BUILDING PLANS - BLD-2024-0696737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216TITLE SHEET & INDEX
G-001
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
HOMEWOOD SUITES by HILTON
SPOKANE VALLEY, WA
13515 E. Carlisile Avenue
Spokane Valley, WA 99216
PID: 45101.0401
BID/PERMIT SET
MAY 31, 2024
GENERAL
G-001 TITLE SHEET & INDEX
G-002 PROJECT INFORMATION
G-003 BUILDING DEVELOPMENT INFORMATION
STRUCTURAL
S-001 GENERAL STRUCTURAL NOTES
S-002 ABBREVIATIONS & LEGENDS
S-003 SPECIAL INSPECTIONS & TESTING
S-004 TYPICAL DETAILS - CONCRETE
S-005 TYPICAL DETAILS - WOOD
S-006 TYPICAL DETAILS - WOOD
S-007 TYPICAL DETAILS - STEEL
S-008 TYPICAL DETAILS - STEEL
S-101 OVERALL FLOOR/FOUNDATION PLAN & 1ST FLOOR WALLS
S-102 OVERALL FLOOR 2 FRAMING PLAN & 2ND FLOOR WALLS
S-103 OVERALL FLOOR 3 FRAMING PLAN & 3RD FLOOR WALLS
S-104 OVERALL FLOOR 4 FRAMING PLAN & 4TH FLOOR WALLS
S-105 OVERALL FLOOR 5 FRAMING PLAN & 5TH FLOOR WALLS
S-106 OVERALL ROOF FRAMING PLAN & PARAPET WALLS
S-121 FLOOR FOUNDATION PLAN - WEST WING
S-122 FLOOR FOUNDATION PLAN - EAST WING
S-123 PORTE COCHERE FOUNDATION & ROOF FRAMING PLANS
S-124 FLOOR 2 FRAMING PLAN - WEST WING
S-125 FLOOR 2 FRAMING PLAN - EAST WING
S-126 FLOORS 3-5 FRAMING PLANS - WEST WING
S-127 FLOORS 3-5 FRAMING PLANS - EAST WING
S-128 ROOF FRAMING PLAN - WEST WING
S-129 ROOF FRAMING PLAN - EAST WING
S-130 CANOPY FRAMING PLAN & STEEL FRAME ELEVATIONS
S-301 FOUNDATION DETAILS
S-401 FLOOR FRAMING DETAILS
S-402 FLOOR FRAMING DETAILS
S-501 ROOF FRAMING DETAILS
S-502 ROOF FRAMING DETAILS
S-601 ENLARGED BALCONY PLANS & DETAILS
ARCHITECTURAL
A-001 CODE PLANS
A-002 BUILDING ENVELOPE & ACCESIBILITY PLANS
A-010 OVERALL SITE PLAN
A-101 OVERALL 1ST FLOOR PLAN
A-102 OVERALL 2ND FLOOR PLAN
A-103 OVERALL 3RD FLOOR PLAN
A-104 OVERALL 4TH FLOOR PLAN
A-105 OVERALL 5TH FLOOR PLAN
A-106 ROOF PLAN
A-107 LOWER ROOF PLAN
A-111 OVERALL 1ST FLOOR REFLECTED CEILING PLAN - WEST WING
A-112 OVERALL 1ST FLOOR REFLECTED CEILING PLAN - EAST WING
A-113 OVERALL TYP. 2ND TO 5TH FLOOR REFLECTED CEILING PLAN- WEST WING
A-114 OVERALL TYP. 2ND TO 5TH FLOOR REFLECTED CEILING PLAN- EAST WING
A-121 1ST FLOOR CONTRUCTION PLAN - WEST WING
A-122 1ST FLOOR CONTRUCTION PLAN - EAST WING
A-123 TYPICAL 2ND-5TH FLOOR CONTRUCTION PLAN - WEST WING
A-124 TYPICAL 2ND-5TH FLOOR CONTRUCTION PLAN - EAST WING
A-131 1ST FLOOR FINISH PLAN - WEST WING
A-132 1ST FLOOR FINISH PLAN - EAST WING
A-133 TYPICAL 2ND-5TH FLOOR FINISH PLAN - WEST WING
A-134 TYPICAL 2ND-5TH FLOOR FINISH PLAN - EAST WING
A-201 BUILDING ELEVATIONS
A-202 BUILDING ELEVATIONS
A-301 BUILDING SECTIONS
A-302 BUILDING SECTIONS
A-401 ENLARGED EV PARKING & PET RELIEF AREA
A-402 ENLARGED STORAGE SHED & TRASH ENCLOSURE
A-403 ENLARGED COURTYARD PLANS
A-404 ENLARGED OUTDOOR KITCHEN PLANS
A-405 ENLARGED OUTDOOR KITCHEN ELEVATIONS, SECTIONS &DETAILS
A-406 ENLARGED OUTDOOR KITCHEN DETAILS
A-407 ENLARGED PORTE COCHERE PLAN
A-411 UNIT PLANS - EFFICIENCY STUDIO
A-411A UNIT PLANS - EFFICIENCY STUDIO - ELEC, DATA & FLOORFINISH PLAN
A-411B UNIT INT. ELEVATIONS - EFFICIENCY STUDIO
A-412 UNIT PLAN - EFFICIENCY STUDIO ADA MOBILITY
A-412A UNIT PLAN - EFFICIENCY STUDIO ADA MOBILITY - ELEC, DATA& FLOOR FINISH PLAN
A-412B UNIT INT. ELEVATIONS - EFFICIENCY STUDIO ADA MOBILITY
A-413 UNIT PLAN - EFFICIENCY STUDIO ENLARGED
A-413A UNIT PLAN - EFFICIENCY STUDIO ENLARGED - ELEC, DATA &FLOOR FINISH PLAN
A-413B UNIT INT. ELEVATIONS - EFFICIENCY STUDIO ENLARGED
A-414 UNIT PLAN - KING STUDIO
A-414A UNIT PLAN - KING STUDIO - ELEC, DATA & FLOOR FINISH PLAN
A-414B UNIT INT. ELEVATIONS - KING STUDIO
A-415 UNIT PLAN - KING STUDIO ADA MOBILITY
A-415A UNIT PLAN - KING STUDIO ADA MOBILITY - ELEC, DATA &FLOOR FINISH PLAN
A-415B UNIT INT. ELEVATIONS - KING STUDIO ADA MOBILITY
A-416 UNIT PLAN - KING STUDIO ENLARGED
A-416A UNIT PLAN - KING STUDIO ENLARGED - ELEC, DATA & FLOORFINISH PLAN
A-416B UNIT INT. ELEVATIONS - KING STUDIO ENLARGED
A-417 UNIT PLAN - KING 1-BEDROOM
A-417A UNIT PLAN - KING 1-BEDROOM - ELEC, DATA & FLOOR FINISHPLAN
A-417B UNIT INT. ELEVATIONS - KING 1-BEDROOM
A-418 UNIT PLAN - KING 1-BEDROOM ADA MOBILITY
A-418A UNIT PLAN - KING 1-BEDROOM ADA - ELEC, DATA & FLOORFINISH PLAN
A-418B UNIT INT. ELEVATIONS - KING 1-BR ADA MOBILITY
A-419 UNIT PLAN - KING 1-BEDROOM ENLARGED
A-419A UNIT PLAN - KING 1-BEDROOM ENLARGED - ELEC, DATA &FLOOR FINISH PLAN
A-419B UNIT INT. ELEVATIONS - KING 1-BEDROOM ENLARGED
A-420 UNIT PLAN - DOUBLE QUEEN STUDIO
A-420A UNIT PLAN - DOUBLE QUEEN STUDIO - ELEC, DATA & FLOORFINISH PLAN
A-420B UNIT INT. ELEVATION - DOUBLE QUEEN STUDIO
A-421 UNIT PLAN - DOUBLE QUEEN STUDIO ADA MOBILITY
A-421A UNIT PLAN - DOUBLE QUEEN STUDIO ADA- ELEC, DATA &FLOOR FINISH PLAN
A-421B UNIT INT. ELEVATION - DOUBLE QUEEN STUDIO ADA MOBILITY
A-422 UNIT PLAN - DOUBLE QUEEN STUDIO ENLARGED
A-422A UNIT PLAN - DOUBLE QUEEN STUDIO ENLARGED - ELEC, DATA& FLOOR FINISH PLAN
A-422B UNIT INT. ELEVATION - DOUBLE QUEEN STUDIO ENLARGED
A-423 UNIT BATH - EFFICIENCY BATH PLANS AND INTERIORELEVATIONS
A-424 UNIT BATH -ACCESSIBLE BATH PLANS AND INTERIORELEVATIONS
A-425 UNIT BATH - STUDIO BATH PLANS AND INTERIOR ELEVATIONS
A-426 RESTROOM ACCESSORY AND MOUNTING DETAILS
PROJECT TEAMSHEET INDEX
OWNER
GL8 MIRABEAU POINT, LLC10909 EAST PIERCE LANESPOKANE, WA 99206(509) 919-0901
ARCHITECT
FSC ARCHITECTS737 BISHOP STREETSUITE 1860HONOLULU, HI 96813(808) 352-5299
CONTRACTOR
BAKER CONSTRUCTION2711 EAST SPRAGUE AVENUESPOKANE, WA 99202(509) 535-3668
CIVIL ENGINEER
SIMPSON ENGINEERS909 NORTH ARGONNE ROADSPOKANE VALLEY, WA 99212(509) 926-1322
LANDSCAPE ARCHITECT
SPVV LANDSCAPE ARCHITECTS1908 WEST NORTHWEST BOULEVARDSUITE ASPOKANE, WA 99205(509) 325-0511
STRUCTURAL ENGINEER
LSB CONSULTING ENGINEERS523 EAST THIRD AVENUESPOKANE, WA 99202(509) 323-9292
MECHANICAL/PLUMBING ENGINEER
COFFMAN ENGINEERS, INC.10 NORTH POST STREETSUITE 500SPOKANE, WA 99223(509) 328-6169
POOL DESIGNER
SELECT DESIGN BUILD CONSTRUCTION4810 POINT FOSDICK DRIVESUITE 117GIG HARBOR, WA 98335(253) 777-6109
FIRE SPRINKLER DESIGNER
INLAND EMPIRE FIRE PROTECTION3832 E. BOONE AVESPOKANE, WA, 99202(509) 534-1097
KITCHEN DESIGNER
SPOKANE RESTAURANT EQUIPMENT1750 EAST TRENT AVENUESPOKANE, WA 99202(509) 868-2713
ELEVATOR DESIGNER
OTIS ELEVATORS510 EAST NORTH FOOTHILLS DRIVESPOKANE, WA 99207(509) 951-2280
LOW VOLTAGE DESIGNER
FIREPOWER, INC.10220 NORTH NEVADA STREETSUITE 80SPOKANE, WA 99218(888) 706-3473
A-431 ENLARGED PLAN - LOBBY, MEETING ROOM, RESTROOMS &STORAGE
A-432 INTERIOR ELEVATIONS - LOBBY
A-432A INTERIOR ELEVATIONS - LOBBY, VESTIBULE
A-433 INTERIOR ELEVATIONS - MTG. ROOM & STO, ELEVATORLOBBY, GUEST STO.
A-434 ENLARGED PLAN & INTERIOR ELEVATIONS - OFFICES ANDFOOD PREP
A-434A INTERIOR ELEVATIONS - FOOD PREP
A-435 ENLARGED PLAN AND INTERIOR ELEVATIONS - EMPLOYEE,FITNESS & LAUNDRY LOUNGE
A-436 INTERIOR ELEVATIONS - EMPLOYEE RESTROOM
A-437 INTERIOR ELEVATIONS - PUBLIC RESTROOM PLAN ANDINTERIOR ELEVATIONS
A-438 INTERIOR ELEVATIONS - PUBLIC RESTROOM RCP ANDINTERIOR ELEVATIONS
A-442 ENLARGED BOH PLAN & INTERIOR ELEVATIONS
A-443 BOH INTERIOR ELEVATIONS
A-444 ENLARGED PLAN - POOL, SPLASH PAD, RESTROOM & MEPAND ELECTRICAL
A-445 ENLARGED FFE PLAN -POOL, SPLASH PAD, RESTROOM & MEPAND ELECTRICAL
A-446 INTERIOR ELEVATIONS - POOL & SPLASH PAD
A-447 ENLARGED POOL RESTROOM DRAWINGS
A-448 ENLARGED PLAN & INTERIOR ELEVATIONS - OFFICE /STORAGE / PBX ROOM
A-450 ENLARGED PLAN & INTERIOR ELEVATIONS - GUESTCORRIDOR EAST WING
A-451 ENLARGED PLAN & INTERIOR ELEVATIONS - GUESTCORRIDOR EAST WING
A-452 ENLARGED PLAN & INTERIOR ELEVATIONS - GUESTCORRIDOR WEST WING
A-453 ENLARGED PLAN & INTERIOR ELEVATIONS - TYP. LVL. GUESTCORRIDOR WEST WING
A-454 INTERIOR ELEVATIONS - TYP. LVL. GUEST CORRIDOR WESTWING
A-501 STAIR 1 DETAILS
A-502 STAIR 2 DETAILS
A-503 ELEVATOR DETAILS
A-504 ELEVATOR LOBBY DETAILS
A-505 CANOPY DETAILS
A-506 CANOPY DETAILS
A-507 ROOF DETAILS
A-508 ROOF DETAILS
A-509 EIFS DETAILS
A-510 TRANSITION, THRESHOLD, & CEILING DETAILS
A-511 ACCESSIBLE DETAILS
A-512 FIRE PENETRATION DETAILS
A-513 EXTERIOR WALL TYPES - EIFS
A-514 EXTERIOR WALL TYPES - STONE VENEER
A-515 EXTERIOR WALL TYPES
A-516 PARTITION TYPES
A-517 PARTITION TYPES
A-518 CEILING TYPES
A-519 DETAILS
A-520 CEILING- SUSPENDED GWB TYP. DETAILS
A-521 CEILING- SUSPENDED GWB TYP. DETAILS
A-601 WINDOW TYPES AND SCHEDULE
A-602 DOOR TYPES AND SCHEDULE
A-603 ROOM FINISH SCHEDULE
A-604 FINISH SCHEDULE
A-701 MILLWORK DETAILS- LOBBY TAP WALL
A-702 MILLWORK DETAILS- LOBBY AND GUEST STORAGE
A-703 MILLWORK DETAILS- FITNESS AND LOBBY
A-704 MILLWORK DETAILS- LOBBY AND PUBLIC
A-705 MILLWORK DETAILS- EMPLOYEE AND LAUNDRY LOUNGE
A-706 MILLWORK DETAILS- RECEPTION DESK PLAN AND OUTSIDEELEVATIONS
A-707 MILLWORK DETAILS- RECEPTION DESK SECTIONS ANDDETAILS
A-708 MILLWORK DETAILS- GUESTROOM KITCHENS
A-709 MILLWORK DETAILS- ACCESSIBLE GUESTROOM KITCHENS
A-710 MILLWORK DETAILS- MODIFIED FURNITURE
MECHANICAL
M-001 GENERAL MECHANICAL NOTES AND LEGENDS
M-100 GROUND FLOOR ZONE PLAN
M-101 GROUND FLOOR MECHANICAL PLAN
M-102 2ND FLOOR MECHANICAL PLAN
M-103 3RD FLOOR MECHANICAL PLAN
M-104 4TH FLOOR MECHANICAL PLAN
M-105 5TH FLOOR MECHANICAL PLAN
M-106 MECHANICAL ROOF PLAN
M-401 ENLARGED MECHANICAL PLANS
M-402 ENLARGED MECHANICAL PLANS
M-601 MECHANICAL CONTROL DIAGRAMS
M-701 MECHANICAL SCHEDULES
M-702 MECHANICAL SCHEDULES
M-703 MECHANICAL SCHEDULES
PLUMBING
P-100 UNDERFLOOR PLUMBING PLAN
P-101 GROUND FLOOR PLUMBING PLAN
P-102 2ND FLOOR PLUMBING PLAN
P-103 3RD FLOOR PLAUMBING PLAN
P-104 4TH FLOOR PLUMBING PLAN
P-105 5TH FLOOR PLUMBING PLAN
P-106 PLUMBING ROOF PLAN
P-111 GROUND FLOOR REFRIGERANT AND CONDENSATE PIPINGPLAN
P-112 2ND FLOOR REFRIGERANT AND CONDENSATE PIPING PLAN
P-113 3RD FLOOR REFRIGERANT AND CONDENSATE PIPING PLAN
P-114 4TH FLOOR REFRIGERANT AND CONDENSATE PIPING PLAN
P-115 5TH FLOOR REFRIGERANT AND CONDENSATE PIPING PLAN
P-401 ENLARGED PLUMBING PLANS
P-402 ENLARGED PLUMBING PLANS
P-403 ENLARGED WATER HEATER ROOM
P-501 PLUMBING DETAILS
P-502 PLUMBING DETAILS
P-601 WASTE AND VENT RISER DIAGRAM
P-602 WASTE AND VENT RISER DIAGRAM
P-603 DOMESTIC WATER RISER DIAGRAM
P-604 DOMESTIC WATER RISER DIAGRAM
P-605 CONDENSATE DRAIN RISER DIAGRAM
P-701 PLUMBING SCHEDULES
P-702 PLUMBING DETAILS
ELECTRICAL
E-001 ELECTRICAL SYMBOLS AND ABBREVIATIONS
E-002 EQUIPMENT SCHEDULES
E-003 EQUIPMENT SCHEDULES
E-004 LUMINAIRE SCHEDULES
E-005 LUMINAIRE SCHEDULES
E-101 ELECTRICAL SITE PLAN
E-102 ELECTRICAL SITE DETAILS
E-103 ELECTRICAL SITE DETAILS
E-104 STORAGE SHED ENLARGED ELECTRICAL PLAN
E-201A FIRST FLOOR LIGHTING PLAN - AREA A
E-201B FIRST FLOOR LIGHTING PLAN - AREA B
E-202A SECOND FLOOR LIGHTING PLAN - AREA A
E-202B SECOND FLOOR LIGHTING PLAN - AREA B
E-203A THIRD FLOOR LIGHTING PLAN - AREA A
E-203B THIRD FLOOR LIGHTING PLAN - AREA B
E-204A FOURTH FLOOR LIGHTING PLAN - AREA A
E-204B FOURTH FLOOR LIGHTING PLAN - AREA B
E-205A FIFTH FLOOR LIGHTING PLAN - AREA A
E-205B FIFTH FLOOR LIGHTING PLAN - AREA B
E-301A FIRST FLOOR ELECTRICAL PLAN - AREA A
E-301B FIRST FLOOR ELECTRICAL PLAN - AREA B
E-302A SECOND FLOOR ELECTRICAL PLAN - AREA A
E-302B SECOND FLOOR ELECTRICAL PLAN - AREA B
E-303A THIRD FLOOR ELECTRICAL PLAN - AREA A
E-303B THIRD FLOOR ELECTRICAL PLAN - AREA B
E-304A FOURTH FLOOR ELECTRICAL PLAN - AREA A
E-304B FOURTH FLOOR ELECTRICAL PLAN - AREA B
E-305A FIFTH FLOOR ELECTRICAL PLAN - AREA A
E-305B FIFTH FLOOR ELECTRICAL PLAN - AREA B
E-306 OVERALL ELECTRICAL ROOF PLAN
E-501 ENLARGED ELECTRICAL PLANS
E-502 ENLARGED ELECTRICAL PLANS
E-503 ENLARGED ELECTRICAL PLANS
E-504 ENLARGED POOL PHOTOMETRIC PLAN
E-601 POWER ONE-LINE DIAGRAM
E-602 POWER ONE-LINE DIAGRAM
E-603 PANEL SCHEDULES
E-604 PANEL SCHEDULES
E-605 PANEL SCHEDULES
E-606 PANEL SCHEDULES
E-607 PANEL SCHEDULES
E-608 PANEL SCHEDULES
E-609 PANEL SCHEDULES
E-610 PANEL SCHEDULES
E-611 PANEL SCHEDULES
E-612 PANEL SCHEDULES
E-701 ELECTRICAL DETAILS
E-702 ELECTRICAL DETAILS
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
REVISION SCHEDULE
# DESCRIPTION DATE
2 ADDENDUM 2 6/21/2024
2
A-1011 SIM
A101
A
NameElevation
0'4' 8'16'
SCALE: 1/8" = 1'-0"
Room name
101
150 SF
1
A-101
SIM
/1 A101
1 View Name1/8" = 1'-0"A101
SHEET REFERENCE
VIEW REFERENCE
CENTER LINE
ELEVATION TAG
GRID LINE
SHEET REFERENCE
VIEW REFERENCE
SECTION TAG
CL-A88'-88"
VIEW TITLE GRAPHIC SCALE
VIEW REFERENCE
SCALE
SHEET REFERENCE
NORTH ARROW
CEILING/SOFFIT/ROOF TAG
CALLOUT
VIEW REFERENCE
SHEET REFERENCE
REFERENCE AREA
SHEET REFERENCE
VIEW REFERENCE
SHEET REFERENCE
LEVEL TAG
LEVEL ELEVATION
LEVEL NAME
ROOM TAG
ROOM AREA
ROOM NAME
TYPE
DOOR TAG WINDOW / GLASS TAG
DOOR MARK
P1
WINDOW TYPE
WALL / PARTITION TAG
WALL TYPEP- PARTITIONX- EXTERIOR
1
REVISION TAG
REVISION CLOUD
REVISION TAG
1
A-101
SIM
WALL SECTION/DETAIL SECTION
SHEET REFERENCE
VIEW REFERENCE
1
Ref
1Ref 1 Ref1
Ref
CURTAIN WALL TAG
FLOOR TAG
MATERIAL TAG
KEYNOTE TAG
37
1i
1i
HEIGHT A.F.F.
Length
Time sec
PATH OF TRAVEL TAG
FURNITURE/LIGHT/CASEWORK TAG
1i
XXX-##
?XX-###
PATH OF TRAVEL INFORMATIONCURTAIN WALL MARK
KEYNOTE
ITEM MARKMATERIAL TYPE
FLOOR TYPE
GYPSUM WALL BOARD
CONCRETE
ASPHALT
WOOD SLATS
RIGID INSULATION
BATT INSULATION
STONE VENEER
EARTH
LUMBER
ANCHOR BOLT AIR CONDITIONINGACOUSTICAL TILEACOUSTICAL ABOVE FINISH FLOORALUMINUM ANODIZED ACCESS PANELAPPROXIMATEARCHITECTURAL BOARDBUILDINGBLOCKING BOTTOM CABINETCONTROL JOINT CEILING CLEAR CONC. MASONRY UNITCARBON MONOXIDE (DETECTOR)CLEAN OUT COLUMN CONCRETE CONTINUOUS CEMENT PLASTERCARPET CERAMIC TILECOURTYARD COLD WATER DETAILDRINKING FOUNTAIN DISPENSER DOOR DOOR OPENING DOWN DRAWING EASTEACH NO(S). OR # EXPANSION JOINTELECTRICAL ELEVATIONEQUAL EQUIPMENT EACH WAYELECTRIC WATER COOLEREXHAUST EXISTING EXPANSIONEXTERIOR FLOOR DRAIN FIRE EXTINGUISHER FIRE EXTINGUISHER CABINETFACTORY FINISH FINISH FIRE HOSE CABINET FLOORFACE OF CONCRETE FACE OF FINISH FACE OF MASONRY FACE OF STUDS FOOT OR FEET GAUGE GALVANIZED GALVANIZED IRON GLASS, GLAZING GYPSUM WALL BOARD GYPSUM HOSE BIBBHOLLOW CORE HANDICAPPED HARDWOODHARDWARE HOLLOW METALHOUR HEIGHT HEATING,VENTILATION& AIR CONDITIONING HOT WATER INSIDE DIAMETER INCLUDING INSULATIONINTERIOR JOINT KITCHEN LAMINATELAVATORY LIGHT GAUGE STEEL FRAMINGLIGHT MACHINE MATERIAL MAXIMUMMEMBRANE
A.B. AC ACT ACOUS. A.F.F. ALUM, AL ANOD. A.P.APPROX. ARCH. BD.BLDG. BLKG. BOT. CAB.C.J. CLG. CLR. CMUCO C.O. COL. CONC. CONT.C.P.CPT.C.T.CTYDCW DET.D.F.DISP.DR.D.O.DN.DWG.E.EA.E.J.ELEC.ELEV.EQ.EQUIP.E.W.E.W.C.EXH.EXIST.(E) EXP. EXT.F.D.F.E.F.E.C.F.F.FIN.F.H.C.FLR.F.O.C.F.O.F. F.O.M. F.O.S. FT. GA.GALV.G.I.GL.GWB GYP.H.B.H.C.HCHDWD.HDWR.H.M.HR.HGT.H.V.A.C.
HW I.D.INCL.INSUL. INT JT.KIT.LAM.LAV.LGSF.LT.MACH,MATL. MAX.MEMB.
METALMINIMUM MISCELLANEOUS NORTH NOT IN CONTRACT NUMBER(S)NOT TO SCALENON RATEDOBSCUREON CENTER OVERFLOW DRAINOWNER FURNISHCONTRACTOR INSTALLOWNER FURNISH OWNER INSTALL OPPOSITE PAINT PLANTER DRAIN PLATE PLASTIC LAMINATE PLASTER PLYWOOD PANEL PAPER TOWEL DISPENSER PAPER TOWEL RECEPTACLE QUARRY TILERADIUS RESILIENT BASE REFERENCE REINFORCING REQUIRED ROOM SOUTHSOLID CORE SCHEDULE SMOKE DETECTORSECTION SHEET SHEATHING SIMILAR SLOPE SLIDING SPECIFICATIONSQUARE STAINLESS STEEL SERVICE SINK STONE STANDARD STEEL STORAGE STRUCTURAL SUSPENDED SYMMETRICAL SYSTEM TREAD TELEPHONE TEMPERED THICK TOP OF FINISHED FLOORTOP OF PARAPET TOP OF STRUCTURAL SLABTOILET PAPER DISPENSERTOILET PAPER HOLDER TOP OF STEEL TYPICAL UNLESS OTHERWISE NOTEDURINAL VINYL COMPOSITION TILE VERTICAL VESTIBULE VENT THRU ROOF WESTWITH WALL COVERING WATER CLOSET WOOD WINDOW WATER HEATER WATERPROOF MEMBRANE SYSTEM
AND AT NUMBER ANGLE CENTER LINE PLUS OR MINUSDIAMETER OR ROUND
MET. MIN.MISC.N.N.I.C.N.T.S.N.R.OBSC.O.C.ODO.F.C.I.
O.F.O.I.OPP.PTP.D.PL.PLAM.PLAS.PLYWD.PNL.P.T.D. P.T.R.Q.T.PNL.R.B. REF.REINF.REQ.RMS..S.A.SCHED.SDSECT.SHT.SHTG. SIM.SL.SLDG. SPECSQ.S.S.S/S ST.STD.STL.STO. STRUC. SUSP. SYM. SYS.T. TEL.TEMP.THK.T.F.F. T.O.P. T.S.S. T.P.D. T.P.H.T.S.TYP. U.O.N.UR.V.C.T.VERT. VEST. V.T.R. W.W/ W.C.WC WD.WDW.W.H.WMS
&@#∠℄±⌀
MATCH LINE
SETBACK LINE
PROPERTY LINE
REFERENCE
WATERPROOFING
NOT USED
ADHESIVE
DEMOLISHED
CENTER LINE
BEYOND
LEVEL
OVERHEAD
GRID
HIDDEN
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216PROJECT INFORMATION
G-002
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216PROJECT INFORMATION
G-002
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
ZONING DATA - HOTELBUILDING CODE DATA - HOTEL
APPLICABLE CODES
MUNICIPAL AMENDMENTS:SPOKANE VALLEY MUNICIPAL CODE, TITLE 24(SVMC)
BUILDING CODE: 2018 INTERNATIONAL BUILDING CODEAS AMENDED BY CHAPTERS 19.27 AND 19.27A RCWCHAPTER 51-50 WAC (IBC 2018)
ENERGY CODE: 2018 WASHINGTON STATE ENERGY CODEAS AMENDED BY CHAPTERS 51-11C AND 51-11R WAC(WSEC 2018)
MECHANICAL CODE: 2018 INTERNATIONAL MECHANICAL CODE(IMC 2018)2018 INTERNATIONAL FUEL GAS CODE(IFGC 2018)NFPA 58 AND NFPA 54AS AMENDED BY CHAPTER 51-52 WAC
FIRE CODE:2018 INTERNATIONAL FIRE CODEAS AMENDED BY CHAPTERS 19.27 AND 34.05 RCWAND CHAPTER 51-54 WAC(IFC 2018)
PLUMBING CODE:2018 UNIFORM PLUMBING CODE AS AMENDED BY CHAPTER 51-56 WAC(UPC 2018)
ELECTRICAL CODE:2020 NATIONAL ELECTRICAL CODE (NFPA 70) ACCESSIBILITY:2010 AMERICANS WITH DISABILITIES ACT STANDARD FOR ACCESSIBLE DESIGN, THE FAIR HOUSING ACT DESIGN MANUAL AND 2009 ANSI A117.1.(ADA 2010)
CODE ANALYSIS
CONSTRUCTION TYPE:III-B (S)
SPRINKLERED:FULLY SPRINKLERED PER SECTION 903.3.1.1
OCCUPANCY:GROUND FLOORUPPER FLOORMAIN OCCUPANCIES:A-2, A-4, F-1, R-1, S-1 R-1ACCESSORY OCCUPANCIES: A-3, BS-1
CLIMATE ZONE:5B (DRY COOL)
ALLOWABLE AREA/HEIGHT/STORIESGROUND FLOOR (MIXED A-2, A-4, F-1, R-1, S-1) SPRINKLER SYSTEM:13/S/SMALLOWABLE TOTAL FLOOR AREA/STORY: 25,500 SFALLOWABLE NUMBER OF STORIES:3 STORIESALLOWABLE HEIGHT:75 FEET
PROPOSED FLOOR AREA/STORY:18,524 SFPROPOSED NUMBER OF STORIESWITH A-2, A-4, F-1, R-1, S-1:GROUND FLOOR
UPPER FLOORS (R-1) SPRINKLER SYSTEM:13/S/SMALLOWABLE TOTAL FLOOR AREA/STORY: 48,000 SFALLOWABLE NUMBER OF STORIES:5 STORIESALLOWABLE HEIGHT:75 FEET
PROPOSED FLOOR AREA/STORY:18,667 SFPROPOSED NUMBER OF STORIES:2ND-5TH FLOORSPROPOSED BUILDING HEIGHT:71' - 2"
TOTAL GROSS BUILDING AREA:93,192 SF
AVAILABLE EXITS:SEE CODE PLANS
FIRE RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS
BUILDING ELEMENTFIRE RESISTANCE RATINGPRIMARY STRUCTURAL FRAME0 HOURSBEARING WALLS*EXTERIOR2 HOURS (INSIDE EXP. PER 705.5)*INTERIOR0 HOURSNONBEARING WALLS AND PARTITION*EXTERIORSEE TABLE 602*INTERIOR0 HOURSFLOOR CONSTRUCTION0 HOURSROOF CONSTRUCTION0 HOURSSHAFTS2 HOURSELEVATOR ENCLOSURE2 HOURSSTAIR ENCLOSURE2 HOURSLINEN CHUTE, DRYER ROOMAND DISCHARGE ROOM2 HOURSBALCONIES/PROJECTIONS0 HOURS (PER 705.2.3.1, E.3&4)OPENINGS IN EXTERIOR WALLS0 HOURS (PER 602.1, T705.8)CORRIDOR WALLS1/2 HOUR (PER 708.4, E.1)DWELLING/SLEEPING UNIT SEPARATION 1/2 HOUR (PER 708.4, E.2)SMOKE BARRIER1 HOUR (PER T716.1(2))
TABLE 602: NON-BEARING EXTERIOR WALLS AND PARTITIONSFIRE SEPARATION DISTANCE CONST. TYPE OCC. F-1 & S-1 OCC. A & RX < 5'III-B2 HOURS 1 HOURX > OR = 5' AND < 10'III-B1 HOUR 1 HOURX > OR = 10' AND < 30' III-B1 HOUR 1 HOURX > OR = 30'III-B0 HOURS 0 HOURS
FIRE PROTECTION SYSTEMSSEE FIRE PROTECTION PLANS AND SPECIFICATIONS FOR INFORMATION REGARDING AUTOMATIC SPRINKLER SYSTEM DESIGN AND INSTALLATION. SEE ELECTRICAL DRAWINGS FOR INFORMATION REGARDING FIRE ALARM AND DETECTION SYSTEM DESIGN AND INSTALLATION.
APPLICABLE ZONING CODE
SPOKANE VALLEY MUNICIPAL CODE, TITLES 19, 22 AND ZONING MAP
ZONING CODE SUMMARY
PROJECT LOCATION: NORTH OF EAST CARLISLE AVENUE AND EAST OFNORTH MIRABEAU PARKWAY
PROJECT ADDRESS:13515 E CARLISLE AVENUESPOKANE VALLEY, WA 99216
PARCEL NUMBER:45101.0401
ZONING:MU (MIXED USE) IN SEPA INFILL
ADJACENT ZONING:POS, MU
PROPOSED USE:HOTEL
LOT AREA:3.26 AC (142,453 SF)
FLOOD ZONE:ZONE X
PARKING/LOADING
REQUIRED PARKING: 132 ROOMS @ 1 SPACE PER HOTEL ROOM 132 SPACES16 STAFF @ 1 SPACE PER STAFF ON THE LARGEST SHIFT16 SPACESTOTAL REQUIRED: 148 SPACES
PROPOSED PARKING: 116 STANDARD SPACES @ 9' - 0" X 18' - 0"28 COMPACT SPACES @ 8' - 0" X 18' - 0"5 STANDARD ACCESSIBLE SPACES @9' - 0" X 18' - 0" + 5' - 0" ACCESS AISLE1 VAN ACCESSIBLE SPACE @11' - 0" X 18' - 0" + 5' - 0" ACCESS AISLETOTAL PROVIDED: 150 SPACES
REQUIRED ELECTRIC VEHICLE INFRASTRUCTURE:149 SPACES @ 10% EV READYTOTAL REQUIRED: 15 SPACES WIRED FOR 208/240V, 40 AMP CHARGING
PROVIDED ELECTRICL VEHICLE INFRASTRUCTURE:16 SPACES (2/UNIT), INCLUDING 1 ACCESSIBLE SPACE WIRED FOR 208/240V, 40 AMP CHARGING
LOADING REQUIRED/PROVIDED:1 LOADING SPACE @ 12' - 0" X 30' - 0"
BICYCLE PARKING REQUIRED:3 BICYCLE RACKS FOR 2+ BICYCLES FOR 100-500 SPACES
BICYCLE PARKING PROVIDED:4 BICYCLE RACKS FOR 2 BICYCLES AT FRONT ENTRANCE
IMPERVIOUS SURFACES
TOTAL ROOF AREA:22,472 SFTOTAL ASPHALT/PAVING/CONCRETE/CURBS: 75,469 SF
PERCENT OF LOT COVERED BY BUILDING:15.78%
TOTAL IMPERVIOUS AREA COVERAGE:65.8% (93,492 SF)
ENERGY CODE
BUILDING ELEMENTMINIMUM INSULATION VALUEEXTERIOR WALLSR-20 STD + 3.8 CIBELOW-GRADE WALL R-25 OR R-20 STD + 3.8 CCANTILEVERED FLOORS R-30UNHEATED SLABR-10 FOR 24" BELOWROOF R-38 CIROOF (TAPERED INSUL.) R-38 EQUIVALENT PER WSEC TABLE A102.2.6(1) AND (2)MINIMUM R-VALUE AT VALLEY: R-22.5 (4" INSULATION)MAXIMUM CODE-ALLOWED R-VALUE: R-60
ANNOTATION LEGEND ABBREVIATION LEGEND
LINE TYPES
CODE ANALYSIS
CONSTRUCTION TYPE:V-B (NS)
SPRINKLERED:NO
OCCUPANCY:S-1
PROPOSED USE:STORAGE
CLIMATE ZONE:5B (DRY COOL)
ALLOWABLE AREA/HEIGHT/STORIESSPRINKLER SYSTEM:NSALLOWABLE TOTAL FLOOR AREA/STORY: 9,000 SFALLOWABLE NUMBER OF STORIES:1 STORYALLOWABLE HEIGHT:40 FEET
PROPOSED FLOOR AREA/STORY:253 SFPROPOSED NUMBER OF STORIES1 STORY
TOTAL GROSS COVERED BUILDING AREA:253 SF
QUALIFIES AS A LOW-ENERGY BUILDING: C402.1.1 (1): <1 WATT/SF ENERGY USAGE
FIRE RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS
BUILDING ELEMENTFIRE RESISTANCE RATINGPRIMARY STRUCTURAL FRAME0 HOURSBEARING WALLS*EXTERIOR0 HOURS*INTERIOR0 HOURSNONBEARING WALLS AND PARTITION*EXTERIORSEE TABLE 602*INTERIOR0 HOURSFLOOR CONSTRUCTION0 HOURSROOF CONSTRUCTION0 HOURS
FIRE-RESISTANCE RATING REQUIREMENTS FOR EXTERIOR WALLS (TABLE 602):REQUIREMENTS BELOW SHALL BE FOLLOWED FOR ALL NEW CONSTRUCTION
FIRE SEPARATION DISTANCE CONST. TYPE OCC. S-1X < 5'V-B2 HOURSX > OR = 5' AND < 10'V-B1 HOURX > OR = 10' AND < 30' V-B0 HOURS X > OR = 30'V-B0 HOURS
FIRE PROTECTION SYSTEMSSEE ELECTRICAL DRAWINGS FOR INFORMATION REGARDING FIRE ALARM AND DETECTION SYSTEM DESIGN AND INSTALLATION.
BUILDING & ZONING CODE DATA - STORAGE/TRASH ENCLOSUREPLUMBING FIXTURE CALCS
•••••••
POOL & SPLASH PADKITCHENFIRE SPRINKLERSFIRE ALARMELEVATORSSOLARNON-RESIDENTIAL ENERGY CODE (ENGAGEMENT LETTER SUBMITTED)N PINES ROADN PINES ROADFREEWAYFREEWAY
E TRENTE TRENTAVEAVE
SP
O
K
A
N
E
S
P
O
K
A
N
E
RIV
E
R
R
I
V
E
R
SP
O
K
A
N
E
S
P
O
K
A
N
E
RIV
E
R
R
I
V
E
R
E. BROADWAY AVE.
SPOKANE VALLEYSPOKANE VALLEY
MALLMALL
E. MANSFIELD AVE.
E. INDIANA AVE.
E MISSION AVE.
E BROADWAY AVE.
E. CARLISLE AVE.N. M
IRABEAU
PKWY
.
VICINITY MAPNTS
PROJECT LOCATION13515 E. CARLISLE AVE.
MATERIAL LEGEND
PROVIDED4.54.5 3.5 3.5 2
TOTAL REQUIRED ROUNDED UP35 1 2 1
TOTAL REQUIRED2.234.035 0.57 1.65 0.772
9 OCC/GENDER0.090.09 0.09 0.018
S-1: STORAGE AND SERVICE1 WC PER 100 PEOPLE 1 LAV. PER 100 PEOPLE 1 D.F. PER 1,000 PEOPLE
3 OCC./GENDER0.120.12 0.075 0.06
B: BUSINESS1 WC PER 25 PEOPLE 1 LAV. PER 40 PEOPLE 1 D.F. PER 100 PEOPLE
58 OCC./GENDER0.7731.45 0.29 0.387 0.116
A4: POOL1 WC PER 75 PEOPLE 1 WC PER 40 PEOPLE 1 LAV. PER 200 PEOPLE 1 LAV. PER 150 PEOPLE 1 D.F. PER 1,000 PEOPLE
9 OCC./GENDER0.120.225 0.045 0.06 0.018
A3: FITNESS1 WC PER 75 PEOPLE 1 WC PER 40 PEOPLE 1 LAV. PER 200 PEOPLE 1 LAV. PER 150 PEOPLE 1 D.F. PER 1,000 PEOPLE
140 OCC./GENDER1.122.15 0.7 0.56
A2: PUBLIC SPACES1 WC PER 125 PEOPLE 1 WC PER 65 PEOPLE 1 LAV. PER 200 PEOPLE 1 D.F. PER 500 PEOPLE
MENWOMEN MEN WOMEN
WATER CLOSETS LAVATORY DRINKING FOUNTAIN
DEFERRED SUBMITTALS
NOTE:
PROVIDED TOILET STALLS INCLUDE MEN'S AND WOMEN'S RESTROOMS AS WELL AS 1 UNISEX PUBLIC RESTROOM AND TWO DEDICATED STALLS FOR STAFF LOCATED IN THE EMPLOYEE BREAKROOM.
ALL HOTEL GUESTS ALSO HAVE ACCESS TO BATHROOMS IN THEIR GUESTROOMS.
TWO BOTTLE FILLERS AND AN ICE MACHINE WITH A WATER SPIGOT ARE PROVIDED FOR GUEST USE, ONE IN THE LOBBY, ONE IN THE ICE/WATER ROOM AND ONE IN THE FITNESS ROOM. EACH WILL HAVE CUPS PROVIDED FOR GUEST USE IF THEY DO NOT HAVE A WATER BOTTLE.
ENGINEERED GRADING PERMIT:EGR-2024-0041NOTE: ALL CIVIL DRAWINGS SUBMITTED AS PART OF THIS PERMIT, NO CIVIL DRAWINGS TO BE SUBMITTED AS PART OF BLD-2024-0696
STORAGE SHED AND TRASH ENCLOSURE BUILDING PERMIT: BLD-2024-0697NOTE: ALL DRAWINGS BEING SUBMITTED THROUGH PERMIT BLD-2024-0696
ASSOCIATED PERMITS
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
REVISION SCHEDULE
# DESCRIPTION DATE
2 ADDENDUM 2 6/21/2024
REVISION SCHEDULE
# DESCRIPTION DATE
2 ADDENDUM 2 6/21/2024
2
BAL.
CONNECTING
K1B: ENL.SHOWER
BAL.
CONNECTING
K1B: ENL.SHOWER
BAL.
CONNECTING
K1B: ADAADA TUB
BAL.
CONNECTING
K1B: ENL.SHOWER
BAL.
CONNECTING
K1BSHOWER
BAL.
CONNECTING
K1BSHOWER
BAL.
CONNECTING
K1BSHOWER
BAL.
CONNECTING
K1BSHOWER
5TH FLOOR
4TH FLOOR
3RD FLOOR
2ND FLOOR
1ST FLOOR
X01X02X03X04X05X06X07X08X09X10X11X12X13X14X15X16X18X19X20X21X22
CONNECTING
ES: ADAADA TUB
CONNECTING
ES: ADAR-I SHWR
CONNECTING
ES: ENL.SHOWER
CONNECTING
ES: ENL.SHOWER
CONNECTING
KSSHOWER
CONNECTING
KSSHOWER
CONNECTING
KSSHOWER
CONNECTING
KSSHOWER
CONNECTING
ESSHOWER
CONNECTING
ESSHOWER
ESSHOWER
CONNECTING
ESSHOWER
BOHPUBLICSTAIR
STAIR
STAIR
STAIR
STAIR
CONNECTING
ESSHOWER
CONNECTING
ESSHOWER
CONNECTING
ESSHOWER
BOH
BOH
CONNECTING
ESSHOWER
CONNECTING
ESSHOWER
CONNECTING
ESSHOWER
CONNECTING
ESSHOWER
BOH
BOH
BOH
BOH
CONNECTING
DQSSHOWER
CONNECTING
DQSSHOWER
CONNECTING
DQSSHOWER
CONNECTING
DQSSHOWER
ELEV.
ELEV.
ELEV.
ELEV.
ELEV.
ELEV.
ELEV.
ELEV.
ELEV.
ELEV.
CONNECTING
DQS: ENL.SHOWER
CONNECTING
DQS: ENL.SHOWER
CONNECTING
DQS: ENL.SHOWER
CONNECTING
DQS: ADAADA TUB
PUBLICPUBLIC
CONNECTING
KSSHOWER
CONNECTING
KSSHOWER
CONNECTING
KSSHOWER
CONNECTING
KSSHOWER
CORR.
CORR.
CORR.
CORR.
CORR.
CONNECTING
KSSHOWER
CONNECTING
KSSHOWER
CONNECTING
KSSHOWER
CONNECTING
KSSHOWER
X17
ELEV. LOBBY
ELEV. LOBBY
ELEV. LOBBY
ELEV. LOBBY
ELEV. LOBBYPUBLIC
CONNECTING
KSSHOWER
CONNECTING
KSSHOWER
CONNECTING
KSSHOWER
CONNECTING
KSSHOWER
BAL.
CONNECTING
KSSHOWER
BAL.
CONNECTING
KSSHOWER
BAL.
CONNECTING
KSSHOWER
BAL.
CONNECTING
KSSHOWER
CONNECTING
KSSHOWER
CONNECTING
KSSHOWER
CONNECTING
KSSHOWER
CONNECTING
KSSHOWER
BAL.
CONNECTING
KSSHOWER
BAL.
CONNECTING
KSSHOWER
BAL.
CONNECTING
KSSHOWER
BAL.
CONNECTING
KSSHOWER
CONNECTING
DQSBATHTUB
CONNECTING
DQSBATHTUB
CONNECTING
DQSBATHTUB
CONNECTING
DQSBATHTUB
X23
BAL.
CONNECTING
KSSHOWER
BAL.
CONNECTING
KSSHOWER
BAL.
CONNECTING
KSSHOWER
BAL.
CONNECTING
KSSHOWER
X24
CONNECTING
DQSBATHTUB
CONNECTING
DQSBATHTUB
CONNECTING
DQSBATHTUB
CONNECTING
DQSBATHTUB
X25
BAL.
CONNECTING
KSSHOWER
BAL.
CONNECTING
KSSHOWER
BAL.
CONNECTING
KSSHOWER
BAL.
CONNECTING
KSSHOWER
X26
CONNECTING
KSSHOWER
CONNECTING
KSSHOWER
CONNECTING
KSSHOWER
CONNECTING
KSSHOWER
X27
CONNECTING
ESSHOWER
CONNECTING
ESSHOWER
CONNECTING
ESSHOWER
CONNECTING
ESSHOWER
X28
CONNECTING
ESSHOWER
CONNECTING
ESSHOWER
CONNECTING
ESSHOWER
CONNECTING
ESSHOWER
X29
CONNECTING
ESSHOWER
CONNECTING
ESSHOWER
CONNECTING
ESSHOWER
CONNECTING
ESSHOWER
ESSHOWER
X30
CONNECTING
KSSHOWER
CONNECTING
KSSHOWER
CONNECTING
KSSHOWER
CONNECTING
KSSHOWER
KSSHOWER
X31
CONNECTING
ESSHOWER
CONNECTING
ESSHOWER
CONNECTING
ESSHOWER
CONNECTING
ESSHOWER
CONNECTING
ESSHOWER
X32
STAIR
STAIR
STAIR
STAIR
STAIR
X33
CONNECTING
ESSHOWER
CONNECTING
ESSHOWER
CONNECTING
ESSHOWER
CONNECTING
ESSHOWER
CONNECTING
ESSHOWER
X34
ESSHOWER
ESSHOWER
ESSHOWER
ESSHOWER
ESSHOWER
X35
BAL.
CONNECTING
DQSSHOWER
BAL.
CONNECTING
DQSSHOWER
BAL.
CONNECTING
DQSSHOWER
BAL.
CONNECTING
DQSSHOWER
BAL.
CONNECTING
DQSSHOWER
X36
CONNECTING
DQSBATHTUB
CONNECTING
DQSBATHTUB
CONNECTING
DQSBATHTUB
CONNECTING
DQSBATHTUB
CONNECTING
DQSBATHTUB
X37
BAL.
CONNECTING
KSSHOWER
BAL.
CONNECTING
KSSHOWER
BAL.
CONNECTING
KSSHOWER
BAL.
CONNECTING
KSSHOWER
BAL.
CONNECTING
KSSHOWER
X38
CONNECTING
KS: ENL.SHOWER
CONNECTING
KS: ENL.SHOWER
CONNECTING
KS: ADAR-I SHWR
CONNECTING
KS: ADAADA TUB
CONNECTING
KS: ADAADA TUB
ABBREVIATIONS / LEGEND:
ADA TUB ACCESSIBLE BATHTUB
BOH BACK-OF-HOUSE
CORR. CORRIDOR
DQS DOUBLE QUEEN SUITE
ELEV. ELEVATOR
ENL. ENLARGED
ES EFFICIENCY SUITE
BAL.
KS KING STUDIO SUITE
K1B KING 1-BEDROOM SUITE
R-I SHWR ROLL-IN SHOWER
COMMUNICATION FEATURE ROOM
ACCESSIBLE MOBILITY ROOM
BALCONY
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216BUILDINGDEVELOPMENTINFORMATION
G-003
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
ROOM COUNT BREAKDOWN
VERTICAL ROOM CHART
GENERAL NOTES BUILDING AREA PROGRAM
TOTAL ROOMS BY FLOOR 9 30 31 31 31 132
KING ONE-BEDROOM SUITE - ACCESSIBLE (TUB)- - 1 - -1
KING ONE-BEDROOM SUITE - 2 1 2 2 7 6.06%
DOUBLE QUEEN STUDIO SUITE - ACCESSIBLE (TUB)- - - - 1 1
DOUBLE QUEEN STUDIO SUITE 2 6 6 6 5 25 19.70%
KING STUDIO SUITE - ACCESSIBLE (ROLL-IN)- - 1 - -1
KING STUDIO SUITE - ACCESSIBLE (TUB)1 1 - - -2
KING STUDIO SUITE 2 12 12 13 13 52
41.67%
EFFICIENCY SUITE - ACCESSIBLE (ROLL-IN)- - - 1 -1
EFFICIENCY SUITE - ACCESSIBLE (TUB)- - - - 1 1
EFFICIENCY SUITE 4 9 10 9 9 41
32.58%
ROOM TYPE 1STFLOOR 2NDFLOOR 3RDFLOOR 4THFLOOR 5THFLOOR # BYTYPE % BYTYPE
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
THE FOLLOWING GENERAL NOTES ARE APPLICABLE THROUGHOUT THESE CONSTRUCTION DRAWINGS.
NOTHING SET FORTH IN THESE DRAWINGS SHALL RELEASE THE CONTRACTOR FROM ITS RESPONSIBILITY TO PROVIDE APPROPRIATE QUANTITIES, FIELD MEASUREMENTS, DIMENSIONAL STABILITY, INSTALLATION, ANCHORAGE, AND COORDINATION WITH ALL OTHER SUBCONTRACTORS AND TRADES, OR RELEASE THE CONTRACTOR OF RESPONSIBILITY TO IDENTIFY AND RESOLVE DEVIATIONS FROM THE REQUIREMENTS OF THESE DOCUMENTS OR RELEASE THE CONTRACTOR OF RESPONSIBILITY TO ALERT THE ARCHITECT TO ERRORS OR OMISSIONS CONTAINED THEREIN.
THE CONTRACTOR SHALL WARRANT TO THE OWNER THAT ALL MATERIALS AND EQUIPMENT FURNISHED AND INSTALLED UNDER THIS CONTRACT SHALL BE NEW, UNLESS OTHERWISE SPECIFIED, AND THAT ALL WORK SHALL BE OF GOOD QUALITY, FREE FROM DEFECTS AND FAULTS, AND CONFORMS TO THE CONTRACT DOCUMENTS.
THE CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS IN THE FIELD PRIOR TO COMMENCING WORK, AND SHALL REPORT ANY DISCREPANCIES BETWEEN DRAWINGS, SPECIFICATIONS AND FIELD CONDITIONS REQUIRING MODIFICATIONS TO THE ARCHITECT BEFORE PROCEEDING. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL COSTS ASSOCIATED WITH, OR CAUSED BY ITS FAILURE TO COMPLY WITH THIS REQUIREMENT.
THE CONTRACTOR SHALL COORDINATE ALL WORK PROCEDURES WITH REQUIREMENTS OF LOCAL AUTHORITIES AND/OR BUILDING MANAGEMENT.
THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROTECTION OF ALL CONDITIONS AND MATERIALS WITHIN THE PROPOSED CONSTRUCTION AREA. THE CONTRACTOR SHALL DESIGN AND INSTALL REQUISITE SHORING AND BRACING FOR ALL STRUCTURAL OR REMOVAL TASKS. THE CONTRACTOR SHALL HAVE SOLE RESPONSIBILITY FOR ANY DAMAGE OR INJURIES CAUSED BY OR DURING THE EXECUTION OF THE WORK.
THE CONTRACTOR SHALL COORDINATE AND WORK WITH ALL TRADES ON THE PROJECT NOT UNDER CONTRACT TO THE CONTRACTOR (I.E. TELEPHONE, DATA LINES, ETC.). ANY CHANGES OR DELAYS ARISING FROM CONFLICTS WITH SUCH TRADES SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR AT NO ADDITIONAL EXPENSE TO THE OWNER.
THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR, AND HAVE CONTROL OVER, ALL CONSTRUCTION MEANS, TECHNIQUES, SEQUENCES AND PROCEDURES AND FOR COORDINATING ALL PORTIONS OF THE WORK REQUIRED BY THE CONTRACT DOCUMENTS.
THE DRAWINGS ARE THE GRAPHIC AND PICTORIAL PORTIONS OF THE CONTRACT DOCUMENTS, WHEREVER LOCATED AND WHENEVER ISSUED, SHOWING THE DESIGN, LOCATION AND DIMENSIONS OF THE WORK, GENERALLY INCLUDING PLANS, ELEVATIONS, SECTIONS, DETAILS, SCHEDULES AND DIAGRAMS. THE DRAWINGS WILL SHOW DIMENSIONS, POSITION AND KIND OF CONSTRUCTION.
THE SPECIFICATIONS ARE THAT PORTION OF THE CONTRACT DOCUMENTS CONSISTING OF THE WRITTEN REQUIREMENTS FOR MATERIALS, EQUIPMENT, CONSTRUCTION SYSTEMS, STANDARDS AND WORKMANSHIP FOR THE WORK, AND PERFORMANCE OF RELATED SERVICES. THE SPECIFICATIONS WILL SHOW THE QUALITIES AND METHODS.
ANY WORK CALLED FOR ON THE DRAWINGS AND MENTIONED IN THE SPECIFICATIONS OR VICE VERSA, SHALL BE PERFORMED AS THOUGH FULLY SET FORTH IN BOTH. WORK NOT PARTICULARLY DETAILED, MARKED OR SPECIFIED SHALL BE THE SAME AS SIMILAR PARTS THAT ARE DETAILED, MARKED OR SPECIFIED.
CONTRACTOR TO VERIFY AND CHECK ALL DIMENSIONS AND DETAILS SHOWN ON THE DRAWINGS. SHOULD AN ERROR, DISCREPENCY OR AMBIGUITY APPEAR IN THE DRAWINGS OR SPECIFICATIONS OR IN THE WORK DONE BY OTHERS AFFECTING THIS WORK, THE CONTRACTOR SHALL NOTIFY THE CONSTRUCTION MANAGER AND ARCHITECT AT ONCE, THE CONSTRUCTION MANAGER AND ARCHITECT WILL THEN ISSUE WRITTEN INSTRUCTIONS AS TO PROCEDURE. IF THE CONTRACTOR PROCEEDS WITH THE WORK AS AFFECTED, WITHOUT INSTRUCTIONS FROM THE CONSTRUCTION MANAGER AND ARCHITECT, HE DOES SO AT HIS OWN RISK AND EXPENSE. THIS INCLUDES TYPOGRAPHICAL ERRORS ON THE DRAWINGS WHERE THEY OCCUR AND DOUBTFUL INTERPRETATIONS. FIGURED DIMENSIONS ON THE SCALED DRAWINGS AND THE LARGER SIZE DRAWINGS SHALL TYPICALLY GOVERN.
WHERE ON ANY DRAWINGS A PORTION OF THE WORK IS DRAWN OUT AND THE REMAINDER IS INDICATED IN OUTLINE, THE DRAWN OUT PARTS SHALL APPLY TO ALL LIKE PORTIONS OF THE WORK. WHERE ORNAMENT OR OTHER DETAIL IS INDICATED BY STARTING ONLY, SUCH DETAIL SHALL BE CONTINUED THROUGHOUT THE COURSES OR PARTS IN WHICH IT OCCURS AND SHALL APPLY TO ALL OTHER SIMILAR PARTS IN THE WORK UNLESS OTHERWISE INDICATED.
14.
15.
16.
17.
18.
19.
20.
21.
22.
23.
24.
25.
26.
27.
28.
DETAILS NOT SHOWN ARE SIMILAR IN CHARACTER TO THOSE THAT ARE. WHERE SPECIFICATIONS, DIMENSIONS, DETAILS OR DESIGN INTENT CANNOT BE DETERMINED, CONSULT THE ARCHITECT BEFORE PROCEEDING WITH WORK.
FOR CONVENIENCE, THE SPECIFICATIONS AND DRAWINGS ARE ARRANGED IN SEVERAL DIVISIONS AND SECTIONS, BUT SUCH SEPARATIONS SHALL NOT BE CONSIDERED AS THE LIMITS OF THE WORK REQUIRED FOR ANY SUBCONTRACT OR TRADE. THE TERMS AND CONDITIONS OF SUCH LIMITATIONS ARE WHOLLY BETWEEN EACH CONTRACTOR AND HIS SUBCONTRACTORS. EACH CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL SUBCONTRACT ARRANGEMENTS OF WORK REGARDLESS OF THE LOCATION OF PROVISIONS IN THE SPECIFICATIONS.
SCHEDULES OF WORK INCLUDED IN THESE GENERAL NOTES ARE GIVEN FOR CONVENIENCE ONLY AND SHALL NOT BE CONSIDERED AS A COMPREHENSIVE LIST OF ITEMS NECESSARY TO COMPLETE THE WORK.
WHERE DEVICES OR ITEMS OR PARTS THEREOF ARE REFERRED TO IN THE SINGULAR, IT IS INTENDED THAT SUCH REFERENCES SHALL APPLY TO AS MANY SUCH DEVICES, ITEMS OR PARTS AS ARE REQUIRED TO PROPERLY COMPLETE THE WORK.EACH SECTION OF THE SPECIFICATIONS IS GOVERNED BY APPLICABLE REQUIREMENTS OF THE CONTRACT DOCUMENTS AS IF HEREIN WRITTEN.
THE CONTRACTOR SHALL LAYOUT HIS OWN WORK AND SHALL PROVIDE ALL DIMENSIONS REQUIRED FOR OTHER TRADES (PLUMBING, ELECTRICAL, ETC.)
THE CONTRACTOR SHALL COORDINATE WITH OWNER'S VENDORS, CONTRACTORS AND STAFF FOR SCHEDULING, ACCESS, AND/OR REMOVAL AND INSTALLATION OF ALL ASSOCIATIVE EQUIPMENT, FURNISHINGS AND APPLIANCES WITHIN THE WORK AREA. MECHANICAL, PLUMBING AND ELECTRICAL WORK SHALL BE PERFORMED BY PERSONS LICENSED IN THEIR TRADES.
THE CONTRACTOR MUST SUBMIT TO THE OWNER FOR APPROVAL A BARRICADE PLAN BASED ON THE FENCING SHOWN ON THE CIVIL DRAWINGS, SHOWING SAFE INGRESS AND EGRESS FOR GUESTS DURING THE CONSTRUCTION PERIOD. SAFETY OF THE JOBSITE SHALL BE THE SOLE RESPONSIBILITY OF THE CONTRACTOR.
THE CONTRACTOR SHALL PERFORM ALL CUTTING, PATCHING AND REPAIRING AS REQUIRED TO PROVIDE WORK INDICATED ON THE DRAWINGS AND ALL OTHER WORK THAT MAY BE REQUIRED TO COMPLETE THE JOB.
REFER TO STRUCTURAL, MECHANICAL, PLUMBING, FIRE SAFETY AND ELECTRICAL DRAWINGS AND SPECIFICATIONS. FOR ADDITIONAL GENERAL NOTES, ABBREVIATIONS AND SYMBOLS LEGENDS, ALL NOTES ARE TO BE REVIEWED AND APPLIED TO RELATED BUILDING COMPONENTS.
NOTES APPEAR ON VARIOUS SHEETS FOR DIFFERENT SYSTEMS AND MATERIALS. SHEETS ARE TO BE REVIEWED AND NOTES ON ANY ONE DRAWING ARE TO BE APPLIED TO RELATED SYSTEMS AND MATERIALS DEPICTED ON OTHER DRAWINGS.
IT IS THE INTENTION OF THE KEY NOTES LOCATED ON THE VARIOUS SHEET(S) WITHIN THIS DRAWING SET TO IDENTIFY CONSTRUCTION ELEMENTS, NOT NECESSARILY DESCRIBE ENTIRE ASSEMBLIES OR PROCESSES. THE INSTALLATION OF SAID ELEMENT SHOULD INCLUDE ALL ASSOCIATED CONSTRUCTION NECESSARY TO ACHIEVE INSTALLATION AND OPERATION (USE) OF SAID ITEM. FOR EXAMPLE, THE INSTALLATION OF CERAMIC TILE SHALL INCLUDE (BUT BE NOT LIMITED TO) THE SURFACE PREPARATION, MASTIC, GROUT, EDGE STRIPS, SEALING, CLEANING, ETC. IN ADDITION, IF THE PLUMBER INSTALLS A LAVATORY, IT MEANS HE/SHE SHALL PREPARE SURFACE(S), SET LAVATORY, SEAL AROUND BOWL, PROVIDE FAUCET, CONNECT TO PLUMBING AS NECESSARY TO ACHIEVE AN AESTHETICALLY PLEASING, ACCESSIBLE (WHERE INDICATED), OPERATIONAL LAVATORY UPON COMPLETION OF THE PROJECT.
ALL ELEVATIONS ARE BASED ON 0.00' REFERENCING A GRADE LEVEL OF 0.00' EXCEPT FOR ELEVATIONS THAT REFERENCE A.F.F (ABOVE FINISHED FLOOR) OR OTHER SPECIFIC INDICATOR.
DIMENSIONS SHOWN ARE FOR REFERENCE AND ARE TO COMMUNICATE CRITICAL AREAS FOR DESIGN INTENT. FINAL DRAWINGS MAY VARY BASED ON CONSTRUCTION PRACTICES, LOCAL CODE REQUIREMENTS OR SPECIFIC SITE REQUIREMENTS.
REFERENCE DIMENSION (RD) THESE DIMENSIONS ARE PROVIDED FOR GENERAL REFERENCE ONLY. ACTUAL DIMENSION MAY VARY BASED ON CONSTRUCTION METHOD.
ROOM SIZES AND AREAS
NOTE: ALL SIZES SPECIFIED IN THIS SECTION ARE THE MINIMUM SIZE FOR THAT ROOM TYPE ON THIS PROJECT, SOME ROOMS OF THE TYPE MAY BE LARGER.
ACCESSIBLE ROOM MATRICIES
KING ONE-BEDROOM SUITE - ACCESSIBLE / ENLARGED 26'-6" x 27'-6" 716 SF
KING ONE-BEDROOM SUITE 24'-11" x 25'-1" 619 SF
DOUBLE QUEEN STUDIO SUITE - ACCESSIBLE /...18'-8" x 30'-6" 562 SF
DOUBLE QUEEN STUDIO SUITE 18'-5" x 29'-6" 537 SF
KING STUDIO SUITE - ACCESSIBLE / ENLARGED 18'-8" x 26'-5" 483 SF
KING STUDIO SUITE 18'-5" x 23'-2" 420 SF
EFFICIENCY SUITE - ACCESSIBLE / ENLARGED 14'-9" x 27'-6" 400 SF
EFFICIENCY SUITE 14'-3" x 25'-2" 353 SF
ROOM TYPE MINIMUM ROOMDIMENSIONS MINIMUMAREA
TOTAL 7 7
KING ONE-BEDROOM SUITE - BATHTUB & BALCONY 1 301
DOUBLE QUEEN STUDIO SUITE - BATHTUB 1 513
EFFICIENCY SUITE - BATHTUB 1 503
KING STUDIO SUITE - BATHTUB
5
2 138, 238
EFFICIENCY SUITE - ROLL-IN SHOWER 1 403
KING STUDIO SUITE - ROLL-IN SHOWER 2 1 338
ROOM TYPE REQUIREDCOUNT PROVIDEDCOUNT ROOMNUMBERS
MOBILITY ACCESSIBLE ROOMS
TOTAL 12 12
KING ONE-BEDROOM SUITE 1 202
DOUBLE QUEEN STUDIO SUITE - BATHTUB 1 322
DOUBLE QUEEN STUDIO SUITE - BALCONY 1 435
EFFICIENCY SUITE - ENLARGED 1 303
EFFICIENCY SUITE 3 133, 428, 508
KING STUDIO SUITE - BALCONY 2 325, 519
KING STUDIO SUITE
11
2 404, 530
KING STUDIO SUITE - MOBILITY ACCESSIBLE (BATHTUB) 1 1 238
ROOM TYPE REQUIREDCOUNT PROVIDEDCOUNT ROOMNUMBERS
COMMUNICATION FEATURE ROOMS
BACK OF HOUSE
ACCESSIBLE EMPLOYEE RESTROOM (GROUND FLOOR)1 50 SF 50 SF
ATTIC ACCESS (5TH FLOOR)1 67 SF 67 SF
BOH DRYERS (GROUND FLOOR)1 84 SF 84 SF
BOH LAUNDRY (GROUND FLOOR)1 750 SF 750 SF
DAC CLOSET (TYPICAL FLOOR)4 6 SF 26 SF
ELECTRICAL CLOSET (TYPICAL FLOOR)5 10 SF 49 SF
ELECTRICAL MAIN ROOM (GROUND FLOOR)1 548 SF 548 SF
ELECTRICAL ROOM (GROUND FLOOR)1 135 SF 135 SF
EMPLOYEE RESTROOM (GROUND FLOOR)1 30 SF 30 SF
EMPLOYEE ROOM (GROUND FLOOR)1 432 SF 432 SF
ENGINEERING OFFICE AND STORAGE (2ND FLOOR)1 255 SF 255 SF
FOOD PREP (GROUND FLOOR)1 594 SF 594 SF
GENERAL MANAGER'S OFFICE (GROUND FLOOR)1 95 SF 95 SF
HOUSEKEEPING OFFICE (GROUND FLOOR)1 56 SF 56 SF
ICE/WATER (GROUND FLOOR)1 17 SF 17 SF
IDF CLOSET (TYPICAL FLOOR)4 5 SF 19 SF
LAUNDRY LOUNGE (GROUND FLOOR)1 257 SF 257 SF
LINEN CHUTE (TYPICAL FLOOR)1 13 SF 13 SF
LINEN DISCHARGE AND SORTING ROOM (GROUND FLOOR) 1 131 SF 131 SF
LINEN STORAGE (GROUND FLOOR)1 85 SF 85 SF
LINENS & HOUSEKEEPING (TYPICAL FLOOR)4 497 SF 1,989 SF
MEETING STORAGE (GROUND FLOOR)1 81 SF 81 SF
OPEN OFFICE (GROUND FLOOR)1 233 SF 233 SF
OWNER'S OFFICE (GROUND FLOOR)1 104 SF 104 SF
PANELS (TYPICAL FLOOR)4 37 SF 148 SF
PBX/MDF ROOM (GROUND FLOOR)1 98 SF 98 SF
POOL MECHANICAL ROOM (GROUND FLOOR)1 204 SF 204 SF
SALES OFFICE (GROUND FLOOR)1 106 SF 106 SF
WATER HEATER & FIRE ROOM (GROUND FLOOR)1 361 SF 361 SF
45 7,018 SF
GUEST SUITE BALCONIES/LANAI
BALCONY (TYPICAL FLOOR)32 VARIES 1,841 SF
LANAI (GROUND FLOOR)2 54 SF 109 SF
34 1,950 SF
GUEST SUITES
DOUBLE QUEEN SUITE 22 VARIES 11,862 SF
DOUBLE QUEEN SUITE - ENLARGED 3 568 SF 1,705 SF
DOUBLE QUEEN SUITE - MOBILITY ACCESSIBLE - BATHTUB 1 565 SF 565 SF
EFFICIENCY SUITE 39 VARIES 13,821 SF
EFFICIENCY SUITE - ENLARGED 2 402 SF 804 SF
EFFICIENCY SUITE - MOBILITY ACCESSIBLE - BATHTUB 1 399 SF 399 SF
EFFICIENCY SUITE - MOBILITY ACCESSIBLE - ROLL-IN SHOWER 1 399 SF 399 SF
KING 1-BEDROOM SUITE 4 619 SF 2,476 SF
KING 1-BEDROOM SUITE - MOBILITY ACCESSIBLE - BATHTUB 1 712 SF 712 SF
KING 1-BEDROOM SUITE- ENLARGED 3 716 SF 2,149 SF
KING STUDIO SUITE 50 VARIES 21,045 SF
KING STUDIO SUITE - ENLARGED 2 487 SF 973 SF
KING STUDIO SUITE - MOBILITY ACCESSIBLE - BATHTUB 2 483 SF 967 SF
KING STUDIO SUITE - MOBILITY ACCESSIBLE - ROLL-IN SHOWER 1 483 SF 483 SF
132 58,360 SF
PUBLIC
CONNECTING CORRIDOR (TYPICAL FLOOR)4 98 SF 393 SF
ELEVATOR 1 1 68 SF 68 SF
ELEVATOR 2 1 64 SF 64 SF
ELEVATOR LOBBY (GROUND FLOOR)1 176 SF 176 SF
ELEVATOR LOBBY (TYPICAL FLOOR)4 157 SF 626 SF
FITNESS (GROUND FLOOR)1 801 SF 801 SF
GUEST CORRIDOR (GROUND FLOOR)1 428 SF 428 SF
GUEST CORRIDOR (TYPICAL FLOOR)4 1,746 SF 6,984 SF
GUEST STORAGE (GROUND FLOOR)1 176 SF 176 SF
LOBBY (GROUND FLOOR)1 2,670 SF 2,670 SF
MEETING ROOM (GROUND FLOOR)1 406 SF 406 SF
MEN'S RESTROOM (GROUND FLOOR)1 171 SF 171 SF
POOL & SPLASH PAD (GROUND FLOOR)1 2,152 SF 2,152 SF
POOL RESTROOM (GROUND FLOOR)1 80 SF 80 SF
PUBLIC CORRIDOR- EAST (GROUND FLOOR)1 162 SF 162 SF
PUBLIC CORRIDOR- WEST (GROUND FLOOR)1 711 SF 711 SF
STAIR 1 5 VARIES 961 SF
STAIR 2 5 VARIES 1,064 SF
VESTIBULE- EAST (GROUND FLOOR)1 28 SF 28 SF
VESTIBULE- LOBBY (GROUND FLOOR)1 150 SF 150 SF
VESTIBULE- WEST (GROUND FLOOR)1 43 SF 43 SF
WOMEN'S RESTROOM (GROUND FLOOR)1 172 SF 172 SF
39 18,488 SF
SITE
COURTYARD 1 3,701 SF 3,701 SF
COURTYARD STORAGE CLOSET 1 46 SF 46 SF
OPEN TRASH ENCLOSURE 1 385 SF 385 SF
OUTDOOR KITCHEN 1 462 SF 462 SF
OUTDOOR STORAGE 1 263 SF 263 SF
PET RELIEF AREA 1 2,116 SF 2,116 SF
PORTE-COCHERE 1 1,722 SF 1,722 SF
7 8,694 SF
NOTE: ALL INTERIOR AREAS ARE CALCULATED TO FACE OF INTERIOR FINISH
THESE PLANS HAVE BEEN DESIGNED IN COMPLIANCE WITH THE 2010 ADA STANDARDS AND ICC 117.1 ACCESSIBILITY REQUIREMENTS FOR ACCESSIBLE DESIGN. THE TERM "ACCESSIBLE" AND ABBREVIATIONS "ADA" OR "ADAAG" WILL BE USED THROUGHOUT THESE PLANS TO REFER TO THE 2010 ADA STANDARDS FOR ACCESSIBLE DESIGN WHICH ARE MANDATED FOR PLACES OF PUBLIC ACCOMMODATION BY TITLE III REGULATIONS OF THE ADA AT 28 CFR PART 36, SUBPART D; AND MUST FOLLOW THE 2004 ADAAG AT 36 CFT PART 1191, APPENDICES B AND D; AND ICC 117.1 ACCESSIBILITY REQUIREMENTS.
THE ARCHITECT OF RECORD CERTIFIES THAT THE CONSTRUCTION DOCUMENTS MEET OR EXCEED THE ADA AND ANY STATE OR LOCAL ACCESSIBILITY CODES THAT ARE MORE STRINGENT. THE CONTRACTOR IS RESPONSIBLE FOR ABIDING BY ALL ACCESSIBILITY REQUIREMENTS ENUMERATED IN THESE DOCUMENTS OR PROVIDED BY THE ARCHITECT DURING CONSTRUCTION. THE OWNER MUST ALSO ENSURE THAT THE FACILITY IS CONSTRUCTED AND MAINTAINED IN COMPLIANCE WITH THE ADA STANDARDS.
THESE PLANS IDENTIFY ACCESSIBLE MINIMUM, MAXIMUM AND DIMENSIONAL RANGES. ADDITIONAL INFORMATION REGARDING THE ADA REQUIREMENTS IS PROVIDED IN THE HILTON ACCESSIBILITY DESIGN GUIDE (HADG) AND THE 2010 AMERICANS WITH DISABILITIES ACT ACCESSIBLITY GUIDELINES. REFERENCES TO THE DIFFERENT CHAPTERS OF THE HADG OR ADAAG ARE INCLUDED WHERE APPROPRIATE.
29.
30.
31.
32.
33.
34.
35.
36.
37.
38.
39.
40.
RESTORE TO THEIR ORIGINAL CONDITION ALL ELEMENTS/ITEMS DAMAGED AS A RESULT OF THE CONSTRUCTION. INCLUDING BUT NOT LIMITED TO: PAVEMENT, EMBANKMENTS, CURBS, SIGNS, LANDSCAPING, STRUCTURES, UTILITIES, WALL FENCES, WALLS, DOORS, GLAZING, TRIMS, FINISHES, ETC, WHETHER IN THE AREA OF WORK OR ELSEWHERE ON THE PREMISES, UNLESS OTHERWISE NOTED. THE COST OF RESTORING DAMAGED IMPROVEMENTS SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR.
THE CONTRACTOR IS TO BE RESPONSIBLE FOR JOB CLEANLINESS. THE OWNER'S FACILITIES SHALL NOT BE USED FOR CONSTRUCTION TRASH/DEBRIS DISPOSAL.
EXAMINE ALL SUBSTRATES TO DETERMINE THAT THEY ARE SOUND, CLEAN AND READY TO RECEIVE FINISHES OR MILLWORK/CASEWORK PRIOR TO INSTALLATION. START OF INSTALLATION OF SAID ITEMS SHALL IMPLY ACCEPTANCE OF THE SUBSTRATE AND SHALL NOT BE GROUNDS FOR CLAIMS AGAINST IMPROPER PERFORMANCE OF INSTALLED MATERIAL. NO CHANGE ORDER WILL BE ISSUED TO RECTIFY UNSATISFACTORY SUBSTRATES ONCE WORK HAS COMMENCED. ADVISE ARCHITECT OF ANY EXISTING CONDITIONS NOT LEVEL, SMOOTH, AND PLUMB, WITHIN INDUSTRY STANDARDS, PRIOR TO START OF ANY CONSTRUCTION.
CONSTRUCTION SHALL BE DONE IN CONFORMANCE WITH THE REQUIREMENTS OF THE 2010 STANDARDS FOR ACCESSIBLE DESIGN ADMINISTERED BY THE DEPARTMENT OF JUSTICE AS PART OF THE ADA. CONSTRUCTION TOLERANCES DO NOT APPLY.
IDENTIFICATION MARKS SHALL BE APPLIED TO ALL INSULATION MATERIALS AND INSULATION INSTALLED SUCH THAT THE MARK IS READILY OBSERVABLE DURING INSPECTION.
WHERE TWO OR MORE LAYERS OF RIGID INSULATION OR GYPSUM WALL BOARD WILL BE USED, ENSURE THAT EDGE JOINTS BETWEEN LAYERS ARE STAGGERED.
PROVIDE WALL BOARD TRIM AT ALL EXPOSED EDGES AND CORNERS OF GYPSUM WALLBOARD CONSTRUCTION. J-BEAD OR OTHER NON-DRYWALL COMPOUND TRIM PIECES PROHIBITED (U.N.O.)
CONTRACTOR SHALT ENSURE THAT ANY AND ALL BACK BOXES LOCATED BETWEEN LIVING OR BEDROOMS ARE NOT LOCATED BACK TO BACK OR IN THE SAME CAVITY. STAGGER BOXES ONE STUD CAVITY EITHER SIDE OF ONE ANOTHER.
COORDINATE, PROVIDE, AND INSTALL 2X TREATED WOOD WALL BLOCKING OR 25 GA METAL STRAPPING AS REQUIRED FOR THE ANCHORAGE AND SUPPORT OF ALL NEW CASEWORK, TRIM, TOILET ACCESSORIES, DOOR HARDWARE ACCESSORIES, DESIGNATED ART WORK WALLS, ETC., AS APPLICABLE.
ALL FLOOR AREAS THAT REQUIRE LEVELING WITH A CONCRETE TOPPING OR LEVELING COMPOUND SHALL BE INSTALLED SUCH THAT THE FLATNESS EQUALS 35/24 (ON ALL SLABS) AND THE LEVELNESS EQUALS 'SLAB ON GRADE) AND 80% OF THAT VALUE ON ELEVATED SLABS.
THE CONTRACTOR IS TO PROVIDE A COMPLETE, FINISHED, AND FUNCTIONAL INSTALLATION OF ALL COMPONENTS DESCRIBED IN THESE DRAWINGS.
PROJECT CLOSEOUT DOCUMENTATION IS REQUIRED INCLUDING APPLICABLE WSEC ENVELOPE COMPLIACE FORMS AND CALCULAIONS, AND FENESTRATION NFRC RATING CERTIFICATES.
ACCESSIBILITY NOTES
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
Revision Schedule
Number Description Date
GENERAL
The General Contractor shall verify all dimensions and site conditions before starting work. The Architect and
Structural Engineer shall be notified of any discrepancy. Use details marked "Typical" wherever applicable.
Changes, omissions or substitutions are not permitted without written approval of the Architect and Structural
Engineer. Refer to specifications for further requirements. In the case of conflicts between plans and
specifications, the more restrictive requirements shall apply. Any discrepancies on the Contract Documents
should be brought to the attention of the Architect and Structural Engineer prior to proceeding with the work.
All materials and workmanship shall conform to the 2018 edition of the International Building Code (IBC) and
the 2016 edition of “Minimum Design Loads for Buildings and Other Structures” by the American Society of
Civil Engineers. Use the latest edition of Referenced Standards as noted in Chapter 35 of the IBC.
The Contract structural drawings represent the finished structure. The Contractor is responsible for the
means, methods and sequence of construction. The design, adequacy and safety of erection bracing,
shoring, temporary supports, etc., is the sole responsibility of the Contractor, and has not been considered by
the Structural Engineer. The Contractor is responsible for the stability of the structure prior to the completion
of all shear walls, roof and floor diaphragms and finish materials. The Contractor shall provide the necessary
bracing to provide stability to the structure prior to the installation of the permanent lateral force resisting
system. Observation visits to the site by the Structural Engineer shall not include inspection of temporary
bracing, shoring, etc.
The Contractor shall coordinate the size and locations of all openings in roofs, floors and walls. Openings
shall not penetrate any structural elements such as beams, columns, walls, slabs, etc. unless noted on the
drawings or approved by the Structural Engineer.
DEFERRED SUBMITTALS
Items designed by a Specialty Structural Engineer shall be submitted to the Architect and Structural Engineer
for review and shall bear the seal and signature of an engineer registered in the state of Washington.
Submittals shall include calculations, design drawings, product data and shop drawings. Design shall be
based on information provided on the drawings for gravity, wind and seismic forces unless noted otherwise.
The Contractor shall coordinate the seismic restraint of mechanical, plumbing and electrical equipment and
the associated piping to the structure. Connections to the structure shall conform to SMACNA standards, be
detailed on the contract drawings or be designed by an engineer registered in the state of Washington and
submitted for Architect and Structural Engineer review prior to fabrication.
SHOP DRAWINGS
Shop drawings are to be checked and approved by the General Contractor prior to submitting for Architect and
Structural Engineer review. General Contractor is responsible for verification and coordination of dimensions
and details for each Subcontractor. Quantities and dimensions are not reviewed by the Structural Engineer
and therefore must be verified by the General Contractor. No fabrication shall proceed until shop drawings
have been approved. Review of the Specialty Structural Engineer’s design submittals and shop drawings is
for general compliance with design criteria and compatibility with the design of the primary structure and does
not relieve the Specialty Structural Engineer of responsibility for that design.
DESIGN LOADS
Building Risk Category -------------------------------- II
Snow Loading
Ground Snow Load, Pg ---------------------- 39 PSF
Flat Roof Snow Load, Pf -------------------- 27 PSF
Minimum Uniform Snow --------------------- 30 PSF
Snow Exposure Factor, Ce ----------------- 1.0
Thermal factor, Ct ---------------------------- 1.0
Snow Load Importance Factor, Is --------- 1.0
Roof Design Load Cases:
1) Pf + Drifting/Sliding/Unbalanced
2) Minimum Uniform Snow
Floor Loading
Floor Live Load (Private Rooms) ---------- 40 PSF
Floor Live Load (Public Rooms) ---------- 100 PSF
Corridor Live Load --------------------------- 100 PSF (Serving Public Rooms)
Stair Live load --------------------------------- 100 PSF (300# Concentrated Live Load)
Linen Storage Live Load -------------------- 125 PSF
Mechanical Room Live Load -------------- *** PSF
See plans for special mechanical unit loading.
Wind Loading
Basic Wind Speed(3-second gust) ------- 110 MPH
Wind Exposure -------------------------------- C
Wind Importance Factor, IW---------------- 1.0
Enclosure Classification -------------------- Enclosed
Seismic Loading - Equivalent Lateral Force Procedure
Seismic Importance Factor, IE ------------- 1.0
Spectral Response Accelerations SS = 0.314 S1 = 0.112
Site Class --------------------------------------- D
Seismic Design Category ------------------- C
Site Coefficient Fa ---------------------------- 1.549
Site Coefficient Fv ---------------------------- 2.376
Spectral Response Coefficients ---------- SDS = 0.324 SD1 = 0.177
Basic Seismic Force-Resisting Systems:
Light frame wood walls with structural wood panels
Special Moment Frame
Response Modification Factor, R ---------6.5
Overstrength Factor, Ω0 -------------------- 3
Deflection Amplification Factor Cd ------- 5.5
Seismic Response Coefficient, CS ------- 0.05 LRFD
Solar Readiness
All roof areas shall be designed for an additional dead load of 4 PSF to accommodate future
photovoltaic system arrays.
FOUNDATION
Based on the geotechnical engineering report #221-306G by Allwest, dated January 28, 2022, design
allowable soil bearing pressure = 3000 PSF. Bottom of all footings to bear on native, inorganic, undisturbed
soil 1'-0" minimum below existing grade. Extend all exterior footings 2'-0" minimum below finished grade to
protect against frost action. No footing shall bear higher than a 1 vertical to 1.5 horizontal slope above any
excavation, existing or planned. Contractor shall provide temporary shoring to prevent movement of walls if
backfill is placed before floor system is in place. Site preparation, grading, backfilling, etc. shall be as
recommended by the geotechnical report. There shall be 95% compaction (ASTM D1557 Modified Proctor
Density) of all backfill soil under slabs on grade.
Per the geotechnical report, retaining and basement walls have been designed with the following (assumed)
parameters:
Equivalent Fluid Pressure:
Active Condition --------------------------------------- 50 PCF
At-rest/restrained Condition ------------------------ 70 PCF
Passive Condition ------------------------------------- 285 PCF
Soil/Concrete Friction ------------------------------------------ 0.40
CAST-IN-PLACE CONCRETE
Concrete mix proportions in accordance with ACI 301 to meet or exceed the requirements as listed below:
Minimum 28 Day Maximum Maximum Maximum
Compressive Air Size Water/Cement
Strength Entrainment Aggregate Ratio
All structural conc, UNO 3000 PSI None 3/4”
Footings 3000 PSI None 1-1/2"
Foundation stem walls 3000 PSI 5% 3/4"
Exterior C.I.P. walls 3000 PSI 5% 3/4"
Topping slabs 3000 PSI None 3/8"
Balcony Slab over metal deck 3500 PSI 5% 3/4”
Interior slab on grade 4000 PSI None 3/4" .50(*)
Polished slab on grade 4000 PSI None 1-1/2" .50
Exterior slab on grade 4500 PSI 6% 3/4" .45
Maximum Slump: Comply with typical slump ranges specified in the latest edition of ACI 211.1. Larger
slumps may be allowed through the use of a super plasticizer.
Construction to be in accordance with the latest edition of ACI 318, "Part 6 - Materials and Durability", "Part
8: Reinforcement", and "Part 9: Construction".
Location of construction or pour joints for walls, beams, columns, and structural slabs must be approved by
the Structural Engineer if different from that shown on plans.
(*) Use a maximum water/cement ratio of 0.45 for interior slabs on grade that could be subject to freeze/thaw
cycling while saturated during the construction period.
CONCRETE SLABS ON GRADE
The General Contractor shall control and monitor construction procedures and conditions as required to
provide a high quality finished slab with minimal cracks, curling, and surface defects. Procedures and
conditions under the control of the General Contractor include, but are not limited to: provisions for ambient
weather conditions, curing methods selected, rate of placement, joint arrangement and installation,
temperature control, subgrade preparation, and reinforcing placement (where indicated).
Placement on Vapor Barrier: Slabs poured directly on vapor barrier are intended to facilitate vapor-
emission rates frequently required for floor covering installation. Concrete cure time may be longer than for
slabs not in direct contact with vapor barrier; General Contractor to coordinate curing and floor covering
installation requirements as required.
Slab Finishes: Concrete slabs on grade shall be provided with finish techniques in accordance with the
floor classification table of ACI 302.1R. Intended use for interior slabs shall be categorized as either Class 2,
Class 4, or Class 5, unless noted otherwise.
Slab Joints: Except where specifically indicated, joint spacing and arrangement is to be determined by the
General Contractor as part of slab installation procedure. A proposed joint layout plan shall be submitted for
architect and engineer approval prior to slab pour. In general, apply the following parameters:
Maximum joint spacing, subject to factors above:
Typical, UNO: 36 times slab thickness
Exposed & Polished slabs: 24 times slab thickness
Maximum aspect ratio between joints: 1.5 to 1
Avoid re-entrant corners
POLISHED CONCRETE SLABS ON GRADE
The General Contractor shall comply with all provisions noted above, plus additional requirements listed
here. Crack control and minimization is imperative at all polished slab areas.
Concrete Mix: Fly ash, water vapor reducing admixtures, and air entraining admixtures are not to be
included in the mix design. Fiber reinforcement shall not be provided in polished slabs. Maximum cement
content shall be 517# per cubic yard (5.5 sack mix). Mix design shall provide for maximum curing shrinkage
of 0.0003" per inch.
Slab Joints: A proposed joint-layout plan shall be submitted for architect and engineer approval prior to
slab pour. Reference the architectural drawings for preferred joint locations, and follow joint parameters
noted above for standard slabs on grade.
FIBER REINFORCEMENT
Where fiber reinforcement is specified on the plans for concrete slabs on grade, provide synthetic
macrofibers made of 100% virgin copolymer/polypropylene complying with ASTM C 1116, Type III, minimum
2" fiber length, aspect ratio of 50 to 90, at a dosage rate of 4.0 LBS/CY, unless noted otherwise. Follow
manufacturer's recommendations for proper batching and mixing procedures.
MASONRY
Design Compressive Strength:CMU masonry f'm = 2000 PSI at 28 days.
Concrete Masonry Units: ASTM C90-14, medium weight(115 pcf), running bond.
Minimum compressive strength = 2000 PSI.
Mortar: ASTM C270, Type S, with a minimum compressive strength of 1800 PSI at 28 days.
Grout: ASTM C476 with a minimum compressive strength of 2000 PSI at 28 days with a maximum
aggregate size of 3/8”.
Fill all cells containing reinforcing with grout in lifts not exceeding 5'-4" in height. Stop each grout lift 1 ½”
below the top course in the lift except at the top of the wall. Fill other cells with grout as indicated on
drawings. Unless noted otherwise, lap all bar splices 48 diameters minimum. All reinforcement shall be in
place prior to grouting with vertical bars held at top, bottom and 192 diameters maximum on center.
Contractor shall provide temporary bracing for masonry walls, as required, until connections to floor and/or
roof diaphragms are completed.
REINFORCING STEEL
Welded Wire Fabric: ASTM A1064, Fy = 65 KSI supplied in flat sheets and lapped a minimum of 12” on all
sides.
Deformed Bars: ASTM A615, Grade 60.
Weldable Deformed Bars: ASTM A706, Grade 60 for #4 and larger.
Securely tie in place with double annealed 16 gauge iron wire or approved clips. Provide chairs, bolsters,
etc. to place reinforcement in the proper positions as indicated on the drawings. Unless otherwise noted on
these drawings, provide clear embedment at reinforcing bars as follows:
Concrete cast against soil = 3".
Formed concrete against soil = 2".
Walls, columns and beams exposed to weather = 2".
Walls, columns and beams not exposed to weather = 1 1/2".
Slab on grade = 2".
Detailing of concrete reinforcement bars and accessories shall conform to the recommendations of ACI 315
“Details and Detailing of Concrete Reinforcement” and ACI SP-66 “Detailing Manual”. Placing of
reinforcement shall conform to ACI 315R “Manual of Engineering and Placing Drawings for Reinforced
Concrete Structures” and CRSI “Manual of Standard Practice”. Reinforcement bars shall not be tack welded,
heated, or cut unless specifically detailed on the drawings or as approved by the Structural Engineer. The
welding of reinforcing steel, metal inserts and connections in reinforced concrete shall conform to AWS D1.4
“Structural Welding Code – Reinforcing Steel” by AWS/WABO certified welders using E9018 or approved
electrodes. Submit mill test report of material properties to determine carbon equivalent and minimum
preheat temperatures. ASTM A706 reinforcement may be substituted for A615 reinforcement.
Submit shop drawings of reinforcing steel for review by the Structural Engineer prior to fabrication. All wall
reinforcement shop drawings shall be shown in elevation.
STRUCTURAL AND MISCELLANEOUS STEEL
C & L Shapes, plates and bars: ASTM A36, Fy = 36 KSI
HP Shapes: ASTM A572, Fy = 50 KSI
Wide Flange & WT Shapes: ASTM A992, Fy = 50 KSI
Pipe: ASTM A53, Grade B, Type E or S, Fy = 35 KSI minimum.
Square & Rectangular HSS: ASTM A500, Grade C, Fy = 50 KSI
Round HSS: ASTM A500, Grade C, Fy = 50 KSI
Bolts: ASTM A307 machine bolts (MB).
High Strength Bolts: ASTM A325 high strength bolts (HSB),Type 1 with ASTM F436 hardened steel
washers and ASTM A563 heavy hex nuts.
High strength bolts shall be installed to a "snug tight" condition where all plies of the joint are in firm contact
for typical beam end connections, column cap plate connections, etc. unless noted otherwise.
Where noted as “slip-critical” (SC), high strength bolts shall be installed with load indicator devices (ASTM
F959 load indicator washers or ASTM F1852 snap-off heads). Provide a Class A faying surface on
connected elements.
Anchor Rods(AR):Headed or threaded rod with heavy hex nut, ASTM F1554, Fy = 36 KSI with A563C
(A563DH for galvanized) heavy hex nuts and F436-1 washers. (F1554 is also available in 55 KSI and 105
KSI)
Anchor Bolts(AB):Headed A307, Grade A or hooked ASTM A36.
Threaded rod:ASTM A36, Fy = 36 KSI.
Headed anchor stud (HAS): ASTM A108 Type A, Fy = 49 KSI for general use and Type B, Fy = 51 KSI for
composite steel-concrete construction. Headed anchor studs shall be end welded per manufacturer's
recommendations.
Deformed bar anchors (DBA): ASTM A1064, Fy = 70 KSI, end welded per manufacturer's
recommendations.
Threaded Anchor Stud (TAS): ASTM A108, Fy = 49 KSI, end welded per manufacturer's
recommendations.
Welding electrodes or wires: AWS A5.1 or A5.5, E70XX; AWS A5.18, E70S-X; AWS A5.20, E7XT-X.
Non-shrink Grout: "Masterflow 928" as manufactured by BASF Building Systems or approved equal with a
minimum compressive strength of 5000 PSI.
Erection and fabrication in accordance with AISC 360 “Specification for Structural Steel Buildings”, AISC 341
“Seismic Provisions for Structural Steel Buildings”, and AISC 303 “Code of Standard Practice for Steel
Buildings and Bridges”. Welding shall conform to AWS D1.1 "Standard Welding Code - Steel". All welding
shall be performed by AWS/WABO Certified Welders whose certification meets "AWS Standards" in an
approved fabricator shop or where Special Inspection is provided. All columns and beams to be from
unspliced lengths unless noted otherwise on the drawings. All members to have "Standard" size holes
unless noted as short-slotted (SSL) or long-slotted (LSL). Enlargement of holes by burning is not permitted.
Submit shop drawings showing sizes, dimensions and required connection details for review by the Architect
and Structural Engineer prior to fabrication.
STEEL DECK
Provide steel deck of depth and gage indicated on the structural drawings in conformance with ASTM A653
or A1063, Grade 50 Structural Quality with G60 zinc coating (G90 at exterior balconies). Conform with
ASTM A653 SS, Grade 80 for shallow and deep Vercor form deck. Individual sheet length shall be
continuous for 3 or more spans. Provide flashing and closures at all locations as required for the deck to
receive concrete. All deck welding shall be in accordance with AWS D1.3 “Structural Welding Code – Sheet
Steel”. No hangers for piping, ductwork, etc. shall be directly attached to steel roof deck. Submit shop
drawings showing layout for review by the Architect and Structural Engineer.
LIGHTGAGE STRUCTURAL STEEL STUDS AND JOISTS
Studs and track, 18(43 mils) & 20(33 mils) gage bridging, and accessories:Fy = 33 KSI conforming to
ASTM A653 SS (Galvanized).
Studs and track, 14(68 mils) & 16(54 mils) gage: Fy = 50 KSI conforming to ASTM A653 SS Class 1 or 3
(Galvanized).
Unpunched joists, 18 gage(43 mils): Fy = 33 KSI conforming to ASTM A653 SS (Galvanized).
Unpunched joists, 12(97 mils), 14(68 mils), and 16(54 mils) gage:
Fy = 50 KSI conforming to ASTM A653 SS Class 1 or 3.
All structural properties computed in accordance with latest edition of AISI S100 "North American
Specification for the Design of Cold Formed Steel Structural Members". Designations on the drawings are
Steel Stud Manufacturer's Association. Approved equivalent products may be permitted upon written
approval of the Architect and Structural Engineer. Install members in accordance with industry standards.
Unless otherwise noted on these drawings, stud wall track to be of the same material and gage as studs.
Provide horizontal bridging at 5'-0" o.c. maximum at non-bearing walls and 3'-4" o.c. maximum at bearing
walls. Bearing walls to be erected with stud ends seated against track web top and bottom with a maximum
of 1/16” clearance. Submit shop drawings showing stud and joist layout, dimensions, sizes, bridging and
required connection details for review by the Architect and Structural Engineer. All welding to be performed
by AWS/WABO Certified Welders in accordance with AWS D1.3 “Structural Welding Code – Sheet Steel”.
WOOD
Sawn Lumber:Douglas Fir-Larch S-Dry 19% MC, WWPA 2017 Western Lumber grading rules furnished to
the following minimum standards:
Studs 2x4 Standard or better
2x6 #2 or better
Joist & Rafters 2x, 3x, 4x widths
6" to 14" deep #2 or better
Top & Sill Plates 2x width #2 or Construction Grade
Beams & Stringers 6x widths & larger #1 or better
Posts and Timbers 6x widths & larger #1 or better
T&G Decking 2x, 3x, 4x widths Selected Grade
Treated Framing 2x, 3x, 4x widths Hem-Fir #2 or better
FRT Studs/Plates/hdrs 2x, 3x, 4x widths
All wood bearing on concrete or masonry, if less than 4'-0" above grade, shall be preservative treated.
Structural members shall not be cut for pipes, ducts, etc., unless specifically noted or detailed.
Glued-Laminated Timbers: All members shall conform to the latest edition of AITC 117
"Design Standard Specifications for Structural Glued-Laminated Timber of Softwood Species".
Simple-span beams: Stress Class 24F-1.8E Combination Symbol 24F-V4
Continuous beams: Stress Class 24F-1.8E Combination Symbol 24F-V8
Cantilever beams: Stress Class 24F-1.8E Combination Symbol 24F-V8
Compression members: Combination Symbol 2
Tension members: Combination Symbol 3
Camber all simple-span beams to a radius of 5000 feet, unless noted otherwise on the plans. Shop
Drawings of glu-laminated members shall be submitted for review by the Structural Engineer prior to
fabrication.
Roof Sheathing: 5/8” (19/32” minimum) APA rated sheathing, Exposure 1, PRP-108, ESR-2586, Span
Rating 40/20. Provide tongue & groove edges, ply clips, or blocking at all panel edges where roof slopes are
less than 2:12, or spacing of support framing exceeds 32” oc, or where noted on the drawings. Lay
sheathing with face grain perpendicular to supports continuous over 2 or more spans with end joints
staggered. Allow 1/8" spacing at panel ends and edges. Attach to framing with 8d @ 6” oc at panel edges
and 12” oc at intermediate supports unless noted otherwise.
Floor Sheathing: 3/4” (23/32” minimum) APA rated sheathing, Exposure 1, PRP-108, ESR-2586, Span
Rating 48/24, with tongue & groove edges. Lay sheathing with face grain perpendicular to supports
continuous over 2 or more spans with end joints staggered. Allow 1/8" spacing at panel ends and edges.
Sheathing shall be field-glued to support framing using adhesives meeting APA Specification AFG-01
applied per manufacturer's recommendations. Tongue and groove edges shall also be field-glued. Attach to
framing with 8d @ 6” oc at panel edges and 12” oc at intermediate supports unless noted otherwise.
Wall Sheathing: 1/2” (15/32” minimum) APA rated sheathing, Exposure 1, PRP-108, ESR-2586, Span
Rating of 24/0. Provide solid blocking at all panel edges. Lay sheathing with face grain perpendicular to
supports continuous over 2 or more spans. Allow 1/8" spacing at panel ends and edges. Attach to framing
with 8d @ 6” oc at panel edges and 12” oc at intermediate supports unless noted otherwise.
Framing anchors and connectors: "Simpson" or approved equal as indicated on drawings. Install per
manufacturer's recommendations. Bolt heads and nuts in contact with wood shall have washers. For nailing
not shown on drawings, use IBC Fastening Schedule, Table 2304.10.1. Nails shall not be overdriven.
Preservative-Treated Wood:LSB Staff: See Office Design Std D-08
All preservative-treated wood (PT) and fire-treated wood (FT) shall be treated in compliance with the
American Wood Protection Association (AWPA) standard U1-09. The AWPA Use Category System (UCS)
shall be used to determine an appropriate AWPA-approved preservative system and retention level for
specific commodities and end-uses. Unless otherwise specified, species and retention levels used in the
preservative system shall be compliant with those listed in Section 6 of AWPA-U1-09. Treatments CCA-C,
ACQ-A, and ACQ-B are prohibited. All framing hardware, connectors, etc. in contact with treated wood shall
be galvanized per ASTM A653 or stainless steel. All framing hardware fasteners into treated wood shall be
galvanized per ASTM A153 or stainless steel.
METAL PLATE CONNECTED WOOD TRUSSES
Maximum truss spacing: 24" o.c.
Truss loading unless noted otherwise on drawings:
Top chord live load = See "DESIGN LOADS"
Top chord dead load = 8 PSF + Solar Readiness
Bottom chord live load = 10 PSF (Not capable of storage)
Bottom chord dead load = 8 PSF
Design trusses for wind uplift for components and cladding per ASCE 7-10, Section 30.4 (enclosed).
Verify weight and locations of all mechanical equipment to be supported by trusses prior to fabrication.
Camber trusses for dead load deflection. Live load deflection should not exceed L/360.
Trusses to be fabricated by a certified member of the Structural Building Components Association (SBCA)
meeting the requirements of an “Approved Fabricator” per IBC 1704.2.5.1 or where “Special Inspection” at
the fabrication site is provided.
Design and fabrication to conform to the Truss Plate Institute Standard ANSI/TPI 1-2007. Connector plates
shall be ICC approved. Connector plates shall be sized for 150% (175% for scissor trusses) of member
forces with a minimum size of 3"x5". Truss designs and shop drawings shall be stamped by a professional
engineer registered in the State of Washington. Shop drawings shall include, for each type of truss,
dimensions and configurations, nominal lumber size and grade, specifications for connector plates used,
size and location of each connector at each joint and amount of camber if required. Shop drawings shall
include erection plans showing truss spacing, truss mark numbers (corresponding to the design
calculations), concentrated loads, and permanent bracing/bridging as required by the truss design.
Erection bracing shall comply with Truss Plate Institute “Building Component Safety Information, BCSI
2006: Guide to Good Practice for Handling, Installing, Restraining & Bracing of Metal Connected Wood
Trusses". Design calculations and shop drawings shall be submitted for review by the Architect and
Structural Engineer prior to fabrication.
PROPRIETARY WOOD PRODUCTS
Floor Dead Load = 25 PSF
Floor Live Load = See "DESIGN LOADS"
TimberStrand LSL 1.55E Fb = 2325 PSI by TrusJoist Weyerhauser
TimberStrand 1 ¼” Rimboard 1.3E Fb = 1700 PSI by TrusJoist Weyerhauser
Microlam LVL 2.0E Fb = 2600 PSI by TrusJoist Weyerhauser
Parallam PSL 2.0E Fb = 2900 PSI by TrusJoist Weyerhauser
Redlam LVL 2.0E Fb = 2900 PSI by RedBuilt
Premanufactured wood I-joists, beams, and trusses to have ICC acceptance, and be of the same depths
and spacing as noted on the framing plans. Member designations shown on the drawings correspond to
TrusJoist Weyerhauser or RedBuilt products; products from other manufacturers may be substituted if they
have equivalent load carrying capacities and meet the depth, spacing and fire resistance requirements
shown on the drawings. Product substitution shall be approved by the Structural Engineer prior to bid date.
Install the product per manufacturer's recommendations. Submit shop drawings of layout and required
connection details for review by the Architect and Structural Engineer prior to fabrication.
POST-INSTALLED ANCHORS
All post-installed anchors shall have current ICC ESR Reports indicating code-approved installation
requirements. Contractor shall comply with all requirements of the ESR report. Substitution of post-
installed anchors for anchor bolts, anchor rods, or rebar dowels is not allowed without written approval of
the Structural Engineer. Special Inspection is required for all post-installed anchors. Special Inspection for
Contractor-requested substitutions (if approved) shall be provided at no additional cost to the Owner.
Adhesive Anchors (AA) in Concrete: ASTM A307, Grade C threaded rod with Simpson SET-3G
adhesive or Hilti “HAS-E” threaded rod or Grade C threaded rod with HIT-HY 200 adhesive or approved
equal. Concrete to have aged a minimum of 21 days prior to installation.
Adhesive Dowels (AD) in Concrete: ASTM A615 deformed bar with Simpson SET-3G adhesive or Hilti
HIT-HY-200 adhesive or approved equal. Concrete to have aged a minimum of 21 days prior to
installation.
Powder Actuated Fasteners(PAF)into Steel: Hilti X-U 15(.145” dia) fasteners into steel of a minimum
3/16” thickness.
QUALITY ASSURANCE and SPECIAL INSPECTIONS
A qualified special inspector(s) shall be engaged by the Owner or Owner’s representative to conduct
continuous and periodic inspections as tabulated on sheet S003. Construction activity shall be coordinated
with required inspections and testing requirements by the Contractor. Construction deficiencies identified
by the special inspection process shall be remedied by the Contractor at no cost to the Owner.
737 BISHOP STREET, SUITE 1860
HONOLULU, HI 96813
808-352-5299
OWNER:
523 EAST THIRD AVENUE
SPOKANE, WA 99202
P 509.323.9292
F 509.747.7115
HOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 99216GENERAL STRUCTURAL
NOTES
S001
FSC PROJECT NO. 21012
PERMIT SET
5/31/2024
GL8 Mirabeau
Point, LLC
10909 E. Pierce Lane
Spokane, WA 99206
(509) 919-0901
GENERAL STRUCTURAL NOTES
Revision Schedule
Number Description Date
J.B.
T.O.W.
T.O.P.
T.O.B.
T.O.S.
T.O.C.
T.O.F.
T.O.M.
FIN SLAB
-SS-
-
-
-
-
-
-
LEGEND
CMU WALL
TOP OF CONCRETE ELEVATION
TOP OF FOOTING ELEVATION
TOP OF SLAB ELEVATION
TOP OF PARAPET ELEVATION
TOP OF BEAM ELEVATION
TOP OF WALL ELEVATION
ELEVATION CHANGE
STEPPED FOOTING
BM SIZE
(114'-2") (C=¼")
W16x31 [10]
FOOTING MARK
METAL STUD WALL
HOLDOWN MARK
TOP OF BM ELEVATION
BEAM DESIGNATION
ROOF TOP MOUNTED MECH
UNIT WEIGHT AS NOTED
SLAB JOINT
FINISH FLOOR ELEVATION
SHEAR WALL MARK
DETAIL
MECH UNIT MOUNTED UNDER
AND FROM FRAMING W/WEIGHT
SECTION NUMBER
SHEET NUMBER
ELEVATION
ELEVATION LETTER
DETAIL NUMBER
SHEET NUMBER
SHEET NUMBER
BUILDING SECTION
WOOD STUD WALL
CAMBER
SHEAR STUDS, SEE TYPICAL DETAILS
REVISION MARK
CONTROL JOINT
JOIST BEARING ELEVATION
F3
1
1
C JS J2558.56'
800#
800#
CONTINUOUS FOOTING MARKCF3
TOP OF MASONRY ELEVATION
FINISHED SLAB ELEVATION
MATCHLINE
THICKENED SLAB FOOTING MARKTS3
STEM WALL MARKSW8
1. THE CONTINUOUS ROD TIEDOWN SYSTEM FOR THIS PROJECT SHALL BE THE SIMPSON STRONG-TIE STRONG-ROD ANCHOR TIEDOWN SYSTEM (ATS)
FOR SHEARWALL OVERTURNING RESTRAINT.
2. SIMPSON STRONG-TIE SHALL PROVIDE THE ATS TO MEET THE DESIGN FORCES, TOTAL VERTICAL DISPLACEMENT LIMIT, AND SHRINKAGE
REQUIREMENTS AS SET FORTH IN THE STRUCTURAL DRAWINGS. ATS CALCULATIONS AND INSTALLATION DETAILS SHALL BE PROVIDED TO THE
DESIGNER OR ENGINEER OF RECORD FOR REVIEW AND APPROVAL.
3. ALLOWABLE ROD CAPACITIES SHALL BE CALCULATED PER AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC) SPECIFICATION FOR STRUCTURAL
STEEL BUILDINGS.
a. AISC 360 - 16 FOR 2018 INTERNATIONAL BUILDING CODE
4. BEARING PLATE, WOOD STUD AND FASTENER CAPACITIES SHALL BE CALCULATED PER THE NATIONAL DESIGN SPECIFICATION (NDS) FOR WOOD
CONSTRUCTION.
a. NDS - 18 FOR 2018 INTERNATIONAL BUILDING CODE
5. SHRINKAGE COMPENSATING DEVICES SHALL BE PROVIDED AT EACH RESTRAINT LOCATION AND ACCOUNT FOR THE SHRINKAGE AMOUNT AT EACH
STORY AS SET FORTH ON THE STRUCTURAL DRAWINGS.
6. THE TOTAL VERTICAL DISPLACEMENT BETWEEN RESTRAINT LOCATIONS, INCLUDING STEEL ROD ELONGATION AND SHRINKAGE COMPENSATING
DEVICE DEFLECTION, SHALL BE LESS THAN 0.20 INCHES OR AS SET FORTH IN THE STRUCTURAL DRAWINGS, USING ALLOWABLE STRESS DESIGN (ASD).
STEEL ROD ELONGATION SHALL BE COMPUTED AS THE PRODUCT PL/AE, WHERE P IS THE AXIAL LOAD (LB.), L IS THE INITIAL ROD LENGTH BETWEEN
RESTRAINT LOCATIONS AT THE STORY UNDER CONSIDERATION (INCHES), E IS 29,000,000 (PSI) AND A IS THE NET TENSILE AREA OF THE ROD
(IN.2). SHRINKAGE COMPENSATING DEVICE DEFLECTION SHALL BE AS SPECIFIED IN ICC-ES ESR-2320 INCLUDING R + A (PD/PA).
7. THE ATS SHALL BE RESTRAINED BY A BEARING PLATE AND TAKE-UP DEVICE ASSEMBLY AT EACH STORY OF THE MULTI-STORY SHEARWALLS. NOTE:
SKIPPING STORIES, WHERE BEARING PLATES ARE OMITTED AT INTERMEDIATE FLOORS THAT RESULT IN MULTIPLE STORIES BEING TIED
TOGETHER, IS PROHIBITED.
8. DO NOT WELD PRODUCTS UNLESS THE ATS INSTALLATION DETAILS SPECIFICALLY IDENTIFY A PRODUCT AS ACCEPTABLE FOR WELDING. SOME
STEELS HAVE POOR WELDABILITY AND A TENDENCY TO CRACK WHEN WELDED. RODS, NUTS, AND COUPLER NUTS SHALL NOT BE WELDED.
9. IN THE EVENT OF A DISCREPANCY BETWEEN THE STRUCTURAL DRAWINGS AND THE ATS INSTALLATION DETAILS, THE STRUCTURAL DRAWINGS SHALL
GOVERN.
10. THE STRUCTURAL DRAWINGS ARE SPECIFIC TO THE SIMPSON STRONG-TIE STRONG-ROD ANCHOR TIEDOWN SYSTEM (ATS) AND ARE NOT APPLICABLE
TO OTHER MANUFACTURERS’ CONTINUOUS ROD TIEDOWN SYSTEMS. PROPOSED SUBSTITUTIONS OF OTHER MANUFACTURERS’ CONTINUOUS ROD
TIEDOWN SYSTEMS SHALL BE SUBMITTED TO THE DESIGNER OR ENGINEER OF RECORD FOR REVIEW AND APPROVAL AT THE CONTRACTOR’S
EXPENSE. SUBMITTAL SHALL INCLUDE EVALUATION REPORTS INDICATING COMPLIANCE WITH GOVERNING BUILDING CODES AND TEST DATA
PERFORMED IN ACCORDANCE WITH ICC-ES ACCEPTANCE CRITERIA FOR SHRINKAGE COMPENSATING DEVICES (AC316). IN ADDITION, SUBMITTAL
SHALL INCLUDE INSTALLATION DETAILS AND INSTRUCTIONS, CALCULATIONS IN ACCORDANCE WITH THE GOVERNING BUILDING CODES, AND
CERTIFICATION BY THE MANUFACTURER OF COMPLIANCE WITH THESE ATS SPECIFICATIONS AND THE STRUCTURAL DRAWINGS.
11. ATS RUN START/TERMINATIONS SHALL BE AS SET FORTH ON THE STRUCTURAL DRAWINGS. ALTERNATE RUN START/TERMINATIONS SHALL BE
SUBMITTED TO THE DESIGNER OR ENGINEER OF RECORD FOR REVIEW AND APPROVAL PRIOR TO PLACEMENT OF THE CONCRETE AND AT THE
CONTRACTOR’S EXPENSE. SUBMITTAL SHALL INCLUDE CALCULATIONS IN COMPLIANCE WITH THE GOVERNING BUILDING CODE, INCLUDING CONCRETE
ANCHORAGE IN ACCORDANCE WITH ACI 318 PROVISIONS FOR STRENGTH DESIGN AND CONVERSION TO ASD LOAD LEVELS.
12. THE ATS IS DESIGNED TO BE INSTALLED FLOOR BY FLOOR AS THE STRUCTURE IS BUILT. INSTALLATION IN THIS MANNER, WITH SHEARWALLS, WILL
PROVIDE A LATERAL-FORCE-RESISTING SYSTEM DURING CONSTRUCTION. THE DESIGN AND EXPENSE OF ALTERNATIVE METHODS OF TEMPORARY
LATERAL-FORCE-RESISTING SYSTEMS ARE THE RESPONSIBILITY OF THE CONTRACTOR.
13. A PRE-CONSTRUCTION MEETING IS RECOMMENDED WITH SIMPSON STRONG-TIE PRIOR TO PLACEMENT OF THE CONCRETE. THE PURPOSE OF THIS
MEETING IS TO ASSIST IN VERIFYING QUANTITIES AND UNDERSTANDING THE INSTALLATION PROCESS. TO COORDINATE THIS MEETING, CALL
SIMPSON STRONG-TIE AT (800) 999-5099.
GENERAL NOTES FOR SIMPSON STRONG-TIE® STRONG-ROD ANCHOR TIEDOWN SYSTEM
737 BISHOP STREET, SUITE 1860
HONOLULU, HI 96813
808-352-5299
OWNER:
523 EAST THIRD AVENUE
SPOKANE, WA 99202
P 509.323.9292
F 509.747.7115
HOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 99216ABBREVIATIONS &
LEGEND
S002
FSC PROJECT NO. 21012
PERMIT SET
5/31/2024
GL8 Mirabeau
Point, LLC
10909 E. Pierce Lane
Spokane, WA 99206
(509) 919-0901
AA ADHESIVE ANCHOR
AB ANCHOR BOLT
AD ADHESIVE DOWEL
ADD'L ADDITIONAL
AFF ABOVE FINISH FLOOR
ALT ALTERNATE
& AND
APPROX APPROXIMATE
AR ANCHOR ROD
ARCH ARCHITECT
ARCHL ARCHITECTURAL
@ AT
B.O. BOTTOM OF
BOT BOTTOM
BLDG BUILDING
BLKG BLOCKING
BM BEAM
BRG BEARING
BSMT BASEMENT
BTWN BETWEEN
C CHANNEL
CB CARRIAGE BOLT
CDF CONTROLLED DENSITY FILL
CL OR CENTERLINE
CLG CEILING
C-C CENTER TO CENTER
CF CUBIC FEET
CIP CAST-IN-PLACE
CJ CONTROL JOINT
CLR CLEAR
CMU CONCRETE MASONRY UNIT
CNTRD CENTERED
COL COLUMN
CONC CONCRETE
CONN CONNECTION
CONSTR CONSTRUCTION
CONT CONTINUOUS
CONTR CONTRACTOR
CTSK COUNTERSINK
CTR CENTER
CY CUBIC YARD
DBA DEFORMED BAR ANCHOR
DBL DOUBLE
DEG DEGREE
DIAG DIAGONAL
DIA DIAMETER
DIM DIMENSION
DL DEAD LOAD
DN DOWN
DP DEEP
DTL DETAIL
DWG DRAWING
DWL DOWEL
(E) EXISTING
EA EACH
EB EXPANSION BOLT
EF EACH FACE
EJ EXPANSION JOINT
ELEV ELEVATION
EMBED EMBEDMENT
EN EDGE NAIL
ENGR ENGINEER
EQ EQUAL
EW EACH WAY
EXP EXPANSION
EXIST EXISTING
EXTR EXTERIOR
FD FLOOR DRAIN
FDN FOUNDATION
FIN FINISH
FLR FLOOR
FN FIELD NAIL
F.O. FACE OF
F.O.C. FACE OF CONCRETE
FRMG FRAMING
FS FAR SIDE
FT FEET
FTG FOOTING
STRUCTURAL ABBREVIATIONS
GA GAUGE
GALV GALVANIZE
GL GLUED LAMINATED
GR GRADE
GWB GYPSUM WALLBOARD
H HORIZONTAL
HAS HEADED ANCHOR STUD
HDR HEADER
HGR HANGER
HORIZ HORIZONTAL
HSB HIGH STRENGTH BOLT
HSS HOLLOW STRUCTURAL SECTION
HT HEIGHT
HWH HEX WASHER HEAD
I.D. INSIDE DIAMETER
I.F. INSIDE FACE
IN INCH(ES)
INTR INTERIOR
JST JOIST
JT JOINT
JB JOIST BEARING
K KIP
KSF KIPS PER SQUARE FOOT
L OR ANGLE
LBS POUNDS
LL LIVE LOAD
LLBB LONG LEGS BACK TO BACK
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
LNTL LINTEL
LONG LONGITUDINAL
LSL LAMINATED STRAND LUMBER
LVL LAMINATED VENEER LUMBER
MAS MASONRY
MAX MAXIMUM
MB MACHINE BOLT
MECH MECHANICAL
MEZZ MEZZANINE
MFR MANUFACTURER
MIN MINIMUM
MISC MISCELLANEOUS
ML MICROLLAM
M.O. MASONRY OPENING
MTL METAL
# OR NO. NUMBER
NIC NOT IN CONTRACT
NOM NOMINAL
NS NEAR SIDE
NTS NOT TO SCALE
OC ON CENTER
O.D. OUTSIDE DIAMATER
O.F. OUTSIDE FACE
OH OVERHEAD
O-O OUT TO OUT
OPNG OPENING
OPP OPPOSITE
PAF POWDER ACTUATED FASTENER
PC PRECAST
PL OR PLATE
PLF POUNDS PER LINEAL FOOT
PCF POUNDS PER CUBIC FOOT
PLYWD PLYWOOD
PLCS PLACES
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PSL PARALLAM
PT PRESSURE TREATED
RAD RADIUS
R RISER
REINF REINFORCEMENT
REF REFERENCE
REQD REQUIRED
REQMTS REQUIREMENTS
REV REVISION
R.O. ROUGH OPENING
RM ROOM
SA SCREW-IN ANCHOR
SCHED SCHEDULE
SF SQUARE FEET
SHT SHEET
SHTG SHEATHING
SIM SIMILAR
SPCS SPACES
SPECS SPECIFICATIONS
SQ SQUARE
SSL SHORT SLOTTED
SJ SLAB JOINT
SS STAINLESS STEEL
STD STANDARD
STIFF STIFFENER
STGRD STAGGERED
STL STEEL
STUC STRUCTURAL
SYM SYMMETRICAL
TAS THREADED ANCHOR STUD
T & B TOP AND BOTTOM
THK THICK
THRD THREADED
TN TOE NAIL
T.O. TOP OF
TRANS TRANSVERSE
TS TUBE STEEL
TYP TYPICAL
UA UNDERCUT ANCHOR
UNO UNLESS NOTED OTHERWISE
V VERTICAL
(V) VERIFY
VERT VERTICAL
W/ WITH
W/O WITHOUT
WD WOOD
WF WIDE FLANGE
WP WORK POINT
WS WATERSTOP
WT STRUCTURAL TEE SECTION
WT WEIGHT
WWF WELDED WIRE FABRIC
x TIMES OR BY
Revision Schedule
Number Description Date
X
X
X
X
X
X
X
X
X
X
X
X
X
Inspect reinforcing steel including prestressing
tendons and verify placement
ACI 318 20, 25.2, 25.3,
26.6.1-26.6.3, IBC 1908.4 P
Cast-in-Place anchors in concrete ACI 318 17.8.2 P
Verify use of required mix designs
ACI 318 19, 26.4.3 & 26.4.4
IBC 1904.1,
1904.2,1908.2,1908.3
P
Sampling of fresh concrete for strength tests,
slump and air content tests and to determine
temperature of the concrete
ACI 318 26.5 & 26.12
ASTM C172 & C31
IBC 1908.10
C
Inspect concrete and shotcrete placement for
proper application techniques
ACI 318 26.5, 26.13.3.2(a)
IBC 1908.6, 1908.7 &1908.8 C
Verify maintenance of specified curing
temperature and techniques
ACI 318 26.5.3 -26.5.5
IBC 1908.9 P
Inspect prestessed concrete for application of
prestressing forces & grouting of bonded tendons ACI 318 26.10 & 26.13.3.2 C
Inspect erection of precast concrete members ACI 318 26.9 & 26.13.3.3
Verification of in-situ concrete strength prior to
stressing tendons in post-tensioned concrete ACI 318 26.11.2 P
Verification of in-situ concrete strength prior to
removal of forms and shores from elevated
beams and slabs
ACI 318 26.11.2 P
Inspect formwork for shape, location and
dimensions of the member being formed ACI 318 26.11.1.2(b)P
Placement of Reinforcing steel & Concrete in
Special Moment Frames ACI 318 18.2.5, 18.2.6, 26.13 C
Placement of Reinforcing steel & Concrete in
Special Shear Walls ACI 318 18.2.5, 18.2.6, 26.13 C
Concrete Placement for composite slabs AISC 341 J9 C
Stressing of Tendons in Post-tensioned concrete ACI 318 26.10.2 & 26.13.3.2 C
CONCRETE
System or Material Code Reference Frequency Required
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
P
Verification of Weldability if other than ASTM
A706 ACI 318 26.6.4, AWS D1.4 P
ACI 318 26.6.4, AWS D1.4 P
Inspect all other welds ACI 318 26.6.4, AWS D1.4 C
Adhesive anchors installed horizontally or
upwardly inclined and resisting sustained
tension loads
ACI 318 17.8.2.4, ICC Report C
Mechanical anchors and other adhesive anchors ACI 318 17.8.2, ICC Report P
a.
b.
c.
a.
b.
Inspect single pass fillet welds, maximum 5/16”
Welding Reinforcing Steel16.
17.Post-Installed Anchors in Hardened Concrete
X
X
X
X
X
SOILS AND FOUNDATION
System or Material Code Reference Frequency Required
1.
2.
3.
4.
5.
SPECIAL INSPECTION, TESTING AND STRUCTURAL OBSERVATION
GENERAL
The Owner or the Owner's agent shall employ an approved agency to perform inspections and testing during
construction in accordance with IBC sections 1704, 1705 and 1707 and the Statement of Special Inspections
below. These inspections are in addition to the inspections required per IBC section 110.
Special Inspectors shall be qualified persons with experience in the types of construction being inspected.
Special Inspectors shall provide written documentation of WABO or equivalent certification acceptable to the
Agency Having Jurisdiction.
Off-site work and fabrications do not require special inspection if the fabricator is registered and approved to
perform such work by the Agency Having Jurisdiction. Approval is based on the fabricator's written procedures
and quality control programs.
CONTRACTOR RESPONSIBILITIES
The Contractor shall provide reasonable access to all work requiring special inspection and notify the Inspection
Company in sufficient time to schedule such inspections. A copy of all Special Inspection reports shall be
maintained at the job site and made available upon request to the Authority Having Jurisdiction and the project
Engineer of Record.
STATEMENT OF SPECIAL INSPECTION
Special inspection to be provided per IBC 1705 for materials, systems, components and work performed are as
follows:
C = Continuous Special Inspection
P = Periodic Special Inspection
SOILS AND FOUNDATION
Provide Special Inspection for the following to determine compliance with the Geotechnical Report and the
Construction Documents:
Verify Footing Bearing Capacity
Verify Excavations are to proper depth and have
reached proper material
Classification and Testing of Compacted Fill Materials
Prior to the placement of Compacted Fill, observe
subgrade and verify the site has been prepared
properly
Verify use of proper materials, densities and lift
thicknesses during placement and compaction of fill
IBC 1705.6
IBC 1705.6
IBC 1705.6
IBC 1705.6
IBC 1705.6
P
P
P
P
C
1. Compliance with approved submittals TMS 602-16 Section 1.5 P X
2. Verify f'm prior to construction TMS 602-16 Section 1.4B P X
3.Observe preparation of grout and mortar specimens
and/or prism
TMS 602-16
Section 1.4B.2.a.3, 1.4B.2.b.3,
1.4B.2.c.3, 1.4B.3, 1.4B.4
P X
MASONRY - LEVEL 2
System or Material Code Reference Frequency Required
a. Sample panel construction TMS 602-16 Section 1.6D P X
b. Proportions of site-prepared mortar TMS 602-16 Section 2.1, 2.6A P X
c. Construction of mortar joints TMS 602-16 Section 3.3B P X
a. Grout space
TMS 602-16
Section 3.2D & 3.2F P X
b.Grade, type and size of reinforcement, connectors
and anchor bolts
TMS 602-16 Section 3.4 &
3.6A P X
c.Placement of reinforcement, connectors and anchor
bolts
TMS 602-16 Section 3.2E & 3.4
TMS 402-16 Section 6.1, 6.3.1,
6.3.6 & 6.3.7
P X
d. Proportions of site-prepared grout TMS 602-16 Section 2.6B P X
e. Construction of mortar joints TMS 602-16 Section 3.3B P
a. Slump Flow and Visual Stability Index
TMS 602.16
Section 1.5 & 1.6.3 P X
b. Size and location of structural elements TMS 602-16 Section 3.3F P X
c.
Type, size and location of anchors and details of
anchorage of masonry to structural members,
frames or other construction
TMS 402-16
Section 1.2.1(e), 6.2.1 & 6.3.1 P X
d.
Preparation, construction, and protection of
masonry during cold weather (below 40 degrees) or
hot weather (above 90 degrees)
TMS 602-16
Section 1.8C & 1.8D P X
e. Placement of grout TMS 602-16 Section 3.5 C X
4.Verify as Masonry Construction Begins
5.Verify Prior to Grouting
6.Verify During Construction
a.
Fabrication shop compliance with IBC 1704.2.5
including completeness and adequacy of quality
control procedures unless the fabricator meets the
approval requirements of IBC1704.2.5.1
AISC 360 Chapter M P X
b. Fabrication of Structural Elements
IBC 1704.2.5, AISC 360
Chapter M P X
c. Material Verification of Structural Steel IBC 1705.2.1, AISC 360 A3.1a P X
d. Material Verification of Cold Formed Steel Deck
IBC 1705.2.2,
SDI QA/QC 2017 P X
e.Material Verification of High Strength Bolts, Nuts
and Washers AISC 360 A3.3 P X
f.Material Verification of Anchor Rods and Threaded
Rods AISC 360 A3.4 P X
a. Welding Procedure Specification and Consumables AISC 360 A3.5 & N.5.4 P X
b. Welder Qualifications AISC 360 N.5.4 P X
c. Single Pass Fillet Welds 5/16” and smaller
AISC 360 N.5.4,
AWS D1.1 Section 6 P X
d.Groove welds including joint preparation,
dimensions, backing, etc.AISC 360 N5.4 P X
a. Installation of Composite Slab Decking
ICC Evaluation Report,
SDI QA/QC 2017 P X
c. Welding of Floor and Roof Decking AWS D1.3 P X
a.X
1.X
2.X
f.X
e.X
b.X
Proprietary Moment Resisting Frame Connections IBC 1705.1.1 & 2204 P
Material Verification of Reinforcing Steel for Welding ACI 318 26.6.1.2 & AWS D1.4 P
Complete and Partial Penetration Groove Welds AISC 360 N.5.4,
AWS D1.1 Section 6 C
Multipass Fillet Welds and Single Pass Fillet Welds
greater than 5/16”, Plug and Slot Welds
AISC 360 N.5.4,
AWS D1.1 Section 6 C
Pretensioned High Strength Bolts using calibrated
wrench method or turn-of-nut method without match
marking
AISC 360 Table N5.6-2 C
STRUCTURAL STEEL
System or Material Code Reference Frequency Required
Pretensioned High Strength Bolts using direct
tension indicator washers or twist-off heads AISC 360 M2.5 & N5.6 P
3.Fabrication
4.Welding
g. Welding of Stair and Railing Systems AWS D1.1 Section 6 P
5.High-Strength Bolting
6.Composite Construction
b. Installation of Roof Decking
ICC Evaluation Report,
SDI QA/QC 2017 P X
e.Placement & installation of Headed Studs with
automatic timed stud welding machine AWS D1.1 Section 7 P
d.XWelding of Reinforcing Steel ACI 318 26.6.4 & AWS D1.4 P
f.Placement & installation of Headed Studs with hand
welding AWS D1.1 Section 7 C
Welding Procedure Specification and Consumables AWS D1.3 P
Welder Qualifications AWS D1.3 P
Cold formed roof and floor deck welding AWS D1.3
Welded framing connections AWS D1.3
Cold-formed steel trusses spanning 60’ or greater IBC 1705.2.4
COLD FORMED STEEL
System or Material Code Reference Frequency Required
1.
2.
3.
4.
5.
X
X
X
X
P
P
P
Fabrication of prefabricated structural elements IBC 1704.2.5 P
Prefabricated Wood Shear Walls IBC 2306.3 & ICC Report P
WOOD
1.X
System or Material Code Reference Frequency Required
2.
3.
X
X
Fabrication of high-load diaphragms:
- Verify panel grade and thickness.
- Verify nominal size of framing members at
adjoining panel joints.
- Verify nail or staple diameter and length, number
of fastener lines and spacing between fasteners at
each line and at edge margins.
IBC 1705.5.1 & 2306.2 P
Verification of the installation of temporary and
permanent restraint bracing for individual trusses
spanning 60’ or greater
IBC 1705.5.2 P4.
Structural steel of the Seismic Force Resisting
Systems in structures assigned to SDC B, C, D, E or
F (excluding steel structures in SDC B or C designed
with R=3)
IBC 1705.12.1.1
AISC 341-16 Tables J6-1,
J6-2 and J6-3
P
Structural steel elements of the Seismic Force
Resisting Systems including struts, collectors, chords
in structures assigned to SDC B, C, D, E or F
(excluding steel structures in SDC B or C designed
with R=3)
IBC 1705.12.1.2
AISC 341-16 Tables J6-1,
J6-2 and J6-3
P
High Strength Bolt Installation of the Steel Seismic
Force Resisting Systems in structures assigned to
SDC C, D, E or F (excluding steel structures in SDC C
designed with R=3)
AISC 341-16 Tables J7-1,
J7-2 and J7-3 P
Reduced Beam Section in steel moment resisting
frames AISC 341-16 Table J8-1 P
Protected Zones in steel seismic force resisting
systems AISC 341-16 Table J8-1 P
Anchorage of storage racks 8’ in height and greater in
structures assigned to SDC D, E or F
IBC 1705.12.7 ASCE 7
Section 15.5.3 P
Cold Formed Steel
IBC 1705.12.3 P
For screw attachment, bolting, anchoring and other
fastening of components within the seismic force
resisting system including shear walls, braces,
diaphragms, collectors and hold-downs.
Structural Wood
IBC 1705.12.2 CField gluing of diaphragm and shear wall elements of
the seismic force resisting system
IBC 1705.12.2 P
Nailing, bolting, anchoring and other fastening of
elements of the seismic force resisting system
including shear walls, diaphragms and chords,
collectors, braces, shear wall anchorage and holdowns
(not required when fastener spacing of sheathing > 4")
Architectural Components
IBC 1705.12.5 P
Erection and anchorage of exterior cladding, interior
and exterior veneer weighing more than 5 psf in
structures assigned to SDC D, E & F
IBC 1705.12.5 P
Erection and anchorage of interior nonbearing walls
weighing more than 15 psf in structures assigned to
SDC D, E & F
IBC 1705.12.5 P
Erection and anchorage of exterior cladding, interior
and exterior nonbearing walls, and interior and
exterior veneer exceeding 30' in height above grade
in structures assigned to SDC D, E & F
IBC 1705.12.5.1 PAnchorage of access floors in structures assigned to
SDC D, E & F
ASCE7 Section 13.5.6 PInstallation and anchorage of suspended ceiling
systems
ASCE7 Section 13.5.1 P
Installation, mounting and other seismic restraints for
designated architectural systems and their
components
Electrical Components
IBC 1705.12.6 P
Anchorage of electrical equipment for emergency and
standby power systems in structures assigned to SDC
C, D, E & F
IBC 1705.12.6 PAnchorage of all electrical equipment in structures
assigned to SDC E & F
IBC 1705.12.6 P
Installation and anchorage of piping systems designed to
carry hazardous materials and their associated
mechanical units in structures assigned to SDC C, D, E
& F
IBC 1705.12.6 P
Installation and anchorage of ductwork designed to
carry hazardous materials in structures assigned to
SDC C, D, E & F
Mechanical Components
IBC 1705.12.6 P
Installation and anchorage of vibration isolating
systems in structures assigned to SDC C, D, E & F
where the Construction Documents require a nominal
clearance of ¼” or less between the equipment
support frame and the restraint
Minimum installation clearance of components,
including duct work, piping systems and their
structural supports where automatic fire sprinkler
systems without flexible hose fittings are installed in
structures assigned to SDC C, D, E & F
IBC 1705.12.6.6 P
SPECIAL INSPECTIONS FOR SEISMIC RESISTANCE
a.X
System or Material Code Reference Frequency Required
X
X
X
X
X
X
X
X
X
X
X
X
X
b.
c.
d.
e.
f.
a.
b.
a.
b.
c.
d.
e.
f.
a.
b.
a.
b.
c.
d.
Structural Steel1.
2.
a.During welding of elements of the seismic force
resisting system.
b.IBC 1705.12.3 P
3.
4.
5.
6.
TESTING FOR SEISMIC RESISTANCE
System or Material Code Reference Required
Structural steel in the seismic force resisting system of buildings and
structures assigned to SDC B, C, D, E or F (not required if R=3 system)IBC 1705.13.1.1
Structural steel elements including struts, collectors and chords in the
seismic force resisting system of buildings and structures assigned to SDC
B, C, D, E or F (not required if R=3 system)
IBC 1705.13.1.2
Document all accepted and rejected connections of the seismic resisting
system
IBC 1705.13.1
AISC 341 J7
Provide MT testing of the column k-area of the web where welding of
doubler plates, continuity plates or stiffeners has been performed.
IBC 1705.13.1
AISC 341 Table J6.3
Provide UT testing on 100% CJP groove welds in materials 5/16” and
greater (For Ordinary Moment Frames, only the demand critical welds
need to be tested)
IBC 1705.13.1
AISC 341 J6.2a
Provide MT testing on 25% of all beam-to-column CJP groove welds
in materials 5/16” and greater (For Ordinary Moment Frames, only
the demand critical welds need to be tested)
IBC 1705.13.1
AISC 341 J6.2a
Provide UT testing of base metal thicker than 1 ½” loaded in tension
in tee and corner joint where the connected material is thicker than ¾”
IBC 1705.13.1
AISC 341 J6.2c
Provide MT testing of thermally cut surfaces of beam copes and
access holes in welded splices and connection when the flange
thickness exceeds 1 ½” for rolled shapes or when the web thickness
exceeds 1 ½” for built-up shapes
IBC 1705.13.1
AISC 341 J6.2d
Provide MT testing of any weld and adjacent area of the reduced
beam section (RBS) cut surface that has been repaired by welding or
on the base metal of the RBS cut surface if a sharp notch has been
removed by grinding
IBC 1705.13.1
AISC 341 J6.2e
Provide MT testing at the end of welds where weld tabs have been
removed
IBC 1705.13.1
AISC 341 J6.2f
X
X
X
X
X
X
X
X
X
X
1.
2.
a.
b.
c.
d.
e.
f.
g.
a.
3.Structural Steel
4.High Strength Bolting
737 BISHOP STREET, SUITE 1860
HONOLULU, HI 96813
808-352-5299
OWNER:
523 EAST THIRD AVENUE
SPOKANE, WA 99202
P 509.323.9292
F 509.747.7115
HOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 99216SPECIAL INSPECTIONS
& TESTING
S003
FSC PROJECT NO. 21012
PERMIT SET
5/31/2024
GL8 Mirabeau
Point, LLC
10909 E. Pierce Lane
Spokane, WA 99206
(509) 919-0901
Revision Schedule
Number Description Date
T.O.F.T.O.F.
FIN SLAB
T.O.F.
T.O.F.T.O.F.
FIN SLAB
T.O.C.
T.O.S.FTGDEPTHTYP1" CLRSEENOTE 3NOT PASSPIPES SHALLMIN3 1/2"MIN.4"MIN6"NOTE 3
SEE
MIN
9"
MIN
1'-6"TYP1" CLR1 1/2
1
TYP PIPE IN
SLEEVE CONC FDN
STEM WALL
DEPTHFTGTYP PIPE
IN SLEEVE
MONOLITHIC
CONC POUR
WITH FTG OR
1000-PSI
MIN CDF
NO EXCAVATION
BELOW THIS LINE
PARALLEL
TRENCH
EXCAVATION
NOTES:
1. NO PIPES, CONDUIT, ETC. SHALL PASS THROUGH OR UNDER COLUMN PAD FOOTINGS.
2. FOR PIPES, CONDUIT, ETC. PASSING WITHIN THE FOOTING THICKNESS, STEP FOOTING DOWN AS REQ'D TO PASS THRU STEM WALL.
3. VERTICAL & HORIZONTAL SPACING BETWEEN ADJACENT PIPES SHALL BE 1 1/2xLARGEST SLEEVE DIAMETER, BUT NOT LESS THAN 6".
4. FOR PIPES MORE THAN 3'-0" BELOW FOOTING, COMPACT BACKFILL OVER PIPE TO MINIMUM 90% AND OMIT THICKENED CONC SECTION.SEENOTE 4UNLESS NOTED
OTHERWISE IN
GEOTECH REPORT
BAR SIZE REGULAR
BARS
TOP
BARS
REGULAR
BARS
REGULAR
BARS
TOP
BARS
TOP
BARS
HOOKED BARSf'c = 3000 PSI f'c = 4000 PSI f'c = 5000 PSI
3000 PSI 4000 PSI 5000 PSI
9"7"7"
11"10"9"
14"12"11"
17"15"13"
19"17"15"
22"19"17"
25"22"19"
28" 24"22"
31"27"24"
#3
#4
#5
#6
#7
#8
#9
#10
#11
Ld 17"22"15"19"13"17"
SPLICE 22"28"19"24"17"22"
22"17"25"19"29"22"Ld
SPLICE
Ld
SPLICE
Ld
SPLICE
Ld
SPLICE
Ld
SPLICE
Ld
SPLICE
Ld
SPLICE
Ld
SPLICE
29" 37"25"32"22"29"
28"22"31"24"36"28"
36"47"31"40"28"36"
33"43"29"37"26"33"
43"56"37"48"33"43"
48"63"42"54"37"49"
63"81"54"70"49"63"
55"72"48"62"43"55"
72"93"62"80"55"72"
62" 81"54"70"48"63"
81"105"70"91"63"81"
70"91"61"79"54"70"
91"118"79"102"70"91"
78"101"67"87"60"78"
101"131"87"113"78"101"
(Ldh)
NOTES:
1. TABULATED VALUES ARE BASED ON ACI 318-14 FOR GRADE 60 UNCOATED
REINFORCEMENT AND NORMAL-WEIGHT CONCRETE.
2. TOP BARS ARE HORIZONTAL BARS WITH MORE THAN 12" OF FRESH CONCRETE
CAST BELOW THE BARS.
3. TABULATED VALUES REQUIRE THE FOLLOWING:
CLR COVER > 1db
BAR SPACING > 2db (BEAMS & COLUMNS)
> 3db (ALL OTHER MEMBERS)
4. SPLICE LENGTH OF DIFFERENT SIZED BARS SHALL BE THE LARGER OF THE
FOLLOWING:
A. Ld OF LARGER BAR
B. SPLICE LENGTH OF SMALLER BAR
CRITICAL
SECTION
(COLD JT)
CRITICAL
SECTION
(COLD JT)
Ld Ldh SPLICE
LENGTH
SPCGBARSTD DEVELOPMENT HOOK DEVELOPMENT LAP SPLICE
90° HOOK
180° HOOK
PRIMARY REINFORCEMENT
STIRRUPS, TIES & CROSSTIES
DD
D
D
#3 - #5 : D = 4 db
#6 - #8 : D = 6 db
#3 - #5
#6 - #8
D
D
D
D
D
D
DD
DD
db = BAR DIAMETER
D = INSIDE BEND DIAMETER (INCLUDING SPRINGBACK)
4 db
2½"
MIN 12 db#3 - #8 : D = 6 db
#9 - #11 : D = 8 db 3" MIN6 db 3" MIN6 db
3" MIN
6 db
12 db
3" MIN6 db 3" MIN6 db2½" MIN
4 db
1
6 MIN
TYP VERT
BARS SPLICELENGTHPLAN - SINGLE CURTAIN
ALT SIDES
SPLICE
LENGTH
SPLICELENGTHSPLICE
LENGTH
SPLICELENGTHPLAN - DOUBLE CURTAIN
STD
HOOK
NOTE 3
CROSS
WALL
NOTE 3
STD
HOOK
CROSS
WALL
STD HOOK
2 VERT
BARS MIN
2 VERT
BARS MIN
NOTES:
1. CORNER BARS SHALL MATCH SIZE & SPACING OF HORIZONTAL REINFORCEMENT, UNO. CORNER BARS
AT INTERSECTING WALLS SHALL MATCH HORIZONTAL REINFORCEMENT OF CROSS WALL.
2. SPLICE LENGTH SHALL BE PER TYPICAL LAP-SPLICE SCHEDULE FOR TENSION REINFORCEMENT.
3. PROVIDE ¾" CHAMFER AT OUTSIDE WALL CORNERS NOT IN CONTACT WITH SOIL.
SPLICE
LENGTH
SPLICE
LENGTH
SPLICELENGTHCOMPACTED BASE
NOTES:
1. SEE ARCHL DRAWINGS FOR VAPOR BARRIER
REQUIREMENTS. MINIMIZE VAPOR BARRIER
PENETRATIONS WITH FORM STAKES, NAILS, SPIKES
OR OTHER CONSTRUCTION DEVICES TO THE FULLEST
EXTENT PRACTICAL.
2. SEE GENERAL STRUCTURAL NOTES FOR SLAB JOINT
LAYOUT AND FIBER REINFORCEMENT REQUIREMENTS.
3. SEE GEOTECHNICAL REPORT FOR COMPACTED BASE
AND PREPARED SUB BASE REQUIREMENTS.
4. SLABS POURED DIRECTLY ON VAPOR BARRIER MAY
TAKE LONGER TO CURE THAN SLABS NOT IN DIRECT
CONTACT WITH VAPOR BARRIER.
5. WHEREVER POSSIBLE, ALIGN JOINTS WITH RE-
ENTRANT SLAB CORNERS AND INTERIOR COLUMNS.
6. SEE ARCHL DRAWINGS FOR JOINT SEALANT
REQUIREMENTS.
7. AT CONTROL JOINTS, SAWCUT ALONG SHORT
DIRECTION OF POUR FIRST. FOR EARLY-ENTRY
DRY-CUT SAWS, USE AS SOON AS POSSIBLE WITHOUT
CAUSING RAVELING OF CONCRETE EDGES.
PREPARED SUB BASE
PUNCTURE RESISTANT
VAPOR BARRIER
SAWCUT CONTROL JOINT FORMED CONSTRUCTION JOINT TSEALANT WELL
(1/8" TO 1/4"
WIDTH)
TRUE STRAIGHT LINE
LOAD-TRANSFER
DOWELS AT
MID-DEPTH
(SEE SCHED)
TRUE STRAIGHT LINE
SAWCUT JOINT
(1/8" TO 1/4"
WIDTH)T/43/4"SEE PLANDSEEPLANMIN
1.5xH
CONC WALL
AS OCCURS
WALL REINF
MATCH WALL
REINF
2'-0" MAXHFTG REINF
SEE PLAN
MATCH FTG
REINF
STEEP AS
POSSIBLE 3" MI NMIN
D
SEE PLAN S S DEVELOPMENT
LENGTH, SEE SCHED
LAP SPLICE, SEE
SCHED
*
**
EA END
**
*
**
*
PLAN - ISOLATION JT
℄COL
& FTG
SEE PLANS FOR FTG
SIZE AND REINF
'X' = 1 1/2" UNO
= 1 3/4" @ 7/8"ø & 1"ø AR
BASE PL W/ 4-¾"ø AR
IN OVERSIZE HOLES
ON 1½" GROUT (UNO)
- SEE AR SCHED S JS JS JS J
SLAB
JOINTS
ISOLATION JOINT
USING SQUARE OR
ROUND FORM
SEE PLAN
HSS COL
CLR3"MIN2" CLRUNO FILL ISOLATION JOINT
W/ CONC TO MATCH
ADJACENT SLAB
t
SEE
SCHED
X
X X
XB
* BASE PL CAPACITY BASED ON AISC STEEL DESIGN GUIDE #1,
2ND EDITION, ASSUMING RIGID PLATE ON A PEDESTAL.
COLUMN DIA OR
LEAST WIDTH
B ≤3.5"
BASE PL
5/8" THICK
WELD
SIZE (t)
1/4"
ASD LOAD
CAPACITY *
40 KIPS
B ≤4"3/4" THICK 1/4" 65 KIPS
B ≤5"7/8" THICK 5/16" 100 KIPS
B ≤8"1 1/8" THICK 260 KIPS
B ≤10"1 1/4" THICK 350 KIPS
SQ OR RECT HSS ROUND HSS
8"5/16"
5/16"
B ≤6"1" THICK 5/16" 155 KIPS
MIN
2½"MIN2½"B
2-#4x3'-0" 1½" CLR
FROM TOP SURFACE
S J S JSLAB JOINT
OR EDGE
OR RECESS
RE-ENTRANT CORNER
OR SLAB OPENING DISCONTINUOUS JOINT
NOTES:
1. SEE GENERAL STRUCTURAL NOTES AND TYPICAL
DETAILS FOR JOINTING PARAMETERS AT SLABS ON
GRADE. ALSO SEE ARCH'L DRAWINGS FOR SPECIFIC
JOINT LOCATIONS.
2. RE-ENTRANT CORNERS AND DISCONTINUOUS JOINTS
SHALL BE AVOIDED IF POSSIBLE. 2" 2"NOTES:
T.O.F. OR
STRAIGHT ROD W/
HEAVY HEX NUT
(THREAD EA END)
HEADED
BOLT
ASTM A563 HEX NUT &
ASTM F844 WASHERS
OR PL WASHERS
PROJEMBEDMENTBOLT OR ROD LENGTHGROUTNON-SHRINK EQ3/16 TACK
BOLT/ROD
SIZE
BASE PL
HOLE SIZE
MINIMUM
EMBED (UNO)
MINIMUM
WASHER
1/2"ø 1"ø 5"ASTM F844
ASTM F8446"
8"
8"
9"
1 1/8"ø5/8"ø
3/4"ø
7/8"ø
1"ø
1 5/16"ø
1 9/16"ø
1 7/8"ø
PL1/4 x 2"
PL5/16 x 2 1/2"
PL3/8 x 3"
1. HEADED BOLTS AND STRAIGHT RODS SHALL BE ASTM F1554
(GRADE 36, UNO). ASTM A307 HEADED BOLTS SHALL NOT BE USED.
2. HEADED BOLTS OR STRAIGHT RODS CAN BE USED
INTERCHANGEABLY AT THE CONTRACTOR'S OPTION.
3. PLATE WASHERS SHALL BE ASTM A36 W/ HOLES THAT ARE 1/16"
LARGER THAN BOLT/ROD DIAMETER.
4. SQUARE OR CIRCULAR WASHERS MEETING THE SIZE SHOWN ARE
ACCEPTABLE.
5. GALVANIZE AT EXPOSED EXTERIOR CONDITIONS.
SLAB
DEPTH
(T)
ROUND BAR DIAMOND PLATE
SIZE SPACING SIZE SPACING
4"½"⌀x10"16" OC ¼x4½x4½ 18" OC
4"<T≤6" ¾"⌀x10"12" OC ¼x4½x4½ 18" OC
1"⌀x13"3/8x4½x4½ 18" OC
1¼"⌀x15"¾x4½x4½ 20" OC
6"<T≤8"
8"<T≤11"
12" OC
12" OC
ROUND BAR NOTES:
1. PROVIDE SMOOTH STEEL DOWELS W/ SAWN & DEBURRED END
EDGES. GREASE OR WRAP ONE END TO PREVENT BOND.
2. DOWELS SHALL BE SUPPORTED SO AS TO REMAIN LEVEL AND
PERPENDICULAR TO JOINT LINE.
3. DOWELS SHALL BE PLACED NO CLOSER THAN 12" FROM JOINT
INTERSECTIONS.
EITHER ROUND-BAR OR DIAMOND-PLATE DOWELS MAY BE USED AT
CONTRACTOR'S OPTION.
DIAMOND PLATE NOTES:
1. DIAMOND-DOWEL SYSTEM SHALL BE PROVIDED BY PNA
CONSTRUCTION TECHNOLOGIES OR APPROVED EQUIVALENT.
2. INSTALL DOWELS AS RECOMMENDED BY MANUFACTURER.
DOORS & STOREFRONT
RECESS @
COORD SETBACK AS
OCCURS W/ ARCHL &
STRUC DTLS
#4 SLAB DWLS @
18" OC MAX (3 MIN)#4 EA
END
2'-6"
PLAN
#4 HORIZ
STEM WALL
12"2'-6"1
1
SLAB DWLSSECTION
EXTR CONC WALK @
DOORS BY OTHERS
(PROVIDE 1/2"øx10"
SMOOTH DWLS @ 12" OC)UNO8"1 1/2"CLR2"F.O.C.
EXTEND ALL VERT BARS INTO SLAB
@ DOORS (FOR DBL MATS, EXTEND
VERT BARS ON INSIDE FACE ONLY)
2-#4 HORIZ,
UNO
RECESSED CONC STEM WALL
W/ REINF PER FDN DETAILS
SLAB ON GRADE
SEE PLAN FOR
THICKNESS & REINF
NOTES:
1. SEE MECH PLANS FOR PAD THICKNESS, DIMENSIONS, AND LOCATIONS.
REINFORCE PAD W/ #3 @ 12" OC EA WAY, UNO (#4 @ 12" OC FOR SLABS > 5½").
2. PAD FOOTPRINT SHALL BE AT LEAST 4" GREATER IN ALL DIRECTIONS THAN
SUPPORTED EQUIPMENT, UNLESS NOTED OTHERWISE IN MECH DWGS.
#3 DOWEL @ 12" OC TYP
@ PERIMETER, DRILL &
SET IN ADHESIVE
3 "EQ MIN3½"2½"
6"
TYP
¾" CHAMFER, TYP
737 BISHOP STREET, SUITE 1860
HONOLULU, HI 96813
808-352-5299
OWNER:
523 EAST THIRD AVENUE
SPOKANE, WA 99202
P 509.323.9292
F 509.747.7115
HOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 99216TYPICAL DETAILS -
CONCRETE
S004
FSC PROJECT NO. 21012
PERMIT SET
5/31/2024
GL8 Mirabeau
Point, LLC
10909 E. Pierce Lane
Spokane, WA 99206
(509) 919-0901
SCALE:NTS1TYPICAL PIPE AND/OR CONDUIT CLEARANCES AT FOUNDATION
2150 000-0002 SCALE:NTS3TYPICAL DEVELOPMENT AND LAP-SPLICE LENGTHS FOR TENSION REINFORCEMENT IN CONCRETE, UNO
3200 000-0003
SCALE:NTS6TYPICAL REBAR BENDING DETAILS
3200 101-0003 SCALE:NTS7TYPICAL CONCRETE WALL REINFORCING @ INTERSECTION, CORNER & BAR SPLICE
3200 101-0001 SCALE:NTS9TYPICAL CONCRETE SLAB ON GRADE W/ FIBER REINFORCEMENT
3346 102-0001
SCALE:NTS12TYPICAL STEPPED FOOTING
3200 001-0001 SCALE:NTS13TYPICAL FOOTING AND BASE PLATE AT INTERIOR HSS COLUMNS
3346 000-0007 SCALE:NTS15
TYPICAL REINFORCING AT RE-ENTRANT CORNERS AND
DISCONTINUOUS JOINTS IN EXPOSED SLABS ON GRADE
3346 102-0002
SCALE:NTS17TYPICAL ANCHOR ROD (AR) REQUIREMENTS
3346 000-0009
SCALE:NTS11
TYPICAL SCHEDULE FOR LOAD-TRANSFER DOWELS
AT SLAB-ON-GRADE CONSTRUCTION JOINTS
3200 000-0002
SCALE:NTS19TYPICAL SLAB EDGE AT EXTERIOR DOORS & STOREFRONT, UNO
3346 102-0000SCALE:NTS16TYPICAL INTERIOR EQUIPMENT PAD AT SLAB ON GRADE
3346 000-0003
Revision Schedule
Number Description Date
T.O.PL
SEE ARCH
NOTES:
1. NAILS SPECIFIED IN STRUCTURAL DRAWINGS AND NOTES REFER
TO "COMMON" TYPE NAILS (TYPICAL, UNO).
2. NAILS THAT MATCH ONE OF THE TWO "NAIL DIMENSIONS" ARE NOT
ACCEPTABLE.
3. FOR NAILING NOT SHOWN IN THE CONSTRUCTION DRAWINGS, USE
"COMMON" NAILS AS INDICATED IN THE IBC FASTENING SCHEDULE.
LENGTH (L)DIAMETER (D)
"COMMON" NAIL
DESIGNATION
NAIL DIMENSIONS
NAIL SIZE REQUIREMENTS
6d 0.113"2"
8d 0.131"2-1/2"
10d 0.148"
12d 0.148"
16d 0.162"
20d 0.192"
3"
3-1/4"
3-1/2"
4"
NAIL SPACING REQUIREMENTS
'DIMENSION': DESCRIPTION
'A': EDGE DISTANCE 2.5D (1" MIN)
'B': SPACING BETWEEN ROWS
'C': SPACING BETWEEN NAILS IN A ROW
'D': END DISTANCE
5D (1-1/2" MIN)
15D (2-1/2" MIN)
15D (2-1/2" MIN)
'D''B''A'FRAMING MEMBERWIDE FACE OF'C'SEE NOTE 4
2x DIAMETER
OR LARGEST
HOLE (MIN)
TO EDGE
1" MIN
SEE PLAN
2x WALL DISTEDGEMAX HOLE SIZE
SEE TABLE
12" MIN
NOTES:
1. VERIFY ALL PLUMBING WALL LOCATIONS W/ ARCHL DRAWINGS.
2. PLACE AN ADDITIONAL STUD BELOW JOIST BEARING LOCATION
ADJACENT TO HOLE IN TOP PLATE.
3. STRUCTURAL WALLS INCLUDE LOAD BEARING WALLS, SHEAR
WALLS, AND EXTERIOR WALLS.
4. IF LARGER DIAMETER HOLES ARE DESIRED IN TOP PLATES OF
SHEAR WALLS, CONTACT EOR FOR REINFORCEMENT OPTIONS.
5. BUILT-UP STUDS AT HEADERS/BEAMS AND AT HOLDOWNS.
6. HOLES ARE NOT ALLOWED IN THE MIDDLE 1/3 OF THE STUD
HEIGHT WITHOUT PRIOR APPROVAL FROM THE EOR.
7. NOTCHING OF STUDS AND/OR PLATES IS NOT ALLOWED WITHOUT
PRIOR APPROVAL OF THE EOR.
8. HOLE DIAMETER IN STRUCTURAL WALL STUDS CAN BE INCREASED
50% IF STUDS ARE DOUBLED, WITH NO MORE THAN TWO
CONSECUTIVE DOUBLE STUDS.
WALL STUDS
MAX DRILLED HOLE SIZE
2x4 1"⌀
STRUCTURAL
WALLS3
BUILT-UP
STUDS3
NON-STRUCT
WALLS
STUD
SIZE
7/8"⌀2"⌀
2x6 2"⌀1-3/8"⌀3-1/4"⌀
2x8 3"⌀1-3/4"⌀4-1/4"⌀
STUDS
MAX DRILLED HOLE SIZE
TOP & BOT PLATES
PLATE
SIZE
SHEAR
WALLS
OTHER
WALLS
MIN EDGE
DISTANCE
2x4 1"⌀1-1/2"⌀1"
2x6 2"⌀2-1/2"⌀1-1/2"
2x8 3"⌀3-1/4"⌀2"
TOP & BOT PLATES
(SHEAR PLATES)
EQ EQ
MAX
1/2"
MAX
1/2"
STD CUT WASHER IF PL
WASHER IS SLOTTED
PL WASHER W/ OPTIONAL
DIAGONAL SLOT
NOTE:
OPTIONAL DIAGONAL SLOT IN PL WASHER
SHALL BE NO WIDER THAN 3/16" OVER BOLT
DIAMETER W/ MAX LENGTH OF 1-3/4"
PL WASHER 1/4x3x0'-3" @ 2x4 STUDS
ALT: SIMPSON BP5/8-3 OR BPS5/8-3
PL1/4x3x0'-4 1/2" @ 2x6 STUDS
ALT: SIMPSON BPS5/8-6
PLAN
4'-0" MIN LAP W/ 8-16d
16d EA SIDETYP 16d
@ 16" OC
PLATE SPLICE
TO OCCUR OVER
STUDS, TYP
℄COL
CONDITION @
WALL CORNERS
2x STUD
EA SIDE
1/2"⌀THREADED ANCHOR
STUD (TAS) @ 24" OC TYP
EA 2x STUD
(ALT: SIMPSON TBP/TF
SCREWS @ 12" OC)
HSS COLUMN
SEE SCHED
2x FULL-HT STUDS
SEE SCHED
2x CRIPPLE STUDS
2-16d MIN EA SIDE
INTO HEADER SILLS
DBL TOP PLATE
HEADER
SEE PLAN
CONT 2x SILL @ WINDOWS
(DBL 2x @ OPNGS 8'-0" &
WIDER, UNO)
16d SINKER
@ 16" OC TYP
2-16d MIN EA SIDE
INTO HEADER
PROVIDE CRIPPLE STUDS TO
MATCH JACK STUDS ABOVE FLOOR JOIST
1/2" GAP
SIMPSON DTC
TRUSS CLIP EA SIDE
@ 8'-0" OC MAX
STUD WALL
(WOOD OR STEEL)
FLOOR JOIST
2-10d EA END
(TYP)
STUD WALL
(WOOD OR STEEL)
SIMPSON DTC
TRUSS CLIP
EA SIDE
1/2" GAP
2x6 @ 8'-0" OC
MAX (NOTCH @
JOIST EA END)
JOIST PERPENDICULAR TO WALL JOIST PARALLEL TO WALL
2x8 WEB
STIFFENERS EA SIDE
W/ 5-10d NAILS-
INSTALL PER MFRS
INSTRUCTIONS
∠3x3x1/4x0'-6" W/ 2-5/8"⌀
BOLTS TO JOIST
(WASHERS REQD)
HANGER ROD THRD EA END
- MAX LOAD 200# PER ROD
'I' JST
2x JOIST
WASHER
PL1/4x3x0'-3"
2x BLKG W/
3-16d EA END
HANGER ROD
THRD EA END
- MAX LOAD
200# PER ROD
∠3x3x1/4x1'-0"
MIN W/ 2-5/8"⌀
MB @ 9" OC
2x JOIST
I-JOIST
1 1/2" 8"SHEATHING (24/0)
SEE PLAN
2-2x STUDS OR 4x POST
EDGE NAILING - ALL EDGES,
ALL SHEETS SEE SCHEDULE
2x OR 3x SOLID BLKG
@ ALL PANEL EDGES
FIELD NAILING @
INTERMEDIATE
SUPPORTS 12" OC TYP
HOLDOWN WHERE
CALLED OUT ON PLAN
SILL BOLTS
2'-0" MAX
1'-3" MINMIN7"CONC
STEM
WALL
W/ PL WASHERS
SEE DETAILS
PARTIAL WALL ELEVATION
ELEVATION NOTES:
1. MIN EDGE DISTANCE FOR NAILS SHALL BE 3/8"
2. MIN SHEATHING SHEET SIZE SHALL BE 2'-0"x4'-0"
3. NAILS SHALL BE INSTALLED FLUSH TO SURFACE OF
SHEATHING AND SHALL NOT BE OVERDRIVEN
4. NAILS SHALL BE COMMON WIRE TYPE OR APPROVED EQUAL
5. INSTALL PANELS WITH LONG DIMENSION HORIZONTAL UNO
6. PROVIDE SHEATHING AND SPECIFIED NAILING FOR THE
FULL LENGTH OF WALL AS INDICATED ON THE PLANS
7. PROVIDE HOT-DIPPED GALVANIZED NAILS FOR FASTENING
INTO PRESSURE TREATED SILL PLATES
8. PROVIDE EDGE NAILING FULL HEIGHT TO HOLDOWN POSTS.
PROVIDE EDGE NAILING TO EACH 2x STUD OR BUILT-UP
MULTI 2x HOLDOWN POSTS
SHEAR WALL SCHEDULE
SHEATHING & FASTENING PLATE FASTENING
WALL
MARK
APA-RATED
PLYWOOD/OSB
SHEATHING (1)
NAIL
SIZE
(2)
EDGE NAIL
(EN)
SPACING
FIELD NAIL
(FN)
SPACING
FRAMING AT
ADJOINING PANEL
EDGES (4)
BOTTOM PLATE
NAILING TO
WOOD BELOW
2-ROWS 16d @ 8" OC (5)
1
RIM BOARD OR
BLKG TO PLATE
BELOW
2 SILL PLATE
BOLTING
5/8"⌀AB @ 24" OC
P1-6
P1-4
P1-3
15/32" - ONE SIDE
15/32" - ONE SIDE
15/32" - ONE SIDE
8d 6" OC 12" OC 2x
8d 4" OC 12" OC 2x
8d 3" OC 12" OC 2x
16d @ 6" OC
16d @ 8" OC
A35 @ 12" OC
A35 @ 16" OC
A35 @ 24" OC
5/8"⌀AB @ 32" OC
5/8"⌀AB @ 48" OC
NOTES:
1. 5/8" APA-RATED FRT SHEATHING AND 10d NAILS REQUIRED AT ALL EXTERIOR SHEAR WALLS.
2. COMMON NAILS SHALL BE USED UNLESS NOTED OTHERWISE.
3. AT ADJOINING PANEL EDGES, NAILS SPACED @ 2" OC INTO A SINGLE 3x MEMBER SHALL BE STAGGERED.
4. DBL 2x STUDS SHALL BE FASTENED TOGETHER WITH 2-ROWS OF 10d COMMON NAILS @ 6" OC.
5. WHERE BOTTOM PLATE REQUIRES 2 ROWS OF NAILING, PROVIDE ADDITIONAL JOIST, RIM BOARD, OR
BLKG AND STAGGER NAILS. FACE NAIL WITH 2-ROWS OF 10d @ 6" OC.
6. PANEL JOINTS ON EACH FACE TO BE OFFSET TO FALL ON DIFFERENT FRAMING MEMBERS.
T.O. SHTG
RIM BOARD,
JOIST, OR
BLKG
SEE NOTE 5
CORRESPONDS TO
SHEAR WALL BELOW
(48" OC MAX)
1
2
2-ROWS 16d @ 4" OC (5)5/8"⌀AB @ 16" OC
P2-6
P2-4
P2-3
15/32" - BOTH SIDES (6)10d 6" OC 12" OC 2x
4" OC 12" OC 2x
3" OC 2x
16d @ 3" OC
16d @ 4" OC
-
A35 @ 6" OC
A35 @ 24" OC
5/8"⌀AB @ 16" OC
5/8"⌀AB @ 32" OC
15/32" - BOTH SIDES (6)
15/32" - BOTH SIDES (6)
5/8" - BOTH SIDES (6)P2-3-5/8 2-ROWS 16d @ 3" OC (5)5/8"⌀AB @ 12" OC
10d
12" OC
3" OC 2x -
10d
10d 12" OC
HEADER
WINDOW OPNG
4x6 BLKG BTWN
STUDS @ STRAPS
EA END
2'-6" MIN
CONT SILL
PER TYP DTL
CONT C16 COIL
STRAP TOP & BOT
(NAIL OVER SHTG)
PER TYP DTL
2x CRIPPLE
2-2x FULL HT JAM STUD MIN
(3-2x FULL HT AS REQ'D BY
TYP EXTR WALL FRMG DTL)
PROVIDE STGRD EN ON
ALL FULL FULL HT JAM STUD
NOTES:
1. SEE SHEAR WALL
SCHEDULE FOR REQUIRED
FRAMING MEMBERS
BASED ON WALL TYPE
2. SEE TYPICAL SHEARWALL
ELEVATION FOR GENERAL
FRAMING INFORMATION
NOT GIVEN
3. SHEATH & NAIL ABOVE &
BELOW OPENING TO
MATCH SHEARWALLS ON
EACH SIDE
4. CS STRAP REQ'D BOTH
SIDES OF WALL AND
DOUBLE SIDED (P2-x)
SHEAR WALLS
EDGE NAILING (EN) -
ALL SUPPORTED PANEL
EDGES & DIAPHRAGM
PERIMETER
FIELD NAILING (FN)
@ INTERMEDIATE
SUPPORTS
APA RATED SHTG
LAYOUT
PROVIDE 2x 4 FLAT
BLOCKING @ ALL
PANEL EDGES @ AREAS
IDENTIFIED AS
BLOCKED PLYWOOD
DIAPHRAGMS ON PLAN
NOTES:
1. MIN EDGE DISTANCE FOR NAILS SHALL BE 3/8".
2. MIN SHEATHING SHEET SIZE SHALL BE 2'-0" x 4'-0".
3. NAILS SHALL NOT BE OVERDRIVEN.
4. NAILS SHALL BE COMMON WIRE TYPE OR APPROVED EQUAL.
5. LAY FACE GRAIN PERPENDICULAR TO JST/TRUSSES & STAGGER PANEL JOINTS.
6. PLY CLIPS MAY BE SUBSTITUTED FOR T & G.
STUD SCHEDULE, UNO
EXTERIOR WALL INTERIOR WALL
OPENING
WIDTH
JACK
STUDS
KING
STUDS
JACK
STUDS
KING
STUDS
1 2 1 1≤4'-0"
1 2 1 1≤5'-0"
2 2≤8'-0"
1 2 1 1≤4'-0"
2 2 1 1≤5'-0"
2 2≤8'-0"
1 2 1≤4'-0"
2 2 1≤5'-0"
2 2≤8'-0"
2 2 1≤4'-0"
2 2 1≤5'-0"
3 2 2 2≤8'-0"
2 3 2≤4'-0"
3 4 2≤5'-0"
3 5≤8'-0"5THFLR4THFLR3RDFLR2NDFLR1STFLR1
2
2
3
2
2
737 BISHOP STREET, SUITE 1860
HONOLULU, HI 96813
808-352-5299
OWNER:
523 EAST THIRD AVENUE
SPOKANE, WA 99202
P 509.323.9292
F 509.747.7115
HOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 99216TYPICAL DETAILS -
WOOD
S005
FSC PROJECT NO. 21012
PERMIT SET
5/31/2024
GL8 Mirabeau
Point, LLC
10909 E. Pierce Lane
Spokane, WA 99206
(509) 919-0901
SCALE:NTS1TYPICAL NAIL SIZE REQUIREMENTS
6010 SCALE:NTS3TYPICAL HOLE GUIDELINES AT STRUCTURAL WOOD-STUD WALLS
SCALE:NTS16TYPICAL STEEL PLATE WASHER AT WOOD-FRAMED SHEAR WALLS
SCALE:NTS5
TYPICAL MINIMUM DOUBLE TOP-PLATE LAP
AND MINIMUM SPLICE NAILING
SCALE:3" = 1'-0"6 TYPICAL WOOD STUD ATTACHMENT TO COLUMN
6010 950-0002 SCALE:3/4" = 1'-0"7 TYPICAL EXTERIOR WALL HEADER & SILL FRAMING, UNO
SCALE:NTS9TYPICAL NON-BEARING STUD WALL BRACING TO SOLID-WEB I-JOISTS
SCALE:NTS11TYPICAL SUSPENDED MECHANICAL SUPPORT @ I-JOISTS
SCALE:NTS12TYPICAL WOOD STRUCTURAL PANEL SHEAR WALL CONSTRUCTION
SCALE:NTS14TYPICAL WOOD STRUCTURAL PANEL SHEAR WALL SCHEDULE
SCALE:NTS17TYPICAL SHEAR WALL CONSTRUCTION WITH FORCE TRANSFER AROUND OPENINGS (WHERE NOTED ON PLANS)
SCALE:NTS19TYPICAL APA RATED SHEATHED ROOF DIAPHRAGM CONSTRUCTION
Revision Schedule
Number Description Date
T.O. SHTG
FLOOR SHTG
2x6 MIN BLKG @ 48" OC
MAX W/ SIMPSON LU24
HGRS EA END
I-JOISTS W/ BACKER
BLOCK @ HGRS
NON-STRUCTURAL WALL
SEE ARCH
SCALE:NTS1TYPICAL NON-STRUCTURAL WALL PARALLEL WITH JOISTS
737 BISHOP STREET, SUITE 1860
HONOLULU, HI 96813
808-352-5299
OWNER:
523 EAST THIRD AVENUE
SPOKANE, WA 99202
P 509.323.9292
F 509.747.7115
HOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 99216TYPICAL DETAILS -
WOOD
S006
FSC PROJECT NO. 21012
PERMIT SET
5/31/2024
GL8 Mirabeau
Point, LLC
10909 E. Pierce Lane
Spokane, WA 99206
(509) 919-0901
Revision Schedule
Number Description Date
T.O.B.T.O.B.T.O.B.
T.O.B.
T.O.B.T.O.B.
T.O.B.
BM SIZE TYP NO
OF BOLTS
SHEAR PL / KNIFE PL
THICKNESS CAPACITY
STIFF PL
THICKNESS
WELD
SIZE (t)
W8, W10
W12, W14
W16
W18
W21, W24
W27
W30
2
3
4
5
6
7
8
9
1/4" **
1/4" **
3/8"
3/8"
3/8"
3/8"
3/8"
3/8"
16.3 K
25.6 K
42.1 K
54.5 K
66.8 K
78.8 K
90.9 K
103.0 K
1/4"
1/4"
3/8"
3/8"
1/2"
1/2"
5/8"
5/8"
3/16" **
3/16" **
1/4"
1/4"
1/4"
1/4"
1/4"
1/4"
BOLT EDGE DISTANCE
& SPACING (TYP, UNO)
SHEAR PL OR
KNIFE PL
F.O. SUPPORT
(COLUMN OR
EMBED PL)
W BM
TYP
1/2" CLR
NOTES:
1. USE 3/4"ø A325 (HSB) SNUG-TIGHT AT BOLTED STEEL CONNECTIONS,
UNO. SEE GENERAL STRUCTURAL NOTES FOR ADDITIONAL
INFORMATION INCLUDING MATERIAL SPECIFICATIONS FOR BOLTS,
WASHERS, AND NUTS.
2. AT BEAM-COLUMN CONNECTION, USE HORIZONTAL SSL HOLES IN
SHEAR & KNIFE PLATES WHERE 'TYP NO. OF BOLTS' IS 6 OR GREATER.
PROVIDE HARDENED STEEL WASHERS. AT 5 BOLTS OR LESS, USE
EITHER STD OR HORIZONTAL SSL HOLES IN PLATES.
3. SHEAR & KNIFE PLATE CAPACITIES ARE FOR VERTICAL LOAD
APPLICATIONS AND ARE FROM AISC TABLE 10-10A, 15TH EDITION,
ALLOWABLE STRENGTH DESIGN (ASD).
4. SEE BRACED-FRAME DETAILS FOR ADDITIONAL REQUIREMENTS AT
BEAM-COLUMN CONNECTIONS.
5. USE TYPICAL NUMBER OF BOLTS WHENEVER CONNECTION
CONFIGURATION ALLOWS. COPE OR STRIP INCOMING BEAM
FLANGES AS REQUIRED.
** KNIFE PLATE THICKNESS SHALL BE 3/8" WITH 1/4" WELD SIZE AT ALL
BEAM DEPTHS, UNO.
W33 SEE NOTE 2
TYP
1 1/2"TYP1 1/2"TYP3" t
W BM
W BM
NOTES:
1. SEE TYPICAL BOLTED STEEL CONNECTION
SCHEDULE FOR ADDITIONAL INFORMATION.
2. SHEAR PLATE CONNECTION IS ACCEPTABLE AT ALL
LOCATIONS, UNO. USE KNIFE OR TEE PLATE
CONNECTION ONLY WHERE INDICATED.
3. SEE TYPICAL SKEWED SHEAR PLATE DETAIL FOR
SKEWED CONNECTIONS BETWEEN 17° AND 45°.
4. AT SHEAR PLATE CONNECTION, WALL THICKNESS OF
HSS COLUMNS SHALL BE AT LEAST 1/4" WHEN PLATE
THICKNESS IS 3/8". OTHERWISE, USE KNIFE OR
TEE-PLATE CONNECTION.
HSB (SEE SCHED)
W BM
W BM
CAP PL1/4 @
T.O. COL, UNO
TYP3"SHEAR PL
(NOTE 4)
SHEAR PLATE
(DEFAULT TYPE)
KNIFE PLATE
(ALTERNATE TYPE)
W BM
W BM
HSB (SEE SCHED)TYP3"BACK PL5/8
x COL WIDTH
x SHEAR PL
DEPTH
TEE PLATE
(ALTERNATE TYPE)
TYP BACK PL
TO COL
CL COL
& BM
t TYP3"HSB (SEE SCHED)
KNIFE PL3/8 IN
SLOTTED COL
SHEAR PL3/81/4
SHEAR PL TO
BACK PL1/4
HSS COL HSS COLCLR
1/2"
TYP
1 1/2"
CLR
1/2"
TYP
1 1/2"
HSS COL
TYP
1 1/2"
CLR
1" 1 1/2"TYP 1 1/2"TYP 1 1/2"TYPTYPICAL DECK
SUPPORT ANGLE
AS NEEDED
kW BM
CL COL &
STIFF PL
STIFF PL
EA SIDE
TYP
1 1/2"
t kW BM
CL COL &
STIFF PL
STIFF PL
EA SIDE
TYP
1 1/2"
CL COL
UNO
1'-0"kW BM
W BM SEE TYP BEAM
SPLICE DETAIL
SEE CONTINUOUS
BEAM CONDITION
NOTES:
1. BRG PLATE THICKNESS, "T" = SEE SCHEDULE @ RIGHT.
2. BRG PLATE WIDTH, "W" = GREATER OF (BEAM GAGE + 2 1/2") OR (COLUMN WIDTH + 1/2").
3. SEE TYPICAL BOLTED STEEL CONNECTION SCHEDULE FOR STIFF PLATE THICKNESS AND WELD SIZE 't'.
4. AT CONTINUOUS AND CANTILEVERED BEAMS, PROVIDE BR-2 OR BR-3 BRACE (PER TYP DETAIL) UP TO
DECK ON EITHER SIDE. NOT REQUIRED WHERE CANTILEVER DISTANCE IS LESS THAN 2x BEAM DEPTH.
END CONDITION CONTINUOUS BEAM DISCONTINUOUS / CANTILEVER BEAM
BRG PL "T"x"W"
W/ 2-3/4"⌀HSB
@ BEAM GA
BRG PL "T"x"W"
W/ 4-3/4"⌀HSB
@ BEAM GA
1/4 1/4
t
BOTTOM FLANGE BRACE
(SEE NOTE 4)
1/2"
HSS COL HSS COL HSS COL
1/2"
≤W16
≤W24
≤W33
> W33
BEAM
SIZE
BRG PLATE
THICKNESS
1/2"
5/8"
3/4"
7/8"
W MB
W MB
1/2" CLR 1 1/2" TYP
5/16
3 SIDES
(NOTE 2)
BM
1/43 SIDES
SPLICE PL3/8x6 1/2
W/ STD OR HORIZ
SSL HOLES
℄
SPLICESEE PLAN
DIMENSION
SEE PLAN
DIMENSION
HSB
(SEE SCHED)TYP3" TYP1 1/2"NOTES:
1. USE NUMBER OF BOLTS FOR SMALLER BEAM PER
TYPICAL BOLTED STEEL CONNECTION SCHEDULE.
2. ADDITIONAL FIELD WELD REQUIRED AT LATERAL
DRAG CONNECTIONS WHERE NOTED ON PLAN.
NOTES:
1. SEE TYPICAL W BEAM TO HSS COLUMN CONNECTION
DETAIL FOR ADDITIONAL INFORMATION.
2. USE EITHER KNIFE PLATE OR TEE PLATE CONNECTIONS AT
BEAMS MARKED ON PLAN WITH LATERAL DRAG SYMBOL
SHOWN BELOW, TYP UNO.
3. USE A COMBINATION OF KNIFE PLATE AND TEE PLATE
CONNECTIONS WHEN DRAG LOADS OCCUR IN BOTH
DIRECTIONS (SEE BELOW).
4. AT FLOOR BEAMS, PROVIDE PLATE-TO-BEAM WELD AFTER
CONCRETE HAS BEEN PLACED ON DECKING (AS OCCURS).
WELD APPLIES TO BEAM ON EACH SIDE OF COLUMN, UNO.W BM
W BM
KNIFE OR TEE PLATE
TEE PLHSS COL
KNIFE PLHSS COL
PLAN SYMBOL FOR
LATERAL DRAG
DRAG IN BOTH
DIRECTIONS
DRAG CONNECTION
PLAN SYMBOL
KNIFE OR
TEE PL
5/16
3 SIDES
(NOTE 4)
BM BM
TYPICAL DECK
SUPPORT ANGLE
AS NEEDED
1/4
TYP
1 1/2"
W BM kBRG PL "T"x"W"
W/ 4-3/4"⌀HSB
@ BEAM GA
HSS COL BELOW
AS OCCURS
(SEE TYP DETAIL)
STIFF PL EA SIDE
@ COLUMN CL
(USE FULL DEPTH PL
IF COL ABOVE &
BELOW)
t
HSS COL
NOTES:
1. BRG PLATE THICKNESS, "T" = 1/2" @ HSS4x4 COLS & SMALLER,
5/8" OTHERWISE.
2. BRG PLATE WIDTH, "W" = GREATER OF (BEAM GAGE + 2 1/2")
OR (COLUMN WIDTH + 1/2")
3. SEE TYPICAL BOLTED STEEL CONNECTION SCHEDULE FOR
STIFF PLATE THICKNESS AND WELD SIZE 't'.
T.O.B.
HSB PER TYP
BM-TO-BM DETAIL
SEE TYP DETAIL
FOR BM-TO-BM
SHEAR PLATE
CONN
INCOMING
W BM
STIFF PL
(SEE SCHED)
STRIP BM FLANGE
@ STIFF PL
INCOMING
W BM
W BEAM BRG ON
HSS COL (SEE
TYP DETAIL)kHSS COL
HSB (SEE SCHED)
INCOMING BM
INCOMING BM
TYP
1/2" CLR
t
SUPPORTING BM
SHEAR PL3"TYPNOTES:
1. USE SHEAR PLATE THICKNESS AND WELD SIZE 't' FOR INCOMING BEAM (SEE TYPICAL BOLTED STEEL CONNECTION SCHEDULE).
2. USE MAXIMUM NUMBER OF BOLTS IN SINGLE ROW ALLOWED BY CONFIGURATION OF EACH CONNECTION.
3. IF SCHEDULED BOLT COUNT FOR INCOMING BEAM CANNOT BE ACHIEVED IN SINGLE ROW, EXTEND SHEAR PL 3" AND ADD
SECOND ROW TO ACHIEVE BOLT COUNT. NOT REQUIRED IF ONLY ONE SCHEDULED BOLT IS DROPPED.TYP1/2" CLR 1 1/2" TYP
T.O. BEAM FLUSH
SEE NOTE 31 1/2" HSB (SEE SCHED)
HSB (SEE SCHED)3"TYP3" OCSUPPORTING BM SEE NOTE 3
INCOMING
W BM
INCOMING
W BMSEE PLANVARIESTYP3" OCSEE PLANVARIESCLR
1/2" 1 1/2" TYP
SHEAR PL 1 1/2"SHEAR PL
SEE NOTE 3
CLR
1/2"
TYP
1 1/2"t
T.O. BEAM VERTICALLY OFFSETTYP1 1/2" 5/16
1/2
F.O. SUPPORT
ANGLE
3/8" MIN BEVELED
SHEAR PL
1/4
1/2
3 " ANGLE
3/8" MIN SHEAR PL 3"17° < ANGLE ≤30°30° < ANGLE ≤45°
F.O. SUPPORT
HSS COL
3/16
3/16 MIN
2"
BRACE W/
COPED LEG
(NOTE 2)
SEE PLAN SEE PLAN
W BEAM
3/16TYP PL
BRACE
(NOTE 2)
PL1/4x5x0'-5"
EA END
(OR STIFF PL)
3/16 1½
EA END
ROOF OR
FLR DECK
HSS4x4x1/4
BTWN JSTS
TYPE BR-1 TYPE BR-2 TYPE BR-3
HSS COL
3/16EA END
STIFF PL
CONT OR
CANTILEVER
W BEAM
2
1
BRACE
(NOTE 2)
3/16
1" MAX
JST OR W BM
(REINF JST
TOP CHORD
PER TYP DTL)
HSS
L5x3½x¼
x0'-6" (LLV)
3/16
NOTES:
1. LOCATE BRACE BR-1 ONLY
WHERE SHOWN ON PLAN.
LOCATE BRACE BR-2
WHERE SHOWN ON PLAN OR
AT 8'-0" OC MAX, UNO.
2. BRACE COMPONENT SHALL
BE SIZED AS FOLLOWS:
LENGTH SIZE
≤8'-0"L3x3x1/4
>8'-0" L4x4x1/4
JST OR
W BM
ROOF OR
FLR DECK
HSS COL HSS COL
NOTES:
1. "W" = GREATER OF BEAM
OR COLUMN WIDTH
2. BOTTOM ANGLE CAN
HAVE VERT LEG TURNED
UP IF NEEDED
L3x3x1/4x LENGTH "W"
TOP & BOT
(SEE WELDS @ LEFT)HSS BEAM
HSS WINDOW SILL
TYP
TYP @ COL -
OPTIONAL
SHOP WELD
HSS BEAM
L4x3x3/8x LENGTH "W"
TOP & BOT (LLV)
1/2" CLR
1/2" CLR
TYPICAL CONDITION -
BEAMS & MULLIONS (UNO)WINDOW SILL
SEE ARCHL
737 BISHOP STREET, SUITE 1860
HONOLULU, HI 96813
808-352-5299
OWNER:
523 EAST THIRD AVENUE
SPOKANE, WA 99202
P 509.323.9292
F 509.747.7115
HOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 99216TYPICAL DETAILS -
STEEL
S007
FSC PROJECT NO. 21012
PERMIT SET
5/31/2024
GL8 Mirabeau
Point, LLC
10909 E. Pierce Lane
Spokane, WA 99206
(509) 919-0901
SCALE:NTS1TYPICAL BOLTED STEEL CONNECTION SCHEDULE
5100 SCALE:NTS3TYPICAL W-BEAM TO HSS-COLUMN CONNECTION TYPES
5100
SCALE:NTS6TYPICAL W BEAM BEARING ON HSS COLUMN
5100 100-0003 SCALE:NTS8TYPICAL BEAM SPLICE
5100 SCALE:NTS9TYPICAL W-BEAM TO HSS-COLUMN LATERAL DRAG CONNECTION
5100
SCALE:NTS11TYPICAL HSS COLUMN BEARING ON W BEAM
5100 SCALE:NTS12TYPICAL INTERSECTING BEAMS OVER HSS COLUMN
5100 SCALE:NTS13TYPICAL BEAM-TO-BEAM SHEAR PLATE CONNECTION
5100 SCALE:NTS15TYPICAL SKEWED SHEAR PLATE BETWEEN 17° & 45°
5100
SCALE:NTS16TYPICAL COLUMN & W BEAM BRACING TYPES
6010 SCALE:NTS19TYPICAL HORIZONTAL HSS MEMBER TO HSS COLUMN CONNECTION
5100
Revision Schedule
Number Description Date
STEEL DECK AND ATTACHMENT SCHEDULE
DECK TYPE GAGE I+/I-(IN4/FT)S+/S-(IN3/FT)PERP TO
DECK FLUTES
PARALLEL TO
DECK FLUTES SIDE LAP
ROOFFLOOR1 1/2" TYPE 'B'
3" TYPE 'N3'
1 1/2" TYPE 'B'
(COMPOSITE)
2" TYPE 'W2'
(COMPOSITE)
20
18
20
20
20
0.219 / 0.231
0.302 / 0.306
0.890 / 0.953
0.219 / 0.231
0.422 / 0.419
0.230 / 0.237
0.314 / 0.331
0.452 / 0.509
0.230 / 0.237
0.323 / 0.333
36/4 PATTERN
36/4 PATTERN
32/5 PATTERN
36/4 PATTERN
36/4 PATTERN
12" OC
12" OC
12" OC
12" OC
12" OC
'IP' @ 24" OC
'IP' @ 24" OC
'IP' @ 24" OC
'BP' OR 'IP'
@ 24" OC
'BP' OR 'IP'
@ 24" OC
TYPICAL MEANS OF DECK ATTACHMENT
STEEL FRAMING:1/2"Ø ARC SPOT WELDS
3/8"x1" LONG ARC SEAM WELDS
(MINIMUM EFFECTIVE FUSION AREAS)
WOOD FRAMING:1/4"x2 1/2" SIMPSON SDS SCREWS
(SEE NOTE 5)
'BP' = BUTTON PUNCH
'IP' = INTERLOCK PUNCH (VERCO VSC2 OR EQUIV)
NOTES:
1. SCHEDULE INDICATES MINIMUM REQUIREMENTS, UNO ON PLANS.
2. VERIFY DECK FINISH WITH ARCHL DRAWINGS.
3. ACOUSTICAL DECK REQUIRED WHERE NOTED ON PLANS OR ARCHL DRAWINGS.
4. WHERE PROVIDED, WELDED SHEAR STUDS CAN REPLACE A DECK WELD ON A ONE-TO-ONE BASIS.
5. WHERE DECK ATTACHES TO WOOD FRAMING, PROVIDE BUILDING PAPER BETWEEN DECK AND
WOOD. UNLESS SCREWS HAVE SELF-DRILLING CAPABILITIES, PROVIDE 17/64"Ø PRE-DRILLED
HOLES THROUGH DECK ONLY.
36/4
36/7
32/5
36/4
TYPE 'B' DECK
TYPE 'N3' DECK
TYPE 'W2' DECK
DENOTES ARC SPOT WELD
DENOTES ARC SEAM WELD
EFFECTIVE SECTION PROPS DECK ATTACHMENT, UNO
GENERAL NOTE:
BUTT JOINTS SHALL ONLY BE USED WHERE LAP JOINTS
CANNOT BE ACHIEVED.
1 2
4
3 STEEL
DECK
WF OR
OWSJ
WF OPEN WEB
JOIST
LAP JOINT BUTT JOINT BUTT JOINT
OVER OWSJ
KEY NOTES:
PROVIDE 2" MINIMUM END LAP LOCATED ENTIRELY OVER
SUPPORTING MEMBER.
1
2
3
PROVIDE 2" MINIMUM END BEARING IN ALL CASES.
END GAP AT BUTT JOINTS SHALL BE MINIMIZED TO ALLOW
2" MINIMUM BEARING FOR EACH DECK PIECE.
PROVIDE CONT 6"-WIDE BUTT STRIP TO MATCH DECK GAGE
(GALV) W/ #12 SCREWS @ 12" OC EACH SIDE OF JOINT.
4
KEY NOTES:
PROVIDE CONT 16 GAGE CLOSURE STRIP WHERE LOW DECK FLUTES
CANNOT ATTACH DIRECTLY TO SUPPORTING MEMBER.
1
ATTACH CLOSURE TO SUPPORTING MEMBER PER TYPICAL DECK
SCHEDULE.
2
ATTACH DECK TO CLOSURE W/ #12 SCREWS @ 12" OC.
ATTACHMENT CAN BE MADE THRU LOW FLUTE OR WEB.
3
PERIMETER
SUPPORT
INTERIOR
SUPPORT
2 3 2 3
1
STEEL
DECK
1
WF
1 1/2" MIN 3" MAX
GENERAL NOTE:
DETAIL APPLIES ONLY WHERE LOW DECK FLUTE CANNOT BE
ATTACHED DIRECTLY TO SUPPORT.NOTE:
THIS DETAIL APPLIES
TO A SINGLE ISOLATED
PENETRATION. FOR
GROUPS OF SMALL
PENETRATIONS, SEE
TYPICAL DETAILS FOR
MEDIUM AND LARGE
OPENINGS.
PENETRATION SIZE OF 6" TO 12"
(NOT REQ'D AT PENETRATIONS < 6")
MIN 16 GA GALV
SHEET EXTENDED
6" BEYOND OPNG
ON ALL SIDES
#12 SCREWS @
6" OC AROUND
PERIMETER
737 BISHOP STREET, SUITE 1860
HONOLULU, HI 96813
808-352-5299
OWNER:
523 EAST THIRD AVENUE
SPOKANE, WA 99202
P 509.323.9292
F 509.747.7115
HOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 99216TYPICAL DETAILS -
STEEL
S008
FSC PROJECT NO. 21012
PERMIT SET
5/31/2024
GL8 Mirabeau
Point, LLC
10909 E. Pierce Lane
Spokane, WA 99206
(509) 919-0901
SCALE:NTS1TYPICAL MINIMUM REQUIREMENTS FOR STEEL ROOF AND FLOOR DECK
SCALE:NTS3TYPICAL DECK END JOINTS OVER SUPPORTS
SCALE:NTS4TYPICAL DECK CLOSURE PARALLEL TO FLUTES
SCALE:NTS5TYPICAL SMALL PENETRATION AT ROOF DECK
Revision Schedule
Number Description Date
-SS--SS--SS-
-SS-
1
A
A
B C D
E F G H J K
L
M N P
22.1
3
3.1
4
5
6 6
6.1
7 7
8 8
8.1
9 9
C.1 L.1
65'-1 1/2"
30'-6 5/8"5'-10 1/4"28'-8 5/8"131'-9 1/8"30'-0"13'-4 7/8"5'-9 7/8"9'-3"15'-0 5/8"3'-11 1/4"15'-2 3/4"8'-8 7/8"6'-1 1/4"4'-7 3/8"19'-7 1/4"6'-0"55'-11 3/8"19'-0 7/8"19'-0 3/4"19'-1"19'-0 7/8"19'-0 3/4"14'-11"19'-1 1/2"10'-9"14'-11 1/4"19'-1 1/2"19'-9 1/8"54'-3 1/2"23'-11 5/8"6'-1 1/4"24'-2 5/8"27'-9 7/8"Q
249'-11"
68'-9 1/2"
10 10
11 28'-0"0"11'-0 5/8"8'-6"8'-3 1/4"WS326
WS326
WS26 TYP @
CORRIDOR
WALLS, UNO
WS326
WS326
WS326 TYP @
DEMISING WALLS
WS226 TYP @
EXT WALLS
UNO
WS326
WS326
WS326
WS326
WS326
WS226
WS226
WS226
WS28
WS28
WS28
WS326
W8x10W8x10W8x10W8x10W8x10W8x10W8x10W8x10 W8x10
W8x10
W8x10
W8x10W8x10W8x13W8x10W8x10
NOTE:SEE DETAIL
X/SXXX FOR W8
STEEL HEADERS
P1-4P1-4P1-4
P1-4
P2-6P2-423.5K T35.1K C23.5K T35.1K CP2-4
P1-6P2-4
P1-6P2-4
P2-4P1-4P2-4 3.3K T20.3K C3.3K T20.3K CP1-6P1-4P1-4P1-48.5K T22.3K C8.5K T22.3K CP2-3P2-4P2-4 5.6K T13.8K C5.6K T13.8K C15.6K T19.3K C15.6K T19.3K CP1-4P1-4P1-4P1-4P1-4P2-3-5/8
P2-3-5/8
P2-3
P2-3
P1-6
P1-6
FTAO
STEEL MOMENT FRAME
P1-4P1-43-2x8 3-2x8 3-2x8 2.8K T18.8K C2.8K T18.8K C12.3K T14.9K C21.2K T21.2K C21.2K T21.2K C4.1K T22.8K C4.1K T22.8K C10.2K T25.4K C10.2K T25.4K C10.9K T29.5K C10.9K T29.5K C16.8K T29.6K C16.8K T29.6K C8.2K T30.3K C8.2K T30.3K C9.9K T30.4K C9.9K T30.4K C2.4K T17.4K C2.4K T17.4K CHDU14-SDS2.5H D U14 -SD S2.5HDU8-SDS2.5SDS2.5HDU8-14.0K T11.6K C14.0K T11.6K C19.7K T22.5K C19.7K T22.5K C14.6K T16.9K C14.6K T16.9K C9.8K T13.6K C9.8K T13.6K C10.1K T12.7K C10.1K T12.7K C7.3K T12.2K C7.3K T12.2K CP1-610.1K T12.7K C8.1K T12.3K C1.7K T4.2K C1.7K T4.2K C4.7K T10.6K C6.8K T23.0K C4.7K T10.6K CP1-61.7K T4.2K C1.7K T4.2K CP1-62.5K T4.4K C2.5K T4.4K C6.8K T23.0K C10.0K T28.0K C6.7K T11.7K C6.7K T11.7K C5.1K T26.2K C5.1K T26.2K C1. SEE S002 FOR CONTINUOUS TIE DOWN SYSTEM NOTES.
2. ALL 1ST FLOOR LEVEL EXTERIOR WALLS TO BE SHEATHED WITH 5/8"
FRT SHEATHING, INCLUDING DOUBLE SIDED SHEAR WALLS.
3. ALL 2ND FLOOR LEVEL AND ABOVE EXTERIOR SHEAR WALLS TO BE
SHEATHED WITH 5/8" FRT SHEATHING, SECTIONS OF EXTERIOR
WALLS NOT DESIGNATED AS SHEAR WALLS MAY BE SHEATHED WITH
DENSGLASS SHEATHING MEETING THE FIRE ASSEMBLY
REQUIREMENTS.
4. ALIGN STUDS ABOVE WITH STUDS BELOW AT ALL WALLS BEARING ON
WALLS THAT DON'T HAVE INTERVENING RIMBOARD (EXTERIOR
WALLS AND SHAFT WALLS).
OVERALL PLAN NOTESSTRUCTURAL WALL SCHEDULE, UNO
NOTES:
1. ALL EXTERIOR WALLS TO BE FRAMED WITH FRT STUDS,
PLATES, HEADERS, AND SHEATHING.
2. SEE TYPICAL DETAIL FOR KING AND JACK STUD
REQUIREMENTS.
3. SEE SHEARWALL SCHEDULE FOR ADDITIONAL
REQUIREMENTS.
2x4 STUDS @ 16" OCWS24
2x6 STUDS @ 16" OC
2x8 STUDS @ 16" OC
2-2x4 STUDS @ 16" OC
2-2x6 STUDS @ 16" OC
3-2x6 STUDS @ 16" OC
WS26
WS28
WS224
WS226
WS326
MIN HEADER SCHEDULE, UNO
OPENING
WIDTH
1st FLR -4th FLREXTERIOR
WALL
CORRIDOR
WALL
DEMISING
WALL
5th FLR≤4'-0"2-2x6 2-2x6 2-2x8
≤5'-0"2-2x6 2-2x6
≤8'-0"2-2x8
≤4'-0"2-2x6 2-2x6 2-2x8
3-2x6 3-2x8
2-2x8
≤5'-0"
≤8'-0"
737 BISHOP STREET, SUITE 1860
HONOLULU, HI 96813
808-352-5299
OWNER:
523 EAST THIRD AVENUE
SPOKANE, WA 99202
P 509.323.9292
F 509.747.7115
HOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 99216OVERALL FLOOR /
FOUNDATION PLAN &
1ST FLOOR WALLS
S101
FSC PROJECT NO. 21012
PERMIT SET
5/31/2024
GL8 Mirabeau
Point, LLC
10909 E. Pierce Lane
Spokane, WA 99206
(509) 919-0901
NORTHSCALE:3/32" = 1'-0"
OVERALL FLOOR / FOUNDATION PLAN & 1ST FLOOR WALLS
STRUCTURAL COLUMN SCHEDULE
MARK COL SIZE REMARKS
C444 HSS4x4x1/4
C554 HSS5x5x1/4
C556 HSS5x5x3/8
C558 HSS5x5x1/2
C664 HSS6x6x1/4
C666 HSS6x6x3/8
C756 HSS7X5X3/8
C758 HSS7x5x1/2
C8810 HSS8X8X5/8
W12x35 W12x35
Revision Schedule
Number Description Date
1
A
A
B C D
E F G H J K
L
M N P
1.1
22.1
3
3.1
4
5
6 6
6.1
7 7
8 8
8.1
9 9
C.1 L.1 Q
10 10
11
249'-11"133'-6"55'-11 3/8"19'-0 7/8"19'-0 3/4"19'-1"19'-0 7/8"19'-0 3/4"14'-11"19'-1 1/2"10'-9"14'-11 1/4"19'-1 1/2"19'-9 1/8"25'-8 7/8"13'-4 7/8"5'-9 7/8"9'-3"15'-0 5/8"3'-11 1/4"15'-2 3/4"8'-8 7/8"6'-1 1/4"4'-7 3/8"19'-7 1/4"6'-0"65'-1 1/2"
30'-6 5/8"5'-10 1/4"28'-8 5/8"27'-9 7/8"WS26
WS26 TYP @
EXT WALLS
UNO
WS26
WS26 TYP @
DEMISING WALLS,
UNO
WS226
WS226
WS26 TYP @ CORRIDOR WALLS UNO4'-3 1/8"WS226
OR WS28WS26 TYP @ CORRIDOR WALLS UNOWS224
WS224
LVL3 1/2x11 7/8
P1-4
P1-6P1-4 P1-49.3K T16.1K C9.3K T16.1K CP1-6
P1-6
P1-412.5K T20.1K C16.9K T21.4K CP1-4
P1-6
P1-6P2-342.5K T45.1K C42.5K T45.1K CP1-3P1-312.1K T19.1K C11.1K T18.8K C12.1K T19.1K C11.1K T18.8K CP2-341.4K T44.2K C41.4K T44.2K CP1-4 11.3K T18.9K C11.3K T18.9K CP1-3P1-4P1-4 11.2K T20.3K C11.2K T20.3K CP1-4
P1-6P1-62.5K T18.2K C2.5K T18.2K CP1-3 11.4K T20.1K C11.4K T20.1K CP1-4P1-3 11.4K T20.1K C11.4K T20.1K CP1-4
P1-4P1-4P1-311.4K T20.1K C11.4K T20.1K CP1-3 2.5K T17.2K C2.5K T17.2K CP1-311.4K T20.1K C11.4K T20.1K CP1-3 2.5K T17.2K C2.5K T17.2K CP1-4
P1-3
P1-6P1-3
P1-3P1-41.0K T18.1K C1.0K T18.1K CP1-611.4K T16.6K C11.4K T16.6K CP1-3P1-4P1-3 10.2K T16.1K C10.2K T16.1K CP1-3 10.2K T16.1K C10.2K T16.1K CP1-4
P1-310.2K T16.1K C10.2K T16.1K CP1-310.2K T16.1K C10.2K T16.1K CP1-4P1-4P1-4P1-6P1-4P1-4P1-412.5K T20.1K C16.9K T21.4K CP1-6
P1-4P1-4P1-312.3K T14.9K C12.3K T14.9K C11.7K T14.7K C11.7K T14.7K C11.8K T14.7K C11.8K T14.7K CP1-4 13.1K T16.5K C13.1K T16.5K C10.4K T16.0K C10.4K T16.0K C7.7K T10.5K C7.7K T10.5K C3.2K T17.6K C3.2K T17.6K C7.9K T17.7K C7.9K T17.7K C2.3K T18.2K C2.3K T18.2K C1.5K T6.5K C1.5K T6.5K C9.0K T11.1K C9.0K T11.1K C6.6K T10.5K C6.6K T10.5K CSHADED AREA INDICATES
2x6 FLAT BLOCKING REQ'D
W/ E.N. AT ALL PANEL EDGES
SHADED AREA INDICATES
2x6 FLAT BLOCKING REQ'D
W/ E.N. AT ALL PANEL EDGES5.1K T13.K C5.1K T13.K C3.1K T9.9K C3.1K T9.9K C4.2K T8.6K C2.8K T7.9K C2.8K T7.9K C5.3K T8.2K C5.3K T8.2K C12.3K T14.1K C12.3K T14.1K C9.8K T11.6K C9.8K T11.6K C10.6K T13.3K C10.6K T13.3K C9.8K T11.6K C9.8K T11.6K C3.3K T5.6K C3.3K T5.6K C5.7K T8.8K C5.7K T8.8K C5.7K T8.8K C5.7K T8.8K C5.7K T8.8K C5.7K T8.8K C5.7K T8.8K C5.7K T8.8K C5.7K T8.8K C5.7K T8.8K C6.0K T8.9K C6.0K T8.9K C5.3K T8.2K C5.3K T8.2K C6.6K T8.5K C6.6K T8.5K C4.9K T8.1K C4.9K T8.1K C1. SEE S002 FOR CONTINUOUS TIE DOWN SYSTEM NOTES.
2. ALL 1ST FLOOR LEVEL EXTERIOR WALLS TO BE SHEATHED WITH 5/8"
FRT SHEATHING, INCLUDING DOUBLE SIDED SHEAR WALLS.
3. ALL 2ND FLOOR LEVEL AND ABOVE EXTERIOR SHEAR WALLS TO BE
SHEATHED WITH 5/8" FRT SHEATHING, SECTIONS OF EXTERIOR
WALLS NOT DESIGNATED AS SHEAR WALLS MAY BE SHEATHED WITH
DENSGLASS SHEATHING MEETING THE FIRE ASSEMBLY
REQUIREMENTS.
4. ALIGN STUDS ABOVE WITH STUDS BELOW AT ALL WALLS BEARING ON
WALLS THAT DON'T HAVE INTERVENING RIMBOARD (EXTERIOR
WALLS AND SHAFT WALLS).
OVERALL PLAN NOTESSTRUCTURAL WALL SCHEDULE, UNO
NOTES:
1. ALL EXTERIOR WALLS TO BE FRAMED WITH FRT STUDS,
PLATES, HEADERS, AND SHEATHING.
2. SEE TYPICAL DETAIL FOR KING AND JACK STUD
REQUIREMENTS.
3. SEE SHEARWALL SCHEDULE FOR ADDITIONAL
REQUIREMENTS.
2x4 STUDS @ 16" OCWS24
2x6 STUDS @ 16" OC
2x8 STUDS @ 16" OC
2-2x4 STUDS @ 16" OC
2-2x6 STUDS @ 16" OC
3-2x6 STUDS @ 16" OC
WS26
WS28
WS224
WS226
WS326
MIN HEADER SCHEDULE, UNO
OPENING
WIDTH
1st FLR -4th FLREXTERIOR
WALL
CORRIDOR
WALL
DEMISING
WALL
5th FLR≤4'-0"2-2x6 2-2x6 2-2x8
≤5'-0"2-2x6 2-2x6
≤8'-0"2-2x8
≤4'-0"2-2x6 2-2x6 2-2x8
3-2x6 3-2x8
2-2x8
≤5'-0"
≤8'-0"
737 BISHOP STREET, SUITE 1860
HONOLULU, HI 96813
808-352-5299
OWNER:
523 EAST THIRD AVENUE
SPOKANE, WA 99202
P 509.323.9292
F 509.747.7115
HOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 99216OVERALL FLOOR 2
FRAMING PLAN & 2ND
FLOOR WALLS
S102
FSC PROJECT NO. 21012
PERMIT SET
5/31/2024
GL8 Mirabeau
Point, LLC
10909 E. Pierce Lane
Spokane, WA 99206
(509) 919-0901
STRUCTURAL COLUMN SCHEDULE
MARK COL SIZE REMARKS
C444 HSS4x4x1/4
C554 HSS5x5x1/4
C556 HSS5x5x3/8
C558 HSS5x5x1/2
C664 HSS6x6x1/4
C666 HSS6x6x3/8
C756 HSS7X5X3/8
C758 HSS7x5x1/2
C8810 HSS8X8X5/8
W12x35 W12x35
NORTHSCALE:3/32" = 1'-0"
OVERALL FLOOR 2 FRAMING PLAN & 2ND FLOOR WALLS
Revision Schedule
Number Description Date
1
A
A
B C D
E F G H J K
L
M N P
1.1
22.1
3
3.1
4
5
6 6
6.1
7 7
8 8
8.1
9 9
C.1 L.1 Q
10 10
249'-11"133'-6"55'-11 3/8"19'-0 7/8"19'-0 3/4"19'-1"19'-0 7/8"19'-0 3/4"14'-11"19'-1 1/2"10'-9"14'-11 1/4"19'-1 1/2"19'-9 1/8"25'-8 7/8"13'-4 7/8"5'-9 7/8"9'-3"15'-0 5/8"3'-11 1/4"15'-2 3/4"8'-8 7/8"6'-1 1/4"4'-7 3/8"19'-7 1/4"6'-0"65'-1 1/2"
30'-6 5/8"5'-10 1/4"28'-8 5/8"27'-9 7/8"4'-2 5/8"4'-3 1/8"WS224 @ 3RD FLOOR
WS24 @ 4TH & 5TH FLOOR
WS26 TYP @ CORRIDOR WALLS
WS26
WS26 TYP @
EXT WALLS
WS26
WS226 TYP @ 3RD
FLOOR DEMISING
WALLS,
WS26 TYP @ 4TH &
5TH FLOOR
DEMISING WALLS
WS26
WS26
5
S130
P1-6
P1-6P1-4 P1-64.8K T10.2K C4.8K T10.2K CP1-6
P1-6P1-4P1-4
P1-6
P1-6P2-426.6K T28.7K C26.6K T28.7K CP1-4P1-47.5K T12.7K C6.8K T12.5K C7.5K T12.7K C6.8K T12.5K CP2-425.8K T28.2K C25.8K T28.2K CP1-6 7.0K T12.6K C7.0K T12.6K CP1-4P1-3P1-6 9.4K T16.3K C9.4K T16.3K CP1-6
P1-6P1-32.5K T14.4K C2.5K T14.4K CP1-4 7.5K T13.9K C7.5K T13.9K CP1-6P1-4 7.5K T13.9K C7.5K T13.9K CP1-4
P1-6P1-4P1-47.5K T13.9K C7.5K T13.9K CP1-4 0.3K T11.2K C0.3K T11.2K CP1-47.5K T13.9K C7.5K T13.9K CP1-4 0.3K T11.2K C0.3K T11.2K CP1-4
P1-6P1-4P1-4P1-66.1K T9.9K C6.1K T9.9K CP1-4P1-4P1-4 5.3K T9.6K C5.3K T9.6K CP1-4 5.3K T9.6K C5.3K T9.6K CP1-6
P1-45.3K T9.6K C5.3K T9.6K CP1-45.3K T9.6K C5.3K T9.6K CP1-6P1-4P1-4P1-6P1-4P1-6P1-6P1-4
P1-4
P1-44.1K T7.2K C4.1K T7.2K C5.9K T7.6K C5.9K T7.6K C7.0K T9.4K C7.0K T9.4K C7.1K T9.4K C7.1K T9.4K C7.4K T9.5K C7.4K T9.5K CP1-4 7.9K T10.5K C7.9K T10.5K C4.8K T10.2K C4.8K T10.2K C5.7K T7.5K C5.7K T7.5K C5.0K T7.2K C5.0K T7.2K C0.6K T11.2K C0.6K T11.2K C4.0K T11.3K C4.0K T11.3K C1.4K T7.6K C1.4K T7.6K C2.2K T5.4K C1.0K T5.0K C1.0K T5.0K C2.9K T5.2K C2.9K T5.2K C3.3K T5.6K C3.3K T5.6K C5.7K T8.8K C5.7K T8.8K C5.7K T8.8K C5.7K T8.8K C5.7K T8.8K C5.7K T8.8K C5.7K T8.8K C5.7K T8.8K C5.7K T8.8K C5.7K T8.8K C6.0K T8.9K C6.0K T8.9K C7.9K T9.3K C7.9K T9.3K C5.4K T6.8K C5.4K T6.8K C6.6K T8.8K C6.6K T8.8K C5.4K T6.8K C5.4K T6.8K C3.8K T5.4K C3.8K T5.4K C2.6K T5.1K C2.6K T5.1K CSTRUCTURAL WALL SCHEDULE, UNO
NOTES:
1. ALL EXTERIOR WALLS TO BE FRAMED WITH FRT STUDS,
PLATES, HEADERS, AND SHEATHING.
2. SEE TYPICAL DETAIL FOR KING AND JACK STUD
REQUIREMENTS.
3. SEE SHEARWALL SCHEDULE FOR ADDITIONAL
REQUIREMENTS.
2x4 STUDS @ 16" OCWS24
2x6 STUDS @ 16" OC
2x8 STUDS @ 16" OC
2-2x4 STUDS @ 16" OC
2-2x6 STUDS @ 16" OC
3-2x6 STUDS @ 16" OC
WS26
WS28
WS224
WS226
WS326
MIN HEADER SCHEDULE, UNO
OPENING
WIDTH
1st FLR -4th FLREXTERIOR
WALL
CORRIDOR
WALL
DEMISING
WALL
5th FLR≤4'-0"2-2x6 2-2x6 2-2x8
≤5'-0"2-2x6 2-2x6
≤8'-0"2-2x8
≤4'-0"2-2x6 2-2x6 2-2x8
3-2x6 3-2x8
2-2x8
≤5'-0"
≤8'-0"
1. SEE S002 FOR CONTINUOUS TIE DOWN SYSTEM NOTES.
2. ALL 1ST FLOOR LEVEL EXTERIOR WALLS TO BE SHEATHED WITH 5/8"
FRT SHEATHING, INCLUDING DOUBLE SIDED SHEAR WALLS.
3. ALL 2ND FLOOR LEVEL AND ABOVE EXTERIOR SHEAR WALLS TO BE
SHEATHED WITH 5/8" FRT SHEATHING, SECTIONS OF EXTERIOR
WALLS NOT DESIGNATED AS SHEAR WALLS MAY BE SHEATHED WITH
DENSGLASS SHEATHING MEETING THE FIRE ASSEMBLY
REQUIREMENTS.
4. ALIGN STUDS ABOVE WITH STUDS BELOW AT ALL WALLS BEARING ON
WALLS THAT DON'T HAVE INTERVENING RIMBOARD (EXTERIOR
WALLS AND SHAFT WALLS).
OVERALL PLAN NOTES
737 BISHOP STREET, SUITE 1860
HONOLULU, HI 96813
808-352-5299
OWNER:
523 EAST THIRD AVENUE
SPOKANE, WA 99202
P 509.323.9292
F 509.747.7115
HOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 99216OVERALL FLOORS 3
FRAMING PLANS & 3RD
FLOOR WALLS
S103
FSC PROJECT NO. 21012
PERMIT SET
5/31/2024
GL8 Mirabeau
Point, LLC
10909 E. Pierce Lane
Spokane, WA 99206
(509) 919-0901
NORTHSCALE:3/32" = 1'-0"
OVERALL FLOOR 3 FRAMING PLAN & 3RD FLOOR WALLS
Revision Schedule
Number Description Date
STRUCTURAL WALL SCHEDULE, UNO
NOTES:
1. ALL EXTERIOR WALLS TO BE FRAMED WITH FRT STUDS,
PLATES, HEADERS, AND SHEATHING.
2. SEE TYPICAL DETAIL FOR KING AND JACK STUD
REQUIREMENTS.
3. SEE SHEARWALL SCHEDULE FOR ADDITIONAL
REQUIREMENTS.
2x4 STUDS @ 16" OCWS24
2x6 STUDS @ 16" OC
2x8 STUDS @ 16" OC
2-2x4 STUDS @ 16" OC
2-2x6 STUDS @ 16" OC
3-2x6 STUDS @ 16" OC
WS26
WS28
WS224
WS226
WS326
MIN HEADER SCHEDULE, UNO
OPENING
WIDTH
1st FLR -4th FLREXTERIOR
WALL
CORRIDOR
WALL
DEMISING
WALL
5th FLR≤4'-0"2-2x6 2-2x6 2-2x8
≤5'-0"2-2x6 2-2x6
≤8'-0"2-2x8
≤4'-0"2-2x6 2-2x6 2-2x8
3-2x6 3-2x8
2-2x8
≤5'-0"
≤8'-0"
1. SEE S002 FOR CONTINUOUS TIE DOWN SYSTEM NOTES.
2. ALL 1ST FLOOR LEVEL EXTERIOR WALLS TO BE SHEATHED WITH 5/8"
FRT SHEATHING, INCLUDING DOUBLE SIDED SHEAR WALLS.
3. ALL 2ND FLOOR LEVEL AND ABOVE EXTERIOR SHEAR WALLS TO BE
SHEATHED WITH 5/8" FRT SHEATHING, SECTIONS OF EXTERIOR
WALLS NOT DESIGNATED AS SHEAR WALLS MAY BE SHEATHED WITH
DENSGLASS SHEATHING MEETING THE FIRE ASSEMBLY
REQUIREMENTS.
4. ALIGN STUDS ABOVE WITH STUDS BELOW AT ALL WALLS BEARING ON
WALLS THAT DON'T HAVE INTERVENING RIMBOARD (EXTERIOR
WALLS AND SHAFT WALLS).
OVERALL PLAN NOTES
1
A
A
B C D
E F G H J K
L
M N P
1.1
22.1
3
3.1
4
5
6 6
6.1
7 7
8 8
8.1
9 9
C.1 L.1 Q
10 10
11
P1-6
P1-6P1-6 P1-61.4K T5.6K C1.4K T5.6K CP1-6
P1-6P1-6P1-6
P1-6
P1-6P2-614.3K T15.7K C14.3K T15.7K CP1-4P1-44.0K T7.4K C3.5K T7.3K C4.0K T7.4K C3.5K T7.3K CP2-613.9K T15.4K C13.9K T15.4K CP1-6 3.7K T7.4K C3.7K T7.4K CP1-4P1-3P1-6 4.6K T9.2K C4.6K T9.2K CP1-6
P1-6P1-40.5K T8.2K C0.5K T8.2K CP1-4 4.7K T8.8K C4.7K T8.8K CP1-6P1-4 4.7K T8.8K C4.7K T8.8K CP1-6
P1-61.3K T3.7K C1.3K T3.7K CP1-6P1-44.7K T8.8K C4.7K T8.8K CP1-6
P1-44.7K T8.8K C4.7K T8.8K CP1-6
P1-6
P1-6
P1-6P1-4
P1-6P1-6P1-4
P1-61.9K T4.4K C1.9K T4.4K CP1-4P1-6P1-4 1.4K T4.2K C1.4K T4.2K CP1-4 1.4K T4.2K C1.4K T4.2K CP1-6
P1-41.4K T4.2K C1.4K T4.2K CP1-41.4K T4.2K C1.4K T4.2K CP1-6P1-6P1-6P1-6P1-61.7K T3.9K C1.7K T3.9K C2.8K T4.1K C2.8K T4.1K C3.4K T5.1K C3.4K T5.1K C3.4K T5.1K C3.4K T5.1K C3.7K T5.2K C3.7K T5.2K CP1-6 4.0K T5.7K C4.0K T5.7K C2.7K T5.6K C2.7K T5.6K C2.8K T4.1K C2.8K T4.1K C2.4K T3.9K C2.4K T3.9K C1.4K T6.2K C1.4K T6.2K C0.7K T2.8K C4.3K T5.3K C4.3K T5.3K C1.8K T2.9K C1.8K T2.9K C3.5K T5.0K C3.5K T5.0K C1.8K T2.9K C1.8K T2.9K C1.4K T2.9K C1.4K T2.9K C1.4K T2.9K C1.4K T2.9K C1.4K T2.9K C1.4K T2.9K C1.4K T2.9K C1.4K T2.9K C1.4K T2.9K C1.4K T2.9K C1.5K T2.9K C1.5K T2.9K C1.7K T2.8K C1.7K T2.8K C0.8K T2.7K C0.8K T2.7K C1.4K T2.9K C1.4K T2.9K C1.0K T2.7K C1.0K T2.7K C737 BISHOP STREET, SUITE 1860
HONOLULU, HI 96813
808-352-5299
OWNER:
523 EAST THIRD AVENUE
SPOKANE, WA 99202
P 509.323.9292
F 509.747.7115
HOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 99216OVERALL 4TH FLOOR
FRAMING PLANS & 4TH
FLOOR WALLS
S104
FSC PROJECT NO. 21012
PERMIT SET
5/31/2024
GL8 Mirabeau
Point, LLC
10909 E. Pierce Lane
Spokane, WA 99206
(509) 919-0901
NORTHSCALE:3/32" = 1'-0"
OVERALL FLOOR 4 FRAMING PLAN & 4TH FLOOR WALLS
Revision Schedule
Number Description Date
STRUCTURAL WALL SCHEDULE, UNO
NOTES:
1. ALL EXTERIOR WALLS TO BE FRAMED WITH FRT STUDS,
PLATES, HEADERS, AND SHEATHING.
2. SEE TYPICAL DETAIL FOR KING AND JACK STUD
REQUIREMENTS.
3. SEE SHEARWALL SCHEDULE FOR ADDITIONAL
REQUIREMENTS.
2x4 STUDS @ 16" OCWS24
2x6 STUDS @ 16" OC
2x8 STUDS @ 16" OC
2-2x4 STUDS @ 16" OC
2-2x6 STUDS @ 16" OC
3-2x6 STUDS @ 16" OC
WS26
WS28
WS224
WS226
WS326
MIN HEADER SCHEDULE, UNO
OPENING
WIDTH
1st FLR -4th FLREXTERIOR
WALL
CORRIDOR
WALL
DEMISING
WALL
5th FLR≤4'-0"2-2x6 2-2x6 2-2x8
≤5'-0"2-2x6 2-2x6
≤8'-0"2-2x8
≤4'-0"2-2x6 2-2x6 2-2x8
3-2x6 3-2x8
2-2x8
≤5'-0"
≤8'-0"
1. SEE S002 FOR CONTINUOUS TIE DOWN SYSTEM NOTES.
2. ALL 1ST FLOOR LEVEL EXTERIOR WALLS TO BE SHEATHED WITH 5/8"
FRT SHEATHING, INCLUDING DOUBLE SIDED SHEAR WALLS.
3. ALL 2ND FLOOR LEVEL AND ABOVE EXTERIOR SHEAR WALLS TO BE
SHEATHED WITH 5/8" FRT SHEATHING, SECTIONS OF EXTERIOR
WALLS NOT DESIGNATED AS SHEAR WALLS MAY BE SHEATHED WITH
DENSGLASS SHEATHING MEETING THE FIRE ASSEMBLY
REQUIREMENTS.
4. ALIGN STUDS ABOVE WITH STUDS BELOW AT ALL WALLS BEARING ON
WALLS THAT DON'T HAVE INTERVENING RIMBOARD (EXTERIOR
WALLS AND SHAFT WALLS).
OVERALL PLAN NOTES
1
A
A
B C D
E F G H J K
L
M N P
1.1
22.1
3
3.1
4
5
6 6
6.1
7 7
8 8
8.1
9 9
C.1 L.1 Q
10 10
11
P1-6
P1-6P1-6 P1-61.0K T2.8K C1.0K T2.8K CP1-6
P1-6P1-6P1-6
P1-6
P1-6P1-45.3K T6.1K C5.3K T6.1K CP1-6P1-61.6K T3.2K C1.3K T3.2K C1.6K T3.2K C1.3K T3.2K CP1-45.1K T5.9K C5.1K T5.9K CP1-6 1.5K T3.2K C1.5K T3.2K CP1-6P1-6P1-6 1.1K T3.6K C1.1K T3.6K CP1-6
P1-6P1-6
P1-4 2.9K T4.8K C2.9K T4.8K CP1-6P1-4 2.9K T4.8K C2.9K T4.8K CP1-6
P1-6P1-6P1-42.9K T4.8K C2.9K T4.8K CP1-6
P1-42.9K T4.8K C2.9K T4.8K CP1-6
P1-6
P1-6
P1-6P1-6
P1-6P1-6P1-6
P1-6P1-6P1-6WS226
WS226
WS226
(GRID D TO
GRID J)
WS226 WS226
3-2x8 3-2x8
3-2x83-2x8 0.8K T1.6K C0.8K T1.6K C0.9K T2.0K C0.9K T2.0K C0.9K T2.0K C1.0K T2.0K C1.0K T2.0K CP1-6 1.3K T2.2K C1.3K T2.2K C0.7K T1.6K C0.7K T1.6K C0.6K T1.5K C0.6K T1.5K C1.8K T2.5K C1.8K T2.5K C1.3K T2.3K C1.3K T2.3K C737 BISHOP STREET, SUITE 1860
HONOLULU, HI 96813
808-352-5299
OWNER:
523 EAST THIRD AVENUE
SPOKANE, WA 99202
P 509.323.9292
F 509.747.7115
HOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 99216OVERALL 5TH FLOOR
FRAMING PLANS & 5TH
FLOOR WALLS
S105
FSC PROJECT NO. 21012
PERMIT SET
5/31/2024
GL8 Mirabeau
Point, LLC
10909 E. Pierce Lane
Spokane, WA 99206
(509) 919-0901
NORTHSCALE:3/32" = 1'-0"
OVERALL FLOOR 5 FRAMING PLAN & 5TH FLOOR WALLS
Revision Schedule
Number Description Date
1
A
A
B C D
E F G H J K M N P
1.1
2.1
3
4
5
6 6
7 7
8 8
8.1
9 9
Q
10 10
249'-11"4'-3 1/8"133'-6"65'-1 1/2"
30'-6 5/8"5'-10 1/4"28'-8 5/8"
75'-0 1/4"19'-0 3/4"19'-1"19'-0 7/8"19'-0 3/4"14'-11"29'-10 1/2"14'-11 1/4"19'-1 1/2"19'-9 1/8"25'-8 7/8"13'-4 7/8"15'-0 7/8"15'-0 5/8"3'-11 1/4"23'-11 5/8"6'-1 1/4"4'-7 3/8"19'-7 1/4"6'-0"60'-3 1/2"23'-11 5/8"6'-1 1/4"24'-2 5/8"6'-0"TYP 5/8" APA RATED SHTGTYP 5/8" APA RATED SHTGT.O.P.
65'-10"54'-3 1/2"T.O.P.
65'-10"T.O.P.
63'-10"
T.O.P.
63'-10"
T.O.P.
63'-10"
T.O.P.
63'-10"
T.O.P.
65'-10"
T.O.P.
69'-10"
T.O.P.
65'-10"
T.O.P.
63'-10"
T.O.P.
63'-10"
T.O.P.
65'-10"
T.O.P.
63'-10"
T.O.P.
69'-10"T.O.P.
63'-10"
T.O.P.
65'-10"
T.O.P.
63'-10"
T.O.P.
65'-10"
ERV-01
6,500#
CU-02
1,500#
CU-03
1,500#
STRUCTURAL WALL SCHEDULE, UNO
NOTES:
1. ALL EXTERIOR WALLS TO BE FRAMED WITH FRT STUDS,
PLATES, HEADERS, AND SHEATHING.
2. SEE TYPICAL DETAIL FOR KING AND JACK STUD
REQUIREMENTS.
3. SEE SHEARWALL SCHEDULE FOR ADDITIONAL
REQUIREMENTS.
2x4 STUDS @ 16" OCWS24
2x6 STUDS @ 16" OC
2x8 STUDS @ 16" OC
2-2x4 STUDS @ 16" OC
2-2x6 STUDS @ 16" OC
3-2x6 STUDS @ 16" OC
WS26
WS28
WS224
WS226
WS326
MIN HEADER SCHEDULE, UNO
OPENING
WIDTH
1st FLR -4th FLREXTERIOR
WALL
CORRIDOR
WALL
DEMISING
WALL
5th FLR≤4'-0"2-2x6 2-2x6 2-2x8
≤5'-0"2-2x6 2-2x6
≤8'-0"2-2x8
≤4'-0"2-2x6 2-2x6 2-2x8
3-2x6 3-2x8
2-2x8
≤5'-0"
≤8'-0"
1. SEE S002 FOR CONTINUOUS TIE DOWN SYSTEM NOTES.
2. ALL 1ST FLOOR LEVEL EXTERIOR WALLS TO BE SHEATHED WITH 5/8"
FRT SHEATHING, INCLUDING DOUBLE SIDED SHEAR WALLS.
3. ALL 2ND FLOOR LEVEL AND ABOVE EXTERIOR SHEAR WALLS TO BE
SHEATHED WITH 5/8" FRT SHEATHING, SECTIONS OF EXTERIOR
WALLS NOT DESIGNATED AS SHEAR WALLS MAY BE SHEATHED WITH
DENSGLASS SHEATHING MEETING THE FIRE ASSEMBLY
REQUIREMENTS.
4. ALIGN STUDS ABOVE WITH STUDS BELOW AT ALL WALLS BEARING ON
WALLS THAT DON'T HAVE INTERVENING RIMBOARD (EXTERIOR
WALLS AND SHAFT WALLS).
OVERALL PLAN NOTES
737 BISHOP STREET, SUITE 1860
HONOLULU, HI 96813
808-352-5299
OWNER:
523 EAST THIRD AVENUE
SPOKANE, WA 99202
P 509.323.9292
F 509.747.7115
HOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 99216OVERALL ROOF
FRAMING PLAN &
PARAPET WALLS
S106
FSC PROJECT NO. 21012
PERMIT SET
5/31/2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce Lane
Spokane, WA 99206
(509) 919-0901
NORTHSCALE:3/32" = 1'-0"
OVERALL ROOF FRAMING PLAN & PARAPET WALLS
Revision Schedule
Number Description Date
-SS-
-SS--SS--SS-1 1
A
A
B C D
E
2
2.1
3
3.1
4
5
6 6
6.1
7 7
8 8
8.1
9 9
C.1
65'-1 1/2"
30'-6 5/8"5'-10 1/4"28'-8 5/8"131'-9 1/8"30'-0"13'-4 7/8"5'-9 7/8"9'-3"15'-0 5/8"3'-11 1/4"15'-2 3/4"8'-8 7/8"6'-1 1/4"4'-7 3/8"19'-7 1/4"W12x35W12x35W12x35W12x35W12x35W12x35C556C554C554C558C556C556C558C558C556C554C558C756C758C554C556C554C556C558C554C556C556C556C758C556C556C556C554C758C554F40
F30
F30
F50
F40
F40
F50F50F40F30
F50
F50
F50F40
F40
F40
F80
F50
F50
F30
F40
F40
F40
F60
F40F50 F40 F30 F50
F40
F60F60F60F60F60
F602x8 @ 16" OCPOOL BY
OTHERS7"10'-5 5/8"8'-6"10'-5 3/8"5 1/4"4'-2"
11 7/8"
12'-10 3/8"11'-1"11'-1"11'-1"12'-10 3/8"
11 7/8"11'-0 5/8"8'-6"8'-3 1/4"C5545 1/2"4 5/8"F50
F50
6'-0 1/8"5'-9"1'-11 3/4"T.O.PIER
5'-10" TYPC554C554
T.O.F.
-5'-0"
T.O.F.
-3'-6"C5542 3/4"9"3'-11 1/4"10'-0 1/2"F.O.C.F.O.C.F.O.C.
F.O.C.
F.O.C.F.O.C.F.O.C.C8810C554F508'-11"1'-9 3/4"7'-5 1/4"9'-2 3/4"10'-0 1/2"2'-1 7/8"3'-11 1/8"
7'-1"
4'-4"
6'-4"
11'-2 3/4"5 1/4"2'-6"
5 1/4"
T.O.P.
-3'-6"
1
S301
__________
SW8CF24
CF24 SW8
1
S301
__________
TS18TS18
TS18
CF24SW8
1
S301
__________
TS18
TS18
TS18
10
S301
__________
T.O.F.
-2'-0"TS18TS188
S301
__________
TYP (UNO) @
THICKENED
SLAB
8
S301
__________CF24SW8 CF24SW8
1
S301
__________CF18SW10
2
S301
__________
1
S301
__________CF24SW8
SW14
2
S301
__________CF18SW10
TS18F30C756T.O.F.
-2'-0"
TYP @
PERIM, UNO
T.O.F.
-2'-0"
TYP @
PERIM, UNO
__________
S004
13 TYP @ INTR
COL, UNO
T.O.F.
-1'-0"
TYP @ INTR
COL, UNO
3
S301
__________
TYP @ PERIM
COLS, UNO
3
S301
__________
TYP @ PERIM
COLS, UNO C554C554C554C554C554C5548'-11 3/4"9'-3 1/2"1'-0"(-1'-0")
HSS4x4x1/4
16
S301
__________
T.O.F.
-2'-8"
18
S301
__________
1. SEE S0-SERIES FOR GENERAL STRUCTURAL NOTES, ABBREVIATIONS,
LEGEND & TYPICAL DETAILS.
2. COORDINATE & VERIFY ALL DIMENSIONS WITH ARCHL DRAWINGS.
3. ALL DIMENSION LINES ARE CENTERLINE OF COL, FACE OF STUD, OR
FACE OF CONCRETE, UNO.
4. LOCATE FOOTINGS ON CENTERLINE OF WALLS, COLUMNS, ETC UNO.
5. SEE GEOTECHNICAL REPORT FOR RECOMMENDED SUBGRADE
PREPARATION BELOW FOOTINGS AND SLABS ON GRADE.
6. PIPES MAY PASS THROUGH STRUCTURAL CONCRETE IN SLEEVES BUT
SHALL NOT BE EMBEDDED THEREIN - SEE TYPICAL DETAIL.
7. PROVIDE 3/4" CHAMFER AT ALL EXPOSED CONCRETE CORNERS.
8. SEE ARCHL DRAWINGS FOR EXTERIOR WALKS, CURBS, ETC.
9. REFER TO ALL ARCHITECTURAL, ELECTRICAL & MECHANICAL PLANS
FOR PROPER COORDINATION WITH ALL OTHER TRADES.
