPACESPACECIRCUIT DESCRIPTIONCIRCUIT DESCRIPTIONCCTOCPDNO.CCTNEUTRAL:BUS AMPS:VOLTS:AIC:MAIN OCPD:LUGS:FED FROM:MOUNTING:CCTNO.PANEL:SEE ONE-LINE DIAGRAMLOCATION:ENCLOSURE:NOTESKVA LOADABCCTOCPDNOTESBSTANDARDMLO22,000100208/120V 2P 3WFLUSHSEE PLANS100%NEMA 10.981.4720/120/221431.001.4720/1 |0.351.5020/120/265871.441.5020/1 |0.361.0420/120/110912110.000.00-/1-/10.000.00-/1-/1141316150.000.00-/1-/10.000.00-/1-/1181720190.000.00-/1-/10.000.00-/1-/1222124230.000.00-/1-/1BALANCED PHASE AMPSCONN. KVATOTAL KVA(50%>10)(100%)(125%)(125%)RECEPTACLESOTHER MOTORSLARGEST MOTORLIGHTINGCALC. KVAHEATINGCONTINUOUSNONCOIN/DIVERSEKITCHEN EQUIPNONCONTINUOUS(100%)(125%)(100%)TOTAL CONN. LOAD (KVA)NOTES:ABTOTAL CONN. LOAD (AMPS)ABMETERED DEMAND11.10(100%)0.001.980.000.000.430.001.980.000.000.35COMPUTER53.7911.190.000.008.780.000.000.000.008.780.000.00(N/A)(N/A)0.000.0053.375.705.4149.5447.24PTAC-01COOK-2GD, RECSPACESPACESPACESPACESPACESPACESPACEDW, REFMW/HOODLTG, VANITY MIRRORRECRECSPACESPACESPACESPACESPACESPACESPACECIRCUIT DESCRIPTIONCIRCUIT DESCRIPTIONCCTOCPDNO.CCTNEUTRAL:BUS AMPS:VOLTS:AIC:MAIN OCPD:LUGS:FED FROM:MOUNTING:CCTNO.PANEL:SEE ONE-LINE DIAGRAMLOCATION:ENCLOSURE:NOTESKVA LOADABCCTOCPDNOTESASTANDARDMLO22,000100208/120V 2P 3WFLUSHSEE PLANS100%NEMA 10.981.4720/120/221431.001.4720/1 |0.291.5020/120/265871.621.5020/1 |0.360.8620/120/110912110.000.00-/1-/10.000.00-/1-/1141316150.000.00-/1-/10.000.00-/1-/1181720190.000.00-/1-/10.000.00-/1-/1222124230.000.00-/1-/1BALANCED PHASE AMPSCONN. KVATOTAL KVA(50%>10)(100%)(125%)(125%)RECEPTACLESOTHER MOTORSLARGEST MOTORLIGHTINGCALC. KVAHEATINGCONTINUOUSNONCOIN/DIVERSEKITCHEN EQUIPNONCONTINUOUS(100%)(125%)(100%)TOTAL CONN. LOAD (KVA)NOTES:ABTOTAL CONN. LOAD (AMPS)ABMETERED DEMAND11.05(100%)0.001.980.000.000.370.001.980.000.000.29COMPUTER53.4711.120.000.008.780.000.000.000.008.780.000.00(N/A)(N/A)0.000.0053.125.465.5947.6848.67PTAC-01COOK-2GDSPACESPACESPACESPACESPACESPACESPACEDW, REFMW/HOODLTG, VANITY MIRRORRECRECSPACESPACESPACESPACESPACESPACESPACE32 MERCHANT STREET, SUITE 208HONOLULU, HI 96813808-352-5299OWNER:HOMEWOOD SUITES by HILTON SPOKANE VALLEY, WA 13515 E. Carlisle Avenue Spokane Valley, WA 99216FSC PROJECT NO. 21012PERMITDOCUMENTSMay 31, 