FLOOR/FOUNDATION PLAN NOTES
737 BISHOP STREET, SUITE 1860
HONOLULU, HI 96813
808-352-5299
OWNER:
523 EAST THIRD AVENUE
SPOKANE, WA 99202
P 509.323.9292
F 509.747.7115
HOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 99216FLOOR/FOUNDATION
PLAN - WEST WING
S121
FSC PROJECT NO. 21012
PERMIT SET
5/31/2024
GL8 Mirabeau
Point, LLC
10909 E. Pierce Lane
Spokane, WA 99206
(509) 919-0901
NORTHSCALE:1/8" = 1'-0"
FLOOR / FOUNDATION PLAN - WEST WING
STRUCTURAL FOOTING SCHEDULE
MARK FOOTING SIZE REINFORCEMENT
CF18 CONT 1'-6" x 12" DP 2-#4 CONT
CF24 CONT 2'-0" x 12" DP 3-#4 CONT
F30 3'-0" SQ x12" DP 4-#4 EW BOT
F40 4'-0" SQ x12" DP 5-#4 EW BOT
F50 5'-0" SQ x15" DP 6-#5 EW BOT
F60 6'-0" SQ x16" DP 7-#5 EW BOT
F80 8'-0" SQ x 18" DP 9-#6 EW BOT
STRUCTURAL COLUMN SCHEDULE
MARK COL SIZE REMARKS
C444 HSS4x4x1/4
C554 HSS5x5x1/4
C556 HSS5x5x3/8
C558 HSS5x5x1/2
C664 HSS6x6x1/4
C666 HSS6x6x3/8
C756 HSS7X5X3/8
C758 HSS7x5x1/2
C8810 HSS8X8X5/8
W12x35 W12x35
FOUNDATION STEM WALLS
MARK STEM WALL REF. DETAIL, UNO
SW8 8" CONC
SW10 10" CONC
SW12 12" CONC
SW14 14" CONC
Revision Schedule
Number Description Date
-SS-
-SS--SS--SS-E
E
F
F
G
G
H
H
J
J
K
K
L
M
M
N
N
P
P
4
5
6 6
7 7
8 8
9 9
C.1
L.1
L.1
Q
Q
10 1060'-3 1/2"23'-11 5/8"6'-1 1/4"24'-2 5/8"6'-0"C556C556C758C554C758C554C558C556C556C756C556C556C556C556C756C556C558C558C556C556C554C758C554C666C666C664C664C664C664C666C666C556C556F40
F40
F60
F50
F60
F50
F60
F50
F40
F50
F40
F40F40
F40
F50
F40
F50F50
F40 F30 F50
F40 F50
F50 F40
F40 F40
F40 F50
F50 F40
F40
TYP 4" CONC SLAB ON GRADE
W/ FIBER REINFORCEMENT
T.O. SLAB ELEV = 0'-0"
TYP @
EXTR, UNO
T.O.F.
-1'-0"
TYP @ INTR
COL, UNO
T.O.F.
-2'-0"
TYP @
PERIM, UNO
7 1/2"6 3/8"C558C554C554T.O.F.
-5'-0"
T.O.F.
-3'-6"C5546'-3" 6'-7"F.O.C.19'-0 7/8"19'-0 3/4"19'-1"19'-0 7/8"19'-0 3/4"14'-11"19'-1 1/2"10'-9"14'-11 1/4"19'-1 1/2"19'-9 1/8"
193'-11 5/8"
4'-2 5/8"5 1/4"2'-0"5 1/4"C558C558C558C558T.O.F.
-2'-0"
F40 F40
5'-0 5/8"7'-5 1/4"9'-2 3/4"C444C4448'-1"5 3/8"5 7/8"3"1'-0"5 7/8"5 1/4"F30
F30
2'-11 7/8"
2'-1 7/8"3'-11 1/8"6'-4"4'-7"4'-0"3'-3"7 1/2"5 7/8"5 3/8"4'-0"2'-0"4 3/4"5 1/4"11 3/8"3'-6 3/8"3'-6 1/2"C558T.O.P.
-3'-6"
F30
F30C444C4448'-1"
1'-6 1/2"
11'-0"TS18TS24TS24
TS18TS18TS24TS24TS24TS18TS18TS24
TS24CF24
8
S301
__________
SW8 SW8
1
S301
__________
CF24
SW8 CF24
1
S301
__________CF24SW8CF24SW8
1
S301
__________
8
S301
__________
TYP (UNO) @
THICKENED SLAB
CF24 SW8
1
S301
__________
3
S301
__________TYP @ PERIM
COLS, UNO
__________
S004
13TYP @ INTR
COL, UNO
CF18 SW8
10
S301
__________
10
S301
__________
1
S301
__________
SW8CF24
CF24 SW8
1
S301
__________
TS18 TS18F30
11'-0"
5"TYP @
PERIM, UNO
T.O.F.
-2'-0"
3
S301
__________
TYP @ PERIM
COLS, UNOC554C554C554C554C554C5548'-11 3/4"9'-3 1/2"1'-0"(-1'-0")
HSS4x4x1/4
16
S301
__________
18
S301
__________
1. SEE S0-SERIES FOR GENERAL STRUCTURAL NOTES, ABBREVIATIONS,
LEGEND & TYPICAL DETAILS.
2. COORDINATE & VERIFY ALL DIMENSIONS WITH ARCHL DRAWINGS.
3. ALL DIMENSION LINES ARE CENTERLINE OF COL, FACE OF STUD, OR
FACE OF CONCRETE, UNO.
4. LOCATE FOOTINGS ON CENTERLINE OF WALLS, COLUMNS, ETC UNO.
5. SEE GEOTECHNICAL REPORT FOR RECOMMENDED SUBGRADE
PREPARATION BELOW FOOTINGS AND SLABS ON GRADE.
6. PIPES MAY PASS THROUGH STRUCTURAL CONCRETE IN SLEEVES BUT
SHALL NOT BE EMBEDDED THEREIN - SEE TYPICAL DETAIL.
7. PROVIDE 3/4" CHAMFER AT ALL EXPOSED CONCRETE CORNERS.
8. SEE ARCHL DRAWINGS FOR EXTERIOR WALKS, CURBS, ETC.
9. REFER TO ALL ARCHITECTURAL, ELECTRICAL & MECHANICAL PLANS
FOR PROPER COORDINATION WITH ALL OTHER TRADES.
FLOOR/FOUNDATION PLAN NOTES
737 BISHOP STREET, SUITE 1860
HONOLULU, HI 96813
808-352-5299
OWNER:
523 EAST THIRD AVENUE
SPOKANE, WA 99202
P 509.323.9292
F 509.747.7115
HOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 99216FLOOR/FOUNDATION
PLAN - EAST WING
S122
FSC PROJECT NO. 21012
PERMIT SET
5/31/2024
GL8 Mirabeau
Point, LLC
10909 E. Pierce Lane
Spokane, WA 99206
(509) 919-0901
NORTHSCALE:1/8" = 1'-0"
FLOOR / FOUNDATION PLAN - EAST WING
STRUCTURAL FOOTING SCHEDULE
MARK FOOTING SIZE REINFORCEMENT
CF18 CONT 1'-6" x 12" DP 2-#4 CONT
CF24 CONT 2'-0" x 12" DP 3-#4 CONT
F30 3'-0" SQ x12" DP 4-#4 EW BOT
F40 4'-0" SQ x12" DP 5-#4 EW BOT
F50 5'-0" SQ x15" DP 6-#5 EW BOT
F60 6'-0" SQ x16" DP 7-#5 EW BOT
F80 8'-0" SQ x 18" DP 9-#6 EW BOT
STRUCTURAL COLUMN SCHEDULE
MARK COL SIZE REMARKS
C444 HSS4x4x1/4
C554 HSS5x5x1/4
C556 HSS5x5x3/8
C558 HSS5x5x1/2
C664 HSS6x6x1/4
C666 HSS6x6x3/8
C756 HSS7X5X3/8
C758 HSS7x5x1/2
C8810 HSS8X8X5/8
W12x35 W12x35
FOUNDATION STEM WALLS
MARK STEM WALL REF. DETAIL, UNO
SW8 8" CONC
SW10 10" CONC
SW12 12" CONC
SW14 14" CONC
Revision Schedule
Number Description Date
F G H
9 9
10 10
11
19'-1"19'-0 7/8"28'-0"C556C756C556C556C556C556C756C556C554C554F40
F50
F40
F40F40
F40
F50
F40
F50F50
7'-7 5/8" 6'-4 3/8" 6'-4 1/4" 7'-11 3/4"
7 1/2"
6"6"
6 3/8"6"6'-9" 7'-1"5'-0 5/8"F50F50C554C55411 3/8"3'-6 3/8"3'-6 1/2"SW8
1
S301
__________
F G H
9 9
10 10
11 11
19'-1"19'-0 7/8"W16x26W16x26W18x50
W10x12W16x40W16x40W10x12W16x31
SLOPE1/2 : 121½"x20GA TYPE 'B'
STL ROOF DECK GALV
2'-11"6'-4 3/8" 6'-4 3/8" 6'-4 3/8" 6'-4 1/4" 6'-4 1/4" 6'-4 1/4"
2'-11 1/8"W14x26W14x26W14x26W14x26W14x26W14x26W14x26W18x35 (CONT)
(16'-10 5/8")FJ6FJ6FJ6FJ611
S402
__________
13
S402
__________7'-0"7'-0"7'-0"7'-0"15
S402
__________
15
S402
__________W14x26W14x26W14x26W14x26W14x26W14x26W14x261. SEE S0-SERIES FOR GENERAL STRUCTURAL NOTES, ABBREVIATIONS,
LEGEND & TYPICAL DETAILS.
2. COORDINATE & VERIFY ALL DIMENSIONS WITH ARCHL DRAWINGS.
3. ALL DIMENSION LINES ARE CENTERLINE OF COL, FACE OF STUD, OR
FACE OF CONCRETE, UNO.
4. LOCATE FOOTINGS ON CENTERLINE OF WALLS, COLUMNS, ETC UNO.
5. SEE GEOTECHNICAL REPORT FOR RECOMMENDED SUBGRADE
PREPARATION BELOW FOOTINGS AND SLABS ON GRADE.
6. PIPES MAY PASS THROUGH STRUCTURAL CONCRETE IN SLEEVES BUT
SHALL NOT BE EMBEDDED THEREIN - SEE TYPICAL DETAIL.
7. PROVIDE 3/4" CHAMFER AT ALL EXPOSED CONCRETE CORNERS.
8. SEE ARCHL DRAWINGS FOR EXTERIOR WALKS, CURBS, ETC.
9. REFER TO ALL ARCHITECTURAL, ELECTRICAL & MECHANICAL PLANS
FOR PROPER COORDINATION WITH ALL OTHER TRADES.
FLOOR/FOUNDATION PLAN NOTES
737 BISHOP STREET, SUITE 1860
HONOLULU, HI 96813
808-352-5299
OWNER:
523 EAST THIRD AVENUE
SPOKANE, WA 99202
P 509.323.9292
F 509.747.7115
HOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 99216PORTE COCHERE
FOUNDATION & ROOF
FRAMING PLANS
S123
FSC PROJECT NO. 21012
PERMIT SET
5/31/2024
GL8 Mirabeau
Point, LLC
10909 E. Pierce Lane
Spokane, WA 99206
(509) 919-0901
NORTHSCALE:1/8" = 1'-0"
PORTE COCHERE FOUNDATION PLAN
NORTHSCALE:1/8" = 1'-0"
PORTE COCHERE ROOF FRAMING PLAN
STRUCTURAL FOOTING SCHEDULE
MARK FOOTING SIZE REINFORCEMENT
CF18 CONT 1'-6" x 12" DP 2-#4 CONT
CF24 CONT 2'-0" x 12" DP 3-#4 CONT
F30 3'-0" SQ x12" DP 4-#4 EW BOT
F40 4'-0" SQ x12" DP 5-#4 EW BOT
F50 5'-0" SQ x15" DP 6-#5 EW BOT
F60 6'-0" SQ x16" DP 7-#5 EW BOT
F80 8'-0" SQ x 18" DP 9-#6 EW BOT
STRUCTURAL COLUMN SCHEDULE
MARK COL SIZE REMARKS
C444 HSS4x4x1/4
C554 HSS5x5x1/4
C556 HSS5x5x3/8
C558 HSS5x5x1/2
C664 HSS6x6x1/4
C666 HSS6x6x3/8
C756 HSS7X5X3/8
C758 HSS7x5x1/2
C8810 HSS8X8X5/8
W12x35 W12x35
Revision Schedule
Number Description Date
1
A
A
B C D
E
1.1
2
2.1
3
3.1
4
5
6 6
6.1
7 7
8 8
8.1
9 9
C.1
65'-1 1/2"
30'-6 5/8"5'-10 1/4"28'-8 5/8"C558FJ1FJ1C558W18X40
W21x68W21x68W21X55W21X55W16x26
W21x68
W24x76 LVL 5 1/4x11 7/8W16x36
W16x31W10x19
W21x68
W21x68
W21x68
W16x26C558C558C558
W14x26FJ31½"x20GA TYPE 'B'STL ROOF DECK GALVW30x108W12x16W24x55W24x55W12x26
W12x35 W12x35
W18X40
W30x90W21x44
W12x22
W12x35 W12x35
W24x84
W30x90W12x16W24x55W12x16W16x31W16x31
W14x22W16x31W24x76W18X40
127'-6"25'-8 7/8"13'-4 7/8"5'-9 7/8"9'-3"15'-0 5/8"3'-11 1/4"15'-2 3/4"8'-8 7/8"6'-1 1/4"4'-7 3/8"19'-7 1/4"4'-3 1/8"27'-9 7/8"75'-0 1/4"
55'-11 3/8"19'-0 7/8"
FJ4
FJ4
FJ4
FJ4
FJ4
FJ4
FJ4
FJ6
FJ4
FJ5
FJ6
FJ6
FJ6 FJ6FJ6FJ6
FJ6
FJ1 FJ5FJ6FJ6(13'-6 7/8")W16x316
S401
__________
11'-0" 3'-10"6'-5 3/4"11'-0"
W18x35
W18x35C554C554C554C554C554C554
LVL 5 1/4x11 7/8
HSS4x4x1/4
(16'-0")
(9'-0")
3
S401
__________
6
S401
__________
6
S401
__________
4
S401
__________
3
S401
__________
1
S401
__________3
S401
__________
SHADED AREA INDICATES
2x6 FLAT BLOCKING REQ'D
W/ E.N. AT ALL PANEL EDGES
(16'-0")
(9'-0")
HSS5x5x1/4
1. SEE S0-SERIES SHEETS FOR GENERAL STRUCTURAL NOTES,
ABBREVIATIONS, LEGEND & TYPICAL DETAILS.
2. COORDINATE AND VERIFY ALL DIMENSIONS WITH ARCHITECTURAL
DRAWINGS.
3. REFER TO ALL ARCHITECTURAL, ELECTRICAL, & MECHANICAL
DRAWINGS FOR PROPER COORDINATION WITH OTHER TRADES.
4. COORDINATE FLOOR JOIST LOCATIONS WITH MECHANICAL &
PLUMBING PENETRATIONS.
FLOOR FRAMING PLAN NOTESFLOOR JOIST SCHEDULE, UNO
2x8 @ 16" OCFJ1
2-2x8 @ 16" OCFJ2
FJ3
FJ4 11 7/8" RED-I45 @ 19.2" OC
2-LVL1 3/4x7 1/4 @ 16" OC
FJ6
FJ5 11 7/8" RED-I45 @ 16" OC
11 7/8" RED-I65 @ 16" OC
737 BISHOP STREET, SUITE 1860
HONOLULU, HI 96813
808-352-5299
OWNER:
523 EAST THIRD AVENUE
SPOKANE, WA 99202
P 509.323.9292
F 509.747.7115
HOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 99216FLOOR 2 FRAMING
PLAN - WEST WING
S124
FSC PROJECT NO. 21012
PERMIT SET
5/31/2024
GL8 Mirabeau
Point, LLC
10909 E. Pierce Lane
Spokane, WA 99206
(509) 919-0901
NORTHSCALE:1/8" = 1'-0"
FLOOR 2 FRAMING PLAN - WEST WING
STRUCTURAL COLUMN SCHEDULE
MARK COL SIZE REMARKS
C444 HSS4x4x1/4
C554 HSS5x5x1/4
C556 HSS5x5x3/8
C558 HSS5x5x1/2
C664 HSS6x6x1/4
C666 HSS6x6x3/8
C756 HSS7X5X3/8
C758 HSS7x5x1/2
C8810 HSS8X8X5/8
W12x35 W12x35
Revision Schedule
Number Description Date
E F G H J K
L
M N P
4
5
6 6
7 7
8 8
9 9
C.1 L.1 Q
10 10C558C558C558C558C558C558C558W21x68W21x68W21x68W21x68LVL 5 1/4x11 7/8
W21x68W21x68W21X55W12x16W12x16W18X40
W16x26W16x26W18x50W21x68W21x68W21x68W16x26
W16x31 W12x16 W21X55 W12x16W10x19
W16x26 W16x26 W16x26 W18x35
W10x12W16x40W16x40W10x12W21X55W16x31
W21X55
__________
S130
1
19'-0 7/8"19'-0 3/4"19'-1"19'-0 7/8"19'-0 3/4"14'-11"19'-1 1/2"10'-9"14'-11 1/4"19'-1 1/2"19'-9 1/8"
193'-11 5/8"FJ6FJ5FJ1
FJ6FJ6FJ6FJ6FJ6FJ6FJ6FJ6FJ4FJ4FJ6FJ4FJ5
FJ4FJ4FJ6FJ6FJ6FJ6SEE 2/S123 FOR PORTE
COCHERE FRAMING
CANOPY
BELOW
6
S401
__________
6
S401
__________6
S401
__________
5
S130
3
S130 C558W21x68
W14x22C8X11.5
C8X11.5
W8X13C8X11.5
C8X11.5
4 1/2"4 1/2"
11'-0"11'-0"
4 1/2"4 1/2"
11'-0"11'-0"
W18x35W18x35W18x35C554C554C554C554C554C554
LVL 5 1/4x11 7/8
HSS4x4x1/4
(16'-0")
(9'-0")
3
S401
__________3
S401
__________
3
S401
__________
1
S401
__________
4
S401
__________
4
S401
__________
__________
S601
A
__________
S601
A
SHADED AREA INDICATES
2x6 FLAT BLOCKING REQ'D
W/ E.N. AT ALL PANEL EDGES
(16'-0")
(9'-0")
HSS5x5x1/4
1. SEE S0-SERIES SHEETS FOR GENERAL STRUCTURAL NOTES,
ABBREVIATIONS, LEGEND & TYPICAL DETAILS.
2. COORDINATE AND VERIFY ALL DIMENSIONS WITH ARCHITECTURAL
DRAWINGS.
3. REFER TO ALL ARCHITECTURAL, ELECTRICAL, & MECHANICAL
DRAWINGS FOR PROPER COORDINATION WITH OTHER TRADES.
4. COORDINATE FLOOR JOIST LOCATIONS WITH MECHANICAL &
PLUMBING PENETRATIONS.
FLOOR FRAMING PLAN NOTESFLOOR JOIST SCHEDULE, UNO
2x8 @ 16" OCFJ1
2-2x8 @ 16" OCFJ2
FJ3
FJ4 11 7/8" RED-I45 @ 19.2" OC
2-LVL1 3/4x7 1/4 @ 16" OC
FJ6
FJ5 11 7/8" RED-I45 @ 16" OC
11 7/8" RED-I65 @ 16" OC
737 BISHOP STREET, SUITE 1860
HONOLULU, HI 96813
808-352-5299
OWNER:
523 EAST THIRD AVENUE
SPOKANE, WA 99202
P 509.323.9292
F 509.747.7115
HOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 99216FLOOR 2 FRAMING
PLAN - EAST WING
S125
FSC PROJECT NO. 21012
PERMIT SET
5/31/2024
GL8 Mirabeau
Point, LLC
10909 E. Pierce Lane
Spokane, WA 99206
(509) 919-0901
NORTHSCALE:1/8" = 1'-0"
FLOOR 2 FRAMING PLAN - EAST WING
STRUCTURAL COLUMN SCHEDULE
MARK COL SIZE REMARKS
C444 HSS4x4x1/4
C554 HSS5x5x1/4
C556 HSS5x5x3/8
C558 HSS5x5x1/2
C664 HSS6x6x1/4
C666 HSS6x6x3/8
C756 HSS7X5X3/8
C758 HSS7x5x1/2
C8810 HSS8X8X5/8
W12x35 W12x35
Revision Schedule
Number Description Date
1
A
A
B C D
E
1.1
2
2.1
3
3.1
4
5
6 6
6.1
7 7
8 8
8.1
9 9
C.1
65'-1 1/2"
30'-6 5/8"5'-10 1/4"28'-8 5/8"127'-6"25'-8 7/8"13'-4 7/8"5'-9 7/8"9'-3"15'-0 5/8"3'-11 1/4"15'-2 3/4"8'-8 7/8"6'-1 1/4"4'-7 3/8"19'-7 1/4"4'-3 1/8"75'-0 1/4"
55'-11 3/8"19'-0 7/8"27'-9 7/8"FJ1FJ1FJ3FJ4
FJ4
FJ4
FJ4
FJ4
FJ4
FJ4
FJ6
FJ4
FJ5
FJ6
FJ6
FJ6 FJ6FJ6FJ6
FJ6
FJ1 FJ5FJ6FJ6LVL 5 1/4x11 7/8
LVL 3 1/2x11 7/8
LVL 5 1/4x11 7/8__________
S601
B
__________
S601
B
W16x36 C554C554C554C554C554C554HSS4x4x1/4
(26'-0")
(38'-0")
(49'-0")
(53'-2")
(57'-11)
1
S401
__________
3
S401
__________
4
S401
__________
6
S401
__________
4
S401
__________
3
S401
__________
4
S401
__________
3
S401
__________
1
S401
__________
HSS5x5x1/4
(26'-0")
(38'-0")
(49'-0")
(57'-11)
1. SEE S0-SERIES SHEETS FOR GENERAL STRUCTURAL NOTES,
ABBREVIATIONS, LEGEND & TYPICAL DETAILS.
2. COORDINATE AND VERIFY ALL DIMENSIONS WITH ARCHITECTURAL
DRAWINGS.
3. REFER TO ALL ARCHITECTURAL, ELECTRICAL, & MECHANICAL
DRAWINGS FOR PROPER COORDINATION WITH OTHER TRADES.
4. COORDINATE FLOOR JOIST LOCATIONS WITH MECHANICAL &
PLUMBING PENETRATIONS.
FLOOR FRAMING PLAN NOTESFLOOR JOIST SCHEDULE, UNO
2x8 @ 16" OCFJ1
2-2x8 @ 16" OCFJ2
FJ3
FJ4 11 7/8" RED-I45 @ 19.2" OC
2-LVL1 3/4x7 1/4 @ 16" OC
FJ6
FJ5 11 7/8" RED-I45 @ 16" OC
11 7/8" RED-I65 @ 16" OC
737 BISHOP STREET, SUITE 1860
HONOLULU, HI 96813
808-352-5299
OWNER:
523 EAST THIRD AVENUE
SPOKANE, WA 99202
P 509.323.9292
F 509.747.7115
HOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 99216FLOORS 3 THRU 5
FRAMING PLANS - WEST
WING
S126
FSC PROJECT NO. 21012
PERMIT SET
5/31/2024
GL8 Mirabeau
Point, LLC
10909 E. Pierce Lane
Spokane, WA 99206
(509) 919-0901
NORTHSCALE:1/8" = 1'-0"
FLOORS 3 THRU 5 FRAMING PLANS - WEST WING
Revision Schedule
Number Description Date
E F G H J K
L
M N P
4
5 5
6 6
7 7
8 8
9 9
C.1 L.1 Q
10 10
19'-0 7/8"19'-0 3/4"19'-1"19'-0 7/8"19'-0 3/4"14'-11"19'-1 1/2"10'-9"14'-11 1/4"19'-1 1/2"19'-9 1/8"
193'-11 5/8"
4'-2 5/8"FJ6FJ1 FJ5FJ1
FJ6FJ6FJ6FJ6FJ6FJ6FJ6FJ6FJ4FJ4FJ6FJ4FJ5
FJ4FJ4FJ6FJ6FJ6FJ6LVL 5 1/4x11 7/8
__________
S601
A
__________
S601
A
__________
S601
C __________
S601
CC554C554C554C554C554C554
HSS4x4x1/4
(26'-0")
(38'-0")
(49'-0")
(53'-2")
(57'-11)
3
S401
__________
4
S401
__________
4
S401
__________4
S401
__________
4
S401
__________
1
S401
__________
3
S401
__________
3
S401
__________
HSS5x5x1/4
(26'-0")
(38'-0")
(49'-0")
(57'-11)
1. SEE S0-SERIES SHEETS FOR GENERAL STRUCTURAL NOTES,
ABBREVIATIONS, LEGEND & TYPICAL DETAILS.
2. COORDINATE AND VERIFY ALL DIMENSIONS WITH ARCHITECTURAL
DRAWINGS.
3. REFER TO ALL ARCHITECTURAL, ELECTRICAL, & MECHANICAL
DRAWINGS FOR PROPER COORDINATION WITH OTHER TRADES.
4. COORDINATE FLOOR JOIST LOCATIONS WITH MECHANICAL &
PLUMBING PENETRATIONS.
FLOOR FRAMING PLAN NOTESFLOOR JOIST SCHEDULE, UNO
2x8 @ 16" OCFJ1
2-2x8 @ 16" OCFJ2
FJ3
FJ4 11 7/8" RED-I45 @ 19.2" OC
2-LVL1 3/4x7 1/4 @ 16" OC
FJ6
FJ5 11 7/8" RED-I45 @ 16" OC
11 7/8" RED-I65 @ 16" OC
737 BISHOP STREET, SUITE 1860
HONOLULU, HI 96813
808-352-5299
OWNER:
523 EAST THIRD AVENUE
SPOKANE, WA 99202
P 509.323.9292
F 509.747.7115
HOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 99216FLOORS 3 THRU 5
FRAMING PLANS - EAST
WING
S127
FSC PROJECT NO. 21012
PERMIT SET
5/31/2024
GL8 Mirabeau
Point, LLC
10909 E. Pierce Lane
Spokane, WA 99206
(509) 919-0901
NORTHSCALE:1/8" = 1'-0"
FLOORS 3 THRU 5 FRAMING PLANS - EAST WING
Revision Schedule
Number Description Date
1
A
A
B C D
E
1.1
2
2.1
3
3.1
4
5
6 6
6.1
7 7
8 8
8.1
9 9
65'-1 1/2"
30'-6 5/8"5'-10 1/4"28'-8 5/8"
TYP 5/8" APA RATED SHTG
T.O.P.
65'-10"
6
S501
__________
6
S501
__________
6
S501
__________
6
S501
__________
6
S501
__________
6
S501
__________
6
S501
__________
6
S501
__________127'-6"4'-3 1/8"75'-0 1/4"27'-9 7/8"25'-8 7/8"13'-4 7/8"5'-9 7/8"9'-3"15'-0 5/8"3'-11 1/4"15'-2 3/4"8'-8 7/8"6'-1 1/4"4'-7 3/8"19'-7 1/4"W14x22
RJ2
RJ2
RJ2
RJ2
RJ2
RJ2
RJ2
RJ2
RJ2
RJ2
RJ2RJ2RJ4
RJ2RJ4
RJ2
RJ2
RJ2RJ2RJ1RJ2RJ2RJ2RJ1RJ1RJ6
RJ6
RJ3
RJ2
RJ5
RJ5
RJ5
RJ5
CU-05
150#
CU-04
150#
19
S501
__________
16
S501
__________
16
S501
__________
16
S501
__________
SIM
17
S501
__________
HSS8x4x1/4
HSS8x4x1/4
(62'-10")
(62'-10")
HSS8x4x1/4
(62'-10")
W8x18, 2 PLCS
(62'-10"), SEE NOTE 6
11
S502
__________
13
S502
__________
1. SEE S0-SERIES SHEETS FOR GENERAL STRUCTURAL NOTES,
ABBREVIATIONS, LEGEND & TYPICAL DETAILS.
2. COORDINATE AND VERIFY ALL DIMENSIONS WITH ARCHITECTURAL
DRAWINGS.
3. REFER TO ALL ARCHITECTURAL, ELECTRICAL, & MECHANICAL
DRAWINGS FOR PROPER COORDINATION WITH OTHER TRADES.
4. VERIFY MECHANICAL UNIT LOCATIONS. IF UNITS ARE NOT PLACED
WHERE INDICATED ON THIS PLAN CONTACT THE STURTURAL ENGINEER
PRIOR TO TRUSS FABRICATION.
5. COORDINATE ATTIC VENTING REQUIREMENTS WITH ARCHITECTURAL
DRAWINGS.
6. ELEVATOR HOIST BEAMS HAVE BEEN DESIGNED TO SUPPORT 7.5 KIP
LOADS AT ANY LOCATION ALONG BEAM. SEE DETAILS FOR HOIST
BEAM & RAIL COLUMN CONNECTIONS.
ROOF FRAMING PLAN NOTES
1
A
A
D
E
2
3
4
5
6
7
8
9
10
DR-5DR-5DR-2DR-5DR-4DR-5DR-1DR-1DR-4
DR-3DR-2ROOF SNOW DRIFT SCHEDULE
40 PSFDR-1
DR-4
DR-5
MARK SURCHARGE, Pd
46 PSF
8 PSF
DRIFT WIDTH, W
9'-0"
20'-0"
5'-0"
DR-2
51 PSFDR-3 12'-0"
NOTES:
1. SEE SNOW DRIFT PLAN FOR PLAN FOR DRIFT LOCATIONS
AND EXTENTS.
2. SNOW DRIFT SURCHARGE, Pd, IS ADDITAVE TO THE FLAT
ROOF SNOW LOAD, Pf, INDICATED IN THE GENERAL
STRUCTURAL NOTES AS SHOWN IN THE DIAGRAM BELOW:
27 PSF 12'-6"
Pf Pf
3/8"Pd
1 7/ 8"
W
ROOF JOIST SCHEDULE, UNO
2x8 @ 24" OCRJ1
14" RED-I45 @ 24" OCRJ2
RJ3
RJ4 LVL1 3/4x14
LVL3 1/2x14
RJ5 14" RED-I65 @ 24" OC
RJ6 2-14" RED-I65 @ 24" OC
737 BISHOP STREET, SUITE 1860
HONOLULU, HI 96813
808-352-5299
OWNER:
523 EAST THIRD AVENUE
SPOKANE, WA 99202
P 509.323.9292
F 509.747.7115
HOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 99216ROOF FRAMING PLAN -
WEST WING
S128
FSC PROJECT NO. 21012
PERMIT SET
5/31/2024
GL8 Mirabeau
Point, LLC
10909 E. Pierce Lane
Spokane, WA 99206
(509) 919-0901
NORTHSCALE:1/8" = 1'-0"
ROOF FRAMING PLAN - WEST WING
SCALE:3/64" = 1'-0"
SNOW DRIFT PLAN
Revision Schedule
Number Description Date
E F G H J K
L
L
M N P
4
5
6 6
7 7
8 8
9 9
C.1 L.1 Q
10 1060'-3 1/2"23'-11 5/8"6'-1 1/4"24'-2 5/8"6'-0"6
S501
__________
9
S501
__________
6
S501
__________
6
S501
__________
7
S501
__________
6
S501
__________
6
S501
__________54'-3 1/2"TYP 5/8" APA RATED SHTGRJ2RJ2RJ2RJ2RJ2RJ2RJ2RJ2RJ2RJ2RJ2RJ5RJ5RJ2RJ2RJ2RJ2RJ2RJ2RJ2RJ2RJ1RJ1
19'-0 7/8"19'-0 3/4"19'-1"19'-0 7/8"19'-0 3/4"14'-11"19'-1 1/2"10'-9"14'-11 1/4"19'-1 1/2"19'-9 1/8"
4'-2 5/8"
193'-11 5/8"
__________
S502
2 TYP @ WALL
OFFSET
16
S501
__________
2 2 2 2RJ5
RJ5
RJ4
2 RJ5
RJ5
RJ3
RJ2
RJ3
RJ2
RJ3
RJ2
RJ3
RJ2
2
RJ4 RJ4
2
RJ4
2
1
S502
__________
TYP @
INTERIOR
BRG WALLS
__________
S502
3__________
S502
3 __________
S502
3
__________
S502
3
__________
S502
3
RJ5
RJ5
RJ5
RJ5
ERV-01
6,500#
CU-02
1,500#
CU-03
1,500#
RJ4RJ4
RJ2 RJ2RJ219
S501
__________
14
S501
__________
14
S501
__________17
S501
__________
17
S501
__________RJ6
RJ6
RJ6
RJ6
RJ6
RJ6
RJ6
RJ6 RJ5RJ5GL5 1/2x14 GL5 1/2x14
HSS8x4x1/4
HSS8x4x1/4
(62'-10")
(62'-10")
HSS8x4x1/4
(62'-10")
W8x18, 2 PLCS
(62'-10"), SEE NOTE 6
11
S502
__________
13
S502
__________
1. SEE S0-SERIES SHEETS FOR GENERAL STRUCTURAL NOTES,
ABBREVIATIONS, LEGEND & TYPICAL DETAILS.
2. COORDINATE AND VERIFY ALL DIMENSIONS WITH ARCHITECTURAL
DRAWINGS.
3. REFER TO ALL ARCHITECTURAL, ELECTRICAL, & MECHANICAL
DRAWINGS FOR PROPER COORDINATION WITH OTHER TRADES.
4. VERIFY MECHANICAL UNIT LOCATIONS. IF UNITS ARE NOT PLACED
WHERE INDICATED ON THIS PLAN CONTACT THE STURTURAL ENGINEER
PRIOR TO TRUSS FABRICATION.
5. COORDINATE ATTIC VENTING REQUIREMENTS WITH ARCHITECTURAL
DRAWINGS.
6. ELEVATOR HOIST BEAMS HAVE BEEN DESIGNED TO SUPPORT 7.5 KIP
LOADS AT ANY LOCATION ALONG BEAM. SEE DETAILS FOR HOIST
BEAM & RAIL COLUMN CONNECTIONS.
ROOF FRAMING PLAN NOTES
E F G H J K L M N P
5
6
7
8
9
Q
10
DR-5
DR-5
DR-5DR-1 DR-1
DR-1DR-1 DR-4DR-1
DR-3DR-1DR-1DR-1
DR-1
DR-1
ROOF SNOW DRIFT SCHEDULE
40 PSFDR-1
DR-4
DR-5
MARK SURCHARGE, Pd
46 PSF
8 PSF
DRIFT WIDTH, W
9'-0"
20'-0"
5'-0"
DR-2
51 PSFDR-3 12'-0"
NOTES:
1. SEE SNOW DRIFT PLAN FOR PLAN FOR DRIFT LOCATIONS
AND EXTENTS.
2. SNOW DRIFT SURCHARGE, Pd, IS ADDITAVE TO THE FLAT
ROOF SNOW LOAD, Pf, INDICATED IN THE GENERAL
STRUCTURAL NOTES AS SHOWN IN THE DIAGRAM BELOW:
27 PSF 12'-6"
Pf Pf
3/8"Pd
1 7/ 8"
W
ROOF JOIST SCHEDULE, UNO
2x8 @ 24" OCRJ1
14" RED-I45 @ 24" OCRJ2
RJ3
RJ4 LVL1 3/4x14
LVL3 1/2x14
RJ5 14" RED-I65 @ 24" OC
RJ6 2-14" RED-I65 @ 24" OC
STRAP SCHEDULE
STRAP NOTES:
1. CMST14 MIN LAP SPLICE LENGTH = 14"
(13-0.162x2 1/2" NAILS)
2. SHORTER NAIL SUBSTITUTIONS ARE
NOT ALLOWED @ STRAP SPLICES.
3. IF WOOD SPLITTING OCCURS, DOUBLE
THE LAP SPLICE LENGTH (OR STRAP
LENGTH FOR ) AND USE EVERY
OTHER ROUND NAIL HOLE.
4. NO STRAP MODIFICATION IS ALLOWED.
5. INSTALL STRAPS TIGHT, WOOD
SHRINKAGE AFTER STRAP
INSTALLATION ACROSS HORIZONTAL
WOOD MEMBERS MAY CAUSE STRAP TO
BUCKLE OUTWARD.
6. STRAPS INSTALLED OVER SHTG REQ 2
1/2" LONG NAILS MIN.
STRAPMARK
LSTA18
LSTI73
CMST14-2'-8"
1
2
3
4
5
6
7
CMST14-12'-0"
CMST14-20'-0"
CS14xCONT (AS SHOWN)
CMST14xPLAN DIM
3
737 BISHOP STREET, SUITE 1860
HONOLULU, HI 96813
808-352-5299
OWNER:
523 EAST THIRD AVENUE
SPOKANE, WA 99202
P 509.323.9292
F 509.747.7115
HOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 99216ROOF FRAMING PLAN -
EAST WING
S129
FSC PROJECT NO. 21012
PERMIT SET
5/31/2024
GL8 Mirabeau
Point, LLC
10909 E. Pierce Lane
Spokane, WA 99206
(509) 919-0901
NORTHSCALE:1/8" = 1'-0"
ROOF FRAMING PLAN - EAST WING
SCALE:3/64" = 1'-0"
SNOW DRIFT PLAN
Revision Schedule
Number Description Date
T.O.B.
T.O.B.
E F G H J
5 5
6 6C558C558C558C558C558C558C558
W16x26 W16x26 W18x35
3" 6'-1" 6'-3" 6'-3" 6'-3" 6'-3" 6'-3" 6'-1"
3"
1½"x20GA TYPE 'B' STL
ROOF DECK, GALV
W18x35
16
S401
__________
18
S401
__________W21x68W21x68W21x68W21x68
1
S402
__________
17
S401
__________17
S401
__________
W16x26
5
S402
__________
4 PLCS
W18x35 W18x35 W18x35
19
S401
__________
3
S402
__________C558T.O.S.
0"
T.O.F.
-2'-0"
E F G H J
HSS7x5x1/2HSS5x5x1/2HSS5x5x1/2HSS7x5x1/2HSS5x5x1/4HSS5x5x3/8 HSS5x5x3/8 HSS5x5x3/8 HSS5x5x3/8
W16x26 W16x26
W21x68
W16x26 W18x35
W21x68W21x68
HGRS @ 4'-0" OC
MAX (TYP)
W21x68
HSS5x5x1/217
S401
__________18
S401
__________17
S401
__________
(15'-6 1/4")
HSS5x5x3/8
HSS5x3x1/4
W21x68 19
S401
__________
__________
S007
19
TYP
T.O.F.
-2'-0"
EFGHJ
HSS5x5x1/4HSS5x5x1/4W21x68 W21x68HSS5x5x1/2HSS5x5x1/2HSS5x5x1/2HSS5x5x1/2HSS5x5x1/2HSS5x5x1/2HSS5x5x1/2HSS5x5x1/2W18x35 W18x35 W18x35
(13'-6")
__________
S007
3 HSS5x5x1/4
GIRT BEYOND
BTWN COLS
(TOP @ 13'-0")
__________
S007
3
CANOPY FRAMING
IN FOREGROUND
BALCONY FRAMING
IN FOREGROUND
17
S401
__________17
S401
__________
1
S402
__________
W21x68
__________
S402
5__________
S402
5 __________
S402
5
__________
S402
5
W21x68
BEYOND
__________
S402
3 __________
S402
3
OPP
737 BISHOP STREET, SUITE 1860
HONOLULU, HI 96813
808-352-5299
OWNER:
523 EAST THIRD AVENUE
SPOKANE, WA 99202
P 509.323.9292
F 509.747.7115
HOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 99216CANOPY FRAMING PLAN
& STEEL FRAME
ELEVATIONS
S130
FSC PROJECT NO. 21012
PERMIT SET
5/31/2024
GL8 Mirabeau
Point, LLC
10909 E. Pierce Lane
Spokane, WA 99206
(509) 919-0901
SCALE:1/8" = 1'-0"1 NORTH LOBBY CANOPY FRAMING PLAN
SCALE:1/8" = 1'-0"3 NORTH CANOPY INTERIOR FRAMING ELEVATION
SCALE:1/8" = 1'-0"5 NORTH CANOPY EXTERIOR FRAMING ELEVATION
Revision Schedule
Number Description Date
T.O.F.
T.O.S.
GRID
T.O.F.
T.O.S.
GRID
T.O.S.
T.O.F.
T.O.S.
T.O.F.
T.O.S.
T.O.F.
T.O.S.
T.O.F.
FINISH
GRADE
T.O.S.
T.O.C.
T.O.F.
TYP ELEVATOR COLUMN BASE CONN
8" CONC
2'-4"
2x6 STUDS
SEE PLAN
1"
(V)
2x6 STUDS
SEE PLAN
PLAN DIM
2'-4"
2x6 STUDS
SEE PLAN
4" (V)
PLAN DIM 1'-0" CONC W/
2x6 STUDS
SEE PLAN HSS COL
SEE PLAN
T.O.F.
Px-x
T.O.S.
Px-x
T.O. HSS
(V)
T.O. HSS
(V)
T.O. HSS
(V)
eTYP
-5'-0"
SEE
F.O. CONC
SEE
PLAN
(V)
SEE
PLAN
F.O. CONC
(V)V #4 @ 12" OC
H #4 @ 10" OC
EACH FACE
EMBED lyx12x1'-0" W/
4-s"∅x5" HAS
HSS BEAMS @ RAIL SUPPORTS
COORD & (V) LOCATIONS W/
ELEVATOR MFR.
NOTE:
SEE TYP HSS TO COL DETAIL FOR
CONNECTION OF HSS RAIL
BEAMS, TYP
THICKENED SLAB
SEE 8/S301
lix5ix0'-11" W/ 2-p"_x8"
TITEN HD @ 8" OCFROST DEPTH (MIN)STEM WALL
CTR ON3" CLR8" CONC STEM WALL
#4 V @ 16" OC (CNTRD)
#4 H @ 10" OC (3 MIN)
FOOTING SEE PLAN
FOR SIZE & REINF
SUBGRADE PREP PER
GEOTECH REPORT
ALT HOOK
IN FTG
F.O. CONC
AS OCCURS
2x6 STUDS
SEE PLAN
2x PT PLATE W/ 5/8"Ø AB PER
SHEARWALL SCHED OR 48" OC
MAX (7" EMBED)
EXTR WALL FINISH
SEE ARCHL
SLAB POUROVER
@ STOREFRONT &
DOORS PER TYP
DETAIL
SEE
PLAN Px-x
SEE PLAN
FROST DEPTH (MIN)STEM WALL
CTR ON3" CLR10" CONC STEM WALL
#4 V @ 12" OC (CNTRD)
#4 H @ 10" OC (3 MIN)
FOOTING SEE PLAN
FOR SIZE & REINF
SUBGRADE PREP PER
GEOTECH REPORT
ALT HOOK
IN FTG
SLAB POUROVER
@ STOREFRONT &
DOORS PER TYP
DETAIL
2x8 STUDS
SEE PLAN
2x PT PLATE W/ 5/8"Ø AB PER
SHEARWALL SCHED OR 48" OC
MAX (7" EMBED)
EXTR WALL FINISH
SEE ARCHL
SEE
PLAN Px-x
F.O. CONC
AS OCCURS SEE PLAN NOTES:
1. USE BASE PL3/4 ON 1 1/2" NON-SHRINK
GROUT W/ 15/16"⌀HOLES FOR TAS
2. USE EMBED L6x4x1/2 LLH W/
A. 2-5/8"⌀x6" HAS
B. 2-1/2"⌀x1'-0" DBA
C. 4-3/4"⌀TAS @ BASE PL
3"
MIN
1/4"1 1/2"1 1/2"MIN
5 1/2"
TAS 3"
MIN
1/4"
MIN
5 1/2"
TAS
1 1/2"1 1/2"BLDG
INTERIOR
1 1/2"1 1/2"
TAS
3"
MIN
5 1/2"
MIN
1/4"
BLDG
INTERIOR
1"2"2"4"4"1'-0"HAS
DBA
CL COL &
EMBED
1'-0"1'-0"BLDG
INTERIOR
BLDG
INTERIOR 11"BASE PL BASE PL BASE PL
EMBED
PLAN -STRAIGHT WALL
EMBED
PLAN -INSIDE CORNER
EMBED
PLAN -OUTSIDE CORNER
STEM WALL & FOOTING
(SEE PLANS & DETAILS)4"
2TYP
1/4
HSS COL
SEE NOTE 1
CL COL
CL STUD
F.O. CONC
11"
NOTE:
CONTRACTOR MAY REPLACE CAST-IN ANCHOR
BOLTS WITH TITEN HD SCREWS OR ADHESIVE
ANCHORS OF SAME DIAMETER, SPACING, & EMBED.
CTR ON WALL
SEE PLAN PLANSEECONT REINF
PER SCHED
(SEE PLAN @
RIGHT)CLR3"#4 @ 24" OC
CLR1 1/2"2x PT PLATE W/ 5/8"Ø AB
PER SHEARWALL SCHED
OR 48" OC MAX
(7" EMBED) -SEE NOTE
Px-x SEE
PLAN
WOOD STUDS
SEE PLAN
SUBGRADE PREP & BEARING CONDITIONS
UNDER THICKENED SLAB SECTION SHALL
BE SAME AS FOR BLDG FOUNDATION
(SEE GEOTECH REPORT)
1'-6" MIN
2'-0" MIN LAPSLAB
THICKENED5"PLAN @ INTERSECTING STEM WALLS
CONT REINF
FDN STEM WALL
(SEE PLAN & DTLS)
#4x3'-0" AD @
EA SLAB BAR
STEM WALL
CTR ON3" CLR8" CONC STEM WALL
#4 V @ 16" OC (CNTRD)
#4 H @ 10" OC (3 MIN)
FOOTING SEE PLAN
FOR SIZE & REINF
SUBGRADE PREP PER
GEOTECH REPORT
ALT HOOK
IN FTG
WOOD STUDS
SEE PLAN
2x PT PLATE W/ 5/8"Ø AB PER
SHEARWALL SCHED OR 48" OC
MAX (7" EMBED)
SEE
PLAN Px-x
TYP
1"
REINF SLAB EDGE
PER TYP DETAIL
1"8"__________
S004
19
SLAB POUROVER @ INTERIOR DOOR
FRAMED WALL
BEYOND
℄COL
& FTG
FTG, SEE PLAN
SEE PLAN
HSS COL
CLR3"CONC PIER
2'-0" SQUARE
#4 TIES
12-#5 VERT
CONC PAVING
AS OCCURS
2" CLR
2'-0" MINTYP8" 3"2"2'-4"2" CLR3" CLR1'-6"2'-4"
(V)
PLAN DIM8" CONC (3) SIDES W/
V #4 @ 12"OC
H #4 @ 10"OC
CENTER REINF
2-#5 CONT
2x PT PLATE W/ 5/8"Ø AB
PER SHEARWALL SCHED OR
48" OC MAX (7" EMBED)
SEE NOTE 1
SEE TYPICAL DETAIL
FOR SLAB EDGE AT
DOORS
STUD WALL BEYOND
SEE
PLAN Px-x
2x6 STUDS
SEE PLAN
(V)
2 3/4"
F.O.C.
#6 @ 12" OC EA WAY
TOP & BOT
6"1'-6" SQ
VERIFY
1
1
1'-6"
3-#4 EW
8"(V)1'-6"CONDITION @ SUMP
NOTES:
1. COORDINATE SILL DETAIL W/ ELEVATOR
MFR
2. CONTRACTOR SHALL PROVIDE & LOCATE
SUMP PIT, GRATE, EMBEDS, & LADDER AS
REQ'D BY ELEVATOR MFR.
737 BISHOP STREET, SUITE 1860
HONOLULU, HI 96813
808-352-5299
OWNER:
523 EAST THIRD AVENUE
SPOKANE, WA 99202
P 509.323.9292
F 509.747.7115
HOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 99216FOUNDATION DETAILS
S301
FSC PROJECT NO. 21012
PERMIT SET
5/31/2024
GL8 Mirabeau
Point, LLC
10909 E. Pierce Lane
Spokane, WA 99206
(509) 919-0901
SCALE:3/4" = 1'-0"1 SCALE:3/4" = 1'-0"2 SCALE:3/4" = 1'-0"3
SCALE:3/4" = 1'-0"8SCALE:3/4" = 1'-0"6 SCALE:3/4" = 1'-0"10
SCALE:3/4" = 1'-0"16 S301/16 - WFT-6
SCALE:3/4" = 1'-0"18 S301/18 - WFT-8
Revision Schedule
Number Description Date
SEE ARCH
SEE ARCH
T.O. SHTG
WOOD STUDS
SEE PLAN
5 1/ 2"
WOOD STUDS
SEE PLAN
I-JST PER PLAN W/
SIMPSON DGT FIRE
WALL HGR
WEB
STIFF
TOPPING PER ARCHL
SEE SHEAR WALL SCHED
FOR BOT PLATE NAILING
SEE
PLAN Px-x
SEE
PLAN Px-x
DBL TOP PLATE
BELOW FLR SHTG
EN
EN
SEMI-BALLOON FRAMING
T.O. SHTG
PARTIAL WALL PROFILE
ALIGN STUDS ABOVE
FLOOR LEVEL W/
STUDS BELOW
OFFSET
1 1/2" MAX
DBL TOP PLATE
BOTTOM PLATE
T.O. SHTG
WOOD STUDS
SEE PLAN
5 1/ 2"
WOOD STUDS
SEE PLAN
5 1/ 2"
TOPPING PER ARCHL
SEE SHEAR WALL SCHED
FOR BOT PLATE NAILINGSEE
PLAN Px-x
SEE
PLAN Px-x
DBL TOP PLATE
BELOW FLR SHTG
EN
EN
4-8d INTO BLKG
2x4 MIN FLAT BLKG
@ 24" OC
CONT 2x6 MIN LEDGER OVER
GYPBOARD W/ SIMPSON
SDWS 0.22x5" TIMBER
SCREWS @ 12" OC
SEMI-BALLOON FRAMING
I-JST
T.O. SHTG
WOOD STUDS
SEE PLAN
5 1/ 2"
WOOD STUDS
SEE PLAN
5 1/ 2"
TOPPING PER ARCHL
SEE SHEAR WALL SCHED
FOR BOT PLATE NAILING
SEE
PLAN Px-x
SEE
PLAN Px-x
I-JST PER PLAN W/
WEB STIFF PER MFR
(SEE PLAN @ RIGHT)
1 1/2" LVL/LSL BLKG BTWN
JOISTS (FACE NAIL TO RIM
W/ 2-ROWS 10d @ 6" OC)
CONT 1 1/2" LVL/LSL
RIM @ WALL CL
(SEE SHEAR WALL
SCHED FOR BOT
CLIP @ WALL PL)
WALL CL
PLAN VIEW
BELOW
WALL
FLR JST FLR JST
FLR JST FLR JST
FLR JST FLR JST
CONT RIM @ WALL CL
NAILED TO JOIST
FLANGES ON ONE SIDE
PER MFR
BLKG BTWN JOISTS THAT ARE
NOT NAILED TO RIM (OR AS
REQ'D FOR BOT PL NAILING)
W8 JST
W BM
STRAP PL1/4x3x2'-0"
3/16
L3x2 1/2x1/4x0'-5"
(LLH) EA SIDE3/16
3'-11"
L3x3x1/4 CONT
3/16
END PL1/4
W8 JST
1'-0"
W8 JST
HSS5x3x1/4 HGRS
@ 4'-0" OC MAX
(SEE FRAME ELEV)
PL1/4x3" SQ EA SIDE
2"I-JST PER PLAN
STOREFRONT
(SEE ARCHL)
SEE PLAN
WOOD STUDS
STIFF PL EA SIDE
@ HSS HGRS
3/16 ALL SIDES
3/16
HSS WALL-GIRT HANGERS
T.O. SHTG
2x6 BLKG @ 24" OC
W/ JB26 HGR EA END
STUDS & SHTG TO
MATCH WALL ABOVE
BALCONY
AS OCCURS
__________
S401
3 2 ROWS 10d @ 8" OC
STAGGERED
DBL 2x6 NAILER W/
5/8"ø HAS @ 24" OC
W BEAM
INFILL W/ 2x6 STUDS @
16" OC (FASTEN TOP &
BOT PLATES W/ SIMPSON
TF SCREWS @ 16" OC
SEE DTL ABOVE FOR
HANGERS & BRACES
CANOPY FRAMING
AS OCCURS
HSS5x5 WALL GIRT
(SEE FRAME ELEV)
W BEAM
HSS WALL GIRTMAX1/2"L3x3x1/4 CONT
SEE ABOVE
3/16
SIMPSON
TF SCREW
@ 16" OC
(ALT SIDES)
W BEAM
JST-TO-BM CONN
__________
S007
13
L3x3x1/4 BRACE
@ EA HSS HGR W/
2" LAP EA END
3/16 3-12
CONT L3x3
W BEAM
3/16EA END
__________
S401
6
T.O. SHTG
I-JST PER PLAN W/
WEB STIFF PER MFR
AS NEEDED
W BEAM
ITS HGR
WOOD STUDS
SEE PLAN
(AS OCCURS)
5 1/ 2"
SEE SHEAR WALL SCHED
FOR BOT PLATE NAILING
SEE
PLAN Px-x
TOPPING PER ARCHL
DBL 2x NAILER W/ 5/8"ø
TAS @ 24" OC
(SEE DTL @ RIGHT)
Bf UP TO 7 1/2"
Bf
Bf UP TO 11 1/2"
Bf
1 1/2"1 1/2"
CL W BEAM
TAS @ CL BM
NOTES:
1. NAILERS SHALL BE RIPPED FROM SOLID
LUMBER TO FIT WIDTH OF BEAM FLANGE TO
WITHIN 1/8" MAX UNDER OR OVER EACH SIDE.
2. CONNECT PLATES W/ 10d @ 6" OC,
ALTERNATING SIDES OF BEAM CL.
TAS ALT SIDES
OF BEAM CL
SEE NOTE 2
SEE NOTE 1
W BEAM
W8 JST
SEE PLAN
WOOD STUDS
T.O. SHTG
I-JST PER PLAN
2 ROWS 10d @ 8" OC
STAGGERED
PONY WALL W/ 2x6
STUDS @ 16" OC
W BEAM
BEYOND
W BEAM W/ STIFF PL
EA SIDE @ HSS HGRS
HSS5x5
WALL GIRT
HSS5x3 HGRS
SEE FRAME ELEV
& DTL 17/S4.01
5/8"ø HAS
@ 16" OC
__________
S402
1
__________
S401
17
L3x3x1/4 BRACE
@ EA HSS HGR
(SEE DTL 17/S4.01)
__________
S401
17
T.O. SHTG
SEE PLAN
WOOD STUDS __________
S401
17
I-JST PER PLAN
STUDS & SHTG TO
MATCH WALL ABOVE
SIMPSON TF SCREW
@ 16" OC (ALT SIDES)
W BEAM
3-12HSS5x5x3/8
CONT (SEE
ABOVE)
W BEAM
SEE PLAN
WOOD STUDS
STAGGER SHEAR WALL
EDGE NAILING
CONT DBL TOP PLATES
INDIVIDUALLY
FASTENED
TOP PLATE W/
2 ROWS TF SCREWS
@ 8" OC (STGRD)
BOT PLATE W/
2 ROWS 10d @ 8" OC
(STGRD)
HSS COL
DETAIL @ EACH END OF HSS5x5
CONT HSS5x5
W BEAM W BEAM
L4x4x3/8 x0'-5"
MAX
1/2"
1/4
__________
S007
13
737 BISHOP STREET, SUITE 1860
HONOLULU, HI 96813
808-352-5299
OWNER:
523 EAST THIRD AVENUE
SPOKANE, WA 99202
P 509.323.9292
F 509.747.7115
HOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 99216FLOOR FRAMING
DETAILS
S401
FSC PROJECT NO. 21012
PERMIT SET
5/31/2024
GL8 Mirabeau
Point, LLC
10909 E. Pierce Lane
Spokane, WA 99206
(509) 919-0901
SCALE:3/4" = 1'-0"1 SCALE:3/4" = 1'-0"3 SCALE:3/4" = 1'-0"4
SCALE:3/4" = 1'-0"16 SCALE:3/4" = 1'-0"17
SCALE:3/4" = 1'-0"6
SCALE:3/4" = 1'-0"18 SCALE:3/4" = 1'-0"19
Revision Schedule
Number Description Date
6 6
W BM
BEYOND
CONT BENT PL3/8
5"3 "
362S162-43 SOFFIT
JST @ 16" OC362S162-43 SOFFIT
JST @ 16" OC
W BM
W BM
5'-1"
W BM
W BM
W BEAM
SECTION VIEWEND VIEW
4-3/4"ø HSB
@ BM GAGE
STIFF PL EA SIDE
@ BM CL
W BEAM
STIFF PL EA SIDE
@ BM CL
CONTINUOUS
W BEAM
STIFF PL 3/8
EA SIDE
2" CLR 2" CLR
1/4
HSS5x5x1/2 STUB COL BASE PL 5/8
W/ 4-3/4"ø HSB
STIFF PL 3/8
EA SIDE
NOTE:
IT IS ACCEPTABLE TO
PROVIDE SSL HOLES IN BEAM
FLANGE, PARALLEL WITH BEAM.
SEE NOTE
W BEAM
BASE PLATE
1 1/2" 1 1/2"6"1 1/4"1/4
BM CL
MIN6"STUB COL
2 3/4"
SEE PLAN
W BEAM
SECTION VIEWEND VIEW
BASE PLATE
.1 1/2"6"1 1/4"1/4
TYP COL &
STIFF PL
PLAN
W BEAM HSS COL
__________
S007
1
W BEAM EA SIDE
1 1/2"SPLIT HSS5x5x1/2
EA SIDE
__________
S007
61/4
L4x4x3/8 EA SIDE
W/ 6-3/4"ø HSB
W BEAM
3"1 1/2".1 1/2"
4"
1/4 EA ANGLE
STIFF PL
@ CL COLS W BEAM
BASE PL 5/8
W/ 6-3/4"ø HSB
STIFF PL 3/8
DBL HSS COLS
4"BALCONY FRAMING
SEE DTLS
SEE NOTE
__________
S007
8
NOTE:
IT IS ACCEPTABLE
TO PROVIDE SSL
HOLES IN BEAM
FLANGE, PARALLEL
WITH BEAM.
SECTION VIEWEND VIEW
CONTINUOUS
W BEAM
BALCONY FRAMING
SEE DTLS
HSS COL
__________
S007
11
W16x26
W BEAM
SEE TYP
DETAILS
HSS COL
737 BISHOP STREET, SUITE 1860
HONOLULU, HI 96813
808-352-5299
OWNER:
523 EAST THIRD AVENUE
SPOKANE, WA 99202
P 509.323.9292
F 509.747.7115
HOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 99216FLOOR FRAMING
DETAILS
S402
FSC PROJECT NO. 21012
PERMIT SET
5/31/2024
GL8 Mirabeau
Point, LLC
10909 E. Pierce Lane
Spokane, WA 99206
(509) 919-0901
SCALE:3/4" = 1'-0"11 SCALE:3/4" = 1'-0"13 SCALE:3/4" = 1'-0"15
SCALE:3/4" = 1'-0"1 SCALE:3/4" = 1'-0"3 SCALE:3/4" = 1'-0"5
Revision Schedule
Number Description Date
GRID
T.O.P.
GRID
J.B.
GRID
GRID
T.O.P.
GRID
T.O.P.
F.O. STUD
AS OCCURS
PARAPET CAP
SEE ARCHL
DBL 2x6 TOP PL
2x6 BLKG
EN
2x6 BLKG @ 16" OC,
ALIGN W/ STUDS
(PROVIDE BLKG 3 BAYS
IF FIRST BAY IS LESS
THAN 16")
LSL1 1/2x14 LEDGER W/
3-SDWS22500 EA STUD &
16d @ 6" OC TO 2x6 BLKG
H2A
8d @ 4" OC
2"4" 4"
EN
LTS12 EA STUD
F.O. STUD
AS OCCURS
PARAPET CAP
SEE ARCHL
DBL 2x6 TOP PL
H2A EA STUD
8d @ 4" OC
2x6 KICKER EA
SIDE OF STUD
CONT ROOF PL1/4x8 W/ 2-ROWS
SDS25400 @ 16" MAX OC
(STGRD, 8" OC NET)
SEE PLAN
SIDE PL3/16 W/ 2-SDS25200
2-SDWS22400 EA
SIDE (4 TOTAL,
STGR SCREWS FS)
1 1/2"1 1/2"1 1/2"1 1/2"1 1/2"3"1 1/2"1
1
1/8
1/8
SIDE PL WELDS
MSTA49 (FILL EVERY
OTHER NAIL HOLE)
5 1/ 2"
WOOD STUDS
SEE PLAN
AS OCCURS
SEE PLAN Px-x
5 1/ 2"
WOOD STUDS
SEE PLAN
I-JST PER PLAN
1 3/4" LVL/LSL RIM
(SEE SHEAR WALL SCHED
FOR CONNECTION INFO
& ADDL BLKG)
2x JST PER PLAN
LUS28 EA END
ENEN
DBL 2x6 TOP PL
EN
2x6 BLKG @ 24" OC
LSL1 1/2x14 LEDGER W/
3-SIMPSON SDWS22500
EA STUD & 16d @ 6" OC
TO 2x6 BLKG 12" OC
F.O. STUD
SEE PLAN SEE PLAN
2x12 OUTLOOKER
EN
SEE FOR ADDL INFORMATION__________
S501
9
LVL5 1/4x14 BLKG
SP6 EA STUD
2-ROWS SDWS TIMBER SCREWS @
16" OC (STGRD, 8" OC NET)
SDWS22600 TOP SIDE &
SDWS22800 BOT SIDE
LTP5 @ 16" OC
F.O. STUD
AS OCCURS
PARAPET CAP
SEE ARCHL
DBL 2x6 TOP PL
WOOD PARAPET STUDS
SEE PLAN
SEE
PLAN Px-x
5 1/ 2"
I-JST
LSL1 1/2x14 RIM BOARD WEB
STIFF2'-0"CS20 STRAP EA STUD
(NOT REQUIRED @ SIM)9"9"WOOD STUDS
SEE PLAN
5 1/ 2"
5 1/ 2"
2x6 BRACE EA STUD
(NOT REQUIRED @ SIM)
SEE NOTE
CS20 STRAP W/ 10"
MIN END LENGTH EA
FACE OF STUD 10"NOTES:
1. ALIGN PARAPET STUDS WITH
WALL STUDS BELOW TO
ACCOMODATE COIL STRAP
2. SHEATH BACK SIDE OF
PARAPET AND 2x6 BRACE W/
5/8" APA RATED ROOF SHTG
4x6 BLKG W/
2-A34 EA END
A34
SDWS22600
@ 8" OC
F.O. STUD
AS OCCURS
PARAPET CAP
SEE ARCHL
DBL 2x6 TOP PL
WOOD PARAPET STUDS
SEE PLAN
SEE
PLAN Px-x
I-JSTLVL5 1/4x14 BLKG
WEB
STIFF2'-0"WOOD STUDS
SEE PLAN
5 1/ 2"
2x6 BRACE EA STUD
SEE NOTE
CS20 STRAP W/ 10"
MIN END LENGTH EA
FACE OF STUD 10"SP6 EA STUD
2-ROWS SDWS TIMBER SCREWS @
16" OC (STGRD, 8" OC NET)
SDWS22600 TOP SIDE &
SDWS22800 BOT SIDE
5 1/ 2"
LTP5 @ 16" OC
4x6 BLKG W/
2-A34 EA END
A34
SDWS22600
@ 8" OC
737 BISHOP STREET, SUITE 1860
HONOLULU, HI 96813
808-352-5299
OWNER:
523 EAST THIRD AVENUE
SPOKANE, WA 99202
P 509.323.9292
F 509.747.7115
HOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 99216ROOF FRAMING
DETAILS
S501
FSC PROJECT NO. 21012
PERMIT SET
5/31/2024
GL8 Mirabeau
Point, LLC
10909 E. Pierce Lane
Spokane, WA 99206
(509) 919-0901
SCALE:3/4" = 1'-0"6 SCALE:3/4" = 1'-0"7
SCALE:3/4" = 1'-0"19
SCALE:3/4" = 1'-0"9
SCALE:3/4" = 1'-0"14
SCALE:3/4" = 1'-0"16 SCALE:3/4" = 1'-0"17
Revision Schedule
Number Description Date
J.B.
TYP T.O. HSS COLUMN
2x6 STUDS
SEE PLAN
2x6 STUDS
SEE PLAN
2x6 STUDS
SEE PLAN
T.O.W.
VARIES
T.O.B.
61'-2"
62'-10"
HSS COLS BEYOND
T.O. JOIST
2x8
HSS BOLTED CONN TO
WALL TOP l'S
SEE DETAIL 21
W8 HOIST BEAM
(V) ELEVATION &
LOCATION W/ ELEVATOR
MFR
HSS BEAM IN WALL
BEYOND
TYP HSS BEAM TO COL
1/2" CLR
2x6 STUDS
SEE PLAN
2x6 STUDS
SEE PLAN
2x6 STUDS
SEE PLAN
T.O. HSS
(V)
W8 W8
T.O.B.
TYP
T.O. HSS
(V)
65'-6"
62'-10"
T.O.P.
HSS BEAMS @ RAIL SUPPORTS
COORD & (V) LOCATIONS W/
ELEVATOR MFR.
NOTE:
SEE TYP HSS TO COL DETAIL FOR
CONNECTION OF HSS RAIL
BEAMS, TYP
SEE TYPICAL BOLTED STEEL
CONNECTION DETAIL, TYP
HSS BEAMS @ W8 HOIST BEAM COORD
& (V) LOCATIONS W/ ELEVATOR MFR.
SEE TYPICAL WOOD STUD
ATTACHMENT TO COLUMN
FOR SIM CONNECTION, TYP
HSS BEAM
m4x3 PER HSS BEAM TO
COL DETAIL
WOOD STUDS
SEE PLAN5 1/ 2"
SEE
PLAN Px-x
I-JST PER PLAN W/
WEB STIFF PER MFR
AS NEEDED
1 1/2" LVL/LSL BLKG
(SEE SHEAR WALL SCHED
FOR CONNECTION INFO
& ADDL BLKG)
EN
ROOF JST
PER PLAN
1 3/4" RIM
BOARD
2-ROWS SDWS22500
@ 6" OC
(ALT SIDES & STGR
ROWS, 10 SCREWS
TOTAL)
3" 4 SPCS @ 6" 3"
1 3/4x14x2'-6" LVL/LSL
SPACER BLKGPRIVATE ROOMCOORIDOOR1 3/4" RIM BOARD19
S501
__________
INTERIOR OFFSET WALL PLAN
LVL JST
PER PLAN
6
S501
__________
EXTERIOR OFFSET WALL PLAN
STRAP PER
PLAN
BLKG PER
PLANS & DTLS
1
S502
__________
I-JST
PER PLAN
LEDGER
NOTES:
1. BUTT LEDGER TIGHT TO LVL JOIST & CENTER STRAP ON JOINT.
2. 2x LEDGERS THAT ARE STRAPPED @ WALL OFFSETS SHALL BE CONTINUOUS
BETWEEN INTERIOR BEARING WALL LINES.
EXTERIOR BALLOON
FRAMED WALLS
INT BRG WALL BELOW
737 BISHOP STREET, SUITE 1860
HONOLULU, HI 96813
808-352-5299
OWNER:
523 EAST THIRD AVENUE
SPOKANE, WA 99202
P 509.323.9292
F 509.747.7115
HOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 99216ROOF FRAMING
DETAILS
S502
FSC PROJECT NO. 21012
PERMIT SET
5/31/2024
GL8 Mirabeau
Point, LLC
10909 E. Pierce Lane
Spokane, WA 99206
(509) 919-0901
SCALE:3/4" = 1'-0"1 SCALE:3/4" = 1'-0"2 SCALE:3/4" = 1'-0"3
Revision Schedule
Number Description DateSCALE:3/4" = 1'-0"11 SCALE:3/4" = 1'-0"13
GRID
HSS8x3x3/16 HSS8x3x3/16
HSS8x4x3/8HSS8x4x3/8HSS8x4x3/8HSS8x4x3/8HSS8x3x3/16HSS8x3x3/16
11
S601
__________
8
S601
__________8
S601
__________
14
S601
__________14
S601
__________
SIM
HSS8x3x3/16
HSS8x4x3/8HSS8x3x3/16 HSS8x4x3/811
S601
__________
8
S601
__________
14
S601
__________
HSS8x3x3/16
HSS8x4x3/8HSS8x4x3/8HSS8x3x3/16
11
S601
__________
8
S601
__________
19
S601
__________
T.O. SHTG
400S162-54 STL JOISTS
@ 16" OC (UNPUNCHED) W/
CONT TRACKS EA END
(FASTEN TRACKS TO HSS
W/ PAF @ 16" OC)
FLR LEVEL
SEE ARCHL
NOTE 34 3/4"3 1/2"HSS8x3
3/4" APA-RATED SHTG OVER
STL JOISTS (FLUSH W/ T.O. HSS)
FASTEN W/ #8 SCREWS @ 6" OC
EDGES & FIELD
SLOPED CONC TOPPING
W/ 6x6-W2.9xW2.9 WWF
(SEE NOTE 2)
SEE
NOTE 1
NOT @ ADA UNITS1/2" STEPCONT L 2 1/2x2 1/2x1/4
EA END OF STL JSTS CONT L 2 1/2x2 1/2x1/4
FLOOR FRAMING
SEE PLAN & DTLS
5'-3 1/2"
F.O. STUD
HSS8x3
3/16 3-12
3-12
3/16 3-12
NOTES:
1. PROVIDE WATERPROOFING MEMBRANE BTWN
CONCRETE & WOOD.
2. SEE ARCHL FOR WATERPROOFING SYSTEM ON
CONCRETE SURFACE.
3. TOP OF STEEL HSS FRAME IS 4 1/4" BELOW FLOOR
LEVEL @ ADA UNITS.2 1/2"2 1/2"PLAN - CONNECTIONS AT HSS FRAME
HSS8x4 HSS8x4
HSS8x4 HSS8x4
HSS8x4 HSS8x4
HSS8x3HSS8x3HSS8x3HSS8x3GAP TYP1/2" MAXL 2 1/2x2 1/2x1/4 x0'-4"
EA CORNER
CAP PL 1/4 @ ALL OPEN
ENDS OF HSS MEMBERS
(SEAL WELD)
3/16HSS8x4
3/16
3 SIDES
HSS8x3
AT DOUBLE
BALCONIES
3 1/4"
5"VARIESVARIESBALCONY EDGE CONDITION
CNTR CONDITION @ DBL BALCONY
HSS8x4
3/16
3-12
3-12
CONT BENT PL 1/4
W/ 1/2"øx4" HAS @
12" OC
3"2"STEEL EDGE JOIST
W/ PAF @ 12" OC
CONC TOPPING
OVER FRAMING
__________
S601
11
HSS8x4
STEEL EDGE JOIST
W/ PAF @ 12" OCCONC TOPPING
OVER FRAMING
__________
S601
11
7"2"CONT PL 1/4 W/ 1/2"øx4"
HAS EA SIDE @ 12" OC
3/16 3-12
3/16 3-12
T.O. SHTG
I-JST
HSS-TO-HSS CONNECTION 1 1/2"3 1/2"2 1/2"
1/4
TOP PL 3/8
TOP PL 3/8
1/4 T&B EA SIDE
HSS COL
HSS8x4
END PL 1/2
1/4
1"1/2"HSS8x4
1/4
HSS8x4
SEE HSS-TO-HSS
CONN ABOVE
HSS COL
MAX
1/4"
SIDE PLATES
HSS COL
8d @ 3" OC
ALONG BLKG
SIDE PLATES SEE BELOW
(ALIGN W/ HSS8x4)
1 1/2"
PL3/8x8x8 EA SIDE W/
2-5/8"ø THRU BOLTS @ 5" GA
3/16EA SIDE PL
SIMPSON DTT2Z W/ 1/2"ø THRD
ROD & 1/4x2 1/2" SDS SCREWS
LVL BLKG
3 1/2" LVL FULL-DEPTH
BLKG (3 BAYS)
A35 CLIPS EA SIDE
& EA END OF BLKG
(PROVIDE FILLER
BLOCK @ JST WEB)
HSS COL
4"WALL FINISH
HSS8x4
HSS8x4
PLAN AT DBL COLUMN (SIM CONDITION)
DBL COLUMN (SIM CONDITION)PLANSEECOMBINED
TOP PL 3/8
1 1/2"3 1/2"2 1/2"
HSS COLS
T.O. SHTG
HSS8x4
HSS COL
WALL FINISH
4'-6"
CL COL
__________
S601
14
MAX
1/4"
3 1/2" LVL STRUT TO
MATCH JOIST DEPTH
8d @ 3" OC ALONG
STRUT (STAGGER)
3 1/2" LVL HEADER
BTWN JOISTS
SIMPSON HUCQ412
HANGER
FLR JST
FLR JST
LVL HEADER W/
HUCQ412 HGRS
LVL STRUT
PLAN VIEW
FLR JST BEYOND
737 BISHOP STREET, SUITE 1860
HONOLULU, HI 96813
808-352-5299
OWNER:
523 EAST THIRD AVENUE
SPOKANE, WA 99202
P 509.323.9292
F 509.747.7115
HOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 99216ENLARGED BALCONY
PLANS & DETAILS
S601
FSC PROJECT NO. 21012
PERMIT SET
5/31/2024
GL8 Mirabeau
Point, LLC
10909 E. Pierce Lane
Spokane, WA 99206
(509) 919-0901
SCALE:1/4" = 1'-0"C ENLARGED DOUBLE BALCONY PLAN
SCALE:1/4" = 1'-0"A ENLARGED SINGLE BALCONY PLAN - PARALLEL FRAMING
SCALE:1/4" = 1'-0"B ENLARGED SINGLE BALCONY PLAN - PERPENDICULAR FRAMING
SCALE:3/4" = 1'-0"11
SCALE:3/4" = 1'-0"8
SCALE:3/4" = 1'-0"14
SCALE:3/4" = 1'-0"19
Revision Schedule
Number Description Date
DDDD
WWWW
UP
UP
DN
UP
DN UP
5
3
3.1
6.1
2.1
D
C.1
FG
ML.1EC
C
B
B
1
11
EMPLOYEEROOM
110
POOL &SPLASHPAD
101
ELECTRICAL
104
POOL MEP
103
POOLRESTROOM
102
BOHLAUNDRY
105
BOHDRYERS
105A
LINENDISCHARGE& SORTING
107
LINENCHUTE
140
ELEVATORLOBBY
117
ELEV 1
111
ELEV 2
113
WATERHEATER &FIRE
108
STAIR 1
106
LAUNDRYLOUNGE
112
FITNESS
114
MEN'SRESTROOM
116
LINENSTORAGE
109
GUESTSTORAGE
118
WOMEN'SRESTROOM
115
8.1
9
4
1.1
A
K N P Q
2
LOBBY
121
FOOD PREP
123
PUBLICCORRIDOR
121A
GUESTCORRIDOR
139
EFFICIENCY
129
EFFICIENCY
131
EFFICIENCY
133
DOUBLEQUEEN
135
KINGSTUDIOADA-M-T
138
DOUBLEQUEEN
136
EFFICIENCY
134
STAIR 2
132
KINGSTUDIO
130
OPENOFFICE
124
GM OFFICE
125VESTIBULE
122
MEETINGROOM
120
MEETINGSTORAGE
119
SALESOFFICE
126
OWNER'SOFFICE
127
ELECTRICAL
128
COURTYARDSTORAGE
141
VESTIBULE
139A
PUBLICCORRIDOR
100
VESTIBULE
100A
EMP RRADA
110AEMP RR
110B
7
8
6
10
H
J
KINGSTUDIO
137
LANAI
137A
LANAI
135A
57' - 7"
13 sec
67' - 3"
15 sec
84' - 7"
19 sec
91' - 9"
21 sec
97' - 7"
22 sec
L
5
3
3.1
6.1
2.1
D
C.1FG ML.1EC
C
B
B
1
8.1
9
4
1.1
A
K N P Q
2
KING1-BEDROOMADA-M-T
x01
CONNECTINGCORRIDOR
x00
KING1-BEDROOM
x02
KINGSTUDIO
x04
EFFICIENCYENLARGED
x03
EFFICIENCY
x05
EFFICIENCY
x07
LINENS &HOUSEKEEPING
x09
EFFICIENCY
x08
DOUBLEQUEEN
x10
STAIR 1
x06
DOUBLEQUEENENLARGED
x12
KINGSTUDIO
x14KINGSTUDIO
x16
KINGSTUDIO
x18
KINGSTUDIO
x20
ELEV 1
111
ELEV 2
113
ELEVATORLOBBY
x17KINGSTUDIO
x19
KINGSTUDIO
x21
KINGSTUDIO
x23
KINGSTUDIO
x25
EFFICIENCY
x27
EFFICIENCY
x29
EFFICIENCY
x31
EFFICIENCY
x33 DOUBLEQUEEN
x35
KINGSTUDIO
x37
KINGSTUDIOADA-M-RI
x38
DOUBLEQUEEN
x36
EFFICIENCY
x34
STAIR 2
x32
KINGSTUDIO
x30
EFFICIENCY
x28
KINGSTUDIO
x26
DOUBLEQUEEN
x24
DOUBLEQUEEN
x22
GUESTCORRIDOR
x15
7
8
6
10
HJ
ELECTRICAL
X15A
BALCONY
X35A
BALCONY
X37A
BALCONY
X23A
BALCONY
X25A
BALCONY
X01ABALCONY
X02A
BALCONY
X19A
BALCONY
X21A
201' - 2"
46 sec
127' - 11"
29 sec
127' - 4"
29 sec
164' - 0"
37 sec
L
48' - 9 1/2" DEAD ENDDEAD END22' - 10"45' - 5 1/4" DEAD END1/2 HOUR FIRE RATED WALL
1 HOUR FIRE RATED WALL
2 HOUR FIRE RATED WALL
1/2 HOUR FIRE RATED CORRIDOR
1 HOUR SMOKE BARRIER AT ELEVATOR LOBBY
2 HOUR FIRE RATED SHAFT
THERMAL ENVELOPE BOUNDARY
ACCESSIBLE ROOM - MOBILITY
ACCESSIBLE ROOM - COMMUNICATION FEATURE
CODE LEGEND
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216CODE PLANS
A-001
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
1/16" = 1'-0"11ST FLOOR CODE PLAN
1/16" = 1'-0"2FLOORS 2-5 TYPICAL CODE PLAN
13
4
3
2
KEYNOTES - CODE PLANS
1 CONTINUOUS AIR AND WEATHER BARRIER, TYVEK OR EQUIVALENT. SEE WALL SECTIONS AND DETAILS FOR MORE SPECIFIC LOCATIONS IN SECTION.AIR AND WEATHER BARRIER FORMS PRESSURE BOUNDARY.
2 OWNER TO PROVIDE A MAXIMUM OCCUPANT LOAD SIGN NEAR MAINENTRANCE TO READ "ROOM OCCUPANCY NOT TO EXCEED 115 PEOPLE"
3 OWNER TO PROVIDE A MAXIMUM OCCUPANT LOAD SIGN NEAR MAINENTRANCE TO READ "ROOM OCCUPANCY NOT TO EXCEED 35 PEOPLE"
4 OWNER TO PROVIDE A MAXIMUM OCCUPANT LOAD SIGN NEAR MAINENTRANCE TO READ " ROOM OCCUPANCY NOT TO EXCEED 17 PEOPLE"
5 WEATHERSTRIP EXTERIOR DOORS TO MINIMIZE AIR LEAKAGE
6 PROVIDE DOOR SEALS TO ELIMINATE SMOKE OR AIR PASSAGE.
7 LINEN CHUTE DISCHARGE DOORS MUST BE TOP-HINGED WITH FUSIBLE LINKRELEASE, FIRE/SMOKE SEALS.
8 OUTSIDE AIR INTAKE
9 EXHAUST OPENING
10 ELEVATOR SHAFT RELIEF OPENING IN ROOF
11 CONDITIONED VESTIBULE WITHIN BUILDING THERMAL ENVELOPE.
12 DOOR NOT INTENDED TO BE USED AS BUILDING ENTRANCES (C402.5.7EXCEPTION 1).
13 OWNER TO PROVIDE A MAXIMUM OCCUPANT LOAD SIGN NEAR MAINENTRANCE TO READ "ROOM OCCUPANCY NOT TO EXCEED 48 PEOPLE"
14 OWNER TO PROVIDE A MAXIMUM OCCUPANT LOAD SIGN NEAR MAINENTRANCE TO READ "ROOM OCCUPANCY NOT TO EXCEED 178 PEOPLE"
15 3" ROLLED SEMI-RECESSED FIRE EXTINGUISHER CABINET WITH 10 LBS ABCFIRE EXTINGUISHER.FIRE EXTINGUISHER. ALL FIRE EXTINGUISHERS IN PUBLICAREAS TO BE INSTALLED IN CABINETS. CABINETS TO BE INSTALLED SO THATNO OPERABLE PART IS HIGHER THAN 48" A.F.F.
16 10 LBS ABC FIRE EXTINGUISHER ON HOOK ATTACHED TO WALL
17 2.5 GAL TYPE K FIRE EXTINGUISHER ON HOOK ATTACHED TO WALL
18 2.5 GAL WATER MIST FIRE EXTINGUISHER ON HOOK ATTACHED TO WALL
19 OWNER TO PROVIDE A MAXIMUM OCCUPANT LOAD SIGN NEAR MAINENTRANCE TO READ "ROOM OCCUPANCY NOT TO EXCEED 178 PEOPLE"
20 FIRE SEPARATION DOORS TO BE ON AUTOMATIC CLOSURES ACTIVATED BYFIRE ALARM SYSTEM.
21 WALL MOUNTED SAFETY AND EVACUATION INFORMATION.
22 THIS ELEVATOR CAR SHALL BE LARGE ENOUGH TO ACCOMMODATE ANAMBULANCE STRETCHER. ELEVATOR SHALL RETURN TO FIRST FLOOR INEVENT OF POWER OUTAGE.
23 2 HR FIRE RATED LINEN CHUTE
24 STANDPIPE
25 FIRE RISER AND FLOOR CONTROLS
26 EMERGENCY SHUTOFF BUTTON FOR GAS FIRE PITS AND GAS GRILL.
27 2-WAY COMMUNICATION TO FRONT DESK FROM ELEVATOR LOBBYAREA-OF-REFUGE
A-2
B
A-4
A-2
A-3
A-2
A-2
S-1
A-4A-4
S-1
S-1
S-1
S-1
S-1B
A-2
R-1
S-1
A-4
FIRST FLOOR OCCUPANCY
SPACE NAME AREA OCC. LOAD PEOPLE
ASSEMBLY
A-2
EMPLOYEE ROOM 512 SF 15 NSF 35
FOOD PREP601 SF 200 GSF 4
LOBBY2,657 SF 15 NSF 178
LOBBY SUPPORTSPACES711 SF 50 GSF 15
MEETING ROOM 406 SF FIXED MAX 48
280
A-3
FITNESS801 SF 50 GSF 17
17
A-4
POOL432 SF 50 GSF 9
POOL DECK1,458 SF 15 GSF 98
POOL RESTROOM 80 SF 50 GSF 2
SPLASH PAD272 SF 50 GSF 6
115
BUSINESS
B
LAUNDRY LOUNGE 257 SF 200 GSF 2
OFFICES593 SF 150 GSF 4
6
RESIDENTIAL
R-1
GUEST ROOMS 3,818 SF 200 GSF 20
20
STORAGE/SERVICE
S-1
BOH LAUNDRY 967 SF 100 GSF 10
ELECTRICAL472 SF 300 GSF 2
LINEN STORAGE 148 SF 300 GSF 1
MEETING STORAGE 81 SF 300 GSF 1
OUTDOOR STORAGE 47 SF 300 GSF 1
POOL MEP204 SF 300 GSF 1
WATER HEATERS 361 SF 300 GSF 2
18
Grand total456
R-1
S-1
S-1
2NDFLRONLY
R-1
20
21
6
6
6
7
8
8
20
10
12
11. SEE MECHANICAL FOR INFORMATION ON AIR LEAKAGE TESTINGPROCEDURES AND REQUIREMENTS.
10. COMPLY WITH IBC 2018 SECTION 703.7 REGADING MARKING ANDIDENTIFICATION OF PROTECTED SPACES, WALLS, PARTITIONS OR BARRIERS.THESE SHALL BE EFFECTIVELY AND PERMANENTLY IDENTIFIED WITH SIGNSOR STENCILING IN CONCEALED SPACES AS FOLLOWS:
A. BE LOCATED WITHIN 15 FT OF THE END OF EACH WALL AND AT INTERVALSNOT EXCEEDING 30 FT MEASURED HORIZONTALLY ALONG THE WALL ORPARTITIONSB. INCLUDE LETTERING NOT LESS THAT THAN 3 IN TALL WITH A MINIMUM 3/8IN STROKE IN A CONTRASTING COLOR INCORPORATING THE SUGGESTEDWORKING "FIRE AND/OR SMOKE BARRIER - PROTECT ALL OPENINGS" OR...
9. ALL GYPSUM BOARD INDICATED IN RATED PARTITIONS TO BE 5/8" TYPE XGYPSUM BOARD.
8. ALL RATED PARTITIONS TO EXTEND TO DECK ABOVE WITH A TIGHT SEAL.SEAL ALL PENETRATIONS WITH FIRE STOPPING.
7. SEE DOOR SCHEDULE FOR DOOR FIRE RATINGS, WIDTHS AND PANICHARDWARE LOCATIONS.
6. FIRE EXTINGUISHERS, SMOKE DETECTORS & OTHER EMERGENCY DEVICESTO BE LOCATED PER LOCAL CODE - FIRE EXTINGUISHER LOCATIONS W/INTHE PUBLIC SPACE SHALL BE CONTAINED WITHIN SEMI-RECESSED CABINETS
5. DIRECTIONAL ARROWS INDICATE MEANS OF EGRESS FOR OCCUPANTS. NOTRAVEL DISTANCE EXCEEDS 250 FEET, NO COMMON PATH OF TRAVELEXCEEDS 75 FEET. NO DEAD END CORRIDOR EXCEEDS 50 FEET.
4. REFER TO FIRE PROTECTION, ELECTRICAL AND MECHANICAL DRAWINGS FORSPECIFIC INFORMATION ON FIRE PROTECTION SYSTEMS, FIRE ALARMSYSTEMS, EXIT SIGN LOCATIONS, AND ENERGY EFFICIENCY MEASURESPERTAINING TO MECHANICAL SYSTEMS.
3. ALL RECESSED LIGHTING FIXTURES SHALL BE IC RATED AND HAVE AN AIRLEAKAGE RATING NOT GREATER THAN 2 CFM PER ASTM E283 TEST.
2. SEAL AND CAULK ALL LIGHT FIXTURE HOUSINGS IN EXTERIOR WALLS ORCEILINGS PER MANUFACTURER'S INSTRUCTIONS SO AS TO ELIMINATE AIRLEAKAGE.
1. REFER TO HOMEWOOD SUITES AND HILTON STANDARDS FOR ADDITIONALINFORMATION REGARDING EXTERIOR ENVELOPE REQUIREMENTS.
GENERAL NOTES- CODE
14
19
21 21
212121
21 21 21
21
TYPICAL FLOOR OCCUPANCY
SPACE NAMEAREA OCC. LOAD PEOPLE
RESIDENTIAL
R-1
GUEST ROOMS 17,670 SF 200 GSF 89
89
STORAGE/SERVICE
S-1
LINEN ROOM356 SF300 GSF 2
2
Grand total91
SECOND FLOOR OCCUPANCY
SPACE NAMEAREA OCC. LOAD PEOPLE
RESIDENTIAL
R-1
GUEST ROOMS 17,086 SF 200 GSF 86
86
STORAGE/SERVICE
S-1
ENGINEERING OFFICEAND PBX/MDF356 SF300 GSF 2
LINEN ROOM584 SF300 GSF 2
4
Grand total90
POOL280 PEOPLE 2 44" 44"
FIRST FLOOR 176 PEOPLE 2 44" 44"
CORR. STAIR
LEVELOCCUPANTLOADREQ'DEXITS
REQ'D WIDTH
FIRST FLOOR EGRESS WIDTHS
FIFTH FLOOR 91 PEOPLE 2 44" 44"
FOURTH FLOOR 91 PEOPLE 2 44" 44"
THIRD FLOOR 91 PEOPLE 2 44" 44"
SECOND FLOOR 90 PEOPLE 2 44" 44"
CORR. STAIR
LEVELOCCUPANTLOADREQ'DEXITS
REQ'D WIDTH
UPPER FLOOR EGRESS WIDTHS
0'8' 16'32'
SCALE: 1/16" = 1'-0"
20
66
6
1515
17
16
15
15
16
16
1818
22
22
21 21
212121
21 21 21
21
2121212121
21212121212121
21
21
21
21
21
21
21
21
21
21
23
23
24
15
15
15
15
1515 15 15
25
24
26
26
26
27
16
16
16
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
Revision Schedule
Number Description Date
DDDD
WWWW
5
3
3.1
6.1
2.1
D
C.1
FG
ML.1EC
C
B
B
1
11
8.1
9
4
1.1
A
KNP Q
2
7
8
6
10
H
J
L
EMPLOYEEROOM
110
POOL &SPLASHPAD
101
ELECTRICAL
104
POOL MEP
103
POOLRESTROOM
102
BOHLAUNDRY
105
BOHDRYERS
105A
LINENDISCHARGE& SORTING
107
LINENCHUTE
140
ELEVATORLOBBY
117
ELEV 1
111
ELEV 2
113
WATERHEATER &FIRE
108
STAIR 1
106
LAUNDRYLOUNGE
112
FITNESS
114
MEN'SRESTROOM
116
LINENSTORAGE
109
GUESTSTORAGE
118
WOMEN'SRESTROOM
115
LOBBY
121
FOOD PREP
123
PUBLICCORRIDOR
121A
GUESTCORRIDOR
139
EFFICIENCY
129
EFFICIENCY
131
EFFICIENCY
133
DOUBLEQUEEN
135
KINGSTUDIOADA-M-T
138
DOUBLEQUEEN
136
EFFICIENCY
134
STAIR 2
132
KINGSTUDIO
130
OPENOFFICE
124
GM OFFICE
125VESTIBULE
122
MEETINGROOM
120
MEETINGSTORAGE
119
SALESOFFICE
126
OWNER'SOFFICE
127
ELECTRICAL
128
COURTYARDSTORAGE
141
VESTIBULE
139A
PUBLICCORRIDOR
100
VESTIBULE
100A
EMP RRADA
110AEMP RR
110B
KINGSTUDIO
137
LANAI
137A
LANAI
135A
138 - BATHTUB
133
5
3
3.1
6.1
2.1
D
C.1FGML.1EC
C
B
B
1
8.1
9
4
1.1
A
KNP Q
2
7
8
6
10
HJ
L
KING1-BEDROOMADA-M-T
x01
CONNECTINGCORRIDOR
x00
KING1-BEDROOM
x02
KINGSTUDIO
x04
EFFICIENCYENLARGED
x03
EFFICIENCY
x05
EFFICIENCY
x07
LINENS &HOUSEKEEPING
x09
EFFICIENCY
x08
DOUBLEQUEEN
x10
STAIR 1
x06
DOUBLEQUEENENLARGED
x12
KINGSTUDIO
x14KINGSTUDIO
x16
KINGSTUDIO
x18
KINGSTUDIO
x20
ELEV 1
111
ELEV 2
113
ELEVATORLOBBY
x17
KINGSTUDIO
x19
KINGSTUDIO
x21
KINGSTUDIO
x23
KINGSTUDIO
x25
EFFICIENCY
x27
EFFICIENCY
x29
EFFICIENCY
x31
EFFICIENCY
x33DOUBLEQUEEN
x35
KINGSTUDIO
x37
KINGSTUDIOADA-M-RI
x38
DOUBLEQUEEN
x36
EFFICIENCY
x34
STAIR 2
x32
KINGSTUDIO
x30
EFFICIENCY
x28
KINGSTUDIO
x26
DOUBLEQUEEN
x24
DOUBLEQUEEN
x22
GUESTCORRIDOR
x15
ELECTRICAL
X15A
BALCONY
X35A
BALCONY
X37A
BALCONY
X23A
BALCONY
X25A
BALCONY
X01ABALCONY
X02A
BALCONY
X19A
BALCONY
X21A
FLOOR 10' - 0"
FLOOR 216' - 0"
FLOOR 327' - 0"
FLOOR 438' - 0"
FLOOR 549' - 0"
MAIN ROOF61' - 2"
LOW PARAPET63' - 10"
MIDDLE PARAPET65' - 10"
SITE-0' - 6"
9786 10
EFFICIENCY
131
EFFICIENCY
231
EFFICIENCY
331
EFFICIENCY
431
EFFICIENCY
531
ROOFACCESS
539STAIR 2
532
STAIR 2
432
STAIR 2
332
STAIR 2
232
STAIR 2
132 11' - 0"11' - 0"11' - 0"16' - 0"12' - 2"1/2 HOUR FIRE RATED WALL
1 HOUR FIRE RATED WALL
2 HOUR FIRE RATED WALL
1/2 HOUR FIRE RATED CORRIDOR
1 HOUR SMOKE BARRIER AT ELEVATOR LOBBY
2 HOUR FIRE RATED SHAFT
THERMAL ENVELOPE BOUNDARY
ACCESSIBLE ROOM - MOBILITY
ACCESSIBLE ROOM - COMMUNICATION FEATURE
CODE LEGEND
1
9
10
11
11
11
1/16" = 1'-0"11ST FLOOR ENVELOPE & ACCESSIBILITY PLAN
1/16" = 1'-0"2FLOORS 2-5 TYPICAL ENVELOPE & ACCESSIBILITY PLAN
1/16" = 1'-0"3 THERMAL ENVELOPE CROSS SECTION
0'4' 8'16'
SCALE: 1/8" = 1'-0"
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216BUILDING ENVELOPE &ACCESIBILITY PLANS
A-002
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
5
5
5
5
5
5
5
5
5
1
1
6
66
6
6
6
9
8
8
KEYNOTES - CODE PLANS
1 CONTINUOUS AIR AND WEATHER BARRIER, TYVEK OR EQUIVALENT. SEE WALL SECTIONS AND DETAILS FOR MORE SPECIFIC LOCATIONS IN SECTION.AIR AND WEATHER BARRIER FORMS PRESSURE BOUNDARY.
2 OWNER TO PROVIDE A MAXIMUM OCCUPANT LOAD SIGN NEAR MAINENTRANCE TO READ "ROOM OCCUPANCY NOT TO EXCEED 115 PEOPLE"
3 OWNER TO PROVIDE A MAXIMUM OCCUPANT LOAD SIGN NEAR MAINENTRANCE TO READ "ROOM OCCUPANCY NOT TO EXCEED 35 PEOPLE"
4 OWNER TO PROVIDE A MAXIMUM OCCUPANT LOAD SIGN NEAR MAINENTRANCE TO READ " ROOM OCCUPANCY NOT TO EXCEED 17 PEOPLE"
5 WEATHERSTRIP EXTERIOR DOORS TO MINIMIZE AIR LEAKAGE
6 PROVIDE DOOR SEALS TO ELIMINATE SMOKE OR AIR PASSAGE.
7 LINEN CHUTE DISCHARGE DOORS MUST BE TOP-HINGED WITH FUSIBLE LINKRELEASE, FIRE/SMOKE SEALS.
8 OUTSIDE AIR INTAKE
9 EXHAUST OPENING
10 ELEVATOR SHAFT RELIEF OPENING IN ROOF
11 CONDITIONED VESTIBULE WITHIN BUILDING THERMAL ENVELOPE.
12 DOOR NOT INTENDED TO BE USED AS BUILDING ENTRANCES (C402.5.7EXCEPTION 1).
13 OWNER TO PROVIDE A MAXIMUM OCCUPANT LOAD SIGN NEAR MAINENTRANCE TO READ "ROOM OCCUPANCY NOT TO EXCEED 48 PEOPLE"
14 OWNER TO PROVIDE A MAXIMUM OCCUPANT LOAD SIGN NEAR MAINENTRANCE TO READ "ROOM OCCUPANCY NOT TO EXCEED 178 PEOPLE"
15 3" ROLLED SEMI-RECESSED FIRE EXTINGUISHER CABINET WITH 10 LBS ABCFIRE EXTINGUISHER.FIRE EXTINGUISHER. ALL FIRE EXTINGUISHERS IN PUBLICAREAS TO BE INSTALLED IN CABINETS. CABINETS TO BE INSTALLED SO THATNO OPERABLE PART IS HIGHER THAN 48" A.F.F.
16 10 LBS ABC FIRE EXTINGUISHER ON HOOK ATTACHED TO WALL
17 2.5 GAL TYPE K FIRE EXTINGUISHER ON HOOK ATTACHED TO WALL
18 2.5 GAL WATER MIST FIRE EXTINGUISHER ON HOOK ATTACHED TO WALL
19 OWNER TO PROVIDE A MAXIMUM OCCUPANT LOAD SIGN NEAR MAINENTRANCE TO READ "ROOM OCCUPANCY NOT TO EXCEED 178 PEOPLE"
20 FIRE SEPARATION DOORS TO BE ON AUTOMATIC CLOSURES ACTIVATED BYFIRE ALARM SYSTEM.
21 WALL MOUNTED SAFETY AND EVACUATION INFORMATION.
22 THIS ELEVATOR CAR SHALL BE LARGE ENOUGH TO ACCOMMODATE ANAMBULANCE STRETCHER. ELEVATOR SHALL RETURN TO FIRST FLOOR INEVENT OF POWER OUTAGE.
23 2 HR FIRE RATED LINEN CHUTE
24 STANDPIPE
25 FIRE RISER AND FLOOR CONTROLS
26 EMERGENCY SHUTOFF BUTTON FOR GAS FIRE PITS AND GAS GRILL.
27 2-WAY COMMUNICATION TO FRONT DESK FROM ELEVATOR LOBBYAREA-OF-REFUGE
238 - BATHTUB338 - ROLL-IN SHOWER
301 - BATHTUB
503 - BATHTUB403 - ROLL-IN SHOWER
512 - BATHTUB
238
303
519325435508
404
202
530428
322
11. SEE MECHANICAL FOR INFORMATION ON AIR LEAKAGE TESTINGPROCEDURES AND REQUIREMENTS.
10. COMPLY WITH IBC 2018 SECTION 703.7 REGADING MARKING ANDIDENTIFICATION OF PROTECTED SPACES, WALLS, PARTITIONS OR BARRIERS.THESE SHALL BE EFFECTIVELY AND PERMANENTLY IDENTIFIED WITH SIGNSOR STENCILING IN CONCEALED SPACES AS FOLLOWS:
A. BE LOCATED WITHIN 15 FT OF THE END OF EACH WALL AND AT INTERVALSNOT EXCEEDING 30 FT MEASURED HORIZONTALLY ALONG THE WALL ORPARTITIONSB. INCLUDE LETTERING NOT LESS THAT THAN 3 IN TALL WITH A MINIMUM 3/8IN STROKE IN A CONTRASTING COLOR INCORPORATING THE SUGGESTEDWORKING "FIRE AND/OR SMOKE BARRIER - PROTECT ALL OPENINGS" OR...
9. ALL GYPSUM BOARD INDICATED IN RATED PARTITIONS TO BE 5/8" TYPE XGYPSUM BOARD.
8. ALL RATED PARTITIONS TO EXTEND TO DECK ABOVE WITH A TIGHT SEAL.SEAL ALL PENETRATIONS WITH FIRE STOPPING.
7. SEE DOOR SCHEDULE FOR DOOR FIRE RATINGS, WIDTHS AND PANICHARDWARE LOCATIONS.
6. FIRE EXTINGUISHERS, SMOKE DETECTORS & OTHER EMERGENCY DEVICESTO BE LOCATED PER LOCAL CODE - FIRE EXTINGUISHER LOCATIONS W/INTHE PUBLIC SPACE SHALL BE CONTAINED WITHIN SEMI-RECESSED CABINETS
5. DIRECTIONAL ARROWS INDICATE MEANS OF EGRESS FOR OCCUPANTS. NOTRAVEL DISTANCE EXCEEDS 250 FEET, NO COMMON PATH OF TRAVELEXCEEDS 75 FEET. NO DEAD END CORRIDOR EXCEEDS 50 FEET.
4. REFER TO FIRE PROTECTION, ELECTRICAL AND MECHANICAL DRAWINGS FORSPECIFIC INFORMATION ON FIRE PROTECTION SYSTEMS, FIRE ALARMSYSTEMS, EXIT SIGN LOCATIONS, AND ENERGY EFFICIENCY MEASURESPERTAINING TO MECHANICAL SYSTEMS.
3. ALL RECESSED LIGHTING FIXTURES SHALL BE IC RATED AND HAVE AN AIRLEAKAGE RATING NOT GREATER THAN 2 CFM PER ASTM E283 TEST.
2. SEAL AND CAULK ALL LIGHT FIXTURE HOUSINGS IN EXTERIOR WALLS ORCEILINGS PER MANUFACTURER'S INSTRUCTIONS SO AS TO ELIMINATE AIRLEAKAGE.
1. REFER TO HOMEWOOD SUITES AND HILTON STANDARDS FOR ADDITIONALINFORMATION REGARDING EXTERIOR ENVELOPE REQUIREMENTS.
GENERAL NOTES- CODE
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
Revision Schedule
Number Description Date
D
F
1
11
EAST CARLISLE
A
V
E
N
U
EEAST M
IRABEAU PARKWAY
A-402
1
A-4011
N67°
3
0
'
1
7
"
W
399.9
6
'
N89° 44'32" W
55.93'
R: 4
9
2
.
4
7
'
L: 14
4
.
7
4
'R: 726.41'L: 487.82'N22° 44'41" E345.57'S82° 44'03" E
160.47'
L: 148.59'
R: 550.00'
3.30'
155.07'
105.40'R: 30.00'L: 44.98'6' - 9 1/2"CENT
E
N
N
I
A
L
T
R
A
I
L
SPOK
A
N
E
R
I
V
E
R
145' - 1"9A
Q
6
H
A-4031
A-407
1MIN. 20' - 0"A-4012
HOMEWOOD SUITES BY HILTON132 KEYS
10' - 0"
10' - 0"10' - 0"18' - 0"36' - 0"8' - 0"
8' - 0"5' - 0"
8' - 0"
9' - 0"9' - 0"9' - 0"18' - 0"10' - 0"1
2
3
4
5
6
7
8
9
10
11
12
13
A14
15
16
17
18
C19
C20
C21
C22
C23
C24
C25
C26
C27
C28
C29
C30
C31
C32
C33
C34
C35
C36
C37
C38
C39
C40
C41
C42
43
44
45
46
48
47
49
50
51
52
53
54
55
56
57
C58C59C60C61C62C63C64C65C66
6768697071727374757677
86
R78
87
79
R80
R81
R82
R83
84
85
88
89
90
91
92
93
989694
999795
100
101
102
103
R104
R105
R106
R107
R108
R109
110112114116118119121
111113115117120122123124
125126128130
127129
132134136138140142
131133135137139141
A143A144A145A146A147
18' - 0"18' - 0"18' - 0"9' - 0"
9' - 0"18' - 0"30' - 0"
30
'
-
0
"36' - 0"29' - 3 1/4"R 30' - 0"R 30' - 0"
R
4
8
'
-
0
"
R 48' -
0"
R 15' - 0"R 1
5
'
-
0
"
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216OVERALL SITE PLAN
A-010
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
1" = 30'-0"1ARCHITECTURAL SITE PLAN
PARKING NOTES
COMPACT STALLS: 33 STALLS PROVIDEDSIZE: 8'-0" X 18'-0" PER SPOKANE CODE (BRAND STANDARDS DO NOT SPECIFY COMPACT SIZE)MAX 25% STALLS ALLOWED TO BE COMPACT PER BRAND STANDARDS (147 * 0.25 = 37 STALLS)STALLS DESIGNATED TO CONTIGUOUS AREAS PER SPOKANE CODE
STANDARD STALLS: 108 STALLS PROVIDEDSIZE 9'-0" X 18'-0" PER BRAND STANDARDS
ADA STALLS: 6 STALLS PROVIDED6 REQUIRED PER SPOKANE CODE UP TO 150 STALLSADA STANDARD: 5 STALLS PROVIDED [SIZE: 8'-0" X 18'-0" (ADAAG) + 5'-0" ACCESS AISLE (ADAAG)]ADA VAN: 1 STALL PROVIDED [SIZE: 8'-0" X 18''-0" + 8'-0" ACCESS AISLE (ADAAG)]
TOTAL STALLS: 147 STALLS PROVIDED
SITE NOTES
BIKE RACKS: 4 SETS OF 2 PROVIDED3 SETS OF BIKE STORAGE FOR 2 BIKES EACH FOR 100-500 SPACES PER SPOKANE CODE
FIRE LANES: (INFORMATION PROVIDED BY AHJ FIRE REVIEWER)NO FIRE LANE REQUIRED ON NORTH SIDE OF BUILDING BECAUSE BUILDING WILL BE FULLY SPRINKLERED PER NFPA 13.FIRE LANES MUST BE 26' WIDE WITH FULL CLEAR HEIGHT FOR AERIAL ACCESS AROUND BUILDING.
ELECTRIC VEHICLE READY STALLS: 16 EV-READY STALLS PROVIDED (INCLUDING 1 ADA VAN ACCESSIBLE)10% STALLS REQUIRED TO BE EV-READY PER WAC CODE (147 * 0.10 = 15 STALLS, INCLUDING 1 ADA STALL)
ELECTRIC VEHICLE CHARGING STATIONS: 2 STALLS WITH EV STATIONS PROVIDED (INCLUDING 1 ADA)MINIMUM 2 STALLS REQUIRED TO HAVE EV STATIONS INSTALLED PER HILTON BRAND STANDARDS
0'15' 30'60'
SCALE: 1" = 30'-0"
KEYNOTES - SITE PLAN
1 PAD-MOUNTED TRANSFORMER. SEE ELECTRICAL. PROVIDE DENSE LANDSCAPE SCREENING AND/OR FENCING ATTRANSFORMER PAD PER LOCAL UTILITY COMPANY STANDARDS.
2 ACCESSIBLE PASSENGER DROP OFF AREA W/ ADJACENT CLEAR ACCESS AISLE. DROP OFF AND ACCESS AISLESHALL BE AT THE SAME LEVEL AND SHALL HAVE A SLOPE NOT TO EXCEED 1:48 (1:64 RECOMMENDED). DRIVE AISLESSHALL RAMP UP TO LEVEL OF WALK AT DROP-OFF AREA.
3 OUTDOOR KITCHEN
4 EMERGENCY GENERATOR. SEE ELECTRICAL. PROVIDE DENSE LANDSCAPE SCREENING AT GENERATORENCLOSURE.
5 LINE OF PORTE COCHERE AVOVE, ALIGN WITH EDGE OF CONCRETE APRON
6 FLAGPOLE, 25' TALL WITH UPLIGHT IN GROUND. FLAGS TO BE DETERMINED BY OWNER (EITHER UNITED STATESONLY, OR UNITED STATES, WASHINGTON STATE AND HOMEWOOD SUITES).
7 ILLUMINATED HOMEWOOD SUITES MONUMENT SIGN
8 CONTINUOUS 6" CONCRETE CURB, TYP.
9 EXTERIOR STORAGE SHED
10 DUMPSTER ENCLOSURE FOR TRASH AND RECYCLING WITH GATE AND LOCKING HARDWARE
11 4' HIGH ORNAMENTAL IRON FENCE
12 3' HIGH ORNAMENTAL IRON FENCE ON RETAINING WALL EXTENDING 1' ABOVE GRADE (MIN. 3' - 6" ABOVE GRADE ATALL LOCATIONS WITH A DROP GREATER THAN 30").
13 ILLUMINATED HOMEWOOD SUITES DRIVEWAY SIGN
14 EV READY STALLS. PROVIDE CONCRETE WHEEL STOP.
15 EV CHARGING STALLS. EV CHARGING STATIONS MUST HAVE BOTH UNIVERSAL AND PROPRIETARY CHARGINGCAPABILITITES AND AT LEAST LEVEL 2 CHARGING (AT MINIMUM). PROVIDE CONCRETE WHEEL STOP. SIGNAGE MUSTBE PROVIDED AT EACH STALL STATING, "ELECTRIC VEHICLE PARKING ONLY WHILE CHARGING"
16 COMPACT SPACES. 8' WIDE BY 18' LONG.
17 ACCESSIBLE PARKING SPACE - 8' WIDE BY 18' LONG AND 5' WIDE AISLE FOR ACCESSIBLE PARKING SPACES.PROVIDE SIGNAGE AS REQUIRED. PROVIDE CONCRETE WHEEL STOP AT ACCESSIBLE SPACES.
18 ACCESSIBLE PARKING SPACE - VAN ACCESSIBLE AND EV CHARGING STATION. 8' WIDE BY 20' LONG AND 8' WIDEAISLE FOR VAN ACCESSIBLE PARKING STALL. PROVIDE SIGNAGE FOR ACCESSIBLE PARKING STALL AS REQUIRED.PROVIDE SIGNAGE INDICATING VAN ACCESSIBLE STALL. PROVIDE SIGN THAT READS, "ELECTRIC VEHICLE PARKINGPREFERRED" BELOW ACCESSIBILITY SIGNS. PROVIDE CONCRETE WHEEL STOP. ANY VEHICLE WITH AN ACCESSIBLEPARKING PERMIT MUST BE ALLOWED TO PARK IN THIS SPACE.
19 SEMI-ENCLOSED SMOKING SHELTER GREATER THAN 25' FROM WINDOWS, DOORS OR AIR INTAKE VENTS. PROVIDEBENCH AT ADA ACCESSIBLE HEIGHT, ASH RECEPTACLE AND TRASH CAN. SCREEN WITH LANDSCAPING WHEREPOSSIBLE.
20 ACCESSIBLE CURB RAMP TO MEET ALL ACCESSIBILITY REQUIREMENTS. MAXIMUM SLOPE OF RUN 1:12, MAXIMUMCROSS SLOPE OF 2%, PROVIDE DETECTABLE WARNING EXTENDING MIN. 2' FROM BACK OF CURB.
21 12' X 30' LOADING ZONE. PROVIDE SIGNAGE AS REQUIRED.
22 26' WIDE FIRE LANE. NO PARKING. PROVIDE SIGNAGE AS REQUIRED BY AHJ.
23 KNOX BOX
24 BOLLARDS AND CHAIN. KEY TO CHAIN PADLOCK IN KNOX BOX.
25 ACCESSIBLE ROUTE. MARK WHERE ROUTE CROSSES VEHICULAR TRAFFIC.
26 ASPHALT PAVING. PROVIDE POSITIVE DRAINAGE AWAY FROM BUILDING.
27 RV, BUS OR OVERSIZED VEHICLE PARKING WHEN REQUIRED. 9'WX36' COMBINED.
28 PET EXERCISE AND RELIEF AREA. AREA MUST BE CLEARLY DESIGNATED WITH SIGNAGE.
29 STAMPED, COLORED CONCRETE APRON AND COURTYARD
30 CANOPY ABOVE
31 40'x100' WEDDING AREA, GREATER THAN 20' FROM BUILDING WALLS. OWNER TO SECURE EVENT PERMIT WITHSPOKANE VALLEY FIRE DEPARTMENT PRIOR TO EVENTS.
32 MAINTAIN APPROPRIATE SIGHT LINES AT DRIVEWAY ENTRANCES AND EXITS.
33 ALL EQUIPMENT (INCLUDING DRYER VENTS) MUST BE SCREENED WITH LANDSCAPING OR OTHER MEANS.
34 ACCESSIBLE PARALLEL CURB RAMP TO MEET ALL ACCESSIBILITY REQUIREMENTS. MAXIMUM SLOPE OF RUN 1:12,MAXIMUM CROSS SLOPE OF 2%, PROVIDE DETECTABLE WARNING EXTENDING MIN. 2' FROM BACK OF CURB. SEECIVIL FOR ELEVATIONS.
35 GREASE TRAP. SEE PLUMBING
36 DRAINAGE POND
37 EXISTING FLUSH UTILITY ACCESS BOX
38 PROPERTY LINE
39 LANDSCAPE AREA. SEE LANDSCAPE PLANS, TYP.
40 SITE LIGHT- SEE ELECTRICAL
41 PET AREA SITE LIGHT- SEE ELECTRICAL
42 HEADLIGHT SCREENING VIA EVERGREEN LANDSCAPING ALONG ENTIRE LENGTH OF PARKING LOT FACINGMIRABEAU PARKWAY AND EAST CARLISLE AVENUE WHERE CARS ARE PARKING FACING STREET. SEE LANDSCAPE.
43 RV, BUS OR OVERSIZED VEHICLE PARKING WHEN REQUIRED. 10'WX36' COMBINED.
44 RESERVED PARKING FOR DIAMOND MEMBERS. SEE HILTON SIGNAGE GUIDE FOR SIGN REQUIREMENTS.
45 UTILITY EASEMENT
46 5' WIDE SIDEWALK. SEE CIVIL FOR DETAILS AND ELEVATIONS.
47 6' WIDE SIDEWALK. SEE CIVIL FOR DETAILS AND ELEVATIONS.
48 CONCRETE WHEEL STOPS
49 EV CHARGING STATION AT ACCESSIBLE/STANDARD SPACE COMBINATION. SCREEN AND ANY CONTROLS MUST FACETHE SIDEWALK. ALL CONTROLS MUST BE BELOW 48" A.F.F.
50 EXISTING UTILITY CONNECTION
51 EXISTING FIRE HYDRANT
52 EXISTING TRANSFORMER
1
4
6
7
8
9
10
28
13
15
13
21
22
34
22
22
22
22
23
24
25
25
26
434343
19
3
30
30
30
31
272727
32
32
33
33
25
25
11
12
12
SITE NOTES
36
36
18
20
19
8. CATCH BASINS ARE TO BE PLACED SO AS NOT TO INTERFERE WITH DESIGNATED ACCESSIBLE ROUTES.
7. 10% OF NON-PAVED, NON-COVERED AREA OF PROJECT SITE TO BE LANDSCAPED.
6. INSTALL ACCENT PLANTINGS OF ANNUALS AND PERENNIALS AT MAIN ENTRANCE, BUILDING ENTRY, AND SIGNAGEAREAS, AND BACKYARD.
5. SOD ALL AREAS NOT WITHIN PLANTING BEDS.
4. IRRIGATE ALL LANDSCAPED AREAS WITH AUTOMATIC UNDERGROUND SPRINKLER SYSTEM.
3. BUILDING UPLIGHTING SHALL NOT BE OBSTRUCTED BY LANDSCAPE PLANTINGS.
2. REFER TO HILTON SIGNAGE STANDARDS, BRAND STANDARDS AND HILTON marKIT FOR ADDITIONAL INFORMATIONAND PRECISE SIGNAGE REQUIREMENTS. ELECTRICAL FOR BUILDING SIGNAGE AND MONUMENT SIGNAGE SHALLBE PROVIDED AND CONNECTED BY THE CONTRACTOR.
1. COORDINATE LIGHTING LOCATIONS WITH LANDSCAPE PLANTINGS
GENERAL NOTES- SITE
38
40
48TYP.
39
40
40
40
40
39
39
40
40
40
40
41
41
42
42
4444444444
14
14
34
42
45
45
3939
46
46
46
47
47
46
3939
39
39
39
39
39
39
39
39
39
39
40
39
39
39
40
40
48TYP.
2
2
48TYP.49
50
5052
37
51
14
14
14
14
14
14
14
14
14
14
14
14
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
161616161616161616
35
3940
40
1717171717
2
39
46
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
REVISION SCHEDULE
# DESCRIPTION DATE
2 ADDENDUM 2 6/21/2024
DN
DDDD
WWWW
UP
UP
A-2012
A-202
A-202
A-201
1
2
1
MEN'SRESTROOM
116
WOMEN'SRESTROOM
115MEETING
STORAGE
119
MEETINGROOM
120
GUEST
STORAGE
118FITNESS
114
VESTIBULE
122
COURTYARDSTORAGE
141
GUEST
CORRIDOR
139
LOBBY
121
LAUNDRYLOUNGE
112
EMPLOYEEROOM
110
WATER
HEATER & FIRE
108
EMP RR ADA
110AEMP RR
110B
POOL &SPLASH PAD
101
POOLRESTROOM
102
ELECTRICAL
104
STAIR 1
106
PUBLIC
CORRIDOR
100
BOH LAUNDRY
105
LINENSTORAGE
109
HOUSEKEEPINGOFFICE
109A
LINENDISCHARGE &SORTING
107
POOL MEP
103
5
3
3.1
6.1
2.1
D
C.1
FG
ML.1E
1
A-301
FOOD PREP
123
A-420
4
A-4144
C
C
B
B
1
ELEVATORLOBBY117ELEV 2
113
ELEV 1
111
LINEN CHUTE
140
STAIR 2
132
ELECTRICAL
139B
KING STUDIOADA-M-T
138
LANAI
135A
LANAI
137A
2
A-302
3
A-302
11165' - 8 1/2"A-1221
A-121
1
PUBLICCORRIDOR
121A
VESTIBULE
139A
VESTIBULE
100A
ELECTRICAL
128
OWNER'SOFFICE
127
SALES OFFICE
126
GM OFFICE
125
OPEN OFFICE
124
BOH DRYERS
105A
1
A-302
8.1
9
4
1.1
A
A
K N P Q
2
ICE/WATER
118A
7
8
6
10
H
J
2
A-301
L
EFFICIENCY
129
KING STUDIO
130
EFFICIENCY
131
EFFICIENCY
134
EFFICIENCY
133
DOUBLE
QUEEN
136
DOUBLE
QUEEN
135 KING STUDIO
137
249' - 11"60' - 3 1/2"65' - 1 1/2"184' - 9 1/2"
ADA MOBILITY ROOM
ADA COMMUNICATION FEATURES ROOM
ADA SYMBOL LEGEND
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216OVERALL 1ST FLOORPLAN
A-101
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
3/32" = 1'-0"11ST FLOOR PLAN
0'6' 12'24'
SCALE: 3/32" = 1'-0"
5. SEE STRUCTURAL TO VERIFY LOCATIONS OF ALL SHEAR WALLS. SEE ELEVATIONS TO VERIFY EXTERIOR FINISHMATERIAL AND COLOR.
4. PROVIDE AN ACCESSIBLE ROUTE AND COMPLIANT WHEELCHAIR LOCATIONS IN EACH OF THE PUBLIC SPACESPROVIDED FOR GUEST USE.
3. BOTH VISUAL AND NOTIFICATION DEVICES SHALL BE PROVIDED IN PUBLIC AND COMMON AREAS. THE SYSTEMMUST BE DESIGNED TO BE ABLE TO BE INTEGRATED INTO EMPLOYEE WORK SPACES AND MUST COMPLY WITHNFPA 72 AND STATE, LOCAL AND FEDERAL REGULATIONS. DEVICES MUST BE LOCATED SO THE LIGHT IS VISIBLE INEACH REQUIRED SPACE.
2. ALL WALLS IN BATH SHALL BE MOISTURE RESISTANT GYPSUM BOARD. BATH CEILING SHALL BE EXTERIORGYPSUM BOARD.
1. REFER TO HOMEWOOD STANDARDS FOR FLOORING REQUIREMENTS IN EACH AREA.
GENERAL NOTES- FLOOR PLANS
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
Revision Schedule
Number Description Date
W/DW/DDN
UP
DN
UP
A-2012
A-202
A-202
A-201
1
2
1
5
3
3.1
6.1
2.1
D
C.1
F G
ML.1
ENGINEERINGOFFICE &STORAGE
207
E
1
A-301
PBX/MDF
207A
A-4151
A-4201
A-420
2
A-414
1
A-4111A-4142
A-4221
A-4191A-417
1
C
C
B
B
1
KING STUDIO
237
KING STUDIOADA-M-T
238DOUBLEQUEEN
236
DOUBLEQUEEN
235
EFFICIENCY
233
KING1-BEDROOM
202
KING
1-BEDROOMENLARGED
201
DOUBLEQUEEN
210
DOUBLEQUEEN
ENLARGED
212
KING STUDIO
214
PANELS
209A
ELEVATORLOBBY217EFFICIENCYENLARGED
203
CONNECTINGCORRIDOR
200
EFFICIENCY
229EFFICIENCY
227
EFFICIENCY
208
EFFICIENCY
205
KING STUDIO
220
KING STUDIO
218
KING STUDIO
216 KING STUDIO
226
KING STUDIO
219
KING STUDIO
221
KING STUDIO
223
KING STUDIO
225
DOUBLEQUEEN
224
DOUBLEQUEEN
222
GUESTCORRIDOR
215
EFFICIENCY
228
EFFICIENCY
231
EFFICIENCY
234
KING STUDIO
230
ELEV 2
113
ELEV 1
111
LINEN CHUTE
140
STAIR 1
206
STAIR 2
232
BALCONY
201ABALCONY
202A
BALCONY
218A
BALCONY
221A
BALCONY
223A
BALCONY
225A
BALCONY
235A
BALCONY
237A
2
A-302
3
A-302
11165' - 8 1/2"A-1241
A-1231
LINENS &HOUSEKEEPING
209
IDF
209B
DAC
209C
1
A-302
8.1
9
4
1.1
A
K N P Q
2
3
A-505
7
8
6
10
H
J
2
A-301
1
A-505
L
EQEQ
KING STUDIO
204
ELECTRICAL
215A
P3.3
P3.1
P3.2
P3.2
P3.3
P4.2
P1.1
P3.2
P3.1
P3.1
XS1
XE1/2
P9.1
XE1/2
XE3
XE1/2
XD2
XE1/2
XD2
XS1 XE1/2
P5.1
P3.2 P3.2
P3.2 P3.2
P3.1 P3.1 P3.2 P3.1P3.2
XE1/2
XE1/2
XE1/2
XE1/2
XE1/2
XE3P3.1
XE1/2
P3.2P4.1P4.3P3.1P3.2P3.2P3.2P3.2P3.2P3.1P3.2P3.1 XE1/2XE3
XE3
XS1XE1/2XS1
P3.1
P5.1P3.2
XE1/2
XE1/2 XE1/2
XE1/2
ADA MOBILITY ROOM
ADA COMMUNICATION FEATURES ROOM
ADA SYMBOL LEGEND
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216OVERALL 2ND FLOORPLAN
A-102
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
3/32" = 1'-0"12ND FLOOR PLAN
0'6' 12'24'
SCALE: 3/32" = 1'-0"
5. SEE STRUCTURAL TO VERIFY LOCATIONS OF ALL SHEAR WALLS. SEE ELEVATIONS TO VERIFY EXTERIOR FINISHMATERIAL AND COLOR.
4. PROVIDE AN ACCESSIBLE ROUTE AND COMPLIANT WHEELCHAIR LOCATIONS IN EACH OF THE PUBLIC SPACESPROVIDED FOR GUEST USE.
3. BOTH VISUAL AND NOTIFICATION DEVICES SHALL BE PROVIDED IN PUBLIC AND COMMON AREAS. THE SYSTEMMUST BE DESIGNED TO BE ABLE TO BE INTEGRATED INTO EMPLOYEE WORK SPACES AND MUST COMPLY WITHNFPA 72 AND STATE, LOCAL AND FEDERAL REGULATIONS. DEVICES MUST BE LOCATED SO THE LIGHT IS VISIBLE INEACH REQUIRED SPACE.
2. ALL WALLS IN BATH SHALL BE MOISTURE RESISTANT GYPSUM BOARD. BATH CEILING SHALL BE EXTERIORGYPSUM BOARD.
1. REFER TO HOMEWOOD STANDARDS FOR FLOORING REQUIREMENTS IN EACH AREA.
GENERAL NOTES- FLOOR PLANS
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
Revision Schedule
Number Description Date
W/DDN
UPWD
DN UP
A-2012
A-202
A-202
A-201
1
2
1
5
3
3.1
6.1
2.1
D
C.1
FG
ML.1E
1
A-301
A-418
1
A-413
1
C
C
B
B
1
KING STUDIO
ADA-M-RI
338
KING1-BEDROOM
302
KING1-BEDROOM
ADA-M-T
301
DOUBLE
QUEEN
310
DOUBLEQUEENENLARGED
312
KING STUDIO
314
EFFICIENCY
307
PANELS
309A
ELEVATORLOBBY317LINENS &
HOUSEKEEPING
309
EFFICIENCYENLARGED
303
CONNECTINGCORRIDOR
300
EFFICIENCY
308
EFFICIENCY
305
GUESTCORRIDOR
315
ELEV 2
113
ELEV 1
111
LINEN CHUTE
140
BALCONY
301ABALCONY
302A
BALCONY
319A
BALCONY
321A
BALCONY
323A
BALCONY
325A
BALCONY
335A
BALCONY
337A
STAIR 1
306
STAIR 2
332
IDF
309B
ELECTRICAL
315A
2
A-302
3
A-302
DAC
309C
1
A-302
8.1
9
4
1.1
A
A
K N P Q
2
7
8
6
10
H
J
2
A-301
L
KING STUDIO
320
KING STUDIO
319
KING STUDIO
321
DOUBLE
QUEEN
322
KING STUDIO
323
DOUBLE
QUEEN
324
KING STUDIO
326
KING STUDIO
325
EFFICIENCY
327
EFFICIENCY
328
EFFICIENCY
329
KING STUDIO
330
EFFICIENCY
331
EFFICIENCY
333
EFFICIENCY
334
DOUBLEQUEEN
336
DOUBLEQUEEN
335 KING STUDIO
337
KING STUDIO
318
KING STUDIO
316
KING STUDIO
304
P3.3
P3.1
P3.1
P3.2
P3.3
P4.2
P4.2
P3.2
P3.1
P3.1
XE1/2
XE1/2
XE1/2
XE1/2
XE1/2
XE1/2
XE1/2
XE1/2
XE1/2
XD2
XE1/2
XD2
XE1/2 XE1/2
P5.1
P3.2P3.2
P3.2 P3.2
P3.1 P3.1 P3.2 P3.1P3.2
XE1/2
XE1/2
XE1/2
XE1/2
XE1/2
XE1/2P3.1
XE1/2
P3.2P4.1P4.3P3.1P3.2P3.2P3.2P3.2P3.2P3.1P3.2P3.1 XE1/2XE1/2
XE1/2
XE1/2XW1XE1/2XE1/2
P3.1
P5.1P3.2
6' - 0"19' - 7 1/4" 4' - 7 1/2"6' - 1 1/4" 8' - 8 3/4" 15' - 2 3/4" 3' - 11 1/4" 15' - 0 1/2" 9' - 3"19' - 2 3/4"25' - 8 3/4"133' - 6"30' - 6 3/4"5' - 10 1/4"28' - 8 1/2"
65' - 1 1/2"18' - 11 3/4"15' - 0 3/4"15' - 7"27' - 9 1/4"77' - 5"6' - 0"24' - 2 3/4"6' - 1 1/4"23' - 11 3/4"60' - 3 1/2"30' - 6 3/4"5' - 10 1/4" 19' - 6 1/2"19' - 1"19' - 0 3/4"19' - 1"19' - 0 3/4"19' - 0 3/4"14' - 11"19' - 1 1/2"10' - 9" 14' - 11 1/4"19' - 1 1/2"19' - 9 1/4"
249' - 11"
ADA MOBILITY ROOM
ADA COMMUNICATION FEATURES ROOM
ADA SYMBOL LEGEND
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216OVERALL 3RD FLOORPLAN
A-103
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
3/32" = 1'-0"13RD FLOOR PLAN
0'6' 12'24'
SCALE: 3/32" = 1'-0"
5. SEE STRUCTURAL TO VERIFY LOCATIONS OF ALL SHEAR WALLS. SEE ELEVATIONS TO VERIFY EXTERIOR FINISHMATERIAL AND COLOR.
4. PROVIDE AN ACCESSIBLE ROUTE AND COMPLIANT WHEELCHAIR LOCATIONS IN EACH OF THE PUBLIC SPACESPROVIDED FOR GUEST USE.
3. BOTH VISUAL AND NOTIFICATION DEVICES SHALL BE PROVIDED IN PUBLIC AND COMMON AREAS. THE SYSTEMMUST BE DESIGNED TO BE ABLE TO BE INTEGRATED INTO EMPLOYEE WORK SPACES AND MUST COMPLY WITHNFPA 72 AND STATE, LOCAL AND FEDERAL REGULATIONS. DEVICES MUST BE LOCATED SO THE LIGHT IS VISIBLE INEACH REQUIRED SPACE.
2. ALL WALLS IN BATH SHALL BE MOISTURE RESISTANT GYPSUM BOARD. BATH CEILING SHALL BE EXTERIORGYPSUM BOARD.
1. REFER TO HOMEWOOD STANDARDS FOR FLOORING REQUIREMENTS IN EACH AREA.
GENERAL NOTES- FLOOR PLANS
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
Revision Schedule
Number Description Date
W/DW/DDN
UP
DN UP
A-2012
A-202
A-201
1
2
5
3
3.1
6.1
2.1
D
C.1
FG
ML.1E
1
A-301
C
C
B
B
1
KING STUDIOENLARGED
438
KING1-BEDROOM
402
KING1-BEDROOMENLARGED
401
DOUBLE
QUEEN
410
DOUBLE
QUEENENLARGED
412
KING STUDIO
414
EFFICIENCY
407
PANELS
409A
ELEVATORLOBBY417LINENS &
HOUSEKEEPING
409
EFFICIENCYADA-M-RI
403
CONNECTINGCORRIDOR
400
EFFICIENCY
408
EFFICIENCY
405
1,746 SF
GUESTCORRIDOR
415
ELEV 2
113
ELEV 1
111
LINEN CHUTE
140
BALCONY
401A
BALCONY
402A
BALCONY
419A
BALCONY
421A
BALCONY
423A
BALCONY
425A
BALCONY
435A
BALCONY
437A
STAIR 1
406
STAIR 2
432
IDF
409B
ELECTRICAL
415A
2
A-302
3
A-302
A-4161
A-412
1
DAC
409C
1
A-302
8.1
9
4
1.1
A
A
K N P Q
2
7
8
6
10
H
J
2
A-301
L
KING STUDIO
420
KING STUDIO
419
KING STUDIO
421
DOUBLEQUEEN
422
KING STUDIO
423
DOUBLE
QUEEN
424
KING STUDIO
426
KING STUDIO
425 EFFICIENCY
427
EFFICIENCY
428
EFFICIENCY
429
KING STUDIO
430
EFFICIENCY
431
EFFICIENCY
433
EFFICIENCY
434
DOUBLEQUEEN
436
DOUBLEQUEEN
435
KING STUDIO
437
KING STUDIO
418
KING STUDIO
416
KING STUDIO
404
P3.3
P3.1
P3.1
P3.2
P3.3
P4.2
P4.2
P3.2
P3.1
P3.1
XE1/2
XE1/2
XE1/2
XE1/2
XE1/2
XE1/2
XE1/2
XE1/2
XE1/2
XD2
XE1/2
XD2
XE1/2 XE1/2
P5.1
P3.2P3.2
P3.2 P3.2
P3.1 P3.1 P3.2 P3.1P3.2
XE1/2
XE1/2
XE1/2
XE1/2
XE1/2
XE1/2P3.1
XE1/2
P3.2P4.1P4.3P3.1P3.2P3.2P3.2P3.2P3.2P3.1P3.2P3.1 XE1/2XE1/2
XE1/2
XE1/2XW1XE1/2XE1/2
P3.1
P5.1P3.2
ADA MOBILITY ROOM
ADA COMMUNICATION FEATURES ROOM
ADA SYMBOL LEGEND
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216OVERALL 4TH FLOORPLAN
A-104
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
3/32" = 1'-0"14TH FLOOR PLAN
0'6' 12'24'
SCALE: 3/32" = 1'-0"
5. SEE STRUCTURAL TO VERIFY LOCATIONS OF ALL SHEAR WALLS. SEE ELEVATIONS TO VERIFY EXTERIOR FINISHMATERIAL AND COLOR.
4. PROVIDE AN ACCESSIBLE ROUTE AND COMPLIANT WHEELCHAIR LOCATIONS IN EACH OF THE PUBLIC SPACESPROVIDED FOR GUEST USE.
3. BOTH VISUAL AND NOTIFICATION DEVICES SHALL BE PROVIDED IN PUBLIC AND COMMON AREAS. THE SYSTEMMUST BE DESIGNED TO BE ABLE TO BE INTEGRATED INTO EMPLOYEE WORK SPACES AND MUST COMPLY WITHNFPA 72 AND STATE, LOCAL AND FEDERAL REGULATIONS. DEVICES MUST BE LOCATED SO THE LIGHT IS VISIBLE INEACH REQUIRED SPACE.
2. ALL WALLS IN BATH SHALL BE MOISTURE RESISTANT GYPSUM BOARD. BATH CEILING SHALL BE EXTERIORGYPSUM BOARD.
1. REFER TO HOMEWOOD STANDARDS FOR FLOORING REQUIREMENTS IN EACH AREA.
GENERAL NOTES- FLOOR PLANS
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
Revision Schedule
Number Description Date
W/DW/DDN
DN
A-2012
A-202
A-201
1
2
5
3
3.1
6.1
2.1
D
C.1
FG
ML.1
KING STUDIOENLARGED
538
KING1-BEDROOM
502
KING1-BEDROOMENLARGED
501
DOUBLE
QUEEN
510
KING STUDIO
504
DOUBLEQUEENADA-M-T
512
KING STUDIO
514
EFFICIENCY
507
ELEVATORLOBBY517LINENS &
HOUSEKEEPING
509
EFFICIENCYADA-M-T
503
CONNECTINGCORRIDOR
500
EFFICIENCY
508
EFFICIENCY
505
GUESTCORRIDOR
515
ELEV 2
113
ELEV 1
111
LINEN CHUTE
140
BALCONY
501ABALCONY
502A
BALCONY
519A
BALCONY
521A
BALCONY
523A
BALCONY
525A
BALCONY
535A
BALCONY
537A
STAIR 1
506
STAIR 2
532
E
1
A-301
IDF
509B
ELECTRICAL
515A
C
C
B
B
1
ROOF ACCESS
539
2
A-302
3
A-302
A-421
1DAC
509C
1
A-302
8.1
9
4
1.1
A
K N P Q
A-5013
A-5023
2
PANELS
509A
7
8
6
10
H
J
2
A-301
L
KING STUDIO
520
KING STUDIO
519
KING STUDIO
521
DOUBLEQUEEN
522
KING STUDIO
523
DOUBLE
QUEEN
524
KING STUDIO
526
KING STUDIO
525 EFFICIENCY
527
EFFICIENCY
528
EFFICIENCY
529
KING STUDIO
530
EFFICIENCY
531
EFFICIENCY
533
EFFICIENCY
534
DOUBLEQUEEN
536
DOUBLEQUEEN
535 KING STUDIO
537
KING STUDIO
518
KING STUDIO
516
P3.3
P3.1
P3.1
P3.2
P3.3
P4.2
P4.2
P3.2
P3.1
P3.1
XE1/2
XE1/2
XE1/2
XE1/2
XE1/2
XE1/2
XE1/2
XE1/2
XE1/2
XD2
XE1/2
XD2
XE1/2 XE1/2
P5.1
P3.2P3.2
P3.2 P3.2
P3.1 P3.1 P3.2 P3.1P3.2
XE1/2
XE1/2
XE1/2
XE1/2
XE1/2
XE1/2P3.1
XE1/2
P3.2P4.1P4.3P3.1P3.2P3.2P3.2P3.2P3.2P3.1P3.2P3.1 XE1/2XE1/2
XE1/2
XE1/2XW1XE1/2XE1/2
P3.1
P5.1P3.2
ADA MOBILITY ROOM
ADA COMMUNICATION FEATURES ROOM
ADA SYMBOL LEGEND
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216OVERALL 5TH FLOORPLAN
A-105
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
3/32" = 1'-0"15TH FLOOR PLAN
0'6' 12'24'
SCALE: 3/32" = 1'-0"
5. SEE STRUCTURAL TO VERIFY LOCATIONS OF ALL SHEAR WALLS. SEE ELEVATIONS TO VERIFY EXTERIOR FINISHMATERIAL AND COLOR.
4. PROVIDE AN ACCESSIBLE ROUTE AND COMPLIANT WHEELCHAIR LOCATIONS IN EACH OF THE PUBLIC SPACESPROVIDED FOR GUEST USE.
3. BOTH VISUAL AND NOTIFICATION DEVICES SHALL BE PROVIDED IN PUBLIC AND COMMON AREAS. THE SYSTEMMUST BE DESIGNED TO BE ABLE TO BE INTEGRATED INTO EMPLOYEE WORK SPACES AND MUST COMPLY WITHNFPA 72 AND STATE, LOCAL AND FEDERAL REGULATIONS. DEVICES MUST BE LOCATED SO THE LIGHT IS VISIBLE INEACH REQUIRED SPACE.
2. ALL WALLS IN BATH SHALL BE MOISTURE RESISTANT GYPSUM BOARD. BATH CEILING SHALL BE EXTERIORGYPSUM BOARD.
1. REFER TO HOMEWOOD STANDARDS FOR FLOORING REQUIREMENTS IN EACH AREA.
GENERAL NOTES- FLOOR PLANS
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
Revision Schedule
Number Description Date
A-2012
A-202
A-202
A-201
1
2
1
5
3
3.1
6.1
2.1
D
C.1
FG
ML.1E
1
A-301
C
C
B
B
1
2
A-302
3
A-302
11165' - 8 1/2"17' - 6 3/4"1
A-302
8.1
9
4
1.1
A
A
K N P Q
2
7
8
6
10
H
J1/4" / 1'-0"1/4" / 1'-0"1/4" / 1'-0"1/4" / 1'-0"1/4" / 1'-0"1/4" / 1'-0"1" / 1'-0"1" / 1'-0"1/4" / 1'-0"1/4" / 1'-0"
2
A-301
L
1
11
1
1
2
3
1 4 TYP.
5
6
7
7
84TYP.
9
9
9 9
9
98
8
8
10
11
12
13
14
15
16
17 TYP.
18
19 TYP.
19TYP.
20
20
20
2020
20
20
12' - 3 3/4"
23' - 6"23' - 6"1
A-507
21
21
21
21
21
22
22
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216ROOF PLAN
A-106
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
3/32" = 1'-0"1ROOF PLAN
0'6' 12'24'
SCALE: 3/32" = 1'-0"
KEYNOTES - ROOF PLANS
1 ROOF MOUNTED MECHANICAL EQUIPMENT - SEE MECHANICAL
2 ELEVATOR PENTHOUSE
3 LINEN CHUTE VENT
4 ROOF DRAIN AND OVERFLOW ROOF DRAIN - SEE PLUMBING.RUN RAIN LEADERS THROUGH CHASES OR WALLS FOR ENTIRERUN.
5 ROOF HATCH
6 SAFETY GATE FOR ROOF HATCH WITH FRONT GATE CLOSURE
7 POTENTIAL SOLAR PANEL AREA
8 CANOPY BELOW
9 BALCONY CANOPY BELOW
10 PORTE COCHERE BELOW
11 FAUX ROOF PARAPET
12 TRELLIS OVER POOL MEP ROOM
13 TRELLIS OVER OUTDOOR KITCHEN
14 ROOF OVER POOL ROOM BELOW, SLOPE TO DRAIN AT MIN. 1/4"= 1'0".
15 SMOKING SHELTER
16 ALTERNATING TREAD STAIR TO ROOF FROM 5TH FLOOR STAIR
17 PARAPETS- SEE DETAILS
18 TAPERED INSULATION CRICKET
19 WALKWAY/PROTECTION PAD IN CONTRASTING COLOR TOROOF
20 MEMBRANE ROOF, SLOPE STRUCTURE TO DRAIN TOWARDSROOF DRAINS.
21 EMERGENCY OVERFLOW SCUPPER
22 MINIMUM ROOF INSULATION DEPTH AT VALLEY: 4" (R-22.5)
4. COORDINATE ROOF DAVITS AND STANCHIONS PER OSHA ANDOWNER PREFERENCE.
3. COORDINATE SOLAR DESIGN WITH SOLAR PANEL DESIGNER.
2. KEEP ROOF MOUNTED EQUIPMENT AWAY FROM PARAPETSWHEN POSSIBLE TO REDUCE SIGHT LINES.
1. ALL ROOFTOP EQUIPMENT, PLUMBING, VENTS, CONDENSINGUNITS, EXHAUST FANS, BOISER FLUES, ETC. ARE TO BECONCEALED FROM VIEW BEHIND PARAPET WALLS.
GENERAL NOTES - ROOF
WEIGHTED MAIN ROOF INSULATION CALCULATIONS
R-VAL OF FRACTIONALPORTION OF ROOF AREA PERCENTAGE PORTION R-VALNORTH TRIANGULAR PORTION: 939.56 SF 5.28% OF ROOF * 53.076 = R-2.8EAST RECTANGULAR PORTION: 2,059.25 SF 1.57% OF ROOF * 43.44 = R-5.03WEST RECTANGULAR PORTION: 2,961.49 SF 16.64% OF ROOF * 43.44 = R-7.23NORTH RECTANGULAR PORTION: 4,910.36 SF 27.6% OF ROOF * 43.44 = R-11.99SOUTH RECTANGULAR PORTION: 6,089.02 SF 34.22% OF ROOF * 43.44 = R-14.87EAST TRIANGULAR PORTION: 833.16 SF 4.67% OF ROOF * 53.076 = R-2.49
TOTAL MAIN ROOF AREA 17,792.83 SF TOTAL WEIGHTED ROOF R-VALUE R-44.4
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
Revision Schedule
Number Description Date
DDDD
WWWW
DN
UP
DN
UP
A-2012
A-202
A-202
A-201
1
2
1
5
3
3.1
6.1
2.1
D
C.1
FG
ML.1E
1
A-301
C
C
B
B
1
2
A-302
3
A-302
11
1
A-302
8.1
9
4
1.1
A
A
K N P Q
2
23' - 6"23' - 6"44' - 0"1' - 11"11' - 2 3/4"16' - 7"3
A-505
7
8
6
10
H
H J
12' - 0"1/4" / 1'-0"1/4" / 1'-0"1/4" / 1'-0"1/4" / 1'-0"
2
A-301
1
A-505
L1/4" / 1'-0"1/4" / 1'-0"5' - 8"13' - 1 1/2"1/4" / 1'-0"
15' - 0 3/4" RC-5
15' - 1" RC-6
11' - 7 3/4" RC-3
15' - 9 1/2"
13' - 7 1/4"1/2" / 1'-0"1/4" / 1'-0"1/4" / 1'-0"8
4TYP.
8
8
12
13
14
15
11/32" / 1'-0"15/64" / 1'-0"1/4" / 1'-0"1/4" / 1'-0"1/4" / 1'-0"1/4" / 1'-0"737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216LOWER ROOF PLAN
A-107
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
0'6' 12'24'
SCALE: 3/32" = 1'-0"
3/32" = 1'-0"1LOWER ROOF PLAN
KEYNOTES - ROOF PLANS
1 ROOF MOUNTED MECHANICAL EQUIPMENT - SEE MECHANICAL
2 ELEVATOR PENTHOUSE
3 LINEN CHUTE VENT
4 ROOF DRAIN AND OVERFLOW ROOF DRAIN - SEE PLUMBING.RUN RAIN LEADERS THROUGH CHASES OR WALLS FOR ENTIRERUN.
5 ROOF HATCH
6 SAFETY GATE FOR ROOF HATCH WITH FRONT GATE CLOSURE
7 POTENTIAL SOLAR PANEL AREA
8 CANOPY BELOW
9 BALCONY CANOPY BELOW
10 PORTE COCHERE BELOW
11 FAUX ROOF PARAPET
12 TRELLIS OVER POOL MEP ROOM
13 TRELLIS OVER OUTDOOR KITCHEN
14 ROOF OVER POOL ROOM BELOW, SLOPE TO DRAIN AT MIN. 1/4"= 1'0".
15 SMOKING SHELTER
16 ALTERNATING TREAD STAIR TO ROOF FROM 5TH FLOOR STAIR
17 PARAPETS- SEE DETAILS
18 TAPERED INSULATION CRICKET
19 WALKWAY/PROTECTION PAD IN CONTRASTING COLOR TOROOF
20 MEMBRANE ROOF, SLOPE STRUCTURE TO DRAIN TOWARDSROOF DRAINS.
21 EMERGENCY OVERFLOW SCUPPER
22 MINIMUM ROOF INSULATION DEPTH AT VALLEY: 4" (R-22.5)
4. COORDINATE ROOF DAVITS AND STANCHIONS PER OSHA ANDOWNER PREFERENCE.
3. COORDINATE SOLAR DESIGN WITH SOLAR PANEL DESIGNER.
2. KEEP ROOF MOUNTED EQUIPMENT AWAY FROM PARAPETSWHEN POSSIBLE TO REDUCE SIGHT LINES.
1. ALL ROOFTOP EQUIPMENT, PLUMBING, VENTS, CONDENSINGUNITS, EXHAUST FANS, BOISER FLUES, ETC. ARE TO BECONCEALED FROM VIEW BEHIND PARAPET WALLS.
GENERAL NOTES - ROOF
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
Revision Schedule
Number Description Date
5
3
3.1
6.1
2.1
D
C.1E
MEN'SRESTROOM
116
WOMEN'SRESTROOM
115
MEETINGSTORAGE
119
MEETINGROOM
120
GUESTSTORAGE
118
FITNESS
114
ELEV 2
113
ELEV 1
111
ELEVATORLOBBY117LAUNDRYLOUNGE
112
EMPLOYEEROOM
110
WATERHEATER & FIRE
108
EMP RR ADA
110AEMP RR
110B
POOL &SPLASH PAD
101
POOL
RESTROOM
102
ELECTRICAL
104
STAIR 1
106
PUBLICCORRIDOR
100
BOH LAUNDRY
105
LINENSTORAGE
109
HOUSEKEEPINGOFFICE
109A
LINEN CHUTE
140
LINENDISCHARGE &SORTING
107
POOL MEP
103
CL-A10' - 0"
CL-B11' - 6"
CL-B29' - 0"
CL-A10' - 0"
CL-B29' - 0"
CL-B29' - 0"
CL-B10' - 0"CL-C10' - 0"CL-A10' - 0"
CL-B114' - 8 3/4"
CL-A11' - 0"
CL-B29' - 0"
CL-B8' - 0"
CL-B212' - 0"
C
C
B
B
1
CL-A10' - 0"
CL-B29' - 0"
CL-B114' - 8 3/4"
3
A-302
CL-B114' - 8 3/4"
CL-A10' - 0"
8.1
9
4
1.1
A
A-131
1
2
BOH DRYERS
105A
43 SF
VESTIBULE
100A/1 A-112/1 A-112
7
8
6
10
CL-B8' - 0"
CL-B211' - 4"
CL-B12' - 4"
CL-B19' - 0"2' - 6"0' - 7 1/2"CL-C10' - 0"
CL-A10' - 0"
CL-B10' - 0"
CEILING LEGEND
CL-A (2' X 2' ACT TILES)
CL-A WHITE, FINE TEXTURE, CONCEALED SUSPENSION SYSTEM
CL-A1 GREY, FINE TEXTURE, CONCEALED SUSPENSION SYSTEM
CL-A2 WHITE, WASHABLE, CLEAN ROOM SUSPENSION SYSTEM
CL-B (1 HR GWB)
CL-B SUSPENDED SYSTEM, 1 LAYER TYPE X GWB, PT-01 FINISH
CL-B1 DIRECT-ATTACHED, 1 LAYER TYPE X GWB, PT-01 FINISH
CL-B2 SUSPENDED SYSTEM, 1 LAYER EXTERIOR-RATED GWB, PT-01 FINISH
CL-B3 DIRECT-ATTACHED, 1 LAYER EXTERIOR-RATED GWB, PT-01 FINISH
CL-C (2 HR GWB)
CL-C SUSPENDED SYSTEM, SEE DETAIL, PT-01FINISH
CL-D (FIBER CEMENT, EXTERIOR/SOFFIT)
CL-D SUSPENDED SYSTEM, 1 LAYER 1/2" FIBER CEMENT, PT-01FINISH
CL-D1 DIRECT-ATTACHED, 1 LAYER 1/2" FIBER CEMENT, PT-01FINISH
CL-E (FIBER CEMENT, EXTERIOR/SOFFIT)
CL-E SUSPENDED SYSTEM, 1 LAYER TYPE X GWB, 1 LAYER PLYWOOD WITH PLASTIC LAMINATE FINISH
NOTE: REFER TO FF&E PACKAGE AND SPECIFICATION BOOK FOR FURNITURE AND FINISH SPECIFICATIONS
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216OVERALL 1ST FLOORREFLECTED CEILINGPLAN - WEST WING
A-111
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
1/8" = 1'-0" Reference: 3 / A-002
11ST FLOOR REFLETED CEILING PLAN - WEST WING
0'4' 8'16'
SCALE: 1/8" = 1'-0"
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
Revision Schedule
Number Description Date
SDSDSD
SDSD SD
5
FG M
L.1
E
2
A-302
11
9
4
K N P Q
MEETINGROOM
120
VESTIBULE
122
COURTYARDSTORAGE
141
GUESTCORRIDOR
139
LOBBY
121
CL-D9' - 0"
CL-A11' - 0"
CL-B11' - 2"
CL-B7' - 1"
CL-A10' - 0"
CL-B314' - 8 3/4"
CL-A12' - 2"
CL-A12' - 2"
CL-A211' - 0"
FOOD PREP
123
SALES OFFICE
126
GM OFFICE
125
OPEN OFFICE
124
ELECTRICAL
128
CL-A9' - 0"
CL-B114' - 6"KING STUDIOADA-M-T
138
KING STUDIO
137
DOUBLE
QUEEN
135
DOUBLEQUEEN
136
EFFICIENCY
133
EFFICIENCY
134
EFFICIENCY
131
EFFICIENCY
129
KING STUDIO
130
STAIR 2
132
OWNER'SOFFICE
127
PUBLICCORRIDOR
121A
VESTIBULE
139A
ELECTRICAL
139B CL-B29' - 0"/1 A-111/1 A-111
3
A-505
7
8
6
10
HJ
CL-D10' - 5"CL-D10' - 5"
CL-D13' - 10"CL-D13' - 10"
CL-B10' - 0"
2
A-301
1
A-505
CL-B10' - 0"
CL-D114' - 3"1/2" / 1'-0"CL-D19' - 0"
CL-B12' - 2"
CL-B12' - 2"
CL-B12' - 2"
14' - 11 1/2"
13' - 11 1/4"
CL-E10' - 10"
CL-B11' - 2"
Trellis 10'-4"
A-4082
11
A-510
Typ
11
A-510
Typ
14
A-510
13
A-510
12
A-510
15
A-510
TypCL-A12' - 2"
CL-A112' - 2"
CL-B10' - 0"
L
11' - 7 3/4" RC-3
11' - 7 3/4" RC-4
17' - 3 3/4" RB-117' - 3 3/4" RB-1
RC-510' - 0"
CEILING LEGEND
CL-A (2' X 2' ACT TILES)
CL-A WHITE, FINE TEXTURE, CONCEALED SUSPENSION SYSTEM
CL-A1 GREY, FINE TEXTURE, CONCEALED SUSPENSION SYSTEM
CL-A2 WHITE, WASHABLE, CLEAN ROOM SUSPENSION SYSTEM
CL-B (1 HR GWB)
CL-B SUSPENDED SYSTEM, 1 LAYER TYPE X GWB, PT-01 FINISH
CL-B1 DIRECT-ATTACHED, 1 LAYER TYPE X GWB, PT-01 FINISH
CL-B2 SUSPENDED SYSTEM, 1 LAYER EXTERIOR-RATED GWB, PT-01 FINISH
CL-B3 DIRECT-ATTACHED, 1 LAYER EXTERIOR-RATED GWB, PT-01 FINISH
CL-C (2 HR GWB)
CL-C SUSPENDED SYSTEM, SEE DETAIL, PT-01FINISH
CL-D (FIBER CEMENT, EXTERIOR/SOFFIT)
CL-D SUSPENDED SYSTEM, 1 LAYER 1/2" FIBER CEMENT, PT-01FINISH
CL-D1 DIRECT-ATTACHED, 1 LAYER 1/2" FIBER CEMENT, PT-01FINISH
CL-E (FIBER CEMENT, EXTERIOR/SOFFIT)
CL-E SUSPENDED SYSTEM, 1 LAYER TYPE X GWB, 1 LAYER PLYWOOD WITH PLASTIC LAMINATE FINISH
NOTE: REFER TO FF&E PACKAGE AND SPECIFICATION BOOK FOR FURNITURE AND FINISH SPECIFICATIONS
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216OVERALL 1ST FLOORREFLECTED CEILINGPLAN - EAST WING
A-112
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
1/8" = 1'-0"11ST FLOOR REFLECTED CEILING PLAN - EAST WING
0'4' 8'16'
SCALE: 1/8" = 1'-0"
0'4" 8"1' 4"
SCALE: 1 1/2" = 1'-0"
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
Revision Schedule
Number Description Date
SDSD
SD
SD
SD
SD
SD
SD
SD
SDSDSDSDSDSDSDSDSDSD5
3
3.1
6.1
2.1
D
C.1E
1
A-301
C
C
B
B
1
3
A-302
1
A-302
8.1
9
4
1.1
A
2
KING STUDIO
319
KING STUDIO
320
KING STUDIO
318
KING STUDIO
316
LINENS &HOUSEKEEPING
309
KING STUDIO
314
DOUBLEQUEENENLARGED
312
DOUBLE
QUEEN
310
EFFICIENCY
308
STAIR 1
306
KING STUDIO
304
KING1-BEDROOM
302
EFFICIENCY
ENLARGED
303
KING1-BEDROOMADA-M-T
301
EFFICIENCY
305
EFFICIENCY
307
GUESTCORRIDOR
315ELEVATORLOBBY317ELEV 1
111
ELEV 2
113
CONNECTINGCORRIDOR
300
LINEN CHUTE
140
IDF
309B
7
8
6
10
CL-A8' - 0"
CL-B8' - 6"
CL-B19' - 8 3/4"
CEILING LEGEND
CL-A (2' X 2' ACT TILES)
CL-A WHITE, FINE TEXTURE, CONCEALED SUSPENSION SYSTEM
CL-A1 GREY, FINE TEXTURE, CONCEALED SUSPENSION SYSTEM
CL-A2 WHITE, WASHABLE, CLEAN ROOM SUSPENSION SYSTEM
CL-B (1 HR GWB)
CL-B SUSPENDED SYSTEM, 1 LAYER TYPE X GWB, PT-01 FINISH
CL-B1 DIRECT-ATTACHED, 1 LAYER TYPE X GWB, PT-01 FINISH
CL-B2 SUSPENDED SYSTEM, 1 LAYER EXTERIOR-RATED GWB, PT-01 FINISH
CL-B3 DIRECT-ATTACHED, 1 LAYER EXTERIOR-RATED GWB, PT-01 FINISH
CL-C (2 HR GWB)
CL-C SUSPENDED SYSTEM, SEE DETAIL, PT-01FINISH
CL-D (FIBER CEMENT, EXTERIOR/SOFFIT)
CL-D SUSPENDED SYSTEM, 1 LAYER 1/2" FIBER CEMENT, PT-01FINISH
CL-D1 DIRECT-ATTACHED, 1 LAYER 1/2" FIBER CEMENT, PT-01FINISH
CL-E (FIBER CEMENT, EXTERIOR/SOFFIT)
CL-E SUSPENDED SYSTEM, 1 LAYER TYPE X GWB, 1 LAYER PLYWOOD WITH PLASTIC LAMINATE FINISH
NOTE: REFER TO FF&E PACKAGE AND SPECIFICATION BOOK FOR FURNITURE AND FINISH SPECIFICATIONS
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216OVERALL TYP. 2ND TO5TH FLOOR REFLECTEDCEILING PLAN - WESTWING
A-113
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
0'6' 12'24'
SCALE: 3/32" = 1'-0"
1/8" = 1'-0" Reference: 3 / A-002
1TYPICAL 2ND-RTH FLOOR RCP - WEST WING
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
Revision Schedule
Number Description Date
SDSD SDSDSDSD
SDSD
SDSD SDSDSD5
FG
ML.1
E
KING STUDIOADA-M-RI
338
KING STUDIO
337
DOUBLEQUEEN
335
DOUBLEQUEEN
336
EFFICIENCY
333
EFFICIENCY
334
STAIR 2
332
EFFICIENCY
331
EFFICIENCY
329
EFFICIENCY
327
KING STUDIO
325
KING STUDIO
323
KING STUDIO
321
KING STUDIO
319
KING STUDIO
330
EFFICIENCY
328
KING STUDIO
326
DOUBLE
QUEEN
324
DOUBLEQUEEN
322
KING STUDIO
320
KING STUDIO
318
GUESTCORRIDOR
315ELEVATORLOBBY317 ELECTRICAL
315A
2
A-302
9
4
K N P Q
7
8
6
10
HJ
2
A-301
L
CEILING LEGEND
CL-A (2' X 2' ACT TILES)
CL-A WHITE, FINE TEXTURE, CONCEALED SUSPENSION SYSTEM
CL-A1 GREY, FINE TEXTURE, CONCEALED SUSPENSION SYSTEM
CL-A2 WHITE, WASHABLE, CLEAN ROOM SUSPENSION SYSTEM
CL-B (1 HR GWB)
CL-B SUSPENDED SYSTEM, 1 LAYER TYPE X GWB, PT-01 FINISH
CL-B1 DIRECT-ATTACHED, 1 LAYER TYPE X GWB, PT-01 FINISH
CL-B2 SUSPENDED SYSTEM, 1 LAYER EXTERIOR-RATED GWB, PT-01 FINISH
CL-B3 DIRECT-ATTACHED, 1 LAYER EXTERIOR-RATED GWB, PT-01 FINISH
CL-C (2 HR GWB)
CL-C SUSPENDED SYSTEM, SEE DETAIL, PT-01FINISH
CL-D (FIBER CEMENT, EXTERIOR/SOFFIT)
CL-D SUSPENDED SYSTEM, 1 LAYER 1/2" FIBER CEMENT, PT-01FINISH
CL-D1 DIRECT-ATTACHED, 1 LAYER 1/2" FIBER CEMENT, PT-01FINISH
CL-E (FIBER CEMENT, EXTERIOR/SOFFIT)
CL-E SUSPENDED SYSTEM, 1 LAYER TYPE X GWB, 1 LAYER PLYWOOD WITH PLASTIC LAMINATE FINISH
NOTE: REFER TO FF&E PACKAGE AND SPECIFICATION BOOK FOR FURNITURE AND FINISH SPECIFICATIONS
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216OVERALL TYP. 2ND TO5TH FLOOR REFLECTEDCEILING PLAN - EASTWING
A-114
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
0'4' 8'16'
SCALE: 1/8" = 1'-0"
1/8" = 1'-0" Reference: 3 / A-002
1TYPICAL 2ND-5TH FLOOR RCP - EAST WING
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
Revision Schedule
Number Description Date
DDDD
WWWW
UP
5
3
3.1
6.1
2.1
D
C.1E
1
A-301
C
C
B
B
1
3
A-302
A-4359
171 SF
MEN'SRESTROOM
116
172 SF
WOMEN'SRESTROOM
115
81 SF
MEETINGSTORAGE
119
406 SF
MEETINGROOM
120176 SFGUESTSTORAGE118801 SF
FITNESS
114
257 SF
LAUNDRYLOUNGE
112
432 SF
EMPLOYEEROOM
110
361 SF
WATERHEATER & FIRE
108
50 SF
EMP RR ADA
110A30 SF
EMP RR
110B
2,152 SF
POOL &SPLASH PAD
101
80 SF
POOLRESTROOM
102
548 SF
ELECTRICAL
104
191 SF
STAIR 1
106
711 SF
PUBLICCORRIDOR
100
750 SF
BOH LAUNDRY
105
85 SF
LINENSTORAGE
109
56 SF
HOUSEKEEPINGOFFICE
109A
131 SF
LINEN
DISCHARGE &SORTING
107
204 SF
POOL MEP
103
176 SFELEVATORLOBBY11764 SF
ELEV 2
113
68 SF
ELEV 1
111
13 SF
LINEN CHUTE
140
A-4429
/1 A-122/1 A-122
W-BW-BW-BW-B
W-B
W-B
W-B
W-B
W-B
W-A
CW-F
CW-F
CW-F
CW-GCW-GCW-GCW-GCW-G
43 SF
VESTIBULE
100A
A-4441
CW-H
CW-L
W-EW-DW-E
CW-K
D-116
D-115
D-119
D-114
D-112
D-108
D-110
D-110AD-110B
D-109
D-105
D-107
D-104
D-105A
D-106
D-101A
D-103
D-101
D-108A
D-120
CW-K
CW-K
8.1
9
4
1.1
A
A
A-5011
2
CW-F
CW-F
CW-F
D-102
D-100A
P1.1
P3.1
P3.1
P1.1
P1.1
<varies>
P3.3
P3.1
P1.1
P6
P3.1
P3.1
P3.1
P4.2
P4.1
P4.2
P3.1P3.3
P2.2P1.1
P2.1
P7
P1.2P5.1
P5.3
P2.3
P3.3P3.3
P8P8
P8P8
P3.1
P3.3
P2.2
P1.1
P1.2
P1.2
P5.4
XS3
XS3XS3
XS3
XS1
XE1/2
XS2
XE1/2
XE3
XE3
<varies>
XS1
XS1XE1/2
7
8
6
10
A-452
1
P2.2
P1.2
XS1
P5.2
P5.1
P5.4
D-117XE1/2
XE8
XE4
P6
P6
P5.5
CS-01
P6
D-104A
P2.1
P3.1
D-100
D-106A
30' - 6 3/4"5' - 10 1/4"19' - 6 1/2"19' - 1"6' - 0"19' - 7 1/4"4' - 7 1/2" 6' - 1 1/4" 8' - 8 3/4"15' - 2 3/4" 3' - 11 1/4" 15' - 0 1/2"9' - 3" 5' - 10"13' - 5" 2' - 2"23' - 6 3/4"4' - 2 1/2"30' - 6 3/4"5' - 10 1/4"28' - 8 1/2"
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 992161ST FLOORCONTRUCTION PLAN -WEST WING
A-121
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
0'4' 8'16'
SCALE: 1/8" = 1'-0"
1/8" = 1'-0" Reference: 1 / A-101
11ST FLOOR CONSTRUCTION PLAN - WEST WING
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
Revision Schedule
Number Description Date
UP
5
6.1
C.1
F
F
G
G
M
M
L.1
L.1
E
E
1
A-301
C
C
2
A-302
11
171 SF
MEN'SRESTROOM
116
172 SF
WOMEN'SRESTROOM
115
81 SF
MEETING
STORAGE
119
406 SF
MEETINGROOM
120
176 SF
GUESTSTORAGE
118
150 SF
VESTIBULE
122
46 SF
COURTYARDSTORAGE
141
428 SF
GUESTCORRIDOR
1392,670 SF
LOBBY
121
131 SF
LINEN
DISCHARGE &SORTING
107
104 SF
OWNER'SOFFICE
127
95 SF
GM OFFICE
125106 SF
SALES OFFICE
126
233 SF
OPEN OFFICE
124
135 SF
ELECTRICAL
128
594 SF
FOOD PREP
123
538 SF
DOUBLEQUEEN
135
353 SF
EFFICIENCY
133
176 SFELEVATORLOBBY117352 SF
EFFICIENCY
129
353 SF
EFFICIENCY
131
419 SF
KING STUDIO
130
64 SF
ELEV 2
113
68 SF
ELEV 1
111
13 SF
LINEN CHUTE
140
226 SF
STAIR 2
132
10 SF
ELECTRICAL
139B
353 SF
EFFICIENCY
134
541 SF
DOUBLEQUEEN
136
483 SF
KING STUDIO
ADA-M-T
138
54 SF
PATIO
135A
54 SF
PATIO
137A
A-4345/1 A-121/1 A-121
W-BW-BW-B
W-B
CW-D
CW-D
CW-ECW-E
CW-C
CW-H
CW-K
D-119
D-120
CW-N
D-124 D-128
D-125D-126
D-127
D-139 D-139A
D-139B
D-X32
D-141
D-122A
8.1
99
4
K
K
N
N
P
P
Q
Q
A-502
1
A-5041
A-4311
P3.3
P1.2
P3.3
P3.1
P3.3
P3.3
P4.2
P4.2
P1.2
P1.2
P1.2
P3.3
P2.2
P2.2
P2.3
P1.1
P3.2P4.1
P4.3
P3.1P3.1P5.1
P3.3
P1.2
XS2
XE3 XE3XE3XE3
XS1
XE1/2
XE1/2
XS1
XS1
XE1/2
XE3 XE3
XE1/2
XS1
XE3
XS4
XS1
XS1XE1/2
XE1/2
XE1/2
P1.2
426 SF
KING STUDIO
137
XE1/2
P5.1
7
8
6
10
HJ
A-450
1
2
A-301
1
A-505
L
CW-M
XS4
P3.1
CW-D
D-132
D-117D-121
D-122
D-123
D-115
D-116
W-B
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 992161ST FLOORCONTRUCTION PLAN -EAST WING
A-122
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
0'4' 8'16'
SCALE: 1/8" = 1'-0"
1/8" = 1'-0" Reference: 1 / A-101
11ST FLOOR ENLARGED CONSTRUCTION PLAN - EAST WING
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
REVISION SCHEDULE
# DESCRIPTION DATE
2 ADDENDUM 2 6/21/2024
2
W/DW/DA-202
A-2022
1
5
3
3.1
6.1
2.1
D
C.1
C.1
E
E
1
A-301
C
C
B
B
1
3
A-302
/1 A-124/1 A-124
W-H
W-C
W-G
W-C
619 SF
KING1-BEDROOM
X02
716 SF
KING1-BEDROOM
ENLARGED
X01
402 SF
EFFICIENCYENLARGED
X03420 SF
KING STUDIO
X04
58 SF
BALCONY
X01A
58 SF
BALCONY
X02A
420 SF
KING STUDIO
X16
420 SF
KING STUDIO
X18420 SF
KING STUDIO
X20422 SF
KING STUDIO
X14
568 SF
DOUBLE
QUEENENLARGED
X12
541 SF
DOUBLE
QUEEN
X10
355 SF
EFFICIENCY
X08
356 SF
EFFICIENCY
X05
497 SF
LINENS &
HOUSEKEEPING
X09
255 SF
ENGINEERINGOFFICE &
STORAGE
207
98 SF
PBX/MDF
207A
157 SF
ELEVATOR
LOBBY
X17
D-X17
D-207
191 SF
STAIR 1
X06
D-207B
D-207A
1,746 SF
GUEST
CORRIDOR
X15
8.1
9
4
1.1
A
A
A-5012
2
EFFICIENCYX07353 SF
5 SF
IDF
X09B
6 SF
DAC
X09C
<varies>
P3.2
P5.4
P5.1
P4.2
P5.5
P3.2
P1.2P1.2
P3.2
P3.1
<varies>
P3.2P3.4
P1.2
P1.2
P4.2
P4.2P4.1
XE1/2
XE1/2
XE1/2
XE1/2
XE1/2
XE1/2
XE1/2
XE1/2
XE1/2
XE3
<varies>
XE1/2
XE1/2
<varies>
A-419A1
7
8
6
10
98 SF
CONNECTINGCORRIDOR
X00
W-C
A-453
1
A-4532
6' - 0"19' - 7 1/4"19' - 5 1/2"19' - 2"15' - 0 1/2"9' - 3"19' - 2 3/4"25' - 8 3/4"4' - 2 1/2"30' - 6 3/4"5' - 10 1/4"19' - 6 1/2"19' - 1"
30' - 6 3/4"5' - 10 1/4"28' - 8 1/2"15' - 0 1/2"15' - 0 3/4"15' - 7"27' - 9 1/4"737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216TYPICAL 2ND-5THFLOOR CONTRUCTIONPLAN - WEST WING
A-123
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
0'4' 8'16'
SCALE: 1/8" = 1'-0"
1/8" = 1'-0" Reference: 1 / A-102
1TYPICAL 2ND-5TH FLOOR CONSTRUCTION PLAN - WEST WING
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
Revision Schedule
Number Description Date
5
C.1
FG M
L.1
E
1
A-301
2
A-302
11/1 A-123/1 A-123
W-C
420 SF
KING STUDIO
X19
420 SF
KING STUDIO
X21
420 SF
KING STUDIO
X23
420 SF
KING STUDIO
X25
354 SF
EFFICIENCY
X27
353 SF
EFFICIENCY
X29
354 SF
EFFICIENCY
X31
353 SF
EFFICIENCY
X33
540 SF
DOUBLE
QUEEN
X35
426 SF
KING STUDIO
X37
420 SF
KING STUDIO
X18
420 SF
KING STUDIO
X20
536 SF
DOUBLE
QUEEN
X22
536 SF
DOUBLE
QUEEN
X24420 SF
KING STUDIO
X26
354 SF
EFFICIENCY
X28 420 SF
KING STUDIO
X30
543 SF
DOUBLEQUEEN
X36 483 SF
KING STUDIOADA-M-T
X38
157 SF
ELEVATORLOBBY
X17
D-X17
353 SF
EFFICIENCY
X34
1,746 SF
GUESTCORRIDOR
X15
9
4
K N P Q
A-502
2
A-504
2
226 SF
STAIR 2
X32
68 SF
ELEV 1
111
64 SF
ELEV 2
113
58 SF
BALCONY
X19A
58 SF
BALCONY
X21A
58 SF
BALCONY
X23A
58 SF
BALCONY
X25A
57 SF
BALCONY
X37A
57 SF
BALCONY
X35A
P5.4
P5.1
P4.2
P3.2P3.1P3.2
P3.1
P4.1
P4.3
P1.2
A-411A2A-411A1
<varies>
XE1/2XE1/2
XE1/2
XE1/2 XE1/2
XE1/2
XE3
XE1/2
XE1/2
XE1/2
XE1/2
<varies>XE1/2
XE1/2XE1/2
3
A-505
7
8
6
10
HJ
2
A-301
1
A-505
L
19' - 1"19' - 0 3/4"28' - 0"6' - 0"24' - 2 3/4"6' - 1 1/4"23' - 11 3/4"3' - 11 1/4"19' - 0 3/4"14' - 11"19' - 1 1/2"10' - 9"14' - 11 1/4"19' - 1 1/2"19' - 9 1/4"
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216TYPICAL 2ND-5THFLOOR CONTRUCTIONPLAN - EAST WING
A-124
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
0'4' 8'16'
SCALE: 1/8" = 1'-0"
1/8" = 1'-0" Reference: 1 / A-102
1TYPICAL 2ND-5TH FLOOR CONSTRUCTION PLAN - EAST WING
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
Revision Schedule
Number Description Date
DDDD
WWWW
UP
5
3
3.1
6.1
2.1
D
C.1E
CB
1
8.1
9
4
1.1
A
171 SF
MEN'SRESTROOM
116
172 SF
WOMEN'SRESTROOM
115
81 SF
MEETING
STORAGE
119
406 SF
MEETING
ROOM
120176 SFGUESTSTORAGE118801 SF
FITNESS
114
257 SF
LAUNDRYLOUNGE
112
432 SF
EMPLOYEEROOM
110
361 SF
WATERHEATER & FIRE
108
50 SF
EMP RR ADA
110A30 SF
EMP RR
110B
2,152 SF
POOL &SPLASH PAD
101
80 SF
POOLRESTROOM
102
337 SF
ELECTRICAL
104
191 SF
STAIR 1
106
711 SF
PUBLICCORRIDOR
100
750 SF
BOH LAUNDRY
105
85 SF
LINENSTORAGE
109
56 SF
HOUSEKEEPINGOFFICE
109A
131 SF
LINENDISCHARGE &SORTING
107
204 SF
POOL MEP
103
176 SFELEVATORLOBBY11764 SF
ELEV 2
113
68 SF
ELEV 1
111
13 SF
LINEN CHUTE
140
/1 A-132/1 A-132
43 SF
VESTIBULE
100A
2
7
8
6
10
CPT-10CT-10
CPT-12
CT-10
CT-10
CT-10
RES-10
RES-11
CT-10
VCT-01
CT-10
CT-10
CS-01
CS-01
CT-10
CT-10CS-01
CT-10
CPT-14
VCT-01
VCT-01
VCT-01
VCT-01
BOH DRYERS
105ACS-01CS-01
11' - 0"6' - 6"
RES-12
RES-13
CT-19
ACT ACOUSTIC CEILING TILEASALUMINUM STOREFRONTCGCORNER GUARDCONC CONCRETE, UNFINISHEDCPCARPETCPTCARPET TILECSCONCRETE, FINISHEDGWBGYPSUM WALL BOARDFCFIBER CEMENTFRPFIBERGLASS-REINFORCEDPLASTICMR GWB MOISTURE-RESISTANT GWBPFPRE-FINISHED DOORPLPLASTIC LAMINATEPTPAINT/POWDER COATQTQUARRY TILERBRUBBER BASERESRESILIENT TILE FLOORSCSTAMPED CONCRETESFSPECIALTY FINISH (KNOCK DOWN)SS ENGINEERED SOLID SURFACESTSTONESTLSTAINLESS STEELSTRUC STRUCTURE ABOVEVCTVINYL COMPOSITE TILEWCVINYL WALL COVERINGWDWOOD-LOOK ALUMINUM SLATS AND BATTENSWPSCREEN WALL
NOTE: REFER TO FF&E PACKAGE AND SPECIFICATION BOOK FOR FURNITURE AND FINISH SPECIFICATIONS
FINISH LEGEND
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 992161ST FLOOR FINISH PLAN- WEST WING
A-131
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
1/8" = 1'-0"11ST FLOOR FINISH PLAN - WEST WING
0'4' 8'16'
SCALE: 1/8" = 1'-0"
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
REVISION SCHEDULE
# DESCRIPTION DATE
2 ADDENDUM 2 6/21/2024
22
22
22
22
2
2
2
2
2
2
2
2
UP
5
C.1
FG
ML.1E
11
9
4
K N P Q
81 SF
MEETINGSTORAGE
119
406 SF
MEETINGROOM
120
176 SF
GUEST
STORAGE
118
150 SF
VESTIBULE
122
46 SF
COURTYARDSTORAGE
141
428 SF
GUESTCORRIDOR
1392,670 SF
LOBBY
121
131 SF
LINEN
DISCHARGE &SORTING
107
104 SF
OWNER'SOFFICE
127
95 SF
GM OFFICE
125106 SF
SALES OFFICE
126
233 SF
OPEN OFFICE
124
135 SF
ELECTRICAL
128
594 SF
FOOD PREP
123
538 SF
DOUBLE
QUEEN
135
353 SF
EFFICIENCY
133
176 SFELEVATORLOBBY117352 SF
EFFICIENCY
129
353 SF
EFFICIENCY
131
419 SF
KING STUDIO
130
64 SF
ELEV 2
113
68 SF
ELEV 1
111
13 SF
LINEN CHUTE
140
226 SF
STAIR 2
132
10 SF
ELECTRICAL
139B
353 SF
EFFICIENCY
134
541 SF
DOUBLEQUEEN
136
483 SF
KING STUDIO
ADA-M-T
138
54 SF
PATIO
135A
54 SF
PATIO
137A
/1 A-131/1 A-131
7
8
6
10
H
J
CPT-12
CPT-11
CPT-11
CT-10
L
CPT-14
CT-10
CPT-10 CT-10
QT-01
CS-01
CS-01
RES-12
CPT-14CT-10
ICE/WATER
118A
VCT-01
CPT-12
ACT ACOUSTIC CEILING TILEASALUMINUM STOREFRONTCGCORNER GUARDCONC CONCRETE, UNFINISHEDCPCARPETCPTCARPET TILECSCONCRETE, FINISHEDGWBGYPSUM WALL BOARDFCFIBER CEMENTFRPFIBERGLASS-REINFORCEDPLASTICMR GWB MOISTURE-RESISTANT GWBPFPRE-FINISHED DOORPLPLASTIC LAMINATEPTPAINT/POWDER COATQTQUARRY TILERBRUBBER BASERESRESILIENT TILE FLOORSCSTAMPED CONCRETESFSPECIALTY FINISH (KNOCK DOWN)SS ENGINEERED SOLID SURFACESTSTONESTLSTAINLESS STEELSTRUC STRUCTURE ABOVEVCTVINYL COMPOSITE TILEWCVINYL WALL COVERINGWDWOOD-LOOK ALUMINUM SLATS AND BATTENSWPSCREEN WALL
NOTE: REFER TO FF&E PACKAGE AND SPECIFICATION BOOK FOR FURNITURE AND FINISH SPECIFICATIONS
FINISH LEGEND
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 992161ST FLOOR FINISH PLAN- EAST WING
A-132
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
1/8" = 1'-0"11ST FLOOR FLOOR FINISH PLAN - EAST WING
0'4' 8'16'
SCALE: 1/8" = 1'-0"
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
REVISION SCHEDULE
# DESCRIPTION DATE
2 ADDENDUM 2 6/21/2024
2
2
W/DW/D5
3
3.1
6.1
2.1
D
C.1EC
C
B
B
1
8.1
9
4
1.1
A
A
/1 A-134/1 A-134
619 SF
KING1-BEDROOM
X02
716 SF
KING1-BEDROOM
ENLARGED
X01
402 SF
EFFICIENCYENLARGED
X03420 SF
KING STUDIO
X04
58 SF
BALCONY
X01A
58 SF
BALCONY
X02A
420 SF
KING STUDIO
X16
420 SF
KING STUDIO
X18420 SF
KING STUDIO
X20422 SF
KING STUDIO
X14
568 SF
DOUBLE
QUEENENLARGED
X12
541 SF
DOUBLE
QUEEN
X10
355 SF
EFFICIENCY
X08
356 SF
EFFICIENCY
X05
497 SF
LINENS &
HOUSEKEEPING
X09
255 SF
ENGINEERINGOFFICE &STORAGE
207
98 SF
PBX/MDF
207A
157 SF
ELEVATOR
LOBBY
X17
191 SF
STAIR 1
X06
1,746 SF
GUESTCORRIDOR
X15
2
EFFICIENCYX07353 SF
A-419A1
7
8
6
10
A-4481
A-448
8
CPT-10
CPT-10
CPT-14
VCT-01
VCT-01
VCT-01
ACT ACOUSTIC CEILING TILEASALUMINUM STOREFRONTCGCORNER GUARDCONC CONCRETE, UNFINISHEDCPCARPETCPTCARPET TILECSCONCRETE, FINISHEDGWBGYPSUM WALL BOARDFCFIBER CEMENTFRPFIBERGLASS-REINFORCEDPLASTICMR GWB MOISTURE-RESISTANT GWBPFPRE-FINISHED DOORPLPLASTIC LAMINATEPTPAINT/POWDER COATQTQUARRY TILERBRUBBER BASERESRESILIENT TILE FLOORSCSTAMPED CONCRETESFSPECIALTY FINISH (KNOCK DOWN)SS ENGINEERED SOLID SURFACESTSTONESTLSTAINLESS STEELSTRUC STRUCTURE ABOVEVCTVINYL COMPOSITE TILEWCVINYL WALL COVERINGWDWOOD-LOOK ALUMINUM SLATS AND BATTENSWPSCREEN WALL
NOTE: REFER TO FF&E PACKAGE AND SPECIFICATION BOOK FOR FURNITURE AND FINISH SPECIFICATIONS
FINISH LEGEND
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216TYPICAL 2ND-5THFLOOR FINISH PLAN -WEST WING
A-133
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
1/8" = 1'-0"1TYPICAL 2ND-5TH FLOOR FINISH PLAN - WEST WING
0'4' 8'16'
SCALE: 1/8" = 1'-0"
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
REVISION SCHEDULE
# DESCRIPTION DATE
2 ADDENDUM 2 6/21/2024
2
2
2
5
C.1
F
F
G
G M
L.1
E
11
9
4
K N P Q
/1 A-133/1 A-133
420 SF
KING STUDIO
X19
420 SF
KING STUDIO
X21
420 SF
KING STUDIO
X23
420 SF
KING STUDIO
X25354 SF
EFFICIENCY
X27 353 SF
EFFICIENCY
X29
354 SF
EFFICIENCY
X31 353 SF
EFFICIENCY
X33
540 SF
DOUBLEQUEEN
X35
426 SF
KING STUDIO
X37
420 SF
KING STUDIO
X18
420 SF
KING STUDIO
X20
536 SF
DOUBLE
QUEEN
X22
536 SF
DOUBLEQUEEN
X24
420 SF
KING STUDIO
X26
354 SF
EFFICIENCY
X28 420 SF
KING STUDIO
X30
543 SF
DOUBLEQUEEN
X36
483 SF
KING STUDIO
ADA-M-T
X38
157 SF
ELEVATORLOBBY
X17
353 SF
EFFICIENCY
X34
1,746 SF
GUESTCORRIDOR
X15
68 SF
ELEV 1
111
64 SF
ELEV 2
113
58 SF
BALCONY
X19A
58 SF
BALCONY
X21A
58 SF
BALCONY
X23A
58 SF
BALCONY
X25A
57 SF
BALCONY
X37A
57 SF
BALCONY
X35A
226 SF
STAIR 2
X32
A-411A
1
7
8
6
10
H
HJ
A-4506
A-451
3
L
CPT-10
CPT-14
CPT-10
VCT-01
ELECTRICAL
X15A
?
?
ACT ACOUSTIC CEILING TILEASALUMINUM STOREFRONTCGCORNER GUARDCONC CONCRETE, UNFINISHEDCPCARPETCPTCARPET TILECSCONCRETE, FINISHEDGWBGYPSUM WALL BOARDFCFIBER CEMENTFRPFIBERGLASS-REINFORCEDPLASTICMR GWB MOISTURE-RESISTANT GWBPFPRE-FINISHED DOORPLPLASTIC LAMINATEPTPAINT/POWDER COATQTQUARRY TILERBRUBBER BASERESRESILIENT TILE FLOORSCSTAMPED CONCRETESFSPECIALTY FINISH (KNOCK DOWN)SS ENGINEERED SOLID SURFACESTSTONESTLSTAINLESS STEELSTRUC STRUCTURE ABOVEVCTVINYL COMPOSITE TILEWCVINYL WALL COVERINGWDWOOD-LOOK ALUMINUM SLATS AND BATTENSWPSCREEN WALL
NOTE: REFER TO FF&E PACKAGE AND SPECIFICATION BOOK FOR FURNITURE AND FINISH SPECIFICATIONS
FINISH LEGEND
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216TYPICAL 2ND-5THFLOOR FINISH PLAN -EAST WING
A-134
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
1/8" = 1'-0"1TYPICAL 2ND-5TH FLOOR FINISH PLAN - EAST WING
0'4' 8'16'
SCALE: 1/8" = 1'-0"
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
REVISION SCHEDULE
# DESCRIPTION DATE
2 ADDENDUM 2 6/21/2024
2
FLOOR 10' - 0"
FLOOR 216' - 0"
FLOOR 327' - 0"
FLOOR 438' - 0"
FLOOR 549' - 0"
MAIN ROOF61' - 2"
D C.1FGML.1 E
BO ROOF STRUC.60' - 0"
LOW PARAPET63' - 10"
MIDDLE PARAPET65' - 10"
HIGH PARAPET69' - 10"
C B
SITE-0' - 6"
2
A-302
MAX BLDG HEIGHT71' - 2"16' - 0"11' - 0" 11' - 0" 11' - 0" 11' - 0"71' - 2"1
A-302
AKNPQHJ
2
A-301
L
1
A-507
XE-B XE-CXE-C
XS-F
XS-F
XE-D XE-AXE-A
XE-B
XE-D
XE-CXS-F
XE-AXE-B
XE-C
XS-F
XE-B
XE-C
W-K
W-K
W-K
W-KW-H
W-H
W-H
W-HW-C
W-C
W-C
W-CW-H
W-K
W-H
W-H
W-K
W-K
W-K
W-K
W-C
W-C
W-C
W-CW-K D-G04W-KD-G04 D-G04 D-G04
W-K D-G04W-KD-G04 D-G04A D-G04
W-K D-G04W-KD-G04 D-G04 D-G04
W-K D-G04W-KD-G04 D-G04 D-G04
D-G04W-KW-KD-G04
D-G04W-KW-KD-G04
D-G04W-KW-KD-G04
D-G04W-KW-KD-G04
W-H
W-H
W-H
W-HW-H
W-H
W-H
W-HW-H
W-H
W-H
W-HW-H
W-H
W-H
W-HW-KD-G04W-KD-G04
D-141W-HW-HW-HW-KD-G04W-KD-G04
D-G04D-G04
D-G04D-G04
D-G04D-G04
W-KW-K
W-KW-K
W-KW-K
CW-A1CW-A2CW-B
D-121
CW-C CW-G CW-G CW-G CW-G CW-G
XS-F
XE-AXE-A
XS-F
PC-B XS-FPC-B
XE-A
XE-B
XE-C
XE-C
PT-E
PT-E
PT-E
PT-E
PT-E
PT-E
PT-E
PT-E
PT-EPT-E PT-EPT-E
PT-E
PT-E
PT-EPT-E
PT-E
PT-E
PT-E
PT-E
PT-E
PT-E
PC-04
PC-04
PC-04
PC-04
PC-04
PT-E
PC-04
PC-04
PC-04
PC-04
PC-04
PC-04
PC-04
PC-04
PC-04
PC-04
PC-04
PC-04
PC-04
FLOOR 10' - 0"
FLOOR 216' - 0"
FLOOR 327' - 0"
FLOOR 438' - 0"
FLOOR 549' - 0"
MAIN ROOF61' - 2"
533.16.12.1
1
A-301
BO ROOF STRUC.60' - 0"
LOW PARAPET63' - 10"
MIDDLE PARAPET65' - 10"
HIGH PARAPET69' - 10"
SITE-0' - 6"
1
3
A-302
MAX BLDG HEIGHT71' - 2"71' - 2"11' - 0"11' - 0"11' - 0"11' - 0"16' - 0"165' - 8 1/2"
118.194 1.1278610
1
A-505
XE-CXE-AXE-BXE-B
XE-CXE-CXE-A
XS-FXE-B XS-F
XE-A
XS-F
XS-F
XE-A
XE-BXW-G
XS-F
W-H W-H
W-H
W-HW-H
W-H
W-H W-H
CW-F CW-F
D-101D-139B
W-C
W-C
W-C
W-CW-H
W-H
W-H
W-H
W-H
W-H
W-H
PT-E
PC-04
PT-E
PT-E
PT-E
PC-04
PC-04
PC-04
PT-E
PT-E
PT-E
PT-E
PT-E
PT-E
PT-E
PC-04
PC-04
PC-04
PC-04
PC-04
PT-E
D-104
PC-B
CW-L
XS-F
XE-B
XE-B
XE-C
XE-C
PT-E
PT-EPT-A
PC-04
XS-F
13' - 9" CLEARPC-B
EQEQ
XE-C
XS-F
XE-A/ PT-A / PC-ABEIGE EIFS/MATCH SHERWIN-WILLIAMSPAINT / POWDER-COAT SW6154 NACRE (263-C2)
XE-B / PT-B / PC-BLIGHT BROWN EIFS / MATCH SHERWIN-WILLIAMSPAINT / POWDER-COAT SW7153 SANDERLING (248-C5)
GRAPHIC EXTERIOR MATERIAL LEGEND
XE-C/ PT-C / PC-CMID BROWN EIFS /MATCH SHERWIN-WILLIAMSPAINT / POWDER-COAT SW7525 TREE BRANCH (288-C7)
XE-D / PT-D / PC-DRED BROWN EIFS / MATCH SHERWIN-WILLIAMSPAINT / POWDER-COAT SW6118 LEATHER BOUND (291-C7)
XE-E/ PT-E / PC-EDARK BROWN EIFS / MATCH SHERWIN-WILLIAMSPAINT / POWDER-COAT SW7510 CHATEAU BROWN (242-C7)
XS-FMANUFACTURED STONE CULTURED STONE VENEER CLADDING COUNTRY LEDGESTONEASHFALL
XW-GWOOD-LOOK KNOTWOOD, 6" CLADDINGALUMINUM CLADDING WESTERN RED CEDAR
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216BUILDING ELEVATIONS
A-201
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
3/32" = 1'-0" Reference: 1 / A-101
1NORTH ELEVATION
3/32" = 1'-0" Reference: 1 / A-101
2EAST ELEVATION
3
0'6' 12'24'
SCALE: 3/32" = 1'-0"
1 2 TYP.
4TYP.
5TYP.6TYP.
7TYP.
8 TYP.
12 TYP.
2215TYP.
2 TYP.6TYP.8TYP.
12 TYP.
16
102115TYP.
9
11
11
13212110 7TYP.21
2121
2020
KEYNOTES - ELEVATIONS
1 EMERGENCY OVERFLOW ROOF SCUPPER
2 VISIBILE CONTROL JOINT. LOCATE VISIBLE AS INDICATED ONDRAWINGS. ADDITIONAL NECESSARY CONTROL JOINTS TO BEINVISIBILE AND LOCATED PER MANUFACTURER'SSPECIFICATIONS.
3 PERMANENT ACCESS DOORS TO INTERIOR OF ALL PARAPETSWHERE SIGNS ARE LOCATED TO BE PROVIDED BYCONTRACTOR. CONTRACTOR TO FURNISH AND CONNECTPRIMARY ELECTRICAL SERVICE INSIDE PARAPET WALL.COORDINATE SERVICE FOR SIGN WITH ELECTRICAL.
4 PTAC VENT. WHERE PTAC VENT IS NOT INTEGRATED INTOWINDOW SYSTEM, MATCH FINISH COLOR TO ADJACENTSURFACE. VERIFY EACH COLORS WITH ARCHITECT.
5 PRE-FINISHED ALUMINUM WINDOWS.
6 PRE-FINISHED ALUMINUM WINDOWS WITH INTEGRATED PTACLOUVERS.
7 ALUMINUM STOREFRONT
8 PARAPET
9 SIGN INDICATING CLEAR HEIGHT UNDER PORTE-COCHERE.COLOR TO CONTRAST WITH BACKGROUND. AHJ TO MAKEFINAL DETERMINATION ON FORMAT, LOCATION, COLOR ANDSIZE.
10 INSULATED, GALVANIZED, HOLLOW METAL DOOR AND FRAME.
11 COVERED SECONDARY ENTRY
12 EXTERIOR WALL SCONCE FOR BALCONY
13 DRYER AND DRYER ROOM VENTS.
14 AUTOMATIC ALUMINUM SLIDING DOOR
15 DECORATIVE CONCRETE CAP AT MATERIAL CHANGE.
16 ALL ROOFTOP EQUIPMENT TO BE ADAQUATELY SCREENEDFROM PUBLIC VIEW.
17 GUEST LAUNDRY ROOM VENTING.
18 ROOF HATCH AND SAFETY RAILING/GATE.
19 BUILDING ADDRESS NUMBER, 14" TALL TEXT. COLOR TOCONTRAST WITH BACKGROUND. AHJ TO MAKE FINALDETERMINATION ON FORMAT, LOCATION, COLOR AND SIZE.
20 WATERPROOF GFCI EXTERIOR OUTLET IN LOCKABLE BOX.
21 FREEZEPROOF HOSE BIBB IN LOCKABLE BOX.
22 KITCHEN HOOD VENT
23 KNOX BOX. FINAL LOCATION, MOUNTING HEIGHT, KEYING, SIZETO BE DETERMINED BY AHJ.
24 HOT WATER ROOM VENTING.
4. GUESTROOMS OR PUBLIC SPACES WITH SIGNAGE ON EXTERIORWALLS MUST HAVE ELECTRICAL PENETRATIONS AND/ORREMOTETRANSFORMERS COORDINATED AND/OR INSTALLED PRIOR TO...
3. RACEWAYS / WIREWAYS ARE NOT ALLOWED
2. ELECTRICAL AND FINAL CONNECTION BY CONTRACTOR.ELECTRICAL REQUIREMENTS MAY BE OBTAINED FROM SIGNCOMPANY.
1. MINIMUM 5/8" PLYWOOD BACKERBOARD REQUIRED AT SIGNLOCATIONS. AREA SHOULD COVER ENTIRE LENGTH AND HEIGHTOF FASCIA OR SPACE AVAILABLE FOR SIGN.
GENERAL NOTES - BUILDING SIGNAGE
4. SEE ELECTRICAL FOR EXTERIOR LIGHTING.
3. USE HIGH-IMPACT MESH AT BOTTOM 8' AROUND ENTIREBUILDING WHERE EIFS IS INSTALLED.
2. ALL EXTERIOR VENTS, GRILLES, MECHANICAL LOUVERS ANDEXTERIOR HOLLOW METAL DOORS TO BE FINISHED TO MATCHADJACENT EXTERIOR MATERIAL.
1. LOCATE ALL ROOFTOP EQUIPMENT SO THAT IT IS EITHER OUTOF SIGHTLINES OR ADAQUATELY SCREENED.
GENERAL NOTES - ELEVATIONS
20
2020 21 20 20
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
Revision Schedule
Number Description Date
FLOOR 10' - 0"
FLOOR 216' - 0"
FLOOR 327' - 0"
FLOOR 438' - 0"
FLOOR 549' - 0"
MAIN ROOF61' - 2"
DC.1FG ML.1E
BO ROOF STRUC.60' - 0"
LOW PARAPET63' - 10"
MIDDLE PARAPET65' - 10"
HIGH PARAPET69' - 10"
CB
SITE-0' - 6"
2
A-302 MAX BLDG HEIGHT71' - 2"11' - 0"11' - 0"11' - 0"11' - 0"16' - 0"71' - 2"1
A-302
A K N P Q
3
A-505
H J
2
A-301
L
1
A-507
XE-B
XE-C
XE-A
XS-FXE-E
XE-BXE-A
XS-F
XW-G
XE-A
XS-F XE-E
XE-B XE-A
XS-F
XE-B
XE-CXS-FXW-G
XE-A
W-BW-BW-B
W-C
W-C
W-C
W-CW-G
W-G
W-G
W-GW-G
W-G
W-G
W-GW-G
W-G
W-G
W-G
W-BW-BCW-D
CW-D
D-122
CW-M
CW-D
W-G
W-G
W-G
W-GW-G
W-G
W-G
W-GW-G
W-G
W-G
W-G W-H
W-H
W-H
W-H
W-BW-B W-B W-G W-H
W-G
W-G
W-G
W-G W-H
W-H
W-H
W-H
W-G
W-G
W-G
W-G
W-G
W-G
W-G
W-G
W-G
W-G
XS-F
PT-E
XS-FXS-F
PC-04
XE-B
XE-A
XE-B
D-G107PC-E
XE-E XE-E XE-E XS-F
XW-G
XS-F
PT-E
PT-E
FLOOR 10' - 0"
FLOOR 216' - 0"
FLOOR 327' - 0"
FLOOR 438' - 0"
FLOOR 549' - 0"
MAIN ROOF61' - 2"
533.16.12.1
1
A-301
BO ROOF STRUC.60' - 0"
LOW PARAPET63' - 10"
MIDDLE PARAPET65' - 10"
HIGH PARAPET69' - 10"
SITE-0' - 6"
1
3
A-302
11' - 0"11' - 0"11' - 0"11' - 0"16' - 0"165' - 8 1/2"
MAX BLDG HEIGHT71' - 2"71' - 2"118.1941.1278610
1
A-505
XE-C
XS-F
XE-A
XE-B
XE-B
XE-C
XE-A
XS-F
XW-G
XS-F
XE-C
D-108AD-106AD-100
W-H
W-H
W-H
W-HW-G
W-G
W-G
W-GW-H
W-H
W-H
W-HW-G
W-G
W-G
W-GW-G
W-G
W-G
W-GW-G
W-G
W-G
W-G
W-BW-BW-BW-BW-BW-A
CW-FCW-FCW-FCW-F
CW-H
PC-BPC-B
PT-EXS-F
XE-CXE-A
XE-BXE-C
XE-B
PT-E
PC-04
PC-C
PT-E
PT-E
PC-04
XS-F
4' - 9"PT-E
PT-E
PT-E
PT-E
PC-04
PC-04
PC-04
EQEQ 17' - 3 1/4"XE-A/ PT-A / PC-ABEIGE EIFS/MATCH SHERWIN-WILLIAMSPAINT / POWDER-COAT SW6154 NACRE (263-C2)
XE-B / PT-B / PC-BLIGHT BROWN EIFS / MATCH SHERWIN-WILLIAMSPAINT / POWDER-COAT SW7153 SANDERLING (248-C5)
GRAPHIC EXTERIOR MATERIAL LEGEND
XE-C/ PT-C / PC-CMID BROWN EIFS /MATCH SHERWIN-WILLIAMSPAINT / POWDER-COAT SW7525 TREE BRANCH (288-C7)
XE-D / PT-D / PC-DRED BROWN EIFS / MATCH SHERWIN-WILLIAMSPAINT / POWDER-COAT SW6118 LEATHER BOUND (291-C7)
XE-E/ PT-E / PC-EDARK BROWN EIFS / MATCH SHERWIN-WILLIAMSPAINT / POWDER-COAT SW7510 CHATEAU BROWN (242-C7)
XS-FMANUFACTURED STONE CULTURED STONE VENEER CLADDING COUNTRY LEDGESTONEASHFALL
XW-GWOOD-LOOK KNOTWOOD, 6" CLADDINGALUMINUM CLADDING WESTERN RED CEDAR
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216BUILDING ELEVATIONS
A-202
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
3/32" = 1'-0" Reference: 1 / A-101
1SOUTH ELEVATION
3/32" = 1'-0" Reference: 1 / A-101
2WEST ELEVATION
0'6' 12'24'
SCALE: 3/32" = 1'-0"
3
3
KEYNOTES - ELEVATIONS
1 EMERGENCY OVERFLOW ROOF SCUPPER
2 VISIBILE CONTROL JOINT. LOCATE VISIBLE AS INDICATED ONDRAWINGS. ADDITIONAL NECESSARY CONTROL JOINTS TO BEINVISIBILE AND LOCATED PER MANUFACTURER'SSPECIFICATIONS.
3 PERMANENT ACCESS DOORS TO INTERIOR OF ALL PARAPETSWHERE SIGNS ARE LOCATED TO BE PROVIDED BYCONTRACTOR. CONTRACTOR TO FURNISH AND CONNECTPRIMARY ELECTRICAL SERVICE INSIDE PARAPET WALL.COORDINATE SERVICE FOR SIGN WITH ELECTRICAL.
4 PTAC VENT. WHERE PTAC VENT IS NOT INTEGRATED INTOWINDOW SYSTEM, MATCH FINISH COLOR TO ADJACENTSURFACE. VERIFY EACH COLORS WITH ARCHITECT.
5 PRE-FINISHED ALUMINUM WINDOWS.
6 PRE-FINISHED ALUMINUM WINDOWS WITH INTEGRATED PTACLOUVERS.
7 ALUMINUM STOREFRONT
8 PARAPET
9 SIGN INDICATING CLEAR HEIGHT UNDER PORTE-COCHERE.COLOR TO CONTRAST WITH BACKGROUND. AHJ TO MAKEFINAL DETERMINATION ON FORMAT, LOCATION, COLOR ANDSIZE.
10 INSULATED, GALVANIZED, HOLLOW METAL DOOR AND FRAME.
11 COVERED SECONDARY ENTRY
12 EXTERIOR WALL SCONCE FOR BALCONY
13 DRYER AND DRYER ROOM VENTS.
14 AUTOMATIC ALUMINUM SLIDING DOOR
15 DECORATIVE CONCRETE CAP AT MATERIAL CHANGE.
16 ALL ROOFTOP EQUIPMENT TO BE ADAQUATELY SCREENEDFROM PUBLIC VIEW.
17 GUEST LAUNDRY ROOM VENTING.
18 ROOF HATCH AND SAFETY RAILING/GATE.
19 BUILDING ADDRESS NUMBER, 14" TALL TEXT. COLOR TOCONTRAST WITH BACKGROUND. AHJ TO MAKE FINALDETERMINATION ON FORMAT, LOCATION, COLOR AND SIZE.
20 WATERPROOF GFCI EXTERIOR OUTLET IN LOCKABLE BOX.
21 FREEZEPROOF HOSE BIBB IN LOCKABLE BOX.
22 KITCHEN HOOD VENT
23 KNOX BOX. FINAL LOCATION, MOUNTING HEIGHT, KEYING, SIZETO BE DETERMINED BY AHJ.
24 HOT WATER ROOM VENTING.
4. GUESTROOMS OR PUBLIC SPACES WITH SIGNAGE ON EXTERIORWALLS MUST HAVE ELECTRICAL PENETRATIONS AND/ORREMOTETRANSFORMERS COORDINATED AND/OR INSTALLED PRIOR TO...
3. RACEWAYS / WIREWAYS ARE NOT ALLOWED
2. ELECTRICAL AND FINAL CONNECTION BY CONTRACTOR.ELECTRICAL REQUIREMENTS MAY BE OBTAINED FROM SIGNCOMPANY.
1. MINIMUM 5/8" PLYWOOD BACKERBOARD REQUIRED AT SIGNLOCATIONS. AREA SHOULD COVER ENTIRE LENGTH AND HEIGHTOF FASCIA OR SPACE AVAILABLE FOR SIGN.
GENERAL NOTES - BUILDING SIGNAGE
4. SEE ELECTRICAL FOR EXTERIOR LIGHTING.
3. USE HIGH-IMPACT MESH AT BOTTOM 8' AROUND ENTIREBUILDING WHERE EIFS IS INSTALLED.
2. ALL EXTERIOR VENTS, GRILLES, MECHANICAL LOUVERS ANDEXTERIOR HOLLOW METAL DOORS TO BE FINISHED TO MATCHADJACENT EXTERIOR MATERIAL.
1. LOCATE ALL ROOFTOP EQUIPMENT SO THAT IT IS EITHER OUTOF SIGHTLINES OR ADAQUATELY SCREENED.
GENERAL NOTES - ELEVATIONS
1
15TYP.
16
1
1
21
19
21
21 2020
20202023241720115TYP.6TYP.
12TYP.
2TYP.
2TYP.
6TYP.5TYP.
1010
10
7TYP.
1816
7TYP.
8TYP.
8 TYP.
14
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
Revision Schedule
Number Description Date
FLOOR 10' - 0"
FLOOR 216' - 0"
FLOOR 327' - 0"
FLOOR 438' - 0"
FLOOR 549' - 0"
MAIN ROOF61' - 2"
C.1FGML.1 E
LOW PARAPET63' - 10"
MIDDLE PARAPET65' - 10"
HIGH PARAPET69' - 10"
C B
SITE-0' - 6"
2
A-302
ELEV 1
111
EMPLOYEEROOM
110
DOUBLEQUEEN
210
DOUBLEQUEEN
310
DOUBLE
QUEEN
410
DOUBLEQUEEN
510
LINENS &HOUSEKEEPING
509
LINENS &HOUSEKEEPING
409
LINENS &HOUSEKEEPING
309
BOH LAUNDRY
105ELEVATORLOBBY
117
ELEVATORLOBBY
217
ELEVATORLOBBY
317
ELEVATOR
LOBBY
417
ELEVATORLOBBY
517
KING STUDIO
519
KING STUDIO
419
KING STUDIO
319
KING STUDIO
219
LOBBY
121
FOOD PREP
123
EFFICIENCY
129
EFFICIENCY
131
EFFICIENCY
133
DOUBLEQUEEN
135
KING STUDIO
137
KING STUDIO
237
KING STUDIO
337
KING STUDIO
437
KING STUDIO
537
DOUBLEQUEEN
535
DOUBLE
QUEEN
435
DOUBLEQUEEN
335
DOUBLE
QUEEN
235
EFFICIENCY
533
EFFICIENCY
433
EFFICIENCY
333
EFFICIENCY
233
EFFICIENCY
231
EFFICIENCY
331
EFFICIENCY
431
EFFICIENCY
531
EFFICIENCY
529
EFFICIENCY
429
EFFICIENCY
329
EFFICIENCY
229
EFFICIENCY
527
EFFICIENCY
427
EFFICIENCY
327
EFFICIENCY
227
KING STUDIO
225
KING STUDIO
325
KING STUDIO
425
KING STUDIO
525
KING STUDIO
523
KING STUDIO
423
KING STUDIO
323
KING STUDIO
223
KING STUDIO
421
KING STUDIO
321
KING STUDIO
521
KING STUDIO
221
16' - 0"11' - 0" 11' - 0" 11' - 0"
MAX BLDG HEIGHT71' - 2"71' - 2"LINENS &HOUSEKEEPING
209
1
A-302
AKNPQHJ2
A-301
L
12' - 2"1
A-507
FLOOR 10' - 0"
FLOOR 216' - 0"
FLOOR 327' - 0"
FLOOR 438' - 0"
FLOOR 549' - 0"
MAIN ROOF61' - 2"
533.16.1 2.1
1
A-301
SITE-0' - 6"
1
3
A-302
MAX BLDG HEIGHT71' - 2"
118.194 1.1278610
DOUBLE
QUEEN
524
KING STUDIO
523
LOBBY
121VESTIBULE
122
DOUBLE
QUEEN
424
DOUBLE
QUEEN
324
DOUBLEQUEEN
224
KING STUDIO
423
KING STUDIO
323
KING STUDIO
223
A-5053 10' - 0"12' - 2"11' - 0"11' - 0"11' - 0"16' - 0"0' - 6"71' - 2"A-5071Sim
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216BUILDING SECTIONS
A-301
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
0'6' 12'24'
SCALE: 3/32" = 1'-0"
3/32" = 1'-0" Reference: 1 / A-101
1LONGITUDINAL SECTION THROUGH LOBBY
3/32" = 1'-0" Reference: 1 / A-101
2CROSS SECTION THROUGH LOBBY
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
Revision Schedule
Number Description Date
FLOOR 10' - 0"
FLOOR 216' - 0"
FLOOR 327' - 0"
FLOOR 438' - 0"
FLOOR 549' - 0"
MAIN ROOF61' - 2"
53
1
A-301
LOW PARAPET63' - 10"
MIDDLE PARAPET65' - 10"
HIGH PARAPET69' - 10"
SITE-0' - 6"
1
3
A-302
MAX BLDG HEIGHT71' - 2"
1194278610
1
A-505
KING1-BEDROOMENLARGED
501
KING
1-BEDROOMENLARGED
401
KING1-BEDROOM
ADA-M-T
301
KING1-BEDROOMENLARGED
201
EFFICIENCYADA-M-T
503
EFFICIENCYADA-M-RI
403
EFFICIENCYENLARGED
303
EFFICIENCYENLARGED
203
EFFICIENCY
505
EFFICIENCY
405
EFFICIENCY
305
EFFICIENCY
205
EFFICIENCY
507
EFFICIENCY
407
EFFICIENCY
307
ENGINEERINGOFFICE &STORAGE
207
PBX/MDF
207A
LINENS &HOUSEKEEPING
509
LINENS &HOUSEKEEPING
409
LINENS &HOUSEKEEPING
309
KING STUDIO
516
KING STUDIO
416
KING STUDIO
316
KING STUDIO
216
LINENS &HOUSEKEEPING
209
LINENSTORAGE
109
MEN'SRESTROOM
116
WOMEN'SRESTROOM
115
PUBLICCORRIDOR
100
GUESTCORRIDOR
215
GUESTCORRIDOR
315
GUESTCORRIDOR
415
GUESTCORRIDOR
515
BOH LAUNDRY
105
POOL &SPLASH PAD
101
FLOOR 10' - 0"
FLOOR 216' - 0"
FLOOR 327' - 0"
FLOOR 438' - 0"
FLOOR 549' - 0"
MAIN ROOF61' - 2"
DFGME
LOW PARAPET63' - 10"
MIDDLE PARAPET65' - 10"
HIGH PARAPET69' - 10"
C B
SITE-0' - 6"
2
A-302
2,152 SF
POOL &SPLASH PAD
101
420 SF
KING STUDIO
204
402 SF
EFFICIENCY
ENLARGED
203
420 SF
KING STUDIO
304
420 SF
KING STUDIO
404
420 SF
KING STUDIO
504
402 SF
EFFICIENCY
ENLARGED
303
399 SF
EFFICIENCY
ADA-M-RI
403
399 SF
EFFICIENCYADA-M-T
503
16' - 0"11' - 0" 11' - 0" 11' - 0"
MAX BLDG HEIGHT71' - 2"
58' - 5 1/4"71' - 2"204 SF
POOL MEP
103
1
A-302
AKNPQHJ
2
A-301
L
12' - 2"POOLRESTROOM
102
FLOOR 10' - 0"
FLOOR 216' - 0"
FLOOR 327' - 0"
FLOOR 438' - 0"
FLOOR 549' - 0"
MAIN ROOF61' - 2"
1
A-301
LOW PARAPET63' - 10"
MIDDLE PARAPET65' - 10"
SITE-0' - 6"
EFFICIENCY
131
EFFICIENCY
231
EFFICIENCY
331
EFFICIENCY
431
EFFICIENCY
531
ROOF ACCESS
539STAIR 2
532
STAIR 2
432
STAIR 2
332
STAIR 2
232
STAIR 2
132 11' - 0"11' - 0"11' - 0"16' - 0"9786 10
12' - 2" 3/32" = 1'-0" Reference: 1 / A-101
2 CROSS SECTION THROUGH GUESTROOMS IN EAST WING
3/32" = 1'-0" Reference: 1 / A-101
3CROSS SECTION THROUGH POOL
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216BUILDING SECTIONS
A-302
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
0'6' 12'24'
SCALE: 3/32" = 1'-0"
3/32" = 1'-0" Reference: 1 / A-101
1LONGITUDINAL SECTION THROUGH POOL
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
Revision Schedule
Number Description Date
XE7
G-005
G-004
2,116 SF
PET AREA
004
OP-701
OF-713
10' - 0"5' - 0"4' - 0"26' - 0 1/2"90.00°26' - 1 3/4"20' - 7 1/2"12' - 11 3/4"90.00°90.00°129.01°90.00°133.26°
64
'
-
6
1
/
2
"
5' - 10 3/4"38' - 1 1/2"OF-713
OP-701
MIN. 8' - 0"MIN. 8' - 0"20' - 0"3' - 0"4' - 0"3' - 6"0' - 6"4' - 6"
MIN. 9' - 0" TYP.18' - 0" TYP.TYP.3' - 0"CLR. MIN.
3' - 0"8.33 % MAX.3' - 6"6' - 0" TYP.
4' - 0"6' - 0"4' - 0"SITE LEGEND
DUPLEX OUTLET - GFCI
DUPLEX OUTLET - WEATHERPROOF/GFCI
COMBINED SMOKE/CARBON MONOXIDE DETECTOR
OUTDOOR KITCHEN PENDANT (OF-704)
FREEZEPROOF WALL HYDRANT
POLE HYDRANT
6" ROUND BOLLARD
WP
S/CO
XE-A / PT-A / PC-ABEIGE EIFS/MATCH SHERWIN-WILLIAMSPAINT / POWDER-COAT SW6154 NACRE (263-C2)
XE-B / PT-B / PC-BLIGHT BROWN EIFS / MATCH SHERWIN-WILLIAMSPAINT / POWDER-COAT SW7153 SANDERLING (248-C5)
GRAPHIC EXTERIOR MATERIAL LEGEND
XE-C / PT-C / PC-C
MID BROWN EIFS /MATCH SHERWIN-WILLIAMSPAINT / POWDER-COAT SW7525 TREE BRANCH (288-C7)
XE-D / PT-D / PC-DRED BROWN EIFS / MATCH SHERWIN-WILLIAMSPAINT / POWDER-COAT SW6118 LEATHER BOUND (291-C7)
XE-E / PT-E / PC-E
DARK BROWN EIFS / MATCH SHERWIN-WILLIAMSPAINT / POWDER-COAT SW7510 CHATEAU BROWN (242-C7)
XS-FMANUFACTURED STONE CULTURED STONE VENEER CLADDING COUNTRY LEDGESTONEASHFALL
XW-G / WD-1WOOD-LOOK KNOTWOOD, 6" CLADDINGALUMINUM CLADDING WESTERN RED CEDAR
1/4" = 1'-0" Reference: 1 / A-010
1PET EXERCISE AND RELEIF AREA
North Side of Building along Property Line
1/4" = 1'-0" Reference: 1 / A-010
2EV PARKING STALL ENLARGED PLAN
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216ENLARGED EV PARKING& PET RELIEF AREA
A-401
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
0'2' 4'8'
SCALE: 1/4" = 1'-0"
4
11
19
KEYNOTES - ENLARGED SITE PLANS
1 CONCRETE WHEEL STOP. PROVIDE AT EACH EV CHARGING/EV READY STALL, ACCESSIBLE STALL ANDSTALL ADJACENT TO AN ACCESSIBLE ROUTE.
2 6" BOLLARD
3 STANDARD STALL - 9' WIDE BY 18' LONG
4 EMERGENCY GENERATOR. SEE ELECTRICAL. PROVIDE DENSE LANDSCAPE SCREENING AT GENERATORENCLOSURE.
5 STANDARD EV CHARGING STALL - 9' WIDE BY 18' LONG
6 STRIPING COLORS: ACCESSIBLE (INCLUDING EV) STALL: BLUE, EV CHARGING STALL: GREEN, STANDARDSTALLS: WHITE. VERIFY STRIPING COLORS WITH AHJ.
7 6" THICK CONCRETE SLAB UNDER TRASH ENCLOSURE. EXTEND SLAB 6' BEYOND ENCLOSURE.
8 TRASH AND RECYCLING DUMPSTERS PROVIDED BY OTHER.
9 GUTTER AND DOWNSPOUT. DOWNSPOUT TO CONNECT TO STORM SEWER.
10 AREA DRAIN. CONNECT TO STORM SEWER.
11 4' HIGH ORNAMENTAL IRON FENCE
12 3' HIGH ORNAMENTAL IRON FENCE ON RETAINING WALL EXTENDING 1' ABOVE GRADE
13 FROST-PROOF WALL HYDRANT IN KEYED BOX.
14 POST HYDRANT
15 EV CHARGING STATION SERVING TWO NON-ACCESSIBLE STALLS, CENTER CHARGING STATIONBETWEEN STALLS. VERIFY CLEARANCES AND DIMENSIONS WITH MANUFACTURER INSTALLATIONINSTRUCTIONS.
16 EV CHARGING STATION SERVING ONE ACCESSIBLE AND ONE NON-ACCESSIBLE SPACE. CHARGINGSTATION MUST BE ON LEVEL WITH ACCESS AISLE. VERIFY CLEARANCES AND DIMENSIONS WITHMANUFACTURER INSTALLATION INSTRUCTIONS.
17 8' WIDE AISLE FOR VAN ACCESSIBLE PARKING STALL. PROVIDE SIGNAGE AS REQUIRED. CHARGINGSTATION TO BE ON LEVEL WITH ACCESS AISLE. PROVIDE BOLLARDS IN FRONT OF CHARGING STATION.DO NOT OBSTRUCT ACCESS AISLE WITH BOLLARDS, WHEEL STOPS OR SIGNAGE.
18 ACCESSIBLE PARKING SPACE - VAN ACCESSIBLE AND EV CHARGING STATION. 8' WIDE BY 20' LONG.PROVIDE SIGNAGE FOR ACCESSIBLE PARKING STALL AS REQUIRED. PROVIDE SIGNAGE INDICATING VANACCESSIBLE STALL. PROVIDE SIGN THAT READS, "ELECTRIC VEHICLE PARKING PREFERRED" BELOWACCESSIBILITY SIGNS. PROVIDE CONCRETE WHEEL STOP. ANY VEHICLE WITH AN ACCESSIBLE PARKINGPERMIT MUST BE ALLOWED TO PARK IN THIS SPACE.
19 SEMI-ENCLOSED SMOKING SHELTER GREATER THAN 25' FROM WINDOWS, DOORS OR AIR INTAKEVENTS. PROVIDE BENCH AT ADA ACCESSIBLE HEIGHT, ASH RECEPTACLE AND TRASH CAN. SCREENWITH LANDSCAPING WHERE POSSIBLE.
20 ACCESSIBLE CURB RAMP TO MEET ALL ACCESSIBILITY REQUIREMENTS. MAXIMUM SLOPE OF RUN 1:12.
21 EMERGENCY SHUT-OFF FOR FIRE PITS AND GAS GRILLS. ENSURE BUTTON IS MOUNTED WITHIN ADAREACH RANGE AND CLEARLY MARKED.
22 TRELLIS ABOVE
23 SURFACE-MOUNTED UTILITY LIGHT
25 ACCESSIBLE ROUTE. MARK WHERE ROUTE CROSSES VEHICULAR TRAFFIC.
29 STAMPED, COLORED CONCRETE APRON AND COURTYARD
30 CANOPY/BALCONY ABOVE
31 40'x100' WEDDING AREA, GREATER THAN 20' FROM BUILDING WALLS. OWNER TO SECURE EVENT PERMITWITH SPOKANE VALLEY FIRE DEPARTMENT PRIOR TO EVENTS.
32 ALL EQUIPMENT (INCLUDING DRYER VENTS) MUST BE SCREENED WITH LANDSCAPING OR OTHERMEANS.
20
1817
25
2
16
111
1
15
1 1
12
11
33555
6
6
8. CATCH BASINS ARE TO BE PLACED SO AS NOT TO INTERFERE WITH DESIGNATED ACCESSIBLE ROUTES.
7. 10% OF NON-PAVED, NON-COVERED AREA OF PROJECT SITE TO BE LANDSCAPED.
6. INSTALL ACCENT PLANTINGS OF ANNUALS AND PERENNIALS AT MAIN ENTRANCE, BUILDING ENTRY, AND SIGNAGEAREAS, AND BACKYARD.
5. SOD ALL AREAS NOT WITHIN PLANTING BEDS.
4. IRRIGATE ALL LANDSCAPED AREAS WITH AUTOMATIC UNDERGROUND SPRINKLER SYSTEM.
3. BUILDING UPLIGHTING SHALL NOT BE OBSTRUCTED BY LANDSCAPE PLANTINGS.
2. REFER TO HILTON SIGNAGE STANDARDS, BRAND STANDARDS AND HILTON marKIT FOR ADDITIONAL INFORMATIONAND PRECISE SIGNAGE REQUIREMENTS. ELECTRICAL FOR BUILDING SIGNAGE AND MONUMENT SIGNAGE SHALLBE PROVIDED AND CONNECTED BY THE CONTRACTOR.
1. COORDINATE LIGHTING LOCATIONS WITH LANDSCAPE PLANTINGS
GENERAL NOTES- SITE
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
Revision Schedule
Number Description Date
S/CO
16' - 5 3/4"15' - 11 3/4"23' - 5 3/4"
6' - 0"
4
A-402
42' - 3"6' - 0"D-001
D-001A
G-002G-002A
EQEQEQEQEQEQEQEQ
0' - 2"TYP.0' - 6"
10' - 0" TYP.
0' - 6"0' - 6"3' - 3"EQEQEQCLEAR AREA MIN.
10' - 0" X 12' - 0"EQEQEQEQEQEQ
XE5
XE5
XE6
XE5
EQEQEQ16' - 5 3/4"15' - 11 3/4"MIN. 17/64" / 1'-0" TYP.MIN. 1/4" / 1'-0" TYP.GFCI
GFCI
GFCIGFCI
GFCI
GFCI
WP
CS-01
CONC
CONC
263 SF
OUTDOORSTORAGE
001
385 SF
OPEN TRASHENCLOSURE
002
10' - 0"G-002AG-002
D-001A
D-001
XE5
XE6
STORAGE/TRASH-3' - 0"
WD-1WD-1
XE-B
XE-B
XW-GXW-G
PC-BPC-B
1/4" / 1'-0"8' - 2"8' - 6"10' - 0"9' - 1 1/2"3' - 0"2' - 0"STORAGE/TRASH-3' - 0"TYP.2' - 0"XE5XE6XE5
4
A-402EQEQ 4' - 0"4' - 0"CL-B38' - 6"
EQ EQ
ACT ACOUSTIC CEILING TILEASALUMINUM STOREFRONTCGCORNER GUARDCONC CONCRETE, UNFINISHEDCPCARPETCPTCARPET TILECSCONCRETE, FINISHEDGWBGYPSUM WALL BOARDFCFIBER CEMENTFRPFIBERGLASS-REINFORCEDPLASTICMR GWB MOISTURE-RESISTANT GYPSUM WALL BOARDPLPLASTIC LAMINATEPTPAINT/POWDER COATQTQUARRY TILERBRUBBER BASERESRESILIENT TILE FLOORSCSTAMPED CONCRETESFSPECIALTY FINISH (KNOCK DOWN)SS ENGINEERED SOLID SURFACESTSTONESTLSTAINLESS STEELSTRUC STRUCTURE ABOVEVCTVINYL COMPOSITE TILEWCVINYL WALL COVERINGWDWOOD-LOOK ALUMINUM SLATS AND BATTENSWPSCREEN WALL
NOTE: REFER TO FF&E PACKAGE AND SPECIFICATION BOOK FOR FURNITURE AND FINISH SPECIFICATIONS
FINISH LEGEND
SITE LEGEND
DUPLEX OUTLET - GFCI
DUPLEX OUTLET - WEATHERPROOF/GFCI
COMBINED SMOKE/CARBON MONOXIDE DETECTOR
OUTDOOR KITCHEN PENDANT (OF-704)
FREEZEPROOF WALL HYDRANT
POLE HYDRANT
6" ROUND BOLLARD
WP
S/CO
XE-A / PT-A / PC-ABEIGE EIFS/MATCH SHERWIN-WILLIAMSPAINT / POWDER-COAT SW6154 NACRE (263-C2)
XE-B / PT-B / PC-BLIGHT BROWN EIFS / MATCH SHERWIN-WILLIAMSPAINT / POWDER-COAT SW7153 SANDERLING (248-C5)
GRAPHIC EXTERIOR MATERIAL LEGEND
XE-C / PT-C / PC-CMID BROWN EIFS /MATCH SHERWIN-WILLIAMSPAINT / POWDER-COAT SW7525 TREE BRANCH (288-C7)
XE-D / PT-D / PC-DRED BROWN EIFS / MATCH SHERWIN-WILLIAMSPAINT / POWDER-COAT SW6118 LEATHER BOUND (291-C7)
XE-E / PT-E / PC-EDARK BROWN EIFS / MATCH SHERWIN-WILLIAMSPAINT / POWDER-COAT SW7510 CHATEAU BROWN (242-C7)
XS-FMANUFACTURED STONE CULTURED STONE VENEER CLADDING COUNTRY LEDGESTONEASHFALL
XW-G / WD-1
WOOD-LOOK KNOTWOOD, 6" CLADDINGALUMINUM CLADDING WESTERN RED CEDAR
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216ENLARGED STORAGESHED & TRASHENCLOSURE
A-402
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
0'2' 4'8'
SCALE: 1/4" = 1'-0"
1/4" = 1'-0" Reference: 1 / A-010
1STORAGE SHED AND TRASH ENCLOSURE
Northwest Corner of Parking Lot- Rooms 001 and 002
1/4" = 1'-0"3STORAGE SHED AND TRASH ENCLOSURE SOUTH ELEVATION
Northwest Corner of Parking Lot- Rooms 001 and 002
1/4" = 1'-0" Reference: 1 / A-402
4STORAGE SHED AND TRASH ENCLOSURE SECTION
Northwest Corner of Parking Lot- Rooms 001 and 002
1/4" = 1'-0"2STORAGE SHED RCP
Room 001
KEYNOTES - ENLARGED SITE PLANS
1 CONCRETE WHEEL STOP. PROVIDE AT EACH EV CHARGING/EV READY STALL, ACCESSIBLE STALL ANDSTALL ADJACENT TO AN ACCESSIBLE ROUTE.
2 6" BOLLARD
3 STANDARD STALL - 9' WIDE BY 18' LONG
4 EMERGENCY GENERATOR. SEE ELECTRICAL. PROVIDE DENSE LANDSCAPE SCREENING AT GENERATORENCLOSURE.
5 STANDARD EV CHARGING STALL - 9' WIDE BY 18' LONG
6 STRIPING COLORS: ACCESSIBLE (INCLUDING EV) STALL: BLUE, EV CHARGING STALL: GREEN, STANDARDSTALLS: WHITE. VERIFY STRIPING COLORS WITH AHJ.
7 6" THICK CONCRETE SLAB UNDER TRASH ENCLOSURE. EXTEND SLAB 6' BEYOND ENCLOSURE.
8 TRASH AND RECYCLING DUMPSTERS PROVIDED BY OTHER.
9 GUTTER AND DOWNSPOUT. DOWNSPOUT TO CONNECT TO STORM SEWER.
10 AREA DRAIN. CONNECT TO STORM SEWER.
11 4' HIGH ORNAMENTAL IRON FENCE
12 3' HIGH ORNAMENTAL IRON FENCE ON RETAINING WALL EXTENDING 1' ABOVE GRADE
13 FROST-PROOF WALL HYDRANT IN KEYED BOX.
14 POST HYDRANT
15 EV CHARGING STATION SERVING TWO NON-ACCESSIBLE STALLS, CENTER CHARGING STATIONBETWEEN STALLS. VERIFY CLEARANCES AND DIMENSIONS WITH MANUFACTURER INSTALLATIONINSTRUCTIONS.
16 EV CHARGING STATION SERVING ONE ACCESSIBLE AND ONE NON-ACCESSIBLE SPACE. CHARGINGSTATION MUST BE ON LEVEL WITH ACCESS AISLE. VERIFY CLEARANCES AND DIMENSIONS WITHMANUFACTURER INSTALLATION INSTRUCTIONS.
17 8' WIDE AISLE FOR VAN ACCESSIBLE PARKING STALL. PROVIDE SIGNAGE AS REQUIRED. CHARGINGSTATION TO BE ON LEVEL WITH ACCESS AISLE. PROVIDE BOLLARDS IN FRONT OF CHARGING STATION.DO NOT OBSTRUCT ACCESS AISLE WITH BOLLARDS, WHEEL STOPS OR SIGNAGE.
18 ACCESSIBLE PARKING SPACE - VAN ACCESSIBLE AND EV CHARGING STATION. 8' WIDE BY 20' LONG.PROVIDE SIGNAGE FOR ACCESSIBLE PARKING STALL AS REQUIRED. PROVIDE SIGNAGE INDICATING VANACCESSIBLE STALL. PROVIDE SIGN THAT READS, "ELECTRIC VEHICLE PARKING PREFERRED" BELOWACCESSIBILITY SIGNS. PROVIDE CONCRETE WHEEL STOP. ANY VEHICLE WITH AN ACCESSIBLE PARKINGPERMIT MUST BE ALLOWED TO PARK IN THIS SPACE.
19 SEMI-ENCLOSED SMOKING SHELTER GREATER THAN 25' FROM WINDOWS, DOORS OR AIR INTAKEVENTS. PROVIDE BENCH AT ADA ACCESSIBLE HEIGHT, ASH RECEPTACLE AND TRASH CAN. SCREENWITH LANDSCAPING WHERE POSSIBLE.
20 ACCESSIBLE CURB RAMP TO MEET ALL ACCESSIBILITY REQUIREMENTS. MAXIMUM SLOPE OF RUN 1:12.
21 EMERGENCY SHUT-OFF FOR FIRE PITS AND GAS GRILLS. ENSURE BUTTON IS MOUNTED WITHIN ADAREACH RANGE AND CLEARLY MARKED.
22 TRELLIS ABOVE
23 SURFACE-MOUNTED UTILITY LIGHT
25 ACCESSIBLE ROUTE. MARK WHERE ROUTE CROSSES VEHICULAR TRAFFIC.
29 STAMPED, COLORED CONCRETE APRON AND COURTYARD
30 CANOPY/BALCONY ABOVE
31 40'x100' WEDDING AREA, GREATER THAN 20' FROM BUILDING WALLS. OWNER TO SECURE EVENT PERMITWITH SPOKANE VALLEY FIRE DEPARTMENT PRIOR TO EVENTS.
32 ALL EQUIPMENT (INCLUDING DRYER VENTS) MUST BE SCREENED WITH LANDSCAPING OR OTHERMEANS.
7
88
1010
10
13
9
14
2TYP.
9
8
13
9
14
2TYP.
8
9
2323
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
Revision Schedule
Number Description Date
TV
5
3
D
FGE
1
13
15
A-434A
9
7
10 8
4
K
2
6
H J
D-141
462 SF
OUTDOORKITCHEN
003
TYP
OF-711
TYP
OF-706
TYP
OF-702
TYP
OF-708
TYP
OF-700
TYP
OF-705
TYP
OF-708
TYP
OF-702
A-4041
A-406
3
TYP
OF-701
TYP
OF-701
TYP
OF-706
TYP
OF-703
OF-707
TYP
OF-702
TYP
OF-702
TYP
OF-700
TYP
OF-705
2
A-301
204 SF
POOL MEP
103
D-121
SC-01
SITE LEGEND
DUPLEX OUTLET - GFCI
DUPLEX OUTLET - WEATHERPROOF/GFCI
COMBINED SMOKE/CARBON MONOXIDE DETECTOR
OUTDOOR KITCHEN PENDANT (OF-704)
FREEZEPROOF WALL HYDRANT
POLE HYDRANT
6" ROUND BOLLARD
WP
S/CO
ACT ACOUSTIC CEILING TILEASALUMINUM STOREFRONTCGCORNER GUARDCONC CONCRETE, UNFINISHEDCPCARPETCPTCARPET TILECSCONCRETE, FINISHEDGWBGYPSUM WALL BOARDFCFIBER CEMENTFRPFIBERGLASS-REINFORCEDPLASTICMR GWB MOISTURE-RESISTANT GYPSUM WALL BOARDPLPLASTIC LAMINATEPTPAINT/POWDER COATQTQUARRY TILERBRUBBER BASERESRESILIENT TILE FLOORSCSTAMPED CONCRETESFSPECIALTY FINISH (KNOCK DOWN)SS ENGINEERED SOLID SURFACESTSTONESTLSTAINLESS STEELSTRUC STRUCTURE ABOVEVCTVINYL COMPOSITE TILEWCVINYL WALL COVERINGWDWOOD-LOOK ALUMINUM SLATS AND BATTENSWPSCREEN WALL
NOTE: REFER TO FF&E PACKAGE AND SPECIFICATION BOOK FOR FURNITURE AND FINISH SPECIFICATIONS
FINISH LEGEND
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216ENLARGEDCOURTYARD PLANS
A-403
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
0'2' 4'8'
SCALE: 1/4" = 1'-0"
1/4" = 1'-0" Reference: 1 / A-010
1COURTYARD PLAN
North Side of Lobby
KEYNOTES - ENLARGED SITE PLANS
1 CONCRETE WHEEL STOP. PROVIDE AT EACH EV CHARGING/EV READY STALL, ACCESSIBLE STALL ANDSTALL ADJACENT TO AN ACCESSIBLE ROUTE.
2 6" BOLLARD
3 STANDARD STALL - 9' WIDE BY 18' LONG
4 EMERGENCY GENERATOR. SEE ELECTRICAL. PROVIDE DENSE LANDSCAPE SCREENING AT GENERATORENCLOSURE.
5 STANDARD EV CHARGING STALL - 9' WIDE BY 18' LONG
6 STRIPING COLORS: ACCESSIBLE (INCLUDING EV) STALL: BLUE, EV CHARGING STALL: GREEN, STANDARDSTALLS: WHITE. VERIFY STRIPING COLORS WITH AHJ.
7 6" THICK CONCRETE SLAB UNDER TRASH ENCLOSURE. EXTEND SLAB 6' BEYOND ENCLOSURE.
8 TRASH AND RECYCLING DUMPSTERS PROVIDED BY OTHER.
9 GUTTER AND DOWNSPOUT. DOWNSPOUT TO CONNECT TO STORM SEWER.
10 AREA DRAIN. CONNECT TO STORM SEWER.
11 4' HIGH ORNAMENTAL IRON FENCE
12 3' HIGH ORNAMENTAL IRON FENCE ON RETAINING WALL EXTENDING 1' ABOVE GRADE
13 FROST-PROOF WALL HYDRANT IN KEYED BOX.
14 POST HYDRANT
15 EV CHARGING STATION SERVING TWO NON-ACCESSIBLE STALLS, CENTER CHARGING STATIONBETWEEN STALLS. VERIFY CLEARANCES AND DIMENSIONS WITH MANUFACTURER INSTALLATIONINSTRUCTIONS.
16 EV CHARGING STATION SERVING ONE ACCESSIBLE AND ONE NON-ACCESSIBLE SPACE. CHARGINGSTATION MUST BE ON LEVEL WITH ACCESS AISLE. VERIFY CLEARANCES AND DIMENSIONS WITHMANUFACTURER INSTALLATION INSTRUCTIONS.
17 8' WIDE AISLE FOR VAN ACCESSIBLE PARKING STALL. PROVIDE SIGNAGE AS REQUIRED. CHARGINGSTATION TO BE ON LEVEL WITH ACCESS AISLE. PROVIDE BOLLARDS IN FRONT OF CHARGING STATION.DO NOT OBSTRUCT ACCESS AISLE WITH BOLLARDS, WHEEL STOPS OR SIGNAGE.
18 ACCESSIBLE PARKING SPACE - VAN ACCESSIBLE AND EV CHARGING STATION. 8' WIDE BY 20' LONG.PROVIDE SIGNAGE FOR ACCESSIBLE PARKING STALL AS REQUIRED. PROVIDE SIGNAGE INDICATING VANACCESSIBLE STALL. PROVIDE SIGN THAT READS, "ELECTRIC VEHICLE PARKING PREFERRED" BELOWACCESSIBILITY SIGNS. PROVIDE CONCRETE WHEEL STOP. ANY VEHICLE WITH AN ACCESSIBLE PARKINGPERMIT MUST BE ALLOWED TO PARK IN THIS SPACE.
19 SEMI-ENCLOSED SMOKING SHELTER GREATER THAN 25' FROM WINDOWS, DOORS OR AIR INTAKEVENTS. PROVIDE BENCH AT ADA ACCESSIBLE HEIGHT, ASH RECEPTACLE AND TRASH CAN. SCREENWITH LANDSCAPING WHERE POSSIBLE.
20 ACCESSIBLE CURB RAMP TO MEET ALL ACCESSIBILITY REQUIREMENTS. MAXIMUM SLOPE OF RUN 1:12.
21 EMERGENCY SHUT-OFF FOR FIRE PITS AND GAS GRILLS. ENSURE BUTTON IS MOUNTED WITHIN ADAREACH RANGE AND CLEARLY MARKED.
22 TRELLIS ABOVE
23 SURFACE-MOUNTED UTILITY LIGHT
25 ACCESSIBLE ROUTE. MARK WHERE ROUTE CROSSES VEHICULAR TRAFFIC.
29 STAMPED, COLORED CONCRETE APRON AND COURTYARD
30 CANOPY/BALCONY ABOVE
31 40'x100' WEDDING AREA, GREATER THAN 20' FROM BUILDING WALLS. OWNER TO SECURE EVENT PERMITWITH SPOKANE VALLEY FIRE DEPARTMENT PRIOR TO EVENTS.
32 ALL EQUIPMENT (INCLUDING DRYER VENTS) MUST BE SCREENED WITH LANDSCAPING OR OTHERMEANS.
8. CATCH BASINS ARE TO BE PLACED SO AS NOT TO INTERFERE WITH DESIGNATED ACCESSIBLE ROUTES.
7. 10% OF NON-PAVED, NON-COVERED AREA OF PROJECT SITE TO BE LANDSCAPED.
6. INSTALL ACCENT PLANTINGS OF ANNUALS AND PERENNIALS AT MAIN ENTRANCE, BUILDING ENTRY, AND SIGNAGEAREAS, AND BACKYARD.
5. SOD ALL AREAS NOT WITHIN PLANTING BEDS.
4. IRRIGATE ALL LANDSCAPED AREAS WITH AUTOMATIC UNDERGROUND SPRINKLER SYSTEM.
3. BUILDING UPLIGHTING SHALL NOT BE OBSTRUCTED BY LANDSCAPE PLANTINGS.
2. REFER TO HILTON SIGNAGE STANDARDS, BRAND STANDARDS AND HILTON marKIT FOR ADDITIONAL INFORMATIONAND PRECISE SIGNAGE REQUIREMENTS. ELECTRICAL FOR BUILDING SIGNAGE AND MONUMENT SIGNAGE SHALLBE PROVIDED AND CONNECTED BY THE CONTRACTOR.
1. COORDINATE LIGHTING LOCATIONS WITH LANDSCAPE PLANTINGS
GENERAL NOTES- SITE
30
31
32
30
3030
25
25
29
29
13
13
13
21
21
21
22
22
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
Revision Schedule
Number Description Date
A-40527
1
A-405
TYP
OF-702
OF-708
TYP
OF-703
K-96
OF-708
TYP
OF-702
XS7
XS7
XS7
K-96
22' - 0"
1
A-406
A-4055
A-405
6
4' - 0"4' - 2 1/2"2' - 6"10' - 0"3' - 4 1/4"3' - 0"5' - 6"3' - 0"3' - 4 1/4"0' - 6 1/4"3' - 0"2' - 1"
3' - 3"0' - 7 1/2"11' - 0"11' - 0"6' - 5 1/4"A-4054A-405
3
FRP-01
SS-10
SS-10
K-97
K-97
XS6
SC-01
1
A-405
0' - 9"22' - 0"0' - 9"0' - 9"22' - 0"0' - 9"23' - 6"23' - 6"9' - 1 1/2"3' - 0"3' - 0"TYP
OF-704
PC-04
PC-04PC-04WD-1
LINEAR LIGHT FIXTURE, SEE ELECTRICAL
SS-10
SS-10
SS-10
SITE LEGEND
DUPLEX OUTLET - GFCI
DUPLEX OUTLET - WEATHERPROOF/GFCI
COMBINED SMOKE/CARBON MONOXIDE DETECTOR
OUTDOOR KITCHEN PENDANT (OF-704)
FREEZEPROOF WALL HYDRANT
POLE HYDRANT
6" ROUND BOLLARD
WP
S/CO
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216ENLARGED OUTDOORKITCHEN PLANS
A-404
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
0'1' 2'4'
SCALE: 1/2" = 1'-0"
1/2" = 1'-0" Reference: 1 / A-403
1OUTDOOR KITCHEN PLAN
Room 003 In Courtyard
1/2" = 1'-0"3 OUTDOOR KITCHEN RCP
Room 003 In Courtyard
1/2" = 1'-0"2COUNTER CAP PLAN
Room 003 In Courtyard
KEYNOTES - ENLARGED SITE PLANS
1 CONCRETE WHEEL STOP. PROVIDE AT EACH EV CHARGING/EV READY STALL, ACCESSIBLE STALL ANDSTALL ADJACENT TO AN ACCESSIBLE ROUTE.
2 6" BOLLARD
3 STANDARD STALL - 9' WIDE BY 18' LONG
4 EMERGENCY GENERATOR. SEE ELECTRICAL. PROVIDE DENSE LANDSCAPE SCREENING AT GENERATORENCLOSURE.
5 STANDARD EV CHARGING STALL - 9' WIDE BY 18' LONG
6 STRIPING COLORS: ACCESSIBLE (INCLUDING EV) STALL: BLUE, EV CHARGING STALL: GREEN, STANDARDSTALLS: WHITE. VERIFY STRIPING COLORS WITH AHJ.
7 6" THICK CONCRETE SLAB UNDER TRASH ENCLOSURE. EXTEND SLAB 6' BEYOND ENCLOSURE.
8 TRASH AND RECYCLING DUMPSTERS PROVIDED BY OTHER.
9 GUTTER AND DOWNSPOUT. DOWNSPOUT TO CONNECT TO STORM SEWER.
10 AREA DRAIN. CONNECT TO STORM SEWER.
11 4' HIGH ORNAMENTAL IRON FENCE
12 3' HIGH ORNAMENTAL IRON FENCE ON RETAINING WALL EXTENDING 1' ABOVE GRADE
13 FROST-PROOF WALL HYDRANT IN KEYED BOX.
14 POST HYDRANT
15 EV CHARGING STATION SERVING TWO NON-ACCESSIBLE STALLS, CENTER CHARGING STATIONBETWEEN STALLS. VERIFY CLEARANCES AND DIMENSIONS WITH MANUFACTURER INSTALLATIONINSTRUCTIONS.
16 EV CHARGING STATION SERVING ONE ACCESSIBLE AND ONE NON-ACCESSIBLE SPACE. CHARGINGSTATION MUST BE ON LEVEL WITH ACCESS AISLE. VERIFY CLEARANCES AND DIMENSIONS WITHMANUFACTURER INSTALLATION INSTRUCTIONS.
17 8' WIDE AISLE FOR VAN ACCESSIBLE PARKING STALL. PROVIDE SIGNAGE AS REQUIRED. CHARGINGSTATION TO BE ON LEVEL WITH ACCESS AISLE. PROVIDE BOLLARDS IN FRONT OF CHARGING STATION.DO NOT OBSTRUCT ACCESS AISLE WITH BOLLARDS, WHEEL STOPS OR SIGNAGE.
18 ACCESSIBLE PARKING SPACE - VAN ACCESSIBLE AND EV CHARGING STATION. 8' WIDE BY 20' LONG.PROVIDE SIGNAGE FOR ACCESSIBLE PARKING STALL AS REQUIRED. PROVIDE SIGNAGE INDICATING VANACCESSIBLE STALL. PROVIDE SIGN THAT READS, "ELECTRIC VEHICLE PARKING PREFERRED" BELOWACCESSIBILITY SIGNS. PROVIDE CONCRETE WHEEL STOP. ANY VEHICLE WITH AN ACCESSIBLE PARKINGPERMIT MUST BE ALLOWED TO PARK IN THIS SPACE.
19 SEMI-ENCLOSED SMOKING SHELTER GREATER THAN 25' FROM WINDOWS, DOORS OR AIR INTAKEVENTS. PROVIDE BENCH AT ADA ACCESSIBLE HEIGHT, ASH RECEPTACLE AND TRASH CAN. SCREENWITH LANDSCAPING WHERE POSSIBLE.
20 ACCESSIBLE CURB RAMP TO MEET ALL ACCESSIBILITY REQUIREMENTS. MAXIMUM SLOPE OF RUN 1:12.
21 EMERGENCY SHUT-OFF FOR FIRE PITS AND GAS GRILLS. ENSURE BUTTON IS MOUNTED WITHIN ADAREACH RANGE AND CLEARLY MARKED.
22 TRELLIS ABOVE
23 SURFACE-MOUNTED UTILITY LIGHT
25 ACCESSIBLE ROUTE. MARK WHERE ROUTE CROSSES VEHICULAR TRAFFIC.
29 STAMPED, COLORED CONCRETE APRON AND COURTYARD
30 CANOPY/BALCONY ABOVE
31 40'x100' WEDDING AREA, GREATER THAN 20' FROM BUILDING WALLS. OWNER TO SECURE EVENT PERMITWITH SPOKANE VALLEY FIRE DEPARTMENT PRIOR TO EVENTS.
32 ALL EQUIPMENT (INCLUDING DRYER VENTS) MUST BE SCREENED WITH LANDSCAPING OR OTHERMEANS.
8. CATCH BASINS ARE TO BE PLACED SO AS NOT TO INTERFERE WITH DESIGNATED ACCESSIBLE ROUTES.
7. 10% OF NON-PAVED, NON-COVERED AREA OF PROJECT SITE TO BE LANDSCAPED.
6. INSTALL ACCENT PLANTINGS OF ANNUALS AND PERENNIALS AT MAIN ENTRANCE, BUILDING ENTRY, AND SIGNAGEAREAS, AND BACKYARD.
5. SOD ALL AREAS NOT WITHIN PLANTING BEDS.
4. IRRIGATE ALL LANDSCAPED AREAS WITH AUTOMATIC UNDERGROUND SPRINKLER SYSTEM.
3. BUILDING UPLIGHTING SHALL NOT BE OBSTRUCTED BY LANDSCAPE PLANTINGS.
2. REFER TO HILTON SIGNAGE STANDARDS, BRAND STANDARDS AND HILTON marKIT FOR ADDITIONAL INFORMATIONAND PRECISE SIGNAGE REQUIREMENTS. ELECTRICAL FOR BUILDING SIGNAGE AND MONUMENT SIGNAGE SHALLBE PROVIDED AND CONNECTED BY THE CONTRACTOR.
1. COORDINATE LIGHTING LOCATIONS WITH LANDSCAPE PLANTINGS
GENERAL NOTES- SITE
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
Revision Schedule
Number Description Date
4' - 9"2' - 10"A-4062
A-4061
OF-704
A-4058
0' - 3"9' - 6"0' - 3"2' - 10"CT-14
FRP-01FRP-01
CT-14
2' - 10"FRP-01
1' - 11 1/4"0' - 4 1/4"3' - 0"3' - 0"2' - 9"2' - 9"3' - 0"3' - 0"3' - 0"7' - 1 3/4"WD-1
WD-1
PC-04
SS-10
XS-F
SS-10
SS-10SS-10
K-96
STL STL STL STL STL
SS-10
STL STL
SS-10
SS-10
ALUMINUM BATTEN TRELLIS
STRUCTURAL COLUMN, TYP.
WD-1
WD-1
PC-04
SS-10
XS-F
PC-04
OF-704
FRP-01
SS-10
XS-F
SS-10
STRUCTURAL COLUMN, TYP.
STRUCTURAL COLUMN, TYP.
TYP
OF-704
SS-10SS-10SS-10
K-96 K-96
WD-1
PC-04
WD-1
STLSTL
ACT ACOUSTIC CEILING TILEASALUMINUM STOREFRONTCGCORNER GUARDCONC CONCRETE, UNFINISHEDCPCARPETCPTCARPET TILECSCONCRETE, FINISHEDGWBGYPSUM WALL BOARDFCFIBER CEMENTFRPFIBERGLASS-REINFORCEDPLASTICMR GWB MOISTURE-RESISTANT GYPSUM WALL BOARDPLPLASTIC LAMINATEPTPAINT/POWDER COATQTQUARRY TILERBRUBBER BASERESRESILIENT TILE FLOORSCSTAMPED CONCRETESFSPECIALTY FINISH (KNOCK DOWN)SS ENGINEERED SOLID SURFACESTSTONESTLSTAINLESS STEELSTRUC STRUCTURE ABOVEVCTVINYL COMPOSITE TILEWCVINYL WALL COVERINGWDWOOD-LOOK ALUMINUM SLATS AND BATTENSWPSCREEN WALL
NOTE: REFER TO FF&E PACKAGE AND SPECIFICATION BOOK FOR FURNITURE AND FINISH SPECIFICATIONS
FINISH LEGEND
2"X6" ALUMINUM BATTENSEE KNOTWOOD INSTALLATION INSTRUCTIONS
HOLLOW STEEL STRUCTURAL MEMBER. SEE STRUCTURAL.
COLUMN COVER TO MATCH WOOD-LOOK FINISH OF BATTENS
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216ENLARGED OUTDOORKITCHEN ELEVATIONS,SECTIONS & DETAILS
A-405
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
0'2' 4'8'
SCALE: 1/4" = 1'-0"
1/2" = 1'-0" Reference: 1 / A-404
3OUTDOOR KITCHEN NORTH ELEVATION
Room 003 In Courtyard
1/2" = 1'-0" Reference: 1 / A-404
4OUTDOOR KITCHEN WEST ELEVATION
Room 003 In Courtyard
1/2" = 1'-0" Reference: 1 / A-404
1OUTDOOR KITCHEN SECTION
Room 003 In Courtyard
1/2" = 1'-0" Reference: 1 / A-404
7OUTDOOR ISLAND EAST ELEVATION
Room 003 In Courtyard
1/2" = 1'-0" Reference: 1 / A-404
5OUTDOOR ISLAND WEST ELEVATION
Room 003 In Courtyard
1/2" = 1'-0" Reference: 1 / A-404
6OUTDOOR ISLAND NORTH ELEVATION
Room 003 In Courtyard
1/2" = 1'-0" Reference: 1 / A-404
2OUTDOOR KITCHEN GRILL COUNTER ELEVATION
Room 003 In Courtyard
1 1/2" = 1'-0" Reference: 1 / A-405
8 TRELLIS DETAIL
0'4" 8"1' 4"
SCALE: 1 1/2" = 1'-0"
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
Revision Schedule
Number Description Date
6' - 10"1' - 6"0' - 6 1/2"5' - 9"0' - 6 1/2"0' - 6 1/2"1' - 9"0' - 6 1/2"
2' - 10"
12"X60"LINEAR FIRE PIT
1' - 6"6' - 3"0' - 7"0' - 4"0' - 8"6' - 10"
5' - 9"
1/4" TEMPERED GLASS W/ POLISHED EDGES
BOARD FORMED CONCRETE
LOCATED EMERGENCY SHUT-OFF BUTTON ON END OF FIRE PIT
1' - 3"0' - 4" 0' - 8"
0' - 7"1' - 8"0' - 7"
2' - 10"
1' - 9"
3' - 6"
1/4" TEMPERED GLASSW/ POLISHED EDGES
BOARD FORMED CONCRETE
0' - 4"
0' - 11"1' - 3"0' - 4"0' - 4"1' - 11"0' - 11 1/4"
1' - 9"
7/8"1"1' - 7"1/4" TEMPERED GLASS IN U-CHANNEL SUPPORT
COLOR D, REF-???
LINEAR LED LIGHTING
BOARD FORMED CONCRETE
1' - 8"2' - 10"0' - 3 1/2"4' - 0"
0' - 2"
℄0' - 3"℄2' - 0"2' - 7"0' - 3"2' - 10"1' - 0"
1' - 6"
CERAMIC TILE, CT-14
MARINE GRADE PLYWOOD, TYP
MITERED CORNER
2 CM ENGINEERED STONE, SS-10
PURSE HOOK
LIGHTING AS SPECIFIED
GFCI GUEST CONVENIENCE OUTLET
2 CM ENGINEERED STONE, SS-10
STAINLESS STEEL
0' - 4"0' - 3"MITERED CORNER
2 CM ENGINEERED STONE
STAINLESS STEEL
THIN BRICK VENEER COLOR C, REF ???
2 CM SOLID SURFACE
2 CM ENGINEERED STONE, SS-10
MARINE GRADE PLYWOOD,TYP4' - 2 1/2"0' - 6 1/2"4' - 9"1' - 0"
0' - 1"0' - 4"
1" = 1'-0" Reference: 1 / A-403
3 FIREPIT PLAN
1" = 1'-0"4 FIRE PIT SIDE ELEVATION
1" = 1'-0" Reference: 3 / A-406
5 FIRE PIT END ELEVATION
1" = 1'-0" Reference: 3 / A-406
6 FIRE PIT SECTION 1" = 1'-0" Reference: 1 / A-404
1OUTDOOR KITCHEN ISLAND SECTION
1" = 1'-0" Reference: 1 / A-404
2OUTDOOR KITCHEN COUNTER SECTION
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216ENLARGED OUTDOORKITCHEN DETAILS
A-406
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
0'2' 4'8'
SCALE: 1/4" = 1'-0"
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
Revision Schedule
Number Description Date
A-202
1
FGE
11
9
K
3
A-505
10
H J
2
A-301
1
A-505
OP-704OP-704
2
29
5
20
30
2020
393927' - 1 1/2"17' - 7"44' - 0"
30' - 0"12' - 0"24' - 11 1/4"39' - 3"7' - 10"4' - 0"21
22
A-432A
4
5
7
8
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216ENLARGED PORTECOCHERE PLAN
A-407
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
0'2' 4'8'
SCALE: 1/4" = 1'-0"
1/4" = 1'-0" Reference: 1 / A-010
1PORTE COCHERE PLAN
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
Revision Schedule
Number Description Date
MMAATV
SD
TV
A-434A10
A-411B
1
2
3
4
A-411B
6
5
A-423
1
D-G03
7' - 9 3/4"6' - 9 3/4"2' - 1"P1.1
P1.2
GR-307
GR-201
GR-907
GR-307
GR-100
GR-313
GR-ES
GR-400GR-906GR-911
GR-310
GR-102
GR-325
GR-908
GR-201
GR-501
D-G02
GR-400
GR-200
GR-506
GR-508
D-G01
6' - 5 3/4"10' - 6 1/4"4' - 0"
14' - 3 3/4"
P3.1
XE1/2
3' - 2 1/4"4' - 7 3/4"
GR-319
AP-01
GR-500
GR-901
GR-902
6' - 0 1/2"
CL-A8' - 0"
GR-400 GR-400GR-4102' - 4"2' - 4"3' - 4"
1
7' - 2"5' - 3"1' - 0"A-423
2
1
CL-B8' - 0"
CL-B27' - 6"
CL-B27' - 6"
PLAN ELEV
DUPLEX OUTLET
QUADPLEX OUTLET
GFCI OUTLET
CAT6, RJ45 INTERNET OUTLET
TELEPHONE OUTLET
WALL MOUNTED WIRELESS THERMOSTAT
POWER OUTLET WITH USB PORTS
CATV OUTLET
ELECTRICAL SWITCH
FLOOR OUTLET
POWER AND SIGNAL LEGEND:
POWER SUPPLY
CEILING FIXTURE LEGEND:
6" RECESSED CAN DOWNLIGHT
DECORATIVE FLUSH MOUNT LIGHT
PENDENT TYPE SPRINKLERS
SMOKE DETECTOR
EXHAUST FAN / GRILLE
LINEAR SURFACE MOUNTED CONTINUOUS LED SYSTEM W/ FIXED MOUNTING CLIPS & FROSTED LENS / 3 WATTS PER FOOT, MLV/FWD
ELECTRICAL OUTLET HEIGHTS (U.N.O)
TYPICAL OUTLET - 15" A.F.F
TYPICAL ACCESSIBLE WALL OUTLET - 18" A.F.F
BATHROOM VANITY OUTLET - 42" A.F.F
TYP. KITCHEN OUTLET - 42" A.F.F
ADA KITCHEN OUTLET - 46" A.F.F
ADA BATHROOM VANITY OUTLET - 44" A.F.F
ELECTRICAL SWITCH HEIGHTS (U.N.O)
SWITCH - 44" A.F.F
THERMOSTAT REMOTE - 48" A.F.F MAX TO TOP OF SWITCH
JUNCTION BOX
DOOR BELL HARDWIRED TO DOORBELL LIGHT - MOUNT @ 46" A.F.F TO CENTER OF BUTTON (FOR COMMUNICATIONS FEATURES ROOMS ONLY)
SD
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216UNIT PLANS -EFFICIENCY STUDIO
A-411
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
0'1' 2'4'
SCALE: 1/2" = 1'-0"
1/2" = 1'-0" Reference: 1 / A-102
1EFFICIENCY STUDIO CONSTRUCTION PLAN
Units x05, 307, 407, 507, x08, x27-x29, x31, x33-x34
1/2" = 1'-0"2EFFICIENCY STUDIO REFLECTED CEILING PLAN
Units x05, 307, 407, 507, x08, x27-x29, x31, x33-x34
22
2
2
2
2
5
KEYNOTES - UNIT PLANS
1 ALIGN
2 GENERAL CONTRACTOR TO COORDINATE W/ FURNITUREFABRICATOR WHERE NECESSARY TO PROVIDE PROPERBLOCKING IN WALL FOR ITEM KEYNOTED
3 NO FINISHES UNDER THE SHOWER PAN / TUB
4 NO FINISHES UNDER MILLWORK CABINETRY
5 TV AND MOUNT NOT TO PROJECT MORE THAN 4" FROMWALL
6 MOTORIZED BLINDS. PROVIDE JUNCTION BOX BEHINDVALENCE FOR POWER CONNECTION AND PERMANENTLYINSTALLED SWITCH ON WALL TO CONTROL BLINDS.
7 SWITCH CONTROLLING UNDER CABINET LIGHTING ATKITCHEN TO BE GANGED WITH LIGHTING AT ENTRY
8 SWITCH CONTROLLING GARBAGE DISPOSAL-REFER TOHADG FOR ACCESSIBLE ROOM REQ'S.
9 DEDICATED CIRCUIT FOR GARBAGE DISPOSAL
10 MASTER SWITCH
11 DEDICATED CIRCUIT FOR INDUCTION COOKTOP
12 DEDICATED CIRCUIT FOR DISHWASHER
13 DEDICATED CIRCUIT FOR REFRIGERATOR
14 ELECTRIC VANITY MIRROR - HARDWIRE FIXTURE TO WALL-CONTRACTOR TO VERIFY JBOX TYPE TO ENSURE PROPERINSTALLATION AND BACKING FOR ITEM KEYNOTED
15 DOORBELL AND DOORBELL ON/OFF SWITCH(COMMUNICATION FEATURES ROOMS ONLY)SIGNAGE ASREQ'D.
16 PLACE TV OUTLETS AND CONNECTIONS ON WALL OUTSIDEAREA OF BRACKET AND CONCEALED FROM VIEW BY TV
17 DEDICATED CIRCUIT FOR WASHER/DRYER. DIRECT VENTTO EXTERIOR
FURNISHING SCHEDULE
GUESTROOM FURNISHINGS
GR-100 CHAIR - LOUNGE CHAIR WITH OTTOMAN
GR-102 CHAIR - COUNTER HEIGHT DESK CHAIR
GR-200 SCONCE - PIN-UP
GR-201 SCONCE - NIGHTSTAND
GR-202 LAMP - DESK
GR-307 NIGHTSTAND - SMALL
GR-310 DESK - EFFICIENCY
GR-313 TABLE - ROUND SIDE TABLE
GR-319 CLOSET - EFFICIENCY SUITE
GR-325 VANITY - EFFICIENCY SUITE
GR-326 VANITY - STUDIO AND 1-BEDROOM SUITES
GR-400 STATIC DRAPARY PANELS
GR-403 ROLLER SHADE - GUESTROOMS (MANUAL,SHEER/BLACK-OUT, 8' W)
GR-410 VALENCE FOR 5' WINDOW
GR-500 ART
GR-501 ART
GR-505 WALL HOOK
GR-506 MIRROR - GUESTROOM FULL LENGTH
GR-508 MIRROR - GUESTROOM VANITY
GR-802 KITCHENETTE - EFFICIENCY SUITE
GR-900 GUESTROOM REFRIGERATOR
GR-901 GUESTROOM DISHWASHER
GR-902 GUESTROOM COOKTOP - 2 BURNER
GR-904 GARBAGE DISPOSAL 1/3HP
GR-905 MICROWAVE- WITH RECIRCULATING HOOD
GR-906GR-911 TELEVISION & TELEVISION MOUNT
GR-907 CLOCK/RADIO
GR-908 TELEPHONE - GUESTROOM
GR-ES BED - EFFICIENCY (GR-300, 303, 600)
GR-KS BED - KING (GR-301, 303, 600)
PLUMBING/MECHANICAL FIXTURES
PF-01 TOILET - GUESTROOM
PF-03 SHOWER BASE - 60" X 36" WITH LINEARDRAIN
PF-07 LAVATORY - UNDERMOUNT, 20" X 14"
PF-11 SHOWER HEAD - 2 IN 1
PF-13 SHOWER/TUB VALVE & CONTROL
PF-15 FAUCET - LAVATORY
PF-40 SINK - KITCHENETTE
PF-41 FAUCET - KITCHENETTE
TOILET ACCESSORIES
HD-01 DUAL TOILET PAPER HOLDER
HD-04 WALL-MOUNTED ROBE HOOK
HD-05.2 SLIDING SHOWER DOOR
HD-08 18" GRAB BAR
HD-16 BULK AMENITY DISPENSER ATSHOWERS/TUBS
HD-18 FOOT LEDGE FOR SHOWER
HD-18.1 SOAP SHELF
HD-21 BULK AMENITY DISPENSER AT LAVATORIES
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
Revision Schedule
Number Description Date
TV
TV
CPT-10
SF-01
WC-01
WC-01
WC-01
WC-01WC-01
WC-01
CPT-01
CT-01
RES-01
CPT-01
1
A-510
Sim
2
A-510
Sim
7
A-510
Sim
9
A-510
Sim
3
A-710
A-434A10
A-411B
1
2
3
4
A-411B
6
5
A-423
1
PLAN ELEV
DUPLEX OUTLET
QUADPLEX OUTLET
GFCI OUTLET
CAT6, RJ45 INTERNET OUTLET
TELEPHONE OUTLET
WALL MOUNTED WIRELESS THERMOSTAT
POWER OUTLET WITH USB PORTS
CATV OUTLET
ELECTRICAL SWITCH
FLOOR OUTLET
POWER AND SIGNAL LEGEND:
POWER SUPPLY
CEILING FIXTURE LEGEND:
6" RECESSED CAN DOWNLIGHT
DECORATIVE FLUSH MOUNT LIGHT
PENDENT TYPE SPRINKLERS
SMOKE DETECTOR
EXHAUST FAN / GRILLE
LINEAR SURFACE MOUNTED CONTINUOUS LED SYSTEM W/ FIXED MOUNTING CLIPS & FROSTED LENS / 3 WATTS PER FOOT, MLV/FWD
ELECTRICAL OUTLET HEIGHTS (U.N.O)
TYPICAL OUTLET - 15" A.F.F
TYPICAL ACCESSIBLE WALL OUTLET - 18" A.F.F
BATHROOM VANITY OUTLET - 42" A.F.F
TYP. KITCHEN OUTLET - 42" A.F.F
ADA KITCHEN OUTLET - 46" A.F.F
ADA BATHROOM VANITY OUTLET - 44" A.F.F
ELECTRICAL SWITCH HEIGHTS (U.N.O)
SWITCH - 44" A.F.F
THERMOSTAT REMOTE - 48" A.F.F MAX TO TOP OF SWITCH
JUNCTION BOX
DOOR BELL HARDWIRED TO DOORBELL LIGHT - MOUNT @ 46" A.F.F TO CENTER OF BUTTON (FOR COMMUNICATIONS FEATURES ROOMS ONLY)
SD
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216UNIT PLANS -EFFICIENCY STUDIO -ELEC, DATA & FLOORFINISH PLAN
A-411A
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
1/2" = 1'-0"2EFFICIENCY STUDIO FLOOR & WALL FINISH PLAN
Units x05, 307, 407, 507, x08, x27-x29, x31, x33-x34
1/2" = 1'-0"1EFFICIENCY STUDIO ELECTRICAL & DATA PLAN
Units x05, 307, 407, 507, x08, x27-x29, x31, x33-x34
0'1' 2'4'
SCALE: 1/2" = 1'-0"
15
12
8
7
9
10
11
13
14
3
KEYNOTES - UNIT PLANS
1 ALIGN
2 GENERAL CONTRACTOR TO COORDINATE W/ FURNITUREFABRICATOR WHERE NECESSARY TO PROVIDE PROPERBLOCKING IN WALL FOR ITEM KEYNOTED
3 NO FINISHES UNDER THE SHOWER PAN / TUB
4 NO FINISHES UNDER MILLWORK CABINETRY
5 TV AND MOUNT NOT TO PROJECT MORE THAN 4" FROMWALL
6 MOTORIZED BLINDS. PROVIDE JUNCTION BOX BEHINDVALENCE FOR POWER CONNECTION AND PERMANENTLYINSTALLED SWITCH ON WALL TO CONTROL BLINDS.
7 SWITCH CONTROLLING UNDER CABINET LIGHTING ATKITCHEN TO BE GANGED WITH LIGHTING AT ENTRY
8 SWITCH CONTROLLING GARBAGE DISPOSAL-REFER TOHADG FOR ACCESSIBLE ROOM REQ'S.
9 DEDICATED CIRCUIT FOR GARBAGE DISPOSAL
10 MASTER SWITCH
11 DEDICATED CIRCUIT FOR INDUCTION COOKTOP
12 DEDICATED CIRCUIT FOR DISHWASHER
13 DEDICATED CIRCUIT FOR REFRIGERATOR
14 ELECTRIC VANITY MIRROR - HARDWIRE FIXTURE TO WALL-CONTRACTOR TO VERIFY JBOX TYPE TO ENSURE PROPERINSTALLATION AND BACKING FOR ITEM KEYNOTED
15 DOORBELL AND DOORBELL ON/OFF SWITCH(COMMUNICATION FEATURES ROOMS ONLY)SIGNAGE ASREQ'D.
16 PLACE TV OUTLETS AND CONNECTIONS ON WALL OUTSIDEAREA OF BRACKET AND CONCEALED FROM VIEW BY TV
17 DEDICATED CIRCUIT FOR WASHER/DRYER. DIRECT VENTTO EXTERIOR
FURNISHING SCHEDULE
GUESTROOM FURNISHINGS
GR-100 CHAIR - LOUNGE CHAIR WITH OTTOMAN
GR-102 CHAIR - COUNTER HEIGHT DESK CHAIR
GR-200 SCONCE - PIN-UP
GR-201 SCONCE - NIGHTSTAND
GR-202 LAMP - DESK
GR-307 NIGHTSTAND - SMALL
GR-310 DESK - EFFICIENCY
GR-313 TABLE - ROUND SIDE TABLE
GR-319 CLOSET - EFFICIENCY SUITE
GR-325 VANITY - EFFICIENCY SUITE
GR-400 STATIC DRAPARY PANELS
GR-500 ART
GR-501 ART
GR-506 MIRROR - GUESTROOM FULL LENGTH
GR-508 MIRROR - GUESTROOM VANITY
GR-900 GUESTROOM REFRIGERATOR
GR-901 GUESTROOM DISHWASHER
GR-902 GUESTROOM COOKTOP - 2 BURNER
GR-904 GARBAGE DISPOSAL 1/3HP
GR-906GR-911 TELEVISION & TELEVISION MOUNT
GR-907 CLOCK/RADIO
GR-908 TELEPHONE - GUESTROOM
GR-ES BED - EFFICIENCY (GR-300, 303, 600)
PLUMBING/MECHANICAL FIXTURES
PF-01 TOILET - GUESTROOM
PF-03 SHOWER BASE - 60" X 36" WITH LINEARDRAIN
PF-07 LAVATORY - UNDERMOUNT, 20" X 14"
PF-11 SHOWER HEAD - 2 IN 1
PF-13 SHOWER/TUB VALVE & CONTROL
PF-15 FAUCET - LAVATORY
PF-40 SINK - KITCHENETTE
PF-41 FAUCET - KITCHENETTE
TOILET ACCESSORIES
HD-01 DUAL TOILET PAPER HOLDER
HD-05.2 SLIDING SHOWER DOOR
HD-08 18" GRAB BAR
HD-16 BULK AMENITY DISPENSER ATSHOWERS/TUBS
HD-18 FOOT LEDGE FOR SHOWER
HD-18.1 SOAP SHELF
HD-21 BULK AMENITY DISPENSER AT LAVATORIES
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
Revision Schedule
Number Description Date
TV
WC-01
RB-01
WD-01
WD-01
SS-01
D-G01
PT-11PL-01
0' - 8"
2' - 10 3/4"
WC-01WC-01
1' - 10"
GR-505
0' - 6"1' - 5"
RB-01
WC-01
5' - 1 1/2"5' - 0"3
A-710
3' - 10"SS-01
WC-01
WC-01
2' - 4 3/4"WC-01
6' - 2"5' - 2"4' - 3 1/4"5' - 1"RB-01
WD-01 WD-01 WD-01
WC-01
D-G02
AP-01
GR-410
GR-403
PT-03PL-02
WC-01
RB-01
WC-01
2' - 9 3/4"
SF-01
RB-01
16
A-510
Sim
GR-410
GR-403 GR-400
W-H
PLAN ELEV
DUPLEX OUTLET
QUADPLEX OUTLET
GFCI OUTLET
CAT6, RJ45 INTERNET OUTLET
TELEPHONE OUTLET
WALL MOUNTED WIRELESS THERMOSTAT
POWER OUTLET WITH USB PORTS
CATV OUTLET
ELECTRICAL SWITCH
FLOOR OUTLET
POWER AND SIGNAL LEGEND:
POWER SUPPLY
CEILING FIXTURE LEGEND:
6" RECESSED CAN DOWNLIGHT
DECORATIVE FLUSH MOUNT LIGHT
PENDENT TYPE SPRINKLERS
SMOKE DETECTOR
EXHAUST FAN / GRILLE
LINEAR SURFACE MOUNTED CONTINUOUS LED SYSTEM W/ FIXED MOUNTING CLIPS & FROSTED LENS / 3 WATTS PER FOOT, MLV/FWD
ELECTRICAL OUTLET HEIGHTS (U.N.O)
TYPICAL OUTLET - 15" A.F.F
TYPICAL ACCESSIBLE WALL OUTLET - 18" A.F.F
BATHROOM VANITY OUTLET - 42" A.F.F
TYP. KITCHEN OUTLET - 42" A.F.F
ADA KITCHEN OUTLET - 46" A.F.F
ADA BATHROOM VANITY OUTLET - 44" A.F.F
ELECTRICAL SWITCH HEIGHTS (U.N.O)
SWITCH - 44" A.F.F
THERMOSTAT REMOTE - 48" A.F.F MAX TO TOP OF SWITCH
JUNCTION BOX
DOOR BELL HARDWIRED TO DOORBELL LIGHT - MOUNT @ 46" A.F.F TO CENTER OF BUTTON (FOR COMMUNICATIONS FEATURES ROOMS ONLY)
SD
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216UNIT INT. ELEVATIONS -EFFICIENCY STUDIO
A-411B
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
1/2" = 1'-0" Reference: 1 / A-411
1EFFICIENCY STUDIO ELEVATION A
Units x05, 307, 407, 507, x08, x27-x29, x31, x33-x34
1/2" = 1'-0" Reference: 1 / A-411
2EFFICIENCY STUDIO ELEVATION B
Units x05, 307, 407, 507, x08, x27-x29, x31, x33-x34
1/2" = 1'-0" Reference: 1 / A-411
3EFFICIENCY STUDIO ELEVATION C
Units x05, 307, 407, 507, x08, x27-x29, x31, x33-x34
1/2" = 1'-0" Reference: 1 / A-411
4EFFICIENCY STUDIO ELEVATION D
Units x05, 307, 407, 507, x08, x27-x29, x31, x33-x34
1/2" = 1'-0" Reference: 1 / A-411
5EFFICIENCY STUDIO ELEVATION A2
Units x05, 307, 407, 507, x08, x27-x29, x31, x33-x34
1/2" = 1'-0" Reference: 1 / A-411
6EFFICIENCY STUDIO ELEVATION C2
Units x05, 307, 407, 507, x08, x27-x29, x31, x33-x34
FFL
FFL
FFL
0'1' 2'4'
SCALE: 1/2" = 1'-0"
KEYNOTES - UNIT PLANS
1 ALIGN
2 GENERAL CONTRACTOR TO COORDINATE W/ FURNITUREFABRICATOR WHERE NECESSARY TO PROVIDE PROPERBLOCKING IN WALL FOR ITEM KEYNOTED
3 NO FINISHES UNDER THE SHOWER PAN / TUB
4 NO FINISHES UNDER MILLWORK CABINETRY
5 TV AND MOUNT NOT TO PROJECT MORE THAN 4" FROMWALL
6 MOTORIZED BLINDS. PROVIDE JUNCTION BOX BEHINDVALENCE FOR POWER CONNECTION AND PERMANENTLYINSTALLED SWITCH ON WALL TO CONTROL BLINDS.
7 SWITCH CONTROLLING UNDER CABINET LIGHTING ATKITCHEN TO BE GANGED WITH LIGHTING AT ENTRY
8 SWITCH CONTROLLING GARBAGE DISPOSAL-REFER TOHADG FOR ACCESSIBLE ROOM REQ'S.
9 DEDICATED CIRCUIT FOR GARBAGE DISPOSAL
10 MASTER SWITCH
11 DEDICATED CIRCUIT FOR INDUCTION COOKTOP
12 DEDICATED CIRCUIT FOR DISHWASHER
13 DEDICATED CIRCUIT FOR REFRIGERATOR
14 ELECTRIC VANITY MIRROR - HARDWIRE FIXTURE TO WALL-CONTRACTOR TO VERIFY JBOX TYPE TO ENSURE PROPERINSTALLATION AND BACKING FOR ITEM KEYNOTED
15 DOORBELL AND DOORBELL ON/OFF SWITCH(COMMUNICATION FEATURES ROOMS ONLY)SIGNAGE ASREQ'D.
16 PLACE TV OUTLETS AND CONNECTIONS ON WALL OUTSIDEAREA OF BRACKET AND CONCEALED FROM VIEW BY TV
17 DEDICATED CIRCUIT FOR WASHER/DRYER. DIRECT VENTTO EXTERIOR
FURNISHING SCHEDULE
GUESTROOM FURNISHINGS
GR-100 CHAIR - LOUNGE CHAIR WITH OTTOMAN
GR-102 CHAIR - COUNTER HEIGHT DESK CHAIR
GR-200 SCONCE - PIN-UP
GR-201 SCONCE - NIGHTSTAND
GR-202 LAMP - DESK
GR-307 NIGHTSTAND - SMALL
GR-308 NIGHTSTAND - REGULAR
GR-310 DESK - EFFICIENCY
GR-313 TABLE - ROUND SIDE TABLE
GR-319 CLOSET - EFFICIENCY SUITE
GR-325 VANITY - EFFICIENCY SUITE
GR-326 VANITY - STUDIO AND 1-BEDROOM SUITES
GR-400 STATIC DRAPARY PANELS
GR-403 ROLLER SHADE - GUESTROOMS (MANUAL,SHEER/BLACK-OUT, 8' W)
GR-410 VALENCE FOR 5' WINDOW
GR-500 ART
GR-501 ART
GR-505 WALL HOOK
GR-506 MIRROR - GUESTROOM FULL LENGTH
GR-508 MIRROR - GUESTROOM VANITY
GR-802 KITCHENETTE - EFFICIENCY SUITE
GR-900 GUESTROOM REFRIGERATOR
GR-901 GUESTROOM DISHWASHER
GR-902 GUESTROOM COOKTOP - 2 BURNER
GR-904 GARBAGE DISPOSAL 1/3HP
GR-905 MICROWAVE- WITH RECIRCULATING HOOD
GR-906GR-911 TELEVISION & TELEVISION MOUNT
GR-907 CLOCK/RADIO
GR-908 TELEPHONE - GUESTROOM
GR-ES BED - EFFICIENCY (GR-300, 303, 600)
GR-KS BED - KING (GR-301, 303, 600)
PLUMBING/MECHANICAL FIXTURES
PF-01 TOILET - GUESTROOM
PF-03 SHOWER BASE - 60" X 36" WITH LINEARDRAIN
PF-07 LAVATORY - UNDERMOUNT, 20" X 14"
PF-11 SHOWER HEAD - 2 IN 1
PF-13 SHOWER/TUB VALVE & CONTROL
PF-15 FAUCET - LAVATORY
PF-40 SINK - KITCHENETTE
PF-41 FAUCET - KITCHENETTE
TOILET ACCESSORIES
HD-01 DUAL TOILET PAPER HOLDER
HD-04 WALL-MOUNTED ROBE HOOK
HD-05.2 SLIDING SHOWER DOOR
HD-08 18" GRAB BAR
HD-16 BULK AMENITY DISPENSER ATSHOWERS/TUBS
HD-18 FOOT LEDGE FOR SHOWER
HD-18.1 SOAP SHELF
HD-21 BULK AMENITY DISPENSER AT LAVATORIES
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
Revision Schedule
Number Description Date
MATVSD
TVA-412B2
1
4
3
XE1/2W-H
D-G03A
D-G01A
12' - 5 1/2"15' - 0 1/4"3' - 4 1/4"
7' - 6 3/4"
2' - 0"5' - 1 3/4"2' - 0"7' - 2 1/4"
GR-320
GR-308
GR-201
GR-KM
GR-308
GR-201
GR-104
GR-311
GR-101
P3.1
GR-327
GR-507
GR-901
GR-902
GR-508
GR-906GR-911
GR-501GR-501
GR-900
14' - 10 1/2"
A-4241
CL-B8' - 0"
CL-B27' - 6"5' - 10"1' - 0"7' - 4"
3' - 2"3' - 9"1' - 10"1' - 10"3' - 8"1
1
A-424
3Sim
PLAN ELEV
DUPLEX OUTLET
QUADPLEX OUTLET
GFCI OUTLET
CAT6, RJ45 INTERNET OUTLET
TELEPHONE OUTLET
WALL MOUNTED WIRELESS THERMOSTAT
POWER OUTLET WITH USB PORTS
CATV OUTLET
ELECTRICAL SWITCH
FLOOR OUTLET
POWER AND SIGNAL LEGEND:
POWER SUPPLY
CEILING FIXTURE LEGEND:
6" RECESSED CAN DOWNLIGHT
DECORATIVE FLUSH MOUNT LIGHT
PENDENT TYPE SPRINKLERS
SMOKE DETECTOR
EXHAUST FAN / GRILLE
LINEAR SURFACE MOUNTED CONTINUOUS LED SYSTEM W/ FIXED MOUNTING CLIPS & FROSTED LENS / 3 WATTS PER FOOT, MLV/FWD
ELECTRICAL OUTLET HEIGHTS (U.N.O)
TYPICAL OUTLET - 15" A.F.F
TYPICAL ACCESSIBLE WALL OUTLET - 18" A.F.F
BATHROOM VANITY OUTLET - 42" A.F.F
TYP. KITCHEN OUTLET - 42" A.F.F
ADA KITCHEN OUTLET - 46" A.F.F
ADA BATHROOM VANITY OUTLET - 44" A.F.F
ELECTRICAL SWITCH HEIGHTS (U.N.O)
SWITCH - 44" A.F.F
THERMOSTAT REMOTE - 48" A.F.F MAX TO TOP OF SWITCH
JUNCTION BOX
DOOR BELL HARDWIRED TO DOORBELL LIGHT - MOUNT @ 46" A.F.F TO CENTER OF BUTTON (FOR COMMUNICATIONS FEATURES ROOMS ONLY)
SD
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216UNIT PLAN -EFFICIENCY STUDIOADA MOBILITY
A-412
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
0'1' 2'4'
SCALE: 1/2" = 1'-0"
1/2" = 1'-0" Reference: 1 / A-104
1EFFICIENCY ADA UNIT CONSTRUCTION PLAN
Units 403 (Roll-In), 503 (Tub)
22
2
2
2
5
2
13
1/2" = 1'-0"2EFFICIENCY ADA UNIT REFLECTED CEILING PLAN
Units 403 (Roll-In), 503 (Tub)
KEYNOTES - UNIT PLANS
1 ALIGN
2 GENERAL CONTRACTOR TO COORDINATE W/ FURNITUREFABRICATOR WHERE NECESSARY TO PROVIDE PROPERBLOCKING IN WALL FOR ITEM KEYNOTED
3 NO FINISHES UNDER THE SHOWER PAN / TUB
4 NO FINISHES UNDER MILLWORK CABINETRY
5 TV AND MOUNT NOT TO PROJECT MORE THAN 4" FROMWALL
6 MOTORIZED BLINDS. PROVIDE JUNCTION BOX BEHINDVALENCE FOR POWER CONNECTION AND PERMANENTLYINSTALLED SWITCH ON WALL TO CONTROL BLINDS.
7 SWITCH CONTROLLING UNDER CABINET LIGHTING ATKITCHEN TO BE GANGED WITH LIGHTING AT ENTRY
8 SWITCH CONTROLLING GARBAGE DISPOSAL-REFER TOHADG FOR ACCESSIBLE ROOM REQ'S.
9 DEDICATED CIRCUIT FOR GARBAGE DISPOSAL
10 MASTER SWITCH
11 DEDICATED CIRCUIT FOR INDUCTION COOKTOP
12 DEDICATED CIRCUIT FOR DISHWASHER
13 DEDICATED CIRCUIT FOR REFRIGERATOR
14 ELECTRIC VANITY MIRROR - HARDWIRE FIXTURE TO WALL-CONTRACTOR TO VERIFY JBOX TYPE TO ENSURE PROPERINSTALLATION AND BACKING FOR ITEM KEYNOTED
15 DOORBELL AND DOORBELL ON/OFF SWITCH(COMMUNICATION FEATURES ROOMS ONLY)SIGNAGE ASREQ'D.
16 PLACE TV OUTLETS AND CONNECTIONS ON WALL OUTSIDEAREA OF BRACKET AND CONCEALED FROM VIEW BY TV
17 DEDICATED CIRCUIT FOR WASHER/DRYER. DIRECT VENTTO EXTERIOR
FURNISHING SCHEDULE
GUESTROOM FURNISHINGS
GR-101 CHAIR - LOUNGE CHAIR IN STUIDOS
GR-104 CHAIR - ADA DESK CHAIR
GR-201 SCONCE - NIGHTSTAND
GR-308 NIGHTSTAND - REGULAR
GR-311 DESK - ACCESSIBLE EFFICIENCY
GR-320 CLOSET - ACCESSIBLE EFFICIENCY SUITE
GR-327 VANITY - ACCESSIBLE SUITES
GR-328 BATH CADDY - ACCESSIBLE SUITES
GR-400 STATIC DRAPARY PANELS
GR-403 ROLLER SHADE - GUESTROOMS (MANUAL,SHEER/BLACK-OUT, 8' W)
GR-410 VALENCE FOR 5' WINDOW
GR-501 ART
GR-506 MIRROR - GUESTROOM FULL LENGTH
GR-507 MIRROR - ADA VANITY
GR-508 MIRROR - GUESTROOM VANITY
GR-900 GUESTROOM REFRIGERATOR
GR-901 GUESTROOM DISHWASHER
GR-902 GUESTROOM COOKTOP - 2 BURNER
GR-906GR-911 TELEVISION & TELEVISION MOUNT
GR-907 CLOCK/RADIO
GR-908 TELEPHONE - GUESTROOM
GR-912 RECIRCULATING HOOD
GR-913 COUNTERTOP MICROWAVE
GR-KM BED - KING MOBILITY (GR-301, 304, 600, 602)
PLUMBING/MECHANICAL FIXTURES
PF-01 TOILET - GUESTROOM
PF-04 SHOWER BASE - 60" X 36" ADA ROLL-INSHOWER WITH EDGE TRENCH DRAIN
PF-07 LAVATORY - UNDERMOUNT, 20" X 14"
PF-10 SHOWER HEAD - HIGH
PF-12 SHOWER HEAD - HAND HELD ON SLIDE BAR
PF-13 SHOWER/TUB VALVE & CONTROL
PF-15 FAUCET - LAVATORY
PF-42 SINK - ADA KITCHENETTE
TOILET ACCESSORIES
HD-01 DUAL TOILET PAPER HOLDER
HD-04 WALL-MOUNTED ROBE HOOK
HD-04.1 TOWEL BAR
HD-05 CURVED CURTAIN ROD AND SHOWERCURTAIN
HD-08 18" GRAB BAR
HD-09 24" GRAB BAR
HD-10 42" GRAB BAR AT ADA BATHTUB
HD-11 36" GRAB BAR
HD-11.1 42" GRAB BAR
HD-14 ROLL-IN SHOWER SEAT
HD-16 BULK AMENITY DISPENSER ATSHOWERS/TUBS
HD-18.1 SOAP SHELF
HD-20 12" GRAB BAR
HD-21 BULK AMENITY DISPENSER AT LAVATORIES
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
Revision Schedule
Number Description Date
TTVTVTVA-412B2
1
4
3
SF-01
WC-01WC-01
WC-01
WC-01
WC-01
13' - 0 3/4"FULL TILE FULL TILEFULL TILEFULL TILE
CT-01
RES-01
CPT-01
CPT-10
6
A-510
Sim
9
A-510
Sim
7
A-510
Sim
1
A-510
Sim
PLAN ELEV
DUPLEX OUTLET
QUADPLEX OUTLET
GFCI OUTLET
CAT6, RJ45 INTERNET OUTLET
TELEPHONE OUTLET
WALL MOUNTED WIRELESS THERMOSTAT
POWER OUTLET WITH USB PORTS
CATV OUTLET
ELECTRICAL SWITCH
FLOOR OUTLET
POWER AND SIGNAL LEGEND:
POWER SUPPLY
CEILING FIXTURE LEGEND:
6" RECESSED CAN DOWNLIGHT
DECORATIVE FLUSH MOUNT LIGHT
PENDENT TYPE SPRINKLERS
SMOKE DETECTOR
EXHAUST FAN / GRILLE
LINEAR SURFACE MOUNTED CONTINUOUS LED SYSTEM W/ FIXED MOUNTING CLIPS & FROSTED LENS / 3 WATTS PER FOOT, MLV/FWD
ELECTRICAL OUTLET HEIGHTS (U.N.O)
TYPICAL OUTLET - 15" A.F.F
TYPICAL ACCESSIBLE WALL OUTLET - 18" A.F.F
BATHROOM VANITY OUTLET - 42" A.F.F
TYP. KITCHEN OUTLET - 42" A.F.F
ADA KITCHEN OUTLET - 46" A.F.F
ADA BATHROOM VANITY OUTLET - 44" A.F.F
ELECTRICAL SWITCH HEIGHTS (U.N.O)
SWITCH - 44" A.F.F
THERMOSTAT REMOTE - 48" A.F.F MAX TO TOP OF SWITCH
JUNCTION BOX
DOOR BELL HARDWIRED TO DOORBELL LIGHT - MOUNT @ 46" A.F.F TO CENTER OF BUTTON (FOR COMMUNICATIONS FEATURES ROOMS ONLY)
SD
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216UNIT PLAN -EFFICIENCY STUDIOADA MOBILITY - ELEC,DATA & FLOOR FINISHPLANA-412A
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
1/2" = 1'-0"3EFFICIENCY ADA UNIT ELECTRICAL AND DATA PLAN
Units 403 (Roll-In), 503 (Tub)
1/2" = 1'-0"1EFFICIENCY ADA UNIT FLOOR AND WALL FINISH PLAN
Units 403 (Roll-In), 503 (Tub)
0'1' 2'4'
SCALE: 1/2" = 1'-0"
15
7
10
12
8
9
11
13
14
3
4
16
KEYNOTES - UNIT PLANS
1 ALIGN
2 GENERAL CONTRACTOR TO COORDINATE W/ FURNITUREFABRICATOR WHERE NECESSARY TO PROVIDE PROPERBLOCKING IN WALL FOR ITEM KEYNOTED
3 NO FINISHES UNDER THE SHOWER PAN / TUB
4 NO FINISHES UNDER MILLWORK CABINETRY
5 TV AND MOUNT NOT TO PROJECT MORE THAN 4" FROMWALL
6 MOTORIZED BLINDS. PROVIDE JUNCTION BOX BEHINDVALENCE FOR POWER CONNECTION AND PERMANENTLYINSTALLED SWITCH ON WALL TO CONTROL BLINDS.
7 SWITCH CONTROLLING UNDER CABINET LIGHTING ATKITCHEN TO BE GANGED WITH LIGHTING AT ENTRY
8 SWITCH CONTROLLING GARBAGE DISPOSAL-REFER TOHADG FOR ACCESSIBLE ROOM REQ'S.
9 DEDICATED CIRCUIT FOR GARBAGE DISPOSAL
10 MASTER SWITCH
11 DEDICATED CIRCUIT FOR INDUCTION COOKTOP
12 DEDICATED CIRCUIT FOR DISHWASHER
13 DEDICATED CIRCUIT FOR REFRIGERATOR
14 ELECTRIC VANITY MIRROR - HARDWIRE FIXTURE TO WALL-CONTRACTOR TO VERIFY JBOX TYPE TO ENSURE PROPERINSTALLATION AND BACKING FOR ITEM KEYNOTED
15 DOORBELL AND DOORBELL ON/OFF SWITCH(COMMUNICATION FEATURES ROOMS ONLY)SIGNAGE ASREQ'D.
16 PLACE TV OUTLETS AND CONNECTIONS ON WALL OUTSIDEAREA OF BRACKET AND CONCEALED FROM VIEW BY TV
17 DEDICATED CIRCUIT FOR WASHER/DRYER. DIRECT VENTTO EXTERIOR
FURNISHING SCHEDULE
GUESTROOM FURNISHINGS
GR-101 CHAIR - LOUNGE CHAIR IN STUIDOS
GR-104 CHAIR - ADA DESK CHAIR
GR-201 SCONCE - NIGHTSTAND
GR-308 NIGHTSTAND - REGULAR
GR-311 DESK - ACCESSIBLE EFFICIENCY
GR-320 CLOSET - ACCESSIBLE EFFICIENCY SUITE
GR-327 VANITY - ACCESSIBLE SUITES
GR-328 BATH CADDY - ACCESSIBLE SUITES
GR-400 STATIC DRAPARY PANELS
GR-501 ART
GR-507 MIRROR - ADA VANITY
GR-508 MIRROR - GUESTROOM VANITY
GR-900 GUESTROOM REFRIGERATOR
GR-901 GUESTROOM DISHWASHER
GR-902 GUESTROOM COOKTOP - 2 BURNER
GR-906GR-911 TELEVISION & TELEVISION MOUNT
GR-907 CLOCK/RADIO
GR-908 TELEPHONE - GUESTROOM
GR-913 COUNTERTOP MICROWAVE
GR-KM BED - KING MOBILITY (GR-301, 304, 600, 602)
PLUMBING/MECHANICAL FIXTURES
PF-01 TOILET - GUESTROOM
PF-04 SHOWER BASE - 60" X 36" ADA ROLL-INSHOWER WITH EDGE TRENCH DRAIN
PF-07 LAVATORY - UNDERMOUNT, 20" X 14"
PF-12 SHOWER HEAD - HAND HELD ON SLIDE BAR
PF-13 SHOWER/TUB VALVE & CONTROL
PF-15 FAUCET - LAVATORY
PF-42 SINK - ADA KITCHENETTE
TOILET ACCESSORIES
HD-01 DUAL TOILET PAPER HOLDER
HD-04 WALL-MOUNTED ROBE HOOK
HD-04.1 TOWEL BAR
HD-08 18" GRAB BAR
HD-09 24" GRAB BAR
HD-11 36" GRAB BAR
HD-11.1 42" GRAB BAR
HD-14 ROLL-IN SHOWER SEAT
HD-16 BULK AMENITY DISPENSER ATSHOWERS/TUBS
HD-18.1 SOAP SHELF
HD-21 BULK AMENITY DISPENSER AT LAVATORIES
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
Revision Schedule
Number Description Date
TV
WC-01
RB-01RB-01
WC-01
D-G01A
PT-11PL-01
4' - 10 1/2"4' - 2"5' - 1"PL-02PT-03
WC-01
RB-01
WD-01
WD-01
WC-01
GR-901
GR-900
GR-902 AP-01
D-G02A
GR-410
GR-912
6
1' - 10"3' - 11 1/4"5' - 0"W-H
SF-01
RB-01
GR-410
16
A-510
Sim
GR-405
GR-400
GR-501
GR-505
D-G03A
1' - 5"
0' - 8"2' - 4 1/4"
RB-01
WC-01 WC-01
PT-03 PL-02 5' - 0"0' - 6"3' - 4"2' - 1"EQEQ2' - 3 1/4"
GR-410
PLAN ELEV
DUPLEX OUTLET
QUADPLEX OUTLET
GFCI OUTLET
CAT6, RJ45 INTERNET OUTLET
TELEPHONE OUTLET
WALL MOUNTED WIRELESS THERMOSTAT
POWER OUTLET WITH USB PORTS
CATV OUTLET
ELECTRICAL SWITCH
FLOOR OUTLET
POWER AND SIGNAL LEGEND:
POWER SUPPLY
CEILING FIXTURE LEGEND:
6" RECESSED CAN DOWNLIGHT
DECORATIVE FLUSH MOUNT LIGHT
PENDENT TYPE SPRINKLERS
SMOKE DETECTOR
EXHAUST FAN / GRILLE
LINEAR SURFACE MOUNTED CONTINUOUS LED SYSTEM W/ FIXED MOUNTING CLIPS & FROSTED LENS / 3 WATTS PER FOOT, MLV/FWD
ELECTRICAL OUTLET HEIGHTS (U.N.O)
TYPICAL OUTLET - 15" A.F.F
TYPICAL ACCESSIBLE WALL OUTLET - 18" A.F.F
BATHROOM VANITY OUTLET - 42" A.F.F
TYP. KITCHEN OUTLET - 42" A.F.F
ADA KITCHEN OUTLET - 46" A.F.F
ADA BATHROOM VANITY OUTLET - 44" A.F.F
ELECTRICAL SWITCH HEIGHTS (U.N.O)
SWITCH - 44" A.F.F
THERMOSTAT REMOTE - 48" A.F.F MAX TO TOP OF SWITCH
JUNCTION BOX
DOOR BELL HARDWIRED TO DOORBELL LIGHT - MOUNT @ 46" A.F.F TO CENTER OF BUTTON (FOR COMMUNICATIONS FEATURES ROOMS ONLY)
SD
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216UNIT INT. ELEVATIONS -EFFICIENCY STUDIOADA MOBILITY
A-412B
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
1/2" = 1'-0" Reference: 1 / A-412
1EFFICIENCY ADA ELEVATION A
Units 403 (Roll-In), 503 (Tub)
1/2" = 1'-0" Reference: 1 / A-412
2EFFICIENCY ADA ELEVATION B
Units 403 (Roll-In), 503 (Tub)
1/2" = 1'-0" Reference: 1 / A-412
3EFFICIENCY ADA ELEVATION C
Units 403 (Roll-In), 503 (Tub)
1/2" = 1'-0" Reference: 1 / A-412
4EFFICIENCY ADA ELEVATION D
Units 403 (Roll-In), 503 (Tub)
FFL
FFL
0'1' 2'4'
SCALE: 1/2" = 1'-0"
KEYNOTES - UNIT PLANS
1 ALIGN
2 GENERAL CONTRACTOR TO COORDINATE W/ FURNITUREFABRICATOR WHERE NECESSARY TO PROVIDE PROPERBLOCKING IN WALL FOR ITEM KEYNOTED
3 NO FINISHES UNDER THE SHOWER PAN / TUB
4 NO FINISHES UNDER MILLWORK CABINETRY
5 TV AND MOUNT NOT TO PROJECT MORE THAN 4" FROMWALL
6 MOTORIZED BLINDS. PROVIDE JUNCTION BOX BEHINDVALENCE FOR POWER CONNECTION AND PERMANENTLYINSTALLED SWITCH ON WALL TO CONTROL BLINDS.
7 SWITCH CONTROLLING UNDER CABINET LIGHTING ATKITCHEN TO BE GANGED WITH LIGHTING AT ENTRY
8 SWITCH CONTROLLING GARBAGE DISPOSAL-REFER TOHADG FOR ACCESSIBLE ROOM REQ'S.
9 DEDICATED CIRCUIT FOR GARBAGE DISPOSAL
10 MASTER SWITCH
11 DEDICATED CIRCUIT FOR INDUCTION COOKTOP
12 DEDICATED CIRCUIT FOR DISHWASHER
13 DEDICATED CIRCUIT FOR REFRIGERATOR
14 ELECTRIC VANITY MIRROR - HARDWIRE FIXTURE TO WALL-CONTRACTOR TO VERIFY JBOX TYPE TO ENSURE PROPERINSTALLATION AND BACKING FOR ITEM KEYNOTED
15 DOORBELL AND DOORBELL ON/OFF SWITCH(COMMUNICATION FEATURES ROOMS ONLY)SIGNAGE ASREQ'D.
16 PLACE TV OUTLETS AND CONNECTIONS ON WALL OUTSIDEAREA OF BRACKET AND CONCEALED FROM VIEW BY TV
17 DEDICATED CIRCUIT FOR WASHER/DRYER. DIRECT VENTTO EXTERIOR
FURNISHING SCHEDULE
GUESTROOM FURNISHINGS
GR-101 CHAIR - LOUNGE CHAIR IN STUIDOS
GR-104 CHAIR - ADA DESK CHAIR
GR-108 SOFA - SECTIONAL SLEEPER
GR-201 SCONCE - NIGHTSTAND
GR-205 LAMP - FLOOR LAMP
GR-307 NIGHTSTAND - SMALL
GR-308 NIGHTSTAND - REGULAR
GR-311 DESK - ACCESSIBLE EFFICIENCY
GR-312 TABLE - NESTING
GR-316 CONSOLE - LIVING ROOM (1-BEDROOM)
GR-319 CLOSET - EFFICIENCY SUITE
GR-320 CLOSET - ACCESSIBLE EFFICIENCY SUITE
GR-325 VANITY - EFFICIENCY SUITE
GR-326 VANITY - STUDIO AND 1-BEDROOM SUITES
GR-327 VANITY - ACCESSIBLE SUITES
GR-328 BATH CADDY - ACCESSIBLE SUITES
GR-400 STATIC DRAPARY PANELS
GR-403 ROLLER SHADE - GUESTROOMS (MANUAL,SHEER/BLACK-OUT, 8' W)
GR-405 ROLLER SHADE - GUESTROOMS (MANUAL,SHEER/BLACK-OUT, 8' W)
GR-410 VALENCE FOR 5' WINDOW
GR-501 ART
GR-505 WALL HOOK
GR-506 MIRROR - GUESTROOM FULL LENGTH
GR-507 MIRROR - ADA VANITY
GR-508 MIRROR - GUESTROOM VANITY
GR-900 GUESTROOM REFRIGERATOR
GR-901 GUESTROOM DISHWASHER
GR-902 GUESTROOM COOKTOP - 2 BURNER
GR-906GR-911 TELEVISION & TELEVISION MOUNT
GR-907 CLOCK/RADIO
GR-908 TELEPHONE - GUESTROOM
GR-912 RECIRCULATING HOOD
GR-913 COUNTERTOP MICROWAVE
GR-ES BED - EFFICIENCY (GR-300, 303, 600)
GR-KM BED - KING MOBILITY (GR-301, 304, 600, 602)
PLUMBING/MECHANICAL FIXTURES
PF-01 TOILET - GUESTROOM
PF-03 SHOWER BASE - 60" X 36" WITH LINEARDRAIN
PF-04 SHOWER BASE - 60" X 36" ADA ROLL-INSHOWER WITH EDGE TRENCH DRAIN
PF-07 LAVATORY - UNDERMOUNT, 20" X 14"
PF-10 SHOWER HEAD - HIGH
PF-11 SHOWER HEAD - 2 IN 1
PF-12 SHOWER HEAD - HAND HELD ON SLIDE BAR
PF-13 SHOWER/TUB VALVE & CONTROL
PF-15 FAUCET - LAVATORY
PF-42 SINK - ADA KITCHENETTE
TOILET ACCESSORIES
HD-01 DUAL TOILET PAPER HOLDER
HD-04 WALL-MOUNTED ROBE HOOK
HD-04.1 TOWEL BAR
HD-05.1 STRAIGHT CURTAIN ROD AND SHOWERCURTAIN
HD-05.2 SLIDING SHOWER DOOR
HD-08 18" GRAB BAR
HD-09 24" GRAB BAR
HD-11 36" GRAB BAR
HD-11.1 42" GRAB BAR
HD-12 DOOR-MOUNTED ROBE HOOK
HD-14 ROLL-IN SHOWER SEAT
HD-16 BULK AMENITY DISPENSER ATSHOWERS/TUBS
HD-18 FOOT LEDGE FOR SHOWER
HD-18.1 SOAP SHELF
HD-21 BULK AMENITY DISPENSER AT LAVATORIES
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
Revision Schedule
Number Description Date
MMAATVTV
SD
TV
402 SF
EFFICIENCYENLARGED
303
A-413B2
1
4
3
A-413B
5
6
A-4231
XE1/2
8' - 3 1/2"6' - 6 3/4"
2' - 4 1/2"5' - 11"
D-G03
4' - 2 1/2"6' - 9 1/2"7' - 9 3/4"12' - 10 1/4"11' - 6 1/4"
2' - 2 3/4"
P3.1
GR-906GR-911
GR-100
GR-313
GR-200
GR-308
GR-201
GR-201
GR-308
GR-ES
GR-310
GR-102
GR-325
GR-506
GR-908GR-907
GR-508
GR-501
D-G02A
AP-01
GR-902
GR-900
GR-901
GR-400GR-400
D-G06
GR-319CL-B27' - 6"
CL-B27' - 6"
CL-B8' - 0"
GR-400 GR-410 GR-400
VANITY2' - 4"2' - 4"3' - 4"5' - 3"1' - 0"7' - 2"
1
1
PLAN ELEV
DUPLEX OUTLET
QUADPLEX OUTLET
GFCI OUTLET
CAT6, RJ45 INTERNET OUTLET
TELEPHONE OUTLET
WALL MOUNTED WIRELESS THERMOSTAT
POWER OUTLET WITH USB PORTS
CATV OUTLET
ELECTRICAL SWITCH
FLOOR OUTLET
POWER AND SIGNAL LEGEND:
POWER SUPPLY
CEILING FIXTURE LEGEND:
6" RECESSED CAN DOWNLIGHT
DECORATIVE FLUSH MOUNT LIGHT
PENDENT TYPE SPRINKLERS
SMOKE DETECTOR
EXHAUST FAN / GRILLE
LINEAR SURFACE MOUNTED CONTINUOUS LED SYSTEM W/ FIXED MOUNTING CLIPS & FROSTED LENS / 3 WATTS PER FOOT, MLV/FWD
ELECTRICAL OUTLET HEIGHTS (U.N.O)
TYPICAL OUTLET - 15" A.F.F
TYPICAL ACCESSIBLE WALL OUTLET - 18" A.F.F
BATHROOM VANITY OUTLET - 42" A.F.F
TYP. KITCHEN OUTLET - 42" A.F.F
ADA KITCHEN OUTLET - 46" A.F.F
ADA BATHROOM VANITY OUTLET - 44" A.F.F
ELECTRICAL SWITCH HEIGHTS (U.N.O)
SWITCH - 44" A.F.F
THERMOSTAT REMOTE - 48" A.F.F MAX TO TOP OF SWITCH
JUNCTION BOX
DOOR BELL HARDWIRED TO DOORBELL LIGHT - MOUNT @ 46" A.F.F TO CENTER OF BUTTON (FOR COMMUNICATIONS FEATURES ROOMS ONLY)
SD
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216UNIT PLAN -EFFICIENCY STUDIOENLARGED
A-413
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
1/2" = 1'-0" Reference: 1 / A-103
1EFFICIENCY ENLARGED UNIT CONSTRUCTION PLAN
Units 203, 303
1/2" = 1'-0"2EFFICIENCY ENLARGED UNIT CONSTRUCTION PLAN
Units 203, 303
0'1' 2'4'
SCALE: 1/2" = 1'-0"
2
5
2
2
22
KEYNOTES - UNIT PLANS
1 ALIGN
2 GENERAL CONTRACTOR TO COORDINATE W/ FURNITUREFABRICATOR WHERE NECESSARY TO PROVIDE PROPERBLOCKING IN WALL FOR ITEM KEYNOTED
3 NO FINISHES UNDER THE SHOWER PAN / TUB
4 NO FINISHES UNDER MILLWORK CABINETRY
5 TV AND MOUNT NOT TO PROJECT MORE THAN 4" FROMWALL
6 MOTORIZED BLINDS. PROVIDE JUNCTION BOX BEHINDVALENCE FOR POWER CONNECTION AND PERMANENTLYINSTALLED SWITCH ON WALL TO CONTROL BLINDS.
7 SWITCH CONTROLLING UNDER CABINET LIGHTING ATKITCHEN TO BE GANGED WITH LIGHTING AT ENTRY
8 SWITCH CONTROLLING GARBAGE DISPOSAL-REFER TOHADG FOR ACCESSIBLE ROOM REQ'S.
9 DEDICATED CIRCUIT FOR GARBAGE DISPOSAL
10 MASTER SWITCH
11 DEDICATED CIRCUIT FOR INDUCTION COOKTOP
12 DEDICATED CIRCUIT FOR DISHWASHER
13 DEDICATED CIRCUIT FOR REFRIGERATOR
14 ELECTRIC VANITY MIRROR - HARDWIRE FIXTURE TO WALL-CONTRACTOR TO VERIFY JBOX TYPE TO ENSURE PROPERINSTALLATION AND BACKING FOR ITEM KEYNOTED
15 DOORBELL AND DOORBELL ON/OFF SWITCH(COMMUNICATION FEATURES ROOMS ONLY)SIGNAGE ASREQ'D.
16 PLACE TV OUTLETS AND CONNECTIONS ON WALL OUTSIDEAREA OF BRACKET AND CONCEALED FROM VIEW BY TV
17 DEDICATED CIRCUIT FOR WASHER/DRYER. DIRECT VENTTO EXTERIOR
FURNISHING SCHEDULE
GUESTROOM FURNISHINGS
GR-100 CHAIR - LOUNGE CHAIR WITH OTTOMAN
GR-102 CHAIR - COUNTER HEIGHT DESK CHAIR
GR-200 SCONCE - PIN-UP
GR-201 SCONCE - NIGHTSTAND
GR-308 NIGHTSTAND - REGULAR
GR-310 DESK - EFFICIENCY
GR-313 TABLE - ROUND SIDE TABLE
GR-316 CONSOLE - LIVING ROOM (1-BEDROOM)
GR-319 CLOSET - EFFICIENCY SUITE
GR-325 VANITY - EFFICIENCY SUITE
GR-327 VANITY - ACCESSIBLE SUITES
GR-400 STATIC DRAPARY PANELS
GR-403 ROLLER SHADE - GUESTROOMS (MANUAL,SHEER/BLACK-OUT, 8' W)
GR-410 VALENCE FOR 5' WINDOW
GR-501 ART
GR-503 ART- ENTRY
GR-505 WALL HOOK
GR-506 MIRROR - GUESTROOM FULL LENGTH
GR-507 MIRROR - ADA VANITY
GR-508 MIRROR - GUESTROOM VANITY
GR-802 KITCHENETTE - EFFICIENCY SUITE
GR-900 GUESTROOM REFRIGERATOR
GR-901 GUESTROOM DISHWASHER
GR-902 GUESTROOM COOKTOP - 2 BURNER
GR-904 GARBAGE DISPOSAL 1/3HP
GR-905 MICROWAVE- WITH RECIRCULATING HOOD
GR-906GR-911 TELEVISION & TELEVISION MOUNT
GR-907 CLOCK/RADIO
GR-908 TELEPHONE - GUESTROOM
GR-ES BED - EFFICIENCY (GR-300, 303, 600)
OWNER SPECIFIED - OWNER FURNISHED
OP-706 FIRE EXTINGUISHER CABINET
PLUMBING/MECHANICAL FIXTURES
PF-01 TOILET - GUESTROOM
PF-03 SHOWER BASE - 60" X 36" WITH LINEARDRAIN
PF-04 SHOWER BASE - 60" X 36" ADA ROLL-INSHOWER WITH EDGE TRENCH DRAIN
PF-07 LAVATORY - UNDERMOUNT, 20" X 14"
PF-11 SHOWER HEAD - 2 IN 1
PF-13 SHOWER/TUB VALVE & CONTROL
PF-15 FAUCET - LAVATORY
PF-40 SINK - KITCHENETTE
PF-41 FAUCET - KITCHENETTE
TOILET ACCESSORIES
HD-01 DUAL TOILET PAPER HOLDER
HD-02 DUAL TOILET PAPER HOLDER- ADA
HD-04 WALL-MOUNTED ROBE HOOK
HD-05.2 SLIDING SHOWER DOOR
HD-08 18" GRAB BAR
HD-11.1 42" GRAB BAR
HD-16 BULK AMENITY DISPENSER ATSHOWERS/TUBS
HD-18 FOOT LEDGE FOR SHOWER
HD-18.1 SOAP SHELF
HD-21 BULK AMENITY DISPENSER AT LAVATORIES
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
Revision Schedule
Number Description Date
TTVTV
TV
A-413B2
1
4
3
A-413B
5
6
SF-01
WC-01
WC-01
WC-01
WC-01
WC-01
WC-01
FULL TILE
FULL TILEFULL TILEFULL TILE
CPT-01
RES-01
CT-01
CPT-10
1
A-510
Sim
7
A-510
Sim
9
A-510
Sim
2
A-510
Sim
PLAN ELEV
DUPLEX OUTLET
QUADPLEX OUTLET
GFCI OUTLET
CAT6, RJ45 INTERNET OUTLET
TELEPHONE OUTLET
WALL MOUNTED WIRELESS THERMOSTAT
POWER OUTLET WITH USB PORTS
CATV OUTLET
ELECTRICAL SWITCH
FLOOR OUTLET
POWER AND SIGNAL LEGEND:
POWER SUPPLY
CEILING FIXTURE LEGEND:
6" RECESSED CAN DOWNLIGHT
DECORATIVE FLUSH MOUNT LIGHT
PENDENT TYPE SPRINKLERS
SMOKE DETECTOR
EXHAUST FAN / GRILLE
LINEAR SURFACE MOUNTED CONTINUOUS LED SYSTEM W/ FIXED MOUNTING CLIPS & FROSTED LENS / 3 WATTS PER FOOT, MLV/FWD
ELECTRICAL OUTLET HEIGHTS (U.N.O)
TYPICAL OUTLET - 15" A.F.F
TYPICAL ACCESSIBLE WALL OUTLET - 18" A.F.F
BATHROOM VANITY OUTLET - 42" A.F.F
TYP. KITCHEN OUTLET - 42" A.F.F
ADA KITCHEN OUTLET - 46" A.F.F
ADA BATHROOM VANITY OUTLET - 44" A.F.F
ELECTRICAL SWITCH HEIGHTS (U.N.O)
SWITCH - 44" A.F.F
THERMOSTAT REMOTE - 48" A.F.F MAX TO TOP OF SWITCH
JUNCTION BOX
DOOR BELL HARDWIRED TO DOORBELL LIGHT - MOUNT @ 46" A.F.F TO CENTER OF BUTTON (FOR COMMUNICATIONS FEATURES ROOMS ONLY)
SD
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216UNIT PLAN -EFFICIENCY STUDIOENLARGED - ELEC,DATA & FLOOR FINISHPLANA-413A
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
1/2" = 1'-0"1EFFICIENCY ENLARGED UNIT ELECTRICAL AND DATA PLAN
Units 203, 303
1/2" = 1'-0"2EFFICIENCY ENLARGED UNIT FLOOR AND WALL FINISH PLAN
Units 203, 303
0'1' 2'4'
SCALE: 1/2" = 1'-0"
15
12
8
9
11
13
14
7
10
16
3
KEYNOTES - UNIT PLANS
1 ALIGN
2 GENERAL CONTRACTOR TO COORDINATE W/ FURNITUREFABRICATOR WHERE NECESSARY TO PROVIDE PROPERBLOCKING IN WALL FOR ITEM KEYNOTED
3 NO FINISHES UNDER THE SHOWER PAN / TUB
4 NO FINISHES UNDER MILLWORK CABINETRY
5 TV AND MOUNT NOT TO PROJECT MORE THAN 4" FROMWALL
6 MOTORIZED BLINDS. PROVIDE JUNCTION BOX BEHINDVALENCE FOR POWER CONNECTION AND PERMANENTLYINSTALLED SWITCH ON WALL TO CONTROL BLINDS.
7 SWITCH CONTROLLING UNDER CABINET LIGHTING ATKITCHEN TO BE GANGED WITH LIGHTING AT ENTRY
8 SWITCH CONTROLLING GARBAGE DISPOSAL-REFER TOHADG FOR ACCESSIBLE ROOM REQ'S.
9 DEDICATED CIRCUIT FOR GARBAGE DISPOSAL
10 MASTER SWITCH
11 DEDICATED CIRCUIT FOR INDUCTION COOKTOP
12 DEDICATED CIRCUIT FOR DISHWASHER
13 DEDICATED CIRCUIT FOR REFRIGERATOR
14 ELECTRIC VANITY MIRROR - HARDWIRE FIXTURE TO WALL-CONTRACTOR TO VERIFY JBOX TYPE TO ENSURE PROPERINSTALLATION AND BACKING FOR ITEM KEYNOTED
15 DOORBELL AND DOORBELL ON/OFF SWITCH(COMMUNICATION FEATURES ROOMS ONLY)SIGNAGE ASREQ'D.
16 PLACE TV OUTLETS AND CONNECTIONS ON WALL OUTSIDEAREA OF BRACKET AND CONCEALED FROM VIEW BY TV
17 DEDICATED CIRCUIT FOR WASHER/DRYER. DIRECT VENTTO EXTERIOR
FURNISHING SCHEDULE
GUESTROOM FURNISHINGS
GR-100 CHAIR - LOUNGE CHAIR WITH OTTOMAN
GR-102 CHAIR - COUNTER HEIGHT DESK CHAIR
GR-200 SCONCE - PIN-UP
GR-201 SCONCE - NIGHTSTAND
GR-308 NIGHTSTAND - REGULAR
GR-310 DESK - EFFICIENCY
GR-313 TABLE - ROUND SIDE TABLE
GR-319 CLOSET - EFFICIENCY SUITE
GR-325 VANITY - EFFICIENCY SUITE
GR-400 STATIC DRAPARY PANELS
GR-501 ART
GR-503 ART- ENTRY
GR-506 MIRROR - GUESTROOM FULL LENGTH
GR-508 MIRROR - GUESTROOM VANITY
GR-802 KITCHENETTE - EFFICIENCY SUITE
GR-900 GUESTROOM REFRIGERATOR
GR-901 GUESTROOM DISHWASHER
GR-902 GUESTROOM COOKTOP - 2 BURNER
GR-904 GARBAGE DISPOSAL 1/3HP
GR-906GR-911 TELEVISION & TELEVISION MOUNT
GR-907 CLOCK/RADIO
GR-908 TELEPHONE - GUESTROOM
GR-ES BED - EFFICIENCY (GR-300, 303, 600)
PLUMBING/MECHANICAL FIXTURES
PF-01 TOILET - GUESTROOM
PF-03 SHOWER BASE - 60" X 36" WITH LINEARDRAIN
PF-07 LAVATORY - UNDERMOUNT, 20" X 14"
PF-11 SHOWER HEAD - 2 IN 1
PF-13 SHOWER/TUB VALVE & CONTROL
PF-15 FAUCET - LAVATORY
PF-40 SINK - KITCHENETTE
PF-41 FAUCET - KITCHENETTE
TOILET ACCESSORIES
HD-01 DUAL TOILET PAPER HOLDER
HD-05.2 SLIDING SHOWER DOOR
HD-08 18" GRAB BAR
HD-16 BULK AMENITY DISPENSER ATSHOWERS/TUBS
HD-18 FOOT LEDGE FOR SHOWER
HD-18.1 SOAP SHELF
HD-21 BULK AMENITY DISPENSER AT LAVATORIES
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
Revision Schedule
Number Description Date
TV
WC-01WD-01
WD-01
5' - 1"6' - 2"4' - 3 1/4"
WC-01
RB-01
0' - 9 1/2"
GR-902
GR-900
GR-901
AP-01
D-G02A
GR-410
WC-01
WD-01WD-01
5' - 2"1' - 10 3/4"GR-403
3' - 10"W-H
RB-01
RB-01
SS-01
WC-01
GR-410
GR-403
GR-400
WC-01
RB-01
WC-01
RB-01
GR-505
0' - 8"
2' - 10 3/4"5' - 0"0' - 6"WC-01WC-01
RB-01
WD-01
WD-01
SS-01
W-H
4' - 2"5' - 5 1/2"
SF-01
RB-01
GR-410
16
A-510
Sim
GR-403
GR-400
PLAN ELEV
DUPLEX OUTLET
QUADPLEX OUTLET
GFCI OUTLET
CAT6, RJ45 INTERNET OUTLET
TELEPHONE OUTLET
WALL MOUNTED WIRELESS THERMOSTAT
POWER OUTLET WITH USB PORTS
CATV OUTLET
ELECTRICAL SWITCH
FLOOR OUTLET
POWER AND SIGNAL LEGEND:
POWER SUPPLY
CEILING FIXTURE LEGEND:
6" RECESSED CAN DOWNLIGHT
DECORATIVE FLUSH MOUNT LIGHT
PENDENT TYPE SPRINKLERS
SMOKE DETECTOR
EXHAUST FAN / GRILLE
LINEAR SURFACE MOUNTED CONTINUOUS LED SYSTEM W/ FIXED MOUNTING CLIPS & FROSTED LENS / 3 WATTS PER FOOT, MLV/FWD
ELECTRICAL OUTLET HEIGHTS (U.N.O)
TYPICAL OUTLET - 15" A.F.F
TYPICAL ACCESSIBLE WALL OUTLET - 18" A.F.F
BATHROOM VANITY OUTLET - 42" A.F.F
TYP. KITCHEN OUTLET - 42" A.F.F
ADA KITCHEN OUTLET - 46" A.F.F
ADA BATHROOM VANITY OUTLET - 44" A.F.F
ELECTRICAL SWITCH HEIGHTS (U.N.O)
SWITCH - 44" A.F.F
THERMOSTAT REMOTE - 48" A.F.F MAX TO TOP OF SWITCH
JUNCTION BOX
DOOR BELL HARDWIRED TO DOORBELL LIGHT - MOUNT @ 46" A.F.F TO CENTER OF BUTTON (FOR COMMUNICATIONS FEATURES ROOMS ONLY)
SD
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216UNIT INT. ELEVATIONS -EFFICIENCY STUDIOENLARGED
A-413B
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
FFL
FFL
1/2" = 1'-0" Reference: 1 / A-413
1EFFICIENCY ENLARGED ELEVATION A
Units 203, 303
1/2" = 1'-0" Reference: 1 / A-413
2EFFICIENCY ENLARGED ELEVATION B
Units 203, 303
1/2" = 1'-0" Reference: 1 / A-413
3EFFICIENCY ENLARGED ELEVATION C
Units 203, 303
1/2" = 1'-0" Reference: 1 / A-413
4EFFICIENCY ENLARGED ELEVATION D
Units 203, 303
FFL
1/2" = 1'-0" Reference: 1 / A-413
5EFFICIENCY ENLARGED ELEVATION E
Units 203, 303 1/2" = 1'-0" Reference: 1 / A-413
6EFFICIENCY ENLARGED ELEVATION F
Units 203, 303
0'1' 2'4'
SCALE: 1/2" = 1'-0"
KEYNOTES - UNIT PLANS
1 ALIGN
2 GENERAL CONTRACTOR TO COORDINATE W/ FURNITUREFABRICATOR WHERE NECESSARY TO PROVIDE PROPERBLOCKING IN WALL FOR ITEM KEYNOTED
3 NO FINISHES UNDER THE SHOWER PAN / TUB
4 NO FINISHES UNDER MILLWORK CABINETRY
5 TV AND MOUNT NOT TO PROJECT MORE THAN 4" FROMWALL
6 MOTORIZED BLINDS. PROVIDE JUNCTION BOX BEHINDVALENCE FOR POWER CONNECTION AND PERMANENTLYINSTALLED SWITCH ON WALL TO CONTROL BLINDS.
7 SWITCH CONTROLLING UNDER CABINET LIGHTING ATKITCHEN TO BE GANGED WITH LIGHTING AT ENTRY
8 SWITCH CONTROLLING GARBAGE DISPOSAL-REFER TOHADG FOR ACCESSIBLE ROOM REQ'S.
9 DEDICATED CIRCUIT FOR GARBAGE DISPOSAL
10 MASTER SWITCH
11 DEDICATED CIRCUIT FOR INDUCTION COOKTOP
12 DEDICATED CIRCUIT FOR DISHWASHER
13 DEDICATED CIRCUIT FOR REFRIGERATOR
14 ELECTRIC VANITY MIRROR - HARDWIRE FIXTURE TO WALL-CONTRACTOR TO VERIFY JBOX TYPE TO ENSURE PROPERINSTALLATION AND BACKING FOR ITEM KEYNOTED
15 DOORBELL AND DOORBELL ON/OFF SWITCH(COMMUNICATION FEATURES ROOMS ONLY)SIGNAGE ASREQ'D.
16 PLACE TV OUTLETS AND CONNECTIONS ON WALL OUTSIDEAREA OF BRACKET AND CONCEALED FROM VIEW BY TV
17 DEDICATED CIRCUIT FOR WASHER/DRYER. DIRECT VENTTO EXTERIOR
FURNISHING SCHEDULE
GUESTROOM FURNISHINGS
GR-100 CHAIR - LOUNGE CHAIR WITH OTTOMAN
GR-101 CHAIR - LOUNGE CHAIR IN STUIDOS
GR-102 CHAIR - COUNTER HEIGHT DESK CHAIR
GR-105 SOFA - SLEEP BETWEEN ARMS
GR-200 SCONCE - PIN-UP
GR-201 SCONCE - NIGHTSTAND
GR-205 LAMP - FLOOR LAMP
GR-307 NIGHTSTAND - SMALL
GR-308 NIGHTSTAND - REGULAR
GR-310 DESK - EFFICIENCY
GR-312 TABLE - NESTING
GR-313 TABLE - ROUND SIDE TABLE
GR-316 CONSOLE - LIVING ROOM (1-BEDROOM)
GR-319 CLOSET - EFFICIENCY SUITE
GR-325 VANITY - EFFICIENCY SUITE
GR-327 VANITY - ACCESSIBLE SUITES
GR-328 BATH CADDY - ACCESSIBLE SUITES
GR-400 STATIC DRAPARY PANELS
GR-403 ROLLER SHADE - GUESTROOMS (MANUAL,SHEER/BLACK-OUT, 8' W)
GR-405 ROLLER SHADE - GUESTROOMS (MANUAL,SHEER/BLACK-OUT, 8' W)
GR-410 VALENCE FOR 5' WINDOW
GR-501 ART
GR-503 ART- ENTRY
GR-505 WALL HOOK
GR-506 MIRROR - GUESTROOM FULL LENGTH
GR-507 MIRROR - ADA VANITY
GR-508 MIRROR - GUESTROOM VANITY
GR-802 KITCHENETTE - EFFICIENCY SUITE
GR-900 GUESTROOM REFRIGERATOR
GR-901 GUESTROOM DISHWASHER
GR-902 GUESTROOM COOKTOP - 2 BURNER
GR-904 GARBAGE DISPOSAL 1/3HP
GR-905 MICROWAVE- WITH RECIRCULATING HOOD
GR-906GR-911 TELEVISION & TELEVISION MOUNT
GR-907 CLOCK/RADIO
GR-908 TELEPHONE - GUESTROOM
GR-ES BED - EFFICIENCY (GR-300, 303, 600)
PLUMBING/MECHANICAL FIXTURES
PF-01 TOILET - GUESTROOM
PF-03 SHOWER BASE - 60" X 36" WITH LINEARDRAIN
PF-06 BATHTUB - 5' X 32" WITH SIDE LEDGE
PF-07 LAVATORY - UNDERMOUNT, 20" X 14"
PF-10 SHOWER HEAD - HIGH
PF-11 SHOWER HEAD - 2 IN 1
PF-12 SHOWER HEAD - HAND HELD ON SLIDE BAR
PF-13 SHOWER/TUB VALVE & CONTROL
PF-14 BATHTUB FILL FAUCET
PF-15 FAUCET - LAVATORY
PF-40 SINK - KITCHENETTE
PF-41 FAUCET - KITCHENETTE
TOILET ACCESSORIES
HD-01 DUAL TOILET PAPER HOLDER
HD-02 DUAL TOILET PAPER HOLDER- ADA
HD-04 WALL-MOUNTED ROBE HOOK
HD-04.1 TOWEL BAR
HD-05 CURVED CURTAIN ROD AND SHOWERCURTAIN
HD-05.2 SLIDING SHOWER DOOR
HD-08 18" GRAB BAR
HD-09 24" GRAB BAR
HD-10 42" GRAB BAR AT ADA BATHTUB
HD-11 36" GRAB BAR
HD-11.1 42" GRAB BAR
HD-14.1 ROLL-IN SHOWER SEAT
HD-16 BULK AMENITY DISPENSER ATSHOWERS/TUBS
HD-18 FOOT LEDGE FOR SHOWER
HD-18.1 SOAP SHELF
HD-20 12" GRAB BAR
HD-21 BULK AMENITY DISPENSER AT LAVATORIES
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
Revision Schedule
Number Description Date
MMAATVSD
TV
OF-705 OF-702OF-702
D-G04
A-414B4
1
2
3
D-G02
P3.1
GR-400
GR-400
8' - 0"
4' - 7"
12' - 4"6' - 1"11' - 10"4' - 10 3/4"6' - 5"22' - 11"D-G01
D-G03
GR-504GR-908
GR-907
GR-308
GR-KS
GR-201
GR-906GR-911
GR-801
GR-103
GR-103
GR-318
GR-321
GR-105
GR-312
GR-308
GR-201
GR-901
18' - 5"
A-4251
GR-508
GR-902
GR-506
OF-702AOF-705OF-702A
5' - 1"11' - 6 1/2"
D-G04
3' - 1 3/4"1' - 5"1' - 5"4' - 6"4' - 6"
OF BED
OF TABLE
2' - 1 1/4"
A-4253
CL-B8' - 0"
CL-B27' - 6"
CL-B27' - 6"
PLAN ELEV
DUPLEX OUTLET
QUADPLEX OUTLET
GFCI OUTLET
CAT6, RJ45 INTERNET OUTLET
TELEPHONE OUTLET
WALL MOUNTED WIRELESS THERMOSTAT
POWER OUTLET WITH USB PORTS
CATV OUTLET
ELECTRICAL SWITCH
FLOOR OUTLET
POWER AND SIGNAL LEGEND:
POWER SUPPLY
CEILING FIXTURE LEGEND:
6" RECESSED CAN DOWNLIGHT
DECORATIVE FLUSH MOUNT LIGHT
PENDENT TYPE SPRINKLERS
SMOKE DETECTOR
EXHAUST FAN / GRILLE
LINEAR SURFACE MOUNTED CONTINUOUS LED SYSTEM W/ FIXED MOUNTING CLIPS & FROSTED LENS / 3 WATTS PER FOOT, MLV/FWD
ELECTRICAL OUTLET HEIGHTS (U.N.O)
TYPICAL OUTLET - 15" A.F.F
TYPICAL ACCESSIBLE WALL OUTLET - 18" A.F.F
BATHROOM VANITY OUTLET - 42" A.F.F
TYP. KITCHEN OUTLET - 42" A.F.F
ADA KITCHEN OUTLET - 46" A.F.F
ADA BATHROOM VANITY OUTLET - 44" A.F.F
ELECTRICAL SWITCH HEIGHTS (U.N.O)
SWITCH - 44" A.F.F
THERMOSTAT REMOTE - 48" A.F.F MAX TO TOP OF SWITCH
JUNCTION BOX
DOOR BELL HARDWIRED TO DOORBELL LIGHT - MOUNT @ 46" A.F.F TO CENTER OF BUTTON (FOR COMMUNICATIONS FEATURES ROOMS ONLY)
SD
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216UNIT PLAN - KINGSTUDIO
A-414
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
1/2" = 1'-0" Reference: 1 / A-102
1KING STUDIO CONSTRUCTION PLAN
Units x04, x14, x16, x18-x21, x23, x25-x26, x30, x37
1/2" = 1'-0" Reference: 1 / A-102
2KING STUDIO BALCONY PLAN
Units x18, x21, x23, x25, 237, 337, 437, 537
1/2" = 1'-0"3KING STUDIO REFLECTED CEILING PLAN
Units x04, x14, x16, x18-x21, x23, x25-x26, x30, x37
1/2" = 1'-0" Reference: 1 / A-101
4KING STUDIO LANAI PLAN
Unit 137
0'1' 2'4'
SCALE: 1/2" = 1'-0"
2
2
2
2
5
2
1
1
1
KEYNOTES - UNIT PLANS
1 ALIGN
2 GENERAL CONTRACTOR TO COORDINATE W/ FURNITUREFABRICATOR WHERE NECESSARY TO PROVIDE PROPERBLOCKING IN WALL FOR ITEM KEYNOTED
3 NO FINISHES UNDER THE SHOWER PAN / TUB
4 NO FINISHES UNDER MILLWORK CABINETRY
5 TV AND MOUNT NOT TO PROJECT MORE THAN 4" FROMWALL
6 MOTORIZED BLINDS. PROVIDE JUNCTION BOX BEHINDVALENCE FOR POWER CONNECTION AND PERMANENTLYINSTALLED SWITCH ON WALL TO CONTROL BLINDS.
7 SWITCH CONTROLLING UNDER CABINET LIGHTING ATKITCHEN TO BE GANGED WITH LIGHTING AT ENTRY
8 SWITCH CONTROLLING GARBAGE DISPOSAL-REFER TOHADG FOR ACCESSIBLE ROOM REQ'S.
9 DEDICATED CIRCUIT FOR GARBAGE DISPOSAL
10 MASTER SWITCH
11 DEDICATED CIRCUIT FOR INDUCTION COOKTOP
12 DEDICATED CIRCUIT FOR DISHWASHER
13 DEDICATED CIRCUIT FOR REFRIGERATOR
14 ELECTRIC VANITY MIRROR - HARDWIRE FIXTURE TO WALL-CONTRACTOR TO VERIFY JBOX TYPE TO ENSURE PROPERINSTALLATION AND BACKING FOR ITEM KEYNOTED
15 DOORBELL AND DOORBELL ON/OFF SWITCH(COMMUNICATION FEATURES ROOMS ONLY)SIGNAGE ASREQ'D.
16 PLACE TV OUTLETS AND CONNECTIONS ON WALL OUTSIDEAREA OF BRACKET AND CONCEALED FROM VIEW BY TV
17 DEDICATED CIRCUIT FOR WASHER/DRYER. DIRECT VENTTO EXTERIOR
FURNISHING SCHEDULE
GUESTROOM FURNISHINGS
GR-103 CHAIR - KITCHEN STOOL
GR-105 SOFA - SLEEP BETWEEN ARMS
GR-201 SCONCE - NIGHTSTAND
GR-203 PENDANT LIGHT - PRODUCTIVITY TABLE
GR-205 LAMP - FLOOR LAMP
GR-308 NIGHTSTAND - REGULAR
GR-312 TABLE - NESTING
GR-314 TABLE - PRODUCTIVITY TABLE (STUDIO)
GR-318 DRESSER - HIGHBOY
GR-321 CLOSET - KING STUDIO SUITE
GR-326 VANITY - STUDIO AND 1-BEDROOM SUITES
GR-400 STATIC DRAPARY PANELS
GR-403 ROLLER SHADE - GUESTROOMS (MANUAL,SHEER/BLACK-OUT, 8' W)
GR-412 VALENCE FOR 8' WINDOW
GR-503 ART- ENTRY
GR-504 ART- SLEEPING/LIVING
GR-505 WALL HOOK
GR-506 MIRROR - GUESTROOM FULL LENGTH
GR-508 MIRROR - GUESTROOM VANITY
GR-800 KITCHENETTE - 1-BEDROOM
GR-900 GUESTROOM REFRIGERATOR
GR-901 GUESTROOM DISHWASHER
GR-902 GUESTROOM COOKTOP - 2 BURNER
GR-904 GARBAGE DISPOSAL 1/3HP
GR-905 MICROWAVE- WITH RECIRCULATING HOOD
GR-906GR-911 TELEVISION & TELEVISION MOUNT
GR-907 CLOCK/RADIO
GR-908 TELEPHONE - GUESTROOM
GR-KS BED - KING (GR-301, 303, 600)
HILTON SPECIFIED - OWNER FURNISHED
OF-702 CHAIR - OUDOOR DINING CHAIR
OF-702A CHAIR - BALCONY CHAIR
OF-705 TABLE - 17" D OUTDOOR SIDE TABLE
PLUMBING/MECHANICAL FIXTURES
PF-01 TOILET - GUESTROOM
PF-03 SHOWER BASE - 60" X 36" WITH LINEARDRAIN
PF-07 LAVATORY - UNDERMOUNT, 20" X 14"
PF-11 SHOWER HEAD - 2 IN 1
PF-13 SHOWER/TUB VALVE & CONTROL
PF-15 FAUCET - LAVATORY
PF-40 SINK - KITCHENETTE
PF-41 FAUCET - KITCHENETTE
TOILET ACCESSORIES
HD-01 DUAL TOILET PAPER HOLDER
HD-04 WALL-MOUNTED ROBE HOOK
HD-04.1 TOWEL BAR
HD-05.2 SLIDING SHOWER DOOR
HD-08 18" GRAB BAR
HD-16 BULK AMENITY DISPENSER ATSHOWERS/TUBS
HD-18 FOOT LEDGE FOR SHOWER
HD-18.1 SOAP SHELF
HD-21 BULK AMENITY DISPENSER AT LAVATORIES
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
Revision Schedule
Number Description Date
TVTV
A-414B4
1
2
3
SF-01
WC-01
WC-01
WC-01
WC-01
WC-01
CPT-10
RES-01
CPT-01
CT-01
FULL TILEFULL TILE
1
A-510
Sim
8' - 5 3/4"
7
A-510
Sim
1
A-510
Sim
9
A-510
Sim
PLAN ELEV
DUPLEX OUTLET
QUADPLEX OUTLET
GFCI OUTLET
CAT6, RJ45 INTERNET OUTLET
TELEPHONE OUTLET
WALL MOUNTED WIRELESS THERMOSTAT
POWER OUTLET WITH USB PORTS
CATV OUTLET
ELECTRICAL SWITCH
FLOOR OUTLET
POWER AND SIGNAL LEGEND:
POWER SUPPLY
CEILING FIXTURE LEGEND:
6" RECESSED CAN DOWNLIGHT
DECORATIVE FLUSH MOUNT LIGHT
PENDENT TYPE SPRINKLERS
SMOKE DETECTOR
EXHAUST FAN / GRILLE
LINEAR SURFACE MOUNTED CONTINUOUS LED SYSTEM W/ FIXED MOUNTING CLIPS & FROSTED LENS / 3 WATTS PER FOOT, MLV/FWD
ELECTRICAL OUTLET HEIGHTS (U.N.O)
TYPICAL OUTLET - 15" A.F.F
TYPICAL ACCESSIBLE WALL OUTLET - 18" A.F.F
BATHROOM VANITY OUTLET - 42" A.F.F
TYP. KITCHEN OUTLET - 42" A.F.F
ADA KITCHEN OUTLET - 46" A.F.F
ADA BATHROOM VANITY OUTLET - 44" A.F.F
ELECTRICAL SWITCH HEIGHTS (U.N.O)
SWITCH - 44" A.F.F
THERMOSTAT REMOTE - 48" A.F.F MAX TO TOP OF SWITCH
JUNCTION BOX
DOOR BELL HARDWIRED TO DOORBELL LIGHT - MOUNT @ 46" A.F.F TO CENTER OF BUTTON (FOR COMMUNICATIONS FEATURES ROOMS ONLY)
SD
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216UNIT PLAN - KINGSTUDIO - ELEC, DATA &FLOOR FINISH PLAN
A-414A
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
1/2" = 1'-0"1KING STUDIO ELECTRICAL & DATA PLAN
Units x04, x14, x16, x18-x21, x23, x25-x26, x30, x37
1/2" = 1'-0"2KING STUDIO FLOOR & WALL FINISH PLAN
Units x04, x14, x16, x18-x21, x23, x25-x26, x30, x37 0'1' 2'4'
SCALE: 1/2" = 1'-0"
3
15
12
8
9
11
13
7
10
16
KEYNOTES - UNIT PLANS
1 ALIGN
2 GENERAL CONTRACTOR TO COORDINATE W/ FURNITUREFABRICATOR WHERE NECESSARY TO PROVIDE PROPERBLOCKING IN WALL FOR ITEM KEYNOTED
3 NO FINISHES UNDER THE SHOWER PAN / TUB
4 NO FINISHES UNDER MILLWORK CABINETRY
5 TV AND MOUNT NOT TO PROJECT MORE THAN 4" FROMWALL
6 MOTORIZED BLINDS. PROVIDE JUNCTION BOX BEHINDVALENCE FOR POWER CONNECTION AND PERMANENTLYINSTALLED SWITCH ON WALL TO CONTROL BLINDS.
7 SWITCH CONTROLLING UNDER CABINET LIGHTING ATKITCHEN TO BE GANGED WITH LIGHTING AT ENTRY
8 SWITCH CONTROLLING GARBAGE DISPOSAL-REFER TOHADG FOR ACCESSIBLE ROOM REQ'S.
9 DEDICATED CIRCUIT FOR GARBAGE DISPOSAL
10 MASTER SWITCH
11 DEDICATED CIRCUIT FOR INDUCTION COOKTOP
12 DEDICATED CIRCUIT FOR DISHWASHER
13 DEDICATED CIRCUIT FOR REFRIGERATOR
14 ELECTRIC VANITY MIRROR - HARDWIRE FIXTURE TO WALL-CONTRACTOR TO VERIFY JBOX TYPE TO ENSURE PROPERINSTALLATION AND BACKING FOR ITEM KEYNOTED
15 DOORBELL AND DOORBELL ON/OFF SWITCH(COMMUNICATION FEATURES ROOMS ONLY)SIGNAGE ASREQ'D.
16 PLACE TV OUTLETS AND CONNECTIONS ON WALL OUTSIDEAREA OF BRACKET AND CONCEALED FROM VIEW BY TV
17 DEDICATED CIRCUIT FOR WASHER/DRYER. DIRECT VENTTO EXTERIOR
FURNISHING SCHEDULE
GUESTROOM FURNISHINGS
GR-103 CHAIR - KITCHEN STOOL
GR-105 SOFA - SLEEP BETWEEN ARMS
GR-201 SCONCE - NIGHTSTAND
GR-205 LAMP - FLOOR LAMP
GR-308 NIGHTSTAND - REGULAR
GR-312 TABLE - NESTING
GR-314 TABLE - PRODUCTIVITY TABLE (STUDIO)
GR-318 DRESSER - HIGHBOY
GR-321 CLOSET - KING STUDIO SUITE
GR-326 VANITY - STUDIO AND 1-BEDROOM SUITES
GR-400 STATIC DRAPARY PANELS
GR-504 ART- SLEEPING/LIVING
GR-506 MIRROR - GUESTROOM FULL LENGTH
GR-508 MIRROR - GUESTROOM VANITY
GR-800 KITCHENETTE - 1-BEDROOM
GR-900 GUESTROOM REFRIGERATOR
GR-901 GUESTROOM DISHWASHER
GR-902 GUESTROOM COOKTOP - 2 BURNER
GR-904 GARBAGE DISPOSAL 1/3HP
GR-906GR-911 TELEVISION & TELEVISION MOUNT
GR-907 CLOCK/RADIO
GR-908 TELEPHONE - GUESTROOM
GR-KS BED - KING (GR-301, 303, 600)
PLUMBING/MECHANICAL FIXTURES
PF-01 TOILET - GUESTROOM
PF-03 SHOWER BASE - 60" X 36" WITH LINEARDRAIN
PF-07 LAVATORY - UNDERMOUNT, 20" X 14"
PF-11 SHOWER HEAD - 2 IN 1
PF-13 SHOWER/TUB VALVE & CONTROL
PF-15 FAUCET - LAVATORY
PF-40 SINK - KITCHENETTE
PF-41 FAUCET - KITCHENETTE
TOILET ACCESSORIES
HD-01 DUAL TOILET PAPER HOLDER
HD-04.1 TOWEL BAR
HD-05.2 SLIDING SHOWER DOOR
HD-08 18" GRAB BAR
HD-16 BULK AMENITY DISPENSER ATSHOWERS/TUBS
HD-18 FOOT LEDGE FOR SHOWER
HD-18.1 SOAP SHELF
HD-21 BULK AMENITY DISPENSER AT LAVATORIES
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
Revision Schedule
Number Description Date
TV
WC-01
0' - 8"
2' - 3 1/2"5' - 0"RB-01
WD-01
WD-01
GR-505
D-G01
PT-11PL-01
GR-504
GR-321
5' - 2"3' - 2 1/4"2' - 2 1/4"
D-G03
GR-503
GR-508
GR-318
GR-KS
PT-03PL-02WC-01WC-01
RB-01
SF-01
W-G
RB-01
SF-01
GR-412
GR-400GR-403
2' - 7 1/4"
WC-01
PT-03 PL-02 5' - 1"4' - 2"RB-01
WD-01 WD-01
WC-01
D-G02
PLAN ELEV
DUPLEX OUTLET
QUADPLEX OUTLET
GFCI OUTLET
CAT6, RJ45 INTERNET OUTLET
TELEPHONE OUTLET
WALL MOUNTED WIRELESS THERMOSTAT
POWER OUTLET WITH USB PORTS
CATV OUTLET
ELECTRICAL SWITCH
FLOOR OUTLET
POWER AND SIGNAL LEGEND:
POWER SUPPLY
CEILING FIXTURE LEGEND:
6" RECESSED CAN DOWNLIGHT
DECORATIVE FLUSH MOUNT LIGHT
PENDENT TYPE SPRINKLERS
SMOKE DETECTOR
EXHAUST FAN / GRILLE
LINEAR SURFACE MOUNTED CONTINUOUS LED SYSTEM W/ FIXED MOUNTING CLIPS & FROSTED LENS / 3 WATTS PER FOOT, MLV/FWD
ELECTRICAL OUTLET HEIGHTS (U.N.O)
TYPICAL OUTLET - 15" A.F.F
TYPICAL ACCESSIBLE WALL OUTLET - 18" A.F.F
BATHROOM VANITY OUTLET - 42" A.F.F
TYP. KITCHEN OUTLET - 42" A.F.F
ADA KITCHEN OUTLET - 46" A.F.F
ADA BATHROOM VANITY OUTLET - 44" A.F.F
ELECTRICAL SWITCH HEIGHTS (U.N.O)
SWITCH - 44" A.F.F
THERMOSTAT REMOTE - 48" A.F.F MAX TO TOP OF SWITCH
JUNCTION BOX
DOOR BELL HARDWIRED TO DOORBELL LIGHT - MOUNT @ 46" A.F.F TO CENTER OF BUTTON (FOR COMMUNICATIONS FEATURES ROOMS ONLY)
SD
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216UNIT INT. ELEVATIONS -KING STUDIO
A-414B
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
1/2" = 1'-0" Reference: 1 / A-414
1KING STUDIO ELEVATION A
Units x05, 307, 407, 507, x08, x27-x29, x31, x33-x34
1/2" = 1'-0" Reference: 1 / A-414
2KING STUDIO ELEVATION B
Units x05, 307, 407, 507, x08, x27-x29, x31, x33-x34
1/2" = 1'-0" Reference: 1 / A-414
3KING STUDIO ELEVATION C
Units x05, 307, 407, 507, x08, x27-x29, x31, x33-x34
1/2" = 1'-0" Reference: 1 / A-414
4KING STUDIO ELEVATION D
Units x05, 307, 407, 507, x08, x27-x29, x31, x33-x34
FFL
FFL
0'1' 2'4'
SCALE: 1/2" = 1'-0"
KEYNOTES - UNIT PLANS
1 ALIGN
2 GENERAL CONTRACTOR TO COORDINATE W/ FURNITUREFABRICATOR WHERE NECESSARY TO PROVIDE PROPERBLOCKING IN WALL FOR ITEM KEYNOTED
3 NO FINISHES UNDER THE SHOWER PAN / TUB
4 NO FINISHES UNDER MILLWORK CABINETRY
5 TV AND MOUNT NOT TO PROJECT MORE THAN 4" FROMWALL
6 MOTORIZED BLINDS. PROVIDE JUNCTION BOX BEHINDVALENCE FOR POWER CONNECTION AND PERMANENTLYINSTALLED SWITCH ON WALL TO CONTROL BLINDS.
7 SWITCH CONTROLLING UNDER CABINET LIGHTING ATKITCHEN TO BE GANGED WITH LIGHTING AT ENTRY
8 SWITCH CONTROLLING GARBAGE DISPOSAL-REFER TOHADG FOR ACCESSIBLE ROOM REQ'S.
9 DEDICATED CIRCUIT FOR GARBAGE DISPOSAL
10 MASTER SWITCH
11 DEDICATED CIRCUIT FOR INDUCTION COOKTOP
12 DEDICATED CIRCUIT FOR DISHWASHER
13 DEDICATED CIRCUIT FOR REFRIGERATOR
14 ELECTRIC VANITY MIRROR - HARDWIRE FIXTURE TO WALL-CONTRACTOR TO VERIFY JBOX TYPE TO ENSURE PROPERINSTALLATION AND BACKING FOR ITEM KEYNOTED
15 DOORBELL AND DOORBELL ON/OFF SWITCH(COMMUNICATION FEATURES ROOMS ONLY)SIGNAGE ASREQ'D.
16 PLACE TV OUTLETS AND CONNECTIONS ON WALL OUTSIDEAREA OF BRACKET AND CONCEALED FROM VIEW BY TV
17 DEDICATED CIRCUIT FOR WASHER/DRYER. DIRECT VENTTO EXTERIOR
FURNISHING SCHEDULE
GUESTROOM FURNISHINGS
GR-103 CHAIR - KITCHEN STOOL
GR-105 SOFA - SLEEP BETWEEN ARMS
GR-201 SCONCE - NIGHTSTAND
GR-203 PENDANT LIGHT - PRODUCTIVITY TABLE
GR-205 LAMP - FLOOR LAMP
GR-308 NIGHTSTAND - REGULAR
GR-312 TABLE - NESTING
GR-314 TABLE - PRODUCTIVITY TABLE (STUDIO)
GR-318 DRESSER - HIGHBOY
GR-321 CLOSET - KING STUDIO SUITE
GR-326 VANITY - STUDIO AND 1-BEDROOM SUITES
GR-400 STATIC DRAPARY PANELS
GR-403 ROLLER SHADE - GUESTROOMS (MANUAL,SHEER/BLACK-OUT, 8' W)
GR-412 VALENCE FOR 8' WINDOW
GR-503 ART- ENTRY
GR-504 ART- SLEEPING/LIVING
GR-505 WALL HOOK
GR-506 MIRROR - GUESTROOM FULL LENGTH
GR-508 MIRROR - GUESTROOM VANITY
GR-800 KITCHENETTE - 1-BEDROOM
GR-900 GUESTROOM REFRIGERATOR
GR-901 GUESTROOM DISHWASHER
GR-902 GUESTROOM COOKTOP - 2 BURNER
GR-904 GARBAGE DISPOSAL 1/3HP
GR-905 MICROWAVE- WITH RECIRCULATING HOOD
GR-906GR-911 TELEVISION & TELEVISION MOUNT
GR-907 CLOCK/RADIO
GR-908 TELEPHONE - GUESTROOM
GR-KS BED - KING (GR-301, 303, 600)
PLUMBING/MECHANICAL FIXTURES
PF-01 TOILET - GUESTROOM
PF-03 SHOWER BASE - 60" X 36" WITH LINEARDRAIN
PF-07 LAVATORY - UNDERMOUNT, 20" X 14"
PF-11 SHOWER HEAD - 2 IN 1
PF-13 SHOWER/TUB VALVE & CONTROL
PF-15 FAUCET - LAVATORY
PF-40 SINK - KITCHENETTE
PF-41 FAUCET - KITCHENETTE
TOILET ACCESSORIES
HD-01 DUAL TOILET PAPER HOLDER
HD-04 WALL-MOUNTED ROBE HOOK
HD-04.1 TOWEL BAR
HD-05.2 SLIDING SHOWER DOOR
HD-08 18" GRAB BAR
HD-16 BULK AMENITY DISPENSER ATSHOWERS/TUBS
HD-18 FOOT LEDGE FOR SHOWER
HD-18.1 SOAP SHELF
HD-21 BULK AMENITY DISPENSER AT LAVATORIES
FFL
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
Revision Schedule
Number Description Date
MMAATVTVTVSD
TVA-415B4
1
2
3
A-4242
XE1/2
D-G02
18' - 8"
D-G03A
GR-103
GR-105
GR-105
GR-KM
GR-901
GR-900
11' - 0 1/2"7' - 7 3/4"12' - 5 3/4"13' - 11 1/4"6' - 0"W-G
GR-400GR-400
GR-308
GR-201
GR-201
GR-908
GR-907
GR-308
GR-504
GR-906GR-911
GR-103
P3.2
GR-322
GR-902
GR-507
A-4243
BED 1 1
TABLE
1
1
1
4' - 6"4' - 6"6' - 10"1' - 5"1' - 0"5' - 1"1' - 5"GR-203
GR-203
PLAN ELEV
DUPLEX OUTLET
QUADPLEX OUTLET
GFCI OUTLET
CAT6, RJ45 INTERNET OUTLET
TELEPHONE OUTLET
WALL MOUNTED WIRELESS THERMOSTAT
POWER OUTLET WITH USB PORTS
CATV OUTLET
ELECTRICAL SWITCH
FLOOR OUTLET
POWER AND SIGNAL LEGEND:
POWER SUPPLY
CEILING FIXTURE LEGEND:
6" RECESSED CAN DOWNLIGHT
DECORATIVE FLUSH MOUNT LIGHT
PENDENT TYPE SPRINKLERS
SMOKE DETECTOR
EXHAUST FAN / GRILLE
LINEAR SURFACE MOUNTED CONTINUOUS LED SYSTEM W/ FIXED MOUNTING CLIPS & FROSTED LENS / 3 WATTS PER FOOT, MLV/FWD
ELECTRICAL OUTLET HEIGHTS (U.N.O)
TYPICAL OUTLET - 15" A.F.F
TYPICAL ACCESSIBLE WALL OUTLET - 18" A.F.F
BATHROOM VANITY OUTLET - 42" A.F.F
TYP. KITCHEN OUTLET - 42" A.F.F
ADA KITCHEN OUTLET - 46" A.F.F
ADA BATHROOM VANITY OUTLET - 44" A.F.F
ELECTRICAL SWITCH HEIGHTS (U.N.O)
SWITCH - 44" A.F.F
THERMOSTAT REMOTE - 48" A.F.F MAX TO TOP OF SWITCH
JUNCTION BOX
DOOR BELL HARDWIRED TO DOORBELL LIGHT - MOUNT @ 46" A.F.F TO CENTER OF BUTTON (FOR COMMUNICATIONS FEATURES ROOMS ONLY)
SD
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216UNIT PLAN - KINGSTUDIO ADA MOBILITY
A-415
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
1/2" = 1'-0"2KING STUIO ADA MOBILITY REFLECTED CEILING PLAN
Units 138, 238 (Roll-In), 338 (Tub)
1/2" = 1'-0" Reference: 1 / A-102
1KING STUDIO ADA MOBILITY CONSTRUCTION PLAN
Units 138, 238 (Roll-In), 338 (Tub)
0'1' 2'4'
SCALE: 1/2" = 1'-0"
2
5
2
2
2
KEYNOTES - UNIT PLANS
1 ALIGN
2 GENERAL CONTRACTOR TO COORDINATE W/ FURNITUREFABRICATOR WHERE NECESSARY TO PROVIDE PROPERBLOCKING IN WALL FOR ITEM KEYNOTED
3 NO FINISHES UNDER THE SHOWER PAN / TUB
4 NO FINISHES UNDER MILLWORK CABINETRY
5 TV AND MOUNT NOT TO PROJECT MORE THAN 4" FROMWALL
6 MOTORIZED BLINDS. PROVIDE JUNCTION BOX BEHINDVALENCE FOR POWER CONNECTION AND PERMANENTLYINSTALLED SWITCH ON WALL TO CONTROL BLINDS.
7 SWITCH CONTROLLING UNDER CABINET LIGHTING ATKITCHEN TO BE GANGED WITH LIGHTING AT ENTRY
8 SWITCH CONTROLLING GARBAGE DISPOSAL-REFER TOHADG FOR ACCESSIBLE ROOM REQ'S.
9 DEDICATED CIRCUIT FOR GARBAGE DISPOSAL
10 MASTER SWITCH
11 DEDICATED CIRCUIT FOR INDUCTION COOKTOP
12 DEDICATED CIRCUIT FOR DISHWASHER
13 DEDICATED CIRCUIT FOR REFRIGERATOR
14 ELECTRIC VANITY MIRROR - HARDWIRE FIXTURE TO WALL-CONTRACTOR TO VERIFY JBOX TYPE TO ENSURE PROPERINSTALLATION AND BACKING FOR ITEM KEYNOTED
15 DOORBELL AND DOORBELL ON/OFF SWITCH(COMMUNICATION FEATURES ROOMS ONLY)SIGNAGE ASREQ'D.
16 PLACE TV OUTLETS AND CONNECTIONS ON WALL OUTSIDEAREA OF BRACKET AND CONCEALED FROM VIEW BY TV
17 DEDICATED CIRCUIT FOR WASHER/DRYER. DIRECT VENTTO EXTERIOR
FURNISHING SCHEDULE
GUESTROOM FURNISHINGS
GR-103 CHAIR - KITCHEN STOOL
GR-105 SOFA - SLEEP BETWEEN ARMS
GR-201 SCONCE - NIGHTSTAND
GR-203 PENDANT LIGHT - PRODUCTIVITY TABLE
GR-205 LAMP - FLOOR LAMP
GR-308 NIGHTSTAND - REGULAR
GR-312 TABLE - NESTING
GR-314 TABLE - PRODUCTIVITY TABLE (STUDIO)
GR-322 CLOSET - ACCESSIBLE KING STUDIO SUITE
GR-327 VANITY - ACCESSIBLE SUITES
GR-328 BATH CADDY - ACCESSIBLE SUITES
GR-400 STATIC DRAPARY PANELS
GR-403 ROLLER SHADE - GUESTROOMS (MANUAL,SHEER/BLACK-OUT, 8' W)
GR-412 VALENCE FOR 8' WINDOW
GR-503 ART- ENTRY
GR-504 ART- SLEEPING/LIVING
GR-505 WALL HOOK
GR-507 MIRROR - ADA VANITY
GR-800 KITCHENETTE - 1-BEDROOM
GR-900 GUESTROOM REFRIGERATOR
GR-901 GUESTROOM DISHWASHER
GR-902 GUESTROOM COOKTOP - 2 BURNER
GR-906GR-911 TELEVISION & TELEVISION MOUNT
GR-907 CLOCK/RADIO
GR-908 TELEPHONE - GUESTROOM
GR-912 RECIRCULATING HOOD
GR-913 COUNTERTOP MICROWAVE
GR-KM BED - KING MOBILITY (GR-301, 304, 600, 602)
PUBLIC AREA FURNISHINGS
PA-502 ART - PUBLIC RESTROOM- WOMEN'S
PLUMBING/MECHANICAL FIXTURES
PF-01 TOILET - GUESTROOM
PF-04 SHOWER BASE - 60" X 36" ADA ROLL-INSHOWER WITH EDGE TRENCH DRAIN
PF-06 BATHTUB - 5' X 32" WITH SIDE LEDGE
PF-07 LAVATORY - UNDERMOUNT, 20" X 14"
PF-10 SHOWER HEAD - HIGH
PF-12 SHOWER HEAD - HAND HELD ON SLIDE BAR
PF-13 SHOWER/TUB VALVE & CONTROL
PF-14 BATHTUB FILL FAUCET
PF-15 FAUCET - LAVATORY
PF-40 SINK - KITCHENETTE
PF-41 FAUCET - KITCHENETTE
PF-42 SINK - ADA KITCHENETTE
TOILET ACCESSORIES
HD-02 DUAL TOILET PAPER HOLDER- ADA
HD-04 WALL-MOUNTED ROBE HOOK
HD-04.1 TOWEL BAR
HD-05 CURVED CURTAIN ROD AND SHOWERCURTAIN
HD-08 18" GRAB BAR
HD-09 24" GRAB BAR
HD-10 42" GRAB BAR AT ADA BATHTUB
HD-11 36" GRAB BAR
HD-11.1 42" GRAB BAR
HD-12 DOOR-MOUNTED ROBE HOOK
HD-14.1 ROLL-IN SHOWER SEAT
HD-16 BULK AMENITY DISPENSER ATSHOWERS/TUBS
HD-18.1 SOAP SHELF
HD-20 12" GRAB BAR
HD-21 BULK AMENITY DISPENSER AT LAVATORIES
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
Revision Schedule
Number Description Date
TVTVTVA-415B4
1
2
3
A-4246
5
4
CPT-10
SF-01
WC-01
WC-01
WC-01
WC-01
WC-01
1
A-510
Sim
6
A-510
Sim
9
A-510
Sim
7
A-510
Sim
9' - 6 3/4"
RES-01
CPT-01
CT-01
PLAN ELEV
DUPLEX OUTLET
QUADPLEX OUTLET
GFCI OUTLET
CAT6, RJ45 INTERNET OUTLET
TELEPHONE OUTLET
WALL MOUNTED WIRELESS THERMOSTAT
POWER OUTLET WITH USB PORTS
CATV OUTLET
ELECTRICAL SWITCH
FLOOR OUTLET
POWER AND SIGNAL LEGEND:
POWER SUPPLY
CEILING FIXTURE LEGEND:
6" RECESSED CAN DOWNLIGHT
DECORATIVE FLUSH MOUNT LIGHT
PENDENT TYPE SPRINKLERS
SMOKE DETECTOR
EXHAUST FAN / GRILLE
LINEAR SURFACE MOUNTED CONTINUOUS LED SYSTEM W/ FIXED MOUNTING CLIPS & FROSTED LENS / 3 WATTS PER FOOT, MLV/FWD
ELECTRICAL OUTLET HEIGHTS (U.N.O)
TYPICAL OUTLET - 15" A.F.F
TYPICAL ACCESSIBLE WALL OUTLET - 18" A.F.F
BATHROOM VANITY OUTLET - 42" A.F.F
TYP. KITCHEN OUTLET - 42" A.F.F
ADA KITCHEN OUTLET - 46" A.F.F
ADA BATHROOM VANITY OUTLET - 44" A.F.F
ELECTRICAL SWITCH HEIGHTS (U.N.O)
SWITCH - 44" A.F.F
THERMOSTAT REMOTE - 48" A.F.F MAX TO TOP OF SWITCH
JUNCTION BOX
DOOR BELL HARDWIRED TO DOORBELL LIGHT - MOUNT @ 46" A.F.F TO CENTER OF BUTTON (FOR COMMUNICATIONS FEATURES ROOMS ONLY)
SD
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216UNIT PLAN - KINGSTUDIO ADA MOBILITY -ELEC, DATA & FLOORFINISH PLAN
A-415A
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
1/2" = 1'-0"2KING STUIO ADA MOBILITY ELECTRICAL & DATA PLAN
Units 138, 238, 338 1/2" = 1'-0"1KING STUIO ADA MOBILITY FLOOR & WALL PLAN
Units 138, 238, 338
0'1' 2'4'
SCALE: 1/2" = 1'-0"
3
15
12
8
9
11
13
7
10
16
14
KEYNOTES - UNIT PLANS
1 ALIGN
2 GENERAL CONTRACTOR TO COORDINATE W/ FURNITUREFABRICATOR WHERE NECESSARY TO PROVIDE PROPERBLOCKING IN WALL FOR ITEM KEYNOTED
3 NO FINISHES UNDER THE SHOWER PAN / TUB
4 NO FINISHES UNDER MILLWORK CABINETRY
5 TV AND MOUNT NOT TO PROJECT MORE THAN 4" FROMWALL
6 MOTORIZED BLINDS. PROVIDE JUNCTION BOX BEHINDVALENCE FOR POWER CONNECTION AND PERMANENTLYINSTALLED SWITCH ON WALL TO CONTROL BLINDS.
7 SWITCH CONTROLLING UNDER CABINET LIGHTING ATKITCHEN TO BE GANGED WITH LIGHTING AT ENTRY
8 SWITCH CONTROLLING GARBAGE DISPOSAL-REFER TOHADG FOR ACCESSIBLE ROOM REQ'S.
9 DEDICATED CIRCUIT FOR GARBAGE DISPOSAL
10 MASTER SWITCH
11 DEDICATED CIRCUIT FOR INDUCTION COOKTOP
12 DEDICATED CIRCUIT FOR DISHWASHER
13 DEDICATED CIRCUIT FOR REFRIGERATOR
14 ELECTRIC VANITY MIRROR - HARDWIRE FIXTURE TO WALL-CONTRACTOR TO VERIFY JBOX TYPE TO ENSURE PROPERINSTALLATION AND BACKING FOR ITEM KEYNOTED
15 DOORBELL AND DOORBELL ON/OFF SWITCH(COMMUNICATION FEATURES ROOMS ONLY)SIGNAGE ASREQ'D.
16 PLACE TV OUTLETS AND CONNECTIONS ON WALL OUTSIDEAREA OF BRACKET AND CONCEALED FROM VIEW BY TV
17 DEDICATED CIRCUIT FOR WASHER/DRYER. DIRECT VENTTO EXTERIOR
FURNISHING SCHEDULE
GUESTROOM FURNISHINGS
GR-103 CHAIR - KITCHEN STOOL
GR-105 SOFA - SLEEP BETWEEN ARMS
GR-201 SCONCE - NIGHTSTAND
GR-205 LAMP - FLOOR LAMP
GR-308 NIGHTSTAND - REGULAR
GR-312 TABLE - NESTING
GR-314 TABLE - PRODUCTIVITY TABLE (STUDIO)
GR-322 CLOSET - ACCESSIBLE KING STUDIO SUITE
GR-327 VANITY - ACCESSIBLE SUITES
GR-328 BATH CADDY - ACCESSIBLE SUITES
GR-400 STATIC DRAPARY PANELS
GR-503 ART- ENTRY
GR-504 ART- SLEEPING/LIVING
GR-507 MIRROR - ADA VANITY
GR-800 KITCHENETTE - 1-BEDROOM
GR-900 GUESTROOM REFRIGERATOR
GR-901 GUESTROOM DISHWASHER
GR-902 GUESTROOM COOKTOP - 2 BURNER
GR-906GR-911 TELEVISION & TELEVISION MOUNT
GR-907 CLOCK/RADIO
GR-908 TELEPHONE - GUESTROOM
GR-913 COUNTERTOP MICROWAVE
GR-KM BED - KING MOBILITY (GR-301, 304, 600, 602)
PLUMBING/MECHANICAL FIXTURES
PF-01 TOILET - GUESTROOM
PF-06 BATHTUB - 5' X 32" WITH SIDE LEDGE
PF-07 LAVATORY - UNDERMOUNT, 20" X 14"
PF-12 SHOWER HEAD - HAND HELD ON SLIDE BAR
PF-13 SHOWER/TUB VALVE & CONTROL
PF-14 BATHTUB FILL FAUCET
PF-15 FAUCET - LAVATORY
PF-42 SINK - ADA KITCHENETTE
TOILET ACCESSORIES
HD-02 DUAL TOILET PAPER HOLDER- ADA
HD-04 WALL-MOUNTED ROBE HOOK
HD-04.1 TOWEL BAR
HD-08 18" GRAB BAR
HD-09 24" GRAB BAR
HD-10 42" GRAB BAR AT ADA BATHTUB
HD-11 36" GRAB BAR
HD-11.1 42" GRAB BAR
HD-14.1 ROLL-IN SHOWER SEAT
HD-16 BULK AMENITY DISPENSER ATSHOWERS/TUBS
HD-18.1 SOAP SHELF
HD-20 12" GRAB BAR
HD-21 BULK AMENITY DISPENSER AT LAVATORIES
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
Revision Schedule
Number Description Date
TV5' - 0"GR-505
5' - 0"RB-01
WC-01
WD-01
WC-02
PT-03PL-02
WC-01
RB-01
EQ
RB-01
EQ
6
GR-KM
PA-502
D-G03AGR-322
1' - 1 1/2"1' - 6"
WC-01
17
A-510
Sim
RB-015' - 0"W-G
GR-412
6' - 1 1/4"5' - 1"0' - 3"
RB-01
WC-01
PT-03PL-024' - 2"WC-01
GFCI
WC-01
D-G02
PLAN ELEV
DUPLEX OUTLET
QUADPLEX OUTLET
GFCI OUTLET
CAT6, RJ45 INTERNET OUTLET
TELEPHONE OUTLET
WALL MOUNTED WIRELESS THERMOSTAT
POWER OUTLET WITH USB PORTS
CATV OUTLET
ELECTRICAL SWITCH
FLOOR OUTLET
POWER AND SIGNAL LEGEND:
POWER SUPPLY
CEILING FIXTURE LEGEND:
6" RECESSED CAN DOWNLIGHT
DECORATIVE FLUSH MOUNT LIGHT
PENDENT TYPE SPRINKLERS
SMOKE DETECTOR
EXHAUST FAN / GRILLE
LINEAR SURFACE MOUNTED CONTINUOUS LED SYSTEM W/ FIXED MOUNTING CLIPS & FROSTED LENS / 3 WATTS PER FOOT, MLV/FWD
ELECTRICAL OUTLET HEIGHTS (U.N.O)
TYPICAL OUTLET - 15" A.F.F
TYPICAL ACCESSIBLE WALL OUTLET - 18" A.F.F
BATHROOM VANITY OUTLET - 42" A.F.F
TYP. KITCHEN OUTLET - 42" A.F.F
ADA KITCHEN OUTLET - 46" A.F.F
ADA BATHROOM VANITY OUTLET - 44" A.F.F
ELECTRICAL SWITCH HEIGHTS (U.N.O)
SWITCH - 44" A.F.F
THERMOSTAT REMOTE - 48" A.F.F MAX TO TOP OF SWITCH
JUNCTION BOX
DOOR BELL HARDWIRED TO DOORBELL LIGHT - MOUNT @ 46" A.F.F TO CENTER OF BUTTON (FOR COMMUNICATIONS FEATURES ROOMS ONLY)
SD
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216UNIT INT. ELEVATIONS -KING STUDIO ADAMOBILITY
A-415B
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
FFL
FFL
1/2" = 1'-0" Reference: 1 / A-415
1KING STUIO ADA MOBILITY ELEVATION A
Units 138, 238, 338
1/2" = 1'-0" Reference: 1 / A-415
2KING STUIO ADA MOBILITY ELEVATION B
Units 138, 238, 338
1/2" = 1'-0" Reference: 1 / A-415
3KING STUIO ADA MOBILITY ELEVATION C
Units 138, 238, 338
1/2" = 1'-0" Reference: 1 / A-415
4KING STUIO ADA MOBILITY ELEVATION D
Units 138, 238, 338 0'1' 2'4'
SCALE: 1/2" = 1'-0"
FFL
KEYNOTES - UNIT PLANS
1 ALIGN
2 GENERAL CONTRACTOR TO COORDINATE W/ FURNITUREFABRICATOR WHERE NECESSARY TO PROVIDE PROPERBLOCKING IN WALL FOR ITEM KEYNOTED
3 NO FINISHES UNDER THE SHOWER PAN / TUB
4 NO FINISHES UNDER MILLWORK CABINETRY
5 TV AND MOUNT NOT TO PROJECT MORE THAN 4" FROMWALL
6 MOTORIZED BLINDS. PROVIDE JUNCTION BOX BEHINDVALENCE FOR POWER CONNECTION AND PERMANENTLYINSTALLED SWITCH ON WALL TO CONTROL BLINDS.
7 SWITCH CONTROLLING UNDER CABINET LIGHTING ATKITCHEN TO BE GANGED WITH LIGHTING AT ENTRY
8 SWITCH CONTROLLING GARBAGE DISPOSAL-REFER TOHADG FOR ACCESSIBLE ROOM REQ'S.
9 DEDICATED CIRCUIT FOR GARBAGE DISPOSAL
10 MASTER SWITCH
11 DEDICATED CIRCUIT FOR INDUCTION COOKTOP
12 DEDICATED CIRCUIT FOR DISHWASHER
13 DEDICATED CIRCUIT FOR REFRIGERATOR
14 ELECTRIC VANITY MIRROR - HARDWIRE FIXTURE TO WALL-CONTRACTOR TO VERIFY JBOX TYPE TO ENSURE PROPERINSTALLATION AND BACKING FOR ITEM KEYNOTED
15 DOORBELL AND DOORBELL ON/OFF SWITCH(COMMUNICATION FEATURES ROOMS ONLY)SIGNAGE ASREQ'D.
16 PLACE TV OUTLETS AND CONNECTIONS ON WALL OUTSIDEAREA OF BRACKET AND CONCEALED FROM VIEW BY TV
17 DEDICATED CIRCUIT FOR WASHER/DRYER. DIRECT VENTTO EXTERIOR
FURNISHING SCHEDULE
GUESTROOM FURNISHINGS
GR-103 CHAIR - KITCHEN STOOL
GR-105 SOFA - SLEEP BETWEEN ARMS
GR-201 SCONCE - NIGHTSTAND
GR-203 PENDANT LIGHT - PRODUCTIVITY TABLE
GR-205 LAMP - FLOOR LAMP
GR-308 NIGHTSTAND - REGULAR
GR-312 TABLE - NESTING
GR-313 TABLE - ROUND SIDE TABLE
GR-314 TABLE - PRODUCTIVITY TABLE (STUDIO)
GR-321 CLOSET - KING STUDIO SUITE
GR-322 CLOSET - ACCESSIBLE KING STUDIO SUITE
GR-327 VANITY - ACCESSIBLE SUITES
GR-328 BATH CADDY - ACCESSIBLE SUITES
GR-400 STATIC DRAPARY PANELS
GR-403 ROLLER SHADE - GUESTROOMS (MANUAL,SHEER/BLACK-OUT, 8' W)
GR-412 VALENCE FOR 8' WINDOW
GR-503 ART- ENTRY
GR-504 ART- SLEEPING/LIVING
GR-505 WALL HOOK
GR-507 MIRROR - ADA VANITY
GR-800 KITCHENETTE - 1-BEDROOM
GR-900 GUESTROOM REFRIGERATOR
GR-901 GUESTROOM DISHWASHER
GR-902 GUESTROOM COOKTOP - 2 BURNER
GR-904 GARBAGE DISPOSAL 1/3HP
GR-905 MICROWAVE- WITH RECIRCULATING HOOD
GR-906GR-911 TELEVISION & TELEVISION MOUNT
GR-907 CLOCK/RADIO
GR-908 TELEPHONE - GUESTROOM
GR-912 RECIRCULATING HOOD
GR-913 COUNTERTOP MICROWAVE
GR-KM BED - KING MOBILITY (GR-301, 304, 600, 602)
PUBLIC AREA FURNISHINGS
PA-502 ART - PUBLIC RESTROOM- WOMEN'S
OWNER SPECIFIED - OWNER FURNISHED
OP-706 FIRE EXTINGUISHER CABINET
PLUMBING/MECHANICAL FIXTURES
PF-01 TOILET - GUESTROOM
PF-03 SHOWER BASE - 60" X 36" WITH LINEARDRAIN
PF-06 BATHTUB - 5' X 32" WITH SIDE LEDGE
PF-07 LAVATORY - UNDERMOUNT, 20" X 14"
PF-10 SHOWER HEAD - HIGH
PF-11 SHOWER HEAD - 2 IN 1
PF-12 SHOWER HEAD - HAND HELD ON SLIDE BAR
PF-13 SHOWER/TUB VALVE & CONTROL
PF-14 BATHTUB FILL FAUCET
PF-15 FAUCET - LAVATORY
PF-40 SINK - KITCHENETTE
PF-41 FAUCET - KITCHENETTE
PF-42 SINK - ADA KITCHENETTE
TOILET ACCESSORIES
HD-02 DUAL TOILET PAPER HOLDER- ADA
HD-04 WALL-MOUNTED ROBE HOOK
HD-04.1 TOWEL BAR
HD-05 CURVED CURTAIN ROD AND SHOWERCURTAIN
HD-05.2 SLIDING SHOWER DOOR
HD-08 18" GRAB BAR
HD-09 24" GRAB BAR
HD-10 42" GRAB BAR AT ADA BATHTUB
HD-11 36" GRAB BAR
HD-11.1 42" GRAB BAR
HD-12 DOOR-MOUNTED ROBE HOOK
HD-14.1 ROLL-IN SHOWER SEAT
HD-16 BULK AMENITY DISPENSER ATSHOWERS/TUBS
HD-18 FOOT LEDGE FOR SHOWER
HD-18.1 SOAP SHELF
HD-20 12" GRAB BAR
HD-21 BULK AMENITY DISPENSER AT LAVATORIES
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
Revision Schedule
Number Description Date
MMAATVTVSD
TV
A-416B4
1
2
3
XE1/2
XE1/2
XE1/2
P3.2
4' - 6"
D-G01
12' - 2 1/4"6' - 5 3/4"6' - 5 1/4"5' - 3 1/2"14' - 8 1/4"6' - 0"
W-G
D-G02
18' - 8"26' - 2"GR-400GR-400
GR-308
GR-201
GR-907
GR-908
GR-308GR-201
GR-504
GR-105GR-312
GR-205
GR-103
GR-103
GR-318
GR-321
GR-906GR-911
GR-506
4' - 6"4' - 6"
CL-B8' - 0"
CL-B27' - 6"
CL-A8' - 0"
OF BED
EQ EQ
OF TABLE
1' - 6"1' - 5"1' - 5"2' - 8"
1
1
1
114' - 0"CL-B27' - 6"
PLAN ELEV
DUPLEX OUTLET
QUADPLEX OUTLET
GFCI OUTLET
CAT6, RJ45 INTERNET OUTLET
TELEPHONE OUTLET
WALL MOUNTED WIRELESS THERMOSTAT
POWER OUTLET WITH USB PORTS
CATV OUTLET
ELECTRICAL SWITCH
FLOOR OUTLET
POWER AND SIGNAL LEGEND:
POWER SUPPLY
CEILING FIXTURE LEGEND:
6" RECESSED CAN DOWNLIGHT
DECORATIVE FLUSH MOUNT LIGHT
PENDENT TYPE SPRINKLERS
SMOKE DETECTOR
EXHAUST FAN / GRILLE
LINEAR SURFACE MOUNTED CONTINUOUS LED SYSTEM W/ FIXED MOUNTING CLIPS & FROSTED LENS / 3 WATTS PER FOOT, MLV/FWD
ELECTRICAL OUTLET HEIGHTS (U.N.O)
TYPICAL OUTLET - 15" A.F.F
TYPICAL ACCESSIBLE WALL OUTLET - 18" A.F.F
BATHROOM VANITY OUTLET - 42" A.F.F
TYP. KITCHEN OUTLET - 42" A.F.F
ADA KITCHEN OUTLET - 46" A.F.F
ADA BATHROOM VANITY OUTLET - 44" A.F.F
ELECTRICAL SWITCH HEIGHTS (U.N.O)
SWITCH - 44" A.F.F
THERMOSTAT REMOTE - 48" A.F.F MAX TO TOP OF SWITCH
JUNCTION BOX
DOOR BELL HARDWIRED TO DOORBELL LIGHT - MOUNT @ 46" A.F.F TO CENTER OF BUTTON (FOR COMMUNICATIONS FEATURES ROOMS ONLY)
SD
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216UNIT PLAN - KINGSTUDIO ENLARGED
A-416
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
1/2" = 1'-0" Reference: 1 / A-104
1KING STUDIO ENLARGED UNIT CONSTRUCTION PLAN
Units 438, 538
1/2" = 1'-0" Reference: 1 / x-114
2KING STUDIO ENLARGED UNIT REFLECTED CEILING PLAN
Units 438, 538
0'1' 2'4'
SCALE: 1/2" = 1'-0"
KEYNOTES - UNIT PLANS
1 ALIGN
2 GENERAL CONTRACTOR TO COORDINATE W/ FURNITUREFABRICATOR WHERE NECESSARY TO PROVIDE PROPERBLOCKING IN WALL FOR ITEM KEYNOTED
3 NO FINISHES UNDER THE SHOWER PAN / TUB
4 NO FINISHES UNDER MILLWORK CABINETRY
5 TV AND MOUNT NOT TO PROJECT MORE THAN 4" FROMWALL
6 MOTORIZED BLINDS. PROVIDE JUNCTION BOX BEHINDVALENCE FOR POWER CONNECTION AND PERMANENTLYINSTALLED SWITCH ON WALL TO CONTROL BLINDS.
7 SWITCH CONTROLLING UNDER CABINET LIGHTING ATKITCHEN TO BE GANGED WITH LIGHTING AT ENTRY
8 SWITCH CONTROLLING GARBAGE DISPOSAL-REFER TOHADG FOR ACCESSIBLE ROOM REQ'S.
9 DEDICATED CIRCUIT FOR GARBAGE DISPOSAL
10 MASTER SWITCH
11 DEDICATED CIRCUIT FOR INDUCTION COOKTOP
12 DEDICATED CIRCUIT FOR DISHWASHER
13 DEDICATED CIRCUIT FOR REFRIGERATOR
14 ELECTRIC VANITY MIRROR - HARDWIRE FIXTURE TO WALL-CONTRACTOR TO VERIFY JBOX TYPE TO ENSURE PROPERINSTALLATION AND BACKING FOR ITEM KEYNOTED
15 DOORBELL AND DOORBELL ON/OFF SWITCH(COMMUNICATION FEATURES ROOMS ONLY)SIGNAGE ASREQ'D.
16 PLACE TV OUTLETS AND CONNECTIONS ON WALL OUTSIDEAREA OF BRACKET AND CONCEALED FROM VIEW BY TV
17 DEDICATED CIRCUIT FOR WASHER/DRYER. DIRECT VENTTO EXTERIOR
2
5
2
2
2
FURNISHING SCHEDULE
GUESTROOM FURNISHINGS
GR-103 CHAIR - KITCHEN STOOL
GR-105 SOFA - SLEEP BETWEEN ARMS
GR-201 SCONCE - NIGHTSTAND
GR-203 PENDANT LIGHT - PRODUCTIVITY TABLE
GR-205 LAMP - FLOOR LAMP
GR-308 NIGHTSTAND - REGULAR
GR-312 TABLE - NESTING
GR-314 TABLE - PRODUCTIVITY TABLE (STUDIO)
GR-318 DRESSER - HIGHBOY
GR-321 CLOSET - KING STUDIO SUITE
GR-326 VANITY - STUDIO AND 1-BEDROOM SUITES
GR-400 STATIC DRAPARY PANELS
GR-403 ROLLER SHADE - GUESTROOMS (MANUAL,SHEER/BLACK-OUT, 8' W)
GR-412 VALENCE FOR 8' WINDOW
GR-503 ART- ENTRY
GR-504 ART- SLEEPING/LIVING
GR-506 MIRROR - GUESTROOM FULL LENGTH
GR-800 KITCHENETTE - 1-BEDROOM
GR-900 GUESTROOM REFRIGERATOR
GR-901 GUESTROOM DISHWASHER
GR-902 GUESTROOM COOKTOP - 2 BURNER
GR-904 GARBAGE DISPOSAL 1/3HP
GR-905 MICROWAVE- WITH RECIRCULATING HOOD
GR-906GR-911 TELEVISION & TELEVISION MOUNT
GR-907 CLOCK/RADIO
GR-908 TELEPHONE - GUESTROOM
GR-KS BED - KING (GR-301, 303, 600)
PLUMBING/MECHANICAL FIXTURES
PF-01 TOILET - GUESTROOM
PF-03 SHOWER BASE - 60" X 36" WITH LINEARDRAIN
PF-07 LAVATORY - UNDERMOUNT, 20" X 14"
PF-11 SHOWER HEAD - 2 IN 1
PF-13 SHOWER/TUB VALVE & CONTROL
PF-15 FAUCET - LAVATORY
PF-40 SINK - KITCHENETTE
PF-41 FAUCET - KITCHENETTE
TOILET ACCESSORIES
HD-01 DUAL TOILET PAPER HOLDER
HD-04 WALL-MOUNTED ROBE HOOK
HD-04.1 TOWEL BAR
HD-05.2 SLIDING SHOWER DOOR
HD-08 18" GRAB BAR
HD-16 BULK AMENITY DISPENSER ATSHOWERS/TUBS
HD-18 FOOT LEDGE FOR SHOWER
HD-18.1 SOAP SHELF
HD-21 BULK AMENITY DISPENSER AT LAVATORIES
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
Revision Schedule
Number Description Date
TVTVTV
A-416B4
1
2
3
SF-01
WC-01
WC-01
WC-01
WC-01
WC-01
CPT-10
RES-01
CPT-01
CT-01
6
A-510
Sim
7
A-510
Sim FULL TILEFULL TILE
9
A-510
Sim
1
A-510
Sim
FULL TILE
PLAN ELEV
DUPLEX OUTLET
QUADPLEX OUTLET
GFCI OUTLET
CAT6, RJ45 INTERNET OUTLET
TELEPHONE OUTLET
WALL MOUNTED WIRELESS THERMOSTAT
POWER OUTLET WITH USB PORTS
CATV OUTLET
ELECTRICAL SWITCH
FLOOR OUTLET
POWER AND SIGNAL LEGEND:
POWER SUPPLY
CEILING FIXTURE LEGEND:
6" RECESSED CAN DOWNLIGHT
DECORATIVE FLUSH MOUNT LIGHT
PENDENT TYPE SPRINKLERS
SMOKE DETECTOR
EXHAUST FAN / GRILLE
LINEAR SURFACE MOUNTED CONTINUOUS LED SYSTEM W/ FIXED MOUNTING CLIPS & FROSTED LENS / 3 WATTS PER FOOT, MLV/FWD
ELECTRICAL OUTLET HEIGHTS (U.N.O)
TYPICAL OUTLET - 15" A.F.F
TYPICAL ACCESSIBLE WALL OUTLET - 18" A.F.F
BATHROOM VANITY OUTLET - 42" A.F.F
TYP. KITCHEN OUTLET - 42" A.F.F
ADA KITCHEN OUTLET - 46" A.F.F
ADA BATHROOM VANITY OUTLET - 44" A.F.F
ELECTRICAL SWITCH HEIGHTS (U.N.O)
SWITCH - 44" A.F.F
THERMOSTAT REMOTE - 48" A.F.F MAX TO TOP OF SWITCH
JUNCTION BOX
DOOR BELL HARDWIRED TO DOORBELL LIGHT - MOUNT @ 46" A.F.F TO CENTER OF BUTTON (FOR COMMUNICATIONS FEATURES ROOMS ONLY)
SD
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216UNIT PLAN - KINGSTUDIO ENLARGED -ELEC, DATA & FLOORFINISH PLAN
A-416A
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
1/2" = 1'-0"1KING STUDIO ENLARGED UNIT ELECTRICAL & DATA PLAN
Units 438, 538
1/2" = 1'-0"2KING STUDIO ENLARGED UNIT FLOOR & WALL FINISH PLAN
Units 438, 538
0'1' 2'4'
SCALE: 1/2" = 1'-0"
3
15
12
8
9
11
13
7
10
16
14
KEYNOTES - UNIT PLANS
1 ALIGN
2 GENERAL CONTRACTOR TO COORDINATE W/ FURNITUREFABRICATOR WHERE NECESSARY TO PROVIDE PROPERBLOCKING IN WALL FOR ITEM KEYNOTED
3 NO FINISHES UNDER THE SHOWER PAN / TUB
4 NO FINISHES UNDER MILLWORK CABINETRY
5 TV AND MOUNT NOT TO PROJECT MORE THAN 4" FROMWALL
6 MOTORIZED BLINDS. PROVIDE JUNCTION BOX BEHINDVALENCE FOR POWER CONNECTION AND PERMANENTLYINSTALLED SWITCH ON WALL TO CONTROL BLINDS.
7 SWITCH CONTROLLING UNDER CABINET LIGHTING ATKITCHEN TO BE GANGED WITH LIGHTING AT ENTRY
8 SWITCH CONTROLLING GARBAGE DISPOSAL-REFER TOHADG FOR ACCESSIBLE ROOM REQ'S.
9 DEDICATED CIRCUIT FOR GARBAGE DISPOSAL
10 MASTER SWITCH
11 DEDICATED CIRCUIT FOR INDUCTION COOKTOP
12 DEDICATED CIRCUIT FOR DISHWASHER
13 DEDICATED CIRCUIT FOR REFRIGERATOR
14 ELECTRIC VANITY MIRROR - HARDWIRE FIXTURE TO WALL-CONTRACTOR TO VERIFY JBOX TYPE TO ENSURE PROPERINSTALLATION AND BACKING FOR ITEM KEYNOTED
15 DOORBELL AND DOORBELL ON/OFF SWITCH(COMMUNICATION FEATURES ROOMS ONLY)SIGNAGE ASREQ'D.
16 PLACE TV OUTLETS AND CONNECTIONS ON WALL OUTSIDEAREA OF BRACKET AND CONCEALED FROM VIEW BY TV
17 DEDICATED CIRCUIT FOR WASHER/DRYER. DIRECT VENTTO EXTERIOR
FURNISHING SCHEDULE
GUESTROOM FURNISHINGS
GR-103 CHAIR - KITCHEN STOOL
GR-105 SOFA - SLEEP BETWEEN ARMS
GR-201 SCONCE - NIGHTSTAND
GR-205 LAMP - FLOOR LAMP
GR-308 NIGHTSTAND - REGULAR
GR-312 TABLE - NESTING
GR-314 TABLE - PRODUCTIVITY TABLE (STUDIO)
GR-318 DRESSER - HIGHBOY
GR-321 CLOSET - KING STUDIO SUITE
GR-326 VANITY - STUDIO AND 1-BEDROOM SUITES
GR-400 STATIC DRAPARY PANELS
GR-504 ART- SLEEPING/LIVING
GR-506 MIRROR - GUESTROOM FULL LENGTH
GR-800 KITCHENETTE - 1-BEDROOM
GR-900 GUESTROOM REFRIGERATOR
GR-901 GUESTROOM DISHWASHER
GR-902 GUESTROOM COOKTOP - 2 BURNER
GR-904 GARBAGE DISPOSAL 1/3HP
GR-906GR-911 TELEVISION & TELEVISION MOUNT
GR-907 CLOCK/RADIO
GR-908 TELEPHONE - GUESTROOM
GR-KS BED - KING (GR-301, 303, 600)
PLUMBING/MECHANICAL FIXTURES
PF-01 TOILET - GUESTROOM
PF-03 SHOWER BASE - 60" X 36" WITH LINEARDRAIN
PF-07 LAVATORY - UNDERMOUNT, 20" X 14"
PF-11 SHOWER HEAD - 2 IN 1
PF-13 SHOWER/TUB VALVE & CONTROL
PF-15 FAUCET - LAVATORY
PF-40 SINK - KITCHENETTE
PF-41 FAUCET - KITCHENETTE
TOILET ACCESSORIES
HD-01 DUAL TOILET PAPER HOLDER
HD-04.1 TOWEL BAR
HD-05.2 SLIDING SHOWER DOOR
HD-08 18" GRAB BAR
HD-16 BULK AMENITY DISPENSER ATSHOWERS/TUBS
HD-18 FOOT LEDGE FOR SHOWER
HD-18.1 SOAP SHELF
HD-21 BULK AMENITY DISPENSER AT LAVATORIES
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
Revision Schedule
Number Description Date
TV5' - 0"2' - 3"
RB-01
WC-01
PT-11PL-01
WC-01
5' - 2"2' - 2"
RB-01
WC-01
RB-01
PL-02PT-03
D-G03
GR-503
GR-KS
GR-318
SF-01
GR-412
W-G
16
A-510
Sim
RB-01
GR-403
GR-400
4' - 2"3' - 5 1/2"
0' - 3"5' - 1"RB-01
WC-01
PT-03PL-02
WC-01
D-G02
PLAN ELEV
DUPLEX OUTLET
QUADPLEX OUTLET
GFCI OUTLET
CAT6, RJ45 INTERNET OUTLET
TELEPHONE OUTLET
WALL MOUNTED WIRELESS THERMOSTAT
POWER OUTLET WITH USB PORTS
CATV OUTLET
ELECTRICAL SWITCH
FLOOR OUTLET
POWER AND SIGNAL LEGEND:
POWER SUPPLY
CEILING FIXTURE LEGEND:
6" RECESSED CAN DOWNLIGHT
DECORATIVE FLUSH MOUNT LIGHT
PENDENT TYPE SPRINKLERS
SMOKE DETECTOR
EXHAUST FAN / GRILLE
LINEAR SURFACE MOUNTED CONTINUOUS LED SYSTEM W/ FIXED MOUNTING CLIPS & FROSTED LENS / 3 WATTS PER FOOT, MLV/FWD
ELECTRICAL OUTLET HEIGHTS (U.N.O)
TYPICAL OUTLET - 15" A.F.F
TYPICAL ACCESSIBLE WALL OUTLET - 18" A.F.F
BATHROOM VANITY OUTLET - 42" A.F.F
TYP. KITCHEN OUTLET - 42" A.F.F
ADA KITCHEN OUTLET - 46" A.F.F
ADA BATHROOM VANITY OUTLET - 44" A.F.F
ELECTRICAL SWITCH HEIGHTS (U.N.O)
SWITCH - 44" A.F.F
THERMOSTAT REMOTE - 48" A.F.F MAX TO TOP OF SWITCH
JUNCTION BOX
DOOR BELL HARDWIRED TO DOORBELL LIGHT - MOUNT @ 46" A.F.F TO CENTER OF BUTTON (FOR COMMUNICATIONS FEATURES ROOMS ONLY)
SD
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216UNIT INT. ELEVATIONS -KING STUDIOENLARGED
A-416B
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
FFL
FFL
1/2" = 1'-0" Reference: 1 / A-416
1KING STUDIO ENLARGED ELEVATION A
Units 438, 538
1/2" = 1'-0" Reference: 1 / A-416
2KING STUDIO ENLARGED ELEVATION B
Units 438, 538
1/2" = 1'-0" Reference: 1 / A-416
3KING STUDIO ENLARGED ELEVATION C
Units 438, 538
1/2" = 1'-0" Reference: 1 / A-416
4KING STUDIO ENLARGED ELEVATION D
Units 438, 538
FFL
KEYNOTES - UNIT PLANS
1 ALIGN
2 GENERAL CONTRACTOR TO COORDINATE W/ FURNITUREFABRICATOR WHERE NECESSARY TO PROVIDE PROPERBLOCKING IN WALL FOR ITEM KEYNOTED
3 NO FINISHES UNDER THE SHOWER PAN / TUB
4 NO FINISHES UNDER MILLWORK CABINETRY
5 TV AND MOUNT NOT TO PROJECT MORE THAN 4" FROMWALL
6 MOTORIZED BLINDS. PROVIDE JUNCTION BOX BEHINDVALENCE FOR POWER CONNECTION AND PERMANENTLYINSTALLED SWITCH ON WALL TO CONTROL BLINDS.
7 SWITCH CONTROLLING UNDER CABINET LIGHTING ATKITCHEN TO BE GANGED WITH LIGHTING AT ENTRY
8 SWITCH CONTROLLING GARBAGE DISPOSAL-REFER TOHADG FOR ACCESSIBLE ROOM REQ'S.
9 DEDICATED CIRCUIT FOR GARBAGE DISPOSAL
10 MASTER SWITCH
11 DEDICATED CIRCUIT FOR INDUCTION COOKTOP
12 DEDICATED CIRCUIT FOR DISHWASHER
13 DEDICATED CIRCUIT FOR REFRIGERATOR
14 ELECTRIC VANITY MIRROR - HARDWIRE FIXTURE TO WALL-CONTRACTOR TO VERIFY JBOX TYPE TO ENSURE PROPERINSTALLATION AND BACKING FOR ITEM KEYNOTED
15 DOORBELL AND DOORBELL ON/OFF SWITCH(COMMUNICATION FEATURES ROOMS ONLY)SIGNAGE ASREQ'D.
16 PLACE TV OUTLETS AND CONNECTIONS ON WALL OUTSIDEAREA OF BRACKET AND CONCEALED FROM VIEW BY TV
17 DEDICATED CIRCUIT FOR WASHER/DRYER. DIRECT VENTTO EXTERIOR
FURNISHING SCHEDULE
GUESTROOM FURNISHINGS
GR-105 SOFA - SLEEP BETWEEN ARMS
GR-201 SCONCE - NIGHTSTAND
GR-203 PENDANT LIGHT - PRODUCTIVITY TABLE
GR-205 LAMP - FLOOR LAMP
GR-308 NIGHTSTAND - REGULAR
GR-312 TABLE - NESTING
GR-314 TABLE - PRODUCTIVITY TABLE (STUDIO)
GR-318 DRESSER - HIGHBOY
GR-321 CLOSET - KING STUDIO SUITE
GR-326 VANITY - STUDIO AND 1-BEDROOM SUITES
GR-400 STATIC DRAPARY PANELS
GR-403 ROLLER SHADE - GUESTROOMS (MANUAL,SHEER/BLACK-OUT, 8' W)
GR-412 VALENCE FOR 8' WINDOW
GR-503 ART- ENTRY
GR-504 ART- SLEEPING/LIVING
GR-506 MIRROR - GUESTROOM FULL LENGTH
GR-800 KITCHENETTE - 1-BEDROOM
GR-900 GUESTROOM REFRIGERATOR
GR-901 GUESTROOM DISHWASHER
GR-902 GUESTROOM COOKTOP - 2 BURNER
GR-904 GARBAGE DISPOSAL 1/3HP
GR-905 MICROWAVE- WITH RECIRCULATING HOOD
GR-906GR-911 TELEVISION & TELEVISION MOUNT
GR-907 CLOCK/RADIO
GR-908 TELEPHONE - GUESTROOM
GR-KS BED - KING (GR-301, 303, 600)
OWNER SPECIFIED - OWNER FURNISHED
OP-706 FIRE EXTINGUISHER CABINET
PLUMBING/MECHANICAL FIXTURES
PF-01 TOILET - GUESTROOM
PF-03 SHOWER BASE - 60" X 36" WITH LINEARDRAIN
PF-07 LAVATORY - UNDERMOUNT, 20" X 14"
PF-11 SHOWER HEAD - 2 IN 1
PF-13 SHOWER/TUB VALVE & CONTROL
PF-15 FAUCET - LAVATORY
PF-40 SINK - KITCHENETTE
PF-41 FAUCET - KITCHENETTE
TOILET ACCESSORIES
HD-01 DUAL TOILET PAPER HOLDER
HD-04 WALL-MOUNTED ROBE HOOK
HD-04.1 TOWEL BAR
HD-05.2 SLIDING SHOWER DOOR
HD-08 18" GRAB BAR
HD-16 BULK AMENITY DISPENSER ATSHOWERS/TUBS
HD-18 FOOT LEDGE FOR SHOWER
HD-18.1 SOAP SHELF
HD-21 BULK AMENITY DISPENSER AT LAVATORIES
0'1' 2'4'
SCALE: 1/2" = 1'-0"
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
Revision Schedule
Number Description Date
W/DW/DM
A
A
M TVTVSD
SD
SD
SD
TV
A-417B5
1
2
4
A-417B
6
7
8
9
D-G03
D-G03
D-G05
D-G01
D-G04
XE1/2
P1.2
P1.1
P1.1
XE1/2
P3.1
P3.1
12' - 8 1/4"5' - 11"6' - 6 1/2"12' - 3"2' - 1"2' - 0"3' - 2 1/2"
13' - 2 1/4"4' - 10 3/4"6' - 10"
GR-323
GR-314
GR-504
GR-908
GR-308
GR-907
GR-201
GR-KS
GR-317
GR-906GR-911
GR-308
GR-201
GR-103GR-103
GR-103GR-103
GR-108
GR-312
GR-316
GR-508
GR-326
GR-901
GR-903
GR-900
1' - 10 3/4"
GR-400GR-400
XE1/2
A-417B3
GR-506
GR-906GR-911
D-G02
CL-B8' - 0"
CL-B27' - 6"
CL-B8' - 0"
CL-B8' - 0"
CL-B27' - 6"
CL-A8' - 0"
GR-410GR-400 GR-400
EQEQ3' - 1"1' - 3" 1' - 3"2' - 2"5' - 10 1/4"1' - 4"1' - 0"EQ EQ6' - 0"EQ EQ
1' - 5"EQEQEQ EQ
1' - 0"1' - 0"
1
1
1
1
1
1
1
1' - 5"1
PLANELEV
DUPLEX OUTLET
QUADPLEX OUTLET
GFCI OUTLET
CAT6, RJ45 INTERNET OUTLET
TELEPHONE OUTLET
WALL MOUNTED WIRELESS THERMOSTAT
POWER OUTLET WITH USB PORTS
CATV OUTLET
ELECTRICAL SWITCH
FLOOR OUTLET
POWER AND SIGNAL LEGEND:
POWER SUPPLY
JUNCTION BOX
DOOR BELL HARDWIRED TO DOORBELL LIGHT - MOUNT @ 46" A.F.F TO CENTER OF BUTTON (FOR COMMUNICATIONS FEATURES ROOMS ONLY)
CEILING FIXTURE LEGEND:
6" RECESSED CAN DOWNLIGHT
DECORATIVE FLUSH MOUNT LIGHT
PENDENT TYPE SPRINKLERS
SMOKE DETECTOR
EXHAUST FAN / GRILLE
LINEAR SURFACE MOUNTED CONTINUOUS LED SYSTEM W/ FIXED MOUNTING CLIPS & FROSTED LENS / 3 WATTS PER FOOT, MLV/FWD
ELECTRICAL OUTLET HEIGHTS (U.N.O)
TYPICAL OUTLET - 15" A.F.F
TYPICAL ACCESSIBLE WALL OUTLET - 18" A.F.F
BATHROOM VANITY OUTLET - 42" A.F.F
TYP. KITCHEN OUTLET - 42" A.F.F
ADA KITCHEN OUTLET - 46" A.F.F
ADA BATHROOM VANITY OUTLET - 44" A.F.F
ELECTRICAL SWITCH HEIGHTS (U.N.O)
SWITCH - 44" A.F.F
THERMOSTAT REMOTE - 48" A.F.F MAX TO TOP OF SWITCH
SD
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216UNIT PLAN - KING1-BEDROOM
A-417
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
1/2" = 1'-0" Reference: 1 / A-102
1KING 1-BEDROOM UNIT CONSTRUCTION PLAN
Units x02
1/2" = 1'-0"2 KING 1-BEDROOM UNIT REFLECTED CEILING PLAN
Units x02 0'1' 2'4'
SCALE: 1/2" = 1'-0"
2
5
2
2
2
5
2
2
FURNISHING SCHEDULE
GUESTROOM FURNISHINGS
GR-103 CHAIR - KITCHEN STOOL
GR-108 SOFA - SECTIONAL SLEEPER
GR-201 SCONCE - NIGHTSTAND
GR-203 PENDANT LIGHT - PRODUCTIVITY TABLE
GR-204 CEILING LIGHT - 1-BEDROOM SUITE
GR-205 LAMP - FLOOR LAMP
GR-308 NIGHTSTAND - REGULAR
GR-312 TABLE - NESTING
GR-314 TABLE - PRODUCTIVITY TABLE (STUDIO)
GR-316 CONSOLE - LIVING ROOM (1-BEDROOM)
GR-317 DRESSER - BEDROOM (1-BEDROOM)
GR-323 CLOSET - KING 1-BEDROOM SUITE
GR-326 VANITY - STUDIO AND 1-BEDROOM SUITES
GR-400 STATIC DRAPARY PANELS
GR-403 ROLLER SHADE - GUESTROOMS (MANUAL,SHEER/BLACK-OUT, 8' W)
GR-410 VALENCE FOR 5' WINDOW
GR-413 VALENCE FOR 5' WINDOW - ONE DRAPERYPANEL
GR-504 ART- SLEEPING/LIVING
GR-505 WALL HOOK
FURNISHING SCHEDULE
GR-506 MIRROR - GUESTROOM FULL LENGTH
GR-508 MIRROR - GUESTROOM VANITY
GR-800 KITCHENETTE - 1-BEDROOM
GR-900 GUESTROOM REFRIGERATOR
GR-901 GUESTROOM DISHWASHER
GR-903 GUESTROOM COOKTOP - 4 BURNER
GR-904 GARBAGE DISPOSAL 1/3HP
GR-905 MICROWAVE- WITH RECIRCULATING HOOD
GR-906GR-911 TELEVISION & TELEVISION MOUNT
GR-907 CLOCK/RADIO
GR-908 TELEPHONE - GUESTROOM
GR-909/910 GUESTROOM STACKED WASHER/DRYER
GR-KS BED - KING (GR-301, 303, 600)
HILTON SPECIFIED - OWNER FURNISHED
OF-702A CHAIR - BALCONY CHAIR
OF-705 TABLE - 17" D OUTDOOR SIDE TABLE
OWNER SPECIFIED - OWNER FURNISHED
FURNISHING SCHEDULE
OP-706 FIRE EXTINGUISHER CABINET
PLUMBING/MECHANICAL FIXTURES
PF-01 TOILET - GUESTROOM
PF-03 SHOWER BASE - 60" X 36" WITH LINEARDRAIN
PF-07 LAVATORY - UNDERMOUNT, 20" X 14"
PF-11 SHOWER HEAD - 2 IN 1
PF-13 SHOWER/TUB VALVE & CONTROL
PF-15 FAUCET - LAVATORY
PF-40 SINK - KITCHENETTE
PF-41 FAUCET - KITCHENETTE
TOILET ACCESSORIES
HD-01 DUAL TOILET PAPER HOLDER
HD-04 WALL-MOUNTED ROBE HOOK
HD-04.1 TOWEL BAR
HD-05.2 SLIDING SHOWER DOOR
HD-08 18" GRAB BAR
HD-16 BULK AMENITY DISPENSER ATSHOWERS/TUBS
HD-18 FOOT LEDGE FOR SHOWER
HD-18.1 SOAP SHELF
HD-21 BULK AMENITY DISPENSER AT LAVATORIES
KEYNOTES - UNIT PLANS
1 ALIGN
2 GENERAL CONTRACTOR TO COORDINATE W/ FURNITUREFABRICATOR WHERE NECESSARY TO PROVIDE PROPERBLOCKING IN WALL FOR ITEM KEYNOTED
3 NO FINISHES UNDER THE SHOWER PAN / TUB
4 NO FINISHES UNDER MILLWORK CABINETRY
5 TV AND MOUNT NOT TO PROJECT MORE THAN 4" FROMWALL
6 MOTORIZED BLINDS. PROVIDE JUNCTION BOX BEHINDVALENCE FOR POWER CONNECTION AND PERMANENTLYINSTALLED SWITCH ON WALL TO CONTROL BLINDS.
7 SWITCH CONTROLLING UNDER CABINET LIGHTING ATKITCHEN TO BE GANGED WITH LIGHTING AT ENTRY
8 SWITCH CONTROLLING GARBAGE DISPOSAL-REFER TOHADG FOR ACCESSIBLE ROOM REQ'S.
9 DEDICATED CIRCUIT FOR GARBAGE DISPOSAL
10 MASTER SWITCH
11 DEDICATED CIRCUIT FOR INDUCTION COOKTOP
12 DEDICATED CIRCUIT FOR DISHWASHER
13 DEDICATED CIRCUIT FOR REFRIGERATOR
14 ELECTRIC VANITY MIRROR - HARDWIRE FIXTURE TO WALL-CONTRACTOR TO VERIFY JBOX TYPE TO ENSURE PROPERINSTALLATION AND BACKING FOR ITEM KEYNOTED
15 DOORBELL AND DOORBELL ON/OFF SWITCH(COMMUNICATION FEATURES ROOMS ONLY)SIGNAGE ASREQ'D.
16 PLACE TV OUTLETS AND CONNECTIONS ON WALL OUTSIDEAREA OF BRACKET AND CONCEALED FROM VIEW BY TV
17 DEDICATED CIRCUIT FOR WASHER/DRYER. DIRECT VENTTO EXTERIOR
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
Revision Schedule
Number Description Date
W/DTVTVTV
A-417B5
1
2
4
A-417B
6
7
8
9
A-417B3
CPT-02 CPT-01
RES-01
CT-01
CPT-10
7' - 0"11' - 0"FULL TILETILE
FULL
FULL TILE
FULL TILEEQEQFULL TILESF-01
SF-01 SF-01
WC-01
WC-01
WC-01
WC-01 WC-01WC-01
WC-01
WC-01
WC-01
WC-01
6
A-510
Sim
8
A-510
Sim
9
A-510
Sim
1
A-510
Sim
PLANELEV
DUPLEX OUTLET
QUADPLEX OUTLET
GFCI OUTLET
CAT6, RJ45 INTERNET OUTLET
TELEPHONE OUTLET
WALL MOUNTED WIRELESS THERMOSTAT
POWER OUTLET WITH USB PORTS
CATV OUTLET
ELECTRICAL SWITCH
FLOOR OUTLET
POWER AND SIGNAL LEGEND:
POWER SUPPLY
JUNCTION BOX
DOOR BELL HARDWIRED TO DOORBELL LIGHT - MOUNT @ 46" A.F.F TO CENTER OF BUTTON (FOR COMMUNICATIONS FEATURES ROOMS ONLY)
CEILING FIXTURE LEGEND:
6" RECESSED CAN DOWNLIGHT
DECORATIVE FLUSH MOUNT LIGHT
PENDENT TYPE SPRINKLERS
SMOKE DETECTOR
EXHAUST FAN / GRILLE
LINEAR SURFACE MOUNTED CONTINUOUS LED SYSTEM W/ FIXED MOUNTING CLIPS & FROSTED LENS / 3 WATTS PER FOOT, MLV/FWD
ELECTRICAL OUTLET HEIGHTS (U.N.O)
TYPICAL OUTLET - 15" A.F.F
TYPICAL ACCESSIBLE WALL OUTLET - 18" A.F.F
BATHROOM VANITY OUTLET - 42" A.F.F
TYP. KITCHEN OUTLET - 42" A.F.F
ADA KITCHEN OUTLET - 46" A.F.F
ADA BATHROOM VANITY OUTLET - 44" A.F.F
ELECTRICAL SWITCH HEIGHTS (U.N.O)
SWITCH - 44" A.F.F
THERMOSTAT REMOTE - 48" A.F.F MAX TO TOP OF SWITCH
SD
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216UNIT PLAN - KING1-BEDROOM - ELEC,DATA & FLOOR FINISHPLAN
A-417A
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
1/2" = 1'-0"1KING 1-BEDROOM UNIT ELECTRICAL & DATA PLAN
Units x02
1/2" = 1'-0"2KING 1-BEDROOM UNIT FLOOR & WALL FINISH PLAN
Units x02
3
1512
8
9
11
7
10
16
17
13
16
FURNISHING SCHEDULE
GUESTROOM FURNISHINGS
GR-103 CHAIR - KITCHEN STOOL
GR-108 SOFA - SECTIONAL SLEEPER
GR-201 SCONCE - NIGHTSTAND
GR-205 LAMP - FLOOR LAMP
GR-308 NIGHTSTAND - REGULAR
GR-312 TABLE - NESTING
GR-314 TABLE - PRODUCTIVITY TABLE (STUDIO)
GR-316 CONSOLE - LIVING ROOM (1-BEDROOM)
GR-317 DRESSER - BEDROOM (1-BEDROOM)
GR-323 CLOSET - KING 1-BEDROOM SUITE
GR-326 VANITY - STUDIO AND 1-BEDROOM SUITES
GR-400 STATIC DRAPARY PANELS
GR-504 ART- SLEEPING/LIVING
GR-506 MIRROR - GUESTROOM FULL LENGTH
GR-508 MIRROR - GUESTROOM VANITY
GR-800 KITCHENETTE - 1-BEDROOM
GR-900 GUESTROOM REFRIGERATOR
GR-901 GUESTROOM DISHWASHER
GR-903 GUESTROOM COOKTOP - 4 BURNER
GR-904 GARBAGE DISPOSAL 1/3HP
FURNISHING SCHEDULE
GR-906GR-911 TELEVISION & TELEVISION MOUNT
GR-907 CLOCK/RADIO
GR-908 TELEPHONE - GUESTROOM
GR-909/910 GUESTROOM STACKED WASHER/DRYER
GR-KS BED - KING (GR-301, 303, 600)
OWNER SPECIFIED - OWNER FURNISHED
OP-706 FIRE EXTINGUISHER CABINET
PLUMBING/MECHANICAL FIXTURES
PF-01 TOILET - GUESTROOM
PF-03 SHOWER BASE - 60" X 36" WITH LINEARDRAIN
PF-07 LAVATORY - UNDERMOUNT, 20" X 14"
PF-11 SHOWER HEAD - 2 IN 1
PF-13 SHOWER/TUB VALVE & CONTROL
PF-15 FAUCET - LAVATORY
PF-40 SINK - KITCHENETTE
PF-41 FAUCET - KITCHENETTE
FURNISHING SCHEDULE
TOILET ACCESSORIES
HD-01 DUAL TOILET PAPER HOLDER
HD-04.1 TOWEL BAR
HD-05.2 SLIDING SHOWER DOOR
HD-08 18" GRAB BAR
HD-16 BULK AMENITY DISPENSER ATSHOWERS/TUBS
HD-18 FOOT LEDGE FOR SHOWER
HD-18.1 SOAP SHELF
HD-21 BULK AMENITY DISPENSER AT LAVATORIES
KEYNOTES - UNIT PLANS
1 ALIGN
2 GENERAL CONTRACTOR TO COORDINATE W/ FURNITUREFABRICATOR WHERE NECESSARY TO PROVIDE PROPERBLOCKING IN WALL FOR ITEM KEYNOTED
3 NO FINISHES UNDER THE SHOWER PAN / TUB
4 NO FINISHES UNDER MILLWORK CABINETRY
5 TV AND MOUNT NOT TO PROJECT MORE THAN 4" FROMWALL
6 MOTORIZED BLINDS. PROVIDE JUNCTION BOX BEHINDVALENCE FOR POWER CONNECTION AND PERMANENTLYINSTALLED SWITCH ON WALL TO CONTROL BLINDS.
7 SWITCH CONTROLLING UNDER CABINET LIGHTING ATKITCHEN TO BE GANGED WITH LIGHTING AT ENTRY
8 SWITCH CONTROLLING GARBAGE DISPOSAL-REFER TOHADG FOR ACCESSIBLE ROOM REQ'S.
9 DEDICATED CIRCUIT FOR GARBAGE DISPOSAL
10 MASTER SWITCH
11 DEDICATED CIRCUIT FOR INDUCTION COOKTOP
12 DEDICATED CIRCUIT FOR DISHWASHER
13 DEDICATED CIRCUIT FOR REFRIGERATOR
14 ELECTRIC VANITY MIRROR - HARDWIRE FIXTURE TO WALL-CONTRACTOR TO VERIFY JBOX TYPE TO ENSURE PROPERINSTALLATION AND BACKING FOR ITEM KEYNOTED
15 DOORBELL AND DOORBELL ON/OFF SWITCH(COMMUNICATION FEATURES ROOMS ONLY)SIGNAGE ASREQ'D.
16 PLACE TV OUTLETS AND CONNECTIONS ON WALL OUTSIDEAREA OF BRACKET AND CONCEALED FROM VIEW BY TV
17 DEDICATED CIRCUIT FOR WASHER/DRYER. DIRECT VENTTO EXTERIOR
0'1' 2'4'
SCALE: 1/2" = 1'-0"
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
Revision Schedule
Number Description Date
TV
WD-01
WD-01
PC-04
WC-01
RB-01PT-03PT-03
W-K
D-G04
GR-403GR-413
D-G05
WC-01
RB-01
WC-01
RB-01
PT-11PL-01
D-G01
PT-03PL-02
WC-01
2' - 1 1/2"
RB-01
WD-01
WD-01
5' - 0"0' - 8"
GR-505
3' - 4 1/2"5' - 1"0' - 9"
D-G03D-G02
PT-03PL-02 4' - 2"4' - 1 1/4"
SF-01
W-H
RB-01
WD-01
SF-01
WD-01
WD-01
GR-413
GR-403
SF-01
RB-01
16
A-510
Sim
GR-410GR-403
GR-400
4' - 2"6' - 0"
WC-01
RB-01
GR-906GR-911
GR-317
4' - 2 3/4"5' - 0"WC-01
D-G05
PT-03
PT-03
RB-01
GR-504
WC-01
RB-10GR-KS
GR-505
5' - 0"RB-01
PT-11 PL-01
WC-01
D-G01
PLAN ELEV
DUPLEX OUTLET
QUADPLEX OUTLET
GFCI OUTLET
CAT6, RJ45 INTERNET OUTLET
TELEPHONE OUTLET
WALL MOUNTED WIRELESS THERMOSTAT
POWER OUTLET WITH USB PORTS
CATV OUTLET
ELECTRICAL SWITCH
FLOOR OUTLET
POWER AND SIGNAL LEGEND:
POWER SUPPLY
JUNCTION BOX
DOOR BELL HARDWIRED TO DOORBELL LIGHT - MOUNT @ 46" A.F.F TO CENTER OF BUTTON (FOR COMMUNICATIONS FEATURES ROOMS ONLY)
CEILING FIXTURE LEGEND:
6" RECESSED CAN DOWNLIGHT
DECORATIVE FLUSH MOUNT LIGHT
PENDENT TYPE SPRINKLERS
SMOKE DETECTOR
EXHAUST FAN / GRILLE
LINEAR SURFACE MOUNTED CONTINUOUS LED SYSTEM W/ FIXED MOUNTING CLIPS & FROSTED LENS / 3 WATTS PER FOOT, MLV/FWD
ELECTRICAL OUTLET HEIGHTS (U.N.O)
TYPICAL OUTLET - 15" A.F.F
TYPICAL ACCESSIBLE WALL OUTLET - 18" A.F.F
BATHROOM VANITY OUTLET - 42" A.F.F
TYP. KITCHEN OUTLET - 42" A.F.F
ADA KITCHEN OUTLET - 46" A.F.F
ADA BATHROOM VANITY OUTLET - 44" A.F.F
ELECTRICAL SWITCH HEIGHTS (U.N.O)
SWITCH - 44" A.F.F
THERMOSTAT REMOTE - 48" A.F.F MAX TO TOP OF SWITCH
SD
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216UNIT INT. ELEVATIONS -KING 1-BEDROOM
A-417B
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
FFL
FFL
1/2" = 1'-0" Reference: 1 / A-417
1KING 1-BEDROOM ELEVATION A
Units x02
1/2" = 1'-0" Reference: 1 / A-417
2KING 1-BEDROOM ELEVATION B
Units x02
1/2" = 1'-0" Reference: 1 / A-417
4KING 1-BEDROOM ELEVATION C
Units x02
1/2" = 1'-0" Reference: 1 / A-417
5KING 1-BEDROOM ELEVATION D
Units x02
FFL
1/2" = 1'-0" Reference: 1 / A-417
6KING 1-BEDROOM ELEVATION E
Units x02
1/2" = 1'-0" Reference: 1 / A-417
7KING 1-BEDROOM ELEVATION F
Units x02
1/2" = 1'-0" Reference: 1 / A-417
8KING 1-BEDROOM ELEVATION G
Units x02
1/2" = 1'-0" Reference: 1 / A-417
9 KING 1-BEDROOM ELEVATION H
Units x02
FFL
1/2" = 1'-0" Reference: 1 / A-417
3KING 1-BEDROOM ELEVATION B1
Units x02
0'1' 2'4'
SCALE: 1/2" = 1'-0"
FURNISHING SCHEDULE
GUESTROOM FURNISHINGS
GR-103 CHAIR - KITCHEN STOOL
GR-105 SOFA - SLEEP BETWEEN ARMS
GR-108 SOFA - SECTIONAL SLEEPER
GR-201 SCONCE - NIGHTSTAND
GR-203 PENDANT LIGHT - PRODUCTIVITY TABLE
GR-204 CEILING LIGHT - 1-BEDROOM SUITE
GR-205 LAMP - FLOOR LAMP
GR-308 NIGHTSTAND - REGULAR
GR-312 TABLE - NESTING
GR-314 TABLE - PRODUCTIVITY TABLE (STUDIO)
GR-316 CONSOLE - LIVING ROOM (1-BEDROOM)
GR-317 DRESSER - BEDROOM (1-BEDROOM)
GR-318 DRESSER - HIGHBOY
GR-321 CLOSET - KING STUDIO SUITE
GR-323 CLOSET - KING 1-BEDROOM SUITE
GR-326 VANITY - STUDIO AND 1-BEDROOM SUITES
GR-400 STATIC DRAPARY PANELS
GR-403 ROLLER SHADE - GUESTROOMS (MANUAL,SHEER/BLACK-OUT, 8' W)
GR-410 VALENCE FOR 5' WINDOW
GR-412 VALENCE FOR 8' WINDOW
GR-413 VALENCE FOR 5' WINDOW - ONE DRAPERYPANEL
GR-504 ART- SLEEPING/LIVING
GR-505 WALL HOOK
GR-506 MIRROR - GUESTROOM FULL LENGTH
GR-508 MIRROR - GUESTROOM VANITY
GR-800 KITCHENETTE - 1-BEDROOM
GR-900 GUESTROOM REFRIGERATOR
GR-901 GUESTROOM DISHWASHER
GR-902 GUESTROOM COOKTOP - 2 BURNER
GR-903 GUESTROOM COOKTOP - 4 BURNER
GR-904 GARBAGE DISPOSAL 1/3HP
GR-905 MICROWAVE- WITH RECIRCULATING HOOD
GR-906GR-911 TELEVISION & TELEVISION MOUNT
FURNISHING SCHEDULE
GR-907 CLOCK/RADIO
GR-908 TELEPHONE - GUESTROOM
GR-909/910 GUESTROOM STACKED WASHER/DRYER
GR-KS BED - KING (GR-301, 303, 600)
HILTON SPECIFIED - OWNER FURNISHED
OF-702A CHAIR - BALCONY CHAIR
OF-705 TABLE - 17" D OUTDOOR SIDE TABLE
OWNER SPECIFIED - OWNER FURNISHED
OP-706 FIRE EXTINGUISHER CABINET
PLUMBING/MECHANICAL FIXTURES
PF-01 TOILET - GUESTROOM
PF-03 SHOWER BASE - 60" X 36" WITH LINEARDRAIN
PF-07 LAVATORY - UNDERMOUNT, 20" X 14"
PF-11 SHOWER HEAD - 2 IN 1
PF-13 SHOWER/TUB VALVE & CONTROL
PF-15 FAUCET - LAVATORY
PF-40 SINK - KITCHENETTE
PF-41 FAUCET - KITCHENETTE
TOILET ACCESSORIES
HD-01 DUAL TOILET PAPER HOLDER
HD-04 WALL-MOUNTED ROBE HOOK
HD-04.1 TOWEL BAR
HD-05.2 SLIDING SHOWER DOOR
HD-08 18" GRAB BAR
HD-16 BULK AMENITY DISPENSER ATSHOWERS/TUBS
HD-18 FOOT LEDGE FOR SHOWER
HD-18.1 SOAP SHELF
HD-21 BULK AMENITY DISPENSER AT LAVATORIES
KEYNOTES - UNIT PLANS
1 ALIGN
2 GENERAL CONTRACTOR TO COORDINATE W/ FURNITUREFABRICATOR WHERE NECESSARY TO PROVIDE PROPERBLOCKING IN WALL FOR ITEM KEYNOTED
3 NO FINISHES UNDER THE SHOWER PAN / TUB
4 NO FINISHES UNDER MILLWORK CABINETRY
5 TV AND MOUNT NOT TO PROJECT MORE THAN 4" FROMWALL
6 MOTORIZED BLINDS. PROVIDE JUNCTION BOX BEHINDVALENCE FOR POWER CONNECTION AND PERMANENTLYINSTALLED SWITCH ON WALL TO CONTROL BLINDS.
7 SWITCH CONTROLLING UNDER CABINET LIGHTING ATKITCHEN TO BE GANGED WITH LIGHTING AT ENTRY
8 SWITCH CONTROLLING GARBAGE DISPOSAL-REFER TOHADG FOR ACCESSIBLE ROOM REQ'S.
9 DEDICATED CIRCUIT FOR GARBAGE DISPOSAL
10 MASTER SWITCH
11 DEDICATED CIRCUIT FOR INDUCTION COOKTOP
12 DEDICATED CIRCUIT FOR DISHWASHER
13 DEDICATED CIRCUIT FOR REFRIGERATOR
14 ELECTRIC VANITY MIRROR - HARDWIRE FIXTURE TO WALL-CONTRACTOR TO VERIFY JBOX TYPE TO ENSURE PROPERINSTALLATION AND BACKING FOR ITEM KEYNOTED
15 DOORBELL AND DOORBELL ON/OFF SWITCH(COMMUNICATION FEATURES ROOMS ONLY)SIGNAGE ASREQ'D.
16 PLACE TV OUTLETS AND CONNECTIONS ON WALL OUTSIDEAREA OF BRACKET AND CONCEALED FROM VIEW BY TV
17 DEDICATED CIRCUIT FOR WASHER/DRYER. DIRECT VENTTO EXTERIOR
1/2" = 1'-0"
POWER AND SIGNAL LEGEND Copy 1 Copy 1
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
Revision Schedule
Number Description Date
WDM
A
A
M WDTVTVSD
SD
SD
SD
TV
12' - 9"A-418B
3
1
42
A-418B9
6
7
8
D-G05A
P2.1
P1.2
P1.1
P3.1
D-G01A
D-G04A
GR-316GR-906GR-911
GR-312
GR-101
GR-105
GR-205
3' - 0 1/4"
GR-324
GR-308
GR-201
GR-201
GR-308
W-K
13' - 3"
4' - 9"2' - 1 1/2"GR-314
GR-103GR-103
GR-103GR-103
GR-KM
GR-504
GR-317
GR-906GR-911
GR-900
GR-901
GR-903
GR-907
GR-908
GR-400
GR-400
A-418B5
D-G02A
A-4242
OF-702A
OF-705
OF-702A
GR-910
GR-909
GR-913
PF-40
PF-41
GR-803
GR-400
14' - 3"
GR-410GR-400 GR-400
CL-B8' - 0"
CL-B8' - 0"
1
1
1
1 1
1
1
1' - 5"
EQ EQ
EQ EQ
2' - 11"EQ1' - 3"1' - 3"
EQ
4' - 0"4' - 0"6' - 5 1/4"3' - 3 1/2"3' - 1"1' - 0"1' - 4"1' - 0"1' - 0"A-4243 Sim
GR-203
GR-203
GR-204
GR-413
GR-405
GR-405
GR-410
GR-400
GR-400
GR-913
PLANELEV
DUPLEX OUTLET
QUADPLEX OUTLET
GFCI OUTLET
CAT6, RJ45 INTERNET OUTLET
TELEPHONE OUTLET
WALL MOUNTED WIRELESS THERMOSTAT
POWER OUTLET WITH USB PORTS
CATV OUTLET
ELECTRICAL SWITCH
FLOOR OUTLET
POWER AND SIGNAL LEGEND:
POWER SUPPLY
JUNCTION BOX
DOOR BELL HARDWIRED TO DOORBELL LIGHT - MOUNT @ 46" A.F.F TO CENTER OF BUTTON (FOR COMMUNICATIONS FEATURES ROOMS ONLY)
CEILING FIXTURE LEGEND:
6" RECESSED CAN DOWNLIGHT
DECORATIVE FLUSH MOUNT LIGHT
PENDENT TYPE SPRINKLERS
SMOKE DETECTOR
EXHAUST FAN / GRILLE
LINEAR SURFACE MOUNTED CONTINUOUS LED SYSTEM W/ FIXED MOUNTING CLIPS & FROSTED LENS / 3 WATTS PER FOOT, MLV/FWD
ELECTRICAL OUTLET HEIGHTS (U.N.O)
TYPICAL OUTLET - 15" A.F.F
TYPICAL ACCESSIBLE WALL OUTLET - 18" A.F.F
BATHROOM VANITY OUTLET - 42" A.F.F
TYP. KITCHEN OUTLET - 42" A.F.F
ADA KITCHEN OUTLET - 46" A.F.F
ADA BATHROOM VANITY OUTLET - 44" A.F.F
ELECTRICAL SWITCH HEIGHTS (U.N.O)
SWITCH - 44" A.F.F
THERMOSTAT REMOTE - 48" A.F.F MAX TO TOP OF SWITCH
SD
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216UNIT PLAN - KING1-BEDROOM ADAMOBILITY
A-418
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
1/2" = 1'-0" Reference: 1 / A-103
1KING 1-BEDROOM ADA MOBILITY CONSTRUCTION PLAN
Unit 301
1/2" = 1'-0"2 KING 1-BEDROOM ADA MOBILITY REFLECTED CEILING PLAN
Unit 301 0'1' 2'4'
SCALE: 1/2" = 1'-0"
25
2
2
2
2
2
5
FURNISHING SCHEDULE
GUESTROOM FURNISHINGS
GR-101 CHAIR - LOUNGE CHAIR IN STUIDOS
GR-103 CHAIR - KITCHEN STOOL
GR-105 SOFA - SLEEP BETWEEN ARMS
GR-200 SCONCE - PIN-UP
GR-201 SCONCE - NIGHTSTAND
GR-203 PENDANT LIGHT - PRODUCTIVITY TABLE
GR-204 CEILING LIGHT - 1-BEDROOM SUITE
GR-205 LAMP - FLOOR LAMP
GR-308 NIGHTSTAND - REGULAR
GR-312 TABLE - NESTING
GR-314 TABLE - PRODUCTIVITY TABLE (STUDIO)
GR-316 CONSOLE - LIVING ROOM (1-BEDROOM)
GR-317 DRESSER - BEDROOM (1-BEDROOM)
GR-324 CLOSET - ACCESSIBLE KING 1-BEDROOMSUITE
GR-327 VANITY - ACCESSIBLE SUITES
GR-328 BATH CADDY - ACCESSIBLE SUITES
GR-400 STATIC DRAPARY PANELS
GR-405 ROLLER SHADE - GUESTROOMS (MANUAL,SHEER/BLACK-OUT, 8' W)
FURNISHING SCHEDULE
GR-410 VALENCE FOR 5' WINDOW
GR-413 VALENCE FOR 5' WINDOW - ONE DRAPERYPANEL
GR-503 ART- ENTRY
GR-504 ART- SLEEPING/LIVING
GR-505 WALL HOOK
GR-507 MIRROR - ADA VANITY
GR-800 KITCHENETTE - 1-BEDROOM
GR-802 KITCHENETTE - EFFICIENCY SUITE
GR-803 KITCHENETTE - ONE BEDROOM SUITE
GR-900 GUESTROOM REFRIGERATOR
GR-901 GUESTROOM DISHWASHER
GR-903 GUESTROOM COOKTOP - 4 BURNER
GR-904 GARBAGE DISPOSAL 1/3HP
GR-906GR-911 TELEVISION & TELEVISION MOUNT
GR-907 CLOCK/RADIO
GR-908 TELEPHONE - GUESTROOM
GR-909 GUESTROOM WASHING MACHINE
GR-910 GUESTROOM DRYER
GR-913 COUNTERTOP MICROWAVE
FURNISHING SCHEDULE
GR-KM BED - KING MOBILITY (GR-301, 304, 600, 602)
HILTON SPECIFIED - OWNER FURNISHED
OF-702A CHAIR - BALCONY CHAIR
OF-705 TABLE - 17" D OUTDOOR SIDE TABLE
PLUMBING/MECHANICAL FIXTURES
PF-01 TOILET - GUESTROOM
PF-03 SHOWER BASE - 60" X 36" WITH LINEARDRAIN
PF-06 BATHTUB - 5' X 32" WITH SIDE LEDGE
PF-07 LAVATORY - UNDERMOUNT, 20" X 14"
PF-10 SHOWER HEAD - HIGH
PF-12 SHOWER HEAD - HAND HELD ON SLIDE BAR
PF-13 SHOWER/TUB VALVE & CONTROL
PF-14 BATHTUB FILL FAUCET
PF-15 FAUCET - LAVATORY
PF-40 SINK - KITCHENETTE
PF-41 FAUCET - KITCHENETTE
KEYNOTES - UNIT PLANS
1 ALIGN
2 GENERAL CONTRACTOR TO COORDINATE W/ FURNITUREFABRICATOR WHERE NECESSARY TO PROVIDE PROPERBLOCKING IN WALL FOR ITEM KEYNOTED
3 NO FINISHES UNDER THE SHOWER PAN / TUB
4 NO FINISHES UNDER MILLWORK CABINETRY
5 TV AND MOUNT NOT TO PROJECT MORE THAN 4" FROMWALL
6 MOTORIZED BLINDS. PROVIDE JUNCTION BOX BEHINDVALENCE FOR POWER CONNECTION AND PERMANENTLYINSTALLED SWITCH ON WALL TO CONTROL BLINDS.
7 SWITCH CONTROLLING UNDER CABINET LIGHTING ATKITCHEN TO BE GANGED WITH LIGHTING AT ENTRY
8 SWITCH CONTROLLING GARBAGE DISPOSAL-REFER TOHADG FOR ACCESSIBLE ROOM REQ'S.
9 DEDICATED CIRCUIT FOR GARBAGE DISPOSAL
10 MASTER SWITCH
11 DEDICATED CIRCUIT FOR INDUCTION COOKTOP
12 DEDICATED CIRCUIT FOR DISHWASHER
13 DEDICATED CIRCUIT FOR REFRIGERATOR
14 ELECTRIC VANITY MIRROR - HARDWIRE FIXTURE TO WALL-CONTRACTOR TO VERIFY JBOX TYPE TO ENSURE PROPERINSTALLATION AND BACKING FOR ITEM KEYNOTED
15 DOORBELL AND DOORBELL ON/OFF SWITCH(COMMUNICATION FEATURES ROOMS ONLY)SIGNAGE ASREQ'D.
16 PLACE TV OUTLETS AND CONNECTIONS ON WALL OUTSIDEAREA OF BRACKET AND CONCEALED FROM VIEW BY TV
17 DEDICATED CIRCUIT FOR WASHER/DRYER. DIRECT VENTTO EXTERIOR
FURNISHING SCHEDULE
TOILET ACCESSORIES
HD-02 DUAL TOILET PAPER HOLDER- ADA
HD-04 WALL-MOUNTED ROBE HOOK
HD-04.1 TOWEL BAR
HD-05 CURVED CURTAIN ROD AND SHOWERCURTAIN
HD-08 18" GRAB BAR
HD-09 24" GRAB BAR
HD-10 42" GRAB BAR AT ADA BATHTUB
HD-11 36" GRAB BAR
HD-11.1 42" GRAB BAR
HD-14.1 ROLL-IN SHOWER SEAT
HD-16 BULK AMENITY DISPENSER ATSHOWERS/TUBS
HD-18.1 SOAP SHELF
HD-20 12" GRAB BAR
HD-21 BULK AMENITY DISPENSER AT LAVATORIES
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
Revision Schedule
Number Description Date
WDTVTVTV
A-418B
3
1
42
A-418B9
6
7
8
GFCI
A-418B5FULL TILEFULL TILE
EQFULL TILE
SF-01
SF-01SF-01
WC-01
WC-01
WC-01
WC-01
WC-01
WC-01
WC-01
WC-01
RES-01
CPT-01
RES-01
8
A-510
Sim
9
A-510
Sim
7
A-510
Sim
7
A-510
Sim
PLANELEV
DUPLEX OUTLET
QUADPLEX OUTLET
GFCI OUTLET
CAT6, RJ45 INTERNET OUTLET
TELEPHONE OUTLET
WALL MOUNTED WIRELESS THERMOSTAT
POWER OUTLET WITH USB PORTS
CATV OUTLET
ELECTRICAL SWITCH
FLOOR OUTLET
POWER AND SIGNAL LEGEND:
POWER SUPPLY
JUNCTION BOX
DOOR BELL HARDWIRED TO DOORBELL LIGHT - MOUNT @ 46" A.F.F TO CENTER OF BUTTON (FOR COMMUNICATIONS FEATURES ROOMS ONLY)
CEILING FIXTURE LEGEND:
6" RECESSED CAN DOWNLIGHT
DECORATIVE FLUSH MOUNT LIGHT
PENDENT TYPE SPRINKLERS
SMOKE DETECTOR
EXHAUST FAN / GRILLE
LINEAR SURFACE MOUNTED CONTINUOUS LED SYSTEM W/ FIXED MOUNTING CLIPS & FROSTED LENS / 3 WATTS PER FOOT, MLV/FWD
ELECTRICAL OUTLET HEIGHTS (U.N.O)
TYPICAL OUTLET - 15" A.F.F
TYPICAL ACCESSIBLE WALL OUTLET - 18" A.F.F
BATHROOM VANITY OUTLET - 42" A.F.F
TYP. KITCHEN OUTLET - 42" A.F.F
ADA KITCHEN OUTLET - 46" A.F.F
ADA BATHROOM VANITY OUTLET - 44" A.F.F
ELECTRICAL SWITCH HEIGHTS (U.N.O)
SWITCH - 44" A.F.F
THERMOSTAT REMOTE - 48" A.F.F MAX TO TOP OF SWITCH
SD
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216UNIT PLAN - KING1-BEDROOM ADA -ELEC, DATA & FLOORFINISH PLAN
A-418A
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
0'1' 2'4'
SCALE: 1/2" = 1'-0"
1/2" = 1'-0"1KING 1-BEDROOM ADA MOBILITY ELECTRICAL & DATA PLAN
Unit 301
1/2" = 1'-0"2 KING 1-BEDROOM ADA MOBILITY FLOOR & WALL FINISH PLAN
Unit 301
16
16
15
710
12
8
9
11
13
17
3
14
FURNISHING SCHEDULE
GUESTROOM FURNISHINGS
GR-101 CHAIR - LOUNGE CHAIR IN STUIDOS
GR-103 CHAIR - KITCHEN STOOL
GR-105 SOFA - SLEEP BETWEEN ARMS
GR-201 SCONCE - NIGHTSTAND
GR-205 LAMP - FLOOR LAMP
GR-308 NIGHTSTAND - REGULAR
GR-312 TABLE - NESTING
GR-314 TABLE - PRODUCTIVITY TABLE (STUDIO)
GR-316 CONSOLE - LIVING ROOM (1-BEDROOM)
GR-317 DRESSER - BEDROOM (1-BEDROOM)
GR-324 CLOSET - ACCESSIBLE KING 1-BEDROOMSUITE
GR-327 VANITY - ACCESSIBLE SUITES
GR-328 BATH CADDY - ACCESSIBLE SUITES
GR-400 STATIC DRAPARY PANELS
GR-504 ART- SLEEPING/LIVING
GR-507 MIRROR - ADA VANITY
GR-800 KITCHENETTE - 1-BEDROOM
GR-803 KITCHENETTE - ONE BEDROOM SUITE
GR-900 GUESTROOM REFRIGERATOR
FURNISHING SCHEDULE
GR-901 GUESTROOM DISHWASHER
GR-903 GUESTROOM COOKTOP - 4 BURNER
GR-904 GARBAGE DISPOSAL 1/3HP
GR-906GR-911 TELEVISION & TELEVISION MOUNT
GR-907 CLOCK/RADIO
GR-908 TELEPHONE - GUESTROOM
GR-909 GUESTROOM WASHING MACHINE
GR-910 GUESTROOM DRYER
GR-913 COUNTERTOP MICROWAVE
GR-KM BED - KING MOBILITY (GR-301, 304, 600, 602)
PLUMBING/MECHANICAL FIXTURES
PF-01 TOILET - GUESTROOM
PF-06 BATHTUB - 5' X 32" WITH SIDE LEDGE
PF-07 LAVATORY - UNDERMOUNT, 20" X 14"
PF-12 SHOWER HEAD - HAND HELD ON SLIDE BAR
PF-13 SHOWER/TUB VALVE & CONTROL
PF-14 BATHTUB FILL FAUCET
PF-15 FAUCET - LAVATORY
PF-40 SINK - KITCHENETTE
FURNISHING SCHEDULE
PF-41 FAUCET - KITCHENETTE
TOILET ACCESSORIES
HD-02 DUAL TOILET PAPER HOLDER- ADA
HD-04 WALL-MOUNTED ROBE HOOK
HD-04.1 TOWEL BAR
HD-08 18" GRAB BAR
HD-09 24" GRAB BAR
HD-10 42" GRAB BAR AT ADA BATHTUB
HD-11 36" GRAB BAR
HD-11.1 42" GRAB BAR
HD-14.1 ROLL-IN SHOWER SEAT
HD-16 BULK AMENITY DISPENSER ATSHOWERS/TUBS
HD-18.1 SOAP SHELF
HD-20 12" GRAB BAR
HD-21 BULK AMENITY DISPENSER AT LAVATORIES
KEYNOTES - UNIT PLANS
1 ALIGN
2 GENERAL CONTRACTOR TO COORDINATE W/ FURNITUREFABRICATOR WHERE NECESSARY TO PROVIDE PROPERBLOCKING IN WALL FOR ITEM KEYNOTED
3 NO FINISHES UNDER THE SHOWER PAN / TUB
4 NO FINISHES UNDER MILLWORK CABINETRY
5 TV AND MOUNT NOT TO PROJECT MORE THAN 4" FROMWALL
6 MOTORIZED BLINDS. PROVIDE JUNCTION BOX BEHINDVALENCE FOR POWER CONNECTION AND PERMANENTLYINSTALLED SWITCH ON WALL TO CONTROL BLINDS.
7 SWITCH CONTROLLING UNDER CABINET LIGHTING ATKITCHEN TO BE GANGED WITH LIGHTING AT ENTRY
8 SWITCH CONTROLLING GARBAGE DISPOSAL-REFER TOHADG FOR ACCESSIBLE ROOM REQ'S.
9 DEDICATED CIRCUIT FOR GARBAGE DISPOSAL
10 MASTER SWITCH
11 DEDICATED CIRCUIT FOR INDUCTION COOKTOP
12 DEDICATED CIRCUIT FOR DISHWASHER
13 DEDICATED CIRCUIT FOR REFRIGERATOR
14 ELECTRIC VANITY MIRROR - HARDWIRE FIXTURE TO WALL-CONTRACTOR TO VERIFY JBOX TYPE TO ENSURE PROPERINSTALLATION AND BACKING FOR ITEM KEYNOTED
15 DOORBELL AND DOORBELL ON/OFF SWITCH(COMMUNICATION FEATURES ROOMS ONLY)SIGNAGE ASREQ'D.
16 PLACE TV OUTLETS AND CONNECTIONS ON WALL OUTSIDEAREA OF BRACKET AND CONCEALED FROM VIEW BY TV
17 DEDICATED CIRCUIT FOR WASHER/DRYER. DIRECT VENTTO EXTERIOR
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
Revision Schedule
Number Description Date
TV
WC-01SF-01
RB-01
D-G04A
W-K
D-G05A
PT-03
GR-405
PL-02
GR-324
GR-103
GR-413GR-405
GR-203GR-203
SF-01
RB-01
W-H
WD-01
WD-01 GR-410
GR-405
GR-400 GR-400
GR-316
PT-03PL-02
0' - 9"
WC-01
GR-505
D-G03AD-G02A
PT-03PL-02
WC-01
RB-01
PT-11 PL-01
WC-01
RB-01
D-G01A
6
SF-01W-K
RB-01
GR-410
16
A-510
Sim
GR-405
GR-400
WC-01
RB-01
GR-405
4' - 5 1/2"5' - 0"PT-03 PL-02RB-01
WC-01
D-G05A
RB-01
WC-01
6' - 2 1/2"
GR-405
WC-01
RB-10
PL-01PT-11
D-G01A
PLANELEV
DUPLEX OUTLET
QUADPLEX OUTLET
GFCI OUTLET
CAT6, RJ45 INTERNET OUTLET
TELEPHONE OUTLET
WALL MOUNTED WIRELESS THERMOSTAT
POWER OUTLET WITH USB PORTS
CATV OUTLET
ELECTRICAL SWITCH
FLOOR OUTLET
POWER AND SIGNAL LEGEND:
POWER SUPPLY
JUNCTION BOX
DOOR BELL HARDWIRED TO DOORBELL LIGHT - MOUNT @ 46" A.F.F TO CENTER OF BUTTON (FOR COMMUNICATIONS FEATURES ROOMS ONLY)
CEILING FIXTURE LEGEND:
6" RECESSED CAN DOWNLIGHT
DECORATIVE FLUSH MOUNT LIGHT
PENDENT TYPE SPRINKLERS
SMOKE DETECTOR
EXHAUST FAN / GRILLE
LINEAR SURFACE MOUNTED CONTINUOUS LED SYSTEM W/ FIXED MOUNTING CLIPS & FROSTED LENS / 3 WATTS PER FOOT, MLV/FWD
ELECTRICAL OUTLET HEIGHTS (U.N.O)
TYPICAL OUTLET - 15" A.F.F
TYPICAL ACCESSIBLE WALL OUTLET - 18" A.F.F
BATHROOM VANITY OUTLET - 42" A.F.F
TYP. KITCHEN OUTLET - 42" A.F.F
ADA KITCHEN OUTLET - 46" A.F.F
ADA BATHROOM VANITY OUTLET - 44" A.F.F
ELECTRICAL SWITCH HEIGHTS (U.N.O)
SWITCH - 44" A.F.F
THERMOSTAT REMOTE - 48" A.F.F MAX TO TOP OF SWITCH
SD
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216UNIT INT. ELEVATIONS -KING 1-BR ADAMOBILITY
A-418B
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
FFL
FFL
FFL
1/2" = 1'-0" Reference: 1 / A-418
1KING ADA 1-BEDROOM ELEVATION A
Room 301
1/2" = 1'-0" Reference: 1 / A-413
2 KING ADA 1-BEDROOM ELEVATION B
Room 301
1/2" = 1'-0" Reference: 1 / A-418
3KING ADA 1-BEDROOM ELEVATION C
Room 301 1/2" = 1'-0" Reference: 1 / A-413
4 KING ADA 1-BEDROOM ELEVATION D
Room 301
1/2" = 1'-0" Reference: 1 / A-418
6KING ADA 1-BEDROOM ELEVATION A2
Room 301
1/2" = 1'-0" Reference: 1 / A-418
7KING ADA 1-BEDROOM ELEVATION B2
Room 301
1/2" = 1'-0" Reference: 1 / A-418
8 KING ADA 1-BEDROOM ELEVATION C2
Room 301
1/2" = 1'-0" Reference: 1 / A-418
9KING ADA 1-BEDROOM ELEVATION D2
Room 301
FFL
1/2" = 1'-0" Reference: 1 / A-418
5KING ADA 1-BEDROOM ELEVATION D3
Room 301
FURNISHING SCHEDULE
GUESTROOM FURNISHINGS
GR-100 CHAIR - LOUNGE CHAIR WITH OTTOMAN
GR-101 CHAIR - LOUNGE CHAIR IN STUIDOS
GR-102 CHAIR - COUNTER HEIGHT DESK CHAIR
GR-103 CHAIR - KITCHEN STOOL
FURNISHING SCHEDULE
GR-105 SOFA - SLEEP BETWEEN ARMS
GR-200 SCONCE - PIN-UP
GR-201 SCONCE - NIGHTSTAND
GR-203 PENDANT LIGHT - PRODUCTIVITY TABLE
GR-204 CEILING LIGHT - 1-BEDROOM SUITE
GR-205 LAMP - FLOOR LAMP
GR-308 NIGHTSTAND - REGULAR
GR-310 DESK - EFFICIENCY
GR-312 TABLE - NESTING
GR-313 TABLE - ROUND SIDE TABLE
GR-314 TABLE - PRODUCTIVITY TABLE (STUDIO)
GR-316 CONSOLE - LIVING ROOM (1-BEDROOM)
FURNISHING SCHEDULE
GR-317 DRESSER - BEDROOM (1-BEDROOM)
GR-319 CLOSET - EFFICIENCY SUITE
GR-324 CLOSET - ACCESSIBLE KING 1-BEDROOM SUITE
GR-327 VANITY - ACCESSIBLE SUITES
GR-328 BATH CADDY - ACCESSIBLE SUITES
GR-400 STATIC DRAPARY PANELS
GR-403 ROLLER SHADE - GUESTROOMS (MANUAL,SHEER/BLACK-OUT, 8' W)
GR-405 ROLLER SHADE - GUESTROOMS (MANUAL,SHEER/BLACK-OUT, 8' W)
GR-410 VALENCE FOR 5' WINDOW
GR-413 VALENCE FOR 5' WINDOW - ONE DRAPERYPANEL
KEYNOTES - UNIT PLANS
1 ALIGN
2 GENERAL CONTRACTOR TO COORDINATE W/ FURNITUREFABRICATOR WHERE NECESSARY TO PROVIDE PROPERBLOCKING IN WALL FOR ITEM KEYNOTED
3 NO FINISHES UNDER THE SHOWER PAN / TUB
4 NO FINISHES UNDER MILLWORK CABINETRY
5 TV AND MOUNT NOT TO PROJECT MORE THAN 4" FROMWALL
6 MOTORIZED BLINDS. PROVIDE JUNCTION BOX BEHINDVALENCE FOR POWER CONNECTION AND PERMANENTLYINSTALLED SWITCH ON WALL TO CONTROL BLINDS.
7 SWITCH CONTROLLING UNDER CABINET LIGHTING ATKITCHEN TO BE GANGED WITH LIGHTING AT ENTRY
8 SWITCH CONTROLLING GARBAGE DISPOSAL-REFER TOHADG FOR ACCESSIBLE ROOM REQ'S.
9 DEDICATED CIRCUIT FOR GARBAGE DISPOSAL
10 MASTER SWITCH
11 DEDICATED CIRCUIT FOR INDUCTION COOKTOP
12 DEDICATED CIRCUIT FOR DISHWASHER
13 DEDICATED CIRCUIT FOR REFRIGERATOR
14 ELECTRIC VANITY MIRROR - HARDWIRE FIXTURE TO WALL-CONTRACTOR TO VERIFY JBOX TYPE TO ENSURE PROPERINSTALLATION AND BACKING FOR ITEM KEYNOTED
15 DOORBELL AND DOORBELL ON/OFF SWITCH(COMMUNICATION FEATURES ROOMS ONLY)SIGNAGE ASREQ'D.
16 PLACE TV OUTLETS AND CONNECTIONS ON WALL OUTSIDEAREA OF BRACKET AND CONCEALED FROM VIEW BY TV
17 DEDICATED CIRCUIT FOR WASHER/DRYER. DIRECT VENTTO EXTERIOR
FURNISHING SCHEDULE
GR-503 ART- ENTRY
GR-504 ART- SLEEPING/LIVING
GR-505 WALL HOOK
GR-507 MIRROR - ADA VANITY
GR-508 MIRROR - GUESTROOM VANITY
GR-800 KITCHENETTE - 1-BEDROOM
GR-802 KITCHENETTE - EFFICIENCY SUITE
GR-803 KITCHENETTE - ONE BEDROOM SUITE
GR-900 GUESTROOM REFRIGERATOR
GR-901 GUESTROOM DISHWASHER
GR-902 GUESTROOM COOKTOP - 2 BURNER
GR-903 GUESTROOM COOKTOP - 4 BURNER
GR-904 GARBAGE DISPOSAL 1/3HP
GR-905 MICROWAVE- WITH RECIRCULATING HOOD
GR-906GR-911 TELEVISION & TELEVISION MOUNT
GR-907 CLOCK/RADIO
GR-908 TELEPHONE - GUESTROOM
GR-909 GUESTROOM WASHING MACHINE
GR-910 GUESTROOM DRYER
GR-913 COUNTERTOP MICROWAVE
GR-ES BED - EFFICIENCY (GR-300, 303, 600)
GR-KM BED - KING MOBILITY (GR-301, 304, 600, 602)
HILTON SPECIFIED - OWNER FURNISHED
OF-702A CHAIR - BALCONY CHAIR
OF-705 TABLE - 17" D OUTDOOR SIDE TABLE
OWNER SPECIFIED - OWNER FURNISHED
OP-706 FIRE EXTINGUISHER CABINET
FURNISHING SCHEDULE
PLUMBING/MECHANICAL FIXTURES
PF-01 TOILET - GUESTROOM
PF-03 SHOWER BASE - 60" X 36" WITH LINEAR DRAIN
PF-06 BATHTUB - 5' X 32" WITH SIDE LEDGE
PF-07 LAVATORY - UNDERMOUNT, 20" X 14"
PF-10 SHOWER HEAD - HIGH
PF-12 SHOWER HEAD - HAND HELD ON SLIDE BAR
PF-13 SHOWER/TUB VALVE & CONTROL
PF-14 BATHTUB FILL FAUCET
PF-15 FAUCET - LAVATORY
PF-40 SINK - KITCHENETTE
PF-41 FAUCET - KITCHENETTE
TOILET ACCESSORIES
HD-02 DUAL TOILET PAPER HOLDER- ADA
HD-04 WALL-MOUNTED ROBE HOOK
HD-04.1 TOWEL BAR
HD-05 CURVED CURTAIN ROD AND SHOWER CURTAIN
HD-05.2 SLIDING SHOWER DOOR
HD-08 18" GRAB BAR
HD-09 24" GRAB BAR
HD-10 42" GRAB BAR AT ADA BATHTUB
HD-11 36" GRAB BAR
HD-11.1 42" GRAB BAR
HD-14.1 ROLL-IN SHOWER SEAT
HD-16 BULK AMENITY DISPENSER AT SHOWERS/TUBS
HD-18 FOOT LEDGE FOR SHOWER
HD-18.1 SOAP SHELF
HD-20 12" GRAB BAR
HD-21 BULK AMENITY DISPENSER AT LAVATORIES
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
Revision Schedule
Number Description Date
W/DW/DM
A
A
M
SD
SD
SD
SD
TV
TV
58 SF
BALCONY
201A
A-419B2
1
4
3
A-419B
6
7
8
9
P3.1
P2.1
D-G05
P1.1
P1.2
D-G03
D-G03
D-G04
D-G01
7' - 0"
12' - 10 1/4"14' - 7 3/4"7' - 5 1/4"6' - 6 1/2"15' - 9 1/4"
2' - 11"
D-G02A2' - 0 1/2"2' - 10 3/4"2' - 1 1/4"GR-312
GR-108
GR-205
GR-316
11' - 9"
4' - 9"
GR-906GR-911
GR-323
GR-326
GR-900
GR-903
GR-901
GR-103
GR-103GR-103
GR-103
GR-ES
GR-317
GR-906GR-911
GR-308
GR-308
GR-201
GR-201
GR-508
GR-504
GR-503
GR-908
GR-90712' - 7"GR-400GR-400
A-419B5
GR-506
GR-315
GR-909/910
GR-800
0' - 3"GR-400
GR-400
PF-40
PF-41
OF-702A
OF-702A
OF-705
A-425
1
GR-410GR-400 GR-400
CL-B8' - 0"
CL-B8' - 0"
CL-B8' - 0"
1' - 0"1' - 0"
1
1
1
1
1
1
1
EQ EQ
3' - 2 3/4"3' - 3 1/4"4' - 0"4' - 0"
EQ1' - 0"1' - 4"1' - 3"1' - 3"3' - 1"EQEQ2' - 2"EQ
1' - 5"2' - 1"
EQ1' - 5"A-425
3 Sim
PLANELEV
DUPLEX OUTLET
QUADPLEX OUTLET
GFCI OUTLET
CAT6, RJ45 INTERNET OUTLET
TELEPHONE OUTLET
WALL MOUNTED WIRELESS THERMOSTAT
POWER OUTLET WITH USB PORTS
CATV OUTLET
ELECTRICAL SWITCH
FLOOR OUTLET
POWER AND SIGNAL LEGEND:
POWER SUPPLY
JUNCTION BOX
DOOR BELL HARDWIRED TO DOORBELL LIGHT - MOUNT @ 46" A.F.F TO CENTER OF BUTTON (FOR COMMUNICATIONS FEATURES ROOMS ONLY)
CEILING FIXTURE LEGEND:
6" RECESSED CAN DOWNLIGHT
DECORATIVE FLUSH MOUNT LIGHT
PENDENT TYPE SPRINKLERS
SMOKE DETECTOR
EXHAUST FAN / GRILLE
LINEAR SURFACE MOUNTED CONTINUOUS LED SYSTEM W/ FIXED MOUNTING CLIPS & FROSTED LENS / 3 WATTS PER FOOT, MLV/FWD
ELECTRICAL OUTLET HEIGHTS (U.N.O)
TYPICAL OUTLET - 15" A.F.F
TYPICAL ACCESSIBLE WALL OUTLET - 18" A.F.F
BATHROOM VANITY OUTLET - 42" A.F.F
TYP. KITCHEN OUTLET - 42" A.F.F
ADA KITCHEN OUTLET - 46" A.F.F
ADA BATHROOM VANITY OUTLET - 44" A.F.F
ELECTRICAL SWITCH HEIGHTS (U.N.O)
SWITCH - 44" A.F.F
THERMOSTAT REMOTE - 48" A.F.F MAX TO TOP OF SWITCH
SD
1/2" = 1'-0"2 KING 1-BEDROOM ENLARGED REFLECTED CEILING PLAN
Units 201, 401, 501
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216UNIT PLAN - KING1-BEDROOM ENLARGED
A-419
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
1/2" = 1'-0" Reference: 1 / A-102
1KING 1-BEDROOM ENLARGED CONSTRUCTION PLAN
Units 201, 401, 501
0'1' 2'4'
SCALE: 1/2" = 1'-0"
2
5
2
2
5
2
2
2
FURNISHING SCHEDULE
GUESTROOM FURNISHINGS
GR-100 CHAIR - LOUNGE CHAIR WITH OTTOMAN
GR-103 CHAIR - KITCHEN STOOL
GR-108 SOFA - SECTIONAL SLEEPER
GR-200 SCONCE - PIN-UP
GR-201 SCONCE - NIGHTSTAND
GR-203 PENDANT LIGHT - PRODUCTIVITY TABLE
GR-204 CEILING LIGHT - 1-BEDROOM SUITE
GR-205 LAMP - FLOOR LAMP
GR-308 NIGHTSTAND - REGULAR
GR-312 TABLE - NESTING
GR-315 TABLE - PRODUCTIVITY TABLE(1-BEDROOM)
GR-316 CONSOLE - LIVING ROOM (1-BEDROOM)
GR-317 DRESSER - BEDROOM (1-BEDROOM)
GR-323 CLOSET - KING 1-BEDROOM SUITE
GR-326 VANITY - STUDIO AND 1-BEDROOM SUITES
GR-400 STATIC DRAPARY PANELS
GR-403 ROLLER SHADE - GUESTROOMS (MANUAL,SHEER/BLACK-OUT, 8' W)
GR-410 VALENCE FOR 5' WINDOW
FURNISHING SCHEDULE
GR-411 VALENCE FOR 5' WINDOW - ONE DRAPERYPANEL
GR-503 ART- ENTRY
GR-504 ART- SLEEPING/LIVING
GR-505 WALL HOOK
GR-506 MIRROR - GUESTROOM FULL LENGTH
GR-508 MIRROR - GUESTROOM VANITY
GR-800 KITCHENETTE - 1-BEDROOM
GR-802 KITCHENETTE - EFFICIENCY SUITE
GR-900 GUESTROOM REFRIGERATOR
GR-901 GUESTROOM DISHWASHER
GR-902 GUESTROOM COOKTOP - 2 BURNER
GR-903 GUESTROOM COOKTOP - 4 BURNER
GR-904 GARBAGE DISPOSAL 1/3HP
GR-905 MICROWAVE- WITH RECIRCULATING HOOD
GR-906GR-911 TELEVISION & TELEVISION MOUNT
GR-907 CLOCK/RADIO
GR-908 TELEPHONE - GUESTROOM
GR-909/910 GUESTROOM STACKED WASHER/DRYER
FURNISHING SCHEDULE
GR-ES BED - EFFICIENCY (GR-300, 303, 600)
HILTON SPECIFIED - OWNER FURNISHED
OF-702A CHAIR - BALCONY CHAIR
OF-705 TABLE - 17" D OUTDOOR SIDE TABLE
PLUMBING/MECHANICAL FIXTURES
PF-01 TOILET - GUESTROOM
PF-03 SHOWER BASE - 60" X 36" WITH LINEARDRAIN
PF-06 BATHTUB - 5' X 32" WITH SIDE LEDGE
PF-07 LAVATORY - UNDERMOUNT, 20" X 14"
PF-11 SHOWER HEAD - 2 IN 1
PF-13 SHOWER/TUB VALVE & CONTROL
PF-15 FAUCET - LAVATORY
PF-40 SINK - KITCHENETTE
PF-41 FAUCET - KITCHENETTE
TOILET ACCESSORIES
KEYNOTES - UNIT PLANS
1 ALIGN
2 GENERAL CONTRACTOR TO COORDINATE W/ FURNITUREFABRICATOR WHERE NECESSARY TO PROVIDE PROPERBLOCKING IN WALL FOR ITEM KEYNOTED
3 NO FINISHES UNDER THE SHOWER PAN / TUB
4 NO FINISHES UNDER MILLWORK CABINETRY
5 TV AND MOUNT NOT TO PROJECT MORE THAN 4" FROMWALL
6 MOTORIZED BLINDS. PROVIDE JUNCTION BOX BEHINDVALENCE FOR POWER CONNECTION AND PERMANENTLYINSTALLED SWITCH ON WALL TO CONTROL BLINDS.
7 SWITCH CONTROLLING UNDER CABINET LIGHTING ATKITCHEN TO BE GANGED WITH LIGHTING AT ENTRY
8 SWITCH CONTROLLING GARBAGE DISPOSAL-REFER TOHADG FOR ACCESSIBLE ROOM REQ'S.
9 DEDICATED CIRCUIT FOR GARBAGE DISPOSAL
10 MASTER SWITCH
11 DEDICATED CIRCUIT FOR INDUCTION COOKTOP
12 DEDICATED CIRCUIT FOR DISHWASHER
13 DEDICATED CIRCUIT FOR REFRIGERATOR
14 ELECTRIC VANITY MIRROR - HARDWIRE FIXTURE TO WALL-CONTRACTOR TO VERIFY JBOX TYPE TO ENSURE PROPERINSTALLATION AND BACKING FOR ITEM KEYNOTED
15 DOORBELL AND DOORBELL ON/OFF SWITCH(COMMUNICATION FEATURES ROOMS ONLY)SIGNAGE ASREQ'D.
16 PLACE TV OUTLETS AND CONNECTIONS ON WALL OUTSIDEAREA OF BRACKET AND CONCEALED FROM VIEW BY TV
17 DEDICATED CIRCUIT FOR WASHER/DRYER. DIRECT VENTTO EXTERIOR
FURNISHING SCHEDULE
HD-01 DUAL TOILET PAPER HOLDER
HD-04 WALL-MOUNTED ROBE HOOK
HD-04.1 TOWEL BAR
HD-05.2 SLIDING SHOWER DOOR
HD-08 18" GRAB BAR
HD-16 BULK AMENITY DISPENSER ATSHOWERS/TUBS
HD-18 FOOT LEDGE FOR SHOWER
HD-18.1 SOAP SHELF
HD-21 BULK AMENITY DISPENSER AT LAVATORIES
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
Revision Schedule
Number Description Date
W/DTV
TV
A-419B2
1
4
3
A-419B
6
7
8
9
A-419B5
WC-01
WC-01
WC-01
WC-01 WC-01
WC-01
WC-01
WC-01
SF-01
SF-01SF-01
WC-01WC-01
EQEQFULL TILEFULL TILE
CT-01
RES-01
CPT-01
6
A-510
Sim
8
A-510
Sim
9
A-510
Sim
7
A-510
Sim
PLANELEV
DUPLEX OUTLET
QUADPLEX OUTLET
GFCI OUTLET
CAT6, RJ45 INTERNET OUTLET
TELEPHONE OUTLET
WALL MOUNTED WIRELESS THERMOSTAT
POWER OUTLET WITH USB PORTS
CATV OUTLET
ELECTRICAL SWITCH
FLOOR OUTLET
POWER AND SIGNAL LEGEND:
POWER SUPPLY
JUNCTION BOX
DOOR BELL HARDWIRED TO DOORBELL LIGHT - MOUNT @ 46" A.F.F TO CENTER OF BUTTON (FOR COMMUNICATIONS FEATURES ROOMS ONLY)
CEILING FIXTURE LEGEND:
6" RECESSED CAN DOWNLIGHT
DECORATIVE FLUSH MOUNT LIGHT
PENDENT TYPE SPRINKLERS
SMOKE DETECTOR
EXHAUST FAN / GRILLE
LINEAR SURFACE MOUNTED CONTINUOUS LED SYSTEM W/ FIXED MOUNTING CLIPS & FROSTED LENS / 3 WATTS PER FOOT, MLV/FWD
ELECTRICAL OUTLET HEIGHTS (U.N.O)
TYPICAL OUTLET - 15" A.F.F
TYPICAL ACCESSIBLE WALL OUTLET - 18" A.F.F
BATHROOM VANITY OUTLET - 42" A.F.F
TYP. KITCHEN OUTLET - 42" A.F.F
ADA KITCHEN OUTLET - 46" A.F.F
ADA BATHROOM VANITY OUTLET - 44" A.F.F
ELECTRICAL SWITCH HEIGHTS (U.N.O)
SWITCH - 44" A.F.F
THERMOSTAT REMOTE - 48" A.F.F MAX TO TOP OF SWITCH
SD
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216UNIT PLAN - KING1-BEDROOM ENLARGED- ELEC, DATA & FLOORFINISH PLAN
A-419A
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
0'1' 2'4'
SCALE: 1/2" = 1'-0"
1/2" = 1'-0" Reference: 1 / A-123
1KING 1-BEDROOM ENLARGED ELECTRICAL & DATA PLAN
Units 201, 401, 501
1/2" = 1'-0"2 KING 1-BEDROOM ENLARGED FLOOR & WALL FINISH PLAN
Units 201, 401, 501
3
7
12
8
9
11
13
15
10
17
16
16
FURNISHING SCHEDULE
GUESTROOM FURNISHINGS
GR-103 CHAIR - KITCHEN STOOL
GR-108 SOFA - SECTIONAL SLEEPER
GR-201 SCONCE - NIGHTSTAND
GR-205 LAMP - FLOOR LAMP
GR-308 NIGHTSTAND - REGULAR
GR-312 TABLE - NESTING
GR-315 TABLE - PRODUCTIVITY TABLE(1-BEDROOM)
GR-316 CONSOLE - LIVING ROOM (1-BEDROOM)
GR-317 DRESSER - BEDROOM (1-BEDROOM)
GR-323 CLOSET - KING 1-BEDROOM SUITE
GR-326 VANITY - STUDIO AND 1-BEDROOM SUITES
GR-400 STATIC DRAPARY PANELS
GR-503 ART- ENTRY
GR-504 ART- SLEEPING/LIVING
GR-506 MIRROR - GUESTROOM FULL LENGTH
GR-508 MIRROR - GUESTROOM VANITY
GR-800 KITCHENETTE - 1-BEDROOM
GR-900 GUESTROOM REFRIGERATOR
GR-901 GUESTROOM DISHWASHER
GR-903 GUESTROOM COOKTOP - 4 BURNER
GR-904 GARBAGE DISPOSAL 1/3HP
GR-906GR-911 TELEVISION & TELEVISION MOUNT
GR-907 CLOCK/RADIO
FURNISHING SCHEDULE
GR-908 TELEPHONE - GUESTROOM
GR-909/910 GUESTROOM STACKED WASHER/DRYER
GR-ES BED - EFFICIENCY (GR-300, 303, 600)
PLUMBING/MECHANICAL FIXTURES
PF-01 TOILET - GUESTROOM
PF-03 SHOWER BASE - 60" X 36" WITH LINEARDRAIN
PF-07 LAVATORY - UNDERMOUNT, 20" X 14"
PF-11 SHOWER HEAD - 2 IN 1
PF-13 SHOWER/TUB VALVE & CONTROL
PF-15 FAUCET - LAVATORY
PF-40 SINK - KITCHENETTE
PF-41 FAUCET - KITCHENETTE
TOILET ACCESSORIES
HD-01 DUAL TOILET PAPER HOLDER
HD-04.1 TOWEL BAR
HD-05.2 SLIDING SHOWER DOOR
HD-08 18" GRAB BAR
HD-16 BULK AMENITY DISPENSER ATSHOWERS/TUBS
HD-18 FOOT LEDGE FOR SHOWER
HD-18.1 SOAP SHELF
HD-21 BULK AMENITY DISPENSER AT LAVATORIES
KEYNOTES - UNIT PLANS
1 ALIGN
2 GENERAL CONTRACTOR TO COORDINATE W/ FURNITUREFABRICATOR WHERE NECESSARY TO PROVIDE PROPERBLOCKING IN WALL FOR ITEM KEYNOTED
3 NO FINISHES UNDER THE SHOWER PAN / TUB
4 NO FINISHES UNDER MILLWORK CABINETRY
5 TV AND MOUNT NOT TO PROJECT MORE THAN 4" FROMWALL
6 MOTORIZED BLINDS. PROVIDE JUNCTION BOX BEHINDVALENCE FOR POWER CONNECTION AND PERMANENTLYINSTALLED SWITCH ON WALL TO CONTROL BLINDS.