2024GL8 MirabeauPoint, LLCTMK:PID: 45101.0401 10909 E. Pierce LaneSpokane, WA 99206(509) 919-0901Revision ScheduleNumber Description Date5915 S REGAL STREETSUITE 201SPOKANE, WA 99223PH: 509.473.9218Kelly@kwrllc.comwww.kwrllc.com5/30/2024 1:27:58 PMSTATE OF WASHINGTONREGISTERED PROFESSIONAL ENG INEER48350 KELLY A N DREW WATERMAN05.31.24PANEL SCHEDULESE-611UNIT TYPE A (TYPICAL)(SEE NOTE 'e')UNIT TYPE B (TYPICAL)(SEE NOTE 'e')UNIT TYPE C (TYPICAL)(SEE NOTE 'e')UNIT TYPE H (TYPICAL)(SEE NOTE 'e')UNIT TYPE F (TYPICAL)(SEE NOTE 'e')UNIT TYPE D (TYPICAL)(SEE NOTE 'e') acccbbbacccbbbcda,ccda. PROVIDE LOCKABLE CIRCUIT BREAKER.b. PROVIDE AFCI CIRCUIT BREAKER.c. PROVIDE COMBINATION AFCI / GFCI CIRCUIT BREAKER WITH 6mA TRIP.d. PROVIDE GFCI CIRCUIT BREAKER WITH 6mA TRIP.e. PANEL SCHEDULE SHOWN FOR BREAKER QUANTITIES AND PHASE / LOAD BALANCING. SEEALTERNATE CALCULATIONS FOR CALCULATED LOAD BASED UPON NEC ALLOWABLEDEMAND FACTORS.a. PROVIDE LOCKABLE CIRCUIT BREAKER.b. PROVIDE AFCI CIRCUIT BREAKER.c. PROVIDE COMBINATION AFCI / GFCI CIRCUIT BREAKER WITH 6mA TRIP.d. PROVIDE GFCI CIRCUIT BREAKER WITH 6mA TRIP.e. PANEL SCHEDULE SHOWN FOR BREAKER QUANTITIES AND PHASE / LOAD BALANCING. SEEALTERNATE CALCULATIONS FOR CALCULATED LOAD BASED UPON NEC ALLOWABLEDEMAND FACTORS.bCIRCUIT DESCRIPTIONCIRCUIT DESCRIPTIONCCTOCPDNO.CCTNEUTRAL:BUS AMPS:VOLTS:AIC:MAIN OCPD:LUGS:FED FROM:MOUNTING:CCTNO.PANEL:SEE ONE-LINE DIAGRAMLOCATION:ENCLOSURE:NOTESKVA LOADABCCTOCPDNOTESGSTANDARDMLO22,000125208/120V 2P 3WFLUSHSEE PLANS100%NEMA 10.981.4720/120/221431.001.4720/1 |0.433.1220/130/265871.123.1220/1 |0.360.8620/120/110912112.500.1730/220/12.501.47 |20/2141316151.201.4720/1 |0.001.44-/120/1181720190.000.00-/1-/10.000.00-/1-/1222124230.000.00-/1-/1BALANCED PHASE AMPSCONN. KVATOTAL KVA(50%>10)(100%)(125%)(125%)RECEPTACLESOTHER MOTORSLARGEST MOTORLIGHTINGCALC. KVAHEATINGCONTINUOUSNONCOIN/DIVERSEKITCHEN EQUIPNONCONTINUOUS(100%)(125%)(100%)TOTAL CONN. LOAD (KVA)NOTES:ABTOTAL CONN. LOAD (AMPS)ABMETERED DEMAND24.67(100%)0.002.520.000.000.540.002.520.000.000.43COMPUTER119.1224.780.000.0021.720.000.000.000.0021.720.000.00(N/A)(N/A)0.000.00118.6012.6312.04112.93 108.39PTAC-01COOK-4GDHOODPTAC-01RECSPACESPACESPACEDW, REFMWLTG, VANITY