7 SWITCH CONTROLLING UNDER CABINET LIGHTING ATKITCHEN TO BE GANGED WITH LIGHTING AT ENTRY
8 SWITCH CONTROLLING GARBAGE DISPOSAL-REFER TOHADG FOR ACCESSIBLE ROOM REQ'S.
9 DEDICATED CIRCUIT FOR GARBAGE DISPOSAL
10 MASTER SWITCH
11 DEDICATED CIRCUIT FOR INDUCTION COOKTOP
12 DEDICATED CIRCUIT FOR DISHWASHER
13 DEDICATED CIRCUIT FOR REFRIGERATOR
14 ELECTRIC VANITY MIRROR - HARDWIRE FIXTURE TO WALL-CONTRACTOR TO VERIFY JBOX TYPE TO ENSURE PROPERINSTALLATION AND BACKING FOR ITEM KEYNOTED
15 DOORBELL AND DOORBELL ON/OFF SWITCH(COMMUNICATION FEATURES ROOMS ONLY)SIGNAGE ASREQ'D.
16 PLACE TV OUTLETS AND CONNECTIONS ON WALL OUTSIDEAREA OF BRACKET AND CONCEALED FROM VIEW BY TV
17 DEDICATED CIRCUIT FOR WASHER/DRYER. DIRECT VENTTO EXTERIOR
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
Revision Schedule
Number Description Date
TV
SF-01
RB-01
WC-01
W-K
PT-03PT-03
GR-403
GR-411GR-400GR-323
D-G04
GR-203
D-G05
SF-01
RB-01
W-H
WD-01
GFCI
GR-403
GR-403
GR-203
GR-400 GR-410
0' - 9"
4' - 6 3/4"
PT-03PL-02
2' - 2 1/4"
RB-01
WC-01WC-01
RB-10PT-03PL-02
GR-505
5' - 0"0' - 6 1/2"
0' - 8"5' - 1"4' - 2"GR-403
D-G03D-G02A
1' - 6"1' - 1"5' - 1 3/4"4' - 6"PT-11 PL-01
WC-01
RB-01 RB-10
WC-01
D-G01
GR-503
W-H
SF-01
RB-01
GR-410
16
A-510
Sim
GR-400
GR-403
WC-01
RB-01
GR-403
GR-ESGR-201
GR-308
PT-03 PT-035' - 0"EQEQ
RB-01
WC-01
D-G05
GR-504
6' - 0 1/2"
RB-01
WC-01
GR-317
GR-906GR-911
GR-505
5' - 0"WC-01
RB-01
D-G01
PLANELEV
DUPLEX OUTLET
QUADPLEX OUTLET
GFCI OUTLET
CAT6, RJ45 INTERNET OUTLET
TELEPHONE OUTLET
WALL MOUNTED WIRELESS THERMOSTAT
POWER OUTLET WITH USB PORTS
CATV OUTLET
ELECTRICAL SWITCH
FLOOR OUTLET
POWER AND SIGNAL LEGEND:
POWER SUPPLY
JUNCTION BOX
DOOR BELL HARDWIRED TO DOORBELL LIGHT - MOUNT @ 46" A.F.F TO CENTER OF BUTTON (FOR COMMUNICATIONS FEATURES ROOMS ONLY)
CEILING FIXTURE LEGEND:
6" RECESSED CAN DOWNLIGHT
DECORATIVE FLUSH MOUNT LIGHT
PENDENT TYPE SPRINKLERS
SMOKE DETECTOR
EXHAUST FAN / GRILLE
LINEAR SURFACE MOUNTED CONTINUOUS LED SYSTEM W/ FIXED MOUNTING CLIPS & FROSTED LENS / 3 WATTS PER FOOT, MLV/FWD
ELECTRICAL OUTLET HEIGHTS (U.N.O)
TYPICAL OUTLET - 15" A.F.F
TYPICAL ACCESSIBLE WALL OUTLET - 18" A.F.F
BATHROOM VANITY OUTLET - 42" A.F.F
TYP. KITCHEN OUTLET - 42" A.F.F
ADA KITCHEN OUTLET - 46" A.F.F
ADA BATHROOM VANITY OUTLET - 44" A.F.F
ELECTRICAL SWITCH HEIGHTS (U.N.O)
SWITCH - 44" A.F.F
THERMOSTAT REMOTE - 48" A.F.F MAX TO TOP OF SWITCH
SD
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216UNIT INT. ELEVATIONS -KING 1-BEDROOMENLARGED
A-419B
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
FFL
FFL
FFL
1/2" = 1'-0" Reference: 1 / A-419
1KING 1-BEDROOM ENLARGED ELEV. A
Entry and Kitchen/Dining
1/2" = 1'-0" Reference: 1 / A-419
2 KING 1-BEDROOM ENLARGED ELEV. B
Kitchen/Dining and Living
1/2" = 1'-0" Reference: 1 / A-419
3KING 1-BEDROOM ENLARGED ELEV. C
Living and Entry
1/2" = 1'-0" Reference: 1 / A-419
4 KING 1-BEDROOM ENLARGED ELEV. D
Living and Kitchen/Dining
FFL
1/2" = 1'-0" Reference: 1 / A-419
6KING 1-BEDROOM ENLARGED ELEV. A2
Bedroom
1/2" = 1'-0" Reference: 1 / A-419
7KING 1-BEDROOM ENLARGED ELEV. B2
Bedroom
1/2" = 1'-0" Reference: 1 / A-419
8 KING 1-BEDROOM ENLARGED ELEV. C2
Bedroom
1/2" = 1'-0" Reference: 1 / A-419
9KING 1-BEDROOM ENLARGED ELEV. D2
Bedroom
1/2" = 1'-0" Reference: 1 / A-419
5KING 1-BEDROOM ENLARGED ELEV. D3
Entry Door
0'1' 2'4'
SCALE: 1/2" = 1'-0"
FURNISHING SCHEDULE
GUESTROOM FURNISHINGS
GR-100 CHAIR - LOUNGE CHAIR WITH OTTOMAN
GR-102 CHAIR - COUNTER HEIGHT DESK CHAIR
GR-103 CHAIR - KITCHEN STOOL
GR-200 SCONCE - PIN-UP
GR-201 SCONCE - NIGHTSTAND
GR-203 PENDANT LIGHT - PRODUCTIVITY TABLE
GR-204 CEILING LIGHT - 1-BEDROOM SUITE
GR-205 LAMP - FLOOR LAMP
GR-308 NIGHTSTAND - REGULAR
GR-310 DESK - EFFICIENCY
FURNISHING SCHEDULE
GR-313 TABLE - ROUND SIDE TABLE
GR-315 TABLE - PRODUCTIVITY TABLE (1-BEDROOM)
GR-316 CONSOLE - LIVING ROOM (1-BEDROOM)
GR-317 DRESSER - BEDROOM (1-BEDROOM)
GR-319 CLOSET - EFFICIENCY SUITE
GR-323 CLOSET - KING 1-BEDROOM SUITE
GR-326 VANITY - STUDIO AND 1-BEDROOM SUITES
GR-400 STATIC DRAPARY PANELS
GR-403 ROLLER SHADE - GUESTROOMS (MANUAL,SHEER/BLACK-OUT, 8' W)
KEYNOTES - UNIT PLANS
1 ALIGN
2 GENERAL CONTRACTOR TO COORDINATE W/ FURNITUREFABRICATOR WHERE NECESSARY TO PROVIDE PROPERBLOCKING IN WALL FOR ITEM KEYNOTED
3 NO FINISHES UNDER THE SHOWER PAN / TUB
4 NO FINISHES UNDER MILLWORK CABINETRY
5 TV AND MOUNT NOT TO PROJECT MORE THAN 4" FROMWALL
6 MOTORIZED BLINDS. PROVIDE JUNCTION BOX BEHINDVALENCE FOR POWER CONNECTION AND PERMANENTLYINSTALLED SWITCH ON WALL TO CONTROL BLINDS.
7 SWITCH CONTROLLING UNDER CABINET LIGHTING ATKITCHEN TO BE GANGED WITH LIGHTING AT ENTRY
8 SWITCH CONTROLLING GARBAGE DISPOSAL-REFER TOHADG FOR ACCESSIBLE ROOM REQ'S.
9 DEDICATED CIRCUIT FOR GARBAGE DISPOSAL
10 MASTER SWITCH
11 DEDICATED CIRCUIT FOR INDUCTION COOKTOP
12 DEDICATED CIRCUIT FOR DISHWASHER
13 DEDICATED CIRCUIT FOR REFRIGERATOR
14 ELECTRIC VANITY MIRROR - HARDWIRE FIXTURE TO WALL-CONTRACTOR TO VERIFY JBOX TYPE TO ENSURE PROPERINSTALLATION AND BACKING FOR ITEM KEYNOTED
15 DOORBELL AND DOORBELL ON/OFF SWITCH(COMMUNICATION FEATURES ROOMS ONLY)SIGNAGE ASREQ'D.
16 PLACE TV OUTLETS AND CONNECTIONS ON WALL OUTSIDEAREA OF BRACKET AND CONCEALED FROM VIEW BY TV
17 DEDICATED CIRCUIT FOR WASHER/DRYER. DIRECT VENTTO EXTERIOR
FURNISHING SCHEDULE
GR-410 VALENCE FOR 5' WINDOW
GR-411 VALENCE FOR 5' WINDOW - ONE DRAPERYPANEL
GR-503 ART- ENTRY
GR-504 ART- SLEEPING/LIVING
GR-505 WALL HOOK
GR-506 MIRROR - GUESTROOM FULL LENGTH
GR-508 MIRROR - GUESTROOM VANITY
GR-800 KITCHENETTE - 1-BEDROOM
GR-802 KITCHENETTE - EFFICIENCY SUITE
GR-900 GUESTROOM REFRIGERATOR
GR-901 GUESTROOM DISHWASHER
GR-902 GUESTROOM COOKTOP - 2 BURNER
GR-903 GUESTROOM COOKTOP - 4 BURNER
GR-904 GARBAGE DISPOSAL 1/3HP
GR-905 MICROWAVE- WITH RECIRCULATING HOOD
GR-906GR-911 TELEVISION & TELEVISION MOUNT
GR-907 CLOCK/RADIO
GR-908 TELEPHONE - GUESTROOM
GR-909/910 GUESTROOM STACKED WASHER/DRYER
GR-ES BED - EFFICIENCY (GR-300, 303, 600)
GR-KS BED - KING (GR-301, 303, 600)
HILTON SPECIFIED - OWNER FURNISHED
OF-702A CHAIR - BALCONY CHAIR
OF-705 TABLE - 17" D OUTDOOR SIDE TABLE
FURNISHING SCHEDULE
OWNER SPECIFIED - OWNER FURNISHED
OP-706 FIRE EXTINGUISHER CABINET
PLUMBING/MECHANICAL FIXTURES
PF-01 TOILET - GUESTROOM
PF-03 SHOWER BASE - 60" X 36" WITH LINEAR DRAIN
PF-07 LAVATORY - UNDERMOUNT, 20" X 14"
PF-11 SHOWER HEAD - 2 IN 1
PF-13 SHOWER/TUB VALVE & CONTROL
PF-15 FAUCET - LAVATORY
PF-40 SINK - KITCHENETTE
PF-41 FAUCET - KITCHENETTE
TOILET ACCESSORIES
HD-01 DUAL TOILET PAPER HOLDER
HD-04 WALL-MOUNTED ROBE HOOK
HD-04.1 TOWEL BAR
HD-05.2 SLIDING SHOWER DOOR
HD-08 18" GRAB BAR
HD-16 BULK AMENITY DISPENSER AT SHOWERS/TUBS
HD-18 FOOT LEDGE FOR SHOWER
HD-18.1 SOAP SHELF
HD-21 BULK AMENITY DISPENSER AT LAVATORIES
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
Revision Schedule
Number Description Date
MMAASD
TVTV
A-420B2
1
4
3
D-G02
GR-908
GR-907
D-G026' - 9 3/4"6' - 9 3/4"29' - 5 1/2"6' - 1"
D-G01
D-G03
D-G03
W-G
GR-QS
GR-QS
GR-307
GR-308
GR-201
GR-206
GR-307
GR-206
GR-908
GR-907
GR-103
GR-103
GR-318
GR-312
GR-101
GR-205
GR-313
GR-105
GR-326
GR-906GR-911
18' - 5"
GR-400GR-400
GR-201
GR-321
GR-506
ALIGN
GR-314
GR-504
GR-508
P3.1
A-4252
OF-705OF-702AOF-702A
CL-B8' - 0"
GR-412 GR-400GR-400
CL-B27' - 6"
CL-A8' - 0"
CL-B27' - 6"EQEQ3' - 2"
1
1
1
GR-203
GR-203
1
1
1
1 1
EQ EQ
EQ EQ
7' - 7"5' - 2"1' - 5"8' - 4 1/4"
5' - 6"3' - 8 3/4"
OF-702
OF-705
OF-702
PLAN ELEV
DUPLEX OUTLET
QUADPLEX OUTLET
GFCI OUTLET
CAT6, RJ45 INTERNET OUTLET
TELEPHONE OUTLET
WALL MOUNTED WIRELESS THERMOSTAT
POWER OUTLET WITH USB PORTS
CATV OUTLET
ELECTRICAL SWITCH
FLOOR OUTLET
POWER AND SIGNAL LEGEND:
POWER SUPPLY
CEILING FIXTURE LEGEND:
6" RECESSED CAN DOWNLIGHT
DECORATIVE FLUSH MOUNT LIGHT
PENDENT TYPE SPRINKLERS
SMOKE DETECTOR
EXHAUST FAN / GRILLE
LINEAR SURFACE MOUNTED CONTINUOUS LED SYSTEM W/ FIXED MOUNTING CLIPS & FROSTED LENS / 3 WATTS PER FOOT, MLV/FWD
ELECTRICAL OUTLET HEIGHTS (U.N.O)
TYPICAL OUTLET - 15" A.F.F
TYPICAL ACCESSIBLE WALL OUTLET - 18" A.F.F
BATHROOM VANITY OUTLET - 42" A.F.F
TYP. KITCHEN OUTLET - 42" A.F.F
ADA KITCHEN OUTLET - 46" A.F.F
ADA BATHROOM VANITY OUTLET - 44" A.F.F
ELECTRICAL SWITCH HEIGHTS (U.N.O)
SWITCH - 44" A.F.F
THERMOSTAT REMOTE - 48" A.F.F MAX TO TOP OF SWITCH
JUNCTION BOX
DOOR BELL HARDWIRED TO DOORBELL LIGHT - MOUNT @ 46" A.F.F TO CENTER OF BUTTON (FOR COMMUNICATIONS FEATURES ROOMS ONLY)
SD
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216UNIT PLAN - DOUBLEQUEEN STUDIO
A-420
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
1/2" = 1'-0" Reference: 1 / A-102
1DOUBLE QUEEN STUDIO CONSTRUCTION PLAN
Units x10, x22, x24, x35-x36
1/2" = 1'-0" Reference: 1 / A-102
2DOUBLE QUEEN STUDIO BALCONY PLAN
Units 235, 335, 435, 535
1/2" = 1'-0"3DOUBLE QUEEN STUDIO RCP
Units x10, x22, x24, x35-x36
1/2" = 1'-0" Reference: 1 / A-101
4DOUBLE QUEEN STUDIO LANAI PLAN
Unit 135
0'1' 2'4'
SCALE: 1/2" = 1'-0"
2
5
2
2
2
2
KEYNOTES - UNIT PLANS
1 ALIGN
2 GENERAL CONTRACTOR TO COORDINATE W/ FURNITUREFABRICATOR WHERE NECESSARY TO PROVIDE PROPERBLOCKING IN WALL FOR ITEM KEYNOTED
3 NO FINISHES UNDER THE SHOWER PAN / TUB
4 NO FINISHES UNDER MILLWORK CABINETRY
5 TV AND MOUNT NOT TO PROJECT MORE THAN 4" FROMWALL
6 MOTORIZED BLINDS. PROVIDE JUNCTION BOX BEHINDVALENCE FOR POWER CONNECTION AND PERMANENTLYINSTALLED SWITCH ON WALL TO CONTROL BLINDS.
7 SWITCH CONTROLLING UNDER CABINET LIGHTING ATKITCHEN TO BE GANGED WITH LIGHTING AT ENTRY
8 SWITCH CONTROLLING GARBAGE DISPOSAL-REFER TOHADG FOR ACCESSIBLE ROOM REQ'S.
9 DEDICATED CIRCUIT FOR GARBAGE DISPOSAL
10 MASTER SWITCH
11 DEDICATED CIRCUIT FOR INDUCTION COOKTOP
12 DEDICATED CIRCUIT FOR DISHWASHER
13 DEDICATED CIRCUIT FOR REFRIGERATOR
14 ELECTRIC VANITY MIRROR - HARDWIRE FIXTURE TO WALL-CONTRACTOR TO VERIFY JBOX TYPE TO ENSURE PROPERINSTALLATION AND BACKING FOR ITEM KEYNOTED
15 DOORBELL AND DOORBELL ON/OFF SWITCH(COMMUNICATION FEATURES ROOMS ONLY)SIGNAGE ASREQ'D.
16 PLACE TV OUTLETS AND CONNECTIONS ON WALL OUTSIDEAREA OF BRACKET AND CONCEALED FROM VIEW BY TV
17 DEDICATED CIRCUIT FOR WASHER/DRYER. DIRECT VENTTO EXTERIOR
FURNISHING SCHEDULE
GUESTROOM FURNISHINGS
GR-101 CHAIR - LOUNGE CHAIR IN STUIDOS
GR-103 CHAIR - KITCHEN STOOL
GR-105 SOFA - SLEEP BETWEEN ARMS
GR-201 SCONCE - NIGHTSTAND
GR-203 PENDANT LIGHT - PRODUCTIVITY TABLE
GR-205 LAMP - FLOOR LAMP
GR-206 LAMP - DOUBLE QUEEN READING LAMP
GR-307 NIGHTSTAND - SMALL
GR-308 NIGHTSTAND - REGULAR
GR-312 TABLE - NESTING
GR-313 TABLE - ROUND SIDE TABLE
GR-314 TABLE - PRODUCTIVITY TABLE (STUDIO)
GR-318 DRESSER - HIGHBOY
GR-321 CLOSET - KING STUDIO SUITE
GR-326 VANITY - STUDIO AND 1-BEDROOM SUITES
GR-400 STATIC DRAPARY PANELS
GR-402 ROLLER SHADE - GUESTROOMS (MANUAL,SHEER/BLACK-OUT, 5' W)
GR-412 VALENCE FOR 8' WINDOW
GR-502 ART
GR-504 ART- SLEEPING/LIVING
GR-506 MIRROR - GUESTROOM FULL LENGTH
GR-508 MIRROR - GUESTROOM VANITY
GR-800 KITCHENETTE - 1-BEDROOM
GR-900 GUESTROOM REFRIGERATOR
GR-901 GUESTROOM DISHWASHER
GR-902 GUESTROOM COOKTOP - 2 BURNER
GR-904 GARBAGE DISPOSAL 1/3HP
GR-905 MICROWAVE- WITH RECIRCULATING HOOD
GR-906GR-911 TELEVISION & TELEVISION MOUNT
GR-907 CLOCK/RADIO
GR-908 TELEPHONE - GUESTROOM
GR-QS BED - QUEEN (GR-302, 305, 601)
HILTON SPECIFIED - OWNER FURNISHED
OF-702 CHAIR - OUDOOR DINING CHAIR
OF-702A CHAIR - BALCONY CHAIR
OF-705 TABLE - 17" D OUTDOOR SIDE TABLE
OWNER SPECIFIED - OWNER FURNISHED
OP-706 FIRE EXTINGUISHER CABINET
PLUMBING/MECHANICAL FIXTURES
PF-01 TOILET - GUESTROOM
PF-06 BATHTUB - 5' X 32" WITH SIDE LEDGE
PF-07 LAVATORY - UNDERMOUNT, 20" X 14"
PF-11 SHOWER HEAD - 2 IN 1
PF-13 SHOWER/TUB VALVE & CONTROL
PF-14 BATHTUB FILL FAUCET
PF-15 FAUCET - LAVATORY
PF-40 SINK - KITCHENETTE
PF-41 FAUCET - KITCHENETTE
TOILET ACCESSORIES
HD-01 DUAL TOILET PAPER HOLDER
HD-04 WALL-MOUNTED ROBE HOOK
HD-04.1 TOWEL BAR
HD-05 CURVED CURTAIN ROD AND SHOWERCURTAIN
HD-08 18" GRAB BAR
HD-16 BULK AMENITY DISPENSER ATSHOWERS/TUBS
HD-18.1 SOAP SHELF
HD-21 BULK AMENITY DISPENSER AT LAVATORIES
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
Revision Schedule
Number Description Date
TVTV
A-420B2
1
4
3
GFCI
SF-01
WC-01
WC-01
WC-01
WC-01
WC-01
CPT-10
CPT-01
RES-01
CT-01
9
A-510
Sim
7
A-510
Sim
1
A-510
Sim
FULL TILE
FULL TILE17' - 8 3/4"8' - 5 3/4"FULL TILEFULL TILE
6
A-510
Sim
PLAN ELEV
DUPLEX OUTLET
QUADPLEX OUTLET
GFCI OUTLET
CAT6, RJ45 INTERNET OUTLET
TELEPHONE OUTLET
WALL MOUNTED WIRELESS THERMOSTAT
POWER OUTLET WITH USB PORTS
CATV OUTLET
ELECTRICAL SWITCH
FLOOR OUTLET
POWER AND SIGNAL LEGEND:
POWER SUPPLY
CEILING FIXTURE LEGEND:
6" RECESSED CAN DOWNLIGHT
DECORATIVE FLUSH MOUNT LIGHT
PENDENT TYPE SPRINKLERS
SMOKE DETECTOR
EXHAUST FAN / GRILLE
LINEAR SURFACE MOUNTED CONTINUOUS LED SYSTEM W/ FIXED MOUNTING CLIPS & FROSTED LENS / 3 WATTS PER FOOT, MLV/FWD
ELECTRICAL OUTLET HEIGHTS (U.N.O)
TYPICAL OUTLET - 15" A.F.F
TYPICAL ACCESSIBLE WALL OUTLET - 18" A.F.F
BATHROOM VANITY OUTLET - 42" A.F.F
TYP. KITCHEN OUTLET - 42" A.F.F
ADA KITCHEN OUTLET - 46" A.F.F
ADA BATHROOM VANITY OUTLET - 44" A.F.F
ELECTRICAL SWITCH HEIGHTS (U.N.O)
SWITCH - 44" A.F.F
THERMOSTAT REMOTE - 48" A.F.F MAX TO TOP OF SWITCH
JUNCTION BOX
DOOR BELL HARDWIRED TO DOORBELL LIGHT - MOUNT @ 46" A.F.F TO CENTER OF BUTTON (FOR COMMUNICATIONS FEATURES ROOMS ONLY)
SD
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216UNIT PLAN - DOUBLEQUEEN STUDIO - ELEC,DATA & FLOOR FINISHPLAN
A-420A
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
0'1' 2'4'
SCALE: 1/2" = 1'-0"
1/2" = 1'-0"1DOUBLE QUEEN STUDIO UNIT ELECTRICAL & DATA PLAN
Units x10, x22, x24, x35-x36
1/2" = 1'-0"2DOUBLE QUEEN STUDIO UNIT FLOOR & WALL FINISH PLAN
Units x10, x22, x24, x35-x36
15
10
12
8
9
11
13
16
14
3
KEYNOTES - UNIT PLANS
1 ALIGN
2 GENERAL CONTRACTOR TO COORDINATE W/ FURNITUREFABRICATOR WHERE NECESSARY TO PROVIDE PROPERBLOCKING IN WALL FOR ITEM KEYNOTED
3 NO FINISHES UNDER THE SHOWER PAN / TUB
4 NO FINISHES UNDER MILLWORK CABINETRY
5 TV AND MOUNT NOT TO PROJECT MORE THAN 4" FROMWALL
6 MOTORIZED BLINDS. PROVIDE JUNCTION BOX BEHINDVALENCE FOR POWER CONNECTION AND PERMANENTLYINSTALLED SWITCH ON WALL TO CONTROL BLINDS.
7 SWITCH CONTROLLING UNDER CABINET LIGHTING ATKITCHEN TO BE GANGED WITH LIGHTING AT ENTRY
8 SWITCH CONTROLLING GARBAGE DISPOSAL-REFER TOHADG FOR ACCESSIBLE ROOM REQ'S.
9 DEDICATED CIRCUIT FOR GARBAGE DISPOSAL
10 MASTER SWITCH
11 DEDICATED CIRCUIT FOR INDUCTION COOKTOP
12 DEDICATED CIRCUIT FOR DISHWASHER
13 DEDICATED CIRCUIT FOR REFRIGERATOR
14 ELECTRIC VANITY MIRROR - HARDWIRE FIXTURE TO WALL-CONTRACTOR TO VERIFY JBOX TYPE TO ENSURE PROPERINSTALLATION AND BACKING FOR ITEM KEYNOTED
15 DOORBELL AND DOORBELL ON/OFF SWITCH(COMMUNICATION FEATURES ROOMS ONLY)SIGNAGE ASREQ'D.
16 PLACE TV OUTLETS AND CONNECTIONS ON WALL OUTSIDEAREA OF BRACKET AND CONCEALED FROM VIEW BY TV
17 DEDICATED CIRCUIT FOR WASHER/DRYER. DIRECT VENTTO EXTERIOR
FURNISHING SCHEDULE
GUESTROOM FURNISHINGS
GR-101 CHAIR - LOUNGE CHAIR IN STUIDOS
GR-103 CHAIR - KITCHEN STOOL
GR-105 SOFA - SLEEP BETWEEN ARMS
GR-201 SCONCE - NIGHTSTAND
GR-205 LAMP - FLOOR LAMP
GR-206 LAMP - DOUBLE QUEEN READING LAMP
GR-307 NIGHTSTAND - SMALL
GR-308 NIGHTSTAND - REGULAR
GR-312 TABLE - NESTING
GR-313 TABLE - ROUND SIDE TABLE
GR-314 TABLE - PRODUCTIVITY TABLE (STUDIO)
GR-318 DRESSER - HIGHBOY
GR-321 CLOSET - KING STUDIO SUITE
GR-326 VANITY - STUDIO AND 1-BEDROOM SUITES
GR-400 STATIC DRAPARY PANELS
GR-504 ART- SLEEPING/LIVING
GR-506 MIRROR - GUESTROOM FULL LENGTH
GR-508 MIRROR - GUESTROOM VANITY
GR-800 KITCHENETTE - 1-BEDROOM
GR-900 GUESTROOM REFRIGERATOR
GR-901 GUESTROOM DISHWASHER
GR-902 GUESTROOM COOKTOP - 2 BURNER
GR-904 GARBAGE DISPOSAL 1/3HP
GR-906GR-911 TELEVISION & TELEVISION MOUNT
GR-907 CLOCK/RADIO
GR-908 TELEPHONE - GUESTROOM
GR-QS BED - QUEEN (GR-302, 305, 601)
OWNER SPECIFIED - OWNER FURNISHED
OP-706 FIRE EXTINGUISHER CABINET
PLUMBING/MECHANICAL FIXTURES
PF-01 TOILET - GUESTROOM
PF-06 BATHTUB - 5' X 32" WITH SIDE LEDGE
PF-07 LAVATORY - UNDERMOUNT, 20" X 14"
PF-11 SHOWER HEAD - 2 IN 1
PF-13 SHOWER/TUB VALVE & CONTROL
PF-14 BATHTUB FILL FAUCET
PF-15 FAUCET - LAVATORY
PF-40 SINK - KITCHENETTE
PF-41 FAUCET - KITCHENETTE
TOILET ACCESSORIES
HD-01 DUAL TOILET PAPER HOLDER
HD-04.1 TOWEL BAR
HD-08 18" GRAB BAR
HD-16 BULK AMENITY DISPENSER ATSHOWERS/TUBS
HD-18.1 SOAP SHELF
HD-21 BULK AMENITY DISPENSER AT LAVATORIES
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
Revision Schedule
Number Description Date
TV
5' - 0"D-G01
PT-11PL-01WC-01WC-01
4' - 2"
GR-203
WD-01
WD-01
WC-01
4' - 0 3/4"
PT-03 PL-02
WC-01
GR-905
GR-901
GR-900
GR-902
D-G02
WD-01
WC-01
0' - 9"4' - 2"5' - 1"GR-906GR-911
P3.2
G-006
GR-205
SF-01
GR-412
PT-03
16
A-510
Sim
W-G
GR-400
GR-402
WC-01
D-G03
5' - 2"2' - 3"3' - 2"0' - 6"PLANELEV
DUPLEX OUTLET
QUADPLEX OUTLET
GFCI OUTLET
CAT6, RJ45 INTERNET OUTLET
TELEPHONE OUTLET
WALL MOUNTED WIRELESS THERMOSTAT
POWER OUTLET WITH USB PORTS
CATV OUTLET
ELECTRICAL SWITCH
FLOOR OUTLET
POWER AND SIGNAL LEGEND:
POWER SUPPLY
JUNCTION BOX
DOOR BELL HARDWIRED TO DOORBELL LIGHT - MOUNT @ 46" A.F.F TO CENTER OF BUTTON (FOR COMMUNICATIONS FEATURES ROOMS ONLY)
CEILING FIXTURE LEGEND:
6" RECESSED CAN DOWNLIGHT
DECORATIVE FLUSH MOUNT LIGHT
PENDENT TYPE SPRINKLERS
SMOKE DETECTOR
EXHAUST FAN / GRILLE
LINEAR SURFACE MOUNTED CONTINUOUS LED SYSTEM W/ FIXED MOUNTING CLIPS & FROSTED LENS / 3 WATTS PER FOOT, MLV/FWD
ELECTRICAL OUTLET HEIGHTS (U.N.O)
TYPICAL OUTLET - 15" A.F.F
TYPICAL ACCESSIBLE WALL OUTLET - 18" A.F.F
BATHROOM VANITY OUTLET - 42" A.F.F
TYP. KITCHEN OUTLET - 42" A.F.F
ADA KITCHEN OUTLET - 46" A.F.F
ADA BATHROOM VANITY OUTLET - 44" A.F.F
ELECTRICAL SWITCH HEIGHTS (U.N.O)
SWITCH - 44" A.F.F
THERMOSTAT REMOTE - 48" A.F.F MAX TO TOP OF SWITCH
SD
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216UNIT INT. ELEVATION -DOUBLE QUEEN STUDIO
A-420B
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
FFL
FFL
1/2" = 1'-0" Reference: 1 / A-420
1DOUBLE QUEEN STUDIO ELEVATION A
Units x10, x22, x24, x35-x36 1/2" = 1'-0" Reference: 1 / A-420
2DOUBLE QUEEN STUDIO ELEVATION B
Units x10, x22, x24, x35-x36
1/2" = 1'-0" Reference: 1 / A-420
3DOUBLE QUEEN STUDIO ELEVATION C
Units x10, x22, x24, x35-x36 1/2" = 1'-0" Reference: 1 / A-420
4DOUBLE QUEEN STUDIO ELEVATION D
Units x10, x22, x24, x35-x36
FURNISHING SCHEDULE
GUESTROOM FURNISHINGS
GR-101 CHAIR - LOUNGE CHAIR IN STUIDOS
GR-103 CHAIR - KITCHEN STOOL
GR-105 SOFA - SLEEP BETWEEN ARMS
GR-201 SCONCE - NIGHTSTAND
GR-203 PENDANT LIGHT - PRODUCTIVITY TABLE
GR-205 LAMP - FLOOR LAMP
GR-206 LAMP - DOUBLE QUEEN READING LAMP
GR-307 NIGHTSTAND - SMALL
GR-308 NIGHTSTAND - REGULAR
GR-312 TABLE - NESTING
GR-313 TABLE - ROUND SIDE TABLE
GR-314 TABLE - PRODUCTIVITY TABLE (STUDIO)
GR-318 DRESSER - HIGHBOY
GR-321 CLOSET - KING STUDIO SUITE
GR-326 VANITY - STUDIO AND 1-BEDROOM SUITES
GR-400 STATIC DRAPARY PANELS
GR-402 ROLLER SHADE - GUESTROOMS (MANUAL,SHEER/BLACK-OUT, 5' W)
GR-403 ROLLER SHADE - GUESTROOMS (MANUAL,SHEER/BLACK-OUT, 8' W)
GR-412 VALENCE FOR 8' WINDOW
GR-502 ART
GR-503 ART- ENTRY
GR-504 ART- SLEEPING/LIVING
GR-505 WALL HOOK
GR-506 MIRROR - GUESTROOM FULL LENGTH
FURNISHING SCHEDULE
GR-508 MIRROR - GUESTROOM VANITY
GR-800 KITCHENETTE - 1-BEDROOM
GR-900 GUESTROOM REFRIGERATOR
GR-901 GUESTROOM DISHWASHER
GR-902 GUESTROOM COOKTOP - 2 BURNER
GR-904 GARBAGE DISPOSAL 1/3HP
GR-905 MICROWAVE- WITH RECIRCULATING HOOD
GR-906GR-911 TELEVISION & TELEVISION MOUNT
GR-907 CLOCK/RADIO
GR-908 TELEPHONE - GUESTROOM
GR-KS BED - KING (GR-301, 303, 600)
GR-QS BED - QUEEN (GR-302, 305, 601)
OWNER SPECIFIED - OWNER FURNISHED
OP-706 FIRE EXTINGUISHER CABINET
PLUMBING/MECHANICAL FIXTURES
PF-01 TOILET - GUESTROOM
PF-03 SHOWER BASE - 60" X 36" WITH LINEARDRAIN
PF-06 BATHTUB - 5' X 32" WITH SIDE LEDGE
PF-07 LAVATORY - UNDERMOUNT, 20" X 14"
PF-11 SHOWER HEAD - 2 IN 1
PF-13 SHOWER/TUB VALVE & CONTROL
PF-14 BATHTUB FILL FAUCET
PF-15 FAUCET - LAVATORY
KEYNOTES - UNIT PLANS
1 ALIGN
2 GENERAL CONTRACTOR TO COORDINATE W/ FURNITUREFABRICATOR WHERE NECESSARY TO PROVIDE PROPERBLOCKING IN WALL FOR ITEM KEYNOTED
3 NO FINISHES UNDER THE SHOWER PAN / TUB
4 NO FINISHES UNDER MILLWORK CABINETRY
5 TV AND MOUNT NOT TO PROJECT MORE THAN 4" FROMWALL
6 MOTORIZED BLINDS. PROVIDE JUNCTION BOX BEHINDVALENCE FOR POWER CONNECTION AND PERMANENTLYINSTALLED SWITCH ON WALL TO CONTROL BLINDS.
7 SWITCH CONTROLLING UNDER CABINET LIGHTING ATKITCHEN TO BE GANGED WITH LIGHTING AT ENTRY
8 SWITCH CONTROLLING GARBAGE DISPOSAL-REFER TOHADG FOR ACCESSIBLE ROOM REQ'S.
9 DEDICATED CIRCUIT FOR GARBAGE DISPOSAL
10 MASTER SWITCH
11 DEDICATED CIRCUIT FOR INDUCTION COOKTOP
12 DEDICATED CIRCUIT FOR DISHWASHER
13 DEDICATED CIRCUIT FOR REFRIGERATOR
14 ELECTRIC VANITY MIRROR - HARDWIRE FIXTURE TO WALL-CONTRACTOR TO VERIFY JBOX TYPE TO ENSURE PROPERINSTALLATION AND BACKING FOR ITEM KEYNOTED
15 DOORBELL AND DOORBELL ON/OFF SWITCH(COMMUNICATION FEATURES ROOMS ONLY)SIGNAGE ASREQ'D.
16 PLACE TV OUTLETS AND CONNECTIONS ON WALL OUTSIDEAREA OF BRACKET AND CONCEALED FROM VIEW BY TV
17 DEDICATED CIRCUIT FOR WASHER/DRYER. DIRECT VENTTO EXTERIOR
FURNISHING SCHEDULE
PF-40 SINK - KITCHENETTE
PF-41 FAUCET - KITCHENETTE
TOILET ACCESSORIES
HD-01 DUAL TOILET PAPER HOLDER
HD-04 WALL-MOUNTED ROBE HOOK
HD-04.1 TOWEL BAR
HD-05 CURVED CURTAIN ROD AND SHOWERCURTAIN
HD-05.2 SLIDING SHOWER DOOR
HD-08 18" GRAB BAR
HD-16 BULK AMENITY DISPENSER ATSHOWERS/TUBS
HD-18 FOOT LEDGE FOR SHOWER
HD-18.1 SOAP SHELF
HD-21 BULK AMENITY DISPENSER AT LAVATORIES
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
Revision Schedule
Number Description Date
MAATVSD
TV
A-421B2
1
3
4
A-424
2
D-G01A
W-GXE1/2
D-G03A12' - 5 3/4"18' - 0 1/4"9' - 9 1/4"9' - 1 1/4"4' - 9"11' - 2 1/2"7' - 8 1/2"
7' - 1 1/4"
0' - 6 1/2"11' - 2 1/2"
GR-103
GR-103
GR-105GR-312
GR-205
GR-101GR-313
GR-QM
GR-QM
GR-206
GR-201
GR-201
GR-308
GR-206
GR-907
GR-908GR-906GR-911
XE1/2
D-G02A
P3.1
GR-503
GR-322
GR-507
GR-400 GR-400
CL-B27' - 6"
CL-B8' - 0"
4' - 2"4' - 2"5' - 2"7' - 7"5' - 2"1
1
1
1
2' - 8"2' - 11 1/4"3' - 8"2' - 6"3' - 6 1/2"4' - 0"1
1
1
PLAN ELEV
DUPLEX OUTLET
QUADPLEX OUTLET
GFCI OUTLET
CAT6, RJ45 INTERNET OUTLET
TELEPHONE OUTLET
WALL MOUNTED WIRELESS THERMOSTAT
POWER OUTLET WITH USB PORTS
CATV OUTLET
ELECTRICAL SWITCH
FLOOR OUTLET
POWER AND SIGNAL LEGEND:
POWER SUPPLY
CEILING FIXTURE LEGEND:
6" RECESSED CAN DOWNLIGHT
DECORATIVE FLUSH MOUNT LIGHT
PENDENT TYPE SPRINKLERS
SMOKE DETECTOR
EXHAUST FAN / GRILLE
LINEAR SURFACE MOUNTED CONTINUOUS LED SYSTEM W/ FIXED MOUNTING CLIPS & FROSTED LENS / 3 WATTS PER FOOT, MLV/FWD
ELECTRICAL OUTLET HEIGHTS (U.N.O)
TYPICAL OUTLET - 15" A.F.F
TYPICAL ACCESSIBLE WALL OUTLET - 18" A.F.F
BATHROOM VANITY OUTLET - 42" A.F.F
TYP. KITCHEN OUTLET - 42" A.F.F
ADA KITCHEN OUTLET - 46" A.F.F
ADA BATHROOM VANITY OUTLET - 44" A.F.F
ELECTRICAL SWITCH HEIGHTS (U.N.O)
SWITCH - 44" A.F.F
THERMOSTAT REMOTE - 48" A.F.F MAX TO TOP OF SWITCH
JUNCTION BOX
DOOR BELL HARDWIRED TO DOORBELL LIGHT - MOUNT @ 46" A.F.F TO CENTER OF BUTTON (FOR COMMUNICATIONS FEATURES ROOMS ONLY)
SD
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216UNIT PLAN - DOUBLEQUEEN STUDIO ADAMOBILITY
A-421
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
0'1' 2'4'
SCALE: 1/2" = 1'-0"
1/2" = 1'-0" Reference: 1 / A-105
1DOUBLE QUEEN STUDIO ADA MOBILITY CONSTRUCTION PLAN
Unit 512
1/2" = 1'-0" Reference: 1 / x-115
2DOUBLE QUEEN STUDIO ADA MOBILITY RCP
Unit 512
2
2
5
2
2
KEYNOTES - UNIT PLANS
1 ALIGN
2 GENERAL CONTRACTOR TO COORDINATE W/ FURNITUREFABRICATOR WHERE NECESSARY TO PROVIDE PROPERBLOCKING IN WALL FOR ITEM KEYNOTED
3 NO FINISHES UNDER THE SHOWER PAN / TUB
4 NO FINISHES UNDER MILLWORK CABINETRY
5 TV AND MOUNT NOT TO PROJECT MORE THAN 4" FROMWALL
6 MOTORIZED BLINDS. PROVIDE JUNCTION BOX BEHINDVALENCE FOR POWER CONNECTION AND PERMANENTLYINSTALLED SWITCH ON WALL TO CONTROL BLINDS.
7 SWITCH CONTROLLING UNDER CABINET LIGHTING ATKITCHEN TO BE GANGED WITH LIGHTING AT ENTRY
8 SWITCH CONTROLLING GARBAGE DISPOSAL-REFER TOHADG FOR ACCESSIBLE ROOM REQ'S.
9 DEDICATED CIRCUIT FOR GARBAGE DISPOSAL
10 MASTER SWITCH
11 DEDICATED CIRCUIT FOR INDUCTION COOKTOP
12 DEDICATED CIRCUIT FOR DISHWASHER
13 DEDICATED CIRCUIT FOR REFRIGERATOR
14 ELECTRIC VANITY MIRROR - HARDWIRE FIXTURE TO WALL-CONTRACTOR TO VERIFY JBOX TYPE TO ENSURE PROPERINSTALLATION AND BACKING FOR ITEM KEYNOTED
15 DOORBELL AND DOORBELL ON/OFF SWITCH(COMMUNICATION FEATURES ROOMS ONLY)SIGNAGE ASREQ'D.
16 PLACE TV OUTLETS AND CONNECTIONS ON WALL OUTSIDEAREA OF BRACKET AND CONCEALED FROM VIEW BY TV
17 DEDICATED CIRCUIT FOR WASHER/DRYER. DIRECT VENTTO EXTERIOR
FURNISHING SCHEDULE
GUESTROOM FURNISHINGS
GR-101 CHAIR - LOUNGE CHAIR IN STUIDOS
GR-103 CHAIR - KITCHEN STOOL
GR-105 SOFA - SLEEP BETWEEN ARMS
GR-201 SCONCE - NIGHTSTAND
GR-203 PENDANT LIGHT - PRODUCTIVITY TABLE
GR-205 LAMP - FLOOR LAMP
GR-206 LAMP - DOUBLE QUEEN READING LAMP
GR-308 NIGHTSTAND - REGULAR
GR-312 TABLE - NESTING
GR-313 TABLE - ROUND SIDE TABLE
GR-314 TABLE - PRODUCTIVITY TABLE (STUDIO)
GR-322 CLOSET - ACCESSIBLE KING STUDIO SUITE
GR-327 VANITY - ACCESSIBLE SUITES
GR-328 BATH CADDY - ACCESSIBLE SUITES
GR-400 STATIC DRAPARY PANELS
GR-403 ROLLER SHADE - GUESTROOMS (MANUAL,SHEER/BLACK-OUT, 8' W)
GR-412 VALENCE FOR 8' WINDOW
GR-503 ART- ENTRY
GR-506 MIRROR - GUESTROOM FULL LENGTH
GR-507 MIRROR - ADA VANITY
GR-800 KITCHENETTE - 1-BEDROOM
GR-900 GUESTROOM REFRIGERATOR
GR-901 GUESTROOM DISHWASHER
GR-902 GUESTROOM COOKTOP - 2 BURNER
GR-906GR-911 TELEVISION & TELEVISION MOUNT
GR-907 CLOCK/RADIO
GR-908 TELEPHONE - GUESTROOM
GR-912 RECIRCULATING HOOD
GR-QM BED - QUEEN MOBILITY (GR-302, 306, 601,603)
PLUMBING/MECHANICAL FIXTURES
PF-01 TOILET - GUESTROOM
PF-06 BATHTUB - 5' X 32" WITH SIDE LEDGE
PF-07 LAVATORY - UNDERMOUNT, 20" X 14"
PF-10 SHOWER HEAD - HIGH
PF-12 SHOWER HEAD - HAND HELD ON SLIDE BAR
PF-13 SHOWER/TUB VALVE & CONTROL
PF-14 BATHTUB FILL FAUCET
PF-15 FAUCET - LAVATORY
PF-41 FAUCET - KITCHENETTE
PF-42 SINK - ADA KITCHENETTE
TOILET ACCESSORIES
HD-02 DUAL TOILET PAPER HOLDER- ADA
HD-04 WALL-MOUNTED ROBE HOOK
HD-04.1 TOWEL BAR
HD-05 CURVED CURTAIN ROD AND SHOWERCURTAIN
HD-08 18" GRAB BAR
HD-09 24" GRAB BAR
HD-10 42" GRAB BAR AT ADA BATHTUB
HD-11 36" GRAB BAR
HD-11.1 42" GRAB BAR
HD-14.1 ROLL-IN SHOWER SEAT
HD-16 BULK AMENITY DISPENSER ATSHOWERS/TUBS
HD-18.1 SOAP SHELF
HD-20 12" GRAB BAR
HD-21 BULK AMENITY DISPENSER AT LAVATORIES
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
Revision Schedule
Number Description Date
TVTV
A-421B2
1
3
4
RES-01
CPT-01
CT-01
SF-01
WC-01 WC-01
WC-01
WC-01
FULL TILEFULL TILE18' - 0 1/4"8' - 8"FULL TILEFULL TILE
WC-01
CPT-10
1
A-510
Sim
9
A-510
Sim
6
A-510
Sim
7
A-510
Sim
PLAN ELEV
DUPLEX OUTLET
QUADPLEX OUTLET
GFCI OUTLET
CAT6, RJ45 INTERNET OUTLET
TELEPHONE OUTLET
WALL MOUNTED WIRELESS THERMOSTAT
POWER OUTLET WITH USB PORTS
CATV OUTLET
ELECTRICAL SWITCH
FLOOR OUTLET
POWER AND SIGNAL LEGEND:
POWER SUPPLY
CEILING FIXTURE LEGEND:
6" RECESSED CAN DOWNLIGHT
DECORATIVE FLUSH MOUNT LIGHT
PENDENT TYPE SPRINKLERS
SMOKE DETECTOR
EXHAUST FAN / GRILLE
LINEAR SURFACE MOUNTED CONTINUOUS LED SYSTEM W/ FIXED MOUNTING CLIPS & FROSTED LENS / 3 WATTS PER FOOT, MLV/FWD
ELECTRICAL OUTLET HEIGHTS (U.N.O)
TYPICAL OUTLET - 15" A.F.F
TYPICAL ACCESSIBLE WALL OUTLET - 18" A.F.F
BATHROOM VANITY OUTLET - 42" A.F.F
TYP. KITCHEN OUTLET - 42" A.F.F
ADA KITCHEN OUTLET - 46" A.F.F
ADA BATHROOM VANITY OUTLET - 44" A.F.F
ELECTRICAL SWITCH HEIGHTS (U.N.O)
SWITCH - 44" A.F.F
THERMOSTAT REMOTE - 48" A.F.F MAX TO TOP OF SWITCH
JUNCTION BOX
DOOR BELL HARDWIRED TO DOORBELL LIGHT - MOUNT @ 46" A.F.F TO CENTER OF BUTTON (FOR COMMUNICATIONS FEATURES ROOMS ONLY)
SD
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216UNIT PLAN - DOUBLEQUEEN STUDIO ADA-ELEC, DATA & FLOORFINISH PLAN
A-421A
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
1/2" = 1'-0"1DOUBLE QUEEN STUDIO ADA ELECTRICAL & DATA PLAN
Unit 512
1/2" = 1'-0"2DOUBLE QUEEN STUDIO ADA FLOOR & WALL FINISH PLAN
Unit 512
15
10
12
8
9
11
13
16
14
3
0'1' 2'4'
SCALE: 1/2" = 1'-0"
KEYNOTES - UNIT PLANS
1 ALIGN
2 GENERAL CONTRACTOR TO COORDINATE W/ FURNITUREFABRICATOR WHERE NECESSARY TO PROVIDE PROPERBLOCKING IN WALL FOR ITEM KEYNOTED
3 NO FINISHES UNDER THE SHOWER PAN / TUB
4 NO FINISHES UNDER MILLWORK CABINETRY
5 TV AND MOUNT NOT TO PROJECT MORE THAN 4" FROMWALL
6 MOTORIZED BLINDS. PROVIDE JUNCTION BOX BEHINDVALENCE FOR POWER CONNECTION AND PERMANENTLYINSTALLED SWITCH ON WALL TO CONTROL BLINDS.
7 SWITCH CONTROLLING UNDER CABINET LIGHTING ATKITCHEN TO BE GANGED WITH LIGHTING AT ENTRY
8 SWITCH CONTROLLING GARBAGE DISPOSAL-REFER TOHADG FOR ACCESSIBLE ROOM REQ'S.
9 DEDICATED CIRCUIT FOR GARBAGE DISPOSAL
10 MASTER SWITCH
11 DEDICATED CIRCUIT FOR INDUCTION COOKTOP
12 DEDICATED CIRCUIT FOR DISHWASHER
13 DEDICATED CIRCUIT FOR REFRIGERATOR
14 ELECTRIC VANITY MIRROR - HARDWIRE FIXTURE TO WALL-CONTRACTOR TO VERIFY JBOX TYPE TO ENSURE PROPERINSTALLATION AND BACKING FOR ITEM KEYNOTED
15 DOORBELL AND DOORBELL ON/OFF SWITCH(COMMUNICATION FEATURES ROOMS ONLY)SIGNAGE ASREQ'D.
16 PLACE TV OUTLETS AND CONNECTIONS ON WALL OUTSIDEAREA OF BRACKET AND CONCEALED FROM VIEW BY TV
17 DEDICATED CIRCUIT FOR WASHER/DRYER. DIRECT VENTTO EXTERIOR
FURNISHING SCHEDULE
GUESTROOM FURNISHINGS
GR-101 CHAIR - LOUNGE CHAIR IN STUIDOS
GR-103 CHAIR - KITCHEN STOOL
GR-105 SOFA - SLEEP BETWEEN ARMS
GR-201 SCONCE - NIGHTSTAND
GR-205 LAMP - FLOOR LAMP
GR-206 LAMP - DOUBLE QUEEN READING LAMP
GR-308 NIGHTSTAND - REGULAR
GR-312 TABLE - NESTING
GR-313 TABLE - ROUND SIDE TABLE
GR-314 TABLE - PRODUCTIVITY TABLE (STUDIO)
GR-322 CLOSET - ACCESSIBLE KING STUDIO SUITE
GR-327 VANITY - ACCESSIBLE SUITES
GR-328 BATH CADDY - ACCESSIBLE SUITES
GR-400 STATIC DRAPARY PANELS
GR-503 ART- ENTRY
GR-506 MIRROR - GUESTROOM FULL LENGTH
GR-507 MIRROR - ADA VANITY
GR-800 KITCHENETTE - 1-BEDROOM
GR-900 GUESTROOM REFRIGERATOR
GR-901 GUESTROOM DISHWASHER
GR-902 GUESTROOM COOKTOP - 2 BURNER
GR-906GR-911 TELEVISION & TELEVISION MOUNT
GR-907 CLOCK/RADIO
GR-908 TELEPHONE - GUESTROOM
GR-QM BED - QUEEN MOBILITY (GR-302, 306, 601,603)
PLUMBING/MECHANICAL FIXTURES
PF-01 TOILET - GUESTROOM
PF-06 BATHTUB - 5' X 32" WITH SIDE LEDGE
PF-07 LAVATORY - UNDERMOUNT, 20" X 14"
PF-12 SHOWER HEAD - HAND HELD ON SLIDE BAR
PF-13 SHOWER/TUB VALVE & CONTROL
PF-14 BATHTUB FILL FAUCET
PF-15 FAUCET - LAVATORY
PF-41 FAUCET - KITCHENETTE
PF-42 SINK - ADA KITCHENETTE
TOILET ACCESSORIES
HD-02 DUAL TOILET PAPER HOLDER- ADA
HD-04 WALL-MOUNTED ROBE HOOK
HD-04.1 TOWEL BAR
HD-08 18" GRAB BAR
HD-09 24" GRAB BAR
HD-10 42" GRAB BAR AT ADA BATHTUB
HD-11 36" GRAB BAR
HD-11.1 42" GRAB BAR
HD-14.1 ROLL-IN SHOWER SEAT
HD-16 BULK AMENITY DISPENSER ATSHOWERS/TUBS
HD-18.1 SOAP SHELF
HD-20 12" GRAB BAR
HD-21 BULK AMENITY DISPENSER AT LAVATORIES
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
Revision Schedule
Number Description Date
TV
WC-01
RB-015' - 0"4' - 3 1/4"
WD-01
WC-01
4' - 2"WD-01 SS-01
RB-01
5' - 5 1/4"
WC-01 5' - 1"EQ EQ
GR-403
6
D-G02A
GR-900
GR-901
PL-02 PT-03
SF-01
W-G
RB-01
16
A-510
Sim
GR-403GR-403
4' - 11"EQ EQ
RB-01RB-01
WC-01WC-01
RB-01
PLANELEV
DUPLEX OUTLET
QUADPLEX OUTLET
GFCI OUTLET
CAT6, RJ45 INTERNET OUTLET
TELEPHONE OUTLET
WALL MOUNTED WIRELESS THERMOSTAT
POWER OUTLET WITH USB PORTS
CATV OUTLET
ELECTRICAL SWITCH
FLOOR OUTLET
POWER AND SIGNAL LEGEND:
POWER SUPPLY
JUNCTION BOX
DOOR BELL HARDWIRED TO DOORBELL LIGHT - MOUNT @ 46" A.F.F TO CENTER OF BUTTON (FOR COMMUNICATIONS FEATURES ROOMS ONLY)
CEILING FIXTURE LEGEND:
6" RECESSED CAN DOWNLIGHT
DECORATIVE FLUSH MOUNT LIGHT
PENDENT TYPE SPRINKLERS
SMOKE DETECTOR
EXHAUST FAN / GRILLE
LINEAR SURFACE MOUNTED CONTINUOUS LED SYSTEM W/ FIXED MOUNTING CLIPS & FROSTED LENS / 3 WATTS PER FOOT, MLV/FWD
ELECTRICAL OUTLET HEIGHTS (U.N.O)
TYPICAL OUTLET - 15" A.F.F
TYPICAL ACCESSIBLE WALL OUTLET - 18" A.F.F
BATHROOM VANITY OUTLET - 42" A.F.F
TYP. KITCHEN OUTLET - 42" A.F.F
ADA KITCHEN OUTLET - 46" A.F.F
ADA BATHROOM VANITY OUTLET - 44" A.F.F
ELECTRICAL SWITCH HEIGHTS (U.N.O)
SWITCH - 44" A.F.F
THERMOSTAT REMOTE - 48" A.F.F MAX TO TOP OF SWITCH
SD
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216UNIT INT. ELEVATION -DOUBLE QUEEN STUDIOADA MOBILITY
A-421B
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
FFL
FFL
1/2" = 1'-0" Reference: 1 / A-421
1DOUBLE QUEEN STUDIO ADA ELEVATION A
Unit 512
1/2" = 1'-0" Reference: 1 / A-421
2DOUBLE QUEEN STUDIO ADA ELEVATION B
Unit 512
1/2" = 1'-0" Reference: 1 / A-421
3DOUBLE QUEEN STUDIO ADA ELEVATION C
Unit 512
1/2" = 1'-0" Reference: 1 / A-421
4DOUBLE QUEEN STUDIO ADA ELEVATION D
Unit 512
FURNISHING SCHEDULE
GUESTROOM FURNISHINGS
GR-101 CHAIR - LOUNGE CHAIR IN STUIDOS
GR-105 SOFA - SLEEP BETWEEN ARMS
GR-201 SCONCE - NIGHTSTAND
GR-203 PENDANT LIGHT - PRODUCTIVITY TABLE
GR-205 LAMP - FLOOR LAMP
GR-206 LAMP - DOUBLE QUEEN READING LAMP
GR-307 NIGHTSTAND - SMALL
GR-308 NIGHTSTAND - REGULAR
GR-312 TABLE - NESTING
GR-313 TABLE - ROUND SIDE TABLE
GR-314 TABLE - PRODUCTIVITY TABLE (STUDIO)
GR-322 CLOSET - ACCESSIBLE KING STUDIO SUITE
GR-326 VANITY - STUDIO AND 1-BEDROOM SUITES
GR-327 VANITY - ACCESSIBLE SUITES
GR-328 BATH CADDY - ACCESSIBLE SUITES
GR-400 STATIC DRAPARY PANELS
GR-403 ROLLER SHADE - GUESTROOMS (MANUAL,SHEER/BLACK-OUT, 8' W)
GR-412 VALENCE FOR 8' WINDOW
GR-503 ART- ENTRY
GR-506 MIRROR - GUESTROOM FULL LENGTH
GR-507 MIRROR - ADA VANITY
GR-800 KITCHENETTE - 1-BEDROOM
GR-900 GUESTROOM REFRIGERATOR
FURNISHING SCHEDULE
GR-901 GUESTROOM DISHWASHER
GR-902 GUESTROOM COOKTOP - 2 BURNER
GR-904 GARBAGE DISPOSAL 1/3HP
GR-905 MICROWAVE- WITH RECIRCULATING HOOD
GR-906GR-911 TELEVISION & TELEVISION MOUNT
GR-907 CLOCK/RADIO
GR-908 TELEPHONE - GUESTROOM
GR-912 RECIRCULATING HOOD
GR-QM BED - QUEEN MOBILITY (GR-302, 306, 601, 603)
GR-QS BED - QUEEN (GR-302, 305, 601)
OWNER SPECIFIED - OWNER FURNISHED
OP-706 FIRE EXTINGUISHER CABINET
PLUMBING/MECHANICAL FIXTURES
PF-01 TOILET - GUESTROOM
PF-03 SHOWER BASE - 60" X 36" WITH LINEAR DRAIN
PF-06 BATHTUB - 5' X 32" WITH SIDE LEDGE
PF-07 LAVATORY - UNDERMOUNT, 20" X 14"
PF-10 SHOWER HEAD - HIGH
PF-11 SHOWER HEAD - 2 IN 1
PF-12 SHOWER HEAD - HAND HELD ON SLIDE BAR
PF-13 SHOWER/TUB VALVE & CONTROL
FURNISHING SCHEDULE
PF-14 BATHTUB FILL FAUCET
PF-15 FAUCET - LAVATORY
PF-40 SINK - KITCHENETTE
PF-41 FAUCET - KITCHENETTE
PF-42 SINK - ADA KITCHENETTE
TOILET ACCESSORIES
HD-02 DUAL TOILET PAPER HOLDER- ADA
HD-04 WALL-MOUNTED ROBE HOOK
HD-04.1 TOWEL BAR
HD-05 CURVED CURTAIN ROD AND SHOWER CURTAIN
HD-05.2 SLIDING SHOWER DOOR
HD-08 18" GRAB BAR
HD-09 24" GRAB BAR
HD-10 42" GRAB BAR AT ADA BATHTUB
HD-11 36" GRAB BAR
HD-11.1 42" GRAB BAR
HD-14.1 ROLL-IN SHOWER SEAT
HD-16 BULK AMENITY DISPENSER AT SHOWERS/TUBS
HD-18.1 SOAP SHELF
HD-20 12" GRAB BAR
HD-21 BULK AMENITY DISPENSER AT LAVATORIES
KEYNOTES - UNIT PLANS
1 ALIGN
2 GENERAL CONTRACTOR TO COORDINATE W/ FURNITUREFABRICATOR WHERE NECESSARY TO PROVIDE PROPERBLOCKING IN WALL FOR ITEM KEYNOTED
3 NO FINISHES UNDER THE SHOWER PAN / TUB
4 NO FINISHES UNDER MILLWORK CABINETRY
5 TV AND MOUNT NOT TO PROJECT MORE THAN 4" FROMWALL
6 MOTORIZED BLINDS. PROVIDE JUNCTION BOX BEHINDVALENCE FOR POWER CONNECTION AND PERMANENTLYINSTALLED SWITCH ON WALL TO CONTROL BLINDS.
7 SWITCH CONTROLLING UNDER CABINET LIGHTING ATKITCHEN TO BE GANGED WITH LIGHTING AT ENTRY
8 SWITCH CONTROLLING GARBAGE DISPOSAL-REFER TOHADG FOR ACCESSIBLE ROOM REQ'S.
9 DEDICATED CIRCUIT FOR GARBAGE DISPOSAL
10 MASTER SWITCH
11 DEDICATED CIRCUIT FOR INDUCTION COOKTOP
12 DEDICATED CIRCUIT FOR DISHWASHER
13 DEDICATED CIRCUIT FOR REFRIGERATOR
14 ELECTRIC VANITY MIRROR - HARDWIRE FIXTURE TO WALL-CONTRACTOR TO VERIFY JBOX TYPE TO ENSURE PROPERINSTALLATION AND BACKING FOR ITEM KEYNOTED
15 DOORBELL AND DOORBELL ON/OFF SWITCH(COMMUNICATION FEATURES ROOMS ONLY)SIGNAGE ASREQ'D.
16 PLACE TV OUTLETS AND CONNECTIONS ON WALL OUTSIDEAREA OF BRACKET AND CONCEALED FROM VIEW BY TV
17 DEDICATED CIRCUIT FOR WASHER/DRYER. DIRECT VENTTO EXTERIOR
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
Revision Schedule
Number Description Date
MMAATVSD
TV
CL-B27' - 6"
CL-B27' - 6"
CL-B8' - 0"
GR-400 GR-4001' - 5"1' - 5"3' - 8 1/4"5' - 7 1/4"2' - 4"5' - 10 1/2"4' - 0"OF TABLE
1
1
1
1
1 1
1
1
A-422B2
1
4
3
P3.1
D-G03
D-G01
D-G02
W-GXE3
D-G03
18' - 9 1/4"9' - 9 1/4"9' - 1 1/4"
1' - 10"2' - 2 3/4"2' - 1"
6' - 6 1/2"12' - 3 1/2"
11' - 9"0' - 6 1/2"
7' - 1 1/4"
GR-900
GR-902
GR-508
GR-901
GR-308
GR-201
GR-908GR-906GR-911
GR-101
GR-205
GR-313
GR-312
GR-105GR-QS
GR-QS
GR-206
GR-206
GR-326
GR-907
GR-321
GR-506
GR-503
PLAN ELEV
DUPLEX OUTLET
QUADPLEX OUTLET
GFCI OUTLET
CAT6, RJ45 INTERNET OUTLET
TELEPHONE OUTLET
WALL MOUNTED WIRELESS THERMOSTAT
POWER OUTLET WITH USB PORTS
CATV OUTLET
ELECTRICAL SWITCH
FLOOR OUTLET
POWER AND SIGNAL LEGEND:
POWER SUPPLY
CEILING FIXTURE LEGEND:
6" RECESSED CAN DOWNLIGHT
DECORATIVE FLUSH MOUNT LIGHT
PENDENT TYPE SPRINKLERS
SMOKE DETECTOR
EXHAUST FAN / GRILLE
LINEAR SURFACE MOUNTED CONTINUOUS LED SYSTEM W/ FIXED MOUNTING CLIPS & FROSTED LENS / 3 WATTS PER FOOT, MLV/FWD
ELECTRICAL OUTLET HEIGHTS (U.N.O)
TYPICAL OUTLET - 15" A.F.F
TYPICAL ACCESSIBLE WALL OUTLET - 18" A.F.F
BATHROOM VANITY OUTLET - 42" A.F.F
TYP. KITCHEN OUTLET - 42" A.F.F
ADA KITCHEN OUTLET - 46" A.F.F
ADA BATHROOM VANITY OUTLET - 44" A.F.F
ELECTRICAL SWITCH HEIGHTS (U.N.O)
SWITCH - 44" A.F.F
THERMOSTAT REMOTE - 48" A.F.F MAX TO TOP OF SWITCH
JUNCTION BOX
DOOR BELL HARDWIRED TO DOORBELL LIGHT - MOUNT @ 46" A.F.F TO CENTER OF BUTTON (FOR COMMUNICATIONS FEATURES ROOMS ONLY)
SD
1/2" = 1'-0" Reference: 1 / A-102
1
DOUBLE QUEEN STUDIO ENLARGED UNIT CONSTRUCTIONPLAN
Units 212, 312, 412
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216UNIT PLAN - DOUBLEQUEEN STUDIOENLARGED
A-422
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
1/2" = 1'-0"2DOUBLE QUEEN STUDIO ENLARGED UNIT RCP
Units 212, 312, 412
0'1' 2'4'
SCALE: 1/2" = 1'-0"
2
5
22
2
2
KEYNOTES - UNIT PLANS
1 ALIGN
2 GENERAL CONTRACTOR TO COORDINATE W/ FURNITUREFABRICATOR WHERE NECESSARY TO PROVIDE PROPERBLOCKING IN WALL FOR ITEM KEYNOTED
3 NO FINISHES UNDER THE SHOWER PAN / TUB
4 NO FINISHES UNDER MILLWORK CABINETRY
5 TV AND MOUNT NOT TO PROJECT MORE THAN 4" FROMWALL
6 MOTORIZED BLINDS. PROVIDE JUNCTION BOX BEHINDVALENCE FOR POWER CONNECTION AND PERMANENTLYINSTALLED SWITCH ON WALL TO CONTROL BLINDS.
7 SWITCH CONTROLLING UNDER CABINET LIGHTING ATKITCHEN TO BE GANGED WITH LIGHTING AT ENTRY
8 SWITCH CONTROLLING GARBAGE DISPOSAL-REFER TOHADG FOR ACCESSIBLE ROOM REQ'S.
9 DEDICATED CIRCUIT FOR GARBAGE DISPOSAL
10 MASTER SWITCH
11 DEDICATED CIRCUIT FOR INDUCTION COOKTOP
12 DEDICATED CIRCUIT FOR DISHWASHER
13 DEDICATED CIRCUIT FOR REFRIGERATOR
14 ELECTRIC VANITY MIRROR - HARDWIRE FIXTURE TO WALL-CONTRACTOR TO VERIFY JBOX TYPE TO ENSURE PROPERINSTALLATION AND BACKING FOR ITEM KEYNOTED
15 DOORBELL AND DOORBELL ON/OFF SWITCH(COMMUNICATION FEATURES ROOMS ONLY)SIGNAGE ASREQ'D.
16 PLACE TV OUTLETS AND CONNECTIONS ON WALL OUTSIDEAREA OF BRACKET AND CONCEALED FROM VIEW BY TV
17 DEDICATED CIRCUIT FOR WASHER/DRYER. DIRECT VENTTO EXTERIOR
FURNISHING SCHEDULE
GUESTROOM FURNISHINGS
GR-101 CHAIR - LOUNGE CHAIR IN STUIDOS
GR-103 CHAIR - KITCHEN STOOL
GR-105 SOFA - SLEEP BETWEEN ARMS
GR-201 SCONCE - NIGHTSTAND
GR-203 PENDANT LIGHT - PRODUCTIVITY TABLE
GR-205 LAMP - FLOOR LAMP
GR-206 LAMP - DOUBLE QUEEN READING LAMP
GR-308 NIGHTSTAND - REGULAR
GR-312 TABLE - NESTING
GR-313 TABLE - ROUND SIDE TABLE
GR-314 TABLE - PRODUCTIVITY TABLE (STUDIO)
GR-318 DRESSER - HIGHBOY
GR-321 CLOSET - KING STUDIO SUITE
GR-326 VANITY - STUDIO AND 1-BEDROOM SUITES
GR-400 STATIC DRAPARY PANELS
GR-403 ROLLER SHADE - GUESTROOMS (MANUAL,SHEER/BLACK-OUT, 8' W)
GR-412 VALENCE FOR 8' WINDOW
GR-503 ART- ENTRY
GR-505 WALL HOOK
GR-506 MIRROR - GUESTROOM FULL LENGTH
GR-508 MIRROR - GUESTROOM VANITY
GR-800 KITCHENETTE - 1-BEDROOM
GR-900 GUESTROOM REFRIGERATOR
GR-901 GUESTROOM DISHWASHER
GR-902 GUESTROOM COOKTOP - 2 BURNER
GR-904 GARBAGE DISPOSAL 1/3HP
GR-905 MICROWAVE- WITH RECIRCULATING HOOD
GR-906GR-911 TELEVISION & TELEVISION MOUNT
GR-907 CLOCK/RADIO
GR-908 TELEPHONE - GUESTROOM
GR-QS BED - QUEEN (GR-302, 305, 601)
PLUMBING/MECHANICAL FIXTURES
PF-01 TOILET - GUESTROOM
PF-03 SHOWER BASE - 60" X 36" WITH LINEARDRAIN
PF-07 LAVATORY - UNDERMOUNT, 20" X 14"
PF-11 SHOWER HEAD - 2 IN 1
PF-13 SHOWER/TUB VALVE & CONTROL
PF-15 FAUCET - LAVATORY
PF-40 SINK - KITCHENETTE
PF-41 FAUCET - KITCHENETTE
TOILET ACCESSORIES
HD-01 DUAL TOILET PAPER HOLDER
HD-04 WALL-MOUNTED ROBE HOOK
HD-04.1 TOWEL BAR
HD-05.2 SLIDING SHOWER DOOR
HD-08 18" GRAB BAR
HD-16 BULK AMENITY DISPENSER ATSHOWERS/TUBS
HD-18 FOOT LEDGE FOR SHOWER
HD-18.1 SOAP SHELF
HD-21 BULK AMENITY DISPENSER AT LAVATORIES
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
Revision Schedule
Number Description Date
TVTV
A-422B2
1
4
3
A-454
WC-01
WC-01
WC-01
WC-01
WC-01
SF-01
FULL TILE
FULL TILE18' - 9 1/4"8' - 7"FULL TILEFULL TILE
RES-01
CPT-01
CT-01
CPT-10
9
A-510
Sim
1
A-510
Sim
6
A-510
Sim
7
A-510
Sim
PLAN ELEV
DUPLEX OUTLET
QUADPLEX OUTLET
GFCI OUTLET
CAT6, RJ45 INTERNET OUTLET
TELEPHONE OUTLET
WALL MOUNTED WIRELESS THERMOSTAT
POWER OUTLET WITH USB PORTS
CATV OUTLET
ELECTRICAL SWITCH
FLOOR OUTLET
POWER AND SIGNAL LEGEND:
POWER SUPPLY
CEILING FIXTURE LEGEND:
6" RECESSED CAN DOWNLIGHT
DECORATIVE FLUSH MOUNT LIGHT
PENDENT TYPE SPRINKLERS
SMOKE DETECTOR
EXHAUST FAN / GRILLE
LINEAR SURFACE MOUNTED CONTINUOUS LED SYSTEM W/ FIXED MOUNTING CLIPS & FROSTED LENS / 3 WATTS PER FOOT, MLV/FWD
ELECTRICAL OUTLET HEIGHTS (U.N.O)
TYPICAL OUTLET - 15" A.F.F
TYPICAL ACCESSIBLE WALL OUTLET - 18" A.F.F
BATHROOM VANITY OUTLET - 42" A.F.F
TYP. KITCHEN OUTLET - 42" A.F.F
ADA KITCHEN OUTLET - 46" A.F.F
ADA BATHROOM VANITY OUTLET - 44" A.F.F
ELECTRICAL SWITCH HEIGHTS (U.N.O)
SWITCH - 44" A.F.F
THERMOSTAT REMOTE - 48" A.F.F MAX TO TOP OF SWITCH
JUNCTION BOX
DOOR BELL HARDWIRED TO DOORBELL LIGHT - MOUNT @ 46" A.F.F TO CENTER OF BUTTON (FOR COMMUNICATIONS FEATURES ROOMS ONLY)
SD
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216UNIT PLAN - DOUBLEQUEEN STUDIOENLARGED - ELEC,DATA & FLOOR FINISHPLANA-422A
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
0'1' 2'4'
SCALE: 1/2" = 1'-0"
1/2" = 1'-0"1
DOUBLE QUEEN STUDIO ENLARGED UNIT ELECTRICAL & DATAPLAN
Units 212, 312, 412
1/2" = 1'-0"2
DOUBLE QUEEN STUDIO ENLARGED FLOOR AND WALL FINISHPLAN
Units 212, 312, 412
15
10
12
8
9
11
13
14
16
3
KEYNOTES - UNIT PLANS
1 ALIGN
2 GENERAL CONTRACTOR TO COORDINATE W/ FURNITUREFABRICATOR WHERE NECESSARY TO PROVIDE PROPERBLOCKING IN WALL FOR ITEM KEYNOTED
3 NO FINISHES UNDER THE SHOWER PAN / TUB
4 NO FINISHES UNDER MILLWORK CABINETRY
5 TV AND MOUNT NOT TO PROJECT MORE THAN 4" FROMWALL
6 MOTORIZED BLINDS. PROVIDE JUNCTION BOX BEHINDVALENCE FOR POWER CONNECTION AND PERMANENTLYINSTALLED SWITCH ON WALL TO CONTROL BLINDS.
7 SWITCH CONTROLLING UNDER CABINET LIGHTING ATKITCHEN TO BE GANGED WITH LIGHTING AT ENTRY
8 SWITCH CONTROLLING GARBAGE DISPOSAL-REFER TOHADG FOR ACCESSIBLE ROOM REQ'S.
9 DEDICATED CIRCUIT FOR GARBAGE DISPOSAL
10 MASTER SWITCH
11 DEDICATED CIRCUIT FOR INDUCTION COOKTOP
12 DEDICATED CIRCUIT FOR DISHWASHER
13 DEDICATED CIRCUIT FOR REFRIGERATOR
14 ELECTRIC VANITY MIRROR - HARDWIRE FIXTURE TO WALL-CONTRACTOR TO VERIFY JBOX TYPE TO ENSURE PROPERINSTALLATION AND BACKING FOR ITEM KEYNOTED
15 DOORBELL AND DOORBELL ON/OFF SWITCH(COMMUNICATION FEATURES ROOMS ONLY)SIGNAGE ASREQ'D.
16 PLACE TV OUTLETS AND CONNECTIONS ON WALL OUTSIDEAREA OF BRACKET AND CONCEALED FROM VIEW BY TV
17 DEDICATED CIRCUIT FOR WASHER/DRYER. DIRECT VENTTO EXTERIOR
FURNISHING SCHEDULE
GUESTROOM FURNISHINGS
GR-101 CHAIR - LOUNGE CHAIR IN STUIDOS
GR-103 CHAIR - KITCHEN STOOL
GR-105 SOFA - SLEEP BETWEEN ARMS
GR-201 SCONCE - NIGHTSTAND
GR-205 LAMP - FLOOR LAMP
GR-206 LAMP - DOUBLE QUEEN READING LAMP
GR-308 NIGHTSTAND - REGULAR
GR-312 TABLE - NESTING
GR-313 TABLE - ROUND SIDE TABLE
GR-314 TABLE - PRODUCTIVITY TABLE (STUDIO)
GR-318 DRESSER - HIGHBOY
GR-321 CLOSET - KING STUDIO SUITE
GR-326 VANITY - STUDIO AND 1-BEDROOM SUITES
GR-400 STATIC DRAPARY PANELS
GR-503 ART- ENTRY
GR-506 MIRROR - GUESTROOM FULL LENGTH
GR-508 MIRROR - GUESTROOM VANITY
GR-800 KITCHENETTE - 1-BEDROOM
GR-900 GUESTROOM REFRIGERATOR
GR-901 GUESTROOM DISHWASHER
GR-902 GUESTROOM COOKTOP - 2 BURNER
GR-904 GARBAGE DISPOSAL 1/3HP
GR-906GR-911 TELEVISION & TELEVISION MOUNT
GR-907 CLOCK/RADIO
GR-908 TELEPHONE - GUESTROOM
GR-QS BED - QUEEN (GR-302, 305, 601)
PLUMBING/MECHANICAL FIXTURES
PF-01 TOILET - GUESTROOM
PF-03 SHOWER BASE - 60" X 36" WITH LINEARDRAIN
PF-07 LAVATORY - UNDERMOUNT, 20" X 14"
PF-11 SHOWER HEAD - 2 IN 1
PF-13 SHOWER/TUB VALVE & CONTROL
PF-15 FAUCET - LAVATORY
PF-40 SINK - KITCHENETTE
PF-41 FAUCET - KITCHENETTE
TOILET ACCESSORIES
HD-01 DUAL TOILET PAPER HOLDER
HD-04.1 TOWEL BAR
HD-05.2 SLIDING SHOWER DOOR
HD-08 18" GRAB BAR
HD-16 BULK AMENITY DISPENSER ATSHOWERS/TUBS
HD-18 FOOT LEDGE FOR SHOWER
HD-18.1 SOAP SHELF
HD-21 BULK AMENITY DISPENSER AT LAVATORIES
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
Revision Schedule
Number Description Date
TV
WC-01
RB-015' - 1"2' - 3 1/2"
SS-01
WD-01
D-G01
GR-505
0' - 8"
WD-01
RB-01
WC-01
WC-01
RB-01WC-01 RB-01
WD-01WD-01
4' - 2"5' - 5 1/4"
GR-403
?
SF-01
RB-01
W-G
GR-412
PT-03
16
A-510
Sim
WC-01WC-01
RB-01 RB-01
3' - 3 3/4"5' - 2"1' - 10 1/2"
D-G03
PLANELEV
DUPLEX OUTLET
QUADPLEX OUTLET
GFCI OUTLET
CAT6, RJ45 INTERNET OUTLET
TELEPHONE OUTLET
WALL MOUNTED WIRELESS THERMOSTAT
POWER OUTLET WITH USB PORTS
CATV OUTLET
ELECTRICAL SWITCH
FLOOR OUTLET
POWER AND SIGNAL LEGEND:
POWER SUPPLY
JUNCTION BOX
DOOR BELL HARDWIRED TO DOORBELL LIGHT - MOUNT @ 46" A.F.F TO CENTER OF BUTTON (FOR COMMUNICATIONS FEATURES ROOMS ONLY)
CEILING FIXTURE LEGEND:
6" RECESSED CAN DOWNLIGHT
DECORATIVE FLUSH MOUNT LIGHT
PENDENT TYPE SPRINKLERS
SMOKE DETECTOR
EXHAUST FAN / GRILLE
LINEAR SURFACE MOUNTED CONTINUOUS LED SYSTEM W/ FIXED MOUNTING CLIPS & FROSTED LENS / 3 WATTS PER FOOT, MLV/FWD
ELECTRICAL OUTLET HEIGHTS (U.N.O)
TYPICAL OUTLET - 15" A.F.F
TYPICAL ACCESSIBLE WALL OUTLET - 18" A.F.F
BATHROOM VANITY OUTLET - 42" A.F.F
TYP. KITCHEN OUTLET - 42" A.F.F
ADA KITCHEN OUTLET - 46" A.F.F
ADA BATHROOM VANITY OUTLET - 44" A.F.F
ELECTRICAL SWITCH HEIGHTS (U.N.O)
SWITCH - 44" A.F.F
THERMOSTAT REMOTE - 48" A.F.F MAX TO TOP OF SWITCH
SD
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216UNIT INT. ELEVATION -DOUBLE QUEEN STUDIOENLARGED
A-422B
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
FFL
FFL
1/2" = 1'-0" Reference: 1 / A-422
1DOUBLE QUEEN STUDIO ENLARGED ELEVATION A
Units 212, 312, 412 1/2" = 1'-0" Reference: 1 / A-422
2DOUBLE QUEEN STUDIO ENLARGED ELEVATION B
Units 212, 312, 412
1/2" = 1'-0" Reference: 1 / A-422
3DOUBLE QUEEN STUDIO ENLARGED ELEVATION C
Units 212, 312, 412 1/2" = 1'-0" Reference: 1 / A-422
4DOUBLE QUEEN STUDIO ENLARGED ELEVATION D
Units 212, 312, 412
FURNISHING SCHEDULE
GUESTROOM FURNISHINGS
GR-101 CHAIR - LOUNGE CHAIR IN STUIDOS
GR-103 CHAIR - KITCHEN STOOL
GR-105 SOFA - SLEEP BETWEEN ARMS
GR-201 SCONCE - NIGHTSTAND
GR-203 PENDANT LIGHT - PRODUCTIVITY TABLE
GR-205 LAMP - FLOOR LAMP
GR-206 LAMP - DOUBLE QUEEN READING LAMP
GR-307 NIGHTSTAND - SMALL
GR-308 NIGHTSTAND - REGULAR
GR-312 TABLE - NESTING
GR-313 TABLE - ROUND SIDE TABLE
GR-314 TABLE - PRODUCTIVITY TABLE (STUDIO)
GR-318 DRESSER - HIGHBOY
GR-321 CLOSET - KING STUDIO SUITE
GR-326 VANITY - STUDIO AND 1-BEDROOM SUITES
GR-400 STATIC DRAPARY PANELS
GR-403 ROLLER SHADE - GUESTROOMS (MANUAL,SHEER/BLACK-OUT, 8' W)
GR-412 VALENCE FOR 8' WINDOW
GR-503 ART- ENTRY
GR-504 ART- SLEEPING/LIVING
GR-505 WALL HOOK
GR-506 MIRROR - GUESTROOM FULL LENGTH
GR-508 MIRROR - GUESTROOM VANITY
FURNISHING SCHEDULE
GR-800 KITCHENETTE - 1-BEDROOM
GR-900 GUESTROOM REFRIGERATOR
GR-901 GUESTROOM DISHWASHER
GR-902 GUESTROOM COOKTOP - 2 BURNER
GR-904 GARBAGE DISPOSAL 1/3HP
GR-905 MICROWAVE- WITH RECIRCULATING HOOD
GR-906GR-911 TELEVISION & TELEVISION MOUNT
GR-907 CLOCK/RADIO
GR-908 TELEPHONE - GUESTROOM
GR-QS BED - QUEEN (GR-302, 305, 601)
OWNER SPECIFIED - OWNER FURNISHED
OP-706 FIRE EXTINGUISHER CABINET
PLUMBING/MECHANICAL FIXTURES
PF-01 TOILET - GUESTROOM
PF-03 SHOWER BASE - 60" X 36" WITH LINEAR DRAIN
PF-07 LAVATORY - UNDERMOUNT, 20" X 14"
PF-11 SHOWER HEAD - 2 IN 1
PF-13 SHOWER/TUB VALVE & CONTROL
PF-15 FAUCET - LAVATORY
PF-40 SINK - KITCHENETTE
PF-41 FAUCET - KITCHENETTE
FURNISHING SCHEDULE
TOILET ACCESSORIES
HD-01 DUAL TOILET PAPER HOLDER
HD-04 WALL-MOUNTED ROBE HOOK
HD-04.1 TOWEL BAR
HD-05.2 SLIDING SHOWER DOOR
HD-08 18" GRAB BAR
HD-16 BULK AMENITY DISPENSER AT SHOWERS/TUBS
HD-18 FOOT LEDGE FOR SHOWER
HD-18.1 SOAP SHELF
HD-21 BULK AMENITY DISPENSER AT LAVATORIES
KEYNOTES - UNIT PLANS
1 ALIGN
2 GENERAL CONTRACTOR TO COORDINATE W/ FURNITUREFABRICATOR WHERE NECESSARY TO PROVIDE PROPERBLOCKING IN WALL FOR ITEM KEYNOTED
3 NO FINISHES UNDER THE SHOWER PAN / TUB
4 NO FINISHES UNDER MILLWORK CABINETRY
5 TV AND MOUNT NOT TO PROJECT MORE THAN 4" FROMWALL
6 MOTORIZED BLINDS. PROVIDE JUNCTION BOX BEHINDVALENCE FOR POWER CONNECTION AND PERMANENTLYINSTALLED SWITCH ON WALL TO CONTROL BLINDS.
7 SWITCH CONTROLLING UNDER CABINET LIGHTING ATKITCHEN TO BE GANGED WITH LIGHTING AT ENTRY
8 SWITCH CONTROLLING GARBAGE DISPOSAL-REFER TOHADG FOR ACCESSIBLE ROOM REQ'S.
9 DEDICATED CIRCUIT FOR GARBAGE DISPOSAL
10 MASTER SWITCH
11 DEDICATED CIRCUIT FOR INDUCTION COOKTOP
12 DEDICATED CIRCUIT FOR DISHWASHER
13 DEDICATED CIRCUIT FOR REFRIGERATOR
14 ELECTRIC VANITY MIRROR - HARDWIRE FIXTURE TO WALL-CONTRACTOR TO VERIFY JBOX TYPE TO ENSURE PROPERINSTALLATION AND BACKING FOR ITEM KEYNOTED
15 DOORBELL AND DOORBELL ON/OFF SWITCH(COMMUNICATION FEATURES ROOMS ONLY)SIGNAGE ASREQ'D.
16 PLACE TV OUTLETS AND CONNECTIONS ON WALL OUTSIDEAREA OF BRACKET AND CONCEALED FROM VIEW BY TV
17 DEDICATED CIRCUIT FOR WASHER/DRYER. DIRECT VENTTO EXTERIOR
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
Revision Schedule
Number Description Date
TV
A-4235
3
8
6
A-423
4
72' - 3"2' - 3"GR-325
GR-506
6' - 1"7' - 5"3' - 8 3/4"3' - 1"5' - 4"6' - 6 3/4"HD-01
GR-319
HD-08
HD-16
HD-18
14' - 3"HD-21
VERIFY SHOWER PAN DIMENSIONS
5' - 0"
A-5103
A-5105Sim
PF-01
PF-07
PF-15
PF-11
PF-03
?
HD-12
HD-18.1
4' - 0 1/2" TOP OF SOAP SHELFHD-18
HD-08
HD-04
WC-02
7' - 6"1' - 3"4
A-510
HD-16
CT-01.17' - 6"PF-03
PF-11
PF-13
1' - 5"1' - 5"3' - 3"3' - 6"EQEQ
WC-01
WC-02
HD-08
GR-506
GR-325
SAFE
GR-319
HD-21
3' - 5 1/2"2' - 9"
CT-01.1
J
3
A-710 7' - 6"2' - 6"PF-11
PF-13
HD-04
PF-03
PF-01
CT-01.1
PF-15
1' - 9"2' - 0"
HD-01
D-G03
PT-03WC-02
CT-01.1
EQEQ
7' - 6"PF-01
OPEN TO ROOM
EQ EQ
HD-16
HD-18
CT-01.1
WC-02WC-01
CT-01.17' - 6"GR-319
PF-03
2' - 9"3' - 0"3' - 6"1' - 5"0' - 5"
CT-01.1
PT-03
D-G037' - 6"GR-325
GR-506
HD-21
WC-01
PF-15
SAFE
GR-319
CT-01.1
WC-02
7' - 6"DOOR
VANITY
1' - 2 1/2"
WALL
3' - 0"0' - 2 1/2"1' - 0 1/2"
CL-B27' - 6"
CL-B27' - 6"
WALL
WALL
PLAN ELEV
DUPLEX OUTLET
QUADPLEX OUTLET
GFCI OUTLET
CAT6, RJ45 INTERNET OUTLET
TELEPHONE OUTLET
WALL MOUNTED WIRELESS THERMOSTAT
POWER OUTLET WITH USB PORTS
CATV OUTLET
ELECTRICAL SWITCH
FLOOR OUTLET
POWER AND SIGNAL LEGEND:
POWER SUPPLY
CEILING FIXTURE LEGEND:
6" RECESSED CAN DOWNLIGHT
DECORATIVE FLUSH MOUNT LIGHT
PENDENT TYPE SPRINKLERS
SMOKE DETECTOR
EXHAUST FAN / GRILLE
LINEAR SURFACE MOUNTED CONTINUOUS LED SYSTEM W/ FIXED MOUNTING CLIPS & FROSTED LENS / 3 WATTS PER FOOT, MLV/FWD
ELECTRICAL OUTLET HEIGHTS (U.N.O)
TYPICAL OUTLET - 15" A.F.F
TYPICAL ACCESSIBLE WALL OUTLET - 18" A.F.F
BATHROOM VANITY OUTLET - 42" A.F.F
TYP. KITCHEN OUTLET - 42" A.F.F
ADA KITCHEN OUTLET - 46" A.F.F
ADA BATHROOM VANITY OUTLET - 44" A.F.F
ELECTRICAL SWITCH HEIGHTS (U.N.O)
SWITCH - 44" A.F.F
THERMOSTAT REMOTE - 48" A.F.F MAX TO TOP OF SWITCH
JUNCTION BOX
DOOR BELL HARDWIRED TO DOORBELL LIGHT - MOUNT @ 46" A.F.F TO CENTER OF BUTTON (FOR COMMUNICATIONS FEATURES ROOMS ONLY)
SD
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216UNIT BATH -EFFICIENCY BATHPLANS AND INTERIORELEVATIONS
A-423
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
1/2" = 1'-0" Reference: 1 / A-411
1EFFICIENCY BATHROOM PLAN
Units x05, 307, 407, 507, x08, x27-x29, x31, x33-x34
FFL
1/2" = 1'-0" Reference: 1 / A-423
3EFFICIENCY BATH ELEV. A
Units x05, 307, 407, 507, x08, x27-x29, x31, x33-x34
1/2" = 1'-0" Reference: 1 / A-423
5EFFICIENCY BATH ELEV. B
Units x05, 307, 407, 507, x08, x27-x29, x31, x33-x34
1/2" = 1'-0" Reference: 1 / A-423
6EFFICIENCY BATH ELEV. C
Units x05, 307, 407, 507, x08, x27-x29, x31, x33-x34
1/2" = 1'-0" Reference: 1 / A-423
8EFFICIENCY BATH ELEV. D
Units x05, 307, 407, 507, x08, x27-x29, x31, x33-x34
1/2" = 1'-0" Reference: 1 / A-423
4 EFFICIENCY BATH ELEV. A1
Units x05, 307, 407, 507, x08, x27-x29, x31, x33-x34
1/2" = 1'-0" Reference: 1 / A-423
7EFFICIENCY BATH ELEV. C1
Units x05, 307, 407, 507, x08, x27-x29, x31, x33-x34
KEYNOTES - UNIT BATHROOMS
1 WALL MOUNTED GRAB BARS REQUIREDCLEARANCES - 12" ABOVEAND 1-1/2" BELOW. REFER TO ACCESSIBILITYSTANDARDS & HADG
2 CURTAIN ROD
3 ACCESSIBLE SHOWER THRESHOLD. 1/2" MAXHEIGHT BEVELED 1:2 MAX. REFER TO HADG FORMORE INFORMATION
4 TOWEL/ROBE HOOK
5 DOUBLE TOILET PAPER HOLDER
6 ACCESSIBLE VANITY
7 ACCESSIBLE TUB/SHOWER SEAT. REFER TOACCESSIBILITY STANDARDS AND HADG FORREQUIREMENTS
8 CLEAR AREA OF SINK/VANITY MUST BEACCESSIBLE
9 ON/OFF - PRESSURE BALANCING VALVE ANDTEMPERATURE CONTROL.
10 SHOWER HEAD. "TWO-IN-ONE" SHOWER HEADWITH STATIONARY SHOWER HEAD PORTION ANDREMOVABLE HAND HELD SHOWER WAND
11 SHOWER DIVERTER VALVE
12 HAND SHOWER. HAND-HELD SHOWER UNITREQUIRED TO HAVE ON/OFF CONTROL WITHNON-POSITIVE SHUT OFF
13 VANITY LIGHTED MIRROR FIXTURE -- HARDWIREFIXTURE TO WALL- CONTRACTOR TO VERIFY JBOXTYPE TO ENSURE PROPER INSTALLATION ANDBACKING FOR ITEM KEYNOTED
14 GFCI OUTLETS
15 CORNER SOAP SHELF
17 BULK TOILETRY DISPENSERS
18 SHOWER ENCLOSURE W/ TEMPERED GLASS DOOR.
19 TOWEL BAR ON SHOWER SURROUND
20 FLOOR DRAIN LOCATION -- MAINTAIN ACCESSIBLECOMPLIANT SLOPES TO DRAIN
21 ADA ROLL-IN SHOWER BASE
22 FRAMING SUBCONTRACTOR TO PROVIDE 3/4" F.R.T.PLYWOOD BLOCKING TO RECEIVE ITEM INDICATED- EXTEND FULL LENGTH OF OBJECT
23 SHOWER SURROUND
24 TOILET
25 SHOWER BASE WITH LINEAR DRAIN
26 LAVATORY
27 FAUCET
28 GRAB BAR
29 BATHTUB
30 TUB FILL FAUCET
31 TOILET FLUSH HANDLE TO BE LOCATED ONAPPROACH SIDE
32 TOWEL BAR
33 IRON AND IRONING BOARD HANGER
34 CLOSET
35 BATH CADDY
36 SOAP DISH
37 FACIAL TISSUE COVER
38 SHAFT
39 WALL STOP
40 ALIGN
41 STATIONARY SHOWER HEAD.
40
24
22
13 22
24
31
38
13
22
22
26
34
19
18
5
5
24
10
22
34
33
2822
25
15
9
25
10
15
2822
4
17
36
37
27
17
17
22
23
40
2822
4
9
15
10
25
33
33
34
17
14
27
FFL
FFL
0'1' 2'4'
SCALE: 1/2" = 1'-0"
34
3322
23
25
23
40
17
18
27
1/2" = 1'-0" Reference: 2 / A-411
2EFFICIENCY BATHROOM RCP
Units x05, 307, 407, 507, x08, x27-x29, x31, x33-x34
4
22
40
40
39
10.OBJECTS MOUNTED WITHIN THE CIRCULATION PATHIN ACCESSIBLE ROOMS BETWEEN 27" AND 80" AFFSHALL NOT PROTRUDE FURTHER THAN 4" FROM WALL- REFER TO HADM FOR FURTHER REQUIREMENTS.
9. OBJECTS MOUNTED WITHIN THE CIRCULATION PATHIN ACCESSIBLE ROOMS BETWEEN 27" AND 80" AFFSHALL NOT PROTRUDE FURTHER THAN 4" FROM WALL- REFER TO HADM FOR FURTHER REQUIREMENTS.
8. IN ACCESSIBLE ROOMS AT LEAST ONE OUTLET ANDDATA CONNECTION FOR USE BY GUESTS MUST BEMOUNTED BETWEEN 15" AND 48" AFF AND PROVIDE ACLEAR FLOOR AREA IN COMPLIANCE WITH...
7. ROOMS WITH COMMUNICATION DEVICES SHALL BEEQUIPPED WITH ACCESSIBLE DEVICES SUCH AS, BUTNOT LIMITED TO THE FOLLOWING: FIRE ALARMSTROBES, SMOKE DETECTOR STROBES AND DOORBUZZER STROBES, TELEPHONES WITH VOLUME...
6. ROOMS WITH COMMUNICATION DEVICES SHALL BEEQUIPPED WITH ACCESSIBLE DEVICES SUCH AS, BUTNOT LIMITED TO THE FOLLOWING: FIRE ALARMSTROBES, SMOKE DETECTOR STROBES AND DOORBUZZER STROBES, TELEPHONES WITH VOLUME...
5. CEILING MOUNTED LIGHT FIXTURE AND EXHAUST FANAT ALL GUESTROOM BATHS TO BE SWITCHEDSEPARATELY.
4. ELECTRICAL OUTLETS AT DESKS & NIGHTSTANDSARE TO BE COORDINATED WITH HOMEWOOD...
3. HEIGHT OF ALL SWITCHES, OUTLETS, ETC., TO MEETACCESSIBILITY STANDARDS FOR MAXIMUM ANDMINIMUM REACH RANGE. FEDERAL AND LOCALCODES APPLY AND THE MOST STRINGENT STANDARDPREVAILS. SWITCHES ON LAMPS MUST BE TOGGLE...
2. LIGHT SWITCH AND G.F.I. OUTLETS CAN BE MOUNTEDIN A COMMON BOX WITH COVER PLATE. COORDINAT...
1. AT WALLS BETWEEN ADJACENT ROOMS, ELECTRICALOUTLET OCATIONS, INCLUDING TV AND TELEPHONEOUTLETS, SHALL BE OFFSET 6" MIN. HORIZONTALLYFOR INSTALLATION. ELECTRICAL CORDS SHOULD BEHIDDEN FROM VIEW. BACK TO BACK OUTLETS ARE...
GENERAL NOTES - UNITS
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
Revision Schedule
Number Description Date
ATV
A-4246
5
4
CT-01D-G03A12' - 1 3/4"HD-16PF-10
HD-08
PF-12
HD-20
HD-05
PF-06
PF-01
HD-11
P1.1
P1.1
HD-04.1
HD-02
HD-11.1
GR-3281' - 3"
VERIFY BATHTUB DIMENSIONS
5' - 0"
7' - 2"
PF-07
GR-507
PF-15
4' - 9"HD-21
HD-04
HD-122' - 0"3' - 1"2' - 1"
HD-10
HD-09HD-14.1HD-18.1
GR-327
WC-02
7' - 3 1/2"0' - 9 1/4"
CT-01.1
HD-02
0' - 5 3/4"
HD-08
HD-11.1
HD-05
PF-13
HD-10
PF-10
HD-08
PF-06
PF-14
PF-12
GR-507
GR-327
J
PF-15
2' - 10"3' - 4"3' - 8"HD-11
PF-01
0' - 8"1' - 9"2' - 10"3' - 3"3' - 4"7' - 6"WC-02
0' - 8"CT-01.1
PF-10
PF-15
HD-09
HD-16
GR-507
HD-05
HD-04
HD-08
PF-06
GR-327HD-14.1
4
A-510
HD-12
3' - 8"WC-02
CT-01.1
PL-02PT-03
D-G03A
HD-04
HD-20
HD-16
HD-04.1
HD-05
PF-06
HD-09
HD-14.14' - 0"3' - 11"GR-328
VANITY
WALL
WALL
0' - 1"1' - 8"1' - 8"EQ EQ3' - 1"CL-B27' - 6"
PLAN ELEV
DUPLEX OUTLET
QUADPLEX OUTLET
GFCI OUTLET
CAT6, RJ45 INTERNET OUTLET
TELEPHONE OUTLET
WALL MOUNTED WIRELESS THERMOSTAT
POWER OUTLET WITH USB PORTS
CATV OUTLET
ELECTRICAL SWITCH
FLOOR OUTLET
POWER AND SIGNAL LEGEND:
POWER SUPPLY
CEILING FIXTURE LEGEND:
6" RECESSED CAN DOWNLIGHT
DECORATIVE FLUSH MOUNT LIGHT
PENDENT TYPE SPRINKLERS
SMOKE DETECTOR
EXHAUST FAN / GRILLE
LINEAR SURFACE MOUNTED CONTINUOUS LED SYSTEM W/ FIXED MOUNTING CLIPS & FROSTED LENS / 3 WATTS PER FOOT, MLV/FWD
ELECTRICAL OUTLET HEIGHTS (U.N.O)
TYPICAL OUTLET - 15" A.F.F
TYPICAL ACCESSIBLE WALL OUTLET - 18" A.F.F
BATHROOM VANITY OUTLET - 42" A.F.F
TYP. KITCHEN OUTLET - 42" A.F.F
ADA KITCHEN OUTLET - 46" A.F.F
ADA BATHROOM VANITY OUTLET - 44" A.F.F
ELECTRICAL SWITCH HEIGHTS (U.N.O)
SWITCH - 44" A.F.F
THERMOSTAT REMOTE - 48" A.F.F MAX TO TOP OF SWITCH
JUNCTION BOX
DOOR BELL HARDWIRED TO DOORBELL LIGHT - MOUNT @ 46" A.F.F TO CENTER OF BUTTON (FOR COMMUNICATIONS FEATURES ROOMS ONLY)
SD
VERIFY SHOWER PAN DIMENSIONS
5' - 0"
7' - 2"
PF-13
HD-14
PF-12HD-16HD-11
HD-18.1
HD-09
HD-21
HD-04
PF-04PF-07
GR-507
PF-15
GR-327
PF-01
HD-11
P1.1
P1.1
HD-04.1
HD-12
HD-02
HD-11.1
GR-3281' - 3"
PF-10
A-4249
8
7
10
D-G03A
CT-012' - 0"2' - 1"4' - 9"HD-05.1EQ.EQ.6' - 9" MIN. TO BTM. OF SHOWER HEADPF-04
HD-18.1
HD-11
HD-09
PF-10
HD-16
HD-05.1
3' - 0"4' - 0"2' - 10"3' - 4"3' - 8"2' - 10"3' - 3"0' - 8"1' - 9"PF-01
HD-11
HD-11.1
HD-08
GR-507
HD-21
WC-02
CT-01.1
J
GR-327
WC-02
CT-01.1 7' - 6"GR-328
HD-04.1
PF-01
HD-02
HD-11.1
HD-08
HD-11
4' - 0"GR-328
HD-04.1
HD-05.1
HD-16
HD-14
PF-12
PF-04
HD-04WC-02
CT-01.1
D-G03A
PT-03PL-02
HD-14
HD-16
HD-11
PF-13
HD-04
PF-12
HD-05.1
PF-10
GR-507
HD-21
PF-15
PF-07
GR-327
CT-01.1
WC-02
PF-04
HD-18.1
A-710
2Sim
4
A-510
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216UNIT BATH-ACCESSIBLE BATHPLANS AND INTERIORELEVATIONS
A-424
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
FFL
1/2" = 1'-0" Reference: 1 / A-415
2ADA BATHTUB PLAN
Units 138, 238, 303, 503, 512
1/2" = 1'-0" Reference: 2 / A-415A
6ADA BATHTUB ELEV. B
Units 138, 238, 303, 503, 512
1/2" = 1'-0" Reference: 2 / A-415A
5ADA BATHTUB ELEV. A
Units 138, 238, 303, 503, 512 1/2" = 1'-0" Reference: 2 / A-415A
4ADA BATHTUB ELEV. D
Units 138, 238, 303, 503, 512
FFL
1/2" = 1'-0" Reference: 2 / A-412
3ADA BATH RCP
Units 138, 238, 303, 503, 512
36
37
38
17
17
27
1
13 22
14
5
24
27
23
9
234
4
10
27
15
10
15
3
28
10
1322
2228
4
28
28
10
17
6
1322
22
4
KEYNOTES - UNIT BATHROOMS
1 WALL MOUNTED GRAB BARS REQUIREDCLEARANCES - 12" ABOVEAND 1-1/2" BELOW. REFER TO ACCESSIBILITYSTANDARDS & HADG
2 CURTAIN ROD
3 ACCESSIBLE SHOWER THRESHOLD. 1/2" MAXHEIGHT BEVELED 1:2 MAX. REFER TO HADG FORMORE INFORMATION
4 TOWEL/ROBE HOOK
5 DOUBLE TOILET PAPER HOLDER
6 ACCESSIBLE VANITY
7 ACCESSIBLE TUB/SHOWER SEAT. REFER TOACCESSIBILITY STANDARDS AND HADG FORREQUIREMENTS
8 CLEAR AREA OF SINK/VANITY MUST BEACCESSIBLE
9 ON/OFF - PRESSURE BALANCING VALVE ANDTEMPERATURE CONTROL.
10 SHOWER HEAD. "TWO-IN-ONE" SHOWER HEADWITH STATIONARY SHOWER HEAD PORTION ANDREMOVABLE HAND HELD SHOWER WAND
11 SHOWER DIVERTER VALVE
12 HAND SHOWER. HAND-HELD SHOWER UNITREQUIRED TO HAVE ON/OFF CONTROL WITHNON-POSITIVE SHUT OFF
13 VANITY LIGHTED MIRROR FIXTURE -- HARDWIREFIXTURE TO WALL- CONTRACTOR TO VERIFY JBOXTYPE TO ENSURE PROPER INSTALLATION ANDBACKING FOR ITEM KEYNOTED
14 GFCI OUTLETS
15 CORNER SOAP SHELF
17 BULK TOILETRY DISPENSERS
18 SHOWER ENCLOSURE W/ TEMPERED GLASS DOOR.
19 TOWEL BAR ON SHOWER SURROUND
20 FLOOR DRAIN LOCATION -- MAINTAIN ACCESSIBLECOMPLIANT SLOPES TO DRAIN
21 ADA ROLL-IN SHOWER BASE
22 FRAMING SUBCONTRACTOR TO PROVIDE 3/4" F.R.T.PLYWOOD BLOCKING TO RECEIVE ITEM INDICATED- EXTEND FULL LENGTH OF OBJECT
23 SHOWER SURROUND
24 TOILET
25 SHOWER BASE WITH LINEAR DRAIN
26 LAVATORY
27 FAUCET
28 GRAB BAR
29 BATHTUB
30 TUB FILL FAUCET
31 TOILET FLUSH HANDLE TO BE LOCATED ONAPPROACH SIDE
32 TOWEL BAR
33 IRON AND IRONING BOARD HANGER
34 CLOSET
35 BATH CADDY
36 SOAP DISH
37 FACIAL TISSUE COVER
38 SHAFT
39 WALL STOP
40 ALIGN
41 STATIONARY SHOWER HEAD.
10.OBJECTS MOUNTED WITHIN THE CIRCULATION PATHIN ACCESSIBLE ROOMS BETWEEN 27" AND 80" AFFSHALL NOT PROTRUDE FURTHER THAN 4" FROM WALL- REFER TO HADM FOR FURTHER REQUIREMENTS.
9. OBJECTS MOUNTED WITHIN THE CIRCULATION PATHIN ACCESSIBLE ROOMS BETWEEN 27" AND 80" AFFSHALL NOT PROTRUDE FURTHER THAN 4" FROM WALL- REFER TO HADM FOR FURTHER REQUIREMENTS.
8. IN ACCESSIBLE ROOMS AT LEAST ONE OUTLET ANDDATA CONNECTION FOR USE BY GUESTS MUST BEMOUNTED BETWEEN 15" AND 48" AFF AND PROVIDE ACLEAR FLOOR AREA IN COMPLIANCE WITH...
7. ROOMS WITH COMMUNICATION DEVICES SHALL BEEQUIPPED WITH ACCESSIBLE DEVICES SUCH AS, BUTNOT LIMITED TO THE FOLLOWING: FIRE ALARMSTROBES, SMOKE DETECTOR STROBES AND DOORBUZZER STROBES, TELEPHONES WITH VOLUME...
6. ROOMS WITH COMMUNICATION DEVICES SHALL BEEQUIPPED WITH ACCESSIBLE DEVICES SUCH AS, BUTNOT LIMITED TO THE FOLLOWING: FIRE ALARMSTROBES, SMOKE DETECTOR STROBES AND DOORBUZZER STROBES, TELEPHONES WITH VOLUME...
5. CEILING MOUNTED LIGHT FIXTURE AND EXHAUST FANAT ALL GUESTROOM BATHS TO BE SWITCHEDSEPARATELY.
4. ELECTRICAL OUTLETS AT DESKS & NIGHTSTANDSARE TO BE COORDINATED WITH HOMEWOOD...
3. HEIGHT OF ALL SWITCHES, OUTLETS, ETC., TO MEETACCESSIBILITY STANDARDS FOR MAXIMUM ANDMINIMUM REACH RANGE. FEDERAL AND LOCALCODES APPLY AND THE MOST STRINGENT STANDARDPREVAILS. SWITCHES ON LAMPS MUST BE TOGGLE...
2. LIGHT SWITCH AND G.F.I. OUTLETS CAN BE MOUNTEDIN A COMMON BOX WITH COVER PLATE. COORDINAT...
1. AT WALLS BETWEEN ADJACENT ROOMS, ELECTRICALOUTLET OCATIONS, INCLUDING TV AND TELEPHONEOUTLETS, SHALL BE OFFSET 6" MIN. HORIZONTALLYFOR INSTALLATION. ELECTRICAL CORDS SHOULD BEHIDDEN FROM VIEW. BACK TO BACK OUTLETS ARE...
GENERAL NOTES - UNITS
1/2" = 1'-0" Reference: 1 / A-412
1ADA ROLL-IN SHOWER PLAN
Units 338, 403
38
22
27
36
37
5
24
31
15
4
32
9
26
17
28
13
35
4
221
28221
20
5
24
31
32
28
35
4
221
28221
22
27
26
17
13
41
28221
282211712
1/2" = 1'-0" Reference: 1 / A-424
9ADA ROLL-IN SHOWER ELEV. D
Units 338, 403
1/2" = 1'-0" Reference: 1 / A-424
10 ADA BATH ELEV. C
Units 138, 238, 303, 503, 512
41
12
28221
28221
28221
221
221
8
7
7
2
686
11
29
15
28
22
1
17
2
23 13 22
24
14
17
1/2" = 1'-0" Reference: 1 / A-424
7ADA ROLL-IN SHOWER ELEV. B
Units 338, 403
35
32
28
22
1
24
5
4
23
2
12
7
17
3
32
35
28
22
1
17
0'1' 2'4'
SCALE: 1/2" = 1'-0"
321
1
7
29
2
2822
2822
35
3
2121
29
2
1
2228
6
1/2" = 1'-0" Reference: 1 / A-424
8ADA ROLL-IN SHOWER ELEV. A
Units 338, 403
2
12
4
9
28
17
7
21
221
3
23
7
29
1
30
221
12
2
28
22
1
86
86
11
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
Revision Schedule
Number Description Date
WC-02
HD-16
CT-01.17' - 6"HD-04
4
A-510
PF-13
PF-03
D-G03
WC-01
PT-03
PL-02
CT-01.1
CT-01.1
WC-02
HD-16
PF-03
GR-506
WC-02
WC-02
GR-326
HD-21PF-15 PF-13
HD-04
PF-03
PF-11
HD-08
HD-18.1
A-4256
4
10
8
A-425
5
94' - 10 3/4"3' - 4"3' - 1 1/4"4' - 0"VER. SHOWER PAN DIMENSIONS
5' - 0"
6' - 1"
A-5105Sim
HD-16
HD-21
HD-01
P1.2P1.1P1.1PF-07
PF-15
GR-506
HD-12
HD-12
4' - 6"PF-016' - 5"EQEQHD-18.1
PF-11
HD-08
HD-18
HD-05.2
D-G03
CT-01
?
D-G03
HD-04.1
EQEQ
EQEQEQ
EQCL-B27' - 6"
CL-B27' - 6"
PT-03
PL-02
WC-02
2' - 0"1' - 9"HD-01
D-G03
℄
PF-01
WC-02
PT-03
PL-02
HD-21
GR-506
CT-01.1
0' - 5"1' - 5"
GR-326
3' - 6"D-G03
GR-506
GR-326
WC-02
CT-01.1
A-42511
12
73' - 1 1/2"3' - 4"4' - 10 3/4"4' - 0"VER. TUB DIMENSIONS
5' - 0"
6' - 1"
HD-16
EQEQHD-12
PF-06
PF-11
HD-08
PF-01
HD-01
HD-21
PF-07
PF-15
GR-506
?
D-G03
D-G03
HD-04.1
HD-12
HD-05
CT-01
P1.1
P1.1
P1.2
WC-02
PF-06
PF-14
HD-08
PF-13
PF-11
HD-05
HD-04
HD-16
CT-01.1
WC-02
CT-01.1
PL-02
PT-03
HD-12
HD-05
WC-01
HD-16
GR-506
GR-326
WC-01
WC-02
PF-11
HD-08
HD-18.1
PF-13
PF-14
PF-06
PF-15
HD-21
HD-05
HD-04
1/2" = 1'-0" Reference: 1 / A-414
4STUDIO BATH ELEV. A
Units x04, x14, x16, x18-x21, x23, x25-x26, x30, x37 1/2" = 1'-0" Reference: 1 / A-425
6STUDIO BATH ELEV. B
Units x04, x14, x16, x18-x21, x23, x25-x26, x30, x37
1/2" = 1'-0" Reference: 1 / A-425
10STUDIO BATH ELEV. D
Units x04, x14, x16, x18-x21, x23, x25-x26, x30, x37
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216UNIT BATH - STUDIOBATH PLANS ANDINTERIOR ELEVATIONS
A-425
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
1/2" = 1'-0" Reference: 1 / A-414
1STUDIO BATHROOM PLAN
Units x04, x14, x16, x18-x21, x23, x25-x26, x30, x37
FFL
1/2" = 1'-0" Reference: 3 / A-414
3STUDIO BATHROOM RCP
Units x04, x14, x16, x18-x21, x23, x25-x26, x30, x37
FFL
1/2" = 1'-0" Reference: 1 / A-414
8STUDIO BATH ELEV. C
Units x04, x14, x16, x18-x26, x30, x36-x37
1/2" = 1'-0" Reference: 1 / A-414
5STUDIO BATH ELEV. A1
Units x04, x14, x16, x18-x26, x30, x36-x37
1/2" = 1'-0" Reference: 1 / A-414
9STUDIO BATH ELEV. C1
Units x04, x14, x16, x18-x26, x30, x36-x37
KEYNOTES - UNIT BATHROOMS
1 WALL MOUNTED GRAB BARS REQUIREDCLEARANCES - 12" ABOVEAND 1-1/2" BELOW. REFER TO ACCESSIBILITYSTANDARDS & HADG
2 CURTAIN ROD
3 ACCESSIBLE SHOWER THRESHOLD. 1/2" MAXHEIGHT BEVELED 1:2 MAX. REFER TO HADG FORMORE INFORMATION
4 TOWEL/ROBE HOOK
5 DOUBLE TOILET PAPER HOLDER
6 ACCESSIBLE VANITY
7 ACCESSIBLE TUB/SHOWER SEAT. REFER TOACCESSIBILITY STANDARDS AND HADG FORREQUIREMENTS
8 CLEAR AREA OF SINK/VANITY MUST BEACCESSIBLE
9 ON/OFF - PRESSURE BALANCING VALVE ANDTEMPERATURE CONTROL.
10 SHOWER HEAD. "TWO-IN-ONE" SHOWER HEADWITH STATIONARY SHOWER HEAD PORTION ANDREMOVABLE HAND HELD SHOWER WAND
11 SHOWER DIVERTER VALVE
12 HAND SHOWER. HAND-HELD SHOWER UNITREQUIRED TO HAVE ON/OFF CONTROL WITHNON-POSITIVE SHUT OFF
13 VANITY LIGHTED MIRROR FIXTURE -- HARDWIREFIXTURE TO WALL- CONTRACTOR TO VERIFY JBOXTYPE TO ENSURE PROPER INSTALLATION ANDBACKING FOR ITEM KEYNOTED
14 GFCI OUTLETS
15 CORNER SOAP SHELF
17 BULK TOILETRY DISPENSERS
18 SHOWER ENCLOSURE W/ TEMPERED GLASS DOOR.
19 TOWEL BAR ON SHOWER SURROUND
20 FLOOR DRAIN LOCATION -- MAINTAIN ACCESSIBLECOMPLIANT SLOPES TO DRAIN
21 ADA ROLL-IN SHOWER BASE
22 FRAMING SUBCONTRACTOR TO PROVIDE 3/4" F.R.T.PLYWOOD BLOCKING TO RECEIVE ITEM INDICATED- EXTEND FULL LENGTH OF OBJECT
23 SHOWER SURROUND
24 TOILET
25 SHOWER BASE WITH LINEAR DRAIN
26 LAVATORY
27 FAUCET
28 GRAB BAR
29 BATHTUB
30 TUB FILL FAUCET
31 TOILET FLUSH HANDLE TO BE LOCATED ONAPPROACH SIDE
32 TOWEL BAR
33 IRON AND IRONING BOARD HANGER
34 CLOSET
35 BATH CADDY
36 SOAP DISH
37 FACIAL TISSUE COVER
38 SHAFT
39 WALL STOP
40 ALIGN
41 STATIONARY SHOWER HEAD.
1/2" = 1'-0" Reference: 1 / A-420
2STUDIO BATHTUB PLAN
Units x22, x24, x36
1/2" = 1'-0" Reference: 2 / A-425
12 STUDIO BATHTUB ELEV. A
Units x22, x24, x36
1/2" = 1'-0" Reference: 2 / A-425
7 STUDIO BATHTUB ELEV. B
Units x22, x24, x36
1/2" = 1'-0" Reference: 2 / A-425
11 STUDIO BATHTUB ELEV. D
Units x22, x24, x36
29
38
1322
4
23
25
17
14
25
18
22
2222
17
24
13 22
22
28
15 232323
2323
17
17
24
5
10
9
4
25
9
10
17
27
4
10
17
2213
13
24
18
17
28
9
10
17
4
25
38
26
36
37
17
31
24
27
17
4
18
5
4
2213
4
19
40
11
15
9
2822
22
26
36
37
17
31
24
27
5
4
2213
11
15
9
2822
324
22
32
40
2
40
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
Revision Schedule
Number Description Date
1' - 9"7" - 9"
TOILET PAPER
ROLL HOLDER
FROM BACK OF WALL
2' - 0"
SINGLE TOILET
PAPER HOLDER
7" - 9"MIN.1' - 3"TOILET TISSUE DISPENSER
HD 01HD 02HD 03U.O.N5' - 6"TOWEL HOOK SURFACE MOUNTED
HD 04
SHOWER CURTAIN ROD
HD 56' - 8" BOWED SHOWER ROD6' - 8" STRAIGHT ROD (ADA SHOWERS ONLY)HD 5.1
3' - 4"
4' - 6"
MIN.
3' - 6"TOILET SEAT HEIGHT1 ' - 5" - 1' - 7"REQ'D CLEAR1' - 0"REQ'D CLEAR0' - 1 1/2"GRIPPING SURFACE2'-9" - 2'-0"MIN.
3' - 0"1'-6" MIN.3'-3" - 3'-5"1' - 5"
3' - 5"
GRAB BAR(TOILET / 2-WALL AND VERTICAL)SURFACE MOUNTED
HD 06
NOTE: TYP. CLEAR AREA AROUND GRAB BARS TO BE : ABOVE - 1'-0", BELOW - 1'-5" . BETWEEN, SHOWER CONTROLS, SHOWER FITTING, AND OTHER GRAB BARS A CLEAR DISTANCE OF 1.5" IS PERMITTED.
MIN.
1' - 0"
MIN.
2' - 0"REFER TO ELEVATIONS30" AFF1' - 6"EDGE OF TUB / SHOWER
BELOW GRAB BAR3" - 6"6" - 12"REQ'D CLEAR0' - 1 1/2"REQ'D CLEAR0' - 1 1/2"LINE OF TUB8" - 10" MAX.FFL
FFLREQ'D CLEAR1' - 0"3'-0" GRIPPING SURFACEGRAB BAR(TUB / SHOWER)SURFACE MTD.
HD 08
MAX.
1' - 0"2' - 0"1' - 10"
NOTE: TYP. CLEAR AREA AROUND GRAB BARS TO BE : ABOVE - 1'-0", BELOW - 1'-5" . BETWEEN, SHOWER CONTROLS, SHOWER FITTING, AND OTHER GRAB BARS A CLEAR DISTANCE OF 1.5" IS PERMITTED.
2 GRAB BARS(TUB )SURFACE MTD.
HD 09
GRAB BAR(TUB )SURFACE MTD.
HD 10
NOTE: ALL GRAB BARS MUST BE BLOCKED OR REINFORCED TO WITHSTAND ACCESSIBILITY REQT'S - REFER TO HADG
REQ'D CLEAR0' - 1 1/2"REQ'D CLEAR1' - 0"T.O. GRIPPING SURFACE3' - 0"MAX.
0' - 6"3' - 0"
GRAB BAR(SHOWER )SURFACE MTD.
HD 11
NOTE: TYP. CLEAR AREA AROUND GRAB BARS TO BE : ABOVE - 1'-0"BELOW - 1'-5"ACC.3' - 4"U.O.N.5' - 0"ROBE HOOKSURFACE MTD.
HD 12
AUTOMATIC PAPER TOWER DISPENSER
HD 13TO SHEET OR TOP OF CONTROL4' - 0"INSTALL BOTH ACC. AND NON ACC. COAT HOOK IN ACC. PUBLIC EMPLOYEE BATH1' - 6"U.O.N3' - 5 1/4"LINE OF WALL
MAX.
0' - 2 1/2"
FOLDING SHOWER SEAT (SURFACE MOUNTED)
HD 14
SOAP DISPENSER POOL RESTROOMS(SURFACE MOUNTED)
HD 15 TO TOP OF BRACKET U.O.N2'-0" ACCESSIBLE SHOWERTYP.
0' - 5 1/2"TO TOP OF BRACKET U.O.N4'-0" STANDARD SHOWERTO TOP OF BRACKET U.O.N2'-9" ACCESSIBLE TUBSHAMPOO, CONDITIONER, SHOWER GEL DISPENSERS - SURFACE MOUNTED GUESTROOMS
HD 16
TO OPERABLE PART3' - 10" MAX.NOTE: PROVIDE OVER HANDWASH SINK IN FOOD PREP
PROVIDE ADEQUATE CLEARANCE FROM FAUCET AND SINK
PAPER TOWEL /SOAP DISPENSERRECESSED
HD 17
FFL15" A.F.FLINE OF WALL
SHOWER FOOTRESTSURFACE MOUNTEDALL SHOWERS
HD 18
NOTE: MUST NOT PROJECT MORE THAN 4" INTO ACCESSIBLE ROUTE
3'6" - 3'-10" MAX.RECESSED WASTERECEPTACLEPOOL RESTROOMS
HD 19
REQ'D CLEAR
1' - 0"REQ'D CLEAR0' - 1 1/2"T.O GRIPPING SURFACE3' - 0"REQ'D CLEAR1' - 0"NOTE: MUST NOT PROJECT MORE THAN 4" INTO ACCESSIBLE ROUTE
TO TOP OF BRACKET U.O.N4' - 0" U.O.NTYP
0' - 5 1/2"
GRAB BAR (TUB)SURFACE MOUNTED
HD 20
LOTION AND HAND GEL DISPENSERSURFACE MOUNTED GUESTROOMS
HD 21
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216RESTROOMACCESSORY ANDMOUNTING DETAILS
A-426
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
Revision Schedule
Number Description Date
5
6.1
C.1
F
F
G
G
E
EC
A-432
5
8
A-432
1
3
24
A-433
1
1
A-302
8.1
9
A-503
1
A-432A
1
2
2
3
4
63
67
A-43315
13
14
406 SF
MEETING
ROOM
120
81 SF
MEETING
STORAGE
119
172 SF
WOMEN'SRESTROOM
115
171 SF
MEN'SRESTROOM
116
176 SF
ELEVATORLOBBY
117
64 SF
ELEV 2
113
68 SF
ELEV 1
111
2,670 SF
LOBBY
121
150 SF
VESTIBULE
122
A-433
A-7011
A-43312
9
10
11
A-437
1
A-7104
176 SF
GUESTSTORAGE
118
7
8
6
10
H
TYP
PA-101
PA-100
TYP
PA-105
TYP
PA-102
TYP
PA-102
TYP
PA-103 TYP
PA-104
TYP
PA-103
TYP
PA-104
TYP
PA-108
TYP
PA-107
TYP
PA-105
PA-304
TYP
PA-304
PA-302
PA-302
PA-302
PA-302
PA-306
PA-305
PA-300
PA-300
TYP
PA-301
TYP
PA-301
TYP
PA-106
PA-303
TYP
PA-106
PA-303 PA-111
PA-109
PA-307
PA-311
PA-309
TYP
PA-110
PA-302
17 SF
ICE/WATER
118A
WP-01
WP-01
WP-01
WP-01
D-117
D-123
D-124D-120
D-122A
PA-310
A-7101
PA-316
TYP
PA-318A
TYP
PA-318
TYP
OP-105
PA-317
2
A-301
2' - 2"3' - 2 3/4" 5' - 1 3/4"4' - 1 3/4"
W-BCW-D
1' - 4"17' - 4 1/2"4' - 10"5' - 3 1/2"3' - 8"CW-K
CW-D
CW-E CW-E
12' - 10"25' - 4"
CW-C
17' - 4 1/2"5' - 6 1/2"5' - 0"11' - 11 1/2"6' - 7 1/4"5' - 3 1/2"3' - 6 1/4"3' - 8 3/4"1' - 4 3/4"8' - 7 1/2"
1' - 2"
D-115
D-116
8' - 7"1' - 1 3/4"1' - 4 3/4"3' - 10"1' - 10 3/4"1' - 4 3/4"16' - 10"0' - 10"42' - 3 1/2"
0' - 3 3/4"
1' - 11 1/2"
5' - 6"
4' - 10 3/4"
8' - 7"
1
A-505
2' - 4 1/4"
K-99
K-505' - 2"9' - 4 1/4"<varies>
P2.3
XE1/2
P5.4
P5.1
P7
P1.1
P3.1
P3.3
CW-C
P2.2
XE1/2
XE1/2
XS4
P3.3
P1.2
P3.3
XS2XS2
P3.3
XE3
P3.1
1' - 9 1/4"8' - 7 1/2"
1' - 11"
A-702
3
A-7031
A-706
1
CW-N
CW-M
CW-A2 CW-A1CW-B
D-121
TYP
PA-319
A-704
2
A-704
3
A-7013
A-701
3
XS4
XS1
A-70411
P1.2
OP-301
K-84
K-85
K-89
K-56
K-55
K-55.1
K-29
K-61
K-75
K-75
K-30K-72
K-60
K-67
K-87
3' - 6"
PF-45
K-58
K-66 K-55.2
K-71
K-71
K-29
K-29.1
K-65
A-432A
4
5
7
8
8
A-705
5
8
7
6
13TYP.
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216ENLARGED PLAN -LOBBY, MEETINGROOM, RESTROOMS &STORAGE
A-431
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
0'2' 4'8'
SCALE: 1/4" = 1'-0"
1/4" = 1'-0" Reference: 1 / A-122
1ENLARGED LOBBY PLAN
FURNISHING SCHEDULE
PUBLIC AREA FURNISHINGS
PA-100 BENCH - DINING ROOM BANQUETTE
PA-101 CHAIR - BANQUETTE
PA-102 CHAIR - HIGH TOP BARSTOOL
PA-103 CHAIR - BARREL LOUNGE CHAIR
PA-104 CHAIR - LOUNGE
PA-105 CHAIR - COUNTER HEIGHT STOOL
PA-106 CHAIR - DINING TWO-TOP
PA-107 CHAIR - TABLE HEIGHT STOOL
PA-108 CHAIR - WORK TABLE STOOL
PA-109 SOFA - LOBBY SECTIONAL
PA-110 CHAIR - LOUNGE CHAIR
PA-111 BENCH - RECEPTION
PA-201 LAMP - LOBBY FLOOR LAMP
PA-300 TABLE - BANQUETTE
PA-301 TABLE - HIGH 4-TOP
PA-302 TABLE - ROUND TEA HEIGHT
PA-303 TABLE - DINING 2-TOP
PA-304 TABLE - WINDOW COUNTER
PA-305 TABLE - INDUCTION TABLE
PA-306 TABLE - COMMUNAL WORK TABLE
PA-307 TABLE - SOFA COFFEE TABLE
PA-309 TABLE - SIDE TABLE AT SOFA
PA-310 CASEWORK - COFFEE STATION
PA-311 CASEWORK - ENTERTAINMENTCONSOLE
PA-316 CASEWORK - PRINTER CABINET
PA-317 CASEWORK - MEETING CONSOLE
PA-318 MEETING ROOM TABLE - 6' LONG
PA-318A MEETING ROOM TABLE - 8' LONG
PA-319 RETAIL SHELVING
PA-502 ART - PUBLIC RESTROOM- WOMEN'S
PA-505 ART - 1ST FLOOR ELEVATOR LOBBY
PA-506 MIRROR - PUBLIC RESTROOM VANITY
PA-507 MIRROR - PUBLIC RESTROOM FULLHEIGHT
PA-803 FIRE EXTINGUISHER - K CLASS - 2.5GAL
HILTON SPECIFIED - OWNER FURNISHED
OF-700 CHAIR - LOUNGE CHAIR UNDERCANOPY
OF-705 TABLE - 17" D OUTDOOR SIDE TABLE
OWNER SPECIFIED - OWNER FURNISHED
OP-105 CHAIR - MEETING ROOM
OP-301 POOL TABLE
OP-703 LAUNDRY CART
OP-704 BIKE RACK
OP-705 FIRE EXTINGUISHER - ABC - 10 LBS
OP-706 FIRE EXTINGUISHER CABINET
KITCHEN EQUIPMENT
K-25 HAND SINK WITH SPLASH GUARDS
K-29 DOUBLE WAFFLE MAKER
K-29.1 BATTER DISPENSER
K-30 ELECTRIC JUICE DISPENSER
K-50 COMMERCIAL MICROWAVE
K-55 TAP WALL SPIGOT
K-55.1 TAP WALL SCREEN
K-55.2 4' WIDE DRIP PAN
K-56 FROST TOP - UNDER COUNTERTOP
K-58 BAKED GOODS DISPLAY
K-60 POP-UP 4-SLICE TOASTER
K-61 INDUCTION WARMER, DROP-IN
K-65 CEREAL DISPENSER
K-66 UNINSULATED BEVERAGE DISPENSER
K-67 COFFEE DISPENSING URN
K-71 CONDIMENT DISPENSER
K-72 NAPKIN DISPENSER
K-75 POS - CHECK-IN AND SUITE SHOP SALECOMPUTER
K-84 REFRIGERATOR - SELF-SERVE - 36"WIDE
K-85 REFRIGERATOR - SELF-SERVE - 47"WIDE
K-87 DESKTOP PRINTER - OFFICE/SHOP
K-89 SELF-SERVE FREEZER
K-99 ICE AND WATER DISPENSER
PLUMBING/MECHANICAL FIXTURES
PF-09 URINAL - WALL MOUNTED
PF-45 REFRIGERATED BOTTLE FILLER (CUPSPROVIDED)
KEYNOTES - ENLARGED
1 2-WAY AREA OF REFUGE COMMUNICATION WITHFRONT DESK.
2 CARD READER TO CALL SERVICE ELEVATOR
3 CALL BUTTONS WITH LOCK PER AHJREQUIREMENTS.
4 ELEVATOR INDICATORS
5 AFTER-HOURS ACCESS INTERCOM-CONNECTED TO FRONT DESK.
6 KITCHEN HOOD VENT
7 FRP PANELS ON WALLS TO BE WELDED AT ALLSEAMS. ENSURE ALL SEAMS BETWEENDIFFERING MATERIALS ARE BACKED ANDSEALED IN ORDER TO MAINTAIN A SANITARY,WASHABLE ENVIRONMENT.
8 CLEAR TEMPERED, PLATED MIRROR
9 FLAT SCREEN TV.
10 PROVIDE ARTICULATING ARM FORWALL-MOUNTED TV.
11 PROVIDE FULL SUITES OF DATA/VIDEO/POWERUNDER AND BEWTEEN THE WINDOWS ALONGALL WALLS.
12 MACHINES TO BE SET UP FOR CARD ACCESSONLY. COORDINATE POWER AND DATA WITHSUPPLIER.
13 USE CORNER GUARDS ON ALL SURFACESFINISHED WITH WALL COVERING IN PUBLICAREAS.
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
Revision Schedule
Number Description Date
EH
PT-12
CW-C
CW-B
D-121
CW-A2CW-A1
PL-01
7 8A-701
2
CT-12
PL-03
PT-12
WC-12
WC-12
WC-12
WC-12
K-55.1
K-55
K-29
K-30
K-89 K-85 K-84
K-50
PA-319
SS-01
CT-12
WC-12
CT-13
EH
WC-12PL-01WC-12
CW-K
D-120
PT-12WC-10
D-122A
CW-N
WP-01
78
WC-12
PT-12
A-7065
FGH
WC-12WC-12
PT-12
A-706
4
A-7045
A-7047
98WC-12
A-706
2
CW-E
CW-P
9 8WC-12
CW-E
CW-P
FGH
PT-12
PT-12
PT-12
CW-D
CW-D
CW-N
A-7041
PA-319CW-D
PF-45
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216INTERIOR ELEVATIONS -LOBBY
A-432
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
0'2' 4'8'
SCALE: 1/4" = 1'-0"
1/4" = 1'-0" Reference: 1 / A-431
1LOBBY NORTH ELEVATION OF EXTERIOR WALL
North Wall in Lobby (Room 121)
1/4" = 1'-0" Reference: 1 / A-407
2 LOBBY EAST ELEVATION TOWARDS GUEST CORRIDOR
East Wall in Lobby- Tap Wall and Suite Shop (Room 121)
1/4" = 1'-0" Reference: 1 / A-431
3LOBBY SOUTH ELEVATION TOWARDS INTERIOR
Breakfast Area and Seating in Lobby (Room 121)
1/4" = 1'-0" Reference: 1 / A-407
4 LOBBY WEST ELEVATION TOWARDS INTERIOR
Suite Shop and Breakfast Area in Lobby (Room 121)
FFL
FFL
FFL
1/4" = 1'-0" Reference: 1 / A-431
5LOBBY NORTH ELEVATION TOWARDS INTERIOR
1/4" = 1'-0" Reference: 1 / A-431
6LOBBY / VESTIBULE EAST ELEVATION
Reception Desk and Vestibule
FFL
1/4" = 1'-0" Reference: 1 / A-431
7 LOBBY / VESTIBULE WEST ELEVATION
Waiting Area and Vestibule
1/4" = 1'-0" Reference: 1 / A-431
8LOBBY SOUTH ELEVATION OF EXTERIOR WALL
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
Revision Schedule
Number Description Date
FGE KHJ
WC-10
WP-1
WC-12
OP-706
D-123
PL-11 PT-11
PA-310
RB-10
78
PT-12
WC-12
OP-301
WP-1WP-1
978
PUBLIC CORRIDOR BEYOND
RB-10RB-10RB-10
WC-12WC-12WC-12
1' - 0"A-510
11Typ13
A-5107
A-704
ART WALL
PA-500
FG EKHJ
A-7063
WC-10
RB-10
WC-12
CW-K
D-120
WC-12
WC-10
D-124D-128
PC-04
PT-12
WP-1PT-11PL-11PT-11PL-11
G
2
A-301
D-122A
CW-N
PC-04
9
CW-P
CW-E
WC-10 CT-10.1
PC-04
G
2
A-301
D-122
CW-M
PC-04 9 WC-10PC-04
CW-E
CW-P
CT-10.1
EQ EQ
3' - 10"5
ACT ACOUSTIC CEILING TILEASALUMINUM STOREFRONTCGCORNER GUARDCONC CONCRETE, UNFINISHEDCPCARPETCPTCARPET TILECSCONCRETE, FINISHEDGWBGYPSUM WALL BOARDFCFIBER CEMENTFRPFIBERGLASS-REINFORCEDPLASTICMR GWB MOISTURE-RESISTANT GYPSUM WALL BOARDPLPLASTIC LAMINATEPTPAINT/POWDER COATQTQUARRY TILERBRUBBER BASERESRESILIENT TILE FLOORSCSTAMPED CONCRETESFSPECIALTY FINISH (KNOCK DOWN)SS ENGINEERED SOLID SURFACESTSTONESTLSTAINLESS STEELSTRUC STRUCTURE ABOVEVCTVINYL COMPOSITE TILEWCVINYL WALL COVERINGWDWOOD-LOOK ALUMINUM SLATS AND BATTENSWPSCREEN WALL
NOTE: REFER TO FF&E PACKAGE AND SPECIFICATION BOOK FOR FURNITURE AND FINISH SPECIFICATIONS
FINISH LEGEND
FFL
FFL
1/4" = 1'-0" Reference: 1 / A-431
1LOBBY NORTH ELEVATION THROUGH CENTRAL CIRCULATION
1/4" = 1'-0" Reference: 1 / A-403
3LOBBY EAST ELEVATION TOWARDS INTERIOR
1/4" = 1'-0" Reference: 1 / A-403
6LOBBY WEST ELEVATION TOWARD PUBLIC CORRIDOR
FFL
1/4" = 1'-0" Reference: 1 / A-431
2LOBBY SOUTH ELEVATION THROUGH CENTRAL CIRCULATION
FFL
1/4" = 1'-0" Reference: 1 / A-407
4VESTIBULE NORTH ELEVATION
Room 122
1/4" = 1'-0" Reference: 1 / A-407
5 VESTIBULE EAST ELEVATION
Room 122
0'2' 4'8'
SCALE: 1/4" = 1'-0"
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216INTERIOR ELEVATIONS -LOBBY, VESTIBULE
A-432A
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
FURNISHING SCHEDULE
GUESTROOM FURNISHINGS
GR-201 SCONCE - NIGHTSTAND
GR-307 NIGHTSTAND - SMALL
GR-308 NIGHTSTAND - REGULAR
GR-319 CLOSET - EFFICIENCY SUITE
GR-325 VANITY - EFFICIENCY SUITE
GR-326 VANITY - STUDIO AND 1-BEDROOMSUITES
GR-506 MIRROR - GUESTROOM FULL LENGTH
GR-907 CLOCK/RADIO
GR-908 TELEPHONE - GUESTROOM
GR-ES BED - EFFICIENCY (GR-300, 303, 600)
PUBLIC AREA FURNISHINGS
PA-100 BENCH - DINING ROOM BANQUETTE
PA-101 CHAIR - BANQUETTE
PA-102 CHAIR - HIGH TOP BARSTOOL
PA-103 CHAIR - BARREL LOUNGE CHAIR
PA-104 CHAIR - LOUNGE
PA-105 CHAIR - COUNTER HEIGHT STOOL
PA-106 CHAIR - DINING TWO-TOP
PA-107 CHAIR - TABLE HEIGHT STOOL
PA-108 CHAIR - WORK TABLE STOOL
PA-109 SOFA - LOBBY SECTIONAL
PA-110 CHAIR - LOUNGE CHAIR
PA-111 BENCH - RECEPTION
PA-200 PENDANT LIGHT - RECEPTION
PA-201 LAMP - LOBBY FLOOR LAMP
PA-204 SCONCE - PUBLIC AREAS
PA-300 TABLE - BANQUETTE
PA-301 TABLE - HIGH 4-TOP
PA-302 TABLE - ROUND TEA HEIGHT
PA-303 TABLE - DINING 2-TOP
PA-304 TABLE - WINDOW COUNTER
PA-305 TABLE - INDUCTION TABLE
PA-306 TABLE - COMMUNAL WORK TABLE
PA-307 TABLE - SOFA COFFEE TABLE
PA-309 TABLE - SIDE TABLE AT SOFA
PA-310 CASEWORK - COFFEE STATION
PA-311 CASEWORK - ENTERTAINMENTCONSOLE
PA-316 CASEWORK - PRINTER CABINET
PA-317 CASEWORK - MEETING CONSOLE
PA-318 MEETING ROOM TABLE - 6' LONG
PA-318A MEETING ROOM TABLE - 8' LONG
PA-319 RETAIL SHELVING
PA-400A ROLLER SHADE - LOBBY - MANUAL,SHEER, CEILING MOUNT, 4' - 5" W
PA-400B ROLLER SHADE - LOBBY - MANUAL,SHEER, CEILING MOUNT, 4' - 1" W
PA-400D ROLLER SHADE - LOBBY - MANUAL,SHEER, CEILING MOUNT, 3' - 10.25" W
PA-401 ROLLER SHADE - PUBLIC/BOH -MANUAL, SHEER, WALL MOUNT, 5' W
PA-405 ROLLER SHADE - MEETING ROOMENTRY - MANUAL, SHEER, CEILINGMOUNT, 3' - 1.5" W
PA-500 ART - CENTRAL HUB BANQUETTE
PA-505 ART - 1ST FLOOR ELEVATOR LOBBY
PA-803 FIRE EXTINGUISHER - K CLASS - 2.5GAL
OWNER SPECIFIED - OWNER FURNISHED
OP-105 CHAIR - MEETING ROOM
OP-301 POOL TABLE
OP-704 BIKE RACK
OP-705 FIRE EXTINGUISHER - ABC - 10 LBS
OP-706 FIRE EXTINGUISHER CABINET
KITCHEN EQUIPMENT
K-01 WIRE SHELVING - 24"X60" WITH FEET
K-04 WIRE SHELVING - 24" X 60" WITHLOCKING CAGE AND CASTERS
K-05 BAR BACK COOLER
K-07 WALK IN REFRIGERATOR
K-10 WIRE SHELVING - 24" X 36" WITHCASTERS
K-13 FAUCET WITH WALL BRACKET
1/4" = 1'-0" Reference: 1 / A-101
7VESTIBULE SOUTH ELEVATION
Room 122
1/4" = 1'-0" Reference: 1 / A-407
8 VESTIBULE WEST ELEVATION
Room 122
FURNISHING SCHEDULE
K-15 WIRE SHELVING - 24" X 48" WITHCASTERS
K-16 3 COMPARTMENT SINK WITH WORKTABLE AND DRYING AREA
K-17 STAINLESS STEEL WALL SHELVES
K-18 FLOOR TROUGH - 48" X 12"
K-19 PRERINSE SPRING WITH WALLBRACKET AND FAUCET
K-20 DISPOSER
K-22 UNDERCOUNTER DISHWASHER
K-25 HAND SINK WITH SPLASH GUARDS
K-26 ICE MAKER - CUBELET
K-27 ICE STORAGE BIN
K-28 FLOOR TROUGH - 24" X 12"
K-29 DOUBLE WAFFLE MAKER
K-29.1 BATTER DISPENSER
K-30 ELECTRIC JUICE DISPENSER
K-31 REFRIGERATED DRAWERS ANDWORKTOP
K-32 2-CARAFE COMMERCIAL COFFEEMAKER
K-33 STAINLESS STEEL WALL SHELVES
K-36 STAINLESS STEEL WALL SHELVES
K-39 WORK TABLE W/ PREP SINKS
K-40 STAINLESS STEEL WALL SHELVES
K-41 REACH IN FREEZER- 3 DOOR
K-42 ELECTRIC CONVECTION OVEN - FULLSIZE SHEET PAN
K-43 ELECTRIC PROOFER AND HOLDINGCABINET - FULL SIZE SHEET PAN
K-45 WORK TABLE WITH PREP SINK
K-47 PASTA COOKER - 2.5 GAL
K-49 INDUCTION RANGE, COUNTERTOP
K-50 COMMERCIAL MICROWAVE
K-51 CLASS 1 KITCHEN HOOD
K-55 TAP WALL SPIGOT
K-55.1 TAP WALL SCREEN
K-55.2 4' WIDE DRIP PAN
K-56 FROST TOP - UNDER COUNTERTOP
K-58 BAKED GOODS DISPLAY
K-60 POP-UP 4-SLICE TOASTER
K-61 INDUCTION WARMER, DROP-IN
K-65 CEREAL DISPENSER
K-66 UNINSULATED BEVERAGE DISPENSER
K-67 COFFEE DISPENSING URN
K-71 CONDIMENT DISPENSER
K-72 NAPKIN DISPENSER
K-75 POS - CHECK-IN AND SUITE SHOP SALECOMPUTER
K-75A POUR MY BEER CONTROL CENTER
K-84 REFRIGERATOR - SELF-SERVE - 36"WIDE
K-85 REFRIGERATOR - SELF-SERVE - 47"WIDE
K-87 DESKTOP PRINTER - OFFICE/SHOP
K-89 SELF-SERVE FREEZER
PLUMBING/MECHANICAL FIXTURES
PF-01 TOILET - GUESTROOM
PF-03 SHOWER BASE - 60" X 36" WITH LINEARDRAIN
PF-07 LAVATORY - UNDERMOUNT, 20" X 14"
PF-11 SHOWER HEAD - 2 IN 1
PF-13 SHOWER/TUB VALVE & CONTROL
PF-15 FAUCET - LAVATORY
PF-45 REFRIGERATED BOTTLE FILLER (CUPSPROVIDED)
TOILET ACCESSORIES
HD-01 DUAL TOILET PAPER HOLDER
HD-04 WALL-MOUNTED ROBE HOOK
HD-05.2 SLIDING SHOWER DOOR
HD-08 18" GRAB BAR
HD-18.1 SOAP SHELF
HD-21 BULK AMENITY DISPENSER ATLAVATORIES
KEYNOTES - ENLARGED
1 2-WAY AREA OF REFUGE COMMUNICATION WITHFRONT DESK.
2 CARD READER TO CALL SERVICE ELEVATOR
3 CALL BUTTONS WITH LOCK PER AHJREQUIREMENTS.
4 ELEVATOR INDICATORS
5 AFTER-HOURS ACCESS INTERCOM-CONNECTED TO FRONT DESK.
6 KITCHEN HOOD VENT
7 FRP PANELS ON WALLS TO BE WELDED AT ALLSEAMS. ENSURE ALL SEAMS BETWEENDIFFERING MATERIALS ARE BACKED ANDSEALED IN ORDER TO MAINTAIN A SANITARY,WASHABLE ENVIRONMENT.
8 CLEAR TEMPERED, PLATED MIRROR
9 FLAT SCREEN TV.
10 PROVIDE ARTICULATING ARM FORWALL-MOUNTED TV.
11 PROVIDE FULL SUITES OF DATA/VIDEO/POWERUNDER AND BEWTEEN THE WINDOWS ALONGALL WALLS.
12 MACHINES TO BE SET UP FOR CARD ACCESSONLY. COORDINATE POWER AND DATA WITHSUPPLIER.
13 USE CORNER GUARDS ON ALL SURFACESFINISHED WITH WALL COVERING IN PUBLICAREAS.
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
Revision Schedule
Number Description Date
E
D-120
CW-K
WC-10WC-10
PA-317
PC-04
11' - 0"910
WC-10WC-10
E
PT-12
RB-10
W-B W-B
PA-401 PA-401
PA-318APA-318
RB-10
D-119
WC-10
PL-11 PT-11
WC-11WC-12
RB-10
K-998' - 0"8' - 0"10' - 0"PL-04PL-03PL-01PL-04PL-01
C.1A-704
4
WC-12WC-12 WC-12
WC-11
RB-10 PL-11 PT-11
D-115
K-99
PL-01
PL-01
WC-12 WC-12
RB-10
WC-11
K-99
C.1
OPEN TO CORRIDOR BEYONDD-116
WC-12
PL-11PT-11CT-10.1
WC-12A-702
5
D-117
PT-11
RB-10
PC-04
OPEN TO LOBBY BEYOND
7
WC-11
RB-10
PA-505
3' - 6"6' - 0"ART
EQEQ
WALL
OPEN TO CORRIDOR
7
RB-10
WC-11
ELEVATOR DOOR ELEVATOR DOOR
3' - 10"EQ EQ 2
7' - 0"6' - 0"PA-204
PA-2044
3 3' - 10"C.1
PT-03
RB-10
PT-03
RB-10
C.1
PT-03
PT-03
RB-10RB-10
PT-03
PL-11
PT-11
RB-10
D-119
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216INTERIOR ELEVATIONS -MTG. ROOM & STO,ELEVATOR LOBBY,GUEST STO.
A-433
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
0'2' 4'8'
SCALE: 1/4" = 1'-0"
1/4" = 1'-0" Reference: 1 / A-431
1MEETING ROOM NORTH ELEVATION
Room 120
1/4" = 1'-0" Reference: 1 / A-431
2MEETING ROOM EAST ELEVATION
Room 120
1/4" = 1'-0" Reference: 1 / A-431
3MEETING ROOM SOUTH ELEVATION
Room 120
1/4" = 1'-0" Reference: 1 / A-431
4 MEETING ROOM WEST ELEVATION
Room 120
1/4" = 1'-0" Reference: 1 / A-431
10GUEST STORAGE EAST ELEVATION
Rooms 118 & 118A
1/4" = 1'-0" Reference: 1 / A-431
11GUEST STORAGE SOUTH ELEVATION
Rooms 118 & 118A
1/4" = 1'-0" Reference: 1 / A-431
12 GUEST STORAGE WEST ELEVATION
Rooms 118 & 118A 1/4" = 1'-0" Reference: 1 / A-431
9GUEST STORAGE NORTH ELEV.
Rooms 118 & 118A
FFL
FFL
FFL
1/4" = 1'-0" Reference: 1 / A-431
13ELEVATOR LOBBY, 1ST FLR, N.ELEV.
Room 117
1/4" = 1'-0" Reference: 1 / A-403
14ELEVATOR LOBBY, 1ST FLR, EAST ELEV.
Room 117
1/4" = 1'-0" Reference: 1 / A-403
15 ELEVATOR LOBBY, 1ST FLR, WEST ELEV.
Room 117
FFL
1/4" = 1'-0" Reference: 1 / A-101
7MTG RM STORAGE SOUTH ELEVATION
Room 119
1/4" = 1'-0" Reference: 1 / A-101
8 MTG RM STORAGE WEST ELEVATION
Room 119
1/4" = 1'-0" Reference: 1 / A-101
5MTG RM STORAGE NORTH ELEVATION
Room 119
1/4" = 1'-0" Reference: 1 / A-101
6MTG RM STORAGE EAST ELEVATION
Room 119
FURNISHING SCHEDULE
PUBLIC AREA FURNISHINGS
PA-100 BENCH - DINING ROOM BANQUETTE
PA-101 CHAIR - BANQUETTE
PA-105 CHAIR - COUNTER HEIGHT STOOL
PA-106 CHAIR - DINING TWO-TOP
PA-203 PENDANT LIGHT - PUBLIC RESTROOM
PA-204 SCONCE - PUBLIC AREAS
PA-300 TABLE - BANQUETTE
PA-303 TABLE - DINING 2-TOP
PA-304 TABLE - WINDOW COUNTER
PA-311 CASEWORK - ENTERTAINMENTCONSOLE
PA-316 CASEWORK - PRINTER CABINET
PA-317 CASEWORK - MEETING CONSOLE
PA-318 MEETING ROOM TABLE - 6' LONG
PA-318A MEETING ROOM TABLE - 8' LONG
PA-400A ROLLER SHADE - LOBBY - MANUAL,SHEER, CEILING MOUNT, 4' - 5" W
PA-401 ROLLER SHADE - PUBLIC/BOH -MANUAL, SHEER, WALL MOUNT, 5' W
PA-405 ROLLER SHADE - MEETING ROOMENTRY - MANUAL, SHEER, CEILINGMOUNT, 3' - 1.5" W
PA-500 ART - CENTRAL HUB BANQUETTE
PA-502 ART - PUBLIC RESTROOM- WOMEN'S
PA-505 ART - 1ST FLOOR ELEVATOR LOBBY
PA-507 MIRROR - PUBLIC RESTROOM FULLHEIGHT
OWNER SPECIFIED - OWNER FURNISHED
OP-105 CHAIR - MEETING ROOM
OP-705 FIRE EXTINGUISHER - ABC - 10 LBS
OP-706 FIRE EXTINGUISHER CABINET
KITCHEN EQUIPMENT
K-99 ICE AND WATER DISPENSER
TOILET ACCESSORIES
HD-13 AUTOMATIC PAPER TOWEL DISPENSER
KEYNOTES - ENLARGED
1 2-WAY AREA OF REFUGE COMMUNICATION WITHFRONT DESK.
2 CARD READER TO CALL SERVICE ELEVATOR
3 CALL BUTTONS WITH LOCK PER AHJREQUIREMENTS.
4 ELEVATOR INDICATORS
5 AFTER-HOURS ACCESS INTERCOM-CONNECTED TO FRONT DESK.
6 KITCHEN HOOD VENT
7 FRP PANELS ON WALLS TO BE WELDED AT ALLSEAMS. ENSURE ALL SEAMS BETWEENDIFFERING MATERIALS ARE BACKED ANDSEALED IN ORDER TO MAINTAIN A SANITARY,WASHABLE ENVIRONMENT.
8 CLEAR TEMPERED, PLATED MIRROR
9 FLAT SCREEN TV.
10 PROVIDE ARTICULATING ARM FORWALL-MOUNTED TV.
11 PROVIDE FULL SUITES OF DATA/VIDEO/POWERUNDER AND BEWTEEN THE WINDOWS ALONGALL WALLS.
12 MACHINES TO BE SET UP FOR CARD ACCESSONLY. COORDINATE POWER AND DATA WITHSUPPLIER.
13 USE CORNER GUARDS ON ALL SURFACESFINISHED WITH WALL COVERING IN PUBLICAREAS.
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
Revision Schedule
Number Description Date
594 SF
FOOD PREP
123
46 SF
COURTYARDSTORAGE
141
135 SF
ELECTRICAL
128
233 SF
OPEN OFFICE
124
104 SF
OWNER'SOFFICE
127
95 SF
GM OFFICE
125
106 SF
SALES OFFICE
126
A-434A
1
4
56
A-443
9
11
1012
A-434
14
16
1517
A-434
10
12
1113
A-434
1
3
24
A-4349
6
7
8
A-434A
9
7
108
28' - 8 1/2"
162 SF
PUBLICCORRIDOR
121A
D-139
CW-J
9
K
7
8
6
10
H
J
D-124
D-125D-126
D-127
D-128
P1.2
P1.2
P1.2
P1.2
P3.3
TRASH/BUSSING
20' - 11 1/4"D-1233' - 10 3/4"1' - 10 3/4"2' - 9"13' - 1 3/4"9' - 11 1/2"1' - 11 3/4"3' - 3"6' - 0"1' - 9 3/4"
2' - 2 1/2"
8' - 1 1/4"
1' - 9 3/4"
3' - 3"5' - 9 1/2"1' - 4 1/4"8' - 7 1/2"7' - 2 3/4"3' - 2 1/2"10' - 7 1/2"4' - 3 1/2"0' - 11 1/2"5' - 2"2' - 2 3/4"3' - 8 1/2"10' - 8 3/4"1' - 9"W-BW-B
W-B
D-141
A-703
1
K-05
K-56
K-07
K-04
K-15
K-15
K-01
K-01K-01
K-01
K-02
K-84
K-85
K-89
K-50
K-55
K-55.1
K-11
K-10K-50
K-14
K-25
K-25
K-18
K-28
K-26K-27
K-02
K-05
K-42K-45
K-43K-49K-47
K-22
K-22
K-16
K-41
K-32K-49
K-29
K-29
K-30
A-434A32
P3.3
XD1
XE3
P3.3
P8
P8PA-803
QT-01
CT-10
CPT-14CS-01
K-55.2
K-31
K-39
K-29.1
K-75A
J
2' - 4"OP-705
D-124
PT-03PT-03PT-03PF-11PF-11
RB-10RB-109' - 0"RB-10
PT-03
J
D-127 D-126 D-125
PF-03 PF-03 PF-03PF-03 PF-03 PF-03 RB-10RB-10
PT-03 PT-03 PT-03PT-03PT-03
RB-10 RB-10 RB-103' - 0"1' - 8"4' - 8"OP-705
K-75A
K-87
HD-04
6' - 9"
2' - 6"
OP-103OP-102
OP-101
PF-03PF-03
RB-10
PT-03PT-03
D-125
PA-401
OP-101
OP-102OP-102
OP-103
PT-03
RB-10 RB-10
PT-03PA-401
OP-102
OP-101
OP-103
W-B
OP-103
OP-102OP-102
PA-401
PT-03PT-03
RB-10
J
D-126
OP-103
OP-102
OP-101
PT-03
RB-109' - 0"PF-03PF-03
9
PT-03
RB-10
J
PA-401
OP-101
OP-102 OP-103RB-10
PT-03 PT-03
W-B
9
TYP
OP-102OP-103
OP-101
RB-10
PT-03PA-401
PT-03
RB-10
D-127
OP-103OP-101OP-102
PT-03
PF-03PF-03RB-10
9PT-03 PT-03
RB-10 RB-10
PA-401
OP-101
OP-103
OP-102
W-B
OP-102OP-103OP-101
PA-401 PT-03
RB-10
9 PT-03
RB-10 9' - 0"ACTACOUSTIC CEILING TILEASALUMINUM STOREFRONTCGCORNER GUARDCONC CONCRETE, UNFINISHEDCPCARPETCPTCARPET TILECSCONCRETE, FINISHEDGWBGYPSUM WALL BOARDFCFIBER CEMENTFRPFIBERGLASS-REINFORCEDPLASTICMR GWB MOISTURE-RESISTANT GWBPFPRE-FINISHED DOORPLPLASTIC LAMINATEPTPAINT/POWDER COATQTQUARRY TILERBRUBBER BASERESRESILIENT TILE FLOORSCSTAMPED CONCRETESFSPECIALTY FINISH (KNOCK DOWN)SSENGINEERED SOLID SURFACESTSTONESTLSTAINLESS STEELSTRUC STRUCTURE ABOVEVCTVINYL COMPOSITE TILEWCVINYL WALL COVERINGWDWOOD-LOOK ALUMINUM SLATS AND BATTENSWPSCREEN WALL
NOTE: REFER TO FF&E PACKAGE AND SPECIFICATION BOOK FOR FURNITURE AND FINISH SPECIFICATIONS
FINISH LEGEND
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216ENLARGED PLAN &INTERIOR ELEVATIONS -OFFICES AND FOODPREP
A-434
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
0'2' 4'8'
SCALE: 1/4" = 1'-0"
1/4" = 1'-0" Reference: 1 / A-122
5OFFICES AND FOOD PREP PLAN
1/4" = 1'-0" Reference: 1 / A-431
1OPEN OFFICE NORTH ELEVATION
Room 124
1/4" = 1'-0" Reference: 5 / A-434
2OPEN OFFICE EAST EL.
Room 124
1/4" = 1'-0" Reference: 1 / A-431
3 OPEN OFFICE SOUTH ELEVATION
Room 124
1/4" = 1'-0" Reference: 5 / A-434
4 OPEN OFFICE WEST ELEVATION
Room 124
1/4" = 1'-0" Reference: 2 / A-408
6GM OFFICE N. ELEV.
Room 125
1/4" = 1'-0" Reference: 2 / A-408
7GM OFFICE E. ELEV.
Room 125
1/4" = 1'-0" Reference: 2 / A-408
8 GM OFFICE S. ELEV.
Room 125
1/4" = 1'-0" Reference: 5 / A-434
9 GM OFFICE W. ELEV.
Room 125
1/4" = 1'-0" Reference: 5 / A-434
10SALES OFFICE N. ELEV.
Room 126
1/4" = 1'-0" Reference: 5 / A-434
11SALES OFFICE E. ELEV.
Room 126
1/4" = 1'-0" Reference: 5 / A-434
12 SALES OFFICE S. ELEV.
Room 126
1/4" = 1'-0" Reference: 5 / A-434
13 SALES OFFICE W. ELEV.
Room 126
1/4" = 1'-0" Reference: 5 / A-434
14OWNER'S OFFICE N. ELEV.
Room 127
1/4" = 1'-0" Reference: 5 / A-434
15OWNER'S OFFICE E. ELEV.
Room 127
1/4" = 1'-0" Reference: 5 / A-434
16 OWNER'S OFFICE S. ELEV.
Room 127
1/4" = 1'-0" Reference: 5 / A-434
17 OWNER'S OFFICE W. ELEV.
Room 127
FURNISHING SCHEDULE
GUESTROOM FURNISHINGS
GR-201 SCONCE - NIGHTSTAND
GR-308 NIGHTSTAND - REGULAR
GR-KS BED - KING (GR-301, 303, 600)
PUBLIC AREA FURNISHINGS
PA-107 CHAIR - TABLE HEIGHT STOOL
PA-319 RETAIL SHELVING
PA-401 ROLLER SHADE - PUBLIC/BOH - MANUAL, SHEER,WALL MOUNT, 5' W
PA-803 FIRE EXTINGUISHER - K CLASS - 2.5 GAL
HILTON SPECIFIED - OWNER FURNISHED
OF-700 CHAIR - LOUNGE CHAIR UNDER CANOPY
OWNER SPECIFIED - OWNER FURNISHED
OP-101 CHAIR - OFFICE
OP-102 CHAIR - GUEST
OP-103 OFFICE DESK
OP-704 BIKE RACK
OP-705 FIRE EXTINGUISHER - ABC - 10 LBS
OP-706 FIRE EXTINGUISHER CABINET
KITCHEN EQUIPMENT
K-01 WIRE SHELVING - 24"X60" WITH FEET
K-02 KEG COOLER POWER PACK
K-04 WIRE SHELVING - 24" X 60" WITH LOCKING CAGEAND CASTERS
K-05 BAR BACK COOLER
K-07 WALK IN REFRIGERATOR
K-10 WIRE SHELVING - 24" X 36" WITH CASTERS
K-11 WIRE SHELVING - 24" X 30" WITH CASTERS
K-13 FAUCET WITH WALL BRACKET
K-14 MOP SINK CABINET
K-15 WIRE SHELVING - 24" X 48" WITH CASTERS
K-16 3 COMPARTMENT SINK WITH WORK TABLE ANDDRYING AREA
K-18 FLOOR TROUGH - 48" X 12"
K-19 PRERINSE SPRING WITH WALL BRACKET ANDFAUCET
K-20 DISPOSER
K-22 UNDERCOUNTER DISHWASHER
K-25 HAND SINK WITH SPLASH GUARDS
K-26 ICE MAKER - CUBELET
K-27 ICE STORAGE BIN
K-28 FLOOR TROUGH - 24" X 12"
K-29 DOUBLE WAFFLE MAKER
K-29.1 BATTER DISPENSER
K-30 ELECTRIC JUICE DISPENSER
K-31 REFRIGERATED DRAWERS AND WORKTOP
K-32 2-CARAFE COMMERCIAL COFFEE MAKER
K-39 WORK TABLE W/ PREP SINKS
K-41 REACH IN FREEZER- 3 DOOR
K-42 ELECTRIC CONVECTION OVEN - FULL SIZE SHEETPAN
K-43 ELECTRIC PROOFER AND HOLDING CABINET -FULL SIZE SHEET PAN
K-45 WORK TABLE WITH PREP SINK
K-47 PASTA COOKER - 2.5 GAL
K-49 INDUCTION RANGE, COUNTERTOP
K-50 COMMERCIAL MICROWAVE
K-55 TAP WALL SPIGOT
K-55.1 TAP WALL SCREEN
K-55.2 4' WIDE DRIP PAN
K-56 FROST TOP - UNDER COUNTERTOP
K-71 CONDIMENT DISPENSER
K-75A POUR MY BEER CONTROL CENTER
K-84 REFRIGERATOR - SELF-SERVE - 36" WIDE
K-85 REFRIGERATOR - SELF-SERVE - 47" WIDE
K-87 DESKTOP PRINTER - OFFICE/SHOP
K-89 SELF-SERVE FREEZER
TOILET ACCESSORIES
HD-04 WALL-MOUNTED ROBE HOOK
HD-18 FOOT LEDGE FOR SHOWER
HD-18.1 SOAP SHELF
KEYNOTES - ENLARGED
1 2-WAY AREA OF REFUGE COMMUNICATION WITHFRONT DESK.
2 CARD READER TO CALL SERVICE ELEVATOR
3 CALL BUTTONS WITH LOCK PER AHJREQUIREMENTS.
4 ELEVATOR INDICATORS
5 AFTER-HOURS ACCESS INTERCOM- CONNECTEDTO FRONT DESK.
6 KITCHEN HOOD VENT. GC TO SUPPLY ANDINSTALL HOOD, MAU-01 AND EF-03 (SEEMECHANICAL).
7 FRP PANELS ON WALLS TO BE SEALED AT ALLSEAMS. ENSURE ALL SEAMS BETWEENDIFFERING MATERIALS ARE BACKED ANDSEALED IN ORDER TO MAINTAIN A SANITARY,WASHABLE ENVIRONMENT.
8 CLEAR TEMPERED, PLATED MIRROR
9 FLAT SCREEN TV.
10 PROVIDE ARTICULATING ARM FORWALL-MOUNTED TV.
11 PROVIDE FULL SUITES OF DATA/VIDEO/POWERUNDER AND BEWTEEN THE WINDOWS ALONGALL WALLS.
12 MACHINES TO BE SET UP FOR CARD ACCESSONLY. COORDINATE POWER AND DATA WITHSUPPLIER.
13 USE CORNER GUARDS ON ALL SURFACESFINISHED WITH WALL COVERING IN PUBLICAREAS.
14 BOX IN AROUND TOP OF WALK-INREFRIGERATOR
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
2 2
2
2
2
2
2
2
REVISION SCHEDULE
# DESCRIPTION DATE
2 ADDENDUM 2 6/21/2024
KJ
K-07
K-25
K-22
K-16
K-14
K-41
K-15
QT-01.1
K-11
FRP-01FRP-01FRP-01FRP-01P1.214
K-26
K-25
K-32
K-04
K-15K-15
K-07
K-51
FRP-01FRP-01
QT-01.1
PA-803
K-31K-0211' - 0"0' - 8 3/4"P1.2
146J
K-27
K-26
K-50
K-25
K-10
K-41K-42
K-51
K-45
K-43
K-47
K-49
K-32
D-123
K-16
K-22
FRP-01
QT-01.1PA-803
K-31
PF-11
PF-11
11' - 0"6
K-41
K-05
K-02
FRP-01
QT-01.1PA-803 11' - 0"K-33
K-33
7TYP.
J
14' - 8 3/4"PT-11
RB-10
D-141
PC-B
PC-B
66
RB-10
PT-11
3' - 2 3/4"
6
PT-11
RB-10
6 6
RB-10
PT-11
K-51
K-26
K-27
K-41
K-25
QT-01.1
FRP-01 FRP-01
QT-01.1
K-39
K-17 K-17
K-40
11' - 0"K-14K-11
K-16
K-22K-22
K-10
FRP-01
QT-01.1
K-20
K-13
K-19
K-17K-17
K-36K-40
ACT ACOUSTIC CEILING TILEASALUMINUM STOREFRONTCGCORNER GUARDCONC CONCRETE, UNFINISHEDCPCARPETCPTCARPET TILECSCONCRETE, FINISHEDGWBGYPSUM WALL BOARDFCFIBER CEMENTFRPFIBERGLASS-REINFORCEDPLASTICMR GWB MOISTURE-RESISTANT GWBPFPRE-FINISHED DOORPLPLASTIC LAMINATEPTPAINT/POWDER COATQTQUARRY TILERBRUBBER BASERESRESILIENT TILE FLOORSCSTAMPED CONCRETESFSPECIALTY FINISH (KNOCK DOWN)SS ENGINEERED SOLID SURFACESTSTONESTLSTAINLESS STEELSTRUC STRUCTURE ABOVEVCTVINYL COMPOSITE TILEWCVINYL WALL COVERINGWDWOOD-LOOK ALUMINUM SLATS AND BATTENSWPSCREEN WALL
NOTE: REFER TO FF&E PACKAGE AND SPECIFICATION BOOK FOR FURNITURE AND FINISH SPECIFICATIONS
FINISH LEGEND
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216INTERIOR ELEVATIONS -FOOD PREP
A-434A
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
0'2' 4'8'
SCALE: 1/4" = 1'-0"
FFL
1/4" = 1'-0" Reference: 5 / A-434
1FOOD PREP NORTH ELEVATION
Room 123
1/4" = 1'-0" Reference: 5 / A-434
5FOOD PREP EAST ELEVATION B
Room 123
1/4" = 1'-0" Reference: 5 / A-434
4FOOD PREP SOUTH ELEVATION
Room 123
1/4" = 1'-0" Reference: 5 / A-434
6 FOOD PREP WEST ELEVATION B
Room 123
FFL
1/4" = 1'-0" Reference: 1 / A-403
7COURTYARD STO. N. ELEV.
Room 141
1/4" = 1'-0" Reference: 1 / A-403
8CTYD STO. E. ELEV.
Room 141
1/4" = 1'-0" Reference: 1 / A-403
9COURTYARD STO. S. ELEV.
Room 141
1/4" = 1'-0" Reference: 1 / A-403
10 CTYD STO. W. ELEV.
Room 141
1/4" = 1'-0" Reference: 5 / A-434
3 FOOD PREP WEST ELEVATION A
Room 123
1/4" = 1'-0" Reference: 5 / A-434
2FOOD PREP EAST ELEVATION A
Room 123
FFL
FURNISHING SCHEDULE
GUESTROOM FURNISHINGS
GR-307 NIGHTSTAND - SMALL
GR-308 NIGHTSTAND - REGULAR
GR-319 CLOSET - EFFICIENCY SUITE
GR-325 VANITY - EFFICIENCY SUITE
GR-501 ART- EFFICIENCY SUITE BED
GR-506 MIRROR - LIGHTED BATHROOM VANITY
PUBLIC AREA FURNISHINGS
PA-803 FIRE EXTINGUISHER - K CLASS - 2.5 GAL
KITCHEN EQUIPMENT
K-01 WIRE SHELVING - 24"X60" WITH FEET
K-02 KEG COOLER POWER PACK
K-04 WIRE SHELVING - 24" X 60" WITH LOCKING CAGEAND CASTERS
K-05 BAR BACK COOLER
K-07 WALK IN REFRIGERATOR
K-10 WIRE SHELVING - 24" X 36" WITH CASTERS
K-11 WIRE SHELVING - 24" X 30" WITH CASTERS
K-13 FAUCET WITH WALL BRACKET
K-14 MOP SINK CABINET
K-15 WIRE SHELVING - 24" X 48" WITH CASTERS
K-16 3 COMPARTMENT SINK WITH WORK TABLE ANDDRYING AREA
K-17 STAINLESS STEEL WALL SHELVES
K-18 FLOOR TROUGH - 48" X 12"
K-19 PRERINSE SPRING WITH WALL BRACKET ANDFAUCET
K-20 DISPOSER
K-22 UNDERCOUNTER DISHWASHER
K-25 HAND SINK WITH SPLASH GUARDS
K-26 ICE MAKER - CUBELET
K-27 ICE STORAGE BIN
K-28 FLOOR TROUGH - 24" X 12"
K-31 REFRIGERATED DRAWERS AND WORKTOP
K-32 2-CARAFE COMMERCIAL COFFEE MAKER
K-33 STAINLESS STEEL WALL SHELVES
K-36 STAINLESS STEEL WALL SHELVES
K-39 WORK TABLE W/ PREP SINKS
K-40 STAINLESS STEEL WALL SHELVES
K-41 REACH IN FREEZER- 3 DOOR
K-42 ELECTRIC CONVECTION OVEN - FULL SIZE SHEETPAN
K-43 ELECTRIC PROOFER AND HOLDING CABINET -FULL SIZE SHEET PAN
K-45 WORK TABLE WITH PREP SINK
K-47 PASTA COOKER - 2.5 GAL
K-49 INDUCTION RANGE, COUNTERTOP
K-50 COMMERCIAL MICROWAVE
K-51 CLASS 1 KITCHEN HOOD
PLUMBING/MECHANICAL FIXTURES
PF-01 TOILET - GUESTROOM
PF-07 LAVATORY - UNDERMOUNT, 20" X 14"
PF-15 FAUCET - LAVATORY
TOILET ACCESSORIES
HD-04 WALL-MOUNTED ROBE HOOK
HD-21 BULK AMENITY DISPENSER AT LAVATORIES
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
REVISION SCHEDULE
# DESCRIPTION DATE
2 ADDENDUM 2 6/21/2024
KEYNOTES - ENLARGED
1 2-WAY AREA OF REFUGE COMMUNICATION WITH FRONTDESK.
2 CARD READER TO CALL SERVICE ELEVATOR
3 CALL BUTTONS WITH LOCK PER AHJ REQUIREMENTS.
4 ELEVATOR INDICATORS
5 AFTER-HOURS ACCESS INTERCOM- CONNECTED TO FRONTDESK.
6 KITCHEN HOOD VENT. GC TO SUPPLY AND INSTALL HOOD,MAU-01 AND EF-03 (SEE MECHANICAL).
7 FRP PANELS ON WALLS TO BE SEALED AT ALL SEAMS.ENSURE ALL SEAMS BETWEEN DIFFERING MATERIALS AREBACKED AND SEALED IN ORDER TO MAINTAIN A SANITARY,WASHABLE ENVIRONMENT.
8 CLEAR TEMPERED, PLATED MIRROR
9 FLAT SCREEN TV.
10 PROVIDE ARTICULATING ARM FOR WALL-MOUNTED TV.
11 PROVIDE FULL SUITES OF DATA/VIDEO/POWER UNDER ANDBEWTEEN THE WINDOWS ALONG ALL WALLS.
12 MACHINES TO BE SET UP FOR CARD ACCESS ONLY.COORDINATE POWER AND DATA WITH SUPPLIER.
13 USE CORNER GUARDS ON ALL SURFACES FINISHED WITHWALL COVERING IN PUBLIC AREAS.
14 BOX IN AROUND TOP OF WALK-IN REFRIGERATOR
2
2
2
DDDDWWWW56.1
B
28' - 10 1/2"10' - 8 3/4"26' - 7 1/4"19' - 1 1/4"7' - 1"4' - 9 3/4"6' - 0 3/4"9' - 6 3/4"12' - 6 1/2"16' - 4 1/2"6' - 11 1/4"12' - 6"5' - 0"
801 SF
FITNESS
114
257 SF
LAUNDRYLOUNGE
112
50 SF
EMP RR ADA
110A
30 SF
EMP RR
110B
432 SF
EMPLOYEEROOM
110
A-4356
A-43513
A-4358
10
11
12
1
2
5
3
4
7
361 SF
WATERHEATER & FIRE
108
A-436
9
A-4434
1
2
3
Fire Sprinkler Riser8.1 94
A
14' - 9"14' - 4"25' - 2"0' - 9"10' - 8 1/4"
786
D-108A
D-108
D-110D-112D-114
9' - 10 1/4"9' - 7 1/4"5' - 5 1/4"
5' - 4 1/4"
3' - 9"4' - 4"2' - 0"3' - 2 3/4"0' - 9 1/4"6' - 7"5' - 8"W-AW-BW-B6' - 11 1/2"W-BW-B W-B
0' - 9 1/4"6' - 2"6' - 1 1/2"3' - 9 1/4"
D-110B
D-110A
4' - 0 1/4"7' - 6"7' - 7"W-B
W-B
W-B
A-7035
A-705
2
6
WC-14 WC-14
RB-11
WC-14
RB-10
6
PT-14
W-A
RB-10
PA-403
TYP
PA-113
TYP
PA-312
WC-14WC-14
RB-11
9 10
8.18
WC-13
CW-K
D-114
RB-11RB-11
PC-04
PA-114
PA-401
0' - 4"1' - 2 1/4"1' - 6"5' - 0"
8
4' - 0"4' - 0"4' - 0"
12' - 0"
B
PT-14
PT-14
RB-11
W-BW-BW-B
RB-11
PA-401PA-401PA-401PA-401
EQEQ
4' - 0"0' - 6"8' - 0"8
11' - 6"10' - 0"11TYP.
8.18PT-14PT-14
RB-11RB-11
W-BW-BW-BW-B
PA-401PA-401PA-401PA-401PA-401
11TYP.
B
RB-11RB-11
2' - 10 3/4"5' - 0"
WC-13
WC-13WC-13
5' - 0"2' - 7"7' - 0"PA-401
PA-114PF-45
WC-13
9
A-703
8
A-703
7
A-703
Typ
3' - 10"4' - 2"0' - 5"0' - 5"
PA-508
WC-13
910
CT-10.1
WC-14
PF-36 PF-36 PF-36 PF-36
2' - 7 1/2"2' - 10"3' - 6"
0' - 2 1/2" TYP.
4' - 10 1/2"4' - 10 1/2"
10' - 4 1/2"
PL-01
12 12 12 12
EQ EQ
5' - 6"PA-503
7
A-705
3
A-705
6.1PT-14
W-B
CT-10.1
PA-401
PF-36
PF-35
WC-14 WC-14
CT-10.1
PF-35PF-35PF-35PF-35
10' - 4 1/2"
4' - 10 1/2"4' - 10 1/4"3' - 9 1/2"4' - 0"PL-01
PL-01
CT-10.1
PA-401
12 121212
6.1
CW-K
D-112
WC-14
CT-10.1
9 10
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216ENLARGED PLAN ANDINTERIOR ELEVATIONS -EMPLOYEE, FITNESS &LAUNDRY LOUNGE
A-435
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
0'2' 4'8'
SCALE: 1/4" = 1'-0"
1/4" = 1'-0" Reference: 1 / A-121
9PUBLIC AND BOH ENLARGED PLAN
Fitness, Laundry Lounge, Employee Room, and Water Heater & Fire
1/4" = 1'-0" Reference: 9 / A-435
3 EMPLOYEE EAST ELEV.
Room 110
1/4" = 1'-0" Reference: 9 / A-435
4 EMPLOYEE SOUTH ELEV.
Room 110
1/4" = 1'-0" Reference: 9 / A-435
7 EMPLOYEE WEST ELEV.
Room 110
1/4" = 1'-0" Reference: 9 / A-435
8 EMPLOYEE NORTH ELEV.
Room 110
1/4" = 1'-0" Reference: 1 / A-431
6FITNESS NORTH ELEVATION
Room 114
1/4" = 1'-0" Reference: 9 / A-435
1FITNESS EAST ELEVATION
Room 114
1/4" = 1'-0" Reference: 1 / A-431
2FITNESS SOUTH ELEVATION
Room 114
1/4" = 1'-0" Reference: 9 / A-435
5FITNESS WEST ELEVATION
Room 114
1/4" = 1'-0" Reference: 9 / A-435
13 LAUNDRY LOUNGE S. ELEVATION
Room 114
1/4" = 1'-0" Reference: 9 / A-435
12 LAUNDRY LOUNGE W. ELEV.
Room 114
1/4" = 1'-0" Reference: 9 / A-435
11 LAUNDRY LOUNGE N. ELEVATION
Room 114
1/4" = 1'-0" Reference: 9 / A-435
10 LAUNDRY LOUNGE E. ELEV.
Room 114
FURNISHING SCHEDULE
GUESTROOM FURNISHINGS
GR-901 GUESTROOM DISHWASHER
GR-906GR-911 TELEVISION & TELEVISION MOUNT
PUBLIC AREA FURNISHINGS
PA-101 CHAIR - BANQUETTE
PA-113 CHAIR - BREAKROOM
PA-114 BENCH - FITNESS
PA-203 PENDANT LIGHT - PUBLIC RESTROOM
PA-308 TABLE - LAUNDRY LOUNGE SIDE TABLE
PA-312 TABLE - BREAKROOM TABLE
PA-401 ROLLER SHADE - PUBLIC/BOH -MANUAL, SHEER, WALL MOUNT, 5' W
PA-403 ROLLER SHADE - PUBLIC/BOH -MANUAL, SHEER/BLACK-OUT, WALLMOUNT, 8' W
PA-503 ART - LAUNDRY LOUNGE
PA-506 MIRROR - PUBLIC RESTROOM VANITY
PA-508 WALL-MOUNTED ROBE HOOK
PA-901 EMPLOYEE ROOM REFRIGERATOR
OWNER SPECIFIED - OWNER FURNISHED
OP-703 LAUNDRY CART
OP-705 FIRE EXTINGUISHER - ABC - 10 LBS
OP-706 FIRE EXTINGUISHER CABINET
PLUMBING/MECHANICAL FIXTURES
PF-02 TOILET - PUBLIC WALL MOUNT WITHFLUSHOMETER
PF-30 EYEWASH STATION
PF-31 SINK - BOH LAUNDRY
PF-35 LAUNDRY LOUNGE DRYER
PF-36 LAUNDRY LOUNGE WASHING MACHINE
PF-43 SINK - EMPLOYEE RESTROOMS
PF-45 REFRIGERATED BOTTLE FILLER (CUPSPROVIDED)
PUBLIC AREA FURNISHINGS
HD-25 PUBLIC AND STAFF RESTROOM GRABBARS
KEYNOTES - ENLARGED
1 2-WAY AREA OF REFUGE COMMUNICATION WITHFRONT DESK.
2 CARD READER TO CALL SERVICE ELEVATOR
3 CALL BUTTONS WITH LOCK PER AHJREQUIREMENTS.
4 ELEVATOR INDICATORS
5 AFTER-HOURS ACCESS INTERCOM-CONNECTED TO FRONT DESK.
6 KITCHEN HOOD VENT
7 FRP PANELS ON WALLS TO BE WELDED AT ALLSEAMS. ENSURE ALL SEAMS BETWEENDIFFERING MATERIALS ARE BACKED ANDSEALED IN ORDER TO MAINTAIN A SANITARY,WASHABLE ENVIRONMENT.
8 CLEAR TEMPERED, PLATED MIRROR
9 FLAT SCREEN TV.
10 PROVIDE ARTICULATING ARM FORWALL-MOUNTED TV.
11 PROVIDE FULL SUITES OF DATA/VIDEO/POWERUNDER AND BEWTEEN THE WINDOWS ALONGALL WALLS.
12 MACHINES TO BE SET UP FOR CARD ACCESSONLY. COORDINATE POWER AND DATA WITHSUPPLIER.
13 USE CORNER GUARDS ON ALL SURFACESFINISHED WITH WALL COVERING IN PUBLICAREAS.
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
Revision Schedule
Number Description Date
6.1
CT-15
WC-15
CT-11
PF-43
PF-02
HD-25
6.1
CT-15
WC-15
CT-15
WC-15
D-110A
PT-11
PL-11
6.1
CT-15
WC-15
PF-02
PF-43
CT-11
PF-02
PF-43
6.1
CT-15
WC-15
WC-15
PF-43
D-110B
CT-15
WC-15
PT-11
PL-11
6.1
B
A-436
6
A-4363 5
8
7
2
1
4
50 SF
EMP RR ADA
110A
30 SF
EMP RR
110B
D-110B D-110A
PF-02
HD-25
PF-43
PF-02PF-43
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216INTERIOR ELEVATIONS -EMPLOYEE RESTROOM
A-436
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
0'1' 2'4'
SCALE: 1/2" = 1'-0"
1/2" = 1'-0" Reference: 9 / A-436
5ADA EMPLOYEE RR E. ELEV.
Room 110A
1/2" = 1'-0" Reference: 9 / A-436
6ADA EMPLOYEE RR S. ELEV.
Room 110A
1/2" = 1'-0" Reference: 9 / A-436
7ADA EMPLOYEE RR W. ELEV.
Room 110A
1/2" = 1'-0" Reference: 9 / A-436
8 ADA EMPLOYEE RR N. ELEV.
Room 110A
1/2" = 1'-0" Reference: 9 / A-436
3EMPLOYEE RESTROOM W. ELEV.
Room 110B
1/2" = 1'-0" Reference: 9 / A-436
4EMPLOYEE RESTROOM N. ELEV.
Room 110B
1/2" = 1'-0" Reference: 9 / A-436
1EMPLOYEE RESTROOM E. ELEV.
Room 110B
1/2" = 1'-0" Reference: 9 / A-436
2EMPLOYEE RESTROOM S. ELEV.
Room 110B
1/2" = 1'-0" Reference: 9 / A-435
9 EMPLOYEE RESTROOM PLANS
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
Revision Schedule
Number Description Date
A-433
A-437
2
3
5
6
A-438
4
1
25
D-116
D-115
P1.1
P8
P7
P8
XE3P8P8
P3.1
P3.3
P1.1
P1.2
P8
A-4377
A-43863
4
171 SF
MEN'SRESTROOM
116
172 SF
WOMEN'S
RESTROOM
115
P8
9' - 0 1/4"5' - 2"8' - 11 3/4"6' - 11"
2' - 4 3/4"3' - 4 3/4"1' - 6"
2' - 8 3/4"3' - 9"2' - 8 3/4"2' - 1"4' - 10 3/4"2' - 1"1' - 7 1/4"1' - 6" 1' - 6" 1' - 8 3/4"5' - 1"5' - 1"
2' - 1 1/2"3' - 0"3' - 6"5' - 1 3/4"3' - 2"3' - 0 3/4" 1' - 6 1/4"
2' - 8 3/4"3' - 9"2' - 8 3/4"2' - 1"4' - 10 3/4"
2' - 5 1/2"2' - 1"2' - 1 1/2"2' - 1 1/2"3' - 10"5' - 1"1' - 0"5' - 1"3' - 11 1/2"2' - 1"2' - 5 1/2"
CT-10
CT-10
CT-10
CT-11
WC-15WC-15
WC-15
WC-15
PL-01
PA-506PA-506
HD-13
EQEQ
2' - 10"5' - 2"EQEQ
FREE STANDING TRASH RECEPTACLE
PL-01
SS-01
2' - 10"2' - 8 3/4"2' - 8 3/4"2' - 5 1/2"SS-01
PA-502
PA-203PA-203
P3.3
PA-507
PA-203WC-15 WC-15
PL-01
EQEQ
PA-506
1' - 0"1' - 0"CT-11 8' - 0"C
WC-15
WC-15CT-10.1
WC-15
1' - 0"8' - 0"CT-11
D-116
PT-11
8.1
WC-15
PA-203
PA-506
PL-011' - 0"8' - 0"2' - 10"CT-11
8.1
WC-15
CT-10.1
WC-15
2' - 10"PA-507
WC-15
3' - 10"1' - 0"737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216INTERIOR ELEVATIONS -PUBLIC RESTROOMPLAN AND INTERIORELEVATIONS
A-437
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
1/2" = 1'-0" Reference: 1 / A-431
1Lobby Restroom Enlarged Plan
1/2" = 1'-0"2Lobby Restroom Men's Elevation A
1/2" = 1'-0"3Lobby Restroom Men's Elevation B
1/2" = 1'-0"5Lobby Restroom Men's Elevation C
1/2" = 1'-0"6Lobby Restroom Men's Elevation D
1/2" = 1'-0"7 Lobby Restroom Men's Elevation D1
1/2" = 1'-0"4 Lobby Restroom Men's Elevation B1
KEYNOTES - UNIT BATHROOMS
A 2 CM ENGINEERED STONE COUNTERTOP SURFACE, STRAIGHTPROFILE WITH EASED EDGE
B 2 CM ENGINEERED STONE BACK SPLASH TO MATCH COUNTER TOP2 CM ENGINEERED STONE BACK SPLASH TO MATCH COUNTER TOP
C LAMINATE OVER 3/4" PLYWOOD
0'1' 2'4'
SCALE: 1/2" = 1'-0"
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
Revision Schedule
Number Description Date
1' - 0"8' - 0"WC-15WC-15
CT-10.1
CT-11
D-115
PT-111' - 0"8' - 0"PA-507
PA-203
PA-506
PL-01 2' - 10"CT-10.1
CT-11WC-15
PA-506 PA-506
HD-13
2' - 8 3/4"2' - 8 3/4"2' - 10"TO REFLECTIVE SURFACE3'-4" MAX.EQEQ
5' - 2"EQ EQ
2' - 10"PT-14
PT-14
PL-01
SS-01
PA-203
PT-14
CT-10.1FREE STANDING TRASH RECEPTACLE
PT-14
PA-502
CT-11
1' - 0"8' - 0"WC-15
PA-203
2' - 10"PL-01
WC-15
CT-10.1
WC-15
WC-15
CT-10.1
SS-01
PL-01
WC-152' - 10"CT-10.1
WC-15
4' - 9"3' - 10 1/2"4' - 6"PA-507
3' - 4"
4' - 6"
MIN.
3' - 6"TOILET SEAT HEIGHT1 ' - 5" - 1' - 7"REQ'D CLEAR1' - 0"REQ'D CLEAR0' - 1 1/2"GRIPPING SURFACE2'-9" - 2'-0"MIN.
3' - 0"1'-6" MIN.3'-3" - 3'-5"1' - 5"
3' - 5"
GRAB BAR(TOILET / 2-WALL AND VERTICAL)SURFACE MOUNTED
HD 06
NOTE: TYP. CLEAR AREA AROUND GRAB BARS TO BE : ABOVE - 1'-0", BELOW - 1'-5" . BETWEEN, SHOWER CONTROLS, SHOWER FITTING, AND OTHER GRAB BARS A CLEAR DISTANCE OF 1.5" IS PERMITTED.
MIN.
1' - 0"
MIN.
2' - 0"ACC.3' - 4"U.O.N.5' - 0"ROBE HOOKSURFACE MTD.
HD 12INSTALL BOTH ACC. AND NON ACC. COAT HOOK IN ACC. PUBLIC EMPLOYEE BATHAUTOMATIC PAPER TOWER DISPENSER
HD 13TO SHEET OR TOP OF CONTROL4' - 0"NOTE: MUST NOT PROJECT MORE THAN 4" INTO ACCESSIBLE ROUTE
TO OPERABLE PART3' - 10" MAX.NOTE: PROVIDE OVER HANDWASH SINK IN FOOD PREP
PROVIDE ADEQUATE CLEARANCE FROM FAUCET AND SINK
PAPER TOWEL /SOAP DISPENSERRECESSED
HD 173'6" - 3'-10" MAX.RECESSED WASTERECEPTACLEPOOL RESTROOMS
HD 19
NOTE: MUST NOT PROJECT MORE THAN 4" INTO ACCESSIBLE ROUTE
TO TRIM17" MAXURINAL WALL MOUNTED
HD 221'-9" MINNOTE: PROVIDE WOOD BLOCKING FOR ALL TOILET ACCESSORIES MOUNTED IN GYP. BD. PARTITIONS. MAINTAIN INTEGRITY OF FIRE RATING WHERE ACCESSORIES ARE IN RATED WALLS. REVIEW AND CONFIRM LOCAL CODES FOR ADDITIONAL ADA REQUIREMENTS.
TOILET TISSUE DISPENSER
HD 03
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216INTERIOR ELEVATIONS -PUBLIC RESTROOMRCP AND INTERIORELEVATIONS
A-438
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901 1/2" = 1'-0" Reference: 1 / A-437
1Lobby Restroom Women's Elevation A
1/2" = 1'-0" Reference: 1 / A-437
2Lobby Restroom Women's Elevation B
1/2" = 1'-0" Reference: 1 / A-437
4 Lobby Restroom Women's Elevation C
1/2" = 1'-0" Reference: 1 / A-437
5 Lobby Restroom Women's Elevation D
1/2" = 1'-0" Reference: 1 / A-437
6 Lobby Restroom Women's Elevation D1
1/2" = 1'-0"3 Lobby Restroom Women's Elevation B1
A B
C
AB
C
KEYNOTES - UNIT BATHROOMS
A 2 CM ENGINEERED STONE COUNTERTOP SURFACE, STRAIGHTPROFILE WITH EASED EDGE
B 2 CM ENGINEERED STONE BACK SPLASH TO MATCH COUNTER TOP2 CM ENGINEERED STONE BACK SPLASH TO MATCH COUNTER TOP
C LAMINATE OVER 3/4" PLYWOOD
0'1' 2'4'
SCALE: 1/2" = 1'-0"
3/4" = 1'-0"
PUBLIC TOILET ACCESSORIES LEGEND
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
Revision Schedule
Number Description Date
RB-10
PT-11PL-11
PT-03PT-03
RB-10
OP-705D-105 D-109
PL-11 PT-11
PL-11PT-11
56.146
PT-03
RB-10
PT-03
RB-10
PT-03
RB-10
PT-03
4
PT-03
RB-10
PT-03
RB-10
PL-11
PT-03
D-105A
PT-03
PT-03
RB-10
PT-03
RB-10
6.1
PT-03
RB-10
PL-11
PT-11
PT-03
D-109
RB-10
PT-03
5 6
PT-03
RB-10
RB-10
56
RB-11
546
RB-10
OPEN TO BOH DRYERS
D-107
PT-03PT-03PT-03PT-03
56.1
C
85 SF
LINENSTORAGE
109
56 SF
HOUSEKEEPINGOFFICE
109A
68 SF
ELEV 1
111
64 SF
ELEV 2
113
13 SF
LINEN CHUTE
140
131 SF
LINEN
DISCHARGE &SORTING
107
84 SF
BOH DRYERS
105A
750 SF
BOH LAUNDRY
105
3' - 4 1/2"
39' - 7 1/4"10' - 10"13' - 0 3/4"50' - 10"25' - 1 1/4"A-442
1
5
26
A-442
11
1210
A-44213
14
15
16
A-442
3
4
7
8
4
A-503
1
76
0' - 4"
12' - 2 1/4"2' - 0"2' - 0 1/2"D-105
D-109
D-107
7' - 0"0' - 7 1/4"
D-105A
7' - 8 1/4"5' - 1 1/2"8' - 11 3/4"737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216ENLARGED BOH PLAN &INTERIOR ELEVATIONS
A-442
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
0'2' 4'8'
SCALE: 1/4" = 1'-0"
1/4" = 1'-0" Reference: 1 / A-121
9BOH FLOOR PLAN - LAUNDRY
1/4" = 1'-0" Reference: 9 / A-442
1BOH LAUNDRY ELEVATION A
Room 105
1/4" = 1'-0" Reference: 9 / A-442
2BOH LAUNDRY ELEVATION B
Room 105
1/4" = 1'-0" Reference: 9 / A-442
5BOH LAUNDRY ELEVATION C
Room 105
1/4" = 1'-0" Reference: 9 / A-442
6BOH LAUNDRY ELEVATION D
Room 105
1/4" = 1'-0" Reference: 9 / A-442
11 BOH DRYER ELEVATION A
Room 105A
1/4" = 1'-0" Reference: 9 / A-442
10 BOH DRYER ELEVATION B
Room 105A
1/4" = 1'-0" Reference: 9 / A-442
12 BOH DRYER ELEVATION D
Room 105A
1/4" = 1'-0" Reference: 1 / A-403
13 LINEN DISCHARGE ELEVATION A
Room 107
1/4" = 1'-0" Reference: 9 / A-442
14 LINEN DISCHARGE ELEVATION B
Room 107
1/4" = 1'-0" Reference: 1 / A-403
15 LINEN DISCHARGE ELEVATION C
Room 107
1/4" = 1'-0" Reference: 9 / A-442
16 LINEN DISCHARGE ELEVATION D
Room 107
1/4" = 1'-0" Reference: 9 / A-442
3 HSK OFFICE/LINEN STO. ELEV. A
Room 109, 109A
1/4" = 1'-0" Reference: 9 / A-442
4 HSK OFFICE/LINEN STO. ELEV. B
Room 109, 109A
1/4" = 1'-0" Reference: 9 / A-442
7 HSK OFFICE/LINEN STO. ELEV. C
Room 109, 109A
1/4" = 1'-0" Reference: 9 / A-442
8 HSK OFFICE/LINEN STO. ELEV. D
Room 109, 109A
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
Revision Schedule
Number Description Date
5
WC-16
RB-11
PT-15
RB-10
5
RB-10
D-108A
PT-15
6" Standpipe4" Main Floor Sprinklers4" Dry SystemNitrogen Wall Mount System
1' - 10"2' - 2 1/2"1' - 6"WC-16
RB-11
3 3
K
D-128
K
WC-16
WC-16
RB-11
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216BOH INTERIORELEVATIONS
A-443
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
0'1' 2'4'
SCALE: 1/2" = 1'-0"
1/4" = 1'-0" Reference: 9 / A-435
1Electrical / Fire Elevation A
Room 108
1/4" = 1'-0" Reference: 9 / A-435
2Electrical / Fire Elevation B
Room 108 1/4" = 1'-0" Reference: 9 / A-435
3Electrical / Fire Elevation C
Room 108
1/4" = 1'-0" Reference: 9 / A-435
4 Electrical / Fire Elevation D
Room 108
1/4" = 1'-0" Reference: 1 / A-403
8 Water Heaters Elevation D
Room 104
1/4" = 1'-0" Reference: 9 / A-442
5Water Heaters Elevation A
Room 104
1/4" = 1'-0" Reference: 1 / A-403
6Water Heaters Elevation B
Room 104
1/4" = 1'-0" Reference: 9 / A-442
7Water Heaters Elevation C
Room 104
1/4" = 1'-0" Reference: 5 / A-434
9Electrical Elevation A
Room 128
1/4" = 1'-0" Reference: 1 / A-407
10Electrical Elevation B
Room 128
1/4" = 1'-0" Reference: 5 / A-434
11Electrical Elevation C
Room 128
1/4" = 1'-0" Reference: 1 / A-407
12Electrical Elevation D
Room 128
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
Revision Schedule
Number Description Date
3
3.1
2.1
DCB
1
A-443
8
5
6
7
A-4471
A-446
5
7
68
1.1
A
A-446
1
2
3
4
2
6' - 8 1/4"27' - 0"5' - 1 1/2"2' - 2"5' - 1 1/2"16' - 0"2' - 6"2' - 2"4' - 6 1/4"2' - 11 1/2"2' - 2"16' - 8"2' - 2"1' - 11 1/2"
2' - 6"
7' - 1 1/2"4' - 1 1/2"4' - 1 1/2"
R
3
'
-
0
"R 3' - 0"R
3
'
-
0
"R 3' - 0"5' - 8 1/4"Pool
432 SF
Splash Pad272 SF
2,152 SF
POOL &SPLASH PAD
101
80 SF
POOLRESTROOM
102
Pool Deck1,458 SF
204 SF
POOL MEP
103
548 SF
ELECTRICAL
104
711 SF
PUBLIC
CORRIDOR
10043 SF
VESTIBULE
100A0' - 4 1/2"36"x48"Clear Space
5' - 1 1/4"2' - 5 1/2"9' - 10"1' - 3"9' - 10"1' - 3"9' - 10"1' - 3"9' - 10"1' - 3"9' - 10"2' - 5 1/2"0' - 11 1/4"
CW-GCW-GCW-GCW-GCW-G
CW-F
CW-F
D-101
CW-L
D-103
D-102
D-101A
D-104D-100A
CW-F
CW-F
CW-F
0' - 6 3/4"4' - 0 1/2"2' - 3 1/4"5' - 0"3' - 6"5' - 0"3' - 6"5' - 0"1' - 6 1/4"4' - 3"0' - 4"3' - 4"7' - 0 1/2"12' - 4"10' - 5 1/4"5' - 0 1/4"
2' - 4"0' - 11 3/4"5' - 1"3' - 5"5' - 0"3' - 6"5' - 0"4' - 3"11' - 4"4' - 1"5' - 0"CW-F
10' - 10"
16' - 0"
D-104A16' - 8"W-EW-DW-E
D-100
CW-HCW-H
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216ENLARGED PLAN -POOL, SPLASH PAD,RESTROOM & MEP ANDELECTRICAL
A-444
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
0'2' 4'8'
SCALE: 1/4" = 1'-0"
1/4" = 1'-0" Reference: 1 / A-121
1
ENLARGED INDOOR POOL AND SPLASH PAD CONSTRUCTIONPLAN
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
Revision Schedule
Number Description Date
3
3.1
2.1
DCB
1
A-443
8
5
6
7
A-446
5
7
68
1.1
A
A-446
1
2
3
4
2
2' - 2"4' - 6 3/4"4' - 1 1/2"
2,152 SF
POOL &SPLASH PAD
101
80 SF
POOLRESTROOM
102
Pool Deck1,458 SF
204 SF
POOL MEP
103
548 SF
ELECTRICAL
104
711 SF
PUBLIC
CORRIDOR
100
43 SF
VESTIBULE
100A
5' - 1 1/4"2' - 5 1/2"9' - 10"1' - 3"9' - 10"1' - 3"9' - 10"1' - 3"9' - 10"1' - 3"9' - 10"2' - 5 1/2"0' - 11 1/4"
CW-GCW-GCW-GCW-GCW-G
CW-F
CW-F
D-101
CW-L
D-103
D-102
D-101A
D-104D-100A
CW-F
CW-F
CW-F
0' - 6 3/4"4' - 0 1/2"2' - 3 1/4"5' - 0"3' - 6"5' - 0"3' - 6"5' - 0"1' - 6 1/4"4' - 3"0' - 4"3' - 4"12' - 4"10' - 5 1/4"5' - 0 1/4"
2' - 4"0' - 11 3/4"5' - 1"3' - 5"5' - 0"3' - 6"5' - 0"4' - 3"11' - 4"4' - 1"5' - 0"CW-F
10' - 10"
16' - 0"
D-104A
36"x48"Clear Space
Aqua Shoot 3
Aqua Shroom 5Aqua Drop, 24" D, Radial
Aqua Drop, 24" D, Directional
Aqua Drop, 24" D, Radial
Aqua Bubbler, Typ
Splash Zone, Typ
Potential Location for Activation Button?Can it be wall-mounted?5' - 0"5' - 0"5' - 1 1/2"5' - 0"4' - 1 1/2"5' - 0"5' - 0"OF-712OF-712OF-705OF-705
OF-708OF-702
OF-706
OF-702
OF-702
OF-706
OF-706
OF-702
OF-708
OF-702
OF-708
OF-702
OF-706
OF-702
?
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216ENLARGED FFE PLAN-POOL, SPLASH PAD,RESTROOM & MEP ANDELECTRICAL
A-445
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
0'2' 4'8'
SCALE: 1/4" = 1'-0"
1/4" = 1'-0"1Enlarged Indoor Pool and Splash Pad Plan FFE Plan
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
Revision Schedule
Number Description Date
CB
SWIMMING POOLSPLASH PAD
2.11.1 2
CT-16CT-15 CT-15
CB 2.1 1.12
DD
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216INTERIOR ELEVATIONS -POOL & SPLASH PAD
A-446
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
FFL
FFL
1/4" = 1'-0"1Pool and Spash Pad Elevation A
1/4" = 1'-0"2 Pool and Spash Pad Elevation B
1/4" = 1'-0"3Pool and Spash Pad Elevation C
1/4" = 1'-0"4 Pool and Spash Pad Elevation D
FFL
1/4" = 1'-0"5Pool MEP Elevation A
1/4" = 1'-0"6Pool MEP Elevation B
1/4" = 1'-0"7Pool MEP Elevation C
1/4" = 1'-0"8 Pool MEP Elevation D
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
Revision Schedule
Number Description Date
2
A-447
2
3
45
A-44767D-102
1' - 11 1/4"1' - 9" 0' - 11 1/4" 2' - 6 1/4" 0' - 4" 2' - 6"4' - 6"0' - 6"1' - 5"3' - 0"3' - 5 1/2"
1' - 0"2' - 4 1/4"8' - 6 1/4"2' - 8"2' - 2"
10' - 0"
HD-24
HD-23HD-22HD-15
HD-14.21' - 6 3/4"1' - 5 1/4"2' - 8 1/2"HD-24
HD-14.2
HD-08.1
CT-15
3' - 4"0' - 8"1' - 10"2' - 11"HD-22
PA-518
PF-08
HD-15
HD-23
HD-11.31' - 6"2' - 11 1/2"CT-15
HD-11.2HD-22
HD-24
PF-02
CT-15
HD-15
PA-518
HD-24
EQ EQ
HD-11.2
PF-12
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216ENLARGED POOLRESTROOM DRAWINGS
A-447
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
0'1' 2'4'
SCALE: 1/2" = 1'-0"
1/2" = 1'-0" Reference: 1 / A-444
1Pool Restroom
Room 102
1/2" = 1'-0" Reference: 1 / A-447
2Pool Restroom Elevation A
Room 102
1/2" = 1'-0" Reference: 1 / A-447
3Pool Restroom Elevation C
Room 102
1/2" = 1'-0" Reference: 1 / A-447
4Pool Restroom Elevation B
Room 102
1/2" = 1'-0" Reference: 1 / A-447
5Pool Restroom Elevation D
Room 102
1/2" = 1'-0" Reference: 1 / A-447
6 Pool Shower Elevation B1
Room 102
1/2" = 1'-0" Reference: 1 / A-447
7 Pool Shower Elevation D1
Room 102
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
Revision Schedule
Number Description Date
5
C
4
255 SF
ENGINEERINGOFFICE &STORAGE
207
98 SF
PBX/MDF
207A
A-448
2
4
53
A-448
6
10
9
7
8' - 6 1/4"6' - 2 1/2"25' - 5 1/4"
11' - 9 1/4"13' - 8"
3' - 6"
2' - 2 1/2"
D-207A
D-207
D-207B
0' - 4 1/2"0' - 2 1/2"5
6.1
C
7
6
497 SF
LINENS &HOUSEKEEPING
209
5 SF
IDF
209B
A-448
11
6 SF
DAC
209C
12
13
14
2' - 2 3/4"13' - 6"5' - 4 3/4"2' - 10 1/2"8' - 3 3/4"12' - 11"3' - 9 3/4"3' - 8 1/4"D-207
D-X09B
D-X09C
D-X09
2' - 6 3/4"1' - 2"
WC-16
RB-11 RB-11
WC-16 WC-16
RB-11 RB-11
PL-11 PT-11
D-207AD-207
WC-16
RB-11
WC-16
PL-11
PT-11
D-207B D-207A
PT-11PL-11
D-207
6
3' - 4"D-X09C
PT-03
PL-02
STL
WC-16 PT-03 PT-03
C.1 6.1 6
D-X09BD-X09
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216ENLARGED PLAN &INTERIOR ELEVATIONS -OFFICE / STORAGE /PBX ROOM
A-448
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
1/4" = 1'-0" Reference: 1 / A-133
1Enlarged Engineering Office / Storage / PBX Floor Plan
Rooms 207 & 207A
1/4" = 1'-0" Reference: 1 / A-133
8Enlarged Linens and Housekeeping Plan
Room 209
1/4" = 1'-0" Reference: 1 / A-448
2Engineering Office / Sto. Elevation A
Room 207A
1/4" = 1'-0" Reference: 1 / A-448
3 Engineering Office / Sto. Elevation B
Room 207A 1/4" = 1'-0" Reference: 1 / A-448
4 Engineering Office / Sto. Elevation C
Room 207A
1/4" = 1'-0" Reference: 1 / A-448
5Engineering Office / Sto. Elevation D
Room 207A
FFL
FFL
FFL
FFL
1/4" = 1'-0" Reference: 1 / A-448
6PBX / MDF Elevation A
Room 207A
1/4" = 1'-0" Reference: 1 / A-448
7 PBX / MDF Elevation B
Room 207A
1/4" = 1'-0" Reference: 1 / A-448
9 PBX / MDF Elevation C
Room 207A
1/4" = 1'-0" Reference: 1 / A-448
10 PBX / MDF Elevation D
Room 207A
1/4" = 1'-0" Reference: 8 / A-448
11Linens & Housekeeping Elevation A
Room X09
1/4" = 1'-0" Reference: 1 / A-448
12 Linens & Housekeeping Elevation B
Room X09
1/4" = 1'-0" Reference: 8 / A-448
13Linens & Housekeeping Elevation C
Room X09
1/4" = 1'-0" Reference: 1 / A-448
14 Linens & Housekeeping Elevation D
Room X09
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
Revision Schedule
Number Description Date
ML.1KN P Q
7
8
428 SF
GUESTCORRIDOR
139A-450
2
3
4
5
28 SF
VESTIBULE
139A
1' - 10 1/4"5' - 9"30' - 2 1/4"14' - 1 3/4"24' - 5 1/4"5' - 7"1' - 11 1/4"2' - 4 1/4"
D-128D-X32
5' - 9"7' - 0"7' - 5 1/4"
7' - 10 3/4"0' - 3 3/4"
D-139A D-139B 2' - 0"A-450 78
L
ELECTRICAL
139B
7' - 0 1/2"9' - 4"
7' - 1 1/2"3' - 7 1/2"
7' - 3 3/4"3' - 10"5' - 2 1/2"5' - 8 1/2"5' - 5 1/4"5' - 11 1/4"D-G01D-G01D-G01 D-G01 D-G01
D-G01
D-G01
D-X15 D-G01
11' - 2 3/4"
ML.1NP
WC-11WC-10WC-11WC-10WC-11
RB-10 RB-10
WC-10
L
WC-10
D-G01D-G01D-G01D-G01 D-G01
PT-11 PL-01PT-11PL-01PT-11PL-01PT-11PL-01PT-11PL-01
OP-706 8
D-139A CW-H
WC-10
WC-11
WC-11
RB-10PC-04
ML.1NP
WC-10WC-11WC-10WC-11WC-10
RB-10 RB-10
D-X06
WC-10
L
D-G01D-X15
D-G01
D-G01D-G01A
PL-01PT-11PL-01PT-11PL-15PT-15PL-01PT-11PL-11PT-03 PL-01 PT-11
WC-11
8
WC-10
WC-11
CW-J
D-139
WC-11
RB-10
PC-04
FGE A-434A 56
K
7
8
H J
1,746 SF
GUESTCORRIDOR
215A-451
1
2
7' - 0"12' - 0 3/4"12' - 0 3/4"7' - 0 1/4"7' - 0"12' - 0 3/4"12' - 0 1/2"7' - 0 1/4"7' - 0 1/4"7' - 10 3/4"0' - 4 3/4"5' - 1" 0' - 7 1/2"5' - 8 1/2"5' - 1 1/4"5' - 8 1/2"5' - 1"5' - 8 1/2"7' - 0 1/4"7' - 0"7' - 0 1/4"7' - 0 1/4"5' - 1"D-G01D-G01D-G01 D-G01 D-G01
D-G01D-G01D-G01 D-G01 D-G01
12' - 0 3/4"
D-139B
PT-10
RB-10
PC-04
WC-10
D-139A
CW-H
PC-04
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216ENLARGED PLAN &INTERIOR ELEVATIONS -GUEST CORRIDOREAST WING
A-450
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
1/4" = 1'-0" Reference: 1 / A-122
1L01 GUEST CORRIDOR - EAST WING PLAN
FFL
1/4" = 1'-0" Reference: 5 / A-434
2L01 GUEST CORRIDOR - EAST WING - ELEVATION A
1/4" = 1'-0" Reference: 1 / A-450
3 L01 GUEST CORR. - EAST WING ELEV. B
FFL
1/4" = 1'-0" Reference: 5 / A-434
4L01 GUEST CORRIDOR - EAST WING ELEVATION C 1/4" = 1'-0" Reference: 1 / A-450
5 L01 GUEST CORR. - EAST WING ELEV. D
1/4" = 1'-0" Reference: 1 / A-134
6L02-L05 GUEST CORRIDOR - EAST WING PLAN - GRID E-K
1/4" = 1'-0" Reference: 1 / A-450
7 L01 GUEST CORR. - EAST WING ELEV. B1
1/4" = 1'-0" Reference: 1 / A-450
8 L01 GUEST CORR. - EAST WING ELEV. D1
0'2' 4'8'
SCALE: 1/4" = 1'-0"
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
Revision Schedule
Number Description Date
FGE KHJ2
A-301
WC-10
RB-10
WC-11WC-10WC-11 WC-10 WC-11
RB-10RB-10
D-G01D-G01D-G01 D-G01 929
PL-01PT-11PL-01PT-11
PL-01PT-11PL-01PT-11PL-01PT-11
FG EKHJ
2
A-301
WC-11WC-10WC-11WC-10 WC-11 WC-10
RB-10RB-10 RB-10
RB-10
OP-706
D-G01D-G01D-G01 D-G01 D-G01
PL-01PT-11PL-01PT-11PL-01PT-11 PL-01 PT-11 PL-01 PT-11
M
L.1
KN P Q
7
8
A-451
4
5
6
7
7' - 10 3/4"14' - 1 3/4"7' - 10 1/4"7' - 10 3/4"7' - 0 1/2"7' - 1 1/2"12' - 0 1/4"12' - 3 1/2"
D-X32
W-C
12' - 0 1/2"7' - 0 3/4"8' - 4 1/4"2' - 4 3/4"7' - 11"7' - 0 1/4"19' - 1 1/2"12' - 3 1/2"EQEQA-450 78
L
7' - 0 1/4"7' - 1 1/2"
2' - 10 1/4"5' - 8 1/2"5' - 5 1/4"7' - 0 1/2"7' - 1 1/2"5' - 11"D-G01D-G01D-G01 D-G01 D-G01
D-G01
D-X15
D-G015' - 2 1/4"2' - 3 1/4"ELECTRICAL
215A5' - 1 1/4"1' - 1"
ML.12
A-302
KN P
WC-11WC-10WC-11WC-10
RB-10RB-10RB-10 RB-10
WC-11
L
OP-706
D-G01D-G01D-G01D-G01D-G01
OP-706
PL-01 PT-11PL-01 PT-11PL-01PT-11PL-01PT-11PL-01PT-11
8
W-C
RB-10
PT-10
WC-11
RB-10
M L.1
2
A-302
KNP
PL-15WC-11WC-10 WC-11
RB-10RB-10
D-X32
L
D-G01AD-G01D-X15D-G01 D-G01
PL-01PT-11PL-11PT-03 PL-01 PT-11PL-01PT-11PL-01PT-11PT-15 8
OPEN TO BEYOND
WC-11
RB-10
WC-11
RB-10
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216ENLARGED PLAN &INTERIOR ELEVATIONS -GUEST CORRIDOREAST WING
A-451
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
FFL
FFL
1/4" = 1'-0" Reference: 6 / A-450
1TYP. LEVEL GUEST CORR.- EAST WING GRID E-K- ELEV. A
1/4" = 1'-0" Reference: 6 / A-450
2TYP. LEVEL GUEST CORR.- EAST WING GRID E-K- ELEV. C
1/4" = 1'-0"3TYP. LEVEL GUEST CORR. PLAN- EAST WING GRID K-Q
FFL
FFL
1/4" = 1'-0" Reference: 6 / A-450
4TYP. LEVEL GUEST CORR.- EAST WING GRID K-Q- ELEV. A
1/4" = 1'-0" Reference: 3 / A-451
5 TYP. LEVEL GUEST CORR.- EAST WING GRID K-Q- ELEV. B
1/4" = 1'-0" Reference: 6 / A-450
6TYP. LEVEL GUEST CORR.- EAST WING GRID K-Q- ELEV. C 1/4" = 1'-0" Reference: 3 / A-451
7 TYP. LEVEL GUEST CORR.- EAST WING GRID K-Q- ELEV. D
0'2' 4'8'
SCALE: 1/4" = 1'-0"
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
Revision Schedule
Number Description Date
FD
5
3
3.1
6.1
C.1 E
CB
8.1
4
7
8
6
A-452
2
35
4
A-45279
A-45268
A-452
10
11
2' - 1"5' - 6"5' - 6"5' - 10 3/4" 2' - 0 1/2"
W-EW-DW-E
D-101A
D-100A
CW-H
D-106
D-108
D-110
D-112
D-1147' - 10 1/4"6' - 10"4' - 1"5' - 2 3/4"0' - 9"
0' - 10 1/4"3' - 8"0' - 3 3/4"5' - 1 1/4"
CW-K
CW-K
14' - 0"5' - 6 1/2" 1' - 6 1/4"8' - 11 3/4"8' - 7"
1' - 7 1/2"
5' - 0"5' - 2 1/4"B
W-EW-DW-E
WC-10WC-10 WC-11
RB-10
RB-10 RB-10
D-101A
PC-04
3.1
D-104A
PL-11PT-11
B
OPEN TO CORRIDOR
WC-10 WC-10
RB-10
RB-10
CW-HD-100A
WC-10
PC-04
D-100ACW-H
WC-10
PC-04
D-100CW-H
PT-10
PC-04
53.1 6.11
A-3014 76
OPEN TO CORRIDORD-104A
RB-10
WC-10
PL-11PT-11
5 3.16.1 1
A-301 476
OPEN TO CORRIDOR
WC-10 WC-11 WC-10
WC-10
D-114 D-112
CW-K CW-K
RB-10 RB-10
D-110
PL-11 PT-11
D-108 D-106
PL-11 PT-11 PT-03PL-11PC-04PC-04 OP-706
PT-10
C.1 ECB
1
A-302
OPEN TO ELEVATOR LOBBY
OPEN TO CORRIDOR
WC-10 WC-11
WC-10
RB-10 RB-10
D-105
WC-12PL-11PT-11
C.1E C BWC-10
WC-10
RB-10
OPEN TO GUEST STO.
OP-706
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216ENLARGED PLAN &INTERIOR ELEVATIONS -GUEST CORRIDORWEST WING
A-452
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
1/4" = 1'-0" Reference: 1 / A-121
1L01 ENLARGED GUEST CORRIDOR PLAN - WEST WING
1/4" = 1'-0" Reference: 1 / A-452
2L01 GUEST CORRIDOR - WEST WING - ELEVATION A
1/4" = 1'-0" Reference: 1 / A-452
3 L01 GUEST CORR. - WEST WING - ELEV. B
1/4" = 1'-0" Reference: 1 / A-452
4 L01 GUEST CORRIDOR - WEST WING - ELEVATION C
1/4" = 1'-0" Reference: 1 / A-452
5L01 GUEST CORR. - WEST WING - ELEV. D
1/4" = 1'-0" Reference: 1 / A-452
7L01 GUEST CORR. - WEST WING - ELEV. F
1/4" = 1'-0" Reference: 1 / A-452
9L01 GUEST CORRIDOR - WEST WING - ELEVATION H
1/4" = 1'-0" Reference: 1 / A-444
6 L01 GUEST CORRIDOR - WEST WING - ELEVATION E
1/4" = 1'-0" Reference: 1 / A-444
8 L01 GUEST CORRIDOR - WEST WING - ELEVATION G
1/4" = 1'-0" Reference: 9 / A-435
10 L01 GUEST CORRIDOR - WEST WING - ELEVATION J
1/4" = 1'-0" Reference: 9 / A-435
11 L01 GUEST CORRIDOR - WEST WING - ELEVATION K
FFL
FFL
FFL
FFL
FFL
0'2' 4'8'
SCALE: 1/4" = 1'-0"
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
Revision Schedule
Number Description Date
5
3
3.1
2.1
CB
4
1.1
2
6
A-4546
1
3
4
A-454
2
5
2' - 8 1/2"
W-C
D-G01
D-G01
D-X15B
D-X06
D-G01
D-G01
D-207B
D-G019' - 11"2' - 11"14' - 1"9' - 4 3/4"19' - 1 3/4"1' - 9 1/2" 3' - 8 3/4"11' - 4"1' - 10 1/2"5' - 6"10' - 7"17' - 1 3/4"2' - 2"10' - 7"2' - 10" 1' - 10 1/4" 4' - 8 3/4"9' - 11"5' - 2 1/2"7' - 1 1/2"5' - 7 1/4"7' - 1"1' - 3 1/4"5' - 5"
5' - 5 1/2"
5' - 6"1' - 10"2' - 0"1' - 1 1/2"1' - 8 1/2"8' - 0 1/2"2' - 10"0' - 7 1/4"5' - 6 1/4"0' - 3"
5' - 8 1/4"
6.1 C.1 E
CB
8.1
9
7
8
6
A-45410
7
8
9
5' - 1 3/4"1' - 6 1/2"
0' - 0 3/4"5' - 5" 0' - 4 1/2"1' - 9 1/4"5' - 8 1/4"11' - 9 3/4"0' - 4"10' - 8 3/4"1' - 3 3/4"0' - 4" 7' - 1 1/4" 0' - 4" 6' - 9"7' - 2 1/4" 0' - 11 3/4"
1' - 0"3' - 2 1/4"8' - 3 3/4"12' - 9 1/2"D-G01
D-X09
D-G01
18' - 4 1/2"11' - 6"5' - 8 1/2" 1' - 10 1/4"
7' - 4 1/4"12' - 0 1/4"12' - 0 3/4"7' - 0 1/4"
4' - 11 1/2"
5' - 2 3/4"
4' - 11 3/4"
5' - 7 1/2"5' - 1"D-X17
5' - 5 1/4"D-G01
5' - 11 1/2"5' - 8 1/2"D-G01 D-G01
A-504
4
53
5
8
7
6
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216ENLARGED PLAN &INTERIOR ELEVATIONS -TYP. LVL. GUESTCORRIDOR WEST WING
A-453
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
1/4" = 1'-0" Reference: 1 / A-123
1L02-05 ENLARGED GUEST CORR.- WEST WING - GRID 1.1 - 6.1
1/4" = 1'-0" Reference: 1 / A-123
2L02-05 ENLARGED GUEST CORR.- WEST WING - GRID 6 - 8
0'2' 4'8'
SCALE: 1/4" = 1'-0"
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
Revision Schedule
Number Description Date
WC-10
D-X15BPL-15
RB-10
PT-15
533.12.1
3
A-302
42 6
D-G01 D-G01 D-207B
WC-11 WC-10 WC-11 WC-10 WC-11 WC-02
RB-10RB-10RB-10PT-11PL-01
D-G106
PT-11PL-01 PT-11PL-01 PT-11
OPEN TO CORRIDOR
WC-10
RB-10
5 33.1 2.1
3
A-302
4 26
D-G01D-G01 D-X06 D-G01
WC-11 WC-10 WC-10 WC-11 WC-11 WC-10
RB-10RB-10RB-10
D-G01
PL-01PT-11PL-01PT-11 PL-11 PT-03 PL-01 PT-11 PL-01 PT-11
OP-706
PT-10
RB-10
W-C
WC-10
D-X15B
PL-15
PT-15
DC.1EC
1
A-302
OPEN TO CORRIDORD-X17
WC-10WC-10
RB-10RB-10
OP-706
PL-15
PT-15WC-10
6.1
1
A-301
8.1786
OPEN TO CORRIDOR
WC-10 WC-10 WC-10
RB-10RB-10
D-X09
PL-11PT-11
OP-706
C.1EC
1
A-302
OPEN TO CORRIDOR
WC-10WC-11WC-10
RB-10RB-10RB-10
PT-10
PT-10
PL-01PT-11PL-01PT-11
W-C
D-G01D-G01
6.1
1
A-301
8.1 78 6
D-G01 D-G01
WC-10 WC-11 WC-11 WC-10 WC-10 WC-11
RB-10 RB-10 RB-10
OP-706
PT-11PL-01PT-11PL-01
D-G01
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216INTERIOR ELEVATIONS -TYP. LVL. GUESTCORRIDOR WEST WING
A-454
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
FFL
FFL
1/4" = 1'-0" Reference: 1 / A-453
1TYP. LVL. GUEST CORR.- WEST WING ELEV. A
1/4" = 1'-0" Reference: 1 / A-453
3TYP. LEVEL GUEST CORRIDOR- WEST WING ELEV. B
1/4" = 1'-0" Reference: 1 / A-453
4TYP. LVL. GUEST CORR.- WEST WING ELEV. C
1/4" = 1'-0" Reference: 1 / A-453
6TYP. LEVEL GUEST CORRIDOR- WEST WING ELEV. D
1/4" = 1'-0" Reference: 1 / A-453
2TYP. LVL. GUEST CORR.- WEST WING ELEV. A1
1/4" = 1'-0" Reference: 1 / A-453
5TYP. LVL. GUEST CORR.- WEST WING ELEV. C1
FFL
1/4" = 1'-0" Reference: 1 / A-422
7TYP. LEVEL GUEST CORRIDOR- WEST WING ELEV. E
1/4" = 1'-0" Reference: 1 / A-453
8TYP. LEVEL GUEST CORRIDOR- WEST WING ELEV. F
FFL
1/4" = 1'-0" Reference: 1 / A-422
9TYP. LEVEL GUEST CORRIDOR- WEST WING ELEV. G 1/4" = 1'-0" Reference: 1 / A-453
10TYP. LEVEL GUEST CORRIDOR- WEST WING ELEV. H
0'2' 4'8'
SCALE: 1/4" = 1'-0"
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
Revision Schedule
Number Description Date
UP
UP
DN
DN
3.1
B
4
4
A-501
-0' - 0 1/2"
7' - 1 1/4"4' - 0 1/2"0' - 4 3/4"4' - 0 3/4"4' - 0 1/2"
13 EQ TREADS
11' - 11"
CPT-14CPT-14
P4.2
P4.1
P4.2
P1.2XE1/2
D-106A
D-106
3.1
B
4
4
A-501
4' - 0 1/2"
9 EQ TREADS
8' - 3"10' - 9 1/4"
7' - 1 1/4"4' - 0 1/2"
13 EQ TREADS
11' - 11"
CPT-14CPT-14
D-X06
P4.2
P4.1
P4.2
XE1/2
P1.2
3.1
B
4
4
A-501
4' - 0 1/2"19' - 0 1/4"
CPT-14CPT-14
P4.2
P4.1
P4.2
XE1/2
P1.2
D-X06
4' - 0 1/2"
9 EQ. TREADS
8' - 3"10' - 9 1/4"
FLOOR 10' - 0"
FLOOR 216' - 0"
FLOOR 327' - 0"
FLOOR 549' - 0"
MAIN ROOF61' - 2"
BO ROOF STRUC.60' - 0"
LOW PARAPET63' - 10"
B
SITE-0' - 6"3' - 10 1/2"TYP.3' - 0"TYP.3' - 0"28 EQ RISERS16' - 0"8' - 0"20 EQ RISERS11' - 0" (TYP. 2ND-5TH FLOOR)5' - 6"5' - 6"3' - 6"3' - 0"ACT ACOUSTIC CEILING TILEASALUMINUM STOREFRONTCGCORNER GUARDCONC CONCRETE, UNFINISHEDCPCARPETCPTCARPET TILECSCONCRETE, FINISHEDGWBGYPSUM WALL BOARDFCFIBER CEMENTFRPFIBERGLASS-REINFORCEDPLASTICMR GWB MOISTURE-RESISTANT GYPSUM WALL BOARDPLPLASTIC LAMINATEPTPAINT/POWDER COATQTQUARRY TILERBRUBBER BASERESRESILIENT TILE FLOORSCSTAMPED CONCRETESFSPECIALTY FINISH (KNOCK DOWN)SS ENGINEERED SOLID SURFACESTSTONESTLSTAINLESS STEELSTRUC STRUCTURE ABOVEVCTVINYL COMPOSITE TILEWCVINYL WALL COVERINGWDWOOD-LOOK ALUMINUM SLATS AND BATTENSWPSCREEN WALL
NOTE: REFER TO FF&E PACKAGE AND SPECIFICATION BOOK FOR FURNITURE AND FINISH SPECIFICATIONS
FINISH LEGEND
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216STAIR 1 DETAILS
A-501
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
3/8" = 1'-0" Reference: 1 / A-121
1STAIR 1 PLAN - 1ST FLOOR
Room 106
3/8" = 1'-0" Reference: 1 / A-123
2STAIR 1 PLAN - 2ND - 4TH FLOOR, TYP.
Room 106
3/8" = 1'-0" Reference: 1 / A-105
3STAIR 1 PLAN - 5TH FLOOR
Room 106
3/8" = 1'-0" Reference: 1 / A-501
4STAIR 1 SECTION
Room 106 0'1'-4" 2'-8"5''-4"
SCALE: 3/8" = 1'-0"
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
Revision Schedule
Number Description Date
UP
UP
DN
DN
M
L.1
9
4
A-502
8
4' - 10"0' - 4 1/2"4' - 9 1/2"4' - 11"
13 EQ TREADS
12' - 0"6' - 2"
D-X32D-G107
P4.3
P4.1
P4.1
XE1/2P1.2
CPT-14CPT-14
M
L.1
9
4
A-502
5' - 0"
13 EQ. TREADS
11' - 11"6' - 2"4' - 10"0' - 4 3/4"4' - 9 1/2"8
5' - 0"
9 EQ TREADS
8' - 3"9' - 10"
P4.3
P4.1
P4.1
XE1/2
D-X32
P1.2
CPT-14CPT-14
M
L.1
9
4
A-502
8' - 7"
5' - 0"
9 EQ TREADS
8' - 3"9' - 10"4' - 10"8
ROOF ACCESS
539D-532
D-X32
XE1/2
P4.3
P4.1
P4.1
P1.2
P10
P1.2
CPT-14CPT-14
CPT-14
FLOOR 10' - 0"
FLOOR 216' - 0"
FLOOR 327' - 0"
FLOOR 549' - 0"
MAIN ROOF61' - 2"
BO ROOF STRUC.60' - 0"
LOW PARAPET63' - 10"
SITE-0' - 6"
9
TYP.3' - 0"28 EQ. RISERS16' - 0"20 EQ RISERS11' - 0" (TYP. LEVEL 02-05)3' - 10 1/2"8
ROOF ACCESS
539
P10
ACT ACOUSTIC CEILING TILEASALUMINUM STOREFRONTCGCORNER GUARDCONC CONCRETE, UNFINISHEDCPCARPETCPTCARPET TILECSCONCRETE, FINISHEDGWBGYPSUM WALL BOARDFCFIBER CEMENTFRPFIBERGLASS-REINFORCEDPLASTICMR GWB MOISTURE-RESISTANT GYPSUM WALL BOARDPLPLASTIC LAMINATEPTPAINT/POWDER COATQTQUARRY TILERBRUBBER BASERESRESILIENT TILE FLOORSCSTAMPED CONCRETESFSPECIALTY FINISH (KNOCK DOWN)SS ENGINEERED SOLID SURFACESTSTONESTLSTAINLESS STEELSTRUC STRUCTURE ABOVEVCTVINYL COMPOSITE TILEWCVINYL WALL COVERINGWDWOOD-LOOK ALUMINUM SLATS AND BATTENSWPSCREEN WALL
NOTE: REFER TO FF&E PACKAGE AND SPECIFICATION BOOK FOR FURNITURE AND FINISH SPECIFICATIONS
FINISH LEGEND
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216STAIR 2 DETAILS
A-502
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
3/8" = 1'-0" Reference: 1 / A-122
1STAIR 2 PLAN - 1ST FLOOR
Room 132
3/8" = 1'-0"2STAIR 2 PLAN - 2ND - 4TH FLOOR TYP.