MIRRORMOTORIZED SHADES, RECRECDRYWASHSPACESPACESPACESPACECIRCUIT DESCRIPTIONCIRCUIT DESCRIPTIONCCTOCPDNO.CCTNEUTRAL:BUS AMPS:VOLTS:AIC:MAIN OCPD:LUGS:FED FROM:MOUNTING:CCTNO.PANEL:SEE ONE-LINE DIAGRAMLOCATION:ENCLOSURE:NOTESKVA LOADABCCTOCPDNOTESESTANDARDMLO22,000125208/120V 2P 3WFLUSHSEE PLANS100%NEMA 10.981.4720/120/221431.001.4720/1 |0.433.1220/130/265870.743.1220/1 |0.360.8620/120/110912112.501.4730/220/22.501.47 | |141316151.201.2620/120/10.000.00-/1-/1181720190.000.00-/1-/10.000.00-/1-/1222124230.000.00-/1-/1BALANCED PHASE AMPSCONN. KVATOTAL KVA(50%>10)(100%)(125%)(125%)RECEPTACLESOTHER MOTORSLARGEST MOTORLIGHTINGCALC. KVAHEATINGCONTINUOUSNONCOIN/DIVERSEKITCHEN EQUIPNONCONTINUOUS(100%)(125%)(100%)TOTAL CONN. LOAD (KVA)NOTES:ABTOTAL CONN. LOAD (AMPS)ABMETERED DEMAND23.94(100%)0.002.160.000.000.540.002.160.000.000.43COMPUTER115.6224.050.000.0021.350.000.000.000.0021.350.000.00(N/A)(N/A)0.000.00115.1011.1912.75101.85 113.90PTAC-01COOK-4GDPTAC-01RECSPACESPACESPACESPACEDW, REFMW/HOODLTG, VANITY MIRRORMOTORIZED SHADES, RECRECDRYWASHSPACESPACESPACESPACE32 MERCHANT STREET, SUITE 208HONOLULU, HI 96813808-352-5299OWNER:HOMEWOOD SUITES by HILTON SPOKANE VALLEY, WA 13515 E. Carlisle Avenue Spokane Valley, WA 99216FSC PROJECT NO. 21012PERMITDOCUMENTSMay 31, 2024GL8 MirabeauPoint, LLCTMK:PID: 45101.0401 10909 E. Pierce LaneSpokane, WA 99206(509) 919-0901Revision ScheduleNumber Description Date5915 S REGAL STREETSUITE 201SPOKANE, WA 99223PH: 509.473.9218Kelly@kwrllc.comwww.kwrllc.com5/30/2024 1:28:03 PMSTATE OF WASHINGTONREGISTERED PROFESSIONAL ENG INEER48350 KELLY A N DREW WATERMAN05.31.24PANEL SCHEDULESE-612UNIT TYPE E (TYPICAL)UNIT TYPE G (TYPICAL)(SEE NOTE 'e')(SEE NOTE 'e') CEILING SPACEFLOORCEILING SPACENYLON THROAT CONNECTORAND PLASTIC BUSHING (TYP).PULL CORDSTUB RACEWAY ABOVE ABOVEACCESSIBLE CEILING1" CONDUIT2-1/8" DEEP, 4" SQUARE OUTLET BOXWHEN DEVICE IS SHOWN ONMEZZANINE LEVEL, STUB RACEWAYINTO ACCESSIBLE CEILING SPACEBELOW, OR INTO NEAREST IDF ROOMPULL CORDEXTENSION 'MUD' RING, SIZEDTO ACCOMMODATE DEVICESSHOWN, WITH DEPTH ASREQUIRED FOR FLUSHINSTALLATION. MUD RING TOFINISH TO WALL SURFACESUCH THAT DEVICES CAN BEMOUNTED WITHOUT SHIMS.COORDINATE DEPTH OF ALLMUD RINGS WITH THE WALLFINISHES FOR WHICH THEYARE INSTALLED.STANDARD RADIUS CONDUITSWEEPGENERAL NOTES:1. ATTACH FIXTURE TO SUSPENDEDCEILING SYSTEM WITH 4 EARTHQUAKECLIPS.2. MC CABLE IS ALLOWED FORMANUFACTURED FIXTURE WHIPS.3. DETAIL IS TYPICAL FOR ALL RECESSEDFIXTURES IN SUSPENDED T-BARCEILING SYSTEMSHILTI CC27 CLIP OREQUAL (TYPICAL)STRUCTURENO. 10 SAFETY WIRES TIED TO SAFETY WIRESUPPORT HOLES, FASTEN TO BUILDINGSTRUCTURE, MINIMUM (4) WIRES PER LIGHTFIXTURE PLACED AT CORNERS. INSTALL SUCHTHAT FIXTURE DROPS NOT MORE THAN 6INCHES IN THE EVENT OF CEILING GRID FAILURE3-TWIST MINIMUMLUMINAIRE MANUFACTURER'SEARTHQUATE CLIP, (4) PERFIXTURE AT CORNERS, ATTACHEDWITH SHEET METAL SCREWFIXTURE WHIP FROMJUNCTION BOX(6-FOOT LONG MAX)LUMINAIRE PER SCHEDULET-BAR GRID (BY OTHERS)ACOUSTICAL CEILING TILE(TYPICAL)LUMINAIRE PERSCHEDULET-BAR CEILING GRID(BY OTHERS)SEAL WITH FIRE BARRIER (WHEREREQUIRED TO MAINTAIN FIRE RATINGOF FIRE-RATED PARTITIONS) AFTERCABLE INSTALLATION. FOR EMPTYCONDUITS PROVIDE REMOVABLE FIREBARRIER IN EACH END OF SLEEVE.DETAIL NOTES:1. THIS DETAIL SHOWS A WIRING / CABLING CHASE THROUGH A PARTITION ONLY. SOFFIT CHASESARE SIMILAR IN SUPPORT AND END FITTINGS. EXTEND BEYOND SOFFIT AREAS OR PASTDUCTWORK INTO ACCESSIBLE CEILING SPACES OR MEZZANINE SPACES.PLASTIC INSULATED PRESS-ONBUSHINGS ON EACHPULL CORDEMT CONDUIT SLEEVE: LENGTH ASREQUIRED TO EXTEND BEYONDNON-ACCESSIBLE CEILING OR DUCTWORKCONDUIT STRAP / SUPPORT TO WALL STUDPROVIDE CAULKING AROUND SLEEVE ATRATED ASSEMBLIES. PROVIDE FIRE CAULKSUSPENDED CEILINGNEUTRAL BUS#4 MAIN BONDING JUMPER(NEC 250.28)#6 BARE COPPER TO GROUND RODS(NEC 250.52.A.5)#2 BARE COPPER TO CONCRETEENCASED ELECTRODE(NEC 250.52.A.3)3/4" COPPER-CLAD GROUNDRODS (4 MINIMUM) AT CORNERPOINTS OF PAD, CONCEAL AFTERINSPECTIONGRADE#4 COPPER EQUIPMENT BONDINGJUMPER (NEC 250.92)EQUIPMENT GROUNDING BUS20'-0" MINNEW GENERATORNEWGENERATOR#4 BARE COPPER GROUNDRING (TYP.)3/4" COPPER-CLAD GROUNDRODS (4 MINIMUM) ATCORNER POINTS OF PAD,CONCEAL AFTER INSPECTION#4 BARE COPPER BONDEDTO EQUIPMENT (TYP.)PLAN VIEW GENERATOR GROUNDING ELECTRODE SYSTEMBOND TO BUILDING FOUNDATION STEELAND REBAR SUPPORT IN CMU WALLMINIMUM OF 20'-0" OF CONTINUOUSBARE COPPER CONDUCTORENCASED IN