3/8" = 1'-0" Reference: 1 / A-105
3STAIR 2 PLAN - 5TH FLOOR
Room 132
3/8" = 1'-0" Reference: 1 / A-502
4STAIR 2 SECTION
Room 132
0'1'-4" 2'-8"5''-4"
SCALE: 3/8" = 1'-0"
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
Revision Schedule
Number Description Date
FLOOR 10' - 0"
FLOOR 216' - 0"
FLOOR 327' - 0"
FLOOR 549' - 0"
MAIN ROOF61' - 2"
BO ROOF STRUC.60' - 0"
MIDDLE PARAPET65' - 10"
SITE-0' - 6"11' - 0"16' - 0"DOOR OPENING7' - 0" TYP.22' - 0"TYP. LEVEL 03 TO 05 @ 11' FLR TO FLR HEIGHTSHAFTELEVATOR PIT5' - 0"XD4
XD4
P5.1P5.2
P5.1P5.2
XD6
XD6
P5.2P5.1
5
4
A-503
6
3
A-5038' - 8"0' - 7 1/2"4' - 4 3/4"VER.3' - 6"2' - 7"VER.3' - 6"9' - 1"0' - 7 1/2"ELEV 1
111
ELEV 2
1132' - 9 1/4"2' - 6 1/4"2' - 5 1/4"3' - 6"4' - 0 1/2"P5.1
P5.4
P5.2
P5.4
P5.3
XE4
XE4
XE4
P5.5
P5.5
XE1/2
8' - 8"D-X13
D-X11
D-X11A
LINEN CHUTE
140
4
A-503
6
3
A-503
ELEV 2
113
ELEV 1
111
P5.4
XD6
XD6
XD6
XD6
FLOOR 10' - 0"
FLOOR 216' - 0"
FLOOR 327' - 0"
FLOOR 549' - 0"
MAIN ROOF61' - 2"
6.1
BO ROOF STRUC.60' - 0"
SITE-0' - 6"
6
SHAFTSHAFTDOOR OPENING7' - 0" TYP.XD6 XD6
P5.4
P5.3
P5.4
P5.3
P5.4
P5.4
P5.4
XE4
P5.3 4' - 9"SAFETY BEAM(NOT BY OTIS)
TOP RAIL SUPPORT(NOT BY OTIS)
CRITICAL
LOCATION
CRITICAL
LOCATION
SECOND RAIL SUPPORT(NOT BY OTIS)
(ONLY REQUIRED ON THE OPPOSITE SIDE OF CWT.)4" MINCRITICAL
LOCATION
CENTER OF RAIL BRACKETSEE SECTIONAL ELEVATIONTOP LANDING
** ALL LOCATION DIMENSIONS TO FOLLOW A TOLERANCE OF ±1"JAMB DEPTHMINIMUM2 LAYERS OF 1/2" DRYWALL (MINIMUM) REQUIRED AT BACK OF CONTROLLER.WALL DEPTHMINIMUMCONDITIONPER BUILDINGALTERNATE CONSTRUCTION
ELEVATOR LOBBY CONTROLLER
2' - 2" MINIMUM
TUBE STEEL FLUSH WITH HOISTWAY (NOT BY OTIS)1' - 1"4' - 3 13/16"INSIDE HOISTWAY
TUBE STEEL FLUSH WITH HOISTWAY (NOT BY OTIS)1' - 1"4' - 3 13/16"TUBE STEEL FLUSH WITH HOISTWAY (NOT BY OTIS)
TUBE STEEL FLUSH WITH HOISTWAY (NOT BY OTIS)
INSIDE HOISTWAY
2' - 5 5/8"2' - 5 5/8"LADDER
0' - 4 1/2"
1" MAX
LADDER16"SILL ASSEMBLY(BY OTIS)
FINISHED FLOOR
GROUT STOPDOOR SPACE
FRONT WALL LINE
SILL LINE
ADEQUATE SUPPORT AT ALL FASTENING POINTS OF ENTRANCE ASSEMBLY REQUIRED. MUST WITHSTAND HORIZONTAL PULL-OUT FORCE OF 140 LBS. @ EA. FASTENING POINT (8 @ EA. ENTRANCE) INCLUDING SUPPORT FOR CENTER SILL SUPPORT BRACKET (NOT BY OTIS)
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216ELEVATOR DETAILS
A-503
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
3/8" = 1'-0" Reference: 1 / A-503
4ELEVATOR CROSS SECTION
3/8" = 1'-0" Reference: 1 / A-431
1ELEVATOR SHAFT PLAN
0'6" 1'2'
SCALE: 1" = 1'-0" 3/8" = 1'-0"2ELEVATOR PIT PLAN
3/8" = 1'-0"3ELEVATOR LONGITUDINAL SECTION
3/16" = 1'-0"5 MACHINE DETAIL
1" = 1'-0"6 FRONT TOP LANDING ENTRANCE REQUIREMENTS NO. 2
3/4" = 1'-0"7 TUBE STEEL RAIL BRACKET SUPPORT
1/2" = 1'-0"9 LADDER DETAIL
1" = 1'-0"8 DETAIL "A" SILL SUPPORT
0'8" 1' 4"2' 8"
SCALE: 3/4" = 1'-0"
0'1' 2'4'
SCALE: 1/2" = 1'-0"
0'1'-4" 2'-8"5''-4"
SCALE: 3/8" = 1'-0"
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
Revision Schedule
Number Description Date
E
176 SF
ELEVATORLOBBY
117
64 SF
ELEV 2
113
68 SF
ELEV 1
1114
A-503
8' - 2 1/4"0' - 4 3/4"
A-43315
13
14
7
6
3
A-503
D-117
D-X11
D-X13
D-X11A
LINEN CHUTE
140
E
4
A-503
157 SF
ELEVATOR
LOBBY
217
D-X17
W-C
4' - 0"2' - 3 1/4"0' - 5 1/4"19' - 3"68 SF
ELEV 1
111
64 SF
ELEV 2
113
7
6
3
A-503
D-X13
D-X11
D-X11A A-504
4
53
1
A-301
3' - 0"4' - 0"PA-504
CENTER ON ELEVATOR DOORS
1
WC-11
RB-10
1
A-301
4
A-503
ELEVATOR DOORELEVATOR DOOR
2
4
3
PA-204PA-204
EQEQ
3' - 10"3' - 10"6' - 0"7' - 0"WC-11
RB-10
W-C
WC-11
RB-10
ACT ACOUSTIC CEILING TILEASALUMINUM STOREFRONTCGCORNER GUARDCONC CONCRETE, UNFINISHEDCPCARPETCPTCARPET TILECSCONCRETE, FINISHEDGWBGYPSUM WALL BOARDFCFIBER CEMENTFRPFIBERGLASS-REINFORCEDPLASTICMR GWB MOISTURE-RESISTANT GYPSUM WALL BOARDPLPLASTIC LAMINATEPTPAINT/POWDER COATQTQUARRY TILERBRUBBER BASERESRESILIENT TILE FLOORSCSTAMPED CONCRETESFSPECIALTY FINISH (KNOCK DOWN)SS ENGINEERED SOLID SURFACESTSTONESTLSTAINLESS STEELSTRUC STRUCTURE ABOVEVCTVINYL COMPOSITE TILEWCVINYL WALL COVERINGWDWOOD-LOOK ALUMINUM SLATS AND BATTENSWPSCREEN WALL
NOTE: REFER TO FF&E PACKAGE AND SPECIFICATION BOOK FOR FURNITURE AND FINISH SPECIFICATIONS
FINISH LEGEND
3/8" = 1'-0" Reference: 1 / A-122
11ST FLOOR ELEVATOR LOBBY
Room 117
3/8" = 1'-0" Reference: 1 / A-124
22ND-5TH FLOORS (TYPICAL) ELEVATOR LOBBY
Rooms 217, 317, 417 & 517
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216ELEVATOR LOBBYDETAILS
A-504
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
0'1'-4" 2'-8"5''-4"
SCALE: 3/8" = 1'-0"
3/8" = 1'-0" Reference: 1 / A-102
5TYP. ELEVATOR LOBBY - EAST ELEVATION
Rooms 217, 317, 417 & 517
3/8" = 1'-0" Reference: 1 / A-102
3TYP. ELEVATOR LOBBY - WEST ELEVATION
Rooms 217, 317, 417 & 517
FURNISHING SCHEDULE
GUESTROOM FURNISHINGS
GR-103 CHAIR - KITCHEN STOOL
GR-201 SCONCE - NIGHTSTAND
GR-308 NIGHTSTAND - REGULAR
GR-318 DRESSER - HIGHBOY
GR-326 VANITY - STUDIO AND 1-BEDROOMSUITES
GR-503 ART- ENTRY
GR-506 MIRROR - GUESTROOM FULL LENGTH
GR-508 MIRROR - GUESTROOM VANITY
GR-907 CLOCK/RADIO
GR-908 TELEPHONE - GUESTROOM
GR-KS BED - KING (GR-301, 303, 600)
PUBLIC AREA FURNISHINGS
PA-100 BENCH - DINING ROOM BANQUETTE
PA-204 SCONCE - PUBLIC AREAS
PA-504 ART - TYPICAL ELEVATOR LOBBY
PA-505 ART - 1ST FLOOR ELEVATOR LOBBY
PLUMBING/MECHANICAL FIXTURES
PF-01 TOILET - GUESTROOM
PF-07 LAVATORY - UNDERMOUNT, 20" X 14"
PF-15 FAUCET - LAVATORY
TOILET ACCESSORIES
HD-01 DUAL TOILET PAPER HOLDER
HD-04.1 TOWEL BAR
HD-21 BULK AMENITY DISPENSER ATLAVATORIES
KEYNOTES - ENLARGED
1 2-WAY AREA OF REFUGE COMMUNICATION WITHFRONT DESK.
2 CARD READER TO CALL SERVICE ELEVATOR
3 CALL BUTTONS WITH LOCK PER AHJREQUIREMENTS.
4 ELEVATOR INDICATORS
5 AFTER-HOURS ACCESS INTERCOM-CONNECTED TO FRONT DESK.
6 KITCHEN HOOD VENT
7 FRP PANELS ON WALLS TO BE WELDED AT ALLSEAMS. ENSURE ALL SEAMS BETWEENDIFFERING MATERIALS ARE BACKED ANDSEALED IN ORDER TO MAINTAIN A SANITARY,WASHABLE ENVIRONMENT.
8 CLEAR TEMPERED, PLATED MIRROR
9 FLAT SCREEN TV.
10 PROVIDE ARTICULATING ARM FORWALL-MOUNTED TV.
11 PROVIDE FULL SUITES OF DATA/VIDEO/POWERUNDER AND BEWTEEN THE WINDOWS ALONGALL WALLS.
12 MACHINES TO BE SET UP FOR CARD ACCESSONLY. COORDINATE POWER AND DATA WITHSUPPLIER.
13 USE CORNER GUARDS ON ALL SURFACESFINISHED WITH WALL COVERING IN PUBLICAREAS.
3/8" = 1'-0" Reference: 2 / A-453
4TYP. ELEVATOR LOBBY - S. ELEV.
Rooms 217, 317, 417 & 517
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
Revision Schedule
Number Description Date
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216CANOPY DETAILS
A-505
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
3/8" = 1'-0" Reference: 1 / A-102
1PORTE COCHERE EAST-WEST SECTION
3/8" = 1'-0" Reference: 1 / A-102
3PORTE COCHERE NORTH-SOUTH SECTION
3/4" = 1'-0" Reference: 3 / A-505
2 CANOPY DETAIL AT LOBBY ENTRANCE 0'8" 1' 4"2' 8"
SCALE: 3/4" = 1'-0"
0'1'-4" 2'-8"5''-4"
SCALE: 3/8" = 1'-0"
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
Revision Schedule
Number Description Date
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216CANOPY DETAILS
A-506
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
1 1/2" = 1'-0" Reference: 1 / A-505
1PORTE COCHERE SLOPED EDGE
3/4" = 1'-0" Reference: 3 / A-505
2PORTE COCHERE AT ROOF DRAIN
0'4" 8"1' 4"
SCALE: 1 1/2" = 1'-0"
0'6" 1'2'
SCALE: 1" = 1'-0"
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
Revision Schedule
Number Description Date
MAIN ROOF61' - 2"
BO ROOF STRUC.60' - 0"
LOW PARAPET63' - 10"
MIDDLE PARAPET65' - 10"
HIGH PARAPET69' - 10"
MAX BLDG HEIGHT71' - 2"
910
1' - 4"4' - 0"2' - 0"2' - 8"737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216ROOF DETAILS
A-507
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
3/4" = 1'-0" Reference: 1 / A-106
1ROOF PARAPET HEIGHTS
0'8" 1' 4"2' 8"
SCALE: 3/4" = 1'-0"
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
Revision Schedule
Number Description Date
REINFORCING MESH AND BASE COAT EMBEDDED. NOTE. 2 1/2" (63MM) MIN. OVERLAP AT REINFORCING MESH
REINFORCING MESH EMBEDDED IN BASE COAT
FINISH
EXPANDED POLYSTYRENE
MIN. 3/4" (19 MM)
MIN. 3/4" (19 MM)
PITCH FOR POSITIVE DRAINEDGE
ADHESIVE
EXPANDED POLYSTYRENE
REINFORCING MESH EMBEDDED IN BASE COAT
FINISH
SEE DETAILS FOR EXPANSION JOINT SEE DETAILS FOR EXPANSION JOINT
ADHESIVE
EXPANDED POLYSTYRENE
REINFORCING MESH EMBEDDED IN BASE COAT
FINISH
INSULATION SUBSTRATE
ADHESIVE
EXPANDED POLYSTYRENEBLOCKING
ELASTOMERIC SEALANT
CORROSION RESISTANT FASTENER
P.V.C. PIPE SLEEVE FILLED WITH ELASTOMERIC SEALANT
FINISH
REINFORCING MESH EMBEDDED IN BASE COAT
PVC PIPE SLEEVE INSERTED INTO PRE-DRILLED HOLES
FRAMING
SHEATHING
EXPANDED POLYSTYRENE
HANDRAIL POST
PRE-DRILLED HOLES
ILLUSTRATION "A"ILLUSTRATION "B"
ELASTOMERIC SEALANT
FASTENER
EXPANDED POLYSTYRENE
ADHESIVE
DOUBLE WRAP WITH REINFORCING MESH EMBEDDED BASE COAT
FINISH
FINISH
REINFORCING MESH EMBEDDED IN BASE COAT
EXPANDED POLYSTYRENE
ADHESIVE
MESH BACKWRAP
CLOSED CELL POLYETHYLENE BACKER ROD AND ELASTOMERIC SEALANT, JOINT WIDTH MINIMUM 3/4" (19MM).
JAMB
CLOSED CELL POLYETHYLENE BACKER ROD AND ELASTOMERIC SEALANT
DOUBLE WRAPPED REINFORCING MESH EMBEDDED IN BASE COAT
FINISH
REINFORCING MESH EMBEDDED IN BASE COAT
EXPANDED POLYSTYRENE
ADHESIVE
SUBSTRATE
SUBSTRATE
ADHESIVE
EXPANDED POLYSTYRENE
REINFORCING MESH EMBEDDED IN BASE COAT
FINISH
3/4" (19 MM) MIN. EXPANDED POLYSTYRENE SEE THICKNESS FOR GROOVE
OUTSIDE CORNER SEE DETAIL3" (75 MM) MAX.
INSIDE CORNER SEE DETAIL
ADHESIVE
EXPANDED POLYSTYRENE
DOUBLE WRAP WITH REINFORCING MESH EMBEDDED BASE COAT
FINISH
SUBSTRATEADHESIVE
EXPANDED POLYSTYRENE
RECOMMENDED HIGH IMPACT REINFORCING MESH EMBEDDED IN BASE COAT
REINFORCING MESH EMBEDDED IN BASE COAT
FINISH
MESH BACKWRAP
FOUNDATION 6" (150 MM) MIN TO GRADE
INSULATION
SUBSTRATE
ADHESIVE
EXPANDED POLYSTYRENE
RECOMMENDED HIGH IMPACT REINFORCING MESH EMBEDDED IN BASE COAT
REINFORCING MESH EMBEDDED IN BASE COAT
FINISH
MESH BACKWRAP
FOUNDATION PAVEMENT
2" (50 MM) MIN.
INSULATION
SUBSTRATEADHESIVE
EXPANDED POLYSTYRENE
REINFORCING MESH EMBEDDED IN BASE COAT
FINISH
MESH BACKWRAP
INSULATION
CLOSED CELL BACKER ROD AND ELASTOMERIC SEALANT
BALCONY DECK
ELASTOMERIC SEALANT
WATERTIGHT ELECTRICAL BOX/HOSE BIBB
SHEATHING
ADHESIVE
EXPANDED POYSTYRENE
ELASTOMERIC SEALANT
FIXTURE
BOX COVER
REINFORCING MESH EMBEDDED IN BASE COAT
FINISH
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216EIFS DETAILS
A-509
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
3" = 1'-0"1AESTHETIC GROOVE REVEAL
3" = 1'-0"2BUILDING ISOLATION JOINT
0'1" 2"4"
SCALE: 6" = 1'-0"
3" = 1'-0"3DISSIMILAR SUBSTRATES
3" = 1'-0"4 FIXTURE ATTACHMENT (BY OTHERS)
3" = 1'-0"5HANDRAIL ATTACHMENT (BY OTHERS)
6" = 1'-0"6INSIDE CORNER
0'2" 4"8"
SCALE: 3" = 1'-0"
3" = 1'-0"7INSIDE CORNER AT DISSIMILAR SUBSTRATE
3" = 1'-0"8 INSULATED JAMB RETURN
3" = 1'-0"14INSULATED SOFFIT
6" = 1'-0"9OUTSIDE CORNER
3" = 1'-0"10TERMINATION ABOVE GRADE
3" = 1'-0"11TERMINATION ABOVE PAVEMENT
3" = 1'-0"12 TERMINATION AT BALCONY EDGE
6" = 1'-0"13TERMINATION AT HOSE BIBB/ELECTRICAL FIXTURE
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
Revision Schedule
Number Description Date
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216ROOF DETAILS
A-508
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
0'2" 4"8"
SCALE: 3" = 1'-0"
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
REVISION SCHEDULE
# DESCRIPTION DATE
2 ADDENDUM 2 6/21/2024
RESILIENT FLOORING RE:FINISH SCHEDULE
TRANSITION STRIP; REFER TO CARPET SPEC FOR TRANSITION FINISH
CARPET PAD AS SCHEDULED
CARPET AS SCHEDULED
TILE OVER DRY-SET / LATEX-PORTLAND CEMENT THINSET MORTAR
FLUSH BRUSHED STAINLESS STEEL TRANSITION STRIP
RESILIENT FLOORING -FINISHED SURFACE TO BE LEVEL W/ TRANSITION STRIP
WALL COVERING AS SPECIFIED
RUBBER BASE
HEIGHT OF RUBBER BASE AND TILE TO ALIGN
TILE BASE
WALL COVERING AS SPECIFIED
RUBBER BASE
HEIGHT OF RUBBER BASE AND TILE TO ALIGN
TILE BASE
MOISTURE RESISTANT GYPSUM
SHOWER/TUB SURROUND
EDGE OF SHOWER PAN OR TUB
CONTINUOUS SEALANT
TILE BASE
WALL COVERING AS SPECIFIED
0' - 8"0' - 8"0' - 6"
INSTALLATION CLIP BRACKET M FACE MOUNT
3" ROLLER SHADE FASCIA COVER
LIGHTING AS SPECIFIED; TOP OF LIGHT SOURCE TO ALIGN WITH EDGE OF COVE
STAINLESS STEEL CHAIN
SHEER ROLLER SHADE
0' - 10"0' - 6"0' - 6"
CEILING FINISHED TO EXTEND INTO COVE
LIGHTING AS SPECIFIED; TOP OF LIGHT SOURCE TO ALIGN WITH EDGE OF COVE
8" WIDE LAMINATE PLANKS ON Z-CLIPS 0' - 3"1' - 2"0' - 6"0' - 6"
LIGHTING AS SPECIFIEDTOP OF LIGHT SOURCE TO ALIGN WITH EDGE OF COVE
PLASTIC LAMINATE FRAME
0' - 6"0' - 6"0' - 6"LIGHTING AS SPECIFIEDTOP OF LIGHT SOURCE TO ALIGN WITH EDGE OF COVE
ACOUSTIC CEILING
10'-10"AFF0' - 4"8" WIDE LAMINATE PLANKS ON Z-CLIPS
EXTERIOR FINISH
EXTERIOR
INTERIOR0' - 8"0' - 0 3/4"0' - 10"
1/4" REVEAL
FACE OF WALL
WINDOW SYSTEM AS SCHEDULED
PLYWOOD BLOCKING (PAINT TO MATCH CEILING)
OWNER FURNISHED DRAPERY & TRACK
3/4" PAINTED MDF
GUESTROOMGUESTROOM
DOOR AND FRAME BEYOND
FULL SWEEP, TYP. EACH DOOR (AS SPECIFIED)
ADJUSTABLE VINYL THRESHOLD (AS SPECIFIED)
RESILIENT FLOORING
GUESTROOMCORRIDOR
DOOR AND FRAME BEYOND
SWEEP (AS SPECIFIED)
VINYL THRESHOLD(AS SPECIFIED)
CORRIDOR CARPET
RESILIENT FLOORING RE: FINISH SCHEDULE
TRANSITION STRIP; TARKETT, CD-48-C
RESILIENT FLOORING RE: FINISH SCHEDULE
DOOR AND FRAME BEYOND
CARPET AS SCHEDULED
DOOR AND FRAME BEYOND
TILE OVER DRY-SET / LATEX-PORTLAND CEMENT THINSET MORTAR
FLUSH STAINLESS STEEL TRANSITION STRIP
RESILIENT FLOOR COVERING VINYL TO BE LEVEL W/ TRANSITION STRIP
EXTERIOR FINISH
EXTERIOR
INTERIOR0' - 8"0' - 0 3/4"0' - 10"
1/4" REVEAL
FACE OF WALL
WINDOW SYSTEM AS SCHEDULED
PLYWOOD BLOCKING (PAINT TO MATCH CEILING)
OWNER FURNISHED DRAPERY & TRACK
3/4" PAINTED MDF
3" = 1'-0" Reference: 2 / A-411A
1RES TO CARPET TRANSITION
3" = 1'-0" Reference: 2 / A-411A
2RES TO TILE TRANSITION
3" = 1'-0" Reference: 1 / A-423
3TILE TO RUBBER BASE AT WALL END
Efficiency Suite Guest Baths
3" = 1'-0" Reference: 3 / A-423
4 TILE TO RUBBER BASE TRANS AT CORNER
Efficiency Suite Guest Baths
3" = 1'-0" Reference: 1 / A-423
5 TILE TRANSITION AT TUB
Guest Baths
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216TRANSITION,THRESHOLD, & CEILINGDETAILS
A-510
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
1 1/2" = 1'-0" Reference: 1 / A-112
11LIGHT SHADE AT RM PERIMETER
1 1/2" = 1'-0" Reference: 1 / A-112
12LIGHT COVE AT PLASTIC LAMINATE/ACT
1 1/2" = 1'-0" Reference: 1 / A-112
13LIGHT COVE AT NICHE SOFFIT
1 1/2" = 1'-0" Reference: 1 / A-112
14 LIGHT COVE AT GWB/ACT 1 1/2" = 1'-0" Reference: 1 / A-112
15 DETAIL AT PLASTIC LAMINATE/GWB
1 1/2" = 1'-0"16GUESTROOM DRAPERY VALENCE
1" = 1'-0" Reference: 2 / A-411A
7CONNECTOR THRESHOLD
1" = 1'-0" Reference: 1 / A-412A
6ENTRY THRESHOLD
1" = 1'-0" Reference: 2 / A-417A
8CARPET TO RES AT DOOR
1" = 1'-0"9 TILE TO RES AT DOOR
1 1/2" = 1'-0"17WALL-ATTACHED VALENCE
NOT USED
0'2" 4"8"
SCALE: 3" = 1'-0"
0'4" 8"1' 4"
SCALE: 1 1/2" = 1'-0"
0'6" 1'2'
SCALE: 1" = 1'-0"
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
Revision Schedule
Number Description Date
X
Y
RUNNING SLOPE1:20 MAX
RUNNING SLOPE1:12 MAXCOUNTERSLOPE1:20 MAX
WALKCURB RAMPSTREET
NOTE:(1)SLOPE = Y/X WHERE X IS A LEVEL PLANE(2)COUNTERSLOPE SHALL NOT EXCEED 1:20
MEASUREMENT OF CURB RAMP SLOPES
GROUND SURFACESHALL BE SLIP RESISTANT
FLARED SIDES101
X
36" MIN
NOTE:IF X<48", THEN THE SLOPE OF THE FLARED SIDES SHALL NOT EXCEED 1:12
FLARED SIDE
RETURNED CURB
PLANTING OR OTHER NON WALKING SURFACE
BUILT UP TO CURB RAMP
10
136" MI
N
5' - 0"CLEAR3' - 6"PER SLOPE6'-0" MAXPROVIDE HEAVY BROOM FINISH (GRAY CONC.) OR STAMPED PATTERN (COLORED) PER PLAN, PERPENDICULAR TO SLOPE OF RAMP IN AREAS OUTSIDE OF DECTABLE WARNING SURFACE
DETACTABLE WARNING SURFACE - 2'-O" D. x RAMP WIDTH - PROVIDE ONLY WHERE REQUIRED BY LOCAL CODESLANDING
SLOPE CURB DN
1:10 MAX
SLOPE CURB DN
1:10 MAXSLOPE DOWN1:12 MAXCONC CURB
CAST-IN-PLACE DETACTABLE WARNING SYSTEM BY ADA TACTILE SYSTEMS (978-262-9900) OR ARMOR TILE TACTILE SYSTEMS (800-682-2535) COLOR OF DETECTABLE WARNING SHALL BE CONTRASTING COLOR (DARK ON LIGHT CONCRETE OR LIGHT ON DARK CONCRETE/ASPHALT)
SLOPE OF RAMP SURFACE SHALL NOT EXCEED 1:12 - PROVIDE HEAVY BROOM FINISH PERPENDICULAR TO SLOPE OF RAMP
121 MAXWARNING FULL
2'-0" DETACTABLE
WIDTH OF RAMP
0' - 4"12"1'-0" x 2'-0" x .080 REFLECTIVE ALUMINUM SIGN - SEE DETAIL
RESERVE PARKING
1 1/2" X 5/16" LETTERS
6" HIGH x 6 3/4" WIDE ADA SYMBOL
1" x 3/16" LETTERS
GRADE AT LANDSCAPE
1 3/4" x 1 3/4" x 0.105 PERFORATEDGALV STEEL TUBING
2" x 2"x0.105 PERFORATED GALVSTEEL TUBING SET IN CONC. BASE
8" x 5/8" ∅ ANCHOR BARS EACH
WAY THROUGH TUBING
1'-0" ∅ CONCRETE FOOTING (TYP)
1' - 0"2' - 0"5' - 0"2"2' - 0"2"8"5' - 0"5' - 0"PAINT BLUE (TRAFFIC)
PAINT WHITE (FIGURE)
3" WIDE, PAINTWHITE (BORDER)48" MIN - 60" MAXINSTALL ON THE RIGHT SIDE OF DOUBLE DOORS
DOOR - MOUNTED SIGNAGE
CORRESPONDING GRADE 2 BRAILLE
HEIGHT OF LETTERING, 5/8" TO 2" MAX, WITH UPPER CASE CHARACTERS
WALL MOUNTED SIGNAGE TO BE LOCATED ON LATCH SIDE OF DOOR & CLEAR OF DOOR SWING, MOUNT AT 48" MIN. 60" MAX TO CENTERLINE OF SIGN FROM FINISH FLOOR
12"12"12"MEN WOMEN UNISEX RESTROOMS
HANDICAPPEDMEN
ACCESSIBLERESTROOM
TYPICAL WALL SIGNAGE
TYPICAL WALL SIGNAGE
PICTOGRAMS AND/OR LETTERING ARE NOT REQUIRED ON DOOR MOUNTED SIGNAGE
MEN
46" MIN - 60" MAX12"12"APPROVED STAIRWAY IDENTIFICATION SIGNS SHALL BE LOCATED AT EACH FLOOR LEVEL IN ALL ENCLOSED STAIRWAYS IN BUILDING TWO OR MORE STORIES IN HEIGHT. THE SIGN SHALL IDENTIFY THE STAIRWAY, ROOF ACCESS, FLOOR LEVEL AND UPPER & LOWER TERMINUS OF THE STAIRWAY
CORRESPONDING GRADE 2 BRAILLE TO BE LOCATED DIRECTLY UNDER OR ADJACENT TO SIGNAGE INFORMATION
STRAIGHT IN APPROACH48" A.F.F.PARALLEL APPROACH54" TOP OF CABINET1 11/32" x 31/32" THREAD x 5/16" DIA. CORNER BOLT W/ 5/16" SELF LOCKING NUT
ALUM SIGN
GALV STEEL POST, PAINTED
1 9/16" x 1 3/16" THREAD EACHEND x 5/16" DIA. CORNER BOLTW/ (2) 5/16" SELF LOCKING NUT
GALV STEEL POST, PAINTED
DETAIL A
DETAIL B
2"12" MAXNOTE: FOR REFERENCE ONLY MODIFY FOR SELECTED LIFT
LOCATION OF ADA ACCESSIBLE POOL LIFT. PROVIDE ANCHORS OR SLEEVE AS REQUIRED MANUFACTURER. HYDRAULIC UNIT REQUIRES PLUMBING SPIGOT WITHIN WATER BOX. REVISE DETAIL FOR BATTERY POWERED UNIT.
POOL OR SPA EDGE
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216ACCESSIBLE DETAILS
A-511
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
3/8" = 1'-0"1CURB RAMPS
1/4" = 1'-0"2 TYPICAL ADA RAMP
3/4" = 1'-0"3ADA CURB RAMP
3/4" = 1'-0"4ADA PARKING SIGN
3/4" = 1'-0"5ADA PARKING SYMBOL
3/8" = 1'-0"6 RESTROOM SIGNAGE
3/8" = 1'-0"7DOORWAY SIGNAGE
1/2" = 1'-0"8FIRE EXT. MOUNTING HEIGHT
3" = 1'-0"9ADA SIGN DETAILS
3/4" = 1'-0"10 LOW LEVEL EXIT SIGN
1/4" = 1'-0"11 ACCESSIBLE POOL LIFT
0'2" 4"8"
SCALE: 3" = 1'-0"
0'8" 1' 4"2' 8"
SCALE: 3/4" = 1'-0"
0'1' 2'4'
SCALE: 1/2" = 1'-0"
0'1'-4" 2'-8"5''-4"
SCALE: 3/8" = 1'-0"
0'2' 4'8'
SCALE: 1/4" = 1'-0"
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
Revision Schedule
Number Description Date
DECEMBER 09, 2004F RATING-1HRT RATING-3/4HRDRAWING NOT TO SCALE
SYSTEM NO. F-C-2135
NOVEMBER 30, 2004F RATINGS- 1AND 2 HR (SEE ITEM 1)T RATING-0HRL RATING AT AMBIENT - LESS THAN 1 CFM/SQ FTDRAWING NOT TO SCALE
SYSTEM NO. W-L-1158
2
3B
2
3B
1B
1A
1D3B
3A
1C
SECTION A-A
A
AA
A
SECTION A-A
3B
2
1A
3A
1BA
A3B
2
3A
1B
1A
SECTION A-A
APRIL 14, 2004F RATINGS-1 & 2HR (SEE ITEMS 1 AND 2)T RATINGS-0, 1 & 2HR (SEE ITEMS 1 AND 2)DRAWING NOT TO SCALE
SYSTEM NO. W-L-2129
A
A
2
3B 1B 3A
1A
1D3B1C
2
3B
SECTION A-A
DECEMBER 09, 2004F RATING-1HRT RATING-3/4HRDRAWING NOT TO SCALE
SYSTEM NO. F-C-2135
JANUARY 22, 2003HORIZONTAL (FLOOR)RATINGS: CAN/JLC-5115, 1 HOUR F, (FOR T RATINGS SEE ITEM 3)TEST PRESSURE DIFFERENTIAL - 50 PA (0.20" OF WATER) MINIMUMDRAWING NOT TO SCALE
DESIGN NO. TL/PH 60-01
SECTION A-A
6 5 3
2
3
4
3
1 5
MARCH 21, 2005F RATING-2HRT RATINGS-0, J- 3/4 AND 2 HR (SEE ITEM 2)L RATING AT AMBIENT -16 CFM/SQ.FTDRAWING NOT TO SCALE
SYSTEM NO. F-C-3085
A
A2
3B
3B
1B
3A
3B 1D
1A
1C
2
1. FLOOR-CEILING ASSEMBLY - THE FIRE-RATED WOOD JOIST FLOOR-CEILING ASSEMBLY SHALL BE CONSTRUCTED OF THE MATERIAL AND IN THE MANNER SPECIFIED IN THE INDIVIDUAL L500 SERIES FLOOR CEILING DESIGNS IN THE UL FIRE RESISTANCE DIRECTORY, AS SUMMARIZED BELOW:
A. FLOOR SYSTEM - LUMBER OR PLYWOOD SUB-FLOOR WITH FINISH FLOOR OF LUMBER, PLYWOOD OR FLOOR TOPPING MIXTURE AS SPECIFIED IN THE INDIVIDUAL FLOOR-CEILING DESIGN. MAX DIA. OF FLOOR OPENING IS 4 IN. (102MM).
2. THROUGH PENETRANTS - ONE NON METALLIC PIPE TO BE INSTALLED EITHER CONCENTRICALLY OR ECCENTRICALLY WITHIN THE FIRESTOP SYSTEM. PIPE TO BE RIGIDLY SUPPORTED ON BOTH SIDES OF THE FLOOR-CEILING ASSEMBLY. THE SPACE BETWEEN PIPE AND PERIPHERY OF OPENING SHALL BE MIN. 0 IN. (POINT CONTACT) TO MAX 1/2 IN. (13 MM). THE FOLLOWING TYPES AND SIZES OF NONMETALLIC PIPES MAY BE USED.
B. WOOD JOISTS - NOM 2 BY 10 IN. (51 BY 254 MM) LUMBER JOISTS SPACED 16 IN. (406 MM) OC WITH NOM 1 BY 3 IN (25 BY 76 MM) LUMBER BRIDGING AND WITH ENDS FIRESTOPPED. AS AN ALTERNATE TO LUMBER JOISTS, NOM 10 IN. (254 MM) DEEP (OR DEEPER) LUMBER, STEEL OR COMBINATION LUMBER AND STEEL JOISTS, TRUSSES OR STRUCTURAL WOOD MEMBERS WITH BRIDGING AS REQUIRED WITH ENDS FIRESTOPPED.
C. GYPSUM BOARD - NOM 4 FT (122 CM) WIDE BY 5/8" IN. (16MM) THICK AS SPECIFIED IN THE INDIVIDUAL FLOOR-CEILING DESIGN. GYPSUM BOARD NAILED TO WOOD JOISTS MAX DIA. OF CEILING OPENING IS 4 IN. (102 MM).
A. POLYVINYL CHLORIDE (PVC) PIPE - NOM 3 IN. (76 MM) DIA. (OR SMALLER) SCHEDULE 40 SOLID OR CELLULAR CORE PVC PIPE FOR USE IN CLOSED (PROCESS OR SUPPLY) OR VENTED (DRAIN, WASTE OR VENT) PIPING SYSTEMS.
B. ACRYLONITRILE BUTADIENE STYRENE (ABS) PIPE - NOM 3 IN. (76 MM) DIA. (OR SMALLER) SCHEDULE 40 SOLID OR CELLULAR-CORE ABS PIPE FOR USE IN CLOSED (PROCESS OR SUPPLY) OR VENTED (DRAIN, WASTE OR VENT) PIPING SYSTEMS.
3. FIRESTOP SYSTEM - THE FIRESTOP SYSTEM SHALL BE CONSIST OF THE FOLLOWING:
A. PACKING MATERIAL - FOAM BACKER ROD FIRMLY PACKED INTO OPENING IN PLYWOOD FLOOR AS A PERMANENT FORM. PACKING MATERIAL TO BE RECESSED FROM TOP SURFACE OF SUB-FLOOR AS REQUIRED TO ACCOMMODATE THE REQUIRED THICKNESS OF FILL MATERIAL.
B. FILL VOID OR CAVITY MATERIAL - WRAP STRIP NOM 0.13 IN (3.3 MM) THICK BY 2-3/8 IN. (60 MM) WIDE INTUMESCENT WRAP STRIP. THE WRAP STRIP IS CONTINUOUSLY WRAPPED FOUR TIMES AROUND THE OUTER CIRCUMFERENCE OF THE PIPE AT THE UNDERSIDE OF CEILING AND SECURED IN PLACE WITH 1-1/2 IN. (38 MM) WIDE ALUMINUM TAPE IN TREMCO INC TREMSTOP WS.
C. STEEL COLLAR-COLLARS FABRICATED FROM PRECUT MIN. 0.016 IN. (0.4 MM) THICK (NO.28 GAUGE) GALV STEEL AVAILABLE FROM THE FILL MATERIAL MANUFACTURER. COLLAR SHALL BE NOM 2-1/2 IN. (64 MM) DEEP WITH 1 IN. (25MM) WIFE BY 2 IN. (51MM) LONG ANCHOR BOLT ON 2-1/4 IN. (57 MM) CENTERS FOR SECUREMENT TO THE WALL IN ADDITION, THE COLLAR CONTAINS RETAINER TABS, 3/8 TO 3/4 IN.(10 TO 19 MM) WIDE, ON BOTH SIDES OF THE COLLAR FOR RETAINING THE WRAPS STRIPS. THE COLLAR SHALL BE WRAPPED OVER THE WRAP STRIP, OVERLAPPED A MIN. 1 INCH (25MM) AND SECURED TOGETHER USING A MIN OF THREE NO. 6 BY 3/8 IN. ( 10 MM) SELF-DRILLING, SELF-TAPPING STEEL SCREWS OR USING ONE MIN 1/2 IN (13MM) WIDE BY 0.028 IN. (0.7MM) THICK STAINLESS STEEL HOSE CLAMP. THE RETAINING TABS ADJACENT TO THE ANCHOR TABS ARE BENT TOWARD THE PIPE AT ONE OR MORE LOCATIONS TO RETAIN WRAP STRIP. THE RETAINING TABS OPPOSITE THE ANCHOR TABS ARE FOLDED 90 DEGREES TOWARDS THE PIPE TO MAINTAIN THE ANNULAR SPACE AROUND THE PIPE AND TO RETAIN THE WRAP STRIP LAYERS. COLLAR IS SECURED TO THE GYPSUM BOARD SURFACE WITH 1/8 IN. (3MM) DIAM BY 1-1/2 IN. (38MM) DIAM FENDER WASHERS. ANCHORS TO BE USED IN EACH ANCHOR TAB OR AS DESCRIBED IN THE FOLLOWING. TWO ANCHORS, SYMMETRICALLY LOCATED, REQUIRED FOR NOM 1/2 IN. (13MM) TO NOM 2 IN. (51MM) DIAM PIPES. FOUR ANCHORS, SYMMETRICALLY LOCATED, REQUIRED FOR NOM 3 IN. (76MM) TO NOM 4 IN. (102 MM) DIAM PIPES.AS AN ALTERNATE TO (ITEMS 3B AND C) WRAP STRIP/STEEL COLLAR-FIRESTOP DEVICE - THE FIRESTOP DEVICE SHALL BE INSTALLED IN ACCORDANCE WITH THE ACCOMPANYING INSTALLATION INSTRUCTIONS. SEE ITEM 3B ABOVE FOR WRAP STRIPS REQUIRED WITHIN DEVICE. DEVICE WRAPPED AROUND THE PIPE AND SECURED BY USING THE ATTACHED HOSE CLAMP. DEVICE SLID ALONG THE PIPE UNTIL IT ABUTS THE BOTTOM OF THE CEILING. ANCHOR BOLTS TO BE USED WITH EVERY OTHER ANCHOR TAB WITH A MIN. OF TWO. DEVICE SECURED TO CEILING WITH MIN 1/8 IN. (3MM) DIAM BY 1-1/2 IN. (38MM) DIAM STEEL FENDER WASHERS. TREMCO INC- TREMSTOP -DD. FILL, VOID OR CAVITY MATERIAL - CAULK - MIN 1/2IN. (13MM) THICKNESS OF FILL MATERIAL APPLIED WITHIN THE ANNULUS, FLUSH WITH TOP SURFACE OF SUBFLOOR. ADDITIONAL FILL MATERIAL TO BE INSTALLED SUCH THAT A MIN 1/2 IN. (13MM) CROWN IS FORMED AROUND THE PIPE/SUBFLOOR. PIPE/COLLAR AND COLLAR/GYPSUM BOARD INTERFACES AND LAPPING 3/4I IN. (19MM) BEYOND THE PERIPHERY OF THE OPENING. THE TYPE OF FILL MATERIAL USED IS DEPENDENT ON THE SIZE OF NONMETALLIC PIPE (ITEM 2). FOR PIPES OF 2 IN. (51MM) DIAM OR SMALLER, ANY OF THE FILL MATERIALS INDICATED BELOW CAN BE USED. FIR PIPE DIAMS GREATER THAN 2 IN. (51MM), ONLY THE TREMSTOP INTUMESCENT ACRYLIC MAY BE USED.TREMCO INC. - TREMSTOP INTUMESCENT ACRYLIC, TREMSTOP ACRYLIC OR FYRE-SIL BEARING THE UL CLASSIFICATION MARK.
WALL ASSEMBLY - THE 1 OR 2 HOUR FIRE - RATED GYPSUM BOARD STUD WALL ASSEMBLY SHALL BE CONSTRUCTED OF THE MATERIALS AND IN THE MANNER SPECIFIED IN THE INDIVIDUAL U300, U400 OR V400 SERIES WALL AND PARTITION DESIGNS IN THE UL FIRE RESISTANCE DIRECTORY AND SHALL INCLUDE THE FOLLOWING CONSTRUCTION FEATURES:
A. STUDS - WALL FRAMING MAY CONSIST OF EITHER WOOD STUDS OR STEEL CHANNEL STUDS. WOOD STUDS TO CONSIST OF NOM 2 BY 4 IN. (51 BY 102 MM) LUMBER SPACED 16 IN. (406 MM) STEEL STUDS TO BE MIN 2-1/2 IN. (64 MM) WIDE AND SPACED MAX 24 IN. (610 MM) OC.
B. GYPSUM BOARD - ONE OR TWO LAYERS OF NOM 1/2 OR 5/8 IN. (13 OR 16 MM) THICK GYPSUM BOARD AS SPECIFIED IN THE INDIVIDUAL WALL AND PARTITION DESIGN. MAX DIAM OF OPENING IS 15-1/8 IN. (384 MM).
THE HOURLY F RATING OF THE FIRESTOP SYSTEM IS EQUAL TO THE HOURLY FIRE RATING OF THE WALL ASSEMBLY IN WHICH IT IS INSTALLED.STEEL SLEEVE - (OPTIONAL. NOT SHOWN.) CYLINDRICAL SLEEVE FABRICATED FROM MIN 0.013 IN. (0.330 MM) THICK (NO. 30 GAUGE) TO MAX 0.056 IN. (1.42 MM) (NO. 16 GAUGE) GALV STEEL SHEET AND HAVING A MIN. 1 IN. (25MM) LAP ALONG THE LONGITUDINAL SEAM. ENDS OF SLEEVE TO BE TRIMMED FLUSH WITH BOTH SURFACES OF WALL. SLEEVE TO BE INSTALLED BY COILING THE SHEET METAL TO A DIAM SMALLER THAN THE THROUGH OPENING, INSERTING THE COIL THROUGH THE OPENING AND RELEASING THE COIL TO LET IT UNCOIL AGAINST THE CIRCULAR CUTOUTS IN THE GYPSUM BOARD LAYERS.THROUGH PENETRANTS - ONE METALLIC PIPE, TUBING OR CONDUIT TO BE INSTALLED EITHER CONCENTRICALLY OR ECCENTRICALLY WITHIN THE FIRESTOP SYSTEM. PIPE, TUBING OR CONDUIT TO BE RIGIDLY SUPPORTED ON BOTH SIDES OF WALL ASSEMBLY AND SHALL BE PROVIDED WITH FLEXIBLE COUPLINGS WITHIN 1 FT. OF EACH SIDE OF WALL. THE PIPE, TUBING OR CONDUIT MAY BE INSTALLED AT AN ANGLE NOT GREATER THAN 45 DEGREES FROM THE PERPENDICULAR. THE ANNULAR SPACE SHALL BE MIN 0 (POINT CONTACT) IN. TO MAX 1-7/8 IN. (48 MM). THE FOLLOWING TYPES AND SIZES OF METALLIC PIPE TUBING OR CONDUIT MAY BE USED:
A. STEEL PIPE - NOM 12 IN. (305 MM) DIAM (OR SMALLER) SCHEDULE 10 (OR HEAVIER) STEEL PIPE.
B. IRON PIPE - NOM 12 IN. (305 MM) DIAM (OR SMALLER) CAST OR DUCTILE IRON PIPE.
C. CONDUIT - NOM 4 IN. (102 MM) DIAM (OR SMALLER) STEEL ELECTRICAL METALLIC TUBING OR NOM 6 IN. DIAM (OR SMALLER) STEEL CONDUIT.
D. COPPER TUBING - NOM 4 IN. (102 MM) DIAM (OR SMALLER) TYPE L (OR HEAVIER) COPPER TUBING.
E. COPPER PIPE - NOM 4 IN. (102MM) DIAM (OR SMALLER) REGULAR (OR HEAVIER) COPPER PIPE.
FIRESTOP SYSTEM - THE FIRESTOP SYSTEM SHALL CONSIST OF THE FOLLOWING:
A. PACKAGING MATERIAL - (OPTIONAL) - FOAM BACKER ROD FIRMLY PACKED INTO THE OPENING A SA PERMANENT FORM. PACKING MATERIAL TO BE RECESSED FROM BOTH SURFACES OF WALL AS REQUIRED TO ACCOMMODATE THE REQUIRED THICKNESS OF FILL MATERIAL.
B. FILL, VOID OR CAVITY MATERIAL - (CAULK) MIN 1/2 IN. (13MM). THE SURFACES OF WALL. WHEN ANNULAR SPACE EXCEEDS 1/2 IN. (13MM). THE MIN. THICKNESS OF FILL MATERIAL IS 5/8 IN. (16MM). ADDITIONAL FILL MATERIAL TO BE INSTALLED SUCH THAT A MIN 3/8 IN. (10MM) CROWN IS APPLIED AT THE PIPE/WALL INTERFACE AT THE POINT CONTACT LOCATION.
TREMCO INC. - TREMSTOP INTUMESCENT ACRYLICBEARING THE UL CLASSIFICATION MARK
1. WALL ASSEMBLY - THE 1 OR 2 HR FIRE-RATED GYPSUM BOARD / STUD WALL ASSEMBLY SHALL BE CONSTRUCTED OF THE MATERIALS AND IN THE MANNER SPECIFIED IN THE INDIVIDUAL U300, U400 OR V400 SERIES WALL AND PARTITION DESIGNS IN THE UL FIRE RESISTANCE DIRECTORY AND SHALL INCLUDE THE FOLLOWING CONSTRUCTION FEATURES:
A. STUDS - WALL FRAMING MAY CONSIST OF EITHER WOOD STUDS OR STEEL CHANNEL STUDS. WOOD STUDS TO CONSIST OF NOM 2 BY 4 IN. (51 BY 102 MM) LUMBER SPACED 16IN. (406 MM) OC. STEEL STUDS TO BE MIN 2-1/2 IN. (64MM) WIDE AND SPACED MAX 24 IN. (610 MM) OC.
B. GYPSUM BOARD - 5/8 IN. (16MM) THICK, 4 FT (122 CM) WIDE WITH SQUARE OR TAPERED EDGES. THE GYPSUM BOARD TYPE, THICKNESS, NUMBER OF LAYERS, FASTENER TYPE AND SHEET ORIENTATION SHALL BE AS SPECIFIED IN THE INDIVIDUAL WALL AND PARTITION DESIGN. MAX DIAM OF OPENING IS 4 IN. (102MM).THE HOURLY F & T RATINGS OF THE FIRESTOP SYSTEM ARE EQUAL TO THE HOURLY FIRE RATING OF THE WALL ASSEMBLY IN WHICH IT IS INSTALLED UNLESS NOTED OTHERWISE.
2. THROUGH PENETRANTS - ONE NONMETALLIC PIPE TO BE INSTALLED EITHER CONCENTRICALLY OR ECCENTRICALLY WITHIN THE FIRESTOP SYSTEM. PIPE TO BE RIGIDLY SUPPORTED ON BOTH SIDES OF WALL ASSEMBLY AND SHALL BE PROVIDED WITH FLEXIBLE COUPLINGS WITHIN 1 FT. OF EACH SIDE OF WALL. THE FOLLOWING TYPES AND SIZES OF NONMETALLIC PIPES MAY BE USED:
A. POLYVINYL CHLORIDE (PVC) PIPE - NOM 2 IN. (51 MM) DIAM (OR SMALLER) SCHEDULE 40 SOLID CORE PVC PIPE FOR USE IN CLOSED (PROCESS OR SUPPLY) OR VENTED (DRAIN, WASTE OR VENT) PIPING SYSTEMS. THE ANNULAR SPACE BETWEEN PIPE AND PERIPHERY OF OPENING SHALL BE MIN 9 IN. (POINT CONTACT) TO MAX 7/8 IN. (22 MM). FOR USE WITH 1 HR WALL CONSTRUCTIONS ONLY. WHEN USED, F RATING IS 1 HR AND T RATING IS 0 HR.
B. POLYVINYL CHLORIDE (PVC) PIPE - NOM 2 IN. (51 MM) DIAM (OR SMALLER) SCHEDULE 40 SOLID CORE PVC PIPE FOR USE IN CLOSED (PROCESS OR SUPPLY) PIPING SYSTEMS. THE ANNULAR SPACE BETWEEN PIPE AND PERIPHERY OPENING SHALL BE MIN 1/4 IN. 6 MM) TO MAX 1-3/8 IN. (35MM).
C. CHLORINATED POLYVINYL CHLORIDE (CPVC) PIPE - NOM 2 IN. (51 MM) DIAM (OR SMALLER) SDR 13.5 CPVC PIPE FOR USE IN CLOSED (PROCESS OR SUPPLY) PIPING SYSTEMS. THE ANNULAR SPACE BETWEEN PIPE AND PERIPHERY OF OPENING SHALL BE MIN 1/4 IN. (6MM) TO MAX 1-3/8 IN. (35 MM).
D. ACRYLONITRILE BUTADIENE STYRENE (ABS) PIPE - NOM 2 IN. (51 MM) DIAM (OR SMALLER) SCHEDULE 40 SOLID-CORE ABS PIPE FOR USE IN CLOSED (PROCESS OR SUPPLY) OR VENTED (DRAIN, WASTE OR VENT) PIPING SYSTEMS. THE ANNULAR SPACE BETWEEN PIPE NAD PERIPHERY OF OPENING SHALL BE MIN 1/4 IN. (6 MM) TO MAX 7/8 IN. (22 MM).
E. CROSSLINKED POLYETHYLENE (PEX) TUBE - NOM 1 IN. (25 MM) DIAM (OR SMALLER) SDR 9 PEX TUBING FOR USE IN CLOSED (PROCESS OR SUPPLY) PIPING SYSTEMS. THE ANNULAR SPACE BETWEEN TUBE AND PERIPHERY OF OPENING SHALL BE MIN 1/4 IN. (6 MM) TO MAX 1-3/8 IN. (35 MM).
F. RIGID NONMETALLIC CONDUIT + - NOM 2 IN. (51 MM) DIAM (OR SMALLER)M SCHEDULE 40 PVC CONDUIT INSTALLED IN ACCORDANCE WITH ARTICLE 347 OF THE NATIONAL ELECTRICAL CODE (NFPA NO. 70). THE ANNULAR SPACE BETWEEN CONDUIT AND PERIPHERY OF OPENING SHALL BE MIN 1/4 IN. (6 MM) TO MAX 1-3/8 IN. (35 MM).
G. CHLORINATED POLYVINYL CHLORIDE (CPVC) PIPE - NOM 2IN. DIAM (OP SMALLER) FLOWGUARD GOLD SDR 11 CPVC FOR USE IN CLOSED (PROCESS OR SUPPLY) PIPING SYSTEMS. THE ANNULAR SPACE BETWEEN CONDUIT AND PERIPHERY OF OPENING SHALL BE MIN 1/4 IN. (6 MM) TO MAX 1-3/8 IN. (35 MM)
H. CHLORINATED POLYVINYL (CPVC) PIPE - NOM 2 IN. DIAM (OR SMALLER) BLAZEMASTER SDR 13.5 CPVC FOR USE IN CLOSED (PROCESS OR SUPPLY) PIPING SYSTEMS. THE ANNULAR SPACE BETWEEN CONDUIT AND PERIPHERY OF OPENING SHALL BE MIN 1/4 IN. (6 MM) TO MAX 1-3/8 IN. (35 MM).
3. FIRESTOP SYSYTEM - THE FIRESTOP SYSTEM SHALL CONSIST OF THE FOLLOWING:
A. PACKING MATERIAL - (OPTIONAL) IN 2HR WALL ASSEMBLIES, FOAM BACKER ROD FIRMLY PACKED INTO OPENING AS A PERMANENT FORM. PACKING MATERIAL TO BE PROCESSED FROM BOTH SURFACES OF WALL AS REQUIRED TO ACCOMMODATE THE REQUIRED THICKNESS OF FILL MATERIAL.
B. FILL, VOID OR CAVITY MATERIAL - CAULK - MIN 5/8 IN. (16 MM) THICKNESS OF FILL MATERIAL APPLIED WITHIN THE ANNULUS, FLUSH WITH BOTH SURFACES OF WALL. ADDITIONAL FILL MATERIAL TO BE INSTALLED SUCH THAT A MIN 1/4 IN. (6 MM) CROWN IS FORMED AROUND THE PENETRATING ITEM.
TREMCO INC. - TREMSTOP INTUMESCENT ACRYLICBEARING THE UL CLASSIFICATION MARK
1. FLOOR - CEILING ASSEMBLY - THE FIRE-RATED WOOD JOIST FLOOR - CEILING ASSEMBLY SHALL BE CONSTRUCTED OF THE MATERIALS AND IN THE MANNER SPECIFIED IN THE INDIVIDUAL L500 SERIES FLOOR-CEILING DESIGNS IN THE UL FIRE RESISTANCE DIRECTORY, AS SUMMARIZED BELOW:
A. FLOORING SYSTEM - LUMBER OR PLYWOOD SUBFLOOR WITH FINISH FLOOR OF LUMBER, PLYWOOD OR FLOOR TOPPING MIXTURE AS SPECIFIED IN THE INDIVIDUAL FLOOR-CEILING DESIGN. MAX DIAM OF FLOOR OPENING IS 4 IN. (102 MM).
B. WOOD JOISTS - NOM 2 BY 10 IN. (51 BY 254 MM) LUMBER JOISTS SPACED 16 IN. (406 MM) OC WITH NOM 1 BY 3 IN. (25 BY 76 MM) LUMBER BRIDGING AND WITH ENDS FIRESTOPPED. AS AN ALTERNATE TO LUMBER JOISTS, NOM 10 IN. (254 MM) DEEP (OR DEEPER) LUMBER, STEEL OR COMBINATION LUMBER AND STEEL JOISTS, TRUSSES OR STRUCTURAL WOOD MEMBERS WITH BRIDGING AS REQUIRED WITH ENDS FIRESTOPPED.
C. GYPSUM BOARD - NOM 4 FT (122 CM) WIDE BY 5/8 IN. (16 MM) THICK AS SPECIFIED IN THE INDIVIDUAL FLOOR-CEILING DESIGN. GYPSUM BOARD NAILED TO WOOD JOISTS. MAX DIAM OF CEILING OPENING IS 4 IN. (102 MM).
2. THROUGH PENETRANTS - ONE NONMETALLIC PIPE TO BE INSTALLED EITHER CONCENTRICALLY OR ECCENTRICALLY WITHIN THE FIRESTOP SYSTEM. PIPE TO BE RIGIDLY SUPPORTED ON BOTH SIDES OF FLOOR-CEILING ASSEMBLY. THE SPACE BETWEEN PIPE AND PERIPHERY OF OPENING SHALL BE MIN O IN. (POINT CONTACT) TO MAX 1/2 IN. (13 MM). THE FOLLOWING TYPES AND SIZES OF NONMETALLIC PIPES MAY BE USED:
A. POLYVINYL CHLORIDE (PVC) PIPE - NOM 3 IN. (76 MM) DIAM (OR SMALLER) SCHEDULE 40 SOLID OR CELLULAR-CORE PVC PIPE FOR USE IN CLOSED (PROCESS OR SUPPLY) OR VENTED (DRAIN, WASTE OR VENT) PIPING SYSTEMS.
B. ACRYLONITRILE BUTADIENE STYRENE (ABS) PIPE - NOM 3 IN. (76 MM) DIAM (OR SMALLER) SCHEDULE 40 SOILD OR CELLULAR-CORE ABS PIPE FOR USE IN CLOSED (PROCESS OR SUPPLY) OR VENTED (DRAIN, WASTE R VENT) PIPING SYSTEMS.
3. FIRESTOP SYSTEM - THE FIRESTOP SYSTEM SHALL CONSIST OF THE FOLLOWING:
A. PACKING MATERIAL - FOAM BACKER ROD FIRMLY PACKED INTO OPENING IN PLYWOOD FLOOR AS A PERMANENT FORM. PACKING MATERIAL TO BE RECESSED FROM TOP SURFACE OF SUBFLOOR AS REQUIRED TO ACCOMMODATE THE REQUIRED THICKNESS OF FILL MATERIAL.
B. FILL, VOID OR CAVITY MATERIAL -WRAP STRIP - NOM 0.13 IN. (3.3 MM) THICK BY 2-3/8 IN. (60 MM) WIDE INTUMESCENT WRAP STRIP. THE WRAP STRIP IS CONTINUOUSLY WRAPPED FOUR TIMES AROUND THE OUTER CIRCUMFERENCE OF THE PIPE AT THE UNDERSIDE OF CEILING AND SECURED IN PLACE WITH 1-1/2 IN. (38 MM) WIDE ALUMINUM TAPE.TREMCO INC - TREMSTOP -WS
C. STEEL COLLAR - COLLARS FABRICATED FROM PRECUT MIN 0.016 IN. (0.4 MM) THICK (NO.28 GAUGE) GALV STEEL AVAILABLE FROM THE FILL MATERIAL MANUFACTURER. COLLAR SHALL BE NOM. 2-1/2 IN. (64 MM) DEEP WITH 1 IN. (25 MM) WIDE BY 2 IN. (51 MM) LONG ANCHOR TABS ON 2-1/4 IN. (57 MM) CENTERS FOR SECUREMENT TO THE WALL. IN ADDITION, THE COLLAR CONTAINS RETAINER TABS. 3/8 TO 3/4 IN. (10 TO 19 MM) WIDE, ON BOTH SIDES OF THE COLLAR FOR RETAINING THE WRAP STRIPS. THE COLLAR SHALL BE WRAPPED OVER THE WRAP STRIP, OVERLAPPED A MIN 1 IN. (25 MM) AND SECURED TOGETHER USING A MIN OF THREE NO. 6 BY 3/8 IN. (10 MM) SELF-DRILLING, SELF TAPPING STEEL SCREWS OR USING ONE MIN 1/2 IN. (13 MM) WIDE BY 0.028 IN. (0.7 MM) THICK STAINLESS STEEL HOSE CLAMP. THE RETAINING TABS ADJACENT TO THE ANCHOR TABS ARE BENT TOWARD THE PIPE TO MAINTAIN THE ANNULAR SPACE AROUND THE PIPE AND TO RETAIN THE WRAP STRIP LAYERS. COLLAR IS SECURED TO THE GYPSUM BOARD SURFACE WITH 1/8 IN. (3 MM) DIAM BY 1-1/2 IN. (38 MM) LONG HOLLOW WALL ANCHORS IN CONJUNCTION WITH MIN 1-1/2 IN. (38 MM) DIAM FENDER WASHERS. ANCHORS TO BE USED IN EACH ANCHOR TAB OR AS DESCRIBED IN THE FOLLOWING. TWO ANCHORS, SYMMETRICALLY LOCATED, REQUIRED FRO NOM 1/2 IN. (13 MM) TO NOM 2 IN. (51 MM) DIAM PIPES. FOUR ANCHORS, SYMMETRICALLY LOCATED, REQUIRED FOR NOM 3 IN. (76 MM) TO NOM 4 IN. (102 MM) DIAM PIPES.AS AN ALTERNATE TO (ITEMS 3B AND C) WRAP STRIP/STEEL COLLAR-FIRESTOP DEVICE - THE FIRESTOP DEVICE SHALL BE INSTALLED IN ACCORDANCE WITH THE ACCOMPANYING INSTALLATION INSTRUCTIONS. SEE ITEM 3B ABOVE FOR WRAP STRIPS REQUIRED WITHIN DEVICE. DEVICE WRAPPED AROUND THE PIPE AND SECURED BY USING THE ATTACHED HOSE CLAMP. DEVICE SLID ALONG THE PIPE UNTIL IT ABUTS THE BOTTOM OF THE CEILING. ANCHOR BOLTS TO BE USED WITH EVERY OTHER ANCHOR TAB WITH A MIN OF TWO. DEVICE SECURED TO CEILING WITH A MIN 1/8 IN. (3 MM) DIAM BY 1-1/2 IN. (38 MM) DIAM STEEL FENDER WASHERS.TREMCO INC - TREMSTOP - D
D. FILL, VOID OR CAVITY MATERIAL - CAULK - MIN 1/2 IN. (13 MM) THICKNESS OF ILL MATERIAL APPLIED WITHIN THE ANNULUS, FLUSH WITH TOP SURFACE OF SUBFLOOR. ADDITIONAL FILL MATERIAL TO BE INSTALLED SUCH THAT A MIN 1/2 IN. (13 MM) CROWN IS FORMED AROUND THE PIPE/SUBFLOOR. PIPE/COLLAR AND COLLAR/GYPSUM BOARD INTERFACES AND LAPPING 3/4 IN. (19 MM) BEYOND THE PERIPHERY OF THE OPENING. THE TYPE OF FILL MATERIAL USED IS DEPENDENT ON THE SIZE OF NON METALLIC PIPE (ITEM 2). INDICATED BELOW CAN BE USED. FOR PIPE DIAM GREATER THAN 2 IN. (51 MM) ONLY THE TREMSTOP INTUMESCENT ACRYLIC MAY BE USED.TREMSTOP INC - TREMSTOP INTUMESCENT ACRYLIC. TREMSTOP ACRYLIC OR FYRE-SIL BEARING THE UL CLASSIFICATION MARK
PENETRATIONS IN A WALL
MAX. 2" PVC & CPVC SCH 40MAX. 11/2" PVC & CPVC SCH 40MAX. 1' PEXELECTRICAL WIRES (5)4" STEEL OR CAST IRON
MAX. OPENING SIZE
4"3"2"1 1/2"51/2" x 6"
THROUGH-PENETRATIONS
1 PEXELECTRICAL WIRES 2" COPPER1 1/2' EMT1 1/2" COPPER
MAX OPENING SIZE
2"21/4" 3" x 33"3"
1. FLOOR - 1 HOUR RATED FLOOR/CEILING ASSEMBLY FRAMED WITH NOMINAL 2" x 10" JOISTS.
2. WALL - RATED OR NONRATED WALL ASSEMBLY FRAMED WITH NOMINAL 2" X 4" WOOD/STEEL STUDS FACED WITH GYPSUM WALLBOARD.
3. PENETRATING ITEMS - SEE TABLE ABOVE. T RATING FOR NON METALLIC PENETRATIONS - 1 HOUR, EXCEPT CPVC - T RATING 45 MINUTES. T RATING FOR METALLIC PENETRATIONS - 60 MINUTES. ELECTRICAL BUNDLE CONSISTS OF TO 5 LOOMEX 1 4/2 WIRES OR 4 LOOMEX 14/2 WIRES AND A 1" DIAMETER TEK CABLE.
4. FIRE STOP CAULK - TREMCO FYRE-SIL APPLIED TO A DEPTH OF 5/8" WHERE PENETRATION PASSES THROUGH FLOOR OR CEILING MEMBRANE, OR THROUGH HEADER OR SOLE PLATES OF WALL ASSEMBLY.
5. FIRESTOP CAULK - TREMCO FYRE-SIL APPLIED TO A DEPTH OF 5/8" WHERE PENETRATION PASSES THROUGH FLOOR OR CEILING MEMBRANE, OR THROUGH HEADER OR SOLE PLATES OF WALL ASSEMBLY.
6. GYPSUM WALLBOARD - SEAL FOR 10" X 10" OPENING, 5/8" TYPE X SCREWED TO UNDERSIDE OF PLYWOOD. MAXIMUM 2-1/2" HOLE. ANNULAR SPACE AROUND PIPE SEALED WITH FYRE-SILT DEPTH OF THE MEMBRANE.
1. FLOOR - CEILING ASSEMBLY - THE 2 HR FIRE-RATED WOOD JOIST FLOOR-CEILING ASSEMBLY SHALL BE CONSTRUCTED OF THE MATERIALS AND IN THE MANNER SPECIFIED IN DESIGN NOS. L505, L511 OR L536 IN THE UL FIRE RESISTANCE DIRECTORY. THE GENERAL CONSTRUCTION FEATURES OF THE FLOOR-CEILING ASSEMBLY ARE SUMMARIZED BELOW:
A. WOOD JOISTS - NOM 2 BY 10 IN. (51 BY 254 MM) LUMBER JOISTS SPACED 16 IN. (406 MM) OC WITH NOM 1 BY 3 IN. (25 BY 76 MM) LUMBER BRIDGING AND WITH ENDS FIRESTOPPED.
B. FLOORING SYSTEM - LUMBER OR PLYWOOD SUBFLOOR WITH FINISH FLOOR OF LUMBER, PLYWOOD OR FLOOR TOPPING MIXTURE AS SPECIFIED IN THE INDIVIDUAL FLOOR-CEILING DESIGN. MAX DIAM OF FLOOR OPENING IS 3 IN. (76 MM).
C. FURRING CHANNELS - RESILIENT GALV STEEL FURRING CHANNELS INSTALLED PERPENDICULAR TO WOOD JOISTS BETWEEN FIRST AND SECOND LAYERS OF GYPSUM BOARD (ITEM ID). FURRING CHANNELS SPACED MAX 24 IN. (610 MM) OC.
D. GYPSUM BOARD - NOM 4 FT (122 CM) WIDE BY 5/8 IN. (16 MM) THICK AS SPECIFIED IN THE INDIVIDUAL FLOOR-CEILING DESIGN. SECOND LAYER OF GYPSUM BOARD SCREW-ATTACHED TO FURRING CHANNELS AS SPECIFIED IN THE INDIVIDUAL FLOOR-CEILING DESIGN. MAX DIAM OF CEILING OPENING IS 3 IN. (76 MM)
1.1 CHASE WALL - (NOT SHOWN, OPTIONAL) THE THROUGH PENETRANT (ITEM 2) MAY BE ROUTED THROUGH A 2 HR FIRE RATED SINGLE, DOUBLE OR STAGGERED WOOD STUD/ GYPSUM WALLBOARD CHASE WALL CONSTRUCTED OF THE MATERIALS AND IN THE MANNER SPECIFIED IN THE INDIVIDUAL U300 SERIES WALL AND PARTITION DESIGNS IN THE UL FIRE RESISTANCE DIRECTORY AND SHALL INCLUDE THE FOLLOWING CONSTRUCTION FEATURES:
A. STUDS - NOM 2 BY 6 IN. (51 BY 152 MM) LUMBER STUDS.
B. SOLE PLATE - NOM 2 BY 6 IN. (51 BY 152 MM) LUMBER PLATES. MAX DIAM OF OPENING IS 3 IN. (76 MM).
C. TOP PLATE - THE DOUBLE TOP PLATE SHALL CONSIST OF TWO NOM 2 BY 6 IN. (51 BY 152 MM) LUMBER PLATES. MAX DIAM OF OPENING IS 3 IN. (76 MM).
D. GYPSUM BOARD - THICKNESS, TYPE, NUMBER OF LAYERS AND FASTENERS SHALL BE AS SPECIFIED IN INDIVIDUAL WALL AND PARTITION DESIGN.
2. CABLES - AGGREGATE CROSS-SECTIONAL AREA OF CABLES IN OPENING TO BE MAX 44 PERCENT OF THE AGGREGATE CROSS SECTIONAL AREA OF THE OPENING. THE ANNULAR SPACE BETWEEN THE CABLE BUNDLE AND THE PERIPHERY OF THE OPENING SHALL BE MIN 1/4 IN. (6 MM) TO MAX 1/2 IN. (13 MM). CABLES TO BE RIGIDLY SUPPORTED ON BOTH SIDES OF FLOOR ASSEMBLY, ANY COMBINATION OF THE FOLLOWING TYPES AND SIZES OF COPPER CONDUCTOR CABLES MAY BE USED:
A. MAX 200 PAIR NO. 24 AWG (OR SMALLER) COPPER CONDUCTOR CABLE WITH POLYVINYL CHLORIDE (PVC) INSULATION AND JACKET.
B. RG59/U (OR SMALLER) COAXIAL CABLE WITH FLUORINATED ETHYLENE (FE) OR PVC INSULATION AND JACKET.
C. MAX 4 PAIR NO. 24 AWG (OR SMALLER) COPPER CONDUCTOR DATA CABLE WITH HYLAR JACKET AND INSULATION.
D. MAX THREE CONDUCTOR WITH GROUND NO. 12 AWG (OR SMALLER) NONMETALLIC SHEATHED (ROMEX) CABLES WITH PVC INSULATION AND JACKET MATERIALS.
E. THROUGH PENETRATING PRODUCT - TWO OR MORE TWISTED COPPER CONDUCTORS N0. 10 AWG (OR SMALLER) POWER LIMITED FIRE ALARM CABLE + WITHOUT A JACKET UNDERA METAL ARMOR.AFC CABLE SYSTEMS INC
F. THROUGH PENETRATING PRODUCT - TWO OR MORE TWISTED COPPER CONDUCTORS NO. 12 AWG (OR SMALLER) NON POWER LIMITED FIRE ALARM CABLE + WITH OR WITHOUT A JACKET UNDER A METAL ARMOR.AFC CABLE SYSTEMS INC.
G. THROUGH PENETRATING PRODUCT - MAX TWO COPPER CONDUCTORS WITH GROUND NO. 12 AWG (OR SMALLER) METAL-CLAD CABLE+.AFC CABLE SYSTEMS INC.
H. THROUGH PENETRATING PRODUCT - NOM 3/4 IN. (19MM) DIAM (OR SMALLER) ALUMINUM OR STEEL FLEXIBLE METAL CONDUIT + WITH ELECTRICAL CONDUCTORS AS PERMITTED BY THE NATIONAL ELECTRICAL CODE (NFPA 70).AFLEX CORP
I. MAX FOUR ALUMINUM CONDUCTOR NO 2/0 AWG (OR SMALLER) TYPE SER SERVICE ENTRANCE CABLE WITH CROSS-LINKED POLYETHYLENE INSULATION AND PVC JACKET.THE T RATING IS 2 HR EXCEPT THAT THE T RATING FOR ITEM A IS 1-3/4 HR AND THE T RATING FOR ITEMS H AND I IS O HR.
3. FIRESTOP SYSTEM - THE FIRESTOP SYSTEM CONSISTS OF THE FOLLOWING ITEMS:
A. PACKING MATERIAL - (OPTIONAL) FOAM BACKER ROD FIRMLY PACKED INTO OPENING AS A PERMANENT FORM AND RECESSED FROM TOP SURFACE OF FLOOR OR SOLE PLATE AND BOTTOM SURFACE OF CEILING OR LOWER TOP PLATE OF CHASE WALL ASSEMBLY TO ACCOMMODATE REQUIRED THICKNESS OF FILL MATERIAL.
B. FILL, VOID OR CAVITY MATERIAL - CAULK - MIN 5/8 IN. (16 MM) THICKNESS OF FILL MATERIAL APPLIED WITHIN THE ANNULUS, FLUSH WITH TOP SURFACE OF THE FLOOR OR SOLE PLATE AND BOTTOM SURFACE OF THE CEILING OR LOWER TOP PLATE OF CHASE WALL ASSEMBLY. ADDITIONAL FILL MATERIAL TO BE FORCED INTO INTERSTICES OF CABLE GROUP TO MAX EXTENT POSSIBLE CROWN IS FORMED AROUND THE CABLE GROUP AND LAPPING 1/2 IN. (13 MM) BEYOND THE PERIPHERY OF THE OPENING.TREMCO INC - TREMSTOP INTUMESCENT ACRYLICBEARING THE UL CLASSIFICATION MARK+ BEARING THE UL LISTING MARK
FIRE PENETRATION DETAILS
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216FIRE PENETRATIONDETAILS
A-512
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
Revision Schedule
Number Description Date
INTERIOREXTERIOR
5/8" EXTERIOR GWB (DENSGLAS OR SIMILAR)
VAPOR BARRIER
XE1 - EIFS FINISH: NO SHEAR
2" EIFS SYSTEM
LAYER TYPE X 5/8" GYPSUM WALL BD.
FLOOR AND BASE FIN. AS SCHEDULE
AIR BARRIER
2" X 6" WOOD STUD, 16" O.C, FILLED WITH FIBERGLASS BATT INSULATION
COLORS A-E: SEE GRAPHIC LEGENDCODE MIN R-VALUE: R:20 STD + R3.8 CIR-VALUE: R-20 STUD + R-8.6 CIUL DESIGN: U349FIRE RATING: 2 HOURS FROM EXTERIOR, 1 HOUR FROM INTERIORSTC RATING: 50 (EXTRAPOLATED)STC TEST: NGC 2015085HEIGHT: CONTINUOUS
FOUNDATION
INTERIOREXTERIOR
5/8" FIRE-RATED PLYWOOD SHEATHING PER STRUCTURAL
VAPOR BARRIER
XE2 - EIFS FINISH: SINGLE SHEAR
2" EIFS SYSTEM
FLOOR AND BASE FIN. AS SCHEDULE
AIR BARRIER
2" X 6" WOOD STUD, 16" O.C, FILLED WITH FIBERGLASS BATT INSULATION
COLORS A-E: SEE GRAPHIC LEGENDCODE MIN R-VALUE: R:20 STD + R3.8 CIR-VALUE: R-20 STUD + R-8.8 CIUL DESIGN: U349FIRE RATING: 2 HOURS FROM EXTERIOR, 1 HOUR FROM INTERIORSTC RATING: 50 (EXTRAPOLATED)STC TEST: NGC 2015085HEIGHT: CONTINUOUSMIN.0' - 6"FOUNDATION
/10 A-509/11 A-509
MIN.0' - 2"PAVEMENT
/3 A-509SIM
INTERIOR EXTERIOR
5/8" FIRE-RATED PLYWOOD SHEATHING PER STRUCTURAL EITHER SIDE
VAPOR BARRIER
XE3 - EIFS FINISH: DOUBLE SHEAR
2" EIFS SYSTEMLAYER TYPE X 5/8" ACOUSTIC GYPSUM WALL BD.
FLOOR AND BASE FIN. AS SCHEDULE
AIR BARRIER
2" X 6" WOOD STUD, 16" O.C, FILLED WITH FIBERGLASS BATT INSULATION
COLORS A-E: SEE GRAPHIC LEGENDCODE MIN R-VALUE: R:20 STD + R3.8 CIR-VALUE: R-20 STUD + R-8.8 CIUL DESIGN: U349FIRE RATING: 2 HOURS FROM EXTERIOR, 1 HOUR FROM INTERIORSTC RATING: 50 (EXTRAPOLATED)STC TEST: NGC 2015085HEIGHT: CONTINUOUS MIN.0' - 6"FOUNDATION
/10 A-509
LAYER TYPE X 5/8" ACOUSTIC GYPSUM WALL BD.
LAYER TYPE X 5/8" GYPSUM WALL BD.
LAYER TYPE X 5/8" ACOUSTIC GYPSUM WALL BD.
ELEVATOR EXTERIOR
5/8" FIRE-RATED PLYWOOD SHEATHING PER STRUCTURAL
VAPOR BARRIER
XE4 - EIFS FINISH: NO SHEAR @ ELEVATOR
2" EIFS SYSTEM2 LAYERS TYPE X 1" GYPSUM WALL BD. SHAFT LINER
FLOOR AND BASE FIN. AS SCHEDULE
AIR BARRIER
2" X 6" WOOD STUD, 16" O.C, FILLED WITH FIBERGLASS BATT INSULATION
COLORS A-E: SEE GRAPHIC LEGENDCODE MIN R-VALUE: R:20 STD + R3.8 CIR-VALUE: R-21.6 STUD + R-8.8 CIUL DESIGN: U349FIRE RATING: 2 HOURS FROM EXTERIOR, 1 HOUR FROM INTERIORSTC RATING: 50 (EXTRAPOLATED)STC TEST: NGC 2015085HEIGHT: CONTINUOUS MIN.0' - 6"FOUNDATION
/10 A-509
/3 A-509SIM
H CHANNEL, 24" O.C.
3/4" AIR SPACE
0' - 9 1/2"0' - 9 1/2"0' - 9 1/2"0' - 11"
INTERIOR EXTERIOR
XE5 - EIFS FINISH: STORAGE ROOM
2" EIFS SYSTEM
FLOOR AND BASE FIN. AS SCHEDULE
VAPOR BARRIER
NOMINAL 8" CMU WALL. PAINTED INTERIOR WALLS
COLORS A-E: SEE GRAPHIC LEGENDCODE MIN R-VALUE: LOW ENERGY BUILDING- NOT REQUIREDR-VALUE: R-15.5 CIUL DESIGN: U907FIRE RATING: 3 HOURSSTC RATING: 51STC TEST: HUD LISTINGHEIGHT: CONTINUOUS
FOUNDATION
/11 A-509
MIN.0' - 2"PAVEMENT
/3 A-509SIM
INTERIOREXTERIOR
XE6 - EIFS FINISH: TRASH ENCLOSURE
THINSET EIFS SYSTEM
VAPOR BARRIER
NOMINAL 8" CMU WALL. PAINTED INTERIOR WALLS
COLORS A-E: SEE GRAPHIC LEGENDCODE MIN R-VALUE: NOT REQUIREDR-VALUE: R-7.5 CIUL DESIGN: U907FIRE RATING: 3 HOURSSTC RATING: 45STC TEST: HUD LISTINGHEIGHT: CONTINUOUS
FOUNDATIONPAVEMENT
INTERIOREXTERIOR
XE7 - EIFS FINISH: TRASH ENCLOSURE
THINSET EIFS SYSTEM
VAPOR BARRIER
NOMINAL 4" CMU WALL. PAINTED INTERIOR WALLS
COLORS A-E: SEE GRAPHIC LEGENDCODE MIN R-VALUE: NOT REQUIREDR-VALUE: R-3.75 CIUL DESIGN: U907FIRE RATING: 3 HOURSSTC RATING: 40STC TEST: HUD LISTINGHEIGHT: CONTINUOUS
FOUNDATIONPAVEMENT
EXTERIOR EXTERIOR
5/8" EXTERIOR GWB (DENSGLAS OR SIMILAR)
VAPOR BARRIER
XE8 - EIFS FINISH: DOUBLE SIDED WING WALL
THINSET EIFS SYSTEM
5/8" EXTERIOR GWB (DENSGLAS OR SIMILAR)
AIR BARRIER
2" X 6" WOOD STUD, 16" O.C, FILLED WITH FIBERGLASS BATT INSULATION
COLORS A-E: SEE GRAPHIC LEGENDCODE MIN R-VALUE: NOT REQUIREDR-VALUE: NOT REQUIREDUL DESIGN: U349FIRE RATING: 2 HOURS FROM EXTERIOR, 1 HOUR FROM INTERIORSTC RATING: N/ASTC TEST: N/AHEIGHT: CONTINUOUS
FOUNDATION
VAPOR BARRIER
AIR BARRIER
ROOF
XE9 - EIFS FINISH: PARAPET
2" EIFS SYSTEM
5/8" EXTERIOR GWB (DENSGLAS OR SIMILAR)
2" X 6" WOOD STUD, 16" O.C, FILLED WITH FIBERGLASS BATT INSULATION
COLORS A-E: SEE GRAPHIC LEGENDCODE MIN R-VALUE: NOT REQUIREDR-VALUE: NOT REQUIREDUL DESIGN: U349FIRE RATING: 1 HOURSTC RATING: N/ASTC TEST: N/AHEIGHT: CONTINUOUS
EXTERIOR
5/8" EXTERIOR GWB (DENSGLAS OR SIMILAR)
VAPOR BARRIER
AIR BARRIER
VAPOR BARRIER
AIR BARRIER
TPO ROOFING
PARAPET CAP
THINSET EIFS SYSTEM
SIM
0' - 7 3/4"0' - 3 3/4"0' - 6 3/4"0' - 8 3/4"
XE-A / PT-A / PC-ABEIGE EIFS/MATCH SHERWIN-WILLIAMSPAINT / POWDER-COAT SW6154 NACRE (263-C2)
XE-B / PT-B / PC-BLIGHT BROWN EIFS / MATCH SHERWIN-WILLIAMSPAINT / POWDER-COAT SW7153 SANDERLING (248-C5)
GRAPHIC EXTERIOR MATERIAL LEGEND
XE-C / PT-C / PC-CMID BROWN EIFS /MATCH SHERWIN-WILLIAMSPAINT / POWDER-COAT SW7525 TREE BRANCH (288-C7)
XE-D / PT-D / PC-DRED BROWN EIFS / MATCH SHERWIN-WILLIAMSPAINT / POWDER-COAT SW6118 LEATHER BOUND (291-C7)
XE-E / PT-E / PC-EDARK BROWN EIFS / MATCH SHERWIN-WILLIAMSPAINT / POWDER-COAT SW7510 CHATEAU BROWN (242-C7)
XS-FMANUFACTURED STONE CULTURED STONE VENEER CLADDING COUNTRY LEDGESTONEASHFALL
XW-G / WD-1
WOOD-LOOK KNOTWOOD, 6" CLADDINGALUMINUM CLADDING WESTERN RED CEDAR
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216EXTERIOR WALL TYPES- EIFS
A-513
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
0'4" 8"1' 4"
SCALE: 1 1/2" = 1'-0"
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
Revision Schedule
Number Description Date
INTERIOREXTERIOR
5/8" EXTERIOR GWB (DENSGLAS OR SIMILAR)
VAPOR BARRIER
XS1 - STONE FINISH: NO SHEAR
LAYER TYPE X 5/8" GYPSUM WALL BD.
FLOOR AND BASE FIN. AS SCHEDULE
AIR BARRIER
2" X 6" WOOD STUD, 16" O.C, FILLED WITH FIBERGLASS BATT INSULATION
COLOR F: SEE GRAPHIC LEGENDCODE MIN R-VALUE: R:20 STD + R3.8 CIR-VALUE: R-20 STUD + R-5.6 CIUL DESIGN: U349FIRE RATING: 2 HOURS FROM EXTERIOR, 1 HOUR FROM INTERIORSTC RATING: 50 (EXTRAPOLATED)STC TEST: NGC 2015085HEIGHT: CONTINUOUS
FOUNDATIONPAVEMENT
INTERIOREXTERIOR
5/8" FIRE-RATED PLYWOOD SHEATHING PER STRUCTURAL EITHER SIDE
VAPOR BARRIER
LAYER TYPE X 5/8" ACOUSTIC GYPSUM WALL BD.
FLOOR AND BASE FIN. AS SCHEDULE
AIR BARRIER
2" X 6" WOOD STUD, 16" O.C, FILLED WITH FIBERGLASS BATT INSULATION
LAYER TYPE X 5/8" ACOUSTIC GYPSUM WALL BD.
EXTERIOREXTERIOR
1/2" CEMENT BOARD
VAPOR BARRIER
XE6 - STONE FINISH: DOUBLE-SIDED SOLID SURFACE
1/2" CEMENT BOARD
AIR BARRIER
2" X 4" WOOD STUD, 16" O.C
COLOR: SEE ENLARGED KITCHEN DRAWINGSCODE MIN R-VALUE: NOT REQUIREDR-VALUE: NOT REQUIREDUL DESIGN: U349FIRE RATING: 1 HOURSTC RATING: N/ASTC TEST: N/AHEIGHT: CONTINUOUS
FOUNDATION
VAPOR BARRIER
AIR BARRIER0' - 2"1" RIGID XPS INSULATION
FOUNDATION WEEP SCREED
XS2 - STONE FINISH: DOUBLE SHEAR
COLOR F: SEE GRAPHIC LEGENDCODE MIN R-VALUE: R:20 STD + R3.8 CIR-VALUE: R-20 STUD + R-5.8 CIUL DESIGN: U349FIRE RATING: 2 HOURS FROM EXTERIOR, 1 HOUR FROM INTERIORSTC RATING: 50 (EXTRAPOLATED)STC TEST: NGC 2015085HEIGHT: CONTINUOUS
+/- 0' - 10 1/2"
MANUFACTURED STONE VENEER OVER MORTAR SCRATCH AND SETTING BEDS
0' - 6 1/4"1" RIGID XPS INSULATION
FOUNDATION WEEP SCREED
FOUNDATION
+/- 0' - 10 1/2"
INTERIOR EXTERIOR
5/8" FIRE-RATED PLYWOOD SHEATHING PER STRUCTURAL WHERE REQUIRED
VAPOR BARRIER
LAYER TYPE X 5/8" ACOUSTIC GYPSUM WALL BD.
FLOOR AND BASE FIN. AS SCHEDULE
AIR BARRIER
2" X 8" STEEL MOMENT FRAME, 16" O.C, FILLED WITH FIBERGLASS BATT INSULATION
XS3 - STONE FINISH: NO SHEAR, POOL ROOM
COLOR F: SEE GRAPHIC LEGENDCODE MIN R-VALUE: R:20 STD + R3.8 CIR-VALUE: R-20 STUD + R-5.6 CIUL DESIGN: U349FIRE RATING: 2 HOURS FROM EXTERIOR, 1 HOUR FROM INTERIORSTC RATING: 53 (EXTRAPOLATED)STC TEST: NGC 2015085HEIGHT: CONTINUOUS MIN.0' - 6"1" RIGID XPS INSULATION
FOUNDATION WEEP SCREED
FOUNDATION
+/- 1' - 0 1/2"
EXTERIOR EXTERIOR
VAPOR BARRIER
2 LAYERS 5/8" EXTERIOR GWB (DENSGLAS OR SIMILAR)
FLOOR AND BASE FIN. AS SCHEDULE
AIR BARRIER
2" X 6" WOOD STUD, 16" O.C
XS4 - STONE FINISH: DOUBLE-SIDED WING
COLOR F: SEE GRAPHIC LEGENDCODE MIN R-VALUE: NOT REQUIREDR-VALUE: NOT REQUIREDUL DESIGN: U349FIRE RATING: 2 HOURS FROM EXTERIOR, 1 HOUR FROM INTERIORSTC RATING: N/ASTC TEST: N/AHEIGHT: CONTINUOUS
MANUFACTURED STONE VENEER
MIN.0' - 6"1" RIGID XPS INSULATION
FOUNDATION WEEP SCREED
FOUNDATION
5/8" EXTERIOR GWB (DENSGLAS OR SIMILAR)
+/- 0' - 11 1/4"
MANUFACTURED STONE VENEER OVER MORTAR SCRATCH AND SETTING BEDS
MANUFACTURED STONE VENEER OVER MORTAR SCRATCH AND SETTING BEDS
CABINET EXTERIOR
5/8" EXTERIOR GWB (DENSGLAS OR SIMILAR)
VAPOR BARRIER
XS5 - 2X4 STUD WALL @ OUTDOOR KITCHEN
5/8" EXTERIOR GWB (DENSGLAS OR SIMILAR)
AIR BARRIER
2" X 4" WOOD STUD, 16" O.C
COLOR F: SEE GRAPHIC LEGENDCODE MIN R-VALUE: NOT REQUIREDR-VALUE: NOT REQUIREDUL DESIGN: U349FIRE RATING: 1 HOURSTC RATING: N/ASTC TEST: N/AHEIGHT: -
FOUNDATION
MANUFACTURED STONE VENEER OVER MORTAR SCRATCH AND SETTING BEDS
3/4" SOLID SURFACE BACKSPLASH
EXTERIOREXTERIOR
5/8" EXTERIOR GWB (DENSGLAS OR SIMILAR)
VAPOR BARRIER
XE7 - STONE FINISH: STONE VENEER / SOLID SURFACE
1/2" CEMENT BOARD
AIR BARRIER
2" X 4" WOOD STUD, 16" O.C
COLOR F: SEE GRAPHIC LEGEND AND ENLARGED KITCHEN DRAWINGSCODE MIN R-VALUE: NOT REQUIREDR-VALUE: NOT REQUIREDUL DESIGN: U349FIRE RATING: 1 HOURSTC RATING: N/ASTC TEST: N/AHEIGHT: CONTINUOUS
FOUNDATION
VAPOR BARRIER
AIR BARRIER
3/4" SOLID SURFACE BACKSPLASH
MANUFACTURED STONE VENEER OVER MORTAR SCRATCH AND SETTING BEDS
ROOF
XE9 - STONE FINISH: PARAPET
5/8" EXTERIOR GWB (DENSGLAS OR SIMILAR)
2" X 6" WOOD STUD, 16" O.C
COLOR F: SEE GRAPHIC LEGENDCODE MIN R-VALUE: NOT REQUIREDR-VALUE: NOT REQUIREDUL DESIGN: U349FIRE RATING: 1 HOURSTC RATING: N/ASTC TEST: N/AHEIGHT: CONTINUOUS
EXTERIOR
5/8" EXTERIOR GWB (DENSGLAS OR SIMILAR)
VAPOR BARRIER
AIR BARRIERAIR BARRIER
TPO ROOFING
PARAPET CAP
0' - 7"
0' - 6"+/- 0' - 7 1/2"
INTERIOR
XE8 - STONE FINISH: SOFFIT
5/8" EXTERIOR GWB (DENSGLAS OR SIMILAR)
2" X 4" WOOD STUD, 16" O.C
COLORS A-E: SEE GRAPHIC LEGENDCODE MIN R-VALUE: NOT REQUIREDR-VALUE: NOT REQUIREDUL DESIGN: U349FIRE RATING: 1 HOURSTC RATING: N/ASTC TEST: N/AHEIGHT: CONTINUOUS
EXTERIOR
5/8" EXTERIOR GWB (DENSGLAS OR SIMILAR)
MANUFACTURED STONE VENEER OVER MORTAR SCRATCH AND SETTING BEDS
+/- 0' - 7"
MANUFACTURED STONE VENEER OVER MORTAR SCRATCH AND SETTING BEDS
XE-A / PT-A / PC-ABEIGE EIFS/MATCH SHERWIN-WILLIAMSPAINT / POWDER-COAT SW6154 NACRE (263-C2)
XE-B / PT-B / PC-BLIGHT BROWN EIFS / MATCH SHERWIN-WILLIAMSPAINT / POWDER-COAT SW7153 SANDERLING (248-C5)
GRAPHIC EXTERIOR MATERIAL LEGEND
XE-C / PT-C / PC-CMID BROWN EIFS /MATCH SHERWIN-WILLIAMSPAINT / POWDER-COAT SW7525 TREE BRANCH (288-C7)
XE-D / PT-D / PC-DRED BROWN EIFS / MATCH SHERWIN-WILLIAMSPAINT / POWDER-COAT SW6118 LEATHER BOUND (291-C7)
XE-E / PT-E / PC-EDARK BROWN EIFS / MATCH SHERWIN-WILLIAMSPAINT / POWDER-COAT SW7510 CHATEAU BROWN (242-C7)
XS-FMANUFACTURED STONE CULTURED STONE VENEER CLADDING COUNTRY LEDGESTONEASHFALL
XW-G / WD-1
WOOD-LOOK KNOTWOOD, 6" CLADDINGALUMINUM CLADDING WESTERN RED CEDAR
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216EXTERIOR WALL TYPES- STONE VENEER
A-514
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
0'4" 8"1' 4"
SCALE: 1 1/2" = 1'-0"
NOTE:SEE MANUFACTURER'S TECHNICAL SUBMITTAL PACKAGE FOR INSTALLATION DETAILS
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
Revision Schedule
Number Description Date
XE-A / PT-A / PC-ABEIGE EIFS/MATCH SHERWIN-WILLIAMSPAINT / POWDER-COAT SW6154 NACRE (263-C2)
XE-B / PT-B / PC-BLIGHT BROWN EIFS / MATCH SHERWIN-WILLIAMSPAINT / POWDER-COAT SW7153 SANDERLING (248-C5)
GRAPHIC EXTERIOR MATERIAL LEGEND
XE-C / PT-C / PC-CMID BROWN EIFS /MATCH SHERWIN-WILLIAMSPAINT / POWDER-COAT SW7525 TREE BRANCH (288-C7)
XE-D / PT-D / PC-DRED BROWN EIFS / MATCH SHERWIN-WILLIAMSPAINT / POWDER-COAT SW6118 LEATHER BOUND (291-C7)
XE-E / PT-E / PC-EDARK BROWN EIFS / MATCH SHERWIN-WILLIAMSPAINT / POWDER-COAT SW7510 CHATEAU BROWN (242-C7)
XS-FMANUFACTURED STONE CULTURED STONE VENEER CLADDING COUNTRY LEDGESTONEASHFALL
XW-G / WD-1
WOOD-LOOK KNOTWOOD, 6" CLADDINGALUMINUM CLADDING WESTERN RED CEDAR
INTERIOREXTERIOR
5/8" EXTERIOR GWB (DENSGLAS OR SIMILAR)
VAPOR BARRIER
XW1 - ALUMINUM SIDING: NO SHEAR
LAYER TYPE X 5/8" GYPSUM WALL BD.
FLOOR AND BASE FIN. AS SCHEDULE
AIR BARRIER
2" X 6" WOOD STUD, 16" O.C, FILLED WITH FIBERGLASS BATT INSULATION
COLOR G: SEE GRAPHIC LEGENDCODE MIN R-VALUE: R:20 STD + R3.8 CIR-VALUE: R-20 STUD + R-10.6 CIUL DESIGN: U349FIRE RATING: 2 HOURS FROM EXTERIOR, 1 HOUR FROM INTERIORSTC RATING: 50 (EXTRAPOLATED)STC TEST: NGC 2015085HEIGHT: CONTINUOUS
LAYER TYPE X 5/8" ACOUSTIC GYPSUM WALL BD.
XD3 - THERMAL SOFFIT, UNEXPOSED TO OUTSIDE
COLOR: INTERIOR FINISHES AS NOTEDCODE MIN R-VALUE: R:20 STD + R3.8 CIR-VALUE: R-20 STUD + R-5.3 CIUL DESIGN: U349FIRE RATING: 2 HOURS FROM EXTERIOR, 1 HOUR FROM INTERIORSTC RATING: 50 (EXTRAPOLATED)STC TEST: NGC 2015085HEIGHT: CONTINUOUS
2" RIGID XPS INSULATION
XD1 - COURTYARD CLOSET WALL
COLOR: INTERIOR FINISHES AS NOTEDCODE MIN R-VALUE: R:20 STD + R3.8 CIR-VALUE: R-20 STUD + R-5.3 CIUL DESIGN: U349FIRE RATING: 2 HOURS FROM EXTERIOR, 1 HOUR FROM INTERIORSTC RATING: 50 (EXTRAPOLATED)STC TEST: NGC 2015085HEIGHT: CONTINUOUS
6" WOOD-LOOK ALUMINUM CLADDING SLATS
XD4 - ELEVATOR SHAFT AT ROOF
COLOR: NO ADDITIONAL FINISHES NEEDEDCODE MIN R-VALUE: R:20 STD + R3.8 CIR-VALUE: R-20 STUD + R-5.3 CIUL DESIGN: U349FIRE RATING: 2 HOURS FROM EXTERIOR, 1 HOUR FROM INTERIORSTC RATING: 50 (EXTRAPOLATED)STC TEST: NGC 2015085HEIGHT: CONTINUOUS
ROOF
XWP - ALUMINUM SIDING: PARAPET
5/8" EXTERIOR GWB (DENSGLAS OR SIMILAR)
2" X 6" WOOD STUD, 16" O.C
COLOR G: SEE GRAPHIC LEGENDCODE MIN R-VALUE: R:20 STD + R3.8 CIR-VALUE: R-20 STUD + R-10.6 CIUL DESIGN: U349FIRE RATING: 2 HOURS FROM EXTERIOR, 1 HOUR FROM INTERIORSTC RATING: 50 (EXTRAPOLATED)STC TEST: NGC 2015085HEIGHT: CONTINUOUS
EXTERIOR
5/8" EXTERIOR GWB (DENSGLAS OR SIMILAR)
VAPOR BARRIER
AIR BARRIERAIR BARRIER
TPO ROOFING
PARAPET CAP
XD5 - VESTIBULE SOFFIT, UNEXPOSED TO OUTSIDE
COLOR: NO ADDITIONAL FINISHES NEEDEDUL DESIGN: U305FIRE RATING: N/ASTC RATING: N/ASTC TEST: N/AHEIGHT: TO CEILING
0' - 10"
2" RIGID XPS INSULATION
6" WOOD-LOOK ALUMINUM CLADDING SLATS
INTERIOR
XW2 - ALUMINUM SIDING: SOFFIT
5/8" EXTERIOR GWB (DENSGLAS OR SIMILAR)
2" X 4" WOOD STUD, 16" O.C
COLOR G: SEE GRAPHIC LEGENDCODE MIN R-VALUE: NOT REQUIREDR-VALUE: NOT REQUIREDUL DESIGN: U349FIRE RATING: 1 HOURSTC RATING: N/ASTC TEST: N/AHEIGHT: CONTINUOUS
EXTERIOR
5/8" EXTERIOR GWB (DENSGLAS OR SIMILAR)
6" WOOD-LOOK ALUMINUM CLADDING SLATS
0' - 5 1/4"0' - 9 1/4"
FOUNDATION
INTERIOR EXTERIOR
5/8" EXTERIOR GWB (DENSGLAS OR SIMILAR)
VAPOR BARRIER
LAYER TYPE X 5/8" GYPSUM WALL BD.
FLOOR AND BASE FIN. AS SCHEDULE
AIR BARRIER
2" X 6" WOOD STUD, 16" O.C, FILLED WITH FIBERGLASS BATT INSULATION
LAYER TYPE X 5/8" ACOUSTIC GYPSUM WALL BD.
1" RIGID XPS INSULATION
0' - 9"
BALCONY
2" X 4" WOOD STUD, 16" O.C
XD2 - BALCONY DEMISING WALL
1/2" FIBER CEMENT PANEL
COLOR: FINISHES AS NOTEDUL DESIGN: U305FIRE RATING: N/ASTC RATING: N/ASTC TEST: N/AHEIGHT: TO CEILING
BALCONY
ISOLATE WALL FROM BALCONY CEILING AND FLOOR
ISOLATE WALL FROM BALCONY CEILING AND FLOOR
BALCONY
INTERIOREXTERIOR
LAYER TYPE X 5/8" GYPSUM WALL BD.
VAPOR BARRIER
2 LAYERS TYPE X 5/8" GYPSUM WALL BD.
AIR BARRIER
2" X 6" WOOD STUD, 16" O.C, FILLED WITH FIBERGLASS BATT INSULATION1" RIGID XPS INSULATION
0' - 9"
ELEVATOREXTERIOR
5/8" EXTERIOR GWB (DENSGLAS OR SIMILAR)
VAPOR BARRIER
AIR BARRIER
1" RIGID XPS INSULATION
2 LAYERS TYPE X 1" GYPSUM WALL BD. SHAFT LINER
2" X 6" WOOD STUD, 16" O.C, FILLED WITH FIBERGLASS BATT INSULATION
H CHANNEL, 24" O.C.
3/4" AIR SPACE
1/4" COVER BOARD
TPO ROOFING
5/8" EXTERIOR GWB (DENSGLAS OR SIMILAR)
2" X 6" WOOD STUD, 16" O.C
VESTIBULEROOF
5/8" EXTERIOR GWB (DENSGLAS OR SIMILAR)
TPO ROOFING
VAPOR BARRIER
VAPOR BARRIER
AIR BARRIER
0' - 6 3/4"0' - 10"
XD6 - ELEVATOR PIT WALL
COLOR: NO ADDITIONAL FINISHES NEEDEDCODE MIN R-VALUE: R-10 CIR-VALUE: R-10.6 CIUL DESIGN: U349FIRE RATING: 3 HOURSSTC RATING: 57STC TEST: HUD LISTINGHEIGHT: SUB-GRADE
8" CAST-IN-PLACE CONCRETE WALL
VAPOR BARRIER
2" RIGID XPS INSULATION
ROOM
3-5/8" METAL STUD, 16" O.C
P9.1 METAL STUD, GWB SOFFIT
5/8" TYPE X GWB
P9.1- GWB ON METAL STUDUL DESIGN: N/AFIRE RATING: N/ASTC RATING: N/ASTC TEST: N/AHEIGHT: -0' - 4 1/4"CABINETRY
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216EXTERIOR WALL TYPES
A-515
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
0'4" 8"1' 4"
SCALE: 1 1/2" = 1'-0"
NOTE:SEE MANUFACTURER'S TECHNICAL SUBMITTAL PACKAGE FOR INSTALLATION DETAILS
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
Revision Schedule
Number Description Date
2" X 6" WOOD STUD, 16" O.C
P22X6 STUD, GENERAL PARTITION
5/8" TYPE X GWB
FLOOR AND BASE FIN. AS SCHEDULED
(P2.1) 5 1/2" BATT INSULATION
(P2.2) NO INSULATION
INTERIORINTERIOR
2" X 4" WOOD STUD, 16" O.C
P12X4 STUD, GENERAL PARTITION
5/8" TYPE X GWB
(P1.1) 3 1/2" BATT INSULATION
(P1.2) NO INSULATION
P1.1- INSULATEDUL DESIGN: U305FIRE RATING: N/ASTC RATING: 36STC TEST: NGC 2008029HEIGHT: TO CEILING
P1.2- UNINSULATEDUL DESIGN: U305FIRE RATING: N/ASTC RATING: 35STC TEST: NGC 2403HEIGHT: TO CEILING
INTERIORINTERIOR
P2.1- INSULATEDUL DESIGN: U305FIRE RATING: 1 HOURSTC RATING: 38STC TEST: NGC 2008032HEIGHT: TO DECK ABOVE
P2.2- UNINSULATEDUL DESIGN: U305FIRE RATING: 1 HOURSTC RATING: 35STC TEST: NGC 2403HEIGHT: TO DECK ABOVE
0' - 4 3/4"0' - 6 3/4"
2" X 6" WOOD STUD, 16" O.C
P22X6 STUD, GENERAL PARTITION
5/8" TYPE X GWB
INTERIORINTERIOR
P2.3- DOUBLE SHEARUL DESIGN: U305FIRE RATING: 1 HOURSTC RATING: 35STC TEST: NGC 2403HEIGHT: TO DECK ABOVE
1/2" OR 5/8" PLYWOOD SHEATHING, SEE STRUCTURAL
0' - 7 3/4" TO 0' - 8"
2" X 6" WOOD STUD, 16" O.C
P3 2X6 STUD, ACOUSTIC DEMISING
5/8" TYPE X ACOUSTIC GWB
NOISIER SIDE QUIETER SIDE
P3.3- DOUBLE SHEARUL DESIGN: U305FIRE RATING: 1 HOURSTC RATING: 57STC TEST: NGC 2010081HEIGHT: TO DECK ABOVE
1/2" OR 5/8" PLYWOOD SHEATHING, SEE STRUCTURAL
0' - 8 15/16" TO 0' - 9 3/16"
5/8" TYPE X GWB
FLOOR AND BASE FIN. AS SCHEDULEDFLOOR AND BASE FIN. AS SCHEDULED
SOUND ISOLATION CLIPS
2" X 6" WOOD STUD, 16" O.C
P3 2X6 STUD, ACOUSTIC DEMISING
5/8" TYPE X ACOUSTIC GWB
NON-SHEAR SIDE SHEAR SIDE
P3.2- SINGLE SHEARUL DESIGN: U305FIRE RATING: 1 HOURSTC RATING: 57STC TEST: NGC 2010081HEIGHT: TO DECK ABOVE
0' - 7 3/4" TO 0' - 7 7/8"
5/8" TYPE X GWB
RC-1 RESILIENT CHANNELS
5 1/2" BATT INSULATION
1/2" OR 5/8" PLYWOOD SHEATHING, SEE STRUCTURAL
5 1/2" BATT INSULATION
2" X 6" WOOD STUD, 16" O.C
P3 2X6 STUD, ACOUSTIC DEMISING
5/8" TYPE X ACOUSTIC GWB
P3.1- NON-SHEARUL DESIGN: U305FIRE RATING: 1 HOURSTC RATING: 57STC TEST: NGC 2010081HEIGHT: TO DECK ABOVE
0' - 7 1/4"
5/8" TYPE X GWB
RC-1 RESILIENT CHANNELS
(P3.1) 5 1/2" BATT INSULATION
NOISIER SIDE QUIETER SIDE
FLOOR AND BASE FIN. AS SCHEDULED FLOOR AND BASE FIN. AS SCHEDULEDFLOOR AND BASE FIN. AS SCHEDULED
2" X 6" WOOD STUD, 16" O.C
P42X6 STUD, 2 HR ACOUSTIC DEMISING
NON-SHEAR SIDESHEAR SIDE/STAIR
P4.2- SINGLE SHEARUL DESIGN: U301FIRE RATING: 2 HOURSSTC RATING: 61STC TEST: NGC 2011068HEIGHT: TO DECK ABOVE
0' - 9" TO 0' - 9 1/8"
RC-1 RESILIENT CHANNELS
1/2" OR 5/8" PLYWOOD SHEATHING, SEE STRUCTURAL
5 1/2" BATT INSULATION
2" X 6" WOOD STUD, 16" O.C
P42X6 STUD, 2 HR ACOUSTIC DEMISING
5/8" TYPE X ACOUSTIC GWB
P4.1- NON-SHEARUL DESIGN: U301FIRE RATING: 2 HOURSSTC RATING: 61STC TEST: NGC 2011068HEIGHT: TO DECK ABOVE
0' - 8 3/8"
2 LAYERS 5/8" TYPE X GWB
RC-1 RESILIENT CHANNELS
5 1/2" BATT INSULATION
NOISIER SIDE/STAIRQUIETER SIDE
FLOOR AND BASE FIN. AS SCHEDULEDFLOOR AND BASE FIN. AS SCHEDULED
1/2" TYPE X GWB
5/8" TYPE X ACOUSTIC GWB
5/8" TYPE X GWB
2 LAYERS 5/8" TYPE X GWB2" X 6" WOOD STUD, 16" O.C.
P42X6 STUD, 2 HR ACOUSTIC DEMISING
5/8" TYPE X ACOUSTIC GWB
PUBLIC SIDESTAIR
P4.3- DOUBLE SHEAR
UL DESIGN: U301FIRE RATING: 2 HOURSSTC RATING: 48 (EXTRAPOLATED)STC TEST: NGC 2009010 (EXTRAPOLATED)HEIGHT: TO DECK ABOVE
1/2" OR 5/8" PLYWOOD SHEATHING, SEE STRUCTURAL
0' - 9" TO 0' - 9 1/4"
5/8" TYPE X GWB
FLOOR AND BASE FIN. AS SCHEDULED
5/8" TYPE X GWB
5/8" TYPE X ACOUSTIC GWB
5 1/2" BATT INSULATION
P3.4- UNINSULATEDUL DESIGN: U305FIRE RATING: 1 HOURSTC RATING: N/ASTC TEST: N/AHEIGHT: TO DECK ABOVE
(P3.4) NO INSULATION
P52X6 STUD, ELEVATOR SHAFT
P5.1- NO SHEARUL DESIGN: U349FIRE RATING: 2 HOURSSTC RATING: 58STC TEST: NGC 2011069HEIGHT: TO DECK ABOVE
P5 2X6 STUD, ELEVATOR SHAFT
P5.2- SINGLE SHEAR
UL DESIGN: U349FIRE RATING: 2 HOURSSTC RATING: 58STC TEST: NGC 2011069HEIGHT: TO DECK ABOVE
2" X 6" WOOD STUD, 16" O.C.5/8" TYPE X GWB
5 1/2" BATT INSULATION
PUBLIC/BOH
FLOOR AND BASE FIN. AS SCHEDULED
1" TYPE X GWB SHAFT LINER
ELEVATOR
0' - 9"
H CHANNEL, 24" O.C.
3/4" AIR SPACE
2" X 6" WOOD STUD, 16" O.C.
1/2" OR 5/8" PLYWOOD SHEATHING, SEE STRUCTURAL
5 1/2" BATT INSULATION
PUBLIC/BOH
FLOOR AND BASE FIN. AS SCHEDULED
1" TYPE X GWB SHAFT LINER
ELEVATOR
0' - 9 3/8" TO 0' - 9 1/2"
H CHANNEL, 24" O.C.
3/4" AIR SPACE
5/8" TYPE X GWB
P5 2X6 STUD, SHAFT TO SHAFT
P5.3- NO SHEAR, SHAFT-TO-SHAFT
UL DESIGN: U305FIRE RATING: 2 HOURSSTC RATING: 35STC TEST: NGC 2403HEIGHT: TO DECK ABOVE
2" X 6" WOOD STUD, 16" O.C.
LINEN CHUTE
1" TYPE X GWB SHAFT LINER
ELEVATOR
H CHANNEL, 24" O.C.
3/4" AIR SPACE
1" TYPE X GWB SHAFT LINER
0' - 9 1/4"
INTERMEDIATE FLOOR INTERMEDIATE FLOOR
••
SPECIALTY GYPSUM BOARD NOTESUSE MOISTURE RESISTANT GWB IN RESTROOMS, POOL ROOM, LAUNDRY ROOMS, MEP ROOMS, FOOD PREP SPACES AND SPACES WITH KITCHENS WHERE ACOUSTIC OR HIGH IMPACT GWB IS NOT SPECIFIED.USE HIGH-IMPACT GWB IN BOH LAUNDRY AND LINEN ROOMSPARTITION LEGEND
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216PARTITION TYPES
A-516
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
0'4" 8"1' 4"
SCALE: 1 1/2" = 1'-0"
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
Revision Schedule
Number Description Date
2" X 4" WOOD STUD, 16" O.C
5/8" MOISTURE RESISTANT TYPE X GYPSUM WALL BD.
FLOOR AND BASE FIN. AS SCHEDULE
3 1/2" BATT INSULATION
PLUMBING SPACE / GAP
••
SPECIALTY GYPSUM BOARD NOTESUSE MOISTURE RESISTANT GWB IN RESTROOMS, POOL ROOM, LAUNDRY ROOMS, MEP ROOMS, FOOD PREP SPACES AND SPACES WITH KITCHENS WHERE ACOUSTIC OR HIGH IMPACT GWB IS NOT SPECIFIED.USE HIGH-IMPACT GWB IN BOH LAUNDRY AND LINEN ROOMS
2" X 6" WOOD STUD, 16" O.C.
P52X6 STUD, GUESTROOM WALL
SHAFT
SHAFT
P5.6- GUESTROOM WALL WITH ADDITIONAL LINER LAYERUL DESIGN: U305 + 1" SHAFT LINERFIRE RATING: 2 HOURSSTC RATING: 57STC TEST: NGC 2010081HEIGHT: TO DECK ABOVE
1" TYPE X GWB SHAFT LINER
IN BATHROOM SHAFT. IF SHAFT ON BOTH SIDES, ADD LINER ONLY ON ONE SIDE.
FLOOR AND BASE FIN. AS SCHEDULED
INTERIOR INTERIOR
2" X 4" WOOD STUD, 16" O.C
P62X4 STUD, 2 HR GENERAL PARTITION
2 LAYERS 5/8" TYPE X GWB EACH SIDE
P6- UNINSULATEDUL DESIGN: U301FIRE RATING: 2 HOURSSTC RATING: 40STC TEST: NGC 2363HEIGHT: TO DECK ABOVE
0' - 6"
FLOOR AND BASE FIN. AS SCHEDULED
P52X6 STUD, SHAFT DEMISING
P5.4- NO SHEAR, SHAFT-TO-SHAFTUL DESIGN: U305FIRE RATING: 1 HOURSTC RATING: N/ASTC TEST: N/AHEIGHT: TO DECK ABOVE
2" X 6" WOOD STUD, 16" O.C.
ELEVATOR
1" TYPE X GWB SHAFT LINER
ELEVATOR
1" TYPE X GWB SHAFT LINER
0' - 7 1/2"
P52X6 STUD, PLUMBING SHAFT
P5.5- METAL STUD, NO SHUL DESIGN: U415-BFIRE RATING: 2 HOURSSTC RATING: N/ASTC TEST: N/AHEIGHT: TO DECK ABOVE
2" X 6" WOOD STUD, 16" O.C.
ROOM
1" TYPE X GWB SHAFT LINER
SHAFT
5/8" TYPE X GWB SHAFT LINER
0' - 4 3/4"
INTERMEDIATE FLOOR
GUEST ROOM ORSHAFT
VARIES
P3.1P3.2
P3.3
P7 (2) 2X4 STUD, PLUMBING WALL
P7- PLUMBING WALLUL DESIGN: U341FIRE RATING: 1 HOURSTC RATING: 54STC TEST: NGC 2198HEIGHT: TO DECK ABOVE
ROOM
2" X 4" WOOD STUD, 16" O.C
P8 2X4 STUD, FURRED OUT
5/8" TYPE X GWB
P8- UNINSULATED STUDUL DESIGN: N/AFIRE RATING: N/ASTC RATING: N/ASTC TEST: N/AHEIGHT: TO CEILING
FLOOR AND BASE FIN. AS SCHEDULED
ROOM
3-5/8" METAL STUD, 16" O.C
P9METAL STUD, GWB SOFFIT
5/8" TYPE X GWB
P9.1- GWB ON METAL STUDUL DESIGN: N/AFIRE RATING: N/ASTC RATING: N/ASTC TEST: N/AHEIGHT: TO CEILING
FLOOR AND BASE FIN. AS SCHEDULED
0' - 4 1/4"
1' - 0"0' - 4 1/4"
ROOM
3-5/8" METAL STUD, 16" O.C
P9METAL STUD, PLASTIC LAM. SOFFIT
5/8" TYPE X GWB
P9.2- PLASTIC LAMINATE PLANKS ON METAL STUDUL DESIGN: N/AFIRE RATING: N/ASTC RATING: N/ASTC TEST: N/AHEIGHT: TO CEILING
FLOOR AND BASE FIN. AS SCHEDULED
0' - 5 1/4"
8" WIDE LAMINATE PLANK ON Z-CLIPS
ROOF ACCESSSTAIR
2" X 4" WOOD STUD, 16" O.C
P102X4 STUD, ROOF ACCESS WALL
5/8" TYPE X GWB
3 1/2" BATT INSULATION
P10- UNINSULATED BETWEEN ACCESS AND STAIRUL DESIGN: U305FIRE RATING: N/ASTC RATING: 35STC TEST: NGC 2403HEIGHT: -
0' - 4 3/4"
5/8" PLYWOOD OR OSB
CT-#TILE FINISH - SHOWER WALL
COLOR - AS NOTEDSHOWER WALL TILE INSTALLATIONINSTALL BACKING FOR ALL FIXTURES,GRAB BARS, ETC PER LEGENDSHEIGHT: TO CEILING
OPPOSITE INTERIOR
STUD WALL
1/2" CEMENT BACKER BOARD
VAPOR RETARDER
LIQUID APPLIED WATERPROOFING MEMBRANE
TILE OR SHOWER SURROUND PANEL AS SCHEDULED OVER CEMENTITIOUS BOND COAT
PREMANUFACTURED SHOWER BASE
CT-#TILE FINISH - AT TILE FLOOR
COLOR - AS NOTEDWALL TILE INSTALLATIONUL DESIGN: N/AFIRE RATING: N/ASTC RATING: N/ASTC TEST: N/AHEIGHT: TO CEILING
OPPOSITE INTERIOR
STUD WALL
1/2" CEMENT BACKER BOARD
VAPOR RETARDER
LIQUID APPLIED WATERPROOFING MEMBRANE
TILE AS SCHEDULED OVER CEMENTITIOUS BOND COAT
PARTITION LEGEND AND WALL FINISH DETAILS
SS-#SOLID SURFACE BACKSPLASH
COLOR - AS NOTEDSOLID SURFACE BACKSPLASH INSTALLATIONUL DESIGN: N/AFIRE RATING: N/ASTC RATING: N/ASTC TEST: N/AHEIGHT: AS NOTED IN INTERIOR ELEVATIONS
OPPOSITE INTERIOR
STUD WALL
1/2" CEMENT BACKER BOARD
THINSET
SOLID SURFACE BACKSPLASH
SOLID SURFACE COUNTER OVER 3/4" PLYWOOD
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216PARTITION TYPES
A-517
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
0'4" 8"1' 4"
SCALE: 1 1/2" = 1'-0"
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
Revision Schedule
Number Description Date
SUSPENEDED GWB CEILINGSEE RCPS FOR GWB TYPE.
SEE FLOOR-CEILING ASSEMBLY TYPES AND STRUCTURAL DRAWINGS TO DETERMINE FLOOR ASSEMBLY
NOTE: ALL CONSTRUCTION IN CONCEALED SPACE TO BE NON-
COMBUSTIBLE
SUSPENEDED GWB CEILINGSEE RCPS FOR GWB TYPE.
SEE FLOOR-CEILING ASSEMBLY TYPES AND STRUCTURAL DRAWINGS TO DETERMINE FLOOR ASSEMBLY
SUSPENEDED ACOUSTIC CEILINGSEE RCPS AND SCHEDULE FOR ACT TYPE. SEE MANUFACTURER'S DETAILS FOR ASSEMBLY OF EACH TYPE OF SYSTEM.
SEE FLOOR-CEILING ASSEMBLY TYPES AND STRUCTURAL DRAWINGS TO DETERMINE FLOOR ASSEMBLY
NOTE: ALL CONSTRUCTION IN CONCEALED SPACE TO BE NON-
COMBUSTIBLE
CL-A2X2 SUSPENDED ACOUSTIC CEILING
LOCATION: THROUGHOUT BUILDING AS NOTED
CL-A WHITE, FINE TEXTURE, CONCEALED SUSPENSION SYSTEM
CL-A1 GREY, FINE TEXTURE, CONCEALED SUSPENSION SYSTEM
CL-A2 WHITE, WASHABLE, CLEAN ROOM SUSPENSION SYSTEM
CL-BSUSPENDED GYPSUM BOARD CEILING (1 HOUR)
LOCATION: THROUGHOUT BUILDING AS NOTED
CL-B SUSPENDED SYSTEM, 1 LAYER TYPE X GWB, PT-01 FINISH
CL-B2 SUSPENDED SYSTEM, 1 LAYER MOISTURE-RESISTANT GWB, PT-01 FINISH
CL-B DIRECT-ATTACHED GYPSUM BOARD CEILING (1 HOUR)
LOCATION: BACK-OF-HOUSE SPACES AS NOTED
CL-B1 DIRECT-ATTACHED, 1 LAYER TYPE X GWB, PT-01 FINISH
CL-B3 DIRECT-ATTACHED, 1 LAYER MOISTURE-RESISTANT GWB, PT-01 FINISH
CEILING TYPES
SUSPENEDED GWB CEILINGSEE RCPS FOR GWB TYPE.
SEE FLOOR-CEILING ASSEMBLY TYPES AND STRUCTURAL DRAWINGS TO DETERMINE FLOOR ASSEMBLY
NOTE: ALL CONSTRUCTION IN
CONCEALED SPACE TO BE NON-
COMBUSTIBLE
SUSPENEDED GWB CEILINGSEE RCPS FOR GWB TYPE.
SEE FLOOR-CEILING ASSEMBLY TYPES AND STRUCTURAL DRAWINGS TO DETERMINE FLOOR ASSEMBLY
CL-DSUSPENDED FIBER CEMENT EXTERIOR SOFFIT
LOCATION: EXTERIOR UNDER CANOPIES, BALCONIES, AT ENTRY
CL-D SUSPENDED SYSTEM, 1 LAYER 1/2" FIBER CEMENT, PT-01FINISH
CL-D DIRECT-ATTACHED FIBER CEMENT EXTERIOR SOFFIT
LOCATION: BACK-OF-HOUSE SPACES AS NOTED
CL-B1 DIRECT-ATTACHED, 1 LAYER TYPE X GWB, PT-01 FINISH
CL-B3 DIRECT-ATTACHED, 1 LAYER MOISTURE-RESISTANT GWB, PT-01 FINISH
SUSPENEDED GWB CEILINGSEE RCPS FOR GWB TYPE.
SEE FLOOR-CEILING ASSEMBLY TYPES AND STRUCTURAL DRAWINGS TO DETERMINE FLOOR ASSEMBLY
NOTE: ALL CONSTRUCTION IN
CONCEALED SPACE TO BE NON-
COMBUSTIBLE
CL-CSUSPENDED GYPSUM BOARD CEILING (2 HOURS)
LOCATION: AT CEILINGS OF 2 HOUR RATED ROOMSUL DESIGN: L541FIRE RATING: 2 HOURSSTC/IIC RATINGS: SAME AS F1/F2 ASSEMBLIES
MIN. 2' - 0" BTW JOINTS
ADD SECOND LAYER OF 5/8" TYPE X GWB TO FLOOR-CEILING ASSEMBLY
CL-ESUSPENDED PLASTIC LAMINATE CEILING
LOCATION: AT LOBBY ENTRANCE
CL-E SUSPENDED SYSTEM, PLASTIC LAMINATE
SUSPENEDED PLASTIC LAMINATE CEILING. SEE RCPS FOR FINISH TYPE. SEE MANUFACTURER'S DETAILS FOR ASSEMBLY OF EACH TYPE OF SYSTEM.
SEE FLOOR-CEILING ASSEMBLY TYPES AND STRUCTURAL DRAWINGS TO DETERMINE FLOOR ASSEMBLY
NOTE: ALL CONSTRUCTION IN CONCEALED SPACE TO BE NON-COMBUSTIBLE
F111-7/8"X3/4" WEB JOIST BASE FLOOR-CEILING ASSEMBLY
••••
LOCATION: AT GUESTROOMSUL DESIGN: L570FIRE RATING: 1 HOURSTC RATING: 64IIC RATING: 54 (WITHOUT SUSPENDED CEILING)SOUND TEST: RAL-0T03NOTES:MINIMUM IIC BASED ON CERAMIC TILE FINISHMINIMUM STC BASED ON RESILIENT TILE FINISH DECREASED GWB BY 3/8" FROM TESTINCREASED GYP-CRETE BY 1/4" FROM TEST
F2.2 2"X8" JOIST FLOOR-CEILING ASSEMBLY
••
LOCATION: AT 3RD-5TH FLOOR CORRIDORSUL DESIGN: L516FIRE RATING: 1 HOURSTC RATING: 59IIC RATING: 62 (EXTRAPOLATED)SOUND TESTS: USG 74074 (STC)/USG 74075 (IIC)NOTES:DECREASED JOIST DEPTH BY 2" FROM TESTSINCREASED GYP-CRETE BY 1/2" FROM STC TEST
SEE STRUCT. FOR SPACING
MIN. 24" O.C.
SEE STRUT. FOR SPACING
MIN. 16" O.C.
F2.12"X8" JOIST WITH SOUND MAT FLOOR-CEILING ASSEMBLY
••
LOCATION: AT 2ND FLOOR CORRIDORUL DESIGN: L516FIRE RATING: 1 HOURSTC RATING: 59IIC RATING: 77SOUND TEST: RAL-IN04-005/TL04-032NOTES: DECREASED JOIST DEPTH BY 2" FROM TESTINCREASED GYP-CRETE BY 1/4" FROM TEST
SEE STRUT. FOR SPACING
MIN. 16" O.C.
FLOOR-CEILING ASSEMBLY TYPES
1 1/4" GYP-CRETE
1/4" ACOUSTIC UNDERLAYMENT
5/8" TYPE X GWB
RC-1 RESILIENT CHANNELS
PLYWOOD WEB JOIST, SEE STRUCT. FOR SIZE AND SPECS
3.5" FIBERGLASS BATT INSULATION ATTACHED TO BOTTOM OF PLYWOOD SUBFLOOR
3/4" T&G PLYWOOD SUBFLOOR
1 1/4" GYP-CRETE
5/8" TYPE X GWB
RC-1 RESILIENT CHANNELS
NOMINAL LUMBER JOIST, SEE STRUCT. TO VERIFY SIZE AND SPECS
3.5" FIBERGLASS BATT INSULATION ATTACHED TO BOTTOM OF PLYWOOD SUBFLOOR
3/4" T&G PLYWOOD SUBFLOOR
MAX. 18" CONCEALED SPACE0' - 11"1 1/4" GYP-CRETE
1/4" ACOUSTIC UNDERLAYMENT
5/8" TYPE X GWB
RC-1 RESILIENT CHANNELS
NOMINAL LUMBER JOIST, SEE STRUCT. TO VERIFY SIZE AND SPECS
3.5" FIBERGLASS BATT INSULATION ATTACHED TO BOTTOM OF PLYWOOD SUBFLOOR
3/4" T&G PLYWOOD SUBFLOOR
MAX. 18" CONCEALED SPACE0' - 11"MAX. 18" CONCEALED SPACE1' - 3 1/4"NOTE: WHEN ATTACHING GWB TO RC-1, DO NOT SHORT-CIRCUIT ACOUSTIC PATH BY SCREWING THROUGH RC-1 INTO WOOD JOIST
NOTE: WHEN ATTACHING GWB TO
RC-1, DO NOT SHORT-CIRCUIT
ACOUSTIC PATH BY SCREWING
THROUGH RC-1 INTO WOOD JOIST
NOTE: WHEN ATTACHING GWB TO
RC-1, DO NOT SHORT-CIRCUIT
ACOUSTIC PATH BY SCREWING
THROUGH RC-1 INTO WOOD JOIST
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216CEILING TYPES
A-518
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
0'4" 8"1' 4"
SCALE: 1 1/2" = 1'-0"
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
REVISION SCHEDULE
# DESCRIPTION DATE
2 ADDENDUM 2 6/21/2024
HANGER WIRES BY OTHERS
CONTROL JOINT
DRYWALL SUSPENSION MAIN TEE
DRYWALL SUSPENSION CROSS TEE
5/8" TYPE X GWB
APPLY AT JOINT, JOINT COMPOUND AND PAPER JOINT TAPE
UTAC UNOPPOSED TEE ATTACHMENT CLIPAT CONTROL JOINT, SECURE MAIN TEE TO CROSS TEE WITH UNOPPOSED TEE ATTACHMENT CLIP
HANGER WIRE BY OTHERS
CONTROL JOINT
APPLY AT JOINT, JOINT COMPOUND AND PAPER JOINT TAPE
DRYWALL SUSPENSION MAIN TEE
SUSPENSION CROSS TEE
5/8" TYPE X GWB
HANGER WIRE BY OTHERS
APPLY AT JOINT, JOINT COMPOUND AND PAPER JOINT TAPE
J-BEAD
APPLY ACOUSTICAL SEALANT AT PERIMETER JOINTS, TYPICAL.
DRYWALL SUSPENSION MAIN TEE
DRYWALL SUSPENSION CROSS TEE
SCREW GYPSUM BOARD INTO ANGLE MOLDING
5/8" TYPE X GWB
MOLDING ANGLE, SECURE TO WALL WITH APROPRIATE FASTENER, TYPICAL.
APPLY AT JOINT, JOINT COMPOUND AND PAPER JOINT TAPE
J-BEAD
APPLY ACOUSTICAL SEALANT AT PERIMETER JOINTS, TYPICAL.
MOLDING ANGLE, SECURE TO WALL WITH APROPRIATE FASTENER, TYPICAL.
DRYWALL SUSPENSION CROSS TEE
DRYWALL SUSPENSION MAIN TEE
HANGER WIRE BY OTHERS
SCREW GYPSUM BOARD TO ANGLE MOLDING
5/8" TYPE X GWB
APPLY AT JOINT, JOINT COMPOUND AND PAPER JOINT TAPE
DRYWALL SUSPENSION MAIN TEE
J-BEAD
APPLY ACOUSTICAL SEALANT AT PERIMETER JOINTS, TYPICAL.
0' - 0 3/8"
DRYWALL SUSPENSION CROSS TEE
5/8" TYPE X GWB
SCREW GYPSUM BOARD INTO ANGLE MOLDING
HANGER WIRE BY OTHERSMOLDING ANGLE, SECURE TO WALL WITH APROPRIATE FASTENER, TYPICAL.
MOLDING ANGLE, SECURE TO WALL WITH APROPRIATE FASTENER, TYPICAL.DRYWALL SUSPENSION CROSS TEE
DRYWALL SUSPENSION MAIN TEE
HANGER WIRE BY OTHERS
5/8" TYPE X GWBAPPLY AT JOINT, JOINT COMPOUND AND PAPER JOINT TAPE
J-BEAD
APPLY ACOUSTICAL SEALANT AT PERIMETER JOINTS, TYPICAL.
SCREW GYPSUM BOARD INTO ANGLE MOLDING
0' - 0 3/8"
HANGER WIRE BY OTHERS
APPLY AT JOINT, JOINT COMPOUND AND PAPER JOINT TAPE
DRYWALL SUSPENSION MAIN TEE
DRYWALL SUSPENSION CROSS TEE
5/8" TYPE X GWB
8" MAX.6" MAX.DRYWALL SUSPENSION CROSS TEE
J-BEAD
MITERED DRYWALL SUSPENSION MAIN TEE
CHANNEL MOLDING
CORNER BEAD
DRYWALL SUSPENSIONCROSS TEE
HANGER WIRE BY OTHERS
APPLY AT JOINT, JOINT COMPOUND AND PAPER JOINT TAPE
ANGLE MOLDING0' - 4"APPLY AT JOINT, JOINT COMPOUND AND PAPER JOINT TAPE
5/8" TYPE X GWB
5/8" TYPE X GWB
DRYWALL SUSPENSION CROSS TEE
APPLY AT JOINT, JOINT COMPOUND AND PAPER JOINT TAPE
TRANSITION CLIP OR METAL STUD
DRYWALL SUSPENSION MAIN TEE
ANGLE MOLDING
HANGER WIRE BY OTHERS
DRYWALL SUSPENSIONMAIN TEE
CORNER BEAD
NOTE: VERTICAL HEIGHTS OVER 6" REQUIRE DIAGONAL BRACINGJ-BEAD
CHANNEL MOLDING
5/8" TYPE X GWB
5/8" TYPE X GWB
APPLY AT JOINT, JOINT COMPOUND AND PAPER JOINT TAPE
APPLY AT JOINT, JOINT COMPOUND AND PAPER JOINT TAPE
ANGLE MOLDING
COMPASSO ELITE TRIM OR EQ. HEIGHT PER DRAWINGS
ATTACH BRACING TO TOP EDGE OF TRIM
BRACING, ATTACH EVERY 4'-0" FROM GRID BULB TO TOP OF TRIM. FASTEN WITH SELF-DRILLING SCREWS
FASTEN TO BULB OF GRID
DRYWALL SUSPENSION MAIN TEE
HANGER WIRE BY OTHERS
DRYWALL SUSPENSION CROSS TEE
FLOAT 2" - 6"
BEYOND GRID ATTACH FRAMING ANGLE AROUND ENTIRE PERIMETER 1/4" BACK FROM EDGE, SCREWS SPACED 16" O.C.
COMPASSO ELITE SPLICE CLIP OR EQ.
5/8" TYPE X GWB
HANGER WIRE BY OTHERS
APPLY AT JOINT, JOINT COMPOUND AND PAPER JOINT TAPE
DRYWALL SUSPENSION MAIN TEE
USG DRYWALL SUSPENSION CROSS TEE DGLW424
1/2" ALUMINUM REVEAL 5/8" TYPE X GWB
HANGER WIRES BY OTHERS
0' - 4"
DRYWALL SUSPENSION MAIN TEE
DRYWALL SUSPENSION CROSS TEE
APPLY AT JOINT, JOINT COMPOUND AND PAPER JOINT TAPE
PAPER FACED METAL "J" SHAPED TAPE-ON TRIM OR "L" SHAPED TAPE ON TRIM5/8" TYPE X GWB
M20 ANGLE MOLDING
UTAC UNOPPOSED TEE ATTACHMENT CLIP
HANGER WIRE BY OTHERS
DRYWALL SUSPENSION MAIN TEE
DRYWALL SUSPENSION CROSS TEE
5/8" TYPE X GWB
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216CEILING- SUSPENDEDGWB TYP. DETAILS
A-520
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
0'2" 4"8"
SCALE: 3" = 1'-0"
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
3" = 1'-0"1SUS. GWB CLNG.- CONTROL JOINT PARALLEL TO MAIN TEE
3" = 1'-0"2SUS. GWB CLNG.- CONTROL JOINT PERP. TO MAIN TEE
3" = 1'-0"6 SUS. GWB CLNG.- PANEL JOINT
3" = 1'-0"4SUS. GWB CLNG.- PERIMETER AT MAIN TEE
3" = 1'-0"5SUS. GWB CLNG.- PERIMETER AT CROSS TEE
3" = 1'-0"12 SUS. GWB CLNG.- PERIMETER TRIM AT MAIN TEE
3" = 1'-0"7SUS. GWB CLNG.- MAIN TEE AT PERIMETER WALL
3" = 1'-0"8SUS. GWB CLNG.- CROSS TEE AT PERIMETER WALL
3" = 1'-0"10SUS. GWB CLNG.- MAIN TEE AT PERIMETER WALL W/ RELEIF 3" = 1'-0"11SUS. GWB CLNG.- CROSS TEE AT PERIMETER WALL W/ RELEIF
3" = 1'-0"9 SUS. GWB CLNG.- TYPICAL REVEAL JOINT
3" = 1'-0"13SUS. GWB CLNG.- LOW PROFILE EDGE
3" = 1'-0"3 SUS. GWB CLNG.- TYPICAL SUSPENDED GWB DETAIL
REVISION SCHEDULE
# DESCRIPTION DATE
2 ADDENDUM 2 6/21/2024
HANGER WIRE BY OTHERS
HANGER WIRE BY OTHERS
APPLY AT JOINT, JOINT COMPOUND AND PAPER JOINT TAPE
ACOUSTIC TILE SYSTEM MAIN TEE
USG CPALAC1 COMPASSO ELITE CLIP OREQ.
COMPASSO ELITE TRANSITIONS DAS 4"TRIM OR EQ.
USG CPALAC1 COMPASSO ELITE CLIP OREQ.
DRYWALL SUSPENSION MAIN TEE
DRYWALL SUSPENSION CROSS TEE
ACOUSTICAL CEILING PANEL
5/8" TYPE X GWB
CHANNEL MOLDING
DRYWALL SUSPENSION CROSS TEE
HANGER WIRE BY OTHERS
APPLY AT JOINT, JOINT COMPOUND AND PAPER JOINT TAPE
DRYWALL SUSPENSION MAIN TEE
ACOUSTICAL SUSPENSION SYSTEM
CORNER BEAD
ACOUSTIC PANEL
J-BEAD
5/8" TYPE X GWB
ANGLE MOLDING
ANGLE MOLDING6" MAX.DRYWALL SUSPENSION MAIN TEE
APPLY AT JOINT, JOINT COMPOUND AND PAPER JOINT TAPE
DRYWALL SUSPENSION MAIN TEE, MITEREDOVERLAP & SCREW ATTACH. DO NOT CUTFACE OF TEE WHEN CREATING 90° BEND
ACOUSTIC TILE SYSTEM MAIN TEE
CORNER BEAD
ACOUSTICAL CEILING PANEL
J-BEAD
5/8" TYPE X GWB
ANGLE MOLDING
6" MAX.SHADOW MOLDING
CHANNEL MOLDING
DRYWALL SUSPENSION CROSS TEE
HANGER WIRE BY OTHERS
DRYWALL SUSPENSION MAIN TEE
HANGER WIRE BY OTHERS
DRYWALL SUSPENSION MAIN TEE
DRYWALL SUSPENSION CROSS TEE
INDEPENDENTLY HUNG SPRINKLER SWING-ARM ASSEMBLY (NOT SHOWN TO SCALE)
5/8" TYPE X GWB
APPLY AT JOINT, JOINT COMPOUND AND PAPER JOINT TAPE
DRYWALL SUSPENSION MAIN TEE, MITEREDOVERLAP & SCREW ATTACH. DO NOT CUTFACE OF TEE WHEN CREATING 90° BEND
ACOUSTIC TILE SYSTEM MAIN TEE
CORNER BEAD
ACOUSTICAL CEILING PANEL
J-BEAD
ANGLE MOLDING
ANGLE MOLDING6" MAX.5/8" TYPE X GWB
CHANNEL MOLDING
DRYWALL SUSPENSION CROSS TEE
HANGER WIRE BY OTHERS
DRYWALL SUSPENSION MAIN TEE
APPLY AT JOINT, JOINT COMPOUND AND PAPER JOINT TAPE
CORNER BEAD
5/8" TYPE X GWB
HANGER WIRE BY OTHERS
PER ARCHITECT
DRYWALL SUSPENSION MAIN TEE, MITEREDOVERLAP & SCREW ATTACH. DO NOT CUTFACE OF TEE WHEN CREATING 90° BEND
J-BEAD
CHANNEL MOLDING
PER ARCHITECTDRYWALL SUSPENSION CROSS TEE
5/8" TYPE X GWB
EDGE OF SOFFIT WITHOUT BACKLOAD
12" MAX. HANGAR WIRE TO
ANGLE MOLDING6" MAX.UTAC UNOPPOSED TEEATTACHMENT CLIP
DRYWALL SUSPENSIONCROSS TEE
DRYWALL SUSPENSION MAIN TEE
PER ARCHITECT
NOTE: LINEAR FIXTURE SHALL NOT EXCEED 3 LBS/FT [4.5 Kg/m]
DRYWALL SUSPENSIONCROSS TEE
DRYWALL SUSPENSION MAIN TEE
LINEAR LIGHT FIXTUREPER ARCHITECTEDGE OF SOFFIT WITH BACKLOAD
6" MAX. HANGAR WIRE TO6" MAX.UTAC UNOPPOSED TEEATTACHMENT CLIP
APPLY AT JOINT, JOINT COMPOUND AND PAPER JOINT TAPE
CORNER BEAD
5/8" TYPE X GWB
DRYWALL SUSPENSION MAIN TEE, MITEREDOVERLAP & SCREW ATTACH. DO NOT CUTFACE OF TEE WHEN CREATING 90° BEND
J-BEAD
CHANNEL MOLDING
DRYWALL SUSPENSION CROSS TEE
5/8" TYPE X GWB
ANGLE MOLDING
HANGER WIRE BY OTHERS
ACOUSTIC TILE SYSTEM MAIN TEE
HANGER WIRE BY OTHERS
5/8" TYPE X GWB
J-BEAD
DRYWALL SUSPENSION MAIN TEE, MITEREDOVERLAP & SCREW ATTACH. DO NOT CUTFACE OF TEE WHEN CREATING 90° BEND
CHANNEL MOLDING
DRYWALL SUSPENSIONTRANSITION CLIP
CORNER BEAD
ANGLE MOLDING
DRYWALL SUSPENSION CROSS TEE
12" MAX.
LINEAR LIGHT FIXTURE
BRACING, ANGLE MOLDING
4'-0" MAX.ANGLE MOLDING
ACOUSTICAL CEILING PANEL
APPLY AT JOINT, JOINT COMPOUND AND PAPER JOINT TAPE
5/8" TYPE X GWB
NOTE: LINEAR FIXTURE SHALL NOT EXCEED 3 LBS/FT [4.5 Kg/m]6" MAX.HANGER WIRE BY OTHERS
DRYWALL SUSPENSIONMAIN TEE
DRYWALL SUSPENSIONCROSS TEE
HINGE ASSEMBLY
ALUMINIUM FRAMED 23-5/8" X 23-5/8" ACCESS PANEL SYSTEM FOR 1/2" THICK DRYWALL PANELS - PROVIDED BY OTHERS. ATTACH FRAME TO BACKSIDE OF PANEL
APPLY JOINT FINISH COMPOUND AT ALL PANEL CUTS. FINISH PER INSTALLATION INSTRUCTIONS.
INSERT CUT OUT PERFORATED FIELD TO ARTICULATED ACCESS FRAME ASSEMBLY
LATCH / TOUCH LATCH ASSEMBLY NOTE: ORDER ACCESS PANEL FLANGE THICKNESS TO WORK WITH 5/8" [15.9] THICK DRYWALL.
5/8" TYPE X GWB
ATTACH STABILIZER BARS TO GRID. LOAD OF FIXTURE AND HOUSING TO BE SUPPORTED FROM STRUCTURE ABOVE, TYPICAL
TRIM RING RIM CLIPS, DO NOT OVER TIGHTEN
DRYWALL SUSPENSION CROSS TEE
HANGER WIRE BY OTHERS SUPPORT & BRACE LIGHT FIXTURE TO STRUCTURE ABOVE WITH ANGLES
DRYWALL SUSPENSION MAIN TEE
DRYWALL SUSPENSION CROSS TEE
5/8" TYPE X GWB
DRYWALL SUSPENSION MAIN TEE, MITEREDOVERLAP & SCREW ATTACH. DO NOT CUTFACE OF TEE WHEN CREATING 90° BEND
DRYWALL SUSPENSION CROSS TEE
DRYWALL SUSPENSION MAIN TEE
HANGER WIRE BY OTHERS
ANGLE MOLDING
TAPE AND FINISH CORNER AS REQUIRED
5/8" TYPE X GWB
3" = 1'-0"1SUS. GWB TO ACT CEILING - TRANSITION CLIP
3" = 1'-0"2SUS. GWB TO ACT CEILING - SHORT JOG WITH REVEAL
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216CEILING- SUSPENDEDGWB TYP. DETAILS
A-521
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
0'2" 4"8"
SCALE: 3" = 1'-0"
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
3" = 1'-0"3SUS. GWB TO ACT CEILING - FLUSH TRANSITION
3" = 1'-0"4SUS. GWB CLNG.- SPRINKLER HEAD
3" = 1'-0"5SUS. GWB TO ACT CEILING - SHORT JOG
3" = 1'-0"6SUS. GWB CLNG.- CANTILEVER W/O BACKLOAD HT. CHANGE
3" = 1'-0"7SUS. GWB CLNG.- CANTILEVER W/ BACKLOAD HT. CHANGE
3" = 1'-0"8 SUS. GWB TO ACT CEILING - LIGHT COVE AT TRANSITION
3" = 1'-0"9 SUS. GWB CLNG.- ACCESS PANEL DETAIL
3" = 1'-0"10 SUS. GWB CLNG.- LED DOWNLIGHT WITH IC HOUSING
3" = 1'-0"11SUS. GWB CLNG.- INSIDE CORNER
REVISION SCHEDULE
# DESCRIPTION DATE
2 ADDENDUM 2 6/21/2024
FFL
W-AW-BW-DW-EHEIGHTWIDTHHEAD HEIGHTW-F
WIDTH
HEAD HEIGHTHEAD HEIGHTHEIGHTWIDTH
HEIGHTHEAD HEIGHTWIDTH
HEIGHTWIDTH
HEAD HEIGHTHEIGHTSILLHEIGHTSILLHEIGHTSILLHEIGHTHEIGHTSILLHEIGHTSILLSOLID SURFACE SILL ONLY AT GUESTROOMW-CHEIGHTSILL HEIGHTHEAD HEIGHTWIDTH
EQEQ
W-GHEIGHTSILL HEIGHTHEAD HEIGHTWIDTH
EQ EQ
INTEGRAL LOUVER, INSTALL PER MANUFACTURER
SOLID SURFACE SILL ONLY AT GUESTROOMW-HHEIGHTSILL HEIGHTHEAD HEIGHTWIDTH
INTEGRAL LOUVER, INSTALL PER MANUFACTURER
SOLID SURFACE SILL ONLY AT GUESTROOMW-JHEIGHTSILL HEIGHTHEAD HEIGHTWIDTH
EQ EQ
SOLID SURFACE SILL ONLY AT GUESTROOMW-KHEIGHTSILL HEIGHTHEAD HEIGHTWIDTH
CW-A1CW-C
DT
DI
16' - 10"
DT
DI
DTDT
DIDI
4' - 3"4' - 2"4' - 2"4' - 3"7' - 1"4' - 1"D-121
DIDIDIDIDI
DTDTDTDT
4' - 0 3/4"3' - 11 3/4"4' - 0 3/4"
EQ. AEQ. AEQ. AEQ. BEQ. BEQ. BEQ. B
10' - 3 3/4"
EQ. A6' - 0"
12' - 1"
4' - 0 3/4"6' - 3"
DT
DI
10' - 3 3/4"
10' - 3 3/4"7' - 1"4' - 1"CW-A2CW-B
EQ. A6' - 0"
DI
DT11' - 2"11' - 2"CW-D8' - 6 3/4"2' - 7 1/4"EQ EQ
DT DT
DT DT11' - 2"WIDTH
CW-E6' - 1"1' - 11"DT
DI
8' - 0"7' - 8 1/2"
3' - 10 1/4"3' - 10 1/4"
DI
DT
CW-F
DI
DT
5' - 0"4' - 1 1/2"7' - 0 1/2"11' - 2"CW-G2' - 7 1/4"8' - 6 3/4"3' - 3 3/4"3' - 2 3/4" 3' - 3 3/4"
DT DT DT
DT DT DT11' - 2"9' - 10"
CW-H7' - 2"3' - 3"
3' - 0"
WIDTH
DT
7' - 0"7' - 1"HEIGHTWIDTH
3' - 3"
ST
ST
CW-K7' - 0"3' - 0"
12' - 1"
CW-M
D-122
DI DIDI
7' - 1"1' - 11"3' - 0 1/4"6' - 0 1/2"3' - 0 1/4"1' - 11"7' - 1"3' - 0 3/4"3' - 0" 3' - 1 1/2" 2' - 11 1/2"
CW-N
D-122A
DI DI DI
12' - 1 3/4"
CW-P 7' - 0"2' - 0"3' - 2"
DI
ST
5' - 5 1/2"
CW-J7' - 0"D-139A
3' - 0"
3' - 3"7' - 2"CW-L6' - 11 1/2"7' - 0 1/2"11' - 2"D-101DT
DI
5' - 1"
3' - 0"
3' - 3"
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216WINDOW TYPES ANDSCHEDULE
A-601
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
WINDOW SCHEDULE
MARKDESCRIPTIONOPERATION LOCATION
WINDOWFRAME GLAZING
FIRERATINGMAXU-FACTORPF NESW
MAXSHGCMINVLTACOUSTICQUANTITY COMMENTSWIDTH HEIGHT HEAD HT. SILL HT.
W-A STANDARD 8' WIDE PUBLIC WINDOWFIXED EXTERIOR 8' - 0" 5' - 2" 7' - 2" 2' - 0" ALUM/PC-04 DI NO 0.38 <0.2 W 0.38 0.6 -1
W-B STANDARD 5' WIDE PUBLIC WINDOWFIXED EXTERIOR 5' - 0" 5' - 2" 7' - 2" 2' - 0" ALUM/PC-04 DI NO 0.38 <0.2 S/W 0.38 0.6 -13
W-C STANDARD 4' WIDE PUBLIC WINDOWFIXED EXTERIOR 4' - 0" 5' - 2" 7' - 2" 2' - 0" ALUM/PC-04 DI NO 0.38 <0.2 N/E/S/W 0.38 0.6 -16
W-D 4' WIDE POOL WINDOWFIXED INTERIOR 4' - 0" 8' - 6" 9' - 6" 1' - 0" ALUM/PC-04 ST NO --- - 0.6 -1
W-E 3' WIDE POOL WINDOWFIXED INTERIOR 3' - 0" 8' - 6" 9' - 6" 1' - 0" ALUM/PC-04 ST NO --- - 0.6 -2
W-F KITCHEN HOOD DUCT LOUVERFIXED EXTERIOR
<varies><varies><varies> <varies> ALUM/PC-B LOUVER
NO --- - - -5
W-GSTANDARD 8' WIDE GUESTROOM WINDOW WITHINTEGRAL LOUVERSFIXED EXTERIOR 8' - 0" 5' - 2" 7' - 2" 2' - 0" ALUM/PC-04 DI
NO 0.38 <0.2 N/E/S/W 0.38 0.6 MIN. STC 35 ONSOUTH SIDE55
W-HSTANDARD 5' WIDE GUESTROOM WINDOW WITHINTEGRAL LOUVERSFIXED EXTERIOR 5' - 0" 5' - 2" 7' - 2" 2' - 0" ALUM/PC-04 DI
NO 0.38 <0.2 N/E/S/W 0.38 0.6 MIN. STC 35 ONSOUTH SIDE58
W-I KITCHEN HOOD DUCT LOUVERFIXED EXTERIOR 2' - 0" 2' - 0" 12' - 5 3/4"
10' - 53/4"ALUM/PC-B LOUVER
NO --- - - -1
W-K STANDARD 5' WIDE GUESTROOM WINDOWFIXED EXTERIOR 5' - 0" 5' - 2" 7' - 2" 2' - 0" ALUM/PC-04 DI
NO 0.38 VARIES N/E/S/W 0.38 0.6 MIN. STC 35 ONSOUTH SIDE35
W-L KITCHEN HOOD DUCT LOUVERFIXED EXTERIOR 0' - 10" 0' - 10"
10' - 101/2"10' - 01/2"ALUM/PC-C LOUVER
NO --- - - -2
CURTAIN WALL TYPES
FFL
WINDOW TYPES
1.
2.
3.
ALL WINDOW FRAMES AND STOREFRONTS TO BE POWDER-COATED ALUMINUM. VERIFY FINISH FOR POOL STOREFRONT WITH ARCHITECT. ALL FENESTRATION PRODUCTS SHALL BE LABELED WITH RATED U-FACTOR, SHGC, VT AND LEAKAGE RATING.FENESTRATION VALUES ARE NFRC PER MANUFACTURER.
WINDOW NOTES
FFL
CURTAIN WALL SCHEDULE
TYPELOCATIONINT/EXT
DIMENSIONS
FRAME GLAZING
FIRE
RATING
MAX. U
FACTORPF NESW
MAX.
SGHC
MIN
VLTMIN STC COMMENTSHEIGHT WIDTH
CW-A1 LOBBY NORTH WALLEXT. 11' - 2" 10' - 3 3/4" ALUM DT / DI NO0.38 >0.5 N 0.61 0.6 -
CW-A2 LOBBY NORTH WALLEXT. 11' - 2" 12' - 1" ALUM DT / DI NO0.38 >0.5 N 0.61 0.6 -
CW-B LOBBY NORTH WALLEXT. 11' - 2" 10' - 3 3/4" ALUM DT / DI NO0.38 >0.5 N 0.61 0.6 -
CW-C LOBBY NORTH WALLEXT. 11' - 2" 16' - 10" ALUM DT / DI NO0.38 >0.5 N 0.61 0.6 -
CW-D LOBBY SOUTH WALLEXT. 11' - 2" 8' - 7 1/2" ALUM DT NO0.38 <0.2 S 0.38 0.6 -
CW-D LOBBY SOUTH WALLEXT. 11' - 2" 8' - 7 1/2" ALUM DT NO0.38 >0.5 S 0.61 0.6 -
CW-D LOBBY SOUTH WALLEXT. 11' - 2" 9' - 3 1/2" ALUM DT NO0.38 >0.5 S 0.61 0.6 -
CW-E LOBBY VESTIBULE EAST EXT WALL EXT. 8' - 0" 8' - 1 1/4" ALUM DT / DI NO0.38 >0.5 E 0.61 0.6 -
CW-E LOBBY VESTIBULE WEST EXT WALL EXT. 8' - 0" 8' - 1 1/4" ALUM DT / DI NO0.38 >0.5 W 0.61 0.6 -
CW-F POOL EAST WALLEXT. 11' - 2" 5' - 0" ALUM DT / DI NO0.38 <0.2 E 0.38 0.6 - CORROSIVE ENVIRONMENT
CW-F POOL WEST WALLEXT. 11' - 2" 5' - 0" ALUM DT / DI NO0.38 <0.2 W 0.38 0.6 - CORROSIVE ENVIRONMENT
CW-G POOL NORTH WALLEXT. 11' - 2" 9' - 10" ALUM DT NO0.38 0.2-0.5 N 0.56 0.6 - CORROSIVE ENVIRONMENT
CW-H GUEST CORRIDOR TO VESTIBULEEXT. 7' - 2" 6' - 0 3/4" ALUM DT NO0.38 - - - 0.6 -
CW-H PUBLIC CORRIDOR TO VESTIBULEEXT. 7' - 2" 5' - 9 1/2" ALUM DT NO0.38 - - - 0.6 -
CW-H VESTIBULE WEST WALLEXT. 7' - 2" 5' - 9 1/2" ALUM DT NO0.38 >0.5 W 0.61 0.6 -
CW-J PUBLIC TO GUEST CORRIDORINT. 7' - 2" 5' - 9 1/2" ALUM ST NO- - - - 0.6 -
CW-K FITNESSINT. 10' - 0" 5' - 8 3/4" ALUM ST NO- - - - 0.6 -
CW-K LAUNDRY LOUNGEINT. 10' - 0" 5' - 1 1/4" ALUM ST NO- - - - 0.6 -
CW-K MEETING ROOM ENTRYINT. 11' - 0" 7' - 3 1/2" ALUM ST NO- - - - 0.6 MIN 35 ACOUSTIC SYSTEM
CW-L POOL EAST WALLEXT. 11' - 2" 5' - 1" ALUM DT / DI NO0.38 <0.2 E 0.38 0.6 - CORROSIVE ENVIRONMENT
CW-M LOBBY VESTIBULE EXT DOOREXT. 9' - 0" 12' - 1" ALUM DI NO0.38 >0.5 S 0.61 0.6 -
CW-N LOBBY VESTIBULE INT DOOREXT. 9' - 0" 12' - 8 1/2" ALUM DI NO0.38 - - - 0.6 -
CW-P LOBBY VESTIBULE EAST CLERESTORY EXT. 2' - 0"3' - 2" ALUM DI NO- - - - 0.6 -
CW-P LOBBY VESTIBULE WEST CLERESTORY EXT. 2' - 0"3' - 2" ALUM DI NO- - - - 0.6 -
0'2' 4'8'
SCALE: 1/4" = 1'-0"
GLAZING LEGEND
•••
•••
•
DT INSULATED DOUBLE PANE TEMPERED GLASS1/4" CLEAR TEMPERED GLASS1/2" AIRSPACE1/4" CLEAR TEMPERED, LOW "E" GLASS
DI INSULATED DOUBLE PANE GLASS
1/4" CLEAR GLASS1/2" AIRSPACE1/4" CLEAR LOW "E" GLASS
ST SINGLE PANE TEMPERED GLASS1/4" CLEAR TEMPERED GLASS
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
Revision Schedule
Number Description Date
D-A
WIDTH
HEIGHTD-B
WIDTH
HEIGHTD-C
WIDTH
HEIGHTD-DHEIGHTWIDTHHEIGHTWIDTH
D-EHEIGHTWIDTH
D-FD-GHEIGHTWIDTHHEIGHTWIDTH
EQEQ
D-HD-J7' - 0"VAR.3' - 0"
5' - 0"
D-K0' - 6"HEIGHT0' - 6"
WIDTH
7' - 0"6' - 0"
D-L
FFL
FFL
3' - 0"3' - 0"
#1: GUESTROOM ENTRY DOOR
3 EA. HINGES WITH HEAVY DUTY HINGE PIN STOP1 EA. ELECTRONIC LOCK SET (OWNER-SUPPLIED)1 EA. DOOR GUARD1 EA. TAMPER-PROOF 1-WAY VIEWER WITH SLIDING COVER1 EA. SMOKE SEAL DOOR GASKETING1 EA. STONE THRESHOLD1 EA. DOOR CLOSER WITH SPEED CONTROL1 EA. DOOR DROP
#2: GUESTROOM INTERIOR DOOR
3 EA. HINGES1 EA. PRIVACY SET1 EA. WALL STOP
#3: GUESTROOM CONNECTING DOOR
3 EA. HYDRAULIC AUTOMATIC HINGES WITH DOOR CLOSER, SPEED CONTROL & HOLD-OPEN FUNCTIONS1 EA. PASSAGE LATCHSET (LOW PROFILE, VERIFY THAT HANDLES WILL NOT CONFLICT WITHIN FRAME DEPTH) 1 EA. DEADBOLT1 EA. SMOKE SEAL DOOR GASKETING1 EA. DOOR DROP1 EA. DOOR GUARD1 EA. COMMUICATING DOOR THRESHOLD
#4: INTERIOR SLIDING ENTRY DOOR
1 EA. REMOTE ELECTRONIC LOCKSET INSIDE VESTIBULE (OWNER-SUPPLIED)1 EA. INTERCOM INSIDE VESTIBULEBALANCE OF HARDWARE BY DOOR SUPPLIER
#5: EXTERIOR STOREFRONT DOOR
1 EA. REMOTE ELECTRONIC LOCKSET (OWNER-SUPPLIED)BALANCE OF HARDWARE BY DOOR SUPPLIER
#6: LOCKSET, CLOSER, WALL STOP
3 EA. HINGES1 EA. ELECTRONIC LOCK SET (OWNER-SUPPLIED)1 EA. DOOR CLOSER1 EA. WALL STOP
#7: LOCKSET, DOOR STOP
3 EA. HINGES1 EA. ELECTRONIC LOCK SET (OWNER-SUPPLIED)1 EA. DOOR STOP AT WALL
#8: EMPLOYEE ROOM
3 EA. HINGES1 EA. KEY PAD1 EA. DOOR CLOSER1 EA. DOOR VIEWER1 EA. WALL STOP
#9: RESTROOM ENTRY DOORS
3 EA. HINGES1 EA. PUSH PLATES1 EA. DOOR CLOSER1 EA. WALL DOOR STOP
#10: PASSAGE, DOOR STOP
#11: UTILITY DOOR
#12: BOH LAUNDRY
3 EA. HINGES1 EA. KEYPAD1 EA. DOOR CLOSER WITH HOLD-OPEN2 EA. ARMOR PLATES1 EA. WALL STOP1 EA. PUSH/PULL PLATES
3 EA. HINGES1 EA. PASSAGE LATCH SET1 EA. DOOR STOP AT WALL
3 EA. HINGES1 EA. LOCK SET1 EA. DOOR CLOSER1 EA. THRESHOLD1 EA. DOOR SWEEP1 EA. WEATHERSTRIPPING1 EA. RAIN DRIP CAP
#13: UTILITY EXIT DOOR
3 EA. HINGES1 EA. PANIC HARDWARE EXIT DEVICE1 EA. DOOR CLOSER WITH HOLD-OPEN1 EA. THRESHOLD1 EA. DOOR SWEEP1 EA. WEATHERSTRIPPING1 EA. RAIN DRIP CAP1 EA. KICK PLATE
#14: INTERIOR STAIR
3 EA. HINGES1 EA. PANIC HARDWARE EXIT DEVICE1 EA. DOOR CLOSER1 EA. SMOKE SEAL DOOR GASKETING1 EA. WEATHERSTRIPPING1 EA. DOOR DROP1 EA. WALL STOP
#15: HOLD OPEN DOUBLE DOOR
6 EA. SWING CLR HINGES1 EA. LATCH SET2 EA. AUTO FLUSH TOP BOLT WITH FIRE PIN1 EA. MEETING STILE1 EA. COORDINATOR2 EA. DOOR CLOSER1 EA. SMOKE SEAL2 EA. MAGNETIC HOLD OPEN TIED TO FIRE ALARM
#16: NON-KEYED STOREFRONT DOOR
ALL HARDWARE BY DOOR SUPPLIER
#17: FOOD PREP DOOR
3 EA. HINGES1 EA. ELECTRONIC LOCK SET (OWNER-SUPPLIED)1 EA. DOOR CLOSER WITH HOLD-OPEN
#18: LINEN DISCHARGE DOOR
3 EA. HINGES1 EA. LATCH SET1 EA. DOOR CLOSER1 EA. SMOKE SEAL DOOR GASKETING1 EA. MAGNETIC HOLD OPEN TIED TO FIRE ALARM
#19: GUEST CORRIDOR HOLD-OPEN
6 EA. SWING CLR HINGES1 EA. ELECTRONIC LOCK SET (OWNER-SUPPLIED)1 EA. TAMPER-PROOF 1-WAY VIEWER WITH SLIDING COVER1 EA. FLUSH TOP BOLT AT INACTIVE PANEL2 EA. DOOR CLOSER WITH HOLD OPEN1 EA. WALL STOP
#21: SERVICE DOUBLE DOOR
6 EA. HINGES1 EA. ELECTRONIC LOCK SET (OWNER-SUPPLIED)1 EA. MEETING STILE2 EA. DOOR CLOSER WITH HOLD-OPEN
#20: BALCONY DOOR
3 EA. HINGES WITH HEAVY DUTY HINGE PIN STOP1 EA. NON-KEYED LOCKSET1 EA. WEATHERSTRIPPING1 EA. THRESHOLD1 EA. DOOR SWEEP1 EA. DOOR CLOSER
#22: EXTERIOR DOUBLE DOOR
6 EA. HINGES1 EA. REMOTE ELECTRONIC LOCK SET (OWNER-SUPPLIED)1 EA. MEETING STILE2 EA. DOOR CLOSER WITH HOLD-OPEN1 EA. THRESHOLD2 EA. DOOR SWEEP2 EA. WEATHERSTRIPPING2 EA. RAIN DRIP CAP2 EA. KICK PLATE
#23: EXTERIOR ENTRY DOOR
3 EA. HINGES1 EA. REMOTE ELECTRONIC LOCK SET (OWNER-SUPPLIED)1 EA. THRESHOLD1 EA. DOOR CLOSER1 EA. DOOR SWEEP1 EA. WEATHERSTRIPPING1 EA. RAIN DRIP CAP
#1A: ACCESSIBLE GUESTROOM ENTRY DOOR
#1: GUESTROOM ENTRY DOOR HARDWARE SET WITH2 EA. TAMPER-PROOF 1-WAY VIEWER WITH SLIDING COVER
#20A: PATIO DOOR
#20: BALCONY DOOR HARDWARE SET WITH1 EA. DEADBOLT
#7A: LOCKSET, DOOR STOP, ACOUSTIC
#7: LOCKSET, DOOR STOP WITH1 EA. SMOKE SEAL DOOR GASKETING1 EA. DOOR DROP 0' - 3"7
0
.
0
0
°3 SECONDSDOOR CLOSER
VIEWER - 2 REQUIRED AT ACCESSIBLE ROOMS - PROVIDE TAMPER PROOF 1-WAY VIEWER WITH SLIDING COVER
SOLID CORE WOOD DOOR
NOTES: VERIFY ALL DIMENSIONS WITH MANUFACTURER/ INDUSTRY STANDARDS/ APPLICABLE CODES.
ROOM SIGNAGE
DOOR GUARD
ELECTRONIC LOCKSET
TO TOP OF GUARD4'-0" (MAXIMUM)3' - 4"2 3/4" ACCESSIBLE ONLY3'-7"5'-0" TYPICAL℄℄
℄
℄
ACCESSIBLE DOORS: PROVIDE A SMOOTH SURFACE WITHIN 10" AFF VERTICALLY ON THE PUSH SIDE EXTENDING THE FULL WIDTH OF THE DOOR .
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216DOOR TYPES ANDSCHEDULE
A-602
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
FFL
DOOR SCHEDULE
MARK
ROOMINT. /EXT.
DOOR FRAME
HARDWARE FIRERATING MAX.U-FACTOR ADAREQ'D ACOUSTIC QUANTITY COMMENTSFrom To TYPE HEIGHT WIDTH THICKNESS HANDING MATERIAL FINISH GLAZING MATERIAL FINISH
D-001 001 EXT. D-E 7' - 0" 3' - 0" 0' - 1 3/4" LHR GALV. HM PC-B NO GALV. HM PC-B 23 NO 0.37 NO NO 1 KICKPLATE
D-001A 001 EXT.7' - 0" 6' - 0" 0' - 3" ROLL-UP INSULATED METAL PC-B NO GALV. HM PC-B 16 NO 0.37 NO NO 1
D-100 100A EXT. D-C 7' - 0" 3' - 0" 0' - 1 3/4" RHR ALUMINUM PC-04 FULL LITE, TI ALUMINUM PC-04 5 NO 0.38 YES NO 1
D-100A 100 100A EXT. D-C 7' - 0" 3' - 0" 0' - 1 3/4" LH ALUMINUM PC-04 FULL LITE, TI ALUMINUM PC-04 19 NO 0.38 YES NO 1
D-101 005 101 EXT. D-C 6' - 11 1/2" 3' - 0" 0' - 1 3/4" LHR ALUMINUM PC-04 FULL LITE, TI ALUMINUM PC-04 5 NO 0.38 YES NO 1 CORROSIVE ENVIRONMENT
D-101A 100 101 INT. D-C 7' - 0" 3' - 0" 0' - 1 3/4" RHR FRP PT-11 FULL LITE, SG FRP PT-11 6 NO -YES NO 1 CORROSIVE ENVIRONMENT
D-102 102 101 INT. D-G 7' - 0" 3' - 0" 0' - 1 3/4" RH FRP PT-11 NO FRP PT-11 2 NO -YES NO 1 CORROSIVE ENVIRONMENT, KICKPLATE
D-103 101 103 INT. D-G 7' - 0" 3' - 0" 0' - 1 3/4" RH FRP PT-11 NO FRP PT-11 7 NO -NO NO 1 CORROSIVE ENVIRONMENT, KICKPLATE
D-104 005 104 EXT. D-E 7' - 0" 4' - 6" 0' - 1 3/4" RHR GALV. HM PC-B NO GALV. HM PC-B 13 NO 0.37 NO NO 1
D-104A 104 100 INT. D-G 7' - 0" 3' - 0" 0' - 1 3/4" RHRA SCW PF-11 NO KD PF-11 6 NO -NO NO 1
D-105 100 105 INT. D-G 7' - 0" 3' - 6" 0' - 1 3/4" LH SCW PF-11 NO KD PF-11 12 NO -YES NO 1 KICKPLATE EXTENDING TO BOTTOM OF DOORHANDLE
D-105A 104 105A INT. D-G 7' - 0" 2' - 6" 0' - 1 3/4" LH HM PC-03 NO KD PF-03 10 1.5 HR -NO NO 1
D-106 100 106 INT. D-G 7' - 0" 3' - 0" 0' - 1 3/4" LH HM PC-11 NO KD PF-11 14 1.5 HR -YES NO 1 KICKPLATE
D-106A 106 EXT. D-E 7' - 0" 3' - 0" 0' - 1 3/4" LHR GALV. HM PC-B NO GALV. HM PC-B 13 1.5 HR 0.37 YES NO 1
D-107 105 107 INT. D-E 7' - 0" 3' - 6" 0' - 1 3/4" RHR HM PC-03 NO KD PF-03 18 1.5 HR -NO NO 1 KICKPLATE EXTENDING TO BOTTOM OF DOORHANDLE
D-108 100 108 INT. D-G 7' - 0" 3' - 0" 0' - 1 3/4" RH SCW PF-11 NO KD PF-11 6 NO -NO NO 1 KICKPLATE
D-108A 108 EXT. D-E 7' - 0" 4' - 6" 0' - 1 3/4" LHR GALV. HM PC-B NO GALV. HM PC-B 11 NO 0.37 NO NO 1
D-109 105 109A INT. D-G 7' - 0" 3' - 0" 0' - 1 3/4" LH SCW PF-03 NO KD PF-03 10 NO -YES NO 1 KICKPLATE EXTENDING TO BOTTOM OF DOORHANDLE
D-110 100 110 INT. D-G 7' - 0" 3' - 0" 0' - 1 3/4" LH SCW PF-11 NO KD PF-11 8 NO -YES NO 1
D-110A 110 110A INT. D-G 7' - 0" 3' - 0" 0' - 1 3/4" RH SCW PF-03 NO KD PF-03 2 NO -YES NO 1
D-110B 110 110B INT. D-G 7' - 0" 3' - 0" 0' - 1 3/4" LH SCW PF-03 NO KD PF-03 2 NO -NO NO 1
D-112 100 112 INT. D-C 7' - 0" 3' - 0" 0' - 1 3/4" LH ALUMINUM PC-11 FULL LITE, SG ALUMINUM PC-11 6 NO -YES NO 1
D-114 100 114 INT. D-C 7' - 0" 3' - 0" 0' - 1 3/4" RH ALUMINUM PC-11 FULL LITE, SG ALUMINUM PC-11 6 NO -YES NO 1
D-115 118 115 INT. D-G 7' - 0" 3' - 0" 0' - 1 3/4" LH SCW PF-11 NO KD PF-11 9 NO -YES NO 1
D-116 118 116 INT. D-G 7' - 0" 3' - 0" 0' - 1 3/4" RH SCW PF-11 NO KD PF-11 9 NO -YES NO 1
D-117 005 117 EXT. D-D 7' - 0" 3' - 0" 0' - 1 3/4" LHR GALV. HM PC-04 FULL DIVIDED LITE, TI GALV.HM PC-04 5 NO 0.38 YES NO 1
D-119 120 119 INT. D-H 7' - 0" 6' - 0" 0' - 1 3/4" RHRA SCW PF-11 NO KD PF-11 21 NO -NO NO 1
D-120 100 120 INT. D-C 7' - 0" 3' - 0" 0' - 1 3/4" LH ALUMINUM PC-04 FULL LITE, SG ALUMINUM PC-04 6 NO -YES YES 1
D-121 005 121 EXT. D-B 7' - 0" 6' - 0" 0' - 1 3/4" RHRA ALUMINUM PC-04 FULL LITE, TI ALUMINUM PC-04 5 NO 0.38 YES NO 1
D-122 006 122 EXT. D-A 7' - 0" 12' - 1" 0' - 1 3/4" OXXO ALUMINUM PC-04 FULL LITE, TI ALUMINUM PC-04 16 NO 0.38 YES NO 1
D-122A 122 121 EXT. D-A 7' - 0" 12' - 1 3/4" 0' - 1 3/4" OXXO ALUMINUM PC-04 FULL LITE, TI ALUMINUM PC-04 4 NO 0.38 YES NO 1
D-123 121A 123 INT. D-G 7' - 0" 3' - 6" 0' - 1 3/4" LH SCW PF-11 NO KD PF-11 17 NO -YES NO 1 KICKPLATE
D-124 121A 124 INT. D-G 7' - 0" 3' - 0" 0' - 1 3/4" RH SCW PF-11 NO KD PF-11 7 NO -YES NO 1
D-125 124 125 INT. D-K 7' - 0" 3' - 0" 0' - 1 3/4" LH SCW PF-03 VISION LITE, SG KD PF-03 7A NO -YES YES 1
D-126 124 126 INT. D-K 7' - 0" 3' - 0" 0' - 1 3/4" RH SCW PF-03 VISION LITE, SG KD PF-03 7A NO -YES YES 1
D-127 124 127 INT. D-K 7' - 0" 3' - 0" 0' - 1 3/4" RH SCW PF-03 VISION LITE, SG KD PF-03 7A NO -YES YES 1
D-128 121A 128 INT. D-G 7' - 0" 3' - 0" 0' - 1 3/4" LH SCW PF-11 NO KD PF-11 6 NO -NO NO 1
D-132 132 EXT. D-E 7' - 0" 3' - 0" 0' - 1 3/4" LHR GALV. HM PC-E NO GALV. HM PC-E 13 NO 0.37 YES NO 1
D-139 121A 139 INT. D-C 7' - 0" 3' - 0" 0' - 1 3/4" LH ALUMINUM PC-04 FULL LITE, SG ALUMINUM PC-04 19 20 MIN -YES NO 1
D-139A 139 139A INT. D-C 7' - 0" 3' - 0" 0' - 1 3/4" LH ALUMINUM PC-04 FULL LITE, SG ALUMINUM PC-04 16 20 MIN -YES NO 1
D-139B 139A EXT. D-D 7' - 0" 3' - 0" 0' - 1 3/4" RHR GALV. HM PC-04 FULL DIVIDED LITE, TI GALV. HM PC-04 23 NO 0.38 YES NO 1
D-141 141 EXT. D-L 7' - 0" 6' - 0" 0' - 1 3/4" RHRA GALV. HM PC-B NO GALV. HM PC-B 22 NO -YES NO 1
D-207 207 209 INT. D-H 7' - 0" 6' - 0" 0' - 1 3/4" RHRA SCW PF-03 NO KD PF-03 21 NO -YES NO 1 KICKPLATE
D-207A 207 207A INT. D-G 7' - 0" 3' - 0" 0' - 1 3/4" LH SCW PF-03 NO KD PF-03 7 NO -NO NO 1
D-207B 215 207 INT. D-G 7' - 0" 3' - 6" 0' - 1 3/4" LH SCW PF-11 NO KD PF-11 7 NO -YES NO 1 KICKPLATE
D-532 532 539 INT. D-G 7' - 0" 3' - 0" 0' - 1 3/4" LHR SCW PF-11 NO KD PF-11 7 NO -NO NO 1 KICKPLATE
GUEST ROOM DOOR SCHEDULE
MARKDESCRIPTION INT. /EXT.
DOOR FRAME
HARDWARE FIRERATING MAX. UFACTOR ADA REQ'D ACOUSTIC COMMENTSTYPE HEIGHT WIDTH THICKNESS HANDING MATERIAL FINISH GLAZING MATERIAL FINISH
D-G01 TYPICAL GUEST ROOM ENTRY DOOR INT. D-G 7' - 0" 3' - 0" 0' - 1 3/4" LH/RH SCW PL-01 NO KD PF-11 1 20 MIN -32" CLR YES
D-G01A TYPICAL ADA GUEST ROOM ENTRY DOOR INT. D-G 7' - 0" 3' - 0" 0' - 1 3/4" LH/RH SCW PL-01 NO KD PF-11 1A 20 MIN -YES YES
D-G02 TYPICAL GUEST ROOM CONNECTING DOOR INT. D-G 7' - 0" 3' - 0" 0' - 1 3/4" LHR/RHR SCW PF-03 NO KD PF-03 3 20 MIN -32" CLR YES 2 DOORS PER FRAME
D-G02A TYPICAL ADA GUEST ROOM CONNECTING DOOR INT. D-G 7' - 0" 3' - 0" 0' - 1 3/4" LHR/RHR SCW PF-03 NO KD PF-03 3 20 MIN - ON SIDE WITHADA ROOM YES 2 DOORS PER FRAME
D-G03 TYPICAL GUEST ROOM BATHROOM DOOR INT. D-G 7' - 0" 3' - 0" 0' - 1 3/4" LH/RH SCW PF-03 NO KD PF-03 2 NO -32" CLR -
D-G03A TYPICAL ADA GUEST ROOM BATHROOM DOOR INT. D-G 7' - 0" 3' - 0" 0' - 1 3/4" LH/RH SCW PF-03 NO KD PF-03 2 NO -YES -
D-G04 TYPICAL GUEST ROOM BALCONY DOOR EXT. D-F 7' - 0" 3' - 0" 0' - 1 3/4" LH/RH GALV. HM PC-04 YES- W/ INT. BLIND GALV. HM PC-04 20 NO 0.38 32" CLR YES 20A HARDWARE SET AT 1STFLOOR PATIO DOORS
D-G04A TYPICAL ADA GUEST ROOM BALCONY DOOR EXT. D-F 7' - 0" 3' - 0" 0' - 1 3/4" RH GALV. HM PC-04 YES- W/ INT. BLIND GALV. HM PC-04 20 NO 0.38 YES YES
D-G05 TYPICAL KING 1-BEDROOM INTERIOR DOOR INT. D-G 7' - 0" 3' - 0" 0' - 1 3/4" LH/RH SCW PF-03 NO KD PF-03 2 NO -32" CLR -
D-G05A TYPICAL ADA KING 1-BEDROOM INTERIOR DOOR INT. D-G 7' - 0" 3' - 0" 0' - 1 3/4" LH SCW PF-03 NO KD PF-03 2 NO -YES -
TYPICAL DOOR SCHEDULE
MarkDESCRIPTION
INT. /
EXT.
DOOR FRAME
HARDWARE
FIRE
RATING
MAX.
U-FACTOR
ADA
REQ'D ACOUSTIC COMMENTSTYPE HEIGHT WIDTH THICKNESS HANDING MATERIAL FINISH GLAZING MATERIAL FINISH
D-X06 STAIR DOOR FROM CORRIDOR INT. D-G 7' - 0" 3' - 0" 0' - 1 3/4" RH HM PC-11 NO KD PF-11 14 1.5 HR -YES NO KICKPLATE
D-X09 LINEN ROOM DOORINT. D-G 7' - 0" 4' - 0" 0' - 1 3/4" LH SCW PF-11 NO KD PF-11 8 NO -NO NO KICKPLATE EXTENDING TO BOTTOM OF DOOR HANDLE
D-X09B IDF CLOSET DOORINT. D-G 7' - 0" 2' - 4" 0' - 1 3/4" RHR SCW PF-03 NO KD PF-03 7 NO -NO NO
D-X09C DAC CLOSET DOORINT. D-G 7' - 0" 2' - 4" 0' - 1 3/4" RHR SCW PF-03 NO KD PF-03 7 NO -NO NO
D-X11 ELEVATOR DOORINT.7' - 0" 3' - 6"RH ELEV. SS SS NO SS CLEAR ELEV. 1.5 HR -YES NO
D-X11A ELEVATOR DOORINT.7' - 0" 3' - 6"RH ELEV. SS SS NO SS CLEAR ELEV. 1.5 HR -YES NO
D-X13 ELEVATOR DOORINT.7' - 0" 3' - 6"LH ELEV. SS SS NO SS CLEAR ELEV. 1.5 HR -YES NO
D-X15 ELECTRICAL CLOSET DOORINT. D-H 7' - 0" 5' - 0" 0' - 1 3/4" RHRA SCW PF-11 NO KD PF-11 21 NO -NO NO
D-X15B ROOM GROUP LOCK-OUT DOORS INT. D-J 7' - 0" 5' - 0" 0' - 1 3/4" RHR SCW PF-15 NO KD PF-15 19 NO -YES NO
D-X17 ELEVATOR LOBBY FIRE DOORS INT. D-H 7' - 0" 6' - 0" 0' - 1 3/4" RHRA SCW PF-15 NO KD PF-15 15 1.5 HR -YES NO
D-X32 STAIR DOOR FROM CORRIDOR INT. D-G 7' - 0" 3' - 0" 0' - 1 3/4" LH HM PC-11 NO KD PF-11 14 1.5 HR -YES NO KICKPLATE
1.2.3.4.5.6.7.8.9.10.11.12.13.
14.15.16.17.
18.
19.20.
REFER TO HOMEWOOD SUITES BY HILTON BRAND STANDARDS FOR ADDITIONAL TECHNICAL CRITERIA FOR DOORS, WINDOWS, FRAMES AND HARDWAREUSE KNOCK-DOWN DOOR FRAMES, TIMELY OR EQUIVALENT.PROVIDE 5 INCH STILES ON ALL DOORS AND/OR WINDOWS WHERE CARD READERS WILL BE MOUNTED.PROVIDE ACOUSTIC GASKETS AROUND ALL GUESTROOM DOORS.FOR DOORS IN POOL ROOM AND POOL SERVICE ROOMS: USE SEALANTS, MATERIALS AND FINISHES THAT ARE RATED FOR WET AND CORROSIVE ENVIRONMENTS.ALL DOOR AND FRAME FIRE RATINGS SHALL BE IN COMPLIANCE WITH LOCAL CODES AND JURISDICTIONSPROVIDE SMOKE SEALS/GASKETING WHERE REQUIREDPROVIDE WALL STOPS FOR ALL DOORS, UNLESS NOTED OTHERWISEPROVIDE WEATHERSTRIPPING AND THRESHOLD AT ALL EXTERIOR DOORS AS REQUIREDPROVIDE KICKPLATES WHERE REQUIREDDOOR SECURITY HARDWARE TO BE COORDINATE WITH SECURITY CONSULTANT; FINAL KEYING AND FUNCTION TO BE COORDINATED WITH OWNERPROVIDE SILENCERS ON ALL DOORS WITHOUT WEATHER STRIPPING OR SEALSACCESSIBLE DOORS: PROVIDE A SMOOTH SURFACE WITHIN 10" AFF VERTICALLY ON THE PUSH SIDE EXTENDING THE FULL WIDTH OF THE DOOR OR GATE - NOT REQUIRED FOR THE SLIDING DOORS. TEMPERED GLASS DOORS WITHOUT STILES AND HAVING A BOTTOM RAIL OR SHOE WITH THE TOP LEADING EDGE TAPERED AT 60 DEGREES MIN FROM THE HORIZONTAL ARE NOT REQUIRED TO MEET THE 10" BOTTOM SMOOTH SURFACE HEIGHT. ALL DOORS SHOULD HAVE A DOOR FORCE REQUIRED TO OPEN THE DOOR OF 5 LBS MAX. PROVIDE AN AUTOMATIC DOOR OPENER WITH STANDBY POWER TO OPERATE DOORS.FIRE RATED DOORS SHALL COMPLY WITH THE LOCAL FIRE AUTHORITY FOR FORCE REQUIRED TO OPEN THE DOOR IF NOT AT 5 LBS. PROVIDE ACCESIBLE REMOTE CARD READERS AT ALL EXTERIOR ENTRANCE DOORS, INCLUDING MAIN ENTRY, FITNESS CENTER, GUEST LAUNDRY AND INDOOR POOL. ALL DOOR FRAMES MUST HAVE A 32" MINIMUM CLEAR WIDTH OPENING WHEN DOOR IS FULLY OPEN. THRESHOLDS AT ACCESSIBLE DOORS TO MEET ALL APPROPRIATE ACCESSIBILITY REQUIREMENTS. ACCESSIBLE DOORS INCLUDE ALL PUBLIC ACCESS SPACES, ALL PUBLIC EXTERIOR DOORS, ALL EGRESS DOORS AND EMPLOYEE DOORS THAT ARE INDICATED WITH A CLEAR FLOOR AREA.EACH DOOR SUB-CONTRACTOR (ALUM. STOREFRONT/WOOD/HOLLOW METAL) SHALL BE RESPONSIBLE TO ADJUST ALL INTERIOR DOORS SO THAT THE DOORS REQUIRED OPENING FORCE IS 5 LBS OR LESS. ANY DOOR WITH A CLOSER SHALL BE ADJUSTED TO SLOW THE CLOSING TIME TO A MINIMUM OF 3 SECONDS, BUT NO MORE THAN 4 SECONDS FROM A STARTING POINT OF 70 DEGREES OPEN 3" FROM CLOSING. HARDWARE SHALL BE SELECTED TO ALLOW FOR CLOSING SPEED REQUIREMENTS FOR ACCESSIBLITY - REFER TO DIAGRAM. CHANGES IN LEVEL AT FLOOR TRANSITION PERMITTED TO BE 1/4" MAXIMUM OR 1/2" W/ 1:2 SLOPE (TYPICAL, ALL THRESHOLDS).ALL ELECTRONIC DOOR LOCKS TO BE OWNER-SUPPLIED.
DOOR NOTES
HARDWARE SCHEDULE
DOOR TYPES
1/2" = 1'-0"2 CLOSING DIAGRAM
GLAZING/FINISH LEGENDTI INSULATED DOUBLE PANE TEMPERED GLASSSG SINGLE PANE TEMPERED GLASSDG DOUBLE PANE TEMPERED GLASS
FRP FIBER REINFORCED POLYMERGALV HM GALVANIZED HOLLOW METALHM HOLLOW METAL
KD KNOCK-DOWN PREFINISH FRAMEPC POWDER-COATEDPF PRE-FINISHED
PL PLASTIC LAMINATEPT PAINTSCW SOLID CORE WOOD
3/8" = 1'-0"1ELEVATION AT GUEST ROOM ENTRY DOOR
0'1' 2'4'
SCALE: 1/2" = 1'-0"
0'1'-4" 2'-8"5''-4"
SCALE: 3/8" = 1'-0"
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
REVISION SCHEDULE
# DESCRIPTION DATE
2 ADDENDUM 2 6/21/2024
2
2
2
22
2
2
ACTACOUSTIC CEILING TILEASALUMINUM STOREFRONTCGCORNER GUARDCONC CONCRETE, UNFINISHEDCPCARPETCPTCARPET TILECSCONCRETE, FINISHEDGWBGYPSUM WALL BOARDFCFIBER CEMENTFRPFIBERGLASS-REINFORCEDPLASTICMR GWB MOISTURE-RESISTANT GWBPFPRE-FINISHED DOORPLPLASTIC LAMINATEPTPAINT/POWDER COATQTQUARRY TILERBRUBBER BASERESRESILIENT TILE FLOORSCSTAMPED CONCRETESFSPECIALTY FINISH (KNOCK DOWN)SSENGINEERED SOLID SURFACESTSTONESTLSTAINLESS STEELSTRUC STRUCTURE ABOVEVCTVINYL COMPOSITE TILEWCVINYL WALL COVERINGWDWOOD-LOOK ALUMINUM SLATS AND BATTENSWPSCREEN WALL
NOTE: REFER TO FF&E PACKAGE AND SPECIFICATION BOOK FOR FURNITURE AND FINISH SPECIFICATIONS
FINISH LEGEND
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216ROOM FINISHSCHEDULE
A-603
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
ROOM FINISH SCHEDULE
ROOM
FLOOR BASE
WALLCEILING
COMMENTSNO.NAMEMATERIAL FINISH MATERIAL FINISH HEIGHT
01. PUBLIC
100 PUBLIC CORRIDORCPTRB GWBPT GWBPT 10' - 0"
100A VESTIBULECT AS/RB AS/MR GWB AS / PT MR GWB PT 9' - 0"
101 POOL & SPLASH PAD CT/RES CT MR GWB PT MR GWB PT VARIES
102 POOL RESTROOMCTCT MR GWB CT MR GWB PT 9' - 0"
111 ELEV 1CTCT SHAFT STL GWBSTL 7' - 9"
112 LAUNDRY LOUNGECTCT MR GWB WC ACTACT 9' - 0"
113 ELEV 2CTCT SHAFT STL GWBSTL 7' - 9"
114 FITNESSRES RB GWB WC / PT ACT/GWB ACT/PT VARIES
115 WOMEN'S RESTROOMCTCT MR GWB WC / CT MR GWB PT 9' - 0"
116 MEN'S RESTROOMCTCT MR GWB WC / CT MR GWB PT 9' - 0"
118 GUEST STORAGECTRB GWBWC ACT/GWB ACT/PT VARIES
119 MEETING STORAGEVCTRB GWBPT GWB STRUC STRUC
120 MEETING ROOMCPTPT GWB WC / PT ACTACT 11' - 6"
121 LOBBYCT / CPT CT/RB GWB WC,SS,CT,PT ACT/GWB ACT/PT / PL VARIES
121A PUBLIC CORRIDORCTRB GWBPT GWBPT 10' - 0"
122 VESTIBULECTCT AS/MR GWB AS/PT MR GWB PT 9' - 0"
139 GUEST CORRIDORCPTRB GWBPTACTACT 8' - 6"
139A VESTIBULECT AS/CT AS/MR GWB AS / PT ACTACT 8' - 6"
X00 CONNECTING CORRIDOR CPTRB GWBPTACTACT 8' - 0"
X15 GUEST CORRIDORCPTRB GWBPTACTACT 8' - 0"
X17 ELEVATOR LOBBYCPTRB GWBPT GWBPT 8' - 6"
02. BOH
103 POOL MEPCONC RB MR GWB PT MR GWB PT 10' - 0"
104 ELECTRICALCONC RB MR GWB PT CONC STRUC STRUC
105 BOH LAUNDRYVCTRB MR GWB PTACTACT 10' - 0"
105A BOH DRYERSCONC RB MR GWB PT GWBPT 10' - 0"
107 LINEN DISCHARGE &SORTINGVCTRB GWBPT GWBPT 10' - 0"
108 WATER HEATER & FIRE CONC RB MR GWB PT STRUC PT STRUC
109 LINEN STORAGEVCTRB GWBPT GWBPT 10' - 0"
109A HOUSEKEEPING OFFICE VCTRB GWBPTACTACT 10' - 0"
110 EMPLOYEE ROOMVCTRB GWBWC ACTACT 9' - 0"
110A EMP RR ADACTCT MR GWB WC / CT MR GWB PT 9' - 0"
110B EMP RRCTCT MR GWB WC / CT MR GWB PT 9' - 0"
123 FOOD PREPQTQT MR GWB FRP ACTACT 11' - 0"
124 OPEN OFFICECPTRB GWBPTACTACT 9' - 0"
125 GM OFFICECPTRB GWBPTACTACT 9' - 0"
126 SALES OFFICECPTRB GWBPTACTACT 9' - 0"
127 OWNER'S OFFICECPTRB GWBPTACTACT 9' - 0"
128 ELECTRICALCONC RB GWBPT STRUC PT STRUC
139B ELECTRICALCPTRB GWBPT GWBPT 9' - 0"
140 LINEN CHUTECONC- SHAFT-GWB STRUC SHAFT
141 COURTYARD STORAGE CONC RB MR GWB PT STRUC PT STRUC
207 ENGINEERING OFFICE &STORAGEVCTRB GWBPT GWBPT 9' - 0"
207A PBX/MDFVCTRB GWBPT GWBPT 9' - 0"
X06 STAIR 1CPTRB GWBPT GWBSF STRUC
X09 LINENS & HOUSEKEEPING VCTRB GWBPT GWBPT 9' - 0"
X09A PANELSVCTRB GWBPT GWBPT 9' - 0"
X09B IDFVCTRB GWBPT GWBPT 9' - 0"
X09C DACVCTRB GWBPT GWBPT 9' - 0"
X15A ELECTRICALCPTRB GWBPT GWBPT 8' - 0"
X17 ELEVATOR LOBBYCPTRB MR GWB WC MR GWB PT 10' - 0"
X32 STAIR 2CPTRB GWBPT GWBSF STRUC
GUEST ROOM FINISH SCHEDULE
GR ROOM NAME
FLOOR BASE
WALLCEILING
COMMENTSROOMMATERIAL FINISH MATERIAL FINISH HEIGHT
ACCESSIBLE GUEST SUITE - KING 1-BEDROOM
LIVING AREARES / CPT RBGWB SF / WC GWB PT SMOOTH 8' - 0" NOTES, 1, 12
BEDROOMCPTRBGWB SF / WC GWB PT SMOOTH 8' - 0" NOTES, 1, 12
KITCHEN / DININGRESRB MR GWB WCGWB PT SMOOTH 8' - 0" NOTES, 1, 12
BATHROOMCTCT MR GWB WC MR GWB PT SMOOTH 7' - 6" NOTE 12
ACCESSIBLE GUEST SUITE - STUDIO/EFFICIENCY
LIVING AREA/SLEEPING AREARES / CPT RBGWB SF / WC GWB PT SMOOTH 8' - 0" NOTES, 1, 12
KITCHEN / DININGRESRB MR GWB WCGWB PT SMOOTH 8' - 0" NOTES, 1, 12
BATHROOMCTCT MR GWB WC MR GWB PT SMOOTH 7' - 6" NOTE 12
BALCONY/LANAI
BALCONY/LANAICONC- EXTERIOR -FCPT8' - 0"
TYPICAL/ENLARGED GUEST SUITE - KING 1-BEDROOM
LIVING AREARES / CPT RBGWB SF / WC GWB PT SMOOTH 8' - 0" NOTES, 1, 12
BEDROOMCPTRBGWB SF / WC GWB PT SMOOTH 8' - 0" NOTES, 1, 12
KITCHEN / DININGRESRB MR GWB WCGWB PT SMOOTH 8' - 0" NOTES, 1, 12
BATH/TOILETCTCT MR GWB WC MR GWB PT SMOOTH 7' - 6" NOTE 12
DRESSING AREA/LAVATORYCTCT MR GWB WC MR GWB PT SMOOTH 7' - 6" NOTE 12
TYPICAL/ENLARGED GUEST SUITE - STUDIO/EFFICIENCY
LIVING AREA/SLEEPING AREARES / CPT RBGWB SF / WC GWB PT SMOOTH 8' - 0" NOTES, 1, 12
KITCHEN / DININGRESRB MR GWB WCGWB PT SMOOTH 8' - 0" NOTES 1, 12
BATH/TOILETCTCT MR GWB WC MR GWB PT SMOOTH 7' - 6" NOTE 12
DRESSING AREA/LAVATORYCTCT MR GWB WC MR GWB PT SMOOTH 7' - 6" NOTE 12
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
REVISION SCHEDULE
# DESCRIPTION DATE
2 ADDENDUM 2 6/21/2024
2
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216FINISH SCHEDULE
A-604
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
REVISION SCHEDULE
# DESCRIPTION DATE
2 ADDENDUM 2 6/21/2024
XW-G ALUMINUM CLADDINGEXTERIOR ALUMINUM WOOD-LOOK CLADDINGKNOTWOOD6" CLADDING SYSTEMWESTERN RED CEDAR SPECIFICATION BOOK
XS-H RETAINING WALL BLOCKS SITE RETAINING WALLSVERTI-BLOCKCANYON LEGE TEXTURETAUPE (VERIFY WITH ARCHITECT)CONTRACTOR-SUPPLIED SPEC
XS-F STONE VENEEREXTERIOR STONE VENEERCULTURED STONECOUNTRY LEDGESTONEASHFALL 1.75" THICK NOMINAL SPECIFICATION BOOK
XE-E EIFSEXTERIOR EIFS FINISHPER CONTRACTORFINE-TEXTURED FINISHMATCH PT-E SPECIFICATION BOOK
XE-D EIFSEXTERIOR EIFS FINISHPER CONTRACTORFINE-TEXTURED FINISHMATCH PT-D SPECIFICATION BOOK
XE-C EIFSEXTERIOR EIFS FINISHPER CONTRACTORFINE-TEXTURED FINISHMATCH PT-C SPECIFICATION BOOK
XE-B EIFSEXTERIOR EIFS FINISHPER CONTRACTORFINE-TEXTURED FINISHMATCH PT-B SPECIFICATION BOOK
XE-A EIFSEXTERIOR EIFS FINISHPER CONTRACTORFINE-TEXTURED FINISHMATCH PT-A SPECIFICATION BOOK
WP-01 LOBBY SCREEN WALLLOBBY PARTITION SCREENSCORONA GROUPINTERSECTIONMATCH: FRAME: PC-04; SLATS: PL-01 45.75" X 8' OR 4' HIGH FINISH SPEC CHOICES
WD-10 ALUMINUM WOOD-LOOKOUTDOOR TRELLISES, RECEPTION CLOUD, COLUMN COVERSKNOTWOODSLATS, BEAMS, BATTENSWESTERN RED CEDAR MATCH FINISH FOR COLUMN COVERS DETAILS
WD-03 WOOD VENEERSTAIN GRADE WOOD VENEER - DARKSOLID WOODSTAIN GRADE WOOD VENEERRIFT SAWN WHITE OAK MATCH PL-04 SATIN TRANSPARENT STAIN SHEEN LEVEL OF 40 GU FINISH SPEC CHOICES
WD-02 WOOD VENEERSTAIN GRADE WOOD VENEER - CREAMSOLID WOODSTAIN GRADE WOOD VENEERRIFT SAWN WHITE OAK MATCH PL-03 SATIN TRANSPARENT STAIN SHEEN LEVEL OF 40 GU FINISH SPEC CHOICES
WD-01 WOOD VENEERSTAIN GRADE WOOD VENEER - LIGHTSOLID WOODSTAIN GRADE WOOD VENEERRIFT SAWN WHITE OAK MATCH PL-01 SATIN TRANSPARENT STAIN SHEEN LEVEL OF 40 GU FINISH SPEC CHOICES
WC-15 WALLCOVERINGPUBLIC RESTROOMMOMENTUM TEXTILE & WALLCOVERING DIVINEY47632DVZINC 52" OR 54" WIDE MILDEW RESISTANT ADHESIVE CG-15 FINISH SPEC CHOICES
WC-14 WALLCOVERINGGUEST LAUNDRYMOMENTUM TEXTILE & WALLCOVERING GRANARY SQUAREGOH 31981836TEAL 54" WIDE MILDEW RESISTANT ADHESIVE CG-14 FINISH SPEC CHOICES
WC-13 WALLCOVERINGFITNESSMOMENTUM TEXTILE & WALLCOVERING AVATARHLTN3104STORM FRONT 54" WIDE MILDEW RESISTANT ADHESIVE CG-13 FINISH SPEC CHOICES
WC-12 WALLCOVERINGCENTRAL HUBMOMENTUM TEXTILE & WALLCOVERING CONCOURSEGOH 31846883SAND 54" WIDE MILDEW RESISTANT ADHESIVE CG-12 FINISH SPEC CHOICES
WC-11 WALLCOVERINGGUEST CORRIDOR DOOR DROP, CENTRAL HUB ACCENT, MEETING ROOM ACCENT MOMENTUM TEXTILE & WALLCOVERING ANGLES MAXY47616AMDEEP SCARLET 52" WIDE MILDEW RESISTANT ADHESIVE CG-11 FINISH SPEC CHOICES
WC-10 WALLCOVERINGGUEST CORRIDOR AND MEETING ROOM MAINMOMENTUM TEXTILE & WALLCOVERING WATERCOLOR CANVASY47689WCSTONE 52" OR 54" WIDE MILDEW RESISTANT ADHESIVE CG-10 FINISH SPEC CHOICES
WC-02 WALLCOVERINGGUEST SUITE BATHROOM (TOILET AREA)MOMENTUM TEXTILE & WALLCOVERING REFLECTIONSHLTN3101RMORNING AIR 52" WIDE MILDEW RESISTANT ADHESIVE CG-02 FINISH SPEC CHOICES
WC-01 WALLCOVERINGGUEST SUITE, BATHROOM (DRESSING AREA)MOMENTUM TEXTILE & WALLCOVERING HOMEWOOD SUITES CUSTOMHMW-201CUSTOM 54" WIDE MILDEW RESISTANT ADHESIVE CG-01 FINISH SPEC CHOICES
VCT-01 VINYL COMPOSITION TILE EMPLOYEE ROOM???, BACK OF HOUSE ON FLOORS 2-5TARKETTTARKETT VCT II557- SHOOTING STAR 12"X12"FINISH SPEC CHOICES
TS-03 TRANSITION STRIPSTAIRSTARKETTJOHNSONITE STAIR NOSINGSLN-XX-A38- PEWTER 1/4" MATERIAL MATERIAL ON STEP AND RISER PT-14
TS-02 TRANSITION STRIPPUBLIC CARPETSPROLIFITECTRANSITIONSBRUSHED TITANIUM ALUMINUM FINISH SPEC CHOICES
TS-01 TRANSITION STRIPGUESTROOM CARPETSTARKETTSLIM LINE TRANSITIONSSLT-29-A29- MOON ROCK FINISH SPEC CHOICES
STL STAINLESS STEELCABINETS AND EQUIPMENT FF&E SPECS
ST-01 STONEGUEST SUITE ENTRY DOOR THRESHOLDDAL-TILEMARBLEM701- CARRARA WHITE 2"X36"X3/8"POLISHED DOUBLE BEVEL EDGE FINISH SPEC CHOICES
SS-10 SOLID SURFACECOUNTERTOP AT OUTDOOR KITCHENDAL-TILEQUARTZNQ52- GREY VELVET 2MM THICK POLISHED SQUARE EDGE FINISH SPEC CHOICES
SS-02 SOLID SURFACEGUEST SUITE WINDOWSILLDAL-TILEQUARTZNQ47- WHITE SAND 2MM THICK POLISHED SQUARE EDGE FINISH SPEC CHOICES
SS-01 SOLID SURFACEGUEST SUITE AND PUBLIC SPACE COUNTERTOPS AND ES LOW WALL TOPDAL-TILEQUARTZOQ48- INDEPENDENCE CALCUTTA 2MM THICK POLISHED SQUARE EDGE FINISH SPEC CHOICES
SF-01 KNOCK-DOWN FINISHGUEST SUITE EXTERIOR WALLSHERWIN-WILLIAMS100% ACRYLIC KNOCK-DOWN FINISH SW7042SHOJI WHITE EGGSHELL MIN 1 COAT PRIMER, 2 COATS PAINT FINISH SPEC CHOICES
SC-01 STAMPED CONCRETEEXTERIOR CONCRETE SURFACES AT PORTE COCHERE AND COURTYARDSCOFIELD/SIKASLATE/STONE TEXTUREOWNER TBD -
RES-13 RESILIENT FLOORINGSPLASH PAD (SPLASH PAD PERIMETER)LIFE FLOOR3/8" THICK TILE-GX.30 - FOGHORN 12"X24"X3/8"PATTERN - SLATE FINISH SPEC CHOICES
RES-12 RESILIENT FLOORINGSPLASH PAD (SPLASH PAD AREA)LIFE FLOOR3/8" THICK TILE-TX.30 - AQUA 12"X24"X3/8"PATTERN - RIPPLE FINISH SPEC CHOICES
RES-11 RESILIENT FLOORINGFINESS FLOOR (STRENGTH AND FUNCTIONAL)ECORE COMMERCIAL FLOORINGMOTIVATEES505CHARCOAL 48"X25LFX7.5MM DRY-LAY INSTALLATION FINISH SPEC CHOICES
RES-10 RESILIENT FLOORINGFITNESS FLOOR (CARDIO)ECORE COMMERCIAL FLOORINGSTRAIT RX6624SEA GRASS 72"X30LFX7MM DRY-LAY INSTALLATION FINISH SPEC CHOICES
RES-01 RESILIENT FLOORINGGUEST SUITE FLOORTARKETTHOMEWOOD SUITES CUSTOMX-6641 7"X48"CLICK-IN, ASHLAR FINISH SPEC CHOICES
RB-11 VINYL BASEFITNESS BASETARKETTMONUMENTMW-48-S448- GREY 4" HIGH 45 DEG MITER ON CORNERS FINISH SPEC CHOICES
RB-10 VINYL BASEGUEST CORRIDOR, MEETING ROOM, CENTRAL HUB BASETARKETTMONUMENTMW-24-S424- GREY HAZE 4" HIGH 45 DEG MITER ON CORNERS FINISH SPEC CHOICES
RB-01 VINYL BASEGUEST SUITE BASETARKETTMONUMENTMW-27-S427- MIST 4" HIGH 45 DEG MITER ON CORNERS FINISH SPEC CHOICES
QT-10.1 QUARRY TILE BASEFOOD PREP FLOORDAL-TILEQUARRY QUE-TREAD SERIESOQ94- BEIGE- PAVER 6"X6"X1/2"STACKED BOND VERIFY COLOR WITH ARCHITECT GROUT GR-07 FINISH SPEC CHOICES
QT-10 QUARRY TILEFOOD PREP FLOORDAL-TILEQUARRY QUE-TREAD SERIESOQ94- BEIGE- PAVER 6"X6"X1/2"STACKED BOND VERIFY COLOR WITH ARCHITECT GROUT GR-07 FINISH SPEC CHOICES
PT-E EXTERIOR PAINTFIBER CEMET SOFFITS, FASCIAS, EXTERIOR ELEMENTSSHERWIN-WILLIAMSTYPE TO MATCH SUBSTRATESW7510CHATEAU BROWN (242-C7)EGGSHELL MIN 1 COAT PRIMER, 2 COATS PAINT FINISH SPEC CHOICES
PT-D EXTERIOR PAINTFIBER CEMET SOFFITS, FASCIAS, EXTERIOR ELEMENTSSHERWIN-WILLIAMSTYPE TO MATCH SUBSTRATESW6118LEATHER BOUND (291-C7)EGGSHELL MIN 1 COAT PRIMER, 2 COATS PAINT FINISH SPEC CHOICES
PT-C EXTERIOR PAINTFIBER CEMET SOFFITS, FASCIAS, EXTERIOR ELEMENTSSHERWIN-WILLIAMSTYPE TO MATCH SUBSTRATESW7525TREE BRANCH (288-C7)EGGSHELL MIN 1 COAT PRIMER, 2 COATS PAINT FINISH SPEC CHOICES
PT-B EXTERIOR PAINTFIBER CEMET SOFFITS, FASCIAS, EXTERIOR ELEMENTSSHERWIN-WILLIAMSTYPE TO MATCH SUBSTRATESW7153SANDERLING (248-C5)EGGSHELL MIN 1 COAT PRIMER, 2 COATS PAINT FINISH SPEC CHOICES
PT-A EXTERIOR PAINTFIBER CEMET SOFFITS, FASCIAS, EXTERIOR ELEMENTSSHERWIN-WILLIAMSTYPE TO MATCH SUBSTRATESW6154NACRE (263-C2)EGGSHELL MIN 1 COAT PRIMER, 2 COATS PAINT FINISH SPEC CHOICES
PT-15 PAINTCENTRAL HUB BASE, HOLD OPEN DOORSSHERWIN-WILLIAMSPRO-MAR 200 ZERO VOC SEMI-GLOSS SW7029AGREEABLE GRAY SEMI-GLOSS MIN 1 COAT PRIMER, 2 COATS PAINT FINISH SPEC CHOICES
PT-14 PAINTFITNESS EXTERIOR WALLSHERWIN-WILLIAMSPRO-MAR 200 ZERO VOC LOW GLOSS SW7655STAMPED CONCRETE EGGSHELL MIN 1 COAT PRIMER, 2 COATS PAINT FINISH SPEC CHOICES
PT-13 PAINTGUEST LAUNDRY EXTERIOR WALLSHERWIN-WILLIAMSPRO-MAR 200 ZERO VOC LOW GLOSS SW9132ACACIA HAZE EGGSHELL MIN 1 COAT PRIMER, 2 COATS PAINT FINISH SPEC CHOICES
PT-12 PAINTCENTRAL HUB EXTERIOR WALLSHERWIN-WILLIAMSPRO-MAR 200 ZERO VOC LOW GLOSS SW7029AGREEABLE GRAY EGGSHELL MIN 1 COAT PRIMER, 2 COATS PAINT FINISH SPEC CHOICES
PT-11 PAINTGUEST CORRIDOR SERVICE DOORS, ACCESS PANELS, TRIMSHERWIN-WILLIAMSPRO-MAR 200 ZERO VOC SEMI-GLOSS SW7030ANEW GRAY SEMI-GLOSS MIN 1 COAT PRIMER, 2 COATS PAINT FINISH SPEC CHOICES
PT-10 PAINTGUEST CORRIDOR EXTERIOR WALLSHERWIN-WILLIAMSPRO-MAR 200 ZERO VOC LOW GLOSS SW7030ANEW GRAY EGGSHELL MIN 1 COAT PRIMER, 2 COATS PAINT FINISH SPEC CHOICES
PT-05 PAINTPOWDER COAT FINISHSHERWIN-WILLIAMSPRO-MAR 200 ZERO VOCMATCH PC-05 VERIFY WITH ARCHITECT MIN 1 COAT PRIMER, 2 COATS PAINT FINISH SPEC CHOICES
PT-04 PAINTDOORS, WINDOWS, STOREFRONT, METALWORKSHERWIN-WILLIAMSPRO-MAR 200 ZERO VOCMATCH PC-04 VERIFY WITH ARCHITECT MIN 1 COAT PRIMER, 2 COATS PAINT FINISH SPEC CHOICES
PT-03 PAINTGUEST SUITE TRIM, VALENCE, INTERIOR DOORS, BACK OF HOUSESHERWIN-WILLIAMSPRO-MAR 200 ZERO VOC SEMI-GLOSS SW7042SHOJI WHITE SEMI-GLOSS MIN 1 COAT PRIMER, 2 COATS PAINT FINISH SPEC CHOICES
PT-01 PAINTCEILINGS THROUGOUTSHERWIN-WILLIAMSPRO-MAR 200 ZERO VOCSW7005PURE WHITE FLAT MIN 1 COAT PRIMER, 2 COATS PAINT FINISH SPEC CHOICES
PL-06 PLASTIC LAMINATEBLACKWILSONARTPLASTIC LAMINATE1595-38BLACK FINE VELVET FINISH WITH AEON FINISH SPEC CHOICES
PL-05 PLASTIC LAMINATETEXTUREWILSONARTPLASTIC LAMINATE4943-38CLASSIC LINEN FINE VELVET FINISH WITH AEON FINISH SPEC CHOICES
PL-04 PLASTIC LAMINATEDARK WOODWILSONARTPLASTIC LAMINATE7991K-12NEO WALNUT SOFT GRAIN FINISH WITH AEON FINISH SPEC CHOICES
PL-03 PLASTIC LAMINATELIGHT TEXTUREWILSONARTPLASTIC LAMINATE4877K-19GREY MESH LENO WEAVE FINISH WITH AEON FINISH SPEC CHOICES
PL-01 PLASTIC LAMINATELIGHT WOODWILSONARTPLASTIC LAMINATE7967K-12PARK ELM SOFT GRAIN FINISH WITH AEON FINISH SPEC CHOICES
PF-15 PRE-FINISHED DOORSINTERIOR DOORS-MATCH PT-15 FINISH SPEC CHOICES
PF-11 PRE-FINISHED DOORSINTERIOR DOORS-MATCH PT-11 FINISH SPEC CHOICES
PF-11 FIBER REINFORCED POLYMER POOL DOORS-FRP PRE-FINISHED DOORS-MATCH PT-11 FINISH SPEC CHOICES
PF-03 PRE-FINISHED DOORSINTERIOR DOORS-MATCH PT-03 FINISH SPEC CHOICES
PC-E POWDER COATDOORS, LOUVERS, METAL ELEMENTS, EXTERIOR PENETRATIONS-MATCH PT-E EXTERIOR FINISH LEGEND
PC-D POWDER COATDOORS, LOUVERS, METAL ELEMENTS, EXTERIOR PENETRATIONS-MATCH PT-D EXTERIOR FINISH LEGEND
PC-C POWDER COATDOORS, LOUVERS, METAL ELEMENTS, EXTERIOR PENETRATIONS-MATCH PT-C EXTERIOR FINISH LEGEND
PC-B POWDER COATDOORS, LOUVERS, METAL ELEMENTS, EXTERIOR PENETRATIONS-MATCH PT-B EXTERIOR FINISH LEGEND
PC-A POWDER COATDOORS, LOUVERS, METAL ELEMENTS, EXTERIOR PENETRATIONS-MATCH PT-A EXTERIOR FINISH LEGEND
PC-11 POWDER COATDOORS, LOUVERS, METAL ELEMENTS, EXTERIOR PENETRATIONS-MATCH PT-11 FINISH SPEC CHOICES
PC-05 POWDER COATDOORS, LOUVERS, METAL ELEMENTS, EXTERIOR PENETRATIONSTIGER DRYLAC USA, INCSTELLIX BONDED METALLIC49/61120LOW LIGHTS BRONZE FINISH SPEC CHOICES
PC-04 POWDER COATDOORS, LOUVERS, METAL ELEMENTS, EXTERIOR PENETRATIONSTIGER DRYLAC USA, INCSTELLIX BONDED METALLIC49/92880APRX TO RAL 9007- SILVER GLOSS FINISH SPEC CHOICES
PC-03 POWDER COATDOORS, LOUVERS, METAL ELEMENTS, EXTERIOR PENETRATIONS-MATCH PT-03 FINISH SPEC CHOICES
GT-06 GROUTKITCHEN FLOOR AND BASEPER CONTRACTORFINE-TEXTURED FINISHVERIFY WITH ARCHITECT 3/8" (REC)HIGH PERFORMANCE OR EPOXY INCLUDE CLEAR MATTE SEALER QT-10 FINISH SPEC CHOICES
GT-05 GROUTKITCHEN FLOOR AND BASEPER CONTRACTORFINE-TEXTURED FINISHVERIFY WITH ARCHITECT 3/8" (REC)HIGH PERFORMANCE OR EPOXY INCLUDE CLEAR MATTE SEALER QT-9 FINISH SPEC CHOICES
GT-04 GROUTKITCHEN FLOOR AND BASEPER CONTRACTORFINE-TEXTURED FINISHVERIFY WITH ARCHITECT 3/8" (REC)HIGH PERFORMANCE OR EPOXY INCLUDE CLEAR MATTE SEALER QT-8 FINISH SPEC CHOICES
GT-03 GROUTKITCHEN FLOOR AND BASEPER CONTRACTORFINE-TEXTURED FINISHVERIFY WITH ARCHITECT 3/8" (REC)HIGH PERFORMANCE OR EPOXY INCLUDE CLEAR MATTE SEALER QT-7 FINISH SPEC CHOICES
GT-03 GROUTWALL TILELATICRETE INTERNATIONAL90- LIGHT PEWTER 1/8" (REC)HIGH PERFORMANCE OR EPOXY INCLUDE CLEAR MATTE SEALER CT-12 FINISH SPEC CHOICES
GT-02 GROUTWALL TILECUSTOM BUILDING PRODUCTS381- BRIGHT WHITE 1/8" (REC)HIGH PERFORMANCE OR EPOXY INCLUDE CLEAR MATTE SEALER CT-11 FINISH SPEC CHOICES
GT-01 GROUTFLOOR TILE AND BASELATICRETE INTERNATIONAL90- LIGHT PEWTER 3/16" (REC)HIGH PERFORMANCE OR EPOXY INCLUDE CLEAR MATTE SEALER CT-01, CT-10 FINISH SPEC CHOICES
FRP-01 FIBER REINFORCED POLYMER KITCHEN WALLSMARLITEPEBBLED FRPP100- WHITE (CLASS A)4' WIDE PANELS TRIM AND SEAL PER MANUFACTURER SILICONE SEALANT- MS 251 MARLITE TRIM PVC MOLDING FINISH SPEC CHOICES
CT-19 CERAMIC TILEPOOL COPINGDAL-TILENOMINEENM10XTP1224C6MT NM10- SAND- MATTE 12"X24"X6CM RETURN -GROUT GT-06 FINISH SPEC CHOICES
CT-18 CERAMIC TILEPOOL DESIGNATION TILES (DEPTH/NO DIVING)DAL-TILENOMINEENM10XTP1224C6MT NM10- SAND- MATTE 12"X24"X6CM RETURN VERIFY W/ REP MAKE IT YOUR OWN- CUSTOM GROUT GT-06 FINISH SPEC CHOICES
CT-17 CERAMIC TILEPOOL WATERLINEDAL-TILECOLOR WHEEL LINEAR GLAZED1049- OCEAN BLUE- CLOSSY 4"X4"X5/16"1/3 OFFSET GUNNITE FINISH SPEC CHOICES
CT-16 CERAMIC TILEPOOL WALL ACCENTDAL-TILECOLOR WHEEL LINEAR GLAZED1049- OCEAN BLUE- GLOSSY 3"X6"X5/16"1/3 OFFSET GROUT GT-06 FINISH SPEC CHOICES
CT-15 CERAMIC TILEPOOL AND POOL BATHROOM WALLSDAL-TILEVOLUME 1.0VL71- DEGREES SILVER- MATTE 12"X24"X5/16"1/3 OFFSET GROUT GT-06 FINISH SPEC CHOICES
CT-14 CERAMIC TILEOUTDOOR KITCHENDAL-TILED-SEGNI- GLAZED PORCEKAIN BIRDSEYESAND BLEND MOUJ- MATTE 8"X8"X3/8"-GROUT GT-05 FINISH SPEC CHOICES
CT-13 CERAMIC TILESUITE SHOP WALL ACCENTDAL-TILECOLOR WHEEL LINEAR GLAZED0190- ARCTIC WHITE- GLOSSY 4"X12"X5/16"STACKED BOND GROUT GT-04 FINISH SPEC CHOICES
CT-12 CERAMIC TILECENTRAL HUB TAP WALL ACCENTDAL-TILECRAFTER- HEXAGON PAPERBLOCK CF20- MATTE 8"X9"X5/16"-GROUT GT-03 FINISH SPEC CHOICES
CT-11 CERAMIC TILEPUBLIC RESTROOM WALLSDAL-TILEMY CITY- SHANGHAITEMPLE LIMESTONE- MATTE SH30 12"X24"X5/16"STACKED BOND GROUT GT-02 FINISH SPEC CHOICES
CT-10.1 CERAMIC TILE BASEPUBLIC SPACE FLOOR BASEDAL-TILEVOLUME 1.0VL71- DEGREES SILVER- MATTE 4"X24"X5/16"1/3 OFFSET GROUT GT-01 FINISH SPEC CHOICES
CT-10 CERAMIC TILEPUBLIC SPACE FLOORDAL-TILEVOLUME 1.0VL71- DEGREES SILVER- MATTE 12"X24"X5/16"1/3 OFFSET GROUT GT-01 (GT-06 @ POOL) FINISH SPEC CHOICES
CT-01.1 CERAMIC TILE BASEGUEST BATHROOM FLOOR BASEDAL-TILEVOLUME 1.0VL71- DEGREES SILVER- MATTE 4"X24"X5/16"1/3 OFFSET GROUT GT-01 FINISH SPEC CHOICES
CT-01 CERAMIC TILEGUEST BATHROOM FLOORDAL-TILEVOLUME 1.0VL71- DEGREES SILVER- MATTE 12"X24"X5/16"1/3 OFFSET GROUT GT-01 FINISH SPEC CHOICES
CS-01 SEALED CONCRETE TOPPER INTERIOR FLOORS AT BOH SPACES
CPT-14 CARPET TILEBACK OF HOUSETARKETTSUBSTANCE11449PURE PARCHMENT 18"X36"VERTICAL ASHLAR FLEX-AIRE MODULAR CUSHION TRANSITION STRIP TS-02, TS-03 FINISH SPEC CHOICES
CPT-13 CARPET TILEMEETING ROOMTARKETTHOMEWOOD SUITES CUSTOMHS63TC.185 24"X24"VERTICAL ASHLAR FLEX-AIRE MODULAR CUSHION TRANSITION STRIP TS-02 FINISH SPEC CHOICES
CPT-12 CARPET TILECENTRAL HUB INSET (CENTER AREA)TARKETTHOMEWOOD SUITES CUSTOMHS57T527 18"X36"VERTICAL ASHLAR FLEX-AIRE MODULAR CUSHION TRANSITION STRIP TS-02 FINISH SPEC CHOICES
CPT-11 CARPET TILECENTRAL HUB INSET (SOCIAL NOOK AND LIVING ROOM AREA)TARKETTHOMEWOOD SUITES CUSTOMHL49T430 18"X36"ASHLAR FLEX-AIRE MODULAR CUSHION TRANSITION STRIP TS-02 FINISH SPEC CHOICES
CPT-10 CARPET TILEGUEST AND PUBLIC CORRIDORSTARKETTHOMEWOOD SUITES CUSTOMHS43T243 18"X36"ASHLAR FLEX-AIRE MODULAR CUSHION TRANSITION STRIP TS-02 FINISH SPEC CHOICES
CPT-02 CARPET TILEGUEST INSERT LIVING ROOMTARKETTHOMEWOOD SUITES CUSTOMHS23T230 18"X36"VERTICAL ASHLAR FLEX-AIRE MODULAR CUSHION TRANSITION STRIP TS-01 FINISH SPEC CHOICES
CPT-01 CARPET TILEGUEST BEDROOMTARKETTHOMEWOOD SUITES CUSTOMHS51T130 18"X36"HERRINGBONE FLEX-AIRE MODULAR CUSHION TRANSITION STRIP TS-01 FINISH SPEC CHOICES
CG-15 CORNER GUARDPUBLIC RESTROOMINPROTAPE-ON CORNER GUARD103- WHITE SAND WC-15 FINISH SPEC CHOICES
CG-14 CORNER GUARDGUEST LAUNDRYINPROTAPE-ON CORNER GUARD283- STERLING WC-14 FINISH SPEC CHOICES
CG-13 CORNER GUARDFITNESSINPROTAPE-ON CORNER GUARD256- CASTLE WC-13 FINISH SPEC CHOICES
CG-12 CORNER GUARDCENTRAL HUBINPROTAPE-ON CORNER GUARD113- TAUPE WC-12 FINISH SPEC CHOICES
CG-11 CORNER GUARDGUEST CORRIDOR DOOR DROP, CENTRAL HUB ACCENT, MEETING ROOM ACCENT INPROTAPE-ON CORNER GUARD186- MERLOT WC-11 FINISH SPEC CHOICES
CG-10 CORNER GUARDGUEST CORRIDOR AND MEETING ROOM MAININPROTAPE-ON CORNER GUARD119- PEPPERMINT WC-10 FINISH SPEC CHOICES
CG-02 CORNER GUARDGUEST SUITE BATHROOM (TOILET AREA)INPROTAPE-ON CORNER GUARD125- ENGLISH GREEN WC-02 FINISH SPEC CHOICES
CG-01 CORNER GUARDGUEST SUITE, BATHROOM (DRESSING AREA)INPROTAPE-ON CORNER GUARD154- CLAM SHELL WC-01 FINISH SPEC CHOICES
ACT-03 ACOUSTIC CEILING TILE (CL-A2) FOOD PREP CEILINGARMSTRONGOPTIMA HEALTH3114PB-WHWHITE 24"X24"ALUMINUM, CLEAN ROOM 1-1/2" SQUARE LAY-IN 15/16 SPECIFICATION BOOK
ACT-02 ACOUSTIC CEILING TILE (CL-A1) SUITE SHOP CEILINGARMSTRONGLYRA CONCEALED-CHARCOAL GREY (MED-DARK GREY) 24"X24"BEVELED, CONCEALED 15/16"CONCEALED, QUICK KERF SPECIFICATION BOOK
ACT-01 ACOUSTIC CEILING TILE (CL-A) CORRIDOR, LOBBY, BOH CEILINGSARMSTRONGLYRA OR OPTIMA CONCEALED-WHITE 24"X24"BEVELED, CONCEALED 15/16"CONCEALED, QUICK KERF SPECIFICATION BOOK
BRANDPRODUCT NAMEPRODUCT IDCOLOR SIZE ADDITIONAL INFO NOTES ASSOCIATED ELEMENT
TAG TYPELOCATION/DESCRIPTION PRODUCT INFORMATION LOCATION OF INFORMATION
FINISH SCHEDULE
7
H
A-701
2
TAP WALL
SELF-BUSSING AND TRASH
CHILLED COUNTER
0' - 6"2' - 0"0' - 3"
4' - 2 1/4"
3/4" ENGINEERED STONE ON PLYWOOD SUBSTRATE
0' - 3"
1
A-702
2
A-702
LINE OF SHELF ABOVE
A-701
3
LINE OF SHELF ABOVE
6' - 0"0' - 2 1/2"3' - 6 1/2"0' - 3"10 EQ. PANELS
17' - 2 1/2"
3/4" ENGINEERED STONE ON PLYWOOD SUBSTRATE
PL-01, TYP. LAMINATE OVER PLYWOOD SUBSTRATE
LAMINATE OVER PLYWOOD SUBSTRATE CABINET DOOR PANELS
0' - 3"0' - 3"0' - 4"4' - 2 1/4"
2' - 6"
2' - 6"2' - 5 1/2"0' - 5"0' - 6 1/4"0' - 1 3/4"3' - 7"3' - 6"4' - 0"4' - 9"10' - 0"PL-01PL-01
PL-01
CT-12
PL-03
K-55
K-55.1
K-56
4
A-701 2' - 0"4
A-701
0' - 7 1/4"0' - 9"2' - 6"
FLIP-DOWN HINGED DOOR WITH MAGNETIC CATCH
2' - 0"
1' - 11 3/4"
0' - 7 1/4"0' - 9"
0' - 6 3/4"6 1/4"5"2' - 5"0' - 0 1/2"3' - 7"BUSSING TUB BY OTHERS
TRASH RECEPTACLE BY OTHERS
CABINET DOOR
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216MILLWORK DETAILS-LOBBY TAP WALL
A-701
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
1" = 1'-0" Reference: 1 / A-431
1TAP WALL AND BREAKFAST BAR PLAN
East Wall in Lobby- Tap Wall and Breakfast Bar (Room 121)
1" = 1'-0" Reference: 2 / A-432
2TAP WALL AND BREAKFAST BAR ELEVATION
East Wall in Lobby- Tap Wall and Breakfast Bar (Room 121)
1" = 1'-0" Reference: 1 / A-431
3 SELF BUSSING AND TRASH PLAN
North Wall and Tap Wall in Lobby (Room 121)
1" = 1'-0" Reference: 2 / A-701
4 SELF-BUSSING AND TRASH SECTION
North Wall and Tap Wall in Lobby (Room 121)
0'6" 1'2'
SCALE: 1" = 1'-0"
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
Revision Schedule
Number Description Date
8
LOCKERS
5' - 0"A-702
4
5
A-702
2' - 3 1/4"2' - 8 3/4"2' - 6 1/4"2' - 6 1/4"2' - 6 1/4"2' - 6 1/4"2' - 6 1/4"7' - 11 1/2"LAMINATE ON PLYWOOD SUBSTRATE ON ALL EXPOSED SURFACES
COORDINATE WITH FABRICATOR AND DOOR HARWARE SUPPLIER TO PROVIDE LOCKER HARDWARE PER BRAND STANDARDS
2' - 8 1/2"
0' - 3"0' - 4"7' - 5"0' - 2 1/2"7' - 11 1/2"1/2"3"3' - 6 1/2"2 1/2"1 1/2"2' - 10"2' - 4 1/4"4"2' - 0 1/2"
LAMINATE OVER 3/4" PLYWOOD SUBSTRATE
LAMINATE SURROUND BEYOND
TV AND MOUNT BY OTHERS
2 CM ENGINEERED STONE ON 3/4" PLYWOOD SUBSTRATE
LAMINATE OVER 3/4" PLYWOOD SUBSTRATE
2 CM ENGINEERED STONE ON 3/4" PLYWOOD SUBSTRATE
TAPS AND WALL BEYOND
2 CM ENGINEERED STONE ON 3/4" MDF SUBSTRATE
UNDER-COUNTER COOLER
LOCKABLE LAMINATE CABINET DOOR PANEL
LAMINATE OVER PLYWOOD SUBSTRATE
3"3' - 2"1' - 2 1/2"
3"4"2' - 3"0' - 3"2' - 10"0' - 10"3"1/2"LAMINATE OVER 3/4" PLYWOOD SUBSTRATE
LAMINATE SURROUND BEYOND
LINEAR LED
TILE BACKSPLASH
LAMINATE SURROUND BEYOND
TAP
DISPLAY SCREEN
2 CM ENGINEERED STONE ON 3/4" PLYWOOD SUBSTRATE
RECESSED STAINLESS STEEL DRIP TRAY - CONNECT TO FLOOR DRAIN COORDINATE CUTOUTS IN MILLWORK FOR CONNECTIVITY
LOCKABLE LAMINATE CABINET DOOR PANEL
LAMINATE OVER PLYWOOD SUBSTRATE
FLOOR DRAIN3' - 2"3' - 9"737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216MILLWORK DETAILS-LOBBY AND GUESTSTORAGE
A-702
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
1" = 1'-0" Reference: 1 / A-431
3GUEST STORAGE PLAN
Room 118
1" = 1'-0" Reference: 3 / A-702
4 GUEST STORAGE ELEVATION
Room 118
1" = 1'-0" Reference: 9 / A-433
5 GUEST STORAGE SECTION
Room 118
1" = 1'-0" Reference: 1 / A-701
1BREAKFAST BAR SECTION
East Wall in Lobby- Tap Wall and Breakfast Bar (Room 121) 1" = 1'-0" Reference: 1 / A-701
2TAP WALL SECTION
East Wall in Lobby- Tap Wall and Breakfast Bar (Room 121)
0'6" 1'2'
SCALE: 1" = 1'-0"
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
Revision Schedule
Number Description Date
8
HA-703
2
3
A-703
4
A-703
Typ1' - 10"2' - 0"0' - 3 1/4"5' - 6"
1' - 8"3' - 7 1/4"
0' - 2 3/4"1' - 5 3/4"0' - 2"0' - 3 1/4"
SS-01: 2 CM ENGINEERED STONE ON 3/4" PLYWOOD SUBSTRATE
REMOVABLE BUSSING TUB, BY OTHERS
WALL COVERING
SS-01: 2 CM ENGINEERED STONE BACKSPLASH
ø 0' - 10"0' - 7"0' - 5"0' - 10"0' - 5"0' - 4"2' - 4 1/2"0' - 1 1/2"3' - 3 1/2"0' - 2 1/2"0' - 4"SS-01: 2 CM ENGINEERED STONE ON 3/4" PLYWOOD SUBSTRATE
SS-01: 2 CM ENGINEERED STONE BACKSPLASH ON 3/4" PLYWOOD SUBSTRATE
WALL COVERING
LAMINATE ON PLYWOOD SUBSTRATE
CONTINUOUS RECESSED LIGHTING WITH CONCEALMENT ANGLE
WALL COVERING
PLASTIC LAMINATE PANEL BEYOND
LAMINATE ON PLYWOOD SUBSTRATE
BLOCKING BEHIND GYP. WALL
CONTINUOUS CONCEALED LED TAPE LIGHT WITH DIFFUSER
PLASTIC LAMINATE PANEL BEYOND
WALL COVERING
2 CM ENGINEERED STONE ON 3/4" PLYWOOD SUBSTRATE
2 CM ENGINEERED STONE BACKSPLASH
REMOVABLE BUSSING TUB
0' - 4"2' - 4 1/2"0' - 1 1/2"0' - 6"0' - 4"3' - 3 1/2"0' - 2 1/2"1' - 6 1/2"VERIFY ACTUAL0' - 3"0' - 0 1/2"2' - 0 3/4"
LAMINATE ON PLYWOOD SUBSTRATE OPERABLE CABINET DOOR; PROVIDE TOUCH LATCH HARDWARE
CONTINUOUS RECESSED LIGHTING WITH CONCEALMENT ANGLE
WALL COVERING
PLASTIC LAMINATE PANEL BEYOND
LAMINATE ON PLYWOOD SUBSTRATE
BLOCKING BEHIND GYP. WALL
CONTINUOUS CONCEALED LED TAPE LIGHT WITH DIFFUSER
PLASTIC LAMINATE PANEL BEYOND
WALL COVERING
2 CM ENGINEERED STONE ON 3/4" PLYWOOD SUBSTRATE W/ MATCHING BACKSPLASH
STAINLESS STEEL LAMINATE COLLAR
0' - 4"2' - 4 1/2"0' - 1 1/2"0' - 4"3' - 3 1/2"0' - 2 1/2"1' - 6 1/2"VERIFY ACTUAL0' - 3"0' - 0 1/2"2' - 0 3/4"
0' - 10"
TRASH
LAMINATE ON PLYWOOD SUBSTRATE OPERABLE CABINET DOOR; PROVIDE TOUCH LATCH HARDWARE
TOE KICK ATTACHED TO DOOR
7
A-703
6
2' - 10 3/4"5' - 0"
2' - 10 3/4"2' - 1"R 0' - 5"R 0' - 5"1' - 0"1' - 0"1' - 0"WATER STATION
7
A-703
Typ8
A-703
9
A-703
SHAFT
2 CM ENGINEERED STONE ON 3/4" PLYWOOD SUBSTRATE
0' - 4"4' - 2"2 CM ENGINEERED STONE ON 3/4" PLYWOOD SUBSTRATE
2 CM ENGINEERED STONE BACKSPLASH
WATER STATION
TOWEL SHELF
TOWEL SHELF
TRASH/TOWEL BINTRASH/TOWEL BIN
2' - 2"
0' - 3"
1/2"4"2' - 5 1/4"2' - 10"7' - 2"4' - 1 1/2"2"1/2"LAMINATE BEYOND
WALL COVERING AT BACK WALL
2 CM ENGINEERED STONE ON 3/4" PLYWOOD SUBSTRATE0' - 4"LAMINATE ON PLYWOOD SUBSTRATE ON ALL EXPOSED SURFACES
LOCKABLE LAMINATE CABINET DOOR PANEL
0' - 7"0' - 10" 0' - 7"
2' - 0"
TRASH/TOWEL BIN
2' - 2"
2' - 0"
0' - 3"
1/2"0' - 4"2' - 5 1/4"2' - 10"7' - 2"4' - 1 1/2"2"1/2"EQEQLAMINATE BEYOND
WALL COVERING AT BACK WALL
SS-01: 2 CM ENGINEERED STONE ON 3/4" PLYWOOD SUBSTRATE
LAMINATE ON PLYWOOD SUBSTRATE ON ALL EXPOSED SURFACES0' - 4"TOWEL SHELF
TOWEL SHELF 2' - 3"WALLCOVERING ON GYP WALL
RECESSED BOTTLE FILLING STATION
BASE AS SCHEDULED
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216MILLWORK DETAILS-FITNESS AND LOBBY
A-703
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
1" = 1'-0" Reference: 1 / A-431
1TRASH AND BUSSING PLAN
In Public Corridor East of Lobby
1" = 1'-0" Reference: 1 / A-703
2TRASH AND BUSSING ELEVATION
In Public Corridor East of Lobby
1" = 1'-0" Reference: 1 / A-703
3 TRASH AND BUSSING SECTION @ BINS
In Public Corridor East of Lobby
1" = 1'-0" Reference: 1 / A-703
4 TRASH AND BUSSING SECTION @ TRASH
In Public Corridor East of Lobby
1" = 1'-0" Reference: 9 / A-435
5FITNESS NICHE PLAN
Room 114
1" = 1'-0" Reference: 5 / A-703
6FITNESS NICHE ELEVATION
Room 114
1" = 1'-0" Reference: 6 / A-435
7FITNESS NICHE AT TOWEL/TRASH BIN
Room 114
1" = 1'-0" Reference: 6 / A-435
8 FITNESS NICHE AT TOWEL SHELVES
Room 114
1" = 1'-0" Reference: 6 / A-435
9 FITNESS WATER STATION SECTION
Room 114
0'6" 1'2'
SCALE: 1" = 1'-0"
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
Revision Schedule
Number Description Date
6
A-704
6
A-704
9
A-704
9
A-704
FF&E VANITY MIRROR
2 CM BACKSPLASH FINISH TO MATCH COUNTERTOP
2 CM ENGINEERED STONE COUNTERTOP SURFACE, STRAIGHT PROFILE WITH EASED EDGE
1/4" REVEAL
LAMINATE OVER 3/4" PLYWOOD
PROVIDE ADDITIONAL SUPPORT FOR COUNTER BEHIND DRYWALL
2' - 0"
INTERNAL BRACING FOR COUNTER RE DETAIL ????0' - 4"8" MIN
1/2"9" MIN2' - 3" MIN4 3/4"2"2' - 10" MAX3' - 4" MAX TO BOTTOM OF REFLECTIVE SURFACE0' - 4"2"2' - 3" MIN2' - 10" MIN0' - 9" MIN8" MIN
1/2"
2' - 0"
FF&E ARTWORK
2 CM BACKSPLASH FINISH TO MATCH COUNTERTOP
2 CM ENGINEERED STONE COUNTERTOP SURFACE, STRAIGHT PROFILE WITH EASED EDGE
INTERNAL BRACING FOR COUNTER RE DETAIL ????
1/4" REVEAL
CUSTOM GRADE CABINET MILLWORK
PROVIDE ADDITIONAL SUPPORT FOR COUNTER BEHIND DRYWALL0' - 11" MIN4 3/4"7' - 1"0' - 6"
2' - 10"
0' - 3"
BACK LIT METAL SIGNAGE ON STANDOFFS
LAMINATE ON 3/4" PLYWOOD SUBSTRATE
PAINT
LAMINATE PANEL
GRAB AND GO
AFF
11'-4"
AFF
10'-2"2 1/2"3' - 7 1/2"1' - 0 1/2"2 1/2"1' - 0 1/2"2 1/2"6' - 4"1' - 3"
WALL COVERING
LAMINATE ON PLYWOOD SUBSTRATE
BLOCKING BEHIND GYP. WALL
FFE PRINTER CASEGOOD AS SCHEDULED
PAINTED WOOD BASE
6' - 10 1/2"
GRAB AND GOFREEZER
2' - 10"0' - 10 1/2"(2'-5")RE EQUIPMENT REQUIREMENTS2"(4'-11/2") RE EQUIPMENT REQUIREMENTS 2' - 0 1/4"
LAMINATE SEAM
MITERED CORNER
LAMINATE OVER PLYWOOD, TYP.
1" = 1'-0"8PUBLIC RESTROOM SECTION @ VANITY
Rooms 116 & 118
1" = 1'-0"10PUBLIC RESTROOM SECTION @ CHANGING
Rooms 116 & 118
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216MILLWORK DETAILS-LOBBY AND PUBLIC
A-704
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
0'6" 1'2'
SCALE: 1" = 1'-0"
1" = 1'-0" Reference: 8 / A-432
1LOBBY WATER ELEVATION
South Wall in Lobby (Room 121)
1" = 1'-0" Reference: 1 / A-431
2LOBBY WATER PLAN
South Wall in Lobby (Room 121)
1" = 1'-0" Reference: 1 / A-431
3ICE/WATER PLAN
Room 118A
1" = 1'-0" Reference: 11 / A-433
4ICE/WATER ELEVATION
Room 118A
1" = 1'-0" Reference: 5 / A-432
5 GRAB AND GO NICHE SECTION
East Wall in Lobby- Suite Shop (Room 121)
1" = 1'-0" Reference: 1 / A-704
6LOBBY WATER SECTION
South Wall in Lobby (Room 121)
1" = 1'-0" Reference: 5 / A-432
7 LIVING ROOM SECTION
East Wall in Lobby- Suite Shop (Room 121)
1" = 1'-0"9ICE/WATER SECTION
1" = 1'-0" Reference: 1 / A-431
11 GRAB AND GO PLAN
East Wall in Lobby- Suite Shop (Room 121)
1" = 1'-0"12 CENTRAL HUB CHECK IN COOLER PLAN
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
Revision Schedule
Number Description Date
5
2' - 1"1' - 4 1/2"2' - 5 1/2"4' - 3"
A-705
1
R 0' -
5
"1' - 1 3/4"MICROWAVE
4
A-705
5
A-705
6
A-705
MICROWAVE1' - 0 1/2"1' - 3"1' - 5 1/2"2' - 10"6' - 7"5' - 0"
3' - 0"PLASTIC LAMINATE ON 3/4" PLYWOOD SUBSTRATE
FLOATING LAMINATE SHELF
DISHWASHER
PROVIDE MILLWORK PANEL COMPLIANT WITH ADA TO SCREEN GARBAGE DISPOSAL, PLUMBING & SINK(LAMINATE OVER 3/4" PLYWOOD SUBSTRATE)
11" MIN
9" MIN2' - 1"2' - 3" MIN0' - 5 1/2"2' - 10" MAX6' - 7"8" MIN
4"
TILE BACKSPLASH
PLASTIC LAMINATE ON 3/4" PLYWOOD SUBSTRATE
PROVIDE MILLWORK PANEL COMPLIANT WITH ADA TO SCREEN GARBAGE DISPOSAL, PLUMBING & SINK(LAMINATE OVER 3/4" PLYWOOD SUBSTRATE)
FINISHED SIDE OF BASE CABINET BEYOND
BASE AS SCHEDULE
0' - 10" 3"2' - 6"2' - 10"2' - 10"6' - 7"LAMINATE OVER 3/4" PLYWOOD SUBSTRATE (ALL EXPOSED EDGES)
BLOCKING BEHIND GYP. WALL
TILE BACKSPLASH
PLASTIC LAMINATE ON 3/4" MDF SUBSTRATE
MICROWAVE
DISHWASHER
2' - 1"
3/4"
3" 4"2' - 5 1/4"3/4"2' - 10"1' - 3"0' - 3"1' - 0" 0' - 3"6' - 7"0' - 10"
2' - 0 1/2"
REFER TO DETAIL ???
LAMINATE OVER 3/4" PLYWOOD SUBSTRATE (ALL EXPOSED EDGES)
BLOCKING BEHIND GYP. WALL
TILE BACKSPLASH
PLASTIC LAMINATE ON 3/4" MDF SUBSTRATE
FLOATING LAMINATE SHELF
STAINLESS STEEL LAMINATE COLLAR
CABINET DOOR LAMINATE OVER 3/4" PLYWOOD SUBSTRATE
0' - 10"
TRASH 0' - 4"0' - 2 1/2"2' - 10"3' - 0"
BACKSPLASH FINISH TO MATCH COUNTERTOP
LAMINATE ON PLYWOOD SUBSTRATE ON ALL EXPOSED SURFACES
HIDDEN METAL CANTILEVERED SUPPORT
IN WALL ∠2" X 1/2" X 3/16" HIDDEN FLAT BRACKET PAINT TO MATCH COUNTER CONTRACTOR TO ENGINEER SUPPORT
LAMINATE PANEL BEYOND
PAINTED METAL BASE
A-705
11
0' - 4"0' - 2 1/2"3' - 6 1/2"3' - 0"
LAMINATE ON PLYWOOD SUBSTRATE ON ALL EXPOSED SURFACES
HIDDEN METAL CANTILEVERED SUPPORT
IN WALL ∠2" X 1/2" X 3/16" HIDDEN FLAT BRACKET PAINT TO MATCH COUNTER CONTRACTOR TO ENGINEER SUPPORT
LAMINATE PANEL BEYOND
PAINTED METAL BASE
WASHER/DRYER
TOP∠1 1/2 X 1 1/2 X3/16
EDGE CONTINUOUS ∠1 1/2 X 1 1/2 X3/16
WALL∠2 1/2 X 2 1/2 X3/16 W/ 1/2"
DIA BOLTS THROUGH WD BLOCKING AND STUD FRAMING BEHIND GYP BD1' - 6"1 1/2"1
1
/
2
"
1/4"
1 1/2"
REF. RICHELIEU CONTEMPORARY PULL 66755
METALREF.
T
O
EL
E
V
A
TI
O
N F
O
R
C
U
ST
O
M
P
ULL L
E
N
G
T
H
REF. RICHELIEU CONTEMPORARY PULL 66755
METAL
2' - 10"4"2 5/8"FROSTED ACRYLIC
LIGHTING AS SPECIFIED
FURNITURE AS SPECIFIED
POWER UNIT
WALLCOVERING AS SCHEDULED
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216MILLWORK DETAILS-EMPLOYEE ANDLAUNDRY LOUNGE
A-705
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
1" = 1'-0" Reference: 9 / A-435
2EMPLOYEE ROOM KITCHEN PLAN
Room 110
1" = 1'-0" Reference: 2 / A-705
1EMPLOYEE ROOM KITCHEN ELEVATION
Room 110
1" = 1'-0" Reference: 2 / A-705
4EMPLOYEE ROOM KITCHEN SECTION @ SINK
Room 110
1" = 1'-0" Reference: 2 / A-705
5EMPLOYEE ROOM KITCHEN SECTION @ DISHWASHER
Room 110
1" = 1'-0" Reference: 2 / A-705
6EMPLOYEE ROOM KITCHEN SECTION @ TRASH
Room 110
0'6" 1'2'
SCALE: 1" = 1'-0"
1" = 1'-0" Reference: 13 / A-435
3 LAUNDRY LOUNGE FOLDING TABLE
Room 112
1" = 1'-0" Reference: 13 / A-435
7 LAUNDRY LOUNGE COUNTER
Room 112
1" = 1'-0" Reference: 3 / A-705
11 BRACING DETAIL
3" = 1'-0"10UPPER CABINET PULL DETAIL
3" = 1'-0"9LOWER CABINET PULL DETAIL
1" = 1'-0"8CENTRAL HUB BANQUETTE LIGHT
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
Revision Schedule
Number Description Date
8
A-7062
1' - 7 1/2"1' - 1 1/2"7' - 4 1/2"1' - 1 1/2"1' - 7 1/2"9' - 7 1/2"1' - 1 1/2"0' - 10"0' - 5 3/4"5' - 1 3/4"1' - 8 3/4"0' - 8 1/2"
2' - 5 1/4"7' - 7"0' - 10 1/2"0' - 4 3/4"A-706
4
A-706
3
0' - 8 1/2"4' - 1"0' - 1"0' - 11"1' - 1 1/2"2' - 0 3/4"0' - 4 3/4"5' - 6 3/4"2' - 6"
0' - 11"1' - 1 1/2"2' - 0 3/4"0' - 7 3/4"4' - 9 1/2"0' - 1"3' - 1"0' - 8 3/4"R 1
'
-
6
"
R 1' - 6"R 1' - 6"R
1
'
-
6
"
1' - 1 3/4"5' - 0"2' - 0 1/2"0' - 8 1/2"
1' - 3 1/2"0' - 10 3/4"A-7065
1
A-707
2
A-707
5
A-707
Typ
6
A-707
Typ
7
A-707
8
A-707
2 CM ENINEERED STONE COUNTER TOP
2 CM ENINEERED STONE COUNTER TOP
9
A-707
3
A-707
4
A-707
2' - 11"0' - 8"0' - 4"3' - 7"2
A-707
LAMINATE FINISH ON 3/4" PLYWOOD
2 CM ENGINEERED STONE COUNTER TOP
3
A-707 0' - 6"0' - 9 1/4" 0' - 9 1/4" 0' - 10 1/2" 0' - 8"0' - 4"3' - 7"1
A-707
OPEN SHELVES,LAMINATE FINISH ON 3/4" PLYWOOD
ACRYLIC RAILING
2 CM ENGINEERED STONE COUNTER TOP
4
A-707
0' - 4"0' - 8"0' - 10 1/2"0' - 9 1/4"0' - 9 1/4"0' - 6"2' - 11"3' - 7"1
A-707
OPEN SHELVES,LAMINATE FINISH ON 3/4" PLYWOOD
ACRYLIC RAILING
2 CM ENGINEERED STONE COUNTER TOP
2 CM ENGINEERED STONE COUNTER TOP
LAMINATE FINISH ON 3/4" PLYWOOD
4
A-707
0' - 4"0' - 10 1/2"0' - 9 1/4"0' - 9 1/4"0' - 6"2' - 11"0' - 8"2
A-707OPEN SHELVES,LAMINATE FINISH ON 3/4" PLYWOOD
2 CM ENGINEERED STONE COUNTER TOP
ACRYLIC RAILING
ACRYLIC RAILING
OPEN SHELVES,LAMINATE FINISH ON 3/4" PLYWOOD
0' - 8"0' - 10 1/2"0' - 9 1/4"0' - 9 1/4"0' - 6"3
A-707
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216MILLWORK DETAILS-RECEPTION DESK PLANAND OUTSIDEELEVATIONS
A-706
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
1" = 1'-0"1Reception Desk Detailed Plan
1" = 1'-0"2Front Desk Det. Front Elevation
1" = 1'-0"3 Front Desk Det. Left Side Elevation
1" = 1'-0"4 Front Desk Det. Right Side Elevation
1" = 1'-0"5Front Desk Det. Rear Elevation 0'6" 1'2'
SCALE: 1" = 1'-0"
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
Revision Schedule
Number Description Date
0' - 8"0' - 10 1/2"0' - 9 1/4"0' - 9 1/4"0' - 6"2' - 11"0' - 8"0' - 10 1/2"0' - 9 1/4"0' - 9 1/4"0' - 6"2' - 0 1/2"2 CM ENGINEERED STONE COUNTER TOP
SPACE FOR COMPUTERSPACE FOR COMPUTER
OPENOPEN
SPACE FOR PRINTER
LAMINATE FINISH ON 3/4" PLYWOOD
LAMINATE FINISH ON 3/4" PLYWOOD2 CM ENGINEERED STONE COUNTER TOP
LAMINATE FINISH ON 3/4" PLYWOOD
3' - 7"0' - 8"SPACE FOR PRINTER
0' - 4"2CM ENGINEERED STONE COUNTER
0' - 4"0' - 3"0' - 3"3' - 7"1' - 1 1/2"
1' - 6 1/2"2 1/2"METAL BASE TO BE REMOVABLE FINISH AS SPECIFIED2' - 11"LAMINATE FINISH AS SPECIFIED
1/4" REVEAL TO BE PAINTED TO MATCH LAMINATE
GUEST SIDE
EMPLOYEE SIDE
MITERED CORNER
2CM ENGINEERED STONE COUNTER
3/4" WOOD SUBSTRATE (3) EQ DRAWERS0' - 8"POWER UNIT
0' - 4"
0' - 3"4"0' - 7 1/2"0' - 7 1/2"0' - 7 1/2"0' - 2"2' - 11"2' - 11 3/4"
2CM ENGINEERED STONE COUNTER
FACE OF LAMINATE DOOR AND ENGINEERED STONE TO ALIGNCABINET DOOR TO BE LOCKABLE WITHPULL HARDWARE
UNDER COUNTER LIGHTING
LAMINATE OVER 3/4" PLYWOOD SUBSTRATE (ALL EXPOSED EDGES)
HARDWOOD EDGE- STAINED TO MATCH LAMINATE
ACRYLIC RAIL
GROMMET FOR CORD MANAGEMENTCOORDINATE LOCATION WITH EQUIPMENT
TOE KICK
SHELF
SHELF
SHELF
GUEST SIDE
EMPLOYEE SIDE
1' - 0"ACRYLIC RAIL
MITERED CORNER
0' - 4"0' - 3"
2CM ENGINEERED STONE COUNTER
0' - 4"0' - 3"0' - 3"3' - 7"1' - 1 1/2"
1' - 6 1/2"0' - 2 1/2"METAL BASE TO BE REMOVABLE FINISH AS SPECIFIED2' - 11"TRASH
LAMINATE FINISH AS SPECIFIED
1/4" REVEAL TO BE PAINTED TO MATCH LAMINATE
GUEST SIDE
EMPLOYEE SIDE
MITERED CORNER
2CM ENGINEERED STONE COUNTER
3/4" WOOD SUBSTRATE
GROMMET FOR CORD MANAGEMENTCOORDINATE LOCATION WITH EQUIPMENT
0' - 4"
LAMINATE OVER 3/4" PLYWOOD SUBSTRATE (ALL EXPOSED EDGES)
0' - 3"0' - 4"0' - 3"PRINTER
2CM ENGINEERED STONE COUNTER
UNDER COUNTER LIGHTING
ACRYLIC RAIL
TOE KICK
PULL OUT DRAWER
LAMINATE 3/4" PLYWOOD SUBSTRATE LOCKABLE DRAWER
1"MITERED CORNER
POWER UNIT
2' - 1 3/4"0' - 2 1/2"SHELF
SHELF
SHELF
1' - 1 1/2"
0' - 2 3/4"
1' - 7 1/2"0' - 5"0' - 7 3/4"1' - 5"
GUEST SIDE
EMPLOYEE SIDE
2' - 11"0' - 2"0' - 7 1/2"0' - 1 3/4"0' - 7 1/2"0' - 1 3/4"SHELF
SHELF
SHELF
GUEST SIDE
EMPLOYEE SIDE
0' - 3"4"2"0' - 1 3/4"1 3/4"2"2' - 0 1/2"10 12"0' - 6"0' - 5"
1' - 0"
1' - 5 1/2"
2CM ENGINEERED STONE COUNTER
MITERED CORNER
ACRYLIC RAIL
UNDER COUNTER LIGHTING
LAMINATE OVER 3/4" PLYWOOD SUBSTRATE (ALL EXPOSED EDGES)
HARDWOOD EDGE- STAINED TO MATCH LAMINATE
TOE KICK0' - 8"0' - 2 1/2"0' - 3"3"2"
LAMINATE 3/4" PLYWOOD SUBSTRATE LOCKABLE SWING DOOR
EQEQ2 CM ENGINEERED STONE COUNTER TOP
LAMINATE FINISH ON 3/4" PLYWOOD
2' - 11"0' - 8"3' - 7"2 CM ENGINEERED STONE COUNTER TOP
SPACE FOR PRINTER0' - 10 1/2"0' - 9 1/4"0' - 9 1/4"0' - 6"0' - 8"2' - 11"LAMINATE FINISH ON 3/4" PLYWOOD
2 CM ENGINEERED STONE COUNTER TOP
0' - 8"2' - 11"737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216MILLWORK DETAILS-RECEPTION DESKSECTIONS AND DETAILS
A-707
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
1" = 1'-0"1Front Desk Section -1
1" = 1'-0"2 Front Desk Section - 2
1" = 1'-0"5Front Desk Det. Section 1 1" = 1'-0"7Front Desk Det. Section 3
1" = 1'-0"6Front Desk Det. Section 2 1" = 1'-0"8 Front Desk Det. Section 4
1" = 1'-0"9Front Desk Det. Section 5
1" = 1'-0"3Front Desk Section - 3
1" = 1'-0"4Front Desk Section - 4
0'6" 1'2'
SCALE: 1" = 1'-0"
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
Revision Schedule
Number Description Date
AFF
8'-0"
ALL SURFACES PLASTICLAMINATE OR WOOD TO MATCHPL-01 UNLESS NOTED OTHERWISE
2CM ENGINEERED STONE TOP AND BACK SPLASH
PLASTIC LAMINATE OR WOODVENEER BACK PANEL TOMATCH PL-03
ADJUSTABLE SHELF
PULL HARDWARE FINISH TO MATCHDAYBREAK: PT-04DUSK: PT-05
INTERIOR FINISH TO BE WHITEMELAMINE UNLESS NOTED OTHERWISE
ALL SURFACES PLASTIC LAMINATEOR WOOD TO MATCH PL-01 UNLESSNOTED OTHERWISE3/4"3"
2' - 1"4"5 EQUAL DRAWERS0' - 0 3/4"3'-0" (2'-9 1/2" AT ACCESSIBLE ROOMS)4' - 5 1/4"2' - 8 3/4"1' - 3"1' - 5 1/4"UNDERCABINET LIGHTING
AFF
8'-0"
ALL SURFACES PLASTICLAMINATE OR WOOD TO MATCHPL-01 UNLESS NOTED OTHERWISE
2CM ENGINEERED STONE TOP AND BACK SPLASH
1' - 8"1' - 5 1/2"1 1/2"1' - 0 1/4"1 1/2"1' - 3"
OPEN SHELF
MICRO
COOKTOP
℄
PLASTIC LAMINATE OR WOODVENEER BACK PANEL TOMATCH PL-03
GAP FOR MICROWAVE WIREMANAGEMENT
PULL HARDWARE FINISH TO MATCHDAYBREAK: PT-04DUSK: PT-05
INTERIOR FINISH TO BE WHITEMELAMINE UNLESS NOTED OTHERWISE
ALL SURFACES PLASTIC LAMINATEOR WOOD TO MATCH PL-01 UNLESSNOTED OTHERWISE
ADJUSTABLE SHELF TOMATCH PL-01
1' - 8"
0' - 3"
2' - 1"0' - 4"4' - 5 1/4"3'-0" (2'-9 1/2" AT ACCESSIBLE ROOMS)6"0' - 3"
AFF
8'-0"
ALL SURFACES PLASTICLAMINATE OR WOOD TO MATCHPL-01 UNLESS NOTED OTHERWISE
2CM ENGINEERED STONE TOP AND BACK SPLASH
3"
2' - 1"4"3/4"1' - 5 1/2"1 1/2"1' - 0 1/4"1 1/2"1' - 3"
OPEN SHELF
MICRO
COOKTOP
℄
PLASTIC LAMINATE OR WOODVENEER BACK PANEL TOMATCH PL-03
GAP FOR MICROWAVE WIREMANAGEMENT
PULL HARDWARE FINISH TO MATCHDAYBREAK: PT-04DUSK: PT-05
INTERIOR FINISH TO BE WHITEMELAMINE UNLESS NOTED OTHERWISE
ALL SURFACES PLASTIC LAMINATEOR WOOD TO MATCH PL-01 UNLESSNOTED OTHERWISE2 EQ DRAWERS3'-0" (2'-9 1/2" AT ACCESSIBLE ROOMS)4' - 5 1/4"2' - 8 3/4"1' - 8"
ADJUSTABLE SHELF
AFF
8'-0"
ALL SURFACES PLASTICLAMINATE OR WOOD TO MATCHPL-01 UNLESS NOTED OTHERWISE
2CM ENGINEERED STONE TOP AND BACK SPLASH
3"
2' - 1"4"3 EQUAL DRAWERS3/4"1' - 8"3' - 0"1' - 5 1/4"1' - 5 1/2"1 1/2"1' - 0 1/4"1 1/2"1' - 3"
OPEN SHELF
MICRO
COOKTOP
℄
PLASTIC LAMINATE OR WOODVENEER BACK PANEL TOMATCH PL-03
GAP FOR MICROWAVE WIREMANAGEMENT
PULL HARDWARE FINISH TO MATCHDAYBREAK: PT-04DUSK: PT-05
INTERIOR FINISH TO BE WHITEMELAMINE UNLESS NOTED OTHERWISE
ALL SURFACES PLASTIC LAMINATEOR WOOD TO MATCH PL-01 UNLESSNOTED OTHERWISE
AFF
8'-0"
2' - 1"3'-0" (2'-9 1/2" AT ACCESSIBLE ROOMS)3/4"1/2"4' - 5 1/4"2' - 8 3/4"1' - 3"3/4"ALL SURFACES PLASTICLAMINATE OR WOOD TO MATCHPL-01 UNLESS NOTED OTHERWISE
2CM ENGINEERED STONE TOP AND BACK SPLASH
PLASTIC LAMINATE OR WOODVENEER BACK PANEL TOMATCH PL-03
ADJUSTABLE SHELF
UNDERCABINET LIGHTING
PULL HARDWARE FINISH TO MATCHDAYBREAK: PT-04DUSK: PT-05
GROMMET FOR CORDMANAGEMENT
ALL SURFACES PLASTIC LAMINATEOR WOOD TO MATCH PL-01 UNLESSNOTED OTHERWISE
DW
AFF
8'-0"5' - 10 3/4"1' - 1 3/4"1 1/2"1' - 3"
PLASTIC LAMINATE OR WOODVENEER BACK PANEL TOMATCH PL-03
REMOVABLE PANELPLASTIC LAMINATE ORWOOD TO MATCH PL-01
0' - 3"
2' - 1"0' - 4"3' - 0"4' - 5 1/4"0' - 6"2' - 8 3/4"0' - 1 1/2"1' - 2"0' - 1 1/2"1' - 2 1/4"0' - 1 1/2"1' - 3"
AFF
8'-0"3/4"ALL SURFACES PLASTIC LAMINATEOR WOOD TO MATCH PL-01UNLESS NOTED OTHERWISE
GAP FOR MICROWAVE WIRE MANAGEMENT
2CM ENGINEERED STONE TOP AND BACK SPLASH
PULL HARDWARE FINISH TO MATCHDAYBREAK: PT-04DUSK: PT-05
INTERIOR FINISH TO BE WHITEMELAMINE UNLESS NOTED OTHERWISE
ALL SURFACES PLASTIC LAMINATE OR WOODTO MATCH PL-01 UNLESS NOTED OTHERWISE
NOTE: CONSTRUCTION SHOULD ALWAYS USEA MARINE GRADE PLYWOOD SUBSTRATE
UNDERCABINET LIGHTING
PLASTIC LAMINATE OR WOODVENEER BACK PANEL TOMATCH PL-03
OPEN SHELF
OPEN SHELF
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216MILLWORK DETAILS-GUESTROOM KITCHENS
A-708
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
0'6" 1'2'
SCALE: 1" = 1'-0"
1" = 1'-0"1GR KITCHEN SECTION-5 DRAWER CABINET
1" = 1'-0"2GR KITCHEN SECTION-COOKTOP WITH 1 DRAWER & 1 DOOR
1" = 1'-0"3 GR KITCHEN SECTION-COOKTOP WITH 2 DRAWERS & 1 DOOR
1" = 1'-0"4GR KITCHEN SECTION-COOKTOP WITH 3 DRAWERS
1" = 1'-0"5GR KITCHEN SECTION-DISHWASHER
1" = 1'-0"6GR KITCHEN SECTION-REF
1" = 1'-0"7 GR KITCHEN SECTION-SINK
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
Revision Schedule
Number Description Date
AFF
8'-0"4' - 0" MAX8" MIN
9" MIN11" MIN2' - 9 1/4" MAX1' - 1 1/4"3' - 3 1/2"2' - 3" MIN0' - 5 1/2"0' - 4"10 1/2"1' - 3"
INTERIOR FINISH TO BE WHITE MELAMINEUNLESS NOTED OTHERWISE
PULL HARDWARE FINISH TO MATCHDAYBREAK: PT-04DUSK: PT-05
ALL SURFACES PLASTIC LAMINATEOR WOOD TO MATCH PL-01 UNLESSNOTED OTHERWISE
ADJUSTABLE SHELF TO MATCH PL-01
UNDERCABINET LIGHTING
2CM ENGINEERED STONE TOP ANDBACKSPLASH TO MATCH SS-01
INTERIOR FINISH TO BE WHITEMELAMINE UNLESS NOTED OTHERWISE
REMOVABLE MILLWORK PANEL
VERTICAL PANEL SUPPORT
FINISHED SIDE OF BASE CABINET BEYOND
AFF
8'-0"
ALL SURFACES PLASTIC LAMINATEOR WOOD TO MATCH PL-01UNLESS NOTED OTHERWISE
PLASTIC LAMINATE OR WOODVENEER BACK PANEL TOMATCH PL-03
3/4" MDF W/ WOOD VENEER OPEN CABINET WITH EXPOSED SHELVES (ALL SIDES TO BE FINISHED)
OPEN SHELF
OPEN SHELF
UNDERCABINET LIGHTING
2CM ENGINEERED STONETOP AND BACKSPLASH TOMATCH SS-01
ALL PLUMBING AND EQUIPMENT BELOW THE SINK IN ACCESSIBLE ROOMS MUST BE CONCEALED FROM GUEST VIEW
REMOVABLE MILLWORK PANEL
VERTICAL PANEL SUPPORT
FINISHED SIDE OF BASE CABINET BEYOND
2' - 1"2' - 3" MIN6"2' - 9 1/2" MAX4' - 5 1/4"1 1/2"1' - 2 1/4"1 1/2"1' - 2"1 1/2"11" MIN
9" MIN1' - 3"
AFF
8'-0"
INTERIOR FINISH TO BE WHITE MELAMINEUNLESS NOTED OTHERWISE
PULL HARDWARE FINISH TO MATCHDAYBREAK: PT-04DUSK: PT-05
ALL SURFACES PLASTIC LAMINATEOR WOOD TO MATCH PL-01 UNLESSNOTED OTHERWISE
ADJUSTABLE SHELF TO MATCH PL-01
UNDERCABINET LIGHTING
2' - 9 1/4" MAX0' - 4"10 1/2"1' - 3"1' - 1 1/4"3' - 3 1/2"2CM ENGINEERED STONE TOP ANDBACKSPLASH TO MATCH SS-01
ADA DW
ADA MICRO
4' - 0" MAX2' - 1"
1/2"
AFF
8'-0"
ALL SURFACES PLASTICLAMINATE OR WOOD TO MATCHPL-01 UNLESS NOTED OTHERWISE
2CM ENGINEERED STONE TOP AND BACK SPLASHCOOKTOP
℄
PLASTIC LAMINATE OR WOODVENEER BACK PANEL TOMATCH PL-03
PULL HARDWARE FINISH TO MATCHDAYBREAK: PT-04DUSK: PT-05
ALL SURFACES PLASTIC LAMINATEOR WOOD TO MATCH PL-01 UNLESSNOTED OTHERWISE
ADJUSTABLE SHELF
PULL HARDWARE FINISH TO MATCHDAYBREAK: PT-04DUSK: PT-05
ALL SURFACES PLASTIC LAMINATEOR WOOD TO MATCH PL-01 UNLESSNOTED OTHERWISE
VENT HOOD
3"
2' - 1"4"2'-9 1/2" AT ACCESSIBLE ROOMS6"10"1' - 3"4' - 5 1/4"2' - 2 3/4"0' - 3"
1' - 8"
3"
2' - 5 1/2"4"3 EQUAL DRAWERS3' - 0"1 1/4"2CM ENGINEERED STONE TOP AND BACKSPLASH
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216MILLWORK DETAILS-ACCESSIBLEGUESTROOM KITCHENS
A-709
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
0'6" 1'2'
SCALE: 1" = 1'-0"
1" = 1'-0"2GR KITCHEN SECTION-COUNTER ADA
1" = 1'-0"1GR KITCHEN SECTION-SINK ADA 1" = 1'-0"3 GR KITCHEN SECTION-DISHWASHER ADA 1" = 1'-0"4 GR KITCHEN SECTION-COOKTOP ADA
1" = 1'-0"5GW KITCHEN SECTION-3 DRAWER
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
Revision Schedule
Number Description Date
G
7
2
A-301
E
8
737 BISHOP STREET, SUITE 1860HONOLULU, HI 96813808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisile AvenueSpokane Valley, WA 99216MILLWORK DETAILS-MODIFIED FURNITURE
A-710
FSC PROJECT NO. 21012
BID/PERMIT SET
MAY 31, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-0901
0'6" 1'2'
SCALE: 1" = 1'-0"
1" = 1'-0"1Coffee Station Detail Plan
1" = 1'-0"2ACCESSIBLE GUEST BATH VANITY
1" = 1'-0"3GUEST BATH VANITY
1" = 1'-0"4 MEETING ROOM CREDENZA
EXP.8/23/2025
REGISTEREDARCHITECT
13010
STATE OF WASHINGTONBENJAMIN CHUA CANDARI IV
Revision Schedule
Number Description Date
DESIGN CONDITIONS
LOCATION SPOKANE VALLEY, WA
CLIMATE ZONE 5B (SPOKANE COUNTY)
OUTDOORS COOLING 96°F DB / 64°F WB
HEATING 10°F DB
INDOOR COOLING 75°F
HEATING 72°F
VENTILATION PER IMC/ASHRAE 62.1-2019
ELEVATION 2,400 FT ABOVE SEA LEVEL
GENERAL HVAC NOTES
1. SHEET METAL DUCTWORK AND COMPONENTS INCLUDING HANGING, SEALING, PLENUMS, & ACCESSORIES SHALL BE CONSTRUCTED IN STRICT
ACCORDANCE WITH THE LATEST EDITION OF SMACNA STANDARDS FOR HVAC DUCT CONSTRUCTION, NFPA 90A, & 90B STANDARDS.
2. ALL DUCTWORK OPENINGS SHALL BE COVERED DURING CONSTRUCTION.
3. ALL DAMPERS SHALL BE SET FULLY OPEN PRIOR TO BALANCING.
4. CONTRACTOR TO PROVIDE TRANSITION TO CONNECT TO ALL MECHANICAL EQUIPMENT. PROVIDE FLEXIBLE CONNECTION ON INTAKE AND DISCHARGE
OF ALL MECHANICAL EQUIPMENT.
5. DUCT DIMENSIONS SHOWN ARE INSIDE SHEET METAL DIMENSIONS OR CLEAR OPENING INSIDE LINED DUCT.
6. DRAWINGS ARE DIAGRAMMATIC IN NATURE AND DO NOT ATTEMPT TO SHOW ALL REQUIRED OFFSETS. COORDINATE WITH OTHER TRADES AND
PROVIDE ALL NECESSARY OFFSETS.
7. PROVIDE 1" THICK DUCT LINER IN ALL TRANSFER AIR DUCTWORK UNLESS NOTED OTHERWISE.
8. ALL ELBOWS SHALL BE LONG RADIUS ELBOWS WHEREVER POSSIBLE, OR SHALL HAVE TURNING VANES WHERE INDICATED ON PLANS. NO SQUARE
THROAT OR ZERO RADIUS ELBOWS ALLOWED.
9. ALL DUCT BRANCH CONNECTIONS TO DIFFUSER OR GRILLES, TO OR FROM MAIN DUCTS, SHALL INCLUDE MANUAL VOLUME DAMPERS. ALL SPIN-IN
FITTINGS SHALL BE CONICAL, RECTANGULAR BRANCH DUCT TAKEOFFS SHALL HAVE 45° TAKEOFFS.
10. PROVIDE CONCEALED DAMPER REGULATORS OR ACCESS DOORS FOR ALL MANUAL VOLUME DAMPERS LOCATED THAT ARE INACCESSIBLE. REFER
TO ARCHITECTURAL DRAWINGS FOR CEILING TYPES. ALL FINAL ACCESS DOOR LOCATIONS SHALL BE APPROVED BY ARCHITECT PRIOR TO
INSTALLATION.
11. 24"x24" ACCESS DOORS SHALL BE PROVIDED FOR ALL MECHANICAL EQUIPMENT LOCATED ABOVE GYPSUM BOARD CEILINGS. ALL FINAL ACCESS
DOOR LOCATIONS SHALL BE APPROVED BY ARCHITECT PRIOR TO INSTALLATION.
12. PROVIDE DIFFUSER AND GRILLE FRAMES COMPATIBLE WITH ARCHITECTURAL CEILING TYPES AND COORDINATE LOCATIONS WITH THE
ARCHITECTURAL REFLECTED CEILING PLAN AND ELECTRICAL LIGHTING LAYOUT.
13. ALL DUCTWORK VISIBLE THROUGH RETURN OR SUPPLY GRILLES TO BE PAINTED FLAT BLACK.
14. ALL SUPPLY, RETURN AND EXHAUST AIR DUCTS SHALL HAVE THE TRANSVERSE JOINTS, LONGITUDINAL SEAMS, AND DUCT WALL PENETRATIONS
SEALED AIRTIGHT WITH DUCT SEALANT (SMACNA SEAL CLASS "A").
15. COORDINATE EXACT LOCATIONS OF ALL ROOM THERMOSTATS AND/OR ROOM TEMPERATURE SENSORS WITH ARCHITECT/OWNER PRIOR TO
INSTALLATION.
16. BALANCE AIR SYSTEM TO QUANTITIES SHOWN, AND SUBMIT A COPY OF THE BALANCE REPORT TO THE ENGINEER FOR REVIEW.
GENERAL NOTES
1. CONTRACTOR SHALL SECURE, MAINTAIN, AND PAY FOR ALL REQUIRED PERMITS, LICENSES, AND INSPECTIONS FOR DURATION OF WORK UNLESS
DIRECTED OTHERWISE.
2. ALL WORK SHALL COMPLY WITH THE OWNER'S REQUIREMENTS, AND WITH ALL APPLICABLE STATE AND LOCAL CODES, OR AUTHORITY HAVING
JURISDICTION.
3. SUBSTITUTIONS OF EQUIPMENT OTHER THAN AS SPECIFIED SHALL BE THE COMPLETE RESPONSIBILITY OF THE CONTRACTOR, ANY ADDITIONAL
ELECTRICAL, STRUCTURAL, MECHANICAL, OR ARCHITECTURAL REQUIREMENTS SHALL BE PROVIDED AT NO ADDITIONAL EXPENSE TO THE OWNER.
4. DRAWINGS ARE DIAGRAMMATIC IN NATURE AND DO NOT ATTEMPT TO SHOW ALL REQUIRED OFFSETS. COORDINATE WITH OTHER TRADES AND
PROVIDE ALL NECESSARY OFFSETS. REFER TO ARCHITECTURAL AND STRUCTURAL DRAWINGS FOR CONSTRUCTION DETAILS.
5. REFER TO PROJECT MANUAL (SPECIFICATIONS) FOR ADDITIONAL REQUIREMENTS. PLANS AND SPECIFICATIONS SHALL BE TAKEN TOGETHER.
PROVIDE ALL WORK CALLED FOR IN EITHER. IN CASE OF CONFLICT BETWEEN SPECIFICATIONS AND PLANS THE MORE STRINGENT SHALL APPLY.
6. ALL EQUIPMENT AND MATERIAL ON THE JOB SITE PRIOR TO INSTALLATION SHALL BE COVERED AND PROTECTED FROM RAIN, DIRT, DUST, AND
DAMAGE.
7. VERIFY PHYSICAL DIMENSIONS OF EQUIPMENT TO ENSURE THAT ACCESS CLEARANCES CAN BE MET. COORDINATE FINAL EQUIPMENT LOCATIONS W/
GENERAL CONTRACTOR AND OTHER TRADES TO ALLOW FOR REQUIRED MECHANICAL EQUIPMENT CLEARANCES.
8. PROVIDE AN UNOBSTRUCTED PASSAGEWAY MEASURING NO LESS THAN 36" WIDE BY 80" HIGH FROM DOOR INTO THE SPACE TO SERVICEABLE
MECHANICAL EQUIPMENT. A LEVEL WORKING SPACE MEASURING NO LESS THAN 30" WIDE BY 36" DEEP MUST BE PROVIDED IN FRONT OF CONTROL
SIDE OF EQUIPMENT FOR SERVICING.
9. PROVIDE NEC CODE MINIMUM HORIZONTAL AND VERTICAL WORKING CLEARANCES FOR ALL ELECTRICAL PANELS AND EQUIPMENT. OFFSET
MECHANICAL WORK AS REQUIRED.
10. CONTRACTOR IS RESPONSIBLE FOR VERIFICATION OF INSTALLATION STANDARDS AND CONSTRUCTION CONDITIONS. CONTRACTOR SHALL FIELD
VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS PRIOR TO SHOP FABRICATION AND/OR FIELD INSTALLATION. DISCREPANCIES BETWEEN
EXISTING CONDITIONS AND THE CONSTRUCTION DRAWINGS SHALL BE CALLED TO THE ATTENTION OF THE ENGINEER.
11. ALL MECHANICAL EQUIPMENT, MATERIALS, AND INSTALLATION SHALL BE PROVIDED BY THE CONTRACTOR. ALL EQUIPMENT SHALL BE COMPLETE,
INSTALLED, AND FULLY FUNCTIONAL PRIOR TO FINAL ACCEPTANCE OF THE WORK.
12. INSTALL ALL EQUIPMENT PER MANUFACTURERS RECOMMENDATIONS AND REQUIREMENTS. ANY CONFLICTS BETWEEN THE MANUFACTURERS
DOCUMENTATION AND THE CONTRACT DOCUMENTS SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER.
13. DO NOT ALLOW ANY WORK TO BE COVERED UP OR ENCLOSED UNTIL INSPECTED, TESTED AND APPROVED BY OWNER'S REPRESENTATIVE OR
AUTHORITY HAVING JURISDICTION.
14. MECHANICAL EQUIPMENT SHALL NOT BE USED FOR TEMPORARY HEATING OR COOLING DURING CONSTRUCTION.
15. PIPES AND WIRING IN PLENUM SHALL BE RATED FOR PLENUM USE. PVC, ABS, AND PLASTIC PIPING IS NOT ACCEPTABLE IN PLENUM APPLICATIONS.
16. ALL DETAILS ARE TYPICAL UNLESS NOTED OTHERWISE.
GENERAL PLUMBING NOTES
1. PROVIDE ALL LABOR, MATERIALS, AND EQUIPMENT NECESSARY TO CONSTRUCT A COMPLETE, OPERATIONAL PLUMBING SYSTEM FOR THE ENTIRE
PROJECT AS SHOWN ON THESE DRAWINGS, INCLUDING ALL NECESSARY FEES AND PERMITS.
2. THE ENTIRE INSTALLATION SHALL CONFORM TO THE MOST RECENTLY ADOPTED REQUIREMENTS OF THE PLUMBING CODE, AND ALL OTHER
APPLICABLE CITY, COUNTY, STATE, AND FEDERAL CODES AND REGULATIONS IN EFFECT AT THE DATE OF THE BID. CONFORM TO ANY CODES, RULES,
REGULATIONS AND REQUIREMENTS THAT THE PROJECT OWNER HAS.
3. PRIOR TO FABRICATION AND INSTALLATION, THE CONTRACTOR SHALL COORDINATE THE INSTALLATION OF ALL PLUMBING WORK WITH ALL OTHER
TRADES INCLUDING THE MECHANICAL CONTRACTOR, FIRE PROTECTION CONTRACTOR, ELECTRICAL CONTRACTOR, GENERAL CONTRACTOR, AND
ANY CONTRACTOR HIRED DIRECTLY BY THE OWNER. WHERE CONFLICTS MAY OCCUR, THEY SHALL BE RESOLVED PRIOR TO INSTALLATION.
4. THE WORKING DRAWINGS ARE DIAGRAMMATIC. BECAUSE OF THE SMALL SCALE OF THE DRAWINGS, THEY DO NOT SHOW EVERY OFFSET, BEND OR
ELBOW NECESSARY FOR THE COMPLETE INSTALLATION IN THE SPACE PROVIDED. ALL LOCATIONS FOR PLUMBING EQUIPMENT AND PIPING SHALL BE
CHECKED AND COORDINATED WITH THE ARCHITECTURAL, MECHANICAL, STRUCTURAL AND ELECTRICAL DRAWINGS.
5. ALL EQUIPMENT SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THE EQUIPMENT MANUFACTURER'S RECOMMENDATIONS. PROVIDE ALL
FITTINGS, TRANSITIONS, VALVES, WORKING CLEARANCES, AND OTHER DEVICES AND ACCESSORIES REQUIRED FOR A COMPLETE, WORKABLE
INSTALLATION.
6. PROVIDE PROPER PROVISIONS FOR EXPANSION OR MOVEMENT OF ALL PIPING.
7. PROVIDE WATER HAMMER ARRESTORS (SHOCK ABSORBERS) AT ALL PIPE LOCATIONS WHERE VALVE CLOSURES MAY CAUSE WATER HAMMER OR
RESULT IN EXCESSIVE PIPE VIBRATION OR MOVEMENT. (EXAMPLES INCLUDE FLUSH VALVES, SENSOR FAUCETS, AND WASHING MACHINES).
8. PROVIDE CLEANOUTS AS REQUIRED BY CODE, INCLUDING AT ALL SINKS, URINALS AND END OF RUNS.
GENERAL ABBREVIATIONS
ø ROUND or DIAMETER
AAV AUTOMATIC AIR VENT
ABV ABOVE
AD ACCESS DOOR
AFF ABOVE FINISH FLOOR
AHU AIR HANDLING UNIT
AL ACOUSTIC LINED
AP ACCESS PANEL
APD AIR PRESSURE DROP
ASME AMERICAN SOCIETY OF MECHANICAL
ENGINEERS
AWT AVERAGE WATER TEMPERATURE
BB BASEBOARD
BBD BACKDRAFT DAMPER
BFF BELOW FINISH FLOOR
BHP BRAKE HORSEPOWER
BG BELOW GROUND/GRADE
BTU BRITISH THERMAL UNIT
BTUH BRITISH THERMAL UNITS PER HOUR
C CENTIGRADE
CC COOLING COIL
CD CEILING DIFFUSER
CFM CUBIC FEET PER MINUTE
CG CEILING GRILLE
CI CAST IRON
CLG CEILING
CO CLEANOUT
COG CLEANOUT TO GRADE
CMU CONCRETE MASONRY UNIT
CM CONDENSATE METER
CONC CONCRETE
CONN CONNECT or CONNECTION
CONST CONSTRUCTION
CONT CONTINUATION
(D) DEMOLISH
DB DECIBEL or DRY BULB
DDC DIRECT DIGITAL CONTROL
DIA DIAMETER
DIM DIMENSION
DN DOWN
DOAS DEDICATED OUTDOOR AIR SYSTEM
DPR DAMPER
DPS DIFFERENTIAL PRESSURE SWITCH
DWG DRAWING
(E) EXISTING
EA EACH
EAT ENTERING AIR TEMPERATURE
EF EXHAUST FAN
EG EXHAUST GRILLE
ELEC ELECTRIC or ELECTRICAL
ELEV ELEVATION
EMCS ENERGY MANAGEMENT CONTROL
SYSTEM
ERV ENERGY RECOVERY VENTILATOR
ESP EXTERNAL STATIC PRESSURE
EWT ENTERING WATER TEMPERATURE
EXH EXHAUST
EXST EXISTING
F FAHRENHEIT
FCO FLOOR CLEANOUT
FCU FAN COIL UNIT
FD FLOOR DRAIN
FD FIRE DAMPER
FFD FUNNEL FLOOR DRAIN
FF FINAL FILTER
FLR FLOOR
FPM FEET PER MINUTE
FPS FEET PER SECOND
FS FLOOR SINK
FSD COMBINATION FIRE/SMOKE DAMPER
FT FOOT/FEET
FTR FINNED TUBE RADIATION
FV FACE VELOCITY
GA GAGE or GAUGE
GAL GALLON
GALV GALVANIZED
GPH GALLONS PER HOUR
GPM GALLONS PER MINUTE
GRD GRILLE, REGISTER, OR DIFFUSER
H HEIGHT
HB HOSE BIBB
HD HEAD
HP HORSEPOWER
HRV HEAT RECOVERY VENTILATOR
HTG HEATING
HVAC HEATING, VENTILATION AND
AIR CONDITIONING
HWG HIGH WALL GRILLE
HWR HIGH WALL REGISTER
HZ HERTZ
ID INSIDE DIAMETER
IE INVERT ELEVATION
IN INCH or INCHES
INSUL INSULATION
INV INVERT
KH KICKSPACE HEATER
KW KILOWATT
KWH KILOWATT HOUR
L LENGTH
LAT LEAVING AIR TEMPERATURE
LBS POUNDS
LF LINEAR FOOT/FEET
LVG LEAVING
LWG LOW WALL GRILLE
LWR LOW WALL REGISTER
LWT LEAVING WATER TEMPERATURE
MAX MAXIMUM
MAV MANUAL AIR VENT
MBH 1000 BRITISH THERMAL UNITS
PER HOUR
MCA MINIMUM CIRCUIT AMPACITY
MCC MOTOR CONTROL CENTER
MFR MANUFACTURER
MOP MAXIMUM OVERCURRENT
PROTECTION
MUA MAKEUP AIR UNIT
MIN MINIMUM
MISC MISCELLANEOUS
MTD MOUNTED
MTG MOUNTING
(N) NEW
(NL) NEW LOCATION
N/A NOT APPLICABLE
N/C NORMALLY CLOSED
N/O NORMALLY OPEN
NC NOISE CRITERIA
N.I.C. NOT IN CONTRACT
NPT NATIONAL PIPE THREAD
NTS NOT TO SCALE
OA OUTSIDE AIR
OBD OPPOSED BLADE DAMPER
O/C ON CENTER
OD OUTSIDE DIAMETER
OPNG OPENING
PVC PRESSURE CONTROL VALVE
PD PRESSURE DROP
PH PHASE
PLCS PLACES
POC POINT OF CONNECTION
POUA POINT OF USE ALARM
PRV PRESSURE REDUCING VALVE
PSI POUNDS PER SQUARE INCH
PSIG POUNDS PER SQUARE INCH (GAGE)
(REL) RELOCATE/RELOACTED
RA RETURN AIR
RAG RETURN AIR GRILLE
REQD REQUIRED
R.O. ROUGH OPENING
RPBP REDUCED PRESSURE BACKFLOW
PREVENTER
RPM REVOLUTIONS PER MINUTE
SA SUPPLY AIR
SD SMOKE DETECTOR
SF SUPPLY FAN
SHT SHEET
SIM SIMILAR
SL SOUNDLINING
SP STATIC PRESSURE
SQ SQUARE
SQ FT SQUARE FOOT/FEET
SS STAINLESS STEEL
STD STANDARD
TAB TESTING, ADJUSTING & BALANCING
THK THICK
TP TRAP PRIMER or TEST PLUG
TSP TOTAL STATIC PRESSURE
TYP TYPICAL
TU TERMINAL UNIT
UBC UNIFORM BUILDING CODE
UFC UNIFORM FIRE CODE
UMC UNIFORM MECHANICAL CODE
UPC UNIFORM PLUMBING CODE
UG UNDERGROUND
UH UNIT HEATER
UNO UNLESS NOTED OTHERWISE
VA VALVE
VAC VACUUM
VAV VARIABLE AIR VOLUME
VD VOLUME DAMPER
VEL VELOCITY
VFD VARIABLE FREQUENCY DRIVE
VRF VARIABLE REFRIGERANT FLOW
VTR VENT THRU ROOF
W WIDE
W/ WITH
W/O WITHOUT
WB WET BULB
WC WATER COLUMN
WCO WALL CLEANOUT
WG WATER GAGE
WGE WASTE GAS EVACUATION
WH WALL HYDRANT
WPD WATER PRESSURE DROP
WT WEIGHT
GENERAL LEGEND
THERMOSTAT. ADJACENT NUMBER
INDICATES TERMINAL UNIT CONTROLLED
HUMIDISTAT
SENSOR
CO2 SENSORCO2
T
H
S
PLUMBING FIXTURE TAG, SEE PLUMBING SCHEDULES
NOTES:
XX-X
SPECIFIC TO LOCATION(S) INDICATED.
A. NOTE APPLIES TO ENTIRE SHEET.
EXISTING
NEW
(E)
(N)
EXISTING (THIN)
NEW (MEDIUM)
POINT OF CONNECTION (POC)
1
EXISTING TO BE DEMOLISHED
MECHANICAL EQUIPMENT, SEE MECHANICAL SCHEDULES.XX-X
x
SD DUCT SMOKE DETECTOR
SP DUCT STATIC PRESSURE
LINETYPES:
B
A
A
B
_____________________
DETAIL SYMBOL:
A = IDENTIFYING NUMBER
B = SHEET WHERE DETAIL IS SHOWN
SECTION SYMBOL:
A = IDENTIFYING NUMBER
B = SHEET WHERE DETAIL IS SHOWN
NEW LOCATION(NL)
RELOCATED(REL)
HVAC DUCTWORK LEGEND
DUCTWORK
24x12 S/A
RECTANGULAR DUCT
SIZE (INCHES) FIRST
DIMENSION IS SIDE OF
DUCT SHOWN
DUCT SIZES SHOWN ON DRAWINGS ARE CLEAR INSIDE DIMENSIONS OF DUCT. DUCT SIZE
SHOWN DOES NOT INCLUDE INSULATION OR LINING UNLESS NOTED OTHERWISE. SEE
BELOW FOR DUCT SIZE TAG LEGEND.
DUCT SIZE
DUCT SYSTEM ABBREVIATION
(NOT ALWAYS BE SHOWN)
INSULATED DUCT
SOUND LINED DUCT
24x12ø
FLAT OVAL DUCT
SIZE (INCHES) FIRST
DIMENSION IS SIDE OF
DUCT SHOWN
24ø ROUND DUCT
18ø24x12 CHANGE IN DUCT SIZE
AND/OR SHAPE
SUPPLY AIR (SA)
OUTSIDE AIR (OSA)
RECTANGULAR DUCT
TURNED UP/SECTION
ROUND/FLAT OVAL DUCT
TURNED UP/SECTION
RECTANGULAR DUCT
TURNED DOWN/AWAY
ROUND/FLAT OVAL DUCT
TURNED DOWN/AWAY
RETURN AIR (RA)
RECTANGULAR DUCT
TURNED UP/SECTION
ROUND/FLAT OVAL DUCT
TURNED UP/SECTION
RECTANGULAR DUCT
TURNED DOWN/AWAY
ROUND/FLAT OVAL DUCT
TURNED DOWN/AWAY
EXHAUST AIR (EA)
RECTANGULAR DUCT
TURNED UP/SECTION
ROUND/FLAT OVAL DUCT
TURNED UP/SECTION
RECTANGULAR DUCT
TURNED DOWN/AWAY
ROUND/FLAT OVAL DUCT
TURNED DOWN/AWAY
DAMPERS
VOLUME/BALANCING
DAMPER
FIRE DAMPER (FD)
SMOKE DAMPER (SD)
FIRE/SMOKE DAMPER
(FSD)
BACKDRAFT DAMPER
CONSTANT VOLUME
DAMPER
DUCT SYSTEM ABBREVIATIONS
A
SUPPLY AIRSA
OUTSIDE AIROA
COMBUSTION AIRCA
RETURN AIRRA
TRANSFER AIRTA
EXHAUST AIREA
FLEXIBLE DUCT
DUCT SYMBOLS
DUCT END CAP
DUCT ACCESS DOOR
AD
SUPPLY AIR (SA) OR
OUTSIDE AIR (OA) TERMINAL
RETURN AIR (RA) OR
TRANSFER AIR (TA) TERMINAL
AIR TERMINAL
IDENTIFICATION
EXHAUST AIR (EA) TERMINAL
GRILLE, REGISTER, OR OPEN
DUCT
X
CFM
AIRFLOW DIRECTION
SOUND ATTENUATOR
OR X-CFM
MOTORIZED DAMPER
M
PLUMBING LEGEND
COLD WATER (CW)W SANITARY WASTE
ABOVE GRADE (W)
HOT WATER (HW)
HOT WATER
CIRCULATING (HWC)
140° HOT WATER
(HW)
140° HOT WATER
CIRCULATING (HWC)
140 HW
140 HWC
INDUSTRIAL COLD
WATER (ICW)ICW
TEMPERED WATER
(TW)TW
BGW
SANITARY WASTE
BELOW GRADE
(BGW)
PW PUMPED WASTE
(PW)
OW OILY WASTE (OW)
V VENT - SANITARY (V)
RAD RADON (RAD)
RV RELIEF VENT (RV)
RAIN LEADER (RD)RD
OVERFLOW RAIN
LEADER (ORD)ORDSTORM DRAIN (SD)SD
TRAP PRIMER (TP)TP
NATURAL GAS (G)G
PLUMBING SYMBOLS & FIXTURE TAGS
2" FD-1
4" FCO
4" RD-1
4" COG
4" ORD-1
WC-1
DRAIN SIZE (SEE PLANS)
DRAIN TYPE (SEE SCHEDULE)
CLEANOUT SIZE (SEE PLANS)
CLEANOUT TYPE (SEE SCHEDULE)
2 DFU DRAINAGE FIXTURE UNITS
(MAY NOT BE SHOWN)
400 SQFT
DRAIN SIZE (SEE PLANS)
DRAIN TYPE (SEE SCHEDULE)
AREA SERVED (MAY NOT BE SHOWN)
FIXTURE TYPE (SEE SCHEDULE)
2 CWFU
4 DFU
L-1
2 CWFU
2 HWFU
4 DFU
COLD WATER FIXTURE UNITS
HOT WATER FIXTURE UNITS
DRAINAGE FIXTURE UNITS
(SEE PLANS FOR
FIXTURE SYMBOL)
(FIXTURE UNITS MAY
NOT BE SHOWN)
4" WCO
CONDENSATE
DRAIN (D)D
2" FS-1
165° HOT WATER (HW)140 HWC
PLUMBING/PIPING SYMBOLS LEGEND
VALVE
GATE VALVE
BALL VALVE
GLOBE VALVE
PLUG VALVE
BUTTERFLY VALVE
SPECIALTY VALVE
OS & Y VALVE
STOP COCK
PRESSURE REDUCING
VALVE
PRESSURE REGULATING
VALVE
CHECK VALVE
SPRING CHECK VALVE
STRAINER
STRAINER W/
BLOWDOWN
BACKFLOW PREVENTER
BALANCING VALVE
AUTOMATIC BALANCING
VALVE
A
RELIEF VALVE
FUEL ANTI-SIPHON
VALVE
F
FUSIBLE OIL SAFETY
VALVE
MOTORIZED VALVE
NEEDLE VALVE
M M
SOLENOID VALVE
S S
AUTOMATIC CONTROL
VALVE
FLOW SWITCH
PRESSURE SWITCH
FS
PS
PIPE ELBOW DOWN
(OR AWAY)
PIPE ELBOW UP
(OR TOWARDS)
PIPE TEE DOWN
(OR AWAY)
PIPE TEE UP
(OR AWAY)
FLOW DIRECTION
PIPE SLOPE
& DIRECTION
REDUCER, CONCENTRIC
REDUCER, ECCENTRIC
UNION
FLANGES
BLIND FLANGE
END CAP
PT PLUG (TEST PORT)
FLEX CONNECTOR/
COUPLING
EXPANSION JOINT
EXPANSION GUIDE
PIPE ANCHOR
HOSE QUICK
DISCONNECT
HOSE THREAD DRAIN
BALL VALVE
HOSE BIBB
WALL HYDRANT
HOSE THREAD DRAIN
VALVE
FIRE DEPARTMENT
CONNECTION
WATER HAMMER
ARRESTOR
THERMOWELL
THERMOMETER
DIAL THERMOMETER
T
PRESSURE GAUGE
W/ COCK
P
PRESSURE GAUGE
W/ COCK & SIPHON
P
AIR VENT
A - AUTOMATIC
C - COIN
M - MANUAL
H - HIGH VOLUME
A
BASKET STRAINER
AIR FILTER W/
COALESCER & DRAIN
AIR FILTER W/
COALESCER, DRAIN,
REGULATOR & GAUGE
PUMP (SYMBOLIC -
ARROW INDICATES
FLOW DIRECTION)
WATER METERM
WATER HAMMER
ARRESTOR (PLAN)
V#
S=2%
PROJECT SUMMARY
HOMEWOOD SUITES IS A NEW-CONSTRUCTION 5-STORY HOTEL. THE GROUND FLOOR HAS
A LOBBY, POOL, WORKOUT ROOM, COMMON AREAS, AND SOME GUEST ROOMS, THE
FLOORS ABOVE ARE GUEST ROOMS WITH A FEW SUPPORT ROOMS.
THE MECHANICAL SYSTEMS USED IN THIS BUILDING INCLUDE AN ENERGY RECOVERY
DOAS UNIT PROVIDING OUTDOOR AIR AND EXHASUT AIR TO EACH SPACE IN THE BUILDING
OTHER THAN THE POOL AREA. HEATING AND COOLING FOR THESE SPACES WILL BE
PROVIDED BY DEDICATED IN-ROOM UNITS FOR THE GUEST ROOMS AND A VRF SYSTEM
FOR THE GROUND FLOOR. THE POOL AREA WILL BE SERVED BY AN AIR HANDLING UNIT
THAT VENTILATES, CONDITIONS, AND DEHUMIDIFIES THE POOL AIR.
THE PLUMBING SYSTEM COMPOSES OF A HOT WATER RECIRCULATION LOOP TO ALL
FLOORS OF THE BUILDING WITH NATURAL GAS WATER HEATERS ON THE GROUND FLOOR.
THE NEW EQUIPMENT WILL MEET ALL CURRENT APPLICABLE CODE AND USER
REQUIREMENTS.
THE ELECTRICAL DRAWINGS DETAIL THE ELECTRICAL-SPECIFIC REQUIREMENTS IN
ACCORDANCE WITH THE ABOVE.
www.coffman.com
221 N. Wall Street, Suite 500
Spokane, WA 99201
ph 509.328.2994
32 MERCHANT STREET, SUITE 208
HONOLULU, HI 96813
808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND
VERIFY ALL DIMENSIONS AT JOB BEFORE
PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER
MY SUPERVISION AND CONSTRUCTION OF THIS
PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 99216GENERAL MECHANICAL
NOTES AND LEGENDS
M-001
FSC PROJECT NO. 21012
PERMIT SET
MAY 30, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce Lane
Spokane, WA 99206
(509) 919-0901
MECHANICAL SHEET INDEX
SHEET NUMBER SHEET NAME
M-001 GENERAL MECHANICAL NOTES AND LEGENDS
M-100 GROUND FLOOR ZONE PLAN
M-101 GROUND FLOOR MECHANICAL PLAN
M-102 2ND FLOOR MECHANICAL PLAN
M-103 3RD FLOOR MECHANICAL PLAN
M-104 4TH FLOOR MECHANICAL PLAN
M-105 5TH FLOOR MECHANICAL PLAN
M-106 MECHANICAL ROOF PLAN
M-401 ENLARGED MECHANICAL PLANS
M-402 ENLARGED MECHANICAL PLANS
M-601 MECHANICAL CONTROL DIAGRAMS
M-701 MECHANICAL SCHEDULES
M-702 MECHANICAL SCHEDULES
M-703 MECHANICAL SCHEDULES
P-100 UNDERFLOOR PLUMBING PLAN
P-101 GROUND FLOOR PLUMBING PLAN
P-102 2ND FLOOR PLUMBING PLAN
P-103 3RD FLOOR PLUMBING PLAN
P-104 4TH FLOOR PLUMBING PLAN
P-105 5TH FLOOR PLUMBING PLAN
P-106 PLUMBING ROOF PLAN
P-111 GROUND FLOOR REFRIGERANT AND CONDENSATE PIPING PLAN
P-112 2ND FLOOR REFRIGERANT AND CONDENSATE PIPING PLAN
P-113 3RD FLOOR REFRIGERANT AND CONDENSATE PIPING PLAN
P-114 4TH FLOOR REFRIGERANT AND CONDENSATE PIPING PLAN
P-115 5TH FLOOR REFRIGERANT AND CONDENSATE PIPING PLAN
P-401 ENLARGED PLUMBING PLANS
P-402 ENLARGED PLUMBING PLANS
P-403 ENLARGED WATER HEATER ROOM
P-501 PLUMBING DETAILS
P-502 PLUMBING DETAILS
P-601 WASTE AND VENT RISER DIAGRAM
P-602 WASTE AND VENT RISER DIAGRAM
P-603 DOMESTIC WATER RISER DIAGRAM
P-604 DOMESTIC WATER RISER DIAGRAM
P-605 CONDENSATE DRAIN RISER DIAGRAM
P-701 PLUMBING SCHEDULES
P-702 PLUMBING SCHEDULES
Revision Schedule
Number Description Date
5/30/2024
D D D D
WWWW
D D D D
WWWW
T
T
T
T
T
T
T
T
T
T
A
A
B
B
C
C D
C.1 E
E
F
F
G
G
H
H
J
J
K
K
L.1
L.1
M
M
N
N
P
P
Q
Q
99
8.1
88
77
6.1
66
55
44
3.13.1
33
2.12.1
1.11.1
2 2
POOL & SPLASH PAD
101
PUBLIC CORRIDOR
100
ELECTRICAL
104
POOL RESTROOM
102
POOL MEP
103
STAIR 1
106
WATER HEATER & FIRE
108
BOH LAUNDRY
105
BOH DRYERS
105A
LINEN DISCHARGE &
SORTING
107
ELEV 1
111
ELEVATOR LOBBY
117
ELEV 2
113
EMPLOYEE ROOM
110
LAUNDRY LOUNGE
112
EMP RR
110B
EMP RR ADA
110A LINEN STORAGE
109
HOUSEKEEPING OFFICE
109A
FITNESS
114
MEN'S RESTROOM
116
WOMEN'S RESTROOM
115
GUEST STORAGE
118
MEETING STORAGE
119
MEETING ROOM
120
LOBBY
121
FOOD PREP
123
OPEN OFFICE
124 ELECTRICAL
128
VESTIBULE
122
COURTYARD STORAGE
141
EFFICIENCY
129
EFFICIENCY
131
EFFICIENCY
133
DOUBLE QUEEN
135 KING STUDIO
137
KING STUDIO ADA-M-T
138
DOUBLE QUEEN
136
EFFICIENCY
134
STAIR 2
132
KING STUDIO
130
GUEST CORRIDOR
139
ZONE 1
ZONE 2
ZONE 3
ZONE 4 ZONE 5
ZONE 6 ZONE 7
ZONE 8
1
ZONE 9
GM OFFICE
125
SALES OFFICE
126 OWNER'S OFFICE
127
FCU-216
FCU-217
FCU-215
FCU-311
FCU-212
BCU-02
FCU-211
EH-11
EH-12
FCU-213
AHU-01
AHU-01
UH-01
GENERAL NOTES
A. ZONE PLAN PROVIDED FOR GROUND FLOOR ONLY. ALL GUEST
ROOMS ARE INDIVIDUALLY ZONED BY PTAC. SEE ENLARGED
GUEST ROOM PLANS FOR FURTHER DETAILS.
B. THERMOSTAT LOCATION SHALL BE COORDINATED WITH OWNER
AND ARCHITECT PRIOR TO FINAL PLACEMENT.
C. NON-ADJUSTABLE DIGITAL TEMPERATURE SENSORS SHALL BE
PROVIDED IN PUBLIC AREAS. UNLESS SPECIFICALLY NOTED ON
PLANS, PUBLIC ZONES SHALL NOT BE ADJUSTABLE BY GUESTS.
D. DUCTS SHALL BE CONSTRUCTED OF MINIMUM 26-GUAGE STEEL.
DUCT PENETRATIONS THROUGH 1-HR OR LESS RATED FIRE
PARTITIONS IN GUEST CORRIDOR DO NOT REQUIRE FIRE
DAMPERS PER IBE 717.5.4 EXCEPTION 4.
UH-02
www.coffman.com
221 N. Wall Street, Suite 500
Spokane, WA 99201
ph 509.328.2994
32 MERCHANT STREET, SUITE 208
HONOLULU, HI 96813
808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND
VERIFY ALL DIMENSIONS AT JOB BEFORE
PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER
MY SUPERVISION AND CONSTRUCTION OF THIS
PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 99216GROUND FLOOR ZONE
PLAN
M-100
FSC PROJECT NO. 21012
PERMIT SET
MAY 30, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce Lane
Spokane, WA 99206
(509) 919-0901
3/32" = 1'-0"
GROUND FLOOR ZONE PLAN
0'6'12'24'
SCALE: 3/32" = 1'-0"
KEY NOTES
1 MEETING ROOM THERMOSTAT MUST BE ADJUSTABLE BY
GUESTS.
3/32" = 1'-0"
STORAGE SHED ZONE PLAN
Revision Schedule
Number Description Date
5/30/2024
MMMMMMMMMMMMMMMMMAA
A
A
A
AA
A
A
AAAAAAAAAAAAAAAAAAAAAAAAAAAAAM
AMM
A
A
B
B
C
C D
C.1
C.1
E
E
F
F
G
G
H
H
J
J
K
K
L.1
L.1
M
M
N
N
P
P
Q
Q
99
8.1
88
77
6.1
66
55
44
3.13.1
33
2.12.1
1.11.1
2 2
MEN'S RESTROOM
116
WOMEN'S RESTROOM
115
MEETING STORAGE
119
MEETING ROOM
120
GUEST STORAGE
118
FITNESS
114
VESTIBULE
122
FOOD PREP
123
COURTYARD STORAGE
141
ELEV 2
113
ELEV 1
111
EFFICIENCY
129
EFFICIENCY
131
EFFICIENCY
133
KING STUDIO
130 STAIR 2
132
EFFICIENCY
134
GUEST CORRIDOR
139
ELEVATOR LOBBY
117
LOBBY
121
LAUNDRY LOUNGE
112
EMPLOYEE ROOM
110
WATER HEATER & FIRE
108
EMP RR ADA
110A
POOL & SPLASH PAD
101
POOL RESTROOM
102
ELECTRICAL
104
STAIR 1
106
PUBLIC CORRIDOR
100
BOH LAUNDRY
105
LINEN STORAGE
109
LINEN CHUTE
140
LINEN DISCHARGE &
SORTING
107
POOL MEP
103
DOUBLE QUEEN
135
KING STUDIO
137
DOUBLE QUEEN
136
KING STUDIO ADA-M-T
138
?
??
?
?
?
OPEN OFFICE
124
ELECTRICAL
128
M-401
1 M-401
4
M-402
1
M-402
2
AHU-01
WH-2WH-1 WH-3
20x18
28x1218ø
18ø 12ø
12øFCU-213
FCU-212
FCU-216
DH-01
FCU-211
FCU-215
EH-11
6ø
10ø
10ø
8ø
WH-4
2R
1651S
160
4S
2103E
150
1R
50
1S
160
FCU-217
6S
435
2S
25
6S
435
5S
435
2S
25
4E
200
5R
475
1E
50
1E
502E
100
2S
425
2S
50
5R
475
2S
60
8S
525
2S
25 2S
70
2R
165
4E
200
2R
165
1S
100
4R
435
2S
190
6S
325 6S
325
4S
190
6S
325
6S
325
4R
435
4R
4305E
285
5E
280
8S
635
8S
635
2S
255R
490
2S
25
6S
320
2S
160
2S
160 2S
25
2S
25
4R
4354S
195
6S
3101S
50
4R
4304S
190
4R
435
6S
310
6S
310
2S
150
6S
400
6S
4003E
150
1S
150
4S
300
6R
700
1S
100
4R
300
3E
150
3E
150
7R
1305
1S
150
1S
100
FCU-311
3E
115
2S
125
2S
100
1S
90
1S
50
1S
65
4ø
4ø6ø8ø10ø14ø 4ø6ø3E
100
16ø 16ø 12ø12ø
4ø12ø8ø
8ø
10ø 2S
1708ø10ø
4ø
12ø6ø6ø
4ø4ø14ø
10ø10ø12ø8ø12ø16ø12ø8ø 10ø10ø14ø
8ø12ø
20x1810ø 10ø14ø18x16
12ø
14ø 12ø10ø
8ø8ø8ø
8ø
8ø
8ø10ø
4ø16ø
12ø12ø16ø
12ø
4ø
4ø10ø12ø16ø12ø
10ø6ø
8ø10ø
6ø
16x1412x10
18x166ø 10ø12ø12ø12ø
14ø 4ø12x1010ø6ø6ø8ø4ø6ø 12ø9ø 4ø DRYER
CLEANOUT
6ø
8ø
8ø
8ø12ø10ø
8ø
8ø6ø8ø 6ø 16ø16ø8ø
8ø
8ø
1
2
28x12
1E
50
7E
305
10ø
28x12
14x14
UP TO
EF-02
18x18 UP
TO EF-0110S
232
10S
232
10S
232
10S
232
10S
155
10S
206
10S
206
10S
206
EH-12
10S
155
10S
155
10S
155
10S
155
10S
155
10S
155
10S
155
10S
155
10S
155
8R
15508R
1550
UH-01
8ø
8ø16ø16ø
12ø
2R
200
10ø
10ø
14ø10ø
10ø
6ø
6R
635
6R
635
10ø
16ø
8ø
EF-04 EF-05
18x16
FSD-11 FSD-12
4" FLUE
VENT UP
THROUGH
ROOF
3
4
5LV-04
ALAL AL
AL ALAL
AL
AL
LV-02LV-01
FD-11
FD-12
14ø
FCU-214
EF-03
14øSSLV-05
MAU-01
14x14
6
GENERAL NOTES
A. MOTORIZED DAMPERS SHALL BE PROVIDED TO EACH GUEST
ROOM PER WSEC C403.7.4.2 TO SERVE AS ISOLATION DEVICES
CAPABLE OF AUTOMATICALLY SHUTTING OFF THE SUPPLY OF
OUTDOOR AIR TO AND EXHAUST AIR FROM EACH GUEST ROOM.
CONSTANT VOLUME DAMPER SHALL BE INSTALLED IN DUCT
BRANCHES SERVING GUEST ROOMS, SET TO AUTOMATICALLY
CONTROL AIRFLOW TO THE VALUES SHOWN ON PLANS; BASIS-OF-
DESIGN IS ALDES CAR3.
B. GUEST ROOM HEATING AND COOLING PTAC UNITS SHALL BE
PROVIDED TO MEET WSEC C403.7.4.1 WITH CONTROLS
CONFIGURED TO AUTOMATICALLY RAISE THE SET POINTS.
C. REMOTE, WALL-MOUNTED, HARD-WIRED, ELECTRONIC DIGITAL
THERMOSTAT SPECIFICALLY DESIGNED FOR GUEST SUITE
APPLICATIONS MUST BE PROVIDED. STUDIO SUITES AND MULTI-
ROOM SUITES, SERVED BY A SINGLE HVAC UNIT, MUST HAVE THE
THERMOSTAT LOCATED IN THE MAIN SLEEPING AREA. GUEST
ROOMS SERVED BY MULTIPLE HVAC UNITS MUST HAVE A
THERMOSTAT FOR EACH HVAC UNIT LOCATED IN THE SPACE
SERVED BY THAT UNIT. BATTERY POWERED THERMOSTATS ARE
NOT ACCEPTABLE.
D. DUCTWORK DIRECTLY SERVING THE POOL AND POOL MEP ROOMS
SHALL BE CONSTRUCTED OF ALUMINUM.
E. DUCTS SHALL BE CONSTRUCTED OF MINIMUM 26-GUAGE STEEL.
DUCT PENETRATIONS THROUGH 1-HR (OR LESS) RATED FIRE
PARTITIONS IN GUEST CORRIDOR DO NOT REQUIRE FIRE
DAMPERS PER IBC 717.5.4 EXCEPTION 4.
UH-02
www.coffman.com
221 N. Wall Street, Suite 500
Spokane, WA 99201
ph 509.328.2994
32 MERCHANT STREET, SUITE 208
HONOLULU, HI 96813
808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND
VERIFY ALL DIMENSIONS AT JOB BEFORE
PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER
MY SUPERVISION AND CONSTRUCTION OF THIS
PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 99216GROUND FLOOR
MECHANICAL PLAN
M-101
FSC PROJECT NO. 21012
PERMIT SET
MAY 30, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce Lane
Spokane, WA 99206
(509) 919-0901
3/32" = 1'-0"
GROUND FLOOR MECHANICAL PLAN
0'6'12'24'
SCALE: 3/32" = 1'-0"
KEY NOTES
1 INSTALL DRYER VENTING ACCORDING TO MANUFACTURER'S
INSTRUCTIONS TO INCLUDE CLEARANCE MINIMUMS FROM
GROUND LEVEL AND OTHER OPENINGS. DUCTWORK SHALL BE
INSTALLED HIGH ENOUGH TO NOT PROHIBIT MAINTENANCE
ACCESS IN THIS AREA.
2 INSTALL WATER HEATER CONCENTRIC VENTING ACCORDING
TO MANUFACTURER'S INSTRUCTIONS TO INCLUDE CLEARANCE
MINIMUMS/MAXIMUMS FROM GROUND LEVEL AND OTHER
OPENINGS. BASIS-OF-DESIGN IS 4 CONCENTRIC PENETRATIONS
IN A SQUARE PATTERN WITH END CAPS 0-2 INCHES APART.
PENETRATIONS SHALL NOT BE LOCATED OVER DOORWAY OR
WALKWAY.
3 INSTALL DRYER VENTING ACCORDING TO MANUFACTURES
INTRUCTIONS TO INCLUDE CLEARANCE MINIMUMS FROM
GROUND LEVEL AND OTHER OPENINGS. AT CONTRACTORS
OPTION, COMBINED VENT SYSTEM MAY BE INSTALLED OR
INDIVIDUAL VENTS FOR EACH DRYER; CLEANOUTS AND
BACKDRAFT PROTECTION SHALL BE INSTALLED ACCORDING TO
METHOD USED. WALL PENETRATION SHALL BE SEALED
ACCORDING TO IMC SECTION 504.
4 GREASE DUCT SERVING KITCHEN HOOD SHALL BE 20-GA, 430
STAINLESS STEEL, LISTED TO UL-1978 (CAPTIVEAIRE SYSTEMS
"DW") WITH SEALED CONNECTIONS AND FIRE BARRIER (3M FIRE
BARRIER 2000 PLUS) INSTALLED ACCORDING TO
MANUFACTURER'S INSTALLATIONS TO INCLUDE RATED ACCESS
DOORS AND SLOPING.
5 INTER-LOCK CONTROL DAMPER AT LV-04 WITH ALL THREE
CLOTHES DRYERS. IF ANY OF THE CLOTHES DRYERS IS
OPERATING, LV-04 OPENS. IF ALL THREE DRYERS ARE OFF,
LV-04 SHALL CLOSE.
6 KITCHEN HOOD MAKEUP AIR UNIT REQUIRES DOMESTIC COLD
CONNECTION AND SANITARY WASTE CONNECTION. UNIT
INSTALLED SUPPORTED FROM ABOVE. INSTALL VENT AND
INTAKE PIPES THROUGH EXTERIOR WALL TO INTERNAL
FURNACE COMPONENT ACCORDING TO MANUFACTURER'S
INSTRUCTIONS.
3/32" = 1'-0"
STORAGE SHED MECHANICAL PLAN
Revision Schedule
Number Description Date
5/30/2024
M
M M
M
M
M
M
MM
M
M
M M
M M
M
M
M
MMMMMMMMMM MMMMMM MMMMMMMMMMMMMMMMMMMMMMMMMMMMMA
A
AA
A
A
A
A
A
AA
A
A
A
A
A
A
A
A
A
A
AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAM
M
A
A
B
B
C
C D
C.1 E
E
F
F
G
G
H
H
J
J
K
K
L.1
L.1
M
M
N
N
P
P
Q
Q
99
8.1
88
77
6.1
66
5
44
3.13.1
33
2.12.1
1.1
2 2
ELEV 2
113
ELEV 1
111
LINEN CHUTE
140
KING STUDIO
237
KING STUDIO ADA-M-T
238
DOUBLE QUEEN
236
DOUBLE QUEEN
235
EFFICIENCY
233
KING 1-BEDROOM
202
KING 1-BEDROOM ENLARGED
201
DOUBLE QUEEN
210
KING STUDIO
204
DOUBLE QUEEN ENLARGED
212
KING STUDIO
214
ENGINEERING OFFICE &
STORAGE
207
ELEVATOR LOBBY
217
LINENES & HOUSEKEEPING
209
EFFICIENCY ENLARGED
203
CONNECTING CORRIDOR
200
?
?
EFFICIENCY
229
EFFICIENCY
227
EFFICIENCY
208
EFFICIENCY
205
KING STUDIO
220
KING STUDIO
218
KING STUDIO
216 KING STUDIO
226
KING STUDIO
219
KING STUDIO
221
KING STUDIO
223
KING STUDIO
225
DOUBLE QUEEN
224
DOUBLE QUEEN
222
GUEST CORRIDOR
215
EFFICIENCY
228
EFFICIENCY
231
EFFICIENCY
234
KING STUDIO
230
STAIR 2
232
STAIR 1
206
PBX/MDF
207A
M-402
3
M-402
4
M-401
3
M-401
5
CU-01
FCU-323
FCU-322
FCU-421
FCU-324
1S
25
1E
25
10ø
10ø
1E
55
FCU-321
2S
80
16x8
12x810ø 4ø
4ø
6ø8ø
10ø12ø
EF-02
EF-01
EH-22
T
T
T
10ø
8ø
6ø
4ø
4ø4ø4ø4ø
4R
300
10ø
8ø
1S
50
6S
300FCU-326
T
FCU-325
T
2S
50
26x104ø
4ø
6ø
4ø
16x8
16x8
12x8
FSD-21
FSD-22
4" DUCT
HEATER
VENT UP
THROUGH
ROOF
EH-21
7S
600
7R
600
GENERAL NOTES
A. MOTORIZED DAMPERS SHALL BE PROVIDED TO EACH GUEST
ROOM PER WSEC C403.7.4.2 TO SERVE AS ISOLATION DEVICES
CAPABLE OF AUTOMATICALLY SHUTTING OFF THE SUPPLY OF
OUTDOOR AIR TO AND EXHAUST AIR FROM EACH GUEST ROOM.
CONSTANT VOLUME DAMPER SHALL BE INSTALLED IN DUCT
BRANCHES SERVING GUEST ROOMS, SET TO AUTOMATICALLY
CONTROL AIRFLOW TO THE VALUES SHOWN ON PLANS; BASIS-OF-
DESIGN IS ALDES CAR3.
B. GUEST ROOM HEATING AND COOLING PTAC UNITS SHALL BE
PROVIDED TO MEET WSEC C403.7.4.1 WITH CONTROLS
CONFIGURED TO AUTOMATICALLY RAISE THE SET POINTS.
C. REMOTE, WALL-MOUNTED, HARD-WIRED, ELECTRONIC DIGITAL
THERMOSTAT SPECIFICALLY DESIGNED FOR GUEST SUITE
APPLICATIONS MUST BE PROVIDED. STUDIO SUITES AND MULTI-
ROOM SUITES, SERVED BY A SINGLE HVAC UNIT, MUST HAVE THE
THERMOSTAT LOCATED IN THE MAIN SLEEPING AREA. GUEST
ROOMS SERVED BY MULTIPLE HVAC UNITS MUST HAVE A
THERMOSTAT FOR EACH HVAC UNIT LOCATED IN THE SPACE
SERVED BY THAT UNIT. BATTERY POWERED THERMOSTATS ARE
NOT ACCEPTABLE.
D. DUCTWORK DIRECTLY SERVING THE POOL AND POOL MEP ROOMS
SHALL BE CONSTRUCTED OF ALUMINUM.
E. DUCTS SHALL BE CONSTRUCTED OF MINIMUM 26-GUAGE STEEL.
DUCT PENETRATIONS THROUGH 1-HR (OR LESS) RATED FIRE
PARTITIONS IN GUEST CORRIDOR DO NOT REQUIRE FIRE
DAMPERS PER IBC 717.5.4 EXCEPTION 4.
www.coffman.com
221 N. Wall Street, Suite 500
Spokane, WA 99201
ph 509.328.2994
32 MERCHANT STREET, SUITE 208
HONOLULU, HI 96813
808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND
VERIFY ALL DIMENSIONS AT JOB BEFORE
PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER
MY SUPERVISION AND CONSTRUCTION OF THIS
PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 992162ND FLOOR
MECHANICAL PLAN
M-102
FSC PROJECT NO. 21012
PERMIT SET
MAY 30, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce Lane
Spokane, WA 99206
(509) 919-0901
3/32" = 1'-0"
2ND FLOOR MECHANICAL PLAN
0'6'12'24'
SCALE: 3/32" = 1'-0"
Revision Schedule
Number Description Date
5/30/2024
MMM M
M
M
M
M
MM
M
M
M M
M M
M
M
M
MMMMMMMMMM MMMMMM MMMMMMMMMMMMMMMMMMMMMMMMMMMMMA
AA
A
A
A
A
A
AA
A
A
A
A
A
A
A
A
A
A
AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAM
A
A
A
B
B
C
C D
C.1 E
E
F
F
G
G
H
H
J
J
K
K
L.1
L.1
M
M
N
N
P
P
Q
Q
99
8.1
88
77
6.1
66
55
44
3.13.1
33
2.12.1
1.11.1
2 2
ELEV 2
113
ELEV 1
111
LINEN CHUTE
140
KING STUDIO
337
KING STUDIO ADA-M-RI
338
DOUBLE QUEEN
336
DOUBLE QUEEN
335
EFFICIENCY
333
KING 1-BEDROOM
302
KING 1-BEDROOM ADA-M-T
301
DOUBLE QUEEN
310
KING STUDIO
304
DOUBLE QUEEN ENLARGED
312
KING STUDIO
314
EFFICIENCY
307
ELEVATOR LOBBY
317
LINENES & HOUSEKEEPING
309
EFFICIENCY ENLARGED
303
CONNECTING CORRIDOR
300
?
?
EFFICIENCY
329
EFFICIENCY
327
EFFICIENCY
308
EFFICIENCY
305
KING STUDIO
320
KING STUDIO
318
KING STUDIO
316
KING STUDIO
326
KING STUDIO
319
KING STUDIO
321
KING STUDIO
323
KING STUDIO
325
DOUBLE QUEEN
324
DOUBLE QUEEN
322
GUEST CORRIDOR
315
EFFICIENCY
328
EFFICIENCY
331
EFFICIENCY
334
KING STUDIO
330 STAIR 2
332
STAIR 1
306
M-402
5
M-401
2
1S
25
1E
25
1E
55
2S
80
16x8
16x810ø 4ø
4ø
6ø8ø
10ø12ø
10ø
8ø
6ø
4ø
4ø4ø4ø
4R
300
10ø
8ø
1S
50
6S
300
2S
50
26x104ø
4ø
6ø
4ø
16x8
16x8
16x8
FSD-31
FSD-32
FCU-331
FCU-334
FCU-332 FCU-333
FCU-335
EH-32
4ø
EH-31
GENERAL NOTES
A. MOTORIZED DAMPERS SHALL BE PROVIDED TO EACH GUEST
ROOM PER WSEC C403.7.4.2 TO SERVE AS ISOLATION DEVICES
CAPABLE OF AUTOMATICALLY SHUTTING OFF THE SUPPLY OF
OUTDOOR AIR TO AND EXHAUST AIR FROM EACH GUEST ROOM.
CONSTANT VOLUME DAMPER SHALL BE INSTALLED IN DUCT
BRANCHES SERVING GUEST ROOMS, SET TO AUTOMATICALLY
CONTROL AIRFLOW TO THE VALUES SHOWN ON PLANS; BASIS-OF-
DESIGN IS ALDES CAR3.
B. GUEST ROOM HEATING AND COOLING PTAC UNITS SHALL BE
PROVIDED TO MEET WSEC C403.7.4.1 WITH CONTROLS
CONFIGURED TO AUTOMATICALLY RAISE THE SET POINTS.
C. REMOTE, WALL-MOUNTED, HARD-WIRED, ELECTRONIC DIGITAL
THERMOSTAT SPECIFICALLY DESIGNED FOR GUEST SUITE
APPLICATIONS MUST BE PROVIDED. STUDIO SUITES AND MULTI-
ROOM SUITES, SERVED BY A SINGLE HVAC UNIT, MUST HAVE THE
THERMOSTAT LOCATED IN THE MAIN SLEEPING AREA. GUEST
ROOMS SERVED BY MULTIPLE HVAC UNITS MUST HAVE A
THERMOSTAT FOR EACH HVAC UNIT LOCATED IN THE SPACE
SERVED BY THAT UNIT. BATTERY POWERED THERMOSTATS ARE
NOT ACCEPTABLE.
D. DUCTWORK DIRECTLY SERVING THE POOL AND POOL MEP ROOMS
SHALL BE CONSTRUCTED OF ALUMINUM.
E. DUCTS SHALL BE CONSTRUCTED OF MINIMUM 26-GUAGE STEEL.
DUCT PENETRATIONS THROUGH 1-HR (OR LESS) RATED FIRE
PARTITIONS IN GUEST CORRIDOR DO NOT REQUIRE FIRE
DAMPERS PER IBC 717.5.4 EXCEPTION 4.
www.coffman.com
221 N. Wall Street, Suite 500
Spokane, WA 99201
ph 509.328.2994
32 MERCHANT STREET, SUITE 208
HONOLULU, HI 96813
808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND
VERIFY ALL DIMENSIONS AT JOB BEFORE
PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER
MY SUPERVISION AND CONSTRUCTION OF THIS
PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 992163RD FLOOR
MECHANICAL PLAN
M-103
FSC PROJECT NO. 21012
PERMIT SET
MAY 30, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce Lane
Spokane, WA 99206
(509) 919-0901
3/32" = 1'-0"
3RD FLOOR MECHANICAL PLAN
0'6'12'24'
SCALE: 3/32" = 1'-0"
Revision Schedule
Number Description Date
5/30/2024
MMM M
M M
M
M
MM
M
M
M M
M M
M
M
M
MMMMMMMMMM MMMMMM MMMMMMMMMMMMMMMMMMMMMMMMMMMMMA
AA
A
A
AA
A
AA
A
A
A
A
A
A
A
A
A
A
AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAM
A
A
A
B
B
C
C D
C.1 E
E
F
F
G
G
H
H
J
J
K
K
L.1
L.1
M
M
N
N
P
P
Q
Q
99
8.1
88
77
6.1
66
55
44
3.13.1
33
2.12.1
1.11.1
2 2
ELEV 2
113
ELEV 1
111
KING STUDIO
437
KING STUDIO ENLARGED
438
DOUBLE QUEEN
436
DOUBLE QUEEN
435
EFFICIENCY
433
KING 1-BEDROOM
402
KING 1-BEDROOM ENLARGED
401
DOUBLE QUEEN
410
KING STUDIO
404
DOUBLE QUEEN ENLARGED
412
KING STUDIO
414
EFFICIENCY
407
PANELS
409A
ELEVATOR LOBBY
417
LINENES & HOUSEKEEPING
409
EFFICIENCY ADA-M-RI
403
CONNECTING CORRIDOR
400
?
?
EFFICIENCY
429
EFFICIENCY
427
EFFICIENCY
408
EFFICIENCY
405
KING STUDIO
420
KING STUDIO
418
KING STUDIO
416 KING STUDIO
426
KING STUDIO
419
KING STUDIO
421
KING STUDIO
423
KING STUDIO
425
DOUBLE QUEEN
424
DOUBLE QUEEN
422
GUEST CORRIDOR
415
EFFICIENCY
428
EFFICIENCY
431
EFFICIENCY
434
KING STUDIO
430 STAIR 2
432
STAIR 1
406
IDF
409B
M-401
6
1S
25
1E
25
1E
55
2S
80
16x8
12x810ø 4ø
4ø
6ø8ø
10ø12ø
10ø
8ø
6ø
4ø
4ø4ø4ø
4R
300
10ø
8ø
1S
50
6S
300
2S
50
26x104ø
4ø
6ø
4ø
16x8
16x8
12x8
FSD-41
FSD-42
FCU-341
EH-41
FCU-342 FCU-343
FCU-344 FCU-345
EH-42
4ø
GENERAL NOTES
A. MOTORIZED DAMPERS SHALL BE PROVIDED TO EACH GUEST
ROOM PER WSEC C403.7.4.2 TO SERVE AS ISOLATION DEVICES
CAPABLE OF AUTOMATICALLY SHUTTING OFF THE SUPPLY OF
OUTDOOR AIR TO AND EXHAUST AIR FROM EACH GUEST ROOM.
CONSTANT VOLUME DAMPER SHALL BE INSTALLED IN DUCT
BRANCHES SERVING GUEST ROOMS, SET TO AUTOMATICALLY
CONTROL AIRFLOW TO THE VALUES SHOWN ON PLANS; BASIS-OF-
DESIGN IS ALDES CAR3.
B. GUEST ROOM HEATING AND COOLING PTAC UNITS SHALL BE
PROVIDED TO MEET WSEC C403.7.4.1 WITH CONTROLS
CONFIGURED TO AUTOMATICALLY RAISE THE SET POINTS.
C. REMOTE, WALL-MOUNTED, HARD-WIRED, ELECTRONIC DIGITAL
THERMOSTAT SPECIFICALLY DESIGNED FOR GUEST SUITE
APPLICATIONS MUST BE PROVIDED. STUDIO SUITES AND MULTI-
ROOM SUITES, SERVED BY A SINGLE HVAC UNIT, MUST HAVE THE
THERMOSTAT LOCATED IN THE MAIN SLEEPING AREA. GUEST
ROOMS SERVED BY MULTIPLE HVAC UNITS MUST HAVE A
THERMOSTAT FOR EACH HVAC UNIT LOCATED IN THE SPACE
SERVED BY THAT UNIT. BATTERY POWERED THERMOSTATS ARE
NOT ACCEPTABLE.
D. DUCTWORK DIRECTLY SERVING THE POOL AND POOL MEP ROOMS
SHALL BE CONSTRUCTED OF ALUMINUM.
E. DUCTS SHALL BE CONSTRUCTED OF MINIMUM 26-GUAGE STEEL.
DUCT PENETRATIONS THROUGH 1-HR (OR LESS) RATED FIRE
PARTITIONS IN GUEST CORRIDOR DO NOT REQUIRE FIRE
DAMPERS PER IBC 717.5.4 EXCEPTION 4.
www.coffman.com
221 N. Wall Street, Suite 500
Spokane, WA 99201
ph 509.328.2994
32 MERCHANT STREET, SUITE 208
HONOLULU, HI 96813
808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND
VERIFY ALL DIMENSIONS AT JOB BEFORE
PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER
MY SUPERVISION AND CONSTRUCTION OF THIS
PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 992164TH FLOOR
MECHANICAL PLAN
M-104
FSC PROJECT NO. 21012
PERMIT SET
MAY 30, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce Lane
Spokane, WA 99206
(509) 919-0901
3/32" = 1'-0"
4TH FLOOR MECHANICAL PLAN
0'6'12'24'
SCALE: 3/32" = 1'-0"
Revision Schedule
Number Description Date
5/30/2024
MMM M
M M
M
M
MM
M
M
M M
M M
M
M
M
MMMMMMMMMM MMMMMM MMMMMMMMMMMMMMMMMMMMMMMMMMMMMAA
A
A
AA
A
AA
A
A
A
A
A
A
A
A
A
A
AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAM
A
A
A
B
B
C
C D
C.1 E
E
F
F
G
G
H
H
J
J
K
K
L.1
L.1
M
M
N
N
P
P
Q
Q
99
8.1
88
77
6.1
66
55
44
3.13.1
33
2.1
1.11.1
2
ELEV 2
113
ELEV 1
111
KING STUDIO
537
KING STUDIO ENLARGED
538
DOUBLE QUEEN
536
DOUBLE QUEEN
535
EFFICIENCY
533
KING 1-BEDROOM
502
KING 1-BEDROOM ENLARGED
501
DOUBLE QUEEN
510
KING STUDIO
504
DOUBLE QUEEN ADA-M-T
512
KING STUDIO
514
EFFICIENCY
507
ELEVATOR LOBBY
517
LINENES & HOUSEKEEPING
509
EFFICIENCY ADA-M-T
503
CONNECTING CORRIDOR
500
?
?
EFFICIENCY
529
EFFICIENCY
527
EFFICIENCY
508
EFFICIENCY
505
KING STUDIO
520
KING STUDIO
518
KING STUDIO
516
KING STUDIO
526
KING STUDIO
519
KING STUDIO
521
KING STUDIO
523
KING STUDIO
525
DOUBLE QUEEN
524
DOUBLE QUEEN
522
GUEST CORRIDOR
515
EFFICIENCY
528
EFFICIENCY
531
EFFICIENCY
534
KING STUDIO
530
STAIR 1
506
1S
25
1E
25
1E
55
2S
80
16x8
12x810ø 4ø
4ø
6ø8ø
10ø12ø
10ø
8ø
6ø
4ø
4ø4R
300
10ø
8ø
1S
50
6S
300
2S
50
26x104ø
4ø
6ø
4ø
16x8
16x8
12x8
FSD-51
FSD-52
FCU-351
FCU-352 FCU-353
FCU-354 FCU-355
4ø4ø4ø
STAIR 2
532
EH-51
EH-52
GENERAL NOTES
A. MOTORIZED DAMPERS SHALL BE PROVIDED TO EACH GUEST
ROOM PER WSEC C403.7.4.2 TO SERVE AS ISOLATION DEVICES
CAPABLE OF AUTOMATICALLY SHUTTING OFF THE SUPPLY OF
OUTDOOR AIR TO AND EXHAUST AIR FROM EACH GUEST ROOM.
CONSTANT VOLUME DAMPER SHALL BE INSTALLED IN DUCT
BRANCHES SERVING GUEST ROOMS, SET TO AUTOMATICALLY
CONTROL AIRFLOW TO THE VALUES SHOWN ON PLANS; BASIS-OF-
DESIGN IS ALDES CAR3.
B. GUEST ROOM HEATING AND COOLING PTAC UNITS SHALL BE
PROVIDED TO MEET WSEC C403.7.4.1 WITH CONTROLS
CONFIGURED TO AUTOMATICALLY RAISE THE SET POINTS.
C. REMOTE, WALL-MOUNTED, HARD-WIRED, ELECTRONIC DIGITAL
THERMOSTAT SPECIFICALLY DESIGNED FOR GUEST SUITE
APPLICATIONS MUST BE PROVIDED. STUDIO SUITES AND MULTI-
ROOM SUITES, SERVED BY A SINGLE HVAC UNIT, MUST HAVE THE
THERMOSTAT LOCATED IN THE MAIN SLEEPING AREA. GUEST
ROOMS SERVED BY MULTIPLE HVAC UNITS MUST HAVE A
THERMOSTAT FOR EACH HVAC UNIT LOCATED IN THE SPACE
SERVED BY THAT UNIT. BATTERY POWERED THERMOSTATS ARE
NOT ACCEPTABLE.
D. DUCTWORK DIRECTLY SERVING THE POOL AND POOL MEP ROOMS
SHALL BE CONSTRUCTED OF ALUMINUM.
E. DUCTS SHALL BE CONSTRUCTED OF MINIMUM 26-GUAGE STEEL.
DUCT PENETRATIONS THROUGH 1-HR (OR LESS) RATED FIRE
PARTITIONS IN GUEST CORRIDOR DO NOT REQUIRE FIRE
DAMPERS PER IBC 717.5.4 EXCEPTION 4.
www.coffman.com
221 N. Wall Street, Suite 500
Spokane, WA 99201
ph 509.328.2994
32 MERCHANT STREET, SUITE 208
HONOLULU, HI 96813
808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND
VERIFY ALL DIMENSIONS AT JOB BEFORE
PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER
MY SUPERVISION AND CONSTRUCTION OF THIS
PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 992165TH FLOOR
MECHANICAL PLAN
M-105
FSC PROJECT NO. 21012
PERMIT SET
MAY 30, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce Lane
Spokane, WA 99206
(509) 919-0901
3/32" = 1'-0"
5TH FLOOR MECHANICAL PLAN
0'6'12'24'
SCALE: 3/32" = 1'-0"
Revision Schedule
Number Description Date
5/30/2024
A
A
B
B
C
C D
C.1
C.1
E
E
F
F
G
G
H
H
J
J
K
K
L.1
L.1
M
M
N
N
P
P
Q
Q
99
8.1
88
77
6.1
66
55
44
3.13.1
33
2.12.1
1.11.1
2 2
ERV-01
30x30
30x30
CU-02
CONDENSING UNIT FOR VRF
SYSTEM SERVING THE
GROUND FLOOR
RL/RS DN
LINEN CHUTE
VENT PROVIDED
BY VENDOR
CONDENSING UNIT FOR THE
ELEVATOR MACHINE SPACE CU-05
CU-03
CU-04
11
1
2
3
1
GENERAL NOTES
A. LOCATE PLUMBING VENTS AND EXHAUST FANS/STACKS 25'-0" MIN.
FROM HVAC AIR INTAKES, AS SHOWN WITH DASHED CIRCLES ON
PLAN.
B. LOCATE ALL SERVICABLE EQUIPMENT A MINIMUM OF 10'-0" AWAY
FROM BUILDING EDGE.
www.coffman.com
221 N. Wall Street, Suite 500
Spokane, WA 99201
ph 509.328.2994
32 MERCHANT STREET, SUITE 208
HONOLULU, HI 96813
808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND
VERIFY ALL DIMENSIONS AT JOB BEFORE
PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER
MY SUPERVISION AND CONSTRUCTION OF THIS
PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 99216MECHANICAL ROOF
PLAN
M-106
FSC PROJECT NO. 21012
PERMIT SET
MAY 30, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce Lane
Spokane, WA 99206
(509) 919-0901
3/32" = 1'-0"
MECHANICAL ROOF PLAN
0'6'12'24'
SCALE: 3/32" = 1'-0"
KEY NOTES
1 SECURE CONDENSING UNITS TO STANDS THAT ELEVATE UNITS
A MINIMUM OF 18" ABOVE ROOF LEVEL FOR SNOW CLEARANCE.
2 ERV-01 TO BE PROVIDED WITH A SIDE CONNECTION CURB.
SUPPLY AND EXHAUST DUCTS TO CONNECT TO CURB.
3 PROVIDE A WATER TIGHT CONNECTION AROUND DUCTS AT
ROOF PENETRATIONS.
Revision Schedule
Number Description Date
5/30/2024
MAAMMMAAM
M A
A
M
M
A
A
M
M A
A
M
M
A
A
K
7
6
EFFICIENCY
129
PTAC-01
1S
30
1E
35 4ø4øN P
7
6
DOUBLE QUEEN
135
PTAC-01
1S
50
4ø1E
55
C D
C.1
3
2.1
2
EFFICIENCY ENLARGED
203 PTAC-01
1S
30
1E
35
4ø
4øA B
8.1
8
7
6.1
DOUBLE QUEEN ENLARGED
212
PTAC-01
1S
50
1E
55
4ø4ø
C D
C.1
3
2.1
2
EFFICIENCY ENLARGED
303
PTAC-01
4ø
4ø
1E
35
1S
30
DOUBLE QUEEN ENLARGED
412
PTAC-01
A
A
B
B
6.1 6.1
7 7
8 8
8.1 8.1 4ø4ø
1E
55
1S
50
GENERAL NOTES
A. MOTORIZED DAMPERS SHALL BE PROVIDED TO EACH GUEST
ROOM PER WSEC C403.7.4.2 TO SERVE AS ISOLATION DEVICES
CAPABLE OF AUTOMATICALLY SHUTTING OFF THE SUPPLY OF
OUTDOOR AIR TO AND EXHAUST AIR FROM EACH GUEST ROOM.
CONSTANT VOLUME DAMPER SHALL BE INSTALLED IN DUCT
BRANCHES SERVING GUEST ROOMS, SET TO AUTOMATICALLY
CONTROL AIRFLOW TO THE VALUES SHOWN ON PLANS; BASIS-OF-
DESIGN IS ALDES CAR3.
B. GUEST ROOM HEATING AND COOLING PTAC UNITS SHALL BE
PROVIDED TO MEET WSEC C403.7.4.1 WITH CONTROLS
CONFIGURED TO AUTOMATICALLY RAISE THE SET POINTS.
C. REMOTE, WALL-MOUNTED, HARD-WIRED, ELECTRONIC DIGITAL
THERMOSTAT SPECIFICALLY DESIGNED FOR GUEST SUITE
APPLICATIONS MUST BE PROVIDED. STUDIO SUITES AND MULTI-
ROOM SUITES, SERVED BY A SINGLE HVAC UNIT, MUST HAVE THE
THERMOSTAT LOCATED IN THE MAIN SLEEPING AREA. GUEST
ROOMS SERVED BY MULTIPLE HVAC UNITS MUST HAVE A
THERMOSTAT FOR EACH HVAC UNIT LOCATED IN THE SPACE
SERVED BY THAT UNIT. BATTERY POWERED THERMOSTATS ARE
NOT ACCEPTABLE.
D. DUCTWORK DIRECTLY SERVING THE POOL AND POOL MEP ROOMS
SHALL BE CONSTRUCTED OF ALUMINUM.
E. DUCTS SHALL BE CONSTRUCTED OF MINIMUM 26-GUAGE STEEL.
DUCT PENETRATIONS THROUGH 1-HR (OR LESS) RATED FIRE
PARTITIONS IN GUEST CORRIDOR DO NOT REQUIRE FIRE
DAMPERS PER IBC 717.5.4 EXCEPTION 4.
www.coffman.com
221 N. Wall Street, Suite 500
Spokane, WA 99201
ph 509.328.2994
32 MERCHANT STREET, SUITE 208
HONOLULU, HI 96813
808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND
VERIFY ALL DIMENSIONS AT JOB BEFORE
PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER
MY SUPERVISION AND CONSTRUCTION OF THIS
PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 99216ENLARGED
MECHANICAL PLANS
M-401
FSC PROJECT NO. 21012
PERMIT SET
MAY 30, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce Lane
Spokane, WA 99206
(509) 919-0901
1/4" = 1'-0"1 ENLARGED PLAN - EFFICIENCY
1/4" = 1'-0"4 ENLARGED PLAN - DOUBLE QUEEN
1/4" = 1'-0"3 ENLARGED PLAN - EFFICIENCY ADA-M-RI
1/4" = 1'-0"5 ENLARGED PLAN - DOUBLE QUEEN ENLARGED
1/4" = 1'-0"2 ENLARGED PLAN - EFFICIENCY ENLARGED
1/4" = 1'-0"6 ENLARGED PLAN - DOUBLE QUEEN ADA-M-T
Revision Schedule
Number Description Date
5/30/2024
M
A
A
M
M
A
A
M
M
A
A
MMMAAMMAA
2.1
1.1
2
KING 1-BEDROOM
202
1E
55
1S
25
1S
25
PTAC-01
PTAC-01
4ø 4ø4ø
4ø
DC.1
1.1
2
KING 1-BEDROOM ENLARGED
201
PTAC-01
PTAC-01
1S
25
1S
30
1E
604ø 4ø
4ø
4ø
C DC.1
1.1
2
KING 1-BEDROOM ADA-M-T
301
PTAC-01
PTAC-01
1S
304ø
4ø4ø
4ø1S
25
1E
60
K L.1
9
8
KING STUDIO
130
PTAC-01
1S
35
1E
40 4ø4øP
9
8
KING STUDIO ADA-M-T
138
PTAC-01
1E
40
1S
35 4ø4øGENERAL NOTES
A. MOTORIZED DAMPERS SHALL BE PROVIDED TO EACH GUEST
ROOM PER WSEC C403.7.4.2 TO SERVE AS ISOLATION DEVICES
CAPABLE OF AUTOMATICALLY SHUTTING OFF THE SUPPLY OF
OUTDOOR AIR TO AND EXHAUST AIR FROM EACH GUEST ROOM.
CONSTANT VOLUME DAMPER SHALL BE INSTALLED IN DUCT
BRANCHES SERVING GUEST ROOMS, SET TO AUTOMATICALLY
CONTROL AIRFLOW TO THE VALUES SHOWN ON PLANS; BASIS-OF-
DESIGN IS ALDES CAR3.
B. GUEST ROOM HEATING AND COOLING PTAC UNITS SHALL BE
PROVIDED TO MEET WSEC C403.7.4.1 WITH CONTROLS
CONFIGURED TO AUTOMATICALLY RAISE THE SET POINTS.
C. REMOTE, WALL-MOUNTED, HARD-WIRED, ELECTRONIC DIGITAL
THERMOSTAT SPECIFICALLY DESIGNED FOR GUEST SUITE
APPLICATIONS MUST BE PROVIDED. STUDIO SUITES AND MULTI-
ROOM SUITES, SERVED BY A SINGLE HVAC UNIT, MUST HAVE THE
THERMOSTAT LOCATED IN THE MAIN SLEEPING AREA. GUEST
ROOMS SERVED BY MULTIPLE HVAC UNITS MUST HAVE A
THERMOSTAT FOR EACH HVAC UNIT LOCATED IN THE SPACE
SERVED BY THAT UNIT. BATTERY POWERED THERMOSTATS ARE
NOT ACCEPTABLE.
D. DUCTWORK DIRECTLY SERVING THE POOL AND POOL MEP ROOMS
SHALL BE CONSTRUCTED OF ALUMINUM.
E. DUCTS SHALL BE CONSTRUCTED OF MINIMUM 26-GUAGE STEEL.
DUCT PENETRATIONS THROUGH 1-HR (OR LESS) RATED FIRE
PARTITIONS IN GUEST CORRIDOR DO NOT REQUIRE FIRE
DAMPERS PER IBC 717.5.4 EXCEPTION 4.
www.coffman.com
221 N. Wall Street, Suite 500
Spokane, WA 99201
ph 509.328.2994
32 MERCHANT STREET, SUITE 208
HONOLULU, HI 96813
808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND
VERIFY ALL DIMENSIONS AT JOB BEFORE
PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER
MY SUPERVISION AND CONSTRUCTION OF THIS
PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 99216ENLARGED
MECHANICAL PLANS
M-402
FSC PROJECT NO. 21012
PERMIT SET
MAY 30, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce Lane
Spokane, WA 99206
(509) 919-0901
1/4" = 1'-0"3 ENLARGED PLAN - KING STUDIO 1 BEDROOM
1/4" = 1'-0"4 ENLARGED PLAN - KING 1 BEDROOM ENLARGED
1/4" = 1'-0"5 ENLARGED PLAN - KING 1 BEDROOM ADA-M-T
1/4" = 1'-0"1 ENLARGED PLAN - KING STUDIO
1/4" = 1'-0"2 ENLARGED PLAN - KING STUDIO ADA-M-T
Revision Schedule
Number Description Date
5/30/2024
CHANGE OF DUCT SIZE
TRANSITION
BRANCH DUCT TAKEOFFS
END TAP
A ≤ 15° FOR DUCTS W/ AIR
VELOCITY OVER 1,500 FPM.
A ≤ 30° FOR DUCTS W/ AIR
VELOCITY UNDER 1,500 FPM
RECTANGULAR
DUCT
DUCT ELBOWS
NOTE: OFFSETS (TO AVOID OBSTRUCTIONS) ARE REQUIRED BUT ARE
NOT NECESSARILY SHOWN ON THE PLANS.
OFFSETS
TURNING
VANES
R=1/2W FOR DUCTS W/ AIR
VELOCITY UNDER 1,500 FPM
R=W FOR DUCTS W/ AIR VELOCITY
OVER 1,500 FPM AND ALL DUCTS
UPSTREAM OF TERMINAL UNITS
45° OR 90°
RADIUS ELBOWS45.00°ROUND OR
RECTANGULAR
CONICAL
SPIN-IN
ROUND DUCT RUNOUT
TO SINGLE DIFFUSER
OR GRILLE ONLY45.00°DW
D=1/2W, BUT NOT MORE THAN
12" (1/3W PERMITTED IF AIR
VELOCITY UNDER 3,000 FPM)ACONICAL SPIN-IN OR TRANSITION
TO AT LEAST 70% GREATER THAN
AREA OF SMALLER DUCT. SEE MAX
TRANSITION ANGLE.
THE DUCT FITTINGS ABOVE ARE CONSIDERED ACCEPTABLE. THE CONTRACTOR SHALL OBTAIN ENGINEER'S APPROVAL FOR ALTERNATIVE FITTINGS
PRIOR TO FABRICATION. ONLY FITTINGS WITH EQUAL OR LOWER PRESSURE DROP WILL BE CONSIDERED.AW12"x12" ACCESS PANEL ON
BOTTOM OF DUCT
UPSTREAM OF TURNING
VANES, REQUIRED FOR
RETURN AND EXHAUST
DUCTS
(ONLY PERMITTED FOR AIR
VELOCITY UNDER 1,500 FPM)
A ≤ 15° FOR DUCTS W/ AIR
VELOCITY OVER 1,500 FPM.
A ≤ 30° FOR DUCTS W/ AIR
VELOCITY UNDER 1,500 FPM
R
AW
R
R=1/2W FOR DUCTS W/ AIR
VELOCITY UNDER 1,500
FPM
R=W FOR DUCTS W/ AIR
VELOCITY OVER 1,500 FPM
AND ALL DUCTS
UPSTREAM OF TERMINAL
UNITS
DUCT SUPPORT,
MIRO INDUSTRIES 6DS,
OR APPROVED EQUAL
SET SUPPORT ON
EXTRA LAYER OF
ROOFING MEMBRANE
INSULATE DUCTWORK
AS SPECIFIED
ROOFTOP DUCTWORK
PER PLANS
PROVIDE SHEET METAL
COVER, AND SEAL WATER TIGHT.
PROVIDE SEAMS ON BOTTOM AND
SIDES AS MUCH AS FEASIBLE
UNISTRUT SUPPORT ABOVE
AND BELOW DUCTWORK
NOTE:
SPACING NOT TO EXCEED 8' O.C.
DUCT SIZE, SEE PLANS
FLEXIBLE DUCT
CONNECTOR, TYP.
DUCT
SUPPLY FAN COIL
LIQUID
SUCTION
SEE FLOOR
PLANS FOR
ROUTING
SUPPORT FROM
STRUCTUREDOUBLE DEFLECTION SPRING
NEOPRENE HANGER, MASON MODEL
30N, OR APPROVED EQUAL
FABRICATED FILTER
BOX, SIDE ACCESS
RETURN
DUCT
1" PUMPED CONDENSATE
FROM FAN COIL
1" GRAVITY DRAIN
CONDENSATE
OUTSIDE
AIR DUCT
RIGID INSULATIONROOF DECK
DUCTROOFING
CANT STRIP
WOOD CURB
22 GA. FLASHING
COUNTERFLASHING
WEATHERSTRIP
WEATHERSEAL ALL
JOINTS AND SEAMS
NOTES:
1. LENGTH OF LEGS FOR DUCT SUPPORT FRAME VARIES WITH SLOPE OF THE ROOF. DUCT SHALL BE LEVEL.
2. LOCATION OF DUCT SUPPORT FRAME SHALL BE IN ACCORDANCE WITH DIVISION 15.
SECURE DUCT TO
SUPPORT
2X1X1/8 CHANNEL CROSS
MEMBER WELDED TO BOTH
LEGS TO SUPPORT DUCT.
2X1X1/8 CHANNEL LEG WELD
TO PLATE (TYP. OF 2, ONE ON
EACH SIDE)
6X6X3/8 STEEL PLATE
FASTENED TO BASEROOF
2x8 WOOD BASE, LENGTH 4" LONGER THAN
SUPPORT WIDTH, SET ON WALKING PAD OR
REINFORCED ROOFING, DO NOT SECURE
2500
1320
420ONE 1 x 18 GA STRAP36
ONE 1 x 16 GA STRAP
84
60
50 700
ONE 1 x 22 GA STRAP
QUANTITY/SIZE IN.MAX. DUCT
Ø IN.
26
HANGER STRAPS OR RODS
MAX. LOAD LBS.
260
MAX. SPACING
IN.
144
144
NOTE:
TABULATED DATA FROM SMACNA
ALLOWS FOR DUCT REINFORCING AND
INSULATION, BUT NO EXTERNAL LOAD.BAND OF SAME
SIZE AS HANGER
STRAP
LOAD RATED
FASTENERS
50" Ø & UNDER
144
144
144
TWO 3/8 Ø RODS
TWO 1/2 Ø RODS
18 GAUGE SHEET METAL COLLAR
FLANGE TIGHT AGAINST WALL
SURFACE. ATTACH TO DUCT WITH
SHEET METAL SCREWS OR POP RIVETS
PARTITION WALL
WALLBOARD
STUD FRAME OPENING
NOT BY MECHANICAL
SHEET METAL DUCT
NAILER STRIP
NEOPRENE GASKET
COUNTER FLASHING
NOTE:
ATTACH EQUIPMENT TO CURB PER MFR'S
INSTALLATION INSTRUCTIONS. SEE S-501
FOR
CURB TO STRUCTURE ATTACHMENT DETAIL.
SEE ARCHITECTURAL DETAILS FOR ROOFING
SCOPE.
PACKAGED ROOFTOP
AIR CONDITIONING
UNIT
VIBRATION ISOLATION
SPRINGS INCLUDED
WITH EQUIPMENT CURB
ROOF CURB
UNIT SIDE DUCT
CONNECTION, TYP.
FLEXIBLE DUCT
CONNECTION, TYP.
SUPPLY/
RETURN AIR
NOTE:
CONTRACTOR SHALL PROVIDE A DEFERRED
SUBMITTAL DETAILING ANCHORAGE OF UNIT TO
CURB AND CURB TO STRUCTURE.
CALCULATIONS AND DETAILS SHALL BE
STAMPED BY A STRUCTURAL ENGINEER
LICENSED IN THE STATE OF WASHINGTON.
SECURE EQUIPMENT TO STRUCTURE
WITH 8 GAUGE WIRE. FASTEN WITH 3
TIGHT TURNS IN 1". WIRE MAY BE SLACK.
TYP. ALL FOUR SIDES.
LOUVERED GRILLE WITH
SURFACE MOUNT FRAME
SPIN-IN CONNECTION
SEALANT
SHEET METAL BOOT, SEALANT
ON ALL SEAMS
TOP INLET, WHERE APPLICABLE
CONNECT SPIN-IN AS CLOSE AS
POSSIBLE TO TOP OF PLENUM
S.S. OR NYLON CLAMP
FLEXIBLE DUCT SIZE AS
INDICATED ON PLANS
SIDE INLET, WHERE
APPLICABLE
NOTE:
BOOT HEIGHT SHALL BE MIN. 8", WIDTH AND
LENGTH SHALL MATCH GRILLE FLANGE.
LAY-IN CEILING
SECURE EQUIPMENT TO STRUCTURE
WITH 8 GAUGE WIRE. FASTEN WITH 3
TIGHT TURNS IN 1". WIRE MAY BE SLACK.
TYP. ALL FOUR SIDES.
LOUVERED GRILLE
WITH LAY-IN FRAMESPIN-IN CONNECTION
SEALANT
SHEET METAL BOOT, SEALANT
ON ALL SEAMS
TOP INLET, WHERE APPLICABLE
CONNECT SPIN-IN AS CLOSE AS
POSSIBLE TO TOP OF PLENUM
S.S. OR NYLON CLAMP
FLEXIBLE DUCT SIZE AS
INDICATED ON PLANS
SIDE INLET,
WHERE APPLICABLE
NOTE:
BOOT HEIGHT SHALL BE MIN. 8", WIDTH AND
LENGTH SHALL MATCH GRILLE FLANGE.
GYP. BD.
SECURE EQUIPMENT TO
STRUCTURE WITH 12 GA.
WIRE. FASTEN WITH 3
TIGHT TURNS IN 1" WIRE
MAY BE SLACK. TYPICAL
ALL FOUR SIDES.
TRANSITION, WHERE REQ'D
SUPPLY DIFFUSER
S.S. OR NYLON CLAMP
FLEXIBLE DUCT
CEILING
R=1.5xø
PROVIDE SMOOTH
RADIUS CONNECTION,
PROPERLY SUPPORT FLEX
DUCT FOR SMOOTH AIR FLOW
TO DIFFUSER
SHEETMETAL DUCT
MAX SAG 1/2" PER FOOT
ON SUPPORT SPACING
FLEXIBLE INSULATED
NONMETALLIC DUCT, SIZE
AS INDICATED ON PLANS
SEE SPECS
1" WIDE SHEET METAL STRAP
SECURED TO STRUCTURE, SIZE AND
SPACING PER MECHANICAL CODE
www.coffman.com
221 N. Wall Street, Suite 500
Spokane, WA 99201
ph 509.328.2994
32 MERCHANT STREET, SUITE 208
HONOLULU, HI 96813
808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND
VERIFY ALL DIMENSIONS AT JOB BEFORE
PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER
MY SUPERVISION AND CONSTRUCTION OF THIS
PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 99216MECHANICAL DETAILS
M-501
FSC PROJECT NO. 21012
PERMIT SET
MAY 30, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce Lane
Spokane, WA 99206
(509) 919-0901
NTS1LOW PRESSURE DUCT FITTING REQUIREMENTS
NTS2OUTDOOR DUCT DETAIL - STAND
NTS5HORIZONTAL FAN COIL INSTALLATION - DUCTED RETURN
NTS7ROOF DUCT PENETRATION
NTS3OUTSIDE AIR DUCT SUPPORT DETAIL
NTS6ROUND DUCT HANGER
NTS4STUD WALL PENETRATION
NTS8ENERGY RECOVERY UNIT MOUNTING
NTS9TYP. RETURN/EXHAUST GRILLE MOUNTING
NTS10SUPPLY DIFFUSER INSTALLATION
Revision Schedule
Number Description Date
5/30/2024
CONDENSING UNIT
SECURE CONDENSING UNIT TO STAND PER
MANUFACTURER'S INSTRUCTIONS, TYP. OF 4
MANUFACTURER OUTDOOR UNIT STAND
ROOF FLASHING, SEE ARCHITECTURAL
ANCHOR BOLTS, TYP. OF 4 EACH LEG ROOF, SEE ARCHITECTURAL
CONDENSING UNIT
BEAM
RIGID INSULATION
SPRING ASSEMBLY, MASON INDUSTRIES
SLRSO-B-750. ONE AT EACH CORNER,
TYP. OF 4. LAG TO CURB WATER TIGHT,
USE RUBBER GROMMETS AND SEALANT
UNIT BASE RAIL
3/4" PLYWOOD
6" RIGID INSULATION
PER ARCH.
METAL ROOF DECK
INTERPLY
ROOFING MEMBRANE
SEAMLESS SHEET METAL
FLASHING/COVER
2x2x3/16" W/
(2) #10 TEK SCREWS @ 3" O.C. INTO DECK &
(2) #10 TEK SCREWS @ 3" O.C. INTO WOOD PLATFORM,
TYP. EA. CORNER OF UNIT
TREATED WOOD
CURBING, 3" MIN. WIDTH
1
2
KEYNOTES:
1. CONSTRUCT CURB ON ALL 4 SIDES. FIELD VERIFY NECCESSARY WOOD HEIGHT TO MAINTAIN
8" MIN. CURB HEIGHT ABOVE ROOF INSULATION.
2. 2x6 AT 3'-0" O.C. MAX, EVENLY SPACED, PERPENDICULAR TO LONG SIDE. SUPPORT
W/ SIMPSON LU HANGER AT EACH END.
VIBRO-ACOUSTICS IFB STEEL BASE,
SIZE TO MATCH CONDENSING UNIT
BOLT UNIT TO BASE PER MRF'S
RECOMMENDATIONS
www.coffman.com
221 N. Wall Street, Suite 500
Spokane, WA 99201
ph 509.328.2994
32 MERCHANT STREET, SUITE 208
HONOLULU, HI 96813
808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND
VERIFY ALL DIMENSIONS AT JOB BEFORE
PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER
MY SUPERVISION AND CONSTRUCTION OF THIS
PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 99216MECHANICAL DETAILS
M-502
FSC PROJECT NO. 21012
PERMIT SET
MAY 30, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce Lane
Spokane, WA 99206
(509) 919-0901
NTS1CONDENSING UNIT MOUNTING, OUTDOOR COMPONENT - AC UNITS
NTS2CONDENSING UNIT MOUNTING
Revision Schedule
Number Description Date
5/30/2024
M
M
DO
OUTSIDE
AIR
EXHAUST
AIR
OPEN/CLOSE
SMART THERMOSTAT
(HONEYWELL INNCOM)PTAC HILTON EDGE SYSEM
DI
AI
RENTAL STATUS
SETPOINT
S
S
S
OCCUPANCY
SENSOR
PATIO DOOR
SENSOR
DOOR SENSOR
DO
AO
ENABLE/DISABLE
SETPOINT
24V WIRING BY CONTROLS
CONTRACTOR, TYP.
PTAC
DO
AO
ENABLE/DISABLE
SETPOINT
T
ADDITIONAL OCCUPANCY SENSOR IN
SPECIFIED ROOMS ONLY (SEE PLANS)
PATIO DOOR IN SPECIFIED
ROOMS ONLY (SEE PLANS)
ADDITIONAL PTAC IN SPECIFIED
ROOMS ONLY (SEE PLANS)
ROOM LIGHTS
(SEE ELECTRICAL)
SEQUENCE OF OPERATION:
HILTON EDGE SYSTEM SHALL DETERMINE ROOM RENTAL STATUS, SMART THERMOSTAT SHALL DETECT ROOM OCCUPANCY
VIA BUILT-IN OCCUPANCY SENSORS AND GUESTROOM DOOR SIGNAL. PTAC SHALL MODULATE TO MEET SETPOINT USING
FACTORY CONTROLS.
UNRENTED, UNOCCUPIED MODE:
1. VENTILATION DAMPERS SHALL BE NORMALLY CLOSED. ONCE DAILY, DAMPERS SHALL OPEN FOR 60 MINUTES.
2. PTAC SETPOINTS SHALL RESET TO:
COOLING: 80°F (MIN.)
HEATING: 60°F (MAX.)
RENTED, OCCUPIED MODE:
1. VENTILATION DAMPERS SHALL BE OPEN TO PROVIDE OUTSIDE AIR AND EXHAUST.
2. PTAC SETPOINT SHALL RETURN TO OCCUPANT SETPOINT ANDL BE ADJUSTABLE BY THE GUEST. DEFAULT VALUES ARE:
COOLING: 75°F (MIN.)
HEATING: 70°F (MAX.)
RENTED, UNOCCUPIED MODE:
1. WITHIN 20 MINUTES OF OCCUPANTS LEAVING THE GUESTROOM, VENTILATION DAMPERS SHALL CLOSE .
2. WITHIN 30 MINUTES OF OCCUPANTS LEAVING THE GUESTROOM, PTAC SETPOINTS SHALL RESET TO:
COOLING: OCCUPANT SETPOINT +4°F (MIN.)
HEATING: OCCUPANT SETPOINT -4°F (MAX.)
PTAC SHALL BE DISABLED WHEN PATIO DOOR IS OPEN IF SENSOR HAS DETECTED DOOR OPEN FOR LONGER THAN 20
SECONDS. PTAC SHALL ENABLE AFTER SENSOR DETECTS DOOR CLOSED FOR LONGER THAN 20 SECONDS,
AO SETPOINT
DO ENABLE/DISABLE
DI STATUS
HEAT
EXCHANGER
AO SETPOINT
DO ENABLE/DISABLE
DI STATUS
DI
DP
DI
DPT
AI
FILTER
STATUS
OUTSIDE
AIR TEMP
H
C
AO
GAS
FURNACE
SUPPLY
AIR TEMP
T
AI
SUPPLY
AIR
EXHAUST
AIR
PAIDUCT
STATIC P AI DUCT
STATIC
EXHAUST
AIR
OUTSIDE
AIR
FIRE/SMOKE
DAMPER, TYP.
DUCT STATIC PRESSURE
SENSORS LOCATED
ACCORDING TO HVAC PLAN
SEQUENCE OF OPERATION:
SYSTEM SUPPLIES OUTSIDE AIR TO THE BUILDING AND REMOVES EXHAUST AIR, RECOVERING ENERGY TO PRE-CONDITION
THE OUTSIDE AIR. IT SHALL BE ENABLED WHILE THE BUILDING IS OCCUPIED AND OPERATE BASED ON PACKAGED FACTORY
CONTROLS.
SUPPLY AND EXHAUST FANS SHALL MODULATE TO MAINTAIN STATIC PRESSURE SETPOINT, AS MEASURED BY DUCT STATIC
PRESSURE SENSORS. GUEST ROOMS WILL HAVE DEMAND-CONTROLLED VENTILATION, WHERE DAMPERS WILL CLOSE
WHEN THE ROOM IS UNOCCUPIED AND RE-OPEN ONCE OCCUPANCY IS DETECTED.
MINIMUM SUPPLY TEMPERATURE: INTEGRATED GAS FURNACE SHALL ENABLE TO MAINTAIN SUPPLY AIR TEMPERATURE
LEAVING THE UNIT OF 55°F
AI SPACE
TEMPERATURE
OUTDOOR
UNIT
T
SPLIT AIR CONDITIONING UNIT CONTROL DIAGRAM
SEQUENCE OF OPERATION:
UNIT SHALL OPERATE WITH FACTORY CONTROLS TO MAINTAIN TEMPERATURE
SETPOINT AT TOP OF ELEVATOR SHAFT
INDOOR UNIT
SEQUENCE OF OPERATION:
EXHAUST FAN EF-02 SHALL BE INTERLOCKED WITH LV-02 TO PROVIDE CONTINUOUS VENTILATION AND EXHAUST AT THE
RATE SHOWN ON THE EQUIPMENT SCHEDULES. WHEN EF-02 IS ENABLED, DAMPER SHALL OPEN AND COMBINATION LOUVER
LV-02 SHALL OPEN. WHEN FAN IS DISABLED, DAMPER AND LOUVER SHALL SHUT.
UNIT HEATER UH-01 SHALL CYCLE TO MAINTAIN A TEMPERATURE OF 60°F (ADJ).
EF-02
M
LV-02
OUTSIDE AIR
UH-01
ROOM
EXHAUST
AIR
POOL
BATHROOM
EXHAUST
AIR MCU-01
EF-01
M
AHU-01
LV-01
MM
POOL
RETURN AIR
POOL
SUPPLY AIR DH-01
EXHAUST AIR
OUTSIDE AIR
CD TO
DRAIN
RS/RL
GAS
FLUE VENT
POOL WATER (BY
POOL CONTRACTOR)
SEQUENCE OF OPERATION:
AHU-01 SHALL BE SUPPLIED WITH FACTORY CONTROLLER AS INDICATED ON EQUIPMENT SCHEDULES AND IN
SPECIFICATIONS. THE FOLLOWING SEQUENCE SHALL BE EXECUTED FROM THAT CONTROLLER.
SYSTEM STARTUP: AFTER A SHORT INITIAL DELAY TO ALLOW THE SENSORS TO STABILIZE, THE BLOWER STARTS AND
OPERATES CONTINUOUSLY. THE SYSTEM SHALL BEGIN OR RESUME OPERATION BASED ON THE SEQUENCE BELOW:
AIRSIDE CONFIGURATION: THE SYSTEM CONTINUOUSLY DELIVERS THE SPECIFIED SUPPLY AIR VOLUME TO THE POOL AREA.
THE MINIMUM EXHAUST AIR VOLUME (EF-01 SETPOINT) AND OUTDOOR AIR VOLUME ARE SET TO MEET THE VALUES ON THE
EQUIPMENT SCHEDULES.
DEHUMIDIFICATION MODE: OCCURS WHEN THE RETURN AIR RELATIVE HUMIDITY IS ABOVE THE HUMIDITY SETPOINT AND
RETURN AIR DEWPOINT IS ABOVE DEWPOINT SETPOINT. THE COMPRESSOR ENTERS THE COMPRESSOR START SEQUENCE,
AND THE REHEAT OUTPUT WILL ADJUST TO MAINTAIN THE SPACE TEMPERATURE AT SET POINT YEAR-ROUND.
COOLING MODE: OCCURS WHEN THE RETURN AIR TEMPERATURE IS ABOVE THE ROOM TEMPERATURE SETPOINT.
ECONOMIZER COOLING WILL BE ENABLED. DURING ECONOMIZER COOLING, THE RETURN AIR DAMPER SHALL SHUT AND THE
EXHAUST FAN EF-01 SHALL INCREASE TO MAXIMUM SPEED ACCORDING TO THE EQUIPMENT SCHEDULE. ECONOMIZER
SHALL BE LOCKED OUT WHEN OUTSIDE AIR TEMPERATURE IS ABOVE 84F (ADJUSTABLE). IF ROOM TEMPERATURE SETPOINT
IS NOT ACHIEVED AFTER TEN MINNUTES (ADJUSTABLE), THEN THE COMPRESSOR STARTS AND EXCESS COMPRESSOR HOT
GAS IS DIVERTED TO THE OUTDOOR AIR COOLED CONDENSER CU-01 FOR UP TO 100% HEAT REJECTION AT SUMMER DESIGN
AMBIENT CONDITIONS
SPACE HEATING MODE: OCCURS WHEN THE RETURN AIR TEMPERATURE IS BELOW THE ROOM TEMPERATURE SETPOINT.
THE MICROPROCESSOR SPACE HEATING OUTPUT SIGNAL IS SENT TO THE DUCT HEATER DH-01. THE SIGNAL OUTPUT WILL
REGULATE BASED ON THE RETURN AIR TEMPERATURE TO MODULATE THE HEATING AT THE DUCT HEATER.
POOL WATER HEATING MODE: OCCURS WHEN THE RETURN POOL WATER TEMPERATURE IS BELOW THE POOL WATER
SETPOINT AND THE POOL WATER FLOW SWITCH OR MINIMUM TEMPERATURE DIFFERENTIAL IS SATISFIED. IF THE
COMPRESSOR IS ALREADY OPERATING DUE TO A DEHUMIDIFICATION OR AIR CONDITIONING DEMAND, THE CONTROL
VALVES WILL DIVERT THE COMPRESSOR HOT GAS THROUGH THE COAXIAL HEAT EXCHANGER TO HEAT THE POOL WATER,
WITH THE REMAINDER REJECTED AT THE AIR REHEAT COIL OR THE AC HEAT EXCHANGER. AUXLIIARY POOL WATER HEATER
WILL BE ENGAGED AS A SECOND STAGE AS NEEDED.
IF THERE IS NO PRE-EXISTING DEMAND FOR THE COMPRESSOR TO OPERATE, THE MICROPROCESSOR SENDS A SIGNAL TO
THE AUXILIARY POOL WATER HEATER (REMOTE BY OTHERS) TO OPERATE. THE COMPRESSOR WILL NOT OPERATE SOLELY
FOR A POOL WATER HEATING DEMAND UNLESS SPECIFICALLY CONFIGURED TO DO SO AT THE CONTROLLER. AUX POOL
HEAT CONTACT WILL BE CLOSED WITH INSUFFICIENT FLOW. IN ORDER TO PREVENT THE POOL FROM OVERHEATING, IT IS
RECOMMENDED THAT A FIELD-INSTALLED AQUASTAT (PROVIDED BY OTHERS)BE INSTALLED IN SERIES WITH THESE WIRES.
FIELD-INSTALLED POOL WATER TEMPERATURE SENSOR(S) ARE PROVIDED TO ENABLE THE SMART POOL FEATURE. THIS
FEATURE PROVIDES THE ABILITY TO ACTIVATE BOOSTER POOL WATER PUMP(S) FEEDING THE UNIT WHEN POOL WATER
HEATING IS IN DEMAND.
FREEZE PROTECTION: OCCURS WHEN THE SUPPLY AIR TEMPERATURE FALLS BELOW THE FREEZESTAT SETPOINT. EXHAUST
FAN EF-01 IS STOPPED AND OUTDOOR AIR DAMPER IS FULLY CLOSED. WHEN THE FREEZESTAT ALARM IS TRIPPED, IT MUST
BE MANUALLY CLEARED BY THE OPERATOR.
www.coffman.com
221 N. Wall Street, Suite 500
Spokane, WA 99201
ph 509.328.2994
32 MERCHANT STREET, SUITE 208
HONOLULU, HI 96813
808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND
VERIFY ALL DIMENSIONS AT JOB BEFORE
PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER
MY SUPERVISION AND CONSTRUCTION OF THIS
PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 99216MECHANICAL CONTROL
DIAGRAMS
M-601
FSC PROJECT NO. 21012
PERMIT SET
MAY 30, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce Lane
Spokane, WA 99206
(509) 919-0901
NTS1GUEST ROOM CONTROL SYSTEM
NTS2DEDICATED OUTSIDE AIR CONTROL SYSTEM (ERV-01)
NTS3SPLIT SYSTEM CONTROL DIAGRAM
NTS4POOL MEP CONTROL
NTS5AHU-01 CONTROL SYSTEM
Revision Schedule
Number Description Date
5/30/2024
AIR HANDLING UNIT SCHEDULE
TAG LOCATION SERVES MANUFACTURER /
MODEL
SUPPLY FAN COOLING CAPACITY HEATING CAPACITY UNIT ELECTRICAL REQUIREMENTS AIR FILTERS
SIZE (WxLxH)
UNIT
WT.
(LBS)
REMARKSTOTAL
CFM
HEATING
CFM
MIN
CFM MIN OA CFM ESP
(IN. WC)
SENS.
(MBH)
TOTAL
(MBH)
TOTAL
(MBH)GPM PSI #SIZE (IN)HP DRIVE VOLTS Ø MCA MOCP
AHU-01 POOL MEP 103 POOL/SPLASH PAD POOLPAK/
PCP-2600-PS-I 3,100 3,100 1,300 1,155 1 3.2 DIRECT 54.6 101.7 63 12 10 460 3 19 30 2 4" MERV 13 36.25x56.25x61 870 1, 2, 3
MAU-01 FOOD PREP 123 FOOD PREP HOOD CAPTIVEAIRE/
A1-D.500-15D 1,380 1,380 1,000 - 0.5 1 DIRECT 112 - - 208 3 5.1 15 825 4, 5
1.SUPPLY COMMANDPAK UNIT CONTROL SYSTEM. AHU WORKS IN CONJUNCTION WITH DUCT-MOUNTED HEATER IN SUPPLY DUCT AND EXHAUST FAN MOUNTED IN RETURN DUCT.
2.HEATING CAPACITY SHOWN IS FOR HEATING POOL WATER WITH REJECTED HEAT FROM THE UNIT WHEN COOLING/DEHUMIDIFYING. SUPPLY AIR HEATING IS ACHIEVED WITH DUCT HEATER DOWNSTREAM OF AHU.
3.OUTSIDE AIR WILL INCREASE TO MAXIMUM CFM WHEN ECONOMIZER MODE IS ACTIVATED.
4.MAKEUP AIR UNIT INCLUDES EVAPORATIVE MEDIA (2.6 GAL/HR) WITH FREEZE PROTECTION DRAIN KIT, IBT/MUA EVAP INTERLOCK, UNIT-MOUNTED VFD, AND MOTORIZED BACKDRAFT DAMPER.
5.MAKEUP AIR UNIT INCLUDES NATURAL GAS FURNACE. SEE DUCT HEATER SCHEDULE FOR FURNACE INFORMATION. PROVIDE WITH 3/4" GAS STRAINER. ENTIRE MUA SHALL BE MOUNTED ON A SINGLE RAIL FOR CEILING-SUSPENDED INSTALLATION.
VRF INDOOR UNIT SCHEDULE
TAG MFR /
MODEL OUTDOOR UNIT TYPE CFM ESP
(IN H20)
NOISE
(dBA)REFRIGERANT
CAPACITY (MBH)FILTERS ELECTICAL
WEIGHT
(LBS)NOTESTOTAL
COOLING
SENSIBLE
COOLING HEATING BOX MODEL MERV (QTY) SIZE VOLTS PHASE MCA MFS
FCU-211 MITSUBISHI/TRANE /
TPEFYP030MA145A CU-02 CEILING - CONCEALED (DUCTED)1271 0.6 31-39-43 R410A 25.3 24.2 25.3 FBM2-4-A 13 (2) 14 x 20 x 2
(1) 14 x 14 x 2 208 1 4.25 15 84 1, 2, 3, 4
FCU-212 MITSUBISHI/TRANE /
TPEFYP015MA144A CU-02 CEILING - CONCEALED (DUCTED)494 0.6 27-31-34 R410A 12.7 10.5 12.7 FBM2-4-A 13 (2) 14 x 20 x 2
(1) 14 x 14 x 2 208 1 2.88 15 58 1, 2, 3, 4
FCU-213 MITSUBISHI/TRANE /
TPEFYP048MA144A CU-02 CEILING - CONCEALED (DUCTED)1306 0.6 35-40-44 R410A 40.5 30.6 40.2 FBM2-4-A 13 (2) 14 x 20 x 2
(1) 14 x 14 x 2 208 1 4.38 15 86 1, 2, 3, 4
FCU-214 MITSUBISHI/TRANE /
TPEFYP036MA144A CU-02 CEILING - CONCEALED (DUCTED)1271 0.6 35-39-43 R410A 30.4 26.3 29.8 FBM2-3-A 13 (2) 14 x 20 x 2 208 1 4.25 15 67 1, 2, 3, 4
FCU-215 MITSUBISHI/TRANE /
TPEFYP096MH140A CU-02 CEILING - CONCEALED (DUCTED)2966 1 39-42-46 R410A 81.1 65.5 80.4 FBH4-4 13 (2) 14 x 20 x 2
(1) 14 x 14 x 2 208 1 8.2 15 221 1, 2, 3, 4
FCU-216 MITSUBISHI/TRANE /
TPEFYP054MA144A CU-02 CEILING - CONCEALED (DUCTED)1413 0.6 34-38-42 R410A 25.3 24.2 25.3 FBM2-4-A 13 (2) 14 x 20 x 2
(1) 14 x 14 x 2 208 1 4.38 15 84 1, 2, 3, 4
FCU-217 MITSUBISHI/TRANE /
TPEFYP015MA144A CU-02 CEILING - CONCEALED (DUCTED)494 0.6 27-31-34 R410A 12.7 10.5 12.7 FBM2-4-A 13 (2) 14 x 20 x 2
(1) 14 x 14 x 2 208 1 2.88 15 86 1, 2, 3, 4
FCU-311 MITSUBISHI/TRANE /
TPLFYP005FM140A CU-03 CEILING - CASSETTE (4-WAY)280 - 26-28-30 R410A 4.5 4.2 5.1 ---208 1 0.24 15 40 1, 2, 3, 4
FCU-324 MITSUBISHI/TRANE /
TPLFYP005FM140A CU-03 CEILING - CASSETTE (4-WAY)280 - 26-28-30 R410A 4.5 4.2 5.1 ---208 1 0.24 15 40 1, 2, 3, 4
FCU-323 MITSUBISHI/TRANE /
TPLFYP012FM140A CU-03 CEILING - CASSETTE (4-WAY)335 - 26-30-34 R410A 10.8 7.6 12.4 ---208 1 0.29 15 40 1, 2, 3, 4
FCU-322 MITSUBISHI/TRANE /
TPLFYP005FM140A CU-03 CEILING - CASSETTE (4-WAY)280 - 26-28-30 R410A 4.5 4.2 5.1 ---208 1 0.24 15 40 1, 2, 3, 4
FCU-333 MITSUBISHI/TRANE /
TPLFYP005FM140A CU-03 CEILING - CASSETTE (4-WAY)280 - 26-28-30 R410A 4.5 4.2 5.1 ---208 1 0.24 15 40 1, 2, 3, 4
FCU-332 MITSUBISHI/TRANE /
TPLFYP012FM140A CU-03 CEILING - CASSETTE (4-WAY)335 - 26-30-34 R410A 10.8 7.6 12.4 ---208 1 0.29 15 40 1, 2, 3, 4
FCU-343 MITSUBISHI/TRANE /
TPLFYP005FM140A CU-03 CEILING - CASSETTE (4-WAY)280 - 26-28-30 R410A 4.5 4.2 5.1 ---208 1 0.24 15 40 1, 2, 3, 4
FCU-342 MITSUBISHI/TRANE /
TPLFYP012FM140A CU-03 CEILING - CASSETTE (4-WAY)335 - 26-30-34 R410A 10.8 7.6 12.4 ---208 1 0.29 15 40 1, 2, 3, 4
FCU-353 MITSUBISHI/TRANE /
TPLFYP005FM140A CU-03 CEILING - CASSETTE (4-WAY)280 - 26-28-30 R410A 4.5 4.2 5.1 ---208 1 0.24 15 40 1, 2, 3, 4
FCU-352 MITSUBISHI/TRANE /
TPLFYP012FM140A CU-03 CEILING - CASSETTE (4-WAY)335 - 26-30-34 R410A 10.8 7.6 12.4 ---208 1 0.29 15 40 1, 2, 3, 4
FCU-321 MITSUBISHI/TRANE /
TPLFYP005FM140A CU-03 CEILING - CASSETTE (4-WAY)280 - 26-28-30 R410A 4.5 4.2 5.1 ---208 1 0.24 15 40 1, 2, 3, 4
FCU-325 MITSUBISHI/TRANE /
TPLFYP005FM140A CU-03 CEILING - CASSETTE (4-WAY)280 - 26-28-30 R410A 4.5 4.2 5.1 ---208 1 0.24 15 40 1, 2, 3, 4
FCU-326 MITSUBISHI/TRANE /
TPLFYP006FM140A CU-03 CEILING - CONCEALED (DUCTED)300 0.6 24-28-30 R410A 5.4 5.4 6.2 FBM2-1-A 13 (1) 14 x 25 x 2 208 1 1.75 15 40 1, 2, 3, 4
FCU-331 MITSUBISHI/TRANE /
TPLFYP005FM140A CU-03 CEILING - CASSETTE (4-WAY)280 - 26-28-30 R410A 4.5 4.2 5.1 ---208 1 0.24 15 40 1, 2, 3, 4
FCU-334 MITSUBISHI/TRANE /
TPLFYP005FM140A CU-03 CEILING - CASSETTE (4-WAY)280 - 26-28-30 R410A 4.5 4.2 5.1 ---208 1 0.24 15 40 1, 2, 3, 4
FCU-335 MITSUBISHI/TRANE /
TPLFYP006FM140A CU-03 CEILING - CONCEALED (DUCTED)300 0.6 24-28-30 R410A 5.4 5.4 6.2 FBM2-1-A 13 (1) 14 x 25 x 2 208 1 1.75 15 40 1, 2, 3, 4
FCU-341 MITSUBISHI/TRANE /
TPLFYP005FM140A CU-03 CEILING - CASSETTE (4-WAY)280 - 26-28-30 R410A 4.5 4.2 5.1 ---208 1 0.24 15 40 1, 2, 3, 4
FCU-344 MITSUBISHI/TRANE /
TPLFYP005FM140A CU-03 CEILING - CASSETTE (4-WAY)280 - 26-28-30 R410A 4.5 4.2 5.1 ---208 1 0.24 15 40 1, 2, 3, 4
FCU-345 MITSUBISHI/TRANE /
TPLFYP006FM140A CU-03 CEILING - CONCEALED (DUCTED)300 0.6 24-28-30 R410A 5.4 5.4 6.2 FBM2-1-A 13 (1) 14 x 25 x 2 208 1 1.75 15 40 1, 2, 3, 4
FCU-351 MITSUBISHI/TRANE /
TPLFYP005FM140A CU-03 CEILING - CASSETTE (4-WAY)280 - 26-28-30 R410A 4.5 4.2 5.1 ---208 1 0.24 15 40 1, 2, 3, 4
FCU-354 MITSUBISHI/TRANE /
TPLFYP005FM140A CU-03 CEILING - CASSETTE (4-WAY)280 - 26-28-30 R410A 4.5 4.2 5.1 ---208 1 0.24 15 40 1, 2, 3, 4
FCU-355 MITSUBISHI/TRANE /
TPLFYP006FM140A CU-03 CEILING - CONCEALED (DUCTED)300 0.6 24-28-30 R410A 5.4 5.4 6.2 FBM2-1-A 13 (1) 14 x 25 x 2 208 1 1.75 15 40 1, 2, 3, 4
FCU-421 MITSUBISHI/TRANE /
PEAD-A18AA9 CU-04 CEILING - CONCEALED (DUCTED)600 0.6 27-28-33-36 R410A 15.9 13.0 9.7 FBM2-2-A 13 (1) 14 x 20 x 2
(1) 14 x 14 x 2 208 1 -- 40 1, 2, 3, 4, 5
FC-500 MITSUBISHI/TRANE /
TPKA0A0121LA00A CU-05 WALL-MOUNTED 385 - 34-37-40-43 R410A 10.6 10.0 7.1 ---208 1 -- 40 1, 2, 3, 4, 5
1. CAPACITY RATINGS AT 80 F DB / 67 F WB INDOOR FOR COOLING; 70 F DB INDOOR FOR HEATING.
2. EACH INDOOR UNIT SHALL BE INDEPENDENTLY CAPABLE OF HEATING OR COOLING.
3. PROVIDE AND INSTALL CONDENSATE PUMP.
4. PROVIDE WITH REMOTE CONTROLLER.
5. POWERED BY OUTDOOR UNIT.
VRF REFRIGERANT CONTROLLER SCHEDULE
MFR /
MODEL
OUTDOOR MAX. NO.ELECTICAL WEIGHT
TAG TYPE UNIT MARK BRANCHES VOLTS PHASE MCA MOCP (LBS)NOTES
BCU-01 MITSUBISHI/TRANE /
TCMBM0108JA11NA MAIN CU-02 8 208 1 0.83 15 110 1, 2
BCU-02 MITSUBISHI/TRANE /
TCMBM1016JA11NA MAIN CU-03 16 208 1 1.57 15 110 1, 2
1. PROVIDE AND INSTALL CONDENSATE PUMP, X87-721 208/30V MAXIBLUE.
2. PROVIDE AND INSTALL DIAMONDBACK BALL VALVES BV-SERIES, 700 PSIG WORKING PRESSURE, FULL PORT, 410A RATED.
ELECTRIC UNIT HEATER SCHEDULE
TAG LOCATION MANUFACTURER/ MODEL AIRFLOW
(CFM)
ELECTRIC HEAT UNIT POWER
REQUIREMENTS UNIT
WT.
(LBS)
NOTESMIN CAP
(BTUh)
EAT
(˚F)
LAT
(˚F)kW VOLTS Ø FLA
UH-01 POOL MEP 103 QMARK/
MWUH7504 305 19,200 10 70 5.6 208 1 27.1 27 1,2
UH-02 STORAGE SHED QMARK/
MWUH7504 305 12,800 0 60 3.8 208 1 18.0 27 2
1. MOUNT HEATER MINIMUM OF 8'-0" ABOVE FLOOR LEVEL.
2. PROVIDE HEATER WITH WALL THERMOSTAT, SET TO MAINTAIN MINIMUM 55° IN ROOM.
ELECTRIC WALL HEATER SCHEDULE
TAG LOCATION MANUFACTURER/ MODEL BTU/H
ELECTRICAL
NOTESWATTS VOLTS PH
EH-11 STAIR 1
GROUND FLOOR
QMARK /
CWH1101DSF 3413 1,000 120 1 1, 2, 3, 4
EH-12 STAIR 2
GROUND FLOOR
QMARK /
CWH1101DSF 3413 1,000 120 1 1, 2, 3, 4
EH-21 STAIR 1
2ND FLOOR
QMARK /
CWH1101DSF 3413 1,000 120 1 1, 2, 3, 4
EH-22 STAIR 2
2ND FLOOR
QMARK /
CWH1101DSF 3413 1,000 120 1 1, 2, 3, 4
EH-31 STAIR 1
3RD FLOOR
QMARK /
CWH1101DSF 3413 1,000 120 1 1, 2, 3, 4
EH-32 STAIR 2
3RD FLOOR
QMARK /
CWH1101DSF 3413 1,000 120 1 1, 2, 3, 4
EH-41 STAIR 1
4TH FLOOR
QMARK /
CWH1101DSF 3413 1,000 120 1 1, 2, 3, 4
EH-42 STAIR 2
4TH FLOOR
QMARK /
CWH1101DSF 3413 1,000 120 1 1, 2, 3, 4
EH-51 STAIR 1
5TH FLOOR
QMARK /
CWH1101DSF 3413 1,000 120 1 1, 2, 3, 4
EH-52 STAIR 2
5TH FLOOR
QMARK /
CWH1101DSF 3413 1,000 120 1 1, 2, 3, 4
1. HEATER SHALL BE SET TO MAINTAIN A TEMPERATURE OF 60°F IN STAIRWELL.
2. CONTRACTOR TO SUPPLY DOCUMENTATION FOR ALL UNITS AS PER WSEC C103.6.
3. UNIT TO BE SUPPLIED AND INSTALLED IN ACCORDANCE WITH STATE AND LOCAL CODE.
4. PROVIDE WITH SURFACE MOUNT KIT.
www.coffman.com
221 N. Wall Street, Suite 500
Spokane, WA 99201
ph 509.328.2994
32 MERCHANT STREET, SUITE 208
HONOLULU, HI 96813
808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND
VERIFY ALL DIMENSIONS AT JOB BEFORE
PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER
MY SUPERVISION AND CONSTRUCTION OF THIS
PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 99216MECHANICAL
SCHEDULES
M-701
FSC PROJECT NO. 21012
PERMIT SET
MAY 30, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce Lane
Spokane, WA 99206
(509) 919-0901
Revision Schedule
Number Description Date
5/30/2024
EXHAUST FAN SCHEDULE
TAG LOCATION SERVES MANUFACTURER/ MODEL
DESCRIPTION FAN PERFORMANCE UNIT ELECTRICAL REQUIREMENTS UNIT WT.
(LBS)NOTESTYPE DRIVE FLOW (CFM)ESP
(" WC)SPEED (RPM)
NOISE
SONES HP VOLTS Ø MCA MOCP
EF-01 POOL MECHANICAL ROOM
ROOF
POOL/SPLASH PAD
EXHAUST
GREENHECK /
CUE-160-VG UPBLAST DIRECT
(ECM)3,100 0.5 1259 16.6 2 208 1 16 30 181 1, 2, 4, 5
EF-02 POOL MECHANICAL ROOM
ROOF
POOL MEP AND
RESTROOM EXHAUST
GREENHECK /
CUE-090-VG UPBLAST DIRECT
(ECM)355 0.4 1346 5.9 1/10 120 1 2 15 90 1, 2, 3, 5
EF-03 FOOD PREP EXTERIOR
WALL
FOOD PREP EXHAUST
HOOD
CAPTIVEAIRE/
DU85HFA UPBLAST DIRECT
(ECM)1,725 1 1370 12.3 3/4 230 1 171 6
EF-04 EMP RR EMP RR NUTONE /
6950 CEILING DIRECT 50 0.2 -4.0 - 120 1 1.5 15 5 7
EF-05 EMP RR ADA EMP RR ADA NUTONE /
6950 CEILING DIRECT 50 0.2 -4.0 - 120 1 1.5 15 5 7
1. PROVIDE WITH TOTALLY ENCLOSED MOTOR ENCLOSURE, NEMA-3R DISCONNECT SWITCH, 18" ROOF CURB, CURB SEAL, AND MODEL VCD-23-PB CONTROL DAMPER WITH 120 V ACTUATOR.
2. PROVIDE WITH CHEMICAL RESISTANT HI-PRO POLYESTER COATING ON ALL COMPONENTS IN THE AIRSTREAM, INCLUDING DAMPER.
3. PROVIDE WITH POTENTIOMETER DIAL FOR BALANCING.
4. PROVIDE WITH SPEED CONTROLLER THAT ACCEPTS 0-10 VDC INPUT FROM POOL AHU TO DRIVE MIN. OSA AND ECONOMIZER.
5. FAN SHALL RUN 24/7.
6. PROVIDE WITH THROUGH-WALL CURB, LOCKING HINGE KIT, GREASE DUCT CERAMIC SEAL, AND GREASE BOX.
7. FAN CONTROL BY MANUAL TIMER SWITCH IN WALL.
GRILLES, REGISTERS, DIFFUSERS SCHEDULE
GRILLE NECK PANEL THROW FRAME
TAG TYPE MFR MODEL SIZE SIZE SIZE PATTERN MATERIAL STYLE FINISH NOTES
1S SUPPLY PRICE SMCD 6x6 6Ø -4-WAY STEEL SURFACE B12
2S SUPPLY PRICE SMCD 6x6 6Ø 24x24 4-WAY STEEL LAY IN B12
3S SUPPLY PRICE SMCD 8x8 8Ø -4-WAY STEEL SURFACE B12
4S SUPPLY PRICE SMCD 8x8 8Ø 24x24 4-WAY STEEL LAY IN B12
5S SUPPLY PRICE SMCD 10x10 10Ø -4-WAY STEEL SURFACE B12
6S SUPPLY PRICE SMCD 10x10 10Ø 24x24 4-WAY STEEL LAY IN B12
7S SUPPLY PRICE SMCD 12x12 12Ø -4-WAY STEEL SURFACE B12
8S SUPPLY PRICE SMCD 12x12 12Ø 24x24 4-WAY STEEL LAY IN B12
9S SUPPLY PRICE 510 6x4 6Ø -180º STEEL SURFACE B12
10S SUPPLY PRICE SDS100 60x1 SLOT 10Ø -180º ALUM. SURFACE B12
1R RETURN PRICE 535 6x6 6x6 -- STEEL SURFACE B12
2R RETURN PRICE 535 8x8 8x8 -- STEEL SURFACE B12
3R RETURN PRICE 535 8x8 8x8 24x24 - STEEL LAY IN B12
4R RETURN PRICE 535 14x12 14x12 24x24 - STEEL LAY IN B12
5R RETURN PRICE 535 14x14 14x14 24x24 - STEEL LAY IN B12
6R RETURN PRICE 535 16x16 16x16 24x24 - STEEL LAY IN B12
7R RETURN PRICE 535 24x20 24x20 -- STEEL SURFACE B12
8R RETURN PRICE 630 22x22 22x22 -- ALUM. SURFACE B12
1E EXHAUST PRICE 535 6x6 6x6 -- STEEL SURFACE B12 3
2E EXHAUST PRICE 535 6x6 6x6 24x24 - STEEL LAY IN B12
3E EXHAUST PRICE 535 8x8 8x8 -- STEEL SURFACE B12 3
4E EXHAUST PRICE 535 10x10 10x10 24x24 - STEEL LAY IN B12
5E EXHAUST PRICE 535 12x12 12x12 24x24 - STEEL LAY IN B12
6E EXHAUST PRICE 535 14x14 14x14 24x24 - STEEL LAY IN B12
7E EXHAUST PRICE 535 12x12 12x12 -- ALUM. DUCT B12
1. SEE FLOOR PLANS FOR CONNECTION SIZE
2. PROVIDE WITH SINGLE DEFLECTION OPTION.
3. IN RESTROOMS, JANITOR, AND MECHANICAL ROOMS USE ALUMINUM INSTEAD OF STEEL.
SEISMIC AND VIBRATION CONTROL SEISMIC RESTRAINT PROVISIONS
TAG EQUIPMENT LEVEL RESTRAINTS BASE FLEXIBLE
CONNECTORS
VIBRATION
ISOLATORS
COMPONENT
IMPORTANCE
FACTOR
DEFLECTION
(IN)
SEISMIC SUPPORTS ARE REQUIRED FOR THIS PROJECT FOR ALL MECHANICAL AND ELECTRICAL EQUIPMENT
AND DISTRIBUTION SYSTEMS. SEISMIC RESTRAINT CALCULATIONS MUST BE PROVIDED BY THE PRODUCT
MANUFACTURER FOR ALL CONNECTIONS OF EQUIPMENT TO THE STRUCTURE. ALL RESTRAINING DEVICES
SHALL HAVE TESTING DATA TO VALIDATE MAXIMUM RESTRAINT RATINGS. PREAPPROVALS BASED ON
INDEPENDENT TESTING ARE PREFERRED TO PREAPPROVALS BASED ON CALCULATIONS. CALCULATIONS
(INCLUDING THE COMBINING OF TENSILE AND SHEAR LOADING) TO SUPPORT SEISMIC RESTRAINT DESIGNS
MUST BE STAMPED BY A REGISTERED PROFESSIONAL ENGINEER LICENSED IN WASHINGTON. THE
ENGINEERING ANALYSIS MUST INDICATE CALCULATED DEAD LOADS, STATIC SEISMIC LOADS, AND CAPACITY
OF MATERIALS UTILIZED FOR CONNECTIONS TO EQUIPMENT STRUCTURE. ANALYSIS MUST DETAIL
ANCHORING METHODS, BOLT DIAMETER, EMBEDMENT, AND/OR WELDED LENGTH.
AHU-01 POOL AIR HANDLING UNIT GRADE A B Y 1.5
ERV-01 ENERGY RECOVERY DOAS UNIT ROOF A D Y 1.5
CU-01 POOL CONDENSING UNIT ROOF A B NR 1.5
CU-02 VRF HEAT RECOVERY CONDENSING UNIT ROOF A B NR 1.5
CU-03 VRF HEAT RECOVERY CONDENSING UNIT ROOF A B NR 1.5
CU-04 HEAT PUMP CONDENSING UNIT ROOF A B NR 1.5
CU-05 HEAT PUMP CONDENSING UNIT ROOF A B NR 1.5
ALL SEISMIC RESTRAINT DEVICES SHALL BE DESIGNED TO ACCEPT, WITHOUT FAILURE, THE FORCES
PRESCRIBED PER THE ASCE 7 ACTING THROUGH THE EQUIPMENT CENTER OF GRAVITY. OVERTURNING
MOMENTS MAY EXCEED FORCES AT GROUND LEVEL AND MAY BE RESISTED BY SEISMIC RESTRAINTS,
SUPPORT, OR ANCHORAGE. ANCHORAGE TO CONCRETE MUST HAVE AN ICC TESTING REPORT THAT
ADHERES TO THE REQUIREMENTS OF THE IBC AND MUST BE RATED FOR SEISMIC RESTRAINT IN CRACKED
CONCRETE USING THE APPROPRIATE REDUCTION FACTORS PER ACI 318 APPENDIX D. ACCEPTABLE
ANCHORS INCLUDE THE HILTI KWIK BOLT TZ AND SIMPSON STRONG BOLT WEDGE ANCHORS OR HILTI HIT-RE
500-SD AND SIMPSON SET XP EPOXY ANCHORS. EPOXIES ARE NOT ACCEPTABLE FOR USE IN OVERHEAD
APPLICATIONS.
BCU-01 VRF BRANCH CONTROLLER UNIT 1ST CEILING A A NR 1.5
BCU-02 VRF BRANCH CONTROLLER UNIT 2ND CEILING A A NR 1.5
FCU-xx VRF DUCTED FAN COIL UNIT 1-5 CEILING A A NR 1.5
FCU-xx VRF CEILING CASSETTE 1-5 CEILING A A NR 1.5
FCU-500 WALL-MOUNTED HEAT PUMP UNIT 5TH FLOOR A NA NR 1.5
WH-01-04 DOMESTIC WATER HEATER GRADE A NR NR 1.5
EF-01 POOL EXHAUST FAN 2ND ROOF A D Y 1 ASCE 7-16 SEISMIC DESIGN CRITERIAEF-02 POOL MEP RM EXHAUST FAN 2ND ROOF A D Y 1
EF-03 FOOD PREP EXHAUST FAN 1ST CEILING A B Y 1 SEISMIC DESIGN CATEGORY "C"
EF-04 BATHROOM EXHAUST FAN 1ST CEILING A A Y 1 RISK CATEGORY II
EF-05 BATHROOM EXHAUST FAN 1ST CEILING A A Y 1 SITE CLASS "D"
SEISMIC IMPORTANCE FACTOR FOR BUILDING, I = 1.0
DH-01 GAS DUCT HEATER 1ST CEILING A A Y 1.5 COMPONENT RESPONSE MODIFICATION AND AMPLIFICATION FACTORS
SHALL BE DETERMINED IN ACCORDANCE WITH ASCE 7, TABLE 13.6-1.
DESIGN SPECTRAL RESPONSE ACCELERATION AT SHORT PERIODS (0.2 SECOND):
SDS = 0.324 G.
DESIGN SPECTRAL RESPONSE ACCELERATION AT 1-SECOND PERIOD:
SD1 = 0.177 G.
RESTRAINTS BASE TYPE NOTES
A = ANCHOR A = ISOLATOR ATTACHED TO EQUIPMENT DIRECTLY 1 CONCRETE PAD MASS TO EQUAL AT LEAST 75% OF EQUIPMENT
AM = ANCHOR SPECIFIED BY EQUIPMENT MANUFACTURER B = STRUCTURAL STEEL RAILS OR BASE 2 NR=NOT REQUIRED, NA=NOT APPLICABLE
B = RESTRAINING BASE WITH SNUBBER C = CONCRETE INERTIA BASE 3 PIPING TO BE BRACED LATERALLY A MINIMUM OF EVERY 40' AND LONGITUDINALLY EVERY 80' REGARDLESS
OF SEISMIC REQUIREMENTS.Y = REQUIRED PER SPECIFICATION 23 05 40 D = CURB-MOUNTED BASE
ISOLATOR TYPE 4 SEE SPECIFICATION SECTION 23 05 40 FOR DESCRIPTION AND REQUIREMENTS OF BASES, ISOLATORS, AND
RESTRAINTS.
1. PAD: RUBBER, GLASS FIBER 4. RESTRAINED SPRING ISOLATOR 5 ALL PIPING GREATER THAN 1" MUST BE RESTRAINED
2. RUBBER ISOLATOR, FLOOR OR HANGER 5. THRUST RESTRAINT 6 EQUIPMENT VENDOR TO DETERMINE DEFLECTION
3. SPRING ISOLATOR, FLOOR OR HANGER 6. AIR SPRING
COMPONENT IMPORTANCE FACTOR
IF ONE OF THE FOLLOWING APPLY USE 1.5, OTHERWISE USE 1.0
1. THE COMPONENT IS REQUIRED TO FUNCTION FOR LIFE-SAFETY PURPOSES AFTER AN EARTHQUAKE, INCLUDING FIRE PROTECTION, SPRINKLER SYSTEMS AND EGRESS STAIRWAYS
2. THE COMPONENT CONVEYS, SUPPORTS, OR CONTAINS TOXIC OR EXPLOSIVE SUBSTANCES
3. THE COMPONENT IS IN OR ATTACHED TO A RISK CATEGORY IV STRUCTURE AND IT IS NEEDED FOR CONTINUED OPERATION OF THE FACILITY
4. THE COMPONENT CONVEYS, SUPPORTS, OR CONTAINS HAZARDOUS SUBSTANCES
PACKAGE TERMINAL AIR CONDITIONER (HEAT PUMP) SCHEDULE
TAG LOCATION MANUFACTURER/
MODEL
UNIT PERFORMANCE UNIT ELECTRICAL REQUIREMENTS UNIT
WT.
(LBS)
NOTESCFMCOOLING
(BTU/H)MIN EER HEATING
(BTU/H)MIN COP SUPPL.
HEAT kW VOLTS Ø MCA MOCP
PTAC-01 GUEST ROOM AMANA/
HEH093J35AXXXAA 307/335 9,000 13.00 8,000 3.78 3.0 208 1 19.5 20 106 1,2
1. PLUG-IN 208V 1-PH HEAT PUMP PTAC UNIT. REFRIGERANT MUST MEET WASHINGTON MAXIMUM 750 GWP.
2. PROVIDE WITH ELECTRIC HEAT ACCESSORY, HEAVY SOUND ISOLATION INSULATION SLEEVE, CONDENSATE DRAIN KIT, WIRE HARNESS KIT, AND ARCHITECTURAL OUTDOOR GRILLE (COORDINATE COLOR WITH ARCHITECT).
GAS-FIRED DUCT HEATER
TAG SERVES MANUFACTURER/ MODEL
AIRFLOW INPUT
MBH
OUTPUT
MBH
DUCT DIMENSIONS (IN)UNIT ELECTRICAL
REQUIREMENTS UNIT
WT.
(LBS)
NOTESCFMEAT (F) LAT (F)WIDTH HEIGHT VOLTS Ø FLA
DH-01 AHU-01
SUPPLY
REZNOR/
EEDU-TSL-200 3100 49.6 95 200 141 22.5 18 115 1 2 172 1,2,3
MAU-01 MAU-01 CAPTIVEAIR/
A1-D.500-15D 1380 10 95 122 112 - - - - - - 1,3,4
1. PROVIDE WITH A HIGH LIMIT SAFETY SHUT-OFF, COMBUSTION AIR PRESSURE SWITCH, AIR-PROVING SWITCH, COMBINATION GAS VALVE WITH SHUTOFF.
2. DUCT HEATER SHALL BE MINIMUM 2-STAGE AND PROVIDED WITH THERMOSTAT TO BE INSTALLED IN THE OCCUPIED ZONE.
3. PROVIDE NECESSARY FLUE VENT/ OA INTAKE PIPING PER MANUFACTURER'S INSTALLATION INSTRUCTIONS.
4. GAS FURNACE IS PART OF PACKAGED MAKEUP AIR UNIT, INFORMATION SHOWN HERE FOR CLARITY.
LOUVER SCHEDULE
TAG SERVES MANUFACTURER/ MODEL MATERIAL FRAME TYPE AIRFLOW
(CFM)
LOUVER
SIZE, WxH
(IN)
FACE
AREA
(SF)
FACE
VELOCITY
(FPM)
FREE
AREA
(SF)
FREE AREA
VELOCITY
(FPM)
APD
(IN WC)
DRAINABLE
BLADE
(YES/NO)
BLADE
ANGLE
(DEG)
FRAME
DEPTH (IN)
WEIGHT
(LBS)
BOTTOM OF
LOUVER
ELEVATION
NOTES
LV-01 POOLPAK
INTAKE
GREENHECK/
ESJ-401 ALUMINUM FIXED 3,100 44 x 44 13.44 231 6.60 469 0.04 NO 45 4 38 1,2
LV-02 POOLPAK
EXHAUST
GREENHECK/
ESJ-401 ALUMINUM FIXED 3,100 44 x 44 13.44 231 6.60 469 0.04 NO 45 4 38 1,2
LV-03 POOL MECH
INTAKE
GREENHECK/
EAC-401 ALUMINUM COMBINATION 355 20 x 20 2.78 128 0.80 459 0.03 YES 45 4 11 1,2,3
LV-04 LAUNDRY
MAKE-UP AIR
GREENHECK/
EAC-401 ALUMINUM COMBINATION 2,400 48 x 28 9.33 257 3.49 688 0.06 YES 45 4 28 1,2,3
LV-05 MAU-01 GREENHECK/
EDK-401 ALUMINUM FIXED 1,380 36 x 22 5.50 251 2.45 586 0.05 4 19 1,2
1. PROVIDE W/ INTERNAL ALUMINUM BIRD SCREEN.
2. COORDINATE FINAL LOUVER COLOR AND FINISH WITH OWNER PRIOR TO PURCHASE.
3. COMBINATION LOUVER PROVIDED WITH 24V, TWO-POSITION, FAIL-CLOSED, ACTUATOR TO BE INTERLINKED WITH EXHAUST FAN/DRYER EXHAUST OPERATION.
DAMPER SCHEDULE
TAG LOCATION SERVES MANUFACTURER/
MODEL TYPE WIDTH
(IN)
HEIGHT
(IN)
FLOW
(CFM)
FIRE
RATING
LEAKAGE
CLASS
CLOSE
TEMP
UNIT POWER
REQUIREMENTS NOTES
VOLTS Ø FLA
FD-11 LINEN
DISCHARGE
RM RETURN
AIR
RUSKIN/
FDR25 FIRE 8Ø 165 1.5 HR CLASS I 165 - - - 1
FD-12 LINEN
DISCHARGE
RM SUPPLY
AIR
RUSKIN/
FDR25 FIRE 6Ø 100 1.5 HR CLASS I 165 - - - 1
FSD-11 GROUND
FLOOR SHAFT
ERV-01
EXHAUST
RUSKIN/
FSD60 FIRE/SMOKE 22 18 2,555 1.5 HR CLASS I 165 120 1 - 1
FSD-12 GROUND
FLOOR SHAFT
ERV-01
SUPPLY
RUSKIN/
FSD60 FIRE/SMOKE 22 18 2,555 1.5 HR CLASS I 165 120 1 - 1
FSD-21 2ND FLOOR
SHAFT
ERV-01
EXHAUST
RUSKIN/
FSD60 FIRE/SMOKE 26 10 1,365 1.5 HR CLASS I 165 120 1 - 1
FSD-22 2ND FLOOR
SHAFT
ERV-01
SUPPLY
RUSKIN/
FSD60 FIRE/SMOKE 26 10 1,365 1.5 HR CLASS I 165 120 1 - 1
FSD-31 3RD FLOOR
SHAFT
ERV-01
EXHAUST
RUSKIN/
FSD60 FIRE/SMOKE 26 10 1,365 1.5 HR CLASS I 165 120 1 - 1
FSD-32 3RD FLOOR
SHAFT
ERV-01
SUPPLY
RUSKIN/
FSD60 FIRE/SMOKE 26 10 1,365 1.5 HR CLASS I 165 120 1 - 1
FSD-41 4TH FLOOR
SHAFT
ERV-01
EXHAUST
RUSKIN/
FSD60 FIRE/SMOKE 26 10 1,365 1.5 HR CLASS I 165 120 1 - 1
FSD-42 4TH FLOOR
SHAFT
ERV-01
SUPPLY
RUSKIN/
FSD60 FIRE/SMOKE 26 10 1,365 1.5 HR CLASS I 165 120 1 - 1
FSD-51 5TH FLOOR
SHAFT
ERV-01
EXHAUST
RUSKIN/
FSD60 FIRE/SMOKE 26 10 1,365 1.5 HR CLASS I 165 120 1 - 1
FSD-52 5TH FLOOR
SHAFT
ERV-01
SUPPLY
RUSKIN/
FSD60 FIRE/SMOKE 26 10 1,365 1.5 HR CLASS I 165 120 1 - 1
1. FAIL CLOSED
www.coffman.com
221 N. Wall Street, Suite 500
Spokane, WA 99201
ph 509.328.2994
32 MERCHANT STREET, SUITE 208
HONOLULU, HI 96813
808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND
VERIFY ALL DIMENSIONS AT JOB BEFORE
PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER
MY SUPERVISION AND CONSTRUCTION OF THIS
PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 99216MECHANICAL
SCHEDULES
M-702
FSC PROJECT NO. 21012
PERMIT SET
MAY 30, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce Lane
Spokane, WA 99206
(509) 919-0901
Revision Schedule
Number Description Date
5/30/2024
DEDICATED OUTDOOR AIR UNIT SCHEDULE
TAG LOCATION SERVES MANUFACTURER /
MODEL
SUPPLY FAN EXHAUST FAN ENERGY RECOVERY MODULE COOLING CAPACITY HEATING CAPACITY UNIT ELECTRICAL REQUIREMENTS AIR FILTERS
SIZE (WxLxH)
UNIT
WT.
(LBS)
NOTESTOTAL CFM ESP
(IN. WC)
MOTOR DATA TOTAL
CFM ESP
("WC)
MOTOR DATA OAT
DB/WB (°F)
LAT
DB/WB (°F)
OAT
DB/WB (°F)
LAT
DB/WB (°F)
SENS.
(MBH)
TOTAL
(MBH)
EDB
(F)
EWB
(F)
LAT
(F)
EFF.
(%)
INPUT
(MBH)
OUTPUT
(MBH)AFUE (%)# MERVBHP HP RPM DRIVE BHP HP RPM DRIVE VOLTS Ø MCA MOCP
ERV-01 ROOF HOTEL AAON /
RNA-026-D-A-8 8200 1.6 10.2 7.5 1302 DIRECT 8200 1.6 5.84 5 1250 DIRECT 96/63 90.7/63 57.1/50.4 24.2/24.1 121 21.6 96 63 80 109.6 550 440 80 208 3 88.00 125 8 8 - EA
13 - OSA 100x209x87 5067 1,2,3,4,5,6
1. UNIT HAS ENERGY RECOVERY WHEEL.
2. PROVIDE UNIT WITH 36" ROOF CURB WITH SIDE CONNECTIONS FOR SUPPLY AND EXHAUST. ROOF CURB SHALL INCLUDE INSULATION OR INSULATION PANELS AND SPRING ISOLATORS ACCORDING TO VIBRATION SCHEDULE.
3. PROVIDE DOAS WITH BOTTOM CONNECTIONS AND 24V MOTORIZED ISOLATION DAMPERS FOR EXHAUST AND OUTSIDE AIR. PROVIDE WEATHERHOODS ON OA INTAKE AND EXHAUST OUTLET.
4. PROVIDE MODULATING GAS MODULE WITH 10:1 TURNDOWN RATIO.
5. PROVIDE MODULATING SUPPLY AND EXHAUST FANS WITH VFDS.
6. PROVIDE WITH 10k SCCR RATING AND INTEGRAL DISCONNECT.
OUTDOOR CONDENSING UNIT SCHEDULE
TAG MFR /
MODEL TYPE UNIT SIZE
(TONS)REFRIGERANT REFRIGERANT
CHARGE (LBS)
TOTAL COOLING
CAPACITY (MBh)
SENSIBLE COOLING
CAPACITY (MBh)
HEATING
CAPACITY (MBh)
EER (MIN)
[SEER]IEER (MIN)
COP (MIN)
@ 47°F
[HSPF]
SOUND
PRESS.
ELECTRICAL
WEIGHT
(LBS)AREA SERVED NOTESVOLTS PHASE MCA MOCP
CU-01 POOLPAK /
NC-Z-1V
REMOTE AIR-COOLED
CONDENSER 5 R-410A -102 54.6 127 - -- 60 460 3 3 15 150 POOL 2, 6, 7
CU-02 MITSUBISHI/TRANE /
TURYH2404BN41AN
VRF HEAT RECOVERY
HEAT PUMP 20 R-410A 49.0 213 -211 19.6 9.85 3.46 87.5/88.5 460 3 35 50 1500 GROUND FLOOR 1, 2, 3, 4, 5, 6, 7
CU-03 MITSUBISHI/TRANE /
TURYH1444BN41AN
VRF HEAT RECOVERY
HEAT PUMP 6 R-410A 56.9 128 -150 20.65 11.15 3.63 78.5/80 460 3 25 40 1250 LINEN ROOMS, ELEVATOR
LOBBIES, AND CORRIDORS 1, 2, 3, 4, 5, 6, 7
CU-04 MITSUBISHI/TRANE /
TRUZA0181KA70NA REMOTE HEAT PUMP 1.5 R-410A -16 -10 [14.3] - [10] 44/46 208 3 11 28 150 SERVER ROOM 1, 3, 4, 6, 7
CU-05 MITSUBISHI/TRANE /
TRUZA0121KA70NA REMOTE HEAT PUMP 1 R-410A -11 -7 [21] - [10.2] 44/46 208 3 11 28 150 ELEVATOR MACHINE SPACE 1, 3, 4, 6, 7
1. PERFORMANCE AT 0 F WINTER AND 100 F DB / 64 F WB SUMMER. OPERATING RANGE: HEATING -22 F DB TO 60 F DB, COOLING 23 F DB TO 126 F DB.
2. UNIT IS COMPOSED OF TWO MODULES. SEPARATE POWER CONNECTION REQUIRED FOR EACH INDIVIDUAL MODULE: ELECTRICAL INFORMATION SHOWN IS FOR ONE MODULE.
3. ADDITIONAL REFRIGERANT CHARGE TO BE DETERMINED BY MECHANICAL CONTRACTOR AND EQUIPMENT MANUFACTURER.
4. SEE SYSTEM TREE FOR PIPE SIZES.
5. PROVIDE WITH MODEL TWINNING KIT.
6. PROVIDE WITH STANDS SIZED FOR THIS CONDENSING UNIT. 24" TALL, AND 1" DEFLECTION SPRING ISOLATORS, QUANITITY AND SIZE TO BE DETERMINED BY MANUFACTURER.
7. PROVIDE WITH SNOW/HAIL GUARDS KIT.
www.coffman.com
221 N. Wall Street, Suite 500
Spokane, WA 99201
ph 509.328.2994
32 MERCHANT STREET, SUITE 208
HONOLULU, HI 96813
808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND
VERIFY ALL DIMENSIONS AT JOB BEFORE
PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER
MY SUPERVISION AND CONSTRUCTION OF THIS
PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 99216MECHANICAL
SCHEDULES
M-703
FSC PROJECT NO. 21012
PERMIT SET
MAY 30, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce Lane
Spokane, WA 99206
(509) 919-0901
Revision Schedule
Number Description Date
5/30/2024
FDFDD D D DWWWWFDFDD D D DWWWWABCDC.1EFGHJKL.1MNPQ98.1876.16543.132.11.12COGWCO & V111GREASE INTERCEPTOR2" W UP3" W UP2" W UP2" W4" W4" W4" W4" W4" W4" W4" W4" W4" W4" W11111SP-1SP-218"X18"X18"SUMP2112" W2" W6" W4" W2" WCOG5" RD UP4" W4" W4" W4" W UP2" W4" WFCO2" WFD4" W4" W UPHUB DRAIN3/4" G3" G3" G3/4" G1/2" G3/4" G1/2" G1/2" G3" GDF-12" W1 1/2" V2" V4" WWCO3" W4" W4" W4" W4" WFSFSBF-16" CW, SEE CIVIL FOR CONTINUATION 6" W6" W6" W4" WBF-14" W6" W2" W2" V1 1/2" V4" W4" W4" W4" W3" VFDFSWCO2" W UP TO WCO THEN 2" V UP2" V UP2" V UP2" W UP TO WCO THEN 2" V2" PW34" RAD4" RAD4" RAD4" RAD4" RAD6" RAD6" RAD6" RAD4" RAD6" RAD4" RAD4" RAD4" RAD4" RAD4" RAD8" RAD UP1/2" G TO PRE-MANUFACTURED FIREPIT1/2" G TO PRE-MANUFACTURED FIREPIT1/2" G TO BARBEQUE1-1/2" G TO GENERATOR, SEE ELECTRICAL PLANS FOR LOCATION -PROVIDE ISOLATION VALVE (REGULATOR BY VENDOR)2" W2" W2" W6" W2" W, TYP.3" RD3" RD3" RDFSFS2" VMIN. 5'-0"5" RD5" RDI.E. = 3'-11" BFFSEE CIVIL PLANS FOR CONTINUATIONI.E. = 3'-6" BFFSEE CIVIL PLANS FOR CONTINUATIONI.E. = 3'-5" BFFSEE CIVIL PLANS FOR CONTINUATION2" WI.E. = 4'-4" BFFSEE CIVIL PLANS FOR CONTINUATION2" V2" W2" W2" W3" W3" W2" W2" W2" W3" W2" W2" W2" W2" V2" V2" W2" W3" W2" V2" V2" V2" V2" VCOCOCO44224" RD = 3'-6" BFF.SEE CIVIL PLANS FOR CONTINUATION.2GENERAL UNDERSLAB PLUMBING NOTESA. ALL PIPING SHALL BE SLEEVED AND SEALED THROUGH ANY STRUCTURE OR CONCRETE. B. WASTE AND VENT PIPING SHALL BE NO-HUB CAST IRON OR SCHEDULE 40 PVC DWV.C. SLOPE ALL BELOW GRADE SANITARY AND RAIN DRAIN PIPING AT 1/4" PER FOOT, MIN. UNO.D. TRAP PRIMER PIPING NOT SHOWN FOR CLARITY. SEE FLOOR PLANS FOR WATER AND DRAIN LOCATIONS, AND PLUMBING FIXTURE SCHEDULE FOR PRIMER REQUIREMENTS.E. CONTRACTOR TO BLOCK OUT/SLEEVE CONCRETE STEM WALLS WHERE REQUIRED TO ACCOMMODATE PIPING (OR CORE DRILL AFTER CONCRETE IS POURED).F. ALL RADON PIPING NOT BURIED BELOW SLAB SHALL BE SCHEDULE 40 PVC OR SCHEDULE 40 ABS, AND CLEARLY LABELED "RADON PIPE". ALL JOINTS AND CONNECTIONS MUST BE GAS TIGHT. ANY HORIZONTAL RADON VENT PIPE MUST BE SLOPED TO PROVIDE DRAINAGE TO GROUND UNDER SLABG. ALL RADON PIPING BURIED BELOW SLAB SHALL BE ADS DOUBLEWALL CORRUGATED POLYETHYLENE N-12 PERFORATED PIPE. TOP OF PIPE SHALL BE 1" BELOW BOTTOM OF SLAB. EMBED IN 3/8" PEA GRAVEL MIN 4" ALL AROUND. CAP ALL PIPE ENDS.H. ALL BURIED GAS PIPING TO BE POLYETHYLENE (PE) WITH TRACER WIRE INSTALLED 6" ABOVE. GROUND COVER TO BE A MINIMUM OF 18". INSTALL PER 2021 IFGC. ALL EXPOSED GAS PIPING TO BE SCH. 40 BLACK STEEL. PIPING IS SIZED AT 2 PSI DELIVERY WITH MAXIMUM 1 PSI PRESSURE DROP. I. SEE RISER DIAGRAMS ON SHEETS P-601 THROUGH P-605 FOR ALL PIPE SIZING SERVING GUEST ROOMS.www.coffman.com221 N. Wall Street, Suite 500Spokane, WA 99201ph 509.328.299432 MERCHANT STREET, SUITE 208HONOLULU, HI 96813808-352-5299NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.OWNER:THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 99216UNDERFLOORPLUMBING PLANP-100
FSC PROJECT NO. 21012PERMIT SETMAY 30, 2024GL8 MirabeauPoint, LLCTMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-09013/32" = 1'-0"UNDERFLOOR PLUMBING PLANKEY NOTES1PROVIDE MIN. 8' HORIZONTAL PIPE LENGTH ON SUDS STACKSPRIOR TO CONNECTION TO MAIN.2 VERIFY LOCATION WITH ELEVATOR MANUFACTURE'SINSTALLATION INSTRUCTIONS.3 USE TYPE 'K' COPPER FOR PUMPED WASTE. ROUTE BELOWGRADE TO LAUNDRY TROUGH. INSTALL FINAL TERMINATION INLAUNDRY TROUGH PER 13/P-501.4 CONNECT TO POOL DECK DRAIN SYSTEM WITH P-TRAP ANDTRAP PRIMER. MANIFOLD TRAP PRIMER PIPING IN POOL MECHROOM.0'6'12'24'SCALE: 3/32" = 1'-0"Revision ScheduleNumber Description Date2 Addendum26/21/20242PRELIMINARYNOT FOR CONSTRUCTION5/30/2024I.E.
ABCDEFGHJKL.1MNPQ98.1876.1655443.13.1332.12.11.11.122LOBBY121FOOD PREP123EFFICIENCY129EFFICIENCY131EFFICIENCY133DOUBLE QUEEN135KING STUDIO137LANAI137ALANAI135AKING STUDIO ADA-M-T138DOUBLE QUEEN136EFFICIENCY134STAIR 2132KING STUDIO130ELECTRICAL128SALES OFFICE126GM OFFICE125OPEN OFFICE124OWNER'S OFFICE127VESTIBULE122MEETING ROOM120MEETING STORAGE119GUEST STORAGE118WOMEN'S RESTROOM115MEN'S RESTROOM116ELEVATOR LOBBY117ELEV 2113ELEV 1111HOUSEKEEPING OFFICE109AFITNESS114LAUNDRY LOUNGE112EMP RR ADA110AEMPLOYEE ROOM110WATER HEATER & FIRE108STAIR 1106BOH LAUNDRY105LINEN DISCHARGE &SORTING107ELECTRICAL104PUBLIC CORRIDOR100POOL MEP103POOL & SPLASH PAD101POOL RESTROOM102P-4011P-4014P-4021P-4022SH-5L-1WC-2DF-1FD-1WH-1FD-1FD-1FCOS-1S-3EW-14" HWWC-22" W UPWC-2L-1L-1FD-1FD-1FD-1L-1L-1FD-1WC-2WC-2WC-2WC-2FD-1U-1U-1L-1L-14" W UP4" WCO4" WCOGREASE INTERCEPTORWCO1/2" G DN TO DRYER (TYP)4" W1/2" G TO PRE-MANUFACTURED FIREPIT -PROVIDE ISOLATION VALVE (REGULATOR BY VENDOR)1/2" G TO PRE-MANUFACTURED FIREPIT-PROVIDE ISOLATION VALVE (REGULATOR BY VENDOR)1/2" G TO BARBEQUE-PROVIDE ISOLATION VALVE (REGULATOR BY VENDOR)RISER-1RISER-2RISER-4RISER-3RISER-5RISER-6RISER-7RISER-8RISER-9RISER-10RISER-11RISER-12RISER-13RISER-14RISER-15RISER-16RISER-18RISER-17RISER-19RISER-20RISER-22RISER-21RISER-23RISER-25RISER-24RISER-26RISER-27RISER-29RISER-28RISER-30RISER-31L-1111111111111111MGAS METER BY UTILITY3/4" G DN TO DH-011" G DN TO POOL BOILERFD-11 1/4" G1 1/4" G1 1/4" G1" G1/2" G3/4" G1 1/2" G1" G1" G UP TO ERV-012" GOVERFLOW ROOF DRAINDS-11" HW1" HW1" CW1" CW1" HW1" CW4" HW3" CW1 1/2" HW2" CW2" HWFCO2" W UP2" WASTE UP TO CLOTHS WASHER -ROUTE BELOW SANITARY SERVING SINK AND TIE DIRECTLY INTO MAIN BELOW CHASE2" W2" W2" W2" W SERVING SINK ABOVE4" WHB-2COGCOG2222222223/4" HWC2224" W3/4" HWC2.5 GPM2" CW2 1/2" CW3" CW4" CW2" CW2" CW1 1/4" CW TO POOL MAKE-UPWATER SOFTENERSP-40311" HW 140°F3/4" HWC (140° F)3/4" CW1/2" CW2" V2" V1 1/2" CW1/2" HWBF-11 1/4" CW1 1/4" HW1 1/2" CW1 1/4" HWFS-14" W DN22" V3" VBF-12" V1/2" CW3/4" HWC1" HW1 1/4" HWC3" HW3" CW3/4" HWC1" HW1" HWC2 1/2" HW1" HWC2 1/2" HW2 1/2" CW1" HWC2" HW2" CW3/4" HWC1 1/2" HW1 1/2" CW4" W(LOW TEMP)4" CW1 1/4" HWC4" HW4" CW1 1/4" HWC4" HW4" CW1 1/2" HWC3/4" HWC1" HW3/4" HWC3/4" CWWCO2" W3" RD3" ORD3" RD3" ORD3" UP TO RDL/ODL ABOVE4" W4" WMAU-01FD-1HB-1HB-11/2" CW3/4" CW3/4" CWHIGH TEMP 140°F HW DN TO MOP SINK1/2" G TO MAU-1FS-1FS-1COGCOG2" VTD-2HUB DRAIN, SEE DETAIL 122" V2" V2" V2" V2" V2" V2" V2" V2" V22" V22OVERFLOW ROOF DRAIN4" ORD2GENERAL PLUMBING NOTESA. PLUMBING PLANS SHOW GENERAL ROUTING AND ARRANGEMENT OF PIPING. B. CONTRACTOR SHALL COORDINATE ROUTING AND SPACE REQUIREMENTS OF PIPING WITH STRUCTURAL MEMBERS AND ALL OTHER TRADES INCLUDING HVAC, FIRE PROTECTION, ELECTRICAL, AND COMMUNICATIONS/DATA. OFFSET PIPING AROUND DUCTWORK AND OTHER OBSTACLES WHERE REQUIRED.C. ALL PIPING SHALL BE SLEEVED AND SEALED THROUGH ANY STRUCTURE OR CONCRETE. D. DOMESTIC WATER PIPE SIZING SHOWN IS BASED ON TYPE ‘L’COPPER WATER TUBING. WHEN PEX PIPING IS SUBSTITUTED (IF APPROVED FOR USE), THE CONTRACTOR SHALL UPSIZE PIPING ACCORDINGLY SO THE INSIDE DIAMETER OF THE PEX PIPING MATCHES THE INSIDE DIAMETER OF TYPE ‘L’ COPPER PIPING.E. COORDINATE PLUMBING VENT LOCATIONS WITH MECHANICAL. LOCATE PLUMBING VENTS 10'-0" MIN. FROM ANY BUILDING OPENING OR HVAC AIR INTAKE.F. WASTE AND VENT PIPING SHALL BE NO-HUB CAST IRON OR SCHEDULE 40 PVC DWV. EXPOSED WASTE AND VENT PIPING SHALL BE CAST IRON.G. ABOVE GRADE RAIN DRAIN AND OVERFLOW DRAIN PIPING SHALL BE SCHED. 40 PVC DWV. RAIN DRAIN RISERS SHALL BE CAST IRON.H. SLOPE ALL ABOVE GRADE RAIN DRAIN AND OVERFLOW DRAIN PIPING AT 1/4" PER FOOT, MIN. UNO.I. PROVIDE AND INSTALL CLEANOUTS AT THE BASE OF ALL ROOF DRAINS.J. CONDENSATE DRAIN PIPING SHALL BE TYPE 'L' OR 'M' COPPER. SLOPE ALL CONDENSATE DRAIN PIPING AT 1/8" PER FOOT, MIN.K. SEE ARCHITECTURAL FOR FIXTURE MOUNTING HEIGHTS.L. SEE PLUMBING FIXTURE SCHEDULE FOR PIPE SIZING OF BRANCH CLOSEST TO FIXTURE. TRAP ARMS MAY BE SIZED THE SAME AS FIXTURE OUTLET. UNDERGROUND PIPING SHALL BE NO LESS THAN 2".M. TRAP PRIMER PIPING NOT SHOWN FOR CLARITY. SEE FLOOR PLANS FOR WATER AND DRAIN LOCATIONS, AND PLUMBING FIXTURE SCHEDULE FOR PRIMER REQUIREMENTS.N. INSTALL WATER HAMMER ARRESTORS IN CONFORMANCE WITH MANUFACTURER'S INSTRUCTIONS AND GUIDELINES.O. PROVIDE ACCESS DOORS TO ALL CONCEALED VALVES AND WATER HAMMER ARRESTORS.P. PROVIDE AND INSTALL CLEANOUTS AT ALL SINKS AND URINALS.Q. PROVIDE ISOLATION VALVES AT ACCESSIBLE LOCATIONS FOR ALL WATER PIPING BRANCHES, INCLUDING ALL HOSE BIBBS AND RESTROOMSR. LOCATE DOWNSPOUT NOZZLES AT 18" AFF.S. REFER TO ARCHITECTURAL FOR VTR FLASHING DETAILS. FLASHING TO BE COMPATIBLE WITH ROOFING SYSTEM.T. NO PIPING SHALL PENETRATE THE SHEAR WALL TOP OR BOTTOM PLATE. PIPING TO FLOORS ABOVE OR BELOW SHALL USE DESIGNATED CHASES OR GO THROUGH NON-SHEAR WALLS.U. PROVIDE A MANUAL CIRCUIT SETTER ON EACH HWC RISER BEFORE IT CONNECTS TO THE MAIN HWC LINE ON LEVEL 1. SET TO 0.75 GPM. V. SEE RISER DIAGRAMS ON SHEETS P-601 THROUGH P-605 FOR ALL PIPE SIZING SERVING GUEST ROOMS.FLOOR4" WPIPING BY POOL CONTRACTOR72" MAX12" MINP-TRAP2" V4" W6" AIR GAP2'-0" MIN.12" MIN2" MAX.1/2" WIRE MECH STRAINER SECURED IN HUB DRAINWYE AND 1/8" BEND COMBOwww.coffman.com221 N. Wall Street, Suite 500Spokane, WA 99201ph 509.328.299432 MERCHANT STREET, SUITE 208HONOLULU, HI 96813808-352-5299NOTE: CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT JOB BEFORE PROCEEDING WITH WORK.OWNER:THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 99216GROUND FLOORPLUMBING PLANP-101FSC PROJECT NO. 21012PERMIT SETMAY 30, 2024GL8 MirabeauPoint, LLCTMK:PID: 45101.040110909 E. Pierce LaneSpokane, WA 99206(509) 919-09013/32" = 1'-0"GROUND FLOOR PLUMBING PLANKEY NOTES12" W UP SERVING FIXTURE IN ROOM ABOVE, 2" V DN IN WALLSERVING FIXTURE BELOW.2 3/4" HWC FROM 4TH FLOOR. SEE DOMESTIC WATER RISERDIAGRAM. LOCATE CIRCUIT SETTER IN ACCESSIBLE LOCATION INHALLWAY.0'6'12'24'SCALE: 3/32" = 1'-0"Revision ScheduleNumber Description Date2 Addendum26/21/2024NTS2BACKWASH DRAIN2 PRELIMINARYNOT FOR CONSTRUCTION5/30/2024
A
A
B
B
C
C D
C.1 E
E
F
F
G
G
H
H
J
J
K
K
L.1
L.1
M
M
N
N
P
P
Q
Q
99
8.1
88
77
6.1
66
5
44
3.13.1
33
2.12.1
1.1
2 2
KING 1-BEDROOM ENLARGED
201
KING 1-BEDROOM
202
KING STUDIO
204
EFFICIENCY ENLARGED
203
EFFICIENCY
205
STAIR 1
206
EFFICIENCY
208
ENGINEERING OFFICE &
STORAGE
207
DOUBLE QUEEN
210
DOUBLE QUEEN ENLARGED
212
KING STUDIO
214 KING STUDIO
216
KING STUDIO
218
KING STUDIO
220
DOUBLE QUEEN
222 DOUBLE QUEEN
224
KING STUDIO
226
EFFICIENCY
228
KING STUDIO
230
STAIR 2
232
EFFICIENCY
234 DOUBLE QUEEN
236
DOUBLE QUEEN
235
EFFICIENCY
233
EFFICIENCY
231
EFFICIENCY
229EFFICIENCY
227
KING STUDIO
225
KING STUDIO
223KING STUDIO
221
KING STUDIO
219ELEVATOR LOBBY
217
ELEV 1
111
ELEV 2
113
PBX/MDF
207A
P-401
3
P-401
5
P-402
4
P-402
5
1
1 11 1
1
RISER-1
RISER-2
RISER-4
RISER-3
RISER-5
RISER-6
RISER-7
RISER-8
RISER-9
RISER-11 RISER-12 RISER-13
RISER-14
RISER-15 RISER-16
RISER-18RISER-17
RISER-19 RISER-20
RISER-22RISER-21
RISER-23
RISER-25RISER-24
RISER-26 RISER-27
RISER-29RISER-28
RISER-30
RISER-31
RISER-10
RD-1OD-1 RD-1OD-1
KING STUDIO ADA-M-T
238
KING STUDIO
237
www.coffman.com
221 N. Wall Street, Suite 500
Spokane, WA 99201
ph 509.328.2994
32 MERCHANT STREET, SUITE 208
HONOLULU, HI 96813
808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND
VERIFY ALL DIMENSIONS AT JOB BEFORE
PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER
MY SUPERVISION AND CONSTRUCTION OF THIS
PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 992162ND FLOOR PLUMBING
PLAN
P-102
FSC PROJECT NO. 21012
PERMIT SET
MAY 30, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce Lane
Spokane, WA 99206
(509) 919-0901
3/32" = 1'-0"
2ND FLOOR PLUMBING PLAN
KEY NOTES
1 CONNECT BALCONY DRAIN TO PTAC CONDENSATE RISER.
0'6'12'24'
SCALE: 3/32" = 1'-0"
Revision Schedule
Number Description Date
5/30/2024
A
A
B
B
C
C D
C.1 E
E
F
F
G
G
H
H
J
J
K
K
L.1
L.1
M
M
N
N
P
P
Q
Q
99
8.1
88
77
6.1
66
55
44
3.13.1
33
2.12.1
1.11.1
2 2
KING 1-BEDROOM ADA-M-T
301
KING 1-BEDROOM ADA-M-T
301
KING 1-BEDROOM
302
KING STUDIO
304
EFFICIENCY ENLARGED
303
EFFICIENCY
305
STAIR 1
306
EFFICIENCY
307
EFFICIENCY
308
DOUBLE QUEEN
310
LINENES & HOUSEKEEPING
309
ELEV 1
111
ELEV 2
113
ELEVATOR LOBBY
317
DOUBLE QUEEN ENLARGED
312
KING STUDIO
314
KING STUDIO
316 KING STUDIO
318
KING STUDIO
320
DOUBLE QUEEN
322
DOUBLE QUEEN
324
KING STUDIO
326
EFFICIENCY
328
KING STUDIO
330
STAIR 2
332
EFFICIENCY
334
DOUBLE QUEEN
336
KING STUDIO ADA-M-RI
338
KING STUDIO
337DOUBLE QUEEN
335
EFFICIENCY
333
EFFICIENCY
331
EFFICIENCY
329
EFFICIENCY
327
KING STUDIO
325
KING STUDIO
323
KING STUDIO
321
KING STUDIO
319
P-401
2
P-402
6
1
1
1 1 1 1
1
1
RISER-1
RISER-2
RISER-4
RISER-3
RISER-5
RISER-6
RISER-8
RISER-9
RISER-11 RISER-12 RISER-13
RISER-14
RISER-15 RISER-16
RISER-18RISER-17
RISER-19 RISER-20
RISER-22RISER-21
RISER-23
RISER-25RISER-24
RISER-26 RISER-27
RISER-29RISER-28
RISER-30
RISER-31
www.coffman.com
221 N. Wall Street, Suite 500
Spokane, WA 99201
ph 509.328.2994
32 MERCHANT STREET, SUITE 208
HONOLULU, HI 96813
808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND
VERIFY ALL DIMENSIONS AT JOB BEFORE
PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER
MY SUPERVISION AND CONSTRUCTION OF THIS
PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 992163RD FLOOR PLUMBING
PLAN
P-103
FSC PROJECT NO. 21012
PERMIT SET
MAY 30, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce Lane
Spokane, WA 99206
(509) 919-0901
3/32" = 1'-0"
3RD FLOOR PLUMBING PLAN
KEY NOTES
1 CONNECT BALCONY DRAIN TO PTAC CONDENSATE RISER.
0'6'12'24'
SCALE: 3/32" = 1'-0"
Revision Schedule
Number Description Date
5/30/2024
A
A
B
B
C
C D
C.1 E
E
F
F
G
G
H
H
J
J
K
K
L.1
L.1
M
M
N
N
P
P
Q
Q
99
8.1
88
77
6.1
66
55
44
3.13.1
33
2.12.1
1.11.1
2 2
KING STUDIO
437
DOUBLE QUEEN
435EFFICIENCY
433
EFFICIENCY
431
EFFICIENCY
429KING STUDIO
425
KING STUDIO
423
KING STUDIO
421KING STUDIO
419
LINENES & HOUSEKEEPING
409
ELEV 1
111
ELEV 2
113
EFFICIENCY
407
EFFICIENCY
405
EFFICIENCY ADA-M-RI
403
KING 1-BEDROOM ENLARGED
401KING 1-BEDROOM
402
KING STUDIO
404
STAIR 1
406
EFFICIENCY
408
DOUBLE QUEEN
410
DOUBLE QUEEN ENLARGED
412
KING STUDIO
414
KING STUDIO
416 KING STUDIO
418
KING STUDIO
420
DOUBLE QUEEN
422
DOUBLE QUEEN
424
KING STUDIO
426 EFFICIENCY
428
KING STUDIO
430
STAIR 2
432
DOUBLE QUEEN
436
KING STUDIO ENLARGED
438
ELEVATOR LOBBY
417
P-401
6
1
1
1 1 1 1
1
1
2
2
2
RISER-1
RISER-2
RISER-4
RISER-3
RISER-5
RISER-6
RISER-7
RISER-8
RISER-9
RISER-10
RISER-11
RISER-12 RISER-13
RISER-14
RISER-15 RISER-16
RISER-18RISER-17
RISER-19 RISER-20
RISER-22RISER-21
RISER-23
RISER-25RISER-24
RISER-26 RISER-27
RISER-29
RISER-28
RISER-30
RISER-31
2
2 2
2 2
2 2
2 2
2 2
2 2
2 2
2
2
2
2
2
22
2
2
22
22
2
2
22
22
22
22
22
2
2
2
2
2
2
2
2
2
22
2
HWC DN TO
GROUND FLOOR
5" ORD
5" RD
8" RAD UP
www.coffman.com
221 N. Wall Street, Suite 500
Spokane, WA 99201
ph 509.328.2994
32 MERCHANT STREET, SUITE 208
HONOLULU, HI 96813
808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND
VERIFY ALL DIMENSIONS AT JOB BEFORE
PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER
MY SUPERVISION AND CONSTRUCTION OF THIS
PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 992164TH FLOOR PLUMBING
PLAN
P-104
FSC PROJECT NO. 21012
PERMIT SET
MAY 30, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce Lane
Spokane, WA 99206
(509) 919-0901
3/32" = 1'-0"
4TH FLOOR PLUMBING PLAN
KEY NOTES
1 CONNECT BALCONY DRAIN TO PTAC CONDENSATE RISER.
2 2" W UP SERVING FIXTURE IN ROOM ABOVE, 2" V DN IN WALL
SERVING FIXTURE BELOW.
0'6'12'24'
SCALE: 3/32" = 1'-0"
Revision Schedule
Number Description Date
5/30/2024
A
A
B
B
C
C D
C.1 E
E
F
F
G
G
H
H
J
J
K
K
L.1
L.1
M
M
N
N
P
P
Q
Q
99
8.1
88
77
6.1
66
55
44
3.13.1
33
2.1
1.11.1
2
1
1
1 1 1 1
1
1
RISER-1
RISER-2
RISER-4
RISER-3
RISER-5
RISER-6
RISER-7
RISER-8
RISER-9
RISER-10
RISER-11 RISER-12 RISER-13
RISER-14
RISER-15 RISER-16
RISER-18RISER-17
RISER-19 RISER-20
RISER-22
RISER-21
RISER-23
RISER-25RISER-24
RISER-26 RISER-27
RISER-29
RISER-28
RISER-30
RISER-31
3" RD
3" ORD
4" RD
4" ORD
3" RD
3" ORD5" RD 5" ORD
4" RD
4" ORD4" RD4" ORD4" ORD4" RD4" RD4" ORD3" RD3" ORD5" RD5" ORD1/8" SLOPE1/8" SLOPE1/8" SLOPE
1/8" SLOPE
1/8" SLOPE
1/8" SLOPE
1/8" SLOPE
1/8" SLOPE
4" ORD DN
IN CHASE
4" RD DN
IN CHASE
DOUBLE QUEEN
510
DOUBLE QUEEN ADA-M-T
512
KING STUDIO
514
KING STUDIO
516
KING STUDIO
518
KING STUDIO
520
DOUBLE QUEEN
522
DOUBLE QUEEN
524
KING STUDIO
526
EFFICIENCY
528
KING STUDIO
530 EFFICIENCY
534
DOUBLE QUEEN
536
KING STUDIO ENLARGED
538
KING STUDIO
537
DOUBLE QUEEN
535
EFFICIENCY
533
EFFICIENCY
531
EFFICIENCY
529
EFFICIENCY
527
KING STUDIO
525
KING STUDIO
523
KING STUDIO
521
KING STUDIO
519
ELEVATOR LOBBY
517
LINENES & HOUSEKEEPING
509
EFFICIENCY
507
EFFICIENCY
505
EFFICIENCY
508
KING STUDIO
504
EFFICIENCY ADA-M-T
503
KING 1-BEDROOM ENLARGED
501KING 1-BEDROOM
502
GUEST CORRIDOR
515
P-403
2
www.coffman.com
221 N. Wall Street, Suite 500
Spokane, WA 99201
ph 509.328.2994
32 MERCHANT STREET, SUITE 208
HONOLULU, HI 96813
808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND
VERIFY ALL DIMENSIONS AT JOB BEFORE
PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER
MY SUPERVISION AND CONSTRUCTION OF THIS
PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 992165TH FLOOR PLUMBING
PLAN
P-105
FSC PROJECT NO. 21012
PERMIT SET
MAY 30, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce Lane
Spokane, WA 99206
(509) 919-0901
3/32" = 1'-0"
5TH FLOOR PLUMBING PLAN
KEY NOTES
1 CONNECT BALCONY DRAIN TO PTAC CONDENSATE RISER.
0'6'12'24'
SCALE: 3/32" = 1'-0"
Revision Schedule
Number Description Date
5/30/2024
GENERAL NOTES
A. LOCATE PLUMBING VENTS AND EXHAUST FANS/STACKS 25'-0" MIN.
FROM HVAC AIR INTAKES, AS SHOWN WITH DASHED CIRCLES ON
PLAN.
B. LOCATE ALL SERVICABLE EQUIPMENT A MINIMUM OF 10'-0" AWAY
FROM BUILDING EDGE.
A B C DC.1
E F G H J K L.1 M N P Q
9
8.1
8
7
6.1
6
5
4
3.1
3
2.1
1.1
2
CU-05
ERV-01
CU-02
3" V
3" V
3" V
3" V
3" V
3" V
3" V
3" V
3" V
3" V
3" V
3" V
3" V
3" V
3" V
3" V
3" V
3" V
3" V
3" V
CU-03
RD-1
OD-1OD-1
RD-1OD-1
RD-1
OD-1
RD-1
OD-1
RD-1
OD-1
RD-1
OD-1
RD-1OD-1RD-1OD-1RD-1OD-1RD-1OD-1
8" RAD
CU-04
1" G
RD-1
3" V
RL/RS DN
RL/RS DN
1" G
www.coffman.com
221 N. Wall Street, Suite 500
Spokane, WA 99201
ph 509.328.2994
32 MERCHANT STREET, SUITE 208
HONOLULU, HI 96813
808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND
VERIFY ALL DIMENSIONS AT JOB BEFORE
PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER
MY SUPERVISION AND CONSTRUCTION OF THIS
PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 99216PLUMBING ROOF PLAN
P-106
FSC PROJECT NO. 21012
PERMIT SET
MAY 30, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce Lane
Spokane, WA 99206
(509) 919-0901
0'6'12'24'
SCALE: 3/32" = 1'-0"
3/32" = 1'-0"
PLUMBING ROOF PLAN
Revision Schedule
Number Description Date
5/30/2024
D D D D
WWWW
D D D D
WWWW
A B C DC.1
E F G H J K L.1 M N P Q
9
8.1
8
7
6.1
6
5
4
3.1
3
2.1
1.1
2
FCU-215
FCU-216
FCU-213
FCU-211
FCU-212
BCU-02
3/4" D
3/4" D
3/4" D
3/4" D
3/4" D
3/4" D
3/4" D
3/4" D
RL/RS UP
RL/RS
UP
AHU-01
RL/RS UP
3/4" D
RISER-10
STACK-33
STACK-1
STACK-2
STACK-3
STACK-4
STACK-5
STACK-6 STACK-7 STACK-8 STACK-9
STACK-10 STACK-11 STACK-12 STACK-13
STACK-14
STACK-15
STACK-16
STACK-17
STACK-18
STACK-19
STACK-20
STACK-21
STACK-22STACK-23
STACK-24STACK-25
STACK-26
STACK-27
STACK-28
STACK-29
STACK-30
STACK-31
STACK-32
1
2
1
1
1
1
KING STUDIO
137
KING STUDIO ADA-M-T
138
DOUBLE QUEEN
136
EFFICIENCY
134
STAIR 2
132
KING STUDIO
130OWNER'S OFFICE
127
SALES OFFICE
126
GM OFFICE
125
OPEN OFFICE
124
FOOD PREP
123
EFFICIENCY
129
EFFICIENCY
131
EFFICIENCY
133
DOUBLE QUEEN
135
LOBBY
121
MEETING ROOM
120
ELEVATOR LOBBY
117ELEV 1
111
ELEV 2
113LINEN STORAGE
109
BOH LAUNDRY
105
LINEN DISCHARGE &
SORTING
107
LAUNDRY LOUNGE
112
GUEST STORAGE
118
MEN'S RESTROOM
116
WOMEN'S RESTROOM
115
MEETING STORAGE
119
FITNESS
114
WATER HEATER & FIRE
108
STAIR 1
106
ELECTRICAL
104VESTIBULE
100A
POOL & SPLASH PAD
101
POOL RESTROOM
102
POOL MEP
103
MAU-01
1-1/2" D
1-1/2" DRAIN DOWN
IN WALL TO FLOOR
SINK
GENERAL PIPING NOTES
A. PLUMBING PLANS SHOW GENERAL ROUTING AND ARRANGEMENT
OF PIPING.
B. CONTRACTOR SHALL COORDINATE ROUTING AND SPACE
REQUIREMENTS OF PIPING WITH STRUCTURAL MEMBERS AND ALL
OTHER TRADES INCLUDING HVAC, FIRE PROTECTION,
ELECTRICAL, AND COMMUNICATIONS/DATA. OFFSET PIPING
AROUND DUCTWORK AND OTHER OBSTACLES WHERE REQUIRED.
C. INDOOR CONDENSATE DRAIN PIPING SHALL BE TYPE 'L' OR 'M'
COPPER OR SCHED. 40 PVC. SLOPE ALL CONDENSATE DRAIN
PIPING AT 1/8" PER FOOT, MIN.
D. ALL FAN COILS SHALL HAVE A BUILT-IN CONDENSATE PUMP.
E. TERMINATE DRAIN STACKS AT EXTERIOR WALL WITH DOWNWARD
FACING ELBOW LOCATED 18" AFF. ALL EXPOSED EXTERIOR PIPING
AND FITTINGS SHALL BE STEEL PAINTED TO MATCH EXTERIOR.
PROVIDE ESCUTCHEON TO TRIM PIPING AT FINISHED EXTERIOR. www.coffman.com
221 N. Wall Street, Suite 500
Spokane, WA 99201
ph 509.328.2994
32 MERCHANT STREET, SUITE 208
HONOLULU, HI 96813
808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND
VERIFY ALL DIMENSIONS AT JOB BEFORE
PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER
MY SUPERVISION AND CONSTRUCTION OF THIS
PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 99216GROUND FLOOR
REFRIGERANT AND
CONDENSATE PIPING
PLAN
P-111
FSC PROJECT NO. 21012
PERMIT SET
MAY 30, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce Lane
Spokane, WA 99206
(509) 919-0901
3/32" = 1'-0"
GROUND FLOOR REFRIGERANT AND CONDENSATE PIPING PLAN
0'6'12'24'
SCALE: 3/32" = 1'-0"
KEY NOTES
1 ROUTE CONDENSATE LINE DOWN WALL AND CONNECT TO SINK
TAIL PIECE.
2 ROUTE RL/RS PIPING FROM BRANCH CONTROLLER (BC) TO FCU.
Revision Schedule
Number Description Date
5/30/2024
W/DW/DW/DW/DGENERAL PIPING NOTES
A. PLUMBING PLANS SHOW GENERAL ROUTING AND ARRANGEMENT
OF PIPING.
B. CONTRACTOR SHALL COORDINATE ROUTING AND SPACE
REQUIREMENTS OF PIPING WITH STRUCTURAL MEMBERS AND ALL
OTHER TRADES INCLUDING HVAC, FIRE PROTECTION,
ELECTRICAL, AND COMMUNICATIONS/DATA. OFFSET PIPING
AROUND DUCTWORK AND OTHER OBSTACLES WHERE REQUIRED.
C. INDOOR CONDENSATE DRAIN PIPING SHALL BE TYPE 'L' OR 'M'
COPPER OR SCHED. 40 PVC. SLOPE ALL CONDENSATE DRAIN
PIPING AT 1/8" PER FOOT, MIN.
D. ALL FAN COILS SHALL HAVE A BUILT-IN CONDENSATE PUMP.
E. TERMINATE DRAIN STACKS AT EXTERIOR WALL WITH DOWNWARD
FACING ELBOW LOCATED 18" AFF. ALL EXPOSED EXTERIOR PIPING
AND FITTINGS SHALL BE STEEL PAINTED TO MATCH EXTERIOR.
PROVIDE ESCUTCHEON TO TRIM PIPING AT FINISHED EXTERIOR.
A B C DC.1
E F G H J K L.1 M N P Q
9
8.1
8
7
6.1
6
5
4
3.1
3
2.1
1.1
2
3/4" DRAIN
3/4" DRAIN
3/4" DRAIN
3/4" DRAIN
3/4" DRAIN
3/8" RL
5/8" RS
3/4" DRAIN 3/4" DRAIN
STACK-33
STACK-1
STACK-2
STACK-3
STACK-4
STACK-5
STACK-6 STACK-7 STACK-8 STACK-9
STACK-10 STACK-11 STACK-12 STACK-13
STACK-14
STACK-15
STACK-16
STACK-17
STACK-18
STACK-19
STACK-20
STACK-21
STACK-22STACK-23
STACK-24STACK-25STACK-26
STACK-27
STACK-28
STACK-29
STACK-30
STACK-31
STACK-32
1
1
1
1
1
FCU-321
FCU-324FCU-323
FCU-421
FCU-322
FCU-325 FCU-326
1 1
KING STUDIO
237
KING STUDIO ADA-M-T
238
DOUBLE QUEEN
236
EFFICIENCY
234
STAIR 2
232
KING STUDIO
230
EFFICIENCY
228
KING STUDIO
226DOUBLE QUEEN
224
DOUBLE QUEEN
222
KING STUDIO
220
KING STUDIO
218
KING STUDIO
216
KING STUDIO
214
KING STUDIO
219
KING STUDIO
221
KING STUDIO
223
KING STUDIO
225
EFFICIENCY
227
EFFICIENCY
229
EFFICIENCY
231
EFFICIENCY
233
DOUBLE QUEEN
235
GUEST CORRIDOR
215
DOUBLE QUEEN ENLARGED
212
DOUBLE QUEEN
210
LINENES & HOUSEKEEPING
209
EFFICIENCY
208
EFFICIENCY
205
ENGINEERING OFFICE &
STORAGE
207
STAIR 1
206
KING STUDIO
204
EFFICIENCY ENLARGED
203
KING 1-BEDROOM ENLARGED
201KING 1-BEDROOM
202
RL/RS UP/DN TYP
www.coffman.com
221 N. Wall Street, Suite 500
Spokane, WA 99201
ph 509.328.2994
32 MERCHANT STREET, SUITE 208
HONOLULU, HI 96813
808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND
VERIFY ALL DIMENSIONS AT JOB BEFORE
PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER
MY SUPERVISION AND CONSTRUCTION OF THIS
PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 992162ND FLOOR
REFRIGERANT AND
CONDENSATE PIPING
PLAN
P-112
FSC PROJECT NO. 21012
PERMIT SET
MAY 30, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce Lane
Spokane, WA 99206
(509) 919-0901
0'6'12'24'
SCALE: 3/32" = 1'-0"
KEY NOTES
1 ROUTE CONDENSATE LINE DOWN WALL AND CONNECT TO SINK
TAIL PIECE.
3/32" = 1'-0"
2ND FLOOR REFRIGERANT AND CONDENSATE PIPING
Revision Schedule
Number Description Date
5/30/2024
W/DWDMicrowaveW/DWDMicrowaveA
A
B
B
C
C D
C.1 E
E
F
F
G
G
H
H
J
J
K
K
L.1
L.1
M
M
N
N
P
P
Q
Q
99
8.1
88
77
6.1
66
55
44
3.13.1
33
2.12.1
1.11.1
2 2
3/4" DRAIN
3/4" DRAIN
3/4" DRAIN
1/4" RL
1/2" RS
3/4" DRAIN 3/4" DRAIN
BCU-01
STACK-33
STACK-1
STACK-2
STACK-3
STACK-4
STACK-5
STACK-6 STACK-7 STACK-8 STACK-9
STACK-10 STACK-11 STACK-12 STACK-13
STACK-14
STACK-15
STACK-16
STACK-17
STACK-18
STACK-19
STACK-20
STACK-21
STACK-22STACK-23
STACK-24STACK-25STACK-26
STACK-27
STACK-28
STACK-29
STACK-30
STACK-31
STACK-32
1
2
1
1
1 1
FCU-335FCU-334
FCU-333FCU-332
FCU-331
KING STUDIO
337
DOUBLE QUEEN
335
EFFICIENCY
333
EFFICIENCY
331
EFFICIENCY
329
EFFICIENCY
327
KING STUDIO
325
KING STUDIO
323
KING STUDIO
321
KING STUDIO
319
KING STUDIO
320 DOUBLE QUEEN
322
DOUBLE QUEEN
324
KING STUDIO
326
EFFICIENCY
328
KING STUDIO
330 EFFICIENCY
334
DOUBLE QUEEN
336
KING STUDIO ADA-M-RI
338
GUEST CORRIDOR
315
STAIR 2
332
KING STUDIO
318
KING STUDIO
316
KING STUDIO
314
DOUBLE QUEEN ENLARGED
312
DOUBLE QUEEN
310
LINENES & HOUSEKEEPING
309
EFFICIENCY
308
EFFICIENCY
307
EFFICIENCY
305
EFFICIENCY ENLARGED
303
KING 1-BEDROOM ADA-M-T
301KING 1-BEDROOM
302
KING STUDIO
304
STAIR 1
306
ELEVATOR LOBBY
317
ELEV 2
113
ELEV 1
111
RL/RS
UP/DN
TYP
GENERAL PIPING NOTES
A. PLUMBING PLANS SHOW GENERAL ROUTING AND ARRANGEMENT
OF PIPING.
B. CONTRACTOR SHALL COORDINATE ROUTING AND SPACE
REQUIREMENTS OF PIPING WITH STRUCTURAL MEMBERS AND ALL
OTHER TRADES INCLUDING HVAC, FIRE PROTECTION,
ELECTRICAL, AND COMMUNICATIONS/DATA. OFFSET PIPING
AROUND DUCTWORK AND OTHER OBSTACLES WHERE REQUIRED.
C. INDOOR CONDENSATE DRAIN PIPING SHALL BE TYPE 'L' OR 'M'
COPPER OR SCHED. 40 PVC. SLOPE ALL CONDENSATE DRAIN
PIPING AT 1/8" PER FOOT, MIN.
D. ALL FAN COILS SHALL HAVE A BUILT-IN CONDENSATE PUMP.
E. TERMINATE DRAIN STACKS AT EXTERIOR WALL WITH DOWNWARD
FACING ELBOW LOCATED 18" AFF. ALL EXPOSED EXTERIOR PIPING
AND FITTINGS SHALL BE STEEL PAINTED TO MATCH EXTERIOR.
PROVIDE ESCUTCHEON TO TRIM PIPING AT FINISHED EXTERIOR. www.coffman.com
221 N. Wall Street, Suite 500
Spokane, WA 99201
ph 509.328.2994
32 MERCHANT STREET, SUITE 208
HONOLULU, HI 96813
808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND
VERIFY ALL DIMENSIONS AT JOB BEFORE
PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER
MY SUPERVISION AND CONSTRUCTION OF THIS
PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 992163RD FLOOR
REFRIGERANT AND
CONDENSATE PIPING
PLAN
P-113
FSC PROJECT NO. 21012
PERMIT SET
MAY 30, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce Lane
Spokane, WA 99206
(509) 919-0901
3/32" = 1'-0"
3RD FLOOR REFRIGERANT AND CONDENSATE PIPING PLAN
0'6'12'24'
SCALE: 3/32" = 1'-0"
KEY NOTES
1 ROUTE CONDENSATE LINE DOWN WALL AND CONNECT TO SINK
TAIL PIECE.
2 ROUTE RL/RS PIPING FROM BRANCH CONTROLLER (BC) TO FCU.
Revision Schedule
Number Description Date
5/30/2024
W/DW/DW/DW/DA
A
B
B
C
C D
C.1 E
E
F
F
G
G
H
H
J
J
K
K
L.1
L.1
M
M
N
N
P
P
Q
Q
99
8.1
88
77
6.1
66
55
44
3.13.1
33
2.12.1
1.11.1
2 2
3/4" DRAIN
3/4" DRAIN
3/4" DRAIN
3/4" DRAIN
3/4" DRAIN
STACK-33
STACK-1
STACK-2
STACK-3
STACK-4
STACK-5
STACK-6 STACK-7 STACK-8 STACK-9
STACK-10 STACK-11 STACK-12 STACK-13
STACK-14
STACK-15
STACK-16
STACK-17
STACK-18
STACK-19
STACK-20
STACK-21
STACK-22STACK-23
STACK-24STACK-25STACK-26
STACK-27
STACK-28
STACK-29
STACK-30
STACK-31
STACK-32
1
FCU-345FCU-344
FCU-342 FCU-343
FCU-341
1
1
1 1
KING STUDIO
437
KING STUDIO ENLARGED
438DOUBLE QUEEN
436
DOUBLE QUEEN
435
EFFICIENCY
433
EFFICIENCY
431
EFFICIENCY
429
EFFICIENCY
427
KING STUDIO
425
KING STUDIO
423
KING STUDIO
421
KING STUDIO
419
KING STUDIO
420 DOUBLE QUEEN
422
DOUBLE QUEEN
424
KING STUDIO
426
EFFICIENCY
428
KING STUDIO
430 STAIR 2
432
EFFICIENCY
434
GUEST CORRIDOR
415
KING STUDIO
418
KING STUDIO
416
KING STUDIO
414
DOUBLE QUEEN ENLARGED
412
DOUBLE QUEEN
410
LINENES & HOUSEKEEPING
409
ELEVATOR LOBBY
417ELEV 1
111
ELEV 2
113
EFFICIENCY
407
EFFICIENCY
405
EFFICIENCY ADA-M-RI
403
KING 1-BEDROOM ENLARGED
401
KING 1-BEDROOM
402
KING STUDIO
404
EFFICIENCY
408 RL/RS
UP/DN
TYP
2
GENERAL PIPING NOTES
A. PLUMBING PLANS SHOW GENERAL ROUTING AND ARRANGEMENT
OF PIPING.
B. CONTRACTOR SHALL COORDINATE ROUTING AND SPACE
REQUIREMENTS OF PIPING WITH STRUCTURAL MEMBERS AND ALL
OTHER TRADES INCLUDING HVAC, FIRE PROTECTION,
ELECTRICAL, AND COMMUNICATIONS/DATA. OFFSET PIPING
AROUND DUCTWORK AND OTHER OBSTACLES WHERE REQUIRED.
C. INDOOR CONDENSATE DRAIN PIPING SHALL BE TYPE 'L' OR 'M'
COPPER OR SCHED. 40 PVC. SLOPE ALL CONDENSATE DRAIN
PIPING AT 1/8" PER FOOT, MIN.
D. ALL FAN COILS SHALL HAVE A BUILT-IN CONDENSATE PUMP.
E. TERMINATE DRAIN STACKS AT EXTERIOR WALL WITH DOWNWARD
FACING ELBOW LOCATED 18" AFF. ALL EXPOSED EXTERIOR PIPING
AND FITTINGS SHALL BE STEEL PAINTED TO MATCH EXTERIOR.