NOT LESS THAN 2" OFCONCRETE COVERNEUTRAL BUS#500 KCMIL MAINBONDING JUMPER(NEC 250.28)#2 BARE COPPER TO INTERSYSTEMBONDING TERMINATION(NEC 250.94)#4 BARE COPPER#3/0 BARE COPPER TOCONCRETE ENCASEDELECTRODE3/4" COPPER-CLAD GROUNDRODS (2 MINIMUM), CONCEALAFTER INSPECTIONGRADE#500 KCMIL COPPEREQUIPMENT BONDING JUMPER(NEC 250.92)EQUIPMENT GROUNDING BUS#3/0 BARE COPPER GROUNDING ELECTRODECONDUCTOR TO NEAREST ACCESSIBLE POINTOF INCOMING METAL WATER SERVICE PIPING,PROVIDE CLAMPS AS NECESSARY(NEC 250.104.A.1)#3/0 BARE COPPER GROUNDING ELECTRODECONDUCTOR TO INTERIOR METAL GASPIPING, PROVIDE CLAMPS AS NECESSARY(NEC 250.104.B)WATERMETERUNDERGROUND WATER PIPE20'-0" MINMAIN SERVICE#3/0 BARE COPPER GROUNDING ELECTRODECONDUCTOR TO EFFECTIVELY GROUNDEDMETAL FRAME OF BUILDING(NEC 250.52.A.2)METAL IN-GROUND SUPPORT STRUCTUREMINIMUM 20'-0" OF CONTINUOUS BARE COPPERCONDUCTOR ENCASED IN NOT LESS THAN 2" OFCONCRETE COVERNEUTRAL BUS#6 BARE COPPER#6 AWG BARE COPPERTO CONCRETEENCASED ELECTRODE3/4" COPPER-CLAD GROUNDRODS (2 MINIMUM), CONCEALAFTER INSPECTIONGRADE#6 AWG COPPER EQUIPMENTBONDING JUMPER(NEC 250.92)EQUIPMENT GROUNDING BUS20'-0" MINSITE STORAGEBUILDING#6 AWG BARE COPPER GROUNDINGELECTRODE CONDUCTOR TO EFFECTIVELYGROUNDED METAL FRAME OF BUILDING(NEC 250.52.A.2)METAL IN-GROUND SUPPORT STRUCTUREMINIMUM 20'-0" OF CONTINUOUS BARE COPPERCONDUCTOR ENCASED IN NOT LESS THAN 2" OFCONCRETE COVERDO NOT BOND GROUNDAND NEUTRAL BUSESEQUIPMENT GROUNDINGCONDUCTOR WITH FEEDERSIZED PER ONE-LINE DIAGRAM.32 MERCHANT STREET, SUITE 208HONOLULU, HI 96813808-352-5299NOTE: CONTRACTOR SHALL CHECK ANDVERIFY ALL DIMENSIONS AT JOB BEFOREPROCEEDING WITH WORK.OWNER:THIS WORK WAS PREPARED BY ME OR UNDERMY SUPERVISION AND CONSTRUCTION OF THISPROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTON SPOKANE VALLEY, WA 13515 E. Carlisle Avenue Spokane Valley, WA 99216FSC PROJECT NO. 21012PERMITDOCUMENTSMarch 31, 2024GL8 MirabeauPoint, LLCTMK:PID: 45101.0401 10909 E. Pierce LaneSpokane, WA 99206(509) 919-0901Revision ScheduleNumber Description Date5915 S REGAL STREETSUITE 201SPOKANE, WA 99223PH: 509.473.9218Kelly@kwrllc.comwww.kwrllc.comKELLY A N DREW WATERMANSTATE OF WASHINGTONREGISTERED PROFESSIONAL ENG INEER48350 