PROVIDE ESCUTCHEON TO TRIM PIPING AT FINISHED EXTERIOR. www.coffman.com
221 N. Wall Street, Suite 500
Spokane, WA 99201
ph 509.328.2994
32 MERCHANT STREET, SUITE 208
HONOLULU, HI 96813
808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND
VERIFY ALL DIMENSIONS AT JOB BEFORE
PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER
MY SUPERVISION AND CONSTRUCTION OF THIS
PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 992164TH FLOOR
REFRIGERANT AND
CONDENSATE PIPING
PLAN
P-114
FSC PROJECT NO. 21012
PERMIT SET
MAY 30, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce Lane
Spokane, WA 99206
(509) 919-0901
3/32" = 1'-0"
4TH FLOOR REFRIGERANT AND CONDENSATE PIPING PLAN
0'6'12'24'
SCALE: 3/32" = 1'-0"
KEY NOTES
1 ROUTE CONDENSATE LINE DOWN WALL AND CONNECT TO SINK
TAIL PIECE.
2 ROUTE RL/RS PIPING FROM BRANCH CONTROLLER (BC) TO FCU.
Revision Schedule
Number Description Date
5/30/2024
W/DW/DW/DW/DA
A
B
B
C
C D
C.1 E
E
F
F
G
G
H
H
J
J
K
K
L.1
L.1
M
M
N
N
P
P
Q
Q
99
8.1
88
77
6.1
66
55
44
3.13.1
33
2.1
1.11.1
2
3/4" DRAIN
RL/RS UP TYP.
3/4" DRAIN
3/4" DRAIN
3/4" DRAIN 3/4" DRAIN
STACK-33
STACK-1
STACK-2
STACK-3
STACK-4
STACK-5
STACK-6 STACK-7 STACK-8 STACK-9
STACK-10 STACK-11 STACK-12 STACK-13
STACK-14
STACK-15
STACK-16
STACK-17
STACK-18
STACK-19
STACK-20
STACK-21
STACK-22STACK-23
STACK-24STACK-25STACK-26
STACK-27
STACK-28
STACK-29
STACK-30
STACK-31
STACK-32
KING STUDIO
537
KING STUDIO ENLARGED
538
DOUBLE QUEEN
536
EFFICIENCY
534
DOUBLE QUEEN
535
EFFICIENCY
533
EFFICIENCY
531
EFFICIENCY
529
EFFICIENCY
527
KING STUDIO
525
KING STUDIO
523
KING STUDIO
521
KING STUDIO
519
KING STUDIO
520
DOUBLE QUEEN
522 DOUBLE QUEEN
524
KING STUDIO
526
GUEST CORRIDOR
515
KING STUDIO
518
KING STUDIO
516
KING STUDIO
514
DOUBLE QUEEN ADA-M-T
512
LINENES & HOUSEKEEPING
509
DOUBLE QUEEN
510
EFFICIENCY
508 EFFICIENCY
507
ELEVATOR LOBBY
517
STAIR 1
506
EFFICIENCY
505
EFFICIENCY ADA-M-T
503
KING STUDIO
504
KING 1-BEDROOM
502
CONNECTING CORRIDOR
500
KING 1-BEDROOM ENLARGED
501
EFFICIENCY
528
KING STUDIO
530
STAIR 2
532
FCU-351
1
1
1
11
FCU-355FCU-354
FCU-352 FCU-353
2
GENERAL PIPING NOTES
A. PLUMBING PLANS SHOW GENERAL ROUTING AND ARRANGEMENT
OF PIPING.
B. CONTRACTOR SHALL COORDINATE ROUTING AND SPACE
REQUIREMENTS OF PIPING WITH STRUCTURAL MEMBERS AND ALL
OTHER TRADES INCLUDING HVAC, FIRE PROTECTION,
ELECTRICAL, AND COMMUNICATIONS/DATA. OFFSET PIPING
AROUND DUCTWORK AND OTHER OBSTACLES WHERE REQUIRED.
C. INDOOR CONDENSATE DRAIN PIPING SHALL BE TYPE 'L' OR 'M'
COPPER OR SCHED. 40 PVC. SLOPE ALL CONDENSATE DRAIN
PIPING AT 1/8" PER FOOT, MIN.
D. ALL FAN COILS SHALL HAVE A BUILT-IN CONDENSATE PUMP.
E. TERMINATE DRAIN STACKS AT EXTERIOR WALL WITH DOWNWARD
FACING ELBOW LOCATED 18" AFF. ALL EXPOSED EXTERIOR PIPING
AND FITTINGS SHALL BE STEEL PAINTED TO MATCH EXTERIOR.
PROVIDE ESCUTCHEON TO TRIM PIPING AT FINISHED EXTERIOR. www.coffman.com
221 N. Wall Street, Suite 500
Spokane, WA 99201
ph 509.328.2994
32 MERCHANT STREET, SUITE 208
HONOLULU, HI 96813
808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND
VERIFY ALL DIMENSIONS AT JOB BEFORE
PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER
MY SUPERVISION AND CONSTRUCTION OF THIS
PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 992165TH FLOOR
REFRIGERANT AND
CONDENSATE PIPING
PLAN
P-115
FSC PROJECT NO. 21012
PERMIT SET
MAY 30, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce Lane
Spokane, WA 99206
(509) 919-0901
3/32" = 1'-0"
5TH FLOOR REFRIGERANT AND CONDENSATE PIPING PLAN
0'6'12'24'
SCALE: 3/32" = 1'-0"
KEY NOTES
1 ROUTE CONDENSATE LINE DOWN WALL AND CONNECT TO SINK
TAIL PIECE.
2 ROUTE RL/RS PIPING FROM BRANCH CONTROLLER (BC) TO FCU.
Revision Schedule
Number Description Date
5/30/2024
K
7
6
EFFICIENCY
129
L-1
S-1
WC-1
SH-1
2" W UP TO L-1 ON
FLOOR ABOVE
4" W DOWN TO
BELOW SLAB
4" W UP IN
CHASE ABOVE
2" W UP TO S-1 ON
FLOOR ABOVE
1-1/4" HW UP IN
CHASE ABOVE
1-1/4" CW UP IN
CHASE ABOVE
2" V UP IN
CHASE ABOVE
3/4" CONDENSATE
DRAIN UP
PTAC-1
2" UP IN WALL
TO WCO
2" V UP IN
CHASE ABOVE
WCO
C DC.1
3
2.1
2
EFFICIENCY ENLARGED
303
2" V UP IN WALL
ABOVE
S-1
L-1
WC-1
SH-1
2" W UP TO S-1 ON
FLOOR ABOVE
4" W UP TO WC-2
ON FLOOR ABOVE
2" W UP TO L-1 ON
FLOOR ABOVE
2" W UP TO SH-2
ON FLOOR ABOVE
1" CW UP & DN
3/4" HW UP &
1" HW DN
3/4" CONDENSATE
DRAIN UP & DN
2" V UP IN
CHASE
PTAC-1
WCO
2" UP IN WALL
TO WCO
2" W UP TO FD-1
4" W UP IN
CHASE
C DC.1
3
2.1
2
EFFICIENCY ENLARGED
203
1
1
S-1
L-1
WC-1
SH-1
4" W UP TO WC-1
ON FLOOR ABOVE
2" W UP TO SH-1
ON FLOOR ABOVE
1" CW UP &
1-1/4" CW DN
1" HW UP &
1-1/4" HW DN
3/4" CONDENSATE
DRAIN UP & DN
2" V UP IN
CHASE
PTAC-1
2" W UP IN
CHASE
N
7
6
DOUBLE QUEEN
135
PTAC-1
CO
2" V UP IN CHASE
2" W UP IN CHASE
1-1/4" HW UP IN
CHASE
1-1/4" CW UP IN
CHASE
SH-1
WC-1
L-1
S-1
2" W UP TO L-1
ABOVE
2" W UP TO L-1
ABOVE
4" W UP TO WC-1
ABOVE
2" UP IN WALL TO
WCO
WCO
3/4" CONDENSATE
DRAIN UP
A B
8.1
8
7
6.1
DOUBLE QUEEN ENLARGED
212
2" V UP & DN
IN CHASE
1-1/4" HW DN & 1" UP
IN CHASE
1-1/4" CW DN & 1" UP
IN CHASE
4" UP & DN IN CHASE
SH-1WC-1
L-1
WCO
S-1
2" W UP TO L-1 ON
FLOOR ABOVE
2" UP IN WALL
TO WCO
2" W UP TO SH-1
ON FLOOR ABOVE
2" W UP TO S-1 ON
FLOOR ABOVE
A B
8.1
8
7
6.1
DOUBLE QUEEN ENLARGED
412
WCO
SH-1WC-1
L-1
S-1
3/4" HW UP & 1" DN
2" V UP IN CHASE
3/4" CW UP & 1" DN
4" W DN IN CHASE
2" UP IN WALL
TO WCO ON
FLOOR ABOVE
2" V UP IN WALL
ABOVE
2" W UP TO SH-4
ON FLOOR
ABOVE
4" W UP TO WC-2 ON
FLOOR ABOVE
3/4" CONDENSATE
DRAIN UP & DN
PTAC
GENERAL NOTES
A. SIZES SHOWN ON THESE PLANS ARE ACCURATE FOR THESE
SPECIFIC ROOMS. FOR ROOM-SPECIFIC SIZES OF PIPES IN
CHASES, SEE RISER DIAGRAMS ON SHEETS P-601 THROUGH P-605.
PIPING SHOWN OUTSIDE OF PLUMBING CHASE IS TYPICAL FOR
ALL ROOMS OF THE SAME LAYOUT.
B. CONDENSATE RISER SERVING UPPER FLOORS TO EXIT BUILDING
EXTERIOR WALL AND TERMINATE AS AN ELBOW DOWN INTO
LANDSCAPING. EXPOSED PIPE SHALL BE COPPER OR STAINLESS
STEEL, NO PVC.
www.coffman.com
221 N. Wall Street, Suite 500
Spokane, WA 99201
ph 509.328.2994
32 MERCHANT STREET, SUITE 208
HONOLULU, HI 96813
808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND
VERIFY ALL DIMENSIONS AT JOB BEFORE
PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER
MY SUPERVISION AND CONSTRUCTION OF THIS
PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 99216ENLARGED PLUMBING
PLANS
P-401
FSC PROJECT NO. 21012
PERMIT SET
MAY 30, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce Lane
Spokane, WA 99206
(509) 919-0901
1/4" = 1'-0"1 ENLARGED PLUMBING PLAN - EFFICIENCY
1/4" = 1'-0"2 ENLARGED PLUMBING PLAN - EFFICIENCY ENLARGED
1/4" = 1'-0"3 ENLARGED PLUMBING PLAN - EFFICIENCY ADA-M-RI
1/4" = 1'-0"4 ENLARGED PLUMBING PLAN - DOUBLE QUEEN
1/4" = 1'-0"5 ENLARGED PLUMBING PLAN - DOUBLE QUEEN ENLARGED
1/4" = 1'-0"6 ENLARGED PLUMBING PLAN - DOUBLE QUEEN ADA-M-T
NOTE:
GUEST ROOMS ON THE FIFTH FLOOR ARE SERVED FROM PIPING IN FOURTH
FLOOR CEILING. THAT PIPING IS NOT SHOWN ON THESE PLANS FOR CLARITY,
REFER TO RISER DIAGRAMS ON SHEETS P-601 THROUGH P-605 FOR PIPE SIZES
AND CONNECTIONS, AND TO ENLARGED PLAN 2/P-403 FOR UNDERFLOOR
ROUTING.
3/4" CONDENSATE
DRAIN UP & DN
PTAC
Revision Schedule
Number Description Date
5/30/2024
K L.1
9
8
KING STUDIO
130
WC-1
L-1
SH-1
S-1
4" W UP TO WC-1 ON
FLOOR ABOVE
2" W UP TO L-1 ON
FLOOR ABOVE
2" UP IN WALL
ABOVE TO WCO
2" W UP TO SH-1 ON
FLOOR ABOVE
WCO
3/4" CONDENSATE
DRAIN UP
PTAC
2" V UP IN CHASE
1-1/4" HW UP IN CHASE
1-1/4" CW UP IN CHASE
4" W UP IN CHASE
P
9
8
KING STUDIO ADA-M-T
138
4" W UP TO WC-2 ON
FLOOR ABOVE
2" W UP TO L-2 ON
FLOOR ABOVE
2" UP IN WALL
ABOVE TO WCO
2" W UP TO SH-1 ON
FLOOR ABOVE
2" V UP IN CHASE
1-1/4" HW UP IN CHASE
1-1/4" CW UP IN CHASE
4" W UP IN CHASE
WCO
SH-4
L-2
WC-2
S-1
PTAC
3/4" CONDENSATE
DRAIN UP & DN
2" W UP TO S-1 ON
FLOOR ABOVE
B
2.1
1.1
2
KING 1-BEDROOM
202
4" W UP TO WC-1 ON
FLOOR ABOVE
2" W UP TO L-1 ON
FLOOR ABOVE
2" UP IN WALL
ABOVE TO WCO
2" W UP TO SH-1 ON
FLOOR ABOVE
2" V UP & DN IN CHASE
1" HW UP & 1-1/4" DN IN CHASE
1" CW UP & 1-1/4" DN IN CHASE
4" W UP IN CHASE
WCO
SH-1
L-1
WC-1
S-1
PTAC 3/4" CONDENSATE
DRAIN UP & DN
2" W UP TO S-1 ON
FLOOR ABOVE
2" W UP TO WB-1 ON
FLOOR ABOVE
PTAC
3/4" CONDENSATE
DRAIN UP & DN
C DC.1
1.1
2
KING 1-BEDROOM ENLARGED
201
4" W UP TO WC-2 ON
FLOOR ABOVE
2" W UP TO L-2 ON
FLOOR ABOVE
2" UP IN WALL
ABOVE TO WCO
2" W UP TO SH-1 ON
FLOOR ABOVE
2" V UP & DN IN CHASE
1" HW UP & 1-1/4" DN IN CHASE
1" CW UP & 1-1/4" DN IN CHASE
4" W UP IN CHASE
WCOSH-1
L-1
WC-1
2" W UP TO S-2 ON
FLOOR ABOVE
2" W UP TO WB-1 ON
FLOOR ABOVE
PTAC
3/4" CONDENSATE
DRAIN UP & DN
2" W TO WB-1
2" W TO S-2
2" VENT TO FLOOR
ABOVE
C DC.1
1.1
2
KING 1-BEDROOM ADA-M-T
301
4" W UP TO WC-1 ON
FLOOR ABOVE
2" W UP TO L-2 ON
FLOOR ABOVE
2" UP IN WALL
ABOVE TO WCO
2" W UP TO SH-1 ON
FLOOR ABOVE
2" V UP & DN IN CHASE
3/4" HW UP & 1" DN IN CHASE
3/4" CW UP & 1" DN IN CHASE
4" W UP & DN IN CHASE
WCO
SH-2
L-1 WC-2
2" W UP TO S-2 ON
FLOOR ABOVE
2" W UP TO WB-1 ON
FLOOR ABOVE
PTAC 3/4" CONDENSATE
DRAIN UP & DN
2" W TO WB-1
2" W TO S-22" VENT TO FLOOR
ABOVE
PTAC
S-2
3/4" CONDENSATE
DRAIN UP & DN
SH-1
WC-1
L-1
4" W4" W
2" W
2" W
4" W UP AND
DOWN IN SHAFT
CO
4" W UP AND
DOWN IN SHAFT
SLOPE 1/4" PER 12"
BACK TO MAIN (TYP)
2" V UP AND
DOWN IN WALL
2" V UP AND
DOWN IN WALL TO S-1 (ABOVE)
TO S-1
(BELOW)
TO L-1
(BELOW)
2" V
2" V
2" V
2" W
TO WCO ON
FLOOR ABOVE
GENERAL NOTES
A. SIZES SHOWN ON THESE PLANS ARE ACCURATE FOR THESE
SPECIFIC ROOMS. FOR ROOM-SPECIFIC SIZES OF PIPES IN
CHASES, SEE RISER DIAGRAMS ON SHEETS P-601 THROUGH P-605.
PIPING SHOWN OUTSIDE OF PLUMBING CHASE IS TYPICAL FOR
ALL ROOMS OF THE SAME LAYOUT.
B. CONDENSATE RISER SERVING UPPER FLOORS TO EXIT BUILDING
EXTERIOR WALL AND TERMINATE AS AN ELBOW DOWN INTO
LANDSCAPING. EXPOSED PIPE SHALL BE COPPER OR STAINLESS
STEEL, NO PVC.
www.coffman.com
221 N. Wall Street, Suite 500
Spokane, WA 99201
ph 509.328.2994
32 MERCHANT STREET, SUITE 208
HONOLULU, HI 96813
808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND
VERIFY ALL DIMENSIONS AT JOB BEFORE
PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER
MY SUPERVISION AND CONSTRUCTION OF THIS
PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 99216ENLARGED PLUMBING
PLANS
P-402
FSC PROJECT NO. 21012
PERMIT SET
MAY 30, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce Lane
Spokane, WA 99206
(509) 919-0901
1/4" = 1'-0"1 ENLARGED PLUMBING PLAN - KING STUDIO
1/4" = 1'-0"2 ENLARGED PLUMBING PLAN - KING STUDIO ADA-M-T
1/4" = 1'-0"4 ENLARGED PLUMBING PLAN - KING STUDIO 1 BEDROOM
1/4" = 1'-0"5 ENLARGED PLUMBING PLAN - 1 BEDROOM ENLARGED
1/4" = 1'-0"6 ENLARGED PLUMBING PLAN - KING 1 BEDROOM ADA-M-T
3 TYPICAL TOILET ROOM WASTE AND VENT PIPING
Revision Schedule
Number Description Date
5/30/2024
B
5
4
1-1/2" HWC
(LOW TEMP)
2-1/2" HW (165F)
TO LAUNDRY
FS-1 WH-1 WH-2 WH-3 WH-46" CW DN
1" G TO WH (TYP)
3" G DN
WATER SOFTENER (TYP 2)2" V DN RISER 6 SERVING FLOOR ABOVE
1" HW (140F)
TO KITCHEN
3/4" HWC
(140F)
2" G
4" HW
6" CW
3" G
6" CW
6" CW
HWC TO WHs -
SEE 1/P-502
RPBP
FS-1
FIRE HEADER
A B
8.1
8
7
6.1
NOTE:
GUEST ROOMS ON THE FIFTH FLOOR ARE
SERVED FROM HOT & COLD WATER
PIPING IN FOURTH FLOOR CEILING. THAT
PIPING IS SHOWN HALF-WIDTH ON THIS
PLAN FOR CLARITY. REFER TO RISER
DIAGRAMS ON SHEETS P-601 THROUGH
P-605 FOR PIPE SIZES AND
CONNECTIONS.
S-1
SH-4
WC-2
L-2
3" VTR
3/4" HW DN
3/4" CW DN
3/4" CONDENSATE
DRAIN DN
www.coffman.com
221 N. Wall Street, Suite 500
Spokane, WA 99201
ph 509.328.2994
32 MERCHANT STREET, SUITE 208
HONOLULU, HI 96813
808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND
VERIFY ALL DIMENSIONS AT JOB BEFORE
PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER
MY SUPERVISION AND CONSTRUCTION OF THIS
PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 99216ENLARGED WATER
HEATER ROOM
P-403
FSC PROJECT NO. 21012
PERMIT SET
MAY 30, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce Lane
Spokane, WA 99206
(509) 919-0901
3/8" = 1'-0"1 ENLARGED WATER HEATER ROOOM PLAN
1/4" = 1'-0"2 5TH FLOOR PLUMBING PLAN SERVED FROM 4TH FLOOR
Revision Schedule
Number Description Date
5/30/2024
6" DOMESTIC
WATER SUPPLY
PRESSURE GAUGE
FULL PORT BALL VALVE
6" STRAINER W/ BLOWDOWN,
WATTS MODEL 0825214
P P
6" RPBP, WATTS MODEL LF957,OSY
6" DOMESTIC
WATER TO FIXTURES
6" D
ROUTE TO
FLOOR SINK
P
6" PRV
WATTS MODEL
LFM115 150
NOTE: FOR TRAPEZE HANGER TAKE SPACING OF SMALLEST SIZE ON TRAPEZE.
MAXIMUM PIPE/TUBING SUPPORT SPACING
TUBING 5 FT
NOM. SIZE
PIPE 7
6 8 10
9 1110 12
1312 14
-16
1614 17 2219
TO 1000 LB. UNIFORM LOAD
TRAPEZE HANGER FOR UP
PROVIDE INSULATION SHIELD
AND INSERT FOR ALL PIPING (8" MIN.)
SIDE VIEW
1 5/8" 12 GAGE
CHANNEL OR 2"X2"X1/4"
ANGLE
SPACING ON 36" MAX.
HANGER RODS WITH
1/2" DIA. EACH CHANNEL
BAND
8 10645322 1/21 1/211 1/4IN.
FT.
FT.
THRU 3/4
7 7
7 981" MAX.ADJUSTABLE CLEVIS HANGER
TYPE 43 - SEE SPECIFICATIONS
PROVIDE HIGH COMPRESSIVE
STRENGTH INSULATION
(9 PCF MIN. DENSITY)
UNDER INSULATION SHIELD
TYPE 1 - SEE SPECIFICATIONS
ADJUSTABLE CLEVIS HANGER
HANGER ROD
INSULATION SHIELD AT HANGER
INSULATION (VAPOR BARRIER
TYPE IS REQUIRED FOR LOW
TEMPERATURE PIPE)
14"SQ.x4" DEEP CONCRETE
PAD, TROWEL SMOOTH AND
EDGE
1/8" BEND
WASTE LINE
MAY EXTEND AS WASTE
OR VENT
WALL
PLUGGED TEE W/
CLEANOUT
FINISHED FLOOR
1/8" BEND
WASTE LINE
FINISHED FLOOR
BALANCE OF PIPING SAME AS
CLEANOUT TO GRADE
FINISHED GRADE
WASTE LINE,
LENGTH TO SUIT
1/8" BEND IF CLEANOUT
OCCURS AT END OF LINE
CHROME WALLCOVER
& SCREW, USE TAMPER PROOF
SCREWS INSIDE BUILDING
1/8" BEND IF CLEANOUT
OCCURS AT END OF LINE
CLEANOUT AND ACCESS
COVER. TOP OF COVER TO
BE FLUSH W/ TOP OF FLOOR
1/8" BEND
BALANCE OF PIPING SAME
AS WALL CLEANOUT
DRAIN PIPE
CAULK INSIDE CONNECTION
GAS TIGHT PLUG
SCORIATED SECURED
CAST IRON COVER
CONCRETE SLAB
ON GRADE
FLOOR SLOPE,
SEE ARCH.
VAPOR BARRIER
ROCK BASE
FLOOR FINISH
WHERE OCCURS
FINISHED FLOOR
FLOOR DRAIN WITH
ADJUSTABLE HEIGHT STRAINER
RADIUS ALL
AROUND FOR
DISHED RECESS
FLOOR DRAIN
SEALANT ALL AROUND
1'-0"
SLOPE IN ADA ACCESSIBLE
RESTROOMS NOT TO EXCEED 1 IN 50.
WATERPROOF MEMBRANE,
WHERE SPECIFIED (SEE ARCH.)
CLAMP MEMBRANE
TIGHTLY INTO DRAIN COLLAR
1
1
FLOOR SINK
SEALANT ALL AROUND
FINISHED FLOOR
FLOOR FINISH WHERE OCCURS
SECOND LAYER 4'-0" SQUARE
VAPOR BARRIER TIGHTLY FITTED
AROUND PENETRATION AND
SEALED WITH TAPE
COMPACTED FILL
VAPOR BARRIER
CONCRETE SLAB
ON GRADE
TYPICAL LAVATORY
CONDENSATE DRAIN
DOWN IN WALL
CHROME PLATE ESCUTCHEON
COPPER DRAIN
RUBBER HOSE AND STAINLESS STEEL HOSE CLAMP
P-TRAP
NOTE: ADJUST ROUGH-
IN HEIGHT AS REQUIRED
BRANCH TAIL PIECE
(WALL HUNG LAV SHOWN.
CONDENSATE DRAIN
PIPING SIMILAR FOR
COUNTER TOP.)
FAN COIL
3/4" PUMPED
CONDENSATE LINE
CONDENSATE
COLLECTION HEADER
SLOPED AT 1% MIN.
OPEN VENT AT
UPPER END OF LINE
1"SEE PLANS FOR PIPE SIZING
MANUFACTURER PROVIDED
FLEXIBLE HOSE CONNECTION
MAX HEIGHT =24"
NOTE: FAN COIL HAS AN
INTERNAL CONDENSATE PUMP
3/4"
HUBLESS CAST IRON
UNDERDECK CLAMP
RIGID INSULATION
ROOF MEMBRANE
EXTENSION
INSULATED ROOF DRAIN LEADER
SUMP RECEIVER
ROOF DECK
DOMED STRAINER
NO-HUB COUPLING
OVERFLOW
STORM DRAIN
90° ELBOW
LENGTH AS
REQUIRED
OVERFLOW NOZZLE WITH
WALL FLANGE DS-1
18" MIN. WHEN
LOCATED AT
GRADE
OUTSIDE FINISH
SURFACE
FLOOR
PROVIDE BRONZE BIRD SCREEN.
SLIP INTO DOWNSPOUT NOZZLE
OPENING.
2"
FINISHED FLOOR
REMOVABLE GRATE W/ SUPPORT
AT SUMP. NOTCH FOR PIPING AND
ELECTRICAL
SP-1 / 2 W/ FLOATS AND OIL SENSORELEVATOR SUMP
SLEEVE AND SEAL AT
PENETRATIONS, TYP.36" MIN.LOCATE PIPE LOOP IN WALL
WALL
LAUNDRY TROUGH
DEHUMIDIFIER
POOL
AUT.
CHEMICAL
FEEDER
AUX.
POOL
HEATER
POOL
FILTER
AUXILIARY
PUMP
AUXILIARY
PUMP
DEHUMIDIFIER
FM
FM
BRINE TANK
WATER
SOFTENER
NOTES:
1.UNIONS SHOULD BE LOCATED ON INLET AND OUTLET
CONNECTIONS OF CONTROL VALVE TO FACILITATE SERVICING.
2.THE USE OF DISSIMILAR METALS IN A PIPING SYSTEM IS NOT
RECOMMENDED. WHERE DISSIMILAR METALS MUST BE
CONNECTED IN A WATER SYSTEM, THE USE OF
NONCONDUCTIVE (DIELECTRIC) FITTING MAY REDUCE
GALVANIC CORROSION.
3.PROVIDE AN AIR GAP OF AT LEAST FOUR TIMES THE DIAMETER
OF THE DRAIN PIPE OR CONFORM TO LOCAL SANITATION
CODES.
BYPASS VALVE
(NORMALLY CLOSED)
HARD WATER
INLET
SOFT WATER
OUTLET
MANUAL INLET VALVE
MANUAL OUTLET
VALVE CONTROLLER
WATER
SOFTENER
COUNTERTOP
GARBAGE DISPOSER
DRAIN PIPING
TO SANITARY
SYSTEM
DISHWASHER
DRAIN HOSE
SECURE HOSE
TO DISPOSER
WITH CLAMP
AIR GAP FITTING
DISHWASHER
SINK
www.coffman.com
221 N. Wall Street, Suite 500
Spokane, WA 99201
ph 509.328.2994
32 MERCHANT STREET, SUITE 208
HONOLULU, HI 96813
808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND
VERIFY ALL DIMENSIONS AT JOB BEFORE
PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER
MY SUPERVISION AND CONSTRUCTION OF THIS
PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 99216PLUMBING DETAILS
P-501
FSC PROJECT NO. 21012
PERMIT SET
MAY 30, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce Lane
Spokane, WA 99206
(509) 919-0901
NTS1WATER SERVICE ENTRY
NTS8TYPICAL PIPE HANGER
NTS5CLEANOUT DETAILS
NTS6FLOOR DRAIN SLAB ON GRADE
NTS7FLOOR SINK - SLAB ON GRADE
NTS4CONDENSATE DRAIN CONNECTION
NTS3FAN COIL CONDENSATE PIPING
NTS10DOMED ROOF DRAIN
NTS11OVERFLOW NOZZLE
NTS13ELEVATOR SUMP PUMP DETAIL
NTS12POOL HEATING SCHEMATIC FOR DEHUMIDIFIERS
NTS9WATER SOFTENER INSTALLATION
NTS2GUEST ROOM DISHWASHER WASTE DETAIL
Revision Schedule
Number Description Date
5/30/2024
RECIRC PUMP.
BALANCE VALVE
SET FOR 23.5 GPM
CHECK VALVE.5" PVC VENT4" PVC INTAKELINE SIZE
SUPPLY
4" COLD WATER
TO SYSTEM
2" DCW
P&T RELIEF
VALVE
TO FLOOR DRAIN
DRAIN VALVE WITH
THREADED HOSE
CONNECTION.
UNION
GAS
COCK
DIRT LEG
GAS
SUPPLY
SHUT-OFF
DIELECTRIC
UNIONS
WATER
HEATER
WATER
HEATER
WH WH
GGASME RATED EXTROL THERMAL
EXPANSION ABSORBER TANK
EXTROL NO, ST-120VC 1" DRAIN TO
FLOOR DRAIN
2"MIN 2"MIN
4" (120°) HOT
WATER
TO SYSTEM
1-1/2" (120°) HOT
WATER
RE-CIRC LINE
2.5" (165 F) HOT WATER
TO LAUNDRY
CP-1
MV-1
2" DCW
WATER
HEATER
WH
G1 2 4
2" HOT WATER
TO SYSTEM
FLOOR
DRAIN
WATER
HEATER
WH
G3
FLOOR
DRAIN
FLOOR
DRAIN
FLOOR
DRAIN
2" DHW4" CWMV-2
1" HWET-1
4" HW
1" CW
RECIRC PUMP.
BALANCE VALVE
3 GPM
CHECK VALVE.
CP-2
3/4" (140F) HOT WATER FROM
KITCHEN RE-CIRC LINE
ARMSTRONG BRAIN
MIXING VALVE
ARMSTRONG BRAIN
MIXING VALVE
1" (140°) HOT
WATER
TO KITCHEN
END VIEW
CLEVIS RING
PIPE
SIDE VIEW
PIPE
4
1
4
3
1
4
3
4
NOTES
HANGER RODS WITH STIFFENERS.
ANGLE IRON OR MANUFACTURED STRUT
CROSS MEMBER.
RIGID BRACE (SHOWN) OR MULTIPLE CABLE
BRACES.
SEE STRUCTURAL FOR ANCHORAGE.
1
2
3
4
6" DRIP LEG WITH CAP
CONNECTION TO
EQUIPMENT
CERTIFIED GAS FLEX LINE
GAS SUPPLY LINE
G
GAS SUPPLY LINE
CONNECTION TO
EQUIPMENT
CERTIFIED GAS FLEX LINE
6" DRIP LEG WITH CAP
LISTED GAS VALVE
UNION
PIPE REDUCER,
IF REQUIRED
UNION GLISTED GAS
VALVE
PIPING FROM
ABOVE
SUPPLY FROM ABOVE
HORIZONTAL SUPPLY
VERTICAL OFFSET
FOR DRIP LEG
GAS PRESSURE REGULATOR, SIZE
FOR SPECIFIC EQUIPMENT INLET
PRESSURE REQUIREMENTS
1/4" TEST PLUG, CAPPED (TYP. 2)
GAS PRESSURE REGULATOR, SIZE
FOR SPECIFIC EQUIPMENT INLET
PRESSURE REQUIREMENTS
1/4" TEST PLUG, CAPPED (TYP. 2)FLOW FROM MAIN
NOT ACCEPTABLE
ACCEPTABLE ACCEPTABLE
FLOW FROM MAIN
BRANCH CONNECTION
BRANCH CONNECTION
BRANCH CONNECTION FLOW FROM MAIN
BRANCH CONNECTIONBRANCH CONNECTION
REMOVABLE SHEET METAL COUNTERFLASHING
SHEET METAL FLASHING RECEIVER
SHEET METAL OR FLEX-TUBE COLLAR,
SEAL AROUND PIPING WITH SILICONE CAULK
SLOPE PIPES DOWN AND AWAY FROM HOOD
INSULATE VOID TO PREVENT CONDENSATION
SHEET METAL ENCLOSURE-CROSSBREAK OR SLOPE FOR DRAINAGE
FASTENERS APPROX. 8" O.C.
6"
4"
MIN. 4" CLEARANCE
FROM PIPE TO TOP OF CURB;
MIN. 2" BETWEEN PIPES10"NOMINAL FLASHINGHEIGHTWOOD NAILERS INSTALLED WITH
BOND BREAKERS AND FASTENED
AS SPECIFIED OR REQUIRED BY
CODE OR INDUSTRY STANDARDS
TO RESIST DESIGN LOADS AND
CORROSION OF STEEL DECKING,
FASTENERS AND METAL EDGING.
THERMAL INSULATION, COVERBOARD AND
ROOFING PLIES APPLIED TO DECK AS
SPECIFIED OR REQUIRED
HIGH-DOMED, CAPPED, GASKETED
FASTENERS (APPROX. 18" O.C.,
MINIMUM TWO FASTENERS PER SIDE)
FLASHING SHEETS, EXTEND
TO A MIN. HEIGHT OF 8"
ROOF MEMBRANE SHEETS, EXTEND 2"
MIN. ABOVE TOP OF CANT
NOTE:
THIS DETAIL MAY NOT EXACTLY
REPRESENT THE CONSTRUCTION OR
TYPE OF MATERIALS CURRENTLY
INSTALLED. CONTRACTOR SHALL USE
THIS DETAIL AS A GUIDE IN
CONJUNCTION WITH ROOF
MANUFACTURER'S FLASHING
INSTRUCTIONS.
NOTE:
CONTRACTOR MAY USE RPS PIPE
PORTAL SYSTEM (CURB, COVER, CAP,
AND CLAMPS) IN LIEU OF FABRICATED
SYSTEM SHOWN. INSTALL PER MFRS
INSTRUCTIONS.
NOTES:
1. PROVIDE ANCHORS ONLY WHERE
SHOWN ON DRAWINGS.
2. EXTEND SLEEVE ABOVE FLOOR
WHERE SPECIFIED.
BOLT (TYPICAL)
FLOOR SLAB
BACKING MATERIAL AND FIRE-
STOPPING (RATED FLOORS)
OR SILICONE CAULK (NON-
RATED FLOORS)
BOLT
PIPE
PIPE SLEEVE
WHERE SPECIFIED
RISER CLAMP
RISER
PIPE SLEEVE, WHERE
SPECIFIED
RISER CLAMP. BOTTOM
CLAMP REQUIRED AT
ANCHOR POINTS ONLY.
ELEVATION
PLAN
RISER CLAMP
GAS
WATER
HEATER
120°F DOMESTIC
HOT WATER SUPPLY
DOMESTIC HOT
WATER
RETURN
COLD WATER
T
T
AITANK DISCHARGE
TEMPERATURE
AI120°F SUPPLY
TEMPERATURE
DI
DO START /
STOP
STATUS
T
AI RETURN
TEMPERATURE
www.coffman.com
221 N. Wall Street, Suite 500
Spokane, WA 99201
ph 509.328.2994
32 MERCHANT STREET, SUITE 208
HONOLULU, HI 96813
808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND
VERIFY ALL DIMENSIONS AT JOB BEFORE
PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER
MY SUPERVISION AND CONSTRUCTION OF THIS
PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 99216PLUMBING DETAILS
P-502
FSC PROJECT NO. 21012
PERMIT SET
MAY 30, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce Lane
Spokane, WA 99206
(509) 919-0901
NTS1WATER HEATER DETAIL
NTS4SEISMIC BRACING FOR GAS PIPING
NTS5NATURAL GAS EQUIP. CONNECTION
NTS6TEES FOR COMBINED FLOW DETAIL
NTS2PIPE THROUGH ROOF
NTS7SUPPORT ANCHOR FOR PIPE RISERS
NTS3GAS WATER HEATER CONTROL DIAGRAM
Revision Schedule
Number Description Date
5/30/2024
ROOF
5th FLOOR
4th FLOOR
3rd FLOOR
2nd FLOOR
S-1 L-1 SH-1 WC-1WB-1
2"2" 3" 4"4" 4" 4"2"
L-1 SH-4 WC-1 S-1 WB-12"1-1/2"2"2"1-1/2"2"2"2"2"2"4"4"4"4"3"3"3"3"4"4"3"3"S-1 L-1 SH-1 WC-1
2" 3" 4"4" 3" 2"
WC-1 SH-1 L-1 S-11-1/2"2"2"1-1/2"2"2"2"2"3"3"S-1 L-1 SH-1 WC-1
2" 3" 4"4" 3" 2"
WC-1 SH-1 L-1 S-11-1/2"2"2"1-1/2"2"2"2"2"4"4"2"2"S-1 L-1 SH-1 WC-1
2" 3" 4"4" 3" 2"
WC-1 SH-1 L-1 S-11-1/2"2"2"1-1/2"2"2"2"2"4"4"2"2"S-1 L-1 SH-1 WC-1
2" 3" 4"4" 3" 2"
WC-1 SH-1 L-1 S-11-1/2"2"2"1-1/2"2"2"2"2"4"4"GROUND FLOOR
UNDERFLOOR
S-1 L-1 SH-1 WC-1WB-1
2"2" 3" 4"4" 3" 2"2"
WC-1 SH-1 L-1 S-1 WB-12"1-1/2"2"2"1-1/2"2"2"2"2"2"4"4"S-1 L-1 SH-1 WC-1WB-1
2"2" 3" 4"2"1-1/2"2"2"2"4"3"3"2"2"S-1 L-1 SH-1 WC-1WB-1
2"2" 3" 4"2"1-1/2"2"2"2"
4" 3" 2"2"
WC-1 SH-1 L-1 S-1 WB-12"1-1/2"2"2"2"4"4" 3" 2"2"
WC-1 SH-1 L-1 S-1 WB-12"1-1/2"2"2"2"
RISER-1 RISER-2 RISER-3 RISER-64"4"3"3"4" 3" 2"
WC-1 SH-1 L-1 S-12"1-1/2"2"2"3"3"4" 3" 2"
WC-1 SH-1 L-1 S-12"1-1/2"2"2"4"4"3"3"S-1 L-1 SH-1 WC-1
2" 3" 4"4" 3" 2"
WC-1 SH-1 L-1 S-11-1/2"2"2"1-1/2"2"2"2"2"4"4"2"2"S-1 L-1 SH-1 WC-1
2" 3" 4"4" 3" 2"
WC-1 SH-1 L-1 S-11-1/2"2"2"1-1/2"2"2"2"2"4"4"RISER-4 RISER-5 4"3"4" 3" 2"
WC-1 SH-1 L-1 S-12"1-1/2"2"2"3"4" 3" 2"
WC-1 SH-1 L-1 S-12"1-1/2"2"2"4"3"4" 3" 2"
WC-1 SH-1 L-1 S-12"1-1/2"2"2"4"RISER-7 4"4"3"3"S-1 L-1 SH-1 WC-1
2" 3" 4"4" 3" 2"
WC-1 SH-1 L-1 S-11-1/2"2"2"1-1/2"2"2"2"2"3"3"S-1 L-1 SH-1 WC-1
2" 3" 4"4" 3" 2"
WC-1 SH-1 L-1 S-11-1/2"2"2"1-1/2"2"2"2"2"4"4"2"3"S-1 L-1 SH-1 WC-1
2" 3" 4"4" 3" 2"
WC-1 SH-1 L-1 S-11-1/2"2"2"1-1/2"2"2"2"2"4"4"2"3"S-1 L-1 SH-1 WC-1
2" 3" 4"4" 3" 2"
WC-1 SH-1 L-1 S-11-1/2"2"2"1-1/2"2"2"2"2"4"4"RISER-8 RISER-9 4"3"S-1 L-1 SH-1 WC-1
2" 3" 4"1-1/2"2"2"2"3"S-1 L-1 SH-1 WC-1
2" 3" 4"1-1/2"2"2"2"4"2"S-1 L-1 SH-1 WC-1
2" 3" 4"1-1/2"2"2"2"4"2"S-1 L-1 SH-1 WC-1
2" 3" 4"1-1/2"2"2"2"4"RISER-10 4"3"S-1 L-1 SH-1 WC-1
2" 3" 4"1-1/2"2"2"2"3"S-1 L-1 SH-1 WC-1
2" 3" 4"1-1/2"2"2"2"4"2"S-1 L-1 SH-1 WC-1
2" 3" 4"1-1/2"2"2"2"4"2"S-1 L-1 SH-1 WC-1
2" 3" 4"1-1/2"2"2"2"4"RISER-11
WCO WCO
WCO
WCO
WCO WCO
WCO
WCO
WCO
WCO
WCO WCO
WCO
WCO
WCO WCO
WCO
WCO
WCO
WCO
WCO
WCO WCO
WCO
WCO
WCO WCO
WCO
WCO
WCO WCO
WCO
WCO
WCOWCO
WCO
WCO
WCO
WCO
WCO
WCO
2"
4"4"
4"
2"
L-1SH-2WC-1S-1WB-1 2"1-1/2"2"WCO
2"
4"4"4"2"
L-1SH-4WC-1S-1WB-1 2"1-1/2"2"WCO
2"
BOH FIXTURES BOH FIXTURES3"3"3"2"
FD-1
5th FLOOR
4th FLOOR
3rd FLOOR
2nd FLOOR
4"4"3"3"S-1 L-1 SH-1 WC-1
2" 3" 4"4" 3" 2"
WC-1 SH-1 L-1 S-11-1/2"2"2"1-1/2"2"2"2"2"3"3"S-1 L-1 SH-1 WC-1
2" 3" 4"4" 3" 2"
WC-1 SH-1 L-1 S-11-1/2"2"2"1-1/2"2"2"2"2"4"4"2"2"S-1 L-1 SH-1 WC-1
2" 3" 4"4" 3" 2"
WC-1 SH-1 L-1 S-11-1/2"2"2"1-1/2"2"2"2"2"4"4"2"2"S-1 L-1 SH-1 WC-1
2" 3" 4"4" 3" 2"
WC-1 SH-1 L-1 S-11-1/2"2"2"1-1/2"2"2"2"2"4"4"RISER-12 RISER-13 4"4"3"3"S-1 L-1 SH-3 WC-1
2" 3" 4"4" 3" 2"
WC-1 SH-3 L-1 S-11-1/2"2"2"1-1/2"2"2"2"2"3"3"S-1 L-1 SH-3 WC-1
2" 3" 4"4" 3" 2"
WC-1 SH-3 L-1 S-11-1/2"2"2"1-1/2"2"2"2"2"4"4"2"2"S-1 L-1 SH-3 WC-1
2" 3" 4"4" 3" 2"
WC-1 SH-3 L-1 S-11-1/2"2"2"1-1/2"2"2"2"2"4"4"2"2"S-1 L-1 SH-3 WC-1
2" 3" 4"4" 3" 2"
WC-1 SH-3 L-1 S-11-1/2"2"2"1-1/2"2"2"2"2"4"4"RISER-15 RISER-164"3"4" 3" 2"
WC-1 SH-1 L-1 S-12"1-1/2"2"2"3"4" 3" 2"
WC-1 SH-1 L-1 S-12"1-1/2"2"2"4"2"4" 3" 2"
WC-1 SH-1 L-1 S-12"1-1/2"2"2"4"2"4" 3" 2"
WC-1 SH-1 L-1 S-12"1-1/2"2"2"4"RISER-14 4"4"3"3"S-1 L-1 SH-1 WC-1
2" 3" 4"4" 3" 2"
WC-1 SH-1 L-1 S-11-1/2"2"2"1-1/2"2"2"2"2"3"3"S-1 L-1 SH-1 WC-1
2" 3" 4"4" 3" 2"
WC-1 SH-1 L-1 S-11-1/2"2"2"1-1/2"2"2"2"2"4"4"2"2"S-1 L-1 SH-1 WC-1
2" 3" 4"4" 3" 2"
WC-1 SH-1 L-1 S-11-1/2"2"2"1-1/2"2"2"2"2"4"4"2"2"S-1 L-1 SH-1 WC-1
2" 3" 4"4" 3" 2"
WC-1 SH-1 L-1 S-11-1/2"2"2"1-1/2"2"2"2"2"4"4"RISER-17 RISER-18 4"4"3"3"S-1 L-1 SH-1 WC-1
2" 3" 4"4" 3" 2"
WC-1 SH-1 L-1 S-11-1/2"2"2"1-1/2"2"2"2"2"3"3"S-1 L-1 SH-1 WC-1
2" 3" 4"4" 3" 2"
WC-1 SH-1 L-1 S-11-1/2"2"2"1-1/2"2"2"2"2"4"4"2"2"S-1 L-1 SH-1 WC-1
2" 3" 4"4" 3" 2"
WC-1 SH-1 L-1 S-11-1/2"2"2"1-1/2"2"2"2"2"4"4"2"2"S-1 L-1 SH-1 WC-1
2" 3" 4"4" 3" 2"
WC-1 SH-1 L-1 S-11-1/2"2"2"1-1/2"2"2"2"2"4"4"RISER-19 RISER-20 4"4"3"3"S-1 L-1 SH-1 WC-1
2" 3" 4"4" 3" 2"
WC-1 SH-1 L-1 S-11-1/2"2"2"1-1/2"2"2"2"2"3"3"S-1 L-1 SH-1 WC-1
2" 3" 4"4" 3" 2"
WC-1 SH-1 L-1 S-11-1/2"2"2"1-1/2"2"2"2"2"4"4"2"3"S-1 L-1 SH-1 WC-1
2" 3" 4"4" 3" 2"
WC-1 SH-1 L-1 S-11-1/2"2"2"1-1/2"2"2"2"2"4"4"2"3"S-1 L-1 SH-1 WC-1
2" 3" 4"4" 3" 2"
WC-1 SH-1 L-1 S-11-1/2"2"2"1-1/2"2"2"2"2"4"4"RISER-21 RISER-22
ROOF
GROUND FLOOR
UNDERFLOOR
WCO
WCO
WCO
WCO WCO
WCO
WCO
WCO WCO
WCO
WCO
WCO WCO
WCO
WCO
WCO WCO
WCO
WCO
WCOWCO
WCO
WCO
WCO WCO
WCO
WCO
WCO WCO
WCO
WCO
WCO WCO
WCO
WCO
WCO WCO
WCO
WCO
WCO WCO
WCO
WCO
WCO
BF-12"3"KITCHEN FIXTURES
www.coffman.com
221 N. Wall Street, Suite 500
Spokane, WA 99201
ph 509.328.2994
32 MERCHANT STREET, SUITE 208
HONOLULU, HI 96813
808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND
VERIFY ALL DIMENSIONS AT JOB BEFORE
PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER
MY SUPERVISION AND CONSTRUCTION OF THIS
PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 99216WASTE AND VENT
RISER DIAGRAM
P-601
FSC PROJECT NO. 21012
PERMIT SET
MAY 30, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce Lane
Spokane, WA 99206
(509) 919-0901
NTS1WASTE & VENT RISER DIAGRAM 1
NTS2WASTE & VENT RISER DIAGRAM 2
Revision Schedule
Number Description Date
5/30/2024
ROOF
5th FLOOR
4th FLOOR
3rd FLOOR
2nd FLOOR
GROUND FLOOR
UNDERFLOOR 3"4" 3" 2"
WC-1 SH-1 L-1 S-12"1-1/2"2"2"3"4" 3" 2"
WC-1 SH-1 L-1 S-12"1-1/2"2"2"4"3"4" 3" 2"
WC-1 SH-1 L-1 S-12"1-1/2"2"2"4"2"4" 3" 2"
WC-1 SH-1 L-1 S-12"1-1/2"2"2"4"RISER-23 4"4"3"3"S-1 L-1 SH-1 WC-1
2" 3" 4"4" 3" 2"
WC-1 SH-1 L-1 S-11-1/2"2"2"1-1/2"2"2"2"2"3"3"S-1 L-1 SH-1 WC-1
2" 3" 4"4" 3" 2"
WC-1 SH-1 L-1 S-11-1/2"2"2"1-1/2"2"2"2"2"4"4"3"3"S-1 L-1 SH-1 WC-1
2" 3" 4"4" 3" 2"
WC-1 SH-1 L-1 S-11-1/2"2"2"1-1/2"2"2"2"2"4"4"2"2"S-1 L-1 SH-1 WC-1
2" 3" 4"4" 3" 2"
WC-1 SH-1 L-1 S-11-1/2"2"2"1-1/2"2"2"2"2"4"4"RISER-24 RISER-25
4"4" 3" 2"
WC-1 SH-1 L-12"2"4"S-1 L-1 SH-1 WC-1
2" 3" 4"4" 3" 2"
WC-1 SH-1 L-1 S-11-1/2"2"2"1-1/2"2"2"2"2"4"4"3"3"S-1 L-1 SH-1 WC-1
2" 3" 4"4" 3" 2"
WC-1 SH-3 L-1 S-11-1/2"2"2"1-1/2"2"2"2"2"3"3"S-1 L-1 SH-1 WC-1
2" 3" 4"4" 3" 2"
WC-1 SH-3 L-1 S-11-1/2"2"2"1-1/2"2"2"2"2"4"4"3"3"S-1 L-1 SH-1 WC-1
2" 3" 4"4" 3" 2"
WC-1 SH-3 L-1 S-11-1/2"2"2"1-1/2"2"2"2"2"4"4"2"2"S-1 L-1 SH-1 WC-1
2" 3" 4"4" 3" 2"
WC-1 SH-3 L-1 S-11-1/2"2"2"1-1/2"2"2"2"2"4"4"RISER-26 RISER-27
S-1 L-1 SH-1 WC-1
2" 3" 4"4" 3" 2"
WC-1 SH-3 L-1 S-11-1/2"2"2"1-1/2"2"2"2"2"4"4"3"3"S-1 L-1 SH-1 WC-1
2" 3" 4"4" 3" 2"
WC-1 SH-1 L-1 S-11-1/2"2"2"1-1/2"2"2"2"2"3"3"S-1 L-1 SH-1 WC-1
2" 3" 4"4" 3" 2"
WC-1 SH-1 L-1 S-11-1/2"2"2"1-1/2"2"2"2"2"4"4"3"3"S-1 L-1 SH-1 WC-1
2" 3" 4"4" 3" 2"
WC-1 SH-1 L-1 S-11-1/2"2"2"1-1/2"2"2"2"2"4"4"2"2"S-1 L-1 SH-1 WC-1
2" 3" 4"4" 3" 2"
WC-1 SH-1 L-1 S-11-1/2"2"2"1-1/2"2"2"2"2"4"4"RISER-28 RISER-29
S-1 L-1 SH-1 WC-1
2" 3" 4"4" 3" 2"
WC-1 SH-1 L-1 S-11-1/2"2"2"1-1/2"2"2"2"2"4"4"3"3"S-1 L-1 SH-1 WC-1
2" 3" 4"4" 3" 2"
WC-1 SH-1 L-1 S-11-1/2"2"2"1-1/2"2"2"2"2"3"3"S-1 L-1 SH-1 WC-1
2" 3" 4"4" 3" 2"
WC-1 SH-1 L-1 S-11-1/2"2"2"1-1/2"2"2"2"2"4"4"3"3"4" 3" 2"
WC-1 SH-1 L-1 S-12"1-1/2"2"2"4"4"2"2"4" 3" 2"
WC-1 SH-1 L-1 S-12"1-1/2"2"2"4"4"RISER-30 RISER-31
4" 3" 2"
WC-1 SH-1 L-1 S-12"1-1/2"2"2"
4"3"2"
L-1SH-2WC-1S-1 2"1-1/2"2"2"
4"3"2"
L-1SH-4WC-1S-1 2"1-1/2"2"2"
4"3"2"
L-1SH-4WC-1S-1 2"1-1/2"2"2"2"2"2"2"2"2"WCOWCO
WCO
WCO
WCO
WCO WCO
WCO
WCO
WCO
WCO WCO
WCO
WCO
WCO
WCO WCO
WCO
WCO
WCO
WCO WCO
WCO
WCO
WCO
WCO
WCO
WCO
WCO
WCO WCO
WCO
WCO
WCO
WCO WCO
WCO
WCO WCO
WCO
WCO
WCO
WCO WCO
WCO
2"www.coffman.com
221 N. Wall Street, Suite 500
Spokane, WA 99201
ph 509.328.2994
32 MERCHANT STREET, SUITE 208
HONOLULU, HI 96813
808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND
VERIFY ALL DIMENSIONS AT JOB BEFORE
PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER
MY SUPERVISION AND CONSTRUCTION OF THIS
PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 99216WASTE AND VENT
RISER DIAGRAM
P-602
FSC PROJECT NO. 21012
PERMIT SET
MAY 30, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce Lane
Spokane, WA 99206
(509) 919-0901
NTS1WASTE & VENT RISER DIAGRAM 3
Revision Schedule
Number Description Date
5/30/2024
ROOF
5th FLOOR
4th FLOOR
3rd FLOOR
2nd FLOOR
GROUND FLOOR
UNDERFLOOR
RISER-1 RISER-2
WB-1 L-1 WC-1 SH-1S-11/2"1/2"1/2"1/2"1/2"1/2"1/2"1/2"1-1/4"1-1/4"1/2"
1/2"
3/4"
1/2"3/4"
L-1WC-1SH-1 1/2"1/2"1/2"1/2"1/2"1/2"1/2"1/2"1-1/4"1-1/4"1/2"
1/2"
3/4"
1/2"3/4"
WB-1 L-1 WC-1 SH-1S-11/2"1/2"1/2"1/2"1/2"1/2"1/2"1/2"1"1"1/2"
1/2"
3/4"
1/2"3/4"
L-1WC-1SH-4 1/2"1/2"1/2"1/2"1/2"1/2"1/2"1/2"1"1"1/2"
1/2"
3/4"
1/2"3/4"
WB-1 L-1 WC-1 SH-1S-11/2"1/2"1/2"1/2"1/2"1/2"1/2"1/2"1/2"3/4"1/2"
1/2"
3/4"
1/2"
3/4"
3/4"
3/4"
S-1L-1WC-1SH-1 WB-11/2"1/2"1/2"1/2"1/2"1/2"1/2"1/2"1/2"3/4"1/2"
1/2"
3/4"
1/2"
3/4"
3/4"
3/4"
WB-1 L-1 WC-1 SH-1S-1
1"1"1/2"
1/2"
1/2"
1/2"
3/4"
1/2"3/4"
3/4"3/4"1/2"1/2"1/2"1/2"1/2"1/2"1/2"S-1L-1WC-1SH-1 WB-1
1/2"
1/2"
1/2"
1/2"
3/4"
1/2"3/4"
3/4"3/4"1/2"1/2"1/2"1/2"1/2"1/2"1/2"S-1 WB-1
S-1 WB-1
RISER-3
S-1 L-1 WC-1 SH-11/2"1/2"1/2"1/2"1/2"1/2"3/4"
1/2"3/4"
S-1 L-1 WC-1 SH-11/2"1/2"1/2"1/2"1/2"1/2"3/4"
1/2"3/4"
S-1 L-1 WC-1 SH-11/2"1/2"1/2"1/2"1/2"1/2"3/4"3/4"
1/2"
S-1 L-1 WC-1 SH-1
1/2"
1/2"
3/4"
1/2"1/2"1/2"1/2"1/2"RISER-4
S-1 L-1 WC-1 SH-11/2"1/2"1/2"1/2"1/2"1/2"3/4"
1/2"3/4"
S-1 L-1 WC-1 SH-11/2"1/2"1/2"1/2"1/2"1/2"3/4"
1/2"3/4"
S-1 L-1 WC-1 SH-21/2"1/2"1/2"1/2"1/2"1/2"3/4"3/4"
1/2"
S-1 L-1 WC-1 SH-4
1/2"
1/2"
3/4"
1/2"1/2"1/2"1/2"1/2"RISER-5
S-1L-1WC-1SH-1 1/2"1/2"1/2"1/2"1/2"1/2"3/4"
1/2"3/4"
S-1L-1WC-1SH-1 1/2"1/2"1/2"1/2"1/2"1/2"3/4"
1/2"3/4"
S-1L-1WC-1SH-1 1/2"1/2"1/2"1/2"1/2"1/2"3/4"3/4"
1/2"
S-1L-1WC-1SH-1
1/2"
1/2"
3/4"
1/2"1/2"1/2"1/2"1/2"RISER-6
S-1L-1WC-1SH-1 1/2"1/2"1/2"1/2"1/2"1/2"3/4"
1/2"3/4"
S-1L-1WC-1SH-1 1/2"1/2"1/2"1/2"1/2"1/2"3/4"
1/2"3/4"
S-1L-1WC-1SH-1 1/2"1/2"1/2"1/2"1/2"1/2"3/4"
1/2"
S-1L-1WC-1SH-1
1/2"
1/2"
3/4"
1/2"
1-1/4"1/2"1/2"1/2"1/2"RISER-7
S-1L-1WC-1SH-1 1/2"1/2"1/2"1/2"1/2"1/2"3/4"
1/2"3/4"
S-1L-1WC-1SH-1 1/2"1/2"1/2"1/2"1/2"1/2"3/4"
1/2"
S-1L-1WC-1SH-1
1/2"
1/2"
3/4"
1/2"
1-1/4"1/2"1/2"1/2"1/2"RISER-8
S-1 L-1 WC-1 SH-11/2"1/2"1/2"1/2"1/2"1/2"1"2"3/4"
1/2"3/4"
S-1 L-1 WC-1 SH-11/2"1/2"1/2"1/2"1/2"1/2"1"3/4"
1/2"3/4"
S-1 L-1 WC-1 SH-11/2"1/2"1/2"1/2"1/2"1/2"3/4"3/4"
1/2"
S-1 L-1 WC-1 SH-1
1/2"
1/2"
3/4"
1/2"1/2"1/2"1/2"1/2"RISER-9
S-1L-1WC-1SH-1 1/2"1/2"1/2"1/2"1/2"1/2"3/4"
1/2"3/4"
S-1L-1WC-1SH-1 1/2"1/2"1/2"1/2"1/2"1/2"1"3/4"
1/2"3/4"
S-1L-1WC-1SH-1 1/2"1/2"1/2"1/2"1/2"1/2"3/4"3/4"
1/2"
S-1L-1WC-1SH-4
1/2"
1/2"
3/4"
1/2"1/2"1/2"1/2"1/2"RISER-10
S-1 L-1 WC-1 SH-11/2"1/2"1/2"1/2"1/2"1"2"3/4"
1/2"3/4"
S-1 L-1 WC-1 SH-11/2"1/2"1/2"1/2"1/2"1"1-1/2"3/4"
1/2"3/4"
S-1 L-1 WC-1 SH-11/2"1/2"1/2"1/2"1/2"3/4"3/4"
1/2"
S-1 L-1 WC-1 SH-1
1/2"
1/2"
3/4"
1/2"1/2"1/2"1/2"1/2"RISER-11
S-1 L-1 WC-1 SH-11/2"1/2"1/2"1/2"1/2"1"2"3/4"
1/2"3/4"
S-1 L-1 WC-1 SH-11/2"1/2"1/2"1/2"1/2"1"1-1/2"3/4"
1/2"3/4"
S-1 L-1 WC-1 SH-11/2"1/2"1/2"1/2"1/2"3/4"3/4"
1/2"
S-1 L-1 WC-1 SH-1
1/2"
1/2"
3/4"
1/2"1/2"1/2"1/2"1/2"3/4 HWC"3/4 HWC"3/4 HWC"3/4 HWC"1/2"3/4"3/4"1/2"3/4"3/4"1/2"3/4"3/4"1/2"3/4"3/4"1-1/4"1-1/4"1/2"3/4"3/4"1"3/4"3/4"3/4 HWC"3/4 HWC"1/2"3/4"3/4"1/2"3/4"3/4"1"1"1/2"1-1/4"1-1/4"1-1/4"1-1/4"1"1"1"1"1/2"3/4"3/4"3/4"1/2"3/4"3/4"1"1"3/4"3/4"1/2"3/4"3/4"1/2"3/4 HWC"3/4 HWC"1/2"3/4"3/4"1/2"3/4"3/4"1/2"3/4"3/4"1/2"3/4"3/4"1-1/4"1-1/4"1-1/4"1-1/4"1"1"1"1/2"3/4"3/4"3/4"1/2"3/4"3/4"1"1"3/4"3/4"1/2"3/4"3/4"1/2"3/4 HWC"3/4 HWC"1/2"3/4"3/4"1/2"3/4"3/4"1/2"3/4"3/4"1/2"3/4"3/4"3/4 HWC"3/4 HWC"3/4 HWC"3/4 HWC"1-1/4"1-1/4"1"1"1/2"3/4"3/4"1"3/4"3/4"1/2"3/4 HWC"3/4 HWC"1/2"3/4"3/4"1/2"3/4"3/4"1-1/4"1-1/4"1"1"1/2"3/4"3/4"1"3/4"3/4"1/2"3/4 HWC"3/4 HWC"1/2"3/4"3/4"1/2"3/4"3/4"1-1/4"1-1/4"1/2"3/4"3/4"
3/4"3/4"1/2"3/4 HWC"3/4 HWC"1/2"3/4"3/4"1/2"3/4"3/4"1-1/4"1-1/4"1/2"3/4"3/4"
3/4"3/4"1/2"3/4 HWC"3/4 HWC"1/2"3/4"3/4"1"1"MANUAL CIRCUIT SETTER,
TYP. SET TO 0.75 GPM
3/4"
3/4"
3/4"
3/4"
3/4"
3/4"
3/4"
3/4"
3/4"
3/4"
3/4"
3/4"
3/4"
3/4"
3/4"
3/4"
3/4"
3/4"
ROOF
5th FLOOR
4th FLOOR
3rd FLOOR
2nd FLOOR
GROUND FLOOR
UNDERFLOOR
S-1 L-1 WC-1 SH-11/2"1/2"1/2"1/2"1/2"1/2"1/2"1-1/4"1-1/4"3/4"
1/2"3/4"
S-1 L-1 WC-1 SH-11/2"1/2"1/2"1/2"1/2"1/2"1/2"1"1"3/4"
1/2"3/4"
S-1 L-1 WC-1 SH-11/2"1/2"1/2"1/2"1/2"1/2"1/2"3/4"3/4"
1/2"
3/4"
3/4"
3/4"
S-1 L-1 WC-1 SH-1
1"1/2"
1/2"
3/4"
1/2"3/4"
3/4"3/41/2"1/2"1/2"1/2"1/2"S-1L-1WC-1SH-1 1/2"1/2"1/2"1/2"1/2"1/2"1/2"1-1/4"1-1/4"3/4"
1/2"3/4"
S-1L-1WC-1SH-1 1/2"1/2"1/2"1/2"1/2"1/2"1/2"1"1"3/4"
1/2"3/4"
S-1L-1WC-1SH-1 1/2"1/2"1/2"1/2"1/2"1/2"1/2"3/4"3/4"
1/2"
3/4"3/4"
S-1L-1WC-1SH-1
1"1/2"
1/2"
3/4"
1/2"
3/4"3/4"1/2"1/2"1/2"1/2"1/2"S-1L-1WC-1SH-1 1/2"1/2"1/2"1/2"1/2"1/2"3/4"
1/2"3/4"
S-1L-1WC-1SH-1 1/2"1/2"1/2"1/2"1/2"1/2"3/4"
1/2"3/4"
S-1L-1WC-1SH-1 1/2"1/2"1/2"1/2"1/2"1/2"3/4"
1/2"
S-1L-1WC-1SH-1
1/2"
1/2"
3/4"
1/2"1/2"1/2"1/2"1/2"S-1 L-1 WC-1 SH-31/2"1/2"1/2"1/2"1/2"1/2"3/4"
1/2"3/4"
S-1 L-1 WC-1 SH-31/2"1/2"1/2"1/2"1/2"1/2"3/4"
1/2"3/4"
S-1 L-1 WC-1 SH-31/2"1/2"1/2"1/2"1/2"1/2"3/4"
1/2"
S-1 L-1 WC-1 SH-3
1/2"
1/2"
3/4"
1/2"1/2"1/2"1/2"1/2"S-1L-1WC-1SH-3 1/2"1/2"1/2"1/2"1/2"1/2"3/4"
1/2"3/4"
S-1L-1WC-1SH-3 1/2"1/2"1/2"1/2"1/2"1/2"3/4"
1/2"3/4"
S-1L-1WC-1SH-3 1/2"1/2"1/2"1/2"1/2"1/2"3/4"
1/2"
S-1L-1WC-1SH-3
1/2"
1/2"
3/4"
1/2"1/2"1/2"1/2"1/2"S-1 L-1 WC-1 SH-11/2"1/2"1/2"1/2"1/2"1/2"3/4"
1/2"3/4"
S-1 L-1 WC-1 SH-11/2"1/2"1/2"1/2"1/2"1/2"3/4"
1/2"3/4"
S-1 L-1 WC-1 SH-11/2"1/2"1/2"1/2"1/2"1/2"3/4"
1/2"
S-1 L-1 WC-1 SH-1
1/2"
1/2"
3/4"
1/2"1/2"1/2"1/2"1/2"S-1L-1WC-1SH-1 1/2"1/2"1/2"1/2"1/2"1/2"3/4"
1/2"3/4"
S-1L-1WC-1SH-1 1/2"1/2"1/2"1/2"1/2"1/2"3/4"
1/2"3/4"
S-1L-1WC-1SH-1 1/2"1/2"1/2"1/2"1/2"1/2"3/4"
1/2"
S-1L-1WC-1SH-1
1/2"
1/2"
3/4"
1/2"1/2"1/2"1/2"1/2"S-1 L-1 WC-1 SH-11/2"1/2"1/2"1/2"1/2"1/2"3/4"
1/2"3/4"
S-1 L-1 WC-1 SH-11/2"1/2"1/2"1/2"1/2"1/2"3/4"
1/2"
1-1/4"
3/4"
1-1/4"
S-1 L-1 WC-1 SH-11/2"1/2"1/2"1/2"1/2"1/2"3/4"
1/2"
S-1 L-1 WC-1 SH-1
1/2"
1/2"
3/4"
1/2"1/2"1/2"1/2"1/2"S-1L-1WC-1SH-1 1/2"1/2"1/2"1/2"1/2"1/2"3/4"
1/2"3/4"
S-1L-1WC-1SH-1 1/2"1/2"1/2"1/2"1/2"1/2"3/4"
1/2"3/4"
S-1L-1WC-1SH-1 1/2"1/2"1/2"1/2"1/2"1/2"3/4"
1/2"
S-1L-1WC-1SH-1
1/2"
1/2"
3/4"
1/2"1/2"1/2"1/2"1/2"S-1 L-1 WC-1 SH-11/2"1/2"1/2"1/2"1/2"1/2"3/4"
1/2"3/4"
S-1 L-1 WC-1 SH-11/2"1/2"1/2"1/2"1/2"1/2"3/4"
1/2"3/4"
S-1 L-1 WC-1 SH-11/2"1/2"1/2"1/2"1-1/4"1/2"1/2"3/4"
1/2"
S-1 L-1 WC-1 SH-1
1/2"
1/2"
3/4"
1/2"1/2"1/2"1/2"1/2"S-1L-1WC-1SH-1 1/2"1/2"1/2"1/2"1-1/4"1/2"1/2"3/4"
1/2"3/4"
S-1L-1WC-1SH-1 1/2"1/2"1/2"1/2"1/2"1/2"3/4"
1/2"3/4"
S-1L-1WC-1SH-1 1/2"1/2"1/2"1/2"1-1/4"1/2"1/2"3/4"
1/2"
S-1L-1WC-1SH-1
1/2"
1/2"
3/4"
1/2"1/2"1/2"1/2"1/2"1-1/4"RISER-12 RISER-13 RISER-15 RISER-16RISER-14 RISER-17 RISER-18 RISER-19 RISER-20 RISER-21 RISER-22
3/4"3/4"3/4"3/4"
3/4"3/4"3/4"3/4"3/4" HWC3/4" HWC3/4" HWC3/4" HWC1/2"1-1/4"1-1/4"1/2"1"1"1/2"3/4"3/4"3/4"1"3/4"3/41/2"3/4"3/4"
3/4"3/4"3/4" HWC3/4" HWC1/2"1-1/4"1-1/4"1/2"1"1"1/2"3/4"3/4"3/4"1"3/4"3/41/2"3/4"3/4"
3/4"3/4"3/4" HWC3/4" HWC1/2"1-1/4"1-1/4"1/2"1"1"1/2"3/4"3/4"3/4"1"3/4"3/41/2"3/4"3/4"
3/4"3/4"3/4" HWC3/4" HWC1/2"1-1/4"1-1/4"1/2"1"1"1/2"3/4"3/4"3/4"1"3/4"3/41/2"3/4"3/4"
3/4"3/4"3/4" HWC3/4" HWC1/2"1-1/4"1-1/4"1/2"1"1"1/2"3/4"3/4"3/4"1"3/4"3/4"1/2"3/4"3/4"
3/4"3/4"3/4" HWC3/4" HWC1/2"1-1/4"1-1/4"1/2"1"1"1/2"3/4"3/4"3/4"1"3/4"3/4"1/2"3/4"3/4"
3/4"3/4"3/4" HWC3/4" HWC1/2"1-1/4"1-1/4"1/2"1"1"1/2"3/4"3/4"3/4"1"3/4"3/4"1/2"3/4"3/4"
3/4"3/4"3/4" HWC3/4" HWC1/2"1-1/4"1-1/4"1/2"1"1"1/2"3/4"3/4"3/4"1"3/4"3/4"1/2"3/4"3/4"
3/4"3/4"3/4" HWC3/4" HWC1/2"1-1/4"1-1/4"1/2"1"1"1/2"3/4"3/4"3/4"1"3/4"3/4"1/2"3/4"3/4"
3/4"3/4"3/4" HWC3/4" HWC3/4"
3/4"
3/4"
3/4"
3/4"
3/4"
3/4"
3/4"
3/4"
3/4"
3/4"
3/4"
3/4"
3/4"
3/4"
3/4"
3/4"
3/4"
3/4"
3/4"
www.coffman.com
221 N. Wall Street, Suite 500
Spokane, WA 99201
ph 509.328.2994
32 MERCHANT STREET, SUITE 208
HONOLULU, HI 96813
808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND
VERIFY ALL DIMENSIONS AT JOB BEFORE
PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER
MY SUPERVISION AND CONSTRUCTION OF THIS
PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 99216DOMESTIC WATER
RISER DIAGRAM
P-603
FSC PROJECT NO. 21012
PERMIT SET
MAY 30, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce Lane
Spokane, WA 99206
(509) 919-0901
NTS1DOMESTIC WATER RISER 1
NTS2DOMESTIC WATER RISER 2
3/4" HWC,
TYP.MANUAL CIRCUIT SETTER,
TYP. SET TO 0.75 GPM
Revision Schedule
Number Description Date
5/30/2024
ROOF
5th FLOOR
4th FLOOR
3rd FLOOR
2nd FLOOR
GROUND FLOOR
UNDERFLOOR
S-1L-1WC-1SH-1 1/2"1/2"1/2"1/2"1/2"1/2"3/4"
1/2"3/4"
S-1L-1WC-1SH-1 1/2"1/2"1/2"1/2"1/2"1/2"3/4"
1/2"3/4"
S-1L-1WC-1SH-1 1/2"1/2"1/2"1/2"1/2"1/2"3/4"
1/2"3/4"
S-1L-1WC-1SH-1
1/2"
1/2"
3/4"
1/2"3/4"1/2"1/2"1/2"1/2"RISER-23
1/2"3/4"
S-1L-1WC-1SH-1 1/2"1/2"1/2"1/2"1/2"1/2"3/4"
S-1 L-1 WC-1 SH-11/2"1/2"1/2"1/2"1/2"1/2"3/4"
1/2"3/4"
S-1 L-1 WC-1 SH-11/2"1/2"1/2"1/2"1/2"1/2"3/4"
1/2"3/4"
S-1 L-1 WC-1 SH-11/2"1/2"1/2"1/2"1/2"1/2"3/4"
1/2"
S-1 L-1 WC-1 SH-1
1/2"
1/2"
3/4"
1/2"1/2"1/2"1/2"1/2"S-1L-1WC-1SH-1 1/2"1/2"1/2"1/2"1/2"1/2"3/4"
1/2"3/4"
S-1L-1WC-1SH-1 1/2"1/2"1/2"1/2"1/2"1/2"3/4"
1/2"3/4"
S-1L-1WC-1SH-1 1/2"1/2"1/2"1/2"1/2"1/2"3/4"
1/2"
S-1L-1WC-1SH-1
1/2"
1/2"
3/4"
1/2"1/2"1/2"1/2"1/2"RISER-24 RISER-25
S-1 L-1 WC-1 SH-11/2"1/2"1/2"1/2"1/2"1/2"3/4"
1/2"3/4"
S-1L-1WC-1SH-1 1/2"1/2"1/2"1/2"1/2"1/2"3/4"
1/2"3/4"
S-1 L-1 WC-1 SH-11/2"1/2"1/2"1/2"1/2"1/2"3/4"
1/2"3/4"
S-1 L-1 WC-1 SH-11/2"1/2"1/2"1/2"1/2"1/2"3/4"
1/2"3/4"
S-1 L-1 WC-1 SH-11/2"1/2"1/2"1/2"1/2"1/2"3/4"
1/2"
S-1 L-1 WC-1 SH-1
1/2"
1/2"
3/4"
1/2"1/2"1/2"1/2"1/2"S-1L-1WC-1SH-3 1/2"1/2"1/2"1/2"1/2"1/2"3/4"
1/2"3/4"
S-1L-1WC-1SH-3 1/2"1/2"1/2"1/2"1/2"1/2"3/4"
1/2"3/4"
S-1L-1WC-1SH-3 1/2"1/2"1/2"1/2"1/2"1/2"3/4"
1/2"
S-1L-1WC-1SH-3
1/2"
1/2"
3/4"
1/2"1/2"1/2"1/2"1/2"RISER-26 RISER-27
S-1 L-1 WC-1 SH-11/2"1/2"1/2"1/2"1/2"1/2"3/4"
1/2"3/4"
S-1L-1WC-1SH-3 1/2"1/2"1/2"1/2"1/2"1/2"3/4"
1/2"3/4"
S-1 L-1 WC-1 SH-11/2"1/2"1/2"1/2"1/2"1/2"3/4"
1/2"3/4"
S-1 L-1 WC-1 SH-11/2"1/2"1/2"1/2"1/2"1/2"3/4"
1/2"3/4"
S-1 L-1 WC-1 SH-11/2"1/2"1/2"1/2"1/2"1/2"3/4"
1/2"
S-1 L-1 WC-1 SH-1
1/2"
1/2"
3/4"
1/2"1/2"1/2"1/2"1/2"S-1L-1WC-1SH-1 1/2"1/2"1/2"1/2"1/2"1/2"3/4"
1/2"3/4"
S-1L-1WC-1SH-1 1/2"1/2"1/2"1/2"1/2"1/2"3/4"
1/2"3/4"
S-1L-1WC-1SH-1 1/2"1/2"1/2"1/2"1/2"1/2"3/4"
1/2"
S-1L-1WC-1SH-1
1/2"
1/2"
3/4"
1/2"1/2"1/2"1/2"1/2"RISER-28 RISER-29
S-1 L-1 WC-1 SH-11/2"1/2"1/2"1/2"1/2"1/2"3/4"
1/2"3/4"
S-1L-1WC-1SH-1 1/2"1/2"1/2"1/2"1/2"1/2"3/4"
1/2"3/4"
S-1 L-1 WC-1 SH-41/2"1/2"1/2"1/2"1/2"1/2"3/4"
1/2"3/4"
S-1 L-1 WC-1 SH-41/2"1/2"1/2"1/2"1/2"1/2"3/4"
1/2"3/4"
S-1 L-1 WC-1 SH-11/2"1/2"1/2"1/2"1/2"1/2"3/4"
1/2"
S-1 L-1 WC-1 SH-1
1/2"
1/2"
3/4"
1/2"1/2"1/2"1/2"1/2"S-1L-1WC-1SH-1 1/2"1/2"1/2"1/2"1/2"1/2"3/4"
1/2"3/4"
S-1L-1WC-1SH-1 1/2"1/2"1/2"1/2"1/2"1/2"3/4"
1/2"3/4"
S-1L-1WC-1SH-1 1/2"1/2"1/2"1/2"1/2"1/2"3/4"
1/2"
S-1L-1WC-1SH-1
1/2"
1/2"
3/4"
1/2"
1-1/4"1/2"1/2"1/2"RISER-30 RISER-31
S-1 L-1 WC-1 SH-41/2"1/2"1/2"1/2"1/2"1/2"3/4"
1/2"3/4"
S-1L-1WC-1SH-1 1/2"1/2"1/2"1/2"1/2"1/2"3/4"
1/2"3/4"1-1/4"1-1/4"1/2"3/4"3/4"
3/4"3/4"1/2"3/4 HWC"3/4 HWC"1/2"3/4"1/2"3/4"1-1/4"1-1/4"1/2"3/4"3/4"
3/4"3/4"1/2"3/4 HWC"3/4 HWC"1/2"3/4"1/2"3/4"1"3/4"1"1"1-1/4"1-1/4"3/4"3/4"
3/4"
3/4"
3/4"
3/4"1-1/4"1-1/4"1/2"3/4"3/4"
3/4"1/2"3/4 HWC"3/4 HWC"1/2"3/4"1/2"3/4"1"3/4"1"1"1-1/4"1-1/4"3/4"3/4"
3/4"
3/4"
3/4"
3/4"1-1/4"1-1/4"1/2"3/4"3/4"
3/4"1/2"3/4 HWC"3/4 HWC"1/2"3/4"1/2"3/4"1"3/4"1"1"1-1/4"1-1/4"3/4"3/4"
3/4"
3/4"
3/4"
3/4"1-1/4"1-1/4"1/2"3/4"3/4"
3/4"1/2"3/4 HWC"3/4 HWC"1/2"3/4"1/2"3/4"1"3/4"1"1"1-1/4"1-1/4"3/4"3/4"
3/4"
3/4"
3/4"
3/4"1-1/4"1-1/4"1/2"3/4"3/4"
3/4"1/2"3/4 HWC"3/4 HWC"1/2"3/4"1/2"3/4"1"3/4"1"1"1-1/4"1-1/4"3/4"3/4"
3/4"
3/4"3/4"3/4"3/4"3/4"3/4"
3/4"
3/4"1/2"1/2"1/2"1/2"1/2"1-1/4"1-1/4"1/2"3/4"3/4"
3/4"3/4"1/2"3/4 HWC"3/4 HWC"1/2"3/4"1/2"3/4"
3/4"
3/4"1-1/4"1-1/4"1/2"3/4"3/4"
3/4"3/4"1/2"3/4 HWC"3/4 HWC"1/2"3/4"1/2"3/4"
3/4"
3/4"1-1/4"1-1/4"1/2"3/4"3/4"
3/4"3/4"1/2"3/4 HWC"3/4 HWC"1/2"3/4"1/2"3/4"
3/4"
3/4"1/2"1/2"1/2"1/2"3/4"3/4"3/4"3/4"
3/4"3/4"3/4"3/4"
3/4"3/4"3/4"3/4"3/4"3/4"3/4"3/4"1-1/4"1-1/4"3/4"3/4"1-1/4"1-1/4"1-1/4"1-1/4"3/4"1-1/4"1-1/4"3/4"MANUAL CIRCUIT SETTER,
TYP. SET TO 0.75 GPM
3/4" HWC, TYP.
www.coffman.com
221 N. Wall Street, Suite 500
Spokane, WA 99201
ph 509.328.2994
32 MERCHANT STREET, SUITE 208
HONOLULU, HI 96813
808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND
VERIFY ALL DIMENSIONS AT JOB BEFORE
PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER
MY SUPERVISION AND CONSTRUCTION OF THIS
PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 99216DOMESTIC WATER
RISER DIAGRAM
P-604
FSC PROJECT NO. 21012
PERMIT SET
MAY 30, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce Lane
Spokane, WA 99206
(509) 919-0901
NTS1DOMESTIC WATER RISER 3
Revision Schedule
Number Description Date
5/30/2024
5th FLOOR
4th FLOOR
3rd FLOOR
2nd FLOOR
GROUND FLOOR
UNDERFLOOR STACK-1 STACK-2 STACK-3 STACK-6STACK-4 STACK-5 STACK-7 STACK-8 STACK-9 STACK-10 STACK-11
PTAC-1
BALCONY3/4" D
3/4" D
PTAC-1
BALCONY3/4" D
3/4" D
PTAC-1
BALCONY3/4" D
3/4" D
PTAC-1
BALCONY3/4" D
3/4" D
PTAC-1
3/4" D
PTAC-1
3/4" D
PTAC-1
3/4" D
PTAC-1
3/4" D
PTAC-1
3/4" D
PTAC-1
3/4" D
PTAC-1
3/4" D
PTAC-1
3/4" D
PTAC-1
3/4" D
PTAC-1
3/4" D
PTAC-1
3/4" D
PTAC-1
3/4" D
PTAC-1
3/4" D
PTAC-1
3/4" D
PTAC-1
3/4" D
PTAC-1
BALCONY 3/4" D
3/4" D
PTAC-1
BALCONY 3/4" D
3/4" D
PTAC-1
BALCONY 3/4" D
3/4" D
PTAC-1
BALCONY 3/4" D
3/4" D
PTAC-1
BALCONY3/4" D
3/4" D
PTAC-1
BALCONY3/4" D
3/4" D
PTAC-1
BALCONY3/4" D
3/4" D
PTAC-1
BALCONY3/4" D
3/4" D
PTAC-1
BALCONY 3/4" D
3/4" D
PTAC-1
BALCONY 3/4" D
3/4" D
PTAC-1
BALCONY 3/4" D
3/4" D
PTAC-1
BALCONY 3/4" D
3/4" D
PTAC-1
BALCONY3/4" D
3/4" D
PTAC-1
BALCONY3/4" D
3/4" D
PTAC-1
BALCONY3/4" D
3/4" D
PTAC-1
BALCONY3/4" D
3/4" D
PTAC-1
3/4" D
PTAC-1
3/4" D
PTAC-1
3/4" D
PTAC-1
3/4" D
PTAC-1
3/4" D
PTAC-1
3/4" D
PTAC-1
3/4" D
PTAC-1
3/4" D
PTAC-1
3/4" D
STACK-12 STACK-13
PTAC-1
3/4" D
PTAC-1
3/4" D
PTAC-1
3/4" D
PTAC-1
3/4" D
PTAC-1
3/4" D
PTAC-1
3/4" D
PTAC-1
3/4" D
PTAC-1
3/4" D
PTAC-1
3/4" D
PTAC-1
3/4" D
STACK-14 STACK-15
PTAC-1
BALCONY 3/4" D
3/4" D
PTAC-1
BALCONY 3/4" D
3/4" D
PTAC-1
BALCONY 3/4" D
3/4" D
PTAC-1
BALCONY 3/4" D
3/4" D
PTAC-1
BALCONY 3/4" D
3/4" D
PTAC-1
BALCONY 3/4" D
3/4" D
PTAC-1
BALCONY 3/4" D
3/4" D
PTAC-1
BALCONY 3/4" D
3/4" D
PTAC-1
BALCONY 3/4" D
3/4" D
PTAC-1
BALCONY 3/4" D
3/4" D
STACK-16
PTAC-1
3/4" D
PTAC-1
3/4" D
PTAC-1
3/4" D
PTAC-1
3/4" D
PTAC-1
3/4" D
STACK-17
PTAC-1
3/4" D
PTAC-1
3/4" D
PTAC-1
3/4" D
PTAC-1
3/4" D
PTAC-1
3/4" D
5th FLOOR
4th FLOOR
3rd FLOOR
2nd FLOOR
GROUND FLOOR
UNDERFLOOR STACK-33
PTAC-1
BALCONY 3/4" D
3/4" D
PTAC-1
BALCONY 3/4" D
3/4" D
PTAC-1
BALCONY 3/4" D
3/4" D
PTAC-1
BALCONY 3/4" D
3/4" D
STACK-18
PTAC-1
3/4" D
PTAC-1
3/4" D
PTAC-1
3/4" D
PTAC-1
3/4" D
PTAC-1
3/4" D
STACK-20
PTAC-1
3/4" D
PTAC-1
3/4" D
PTAC-1
3/4" D
PTAC-1
3/4" D
STACK-19
PTAC-1
3/4" D
PTAC-1
3/4" D
PTAC-1
3/4" D
PTAC-1
3/4" D
PTAC-1
3/4" D
STACK-21
PTAC-1
3/4" D
PTAC-1
3/4" D
PTAC-1
3/4" D
PTAC-1
3/4" D
STACK-22
PTAC-1
3/4" D
PTAC-1
3/4" D
PTAC-1
3/4" D
PTAC-1
3/4" D
STACK-23
PTAC-1
3/4" D
PTAC-1
3/4" D
PTAC-1
3/4" D
PTAC-1
3/4" D
STACK-24
PTAC-1
3/4" D
PTAC-1
3/4" D
PTAC-1
3/4" D
PTAC-1
3/4" D
STACK-25
PTAC-1
3/4" D
PTAC-1
3/4" D
PTAC-1
3/4" D
PTAC-1
3/4" D
STACK-26
PTAC-1
3/4" D
PTAC-1
3/4" D
PTAC-1
3/4" D
PTAC-1
3/4" D
STACK-27
PTAC-1
3/4" D
PTAC-1
3/4" D
PTAC-1
3/4" D
PTAC-1
3/4" D
STACK-28
PTAC-1
3/4" D
PTAC-1
3/4" D
PTAC-1
3/4" D
PTAC-1
3/4" D
STACK-29
PTAC-1
3/4" D
PTAC-1
3/4" D
PTAC-1
3/4" D
PTAC-1
3/4" D
STACK-30
PTAC-1
3/4" D
PTAC-1
3/4" D
PTAC-1
3/4" D
PTAC-1
3/4" D
STACK-31
PTAC-1
3/4" D
PTAC-1
3/4" D
PTAC-1
3/4" D
PTAC-1
3/4" D
STACK-32
PTAC-1
3/4" D
PTAC-1
3/4" D
PTAC-1
3/4" D
PTAC-1
3/4" D
1", TYP. ALL
VERTICAL STACKS
GENERAL NOTES
A. TERMINATE DRAIN STACKS AT EXTERIOR WALL WITH DOWNWARD
FACING ELBOW LOCATED 18" AFF. ALL EXPOSED EXTERIOR PIPING
AND FITTINGS SHALL BE STEEL PAINTED TO MATCH EXTERIOR.
PROVIDE ESCUTCHEON TO TRIM PIPING AT FINISHED EXTERIOR.
B. ALL VERTICAL STACKS TO BE 1" PIPE.
www.coffman.com
221 N. Wall Street, Suite 500
Spokane, WA 99201
ph 509.328.2994
32 MERCHANT STREET, SUITE 208
HONOLULU, HI 96813
808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND
VERIFY ALL DIMENSIONS AT JOB BEFORE
PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER
MY SUPERVISION AND CONSTRUCTION OF THIS
PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 99216CONDENSATE DRAIN
RISER DIAGRAM
P-605
FSC PROJECT NO. 21012
PERMIT SET
MAY 30, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce Lane
Spokane, WA 99206
(509) 919-0901
NTS1CONDENSATE DRAIN RISER DIAGRAM 1
NTS2CONDENSATE DRAIN RISER DIAGRAM 2
Revision Schedule
Number Description Date
5/30/2024
PLUMBING FIXTURE SCHEDULE
CATALOG NUMBER BRANCH CONNECTIONS
TAG TYPE MFR FIXTURE TRIM SUPPLIES TRAP WASTE VENT CW HW NOTES
FD-1 FLOOR DRAIN SMITH 2005Y02-A05CP TRAP PRIMER -P-TRAP 2" 1-1/2" 1/2" - 10, 11
FS-1 FLOOR SINK CECO 906-2 TRAP PRIMER -P-TRAP 2" 1-1/2" 1/2" - 10, 12
FS-2 FLOOR SINK CECO 906-4 TRAP PRIMER -P-TRAP 4" 2" 1/2" - 10, 12
HB-1 HOSE BIBB, EXTERIOR WOODFORD 67-CH TEE KEY -- - - 3/4" -9
HB-2 HOSE BIBB, INTERIOR WOODFORD 24-CH TEE KEY -- - - 3/4" -15
BF-1 BOTTLE FILLER ELKAY LZWSM8K WALL BRACKET -P-TRAP 2" 1-1/2" 1/2" -3
WC-1 WATER CLOSET, FLUSH TANK, ADA KOHLER K-3999 KOHLER K-20110 SEAT, WITH COVER -- 4" 2" 1/2" -1
WC-2 WATER CLOSET, FLUSHOMETER, ADA KOHLER K-84325 OPEN FRONT SEAT, LESS COVER K-10TH00N10 - 4" 2" 1" -1, 2
U-1 URINAL KOHLER K-4991 -K-10UD00K20-CP - 2" 2" 3/4" - 1, 2, 3
L-1 LAV, COUNTERTOP STERLING 442007-U MOEN 6191 GRID DRAIN P-TRAP 2" 1-1/2" 1/2" 1/2"4
L-2 LAV, WALL MOUNT KOHLER K-2035-1 MOEN 6192 GRID DRAIN P-TRAP 2" 1-1/2" 1/2" 1/2"4
S-1 SINK, KITCHENETTE STERLING 11447 MOEN 7565 BASKET STRAINER P-TRAP 2" 1-1/2" 1/2" 1/2"4
S-2 SINK, LAUNDRY MUSTEE 24C UTILATWIN CHICAGO FAUCET W4D-DB6AE1-317ABCP -P-TRAP 2" 1-1/2" 1/2" 1/2"4
MB-1 MOP BASIN ADVANCE TABCO 9-OPC-84 CHICAGO FAUCET 897-RFC -P-TRAP 3" 2" 1/2" 1/2"7
SH-1 SHOWER MINCEYMARBLE TD-366-0S/SF-L 60X36 SHOWER, LEFT DRAIN 2 IN 1 DELTA 58472, OATEY 42045 DRAIN P-TRAP 2" 1-1/2" 1/2" 1/2"8
SH-2 SHOWER, ADA COMFORT DESIGNS SSB6238TR.75-WHG 62X38 SHOWER, FRONT CENTER DRAIN SLIDING HAND SHOWER DELTA 51361 WITH DELTA 52488 SHOWER HEAD, SEAT, INTEGRAL FRONT TRENCH DRAIN P-TRAP 2" 1-1/2" 1/2" 1/2" 5, 8, 16
SH-3 BATH/SHOWER KOHLER K-25831-LA 60X36 BATHTUB, LEFT DRAIN 2 IN 1 DELTA 58472, MOEN T2193 TUB FILL, GRID DRAIN P-TRAP 2" 1-1/2" 1/2" 1/2" 6, 8, 17
SH-4 BATH/SHOWER, ADA KOHLER K-25831-LA 60X36 BATHTUB, LEFT DRAIN SLIDING HAND SHOWER DELTA 51361, DELTA 52488 SHOWER HEAD, MOEN T2193 TUB FILL, GRID DRAIN P-TRAP 2" 1-1/2" 1/2" 1/2" 6, 8, 18
SH-5 SHOWER, ADA COMFORT DESIGNS SWB3838TR.75C.010 37X38 SHOWER, CENTER DRAIN SLIDING HAND SHOWER DELTA 51361 WITH DELTA 52488 SHOWER HEAD, GRID DRAIN P-TRAP 2" 1-1/2" 1/2" 1/2"8
WB-1 WATER BOX - CLOTHES WASHER GUY GRAY MWB-10 --P-TRAP 2" 1-1/2" 3/4" 3/4"1
WB-2 WATER BOX - WATER ONLY GUY GRAY MIB1 --- - - 1/2" -1
EW-1 EMERGENCY EYE WASH HAWS 7610 EMERGENCY SIGNAGE -- - - - 1/2"-
TD-1 TRENCH DRAIN, POOL DECK STEGMEIER -2" PVC DECK DRAIN -- 2" - - --
TD-2 TRENCH DRAIN, LAUNDRY H-M COMPANY HM-430 -LINT FILTER P-TRAP 6" - - -14
RD-1 ROOF DRAIN SMITH 1015Y03-R-C-CID UNDERDECK CLAMP, SUMP RECEIVER CAST IRON DOME - 2" - - --
OD-1 OVERFLOW DRAIN SMITH 1045Y03-R-C-CID UNDERDECK CLAMP, SUMP RECEIVER CAST IRON DOME - 2" - - --
DS-1 DOWNSPOUT NOZZLE SMITH 1770-BS --- - - - -13
1. PROVIDE & INSTALL WATER HAMMER ARRESTOR ON CW LINE SERVING FIXTURE, SEE PLAN FOR SIZE.
2. PROVIDE AND INSTALL SUPPORT CARRIER.
3. SEE ARCHITECTURAL FOR MOUNTING HEIGHT.
4. OFFSET EXPOSED TRAPS FOR ADA COMPLIANCE. INSULATE ALL EXPOSED PIPING (CW, HW, & SAN) BELOW SINK WITH TRUEBRO MODEL 102 & 105 HANDI LAV-GUARD KIT.
5. CONTRACTOR TO VERIFY REQUIRED SEAT ORIENTATION.
6. CONTRACTOR TO VERIFY REQUIRED DRAIN ORIENTATION.
7. PROVIDE AND INSTALL MOP HANGER, HOSE AND WALL BRACKET.
8. COORDINATE WITH ARCHITECT FOR GRAB BAR LOCATIONS.
9. KEY OPERATED QUARTER TURN, FREEZELESS, WITH BACKFLOW PREVENTER. VERIFY WALL THICKNESS WITH ARCHITECTURAL.
10. PROVIDE PRECISION PLUMBING PRODUCTS, INC. MODEL P1/P2 TRAP PRIMER. ROUTE 1/2" PIPING TO FLOOR DRAIN/SINK.
11. USE SQUARE STRAINER IN TILE FLOOR AND ROUND STRAINER IN CONCRETE FLOORS.
12. 12" SQUARE, 8" DEEP, COATED CAST IRON, ALUMINUM DOME BOTTOM STRAINER, WITH TRAP PRIMER CONNECTION.
13. SEE PLAN FOR SIZE; NOZZLE SHALL MATCH OVERFLOW RAIN LEADER SIZE.
14. PROVIDE A MINIMUM 1" GAP BETWEEN TROUGH AND DRAIN PIPE.
15. KEY OPERATED QUARTER TURN, WITH BACKFLOW PREVENTER. VERIFY WALL THICKNESS WITH ARCHITECTURAL.
16. ADA ROLL-IN SHOWER, CONTROLS ON BACK WALL, SEE ARCH FOR DETAILS. UNITS 338, 403.
17. SHOWER/TUB COMBO. SEE ARCH FOR DETAILS. UNITS 136, 222, 224, 236, 322, 324, 336, 422, 424, 436, 522, 524, 536.
18. ADA SHOWER, CONTROLS ON SHAFT WALL, OVERHEAD AND HANDHELD SHOWER HEAD W/ DIVERTER ON SHAFT WALL, SEE ARCH FOR DETAILS. UNITS 138, 238, 303, 503, 512
KITCHEN EQUIPMENT, PLUMBING CONNECTIONS
EQUIPMENT PLUMBING CONNECTIONS
QTY DESCRIPTION DIRECT WASTE VENT INDIRECT WASTE CW 140F HW 120F HW NG NOTES
2 HAND SINK 2"2"-1/2" - 1/2" -1,2
1 THREE COMPARTMENT SINK --2"1/2" 1/2" - -1,2
2 DISHWASHER, UNDERCOUNTER --3/4"- 3/4" - -1,2
1 PREP SINK --2"1/2" 1/2" - -1,2
1 MOP SINK 2"2"-1/2" 1/2" - -1,2
1 NUGGET ICE MAKER --3/4"1/2" - - -1,2
1 SINK 2"2"-1/2" - 1/2" -1,2
1 FLOOR TROUGH 4"2"-- - - -1,2
1 MAKE UP AIR UNIT --1-1/2"1/2" - - 1/2"1,2
1 DRAFT BEER COOLER ---1/2" - - -1,2
1 DISPOSAL 2"2"-- - - -1,2
1 ICE BIN --1"- - - -1,2
1 OUTDOOR GRILL ---- - - 1/2"1,2
1. OWNER PROVIDED, CONTRACTOR INSTALLED.
2. REFER TO KITCHEN EQUIPMENT PLANS FOR EQUIPMENT LOCATION.
DRAINAGE FIXTURE UNIT VALUES - PUBLIC
FIXTURE DESCRIPTION QTY.FIXTURE UNITS TOTAL
Drinking Fountain or Watercooler 2 0.5 1
Lavatory, single 139 1 139
Floor Drain, emergency 16 0 0
Floor Drain 1 2 2
Urinal, 1.0 GPF 2 2 4
Water Closet, 1.28 GPF flushometer valve 7 4 28
Water Closet, 1.28 GPF tank 132 4 528
Bathtub or Combination Bath/Shower 135 2 270
Clotheswasher, commercial, 3" standpipe 7 6 42
Sink, Laundry 1 2 2
Sink, Service or Mop Basin, 3" trap 5 3 15
Sink, Wash, each set of faucets 134 2 268
Sink, Kitchen, domestic with one 1-1/2" trap 2 2 4
Receptor, indirect waste, 2" trap, up to 7.5 gpm (1)2 1 2
Clotheswasher, domestic, 2" standpipe 8 3 24
Total Demand =1329
(1) FU DETERMINED BY TABLE 702.2(b).
FIXTURE UNITS OBTAINED FROM TABLE 702.1, UNIFORM PLUMBING CODE, 2018 EDITION.
WATER SUPPLY FIXTURE UNITS - PUBLIC
FIXTURE DESCRIPTION QTY.FIXTURE UNITS (1)TOTAL
Ice Maker 1 0.5 0.5
Drinking Fountain or Watercooler 2 0.5 1
Lavatory 139 1 139
Urinal, 1.0 GPF, flushometer valve 2 NOTE (2)20
Water Closet, 1.28 GPF Flushometer Valve 7 NOTE (2)135
Water Closet, 1.6 GPF Flushometer Tank 132 2.5 330
Clothes washer 18 4 72
Bathtub or Combination Bath/Shower 18 4 72
Shower, per head 116 2 232
Dishwasher, domestic 1 1.5 1.5
Sink, Kitchen, domestic 5 1.5 7.5
Sink, Laundry 1 1.5 1.5
Sink, Washup, each set of faucets 134 2 268
Sink, Service or Mop Basin 5 3 15
Hose Bibb (First one)1 2.5 2.5
Hose Bibb (Ea. additional)10 1 10
TOTAL DEMAND = 1307.5
(1) FIXTURE UNIT VALUES OBTAINED FROM TABLE 610.3.
(2) FLUSHOMETER VALVE FIXTURE UNITS FOR WATER CLOSETS AND URINALS
OBTAINED FROM TABLE 610.10.
LENGTH FROM METER TO REMOTE FIXTURE = 500'
PRESSURE RANGE (TABLE 6-5) =OVER 60 PSI
WATER METER SIZE = 6"
BUILDING SUPPLY SIZE = 6"
FIXTURE UNITS OBTAINED FROM UNIFORM PLUMBING CODE, 2018 EDITION.
WATER SOFTENERS SCHEDULE
TAG LOCATION SERVES MANUFACTURER/ MODEL
WATER FLOW PRESS. DROP TREATED WATER QUALITY (MAX)TANKS RESIN VOLUME RESIN
CAPACITY
ELECTRICAL REQUIOEMENTS
UNIT POWER REQ'T
WT. LBS.NOTES
GPM TEMP °F PEAK PSI TURBIDITY (NTU) CHLORINE (MG/L) IRON (MG/L)CONSTRUCTION QT'Y SIZE H X DIA TOTAL CF GRAINS VOLT ø MCA
WS-01 WATER HEATER
ROOM
DOMESTIC
WATER CULLIGAN/200 40-120 15 120 1 15 1,2
1. WATER SOFTENER SHALL INCLUDE A TEN FOOT (MINIMUM) POWER CORD WITH WALL MOUNT TRANSFORMER. RECEPTACLE SHALL BE PROVIDED, MARK SWITCH OR OTHERWISE LOCATE TO AVOID ACCIDENTAL DEACTIVATION.
2. INSTALL DRAIN WITH AIR GAP AT LEAST TWO TIMES THE DIAMETER OF THE DRAIN PIPE TO PERMIT OBSERVATION OF THE DRAIN FLOW.
NATURAL GAS CONNECTIONS
EQUIPMENT INPUT (BTH/H)NUMBER OF
UNITS CFH RUNOUT SIZE
(IN)
DUCT HEATER 400,000 1 400 3/4"
WATER HEATER 499,900 4 2,000 1"
ERV 550,000 1 550 1"
FIRE PIT 120,000 3 360 1/2"
BARBEQUE 74,500 1 75 1/2"
GENERATOR 1,882,000 1 1,882 1-1/2"
BOH DRYERS 150,000 3 450 1/2"
POOL HEATERS 500,000 2 1000 1"
MAU 123,000 1 123 1/2"
FUTURE 500,000 1 500 -
TOTAL 18 7,339 -
www.coffman.com
221 N. Wall Street, Suite 500
Spokane, WA 99201
ph 509.328.2994
32 MERCHANT STREET, SUITE 208
HONOLULU, HI 96813
808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND
VERIFY ALL DIMENSIONS AT JOB BEFORE
PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER
MY SUPERVISION AND CONSTRUCTION OF THIS
PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 99216PLUMBING SCHEDULES
P-701
FSC PROJECT NO. 21012
PERMIT SET
MAY 30, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce Lane
Spokane, WA 99206
(509) 919-0901
Revision Schedule
Number Description Date
5/30/2024
EXPANSION TANK SCHEDULE
MFR /
MODEL
TANK ACCEPT. SYSTEM CHARGE SYSTEM
VOLUME VOLUME VOLUME MIN. FILL MAX. SYS PRESS. PRESS. WEIGHT
TAG SERVICE TYPE (GAL) (GAL) (GAL) TEMP (F) TEMP (F) (PSIG) (PSIG) (LBS)NOTES
ET-1 DOMESTIC HOT WATER AMTROL / ST-120V-C DIA.68 35 950 48 170 12 125 850 (1)
(1) SECURE TANK TO CONCRETE FLOOR, SEE STRUCTURAL.
PLUMBING PUMP SCHEDULE
MFR MODEL IMP.HEAD MOTOR MOTOR UNIT ELECTRICAL REQUIREMENTS
TAG SERVICE NUMBER TYPE SIZE GPM FT H20 RPM SPEED VOLTS PHASE AMPS WATTS HP NOTES
DHWP-1 DHWC TO BUILDING BELL & GOSSETT PL-130 IN-LINE - 23.5 20 3200 CONSTANT 115 1 4.8 - 2/5 1, 2, 4
DHWP-2 DHWC TO KITCHEN BELL & GOSSETT ECOCIRC 20-18 IN-LINE - 3 10 3664 CONSTANT 115 1 1 - - 1, 3, 4
SP-1 ELEVATOR LIBERTY PUMP ELV-280 SUMP - 50 13 3450 CONSTANT 115 1 8 - 1/2 5, 6
SP-2 ELEVATOR LIBERTY PUMP ELV-280 SUMP - 50 13 3450 CONSTANT 115 1 8 - 1/2 5, 6
1. PROVIDE WITH BELL & GOSSETT CHECK-TROL CTF SERIES FLANGES.
2. PROVIDE AQUASTAT TO TURN PUMP ON AT 105°F AND OFF AT 115°F (ADJ.), AND TIMER TO TURN ON/OFF PUMP DURING OCCUPIED AND UNOCCUPIED TIMES.
3. PROVIDE AQUASTAT TO TURN PUMP ON AT 130°F AND OFF AT 135°F (ADJ.), AND TIMER TO TURN ON/OFF PUMP DURING OCCUPIED AND UNOCCUPIED TIMES.
4. 3 SPEED CIRCULATOR.
5. ELEVATOR SUMP PUMP. PROVIDE WITH CONTROL PANEL WITH OILTECTOR CONTROL, REMOTE ALARM, FLOATS, CHECK VALVE.
6. DISCONNECT SWITCH BY E.C.
GAS WATER HEATER SCHEDULE
MFR /
MODEL
INPUT TANK RECOVERY THERMAL UNIT ELECTRICAL REQUIREMENTS WEIGHT
TAG TYPE MBH CAPACITY GPH @ 100 F RISE EFFICIENCY VOLTS PHASE AMPS (LBS)LOCATION/SERVICE NOTES
WH-1 AO SMITH /
BTH-500 MXI DIRECT VENT, GAS 499.9 119 1152 95% 120 1 5 1850 WATER HEATER ROOM 1, 2, 3, 4
WH-2 AO SMITH /
BTH-500 MXI DIRECT VENT, GAS 499.9 119 1152 95% 120 1 5 1850 WATER HEATER ROOM 1, 2, 3, 4
WH-3 AO SMITH /
BTH-500 MXI DIRECT VENT, GAS 499.9 119 1152 95% 120 1 5 1850 WATER HEATER ROOM 1, 2, 3, 4
WH-4 AO SMITH /
BTH-500 MXI DIRECT VENT, GAS 499.9 119 1152 95% 120 1 5 1850 WATER HEATER ROOM 1, 2, 3, 4
1. PROVIDE AND INSTALL TEMPERATURE & PRESSURE RELIEF VALVE; ROUTE TO FLOOR SINK.
2. FLUE EXHAUST SHALL BE POLYPROPYLENE OR AL29-4C SS. INTAKE PIPING MAY BE SCHED 40 PVC.
3. SET HEATER TO 165 F.
4. PROVIDE WITH CONDENSATE NEUTRALIZATION KIT, PIPE TO FLOOR SINK.
www.coffman.com
221 N. Wall Street, Suite 500
Spokane, WA 99201
ph 509.328.2994
32 MERCHANT STREET, SUITE 208
HONOLULU, HI 96813
808-352-5299
NOTE: CONTRACTOR SHALL CHECK AND
VERIFY ALL DIMENSIONS AT JOB BEFORE
PROCEEDING WITH WORK.
OWNER:
THIS WORK WAS PREPARED BY ME OR UNDER
MY SUPERVISION AND CONSTRUCTION OF THIS
PROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTONSPOKANE VALLEY, WA13515 E. Carlisle AvenueSpokane Valley, WA 99216PLUMBING SCHEDULES
P-702
FSC PROJECT NO. 21012
PERMIT SET
MAY 30, 2024
GL8 Mirabeau
Point, LLC
TMK:PID: 45101.040110909 E. Pierce Lane
Spokane, WA 99206
(509) 919-0901
Revision Schedule
Number Description Date
5/30/2024
TVGTVWAPHPT1T2T4TELECOMMUNICATIONS SCHEDULESYMBOLDESCRIPTIONNOTESCCTV OUTLET(1) RG6 CABLEPROVIDE COAXIAL CABLE WITH F-TYPECONNECTOR PLUG FROM DEVICE TO PBX ROOMAND TERMINATE ON PATCH PANEL.GUEST UNIT DOORBELLDOORBELL SHALL BE CAPABLE OF MANUALSHUTOFF VIA SWITCH INSIDE GUEST UNIT.GUEST UNIT DATA/CCTV COMBINATION OUTLET1-PORT ACTIVE, 1-PORT BLANK, (1) CAT 6 CABLE,(1) RG6 CABLE.PROVIDE CAT-6 CABLE FROM DEVICE TO PBXROOM AND TERMINATE ON PATCH PANEL.GUEST UNIT DATA/WAP COMBINATION OUTLET1-PORT ACTIVE, 1-PORT BLANK, (1) CAT 6 CABLEWALL MOUNTED WAP PROVIDED BY OTHERSPROVIDE CAT-6 CABLE FROM DEVICE TO PBXROOM AND TERMINATE ON PATCH PANEL.PUBLIC AREA HOUSE PHONE1-PORT ACTIVE, 1-PORT BLANK, (1) CAT 6 CABLESMOUNT AT +48"VOICE/DATA OUTLET, TOTAL OF 2-PORTS1-PORT ACTIVE, 1-PORT BLANK, (1) CAT 6 CABLESUBSCRIPT DENOTES NUMBER OF ACTIVEPORTSVOICE/DATA OUTLET, TOTAL OF 4-PORTS2-PORTS ACTIVE, 2-PORTS BLANK, (2) CAT 6CABLESSUBSCRIPT DENOTES NUMBER OF ACTIVEPORTSVOICE/DATA OUTLET, TOTAL OF 6-PORTS4-PORTS ACTIVE, 2-PORTS BLANK, (4) CAT 6CABLESSUBSCRIPT DENOTES NUMBER OF ACTIVEPORTSCADCESIICSIVRXSECURITY AND DOOR ACCESS SCHEDULESYMBOLDESCRIPTIONNOTESADA DOOR PUSHBUTTONPROVIDE ROUGH IN WITH CONNECTION TODOOR MOTOR. PROVIDE (1)1/2"C WITH CONTROLCABLING BETWEEN DOOR MOTOR ANDPUSHBUTTON. VERIFY LOCATIONS ANDCONNECTION REQUIREMENTS WITH EQUIPMENTPROVIDER. COORDINATE EQUIPMENTCONNECTIONS WITH ACCESS CONTROL SYSTEM.CARD ACCESS, PROXIMITY READER (ROUGH-INONLY)PROVIDE 4" SQUARE BACKBOX WITH 1"C ROUTEDTO NEAREST ACCESSIBLE CEILING SPACE.DOOR POSITION INDICATOR SWITCH (DPIS). PROVIDED WITH DOOR HARDWARE. ROUGH-INAND 1/2"C FROM DOOR FRAME TO CEILING BYDIVISION 26.ELECTRIC DOOR HARDWAREELECTRICAL LOCKING DEVICE AND POWERSUPPLY BY HARDWARE PROVIDER. PROVIDE120V POWER, ROUGH-IN, AND PATHWAY BYDIVISION 26.TWO-WAY COMMUNICATION / AREA-OF-REFUGECALL BOXAREA OF REFUGE TWO WAY COMMUNICATIONSYSTEM VOIP CALL STATION (FLUSH MOUNTWALL BOX). MOUNT AT +44" UNLESS OTHERWISENOTED. BASIS OF DESIGN: #RATH 2100-958NSIPOR APPROVED EQUAL. PROVIDE CAT6 CABLEROUTED BACK TO COMMAND STATION ATRECEPTION DESK ON FIRST FLOOR. PROVIDESIGNAGE AS REQUIRED BY IBC 1007.TWO-WAY COMMUNICATION / AREA-OF-REFUGECOMMAND STATIONAREA OF REFUGE TWO WAY COMMUNICATIONSYSTEM VOIP COMMAND STATION (DESK-PHONESTYLE). DEVICE SHALL BE INSTALLED ATRECEPTION DESK; FIELD COORDINATE EXACTROUGH-IN LOCATION WITH CASEWORKPROVIDER. BASIS OF DESIGN: RATH #2500-10NCVOR APPROVED EQUAL. PROVIDE CAT6 CABLEROUTED BACK TO PBX ROOM FOR VOIPCONNECTION TO NETWORK. PROVIDE SIGNAGEAS REQUIRED BY IBC 1007. COORDINATE WITHOWNER SELECTED SPECIAL SYSTEMS VENDORSFOR CONNECTION TO SECURITY AND TELECOMSYSTEMS AS REQUIRED. PROVIDE UPS BACKUPPOWER SUPPLY. BASIS OF DESIGN: RATH#RP7700104 OR APPROVED EQUAL.VESTIBULE INTERCOM STATIONVESTIBULE PUSHBUTTON INTERCOM SYSTEM.PROVIDE TWO-WAY COMMINUCATION DEVICEBETWEEN VESTIBULE AND FRONT DESK. DEVICEAT FRONT DESK SHALL BE INTEGRATED WITHSECURITY SYSTEM TO ALLOW FOR OPERATIONOF INTERIOR VESTIBULE DOOR AFTER HOURS.COORDINATE WITH OWNER FOR EXACT SYSTEMREQUIREMENTS.REQUEST TO EXIT1HHJSPECIAL BOX & RACEWAY SCHEDULESYMBOLDESCRIPTIONPRODUCTNOTESFLOOR BOX (5-GANG) LEGRAND #EFB45S (ORAPPROVED EQUAL)5-GANG RECESSED FLOOR BOX. INSTALL INFINISHED FLOOR. PROVIDE EVOLUTION SERIESSURFACE STYLE COVER AND BARRIER BETWEENPOWER AND DATA. PROVIDE RECEPTACLEDEVICES AS SHOWN ON PLANS. PROVIDEBRANCH CIRCUITING AS REQUIRED FOR POWERDEVICES SHOWN. IN ADDITION TO DEVICESSHOWN, PROVIDE (1)1"C FROM FLOOR BOXROUTED TO NEAREST ACCESSIBLE CEILINGSPACE. SEE ARCHITECTURAL PLANS FOR FLOORFINISHES AND PROVIDE ALL ACCESSORIESREQUIRED FOR INSTALLATION IN SURROUNDINGFLOOR.IN-GRADE HAND HOLE QUAZITE#PG1118DG12IN-GRADE, TIER 15, EXTERIOR-RATED, POLYMERCONCRETE BOX WITH POLYMER CONCRETE LID,BOTTOM, AND GASKETS, MOUNTED FLUSH WITHFINAL GRADE. SEE SITE DETAILS. PROVIDEBOLTED COVER #PG1118HA00## SERIES, LABELSHALL DESCRIBE INSTALLED SYSTEM, REPLACE'##' WITH:12 - COMMUNICATIONS84 - POWER29 - LIGHTING36 - SECURITYJUNCTION BOX-REQUIREMENTS AS NOTED ON PLANS.SFAAFACPFACPSBRFSHMS/CSTSFIRE ALARM SCHEDULESYMBOLDESCRIPTIONNOTEDUCT MOUNTED SMOKE DETECTORFIRE ALARM ANNUNCIATORFIRE ALARM CONTROL PANELFIRE ALARM CONTROL SUB PANELSPRINKLER ALARM BELLINTERFACE RELAYVISUAL SIGNALMOUNT AT +86" AFF TO CENTER OF DEVICE,UNLESS OTHERWISE NOTED.SPRINKLER FLOW SWITCHHEAT DETECTORHORN/STROBEMOUNT AT +86" AFF TO CENTER OF DEVICE,UNLESS OTHERWISE NOTED.MAGNETIC DOOR HOLDERMAKE CONNECTION TO MAGNETIC DOORHOLDER. DOORS TO BE HELD OPEN DURINGNORMAL OPERATION AND SHALL CLOSE UPONACTIVATION OF THE FIRE ALARM.MANUAL PULL STATIONMOUNT AT +44" AFF TO BOTTOM OF DEVICE,UNLESS OTHERWISE NOTED.COMBINATION SMOKE / CARBON MONOXIDEDETECTORSTAND-ALONE SMOKE / CARBON MONOXIDEDETECTION AND ALARM DEVICE. MOUNT WALLMOUNTED DEVICES AT +86" AFF.SMOKE DETECTORADDRESSABLE, FIRE ALARM SYSTEM INITIATIONDEVICE.TAMPER SWITCHRECEPTACLE SCHEDULESYMBOLDESCRIPTIONNOTESDUPLEX RECEPTACLENEMA 5-20RDUPLEX RECEPTACLE - CONTROLLEDNEMA 5-20R; WIRE DOWNSTREAM OFRECEPTACLE CONTROL MODULE (RCM).PROVIDE INDUSTRY STANDARD LABEL/ICONINDICATING CONTROLLED RECEPTACLE PERNEC SECTION 406.3(E).DUPLEX RECEPTACLE - GFCINEMA 5-20R, GFCIDUPLEX RECEPTACLE - GFCI/CONTROLLED NEMA 5-20R, GFCI; WIRE DOWNSTREAM OFRECEPTACLE CONTROL MODULE (RCM).PROVIDE INDUSTRY STANDARD LABEL/ICONINDICATING CONTROLLED RECEPTACLE PERNEC SECTION 406.3(E).HARDWIRED CONNECTIONCONNECTION REQUIREMENTS AS NOTED ONPLANSQUAD RECEPTACLENEMA 5-20RQUAD RECEPTACLE - CONTROLLEDNEMA 5-20R; WIRE SUCH THAT ONE DEVICE ISCONTROLLED BY RECEPTACLE CONTROLMODULE (RCM) AND ONE DEVICE ISUNSWITCHED. ON DEVICE THAT IS CONTROLLED,PROVIDE INDUSTRY STANDARD LABEL/ICONINDICATING CONTROLLED RECEPTACLE PERNEC SECTION 406.3(E).SUBSCRIPT NOTES:A: ABOVE COUNTERUSB: PROVIDE RECEPTACLE DEVICES WITH (1) USB-A AND (1) USB-C CHARGING PORTS32 MERCHANT STREET, SUITE 208HONOLULU, HI 96813808-352-5299OWNER:HOMEWOOD SUITES by HILTON
SPOKANE VALLEY, WA
13515 E. Carlisle Avenue
Spokane Valley, WA 99216FSC PROJECT NO. 21012PERMITDOCUMENTSMay 31, 2024GL8 MirabeauPoint, LLCTMK:PID: 45101.0401 10909 E. Pierce LaneSpokane, WA 99206(509) 919-0901Revision ScheduleNumber Description Date5915 S REGAL STREETSUITE 201SPOKANE, WA 99223PH: 509.473.9218Kelly@kwrllc.comwww.kwrllc.com5/30/2024 12:48:51 PMSTATE OF WASHINGTONREGISTERED PROFESSIONAL ENG
INEER48350 KELLY A
N
DREW WATERMAN05.31.24ELECTRICALSYMBOLS ANDABBREVIATIONSE-0011E-701SHEET INDEXABBREVIATIONSE-001 ELECTRICAL SYMBOLS AND ABBREVIATIONSE-002 EQUIPMENT SCHEDULESE-003 EQUIPMENT SCHEDULESE-004 LUMINAIRE SCHEDULESE-005 LUMINAIRE SCHEDULESE-101 ELECTRICAL SITE PLANE-102 ELECTRICAL SITE DETAILSE-103 ELECTRICAL SITE DETAILSE-104 STORAGE SHED ENLARGED ELECTRICAL PLANE-201A FIRST FLOOR LIGHTING PLAN - AREA AE-201B FIRST FLOOR LIGHTING PLAN - AREA BE-202A SECOND FLOOR LIGHTING PLAN - AREA AE-202B SECOND FLOOR LIGHTING PLAN - AREA BE-203A THIRD FLOOR LIGHTING PLAN - AREA AE-203B THIRD FLOOR LIGHTING PLAN - AREA BE-204A FOURTH FLOOR LIGHTING PLAN - AREA AE-204B FOURTH FLOOR LIGHTING PLAN - AREA BE-205A FIFTH FLOOR LIGHTING PLAN - AREA AE-205B FIFTH FLOOR LIGHTING PLAN - AREA BE-301A FIRST FLOOR ELECTRICAL PLAN - AREA AE-301B FIRST FLOOR ELECTRICAL PLAN - AREA BE-302A SECOND FLOOR ELECTRICAL PLAN - AREA AE-302B SECOND FLOOR ELECTRICAL PLAN - AREA BE-303A THIRD FLOOR ELECTRICAL PLAN - AREA AE-303B THIRD FLOOR ELECTRICAL PLAN - AREA BE-304A FOURTH FLOOR ELECTRICAL PLAN - AREA AE-304B FOURTH FLOOR ELECTRICAL PLAN - AREA BE-305A FIFTH FLOOR ELECTRICAL PLAN - AREA AE-305B FIFTH FLOOR ELECTRICAL PLAN - AREA BE-306 OVERALL ELECTRICAL ROOF PLANE-501 ENLARGED ELECTRICAL PLANSE-502 ENLARGED ELECTRICAL PLANSE-503 ENLARGED ELECTRICAL PLANSE-504 ENLARGED POOL PHOTOMETRIC PLANE-601 POWER ONE-LINE DIAGRAME-602 POWER ONE-LINE DIAGRAME-603 PANEL SCHEDULESE-604 PANEL SCHEDULESE-605 PANEL SCHEDULESE-606 PANEL SCHEDULESE-607 PANEL SCHEDULESE-608 PANEL SCHEDULESE-609 PANEL SCHEDULESE-610 PANEL SCHEDULESE-611 PANEL SCHEDULESE-612 PANEL SCHEDULESE-701 ELECTRICAL DETAILSE-702 ELECTRICAL DETAILSGENERAL SYMBOLSAAMPEREADA AMERICANS WITH DISABILITIES ACTAFF ABOVE FINISHED FLOORAFG ABOVE FINISHED GRADEAHJ AUTHORITY HAVING JURISDICTIONAL ALUMINUMA/V AUDIO/VIDEOCB CIRCUIT BREAKERCCONDUITCO CONDUIT ONLYCU COPPERDDC DIRECT DIGITAL CONTROL SYSTEMDISC DISCONNECTDIV DIVISIONEGC EQUIPMENT GROUNDING CONDUCTOREEXISTINGEM EMERGENCYELEC ELECTRIC(AL)EXT EXTERIORFA FIRE ALARMFSD FIRE/SMOKE DAMPERGEC GROUNDING ELECTRODE CONDUCTORGND GROUNDGFCI GROUND FAULT CIRCUIT INTERRUPTERHHORIZONTALHP HORSEPOWERISP INTERNET SERVICE PROVIDERKW KILOWATT(S)kVA KILOVOLT-AMPERE(S)LM LUMEN(S)LPG LIQUEFIED PETROLEUM GASLPW LUMENS PER WATTLTG LIGHT(S), LIGHTINGMDF MAIN DISTRIBUTION FRAMEMTD MOUNTEDMVOLT MULTI-VOLTNEC NATIONAL ELECTRICAL CODENIC NOT IN CONTRACTNTS NOT TO SCALEOCP OVER-CURRENT PROTECTION / PROTECTIVE DEVICEOFCI OWNER FURNISHED, CONTRACTOR INSTALLEDOFOI OWNER FURNISHED, OWNER INSTALLEDOS OCCUPANCY SENSORPVC POLYVINYL CHLORIDEPC PHOTOCELLSPD SURGE PROTECTIVE DEVICESPEC(S) SPECIFICATION(S)SS STAINLESS STEELSUSE SUITABLE FOR USE AS SERVICE EQUIPMENTSW SWITCHTYP. TYPICALUG/E UNDERGROUND ELECTRICALUG/T UNDERGROUND TELECOMUON UNLESS OTHERWISE NOTEDWP WEATHERPROOFW WATT(S)XFMR TRANSFORMERDETAIL REFERENCE CALLOUTDETAIL NUMBERSHEET NUMBER1HG1-12CIRCUIT CALLOUTPANEL NAMECIRCUIT NUMBERFLAG NOTE INDICATORFLAG NOTE REFERENCE NUMBERSEE CORRESPONDING FLAG NOTEDESCRIPTION ON SHEETGROUNDING ELECTRODEEQUIPMENT DISCONNECT SWITCHEQUIPMENT CONNECTION / CALLOUTEQUIPMENT CALLOUTEQUIPMENT CONNECTIONHG1ELECTRICAL PANELBOARDPANEL CALLOUTMDPMAIN DISTRIBUTIONEQUIPMENT CALLOUTELECTRICAL DISTRIBUTION EQUIPMENTX1TRANSFORMER CALLOUTDRY-TYPE TRANSFORMER*ALL BRANCH CIRCUITS SHALL BE 2#12, #12GUNLESS OTHERWISE NOTEDONE-LINE CIRCUIT BREAKERONE-LINE FUSED DISCONNECT/SWITCHONE-LINE PREPARED SPACECONDUIT RISER, STUB UP/DOWN20/1250 AFOCP / POLES(I.E. 20A, 1-POLE)FRAME SIZE(I.E. 250 AMP-FRAME)VERTICAL RACEWAY /TRANSITION30/3OCP / POLES(I.E. 30A, 3-POLE)GONE-LINE GENERATOR SETNO / NC CONTACTSGENERAL NOTES1. "GENERAL NOTES" ON THIS SHEET APPLY TO ALL DRAWINGS."GENERAL NOTES" ON EACH SHEET APPLY TO ALL OF THE SHEETSON WHICH THEY OCCUR. "FLAG NOTES" APPLY ONLY WHERECALLED OUT.2. ALL EQUIPMENT SHOWN IN BOLD IS TO BE PROVIDED BYCONTRACTOR UNLESS OTHERWISE NOTED.3. CONTRACTOR SHALL PROVIDE CONDUIT AND WIRE FROM ALLCONTROL DEVICES TO LUMINAIRES FOR CONTROL OF LUMINAIRESSHOWN.4. LUMINAIRES SHOWN ON DRAWINGS FOR QUANTITY AND CIRCUITINGONLY. SEE ARCHITECTURAL REFLECTED CEILING PLANS FOR EXACTLOCATIONS.5. ALL FEEDERS AND BRANCH CIRCUITS SHALL CONTAIN ANEQUIPMENT GROUND CONDUCTOR SIZED PER NEC TABLE 250.122.FEEDERS AND BRANCH CIRCUITS OVER 100A ARE BASED ONCOPPER (CU) PER NEC TABLE 310.15(B)(16), USING 75 DEGREEAMPACITIES. FEEDERS 100A OR LESS USE 60 DEGREE C COLUMN.6. BRANCH CIRCUIT CONDUCTORS, IF NOT OTHERWISE IDENTIFIED,SHALL BE A MINIMUM #12 AWG FOR RUNS 70 FEET OR LESS, AND AMINIMUM OF #10 AWG FOR RUNS GREATER THAN 70 FEET. QUANTITYAND SIZE SHALL BE "AS REQUIRED" TO SERVE AND CONTROLDEVICE(S) OR EQUIPMENT WITH A MAXIMUM VOLTAGE DROP OFTHREE PERCENT. BRANCH CIRCUIT CONDUITS SHALL NOT CONTAINMORE THAN THREE PHASE CONDUCTORS.7. MINIMUM CONDUIT IN EXTERIOR AND UNDERGROUND LOCATIONSSHALL BE 1". MINIMUM CONDUIT FOR INTERIOR BRANCH CIRCUITSSHALL BE 3/4". CONDUITS FROM LUMINAIRES TO LOCAL USERCONTROL DEVICES (SWITCHES, OCCUPANCY SENSORS, ETC.) MAYBE 1/2" OR AS INDICATED IN SPECIFICATIONS.8. WIRING FOR EMERGENCY LIGHTING CIRCUITS OR OTHEREMERGENCY EQUIPMENT SHALL BE KEPT ENTIRELY INDEPENDENTOF ALL OTHER WIRING AND EQUIPMENT, AND SHALL MEET ALLREQUIREMENTS OF NEC SECTION NEC 700.10.9. PROVIDE DEDICATED NEUTRAL CONDUCTORS FOR ALL BRANCHCIRCUITS.10. ALL 120V DUPLEX AND QUAD RECEPTACLES SHALL BE 20A RATEDAND LISTED TAMPER-RESISTANT TYPE.11. RECEPTACLE DEVICES INSTALLED IN WET LOCATIONS OR INDICATEDWITH A 'WP' SUBSCRIPT SHALL BE LISTED AS WEATHER RESISTANTTYPE, INSTALLED WITH A WEATHERPROOF WHILE IN USE COVERWITH A HOOD THAT IS LISTED AND IDENTIFIED AS "EXTRA DUTY", INCONFORMANCE WITH NEC 406.9(B)(1).CONDUIT STUB WITHBUSHING OR CAPT3T1T1T2AAT4abaEXITT2abaT4T1T3VARIES
BOTTOM OF BOX TO BE MOUNTED2" ABOVE BACKSPLASH80"
86"
18"
46"
18"
46"
18"FLOORCENTERLINE OF BOXES @DIFFERENT HEIGHTS SHALLALIGN VERTICALLY (TYP).ADJACENT PANELBOARDSSHALL HAVE MATCHINGHEIGHT DIMENSIONSELEVATIONPLANNOTES1. THIS IS A TYPICAL DETAIL, DEVICES SHOWN HERE MAY NOT BEINCLUDED IN THE PROJECT.2. A = 2" TO BOTTOM OF BOX, ABOVE COUNTER TOP ORBACKSPLASH3. MOUNTING HEIGHTS ON DRAWINGS ARE TO CENTER OF BOX.2CENTER BETWEEN TOP OF DOOR FRAMEAND CEILING (9'-0" OR LESS) OR 6" ABOVEFRAME FOR CEILING HIGHER THAN 9'-0"86"11T1T246"T2AAATSCALE:1TYPICAL MOUNTING HEIGHTS - GENERIC DETAILNOT TO SCALEEF-1OUT
IN
MECHANICAL EQUIPMENT SCHEDULECALLOUT EQUIPMENT DESCRIPTION VOLTAGELOAD TYPE OCP AMPS CONDUIT & WIRE CONNECTIONTYPEDISCONNECTDESCRIPTIONDISC NEMARATINGDISC BY CIRCUITNOTESAHU-01 AIR HANDLING UNIT480V 3P 4WMOTOR: 15.8 KVA 30/3 19 3/4"C,4#10,#10G HARDWIRED 3P30A, 30A FUSESNEMA 1 DIV 26 H1M-1,3,5BCU-1 BRANCH CONTROLLER 208/120V 2P 3W MOTOR: 0.17 KVA 15/2 0.83 3/4"C,3#10,#10G HARDWIRED 2-POLE MOTOR RATEDTOGGLE SWITCHNEMA 1 DIV 26 L12-9,11BCU-2 BRANCH CONTROLLER 208/120V 2P 3W MOTOR: 0.33 KVA 15/2 1.57 3/4"C,3#10,#10G HARDWIRED 2-POLE MOTOR RATEDTOGGLE SWITCHNEMA 1 DIV 26 L31-1,3CU-01A OUTDOOR CONDENSINGUNIT480V 3P 4WMOTOR: 2.49 KVA 15/3 3 3/4"C,4#12,#12G HARDWIRED 3P30A, 15A FUSESNEMA 3R DIV 26 H1M-2,4,6CU-01B OUTDOOR CONDENSINGUNIT480V 3P 4WMOTOR: 2.49 KVA 15/3 3 3/4"C,4#12,#12G HARDWIRED 3P30A, 15A FUSESNEMA 3R DIV 26 H1M-8,10,12CU-02A OUTDOOR CONDENSINGUNIT480V 3P 4WMOTOR: 29.1 KVA 50/3 35 1"C,4#6,#10G HARDWIRED 3P60A, 50A FUSESNEMA 3R DIV 26 H5M-1,3,5CU-02B OUTDOOR CONDENSINGUNIT480V 3P 4WMOTOR: 29.1 KVA 50/3 35 1"C,4#6,#10G HARDWIRED 3P60A, 50A FUSESNEMA 3R DIV 26 H5M-7,9,11CU-03A OUTDOOR CONDENSINGUNIT480V 3P 4WMOTOR: 20.78 KVA 40/3 25 3/4"C,4#8,#10G HARDWIRED 3P60A, 40A FUSESNEMA 3R DIV 26 H5M-2,4,6CU-03B OUTDOOR CONDENSINGUNIT480V 3P 4WMOTOR: 20.78 KVA 40/3 25 3/4"C,4#8,#10G HARDWIRED 3P60A, 40A FUSESNEMA 3R DIV 26 H5M-8,10,12CU-04 OUTDOOR CONDENSINGUNIT208V 3P 4WMOTOR: 3.96 KVA 25/3 11 3/4"C,4#12,#12G HARDWIRED 3P30A, 25A FUSESNEMA 3R DIV 26 L51-5,7,9CU-05 OUTDOOR CONDENSINGUNIT208V 3P 4WMOTOR: 3.96 KVA 25/3 11 3/4"C,4#10,#10G HARDWIRED 3P30A, 25A FUSESNEMA 3R DIV 26 L51-11,13,15DH-01 DUCT HEATER120V 1P 2WHEATING: 0.24 KVA 20/1 2 3/4"C,2#12,#12G HARDWIRED LOCKABLE CIRCUITBREAKERN/ADIV 26 L12-6 PROVIDE LOCKABLE CIRCUITBREAKER.DHWP-1 DOMESTIC HOT WATERPUMP120V 1P 2WMOTOR: 0.58 KVA20/1 4.8 3/4"C,2#12,#12G HARDWIRED MOTOR RATEDTOGGLE SWITCHNEMA 1 DIV 26 L12-10DHWP-2 DOMESTIC HOT WATERPUMP120V 1P 2WMOTOR: 0.12 KVA20/1 1 3/4"C,2#12,#12G HARDWIRED MOTOR RATEDTOGGLE SWITCHNEMA 1 DIV 26 L12-12EF-01 EXHAUST FAN208/120V 2P 3W MOTOR: 2 HP20/2 13.85 3/4"C,3#10,#10G HARDWIRED 2-POLE 30A MOTORRATED TOGGLESWITCHNEMA 3R DIV 26 L21-8,10 PROVIDE 120V CONNECTIONFOR ASSOCIATED DAMPERACTUATOR.EF-02 EXHAUST FAN120V 1P 2WMOTOR: 1/10 HP20/1 3.5 3/4"C,2#10,#10G HARDWIRED MOTOR RATEDTOGGLE SWITCHNEMA 3R DIV 26 L21-12 PROVIDE 120V CONNECTIONFOR ASSOCIATED DAMPERACTUATOR.EF-03 KITCHEN HOOD EXHAUSTFAN208/120V 2P 3W KITCHEN: 3/4 HP15/2 7.96 3/4"C,3#12,#12G HARDWIRED 2P30A, 15A FUSESNEMA 3R DIV 26 L1KA-38,40 ROUTE BRANCH CIRCUITTHROUGH KITCHEN HOODANSUL PANEL. SEE HOOD SHOPDRAWINGS AND COORDINATEWITH HOOD EQUIPMENTPROVIDER FOR EXACTREQUIREMENTS. FIELD VERIFYCONNECTION LOCATION ANDDISCONNECT MOUNTINGLCOATION.EH-11 ELECTRIC HEATER120V 1P 2WHEATING: 1 KVA20/1 8.33 3/4"C,2#12,#12G HARDWIRED LOCKABLE CIRCUITBREAKERN/ADIV 26 L12-14 PROVIDE LOCKABLE CIRCUITBREAKER.EH-12 ELECTRIC HEATER120V 1P 2WHEATING: 1 KVA20/1 8.33 3/4"C,2#12,#12G HARDWIRED LOCKABLE CIRCUITBREAKERN/ADIV 26 L14A-5 PROVIDE LOCKABLE CIRCUITBREAKER.EH-21 ELECTRIC HEATER120V 1P 2WHEATING: 1 KVA20/1 8.33 3/4"C,2#12,#12G HARDWIRED LOCKABLE CIRCUITBREAKERN/ADIV 26 L21-2 PROVIDE LOCKABLE CIRCUITBREAKER.EH-22 ELECTRIC HEATER120V 1P 2WHEATING: 1 KVA20/1 8.33 3/4"C,2#10,#10G HARDWIRED LOCKABLE CIRCUITBREAKERN/ADIV 26 L21-4 PROVIDE LOCKABLE CIRCUITBREAKER.EH-31 ELECTRIC HEATER120V 1P 2WHEATING: 1 KVA20/1 8.33 3/4"C,2#12,#12G HARDWIRED LOCKABLE CIRCUITBREAKERN/ADIV 26 L31-2 PROVIDE LOCKABLE CIRCUITBREAKER.EH-32 ELECTRIC HEATER120V 1P 2WHEATING: 1 KVA20/1 8.33 3/4"C,2#10,#10G HARDWIRED LOCKABLE CIRCUITBREAKERN/ADIV 26 L31-4 PROVIDE LOCKABLE CIRCUITBREAKER.EH-41 ELECTRIC HEATER120V 1P 2WHEATING: 1 KVA20/1 8.33 3/4"C,2#12,#12G HARDWIRED LOCKABLE CIRCUITBREAKERN/ADIV 26 L41-2 PROVIDE LOCKABLE CIRCUITBREAKER.EH-42 ELECTRIC HEATER120V 1P 2WHEATING: 1 KVA20/1 8.33 3/4"C,2#10,#10G HARDWIRED LOCKABLE CIRCUITBREAKERN/ADIV 26 L41-4 PROVIDE LOCKABLE CIRCUITBREAKER.EH-51 ELECTRIC HEATER120V 1P 2WHEATING: 1 KVA20/1 8.33 3/4"C,2#12,#12G HARDWIRED LOCKABLE CIRCUITBREAKERN/ADIV 26 L51-2 PROVIDE LOCKABLE CIRCUITBREAKER.EH-52 ELECTRIC HEATER120V 1P 2WHEATING: 1 KVA20/1 8.33 3/4"C,2#10,#10G HARDWIRED LOCKABLE CIRCUITBREAKERN/ADIV 26 L51-4 PROVIDE LOCKABLE CIRCUITBREAKER.ERV-01 ENERGY RECOVERYVENTILATOR480V 3P 4WMOTOR: 33.26 KVA 60/3 401"C,4#6,#8G HARDWIRED 3P60A, 60A FUSESNEMA 3R DIV 26 H5M-13,15,17FCU-211 INDOOR FAN COIL208/120V 2P 3W MOTOR: 0.88 KVA 15/2 4.25 3/4"C,3#10,#10G HARDWIRED 2-POLE MOTOR RATEDTOGGLE SWITCHNEMA 1 DIV 26 L12-9,11FCU-212 INDOOR FAN COIL208/120V 2P 3W MOTOR: 0.6 KVA15/2 2.88 3/4"C,3#10,#10G HARDWIRED 2-POLE MOTOR RATEDTOGGLE SWITCHNEMA 1 DIV 26 L12-9,11FCU-213 INDOOR FAN COIL208/120V 2P 3W MOTOR: 0.91 KVA 15/2 4.38 3/4"C,3#10,#10G HARDWIRED 2-POLE MOTOR RATEDTOGGLE SWITCHNEMA 1 DIV 26 L12-16,18FCU-214 INDOOR FAN COIL208/120V 2P 3W MOTOR: 0.88 KVA 15/2 4.25 3/4"C,3#10,#10G HARDWIRED 2-POLE MOTOR RATEDTOGGLE SWITCHNEMA 1 DIV 26 L12-16,18FCU-215 INDOOR FAN COIL208/120V 2P 3W MOTOR: 1.71 KVA 15/2 8.2 3/4"C,3#10,#10G HARDWIRED 2-POLE MOTOR RATEDTOGGLE SWITCHNEMA 1 DIV 26 L14A-1,3FCU-216 INDOOR FAN COIL208/120V 2P 3W MOTOR: 0.44 KVA 15/2 2.13 3/4"C,3#10,#10G HARDWIRED 2-POLE MOTOR RATEDTOGGLE SWITCHNEMA 1 DIV 26 L14A-1,3FCU-217 INDOOR FAN COIL208/120V 2P 3W MOTOR: 0.6 KVA15/2 2.88 3/4"C,3#10,#10G HARDWIRED 2-POLE MOTOR RATEDTOGGLE SWITCHNEMA 1 DIV 26 L14A-1,3FCU-311 INDOOR FAN COIL208/120V 2P 3W MOTOR: 0.05 KVA 15/2 0.24 3/4"C,3#10,#10G HARDWIRED 2-POLE MOTOR RATEDTOGGLE SWITCHNEMA 1 DIV 26 L12-16,18FCU-321 INDOOR FAN COIL208/120V 2P 3W MOTOR: 0.05 KVA 15/2 0.24 3/4"C,3#10,#10G HARDWIRED 2-POLE MOTOR RATEDTOGGLE SWITCHNEMA 1 DIV 26 L21-1,3FCU-322 INDOOR FAN COIL208/120V 2P 3W MOTOR: 0.05 KVA 15/2 0.24 3/4"C,3#10,#10G HARDWIRED 2-POLE MOTOR RATEDTOGGLE SWITCHNEMA 1 DIV 26 L21-1,3FCU-323 INDOOR FAN COIL208/120V 2P 3W MOTOR: 0.06 KVA 15/2 0.29 3/4"C,3#10,#10G HARDWIRED 2-POLE MOTOR RATEDTOGGLE SWITCHNEMA 1 DIV 26 L21-1,3FCU-324 INDOOR FAN COIL208/120V 2P 3W MOTOR: 0.05 KVA 15/2 0.24 3/4"C,3#10,#10G HARDWIRED 2-POLE MOTOR RATEDTOGGLE SWITCHNEMA 1 DIV 26 L21-1,3FCU-325 INDOOR FAN COIL208/120V 2P 3W MOTOR: 0.05 KVA 15/2 0.24 3/4"C,3#10,#10G HARDWIRED 2-POLE MOTOR RATEDTOGGLE SWITCHNEMA 1 DIV 26 L21-1,3FCU-326 INDOOR FAN COIL208/120V 2P 3W MOTOR: 0.36 KVA 15/2 1.75 3/4"C,3#10,#10G HARDWIRED 2-POLE MOTOR RATEDTOGGLE SWITCHNEMA 1 DIV 26 L21-1,3FCU-331 INDOOR FAN COIL208/120V 2P 3W MOTOR: 0.05 KVA 15/2 0.24 3/4"C,3#10,#10G HARDWIRED 2-POLE MOTOR RATEDTOGGLE SWITCHNEMA 1 DIV 26 L31-1,3FCU-332 INDOOR FAN COIL208/120V 2P 3W MOTOR: 0.06 KVA 15/2 0.29 3/4"C,3#10,#10G HARDWIRED 2-POLE MOTOR RATEDTOGGLE SWITCHNEMA 1 DIV 26 L31-1,3FCU-333 INDOOR FAN COIL208/120V 2P 3W MOTOR: 0.05 KVA 15/2 0.24 3/4"C,3#10,#10G HARDWIRED 2-POLE MOTOR RATEDTOGGLE SWITCHNEMA 1 DIV 26 L31-1,3FCU-334 INDOOR FAN COIL208/120V 2P 3W MOTOR: 0.05 KVA 15/2 0.24 3/4"C,3#10,#10G HARDWIRED 2-POLE MOTOR RATEDTOGGLE SWITCHNEMA 1 DIV 26 L31-1,3FCU-335 INDOOR FAN COIL208/120V 2P 3W MOTOR: 0.36 KVA 15/2 1.75 3/4"C,3#10,#10G HARDWIRED 2-POLE MOTOR RATEDTOGGLE SWITCHNEMA 1 DIV 26 L31-1,3FCU-341 INDOOR FAN COIL208/120V 2P 3W MOTOR: 0.05 KVA 15/2 0.24 3/4"C,3#10,#10G HARDWIRED 2-POLE MOTOR RATEDTOGGLE SWITCHNEMA 1 DIV 26 L41-1,3FCU-342 INDOOR FAN COIL208/120V 2P 3W MOTOR: 0.06 KVA 15/2 0.29 3/4"C,3#10,#10G HARDWIRED 2-POLE MOTOR RATEDTOGGLE SWITCHNEMA 1 DIV 26 L41-1,3FCU-343 INDOOR FAN COIL208/120V 2P 3W MOTOR: 0.05 KVA 15/2 0.24 3/4"C,3#10,#10G HARDWIRED 2-POLE MOTOR RATEDTOGGLE SWITCHNEMA 1 DIV 26 L41-1,3FCU-344 INDOOR FAN COIL208/120V 2P 3W MOTOR: 0.05 KVA 15/2 0.24 3/4"C,3#10,#10G HARDWIRED 2-POLE MOTOR RATEDTOGGLE SWITCHNEMA 1 DIV 26 L41-1,3MECHANICAL EQUIPMENT SCHEDULE (CONT.)CALLOUT EQUIPMENT DESCRIPTION VOLTAGELOAD TYPE OCP AMPS CONDUIT & WIRE CONNECTIONTYPEDISCONNECTDESCRIPTIONDISC NEMARATINGDISC BY CIRCUITNOTESFCU-345 INDOOR FAN COIL208/120V 2P 3W MOTOR: 0.36 KVA 15/2 1.75 3/4"C,3#10,#10G HARDWIRED 2-POLE MOTOR RATEDTOGGLE SWITCHNEMA 1 DIV 26 L41-1,3FCU-351 INDOOR FAN COIL208/120V 2P 3W MOTOR: 0.05 KVA 15/2 0.24 3/4"C,3#10,#10G HARDWIRED 2-POLE MOTOR RATEDTOGGLE SWITCHNEMA 1 DIV 26 L51-1,3FCU-352 INDOOR FAN COIL208/120V 2P 3W MOTOR: 0.06 KVA 15/2 0.29 3/4"C,3#10,#10G HARDWIRED 2-POLE MOTOR RATEDTOGGLE SWITCHNEMA 1 DIV 26 L51-1,3FCU-353 INDOOR FAN COIL208/120V 2P 3W MOTOR: 0.05 KVA 15/2 0.24 3/4"C,3#10,#10G HARDWIRED 2-POLE MOTOR RATEDTOGGLE SWITCHNEMA 1 DIV 26 L51-1,3FCU-354 INDOOR FAN COIL208/120V 2P 3W MOTOR: 0.05 KVA 15/2 0.24 3/4"C,3#10,#10G HARDWIRED 2-POLE MOTOR RATEDTOGGLE SWITCHNEMA 1 DIV 26 L51-1,3FCU-355 INDOOR FAN COIL208/120V 2P 3W MOTOR: 0.36 KVA 15/2 1.75 3/4"C,3#10,#10G HARDWIRED 2-POLE MOTOR RATEDTOGGLE SWITCHNEMA 1 DIV 26 L51-1,3FCU-421 INDOOR FAN COIL208/120V 2P 3W MOTOR: 0.6 KVA15/2 2.88 3/4"C,3#10,#10G HARDWIRED 2-POLE MOTOR RATEDTOGGLE SWITCHNEMA 1 DIV 26 L21-1,3FCU-500 INDOOR FAN COIL208/120V 2P 3W MOTOR: 0.6 KVA15/2 2.88 3/4"C,3#10,#10G HARDWIRED 2-POLE MOTOR RATEDTOGGLE SWITCHNEMA 1 DIV 26 L51-1,3H-1 KITCHEN HOOD 1ELECTRICAL120V 1P 2WLIGHTING: 1.8 KVA 20/1 15 3/4"C,2#12,#12G HARDWIRED LOCKABLE CIRCUITBREAKERN/ADIV 26 L1KA-28 PROVIDE 20A HOOD MOUNTEDSWITCH TO CONTROL HOODLIGHTS. COORDINATE WITHEQUIPMENT PROVIDER FORALL CONTROL WIRING ASREQUIRED.H-1.1 KITCHEN HOOD FIRESUPRESSION SYSTEM(ANSUL PANEL)120V 1P 2WNONCONTINUOUS: 0.5KVA20/1 4.17 3/4"C,2#12,#12G HARDWIRED LOCKABLE CIRCUITBREAKERN/ADIV 26 L1KA-30 PROVIDE LOCKABLE CIRCUITBREAKER WITH RED HANDLE.MAU-01 MAKEUP AIR UNIT208V 3P 4WKITCHEN: 1.12 KVA 15/3 3.1 3/4"C,4#12,#12G HARDWIRED 3P30A, 15A FUSESNEMA 1 DIV 26 L1KA-32,34,36 ROUTE BRANCH CIRCUITTHROUGH KITCHEN HOODANSUL PANEL. SEE HOOD SHOPDRAWINGS AND COORDINATEWITH HOOD EQUIPMENTPROVIDER FOR EXACTREQUIREMENTS. FIELDCOORDINATE CONNECTLOCATION AND DISCONNECTMOUNTING LOCATION.SP-1 SUMP PUMP120V 1P 2WMOTOR: 1/2 HP20/1 9.8 3/4"C,2#10,#10G HARDWIRED MOTOR RATEDTOGGLE SWITCHNEMA 4X DIV 26 ELEV-2SP-2 SUMP PUMP120V 1P 2WMOTOR: 1/2 HP20/1 9.8 3/4"C,2#10,#10G HARDWIRED MOTOR RATEDTOGGLE SWITCHNEMA 4X DIV 26 ELEV-4UH-01 ELECTRIC UNIT HEATER 208V 2P 2WMOTOR: 5.64 KVA 35/2 27.1 3/4"C,2#8,#10G HARDWIRED LOCKABLE CIRCUITBREAKERN/ADIV 26 L12-2,4 PROVIDE LOCKABLE CIRCUITBREAKER.UH-02 ELECTRIC UNIT HEATER 208V 2P 2WMOTOR: 3.74 KVA 30/2 18 3/4"C,2#10,#10G HARDWIRED LOCKABLE CIRCUITBREAKERN/ADIV 26 LSS-5,7 PROVIDE LOCKABLE CIRCUITBREAKER.WH-1 GAS WATER HEATER 120V 1P 2WHEATING: 0.6 KVA 20/1 5 3/4"C,2#10,#10G HARDWIRED LOCKABLE CIRCUITBREAKERN/ADIV 26 L12-1 PROVIDE LOCKABLE CIRCUITBREAKER.WH-2 GAS WATER HEATER 120V 1P 2WHEATING: 0.6 KVA 20/1 5 3/4"C,2#10,#10G HARDWIRED LOCKABLE CIRCUITBREAKERN/ADIV 26 L12-3 PROVIDE LOCKABLE CIRCUITBREAKER.WH-3 GAS WATER HEATER 120V 1P 2WHEATING: 0.6 KVA 20/1 5 3/4"C,2#10,#10G HARDWIRED LOCKABLE CIRCUITBREAKERN/ADIV 26 L12-5 PROVIDE LOCKABLE CIRCUITBREAKER.WH-4 GAS WATER HEATER 120V 1P 2WHEATING: 0.6 KVA 20/1 5 3/4"C,2#10,#10G HARDWIRED LOCKABLE CIRCUITBREAKERN/ADIV 26 L12-7 PROVIDE LOCKABLE CIRCUITBREAKER.WS-01 WATER SOFTENER120V 1P 2WMOTOR: 1.8 KVA20/1 15 3/4"C,2#12,#12G RECEPTACLE NEMA 5-20RN/ADIV 26 L12-8EQUIPMENT SCHEDULECALLOUT EQUIPMENT DESCRIPTION VOLTAGELOAD TYPEOCP AMPS CONDUIT & WIRE CONNECTIONTYPEDISCONNECTDESCRIPTIONDISC NEMARATINGDISC BY CIRCUITNOTESCOPY-1 COPIER120V 1P 2WNONCONTINUOUS: 1.2 KVA 20/1 10 3/4"C,2#12,#12G RECEPTACLE NEMA 5-20RN/ADIV 26 L14A-6DF-1 DRINKINGFOUNTAIN/BOTTLE FILLER120V 1P 2WNONCONTINUOUS: 0.72 KVA 20/1 6 3/4"C,2#10,#10G RECEPTACLE NEMA 5-20RN/ADIV 26 L11-40 PROVIDE GFCI CIRCUITBREAKER WITH 6mA TRIP.DF-2 DRINKINGFOUNTAIN/BOTTLE FILLER120V 1P 2WNONCONTINUOUS: 0.72 KVA 20/1 6 3/4"C,2#10,#10G RECEPTACLE NEMA 5-20RN/ADIV 26 L14A-2 PROVIDE GFCI CIRCUITBREAKER WITH 6mA TRIP.DW-1 DISHWASHER120V 1P 2WKITCHEN: 1.2 KVA20/1 10 3/4"C,2#10,#10G RECEPTACLE NEMA 5-20RN/ADIV 26 L11-29 PROVIDE GFCI CIRCUITBREAKER WITH 6mA TRIP.FP-1 FLAG POLE120V 1P 2WLIGHTING: 0.01 KVA20/1 0.1 3/4"C,2#10,#10G HARDWIRED LOCKABLECIRCUITBREAKERN/ADIV 26 L12-17 ROUTE BRANCH CIRCUIT VIACONTROL MODULE, SHOWN ONSHEET E-301A, FOR TIMECLOCKCONTROL.FP-2 FLAG POLE120V 1P 2WLIGHTING: 0.01 KVA20/1 0.1 3/4"C,2#10,#10G HARDWIRED LOCKABLECIRCUITBREAKERN/ADIV 26 L12-17 SEE FP-1 FOR ADDITIONALADDITIONAL INFORMATION ONFLAG POLE LIGHTINGREQUIREMENTS.FP-3 FLAG POLE120V 1P 2WLIGHTING: 0.01 KVA20/1 0.1 3/4"C,2#10,#10G HARDWIRED LOCKABLECIRCUITBREAKERN/ADIV 26 L12-17 SEE FP-1 FOR ADDITIONALADDITIONAL INFORMATION ONFLAG POLE LIGHTINGREQUIREMENTS.ICE-1 ICE MACHINE120V 1P 2WMOTOR: 0.19 KVA20/1 1.6 3/4"C,2#10,#10G RECEPTACLE NEMA 5-20RN/ADIV 26 L11-38 PROVIDE GFCI CIRCUITBREAKER WITH 6mA TRIP.MW-1 MICROWAVE120V 1P 2WNONCONTINUOUS: 1 KVA20/1 8.33 3/4"C,2#10,#10G RECEPTACLE NEMA 5-20RN/ADIV 26 L11-31 PROVIDE GFCI CIRCUITBREAKER WITH 6mA TRIP.PRINT-1 COPIER120V 1P 2WNONCONTINUOUS: 0.6 KVA 20/1 5 3/4"C,2#10,#10G RECEPTACLE NEMA 5-20RN/ADIV 26 L14A-4REF-1 REFRIGERATOR120V 1P 2WNONCONTINUOUS: 0.8 KVA 20/1 6.67 3/4"C,2#10,#10G RECEPTACLE NEMA 5-20RN/ADIV 26 L11-27 PROVIDE GFCI CIRCUITBREAKER WITH 6mA TRIP.32 MERCHANT STREET, SUITE 208HONOLULU, HI 96813808-352-5299OWNER:HOMEWOOD SUITES by HILTON
SPOKANE VALLEY, WA
13515 E. Carlisle Avenue
Spokane Valley, WA 99216FSC PROJECT NO. 21012PERMITDOCUMENTSMay 31, 2024GL8 MirabeauPoint, LLCTMK:PID: 45101.0401 10909 E. Pierce LaneSpokane, WA 99206(509) 919-0901Revision ScheduleNumber Description Date5915 S REGAL STREETSUITE 201SPOKANE, WA 99223PH: 509.473.9218Kelly@kwrllc.comwww.kwrllc.com5/30/2024 12:48:56 PMSTATE OF WASHINGTONREGISTERED PROFESSIONAL ENG
INEER48350 KELLY A
N
DREW WATERMAN05.31.24EQUIPMENTSCHEDULESE-002
FITNESS EQUIPMENT SCHEDULECALLOUT EQUIPMENT DESCRIPTION VOLTAGELOAD TYPEOCP AMPS CONDUIT & WIRE CONNECTIONTYPEDISCONNECTDESCRIPTIONDISC NEMARATINGDISC BY CIRCUITNOTESBIKE-1 PELOTON BIKE120V 1P 2WMOTOR: 0.18 KVA20/1 1.5 3/4"C,2#10,#10G RECEPTACLE NEMA 5-20RN/ADIV 26 L11-36ELLIP-1 ELLIPTICAL120V 1P 2WMOTOR: 0.18 KVA20/1 1.5 3/4"C,2#10,#10G RECEPTACLE NEMA 5-20RN/ADIV 26 L11-36ELLIP-2 ELLIPTICAL120V 1P 2WMOTOR: 0.18 KVA20/1 1.5 3/4"C,2#10,#10G RECEPTACLE NEMA 5-20RN/ADIV 26 L11-36TREAD-1 TREADMILL120V 1P 2WMOTOR: 0.6 KVA20/1 5 3/4"C,2#10,#10G RECEPTACLE NEMA 5-20RN/ADIV 26 L11-33TREAD-2 TREADMILL120V 1P 2WMOTOR: 0.6 KVA20/1 5 3/4"C,2#10,#10G RECEPTACLE NEMA 5-20RN/ADIV 26 L11-35TREAD-3 TREADMILL120V 1P 2WMOTOR: 0.6 KVA20/1 5 3/4"C,2#10,#10G RECEPTACLE NEMA 5-20RN/ADIV 26 L11-37TREAD-4 TREADMILL120V 1P 2WMOTOR: 0.6 KVA20/1 5 3/4"C,2#10,#10G RECEPTACLE NEMA 5-20RN/ADIV 26 L11-39GUEST UNIT EQUIPMENT SCHEDULECALLOUT EQUIPMENT DESCRIPTION VOLTAGELOAD TYPEOCP AMPS CONDUIT & WIRE CONNECTIONTYPEDISCONNECTDESCRIPTIONDISC NEMARATINGDISC BYNOTESCOOK-2 GUEST UNIT INDUCTIONCOOKTOP, 2-BURNER208/120V 2P 3W NONCONTINUOUS: 3 KVA20/2 14.42 3/4"C,3#12,#12G HARDWIRED LOCKABLECIRCUITBREAKERN/ADIV 26 PROVIDE LOCKABLE CIRCUIT BREAKER.COOK-4 GUEST UNIT INDUCTIONCOOKTOP, 4-BURNER208/120V 2P 3W NONCONTINUOUS: 6.24 KVA 30/2 30 3/4"C,3#10,#10G HARDWIRED LOCKABLECIRCUITBREAKERN/ADIV 26 PROVIDE LOCKABLE CIRCUIT BREAKER.DRY GUEST UNIT DRYINGMACHINE208/120V 2P 3W NONCONTINUOUS: 5 KVA30/2 24.04 3#10,#10G RECEPTACLE NEMA 14-30R N/ADIV 26 PROVIDE GFCI CIRCUIT BREAKER WITH 6mATRIP.DW GUEST UNIT DISHWASHER 120V 1P 2WNONCONTINUOUS: 0.8 KVA 20/1 6.67 3/4"C,2#12,#12G RECEPTACLE NEMA 5-20RN/ADIV 26 PROVIDE COMBINATION AFCI/GFCI CIRCUITBREAKER WITH 6mA TRIP.GD GUEST UNIT GARBAGEDISPOSAL120V 1P 2WNONCONTINUOUS: 1/3 HP20/1 7.2 3/4"C,2#12,#12G RECEPTACLE NEMA 5-20RN/ADIV 26 PROVIDE COMBINATION AFCI/GFCI CIRCUITBREAKER WITH 6mA TRIP.HOOD GUEST UNIT COOKTOPHOOD120V 1P 2WNONCONTINUOUS: 0.17 KVA 20/1 1.4 3/4"C,2#12,#12G RECEPTACLE NEMA 5-20RN/ADIV 26 PROVIDE COMBINATION AFCI/GFCI CIRCUITBREAKER WITH 6mA TRIP.MW GUEST UNIT MICROWAVE 120V 1P 2WNONCONTINUOUS: 1 KVA20/1 8.33 3/4"C,2#12,#12G RECEPTACLE NEMA 5-20RN/ADIV 26 PROVIDE COMBINATION AFCI/GFCI CIRCUITBREAKER WITH 6mA TRIP.MW/HOOD COMBINATION GUEST UNITMICROWAVE/HOOD120V 1P 2WNONCONTINUOUS: 1 KVA20/1 8.33 3/4"C,2#12,#12G RECEPTACLE NEMA 5-20RN/ADIV 26 COMBINATION MICROWAVE/HOOD WITHINTEGRAL CONTROLS. PROVIDE COMBINATIONAFCI/GFCI CIRCUIT BREAKER WITH 6mA TRIP.PTAC-01 GUEST UNIT PTAC208/120V 2P 3W NONCONTINUOUS: 2.93 KVA 20/2 14.1 3/4"C,3#12,#12G RECEPTACLE NEMA 6-20RN/ADIV 26 VERIFY RECEPTACLE CONFIGURATION ANDMOUNTING LOCATION WITH MECHANICAL PRIORTO ROUGH-IN.REF GUEST UNITREFRIGERATOR120V 1P 2WNONCONTINUOUS: 0.18 KVA 20/1 1.5 3/4"C,2#12,#12G RECEPTACLE NEMA 5-20RN/ADIV 26 PROVIDE COMBINATION AFCI/GFCI CIRCUITBREAKER WITH 6mA TRIP.WASH GUEST UNIT WASHMACHINE120V 1P 2WNONCONTINUOUS: 1.2 KVA 20/1 10 3/4"C,2#12,#12G RECEPTACLE NEMA 5-20RN/ADIV 26 PROVIDE COMBINATION AFCI/GFCI CIRCUITBREAKER WITH 6mA TRIP.NOTE: EQUIPMENT IS TYPICAL FOR TYPICAL GUEST UNIT TYPES. SEE SHEETS E-502, E-503, AND E-504 FOR TYPICAL LOCATIONS AND ADDITIONAL INFORMATION. SEE ARCHITECTURAL PLANS FOR QUANTITIES AND LOCATIONS OF TYPICAL UNIT TYPES.KITCHEN EQUIPMENT SCHEDULECALLOUT EQUIPMENT DESCRIPTION VOLTAGELOAD TYPE OCP AMPS CONDUIT & WIRE CONNECTIONTYPEDISCONNECTDESCRIPTIONDISC NEMARATINGDISC BY CIRCUITNOTESKE-2 BEER GLYCOL SYSTEM 120V 1P 2WKITCHEN: 1/3 HP20/1 7.2 3/4"C,2#12,#12G RECEPTACLE NEMA 5-20RN/ADIV 26 L1KA-5 PROVIDE GFCI CIRCUITBREAKER WITH 6mA TRIP.KE-2.1 TAP WALL UPS120V 1P 2WKITCHEN: 0.24 KVA 20/1 2 3/4"C,2#12,#12G RECEPTACLE NEMA 5-20RN/ADIV 26 L1KA-1 PROVIDE GFCI CIRCUITBREAKER WITH 6mA TRIP.KE-2.2 DRAFT BEER COOLER 120V 1P 2WKITCHEN: 0.78 KVA 20/1 6.5 3/4"C,2#12,#12G RECEPTACLE NEMA 5-20RN/ADIV 26 L1KA-3 PROVIDE GFCI CIRCUITBREAKER WITH 6mA TRIP.KE-7 WALK-IN COOLER LIGHTS 120V 1P 2WLIGHTING: 0.6 KVA 20/1 5 3/4"C,2#12,#12G HARDWIRED LOCKABLE CIRCUITBREAKERN/ADIV 26 L1KA-17 CONTRACTOR TO MOUNT ANDINSTALL VAPOR-PROOF LIGHTS,FURNISHED BY KITCHENEQUIPMENT PROVIDER.PROVIDE CONNECTION ABOVECOOLER BOX. VERIFY EXACTLOCATION WITH EQUIPMENTPROVIDER.KE-7.1 WALK-IN COOLEREVAPORATION COIL120V 1P 2WMOTOR: 0.19 KVA20/1 1.6 3/4"C,2#12,#12G HARDWIRED MOTOR RATEDTOGGLE SWITCHNEMA 4X DIV 26 L1KA-19 FIELD VERIFY CONNECTIONLOCATION AND DISCONNECTMOUNTING LOCATION.KE-7.2 WALK-IN COOLERCONDENSING UNIT208/120V 2P 3W MOTOR: 1.58 KVA 15/2 7.6 3/4"C,3#10,#10G HARDWIRED 2P30A, NON-FUSED NEMA 3R DIV 26 L51-17,19 FIELD VERIFY CONNECTIONLOCATION AND DISCONNECTMOUNTING LOCATION.KE-20 DISPOSER208/120V 2P 3W KITCHEN: 1.81 KVA 20/2 8.7 3/4"C,3#12,#12G HARDWIRED LOCKABLE CIRCUITBREAKERN/ADIV 26 L1KA-13,15 FIELD COORDINATE WIRINGWITH WATER CONTROLCENTER.KE-22A UNDERCOUNTERDISHWASHER208V 3P 4WKITCHEN: 7.93 KVA 30/3 22 3/4"C,4#10,#10G HARDWIRED LOCKABLE CIRCUITBREAKERN/ADIV 26 L1KA-10,12,14 PROVIDE LOCKABLE GFCICIRCUIT BREAKER.KE-22B UNDERCOUNTERDISHWASHER208V 3P 4WKITCHEN: 7.93 KVA 30/3 22 3/4"C,4#10,#10G HARDWIRED LOCKABLE CIRCUITBREAKERN/ADIV 26 L1KA-4,6,8 PROVIDE LOCKABLE GFCICIRCUIT BREAKER.KE-26 NUGGET ICE MAKER 120V 1P 2WKITCHEN: 1.3 KVA 15/1 10.8 3/4"C,2#12,#12G RECEPTACLE NEMA 5-20RN/ADIV 26 L1KA-2 PROVIDE GFCI CIRCUITBREAKER WITH 6mA TRIP.KE-29 WAFFLE MAKER120V 1P 2WKITCHEN: 1.3 KVA 20/1 10.83 3/4"C,2#12,#12G RECEPTACLE NEMA 5-20R, GFCIN/ADIV 26 L1KA-24KE-30 JUICE DISPENSER120V 1P 2WKITCHEN: 0.96 KVA 20/1 8 3/4"C,2#12,#12G RECEPTACLE NEMA 5-20R, GFCIN/ADIV 26 L1KA-18KE-31 REFRIGERATED WORK TOP 120V 1P 2WKITCHEN: 0.36 KVA 20/1 3 3/4"C,2#12,#12G RECEPTACLE NEMA 5-20RN/ADIV 26 L1KA-11 PROVIDE GFCI CIRCUITBREAKER WITH 6mA TRIP.KE-41 REACH-IN FREEZER120V 1P 2WKITCHEN: 1.44 KVA 20/1 12 3/4"C,2#12,#12G RECEPTACLE NEMA 5-20RN/ADIV 26 L1KA-7 PROVIDE GFCI CIRCUITBREAKER WITH 6mA TRIP.KE-42A CONVECTION OVEN208/120V 2P 3W KITCHEN: 5.82 KVA 30/2 28 3/4"C,3#10,#10G HARDWIRED LOCKABLE CIRCUITBREAKERN/ADIV 26 L1KB-9,11 PROVIDE LOCKABLE CIRCUITBREAKER.KE-42B CONVECTION PROOFER 120V 1P 2WKITCHEN: 1.39 KVA 20/1 11.6 3/4"C,2#12,#12G RECEPTACLE NEMA 5-20RN/ADIV 26 L1KB-1 PROVIDE GFCI CIRCUITBREAKER WITH 6mA TRIP.KE-47 PASTA COOKER208/120V 2P 3W KITCHEN: 2.7 KVA 20/2 12.98 3/4"C,3#12,#12G RECEPTACLE NEMA 6-20RN/ADIV 26 L1KB-14,16 PROVIDE GFCI CIRCUITBREAKER WITH 6mA TRIP.KE-48 REFRIGERATED WORK TOP 120V 1P 2WKITCHEN: 0.36 KVA 20/1 3 3/4"C,2#12,#12G RECEPTACLE NEMA 5-20RN/ADIV 26 L1KB-5 PROVIDE GFCI CIRCUITBREAKER WITH 6mA TRIP.KE-49A INDUCTION RANGE208/120V 2P 3W KITCHEN: 2.6 KVA 20/2 12.5 3/4"C,3#12,#12G RECEPTACLE NEMA 6-20RN/ADIV 26 L1KB-8,10 PROVIDE GFCI CIRCUITBREAKER WITH 6mA TRIP.KE-49B INDUCTION RANGE208/120V 2P 3W KITCHEN: 2.6 KVA 20/2 12.5 3/4"C,3#12,#12G RECEPTACLE NEMA 6-20RN/ADIV 26 L1KB-2,4 PROVIDE GFCI CIRCUITBREAKER WITH 6mA TRIP.KE-50 MICROWAVE OVEN120V 1P 2WKITCHEN: 2 KVA20/1 16.67 3/4"C,2#12,#12G HARDWIRED NEMA 5-20RN/ADIV 26 L1KA-9 PROVIDE GFCI CIRCUITBREAKER WITH 6mA TRIP.KE-56 FROST TOP120V 1P 2WKITCHEN: 1.51 KVA 20/1 12.6 3/4"C,2#12,#12G HARDWIRED NEMA 5-20R, GFCIN/ADIV 26 L1KA-16KE-60 POP-UP TOASTER208/120V 2P 3W KITCHEN: 2.6 KVA 15/2 12.5 3/4"C,3#12,#12G HARDWIRED NEMA 6-15RN/ADIV 26 L1KA-20,22 PROVIDE GFCI CIRCUITBREAKER WITH 6mA TRIP.KE-61A INDUCTION WARMER 120V 1P 2WKITCHEN: 0.65 KVA 20/1 5.42 3/4"C,2#12,#12G RECEPTACLE NEMA 5-20RN/ADIV 26 L1KA-21 PROVIDE GFCI CIRCUITBREAKER WITH 6mA TRIP.KE-61B INDUCTION WARMER 120V 1P 2WKITCHEN: 0.65 KVA 20/1 5.42 3/4"C,2#12,#12G RECEPTACLE NEMA 5-20RN/ADIV 26 L1KA-23 PROVIDE GFCI CIRCUITBREAKER WITH 6mA TRIP.KE-61C INDUCTION WARMER 120V 1P 2WKITCHEN: 0.65 KVA 20/1 5.42 3/4"C,2#12,#12G RECEPTACLE NEMA 5-20RN/ADIV 26 L1KA-25 PROVIDE GFCI CIRCUITBREAKER WITH 6mA TRIP.KE-61D INDUCTION WARMER 120V 1P 2WKITCHEN: 0.65 KVA 20/1 5.42 3/4"C,2#12,#12G RECEPTACLE NEMA 5-20RN/ADIV 26 L1KA-27 PROVIDE GFCI CIRCUITBREAKER WITH 6mA TRIP.KE-84 OPEN DISPLAYERMERCHANDISER120V 1P 2WKITCHEN: 1.92 KVA 20/1 16 3/4"C,2#12,#12G RECEPTACLE NEMA 5-20RN/ADIV 26 L1KA-35 PROVIDE GFCI CIRCUITBREAKER WITH 6mA TRIP.KE-85 OPEN DISPLAYERMERCHANDISER208/120V 2P 3W KITCHEN: 1.99 KVA 20/2 9.55 3/4"C,3#12,#12G RECEPTACLE NEMA 6-20RN/ADIV 26 L1KA-31,33 PROVIDE GFCI CIRCUITBREAKER WITH 6mA TRIP.KE-89 REACH-IN FREEZER120V 1P 2WKITCHEN: 1.14 KVA 20/1 9.5 3/4"C,2#12,#12G RECEPTACLE NEMA 5-20RN/ADIV 26 L1KA-29 PROVIDE GFCI CIRCUITBREAKER WITH 6mA TRIP.KE-96A GAS GRILL120V 1P 2WKITCHEN: 0.1 KVA 20/1 0.83 3/4"C,2#12,#12G HARDWIRED LOCKABLE CIRCUITBREAKERN/ADIV 26 LPAT-1 PROVIDE CONNECTION FORGAS IGNITER CIRCUIT. VERIFYREQUIREMENTS WITH GRILLPROVIDER.KE-96B GAS GRILL120V 1P 2WKITCHEN: 0.1 KVA 20/1 0.83 3/4"C,2#12,#12G HARDWIRED LOCKABLE CIRCUITBREAKERN/ADIV 26 LPAT-3 PROVIDE CONNECTION FORGAS IGNITER CIRCUIT. VERIFYREQUIREMENTS WITH GRILLPROVIDER.KE-98 HANDWASHING SYSTEM 120V 1P 2WKITCHEN: 0.74 KVA 20/1 6.2 3/4"C,2#12,#12G RECEPTACLE NEMA 5-20R, GFCIN/ADIV 26 LPAT-5POOL EQUIPMENT SCHEDULECALLOUT EQUIPMENT DESCRIPTION VOLTAGELOAD TYPEOCP AMPS CONDUIT & WIRE CONNECTIONTYPEDISCONNECTDESCRIPTIONDISC NEMARATINGDISC BY CIRCUITNOTESPEQ-1 POOL RECIRCULATIONPUMP120V 1P 2WMOTOR: 1.92 KVA20/1 16 3/4"C,2#12,#12G HARDWIRED MOTORRATEDTOGGLESWITCHNEMA 4X DIV 26 L1P-1PEQ-2 SPLASH PADRECIRCULATION PUMP120V 1P 2WMOTOR: 1.92 KVA20/1 16 3/4"C,2#12,#12G HARDWIRED MOTORRATEDTOGGLESWITCHNEMA 4X DIV 26 L1P-3PEQ-3 SPLASH PAD FEATUREPUMP120V 1P 2WMOTOR: 1.92 KVA20/1 16 3/4"C,2#12,#12G HARDWIRED MOTORRATEDTOGGLESWITCHNEMA 4X DIV 26 L1P-5PEQ-6 POOL CHEMICALCONTROLLER120V 1P 2WNONCONTINUOUS: 0.4 KVA 20/1 3.3 3/4"C,2#12,#12GGFCIRECEPTACLENEMA 5-20RN/ADIV 26 L1P-7PEQ-7 SPLASH PAD CHEMICALCONTROLLER120V 1P 2WNONCONTINUOUS: 0.4 KVA 20/1 3.3 3/4"C,2#12,#12GGFCIRECEPTACLENEMA 5-20RN/ADIV 26 L1P-9PEQ-8.1 POOL LIGHTS120V 1P 2WNONCONTINUOUS: 0.24 KVA 20/1 2 3/4"C,2#12,#12G HARDWIRED LOCKABLECIRCUITBREAKERN/ADIV 26 L1P-4 PROVIDE LOCKABLE CIRCUITBREAKERPEQ-8.2 POOL LIGHTS120V 1P 2WNONCONTINUOUS: 0.24 KVA 20/1 2 3/4"C,2#12,#12G HARDWIRED LOCKABLECIRCUITBREAKERN/ADIV 26 L1P-4 PROVIDE LOCKABLE CIRCUITBREAKERPEQ-9 POOL AUTOFILL120V 1P 2WNONCONTINUOUS: 0.06 KVA 20/1 0.5 3/4"C,2#12,#12GGFCIRECEPTACLENEMA 5-20RN/ADIV 26 L1P-6PEQ-10 SPLASH PAD AUTOFILL 120V 1P 2WNONCONTINUOUS: 0.06 KVA 20/1 0.5 3/4"C,2#12,#12GGFCIRECEPTACLENEMA 5-20RN/ADIV 26 L1P-6PEQ-11 POOL HEATER120V 1P 2WNONCONTINUOUS: 0.6 KVA 20/1 5 3/4"C,2#12,#12G HARDWIRED LOCKABLECIRCUITBREAKERN/ADIV 26 L1P-8 PROVIDE LOCKABLE CIRCUITBREAKERPEQ-12 SPLASH PAD HEATER 120V 1P 2WNONCONTINUOUS: 0.6 KVA 20/1 5 3/4"C,2#12,#12G HARDWIRED LOCKABLECIRCUITBREAKERN/ADIV 26 L1P-10 PROVIDE LOCKABLE CIRCUITBREAKEREV CHARGING EQUIPMENT SCHEDULECALLOUT EQUIPMENT DESCRIPTION VOLTAGELOAD TYPEOCP AMPS CONDUIT & WIRE CONNECTIONTYPEDISCONNECTDESCRIPTIONDISC NEMARATINGDISC BY CIRCUITNOTESEV-1 EV CHARGING PEDESTAL 208V 2P 2WCONTINUOUS: 6.66 KVA40/2 32 3/4"C,2#8,#10G HARDWIRED LOCKABLECIRCUITBREAKERN/ADIV 26 EV-1,3 PROVIDE DUAL EV CHARGINGPEDESTAL WITH (2) 40A, SAEJ1772 STANDARD PLUG. BASISOF DESIGN: CHARGEPOINTCT4021-GW1.EV-2 EV CHARGING PEDESTAL 208V 2P 2WCONTINUOUS: 6.66 KVA40/2 32 3/4"C,2#8,#10G HARDWIRED LOCKABLECIRCUITBREAKERN/ADIV 26 EV-5,7 CIRCUIT SHOWN FOR SECONDPLUG ON DUAL CHARGINGPEDESTAL. SEE SITE PLAN FORLOCATION.LAUNDRY EQUIPMENT SCHEDULECALLOUT EQUIPMENT DESCRIPTION VOLTAGELOAD TYPEOCP AMPS CONDUIT & WIRE CONNECTIONTYPEDISCONNECTDESCRIPTIONDISC NEMARATINGDISC BY CIRCUITNOTESDRY-1.1 GUEST LAUNDRY DRYER 208/120V 2P 3W NONCONTINUOUS: 4.75 KVA 30/2 22.84 3/4"C,3#10,#10G RECEPTACLE NEMA 14-30R N/ADIV 26 L11-20,22 VERIFY PLUG TYPE WITHEQUIPMENT PROVIDER PRIORTO ROUGH-IN.DRY-1.2 GUEST LAUNDRY DRYER 208/120V 2P 3W NONCONTINUOUS: 4.75 KVA 30/2 22.84 3/4"C,3#10,#10G RECEPTACLE NEMA 14-30R N/ADIV 26 L11-24,26 VERIFY PLUG TYPE WITHEQUIPMENT PROVIDER PRIORTO ROUGH-IN.DRY-1.3 GUEST LAUNDRY DRYER 208/120V 2P 3W NONCONTINUOUS: 4.75 KVA 30/2 22.84 3/4"C,3#10,#10G RECEPTACLE NEMA 14-30R N/ADIV 26 L11-28,30 VERIFY PLUG TYPE WITHEQUIPMENT PROVIDER PRIORTO ROUGH-IN.DRY-1.4 GUEST LAUNDRY DRYER 208/120V 2P 3W NONCONTINUOUS: 4.75 KVA 30/2 22.84 3/4"C,3#10,#10G RECEPTACLE NEMA 14-30R N/ADIV 26 L11-32,34 VERIFY PLUG TYPE WITHEQUIPMENT PROVIDER PRIORTO ROUGH-IN.DRY-2.1 COMMERCIAL DRYER 208V 3P 4WNONCONTINUOUS: 4.32 KVA 15/3 12 3/4"C,4#12,#12G HARDWIRED3P30A, 15AFUSESNEMA 1 DIV 26 L11-2,4,6 VERIFY EXACT CONNECTIONLOCATIONS ANDREQUIREMENTS WITHEQUIPMENT PROVIDER.DRY-2.2 COMMERCIAL DRYER 208V 3P 4WNONCONTINUOUS: 4.32 KVA 15/3 12 3/4"C,4#12,#12G HARDWIRED3P30A, 15AFUSESNEMA 1 DIV 26 L11-8,10,12 VERIFY EXACT CONNECTIONLOCATIONS ANDREQUIREMENTS WITHEQUIPMENT PROVIDER.DRY-2.3 COMMERCIAL DRYER 208V 3P 4WNONCONTINUOUS: 4.32 KVA 15/3 12 3/4"C,4#12,#12G HARDWIRED3P30A, 15AFUSESNEMA 1 DIV 26 L11-14,16,18 VERIFY EXACT CONNECTIONLOCATIONS ANDREQUIREMENTS WITHEQUIPMENT PROVIDER.WASH-1.1 GUEST LAUNDRY DRYER 120V 1P 2WNONCONTINUOUS: 1.8 KVA 20/1 15 3/4"C,2#10,#10G RECEPTACLE NEMA 5-20RN/ADIV 26 L11-19WASH-1.2 GUEST LAUNDRY DRYER 120V 1P 2WNONCONTINUOUS: 1.8 KVA 20/1 15 3/4"C,2#10,#10G RECEPTACLE NEMA 5-20RN/ADIV 26 L11-21WASH-1.3 GUEST LAUNDRY DRYER 120V 1P 2WNONCONTINUOUS: 1.8 KVA 20/1 15 3/4"C,2#10,#10G RECEPTACLE NEMA 5-20RN/ADIV 26 L11-23WASH-1.4 GUEST LAUNDRY DRYER 120V 1P 2WNONCONTINUOUS: 1.8 KVA 20/1 15 3/4"C,2#10,#10G RECEPTACLE NEMA 5-20RN/ADIV 26 L11-25WASH-2.1 COMMERCIAL WASHER 208V 3P 4WNONCONTINUOUS: 3.6 KVA 15/3 10 3/4"C,4#12,#12G HARDWIRED3P30A, 15AFUSESNEMA 1 DIV 26 L11-1,3,5 VERIFY EXACT CONNECTIONLOCATIONS ANDREQUIREMENTS WITHEQUIPMENT PROVIDER.WASH-2.2 COMMERCIAL WASHER 208V 3P 4WNONCONTINUOUS: 3.6 KVA 15/3 10 3/4"C,4#12,#12G HARDWIRED3P30A, 15AFUSESNEMA 1 DIV 26 L11-7,9,11 VERIFY EXACT CONNECTIONLOCATIONS ANDREQUIREMENTS WITHEQUIPMENT PROVIDER.WASH-2.3 COMMERCIAL WASHER 208V 3P 4WNONCONTINUOUS: 3.6 KVA 15/3 10 3/4"C,4#12,#12G HARDWIRED3P30A, 15AFUSESNEMA 1 DIV 26 L11-13,15,17 VERIFY EXACT CONNECTIONLOCATIONS ANDREQUIREMENTS WITHEQUIPMENT PROVIDER.32 MERCHANT STREET, SUITE 208HONOLULU, HI 96813808-352-5299OWNER:HOMEWOOD SUITES by HILTON
SPOKANE VALLEY, WA
13515 E. Carlisle Avenue
Spokane Valley, WA 99216FSC PROJECT NO. 21012PERMITDOCUMENTSMay 31, 2024GL8 MirabeauPoint, LLCTMK:PID: 45101.0401 10909 E. Pierce LaneSpokane, WA 99206(509) 919-0901Revision ScheduleNumber Description Date5915 S REGAL STREETSUITE 201SPOKANE, WA 99223PH: 509.473.9218Kelly@kwrllc.comwww.kwrllc.com5/30/2024 12:49:01 PMSTATE OF WASHINGTONREGISTERED PROFESSIONAL ENG
INEER48350 KELLY A
N
DREW WATERMAN05.31.24EQUIPMENTSCHEDULESE-003
LUMINAIRE SCHEDULETYPESYMBOLMFGR & CATALOG NUMBERDRIVERMOUNTING LIGHTSOURCELUMENOUTPUTINPUTWATTSLUMENS/WATTNOTESB06ALPHABET#NU6RD SW 20LM 30K 90 HE70 WH WH NC UNV DIM10120-277V, 0-10VDIMMINGRECESSED LED, 3000K 1660 LM 17W 98 6" RECESSED DOWNLIGHTB06EALPHABET#NU6RD SW 20LM 30K 90 HE70 WH WH NC UNV DIM10EM10CA20120-277V, 0-10VDIMMINGRECESSED LED, 3000K 1660 LM 17W 98 6" RECESSED DOWNLIGHT, EMERGENCY. PROVIDE UL924 BATTERY PACK.WHERE LOCATED IN INACCESSIBLE CEILING SPACE, MOUNT IN NEARESTACCESSIBLE CEILING OR NON-PUBLIC UTILITY SPACE WITHIN 50'.B20AALPHABET#NU4QA 15LM 30K 90 35D DS WH WH NC UNV DIM10120-277V, 0-10VDIMMINGRECESSED LED, 3000K 1280 LM 13W 98 SQUARE LED DOWNLIGHT, ADJUSTABLE.B21ALPHABET#NU4QD SW 25LM 40K 90 HE70 WH WH NC UNV DIM10120-277V, 0-10VDIMMINGRECESSED LED, 4000K 2000 LM 20W 100 SQUARE LED DOWNLIGHT, EXTERIOR. WET LOCATION RATED.B21EALPHABET#NU4QD SW 25LM 40K 90 HE70 WH WH NC UNV DIM10EM10CA20120-277V, 0-10VDIMMINGRECESSED LED, 4000K 2000 LM 20W 100 SQUARE LED DOWNLIGHT, EXTERIOR, EMERGENCY. WET LOCATIONRATED. PROVIDE UL924 BATTERY PACK. WHERE LOCATED ININACCESSIBLE CEILING SPACE, MOUNT IN NEAREST ACCESSIBLE CEILINGOR NON-PUBLIC UTILITY SPACE WITHIN 50'.B22ALPHABET#NU4QD SW 25LM 40K 90 HE70 WH WH NC UNV DIM10120-277V, 0-10VDIMMINGRECESSED LED, 4000K 2000 LM 20W 98 SQUARE LED DOWNLIGHT, RESTROOMSB22AALPHABET#NU4QA 15LM 40K 90 35D DS WH WH NC UNV DIM10120-277V, 0-10VDIMMINGRECESSED LED, 4000K 1200 LM 14W 85 SQUARE LED DOWNLIGHT, ADJUSTABLE, RESTROOMSB22AEALPHABET#NU4QA 15LM 40K 90 35D DS WH WH NC UNV DIM10EM10CA20120-277V, 0-10VDIMMINGRECESSED LED, 4000K 1200 LM 14W 85 SQUARE LED DOWNLIGHT, ADJUSTABLE, EMERGENCY. PROVIDE UL924BATTERY PACK. WHERE LOCATED IN INACCESSIBLE CEILING SPACE,MOUNT IN NEAREST ACCESSIBLE CEILING OR NON-PUBLIC UTILITY SPACEWITHIN 50'.B22EALPHABET#NU4QD SW 25LM 40K 90 HE70 WH WH NC UNV DIM10EM10CA20120-277V, 0-10VDIMMINGRECESSED LED, 4000K 2000 LM 20W 100 SQUARE LED DOWNLIGHT, RESTROOMS, EMERGENCY. PROVIDE UL924BATTERY PACK. WHERE LOCATED IN INACCESSIBLE CEILING SPACE,MOUNT IN NEAREST ACCESSIBLE CEILING OR NON-PUBLIC UTILITY SPACEWITHIN 50'.B25ALPHABET#NU4QW 10LM 30K 90 WW WH WH NC UNV120-277V, 0-10VDIMMINGRECESSED LED, 3000K 840 LM 9W 93 SQUARE LED DOWNLIGHT, WALL WASH OPTIC. ORIENT OPTIC ASINDICATED BY CHEVRONS ON LIGHTING PLANS.B26ALPHABET#NU4QW 10LM 40K 90 WW WH WH NC UNV120-277V, 0-10VDIMMINGRECESSED LED, 4000K 840 LM 9W 93 SQUARE LED DOWNLIGHT, WALL WASH OPTIC, RESTROOMS. ORIENT OPTICAS INDICATED BY CHEVRONS ON LIGHTING PLANS.C48LITHONIA#CLX L48 4000LM SEF FDL MVOLT GZ10 40K 80CRI WH120-277V, 0-10VDIMMINGSURFACE LED, 4000K 4000LM 26W 153 4' LED STRIPLIGHTC48ELITHONIA#CLX L48 4000LM SEF FDL MVOLT GZ10 40K 80CRIE10WLCP WH120-277V, 0-10VDIMMINGSURFACE LED, 4000K 4000 LM 26W 153 4' LED STRIPLIGHT, EMERGENCY. PROVIDE INTEGRAL UL924 BATTERYPACK.C96LITHONIA#CLX L96 8000LM SEF FDL MVOLT GZ10 40K 80CRI WH120-277V, 0-10VDIMMINGSURFACE LED, 4000K 8000 LM 51W 156 8' LED STRIPLIGHTC96ELITHONIA#CLX L96 8000LM SEF FDL MVOLT GZ10 40K 80CRIE10WLCP WH120-277V, 0-10VDIMMINGSURFACE LED, 4000K 8000 LM 51W 156 8' LED STRIPLIGHT, EMERGENCY. PROVIDE INTEGRAL UL924 BATTERYPACK.D04AXIS#SCDI 300 500 80 30 BW FL 4' AP UNV DP 1120-277V, 0-10VDIMMINGSIDE MOUNTTO ADJACENTTRELLISBEAM, LENSFLUSH WITHBEAMLED, 3000K 1200LM UP /2000LM DN31W 105 4' LINEAR DIRECT/INDIRECT, LOBBY TRELLIS. LUMINAIRE SHALL BE SIDEMOUNTED TO SIDE OF TRELLIS BEAM, LENS FLUSH WITH BOTTOM.G01ELITHONIA#FEM L48 4000LM LPACL WD MVOLT GZ10 40K 80CRIFEMSMB E10WMCP120-277V, 0-10VDIMMINGSURFACE LED, 4000K 4066 LM 24W 169 48" LED ELEVATOR PIT LIGHT. STRIP LIGHT WITH CLEAR LENS AND NEMA4X HOUSING AND WET LOCATION FITTING(S). PROVIDE UL924 EMERGENCYBATTERY PACK. COORDINATE FINAL FIXTURE MOUNTING WITH ELEVATORINSTALLER PRIOR TO ROUGH-IN. PROVIDE SUFRACE MOUNTINGBRACKETS.G02ELITHONIA#FEM L48 6000LM LPACL MD MVOLT GZ10 40K 80CRIFEMSMB E10WMCP120-277V, 0-10VDIMMINGSURFACE LED, 4000K 6061 LM 38W 159 48" LED ELEVATOR PIT LIGHT. STRIP LIGHT WITH CLEAR LENS AND NEMA4X HOUSING AND WET LOCATION FITTING(S). PROVIDE UL924 EMERGENCYBATTERY PACK. COORDINATE FINAL FIXTURE MOUNTING WITH ELEVATORINSTALLER PRIOR TO ROUGH-IN. PROVIDE SUFRACE MOUNTINGBRACKETS.L06AXIS#EX2R 750 80 40 SO 6 W UNV DP 1 DF120-277V, 0-10VDIMMINGRECESSED LED, 4000K 4500LM 43W 104 6' RECESSED LINEAR, WET LOCATION RATED.L06AAXIS#EX2R 750 80 40 WW 6 W UNV DP 1 DF120-277V, 0-10VDIMMINGRECESSED LED, 4000K 4500LM 43W 104 6' RECESSED LINEAR, WET LOCATION RATED, WALLWASH. ORIENTATIONAS INDICATED BY CHEVRON ON PLANS.L07FLUXWERX#NT1 L D1 B D 30 F2 M 6'120-277V, 0-10VDIMMINGRECESSED LED, 3000K 5400LM 57W 95 2" APERTURE 6' RECESSED LINEAR, REGRESSED LENS.L07EFLUXWERX#NT1 L D1 B D 30 F2 M 6' B(1)120-277V, 0-10VDIMMINGRECESSED LED, 3000K 5400LM 57W 95 2" APERTURE 6' RECESSED LINEAR, REGRESSED LENS, EMERGENCY.PROVIDE INTEGRAL UL924 BATTERY PACK.L12AXIS#EX2R 750 80 40 SO 12 W UNV DP 1 DF120-277V, 0-10VDIMMINGRECESSED LED, 4000K 9000LM 89W 101 12' RECESSED LINEAR, WET LOCATION RATED.L12EAXIS#EX2R 750 80 40 SO 12 W UNV DP 1 DF B(1)120-277V, 0-10VDIMMINGRECESSED LED, 4000K 9000LM 89W 101 12' RECESSED LINEAR, WET LOCATION RATED, EMERGENCY. PROVIDEINTEGRAL UL924 BATTERY PACK.L16AXIS#EX2WD 500 80 40 SO S(16) B UNV DP 1120-277V, 0-10VDIMMINGSIDE MOUNTTO ADJACENTTRELLISBEAM, LENSFLUSH WITHBEAMLED, 4000K 8000LM 79W 101 16' LINEAR, PATIO TRELLIS, SIDE MOUNTED TO ADJACENT BEAM, LENSFLUSH WITH BOTTOM OF BEAMS.P02REMINGTON LIGHTING#STYLE 15309120V, ELVDIMMINGPENDANT (8) E26 LEDREPLACEMENT,3000KTBD80WMAX(10WLAMPS)TBD LOBBY DECORATIVE PENDANT CLUSTERP03REMINGTON LIGHTING#STYLE 15310120V, ELVDIMMINGPENDANT,+64"(1) E26 LEDREPLACEMENT,4000KTBD 15WMAXTBD PUBLIC RESTROOM DECORATIVE PENDANTP04REMINGTON LIGHTING#STYLE 15307120V, ELVDIMMINGPENDANT,+64"(1) E26 LEDREPLACEMENT,3000KTBD 15WMAXTBD RECEPTION DECORATIVE PENDANTP05ARKANSAS LIGHTING#ITEM 4400P120V, ELVDIMMINGPENDANT,+6'-9"(1) E26 LEDREPLACEMENT,4000KTBD 15WMAXTBD OUTDOOR KITCHEN ISLAND PENDANTP06ALW#CRT3/WL 13 83 40 80 DF 07 83 40 80 DF D V10 1C SB120V, ELVDIMMINGPENDANT,+9'-0"LED, 4000K 1196LM UP /648LM DN21W 88 OUTDOOR DIRECT/INDIRECT CYLINDER PENDANT. PROVIDE NEMA 4XJUNCTION BOX ABOVE TRELLIS FOR BRANCH CIRCUITING, WITH CONDUITNIPPLE BETWEEN BEAMS TO CANOPY MOUNTED BELOW. FIELDCOORDINATE EXACT MOUNTING REQUIREMENTS.R01-11AXIS#B2SQRLED 300 80 40 WW S(11'4") W UNV DP 1 DF120-277V, 0-10VDIMMINGRECESSED LED, 4000K 3300 LM 31W 107 RECESSED LINEAR WALL WASH, RESTROOMS. WALL TO WALLINSTALLATION. VERIFY EXACT LENGTH PRIOR TO ORDERING.R08AXIS#WBRLED 750 80 40 S 8 W UNV DP 1 D +N120-277V, 0-10VDIMMINGRECESSED LED, 4000K 6000 LM 70W 87 8' RECESSED LINEAR RECESSED WET BEAM. PROVIDE WITH NATATORIUMOPTION.R08EAXIS#WBRLED 750 80 40 S 8 W UNV DP 1 D B1 +N120-277V, 0-10VDIMMINGRECESSED LED, 4000K 8000 LM 70W 87 8' RECESSED LINEAR RECESSED WET BEAM. PROVIDE WITH NATATORIUMOPTION. PROVIDE INTEGRAL UL924 BATTERY PACK.R21LITHONIA#EPANL 2X2 4000LM 80CRI 40K MIN10 ZT MVOLT120-277V, 0-10VDIMMINGRECESSED LED, 4000K 4121 LM 37W 111 2X2 LED TROFFER, BACK OF HOUSE, HIGH OUTPUTR21ELITHONIA#EPANL 2X2 4000LM 80CRI 40K MIN10 ZT MVOLT E10WCP120-277V, 0-10VDIMMINGRECESSED LED, 4000K 4121 LM 37W 111 2X2 LED TROFFER, BACK OF HOUSE, HIGH OUTPUT, EMERGENCY. PROVIDEINTEGRAL UL924 BATTERY PACK.R22MARK ARCHITECTURAL LIGHTING#WHSPR 2X2 80CRI 40K 3000LM MIN10 MVOLT SWC120-277V, 0-10VDIMMINGRECESSED LED, 4000K 2969 LM 24W 125 2X2 LED TROFFER, FRONT OF HOUSER24MARK ARCHITECTURAL LIGHTING#WHSPR 2X4 80CRI 40K 3000LM MIN10 MVOLT SWC120-277V, 0-10VDIMMINGRECESSED LED, 4000K 3014 LM 21W 143 2X4 LED TROFFER, FRONT OF HOUSER25LITHONIA#EPANL 2X4 4000LM 80CRI 40K MIN10 ZT MVOLT120-277V, 0-10VDIMMINGRECESSED LED, 4000K 3963 LM 37W 107 2X4 LED TROFFER, BACK OF HOUSER25ELITHONIA#EPANL 2X4 4000LM 80CRI 40K MIN10 ZT MVOLT E10WCP120-277V, 0-10VDIMMINGRECESSED LED, 4000K 3963 LM 37W 107 2X4 LED TROFFER, BACK OF HOUSE, EMERGENCY. PROVIDE INTEGRALUL924 BATTERY PACK.R26MARK ARCHITECTURAL LIGHTING#WHSPR 2X4 80CRI 30K 3000LM MIN10 MVOLT SWC120-277V, 0-10VDIMMINGRECESSED LED, 3000K 3014 LM 21W 143 2X4 LED TROFFER, MEETING ROOMR27MARK ARCHITECTURAL LIGHTING#WHSPR 2X4 80CRI 40K 3000LM MIN10 MVOLT SWC DGA24120-277V, 0-10VDIMMINGRECESSED LED, 4000K 3014 LM 21W 143 2X4 LED TROFFER, FRONT OF HOUSE, GWB CEILINGLUMINAIRE SCHEDULE (CONT.)TYPESYMBOLMFGR & CATALOG NUMBERDRIVERMOUNTING LIGHTSOURCELUMENOUTPUTINPUTWATTSLUMENS/WATTNOTESR44NULITE#BRT4 44 50 L30 UNV D WH120-277V, 0-10VDIMMINGRECESSED LED, 3000K 5000 LM 51W 78 4'X4' RECESSED INDIRECT TROFFERS02LITHONIAHEAD:#DSX1 LED P4 40K T2M MVOLT SPA NLTAIR2 PIRHN DBLXDPOLE:#SSS 22'-6" 4C DM19AS DBLXD120-277V, NLIGHTAIR DIMMINGPOLE, +25'-0"(22'-6" POLE,30" EXPOSEDBASE)LED, 4000K 15849 LM 124W 128 LED SITE POLE, TYPE II MEDIUM DISTRIBUTION. PROVIDE INTEGRALWIRELESS CONTROL MODULE FOR GROUPED DAYLIGHT / VACANCYRESPONSE.S03LITHONIAHEAD:#DSX1 LED P4 40K T3M MVOLT SPA NLTAIR2 PIRHN DBLXDPOLE:#SSS 22'-6" 4C DM19AS DBLXD120-277V, NLIGHTAIR DIMMINGPOLE, +25'-0"(22'-6" POLE,30" EXPOSEDBASE)LED, 4000K 16032 LM 124W 129 LED SITE POLE, TYPE III MEDIUM DISTRIBUTION. PROVIDE INTEGRALWIRELESS CONTROL MODULE FOR GROUPED DAYLIGHT / VACANCYRESPONSE.S03-2LITHONIAHEAD:#DSX1 LED P4 40K T3M MVOLT SPA NLTAIR2 PIRHN DBLXDPOLE:#SSS 22'-6" 4C DM28AS DBLXD120-277V, NLIGHTAIR DIMMINGPOLE, +25'-0"(22'-6" POLE,30" EXPOSEDBASE)LED, 4000K 16032 LM 124W 129 LED SITE POLE, TYPE III MEDIUM DISTRIBUTION. PROVIDE INTEGRALWIRELESS CONTROL MODULE FOR GROUPED DAYLIGHT / VACANCYRESPONSE.S12LITHONIALUMINAIRE:#RADPT LED P2 40K ASY PT4 NLTAIR2 DBLXDPOLE:#RSS 12.5 RB PT DBLXD277V, 0-10VDIMMINGPOLE, +12'-6"(FLUSH BASE)LED, 4000K 4898 LM 38W 128 LED POST TOP LIGHT - PET AREAS21LITHONIA#KBA8 LED 12C 530 40K ASY MVOLT DBLXD120-277VBOLLARD,CONCRETEBASELED, 4000K 1741LM 22W 79 LED BOLLARD. ASYMMETRIC DISTRIBUTION SHALL BE ORIENTED TOWARDPATHWAYS/HARDSCAPE AS INDICATED.SZ01KLUS#KWP-CR40-1220-24EXTRUSION: KLUS #LIPOD-50LENS: LIGER-45POWER SUPPLY EXTRUSION,FIREPLACENOTCHLED, 4000K 223LM/FT 2.9W/FT 76 EXTERIOR ACCENT LIGHT, FIREPIT. WET LOCATION RATED. PROVIDELENGTHS AS SHOWN ON PLANS. SEE ARCHITECTURAL SHEET A-406 FORMOUNTING DETAILS. COORDINATE WITH FIREPLACE FABRICATOR FORFIXTURE AND POWER SUPPLY MOUNTING.SZ02KLUS#KWP-CR40-1220-24EXTRUSION: KLUS #LIPOD-50LENS: LIGER-45POWER SUPPLY EXTRUSION,SURFACEUNDERBACKSPLASHLED, 4000K 223LM/FT 2.9W/FT 76 EXTERIOR ACCENT LIGHT, BARBEQUE / SINK BACKSPLASH. WET LOCATIONRATED. PROVIDE LENGTHS AS SHOWN ON PLANS. SEE ARCHITECTURALSHEET A-406 FOR MOUNTING DETAILS. COORDINATE WITH CASEWORKFABRICATOR FOR FIXTURE AND POWER SUPPLY MOUNTING.SZ03KLUS#KWP-CR40-1220-24EXTRUSION: KLUS #LIPOD-50LENS: LIGER-45POWER SUPPLY EXTRUSION,SURFACEUNDERBACKSPLASHLED, 4000K 223LM/FT 2.9W/FT 76 EXTERIOR ACCENT LIGHT, EXTERIOR KITCHEN ISLAND UNDERCOUNTER.WET LOCATION RATED. PROVIDE LENGTHS AS SHOWN ON PLANS. SEEARCHITECTURAL SHEET A-406 FOR MOUNTING DETAILS. COORDINATEWITH CASEWORK FABRICATOR FOR FIXTURE AND POWER SUPPLYMOUNTING.W01REMINGTON LIGHTING#STYLE 15311.01120V, ELVDIMMINGWALL, +6'-0" (1) E26 LEDREPLACEMENT,3000KN/A 15WMAXN/A CORRIDOR DECORATIVE WALL SCONCEW02ALW#CRU3/WL 07 83 40 40 FT 13 83 40 40 N V10 1C SG120-277VWALLLED, 4000K 1839 LM 18W 108 EXTERIOR COURTYARD DECORATIVE WALL SCONCE, DIRECT/INDIRECTW02EALW#CRU3/WL 07 83 40 40 FT 13 83 40 40 R V10 1C SG EMB120-277VWALLLED, 4000K 1839 LM 18W 108 EXTERIOR COURTYARD DECORATIVE WALL SCONCE, DIRECT/INDIRECT,EMERGENCY. PROVIDE REMOTE MOUNTED UL924 BATTERY, MOUNTED INNEAREST ACCESSIBLE CEILING SPACE.W03ALW#CRU3/WL 13 83 40 40 FT 13 83 40 40 N V10 1C SB120-277VWALLLED, 4000K 2392 LM 24W 102 EXTERIOR DECORATIVE WALL SCONCE, DIRECT/INDIRECTW03EALW#CRU3/WL 13 83 40 40 FT 13 83 40 40 R V10 1C SB EMB120-277VWALLLED, 4000K 2392 LM 24W 102 EXTERIOR DECORATIVE WALL SCONCE, DIRECT/INDIRECT, EMERGENCY.REMOTE UL924 BATTERY PACK, FIELD COORDINATE BATTERY MOUNTINGLOCATION IN NEAREST INTERIOR ACCESSIBLE CEILING SPACE.W04SPI LIGHTING#EEW12280 L46W PT51 120-277V 4000K 80 IND NAT120-277V, 0-10VDIMMINGWALL, +10'-0"AFFLED, 4000K 5980 LM 46W 130 WALL MOUNTED INDIRECT LUMENAIRE FOR INDOOR POOL. PROVIDE WITHNATATORIUM OPTION. FIELD ADJUST TO FORWARD DISTRIBUTION OF 35DEGREES.W06WAC LIGHTING#3611-30-BK12V, VIA POWERSUPPLYWALL, +6'-0"AFFLED, 4000K 325LM UP /325LM DN7.5W 86 DECORATIVE DIRECT/INDIRECT WALL SCONCE, COLUMN RECESSEDNOTCHES. POWERED VIA REMOTE MOUNTED 12V POWER SUPPLY. FIELDCOORDINATE MOUNTING REQUIREMENTS ON DECORATIVE FACADE OFCOLUMN. CCT SHALL BE SET TO 4000K.W24LITHONIA#FMVCSLS 24IN MVOLT 30K35K40K 90CRI BN120-277VWALL, +6"ABOVEVANITYMIRRORLED, 3000K 1740 LM 18W 96 24" LED VANITY. FIELD SELECT 3000K COLOR TEMPERATURE.W48EAXIS#TB2WDLED 750 80 40 ASO 4 AP UNV DP 1 B(1)120-277V, 0-10VDIMMINGWALL, +8'-6" LED, 4000K 3000 LM 30W 100 4' STAIRWELL LED, EMERGENCY. PROVIDE UL924 EMERGENCY BATTERYPACK.X01LITHONIA#LQM S W 3 G 120/277 EL N SDELECTRONIC UNIVERSAL LED, GREEN N/A 1W N/A LED EXIT LIGHT (SINGLE FACE). CHEVRONS AS INDICATED BY ARROWS ONPLANS.X02LITHONIA#LQM S W 3 G 120/277 EL N SDELECTRONIC UNIVERSAL LED, GREEN N/A 2W N/A LED EXIT LIGHT (DOUBLE FACE). CHEVRONS AS INDICATED BY ARROWSON PLANS.X03LITHONIA#LQM S W 3 G 120/277 EL N SDELECTRONIC WALL, +12" LED, GREEN N/A 1W N/A LED EXIT LIGHT (SINGLE FACE, LOW MOUNT). MOUNT AT +12" FROM FLOOR,WITHIN 4" OF LATCH SIDE OF DOOR.X04Isolite#HZE EM G MB SDELECTRONIC UNIVERSAL LED, GREEN N/A 1W N/A LED EXIT LIGHT FOR WET LOCATIONS.Z01KLUS#K CR30 1220 24EXTRUSION: KLUS#45-ALULENS: HSPOWER SUPPLY,0-10V DIMMINGEXTRUSION INCOVELED, 3000K 215LM/FT 2.9W/FT 74 ACCENT LIGHT, LOBBY COVE, ORIENTED OUT FROM COVE. PROVIDELENGTHS AS SHOWN ON DRAWINGS SEE ARCHITECTURAL SHEET A-608FOR DETAILS. MOUNT POWER SUPPLY ABOVE NEAREST ACCESSIBLECEILING.Z02KLUS#K CR30 1220 24EXTRUSION: KLUS#KOPRO-30LENS: HSPOWER SUPPLY,0-10V DIMMINGEXTRUSION INCOVELED, 3000K 215LM/FT 2.9W/FT 74 LINEAR COVE LIGHTING - DRAPERY POCKET. ORIENTED TOWARD WINDOW.PROVIDE LENGTHS AS SHOWN ON DRAWINGS. SEE ARCHITECTURALSHEET A-608 FOR DETAILS. MOUNT POWER SUPPLY ABOVE NEARESTACCESSIBLE CEILING.Z03AXIS#SCS 300 90 27 FL ## AP UNV DP 1 S120-277V, 0-10VDIMMINGSURFACE INARCHITECTURALPOCKETLED, 2700K 300LM/FT 3.25W/FT 93 LINEAR ACCENT LIGHT, OVER BARS. SURFACE MOUNT TO LAMINATECEILING. PROVIDE LENGTHS AS SHOWN ON DRAWINGS. SEEARCHITECTURAL SHEETS A-702 AND A-703 FOR ADDITIONAL INFORMATION.Z04KLUS#K CR27 1220 24EXTRUSION: KLUS#MICRO-PLUSLENS: HSPOWER SUPPLY,0-10V DIMMINGEXTRUSION INCHANNELUNDER SHELFLED, 2700K 215LM/FT 2.9W/FT 74 LINEAR ACCENT LIGHT, LOWER SHELF/BACKSPLASH AT BARS SEEARCHITECTURAL SHEETS A-702 AND A-703 FOR MOUNTING LOCATIONS.COORDINATE WITH CASEWORK PROVIDER FOR POWER SUPPLYMOUNTING.Z05KLUS#K CR27 1220 24EXTRUSION: KLUS#MICRO-PLUSLENS: HSPOWER SUPPLY,0-10V DIMMINGEXTRUSION INRECESSEDBANQUETTECAVITYLED, 2700K 215LM/FT 2.9W/FT 74 LED ACCENT UPLIGHT, MOUNTED IN BANQUETTE BENCH. PROVIDE LENGTHAS SHOWN ON PLANS. SEE ARCHITECTURAL SHEETS FOR MOUNTINGDETAILS. COORDINATE WITH BANQUETTE PROVIDER FOR POWER SUPPLYMOUNTING.32 MERCHANT STREET, SUITE 208HONOLULU, HI 96813808-352-5299OWNER:HOMEWOOD SUITES by HILTON
SPOKANE VALLEY, WA
13515 E. Carlisle Avenue
Spokane Valley, WA 99216FSC PROJECT NO. 21012PERMITDOCUMENTSMay 31, 2024GL8 MirabeauPoint, LLCTMK:PID: 45101.0401 10909 E. Pierce LaneSpokane, WA 99206(509) 919-0901Revision ScheduleNumber Description Date5915 S REGAL STREETSUITE 201SPOKANE, WA 99223PH: 509.473.9218Kelly@kwrllc.comwww.kwrllc.com5/30/2024 12:49:06 PMSTATE OF WASHINGTONREGISTERED PROFESSIONAL ENG
INEER48350 KELLY A
N
DREW WATERMAN05.31.24LUMINAIRESCHEDULESE-004
DLLCM1BRDGGTWY12678LDM1LDMVOSPS1PS2RCMCONTROL DEVICE SCHEDULESYMBOLDESCRIPTIONPRODUCTNOTES / SOODAYLIGHT SENSORNLIGHT #NCM ADCXPROVIDE NETWORK LEVEL PHOTOCELL. PHOTOCELL TO CONTROL DAYLIGHT ZONES AS INDICATED BY LOWERCASE LETTERSBEGINNING WITH 'DZ'. IF NO ZONE LETTERS ARE INDICATED, THE DAYLIGHT SENSOR CONTROLS THE LIGHTS IN BOTH THEPRIMARY AND SECONDARY DAYLIGHT ZONES FOR WHICH THE SENSOR IS LOCATED. CONNECT DAYLIGHT SENSOR TO LOCALDIGITAL LIGHTING CONTROL NETWORK VIA CAT-5E NETWORK CABLE (PLENUM RATED).LIGHTING CONTROL MODULENLIGHT #NPP16(1) RELAYPROVIDE LIGHTING CONTROL MODULE TO CONTROL LIGHTING ZONES AS INDICATED. CONNECT MODULE TO LOCALDISTRIBUTED, DIGITAL LIGHTING CONTROL NETWORK VIA CAT-5E CABLING PER MANUFACTURER'S RECOMMENDATIONS.CONNECT LINE SIDE OF MODULE TO UNSWITCHED CIRCUIT, AND EXTEND LOAD SIDE SWITCHED CONDUCTORS TO LIGHTINGZONES AS INDICATED. NETWORK CABLE HOMERUNS SHALL TERMINATE AT NEAREST NETWORK BRIDGE.LIGHTING CONTROL NETWORK BRIDGENLIGHT #NBRG 88-PORT LIGHTING CONTROL NETWORK BRIDGEPROVIDE NETWORK BRIDGES AS REQUIRED TO ACCEPT CABLING HOMERUNS FROM LOCAL DISTRIBUTED LIGHTING CONTROLNETWORK HOMERUNS. PROVIDE BRIDGE POWER SUPPLY, NLIGHT PS150, TO SUPPLY BUS POWER WHERE A LIGHT DIMMINGMODULE/POWER PACK IS NOT PRESENT. PROVIDE BRIDGES AT REQUIRED TO CONNECT AREA TO ASSOCIATED GATEWAYHEAD END. ACTUAL QUANTITY AND LOCATION OF BRIDGES NOT SHOWN, AND SHALL BE PROVIDED IN MANUFACTURER SHOPDRAWINGS.LIGHTING CONTROL NETWORK GATEWAYNLIGHT SYSTEM CONTROLLER#NECY-24-BAC-ENC-GFXKNLIGHT GRAPHIC USER INTERFACE #NGWY2-GFXNLIGHT POWER SUPPLY #PS 150PROVIDE LIGHTING SYSTEM CONTROLLER AND GRAPHIC USER INTERFACE IN FACTORY NEMA 1 ENCLOSURE (NLIGHT#ENCNE1). PROVIDE POWER SUPPLY #PS 150. CONNECT GATEWAY TO BRIDGE HUB VIA CAT-5E CABLE. CONNECT GATEWAY TOLOCAL AREA NETWORK VIA CAT-5E CABLE. INTEGRAL ASTRONOMICAL TIME CLOCK FOR PROGRAMMABLE AUTOMATIC TIMEBASED CONTROL OF ALL NON-OCCUPANCY BASED CONTROL ZONES. COORDINATE TIME SCHEDULE FOR EACH INDIVIDUALZONE WITH OWNER DURING START-UP.DIGITAL LIGHTING CONTROL STATIONNLIGHT #NPODM DX1-POLE ON/OFF, RAISE/LOWER CONTROLSTATIONPROVIDE ON/OFF, RAISE/LOWER FOR CONTROLLED LIGHTING ZONE AS INDICATED ON THE DRAWINGS. LOWER CASE LETTERSDENOTE ZONES TO BE CONTROLLED. SWITCHES WITHOUT ZONE DESIGNATIONS CONTROL A SINGLE ZONE IN THE SPACE INWHICH THEY ARE INSTALLED.DIGITAL LIGHTING CONTROL STATIONNLIGHT #NPODM 2P DX2-POLE ON/OFF, RAISE/LOWER CONTROLSTATIONPROVIDE 2-POLE ON/OFF, RAISE/LOWER FOR CONTROLLED LIGHTING ZONE AS INDICATED ON THE DRAWINGS. LOWER CASELETTERS DENOTE ZONES TO BE CONTROLLED. CONNECT CONTROL STATION TO LOCAL LIGHTING CONTROL NETWORK BUSVIA CAT-5E CABLE.NETWORK LEVEL OCCUPANCY SENSORCONTROL STATION COMBINATION DEVICENLIGHT #NWSX LV DX1-POLE ON/OFF, OCCUPANCY SENSOR,RAISE/LOWER CONTROL STATIONPROVIDE NETWORK LEVEL DIGITAL WALL SWITCH OCCUPANCY SENSOR COMBINATION DEVICE WITH ON/OFF AND RAISELOWER BUTTONS FOR MANUAL CONTROL OF LIGHTING ZONES INDICATED. CONNECT CONTROL STATION / SENSOR DEVICE TOLOCAL LIGHTING CONTROL NETWORK DEVICES (I.E. LDM1) VIA CAT-5E NETWORK CABLE.KEYED DIGITAL LIGHTING CONTROL STATION NLIGHT #NPOD KEYPROVIDE 1-POLE ON/OFF KEYED CONTROL STATION FOR MANUAL OVERRIDE OF ZONE INDICATED. CONNECT CONTROLSTATION TO LOCAL LIGHTING CONTROL NETWORK BUS VIA CAT-5E CABLE.GRAPHIC LIGHTING CONTROL STATIONNLIGHT #NPOD GFX16-ZONE, 8-SCENE GRAPHIC LIGHTING CONTROLSTATIONPROVIDE 8 SCENE DIGITAL CONTROL STATION. PROVIDE SCENE PROGRAMMING AS DESIRED BY OWNER PRIOR TO PROJECTCLOSEOUT. RAISE/LOWER BUTTONS SHALL ADJUST THE DEFAULT LIGHT LEVEL OF THE SELECTED SCENE, PROPORTIONATELYTO THE SCENE.LIGHT DIMMING MODULENLIGHT #NPP16D(1) RELAY AND (1) 0-10V CLASS 1 DIMMINGOUTPUTPROVIDE LIGHTING CONTROL/DIMMING MODULE TO CONTROL LIGHTING ZONES AS INDICATED. CONNECT LIGHTING CONTROLMODULE TO LOCAL DISTRIBUTED, DIGITAL LIGHTING CONTROL NETWORK VIA CAT-5E CABLING PER MANUFACTURERSRECOMMENDATIONS. CABLING TO BE PLENUM RATED. CONNECT LINE SIDE OF MODULE TO UNSWITCHED CIRCUIT, ANDEXTEND LOAD SIDE SWITCHED CONDUCTORS AND CLASS 1 DIMMING CIRCUIT (2#16) TO LIGHTING ZONES AS INDICATED.NETWORK CABLE HOMERUNS SHALL TERMINATE AT NEAREST NETWORK BRIDGE.LIGHT DIMMING MODULE - ELV/MLVNLIGHT #NSP5-PCD(1) SECONDARY RELAY AND DIMMING PACK (ELV)PROVIDE LIGHTING CONTROL/DIMMING MODULE TO CONTROL LIGHTING ZONES AS INDICATED. MODULE SUITABLE FORELECTRONIC LOW VOLTAGE AND MAGNETIC LOW VOLTAGE DIMMING LOADS. CONNECT LIGHTING CONTROL MODULE TO LOCALDISTRIBUTED, DIGITAL LIGHTING CONTROL NETWORK VIA CAT-5E CABLING PER MANUFACTURER'S RECOMMENDATIONS.CABLING TO BE PLENUM RATED WHERE INSTALLED IN PLENUM SPACE. CONNECT LINE SIDE OF MODULE TO UNSWITCHEDCIRCUIT, AND EXTEND LOAD SIDE SWITCHED CONDUCTORS TO LIGHTING ZONES AS INDICATED. NETWORK CABLE HOMERUNSSHALL TERMINATE AT NEAREST NETWORK BRIDGE.WIRELESS LIGHTING CONTROL ANTENNANLIGHT #NECYD NLTAIRPROVIDE WIRELESS LIGHTING CONTROL ANTENNA WITH USB PATCH CABLE TO CONNECT TO HEAD END SYSTEM CONTROLLER('GTWY'). VERIFY MOUNTING LOCATION WITH MANUFACTURER FOR COMMUNCATION WITH SITE POLES AS SHOWN ON SITEPLAN. VERIFY USB CABLE LENGTH, PROVIDE EXTENDER AND POWER SUPPLY AS REQUIRED TO CONNECT ANTENNA TO GTWY.OCCUPANCY SENSORNLIGHT #NCM PDTCEILING-MOUNTED NETWORK OCCUPANCYSENSORPROVIDE DUAL TECHNOLOGY, NETWORK LEVEL OCCUPANCY SENSOR, CAPABLE OF DETECTING SMALL MOTION. OCCUPANCYSENSOR TO CONTROL ZONE(S) AS INDICATED BY LOWERCASE LETTERS. WHERE NO LETTER IS INDICATED, OCCUPANCYSENSOR TO CONTROL ALL ZONES IN THAT SPACE. CONNECT OCCUPANCY SENSOR TO DIGITAL LIGHTING CONTROL NETWORKVIA CAT-5E NETWORK CABLE. OCCUPANCY SENSORS SHALL BE CONFIGURED TO OPERATE IN 'VACANCY' MODE: MANUAL ON /AUTO OFF.POWER SUPPLYKLUS#010-96-2424VDC POWER SUPPLY FOR UP TO 96W WITH 0-10V DIMMING FOR TYPE LED TAPE ACCENT LIGHTS. CONNECT LINE SIDE TOADJACENT LIGHTING DIMMING MODULE SWITCH LEG AND 0-10V DIMMING CIRCUIT. PROVIDE 24V CIRCUIT FROM LOAD SIDE TOLOW VOLTAGE ACCENT LIGHTS VIA FACTORY CONNECTORS AND WIRING HARNESS. FIELD COORDINATE MOUNTING INNEAREST ACCESSIBLE CEILING OR IN CASEWORK WHERE APPLICABLE.POWER SUPPLYWAC LIGHTING#9150-TRN-SS12VDC MAGNETIC POWER SUPPLY FOR UP TO 150W FOR TYPE W06 ACCENT SCONCES. CONNECT LINE SIDE TO ADJACENTLIGHTING DIMMING MODULE SWITCH LEG. PROVIDE12V CIRCUIT FROM LOAD SIDE TO LOW VOLTAGE ACCENT LIGHTS VIAFACTORY CONNECTORS AND WIRING HARNESS. ONE POWER SUPPLY PER (2) COLUMNS / (8) FIXTURES.RECEPTACLE CONTROL MODULENLIGHT #NPP20 PL(1) RELAY PLUG LOAD CONTROLLERPROVIDE RECEPTACLE CONTROL MODULE TO CONTROL RECEPTACLE LOADS AS INDICATED BY SYMBOL. CONNECT CONTROLMODULE TO LOCAL DISTRIBUTED, DIGITAL LIGHTING CONROL NETWORK VIA CAT-5E CABLING PER MANUFACTURERSRECOMMENDATIONS. RECEPTACLE CONTROLLER TO BE CONNECTED AS PART OF THE LOCAL LIGHTING CONTROL NETWORK.NETWORK CABLE HOMERUNS SHALL TERMINATE AT NEAREST NETWORK BRIDGE.LINE VOLTAGE WALL SWITCHLOWERCASE LETTER SUBSCRIPTS INDICATE NUMBER OF POLES/BUTTONS. EACH LETTER REPRESENTS A ZONES OF CONTROL(I.E. SUBSCRIPT 'ab' INDICATES A 2-POLE, 2-BUTTON WALL SWITCH)OCCUPANCY SENSOR WALL SWITCHSENSOR SWITCH#WSX-D (FOR SINGLE ZONE DIMMING)PROVIDE LINE-VOLTAGE WALL SWITCH OCCUPANCY SENSOR WITH 0-10V DIMMING CAPABILITY. CONNECT UNSWITCHED HOTTO LINE SIDE OF DEVICE AND EXTEND SWITCH LEG AND 0-10V DIMMING CIRCUIT TO LUMINAIRES IN THE ROOM.GUEST UNIT LUMINAIRE SCHEDULETYPESYMBOLMFGR & CATALOG NUMBERDRIVERMOUNTING LIGHTSOURCELUMENOUTPUTINPUTWATTSLUMENS/WATTNOTESG.B06ALPHABET#NU6RD SW 15LM 27K 80 HE60 WH WH NC 120 ELV1120VRECESSED LED, 2700K 1200LM 14W 86 GUEST UNIT 6" RECESSED DOWNLIGHT.NON-CONDUCTIVE TRIM FOR SHOWER INSTALLATION.G.F01REMINGTON LIGHTING#STYLE 15304120VSURFACE (3) E26 LEDREPLACEMENT,2700K-30WMAX(10WLAMPS)- GUEST UNIT SURFACE LIGHTG.P01REMINGTON LIGHTING#STYLE 15303120-277VPENDANT,+6'-0"(1) E26 LEDREPLACEMENT,2700K-15WMAX- GUEST UNIT DECORATIVE PENDANTG.W01WAC LIGHTING#WS-W61806-BK120VWALL, +6'-0" LED, 3000K 773LM 9W 86 GUEST UNIT WALL SCONCE, WET LOCATION RATED(BALCONY)G.Z24JUNO#UCES 24IN SWW6 90CRI WH M6120VUNDERCABINETSURFACELED, 3000K 825LM 11W 75 GUEST UNIT UNDERCAB LIGHTING. FIELD SET COLORTEMPERATURE TO 3000K32 MERCHANT STREET, SUITE 208HONOLULU, HI 96813808-352-5299OWNER:HOMEWOOD SUITES by HILTON
SPOKANE VALLEY, WA
13515 E. Carlisle Avenue
Spokane Valley, WA 99216FSC PROJECT NO. 21012PERMITDOCUMENTSMay 31, 2024GL8 MirabeauPoint, LLCTMK:PID: 45101.0401 10909 E. Pierce LaneSpokane, WA 99206(509) 919-0901Revision ScheduleNumber Description Date5915 S REGAL STREETSUITE 201SPOKANE, WA 99223PH: 509.473.9218Kelly@kwrllc.comwww.kwrllc.com5/30/2024 12:49:11 PMSTATE OF WASHINGTONREGISTERED PROFESSIONAL ENG
INEER48350 KELLY A
N
DREW WATERMAN05.31.24LUMINAIRESCHEDULESE-005
S02S02S02S02S03-2S03-2S03-2S03-2S02S03S03S02S02S02EXISTING UTILITYPRIMARY JUNCTIONENCLOSUREUG/E UG/E UG/E UG/E UG/E UG/E UG/E UG/E UG/E UG/E UG/E UG/E UG/E UG/E UG/E UG/E UG/E UG/EUG/EUG/EUG/E124356EV-1EV-21E-104UTILITY TRANSFORMEREV-1,3EV-5,7ATS-YUG/EH11-1H11-1H11-1H11-1H11-1H11-3H11-3H11-3H11-3H11-3H11-3H11-3H11-3H11-3NEW BUILDINGext1ext1ext1ext1ext1ext1ext1ext1ext1ext1ext1ext1ext1S12S12H11-1H11-1ext2ext2FP-1FP-2FP-3WPMONUMENT SIGNWPDRIVEWAY SIGNWPDRIVEWAY SIGNHH7HH7HH7999888L12-15L12-17L12-17L12-17L12-19L12-19HHHHHHHHHHHHHH10101010101010HHUG/T UG/T UG/T UG/T UG/T UG/T UG/T UG/T UG/T UG/T UG/T HHUG/T1111 GEN-YUTILITY METERMSB1E-102TYP2E-102TYP1E-1032 / 3E-10332 MERCHANT STREET, SUITE 208HONOLULU, HI 96813808-352-5299OWNER:HOMEWOOD SUITES by HILTON
SPOKANE VALLEY, WA
13515 E. Carlisle Avenue
Spokane Valley, WA 99216FSC PROJECT NO. 21012PERMITDOCUMENTSMay 31, 2024GL8 MirabeauPoint, LLCTMK:PID: 45101.0401 10909 E. Pierce LaneSpokane, WA 99206(509) 919-0901Revision ScheduleNumber Description Date5915 S REGAL STREETSUITE 201SPOKANE, WA 99223PH: 509.473.9218Kelly@kwrllc.comwww.kwrllc.com5/30/2024 12:49:19 PMSTATE OF WASHINGTONREGISTERED PROFESSIONAL ENG
INEER48350 KELLY A
N
DREW WATERMAN05.31.24ELECTRICAL SITEPLANE-101SCALE:1" = 25'-0"ELECTRICAL SITE PLANGENERAL NOTESA. COORDINATE ALL ELECTRICAL UTILITY WORK WITH AVISTA UTILITIES.IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO ADHERE TO THEPUBLISHED DOCUMENTS AND STANDARDS OF THE SERVINGELECTRICAL UTILITY. CONTRACTOR TO PROVIDE NEW VAULT,TRANSFORMER VAULT AND PAD, AND RACEWAY FOR PRIMARY ANDSECONDARY SERVICE CONDUCTORS. CONTACT:TODD HARMON, (509) 503-8094, todd.harmon@avistacorp.comB. THIS PLAN MAY NOT SHOW ALL EXISTING BURIED UTILITIES.CONTACT UNDERGROUND LOCATION SERVICE PRIOR TOEXCAVATION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALLCOSTS ASSOCIATED WITH UNDERGROUND LOCATING AND ANYREPAIRS FROM FAILING TO TAKE NECESSARY PRECAUTIONS PRIORTO EXCAVATION.C. UNDERGROUND RACEWAY SHALL BE PLACED MINIMUM 24" BELOWFINISH GRADE. UNDERGROUND UTILITY CONDUIT SHALL BE PLACED36" BELOW FINISH GRADE, OR AS DIRECTED BY THE SERVINGUTILITY.D. ALL SITE BRANCH CIRCUITS SHALL BE 1"C,3#10,#10G UNLESSOTHERWISE NOTED.E. SEE SHEETS E-201A AND E-201B FOR EXTERIOR LIGHTING CONTROLMODULE LOCATIONS.F. DESIGN INTENT FOR EXTERIOR LIGHTING CONTROL ZONES 'ext1' AND'ext2' IS WIRELESS CONTROL VIA INTEGRAL CONTROL MODULES. SEESHEET E-201A FOR ANTENNA LOCATION. SITE POLES SHALL BEENERGIZED FROM DUSK TO DAWN. POLES SHALL DIM BY 50% WHENNO MOTION IS DETECTED FOR 15 MINUTES.FLAG NOTESNEW UTILITY TRANSFORMER FOR PERMANENT SERVICE EQUIPMENT.CONTRACTOR TO PROVIDE CONCRETE PAD, EXCAVATION, ANDMETER ENCLOSURE, UTILITY TO PROVIDE TRANSFORMER ANDPRIMARY AND SECONDARY CONNECTIONS. COORDINATESCHEDULING AND INSTALLATION WITH SERVING UTILITY. PROVIDECONCRETE FILLED STEEL BOLLARDS FOR TRAFFIC PROTECTION ASREQUIRED BY UTILITY.PROVIDE TRENCHING AS REQUIRED TO INTERCEPT EXISTING AVISTAUNDERGROUND PRIMARY IN THIS APPROXIMATE LOCATION, FORROUTING TO NEW UTILITY TRANSFORMER. VERIFY EXACT LOCATIONAND REQUIREMENTS WITH AVISTA UTILITIES PRIOR TOCOMMENCEMENT OF WORK.PROVIDE SECONDARY TRENCHING, CONDUIT, CONDUCTORS ANDBACKFILL. SEE ONE-LINE DIAGRAM FOR ADDITIONAL INFORMATION.LOCATION OF MAIN SERVICE EQUIPMENT / MAIN DISCONNECT,SHOWN FOR REFERENCE. SEE SHEET E-501 FOR EXACT LOCATION.NEW LEGALLY REQUIRED STANDBY, NATURAL GAS GENERATOR INWEATHERPROOF SOUND ATTENUATING ENCLOSURE. COORDINATEFINAL EXACT LOCATION WITH OWNER AND ARCHITECT PRIOR TOROUGH-IN. GENERATOR AND ASSOCIATED FUEL CONNECTION SHALLMAINTAIN MINIMUM 10' CLEARANCE FROM UTILITY TRANSFORMER.PROVIDE CONCRETE PAD AND DEDICATED GROUNDING ELECTRODESYSTEM PER DETAILS ON SHEETS E-102 AND E-701. SEE ONE-LINEDIAGRAM AND SPECIFICATIONS FOR ADDITIONAL SIZING ANDINFORMATION. EMERGENCY STOP BUTTON SHALL BE MOUNTEDDIRECTLY TO GENERATOR ENCLOSURE.NEW UNDERGROUND FEEDER FROM GENERATOR. SEE ONE-LINEDIAGRAM ON SHEET E-601 FOR ADDITIONAL INFORMATION.PROVIDE HANDHOLE ADJACENT TO INTERNALLY LIT MONUMENT /DRIVEWAY ENTRY SIGNS. PROVIDE HANDHOLE FOR ROUTINGBRANCH CIRCUIT.ROUTE BRANCH CIRCUIT VIA CONTROL MODULE SHOWN ON SHEETE-501 FOR TIME-CLOCK CONTROL. SEE SHEET E-501 FORADDITIONAL INFORMATION.PROVIDE 120V BRANCH CIRCUIT FOR FLAGPOLE LIGHT. LIGHT ISINTEGRAL TO FLAGPOLE, MOUNTED AT TOP OF POLE. COORDINATEWITH POLE INSTALLER FOR WIRING REQUIREMENTS. FLAGPOLELIGHT CONTAINS INTEGRAL DAYLIGHT SENSOR FOR CONTROLS.PROVIDE HANDHOLE WITH (2)1"C ROUTED TO PANEL EV IN MAINELECTRICAL ROOM, FOR FUTURE EV CHARGING CIRCUITS.PROVIDE (2)2"C FROM STREET-SIDE INFRASTRUCTURE INTOBUILDING FOR ISP SERVICE CABLING. COORDINATE WITH OWNERSELECTED ISP FOR EXACT ROUTING AND REQUIREMENTS.ROUTING/LOCATIONS SHOWN ARE PRELIMINARY. ROUTE CONDUITSTO PBX/MDF ROOM ON SECOND FLOOR, SHOWN ON SHEET E-302A1234567891011
DETAIL NOTES:1. CONCRETE TO MEET DIVISION 3SPECIFICATIONS (033000).CONCRETE 30 DAY STRENGTH6000-7000 PSI.2. BASIS OF DESIGN IS BASED ONPRE-CAST BASE.3. PROVIDE 1" PVC COUPLINGS ASREQUIRED FOR RACEWAYS SHOWN.HOMERUN OR NEXT POLETO NEXT POLEFINISHED GRADELIGHT POLE3"x5" HAND HOLE WITHTAMPER RESISTANT SCREWS2-PIECE BOLT COVER PLATE1" CHAMFERSMOOTH SURFACEANCHOR BOLTS PER POLEMANUFACTURER'SREQUIREMENTSREBAR, #3 HOOPS @ 12" O.C.,#5 VERTICAL, 4 PIECES(4) 1" PVC SCH. 40 CONDUIT1" PVC COUPLERUNDISTURBED SOIL ORSELECT BACKFILL COMPACTED30"72"24" MIN18" ROUND CONCRETE BASE24"LIGHT POLE3"x 5" HAND HOLE WITHTAMPER RESISTANT SCREWS2-PIECE BOLD COVER PLATE1" CHAMFERSMOOTH SURFACEFINISHED GRADEANCHOR BOLTS PER POLEMANUFACTURER'S REQUIREMENTS(4) 1" PVC SCH. 40 CONDUIT1" PVC COUPLERUNDISTURBED SOIL OR SELECTBACKFILL COMPACTED.REBAR, #3 HOOPS AT 12" O.C.,#5 VERTICAL, 4 PIECESCONCRETE MOW STRIPHOMERUN OR NEXT POLE24" ROUND CONCRETE BASE72"6"
24" MIN
TO NEXT POLEDETAIL NOTES:1. CONCRETE TO MEET DIVISION 3SPECIFICATIONS (033000).CONCRETE 30 DAY STRENGTH6000-7000 PSI.2. BASIS OF DESIGN IS BASED ONPRE-CAST BASE.3. PROVIDE 1" PVC COUPLINGS ASREQUIRED FOR RACEWAYS SHOWN.18"(2) 3/8-16 UNCSTAINLESS STEEL HEXHEAD BOLT W/WASHER1/2" x 2" PULL SLOT.5 COF SKID RESISTANTSURFACE(2) 2-1/2" x 4"MOUSEHOLESBACKFILL4" WIDE YELLOWMARKING TAPEGRADE12"
30"3/4" MINUS GRAVEL BED,CONDUITS WHERE NECESSARYIN ROCKY AREAS, OTHERWISEUSE SELECTED NATURAL FILLSCHEDULE 40 PVCCONDUIT, SIZE/QUANTITYAS NOTED ON PLANSNO SPLICESIN J-BOXQUAZITE FLUSH IN-GRADEPOLYMER ENCLOSUREPHASE CONDUCTORS ORCABLING AS REQUIREDBUSHING (TYPICAL)4" MINIMUMINCOMING ANDOUTGOINGCONDUITS, SIZE ASNOTED ON PLANSPROVIDE 3/4" MINUS GRAVEL 6"DEEP BELOW AND 6" BEYONDALL SIDES OF PULL BOXFLUSH IN-GRADE POLYMER LID(2) 3/8-16 UNCSTAINLESS STEEL HEXHEAD BOLT W/WASHER1/2" x 2" PULL SLOT.5 COF SKID RESISTANTSURFACE(2) 2-1/2" x 4"MOUSEHOLESDETAIL NOTES:1. CONCRETE TO MEET DIVISION 3SPECIFICATIONS (033000).CONCRETE 30 DAY STRENGTH6000-7000 PSI.2. BASIS OF DESIGN IS BASED ONPRE-CAST BASE.3. PROVIDE 1" PVC COUPLINGS ASREQUIRED FOR RACEWAYS SHOWN.HOMERUN OR NEXT POLETO NEXT POLEFINISHED GRADEBOLLARD LUMINAIREANCHOR BOLTS PER POLEMANUFACTURER'SREQUIREMENTSREBAR, #3 HOOPS @ 12" O.C.,#5 VERTICAL, 4 PIECES(2) 1" PVC SCH. 40 CONDUIT1" PVC COUPLERUNDISTURBED SOIL ORSELECT BACKFILL COMPACTED48"
24" MIN12" ROUND CONCRETE BASE12"32 MERCHANT STREET, SUITE 208HONOLULU, HI 96813808-352-5299OWNER:HOMEWOOD SUITES by HILTON
SPOKANE VALLEY, WA
13515 E. Carlisle Avenue
Spokane Valley, WA 99216FSC PROJECT NO. 21012PERMITDOCUMENTSMay 31, 2024GL8 MirabeauPoint, LLCTMK:PID: 45101.0401 10909 E. Pierce LaneSpokane, WA 99206(509) 919-0901Revision ScheduleNumber Description Date5915 S REGAL STREETSUITE 201SPOKANE, WA 99223PH: 509.473.9218Kelly@kwrllc.comwww.kwrllc.com5/30/2024 12:49:28 PMSTATE OF WASHINGTONREGISTERED PROFESSIONAL ENG
INEER48350 KELLY A
N
DREW WATERMAN05.31.24ELECTRICAL SITEDETAILSE-102SCALE:1SITE POLE BASE DETAIL (TYPES S02, S03)NTSSCALE:2FLUSH POLE BASE DETAIL (TYPE S12)NTSSCALE:4TRENCHING AND IN-GRADE HANDHOLD DETAILNTSSCALE:3LIT BOLLARD MOUNTING DETAIL (TYPE S21)NTS
3' MIN 3' MIN3' MIN10' MINTOP VIEWPAD-MOUNT EQUIPMENTACCESS DOORSCOOLING FINSPAD MOUNT TRANSFORMER TYPICAL CLEARANCESNOTES:1. DETAIL IS DIAGRAMMATIC; NOT ALL SCOPE IS SHOWN.2. DIMENSIONS ARE TYPICAL; VERIFY ALL DIMENSIONS AND INSTALLATION REQUIREMENTS WITH UTILITY REPRESENTATIVEPRIOR TO COMMENCEMENT OF WORK3. PROVIDED CONCRETE-FILLED STEEL BOLLARDS AS REQUIRED BY UTILITY. VERIFY QUANTITY AND SPACING PRIOR TOINSTALLATION.4. CONDUIT QUANTITIES AND SIZES SHOWN ARE DIAGRAMMATIC. PROVIDE ALL CONDUITS AS NOTED ON ONE-LINE DIAGRAMAND AS REQUIRED BY UTILITY.5. PROVIDE CT CONDUIT, MOUNTING EQUIPMENT, AND ENCLOSURE ONLY WHERE SHOWN ON SITE PLANHLC8"BAPVC CONDUIT SWEEPSCUSTOMER PVCCONCRETETRANSFORMER PAD6" MAXIMUM FROMBACK OF OPENING ONCUSTOMER SIDETRANSFORMER PAD (TOP VIEW)NOTES:1. DETAIL IS REFERENCED FROM AVISTA 'BLUE BOOK'. REFER TO AVISTA PUBLISHED STANDARDS AND COORDINATE WITHPROJECT COORDINATOR FOR FINAL REQUIREMENTS.2. DETAIL IS DIAGRAMMATIC; NOT ALL SCOPE IS SHOWN.3. DIMENSIONS ARE TYPICAL; VERIFY ALL DIMENSIONS AND INSTALLATION REQUIREMENTS WITH UTILITY REPRESENTATIVEPRIOR TO COMMENCEMENT OF WORK4. CONDUIT QUANTITIES AND SIZES SHOWN ARE DIAGRAMMATIC. PROVIDE ALL CONDUITS AS NOTED ON ONE-LINE DIAGRAMAND AS REQUIRED BY UTILITY.5. PROVIDE CT CONDUIT, MOUNTING EQUIPMENT, AND ENCLOSURE ONLY WHERE SHOWN ON SITE PLAN12" MIN15' MAXMAINTAIN 3" CLEARANCEFROM OTHER OPENINGS ANDINSTALLED CONDUCTORS4"
6" MAX
HIGHVOLTAGE SIDELOWVOLTAGE SIDEGROUND SLEEVEFINISH GRADETRANSFORMER PAD (SIDE VIEW)NOTES:1. DETAIL IS REFERENCED FROM AVISTA 'BLUE BOOK'. REFER TO AVISTA PUBLISHED STANDARDS AND COORDINATE WITHPROJECT COORDINATOR FOR FINAL REQUIREMENTS.24"NEW GENERATORSTEEL REINFORCEMENT BARSSHALL BE #4 BARS, NOT TOEXCEED 12" SPACING.36"36"12" MIN
8" MINDETAIL NOTES:1. SLAB DESIGN SHOWN IS INTENDED TO SHOW DIMENSIONS AND GENERAL DESIGN INTENT. CONTRACTOR SHALL PROVIDESTRUCTURAL CONCRETE PAD, STRUCTURALLY DESIGNED TO SUPPORT THE ENTIRE GENERATOR ASSEMBLY. SUBMIT SHOPDRAWINGS AND STRUCTURAL CALCULATIONS FOR REVIEW PRIOR TO POURING CONCRETE PAD.2. COORDINATE WITH GENERATOR MANUFACTURER AND MECHANICAL CONTRACTOR FOR ALL SLAB PENETRATIONS FOR FEEDERCONDUITS, CONTROLS CONDUITS, AND ALL NATURAL GAS LINE REQUIREMENTS.3. PROVIDE 1"C TO GENERATOR ACCESSORY FOR CONTROL WIRING PER MANUFACTURER ELECTRICAL REQUIREMENTS. COORDINATEFINAL QUANTITY OF GENERATOR ACCESSORIES WITH MANUFACTURER PRIOR TO ROUGH-IN.24" MIN4"C TO ATS1"C TO ATS FOR CONTROL WIRING1"C TO GENERATOR ANNUNCIATOR1"C TO GENERATOR EPO1"C TO GENERATOR ACCESSORY 11"C TO GENERATOR ACCESSORY 21"C TO GENERATOR ACCESSORY 31"C TO GENERATOR ACCESSORY 41"C TO GENERATOR ACCESSORY THATMAY DIFFER PER MANUFACTURER.32 MERCHANT STREET, SUITE 208HONOLULU, HI 96813808-352-5299OWNER:HOMEWOOD SUITES by HILTON
SPOKANE VALLEY, WA
13515 E. Carlisle Avenue
Spokane Valley, WA 99216FSC PROJECT NO. 21012PERMITDOCUMENTSMay 31, 2024GL8 MirabeauPoint, LLCTMK:PID: 45101.0401 10909 E. Pierce LaneSpokane, WA 99206(509) 919-0901Revision ScheduleNumber Description Date5915 S REGAL STREETSUITE 201SPOKANE, WA 99223PH: 509.473.9218Kelly@kwrllc.comwww.kwrllc.com5/30/2024 12:49:32 PMSTATE OF WASHINGTONREGISTERED PROFESSIONAL ENG
INEER48350 KELLY A
N
DREW WATERMAN05.31.24ELECTRICAL SITEDETAILSE-103SCALE:2AVISTA TRANSFORMER CLEARANCE DETAILNO SCALESCALE:3AVISTA TRANSFORMER DETAILNO SCALESCALE:1GENERATOR MOUNTING PAD DETAILNTS
001OUTDOORSTORAGE002OPEN TRASHENCLOSUREC96C96EOD-1J1LSSLSS-2,4LSS-1LSS-1LSS-3LSS-3LSS-3LSS-3UH-02LSS-5,7+44"+44"+44"+44"232 MERCHANT STREET, SUITE 208HONOLULU, HI 96813808-352-5299OWNER:HOMEWOOD SUITES by HILTON
SPOKANE VALLEY, WA
13515 E. Carlisle Avenue
Spokane Valley, WA 99216FSC PROJECT NO. 21012PERMITDOCUMENTSMay 31, 2024GL8 MirabeauPoint, LLCTMK:PID: 45101.0401 10909 E. Pierce LaneSpokane, WA 99206(509) 919-0901Revision ScheduleNumber Description Date5915 S REGAL STREETSUITE 201SPOKANE, WA 99223PH: 509.473.9218Kelly@kwrllc.comwww.kwrllc.com5/30/2024 12:49:36 PMSTATE OF WASHINGTONREGISTERED PROFESSIONAL ENG
INEER48350 KELLY A
N
DREW WATERMAN05.31.24STORAGE SHEDENLARGEDELECTRICAL PLANE-104GENERAL NOTESA. UNDERGROUND RACEWAY SHALL BE PLACED MINIMUM 24" BELOWFINISH GRADE. UNDERGROUND UTILITY CONDUIT SHALL BE PLACED36" BELOW FINISH GRADE, OR AS DIRECTED BY THE SERVINGUTILITY.B. ALL SITE BRANCH CIRCUITS SHALL BE 1"C,3#10,#10G UNLESSOTHERWISE NOTED.C. COORDINATE WITH MECHANICAL, PRIOR TO ROUGH-IN FOR FINALEQUIPMENT INSTALL LOCATIONS AND CONNECTIONSREQUIREMENTS.D. MAINTAIN 36" WORKING CLEARANCE IN FRONT OF ELECTRICALPANELS PER NEC REQUIREMENTS.FLAG NOTESPROVIDE 3/4"C AND CONTROL WIRING FROM ASSOCIATEDOVERHEAD DOOR OPERATOR TO JUNCTION BOX FOR MANUALCONTROL OF OVERHEAD DOOR. COORDINATE FINAL JUNCTION BOXLOCATION AND RACEWAY REQUIREMENTS WITH DOOR INSTALLERPRIOR TO ROUGH-IN.UNIT HEATER CONNECTION LOCATION IS PRELIMINARY. VERIFYEXACT LOCATION WITH MECHANICAL INSTALLER PRIOR TOROUGH-IN.1SCALE:1STORAGE SHED ELECTRICAL PLAN1/4" = 1'-0"2
533.16.12.1DC.1ECCBB18.1941.1AA78610W03W01W02W02ENEMA 4XNEMA 4XB22AEB22AW02B22AEB22AB22AER44R44R44R44C48EC48C48C48ER25B26B26B26B22AER27R27R27R27R27R27B25B25R251B25B25B25B25B25B20AB20AB20AR25E1dz1dz1dz2dz2LDM1LDM1dz1LDM1dz2R25R25ER25R25R25R25R25R25ER25R25B26B26B22AEP03P03B22B22B22AP03P03B22B22B26B26B22AEB22AR01-11R01-1111W24W24B22B22B22B22B22B221R26R26R26b,dz1b,dz2LDM1LDM1b,dz1LDM1b,dz2LDM1LDM1LDM1LDM1W01W01W01W01W01W01W02EW02W02G02EG02EG02EG02EGTWYW03EB06B06C96E BRDGC96
C96
C96EZ02aaaaaLDM1bb2abOSOSC48
OSOSOSOSOSOSX01X01X01X01X04OSOSOSB06EB06B06EB06B06B06EB06B06B06EB06B06EB06B06EB06B06B06E1TYP23455B20AB20A4X01X016dz1dz1dz2dz2DLdz1dz2DLdz1dz2LDM1LDM1dz1LDM1dz2W03DLdz1dz2aaB25C48W04W04W04W04W04W04W04W04W04W04W04W0411OSLDM1 7W48EW48Eext4ext4ext4ext5ext5ext5ext5ext5ext5S21S21S21S21S21S21S21S21S21S21S21S21S21ext10ext10ext10ext10ext10ext10ext10ext10ext10ext10ext10ext10B22 B2233aaR08B21EB21
B21EG01EG01EG01EH11LDM1LDMV
H11-5H11-5H11-5 H11-5H11-5H11-5H11-5
H11-5H11-5H11-5H11-5H11-5H11-5H11-5H11-5X04S21ext10S21ext10S21ext10H11-7
H11-7
H11-7H11-7H11-7H11-7H11-7H11-7H11-7H11-7H11-7H11-7H11-7H11-7H11-7H11-7H11-7H11-7H11-7H11-7H11-7H11-7H11-7H11-7H11-7H11-7H11-7H11-7H11-7 H11-9H11-9H11-9ELEV-5ELEV-5ELEV-5ELEV-5H11-7H11-7H11-7H11-7H11-7H11-7H11-7H11-7H11-7H11-7H11-7H11-7H11-7H11-7H11-7PS1PS1PS1H11-11 H11-11H11-11H11-11H11-11H11-11H11-11H11-11H11-11H11-11H11-11H11-11H11-11H11-11H11-11H11-11H11-11H11-11H11-11H11-11H11-11H11-11H11-11H11-11H11-11H11-11H11-11H11-11H11-11H11-11L12-36L12-36L12-36L12-36L12-36L12-36H11-7H11-7H11-7H11-7H11-7H11-7H11-7H11-7H11-7H11-7H11-7H11-7H11-7H11-7H11-7H11-7H11-7H11-7H11-7H11-7H11-7H11-7H11-7 H11-7H11-7H11-7H11-7H11-7L12-36L12-36L12-36L12-36L12-36H11-7H11-7H11-5 H11-5bbbLDMVLDMVbbbbbbbbbbbbH11-5H11-5a
H11-5+8'-0"104ELECTRICAL101POOL/SPLASHPAD102POOL RESTROOM100PUBLIC CORRIDOR108WATER HEATER& FIRE105BOH LAUNDRY107LINEN DISCHARGE& SORTING110EMPLOYEEROOM112LAUNDRYLOUNGE110AEMP RR ADA140LINEN CHUTE111ELEV 1113ELEV 2110BEMP RR114FITNESS116MEN'SRESTROOM115WOMEN'SRESTROOM119MEETINGSTORAGE120MEETING ROOM118GUEST STORAGE106STAIR 1117ELEVATOR LOBBY103POOL MEP100AVESTIBULE109AHOUSEKEEPINGOFFICE105ABOH DRYERext10ext7ext7ext7nnnnnnn nnnnnnnnnnnnnnnnnnooonC96H11-71OSnnnLDM1LDM1aLDM1bLDM1oLDM1LDM1ext4ext7LCM1ext5LCM1ext5LDM1ext7H11-15H11-15H11-15H11-15H11-15H11-15H11-15H11-15H11-15H11-15H11-15H11-15H11-15ext10LCM1L12-38H11-15H11-15H11-15H11-15H11-15H11-15H11-15H11-15H11-15H11-15H11-15H11-15H11-15H11-15H11-15ext10LCM1L1246LDM1477588891011LDM1R08
a
R08E
a
R08E
a
R08
a
R08
a
R08E
a
R08
a
R08
a
R08E
a
R08
a
W04H11-5bH11-7 H11-7
H11-7H11-7H11-7
H11-7 H11-7 H11-7
H11-7H11-73E-102TYPE32 MERCHANT STREET, SUITE 208HONOLULU, HI 96813808-352-5299OWNER:HOMEWOOD SUITES by HILTON
SPOKANE VALLEY, WA
13515 E. Carlisle Avenue
Spokane Valley, WA 99216FSC PROJECT NO. 21012PERMITDOCUMENTSMay 31, 2024GL8 MirabeauPoint, LLCTMK:PID: 45101.0401 10909 E. Pierce LaneSpokane, WA 99206(509) 919-0901Revision ScheduleNumber Description Date5915 S REGAL STREETSUITE 201SPOKANE, WA 99223PH: 509.473.9218Kelly@kwrllc.comwww.kwrllc.com5/30/2024 12:49:45 PMSTATE OF WASHINGTONREGISTERED PROFESSIONAL ENG
INEER48350 KELLY A
N
DREW WATERMAN05.31.24FIRST FLOORLIGHTING PLAN -AREA AE-201AGENERAL NOTESA. PROVIDE UN-SWITCHED HOT CONDUCTOR TO ALL EMERGENCY LUMINAIRESAND EXIT SIGNS. EMERGENCY LUNIMAIRES ARE INDICATED BY HATCHINGAND/OR WITH AN 'E' DESIGNATION ON THE END OF FIXTURE NAME.B. PROVIDE ALL HARDWARE AND ACCESSORIES REQUIRED TO MOUNTLUMINAIRE IN LOCATIONS SHOWN INCLUDING ALL MOUNTING BRACKETS,T-BAR HANGERS, CANOPIES, ETC.C. LIGHTING CONTROLS BASIS OF DESIGN IS A DIGITAL DISTRIBUTED,NETWORKABLE SYSTEM CONSISTING OF CONTROL/DIMMING MODULES ANDBOTH MANUAL AND AUTOMATIC INPUT DEVICES (OCCUPANCY SENSORS,DAYLIGHT SENSORS, AND MANUAL CONTROL STATIONS. EACH SPACE SHALLCONSIST OF A LOCAL LIGHTING CONTROL NETWORK, WITH ALL CONTROLDEVICES IN THE SPACE CONNECTED TOGETHER VIA CAT-5E NETWORK IN ADAISY CHAIN TOPOLOGY. EACH SPACE SHALL HAVE A NETWORK HOME RUNOF CAT-5E CABLE THAT TERMINATES ON A DEDICATED BRIDGE PORT ON THENEAREST NETWORK BRIDGE. INTERIOR AND EXTERIOR LIGHTING ZONESSHALL TERMINATE ON DEDICATED NETWORK BRIDGES OR BRIDGE HUBS.ACTUAL QUANTITY OF BRIDGES NOT SHOWN AND SHALL BE DETERMINED ONMANUFACTURER'S SHOP DRAWINGS.D. ALL OCCUPANCY SENSORS SHALL BE SET TO A DEFAULT TIME DELAY OF 15MINUTES. OCCUPANCY SENSORS IN RESTROOMS AND CORRIDORS SHALL BESET TO AUTO ON, AUTO OFF. ALL OTHER OCCUPANCY SENSORS SHALL BESET TO MANUAL ON, AUTO OFF UNLESS OTHERWISE NOTED.E. EXTERIOR LIGHTING CONTROL ZONES SEQUENCE OF OPERATION ASFOLLOWS:- ext3: FULL BRIGHTNESS FROM DUSK TO DAWN, FOR OCCUPANT SAFETY.- ext4: FULL BRIGHTNESS FROM DUSK TO DAWN, FOR OCCUPANT SAFETY- ext5: FULL BRIGHTNESS FROM DUSK TO 11PM, 30% BRIGHTNESS FROM 11PM TO 6AM, FULL BRIGHTNESS FROM 6AM TO DAWN.- ext6: FULL BRIGHTNESS FROM DUSK TO 11PM, 30% BRIGHTNESS FROM 11PM TO 6AM, FULL BRIGHTNESS FROM 6AM TO DAWN.- ext7: FULL BRIGHTNESS FROM DUSK TO DAWN, FOR OCCUPANT SAFETY.- ext8: FULL BRIGHTNESS FROM DUSK TO 11PM, 30% BRIGHTNESS FROM 11PM TO 6AM, FULL BRIGHTNESS FROM 6AM TO DAWN.- ext9: FULL BRIGHTNESS FROM DUSK TO 11PM, 30% BRIGHTNESS FROM 11PM TO 6AM, FULL BRIGHTNESS FROM 6AM TO DAWN.- ext10: FULL BRIGHTNESS FROM DUSK TO DAWN, FOR OCCUPANT SAFETY.COORDINATE SCHEDULING AND BRIGHTNESS LEVELS WITH OWNER PRIORTO PROJECT CLOSEOUT.FLAG NOTESMOUNT LIGHTING CONTROL MODULE TO JUNCTION BOX ABOVE ACCESSIBLE CEILING.CONNECT UN-SWITCHED CIRCUIT TO LINE SIDE OF MODULE AND EXTEND SWITCHEDCIRCUIT AND 0-10V DIMMING CIRCUIT TO LIGHTING ZONES INDICATED. IN AREASWITH INACCESSIBLE CEILINGS, LOCATE DEVICES IN NEAREST ADJACENT ACCESSIBLECEILING OR NON-PUBLIC UTILITY SPACE. DEVICES SHALL BE LOCATEDCONSISTENTLY FOR SIMILAR SPACES (I.E. ABOVE DOORS IN OFFICES).MOUNT BRIDGE DEVICE ABOVE ACCESSIBLE CEILING. BRIDGE TO RECEIVE HOMERUNS FROM LOCAL LIGHTING CONTROL NETWORK DAISY CHAINS IN ADJACENTAREAS. NOT ALL BRIDGES ARE SHOWN, PROVIDE BRIDGES AS REQUIRED TO ACCEPTA DEDICATED LOCAL NETWORK HOMERUN FROM EACH SPACE. REFER TOMANUFACTURER'S SHOP DRAWINGS FOR FINAL QUANTITIES.LIGHTING SYSTEM CONTROLLER. PROVIDE 120V POWER SUPPLY AND NETWORKBRIDGE TO ORIGINATE LIGHTING CONTROL NETWORK BUS. CONNECT TO ADDITIONALBRIDGES AS REQUIRED TO EXTEND LIGHTING CONTROL NETWORK THROUGHOUTTHE BUILDING AREA.LIGHTING CONTROLS IN THIS SPACE SHALL UTILIZE TIME-BASED AUTOMATICCONTROL BASED ON BUSINESS HOURS DEFINED BY THE OWNER DURING STARTUP.LIGHTING CONTROL MODULES AND DEVICES TO BE CONNECTED TO DIGITALLIGHTING CONTROL NETWORK TO OBTAIN TIME-CLOCK SIGNAL. CONTROL STATIONSIN THIS SPACE ARE INTENDED FOR DIMMING CONTROL AND 2-HOUR LOCALOVERRIDE OUTSIDE OF BUSINESS HOURS.OCCUPANCY SENSORS IN THIS SPACE SHALL FUNCTION AUTO-OFF, AUTO-ON FOROCCUPANT SAFETY.PROPOSED LOCATION FOR NLIGHT AIR ANTENNA AND POWER CONNECTIONADJACENT TO ANTENNA. PROVIDE NETWORK CONNECTION FROM GATEWAY TOANTENNA. PROVIDE ANTENNA POWER SUPPLY ADAPTER AS REQUIRED.OCCUPANT SENSORS IN THIS SPACE SHALL FUNCTION AUTO-OFF, AUTO-ON TO 50%.CONTROL / DIMMING MODULE(S) FOR EXTERIOR LIGHTING ZONE. LOCATION ISPRELIMINARY PROPOSED LOCATION. CONTRACTOR TO FIELD COORDINATEMOUNTING LOCATION FOR CIRCUITING TO EXTERIOR ZONE NOTED.POWER SUPPLY LOCATIONS SHOWN ARE DIAGRAMMATIC. FIELD COORDINATEMOUNTING IN ACCESSIBLE CEILING OR IN NEAREST CASEWORK.BREAK LINES SHOWN IN ACCENT / COVE LIGHT ARE DIAGRAMMATIC. MAXIMUMLENGTH ALLOWED ON SINGLE POWER SUPPLY IS 33 FEET. FIELD COORDINATE CUTLOCATIONS AND 24V POWER SUPPLY CONNECTION LOCATIONS.VESTIBULE TO BE CONTROLLED IN SAME ZONE AS ADJACENT INTERIOR SPACE.1SCALE:1/8" = 1'-0"FIRST FLOOR LIGHTING PLAN - AREA ASHEET E-201A
SHEET E-201B
SHEET E-201A
SHEET E-201B
234567891011
TTSC-20X18X8.62BOXML.1EKNPQ2JLW01W01W01W03W02W02W01W01C96E1R22R22R22R26R26R26b,dz1b,dz2b,dz1b,dz2Z01Z01Z01Z02Z03B20AB20AB20AB20AB20AB20AB25P04P04P04P02Z02Z02Z02B20AB20AB20AW02W02LDM1LDM1LDM1LDM1B21EW02W02B06EB06SZ01SZ01P05P05P05SZ03R22R22R24R24R24R24
R24 R24W03EOS33B20AX01666X01X01X01X03X01X01X03X03X01C96EB20AB20AB20AB20Aa2C48
7W48Eext4ext4ext5ext5ext5ext5ext5ext5ext8ext8ext8ext9ext9ext9W48ES21S21S21S21S21S21S21S21S21S21S21S21S21S21S21S21ext10ext10ext10ext10ext10ext10ext10ext10ext10ext10ext10ext10ext10ext10ext10ext10B06EB06B06EB06EB06EB06B06B06EB06EB06B06EB06R21 R21ER21R21R21ER21ER21R21R21E31LDM1SZ02ext8SZ02ext8B20AB20AZ01Z03B20AB20AB25B25B20AB20AB20AB20AB20AB20AB20AB20AB20AB20AB20AB20AB20AB20AB20ALDM11TYP Z02Z028L12EL12L12EL06L06L06L06L06AL06Aext3ext3ext3ext3ext3ext3ext3ext3ext3L07L07EL07EL07EL07EZ01D04D04D04D04W06 (TYP)W06 (TYP)W06 (TYP)W06 (TYP)W06 (TYP)W06 (TYP)L12EL12EZ05P06P06Z04Z04Z04PS1PS1PS1PS1PS1PS1PS1PS1PS1PS1PS1PS1PS1PS1PS1PS1PS1Z02PS1PS1PS2PS2PS2LDM1LDMVLDMVH12H12-1H12-1H12-1H12-1H12-1H12-1H12-1H12-1H12-1H12-1H12-1H12-1H12-1H12-1H12-1H12-1H12-1H12-1H12-1H12-1H12-1H12-1H12-1H12-1 H12-1H12-1H12-1H12-1H12-1 H12-1H12-1
H12-1 H12-1H12-1H12-1H12-1H12-1H12-1H12-1H12-1H12-1H12-1H12-1H12-1L14AL14BL14A-32L14A-32L14A-32L14A-32L14A-32W01L14A-32PS1PS1H11-7H11-7H11-7H12-1H12-1H12-1Z04S21S21S21ext10S21ext10PS1 H12-3H12-7H12-7H12-3H12-3H12-3H12-3H12-3H12-3H12-3H12-3H12-3H12-3H12-3H12-7H12-7H12-7H12-7H12-3H12-3H12-3H12-3H12-3H12-3H12-3H12-7H12-3H12-3H12-3H12-3H12-3H12-7H12-7H12-3H12-3H12-3H12-3H12-3H12-3H12-3H12-3H12-3H12-3H12-7H12-7H12-3H12-3H12-3H12-3H12-3H12-3H12-3H12-3H12-3H12-3H12-3H12-3H12-7H12-7H12-7H12-7H12-7H12-7L14A-32L14A-32L14A-32L14A-32H12-5H12-5H12-5H12-5H12-5H12-5H12-5H12-5H12-5L14A-32 L14A-32L14A-32 L14A-32H12-7H12-3H12-5H12-5L14A-32L14A-32H12-7121LOBBY122VESTIBULE123FOOD PREP128ELECTRICAL124OPEN OFFICE126SALES OFFICE125GM OFFICE127OWNER'S OFFICE132STAIR 2139GUEST CORRIDOR139BELECTRICAL130KING STUDIO134EFFICIENCY136DOUBLE QUEEN138KING STUDIOADA-M-T129EFFICIENCY131EFFICIENCY133EFFICIENCY135DOUBLE QUEEN137KING STUDIO141COURTYARDSTORAGE139AVESTIBULE121APUBLIC CORRIDORZ01H12-7ext10ext10ext3ext3ext3ext3LCM1ext3LDM1ext3ext6ext6ext6ext6LCM1LDM1ext6ext6ext7ext9ext9L16ext9aaaabcccccccdf-dz8 f-dz8f-dz8f-dz8ggghhhhhii-dz8i-dz7i-dz7i-dz7i-dz1i-dz1i-dz1 i-dz1i-dz1i-dz2i-dz2i-dz2i-dz2i-dz2iiii-dz4i-dz3i-dz4i-dz3i-dz6i-dz5ii-dz5i-dz5i-dz5i-dz6i-dz6i-dz6i-dz6jjkkkkkim-dz4m-dz3m-dz4nnnnnncacaacaacaabbbk j dLDM1LDM1bLDM1caLDM1dnnkext6LDM1kLDM1i-dz3LDM1i-dz4LDM1m-dz3LDM1m-dz4LDM1i-dz1LDM1i-dz2LDM1iLDM1i-dz7LDM1i-dz8LDM1i-dz5LDM1i-dz6LDM1hLDM1f-dz8LDMVgLDM1jLDMVppLDM1ext8ext8ext8ext8LDM1ext8LDMVext9LDM1ext9ext5LDM1ext4ext7LCM1LPAT-7LPAT-7LPAT-7LPAT-7LPAT-7H12-5H12-5H12-5H12-5H12-5H12-5H12-9H12-9H12-9H12-9H12-9H12-9H12-9H12-9H12-9L12-38H11-15H11-15H12-9H12-9H11-15H11-15ext10LCM1H12-9H12-9H12-9H12-9H12-9H12-9H12-9H12-9H12-9H12-9H12-9H12-9H12-9H11-15BRDG23444445TYP66667789TYP TYP9 10101011LDM1DLdz1dz2DLdz3dz4DLdz5dz6DLdz7dz8123E-102TYPFGH8.19781043156E1132 MERCHANT STREET, SUITE 208HONOLULU, HI 96813808-352-5299OWNER:HOMEWOOD SUITES by HILTON
SPOKANE VALLEY, WA
13515 E. Carlisle Avenue
Spokane Valley, WA 99216FSC PROJECT NO. 21012PERMITDOCUMENTSMay 31, 2024GL8 MirabeauPoint, LLCTMK:PID: 45101.0401 10909 E. Pierce LaneSpokane, WA 99206(509) 919-0901Revision ScheduleNumber Description Date5915 S REGAL STREETSUITE 201SPOKANE, WA 99223PH: 509.473.9218Kelly@kwrllc.comwww.kwrllc.com5/30/2024 12:50:05 PMSTATE OF WASHINGTONREGISTERED PROFESSIONAL ENG
INEER48350 KELLY A
N
DREW WATERMAN05.31.24FIRST FLOORLIGHTING PLAN -AREA BE-201BSCALE:1/8" = 1'-0"FIRST FLOOR LIGHTING PLAN - AREA BSHEET E-201ASHEET E-201BSHEET E-201ASHEET E-201B
FLAG NOTESMOUNT LIGHTING CONTROL MODULE TO JUNCTION BOX ABOVE ACCESSIBLE CEILING.CONNECT UN-SWITCHED CIRCUIT TO LINE SIDE OF MODULE AND EXTEND SWITCHEDCIRCUIT AND 0-10V DIMMING CIRCUIT TO LIGHTING ZONES INDICATED. IN AREASWITH INACCESSIBLE CEILINGS, LOCATE DEVICES IN NEAREST ADJACENT ACCESSIBLECEILING OR NON-PUBLIC UTILITY SPACE. DEVICES SHALL BE LOCATEDCONSISTENTLY FOR SIMILAR SPACES (I.E. ABOVE DOORS IN OFFICES).MOUNT BRIDGE DEVICE ABOVE ACCESSIBLE CEILING. BRIDGE TO RECEIVE HOMERUNS FROM LOCAL LIGHTING CONTROL NETWORK DAISY CHAINS IN ADJACENTAREAS. NOT ALL BRIDGES ARE SHOWN, PROVIDE BRIDGES AS REQUIRED TO ACCEPTA DEDICATED LOCAL NETWORK HOMERUN FROM EACH SPACE. REFER TOMANUFACTURER'S SHOP DRAWINGS FOR FINAL QUANTITIES.LIGHTING CONTROLS IN THIS SPACE SHALL UTILIZE TIME-BASED AUTOMATICCONTROL BASED ON BUSINESS HOURS DEFINED BY THE OWNER DURING STARTUP.LIGHTING CONTROL MODULES AND DEVICES TO BE CONNECTED TO DIGITALLIGHTING CONTROL NETWORK TO OBTAIN TIME-CLOCK SIGNAL. CONTROL STATIONSIN THIS SPACE ARE INTENDED FOR DIMMING CONTROL AND 2-HOUR LOCALOVERRIDE OUTSIDE OF BUSINESS HOURS.CONTROL / DIMMING MODULE(S) FOR EXTERIOR LIGHTING ZONE. LOCATION ISPRELIMINARY PROPOSED LOCATION. CONTRACTOR TO FIELD COORDINATEMOUNTING LOCATION FOR CIRCUITING TO EXTERIOR ZONE NOTED.POWER SUPPLY LOCATIONS SHOWN ARE DIAGRAMMATIC. FIELD COORDINATEMOUNTING IN ACCESSIBLE CEILING OR IN NEAREST CASEWORK.BREAK LINES SHOWN IN ACCENT / COVE LIGHT ARE DIAGRAMMATIC. MAXIMUMLENGTH ALLOWED ON SINGLE POWER SUPPLY IS 33 FEET. FIELD COORDINATE CUTLOCATIONS AND 24V POWER SUPPLY CONNECTION LOCATIONS.VESTIBULE TO BE CONTROLLED IN SAME ZONE AS ADJACENT INTERIOR SPACE.REFER TO ARCHITECTURAL CASEWORK, MILLWORK, COVE, AND CEILING DETAILS INTHIS SPACE FOR MOUNTING OF ALL ACCENT FIXTURES. SEE ARCHITECTURAL PLANSFOR EXACT DIMENSIONS, AND PROVIDE LENGTHS AS SHOWN.FIELD COORDINATE ROUTING OF 12V CONDUCTORS FROM INTERIOR POWER SUPPLY'PS2' TO COLUMN MOUNTED LUMINAIRE. LUMINAIRE MOUNTED IN RECESSED NOOKOF COLUMN.FIELD COORDINATE ALL POWER SUPPLY AND CONTROL MODULE DEVICES INEXTERIOR CASEWORK FOR PATIO LIGHTING ZONES. FIELD COORDINATE WITHCASEWORK, TRELLIS, AND FIREPIT MANUFACTURERS FOR CONCEALING BRANCHCIRCUITS WHERE POSSIBLE.LINEAR FIXTURE SHALL REPLACE SINGLE TRELLIS BEAM IN THIS APPROXIMATELOCATION. COORDINATE WITH TRELLIS MANUFACTURER FOR ROUGH-IN ANDINSTALLATION.GRAPHICAL CONTROL STATION FOR LOBBY AND CONNECTING CORRIDOR LIGHTINGCONTROL ZONES 'a' THROUGH 'o'. CONTROL STATION SHALL BE PASSWORDPROTECTED TO PREVENT USE BY UNAUTHORIZED PERSONNEL. PROVIDE SCENEPROGRAMMING FOR ASSOCIATED ZONES BASED UPON OWNER NEEDS, PRIOR TOPROJECT CLOSEOUT.123456789101112GENERAL NOTESA. PROVIDE UN-SWITCHED HOT CONDUCTOR TO ALL EMERGENCY LUMINAIRESAND EXIT SIGNS. EMERGENCY LUNIMAIRES ARE INDICATED BY HATCHINGAND/OR WITH AN 'E' DESIGNATION ON THE END OF FIXTURE NAME.B. PROVIDE ALL HARDWARE AND ACCESSORIES REQUIRED TO MOUNTLUMINAIRE IN LOCATIONS SHOWN INCLUDING ALL MOUNTING BRACKETS,T-BAR HANGERS, CANOPIES, ETC.C. LIGHTING CONTROLS BASIS OF DESIGN IS A DIGITAL DISTRIBUTED,NETWORKABLE SYSTEM CONSISTING OF CONTROL/DIMMING MODULES ANDBOTH MANUAL AND AUTOMATIC INPUT DEVICES (OCCUPANCY SENSORS,DAYLIGHT SENSORS, AND MANUAL CONTROL STATIONS. EACH SPACE SHALLCONSIST OF A LOCAL LIGHTING CONTROL NETWORK, WITH ALL CONTROLDEVICES IN THE SPACE CONNECTED TOGETHER VIA CAT-5E NETWORK IN ADAISY CHAIN TOPOLOGY. EACH SPACE SHALL HAVE A NETWORK HOME RUNOF CAT-5E CABLE THAT TERMINATES ON A DEDICATED BRIDGE PORT ON THENEAREST NETWORK BRIDGE. INTERIOR AND EXTERIOR LIGHTING ZONESSHALL TERMINATE ON DEDICATED NETWORK BRIDGES OR BRIDGE HUBS.ACTUAL QUANTITY OF BRIDGES NOT SHOWN AND SHALL BE DETERMINED ONMANUFACTURER'S SHOP DRAWINGS.D. ALL OCCUPANCY SENSORS SHALL BE SET TO A DEFAULT TIME DELAY OF 15MINUTES. OCCUPANCY SENSORS IN RESTROOMS AND CORRIDORS SHALL BESET TO AUTO ON, AUTO OFF. ALL OTHER OCCUPANCY SENSORS SHALL BESET TO MANUAL ON, AUTO OFF UNLESS OTHERWISE NOTED.E. EXTERIOR LIGHTING CONTROL ZONES SEQUENCE OF OPERATION ASFOLLOWS:- ext3: FULL BRIGHTNESS FROM DUSK TO DAWN, FOR OCCUPANT SAFETY.- ext4: FULL BRIGHTNESS FROM DUSK TO DAWN, FOR OCCUPANT SAFETY- ext5: FULL BRIGHTNESS FROM DUSK TO 11PM, 30% BRIGHTNESS FROM 11PM TO 6AM, FULL BRIGHTNESS FROM 6AM TO DAWN.- ext6: FULL BRIGHTNESS FROM DUSK TO 11PM, 30% BRIGHTNESS FROM 11PM TO 6AM, FULL BRIGHTNESS FROM 6AM TO DAWN.- ext7: FULL BRIGHTNESS FROM DUSK TO DAWN, FOR OCCUPANT SAFETY.- ext8: FULL BRIGHTNESS FROM DUSK TO 11PM, 30% BRIGHTNESS FROM 11PM TO 6AM, FULL BRIGHTNESS FROM 6AM TO DAWN.- ext9: FULL BRIGHTNESS FROM DUSK TO 11PM, 30% BRIGHTNESS FROM 11PM TO 6AM, FULL BRIGHTNESS FROM 6AM TO DAWN.- ext10: FULL BRIGHTNESS FROM DUSK TO DAWN, FOR OCCUPANT SAFETY.COORDINATE SCHEDULING AND BRIGHTNESS LEVELS WITH OWNER PRIORTO PROJECT CLOSEOUT.