PRELIMINARY5/28/2024 5:04:06 PMELECTRICAL DETAILSE-701SCALE:1LUMINAIRE SEISMIC MOUNTING DETAILNTSSCALE:3TYPICAL DATA ROUGH-IN DETAILNTSSCALE:2CONDUIT SLEEVE DETAILNTSSCALE:5GENERATOR GROUNDING DETAILNTSSCALE:4MAIN SERVICE GROUNDING DETAILNTS 4" SQUARE BOX & COVER12" FROM CEILING (DIV 26)CFCI CONDUIT EMBEDDED INWALL 1/2" CONDUIT MIN. STUBINTO DOOR FRAME OR STOREFRONT STRUCTURE (DIV 26)CFCI RACEWAY & OFOICABLE FOR DOOR LOCKOFOI CABLE FOR DOORCONTACT SWITCH (DIV 08)OFOI CABLE FOR REQUESTTO EXIT DEVICE MOTIONDETECTOR VERIFY WITHOWNER SECURITY PROVIDEROFOI CABLE FOR CARD READER(TYPICAL)SECURE SIDE CARD READER W/COVER PLATE.46"ACCESS CONTROL READERSMOUNT @ 48" AFF* SEE DOOR HARDWARESCHEDULE FOR OTHERELECTRIC OR MAGNETICLOCKING DEVICESPROVIDED BY DIV 08.ACCESSIBLE CEILINGMAGNETIC DOOR CONTACT SWITCH (DIV08) EMBEDDED IN DOOR AND DOOR JAMCABLE(S) TO ACCESS DOORCONTROLLER AND SECURITYPANEL LOCATED IN MDF / ITROOM VIA RACEWAYELECTRIC STRIKEEMBEDDED IN DOOR JAMDOOR FRAMEFINISH FLOORFLOOR SLABELECTRIC STRIKE*DOOR FRAME3/4" CONDUIT (MIN.)TO CONTROL PANELSX1H1 X2 H2 X3 H3 X0NEUTRAL BUSSUPPLY SIDE BONDINGJUMPER PER NEC 250.66GROUND BUSDISTRIBUTION ORBRANCH PANELDRY-TYPE TRANSFORMERSEPARATELY DERIVED SYSTEMSEISMIC SPRING MOUNTWITH 1" DEFLECTION(TYPICAL OF 4)MAIN CIRCUITBREAKERFLEXIBLEMETALLICCONDUITGROUNDING ELECTRODE SYSTEM,BOND TO BUILDING STEEL(TYPICAL FOR SEPARATELY DERIVED SYSTEMS)EQUIPMENTGROUNDINGCONDUCTORHOUSEKEEPING PAD(REFER TO STRUCTURAL)480V FEEDER FROMUPSTREAM DISTRIBUTIONEQUIPMENTHOUSEKEEPING PAD(REFER TO STRUCTURAL)FINISHED FLOORSECONDARY CONDUCTORS: MUSTNOT EXCEED 25' PRIOR TOTERMINATING INTO OVERCURRENTDEVICE PER NEC 240.21(C)(6).PROVIDE DEDICATED 20A, 120V CIRCUIT BREAKER WITH RED, LOCKABLE HANDLE CAPABLE OF BEING LOCKED IN THE "ON" POSITION. SEE POWER AND FIRE ALARM SHEETS FOR PROPOSED NUMBER AND LOCATION OF ALL FIRE ALARM EQUIPMENT, DEVICES, ETC. EXACTQUANTITY AND LOCATIONS TO BE DETERMINED BY THE FIRE ALARM INSTALLER.SIZE CONDUIT AND WIRES IN ACCORDANCE WITH FIRE ALARM SYSTEM MANUFACTURER RECOMMENDATIONS AND SPECIFICATIONS.EXACT QUANTITY OF FLOW AND TAMPER SWITCHES TO BE DETERMINED BY SPRINKLER SUPPLIER. FIELD COORDINATE WITHSPRINKLER INSTALLER PRIOR TO BIDDING FOR QUANTITY AND LOCATION OF FLOW AND TAMPER SWITCHES.EXTERIOR DEVICES TO BE ON SEPARATE CIRCUIT.VISUAL NOTIFICATION AND SPEAKER / STROBE COMBINATION DEVICES. VERIFY CONDUIT AND CABLE TYPE/SIZE WITH SYSTEMINSTALLER.PROVIDE BATTERY BOX(ES) AS REQUIRED TO ENSURE A MINIMUM OF 24 HOURS OF OPERATION UPON LOSS OF NORMAL POWER.PROVIDE SBUS COMMUNICATIONS SINGLE-MODE FIBER OPTIC MODULES TO NETWORK REMOTE FIRE ALARM PANELS TO MASTERPANEL. PROVIDE SINGLE-MODE FIBER BETWEEN PANELS PER MANUFACTURER'S INSTRUCTIONS. NEW ADDRESSABLE FIRE ALARMCONTROL PANELSLC #1SHSLC #2SHSUPERVISORY INPUTTSFS4NAC CIRCUITSPRINKLERALARM BELLDIGITAL ALARM COMMUNICATORTRANSMITTER (DACT)CONNECT TO TELEPHONEBACKBOARD. PROVIDE 4-PAIRTELEPHONE CABLE.BATTERYPOWERSUPPLY120VAC POWER CONNECTION,SEE PLANS FOR CIRCUITING.1WPWPWPBNAC CIRCUITDETAIL FLAG NOTES:1234567J723333TO NEXT ADDRESSABLEINITIATING DEVICETO NEXT ADDRESSABLEINITIATING DEVICETO NEXT STROBEOR EOLRTO NEXT STROBEOR EOLRNETWORK INTERFACE CARD5BACKUP CELLULAR DIALERRZVOLTAGE MONITORING FOR FIREALARM SYSTEM INTERFACERELAYS FOR FLOOR RECALL ANDFIREMAN'S SERVICE.COORDINATE QUANTITY WITHELEVATOR INSTALLERDETECTOR OUTPUT SIGNALS TOELEVATOR CONTROL MODULEPROVISIONS FOR FUTURE INTERFACEWITH TYPE 1 KITCHEN HOOD8 NEW ADDRESSABLE FIRE ALARMSLAVE PANELSLC #1SHSLC #2SHBATTERYPOWERSUPPLY7233TO NEXT ADDRESSABLEINITIATING DEVICETO NEXT ADDRESSABLEINITIATING DEVICE8120VAC POWER CONNECTION,SEE PLANS FOR CIRCUITING.1J8NAC CIRCUITWPWPWPNAC CIRCUIT33TO NEXT STROBEOR EOLRTO NEXT STROBEOR EOLR5TO BUILDING LOCAL AREA NETWORK32 MERCHANT STREET, SUITE 208HONOLULU, HI 96813808-352-5299OWNER:HOMEWOOD SUITES by HILTON SPOKANE VALLEY, WA 13515 E. Carlisle Avenue Spokane Valley, WA 99216FSC PROJECT NO. 21012PERMITDOCUMENTSMay 31, 2024GL8 MirabeauPoint, LLCTMK:PID: 45101.0401 10909 E. Pierce LaneSpokane, WA 99206(509) 919-0901Revision ScheduleNumber Description Date5915 S REGAL STREETSUITE 201SPOKANE, WA 99223PH: 509.473.9218Kelly@kwrllc.comwww.kwrllc.com5/30/2024 12:48:48 PMSTATE OF WASHINGTONREGISTERED PROFESSIONAL ENG INEER48350 KELLY A N DREW WATERMAN05.31.24ELECTRICAL DETAILSE-702SCALE:1ACCESS DOOR ROUGH-IN DETAILNTSSCALE:2DRY-TYPE TRANSFORMER DETAILNTSSCALE:3FIRE ALARM RISER DIAGRAMNTS