W/D
W/D
DNUP53.16.12.1DC.1ECCBB8.1941.1A78610W01W01B22AEB22B22AEB26B26B26B22EB06E1C48EC48C48EC48EC48C48C48EW01W01W01W01W01W012X03C48X01X03X01LDM1OSOS1LDM1C96EC96C96EOS1TYP
X02B06EB06B06EB06B06EB06B06B06EB06B06EB06B06EB06B06EB06213W01W01W48EH11-13H11-13H11-13H11-13H11-13H11-13H11-13 H11-13H11-13H11-13H11-13H11-13H11-13H11-13H11-13H11-13H11-13H11-13H11-13H11-13H11-13H11-13H11-13H11-13H11-13H11-13H11-13H11-9H11-13H11-13H11-13H11-13H11-13H11-13H11-13H11-13L21-14L21-14L21-14L21-14L21-14L21-14L21-14L21-14L21-14L21-14H11-13H11-13H11-13H11-13111ELEV 1113ELEV 2217ELEVATOR LOBBY209LINENS &HOUSEKEEPING140LINEN CHUTE207ENGINEERINGOFFICE & STORAGE207APBX/MDF209APANELS206STAIR 1208EFFICIENCY205EFFICIENCY203EFFICIENCYENLARGED201KING 1-BEDROOMENLARGED202KING1-BEDROOM204KING STUDIO210DOUBLE QUEEN212DOUBLE QUEENENLARGED214KING STUDIO216KING STUDIO218KING STUDIO200CONNECTINGCORRIDOR209BIDF209CDAC201ABALCONY202ABALCONYLDM1LDMVL21215GUESTCORRIDOR242C48E
C48
H11-13
H11-13 W48EH11-7E31232 MERCHANT STREET, SUITE 208HONOLULU, HI 96813808-352-5299OWNER:HOMEWOOD SUITES by HILTON
SPOKANE VALLEY, WA
13515 E. Carlisle Avenue
Spokane Valley, WA 99216FSC PROJECT NO. 21012PERMITDOCUMENTSMay 31, 2024GL8 MirabeauPoint, LLCTMK:PID: 45101.0401 10909 E. Pierce LaneSpokane, WA 99206(509) 919-0901Revision ScheduleNumber Description Date5915 S REGAL STREETSUITE 201SPOKANE, WA 99223PH: 509.473.9218Kelly@kwrllc.comwww.kwrllc.com5/30/2024 12:50:14 PMSTATE OF WASHINGTONREGISTERED PROFESSIONAL ENG
INEER48350 KELLY A
N
DREW WATERMAN05.31.24SECOND FLOORLIGHTING PLAN -AREA AE-202ASCALE:1/8" = 1'-0"SECOND FLOOR LIGHTING PLAN - AREA ASHEET E-202A
SHEET E-202B
SHEET E-202A
SHEET E-202B
GENERAL NOTESA. PROVIDE UN-SWITCHED HOT CONDUCTOR TO ALL EMERGENCY LUMINAIRESAND EXIT SIGNS. EMERGENCY LUNIMAIRES ARE INDICATED BY HATCHINGAND/OR WITH AN 'E' DESIGNATION ON THE END OF FIXTURE NAME.B. PROVIDE ALL HARDWARE AND ACCESSORIES REQUIRED TO MOUNTLUMINAIRE IN LOCATIONS SHOWN INCLUDING ALL MOUNTING BRACKETS,T-BAR HANGERS, CANOPIES, ETC.C. LIGHTING CONTROLS BASIS OF DESIGN IS A DIGITAL DISTRIBUTED,NETWORKABLE SYSTEM CONSISTING OF CONTROL/DIMMING MODULES ANDBOTH MANUAL AND AUTOMATIC INPUT DEVICES (OCCUPANCY SENSORS,DAYLIGHT SENSORS, AND MANUAL CONTROL STATIONS. EACH SPACE SHALLCONSIST OF A LOCAL LIGHTING CONTROL NETWORK, WITH ALL CONTROLDEVICES IN THE SPACE CONNECTED TOGETHER VIA CAT-5E NETWORK IN ADAISY CHAIN TOPOLOGY. EACH SPACE SHALL HAVE A NETWORK HOME RUNOF CAT-5E CABLE THAT TERMINATES ON A DEDICATED BRIDGE PORT ON THENEAREST NETWORK BRIDGE. INTERIOR AND EXTERIOR LIGHTING ZONESSHALL TERMINATE ON DEDICATED NETWORK BRIDGES OR BRIDGE HUBS.ACTUAL QUANTITY OF BRIDGES NOT SHOWN AND SHALL BE DETERMINED ONMANUFACTURER'S SHOP DRAWINGS.D. ALL OCCUPANCY SENSORS SHALL BE SET TO A DEFAULT TIME DELAY OF 15MINUTES. OCCUPANCY SENSORS IN RESTROOMS AND CORRIDORS SHALL BESET TO AUTO ON, AUTO OFF. ALL OTHER OCCUPANCY SENSORS SHALL BESET TO MANUAL ON, AUTO OFF UNLESS OTHERWISE NOTED.FLAG NOTESMOUNT LIGHTING CONTROL MODULE TO JUNCTION BOX ABOVE ACCESSIBLE CEILING.CONNECT UN-SWITCHED CIRCUIT TO LINE SIDE OF MODULE AND EXTEND SWITCHEDCIRCUIT AND 0-10V DIMMING CIRCUIT TO LIGHTING ZONES INDICATED. IN AREASWITH INACCESSIBLE CEILINGS, LOCATE DEVICES IN NEAREST ADJACENT ACCESSIBLECEILING OR NON-PUBLIC UTILITY SPACE. DEVICES SHALL BE LOCATEDCONSISTENTLY FOR SIMILAR SPACES (I.E. ABOVE DOORS IN OFFICES).LIGHTING CONTROLS IN THIS SPACE SHALL UTILIZE TIME-BASED AUTOMATICCONTROL BASED ON BUSINESS HOURS DEFINED BY THE OWNER DURING STARTUP.LIGHTING CONTROL MODULES AND DEVICES TO BE CONNECTED TO DIGITALLIGHTING CONTROL NETWORK TO OBTAIN TIME-CLOCK SIGNAL.MANUAL OVERRIDE / DIMMING CONTROL STATION FOR CORRIDOR AND ELEVATORLOBBY LIGHTING THROUGHOUT THIS FLOOR.MANUAL OVERRIDE FOR STAIRWELL LOCATED ON FIRST FLOOR.1234
DNUPFGML.1EKNPQHJLW01X03X01X011X02B06B06B06EB06EB06EB06B06EB06B06EB06B06EB06B06EB06B06EB06W01W01W01W01W01W01W01W01W01W48EH11-13H11-13H11-13H11-13H11-13H12-1H11-13H11-13H11-13H11-13H11-13H11-13H11-13H11-13H11-13H11-13H11-13H11-13H11-13H11-13H11-13L21-14L21-14L21-14L21-14L21-14L21-14L21-14L21-14L21-14L21-14220KING STUDIO226KING STUDIO230KING STUDIO238KING STUDIOADA-M-T219KING STUDIO221KING STUDIO223KING STUDIO225KING STUDIO227EFFICIENCY229EFFICIENCY231EFFICIENCY233EFFICIENCY237KING STUDIO235DOUBLE QUEEN232STAIR 2228EFFICIENCY234EFFICIENCY236DOUBLE QUEEN224DOUBLE QUEEN222DOUBLE QUEEN215AELECTRICAL215GUESTCORRIDOR235ABALCONY237ABALCONY225ABALCONY223ABALCONY221ABALCONY219ABALCONY231W48EH12-156.18.1978610E1132 MERCHANT STREET, SUITE 208HONOLULU, HI 96813808-352-5299OWNER:HOMEWOOD SUITES by HILTON
SPOKANE VALLEY, WA
13515 E. Carlisle Avenue
Spokane Valley, WA 99216FSC PROJECT NO. 21012PERMITDOCUMENTSMay 31, 2024GL8 MirabeauPoint, LLCTMK:PID: 45101.0401 10909 E. Pierce LaneSpokane, WA 99206(509) 919-0901Revision ScheduleNumber Description Date5915 S REGAL STREETSUITE 201SPOKANE, WA 99223PH: 509.473.9218Kelly@kwrllc.comwww.kwrllc.com5/30/2024 12:50:24 PMSTATE OF WASHINGTONREGISTERED PROFESSIONAL ENG
INEER48350 KELLY A
N
DREW WATERMAN05.31.24SECOND FLOORLIGHTING PLAN -AREA BE-202BSCALE:1/8" = 1'-0"SECOND FLOOR LIGHTING PLAN - AREA BSHEET E-202ASHEET E-202BSHEET E-202ASHEET E-202B
GENERAL NOTESA. PROVIDE UN-SWITCHED HOT CONDUCTOR TO ALL EMERGENCY LUMINAIRESAND EXIT SIGNS. EMERGENCY LUNIMAIRES ARE INDICATED BY HATCHINGAND/OR WITH AN 'E' DESIGNATION ON THE END OF FIXTURE NAME.B. PROVIDE ALL HARDWARE AND ACCESSORIES REQUIRED TO MOUNTLUMINAIRE IN LOCATIONS SHOWN INCLUDING ALL MOUNTING BRACKETS,T-BAR HANGERS, CANOPIES, ETC.C. LIGHTING CONTROLS BASIS OF DESIGN IS A DIGITAL DISTRIBUTED,NETWORKABLE SYSTEM CONSISTING OF CONTROL/DIMMING MODULES ANDBOTH MANUAL AND AUTOMATIC INPUT DEVICES (OCCUPANCY SENSORS,DAYLIGHT SENSORS, AND MANUAL CONTROL STATIONS. EACH SPACE SHALLCONSIST OF A LOCAL LIGHTING CONTROL NETWORK, WITH ALL CONTROLDEVICES IN THE SPACE CONNECTED TOGETHER VIA CAT-5E NETWORK IN ADAISY CHAIN TOPOLOGY. EACH SPACE SHALL HAVE A NETWORK HOME RUNOF CAT-5E CABLE THAT TERMINATES ON A DEDICATED BRIDGE PORT ON THENEAREST NETWORK BRIDGE. INTERIOR AND EXTERIOR LIGHTING ZONESSHALL TERMINATE ON DEDICATED NETWORK BRIDGES OR BRIDGE HUBS.ACTUAL QUANTITY OF BRIDGES NOT SHOWN AND SHALL BE DETERMINED ONMANUFACTURER'S SHOP DRAWINGS.D. ALL OCCUPANCY SENSORS SHALL BE SET TO A DEFAULT TIME DELAY OF 15MINUTES. OCCUPANCY SENSORS IN RESTROOMS AND CORRIDORS SHALL BESET TO AUTO ON, AUTO OFF. ALL OTHER OCCUPANCY SENSORS SHALL BESET TO MANUAL ON, AUTO OFF UNLESS OTHERWISE NOTED.FLAG NOTESLIGHTING CONTROLS IN THIS SPACE SHALL UTILIZE TIME-BASED AUTOMATICCONTROL BASED ON BUSINESS HOURS DEFINED BY THE OWNER DURING STARTUP.LIGHTING CONTROL MODULES AND DEVICES TO BE CONNECTED TO DIGITALLIGHTING CONTROL NETWORK TO OBTAIN TIME-CLOCK SIGNAL.MANUAL OVERRIDE FOR THIS SPACE LOCATED IN HOUSEKEEPING ROOM ON THISFLOOR.MANUAL OVERRIDE FOR STAIRWELL LOCATED ON FIRST FLOOR.123
W/D
DNUPW D
Microwave53.16.12.1DC.1ECCBB8.1941.1A78610W48EW01W01B22AEB22B22AEB26B26B26B22EB06E1W01W01W01W01W01W012X03X01X03X01LDM1OSOS2X02B06EB06B06EB06B06EB06B06B06EB06B06EB06B06EB06B06EB062W01W01H41-5H41-5H41-5H41-5H41-5H41-5H41-5H41-5H41-5H41-5H41-5H41-5H41-5H41-5H41-5H41-5H41-5H41-5H41-5H41-5H41-5H41-5H11-9H41-5H41-5H41-5H41-5H41-5H41-5L31-8L31-8L31-8L31-8L31-8L31-8L31-8L31-8L31-8L31-8111ELEV. 1113ELEV. 2317ELEVATOR LOBBY309LINENS &HOUSEKEEPING140LINEN CHUTE307EFFICIENCY309BIDF309APANELS306STAIR 1308EFFICIENCY305EFFICIENCY303EFFICIENCYENLARGED301KING 1-BEDROOMADA-M-T302KING1-BEDROOM304KING STUDIO310DOUBLE QUEEN312DOUBLE QUEENENLARGED314KING STUDIO316KING STUDIO318KING STUDIO300CONNECTINGCORRIDOR309CDAC301ABALCONY302ABALCONY13LDM1LDMV1TYP L3142315GUEST CORRIDORC48EC48C48EC48EC48C48C48EC48H41-5H41-5H41-5H41-5H41-5H41-5H41-5H41-5W48EH11-9E31232 MERCHANT STREET, SUITE 208HONOLULU, HI 96813808-352-5299OWNER:HOMEWOOD SUITES by HILTON
SPOKANE VALLEY, WA
13515 E. Carlisle Avenue
Spokane Valley, WA 99216FSC PROJECT NO. 21012PERMITDOCUMENTSMay 31, 2024GL8 MirabeauPoint, LLCTMK:PID: 45101.0401 10909 E. Pierce LaneSpokane, WA 99206(509) 919-0901Revision ScheduleNumber Description Date5915 S REGAL STREETSUITE 201SPOKANE, WA 99223PH: 509.473.9218Kelly@kwrllc.comwww.kwrllc.com5/30/2024 12:50:34 PMSTATE OF WASHINGTONREGISTERED PROFESSIONAL ENG
INEER48350 KELLY A
N
DREW WATERMAN05.31.24THIRD FLOORLIGHTING PLAN -AREA AE-203ASCALE:1/8" = 1'-0"THIRD FLOOR LIGHTING PLAN - AREA ASHEET E-203A
SHEET E-203B
SHEET E-203A
SHEET E-203B
GENERAL NOTESA. PROVIDE UN-SWITCHED HOT CONDUCTOR TO ALL EMERGENCY LUMINAIRESAND EXIT SIGNS. EMERGENCY LUNIMAIRES ARE INDICATED BY HATCHINGAND/OR WITH AN 'E' DESIGNATION ON THE END OF FIXTURE NAME.B. PROVIDE ALL HARDWARE AND ACCESSORIES REQUIRED TO MOUNTLUMINAIRE IN LOCATIONS SHOWN INCLUDING ALL MOUNTING BRACKETS,T-BAR HANGERS, CANOPIES, ETC.C. LIGHTING CONTROLS BASIS OF DESIGN IS A DIGITAL DISTRIBUTED,NETWORKABLE SYSTEM CONSISTING OF CONTROL/DIMMING MODULES ANDBOTH MANUAL AND AUTOMATIC INPUT DEVICES (OCCUPANCY SENSORS,DAYLIGHT SENSORS, AND MANUAL CONTROL STATIONS. EACH SPACE SHALLCONSIST OF A LOCAL LIGHTING CONTROL NETWORK, WITH ALL CONTROLDEVICES IN THE SPACE CONNECTED TOGETHER VIA CAT-5E NETWORK IN ADAISY CHAIN TOPOLOGY. EACH SPACE SHALL HAVE A NETWORK HOME RUNOF CAT-5E CABLE THAT TERMINATES ON A DEDICATED BRIDGE PORT ON THENEAREST NETWORK BRIDGE. INTERIOR AND EXTERIOR LIGHTING ZONESSHALL TERMINATE ON DEDICATED NETWORK BRIDGES OR BRIDGE HUBS.ACTUAL QUANTITY OF BRIDGES NOT SHOWN AND SHALL BE DETERMINED ONMANUFACTURER'S SHOP DRAWINGS.D. ALL OCCUPANCY SENSORS SHALL BE SET TO A DEFAULT TIME DELAY OF 15MINUTES. OCCUPANCY SENSORS IN RESTROOMS AND CORRIDORS SHALL BESET TO AUTO ON, AUTO OFF. ALL OTHER OCCUPANCY SENSORS SHALL BESET TO MANUAL ON, AUTO OFF UNLESS OTHERWISE NOTED.FLAG NOTESMOUNT LIGHTING CONTROL MODULE TO JUNCTION BOX ABOVE ACCESSIBLE CEILING.CONNECT UN-SWITCHED CIRCUIT TO LINE SIDE OF MODULE AND EXTEND SWITCHEDCIRCUIT AND 0-10V DIMMING CIRCUIT TO LIGHTING ZONES INDICATED. IN AREASWITH INACCESSIBLE CEILINGS, LOCATE DEVICES IN NEAREST ADJACENT ACCESSIBLECEILING OR NON-PUBLIC UTILITY SPACE. DEVICES SHALL BE LOCATEDCONSISTENTLY FOR SIMILAR SPACES (I.E. ABOVE DOORS IN OFFICES).LIGHTING CONTROLS IN THIS SPACE SHALL UTILIZE TIME-BASED AUTOMATICCONTROL BASED ON BUSINESS HOURS DEFINED BY THE OWNER DURING STARTUP.LIGHTING CONTROL MODULES AND DEVICES TO BE CONNECTED TO DIGITALLIGHTING CONTROL NETWORK TO OBTAIN TIME-CLOCK SIGNAL.MANUAL OVERRIDE / DIMMING CONTROL STATION FOR CORRIDOR AND ELEVATORLOBBY LIGHTING THROUGHOUT THIS FLOOR.MANUAL OVERRIDE FOR STAIRWELL LOCATED ON FIRST FLOOR.1234
DNUPLW48EW011X03X01X011X02B06B06B06EB06EB06EB06B06EB06B06EB06B06EB06B06EB06B06EB06W01W01W01W01W01W01W01W01W01H41-5H41-5H41-5H41-5H12-1H41-5H41-5H41-5H41-5H41-5H41-5H41-5H41-5H41-5H41-5H41-5H41-5H41-5H41-5H41-5H41-5L31-8L31-8L31-8L31-8L31-8L31-8L31-8L31-8L31-8L31-8315AELECTRICAL320KING STUDIO326KING STUDIO330KING STUDIO338KING STUDIOENLARGED319KING STUDIO321KING STUDIO323KING STUDIO325KING STUDIO327EFFICIENCY329EFFICIENCY331EFFICIENCY333EFFICIENCY337KING STUDIO335DOUBLE QUEEN332STAIR 2328EFFICIENCY334EFFICIENCY336DOUBLE QUEEN324DOUBLE QUEEN322DOUBLE QUEEN315GUEST CORRIDOR335ABALCONY337ABALCONY325ABALCONY323ABALCONY321ABALCONY319ABALCONY23W48EH12-156.18.1978610FGHML.1KNPQJE32 MERCHANT STREET, SUITE 208HONOLULU, HI 96813808-352-5299OWNER:HOMEWOOD SUITES by HILTON
SPOKANE VALLEY, WA
13515 E. Carlisle Avenue
Spokane Valley, WA 99216FSC PROJECT NO. 21012PERMITDOCUMENTSMay 31, 2024GL8 MirabeauPoint, LLCTMK:PID: 45101.0401 10909 E. Pierce LaneSpokane, WA 99206(509) 919-0901Revision ScheduleNumber Description Date5915 S REGAL STREETSUITE 201SPOKANE, WA 99223PH: 509.473.9218Kelly@kwrllc.comwww.kwrllc.com5/30/2024 12:50:45 PMSTATE OF WASHINGTONREGISTERED PROFESSIONAL ENG
INEER48350 KELLY A
N
DREW WATERMAN05.31.24THIRD FLOORLIGHTING PLAN -AREA BE-203BSCALE:1/8" = 1'-0"THIRD FLOOR LIGHTING PLAN - AREA BSHEET E-203ASHEET E-203BSHEET E-203ASHEET E-203B
GENERAL NOTESA. PROVIDE UN-SWITCHED HOT CONDUCTOR TO ALL EMERGENCY LUMINAIRESAND EXIT SIGNS. EMERGENCY LUNIMAIRES ARE INDICATED BY HATCHINGAND/OR WITH AN 'E' DESIGNATION ON THE END OF FIXTURE NAME.B. PROVIDE ALL HARDWARE AND ACCESSORIES REQUIRED TO MOUNTLUMINAIRE IN LOCATIONS SHOWN INCLUDING ALL MOUNTING BRACKETS,T-BAR HANGERS, CANOPIES, ETC.C. LIGHTING CONTROLS BASIS OF DESIGN IS A DIGITAL DISTRIBUTED,NETWORKABLE SYSTEM CONSISTING OF CONTROL/DIMMING MODULES ANDBOTH MANUAL AND AUTOMATIC INPUT DEVICES (OCCUPANCY SENSORS,DAYLIGHT SENSORS, AND MANUAL CONTROL STATIONS. EACH SPACE SHALLCONSIST OF A LOCAL LIGHTING CONTROL NETWORK, WITH ALL CONTROLDEVICES IN THE SPACE CONNECTED TOGETHER VIA CAT-5E NETWORK IN ADAISY CHAIN TOPOLOGY. EACH SPACE SHALL HAVE A NETWORK HOME RUNOF CAT-5E CABLE THAT TERMINATES ON A DEDICATED BRIDGE PORT ON THENEAREST NETWORK BRIDGE. INTERIOR AND EXTERIOR LIGHTING ZONESSHALL TERMINATE ON DEDICATED NETWORK BRIDGES OR BRIDGE HUBS.ACTUAL QUANTITY OF BRIDGES NOT SHOWN AND SHALL BE DETERMINED ONMANUFACTURER'S SHOP DRAWINGS.D. ALL OCCUPANCY SENSORS SHALL BE SET TO A DEFAULT TIME DELAY OF 15MINUTES. OCCUPANCY SENSORS IN RESTROOMS AND CORRIDORS SHALL BESET TO AUTO ON, AUTO OFF. ALL OTHER OCCUPANCY SENSORS SHALL BESET TO MANUAL ON, AUTO OFF UNLESS OTHERWISE NOTED.FLAG NOTESLIGHTING CONTROLS IN THIS SPACE SHALL UTILIZE TIME-BASED AUTOMATICCONTROL BASED ON BUSINESS HOURS DEFINED BY THE OWNER DURING STARTUP.LIGHTING CONTROL MODULES AND DEVICES TO BE CONNECTED TO DIGITALLIGHTING CONTROL NETWORK TO OBTAIN TIME-CLOCK SIGNAL.MANUAL OVERRIDE FOR THIS SPACE LOCATED IN HOUSEKEEPING ROOM ON THISFLOOR.MANUAL OVERRIDE FOR STAIRWELL LOCATED ON FIRST FLOOR.123
W/D
W/D
DNUP53.16.12.1DC.1ECCBB8.1941.1A78610W01W01B22AEB22B22AEB26B26B26B22EB06E1W01W01W01W01W01W013X03X01X03X01LDM1OSOS3X02B06EB06B06EB06B06EB06B06B06EB06B06EB06B06EB06B06EB063W01W01H41-1H41-1H41-1H41-1H41-1H41-1 H41-1H41-1H41-1H41-1H41-1H41-1H41-1H41-1H41-1H41-1H41-1H41-1H41-1H41-1H41-1H41-1H41-1H41-1H41-1H41-1H41-1H41-1L41-8L41-8L41-8L41-8L41-8L41-8L41-8L41-8L41-8L41-8W48EH11-9111ELEV. 1113ELEV. 2417ELEVATOR LOBBY409LINENS &HOUSEKEEPING140LINEN CHUTE407EFFICIENCY409APANELS406STAIR 1408EFFICIENCY405EFFICIENCY403EFFICIENCYENLARGED401KING 1-BEDROOMENLARGED402KING1-BEDROOM404KING STUDIO410DOUBLE QUEEN412DOUBLE QUEENADA-M-T414KING STUDIO416KING STUDIO418KING STUDIO400CONNECTINGCORRIDOR401ABALCONY402ABALCONY409BIDF409CDAC12LDM1LDMV1TYP H41BRDG3415GUEST CORRIDOR54C48EC48C48EC48EC48C48C48EC48H41-1H41-1H41-1H41-1H41-1H41-1H41-1H41-1W48EH11-9312E32 MERCHANT STREET, SUITE 208HONOLULU, HI 96813808-352-5299OWNER:HOMEWOOD SUITES by HILTON
SPOKANE VALLEY, WA
13515 E. Carlisle Avenue
Spokane Valley, WA 99216FSC PROJECT NO. 21012PERMITDOCUMENTSMay 31, 2024GL8 MirabeauPoint, LLCTMK:PID: 45101.0401 10909 E. Pierce LaneSpokane, WA 99206(509) 919-0901Revision ScheduleNumber Description Date5915 S REGAL STREETSUITE 201SPOKANE, WA 99223PH: 509.473.9218Kelly@kwrllc.comwww.kwrllc.com5/30/2024 12:50:54 PMSTATE OF WASHINGTONREGISTERED PROFESSIONAL ENG
INEER48350 KELLY A
N
DREW WATERMAN05.31.24FOURTH FLOORLIGHTING PLAN -AREA AE-204ASCALE:1/8" = 1'-0"FOURTH FLOOR LIGHTING PLAN - AREA ASHEET E-204A
SHEET E-204B
SHEET E-204A
SHEET E-204B
GENERAL NOTESA. PROVIDE UN-SWITCHED HOT CONDUCTOR TO ALL EMERGENCY LUMINAIRESAND EXIT SIGNS. EMERGENCY LUNIMAIRES ARE INDICATED BY HATCHINGAND/OR WITH AN 'E' DESIGNATION ON THE END OF FIXTURE NAME.B. PROVIDE ALL HARDWARE AND ACCESSORIES REQUIRED TO MOUNTLUMINAIRE IN LOCATIONS SHOWN INCLUDING ALL MOUNTING BRACKETS,T-BAR HANGERS, CANOPIES, ETC.C. LIGHTING CONTROLS BASIS OF DESIGN IS A DIGITAL DISTRIBUTED,NETWORKABLE SYSTEM CONSISTING OF CONTROL/DIMMING MODULES ANDBOTH MANUAL AND AUTOMATIC INPUT DEVICES (OCCUPANCY SENSORS,DAYLIGHT SENSORS, AND MANUAL CONTROL STATIONS. EACH SPACE SHALLCONSIST OF A LOCAL LIGHTING CONTROL NETWORK, WITH ALL CONTROLDEVICES IN THE SPACE CONNECTED TOGETHER VIA CAT-5E NETWORK IN ADAISY CHAIN TOPOLOGY. EACH SPACE SHALL HAVE A NETWORK HOME RUNOF CAT-5E CABLE THAT TERMINATES ON A DEDICATED BRIDGE PORT ON THENEAREST NETWORK BRIDGE. INTERIOR AND EXTERIOR LIGHTING ZONESSHALL TERMINATE ON DEDICATED NETWORK BRIDGES OR BRIDGE HUBS.ACTUAL QUANTITY OF BRIDGES NOT SHOWN AND SHALL BE DETERMINED ONMANUFACTURER'S SHOP DRAWINGS.D. ALL OCCUPANCY SENSORS SHALL BE SET TO A DEFAULT TIME DELAY OF 15MINUTES. OCCUPANCY SENSORS IN RESTROOMS AND CORRIDORS SHALL BESET TO AUTO ON, AUTO OFF. ALL OTHER OCCUPANCY SENSORS SHALL BESET TO MANUAL ON, AUTO OFF UNLESS OTHERWISE NOTED.FLAG NOTESMOUNT LIGHTING CONTROL MODULE TO JUNCTION BOX ABOVE ACCESSIBLE CEILING.CONNECT UN-SWITCHED CIRCUIT TO LINE SIDE OF MODULE AND EXTEND SWITCHEDCIRCUIT AND 0-10V DIMMING CIRCUIT TO LIGHTING ZONES INDICATED. IN AREASWITH INACCESSIBLE CEILINGS, LOCATE DEVICES IN NEAREST ADJACENT ACCESSIBLECEILING OR NON-PUBLIC UTILITY SPACE. DEVICES SHALL BE LOCATEDCONSISTENTLY FOR SIMILAR SPACES (I.E. ABOVE DOORS IN OFFICES).MOUNT BRIDGE DEVICE ABOVE ACCESSIBLE CEILING. BRIDGE TO RECEIVE HOMERUNS FROM LOCAL LIGHTING CONTROL NETWORK DAISY CHAINS IN ADJACENTAREAS. NOT ALL BRIDGES ARE SHOWN, PROVIDE BRIDGES AS REQUIRED TO ACCEPTA DEDICATED LOCAL NETWORK HOMERUN FROM EACH SPACE. REFER TOMANUFACTURER'S SHOP DRAWINGS FOR FINAL QUANTITIES.LIGHTING CONTROLS IN THIS SPACE SHALL UTILIZE TIME-BASED AUTOMATICCONTROL BASED ON BUSINESS HOURS DEFINED BY THE OWNER DURING STARTUP.LIGHTING CONTROL MODULES AND DEVICES TO BE CONNECTED TO DIGITALLIGHTING CONTROL NETWORK TO OBTAIN TIME-CLOCK SIGNAL.MANUAL OVERRIDE / DIMMING CONTROL STATION FOR CORRIDOR AND ELEVATORLOBBY LIGHTING THROUGHOUT THIS FLOOR.MANUAL OVERRIDE FOR STAIRWELL LOCATED ON FIRST FLOOR.12345
DNUPLW011X03X01X011X02B06B06B06EB06EB06EB06B06EB06B06EB06B06EB06B06EB06B06EB06W01W01W01W01W01W01W01W01W01W48EH41-1H41-1H41-1H41-1H12-1H41-1H41-1H41-1H41-1H41-1H41-1H41-1H41-1H41-1H41-1H41-1H41-1H41-1H41-1H41-1H41-1L41-8L41-8L41-8L41-8L41-8L41-8L41-8L41-8L41-8L41-8415AELECTRICAL420KING STUDIO426KING STUDIO430KING STUDIO438KING STUDIOADA-M-RI419KING STUDIO421KING STUDIO423KING STUDIO425KING STUDIO427EFFICIENCY429EFFICIENCY431EFFICIENCY433EFFICIENCY437KING STUDIO435DOUBLE QUEEN432STAIR 2428EFFICIENCY434EFFICIENCY436DOUBLE QUEEN424DOUBLE QUEEN422DOUBLE QUEEN415GUEST CORRIDOR435ABALCONY437ABALCONY425ABALCONY423ABALCONY421ABALCONY419ABALCONY23W48EH12-156.18.1978610FGHML.1KNPQJE32 MERCHANT STREET, SUITE 208HONOLULU, HI 96813808-352-5299OWNER:HOMEWOOD SUITES by HILTON
SPOKANE VALLEY, WA
13515 E. Carlisle Avenue
Spokane Valley, WA 99216FSC PROJECT NO. 21012PERMITDOCUMENTSMay 31, 2024GL8 MirabeauPoint, LLCTMK:PID: 45101.0401 10909 E. Pierce LaneSpokane, WA 99206(509) 919-0901Revision ScheduleNumber Description Date5915 S REGAL STREETSUITE 201SPOKANE, WA 99223PH: 509.473.9218Kelly@kwrllc.comwww.kwrllc.com5/30/2024 12:51:05 PMSTATE OF WASHINGTONREGISTERED PROFESSIONAL ENG
INEER48350 KELLY A
N
DREW WATERMAN05.31.24FOURTH FLOORLIGHTING PLAN -AREA BE-204BSCALE:1/8" = 1'-0"FOURTH FLOOR LIGHTING PLAN - AREA BSHEET E-204ASHEET E-204BSHEET E-204ASHEET E-204B
GENERAL NOTESA. PROVIDE UN-SWITCHED HOT CONDUCTOR TO ALL EMERGENCY LUMINAIRESAND EXIT SIGNS. EMERGENCY LUNIMAIRES ARE INDICATED BY HATCHINGAND/OR WITH AN 'E' DESIGNATION ON THE END OF FIXTURE NAME.B. PROVIDE ALL HARDWARE AND ACCESSORIES REQUIRED TO MOUNTLUMINAIRE IN LOCATIONS SHOWN INCLUDING ALL MOUNTING BRACKETS,T-BAR HANGERS, CANOPIES, ETC.C. LIGHTING CONTROLS BASIS OF DESIGN IS A DIGITAL DISTRIBUTED,NETWORKABLE SYSTEM CONSISTING OF CONTROL/DIMMING MODULES ANDBOTH MANUAL AND AUTOMATIC INPUT DEVICES (OCCUPANCY SENSORS,DAYLIGHT SENSORS, AND MANUAL CONTROL STATIONS. EACH SPACE SHALLCONSIST OF A LOCAL LIGHTING CONTROL NETWORK, WITH ALL CONTROLDEVICES IN THE SPACE CONNECTED TOGETHER VIA CAT-5E NETWORK IN ADAISY CHAIN TOPOLOGY. EACH SPACE SHALL HAVE A NETWORK HOME RUNOF CAT-5E CABLE THAT TERMINATES ON A DEDICATED BRIDGE PORT ON THENEAREST NETWORK BRIDGE. INTERIOR AND EXTERIOR LIGHTING ZONESSHALL TERMINATE ON DEDICATED NETWORK BRIDGES OR BRIDGE HUBS.ACTUAL QUANTITY OF BRIDGES NOT SHOWN AND SHALL BE DETERMINED ONMANUFACTURER'S SHOP DRAWINGS.D. ALL OCCUPANCY SENSORS SHALL BE SET TO A DEFAULT TIME DELAY OF 15MINUTES. OCCUPANCY SENSORS IN RESTROOMS AND CORRIDORS SHALL BESET TO AUTO ON, AUTO OFF. ALL OTHER OCCUPANCY SENSORS SHALL BESET TO MANUAL ON, AUTO OFF UNLESS OTHERWISE NOTED.FLAG NOTESLIGHTING CONTROLS IN THIS SPACE SHALL UTILIZE TIME-BASED AUTOMATICCONTROL BASED ON BUSINESS HOURS DEFINED BY THE OWNER DURING STARTUP.LIGHTING CONTROL MODULES AND DEVICES TO BE CONNECTED TO DIGITALLIGHTING CONTROL NETWORK TO OBTAIN TIME-CLOCK SIGNAL.MANUAL OVERRIDE FOR THIS SPACE LOCATED IN HOUSEKEEPING ROOM ON THISFLOOR.MANUAL OVERRIDE FOR STAIRWELL LOCATED ON FIRST FLOOR.123
W/D
W/D
DN53.16.12.1DC.1ECCBB8.1941.1A78610NEMA 4XNEMA 4XG02EG02EG02EG02EW01W01B22AEB22B22AEB26B26B26B22EB06E1W01W01W01W01W01W012X03X01X03X01LDM1OSOS2X02B06EB06B06EB06B06EB06B06B06EB06B06EB06B06EB06B06EB062W01W01W48EH41-3H41-3H41-3H41-3H41-3H41-3H41-3H41-3H41-3ELEV-5ELEV-5ELEV-5ELEV-5H41-3H41-3H41-3H41-3H41-3H41-3H41-3H41-3H41-3H41-3H41-3H41-3H41-3H41-3H41-3H41-3H11-9H41-3H41-3H41-3L51-20L51-20L51-20L51-20L51-20L51-20L51-20L51-20L51-20L51-20ELEV111ELEV. 1113ELEV. 2517ELEVATOR LOBBY140LINEN CHUTE509APANELS506STAIR 1508EFFICIENCY505EFFICIENCY503EFFICIENCYADA-M-T501KING 1-BEDROOMENLARGED502KING1-BEDROOM504KING STUDIO510DOUBLE QUEEN512DOUBLE QUEENENLARGED514KING STUDIO516KING STUDIO518KING STUDIO500CONNECTINGCORRIDOR507EFFICIENCY509LINENS &HOUSEKEEPING509BIDF509CDAC501ABALCONY502ABALCONY13LDM1LDMV1TYP 2515GUEST CORRIDORL514C48EC48C48EC48EC48C48C48EC48H41-3H41-3H41-3H41-3H41-3H41-3H41-3H41-3W48EH11-95TYP.E31232 MERCHANT STREET, SUITE 208HONOLULU, HI 96813808-352-5299OWNER:HOMEWOOD SUITES by HILTON
SPOKANE VALLEY, WA
13515 E. Carlisle Avenue
Spokane Valley, WA 99216FSC PROJECT NO. 21012PERMITDOCUMENTSMay 31, 2024GL8 MirabeauPoint, LLCTMK:PID: 45101.0401 10909 E. Pierce LaneSpokane, WA 99206(509) 919-0901Revision ScheduleNumber Description Date5915 S REGAL STREETSUITE 201SPOKANE, WA 99223PH: 509.473.9218Kelly@kwrllc.comwww.kwrllc.com5/30/2024 12:51:14 PMSTATE OF WASHINGTONREGISTERED PROFESSIONAL ENG
INEER48350 KELLY A
N
DREW WATERMAN05.31.24FIFTH FLOORLIGHTING PLAN -AREA AE-205ASCALE:1/8" = 1'-0"FIFTH FLOOR LIGHTING PLAN - AREA ASHEET E-205A
SHEET E-205B
SHEET E-205A
SHEET E-205B
GENERAL NOTESA. PROVIDE UN-SWITCHED HOT CONDUCTOR TO ALL EMERGENCY LUMINAIRESAND EXIT SIGNS. EMERGENCY LUNIMAIRES ARE INDICATED BY HATCHINGAND/OR WITH AN 'E' DESIGNATION ON THE END OF FIXTURE NAME.B. PROVIDE ALL HARDWARE AND ACCESSORIES REQUIRED TO MOUNTLUMINAIRE IN LOCATIONS SHOWN INCLUDING ALL MOUNTING BRACKETS,T-BAR HANGERS, CANOPIES, ETC.C. LIGHTING CONTROLS BASIS OF DESIGN IS A DIGITAL DISTRIBUTED,NETWORKABLE SYSTEM CONSISTING OF CONTROL/DIMMING MODULES ANDBOTH MANUAL AND AUTOMATIC INPUT DEVICES (OCCUPANCY SENSORS,DAYLIGHT SENSORS, AND MANUAL CONTROL STATIONS. EACH SPACE SHALLCONSIST OF A LOCAL LIGHTING CONTROL NETWORK, WITH ALL CONTROLDEVICES IN THE SPACE CONNECTED TOGETHER VIA CAT-5E NETWORK IN ADAISY CHAIN TOPOLOGY. EACH SPACE SHALL HAVE A NETWORK HOME RUNOF CAT-5E CABLE THAT TERMINATES ON A DEDICATED BRIDGE PORT ON THENEAREST NETWORK BRIDGE. INTERIOR AND EXTERIOR LIGHTING ZONESSHALL TERMINATE ON DEDICATED NETWORK BRIDGES OR BRIDGE HUBS.ACTUAL QUANTITY OF BRIDGES NOT SHOWN AND SHALL BE DETERMINED ONMANUFACTURER'S SHOP DRAWINGS.D. ALL OCCUPANCY SENSORS SHALL BE SET TO A DEFAULT TIME DELAY OF 15MINUTES. OCCUPANCY SENSORS IN RESTROOMS AND CORRIDORS SHALL BESET TO AUTO ON, AUTO OFF. ALL OTHER OCCUPANCY SENSORS SHALL BESET TO MANUAL ON, AUTO OFF UNLESS OTHERWISE NOTED.FLAG NOTESMOUNT LIGHTING CONTROL MODULE TO JUNCTION BOX ABOVE ACCESSIBLE CEILING.CONNECT UN-SWITCHED CIRCUIT TO LINE SIDE OF MODULE AND EXTEND SWITCHEDCIRCUIT AND 0-10V DIMMING CIRCUIT TO LIGHTING ZONES INDICATED. IN AREASWITH INACCESSIBLE CEILINGS, LOCATE DEVICES IN NEAREST ADJACENT ACCESSIBLECEILING OR NON-PUBLIC UTILITY SPACE. DEVICES SHALL BE LOCATEDCONSISTENTLY FOR SIMILAR SPACES (I.E. ABOVE DOORS IN OFFICES).LIGHTING CONTROLS IN THIS SPACE SHALL UTILIZE TIME-BASED AUTOMATICCONTROL BASED ON BUSINESS HOURS DEFINED BY THE OWNER DURING STARTUP.LIGHTING CONTROL MODULES AND DEVICES TO BE CONNECTED TO DIGITALLIGHTING CONTROL NETWORK TO OBTAIN TIME-CLOCK SIGNAL.MANUAL OVERRIDE / DIMMING CONTROL STATION FOR CORRIDOR AND ELEVATORLOBBY LIGHTING THROUGHOUT THIS FLOOR.MANUAL OVERRIDE FOR STAIRWELL LOCATED ON FIRST FLOOR.COORDINATE FINAL LOCATION OF LUMINAIRE(S) IN TOP OF ELEVATOR SHAFT WITHELEVATOR INSTALLER PRIOR TO ROUGH-IN.12345
DNLW011X03X01X011X02B06B06B06EB06EB06EB06B06EB06B06EB06B06EB06B06EB06B06EB06W01W01W01W01W01W01W01W01W01W48EH41-3H41-3H41-3H41-3H12-1H41-3H41-3H41-3H41-3H41-3H41-3H41-3H41-3H41-3H41-3H41-3H41-3H41-3H41-3H41-3H41-3L51-20L51-20L51-20L51-20L51-20L51-20L51-20L51-20L51-20L51-20515AELECTRICAL520KING STUDIO526KING STUDIO530KING STUDIO538KING STUDIOENLARGED519KING STUDIO521KING STUDIO523KING STUDIO525KING STUDIO527EFFICIENCY529EFFICIENCY531EFFICIENCY533EFFICIENCY537KING STUDIO535DOUBLE QUEEN532STAIR 2528EFFICIENCY534EFFICIENCY536DOUBLE QUEEN524DOUBLE QUEEN522DOUBLE QUEEN515GUEST CORRIDOR535ABALCONY537ABALCONY525ABALCONY523ABALCONY521ABALCONY519ABALCONY23W48EH12-156.18.1978610FGHML.1KNPQJE32 MERCHANT STREET, SUITE 208HONOLULU, HI 96813808-352-5299OWNER:HOMEWOOD SUITES by HILTON
SPOKANE VALLEY, WA
13515 E. Carlisle Avenue
Spokane Valley, WA 99216FSC PROJECT NO. 21012PERMITDOCUMENTSMay 31, 2024GL8 MirabeauPoint, LLCTMK:PID: 45101.0401 10909 E. Pierce LaneSpokane, WA 99206(509) 919-0901Revision ScheduleNumber Description Date5915 S REGAL STREETSUITE 201SPOKANE, WA 99223PH: 509.473.9218Kelly@kwrllc.comwww.kwrllc.com5/30/2024 12:51:25 PMSTATE OF WASHINGTONREGISTERED PROFESSIONAL ENG
INEER48350 KELLY A
N
DREW WATERMAN05.31.24FIFTH FLOORLIGHTING PLAN -AREA BE-205BSCALE:1/8" = 1'-0"FIFTH FLOOR LIGHTING PLAN - AREA BSHEET E-205ASHEET E-205BSHEET E-205ASHEET E-205B
GENERAL NOTESA. PROVIDE UN-SWITCHED HOT CONDUCTOR TO ALL EMERGENCY LUMINAIRESAND EXIT SIGNS. EMERGENCY LUNIMAIRES ARE INDICATED BY HATCHINGAND/OR WITH AN 'E' DESIGNATION ON THE END OF FIXTURE NAME.B. PROVIDE ALL HARDWARE AND ACCESSORIES REQUIRED TO MOUNTLUMINAIRE IN LOCATIONS SHOWN INCLUDING ALL MOUNTING BRACKETS,T-BAR HANGERS, CANOPIES, ETC.C. LIGHTING CONTROLS BASIS OF DESIGN IS A DIGITAL DISTRIBUTED,NETWORKABLE SYSTEM CONSISTING OF CONTROL/DIMMING MODULES ANDBOTH MANUAL AND AUTOMATIC INPUT DEVICES (OCCUPANCY SENSORS,DAYLIGHT SENSORS, AND MANUAL CONTROL STATIONS. EACH SPACE SHALLCONSIST OF A LOCAL LIGHTING CONTROL NETWORK, WITH ALL CONTROLDEVICES IN THE SPACE CONNECTED TOGETHER VIA CAT-5E NETWORK IN ADAISY CHAIN TOPOLOGY. EACH SPACE SHALL HAVE A NETWORK HOME RUNOF CAT-5E CABLE THAT TERMINATES ON A DEDICATED BRIDGE PORT ON THENEAREST NETWORK BRIDGE. INTERIOR AND EXTERIOR LIGHTING ZONESSHALL TERMINATE ON DEDICATED NETWORK BRIDGES OR BRIDGE HUBS.ACTUAL QUANTITY OF BRIDGES NOT SHOWN AND SHALL BE DETERMINED ONMANUFACTURER'S SHOP DRAWINGS.D. ALL OCCUPANCY SENSORS SHALL BE SET TO A DEFAULT TIME DELAY OF 15MINUTES. OCCUPANCY SENSORS IN RESTROOMS AND CORRIDORS SHALL BESET TO AUTO ON, AUTO OFF. ALL OTHER OCCUPANCY SENSORS SHALL BESET TO MANUAL ON, AUTO OFF UNLESS OTHERWISE NOTED.FLAG NOTESLIGHTING CONTROLS IN THIS SPACE SHALL UTILIZE TIME-BASED AUTOMATICCONTROL BASED ON BUSINESS HOURS DEFINED BY THE OWNER DURING STARTUP.LIGHTING CONTROL MODULES AND DEVICES TO BE CONNECTED TO DIGITALLIGHTING CONTROL NETWORK TO OBTAIN TIME-CLOCK SIGNAL.MANUAL OVERRIDE FOR THIS SPACE LOCATED IN HOUSEKEEPING ROOM ON THISFLOOR.MANUAL OVERRIDE FOR STAIRWELL LOCATED ON FIRST FLOOR.123
DNFDFDD D D DWWWWUP533.16.12.1DC.1ECCBB18.1941.1AA786101E-501TVT1T2CAHPT2USBCA+60"+60"USBUSBHPT2+60"+60"+44"USBUSBUSB+44"USBRCM
+44"+44"+44"+44"HP+44"HPHPNEMA 4XNEMA 4X+80"+60"DF-1HPT21A104ELECTRICAL101POOL/SPLASHPAD102POOL RESTROOM100PUBLIC CORRIDOR108WATER HEATER& FIRE105BOH LAUNDRY107LINEN DISCHARGE& SORTING110EMPLOYEEROOM112LAUNDRYLOUNGE110AEMP RR ADA140LINEN CHUTE111ELEV 1113ELEV 2109LINEN STORAGE110BEMP RR114FITNESS116MEN'SRESTROOM115WOMEN'SRESTROOM119MEETINGSTORAGE120MEETING ROOM118GUEST STORAGE106STAIR 1117ELEVATOR LOBBY103POOL MEP+44"+44"WPWPWPWPWPWPFCU-212FCU-211FCU-213USBWPWPBCU-1T2RCM100AVESTIBULE109AHOUSEKEEPINGOFFICESSSS+60"TVT1TVT1ICE-1HPT1TVT1TVT1TVT1BIKE-1TREAD-1TREAD-2TREAD-3TREAD-4ELLIP-1ELLIP-2CA1CACACADRY-1.1DRY-1.2DRY-1.3DRY-1.4WASH-1.1WASH-1.2WASH-1.3WASH-1.4WASH-2.1WASH-2.2WASH-2.3DRY-2.1DRY-2.2DRY-2.3FCU-311FCU-214EH-11SMOKE DAMPERSMOKE DAMPER1TYP233SP-1NEMA 4XSP-2NEMA 4XWH-1WH-2WH-3FSFSTSTSFACPWH-4WS-01DHWP-1DHWP-24L11-1,3,5L11-7,9,11L11-13,15,17L11-2,4,6L11-8,10,12L11-14,16,18L11-19L11-21L11-23L11-25L11-20,22L11-24,26L11-28,30L11-32,34REF-1DW-1MW-1+44"L11-27L11-29L11-31L11-33L11-35L11-37L11-39L11-36L11-36L11-36L11-38+44"+44"L12-1L12-3L12-5L12-7L12-8L12-10L12-12L12-14L12-9,11L12-9,11L12-9,11L11-40ELEV-2ELEV-4L12-16,18L12-16,18L12-16,18L12-13L12-13HPWPWP5LPAT-8LPAT-8LPAT-8LPAT-8LPAT-8L1P-2L1P-2L12-20L12-20L12-20L12-22L12-22L12-22L12-22L12-22L12-24L12-24L12-24L12-26L12-26L12-26L12-26L12-26L12-26L12-28L12-28L12-28L12-28L12-30L12-30L12-30L12-30L12-30L12-30L12-32L12-32L12-32L12-32L12-32L12-34L12-34L12-21L12-21L12-21L12-23L12-23L12-23L12-23L12-25L12-25L12-25L12-25L12-25L12-27L12-27L12-27L12-27L12-29L12-31ELEV-1ELEV-1L12-24L12-24L12-24L1P-2105ABOH DRYER22222B6WPL12-392ESDCRXESDCRXESDCRXESDCRXSESDCRX1E-702ESDCRXMAG HOLDM7L12-41FACPL12-40E32 MERCHANT STREET, SUITE 208HONOLULU, HI 96813808-352-5299OWNER:HOMEWOOD SUITES by HILTON
SPOKANE VALLEY, WA
13515 E. Carlisle Avenue
Spokane Valley, WA 99216FSC PROJECT NO. 21012PERMITDOCUMENTSMay 31, 2024GL8 MirabeauPoint, LLCTMK:PID: 45101.0401 10909 E. Pierce LaneSpokane, WA 99206(509) 919-0901Revision ScheduleNumber Description Date5915 S REGAL STREETSUITE 201SPOKANE, WA 99223PH: 509.473.9218Kelly@kwrllc.comwww.kwrllc.com5/30/2024 12:51:33 PMSTATE OF WASHINGTONREGISTERED PROFESSIONAL ENG
INEER48350 KELLY A
N
DREW WATERMAN05.31.24FIRST FLOORELECTRICAL PLAN -AREA AE-301AGENERAL NOTESA. COORDINATE WITH MECHANICAL, PRIOR TO ROUGH-IN, FOR FINAL EQUIPMENT INSTALL LOCATIONS AND CONNECTION REQUIREMENTS.B. COORDINATE RECEPTACLE MOUNTING HEIGHTS IN ALL KITCHEN ANDBREAK ROOM AREAS TO AVOID CONFLICTS WITH KITCHENEQUIPMENT, COUNTERS, BACKSPLASH, AND FURNITURE.C. LOW-VOLTAGE CABLES MAY BE RUN OPEN AIR IN ACCESSIBLECEILING SPACES ABOVE SUSPENDED ACOUSTICAL CEILING TILEGRIDS. ROUTE CABLES IN CONDUIT THROUGH INACCESSIBLECEILING AREAS (I.E. HARD LID) AND WHERE EXPOSED TOSTRUCTURE.D. MAINTAIN 36" WORKING CLEARANCE IN FRONT OF ELECTRICALPANELS PER NEC REQUIREMENTS.E. GUEST UNIT DEVICE LAYOUTS NOT SHOWN ON THIS SHEET FORCLARITY. SEE SHEET E5.02 AND E5.03 FOR ENLARGED TYPICALGUEST UNIT DEVICE LAYOUTS. SEE ARCHITECTURAL PLANS FORQUANITIES AND LOCATIONS OF TYPICAL GUEST UNIT TYPES.F. FIRE ALARM SYSTEM DEVICE LAYOUT SHOWS OWNER'S MINIMUMREQUIREMENTS. FIRE ALARM SYSTEM TO BE DESIGNED BYCERTIFIED FIRE ALARM DESIGNER AND APPROVED BY AHJ PRIOR TOORDERING AND INSTALLATION.G. SEE ARCHITECTURAL FLOOR PLANS FOR DIMENSIONED LOCATIONSOF ALL FLOOR BOXESFLAG NOTESPROVIDE RECEPTACLE CONTROL MODULE (RCM) FOR AUTOMATICTIME BASED CONTROL WITH OCCUPANCY OVERRIDES OF INDICATEDRECEPTACLES IN THIS SPACE (UNLESS OTHERWISE NOTED). LOCATEABOVE ACCESSIBLE CEILING OR AGAINST CEILING ADJACENT TOLIGHTING CONTROL MODULE. IN OPEN-TO-STRUCTURE AREAS,LOCATE DEVICES TIGHT TO CEILING STRUCTURE AND PAINT TOMATCH SURROUNDING. CONNECT RCM TO LOCAL LIGHTINGCONTROL NETWORK VIA CAT-5E NETWORK CABLE.GFCI PROTECTION PROVIDED BY CIRCUIT BREAKER. SEE PANELSCHEDULES FOR ADDITIONAL INFORMATION.PROVIDE 120V CONNECTIONS AND FIRE ALARM CONNECTION FORFIRE SMOKE DAMPERS IN MECHANICAL CHASE/DUCTWORK IN THISAPPROXIMATE LOCATION. SEE MECHANICAL PLANS FOR EXACTLOCATIONS. PROVIDE DUCT SMOKE DETECTORS AT SMOKE DAMPERLOCATIONS AS SHOWN. VERIFY CONNECTION REQUIREMENTS WITHMECHANICAL PRIOR TO ROUGH-IN.FLOW AND TAMPER SWITCHES FOR MONITORING FIRE SUPPRESSIONRISER. COORDINATE FINAL QUANTITY, 120V POWER REQUIREMENTSFOR FIRE ALARM EQUIPMENT AND SPRINKLER ALARM BELL WITHSELECTED VENDOR.POOL EQUIPMENT AND ASSOCIATED BRANCH CIRCUITING IN THISWILL BE ADDED AS PART OF A DEFERRED SUBMITTAL. PANEL L1PINTENDED AS BRANCH PANELBOARD DEDICATED TO POOLEQUIPMENT.SPRINKLER ALARM / FLOW BELL. MOUNTING LOCATION AND HEIGHTTO BE DETERMINED BY SPRINKLER INSTALLER. PROVIDE 120VBRANCH CIRCUIT AS NOTED.VERIFY EXACT CONNECTION LOCATIONS AND REQUIREMENTS WITHDOOR HARDWARE PROVIDER.1SCALE:1/8" = 1'-0"FIRST FLOOR ELECTRICAL PLAN - AREA ASHEET E-301A
SHEET E-301B
SHEET E-301A
SHEET E-301B
234567
UPML.1EKNPQ2JL2E-501COPY-1T2T2HP1111+48"+48"DF-21T2+96"+96"USBUSBUSBT4T4T4RCMRCMRCMT4T4RCMRCMRCMFIREPLACE IGNITERFIREPLACE IGNITER11MEETING ROOM121LOBBY122VESTIBULE123FOOD PREP128ELECTRICAL124OPEN OFFICE126SALES OFFICE125GM OFFICE127OWNER'S OFFICE132STAIR 2139GUEST CORRIDOR139BELECTRICAL130KING STUDIO134EFFICIENCY136DOUBLE QUEEN138KING STUDIOADA-M-T129EFFICIENCY131EFFICIENCY133EFFICIENCY135DOUBLE QUEEN137KING STUDIO141COURTYARDSTORAGEX-SDP12SDP12L14AL14BH12WPWPWPWPWPWPWPUSBUSBDOOR MOTORDOOR MOTORL16FCU-215FCU-217WP139AVESTIBULELPATFAA121APUBLIC CORRIDORHSSSSS11CACAT211PRINT-1H11KE-56KE-29KE-30KE-60EH-12L14A-1,3L14A-1,3L14A-2L14A-4L14A-6L14A-5KE-61AKE-61CKE-61DKE-96AKE-96BKE-98LPAT-1LPAT-3LPAT-5LPAT-2LPAT-2LPAT-4LPAT-4L1KA-21L1KA-25L1KA-27L1KA-16L1KA-18L1KA-20,22L1KA-24KE-61BL1KA-23ICAVLPAT-6LPAT-6LPAT-6LPAT-6LPAT-6L12-27L12-27L12-29L12-31RCML14A-8L14A-10L14A-10L14A-12L14A-12L14A-14L14A-14L14A-16L14A-16L14A-16L14A-16L14A-16L14A-18L14A-18L14A-18L14A-18L14A-20L14A-20L14A-20L14A-7L14A-7L14A-28L14A-28L14A-28L14A-28L14A-28L14A-28L14A-9L14A-11L14A-13L14A-15L14A-17L14A-19L14A-19L14A-19L14A-19L14A-19L14A-19L14A-21L14A-21L14A-21L14A-21L14A-23L14A-23L14A-23L14A-23L14A-25L14A-25L14A-25L14A-25L14A-27L14A-27L14A-29L14A-29333E-501MOTORIZED SHADEST1CC4L12-3721TYP55MAG HOLDL14A-316EF-03NEMA 3RL1KA-38,40ESDCRXESDCRXESDCESDCRXMFGH8.19781043156E1132 MERCHANT STREET, SUITE 208HONOLULU, HI 96813808-352-5299OWNER:HOMEWOOD SUITES by HILTON
SPOKANE VALLEY, WA
13515 E. Carlisle Avenue
Spokane Valley, WA 99216FSC PROJECT NO. 21012PERMITDOCUMENTSMay 31, 2024GL8 MirabeauPoint, LLCTMK:PID: 45101.0401 10909 E. Pierce LaneSpokane, WA 99206(509) 919-0901Revision ScheduleNumber Description Date5915 S REGAL STREETSUITE 201SPOKANE, WA 99223PH: 509.473.9218Kelly@kwrllc.comwww.kwrllc.com5/30/2024 12:51:43 PMSTATE OF WASHINGTONREGISTERED PROFESSIONAL ENG
INEER48350 KELLY A
N
DREW WATERMAN05.31.24FIRST FLOORELECTRICAL PLAN -AREA BE-301BFLAG NOTESSHEET E-301ASHEET E-301BSHEET E-301ASHEET E-301B
GENERAL NOTESA. COORDINATE WITH MECHANICAL, PRIOR TO ROUGH-IN, FOR FINAL EQUIPMENT INSTALL LOCATIONS AND CONNECTION REQUIREMENTS.B. COORDINATE RECEPTACLE MOUNTING HEIGHTS IN ALL KITCHEN ANDBREAK ROOM AREAS TO AVOID CONFLICTS WITH KITCHENEQUIPMENT, COUNTERS, BACKSPLASH, AND FURNITURE.C. LOW-VOLTAGE CABLES MAY BE RUN OPEN AIR IN ACCESSIBLECEILING SPACES ABOVE SUSPENDED ACOUSTICAL CEILING TILEGRIDS. ROUTE CABLES IN CONDUIT THROUGH INACCESSIBLECEILING AREAS (I.E. HARD LID) AND WHERE EXPOSED TOSTRUCTURE.D. MAINTAIN 36" WORKING CLEARANCE IN FRONT OF ELECTRICALPANELS PER NEC REQUIREMENTS.E. GUEST UNIT DEVICE LAYOUTS NOT SHOWN ON THIS SHEET FORCLARITY. SEE SHEET E5.02 AND E5.03 FOR ENLARGED TYPICALGUEST UNIT DEVICE LAYOUTS. SEE ARCHITECTURAL PLANS FORQUANITIES AND LOCATIONS OF TYPICAL GUEST UNIT TYPES.F. FIRE ALARM SYSTEM DEVICE LAYOUT SHOWS OWNER'S MINIMUMREQUIREMENTS. FIRE ALARM SYSTEM TO BE DESIGNED BYCERTIFIED FIRE ALARM DESIGNER AND APPROVED BY AHJ PRIOR TOORDERING AND INSTALLATION.G. SEE ARCHITECTURAL FLOOR PLANS FOR DIMENSIONED LOCATIONSOF ALL FLOOR BOXESPROVIDE RECEPTACLE CONTROL MODULE (RCM) FOR AUTOMATICTIME BASED CONTROL WITH OCCUPANCY OVERRIDES OF INDICATEDRECEPTACLES IN THIS SPACE (UNLESS OTHERWISE NOTED). LOCATEABOVE ACCESSIBLE CEILING OR AGAINST CEILING ADJACENT TOLIGHTING CONTROL MODULE. IN OPEN-TO-STRUCTURE AREAS,LOCATE DEVICES TIGHT TO CEILING STRUCTURE AND PAINT TOMATCH SURROUNDING. CONNECT RCM TO LOCAL LIGHTINGCONTROL NETWORK VIA CAT-5E NETWORK CABLE.GFCI PROTECTION PROVIDED BY CIRCUIT BREAKER. SEE PANELSCHEDULES FOR ADDITIONAL INFORMATION.PROVIDE 120V BRANCH CIRCUIT FOR FIREPLACE IGNITER CIRCUIT.EMERGENCY POWER OFF BUTTON BEING PROVIDED AS PART OFFIREPLACE; FIELD COORDINATE EXACT CONNECTION LOCATION ANDROUTE CIRCUIT THROUGH EMERGENCY POWER OFF BUTTON.PROVIDE 120V BRANCH CIRCUIT AND DATA CONNECTION ABOVECEILING FOR POWERED SHADES ALONG WALL IN THIS LOCATION.FIELD COORDINATE WITH OWNER AND SHADES INSTALLER FOREXACT ROUGH-IN LOCATION AND CONNECTION REQUIREMENTS.PROVIDE 120V BRANCH CIRCUIT ABOVE CEILING FOR DOOR MOTOR.COORDINATE WITH DOOR INSTALLER FOR EXACT LOCATION ANDCONNECTION REQUIREMENTS. PROVIDE CONDUIT PATHWAY FROMDOOR MOTOR TO ADA PUSHBUTTON ROUGH-IN LOCATION(S) FORCONTROL CABLING BY DOOR INSTALLER.VERIFY EXACT CONNECTION LOCATIONS AND REQUIREMENTS WITHDOOR HARDWARE PROVIDER. PROVIDE CONNECTION TO FIREALARM SYSTEM FOR MAG HOLD BASED UPON SIGNAL FROMBUILDING FIRE ALARM.123456SCALE:1/8" = 1'-0"FIRST FLOOR ELECRTICAL PLAN - AREA B
W/D
W/D
DNUP53.16.12.1DC.1ECCBB8.1941.1A78610HP111ELEV 1113ELEV 2217ELEVATOR LOBBY209LINENS &HOUSEKEEPING140LINEN CHUTE207ENGINEERINGOFFICE & STORAGE207APBX/MDF209APANELS206STAIR 1208EFFICIENCY205EFFICIENCY203EFFICIENCYENLARGED201KING 1-BEDROOMENLARGED202KING1-BEDROOM204KING STUDIO210DOUBLE QUEEN212DOUBLE QUEENENLARGED214KING STUDIO216KING STUDIO218KING STUDIO200CONNECTINGCORRIDORX-SDP2L21L22L23SDP2T2T2RCMHSSSSSSSSSSSEH-21FCU-324FCU-323FCU-322FCU-321FCU-421NEMA 3REF-02NEMA 3REF-01NEMA 3RSMOKE DAMPERSMOKE DAMPERNEMA 3RL21-1,3L21-1,3L21-1,3L21-1,3L21-1,3L21-2L21-6L21-6L21-8,10L21-12IL21-5L21-5L21-5L21-5L21-7L21-9L21-9L21-9L21-9L21-9L21-11L21-13L21-15 L21-17L21-19L21-21L21-21L21-23L21-23L21-23L21-25L21-25215GUESTCORRIDOR209BIDF209CDAC201ABALCONY202ABALCONYMAG HOLD2L21-271WPL21-29433MM6L21-9DAMPER ACTUATORDAMPER ACTUATOR55L21-12L21-1278312CU-01ACU-01BH1M-2,4,6H1M-8,10,12E32 MERCHANT STREET, SUITE 208HONOLULU, HI 96813808-352-5299OWNER:HOMEWOOD SUITES by HILTON
SPOKANE VALLEY, WA
13515 E. Carlisle Avenue
Spokane Valley, WA 99216FSC PROJECT NO. 21012PERMITDOCUMENTSMay 31, 2024GL8 MirabeauPoint, LLCTMK:PID: 45101.0401 10909 E. Pierce LaneSpokane, WA 99206(509) 919-0901Revision ScheduleNumber Description Date5915 S REGAL STREETSUITE 201SPOKANE, WA 99223PH: 509.473.9218Kelly@kwrllc.comwww.kwrllc.com5/30/2024 12:51:48 PMSTATE OF WASHINGTONREGISTERED PROFESSIONAL ENG
INEER48350 KELLY A
N
DREW WATERMAN05.31.24SECOND FLOORELECTRICAL PLAN -AREA AE-302AFLAG NOTESPROVIDE RECEPTACLE CONTROL MODULE (RCM) FOR AUTOMATICTIME BASED CONTROL WITH OCCUPANCY OVERRIDES OF INDICATEDRECEPTACLES IN THIS SPACE (UNLESS OTHERWISE NOTED). LOCATEABOVE ACCESSIBLE CEILING OR AGAINST CEILING ADJACENT TOLIGHTING CONTROL MODULE. IN OPEN-TO-STRUCTURE AREAS,LOCATE DEVICES TIGHT TO CEILING STRUCTURE AND PAINT TOMATCH SURROUNDING. CONNECT RCM TO LOCAL LIGHTINGCONTROL NETWORK VIA CAT-5E NETWORK CABLE.VERIFY EXACT CONNECTION LOCATIONS AND REQUIREMENTS WITHDOOR HARDWARE PROVIDER.PROVIDE 120V CONNECTIONS AND FIRE ALARM CONNECTION FORFIRE SMOKE DAMPERS IN MECHANICAL CHASE/DUCTWORK IN THISAPPROXIMATE LOCATION. SEE MECHANICAL PLANS FOR EXACTLOCATIONS.PROVIDE HVAC EQUIPMENT MAINTENANCE RECEPTACLE PER NEC210.63. FIELD LOCATE WITHIN 25'-0" OF HVAC EQUIPMENTPROVIDE 120V CONNECTION ADJACENT TO EXHAUST FAN, FORASSOCIATED DAMPER ACTUATOR.PROVIDE (1)2"C ROUTED TO ROOF FOR FUTURE SATELLITE / ISPSERVICE CABLING. FIELD COORDINATE EXACT ROUTING.PROVIDE (3)4"C SLEEVES TO CEILING SPACE BELOW, AND (3)2"C TOIDF CLOSET ABOVE, FOR CABLE ROUTING BETWEEN FLOORS.PROVIDE (3)4"C SLEEVES ABOVE CEILING BETWEEN PBX ROOM ANDIDF CLOSET FOR CABLE ROUTING.1SCALE:1/8" = 1'-0"SECOND FLOOR ELECTRICAL PLAN - AREA ASHEET E-302A
SHEET E-302B
SHEET E-302A
SHEET E-302B
GENERAL NOTESA. COORDINATE WITH MECHANICAL, PRIOR TO ROUGH-IN, FOR FINAL EQUIPMENT INSTALL LOCATIONS AND CONNECTION REQUIREMENTS.B. COORDINATE RECEPTACLE MOUNTING HEIGHTS IN ALL KITCHEN ANDBREAK ROOM AREAS TO AVOID CONFLICTS WITH KITCHENEQUIPMENT, COUNTERS, BACKSPLASH, AND FURNITURE.C. LOW-VOLTAGE CABLES MAY BE RUN OPEN AIR IN ACCESSIBLECEILING SPACES ABOVE SUSPENDED ACOUSTICAL CEILING TILEGRIDS. ROUTE CABLES IN CONDUIT THROUGH INACCESSIBLECEILING AREAS (I.E. HARD LID) AND WHERE EXPOSED TOSTRUCTURE.D. MAINTAIN 36" WORKING CLEARANCE IN FRONT OF ELECTRICALPANELS PER NEC REQUIREMENTS.E. GUEST UNIT DEVICE LAYOUTS NOT SHOWN ON THIS SHEET FORCLARITY. SEE SHEET E5.02 AND E5.03 FOR ENLARGED TYPICALGUEST UNIT DEVICE LAYOUTS. SEE ARCHITECTURAL PLANS FORQUANITIES AND LOCATIONS OF TYPICAL GUEST UNIT TYPES.F. FIRE ALARM SYSTEM DEVICE LAYOUT SHOWS OWNER'S MINIMUMREQUIREMENTS. FIRE ALARM SYSTEM TO BE DESIGNED BYCERTIFIED FIRE ALARM DESIGNER AND APPROVED BY AHJ PRIOR TOORDERING AND INSTALLATION.G. SEE ARCHITECTURAL FLOOR PLANS FOR DIMENSIONED LOCATIONSOF ALL FLOOR BOXES2345678
DNUPFGML.1EKNPQHJL220KING STUDIO226KING STUDIO230KING STUDIO238KING STUDIOADA-M-T219KING STUDIO221KING STUDIO223KING STUDIO225KING STUDIO227EFFICIENCY229EFFICIENCY231EFFICIENCY233EFFICIENCY237KING STUDIO235DOUBLE QUEEN232STAIR 2228EFFICIENCY234EFFICIENCY236DOUBLE QUEEN224DOUBLE QUEEN222DOUBLE QUEEN215AELECTRICALL25L24SSSSSSSSEH-22FCU-326FCU-325L21-1,3L21-1,3L21-4HL21-23L21-25L21-25L21-25L21-25235ABALCONY237ABALCONY225ABALCONY223ABALCONY221ABALCONY219ABALCONY56.18.197861011E32 MERCHANT STREET, SUITE 208HONOLULU, HI 96813808-352-5299OWNER:HOMEWOOD SUITES by HILTON
SPOKANE VALLEY, WA
13515 E. Carlisle Avenue
Spokane Valley, WA 99216FSC PROJECT NO. 21012PERMITDOCUMENTSMay 31, 2024GL8 MirabeauPoint, LLCTMK:PID: 45101.0401 10909 E. Pierce LaneSpokane, WA 99206(509) 919-0901Revision ScheduleNumber Description Date5915 S REGAL STREETSUITE 201SPOKANE, WA 99223PH: 509.473.9218Kelly@kwrllc.comwww.kwrllc.com5/30/2024 12:51:54 PMSTATE OF WASHINGTONREGISTERED PROFESSIONAL ENG
INEER48350 KELLY A
N
DREW WATERMAN05.31.24SECOND FLOORELECTRICAL PLAN -AREA BE-302BSCALE:1/8" = 1'-0"SECOND FLOOR ELECTRICAL PLAN - AREA BSHEET E-302ASHEET E-302BSHEET E-302ASHEET E-302B
GENERAL NOTESA. COORDINATE WITH MECHANICAL, PRIOR TO ROUGH-IN, FOR FINAL EQUIPMENT INSTALL LOCATIONS AND CONNECTION REQUIREMENTS.B. COORDINATE RECEPTACLE MOUNTING HEIGHTS IN ALL KITCHEN ANDBREAK ROOM AREAS TO AVOID CONFLICTS WITH KITCHENEQUIPMENT, COUNTERS, BACKSPLASH, AND FURNITURE.C. LOW-VOLTAGE CABLES MAY BE RUN OPEN AIR IN ACCESSIBLECEILING SPACES ABOVE SUSPENDED ACOUSTICAL CEILING TILEGRIDS. ROUTE CABLES IN CONDUIT THROUGH INACCESSIBLECEILING AREAS (I.E. HARD LID) AND WHERE EXPOSED TOSTRUCTURE.D. MAINTAIN 36" WORKING CLEARANCE IN FRONT OF ELECTRICALPANELS PER NEC REQUIREMENTS.E. GUEST UNIT DEVICE LAYOUTS NOT SHOWN ON THIS SHEET FORCLARITY. SEE SHEET E5.02 AND E5.03 FOR ENLARGED TYPICALGUEST UNIT DEVICE LAYOUTS. SEE ARCHITECTURAL PLANS FORQUANITIES AND LOCATIONS OF TYPICAL GUEST UNIT TYPES.F. FIRE ALARM SYSTEM DEVICE LAYOUT SHOWS OWNER'S MINIMUMREQUIREMENTS. FIRE ALARM SYSTEM TO BE DESIGNED BYCERTIFIED FIRE ALARM DESIGNER AND APPROVED BY AHJ PRIOR TOORDERING AND INSTALLATION.G. SEE ARCHITECTURAL FLOOR PLANS FOR DIMENSIONED LOCATIONSOF ALL FLOOR BOXES
W/D
DNUPW D
Microwave53.16.12.1DC.1ECCBB8.1941.1A78610SDP3X-SDP3L31L32L33HPSSSSSSSSSEH-31FCU-333FCU-332FCU-331SMOKE DAMPERSMOKE DAMPERBCU-2L31-1,3L31-1,3L31-1,3L31-1,3L31-2L31-6L31-6IHL31-5L31-5L31-5L31-5L31-5L31-5L31-7L31-9L31-9L31-9L31-9L31-9111ELEV. 1113ELEV. 2317ELEVATOR LOBBY309LINENS &HOUSEKEEPING140LINEN CHUTE307EFFICIENCY309BIDF309APANELS306STAIR 1308EFFICIENCY305EFFICIENCY303EFFICIENCYENLARGED301KING 1-BEDROOMADA-M-T302KING1-BEDROOM304KING STUDIO310DOUBLE QUEEN312DOUBLE QUEENENLARGED314KING STUDIO316KING STUDIO318KING STUDIO300CONNECTINGCORRIDOR309CDAC301ABALCONY302ABALCONYMAG HOLD1L31-1022MML31-93E31232 MERCHANT STREET, SUITE 208HONOLULU, HI 96813808-352-5299OWNER:HOMEWOOD SUITES by HILTON
SPOKANE VALLEY, WA
13515 E. Carlisle Avenue
Spokane Valley, WA 99216FSC PROJECT NO. 21012PERMITDOCUMENTSMay 31, 2024GL8 MirabeauPoint, LLCTMK:PID: 45101.0401 10909 E. Pierce LaneSpokane, WA 99206(509) 919-0901Revision ScheduleNumber Description Date5915 S REGAL STREETSUITE 201SPOKANE, WA 99223PH: 509.473.9218Kelly@kwrllc.comwww.kwrllc.com5/30/2024 12:51:58 PMSTATE OF WASHINGTONREGISTERED PROFESSIONAL ENG
INEER48350 KELLY A
N
DREW WATERMAN05.31.24THIRD FLOORELECTRICAL PLAN -AREA AE-303AFLAG NOTESVERIFY EXACT CONNECTION LOCATIONS AND REQUIREMENTS WITHDOOR HARDWARE PROVIDER.PROVIDE 120V CONNECTIONS AND FIRE ALARM CONNECTION FORFIRE SMOKE DAMPERS IN MECHANICAL CHASE/DUCTWORK IN THISAPPROXIMATE LOCATION. SEE MECHANICAL PLANS FOR EXACTLOCATIONS.PROVIDE (3)4"C EACH INTO IDF ROOM ABOVE AND BELOW, FORCABLE ROUTING BETWEEN FLOORS.1SCALE:1/8" = 1'-0"THIRD FLOOR ELECTRICAL PLAN - AREA ASHEET E-303A
SHEET E-303B
SHEET E-303A
SHEET E-303B
GENERAL NOTESA. COORDINATE WITH MECHANICAL, PRIOR TO ROUGH-IN, FOR FINAL EQUIPMENT INSTALL LOCATIONS AND CONNECTION REQUIREMENTS.B. COORDINATE RECEPTACLE MOUNTING HEIGHTS IN ALL KITCHEN ANDBREAK ROOM AREAS TO AVOID CONFLICTS WITH KITCHENEQUIPMENT, COUNTERS, BACKSPLASH, AND FURNITURE.C. LOW-VOLTAGE CABLES MAY BE RUN OPEN AIR IN ACCESSIBLECEILING SPACES ABOVE SUSPENDED ACOUSTICAL CEILING TILEGRIDS. ROUTE CABLES IN CONDUIT THROUGH INACCESSIBLECEILING AREAS (I.E. HARD LID) AND WHERE EXPOSED TOSTRUCTURE.D. MAINTAIN 36" WORKING CLEARANCE IN FRONT OF ELECTRICALPANELS PER NEC REQUIREMENTS.E. GUEST UNIT DEVICE LAYOUTS NOT SHOWN ON THIS SHEET FORCLARITY. SEE SHEET E5.02 AND E5.03 FOR ENLARGED TYPICALGUEST UNIT DEVICE LAYOUTS. SEE ARCHITECTURAL PLANS FORQUANITIES AND LOCATIONS OF TYPICAL GUEST UNIT TYPES.F. FIRE ALARM SYSTEM DEVICE LAYOUT SHOWS OWNER'S MINIMUMREQUIREMENTS. FIRE ALARM SYSTEM TO BE DESIGNED BYCERTIFIED FIRE ALARM DESIGNER AND APPROVED BY AHJ PRIOR TOORDERING AND INSTALLATION.G. SEE ARCHITECTURAL FLOOR PLANS FOR DIMENSIONED LOCATIONSOF ALL FLOOR BOXES23
DNUPLL34L35SSSSSSSSEH-32FCU-335FCU-334L31-1,3L31-1,3L31-4HL31-11L31-11L31-11L31-11L31-11315AELECTRICAL320KING STUDIO326KING STUDIO330KING STUDIO338KING STUDIOENLARGED319KING STUDIO321KING STUDIO323KING STUDIO325KING STUDIO327EFFICIENCY329EFFICIENCY331EFFICIENCY333EFFICIENCY337KING STUDIO335DOUBLE QUEEN332STAIR 2328EFFICIENCY334EFFICIENCY336DOUBLE QUEEN324DOUBLE QUEEN322DOUBLE QUEEN339CONNECTINGCORRIDOR315GUEST CORRIDOR335ABALCONY337ABALCONY325ABALCONY323ABALCONY321ABALCONY319ABALCONY56.18.1978610FGHML.1KNPQJE32 MERCHANT STREET, SUITE 208HONOLULU, HI 96813808-352-5299OWNER:HOMEWOOD SUITES by HILTON
SPOKANE VALLEY, WA
13515 E. Carlisle Avenue
Spokane Valley, WA 99216FSC PROJECT NO. 21012PERMITDOCUMENTSMay 31, 2024GL8 MirabeauPoint, LLCTMK:PID: 45101.0401 10909 E. Pierce LaneSpokane, WA 99206(509) 919-0901Revision ScheduleNumber Description Date5915 S REGAL STREETSUITE 201SPOKANE, WA 99223PH: 509.473.9218Kelly@kwrllc.comwww.kwrllc.com5/30/2024 12:52:04 PMSTATE OF WASHINGTONREGISTERED PROFESSIONAL ENG
INEER48350 KELLY A
N
DREW WATERMAN05.31.24THIRD FLOORELECTRICAL PLAN -AREA BE-303BSCALE:1/8" = 1'-0"THIRD FLOOR ELECTRICAL PLAN - AREA BSHEET E-303ASHEET E-303BSHEET E-303ASHEET E-303B
GENERAL NOTESA. COORDINATE WITH MECHANICAL, PRIOR TO ROUGH-IN, FOR FINAL EQUIPMENT INSTALL LOCATIONS AND CONNECTION REQUIREMENTS.B. COORDINATE RECEPTACLE MOUNTING HEIGHTS IN ALL KITCHEN ANDBREAK ROOM AREAS TO AVOID CONFLICTS WITH KITCHENEQUIPMENT, COUNTERS, BACKSPLASH, AND FURNITURE.C. LOW-VOLTAGE CABLES MAY BE RUN OPEN AIR IN ACCESSIBLECEILING SPACES ABOVE SUSPENDED ACOUSTICAL CEILING TILEGRIDS. ROUTE CABLES IN CONDUIT THROUGH INACCESSIBLECEILING AREAS (I.E. HARD LID) AND WHERE EXPOSED TOSTRUCTURE.D. MAINTAIN 36" WORKING CLEARANCE IN FRONT OF ELECTRICALPANELS PER NEC REQUIREMENTS.E. GUEST UNIT DEVICE LAYOUTS NOT SHOWN ON THIS SHEET FORCLARITY. SEE SHEET E5.02 AND E5.03 FOR ENLARGED TYPICALGUEST UNIT DEVICE LAYOUTS. SEE ARCHITECTURAL PLANS FORQUANITIES AND LOCATIONS OF TYPICAL GUEST UNIT TYPES.F. FIRE ALARM SYSTEM DEVICE LAYOUT SHOWS OWNER'S MINIMUMREQUIREMENTS. FIRE ALARM SYSTEM TO BE DESIGNED BYCERTIFIED FIRE ALARM DESIGNER AND APPROVED BY AHJ PRIOR TOORDERING AND INSTALLATION.G. SEE ARCHITECTURAL FLOOR PLANS FOR DIMENSIONED LOCATIONSOF ALL FLOOR BOXES
W/D
W/D
DNUP53.16.12.1DC.1ECCBB8.1941.1A78610H41SDP4X-SDP4L41L42L43111ELEV. 1113ELEV. 2417ELEVATOR LOBBY409LINENS &HOUSEKEEPING140LINEN CHUTE407EFFICIENCY409APANELS406STAIR 1408EFFICIENCY405EFFICIENCY403EFFICIENCYENLARGED401KING 1-BEDROOMENLARGED402KING1-BEDROOM404KING STUDIO410DOUBLE QUEEN412DOUBLE QUEENADA-M-T414KING STUDIO416KING STUDIO418KING STUDIO400CONNECTINGCORRIDOR415GUEST CORRIDORHPSSSSSSSSSEH-41FCU-343FCU-342FCU-341SMOKE DAMPERSMOKE DAMPERL41-1,3L41-1,3L41-1,3L41-2L41-6L41-6IHL41-5L41-5L41-5L41-5L41-5L41-5L41-7L41-9L41-9L41-9L41-9L41-9401ABALCONY402ABALCONY409BIDF409CDACMAG HOLD1L41-1022MML41-9FACPSSFACPL41-123E31232 MERCHANT STREET, SUITE 208HONOLULU, HI 96813808-352-5299OWNER:HOMEWOOD SUITES by HILTON
SPOKANE VALLEY, WA
13515 E. Carlisle Avenue
Spokane Valley, WA 99216FSC PROJECT NO. 21012PERMITDOCUMENTSMay 31, 2024GL8 MirabeauPoint, LLCTMK:PID: 45101.0401 10909 E. Pierce LaneSpokane, WA 99206(509) 919-0901Revision ScheduleNumber Description Date5915 S REGAL STREETSUITE 201SPOKANE, WA 99223PH: 509.473.9218Kelly@kwrllc.comwww.kwrllc.com5/30/2024 12:52:08 PMSTATE OF WASHINGTONREGISTERED PROFESSIONAL ENG
INEER48350 KELLY A
N
DREW WATERMAN05.31.24FOURTH FLOORELECTRICAL PLAN -AREA AE-304AFLAG NOTESSCALE:1/8" = 1'-0"FOURTH FLOOR ELECTRICAL PLAN - AREA ASHEET E-304A
SHEET E-304B
SHEET E-304A
SHEET E-304B
GENERAL NOTESA. COORDINATE WITH MECHANICAL, PRIOR TO ROUGH-IN, FOR FINAL EQUIPMENT INSTALL LOCATIONS AND CONNECTION REQUIREMENTS.B. COORDINATE RECEPTACLE MOUNTING HEIGHTS IN ALL KITCHEN ANDBREAK ROOM AREAS TO AVOID CONFLICTS WITH KITCHENEQUIPMENT, COUNTERS, BACKSPLASH, AND FURNITURE.C. LOW-VOLTAGE CABLES MAY BE RUN OPEN AIR IN ACCESSIBLECEILING SPACES ABOVE SUSPENDED ACOUSTICAL CEILING TILEGRIDS. ROUTE CABLES IN CONDUIT THROUGH INACCESSIBLECEILING AREAS (I.E. HARD LID) AND WHERE EXPOSED TOSTRUCTURE.D. MAINTAIN 36" WORKING CLEARANCE IN FRONT OF ELECTRICALPANELS PER NEC REQUIREMENTS.E. GUEST UNIT DEVICE LAYOUTS NOT SHOWN ON THIS SHEET FORCLARITY. SEE SHEET E5.02 AND E5.03 FOR ENLARGED TYPICALGUEST UNIT DEVICE LAYOUTS. SEE ARCHITECTURAL PLANS FORQUANITIES AND LOCATIONS OF TYPICAL GUEST UNIT TYPES.F. FIRE ALARM SYSTEM DEVICE LAYOUT SHOWS OWNER'S MINIMUMREQUIREMENTS. FIRE ALARM SYSTEM TO BE DESIGNED BYCERTIFIED FIRE ALARM DESIGNER AND APPROVED BY AHJ PRIOR TOORDERING AND INSTALLATION.G. SEE ARCHITECTURAL FLOOR PLANS FOR DIMENSIONED LOCATIONSOF ALL FLOOR BOXESVERIFY EXACT CONNECTION LOCATIONS AND REQUIREMENTS WITHDOOR HARDWARE PROVIDER.PROVIDE 120V CONNECTIONS AND FIRE ALARM CONNECTION FORFIRE SMOKE DAMPERS IN MECHANICAL CHASE/DUCTWORK IN THISAPPROXIMATE LOCATION. SEE MECHANICAL PLANS FOR EXACTLOCATIONS.PROVIDE (3)4"C EACH INTO IDF ROOM ABOVE AND BELOW, FORCABLE ROUTING BETWEEN FLOORS.123
DNUPLL45L44415AELECTRICAL420KING STUDIO426KING STUDIO430KING STUDIO438KING STUDIOADA-M-RI419KING STUDIO421KING STUDIO423KING STUDIO425KING STUDIO427EFFICIENCY429EFFICIENCY431EFFICIENCY433EFFICIENCY437KING STUDIO435DOUBLE QUEEN432STAIR 2428EFFICIENCY434EFFICIENCY436DOUBLE QUEEN424DOUBLE QUEEN422DOUBLE QUEENSSSSSSSSEH-42FCU-345FCU-344L41-1,3L41-1,3L41-4HL41-11L41-11L41-11L41-11L41-11435ABALCONY437ABALCONY425ABALCONY423ABALCONY421ABALCONY419ABALCONY56.18.1978610FGHML.1KNPQJE32 MERCHANT STREET, SUITE 208HONOLULU, HI 96813808-352-5299OWNER:HOMEWOOD SUITES by HILTON
SPOKANE VALLEY, WA
13515 E. Carlisle Avenue
Spokane Valley, WA 99216FSC PROJECT NO. 21012PERMITDOCUMENTSMay 31, 2024GL8 MirabeauPoint, LLCTMK:PID: 45101.0401 10909 E. Pierce LaneSpokane, WA 99206(509) 919-0901Revision ScheduleNumber Description Date5915 S REGAL STREETSUITE 201SPOKANE, WA 99223PH: 509.473.9218Kelly@kwrllc.comwww.kwrllc.com5/30/2024 12:52:14 PMSTATE OF WASHINGTONREGISTERED PROFESSIONAL ENG
INEER48350 KELLY A
N
DREW WATERMAN05.31.24FOURTH FLOORELECTRICAL PLAN -AREA BE-304BSCALE:1/8" = 1'-0"FOURTH FLOOR ELECTRICAL PLAN - AREA BSHEET E-304ASHEET E-304BSHEET E-304ASHEET E-304B
GENERAL NOTESA. COORDINATE WITH MECHANICAL, PRIOR TO ROUGH-IN, FOR FINAL EQUIPMENT INSTALL LOCATIONS AND CONNECTION REQUIREMENTS.B. COORDINATE RECEPTACLE MOUNTING HEIGHTS IN ALL KITCHEN ANDBREAK ROOM AREAS TO AVOID CONFLICTS WITH KITCHENEQUIPMENT, COUNTERS, BACKSPLASH, AND FURNITURE.C. LOW-VOLTAGE CABLES MAY BE RUN OPEN AIR IN ACCESSIBLECEILING SPACES ABOVE SUSPENDED ACOUSTICAL CEILING TILEGRIDS. ROUTE CABLES IN CONDUIT THROUGH INACCESSIBLECEILING AREAS (I.E. HARD LID) AND WHERE EXPOSED TOSTRUCTURE.D. MAINTAIN 36" WORKING CLEARANCE IN FRONT OF ELECTRICALPANELS PER NEC REQUIREMENTS.E. GUEST UNIT DEVICE LAYOUTS NOT SHOWN ON THIS SHEET FORCLARITY. SEE SHEET E5.02 AND E5.03 FOR ENLARGED TYPICALGUEST UNIT DEVICE LAYOUTS. SEE ARCHITECTURAL PLANS FORQUANITIES AND LOCATIONS OF TYPICAL GUEST UNIT TYPES.F. FIRE ALARM SYSTEM DEVICE LAYOUT SHOWS OWNER'S MINIMUMREQUIREMENTS. FIRE ALARM SYSTEM TO BE DESIGNED BYCERTIFIED FIRE ALARM DESIGNER AND APPROVED BY AHJ PRIOR TOORDERING AND INSTALLATION.G. SEE ARCHITECTURAL FLOOR PLANS FOR DIMENSIONED LOCATIONSOF ALL FLOOR BOXES
W/D
W/D
DN53.16.12.1DC.1ECCBB8.1941.1A78610H5MSDP5X-SDP5L51L52L53ELEV-1ELEV-2H1Y-1H1Y-2ELEVX-ELEV111ELEV. 1113ELEV. 2517ELEVATOR LOBBY140LINEN CHUTE509APANELS506STAIR 1508EFFICIENCY505EFFICIENCY503EFFICIENCYADA-M-T501KING 1-BEDROOMENLARGED502KING1-BEDROOM504KING STUDIO510DOUBLE QUEEN512DOUBLE QUEENENLARGED514KING STUDIO516KING STUDIO518KING STUDIO500CONNECTINGCORRIDOR515GUEST CORRIDORNEMA 4XNEMA 4XHPSSSSSSSSSSS507EFFICIENCYEH-51FCU-353FCU-352FCU-351SMOKE DAMPERSMOKE DAMPERFCU-500L51-1,3L51-1,3L51-1,3L51-1,3L51-2L51-6L51-6IH33J4L51-10L51-10L51-10L51-10L51-10L51-10L51-12L51-14L51-14L51-14L51-14ELEV-3ELEV-3509LINENS &HOUSEKEEPING509BIDF509CDAC501ABALCONY502ABALCONYMAG HOLDL51-22144MML51-1455R57E31232 MERCHANT STREET, SUITE 208HONOLULU, HI 96813808-352-5299OWNER:HOMEWOOD SUITES by HILTON
SPOKANE VALLEY, WA
13515 E. Carlisle Avenue
Spokane Valley, WA 99216FSC PROJECT NO. 21012PERMITDOCUMENTSMay 31, 2024GL8 MirabeauPoint, LLCTMK:PID: 45101.0401 10909 E. Pierce LaneSpokane, WA 99206(509) 919-0901Revision ScheduleNumber Description Date5915 S REGAL STREETSUITE 201SPOKANE, WA 99223PH: 509.473.9218Kelly@kwrllc.comwww.kwrllc.com5/30/2024 12:52:18 PMSTATE OF WASHINGTONREGISTERED PROFESSIONAL ENG
INEER48350 KELLY A
N
DREW WATERMAN05.31.24FIFTH FLOORELECTRICAL PLAN -AREA AE-305AFLAG NOTESVERIFY EXACT CONNECTION LOCATIONS AND REQUIREMENTS WITHDOOR HARDWARE PROVIDER.FIELD COORDINATE EXACT CONNECTION LOCATIONS ANDREQUIREMENTS WITH ELEVATOR VENDOR. LOCATIONS SHOWNBASED ON PRELIMINARY COORDINATION.JUNCTION BOX FOR DATA CONNECTION TO ELEVATOR SYSTEM.ROUTE (1)1"C TO MDF/PBX ROOM, FOR TELEPHONE/DATA/SECURITYCONNECTIONS TO ELEVATOR EQUIPMENT.PROVIDE 120V CONNECTIONS AND FIRE ALARM CONNECTION FORFIRE SMOKE DAMPERS IN MECHANICAL CHASE/DUCTWORK IN THISAPPROXIMATE LOCATION. SEE MECHANICAL PLANS FOR EXACTLOCATIONS.COORDINATE LOCATION OF ELEVATOR SERVICE RECEPTACLE ANDCONNECTION TO ELEVATOR CONTROLLER DISCONNECT WITHELEVATOR INSTALLER PRIOR TO ROUGH-IN.PROVIDE RELAYS FOR FLOOR RECALL AND FIREMAN'S SERVICE.COORDINATE EXACT QUANTITY WITH ELEVATOR INSTALLER.PROVIDE (3)4"C INTO IDF ROOM BELOW, FOR CABLE ROUTINGBETWEEN FLOORS.1SCALE:1/8" = 1'-0"FIFTH FLOOR ELECTRICAL PLAN - AREA ASHEET E-305A
SHEET E-305B
SHEET E-305A
SHEET E-305B
GENERAL NOTESA. COORDINATE WITH MECHANICAL, PRIOR TO ROUGH-IN, FOR FINAL EQUIPMENT INSTALL LOCATIONS AND CONNECTION REQUIREMENTS.B. COORDINATE RECEPTACLE MOUNTING HEIGHTS IN ALL KITCHEN ANDBREAK ROOM AREAS TO AVOID CONFLICTS WITH KITCHENEQUIPMENT, COUNTERS, BACKSPLASH, AND FURNITURE.C. LOW-VOLTAGE CABLES MAY BE RUN OPEN AIR IN ACCESSIBLECEILING SPACES ABOVE SUSPENDED ACOUSTICAL CEILING TILEGRIDS. ROUTE CABLES IN CONDUIT THROUGH INACCESSIBLECEILING AREAS (I.E. HARD LID) AND WHERE EXPOSED TOSTRUCTURE.D. MAINTAIN 36" WORKING CLEARANCE IN FRONT OF ELECTRICALPANELS PER NEC REQUIREMENTS.E. GUEST UNIT DEVICE LAYOUTS NOT SHOWN ON THIS SHEET FORCLARITY. SEE SHEET E5.02 AND E5.03 FOR ENLARGED TYPICALGUEST UNIT DEVICE LAYOUTS. SEE ARCHITECTURAL PLANS FORQUANITIES AND LOCATIONS OF TYPICAL GUEST UNIT TYPES.F. FIRE ALARM SYSTEM DEVICE LAYOUT SHOWS OWNER'S MINIMUMREQUIREMENTS. FIRE ALARM SYSTEM TO BE DESIGNED BYCERTIFIED FIRE ALARM DESIGNER AND APPROVED BY AHJ PRIOR TOORDERING AND INSTALLATION.G. SEE ARCHITECTURAL FLOOR PLANS FOR DIMENSIONED LOCATIONSOF ALL FLOOR BOXES234567
DNLL55L54515AELECTRICAL520KING STUDIO526KING STUDIO530KING STUDIO538KING STUDIOENLARGED519KING STUDIO521KING STUDIO523KING STUDIO525KING STUDIO527EFFICIENCY529EFFICIENCY531EFFICIENCY533EFFICIENCY537KING STUDIO535DOUBLE QUEEN532STAIR 2528EFFICIENCY534EFFICIENCY536DOUBLE QUEEN524DOUBLE QUEEN522DOUBLE QUEENSSSSSSSSEH-52FCU-355FCU-354L51-1,3L51-1,3L51-4HBUILDING MOUNTED SIGNAGELCM112L51-16L51-16L51-16L51-16L51-16L51-18535ABALCONY537ABALCONY525ABALCONY523ABALCONY521ABALCONY519ABALCONY56.18.1978610FGHML.1KNPQJE32 MERCHANT STREET, SUITE 208HONOLULU, HI 96813808-352-5299OWNER:HOMEWOOD SUITES by HILTON
SPOKANE VALLEY, WA
13515 E. Carlisle Avenue
Spokane Valley, WA 99216FSC PROJECT NO. 21012PERMITDOCUMENTSMay 31, 2024GL8 MirabeauPoint, LLCTMK:PID: 45101.0401 10909 E. Pierce LaneSpokane, WA 99206(509) 919-0901Revision ScheduleNumber Description Date5915 S REGAL STREETSUITE 201SPOKANE, WA 99223PH: 509.473.9218Kelly@kwrllc.comwww.kwrllc.com5/30/2024 12:52:24 PMSTATE OF WASHINGTONREGISTERED PROFESSIONAL ENG
INEER48350 KELLY A
N
DREW WATERMAN05.31.24FIFTH FLOORELECTRICAL PLAN -AREA BE-305BFLAG NOTESPROVIDE CONTROL MODULE ABOVE ACCESSIBLE CEILING IN GUESTCORRIDOR FOR CONTROL OF BUILDING SIGNAGE CIRCUIT. MODULESHALL BE CONTROLLED VIA TIMECLOCK, INTEGRAL TO NETWORKLIGHTING CONTROL SYSTEM.PROVIDE 120V CONNECTION FOR BUILDING MOUNTED SIGNAGE. SEEARCHITECTURAL ELEVATIONS FOR EXACT HEIGHT.1SCALE:1/8" = 1'-0"FIFTH FLOOR ELECTRICAL PLAN - AREA BSHEET E-305ASHEET E-305BSHEET E-305ASHEET E-305B
GENERAL NOTESA. COORDINATE WITH MECHANICAL, PRIOR TO ROUGH-IN, FOR FINAL EQUIPMENT INSTALL LOCATIONS AND CONNECTION REQUIREMENTS.B. COORDINATE RECEPTACLE MOUNTING HEIGHTS IN ALL KITCHEN ANDBREAK ROOM AREAS TO AVOID CONFLICTS WITH KITCHENEQUIPMENT, COUNTERS, BACKSPLASH, AND FURNITURE.C. LOW-VOLTAGE CABLES MAY BE RUN OPEN AIR IN ACCESSIBLECEILING SPACES ABOVE SUSPENDED ACOUSTICAL CEILING TILEGRIDS. ROUTE CABLES IN CONDUIT THROUGH INACCESSIBLECEILING AREAS (I.E. HARD LID) AND WHERE EXPOSED TOSTRUCTURE.D. MAINTAIN 36" WORKING CLEARANCE IN FRONT OF ELECTRICALPANELS PER NEC REQUIREMENTS.E. GUEST UNIT DEVICE LAYOUTS NOT SHOWN ON THIS SHEET FORCLARITY. SEE SHEET E5.02 AND E5.03 FOR ENLARGED TYPICALGUEST UNIT DEVICE LAYOUTS. SEE ARCHITECTURAL PLANS FORQUANITIES AND LOCATIONS OF TYPICAL GUEST UNIT TYPES.F. FIRE ALARM SYSTEM DEVICE LAYOUT SHOWS OWNER'S MINIMUMREQUIREMENTS. FIRE ALARM SYSTEM TO BE DESIGNED BYCERTIFIED FIRE ALARM DESIGNER AND APPROVED BY AHJ PRIOR TOORDERING AND INSTALLATION.G. SEE ARCHITECTURAL FLOOR PLANS FOR DIMENSIONED LOCATIONSOF ALL FLOOR BOXES2
533.16.12.1DC.1LML.1ECCBB1118.1941.1AKNPQ278610HJCU-03ANEMA 3RERV-01NEMA 3RCU-04NEMA 3RCU-05CU-02ANEMA 3RCU-02BNEMA 3RCU-03BNEMA 3RNEMA 3RH5M-1,3,5H5M-7,9,11H5M-2,4,6H5M-8,10,12L51-5,7,9L51-11,13,15H5M-13,15,17WPWPWPWP1TYP
S2L51-8L51-8L51-8L51-8KE-7.2NEMA 3RL51-17,193432 MERCHANT STREET, SUITE 208HONOLULU, HI 96813808-352-5299OWNER:HOMEWOOD SUITES by HILTON
SPOKANE VALLEY, WA
13515 E. Carlisle Avenue
Spokane Valley, WA 99216FSC PROJECT NO. 21012PERMITDOCUMENTSMay 31, 2024GL8 MirabeauPoint, LLCTMK:PID: 45101.0401 10909 E. Pierce LaneSpokane, WA 99206(509) 919-0901Revision ScheduleNumber Description Date5915 S REGAL STREETSUITE 201SPOKANE, WA 99223PH: 509.473.9218Kelly@kwrllc.comwww.kwrllc.com5/30/2024 12:52:26 PMSTATE OF WASHINGTONREGISTERED PROFESSIONAL ENG
INEER48350 KELLY A
N
DREW WATERMAN05.31.24OVERALL ELECTRICALROOF PLANE-306GENERAL NOTESFLAG NOTESPROVIDE HVAC EQUIPMENT MAINTENANCE RECEPTACLE PER NEC210.63. FIELD LOCATE WITHIN 25'-0" OF ROOF MOUNTED HVACEQUIPMENT. PROVIDE STRUT MOUNTING HARDWARE AS REQUIRED.DUCT SMOKE DETECTOR LOCATION SHOWN FOR REFERENCE.COORDINATE WITH OWNER SELECTED FIRE ALARM VENDOR FORRACEWAY REQUIREMENTS.COOLER COMPRESSOR LOCATION SHOWN IS PRELIMINARY. VERIFYFINAL LOCATION WITH COOLER PACKAGE PROVIDER PRIOR TOROUGH-IN.2"C ROUTED FROM PBX TO ROOFTOP FOR FUTURE SATELLITE ISPCABLING BY OWNER SELECTED VENDOR. STUB CONDUIT UPTHROUGH ROOF AND CAP FOR FUTURE USE. LOCATION SHOWN ISAPPROXIMATE.1SCALE:3/32" = 1'-0"OVERALL ELECTRICAL ROOF PLANA. SEE ARCHITECTURAL PLANS, SECTION, AND ELEVATIONS FOR EXACTEQUIPMENT AND DEVICE LOCATIONS.B. SEE ARCHITECTURAL PLANS FOR LOCATIONS OF SOUND, SMOKE,AND FIRE RATED WALLS.C. COORDINATE WITH MECHANICAL, PRIOR TO ROUGH-IN, FOR FINALEQUIPMENT INSTALL LOCATIONS AND CONNECTION REQUIREMENTS.D. MAINTAIN 36" WORKING CLEARANCE IN FRONT OF ELECTRICALPANELS PER NEC REQUIREMENTS.234
TSC-20X18X8.62BOX123FOOD PREPFCU-216KE-22AKE-22BKE-26L14A-1,3KE-41KE-49AKE-49BKE-47KE-48KE-42AKE-42BKE-7KE-7.1NEMA 4XKE-2KE-2.1KE-2.2KE-50KE-31KE-20T2+44"+44"JHT109-WALK-IN COOLER111L1KA-1L1KA-3L1KA-5L1KA-7L1KA-9L1KA-11L1KB-1L1KB-5L1KB-2,4L1KB-8,10L1KB-14,16L1KA-2L1KA-4,6,8L1KA-10,12,14L1KA-13,15L1KA-17L1KA-19L1KB-9,117612L1KA-26H-1H-1.1L1KA-28L1KA-302338J5L1KA-37GAS SOLENOIDL1KB-15MAU-01L1KA-32,34,36L1KAL1KBMAG HOLDML14A-3120103POOL MEPAHU-01DH-01HSUH-01L11L12L1PEVL12-6L12-2,4H1M-1,3,515L12-3517L13SDP11H11H1M104ELECTRICALAHU-01DH-01HSL11L12L1PEVMSBX-SDP11ATS-YH1YT1T1GTWYL12-6H1M-1,3,5LCM1LCM11413L12-33L12-35L12-35L12-35L13T1183D2121LOBBYT2T2T2IVRCMRCMRCMSWEET SHOPSIGNAGECASEWORKLIGHTINGCONNECTIONKE-89KE-85KE-84L1KA-29L1KA-31,33L1KA-35L14A-22L14A-22L14A-24L14A-24L14A-26L14A-26L14A-30L14A-3016ICSIV19H832 MERCHANT STREET, SUITE 208HONOLULU, HI 96813808-352-5299OWNER:HOMEWOOD SUITES by HILTON
SPOKANE VALLEY, WA
13515 E. Carlisle Avenue
Spokane Valley, WA 99216FSC PROJECT NO. 21012PERMITDOCUMENTSMay 31, 2024GL8 MirabeauPoint, LLCTMK:PID: 45101.0401 10909 E. Pierce LaneSpokane, WA 99206(509) 919-0901Revision ScheduleNumber Description Date5915 S REGAL STREETSUITE 201SPOKANE, WA 99223PH: 509.473.9218Kelly@kwrllc.comwww.kwrllc.com5/30/2024 12:52:37 PMSTATE OF WASHINGTONREGISTERED PROFESSIONAL ENG
INEER48350 KELLY A
N
DREW WATERMAN05.31.24ENLARGEDELECTRICAL PLANSE-501GENERAL NOTESFLAG NOTESCIRCUITS FOR COOKING EQUIPMENT UNDER RANGE HOOD TO BEDE-ENERGIZED UPON ACTIVATION OF FIRE ALARM SYSTEM;DE-ENERGIZED VIA ANSUL SYSTEM. SEE PANEL SCHEDULES FORADDITIONAL INFORMATION.PROVIDE 3/4"C FROM ANSUL HOOD CONTROL PANEL TO PANEL FORSHUNT TRIP CONTROL WIRING.PROVIDE POWER CIRCUIT FOR ANSUL SYSTEM INDICATED ONDRAWINGS. COORDINATE ALL ADDITIONAL CONNECTIONREQUIREMENTS WITH HOOD PROVIDER PRIOR TO ROUGH IN.PROVIDE CONNECTION FROM HOOD ANSUL PANEL SUPPRESSIONSYSTEM TO BUILDING FIRE ALARM SYSTEM PER REQUIREMENTS OFNFPA 96. PROVIDE RACEWAY AND LOW VOLTAGE CONTROL WIRINGFOR HOOD ASSEMBLY PER MANUFACTURER'S SHOP DRAWINGS.PROVIDE 1/2" CONDUIT FROM HOOD CONTROL PANEL TO GASSOLENOID VALVE. PROVIDE LOW VOLTAGE CABLING FOR GAS SHUTOFF VALVE WHEN THE FIRE ALARM GOES INTO ALARM STATE.COORDINATE FINAL LOCATIONS WITH MANUFACTURER ANDMECHANICAL DRAWINGS.COORDINATE WITH KITCHEN EQUIPMENT PROVIDER AND CASEWORKPROVIDER FOR BRANCH CIRCUIT ROUTING AND ROUGH INLOCATIONS.MANUAL PULL STATION FOR ANSUL SYSTEM. PROVIDE CONNECTIONBETWEEN DEVICE AND ANSUL CONTROL PANEL AND FIRE ALARM /FIRE SUPPRESSION SYSTEM AS INDICATED ON SHOP DRAWINGS.PROVIDE RACEWAY AND LOW VOLTAGE CONTROL WIRING FORHOOD ASSEMBLY PER MANUFACTURER'S SHOP DRAWINGS.PROVIDE 120V CIRCUIT FOR HEAT TAPE IN REFRIGERATIONCONDENSATE LINE. COORDINATE WORK WITH REFRIGERATIONCONTRACTOR INSTALLING THE DRAIN LINE PRIOR TO ROUGH-IN.PROVIDE GFP PROTECTION AT CIRCUIT BREAKER PER HEAT TAPEMANUFACTURER'S INSTRUCTIONS.CONTRACTOR TO WIRE AND INSTALL LIGHT SWITCH DEVICEPROVIDED WITH COOLER PACKAGE. COORDINATE EXACT LOCATIONAND REQUIREMENTS WITH EQUIPMENT SUPPLIER.PROVIDE 'EYS' FITTINGS AND LISTED SEALING METHOD FORCONDUCTORS, RACEWAYS, OR SLEEVES ENTERING TH WALK-INCOOLER PER NEC 300.7(A). COORDINATE LOCATIONS WITH WALK-INCOOLER MANUFACTURER.CONNECTION LOCATIONS SHOWN BASED OFF OF PRELIMINARYKITCHEN LAYOUT PROVIDED BY OWNER SELECTED VENDOR.COORDINATE ALL EQUIPMENT LOCATIONS, CONNECTIONREQUIREMENTS, ROUGH-IN HEIGHTS, COOLER SEALINGREQUIREMENTS, ETC WITH KITCHEN EQUIPMENT PROVIDER PRIORTO ROUGH-IN.CONTROL MODULES FOR (2) SITE SIGNAGE BRANCH CIRCUITS, L12-15AND L12-19. ROUTE BRANCH CIRCUITS THROUGH CONTROLMODULES FOR TIMECLOCK CONTROL VIA NETWORK LIGHTINGCONTROL SYSTEM.WALL SPACE RESERVED FOR FUTURE EV CHARGING BRANCHPANELS PER WAC 429.5, AND SOLAR INVERTER, COMBINER, ANDDISCONNECTING EQUIPMENT BY OWNER SELECTED SOLARINSTALLER.POOL EQUIPMENT AND ASSOCIATED BRANCH CIRCUITING IN THISWILL BE ADDED AS PART OF A DEFERRED SUBMITTAL. PANEL L1PINTENDED AS BRANCH PANELBOARD DEDICATED TO POOLEQUIPMENT.PROVIDE 120V CIRCUIT TO SWEET SHOP SIGNAGE MOUNTED TOFRONT OF SOFFIT ABOVE.UTILIZE LIQUIDTIGHT METALLIC FLEXIBLE CONDUIT, ANDNON-CORROSIVE FITTINGS/BOXES/DEVICES IN THIS SPACE.PROVIDE 4" HIGH, 4" OFFSET HOUSE-KEEPING PAD FOR ELECTRICALEQUIPMENT INDICATED. COORDINATE FINAL REQUIREMENTS WITHSTRUCTURAL.COORDINATE CONNECTIONS AND MOUNTING LOCATIONS WITHCASEWORK PROVIDER.VERIFY EXACT CONNECTION LOCATIONS AND REQUIREMENTS WITHDOOR HARDWARE PROVIDER.1A. COORDINATE WITH MECHANICAL, PRIOR TO ROUGH-IN, FOR FINAL EQUIPMENT INSTALL LOCATIONS AND CONNECTION REQUIREMENTS.B. COORDINATE RECEPTACLE MOUNTING HEIGHTS IN ALL KITCHEN ANDBREAK ROOM AREAS TO AVOID CONFLICTS WITH KITCHENEQUIPMENT, COUNTERS, BACKSPLASH, AND FURNITURE.C. LOW-VOLTAGE CABLES MAY BE RUN OPEN AIR IN ACCESSIBLECEILING SPACES ABOVE SUSPENDED ACOUSTICAL CEILING TILEGRIDS. ROUTE CABLES IN CONDUIT THROUGH INACCESSIBLECEILING AREAS (I.E. HARD LID) AND WHERE EXPOSED TOSTRUCTURE.D. MAINTAIN 36" WORKING CLEARANCE IN FRONT OF ELECTRICALPANELS PER NEC REQUIREMENTS.E. FIRE ALARM SYSTEM DEVICE LAYOUT SHOWS OWNER'S MINIMUMREQUIREMENTS. FIRE ALARM SYSTEM TO BE DESIGNED BYCERTIFIED FIRE ALARM DESIGNER AND APPROVED BY AHJ PRIOR TOORDERING AND INSTALLATION.F. REFER TO ARCHITECTURAL PLANS FOR DEVICE MOUNTING HEIGHTSAND DIMENSIONED LOCATIONS.G. COORDINATE ALL CONNECTION MOUNTING HEIGHTS ANDREQUIREMENTS WITH KITCHEN VENDOR PRIOR TO ROUGH-IN.SCALE:1POOL MEP AND MAIN ELECTRICAL ROOM ELECTRICAL PLAN1/4" = 1'-0"SCALE:2FOOD PREP ROOM ELECTRICAL PLAN1/4" = 1'-0"23456789101112131415SCALE:3ENLARGED RECEPTION AND SWEET SHOP ELECTRICAL PLAN1/4" = 1'-0"1617181920
T1GTVWAPWAPJREFDWUSBGDMW/HOODCOOK-2G.B06G.B06G.B06G.B06G.Z24G.B06M1423VANITY LIT MIRRORAPTAC-01A-6A-6A-6A-6A-6A-6A-6A-1,3A-5,7A-2A-2A-9A-4A-8A-8A-8A-8A-8A-8A-8A-105S/C55G.Z24A-6dbcaaabaacddGTVWAPT11M4REFCOOK-2DWMW/HOODGDJ2G.P01G.P01G.B06G.B06G.B06G.B06G.B06G.B06USB3VANITY LIT MIRRORBPTAC-01B-1,3B-5,7B-9B-2B-2B-4B-6B-6B-6 B-6B-6B-6B-6B-6B-6B-8B-8B-8B-8B-8B-8B-105S/C5G.Z24G.Z24B-6B-6aedcacebebaaaadbREFCOOK-2DWMWGDM14HOOD3VANITY LIT MIRRORG.B06G.B06G.B06GTVWAPT1USBG.B06G.B06G.B06G.Z24J2CPTAC-01C-1,3C-11C-5,7C-9C-2C-2C-4C-6C-6C-6C-6C-6C-6C-6C-6C-8C-8C-8C-8C-8C-8C-8C-1055S/CG.Z24C-6acbaaaaabbbcGTVWAPT11REFCOOK-2DWMWGDJ2G.P01G.P01G.B06G.B06G.B06USB3M4HOODG.B06G.B06G.B06VANITY LIT MIRRORDPTAC-01D-1,3D-5,7D-9D-11D-2D-2D-4D-6D-6D-6D-6D-6D-6D-6D-6D-6D-8D-8D-8D-8D-8D-8D-8D-105S/C5G.Z24G.Z24D-6D-6aaacbdcdccabaabG.W01WPB-9B-6732 MERCHANT STREET, SUITE 208HONOLULU, HI 96813808-352-5299OWNER:HOMEWOOD SUITES by HILTON
SPOKANE VALLEY, WA
13515 E. Carlisle Avenue
Spokane Valley, WA 99216FSC PROJECT NO. 21012PERMITDOCUMENTSMay 31, 2024GL8 MirabeauPoint, LLCTMK:PID: 45101.0401 10909 E. Pierce LaneSpokane, WA 99206(509) 919-0901Revision ScheduleNumber Description Date5915 S REGAL STREETSUITE 201SPOKANE, WA 99223PH: 509.473.9218Kelly@kwrllc.comwww.kwrllc.com5/30/2024 12:52:43 PMSTATE OF WASHINGTONREGISTERED PROFESSIONAL ENG
INEER48350 KELLY A
N
DREW WATERMAN05.31.24ENLARGEDELECTRICAL PLANSE-502GENERAL NOTESFLAG NOTESDOORBELL AND DOORBELL CONTROL SWITCH IN COMMUNICATIONFEATURE ROOMS ONLY. SEE ARCHITECTURAL PLANS FORCOMMUNICATION FEATURE ROOM LOCATIONS.THERMOSTAT LOCATION (THERMOSTAT BY OTHERS). PROVIDECONDUIT PATHWAY FROM VTAC TO THERMOSTAT AS REQUIRED.COORDINATE WITH MECHANICAL FOR EXACT REQUIREMENTS.PROVIDE 120V CONNECTION FOR INTERNALLY LIT VANITY MIRROR.COORDINATE WITH FIXTURE PROVIDER FOR ROUGH-INREQUIREMENTS. LIT MIRROR PROVIDED AS PART OF FURNITUREPACKAGE, SHALL BE INSTALLED BY ELECTRICAL CONTRACTOR.MASTER CONTROL SWITCH FOR CONTROL OF ALL PERMANENTLYINSTALLED LIGHT FIXTURES AND SWITCHED RECEPTACLES WITHINGUEST UNIT (AS REQUIRED BY WSEC 405.2.5). SEE LIGHTINGCONTROL DEVICE SCHEDULE FOR ADDITIONAL INFORMATION.FIRE HORN IN STANDARD ROOMS; PROVIDE FIRE HORN/STROBE INCOMMUNICATION FEATURE ROOMS. SEE ARCHITECTURAL PLANSFOR FEATURE ROOM LOCATIONS.1A. PROVIDE ALL HARDWARE AND ACCESSORIES REQUIRED TO MOUNTLUMINAIRE IN LOCATIONS SHOWN INCLUDING ALL MOUNTINGBRACKETS, T-BAR HANGERS, CANOPIES, ETC.B. COORDINATE WITH MECHANICAL, PRIOR TO ROUGH-IN, FOR FINALEQUIPMENT INSTALL LOCATIONS AND CONNECTION REQUIREMENTS.C. LOW-VOLTAGE CABLES MAY BE RUN OPEN AIR IN ACCESSIBLECEILING SPACES ABOVE SUSPENDED ACOUSTICAL CEILING TILEGRIDS. ROUTE CABLES IN CONDUIT THROUGH INACCESSIBLECEILING AREAS (I.E. HARD LID) AND WHERE EXPOSED TOSTRUCTURE.D. REFER TO ARCHITECTURAL PLANS FOR DEVICE MOUNTING HEIGHTSAND DIMENSIONED LOCATIONS.E. ALL RECEPTACLES IN GUEST UNITS SHALL BE TAMPER-RESISTANTTYPE.F. FIRE ALARM SYSTEM DEVICE LAYOUT SHOWS OWNER'S MINIMUMREQUIREMENTS. FIRE ALARM SYSTEM TO BE DESIGNED BYCERTIFIED FIRE ALARM DESIGNER AND APPROVED BY AHJ PRIOR TOORDERING AND INSTALLATION.G. ALL 120V, SINGLE PHASE, 20AMP BRANCH CIRCUITS SUPPLYINGOUTLETS OR DEVICES IN GUEST UNITS SHALL BE PROTECTED BY ANARC-FAULT CIRCUIT INTERRUPTER (AFCI) CIRCUIT BREAKER. SEEPANEL SCHEDULES FOR ADDITIONAL INFORMATION.H. GUEST UNIT LIGHTING CONTROLS ARE A MIX OF NETWORKEDCONTROLS INTEGRATED WITH HILTON CONNECTED ROOMS, ASWELL AS STANDALONE LINE VOLTAGE ROCKER SWITCHES. BASIS OFDESIGN AS FOLLOWS: MASTER SWITCH, AND SWITCHESCONTROLLING OVERHEAD LIGHTS AND UNDERCAB LIGHTS, AREOWNER FURNISHED, CONTRACTOR INSTALLED. SWITCHESCONTROLLING LIT VANITIES, AND PATIO SCONCES, ARE INTENDEDTO BE STANDALONE ROCKER SWITCHES, FURNISHED ANDINSTALLED BY CONTRACTOR. FOR CIRCUITING, MASTER SWITCHSHALL BE WIRED 'UPSTREAM' OF ALL OTHER SWITCHES. ALL OTHERSWITCHES SHALL BE CIRCUITED DIRECTLY 'DOWNSTREAM' OFMASTER SWITCH (I.E., NO OTHER SWITCHES CIRCUITED 'IN SERIES').VERIFY FINAL DESIGN AND PROCUREMENT INTENT WITH OWNERAND CONNECTED CONTROLS VENDOR PRIOR TO ROUGH-IN ANDORDERING OF CONTROL.SCALE:1ENLARGED ELECTRICAL PLAN - EFFICIENCY SUITE1/4" = 1'-0"SCALE:2ENLARGED ELECTRICAL PLAN - KING STUDIO1/4" = 1'-0"SCALE:4ENLARGED ELECTRICAL PLAN - ACCESSIBLE EFFICIENCY SUITE1/4" = 1'-0"SCALE:5ENLARGED ELECTRICAL PLAN - ACCESSIBLE KING STUDIO1/4" = 1'-0"2345SCALE:3ENLARGED ELECTRICAL PLAN - KING STUDIO BALCONY1/4" = 1'-0"
ALIGNGTVWAPUSBT1J31M4G.P01G.P01REFCOOK-2DWMW/HOODGDG.B06G.B06G.B06G.B06G.B06G.B06VANITY LIT MIRRORFPTAC-01F-1,3F-5,7F-9F-2F-2F-4F-6F-6F-6F-6F-6F-6F-6F-6F-8F-8F-8F-8F-8F-8F-8F-8F-10F-6255G.Z24G.Z24F-6F-6S/CabaaabbaadcdeceeVANITY LIT MIRRORG.B06G.B06G.B06MOTORIZED SHADESMREFCOOK-2DWMWGDHOODT1USBGTVWAPJG.P01G.P01G.B06G.B06G.B06HPTAC-01H-1,3H-5,7H-9H-11H-2H-2H-4H-6H-6H-6H-6H-6H-6H-6 H-6H-6H-8H-8H-8H-8H-12H-12H-12H-12H-8H-8H-10S/C3412556G.Z24G.Z24H-6H-6dcdbaaaacccbbaaW/D GR-901GR-902GR-900G.P01G.P01G.B06G.B06G.B06G.B06G.B06G.B06G.F01J2GTVT1WAPVANITY LIT MIRROR14REFCOOK-4DWMW/HOODGDWASHDRYMOTORIZED SHADESGTVWAPUSBG.B06EPTAC-01PTAC-01E-1,3E-5,7E-9E-2E-2E-4E-6E-6E-6E-6E-6E-6E-6E-6E-6E-6E-6E-8E-8E-8E-8E-15E-15E-15E-10E-11,13E-12,14E-16E-15S/CSS/C5G.Z24G.Z24E-6E-6G.B06E-6M6535aaaggbbbbbccbcdefffdeG.W01WPE-15E-67W DG.F01WASHDRYREFCOOK-4DWMWGDG.P01G.B06G.B06G.B06J2T1GTVWAP3VANITY LIT MIRRORM14MOTORIZED SHADES6MOTORIZED SHADES6HOODG.B06G.B06G.B06GTVWAPUSBGPTAC-01PTAC-01G-1,3G-5,7G-9G-11G-2G-2G-4G-6G-6G-6G-6G-6G-6G-6G-6G-6G-17G-8G-8G-8G-17G-17G-17G-8G-8G-8G-17G-10G-13,15G-12,14G-165S55S/CS/CG.P01G.Z24G.Z24G-6G-6G-6G.B06G.B06G-6G-6edeaaadddbbbbbbcc cffG.W01WPG-17G-67G.W01WPF-11F-6732 MERCHANT STREET, SUITE 208HONOLULU, HI 96813808-352-5299OWNER:HOMEWOOD SUITES by HILTON
SPOKANE VALLEY, WA
13515 E. Carlisle Avenue
Spokane Valley, WA 99216FSC PROJECT NO. 21012PERMITDOCUMENTSMay 31, 2024GL8 MirabeauPoint, LLCTMK:PID: 45101.0401 10909 E. Pierce LaneSpokane, WA 99206(509) 919-0901Revision ScheduleNumber Description Date5915 S REGAL STREETSUITE 201SPOKANE, WA 99223PH: 509.473.9218Kelly@kwrllc.comwww.kwrllc.com5/30/2024 12:52:48 PMSTATE OF WASHINGTONREGISTERED PROFESSIONAL ENG
INEER48350 KELLY A
N
DREW WATERMAN05.31.24ENLARGEDELECTRICAL PLANSE-503FLAG NOTESSCALE:2ENLARGED ELECTRICAL PLAN - DOUBLE QUEEN STUDIO1/4" = 1'-0"SCALE:5ENLARGED ELECTRICAL PLAN - ACCESSIBLE DOUBLE QUEEN STUDIO1/4" = 1'-0"SCALE:1ENLARGED ELECTRICAL PLAN - KING 1-BEDROOM1/4" = 1'-0"SCALE:4ENLARGED ELECTRICAL PLAN - ACCESSIBLE KING 1-BEDROOM1/4" = 1'-0"DOORBELL AND DOORBELL CONTROL SWITCH IN COMMUNICATIONFEATURE ROOMS ONLY. SEE ARCHITECTURAL PLANS FORCOMMUNICATION FEATURE ROOM LOCATIONS.THERMOSTAT LOCATION (THERMOSTAT BY OTHERS). PROVIDECONDUIT PATHWAY FROM VTAC TO THERMOSTAT AS REQUIRED.COORDINATE WITH MECHANICAL FOR EXACT REQUIREMENTS.PROVIDE 120V CONNECTION FOR INTERNALLY LIT VANITY MIRROR.COORDINATE WITH FIXTURE PROVIDER FOR ROUGH-INREQUIREMENTS. LIT MIRROR PROVIDED AS PART OF FURNITUREPACKAGE, SHALL BE INSTALLED BY ELECTRICAL CONTRACTOR.MASTER CONTROL SWITCH FOR CONTROL OF ALL PERMANENTLYINSTALLED LIGHT FIXTURES AND SWITCHED RECEPTACLES WITHINGUEST UNIT (AS REQUIRED BY WSEC 405.2.5). SEE LIGHTINGCONTROL DEVICE SCHEDULE FOR ADDITIONAL INFORMATION.FIRE HORN IN STANDARD ROOMS; PROVIDE FIRE HORN/STROBE INCOMMUNICATION FEATURE ROOMS. SEE ARCHITECTURAL PLANSFOR FEATURE ROOM LOCATIONS.PROVIDE MOTORIZED SHADE POWER CONNECTION AND PATHWAYTO CONTROL STATION. COORDINATE WITH EQUIPMENT PROVIDERFOR ROUGH-IN REQUIREMENTS.BALCONY DEVICES SHALL BE INSTALLED ON UNITS WITH BALCONIESWHERE SHOWN ON OVERALL FLOOR PLANS. SEE ARCHITECTURALROOM SUMMARIES FOR UNITS WITH BALCONIES.123456SCALE:3ENLARGED ELECTRICAL PLAN - DOUBLE QUEEN BALCONY1/4" = 1'-0"7GENERAL NOTESA. PROVIDE ALL HARDWARE AND ACCESSORIES REQUIRED TO MOUNTLUMINAIRE IN LOCATIONS SHOWN INCLUDING ALL MOUNTINGBRACKETS, T-BAR HANGERS, CANOPIES, ETC.B. COORDINATE WITH MECHANICAL, PRIOR TO ROUGH-IN, FOR FINALEQUIPMENT INSTALL LOCATIONS AND CONNECTION REQUIREMENTS.C. LOW-VOLTAGE CABLES MAY BE RUN OPEN AIR IN ACCESSIBLECEILING SPACES ABOVE SUSPENDED ACOUSTICAL CEILING TILEGRIDS. ROUTE CABLES IN CONDUIT THROUGH INACCESSIBLECEILING AREAS (I.E. HARD LID) AND WHERE EXPOSED TOSTRUCTURE.D. REFER TO ARCHITECTURAL PLANS FOR DEVICE MOUNTING HEIGHTSAND DIMENSIONED LOCATIONS.E. ALL RECEPTACLES IN GUEST UNITS SHALL BE TAMPER-RESISTANTTYPE.F. FIRE ALARM SYSTEM DEVICE LAYOUT SHOWS OWNER'S MINIMUMREQUIREMENTS. FIRE ALARM SYSTEM TO BE DESIGNED BYCERTIFIED FIRE ALARM DESIGNER AND APPROVED BY AHJ PRIOR TOORDERING AND INSTALLATION.G. ALL 120V, SINGLE PHASE, 20AMP BRANCH CIRCUITS SUPPLYINGOUTLETS OR DEVICES IN GUEST UNITS SHALL BE PROTECTED BY ANARC-FAULT CIRCUIT INTERRUPTER (AFCI) CIRCUIT BREAKER. SEEPANEL SCHEDULES FOR ADDITIONAL INFORMATION.H. GUEST UNIT LIGHTING CONTROLS ARE A MIX OF NETWORKEDCONTROLS INTEGRATED WITH HILTON CONNECTED ROOMS, ASWELL AS STANDALONE LINE VOLTAGE ROCKER SWITCHES. BASIS OFDESIGN AS FOLLOWS: MASTER SWITCH, AND SWITCHESCONTROLLING OVERHEAD LIGHTS AND UNDERCAB LIGHTS, AREOWNER FURNISHED, CONTRACTOR INSTALLED. SWITCHESCONTROLLING LIT VANITIES, AND PATIO SCONCES, ARE INTENDEDTO BE STANDALONE ROCKER SWITCHES, FURNISHED ANDINSTALLED BY CONTRACTOR. FOR CIRCUITING, MASTER SWITCHSHALL BE WIRED 'UPSTREAM' OF ALL OTHER SWITCHES. ALL OTHERSWITCHES SHALL BE CIRCUITED DIRECTLY 'DOWNSTREAM' OFMASTER SWITCH (I.E., NO OTHER SWITCHES CIRCUITED 'IN SERIES').VERIFY FINAL DESIGN AND PROCUREMENT INTENT WITH OWNERAND CONNECTED CONTROLS VENDOR PRIOR TO ROUGH-IN ANDORDERING OF CONTROL.
DN2104ELECTRICAL101POOL/SPLASHPAD102POOL RESTROOM103POOL MEP27.633.6 34.5 29.9 23.135.4 44.8 46.5 39.3 29.241.453.254.445.0 33.436.7 41.6 47.0 51.3 56.9 55.9 46.4 34.744.749.8 48.8 52.0 57.0 55.8 45.9 34.038.6 43.944.147.351.750.441.430.927.7 33.5 35.5 38.0 40.5 39.2 32.9 25.324.9 31.2 32.6 31.5 25.038.3 49.0 49.4 49.5 38.738.4 48.9 49.0 49.9 38.324.7 30.9 18.322.521.7 23.3 25.3 27.0 28.5 30.1 31.5 32.5 32.7 32.1 30.0 26.525.8 27.7 29.6 31.1 32.5 33.9 35.2 36.1 36.5 36.1 34.7 31.730.0 31.9 33.8 34.7 35.5 36.4 37.2 37.9 38.5 38.5 38.1 37.0 34.4 31.0 26.134.6 36.6 38.0 38.0 37.7 37.6 37.8 38.5 39.3 40.0 40.7 41.0 40.7 38.9 38.341.440.6 39.6 36.9 33.0 28.638.7 40.7 41.6 41.0 39.8 38.8 38.3 38.6 39.3 40.6 42.1 43.4 44.244.4 44.544.143.6 41.8 38.4 34.7 30.042.3 44.044.743.4 41.2 39.4 38.4 38.3 39.0 40.8 42.9 45.0 46.6 47.6 48.2 48.5 48.0 46.2 42.7 37.1 32.741.3 46.2 46.544.541.739.3 37.9 37.7 38.7 40.7 43.4 45.9 48.0 49.5 50.3 50.6 50.2 48.6 45.3 39.7 34.637.9 43.947.447.144.9 41.9 39.3 37.6 37.3 38.3 40.5 43.4 46.2 48.6 50.3 51.2 51.6 51.3 49.9 47.3 42.6 38.843.1 46.3 48.4 47.8 45.2 42.0 39.2 37.4 36.9 38.0 40.4 43.3 46.3 48.8 50.651.552.051.750.4 48.2 45.0 42.3 39.0 36.8 36.1 36.5 36.8 36.3 34.9 31.245.147.8 49.6 48.545.542.1 39.2 37.2 36.7 37.9 40.3 43.4 46.6 49.2 50.9 51.9 52.3 51.9 50.7 48.6 45.9 43.7 41.3 40.0 39.8 40.1 40.3 40.1 38.0 36.446.5 49.0 50.5 49.1 46.0 42.3 39.2 37.2 36.9 38.0 40.3 43.6 46.9 49.6 51.3 52.3 52.6 52.2 51.0 48.9 46.3 44.2 42.8 42.4 42.6 43.2 44.0 43.7 42.1 39.847.449.8 51.2 49.8 46.5 42.5 39.3 37.4 37.1 38.2 40.7 44.0 47.3 50.0 51.8 52.7 53.0 52.6 51.2 49.0 46.4 44.2 42.9 42.8 43.4 44.6 45.9 46.5 45.0 42.447.6 50.051.449.9 46.6 42.6 39.3 37.5 37.1 38.3 41.044.4 47.750.4 52.0 52.9 53.2 52.7 51.3 49.1 46.544.142.8 42.7 43.6 45.2 46.947.746.3 43.847.149.5 51.0 49.6 46.4 42.6 39.4 37.5 37.2 38.5 41.3 44.6 47.9 50.5 52.2 52.9 53.1 52.651.148.9 46.3 44.0 42.6 42.4 43.345.146.8 47.8 46.5 44.346.2 48.7 50.3 49.0 45.9 42.3 39.4 37.6 37.5 39.0 41.644.748.0 50.7 52.2 52.9 53.1 52.4 50.9 48.7 46.2 43.8 42.3 42.1 42.9 44.6 46.3 47.2 46.144.145.147.549.1 48.045.1 41.739.0 37.6 37.7 39.2 41.945.148.4 50.9 52.4 53.1 53.2 52.4 51.0 48.7 46.2 43.6 42.1 41.8 42.4 43.945.546.445.143.243.2 45.6 47.3 46.5 44.0 41.0 38.6 37.5 37.6 39.3 42.3 45.6 48.851.152.4 53.0 52.9 52.2 50.8 48.6 45.9 43.5 41.941.441.8 43.044.445.143.7 41.940.5 42.944.744.2 42.2 39.6 37.6 36.8 37.2 39.0 42.145.548.6 50.8 51.8 52.1 52.0 51.2 49.8 47.8 45.2 43.041.540.7 40.941.742.6 43.1 41.6 39.837.2 39.541.441.2 39.6 37.6 36.1 35.5 36.3 38.2 41.244.447.3 49.2 50.0 50.2 50.0 49.2 47.8 46.1 43.9 41.9 40.4 39.5 39.4 39.7 40.2 40.3 38.6 37.032.8 35.0 36.9 36.9 35.8 34.5 33.5 33.3 34.1 36.0 38.741.744.3 45.8 46.4 46.4 46.1 45.3 44.2 42.7 40.9 39.2 37.9 37.1 36.8 36.7 36.8 36.3 34.4 33.328.4 30.2 32.0 32.4 31.7 30.8 30.1 30.1 30.9 32.7 35.1 37.7 39.8 41.041.5 41.441.0 40.4 39.5 38.3 36.8 35.4 34.3 33.6 33.2 32.8 32.6 31.8 30.3 29.6Calculation SummaryLabelUnitsAvgMaxMinAvg/MinMax/MinMEP_WorkplaneFc41.5057.023.11.802.47POOL_FloorFc43.7858.824.11.822.44RR_WorkplaneFc36.3749.918.31.992.73POOL1_SURFACEFc43.7252.136.41.201.43POOL2_SURFACEFc45.1849.939.21.151.2732 MERCHANT STREET, SUITE 208HONOLULU, HI 96813808-352-5299OWNER:HOMEWOOD SUITES by HILTON
SPOKANE VALLEY, WA
13515 E. Carlisle Avenue
Spokane Valley, WA 99216FSC PROJECT NO. 21012PERMITDOCUMENTSMay 31, 2024GL8 MirabeauPoint, LLCTMK:PID: 45101.0401 10909 E. Pierce LaneSpokane, WA 99206(509) 919-0901Revision ScheduleNumber Description Date5915 S REGAL STREETSUITE 201SPOKANE, WA 99223PH: 509.473.9218Kelly@kwrllc.comwww.kwrllc.com5/30/2024 12:52:55 PMSTATE OF WASHINGTONREGISTERED PROFESSIONAL ENG
INEER48350 KELLY A
N
DREW WATERMAN05.31.24ENLARGED POOLPHOTOMETRIC PLANE-504GENERAL NOTESSCALE:1ENLARGED POOL PHOTOMETRIC PLAN1/4" = 1'-0"A. PHOTOMETRIC PLANS ARE NOT FOR CONSTRUCTION, AND INCLUDEDFOR REVIEW PURPOSES AND REFERENCE ONLY.B. LIGHTING CALCULATIONS PERFORMED IN THE CURRENT VERSIONOF LIGHTING ANALYSTS AGI32 SOFTWARE, LICENSED FOR USE BYKWR, LLC.C. CALCULATION POINTS ARE LAID OUT IN A 2'X2' GRID AT FINISHEDFLOOR LEVEL. CALCULATION UNITS ARE IN FOOT-CANDLES (FC).
DISTRIBUTION PANEL 'SDP12'208Y/120V 3P 4W22,000 AIC600A BUS
600/3LSITO EXISTINGPRIMARYJUNCTIONENCLOSUREFIRST FLOOR FIRST FLOOR
SECOND FLOOR SECOND FLOORMSERVICE POINTMAIN SWITCHBOARD 'MSB'480Y/277V 3P 4W42,000 AICSERVICE ENTRANCE RATED2500A BUS 2000/3LSIGSUSENEW UTILITY TRANSFORMER480Y/277V 3P 4W SECONDARYXFMR 'X-SDP11'300KVAP: 480V 3P 3W DELTAS: 208Y/120V 3P 4W WYEDISTRIBUTION PANEL 'SDP11'208Y/120V 3P 4W42,000 AIC800A BUS
800/3LSI400/3(2)2"C, 3#250KCMIL(AL), #3GLSI300/33"C, 3#500KCMIL(AL), #2GXFMR 'X-SDP12'225KVAP: 480V 3P 3W DELTAS: 208Y/120V 3P 4W WYE200A, 208Y/120V 3P 4WPANEL 'L11'200A, 208Y/120V 3P 4WPANEL 'L12'200A, 208Y/120V 3P 4WPANEL 'L13'225A, 208Y/120V 3P 4WPANEL 'L1P'100A, 208Y/120V 3P 4WPANEL 'LPAT'600A, 208Y/120V 3P 4WPANEL 'EV'200A, 208Y/120V 3P 4WPANEL 'L14A'200A, 208Y/120V 3P 4WPANEL 'L14B'400A, 208Y/120V 3P 4WPANEL 'L1KA'400A, 208Y/120V 3P 4WPANEL 'L1KB'200/32-1/2"C, 4#250KCMIL(AL), #6G200/32-1/2"C, 4#250KCMIL(AL), #6G200/32-1/2"C, 4#250KCMIL(AL), #6G225/33"C, 4#300KCMIL(AL), #4G100/31-1/2"C, 4#1, #6G600/3(2)3-1/2"C, 4#500KCMIL(AL), #1GLSI200/32-1/2"C, 4#250KCMIL(AL), #6G400/3(2)2-1/2"C, 4#250KCMIL(AL), #3GLSI100A, 480Y/277V 3P 4WPANEL 'H11'100A, 480Y/277V 3P 4WPANEL 'H12'200A, 480Y/277V 3P 4WPANEL 'H1M'100/31-1/2"C, 4#1, #6G100/31-1/2"C, 4#1, #6G200/32-1/2"C, 4#250KCMIL(AL), #6GXFMR 'X-SDP2'225KVAP: 480V 3P 3W DELTAS: 208Y/120V 3P 4W WYEGFP100/31-1/2"C, 4#1, #6G400/3(2)3"C, 4#350KCMIL(AL), #2GLSI300/3(2)3"C, 3#250KCMIL(AL), #3GLSI300/3(2)3"C, 3#250KCMIL(AL), #3GLSI300/3(2)3"C, 3#250KCMIL(AL), #3GLSIDISTRIBUTION PANEL 'SDP2'208Y/120V 3P 4W42,000 AIC600A BUS
600/3LSI(2)4"C, 4#500KCMIL(AL),#2/0G100A, 208Y/120V 3P 4WPANEL 'L21'TO TRANSFORMER'X-SDP3'TO TRANSFORMER'X-SDP4'TO TRANSFORMER'X-SDP5'TO PANEL 'H41'TO PANEL 'H5M'TO ELEVATOR'ELEV-1'100/31-1/2"C, 4#1, #6GDISTRIBUTION PANEL 'H1Y'480Y/277V 3P 4W22,000 AIC150A BUS GENERATOR 'GEN-Y'LEGALLY REQUIRED STANDBY (NEC 701)480Y/277V 3P 4W100KW,125KVAAUTOMATIC TRANSFERSWITCH 'ATS-Y'480Y/277V 3P 4W150A, 4-POLEBYPASS-ISOLATIONCONTACTORSTO ELEVATOR'ELEV-2'(3)4"C, 4#400KCMIL(AL), #3/0G(2)4"C, 4#500KCMIL(AL), #2/0G2"C, 4#3/0(AL), #6G1"C & CONTROL CABLE TO ATSGENERATORANNUNCIATOR1"C TO ANNUNCIATOR:CABLING PERMANUFACTUREREPOCONTROLS2"C, 4#3/0(AL), #6G150A FRAME150A FUSEMMMMMMMMMMMM300/3(2)3"C, 3#250KCMIL(AL), #3GLSITO TRANSFORMER'X-ELEV'1423765910111213#3/013#3/013#2/0141460/3SPD1560/3SPD1560/3SPD1560/3SPD1560/3SPD15MM30/33/4"C, 3#10, #10G1430/33/4"C, 4#8, #8G150/32"C, 4#3/0(AL), #6G30/33/4"C, 4#8, #8G200/3200/3200/3TO PANEL 'L23', SUBFEEDING(6) 100A PANELS AND (1) 125APANELTO PANEL 'L24', SUBFEEDING(8) 100A PANELSTO PANEL 'L25', SUBFEEDING(7) 100A PANELS2-1/2"C, 4#250KCMIL(AL), #6GPANEL 'L22'208Y/120V 3P 4W200A,200/32-1/2"C, 4#250KCMIL(AL), #6G125A, 208/120V 2P 3WGUEST UNIT 202 PANEL100A, 208/120V 2P 3WGUEST UNIT 204 PANEL125/23#1/0, #6G100/23#2, #8G16PANEL 'L16'208Y/120V 3P 4W200A,16200/32-1/2"C, 4#250KCMIL(AL), #6G100A, 208/120V 2P 3WGUEST UNIT 129 PANEL100/23#2, #8G60A, 208Y/120V 3P 4WPANEL 'LSS'60/360/31-1/4"C, 4#4, #8G17181860/3TO SOLAR INVERTEREQUIPMENT(BY SOLAR VENDOR)SYSTEM CAPACITY:153.64KW200/34E-7014E-7013"C, 4#350KCMIL(AL), #4G3"C, 4#350KCMIL(AL), #4G5E-701(6)4"C, 4#600KCMIL(AL)1916TYP(3)2"CFAULT CURRENTSCHEDULEDEVICEFAULT AIC RATING FED FROMDEVICEMSB21,54642,000UTILITYTRANSFORMERATS-Y18,50635,000 MSB / GEN-YH1Y17,05322,000ATS-YELEV1,76410,000X-ELEVH1118,79042,000MSBH127,03810,000MSBH1M19,76942,000MSBH4110,72222,000MSBH5M16,99322,000MSBSDP1121,97542,000X-SDP11EV20,11442,000SDP11L1119,51542,000SDP11L1219,09642,000SDP11L1318,26942,000SDP11L1P18,18722,000SDP11LPAT4,62010,000SDP11LSS1,25810,000SDP11SDP1213,79722,000X-SDP12L14A12,33622,000SDP12L14B11,29622,000L14AL168,93110,000SDP12L1KA11,23022,000SDP12L1KB10,66322,000L1KASDP216,87742,000X-SDP2L2112,99322,000SDP2L2213,85422,000SDP2FAULT CURRENTSCHEDULE (CONT.)DEVICEFAULT AIC RATING FED FROMDEVICEL2313,61422,000SDP2L246,71410,000SDP2L256,67310,000SDP2SDP316,68842,000X-SDP3L3112,85222,000SDP3L3213,73722,000SDP3L3313,51922,000SDP3L346,68810,000SDP3L356,64710,000SDP3SDP416,52042,000X-SDP4L4112,69922,000SDP4L4213,56522,000SDP4L4313,33222,000SDP4L446,65910,000SDP4L456,61810,000SDP4SDP516,46742,000X-SDP5L5112,69522,000SDP5L5213,51522,000SDP5L5313,28322,000SDP5L546,64410,000SDP5L556,60410,000SDP532 MERCHANT STREET, SUITE 208HONOLULU, HI 96813808-352-5299OWNER:HOMEWOOD SUITES by HILTON
SPOKANE VALLEY, WA
13515 E. Carlisle Avenue
Spokane Valley, WA 99216FSC PROJECT NO. 21012PERMITDOCUMENTSMay 31, 2024GL8 MirabeauPoint, LLCTMK:PID: 45101.0401 10909 E. Pierce LaneSpokane, WA 99206(509) 919-0901Revision ScheduleNumber Description Date5915 S REGAL STREETSUITE 201SPOKANE, WA 99223PH: 509.473.9218Kelly@kwrllc.comwww.kwrllc.com5/30/2024 12:58:28 PMSTATE OF WASHINGTONREGISTERE
D PROFESSIONAL ENG
INEER48350 KELLY A
NDREW WATERMAN05.31.24POWER ONE-LINEDIAGRAME-601SCALE:1POWER ONE-LINE DIAGRAMNTSGENERAL NOTESFLAG NOTESPROVIDE PERMANENT LABEL AFFIXED TO SERVICE EQUIPMENTDENOTING NOMINAL SYSTEM VOLTAGE, AVAILABLE FAULT CURRENTAT SERVICE DISCONNECT, AND CLEARING TIME OF OVERCURRENTPROTECTIVE DEVICE BASED ON AVAILABLE FAULT CURRENT.PROVIDE ENERGY-REDUCING MAINTENANCE SWITCH FORCOMPLIANCE WITH NEC 240.87.PROVIDE BREAKER WITH ADJUSTABLE TRIP AND GROUND FAULTPROTECTION AS REQUIRED BY NEC 230.95.NEW CT METER BASE PER AVISTA UTILITY STANDARDS.NEW TRANSFORMER PAD / VAULT AND METERING PROVISION PERUTILITY STANDARDS.NEW UNDERGROUND PRIMARY EXTENSION PER UTILITYREQUIREMENTS. TRENCHING / GROUND SLEEVE AND CONDUIT BYCONTRACTOR. CONDUCTORS AND PRIMARY / SECONDARYTERMINATIONS BY AVISTA UTILITIES. COORDINATE FINALREQUIREMENTS WITH SERVING UTILITY.SECONDARY CONDUCTORS AND RACEWAY BY CONTRACTOR, PERAVISTA REQUIREMENTS. AVISTA TO TERMINATE SECONDARYCONDUCTORS ON UTILITY TRANSFORMER. VERIFY INSTALLATIONREQUIREMENTS WITH AVISTA PRIOR TO COMMENCEMENT OF WORK.PROVIDE BUSSMAN OR EQUIVALENT SHUNT TRIP FUSIBLE SWITCHAND CONTROL MODULE, MODEL #PS3T48-R1KGN6BF3 OR APPROVEDEQUAL. COORDINATE EXACT SIZE OF SWITCH AND FUSES WITHELEVATOR SHOP DRAWINGS AND MANUFACTURER REQUIREMENTSPRIOR TO ORDERING. COORDINATE REQUIRED FIRE ALARMCONNECTION WITH OWNER SELECTED FIRE ALARM INSTALLER.NATURAL GAS LEGALLY REQUIRED STANDBY GENERATOR (NEC 701),SIZED AS INDICATED. PROVIDE EQUIPMENT AND APPURTENANCESAND MAKE ALL CONNECTIONS FOR A COMPLETE AND FULLYOPERATIONAL SYSTEM. COORDINATE FUEL CONNECTIONS WITHCIVIL AND MECHANICAL DRAWINGS.PROVIDE 1"C BETWEEN GENERATOR AND AUTOMATIC TRANSFERSWITCH 'ATS-Y'. PROVIDE CONTROL CABLING PER MANUFACTURER'SSHOP DRAWINGS.PROVIDE 1"C BETWEEN GENERATOR AND REMOTE ANNUNCIATOR.PROVIDE CABLING PER MANUFACTURER'S SHOP DRAWINGS.PROVIDE 1"C FROM GENERATOR TO EMERGENCY POWER OFFBUTTON AND PROVIDE CABLE PER MANUFACTURER INSTRUCTIONS.PROVIDE LOW VOLTAGE CONNECTIONS TO GAS SUPPLY SOLENOIDVALVE.BOND TO BUILDING STEEL, TYPICAL FOR SEPARATELY DERIVEDSYSTEMS.SECONDARY CONDUCTORS MUST NOT EXCEED 25' PRIOR TOTERMINATING INTO DOWNSTREAM OVERCURRENT PROTECTION PERNEC 240.21(C)(6).PROVIDE TYPE 2 SURGE PROTECTION DEVICE AND ASSOCIATEDOVERCURRENT PROTECTION.SEE PANEL SCHEDULES FOR ADDITIONAL BRANCH PANELS ANDBREAKER QUANTITIES. FEEDERS ARE TYPICAL FOR SIMILAR BUSSIZES (I.E. #2 FOR100A PANELS, AND #1/0 FOR 125A PANELS).PANEL SHALL BE COOPER BUSSMAN COORDINATION MODULEPANELBOARD. SELECTIVELY COORDINATED. OVERCURRENTDEVICES SHALL BE SELECTIVELY COORDINATED PER NEC 701.32.SELECTIVELY COORDINATE OVERCURRENT DEVICE PER THEREQUIREMENTS OF NEC 701.32. MANUFACTURER TO PROVIDECOORDINATION / POWER SYSTEMS STUDY.FEEDER BETWEEN SOLAR OUTPUT BREAKER AND SOLAR INVERTEREQUIPMENT PROVIDED BY SOLAR INSTALLER. COORDINATE PHASINGWITH SOLAR INSTALLER PRIOR TO COMMENCEMENT OF WORK.1A. ALL CONDUCTORS SHALL BE COPPER, UNLESS DENOTED WITH (AL)FOR COMPACT STRANDED ALUMINUM.B. ALL CONDUCTORS SHALL BE INSTALLED CONTINUOUS (POINT TOPOINT) AND WITHOUT SPLICING, UNLESS OTHERWISE INDICATED.C. FOR CLARITY, BRANCH CIRCUITING IS NOT SHOWN ON ONE-LINEDIAGRAMS. SEE PANEL SCHEDULES.D. PROVIDE PERMANENT LABEL, AFFIXED TO EACH DISTRIBUTIONEQUIPMENT, DENOTING NOMINAL SYSTEM VOLTAGE, AVAILABLEFAULT CURRENT AT EQUIPMENT, LOCATION OF UPSTREAMDISTRIBUTION EQUIPMENT, AND DATE (MONTH AND YEAR) THELABEL WAS APPLIED. LABEL SHALL COMPLY WITH NEC 110.16(A) AND110.16(B).E. METERS SHOWN IN SWITCHBOARDS / DISTRIBUTION PANELS FORWSEC C409 REQUIREMENTS. PROVIDE INTERNAL METERING INLOCATIONS SHOWN FOR MEASURING USAGE OF END-USE LOADCATEGORIES AS OUTLINED IN WSEC SECTION C409 (HVAC, LIGHTING,EV CHARGING, PLUG LOAD). METER SHALL BE CAPABLE OFCOLLECTING AND COMMUNICATING DATA TO BUILDING TELECOMSYSTEM, INCLUDING THE FOLLOWING:-- CURRENT-- VOLTAGE-- KILOWATTS-- KILOWATT HOURS-- KILOVOLT-AMPS-- KILOVOLT-AMP HOURS-- KILOVARS-- POWER FACTORMEASUREMENTS SHALL INCLUDE PER PHASE, PEAK, AND TOTALVALUES. SOFTWARE AND PROGRAMMING SHALL BE PROVIDED FORA COMPLETE AND FUNCTIONAL METERING SOLUTION THAT CAN BEMONITORED ON-SITE.F. ALL DISTRIBUTION EQUIPMENT SHALL BE LABELED WITH THEFOLLOWING:- EQUIPMENT DESIGNATION- SOURCE FROM WHICH EQUIPMENT IS FED- VOLTAGE, PHASE, WIRING CONFIGURATION- AIC RATING- ARC-FLASH HAZARD WARNING- LOCATION OF MAIN DISCONNECT (ON UTILITY SECTION / METERSOCKET)- AVAILABLE FAULT CURRENT- DENOTE VOLTAGE COLORING SYSTEM ON LABEL:208/120V SYSTEM:480/277V SYSTEM:PHASE A BLACKBROWNPHASE B REDORANGEPHASE C BLUEYELLOWNEUTRAL WHITEWHITE/GREYGROUND GREENGREEN234567891011121314151616171819
THIRD FLOOR THIRD FLOORFOURTH FLOOR FOURTH FLOOR
FIFTH FLOOR FIFTH FLOOR100A, 480Y/277V 3P 4WPANEL 'H41'400A, 480Y/277V 3P 4WPANEL 'H5M'XFMR 'X-SDP3'225KVAP: 480V 3P 3W DELTAS: 208Y/120V 3P 4W WYEXFMR 'X-SDP4'225KVAP: 480V 3P 3W DELTAS: 208Y/120V 3P 4W WYEXFMR 'X-SDP5'225KVAP: 480V 3P 3W DELTAS: 208Y/120V 3P 4W WYETO 'MSB'TO 'MSB'TO 'MSB'TO 'MSB'TO 'MSB'DISTRIBUTION PANEL 'SDP3'208Y/120V 3P 4W42,000 AIC600A BUS 600/3LSIDISTRIBUTION PANEL 'SDP4'208Y/120V 3P 4W42,000 AIC600A BUS
600/3LSIDISTRIBUTION PANEL 'SDP5'208Y/120V 3P 4W42,000 AIC600A BUS
600/3LSI(2)4"C, 4#500KCMIL(AL),#2/0G(2)4"C, 4#500KCMIL(AL),#2/0G(2)4"C, 4#500KCMIL(AL),#2/0G100A, 208Y/120V 3P 4WPANEL 'L31'100A, 208Y/120V 3P 4WPANEL 'L41'100A, 208Y/120V 3P 4WPANEL 'L51'60A, 208Y/120V 3P 4WPANEL 'ELEV'1"C, 4#6, #8G100/31-1/2"C, 4#1, #6G100/31-1/2"C, 4#1, #6G100/31-1/2"C, 4#1, #6GELEV-2480V 3P 4W14A3/4"C, 4#8, #8GTO 'H1Y'TO 'H1Y'8813#3/013#3/013#3/060/3SPD1560/3SPD1560/3SPD1513#840/3XFMR 'X-ELEV'15KVAP: 480V 3P 3W DELTAS: 208Y/120V 3P 4W WYE1414141430A FUSES30A POWERELEVATOR MODULETO 'H1Y'30A FUSES30A POWERELEVATOR MODULEELEV-1480V 3P 4W14A3/4"C, 4#8, #8G200/3200/3200/3TO PANEL 'L33', SUBFEEDING(7) 100A PANELS AND (1) 125APANELTO PANEL 'L34', SUBFEEDING(8) 100A PANELSTO PANEL 'L35', SUBFEEDING(7) 100A PANELS200/3200/3200/3TO PANEL 'L43', SUBFEEDING(7) 100A PANELS AND (1) 125APANELTO PANEL 'L44', SUBFEEDING(8) 100A PANELSTO PANEL 'L45', SUBFEEDING(7) 100A PANELS200/3200/3200/3PANEL 'L32'208Y/120V 3P 4W200A,PANEL 'L42'208Y/120V 3P 4W200A,PANEL 'L52'208Y/120V 3P 4W200A,200/32-1/2"C,4#250KCMIL(AL),#6G200/32-1/2"C,4#250KCMIL(AL),#6G200/32-1/2"C,4#250KCMIL(AL),#6G161616125A, 208/120V 2P 3WGUEST UNIT 302 PANEL100A, 208/120V 2P 3WGUEST UNIT 304 PANEL125/23#1/0, #6G100/23#2, #8G125A, 208/120V 2P 3WGUEST UNIT 402 PANEL100A, 208/120V 2P 3WGUEST UNIT 404 PANEL125/23#1/0, #6G100/23#2, #8G125A, 208/120V 2P 3WGUEST UNIT 502 PANEL100A, 208/120V 2P 3WGUEST UNIT 504 PANEL125/23#1/0, #6G100/23#2, #8GTO PANEL 'L53', SUBFEEDING(7) 100A PANELS AND (1) 125APANELTO PANEL 'L54', SUBFEEDING(8) 100A PANELSTO PANEL 'L55', SUBFEEDING(7) 100A PANELS2-1/2"C, 4#250KCMIL(AL), #6G2-1/2"C, 4#250KCMIL(AL), #6G2-1/2"C, 4#250KCMIL(AL), #6G1718183"C, 4#350KCMIL(AL), #4G3"C, 4#350KCMIL(AL), #4G3"C, 4#350KCMIL(AL), #4G3"C, 4#350KCMIL(AL), #4G3"C, 4#350KCMIL(AL), #4G3"C, 4#350KCMIL(AL), #4G16TYP32 MERCHANT STREET, SUITE 208HONOLULU, HI 96813808-352-5299OWNER:HOMEWOOD SUITES by HILTON
SPOKANE VALLEY, WA
13515 E. Carlisle Avenue
Spokane Valley, WA 99216FSC PROJECT NO. 21012PERMITDOCUMENTSMay 31, 2024GL8 MirabeauPoint, LLCTMK:PID: 45101.0401 10909 E. Pierce LaneSpokane, WA 99206(509) 919-0901Revision ScheduleNumber Description Date5915 S REGAL STREETSUITE 201SPOKANE, WA 99223PH: 509.473.9218Kelly@kwrllc.comwww.kwrllc.com5/30/2024 12:58:38 PMSTATE OF WASHINGTONREGISTERE
D PROFESSIONAL ENG
INEER48350 KELLY A
NDREW WATERMAN05.31.24POWER ONE-LINEDIAGRAME-602SCALE:1POWER ONE-LINE DIAGRAM (CONT.)NTSGENERAL NOTESFLAG NOTESPROVIDE PERMANENT LABEL AFFIXED TO SERVICE EQUIPMENTDENOTING NOMINAL SYSTEM VOLTAGE, AVAILABLE FAULT CURRENTAT SERVICE DISCONNECT, AND CLEARING TIME OF OVERCURRENTPROTECTIVE DEVICE BASED ON AVAILABLE FAULT CURRENT.PROVIDE ENERGY-REDUCING MAINTENANCE SWITCH FORCOMPLIANCE WITH NEC 240.87.PROVIDE BREAKER WITH ADJUSTABLE TRIP AND GROUND FAULTPROTECTION AS REQUIRED BY NEC 230.95.NEW CT METER BASE PER AVISTA UTILITY STANDARDS.NEW TRANSFORMER PAD / VAULT AND METERING PROVISION PERUTILITY STANDARDS.NEW UNDERGROUND PRIMARY EXTENSION PER UTILITYREQUIREMENTS. TRENCHING / GROUND SLEEVE AND CONDUIT BYCONTRACTOR. CONDUCTORS AND PRIMARY / SECONDARYTERMINATIONS BY AVISTA UTILITIES. COORDINATE FINALREQUIREMENTS WITH SERVING UTILITY.SECONDARY CONDUCTORS AND RACEWAY BY CONTRACTOR, PERAVISTA REQUIREMENTS. AVISTA TO TERMINATE SECONDARYCONDUCTORS ON UTILITY TRANSFORMER. VERIFY INSTALLATIONREQUIREMENTS WITH AVISTA PRIOR TO COMMENCEMENT OF WORK.PROVIDE BUSSMAN OR EQUIVALENT SHUNT TRIP FUSIBLE SWITCHAND CONTROL MODULE, MODEL #PS3T48-R1KGN6BF3 OR APPROVEDEQUAL. COORDINATE EXACT SIZE OF SWITCH AND FUSES WITHELEVATOR SHOP DRAWINGS AND MANUFACTURER REQUIREMENTSPRIOR TO ORDERING. COORDINATE REQUIRED FIRE ALARMCONNECTION WITH OWNER SELECTED FIRE ALARM INSTALLER.NATURAL GAS LEGALLY REQUIRED STANDBY GENERATOR (NEC 701),SIZED AS INDICATED. PROVIDE EQUIPMENT AND APPURTENANCESAND MAKE ALL CONNECTIONS FOR A COMPLETE AND FULLYOPERATIONAL SYSTEM. COORDINATE FUEL CONNECTIONS WITHCIVIL AND MECHANICAL DRAWINGS.PROVIDE 1"C BETWEEN GENERATOR AND AUTOMATIC TRANSFERSWITCH 'ATS-Y'. PROVIDE CONTROL CABLING PER MANUFACTURER'SSHOP DRAWINGS.PROVIDE 1"C BETWEEN GENERATOR AND REMOTE ANNUNCIATOR.PROVIDE CABLING PER MANUFACTURER'S SHOP DRAWINGS.PROVIDE 1"C FROM GENERATOR TO EMERGENCY POWER OFFBUTTON AND PROVIDE CABLE PER MANUFACTURER INSTRUCTIONS.PROVIDE LOW VOLTAGE CONNECTIONS TO GAS SUPPLY SOLENOIDVALVE.BOND TO BUILDING STEEL, TYPICAL FOR SEPARATELY DERIVEDSYSTEMS.SECONDARY CONDUCTORS MUST NOT EXCEED 25' PRIOR TOTERMINATING INTO DOWNSTREAM OVERCURRENT PROTECTION PERNEC 240.21(C)(6).PROVIDE TYPE 2 SURGE PROTECTION DEVICE AND ASSOCIATEDOVERCURRENT PROTECTION.SEE PANEL SCHEDULES FOR ADDITIONAL BRANCH PANELS ANDBREAKER QUANTITIES. FEEDERS ARE TYPICAL FOR SIMILAR BUSSIZES (I.E. #2 FOR100A PANELS, AND #1/0 FOR 125A PANELS).PANEL SHALL BE COOPER BUSSMAN COORDINATION MODULEPANELBOARD. SELECTIVELY COORDINATED. OVERCURRENTDEVICES SHALL BE SELECTIVELY COORDINATED PER NEC 701.32.SELECTIVELY COORDINATE OVERCURRENT DEVICE PER THEREQUIREMENTS OF NEC 701.32. MANUFACTURER TO PROVIDECOORDINATION / POWER SYSTEMS STUDY.FEEDER BETWEEN SOLAR OUTPUT BREAKER AND SOLAR INVERTEREQUIPMENT PROVIDED BY SOLAR INSTALLER. COORDINATE PHASINGWITH SOLAR INSTALLER PRIOR TO COMMENCEMENT OF WORK.1A. ALL CONDUCTORS SHALL BE COPPER, UNLESS DENOTED WITH (AL)FOR COMPACT STRANDED ALUMINUM.B. ALL CONDUCTORS SHALL BE INSTALLED CONTINUOUS (POINT TOPOINT) AND WITHOUT SPLICING, UNLESS OTHERWISE INDICATED.C. FOR CLARITY, BRANCH CIRCUITING IS NOT SHOWN ON ONE-LINEDIAGRAMS. SEE PANEL SCHEDULES.D. PROVIDE PERMANENT LABEL, AFFIXED TO EACH DISTRIBUTIONEQUIPMENT, DENOTING NOMINAL SYSTEM VOLTAGE, AVAILABLEFAULT CURRENT AT EQUIPMENT, LOCATION OF UPSTREAMDISTRIBUTION EQUIPMENT, AND DATE (MONTH AND YEAR) THELABEL WAS APPLIED. LABEL SHALL COMPLY WITH NEC 110.16(A) AND110.16(B).E. METERS SHOWN IN SWITCHBOARDS / DISTRIBUTION PANELS FORWSEC C409 REQUIREMENTS. PROVIDE INTERNAL METERING INLOCATIONS SHOWN FOR MEASURING USAGE OF END-USE LOADCATEGORIES AS OUTLINED IN WSEC SECTION C409 (HVAC, LIGHTING,EV CHARGING, PLUG LOAD). METER SHALL BE CAPABLE OFCOLLECTING AND COMMUNICATING DATA TO BUILDING TELECOMSYSTEM, INCLUDING THE FOLLOWING:-- CURRENT-- VOLTAGE-- KILOWATTS-- KILOWATT HOURS-- KILOVOLT-AMPS-- KILOVOLT-AMP HOURS-- KILOVARS-- POWER FACTORMEASUREMENTS SHALL INCLUDE PER PHASE, PEAK, AND TOTALVALUES. SOFTWARE AND PROGRAMMING SHALL BE PROVIDED FORA COMPLETE AND FUNCTIONAL METERING SOLUTION THAT CAN BEMONITORED ON-SITE.F. ALL DISTRIBUTION EQUIPMENT SHALL BE LABELED WITH THEFOLLOWING:- EQUIPMENT DESIGNATION- SOURCE FROM WHICH EQUIPMENT IS FED- VOLTAGE, PHASE, WIRING CONFIGURATION- AIC RATING- ARC-FLASH HAZARD WARNING- LOCATION OF MAIN DISCONNECT (ON UTILITY SECTION / METERSOCKET)- AVAILABLE FAULT CURRENT- DENOTE VOLTAGE COLORING SYSTEM ON LABEL:208/120V SYSTEM:480/277V SYSTEM:PHASE A BLACKBROWNPHASE B REDORANGEPHASE C BLUEYELLOWNEUTRAL WHITEWHITE/GREYGROUND GREENGREEN234567891011121314151616171819
NEUTRAL:BUS AMPS:VOLTS:AIC:MOUNTING:LOCATION:KVA LOADCNO.CCTCIRCUIT DESCRIPTIONBAPANEL:OCPNOTESENCLOSURE:42,000800208Y/120V 3P 4WSURFACESEE PLANSSDP11100%NEMA 1200/316.8219.5720.441200/37.1510.5212.662200/30.000.000.003-/30.000.000.004100/31.640.461.455225/32.043.403.466600/333.2833.2839.94760/31.871.312.568-/30.000.000.009-/30.000.000.0010-/30.000.000.0011-/30.000.000.0012TOTAL CONNECTED KVA PER PHASETOTAL CONNECTED AMPS PER PHASETOTAL AMPSCONN. LOADTOTAL KVA(50%>10)(100%)(125%)(125%)RECEPTACLESOTHER MOTORSLARGEST MOTORLIGHTINGCALC. LOADHEATINGCONTINUOUSNONCOIN/DIVERSEKITCHEN EQUIPNONCONTINUOUS(100%)(125%)(100%)METERED DEMAND(125%)NOTES:670.74 573.1480.50 68.54211.85(100%)0.0012.9220.017.050.490.0015.8420.015.640.39COMPUTER657.65236.933.64106.8057.392.140.003.64133.5057.391.940.00(91%)(N/A)0.000.00588.0262.80524.07PANEL L11PANEL L12PANEL L13SPACEPANEL LPATPANEL L1PPANEL EVPANEL LSSSPACESPACESPACESPACENEUTRAL:BUS AMPS:VOLTS:AIC:MOUNTING:LOCATION:KVA LOADCNO.CCTCIRCUIT DESCRIPTIONBAPANEL:OCPNOTESENCLOSURE:22,000150480Y/277V 3P 4WSURFACESEE PLANSH1Y100%NEMA 130/313.3013.3013.30130/313.3013.3013.30230/30.921.540.923-/30.000.000.004-/30.000.000.005-/30.000.000.006TOTAL CONNECTED KVA PER PHASETOTAL CONNECTED AMPS PER PHASETOTAL AMPSCONN. LOADTOTAL KVA(50%>10)(100%)(125%)(125%)RECEPTACLESOTHER MOTORSLARGEST MOTORLIGHTINGCALC. LOADHEATINGCONTINUOUSNONCOIN/DIVERSEKITCHEN EQUIPNONCONTINUOUS(100%)(125%)(100%)METERED DEMAND(125%)NOTES:99.33 101.5427.52 28.1483.19(100%)0.000.7253.9035.330.380.000.7253.9028.270.30COMPUTER108.6590.330.000.000.000.000.000.000.000.000.000.00(N/A)(N/A)0.000.00100.0627.5299.33ELEV-1ELEV-2XFMR X-ELEVSPACESPACESPACE32 MERCHANT STREET, SUITE 208HONOLULU, HI 96813808-352-5299OWNER:HOMEWOOD SUITES by HILTON
SPOKANE VALLEY, WA
13515 E. Carlisle Avenue
Spokane Valley, WA 99216FSC PROJECT NO. 21012PERMITDOCUMENTSMay 31, 2024GL8 MirabeauPoint, LLCTMK:PID: 45101.0401 10909 E. Pierce LaneSpokane, WA 99206(509) 919-0901Revision ScheduleNumber Description Date5915 S REGAL STREETSUITE 201SPOKANE, WA 99223PH: 509.473.9218Kelly@kwrllc.comwww.kwrllc.com5/30/2024 1:27:14 PMSTATE OF WASHINGTONREGISTERED PROFESSIONAL ENG
INEER48350 KELLY A
N
DREW WATERMAN05.31.24PANEL SCHEDULESE-603
NEUTRAL:BUS AMPS:VOLTS:AIC:MAIN OCPD:LUGS:FED FROM:MOUNTING:LOCATION:CCTNO.NO.CCTCIRCUIT DESCRIPTIONCIRCUIT DESCRIPTIONPANEL:SEE ONE-LINE DIAGRAMENCLOSURE:KVA LOADBCCCTOCPDNOTESACCTOCPDNOTESH5MSEE PLANSSURFACE480Y/277V 3P 4W40022,000MLOSTANDARD100%NEMA 12150/36.939.7040/334 |6.939.70 |65 | |6.939.708750/36.939.7040/3910 |6.939.70 |1211 | |6.939.70141360/30.0011.0920/11516 |0.0011.0920/11817 |20/10.0011.09201920/10.000.0020/1212220/10.000.0020/1242320/120/10.000.002625-/10.000.0020/12728-/10.000.0020/13029-/120/10.000.003231-/10.000.00-/13334-/10.000.00-/13635-/1-/10.000.003837-/10.000.00-/13940-/10.000.00-/14241-/1-/10.000.00TOTAL CALCULATED AMPSCONN. KVATOTAL KVA(50%>10)(100%)(125%)(125%)RECEPTACLESOTHER MOTORSLARGEST MOTORLIGHTINGCALC. KVAHEATINGCONTINUOUSNONCOIN/DIVERSEKITCHEN EQUIPNONCONTINUOUS(100%)(125%)(100%)TOTAL CONNECTED LOAD (KVA)NOTES:METERED DEMAND(125%)COOLINGABCTOTAL CONNECTED LOAD (AMPS)ABC133.02(100%)0.000.0099.7741.570.000.000.0099.7733.260.00COMPUTER170.00141.340.000.000.000.000.000.000.000.000.000.00(N/A)(N/A)0.000.00160.000.000.00(N/A)44.3444.3444.34160.00 160.00160.00CU-02ACU-02BERV-01SPARESPARESPARESPACESPACESPACESPACESPACESPACESPACESPACESPACECU-03ACU-03BSPARESPARESPARESPARESPARESPARESPARESPARESPARESPACESPACESPACESPACESPACESPACENEUTRAL:BUS AMPS:VOLTS:AIC:MAIN OCPD:LUGS:FED FROM:MOUNTING:LOCATION:CCTNO.NO.CCTCIRCUIT DESCRIPTIONCIRCUIT DESCRIPTIONPANEL:SEE ONE-LINE DIAGRAMENCLOSURE:KVA LOADBCCCTOCPDNOTESACCTOCPDNOTESH11SEE PLANSSURFACE480Y/277V 3P 4W10042,000MLOSTANDARD100%NEMA 12120/10.000.7020/13420/10.001.1220/16520/120/10.000.788720/10.002.8020/191020/10.000.2720/1121120/120/10.000.39141320/10.001.2520/1151620/10.000.7020/11817-/120/10.000.002019-/10.000.0020/12122-/10.000.0020/12423-/120/10.000.002625-/10.000.00-/12728-/10.000.00-/13029-/1-/10.000.003231-/10.000.00-/13334-/10.000.00-/13635-/1-/10.000.003837-/10.000.00-/13940-/10.000.00-/14241-/1-/10.000.00TOTAL CALCULATED AMPSCONN. KVATOTAL KVA(50%>10)(100%)(125%)(125%)RECEPTACLESOTHER MOTORSLARGEST MOTORLIGHTINGCALC. KVAHEATINGCONTINUOUSNONCOIN/DIVERSEKITCHEN EQUIPNONCONTINUOUS(100%)(125%)(100%)TOTAL CONNECTED LOAD (KVA)NOTES:METERED DEMAND(125%)COOLINGABCTOTAL CONNECTED LOAD (AMPS)ABC8.00(100%)0.000.000.000.0010.010.000.000.000.008.00COMPUTER12.0310.010.000.000.000.000.000.000.000.000.000.00(N/A)(N/A)0.000.009.630.000.00(N/A)4.742.091.177.544.2217.13LTG, LTG - EXTLTG - EXTLTGLTGLTGLTGLTGLTGSPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPARESPARESPARESPARESPARESPARESPARESPARESPARESPARESPARESPARESPACESPACESPACESPACESPACESPACESPACESPACESPACENEUTRAL:BUS AMPS:VOLTS:AIC:MAIN OCPD:LUGS:FED FROM:MOUNTING:LOCATION:CCTNO.NO.CCTCIRCUIT DESCRIPTIONCIRCUIT DESCRIPTIONPANEL:SEE ONE-LINE DIAGRAMENCLOSURE:KVA LOADBCCCTOCPDNOTESACCTOCPDNOTESH12SEE PLANSSURFACE480Y/277V 3P 4W10010,000MLOSTANDARD100%NEMA 12120/10.001.2920/13420/10.001.0620/16520/120/10.000.918720/10.001.2120/191020/10.000.5120/11211-/120/10.000.001413-/10.000.0020/11516-/10.000.0020/11817-/120/10.000.002019-/10.000.0020/12122-/10.000.0020/12423-/120/10.000.002625-/10.000.00-/12728-/10.000.00-/13029-/1-/10.000.003231-/10.000.00-/13334-/10.000.00-/13635-/1-/10.000.003837-/10.000.00-/13940-/10.000.00-/14241-/1-/10.000.00TOTAL CALCULATED AMPSCONN. KVATOTAL KVA(50%>10)(100%)(125%)(125%)RECEPTACLESOTHER MOTORSLARGEST MOTORLIGHTINGCALC. KVAHEATINGCONTINUOUSNONCOIN/DIVERSEKITCHEN EQUIPNONCONTINUOUS(100%)(125%)(100%)TOTAL CONNECTED LOAD (KVA)NOTES:METERED DEMAND(125%)COOLINGABCTOTAL CONNECTED LOAD (AMPS)ABC4.97(100%)0.000.000.000.006.210.000.000.000.004.97COMPUTER7.476.210.000.000.000.000.000.000.000.000.000.00(N/A)(N/A)0.000.005.980.000.00(N/A)2.501.560.915.643.279.02LTGLTGLTGLTGLTGSPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPARESPARESPARESPARESPARESPARESPARESPARESPARESPARESPARESPARESPACESPACESPACESPACESPACESPACESPACESPACESPACENEUTRAL:BUS AMPS:VOLTS:AIC:MAIN OCPD:LUGS:FED FROM:MOUNTING:LOCATION:CCTNO.NO.CCTCIRCUIT DESCRIPTIONCIRCUIT DESCRIPTIONPANEL:SEE ONE-LINE DIAGRAMENCLOSURE:KVA LOADBCCCTOCPDNOTESACCTOCPDNOTESH1MSEE PLANSSURFACE480Y/277V 3P 4W20042,000MLOSTANDARD100%NEMA 12130/30.835.2715/334 |0.835.27 |65 | |0.835.278720/10.830.0015/391020/10.830.00 |121120/1 |0.830.00141320/10.000.0020/1151620/10.000.0020/1181720/120/10.000.00201920/10.000.00-/1212220/10.000.00-/1242320/1-/10.000.002625-/10.000.00-/12728-/10.000.00-/13029-/1-/10.000.003231-/10.000.00-/13334-/10.000.00-/13635-/1-/10.000.003837-/10.000.00-/13940-/10.000.00-/14241-/1-/10.000.00TOTAL CALCULATED AMPSCONN. KVATOTAL KVA(50%>10)(100%)(125%)(125%)RECEPTACLESOTHER MOTORSLARGEST MOTORLIGHTINGCALC. KVAHEATINGCONTINUOUSNONCOIN/DIVERSEKITCHEN EQUIPNONCONTINUOUS(100%)(125%)(100%)TOTAL CONNECTED LOAD (KVA)NOTES:METERED DEMAND(125%)COOLINGABCTOTAL CONNECTED LOAD (AMPS)ABC20.78(100%)0.000.004.9919.750.000.000.004.9915.800.00COMPUTER29.7524.730.000.000.000.000.000.000.000.000.000.00(N/A)(N/A)0.000.0025.000.000.00(N/A)6.936.936.9325.0025.0025.00AHU-01SPARESPARESPARESPARESPARESPARESPARESPARESPARESPACESPACESPACESPACESPACESPACESPACESPACESPACECU-01ACU-01BSPARESPARESPARESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACENEUTRAL:BUS AMPS:VOLTS:AIC:MAIN OCPD:LUGS:FED FROM:MOUNTING:LOCATION:CCTNO.NO.CCTCIRCUIT DESCRIPTIONCIRCUIT DESCRIPTIONPANEL:SEE ONE-LINE DIAGRAMENCLOSURE:KVA LOADBCCCTOCPDNOTESACCTOCPDNOTESH41SEE PLANSSURFACE480Y/277V 3P 4W10022,000MLOSTANDARD100%NEMA 12120/10.001.0120/13420/10.001.0120/16520/120/10.001.0187-/10.000.0020/1910-/10.000.0020/11211-/120/10.000.001413-/10.000.0020/11516-/10.000.0020/11817-/120/10.000.002019-/10.000.0020/12122-/10.000.0020/12423-/120/10.000.002625-/10.000.00-/12728-/10.000.00-/13029-/1-/10.000.003231-/10.000.00-/13334-/10.000.00-/13635-/1-/10.000.003837-/10.000.00-/13940-/10.000.00-/14241-/1-/10.000.00TOTAL CALCULATED AMPSCONN. KVATOTAL KVA(50%>10)(100%)(125%)(125%)RECEPTACLESOTHER MOTORSLARGEST MOTORLIGHTINGCALC. KVAHEATINGCONTINUOUSNONCOIN/DIVERSEKITCHEN EQUIPNONCONTINUOUS(100%)(125%)(100%)TOTAL CONNECTED LOAD (KVA)NOTES:METERED DEMAND(125%)COOLINGABCTOTAL CONNECTED LOAD (AMPS)ABC3.03(100%)0.000.000.000.003.790.000.000.000.003.03COMPUTER4.563.790.000.000.000.000.000.000.000.000.000.00(N/A)(N/A)0.000.003.640.000.00(N/A)1.011.011.013.653.653.65LTGLTGLTGSPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPARESPARESPARESPARESPARESPARESPARESPARESPARESPARESPARESPARESPACESPACESPACESPACESPACESPACESPACESPACESPACE32 MERCHANT STREET, SUITE 208HONOLULU, HI 96813808-352-5299OWNER:HOMEWOOD SUITES by HILTON
SPOKANE VALLEY, WA
13515 E. Carlisle Avenue
Spokane Valley, WA 99216FSC PROJECT NO. 21012PERMITDOCUMENTSMay 31, 2024GL8 MirabeauPoint, LLCTMK:PID: 45101.0401 10909 E. Pierce LaneSpokane, WA 99206(509) 919-0901Revision ScheduleNumber Description Date5915 S REGAL STREETSUITE 201SPOKANE, WA 99223PH: 509.473.9218Kelly@kwrllc.comwww.kwrllc.com5/30/2024 1:27:19 PMSTATE OF WASHINGTONREGISTERED PROFESSIONAL ENG
INEER48350 KELLY A
N
DREW WATERMAN05.31.24PANEL SCHEDULESE-604
a.PROVIDE LOCKABLE CIRCUIT BREAKER.b. PROVIDE GFCI CIRCUIT BREAKER WITH 6mA TRIP.c. PROVIDE GFP CIRCUIT BREAKER WITH 30mA TRIP.d. CIRCUIT SHALL BE ROUTED THROUGH ASSOCIATED KITCHEN HOODCONTROL PANEL. SEE HOOD SHOP DRAWINGS AND COORDINATE WITHHOOD PROVIDER PRIOR TO INSTALLATION.e. SPACE FOR SHUNT TRIP MODULE. CIRCUIT SHALL DE-ENERGIZE UPONACTIVATION OF TYPE 1 KITCHEN HOOD SYSTEM. PROVIDE CONDUCTORSFROM PANEL TO HOOD ANSUL SYSTEM. SEE MANUFACTURER WIRINGDIAGRAMS FOR ADDITIONAL INFORMATION.bbbbbbaacbbbbbbbba,ba,bbaaddeeeeeeebbabbbaaaaaaaaaaaaaaaaaa. PROVIDE LOCKABLE CIRCUIT BREAKER.b. PROVIDE GFCI CIRCUIT BREAKER WITH 6mA TRIP.c. PROVIDE CIRCUIT BREAKER WITH RED HANDLE.a. PROVIDE LOCKABLE CIRCUIT BREAKER.b. PROVIDE GFCI CIRCUIT BREAKER WITH 6mA TRIP.c. PROVIDE GFP CIRCUIT BREAKER WITH 30mA TRIP.d. CIRCUIT SHALL BE ROUTED THROUGH ASSOCIATED KITCHEN HOODCONTROL PANEL. SEE HOOD SHOP DRAWINGS AND COORDINATE WITHHOOD PROVIDER PRIOR TO INSTALLATION.e. SPACE FOR SHUNT TRIP MODULE. CIRCUIT SHALL DE-ENERGIZE UPONACTIVATION OF TYPE 1 KITCHEN HOOD SYSTEM. PROVIDE CONDUCTORSFROM PANEL TO HOOD ANSUL SYSTEM. SEE MANUFACTURER WIRINGDIAGRAMS FOR ADDITIONAL INFORMATION.aa. PROVIDE LOCKABLE CIRCUIT BREAKER.b. PROVIDE GFCI CIRCUIT BREAKER WITH 6mA TRIP.c. PROVIDE CIRCUIT BREAKER WITH RED HANDLE.a. PROVIDE LOCKABLE CIRCUIT BREAKER.b. PROVIDE GFCI CIRCUIT BREAKER WITH 6mA TRIP.c. PROVIDE CIRCUIT BREAKER WITH RED HANDLE.NEUTRAL:BUS AMPS:VOLTS:AIC:MAIN OCPD:LUGS:FED FROM:MOUNTING:LOCATION:CCTNO.NO.CCTCIRCUIT DESCRIPTIONCIRCUIT DESCRIPTIONPANEL:SEE ONE-LINE DIAGRAMENCLOSURE:KVA LOADBCCCTOCPDNOTESACCTOCPDNOTESEVSEE PLANSSURFACE208Y/120V 3P 4W60042,000MLOSTANDARD100%NEMA 12140/23.333.3340/234 |3.333.33 |6540/240/23.333.3387 |3.333.33 |91040/23.333.3340/21211 | |3.333.33141340/23.333.3340/21516 |3.333.33 |181740/240/23.333.332019 |3.333.33 |212240/23.333.3340/22423 | |3.333.33262540/23.333.3340/22728 |3.333.33 |302940/240/23.333.333231 |3.333.33 |3334-/10.000.00-/13635-/1-/10.000.003837-/10.000.00-/13940-/10.000.00-/14241-/1-/10.000.00TOTAL CALCULATED AMPSCONN. KVATOTAL KVA(50%>10)(100%)(125%)(125%)RECEPTACLESOTHER MOTORSLARGEST MOTORLIGHTINGCALC. KVAHEATINGCONTINUOUSNONCOIN/DIVERSEKITCHEN EQUIPNONCONTINUOUS(100%)(125%)(100%)TOTAL CONNECTED LOAD (KVA)NOTES:METERED DEMAND(125%)COOLINGABCTOTAL CONNECTED LOAD (AMPS)ABC106.50(100%)0.000.000.000.000.000.000.000.000.000.00COMPUTER369.50133.120.00106.500.000.000.000.00133.120.000.000.00(N/A)(N/A)0.000.00295.600.000.00(N/A)39.9433.2833.28278.97 278.97332.55EV-1EV-2EV-3 (FUTURE)EV-4 (FUTURE)EV-5 (FUTURE)EV-6 (FUTURE)EV-7 (FUTURE)EV-8 (FUTURE)SPACESPACESPACESPACESPACEEV-9 (FUTURE)EV-10 (FUTURE)EV-11 (FUTURE)EV-12 (FUTURE)EV-13 (FUTURE)EV-14 (FUTURE)EV-15 (FUTURE)EV-16 (FUTURE)SPACESPACESPACESPACESPACENEUTRAL:BUS AMPS:VOLTS:AIC:MAIN OCPD:LUGS:FED FROM:MOUNTING:LOCATION:CCTNO.NO.CCTCIRCUIT DESCRIPTIONCIRCUIT DESCRIPTIONPANEL:SEE ONE-LINE DIAGRAMENCLOSURE:KVA LOADBCCCTOCPDNOTESACCTOCPDNOTESELEVSEE PLANSSURFACE208Y/120V 3P 4W6010,00040STANDARD100%NEMA 12120/11.180.3620/13420/11.180.3620/16520/120/10.000.308720/10.000.0020/191020/10.000.0020/1121120/120/10.000.00141320/10.000.0020/1151620/10.000.0020/1181720/1-/10.000.002019-/10.000.00-/12122-/10.000.00-/12423-/1-/10.000.00TOTAL CALCULATED AMPSCONN. KVATOTAL KVA(50%>10)(100%)(125%)(125%)RECEPTACLESOTHER MOTORSLARGEST MOTORLIGHTINGCALC. KVAHEATINGCONTINUOUSNONCOIN/DIVERSEKITCHEN EQUIPNONCONTINUOUS(100%)(125%)(100%)TOTAL CONNECTED LOAD (KVA)NOTES:METERED DEMAND(125%)COOLINGABCTOTAL CONNECTED LOAD (AMPS)ABC3.38(100%)0.000.721.181.470.380.000.721.181.180.30COMPUTER10.403.750.000.000.000.000.000.000.000.000.000.00(N/A)(N/A)0.000.009.370.000.00(N/A)1.541.540.3012.802.5312.80RECRECLTGSPARESPARESPARESPARESPARESPARESPACESPACESPACESP-1SP-2SPARESPARESPARESPARESPARESPARESPACESPACESPACESPACENEUTRAL:BUS AMPS:VOLTS:AIC:MAIN OCPD:LUGS:FED FROM:MOUNTING:LOCATION:CCTNO.NO.CCTCIRCUIT DESCRIPTIONCIRCUIT DESCRIPTIONPANEL:SEE ONE-LINE DIAGRAMENCLOSURE:KVA LOADBCCCTOCPDNOTESACCTOCPDNOTESL1PSEE PLANSSURFACE208Y/120V 3P 4W22522,000MLOSTANDARD100%NEMA 4X2120/10.541.9220/13420/10.481.9220/16520/120/10.121.928720/10.600.4020/191020/10.600.4020/1121120/120/10.000.00141320/10.000.0020/1151620/10.000.0020/1181720/120/10.000.00201920/10.000.0020/1212220/10.000.0020/12423-/1-/10.000.002625-/10.000.00-/12728-/10.000.00-/13029-/1-/10.000.00TOTAL CALCULATED AMPSCONN. KVATOTAL KVA(50%>10)(100%)(125%)(125%)RECEPTACLESOTHER MOTORSLARGEST MOTORLIGHTINGCALC. KVAHEATINGCONTINUOUSNONCOIN/DIVERSEKITCHEN EQUIPNONCONTINUOUS(100%)(125%)(100%)TOTAL CONNECTED LOAD (KVA)NOTES:METERED DEMAND(125%)COOLINGABCTOTAL CONNECTED LOAD (AMPS)ABC8.89(100%)0.000.543.842.400.000.000.543.841.920.00COMPUTER26.019.370.000.002.590.000.000.000.002.590.000.00(N/A)(N/A)0.000.0024.680.000.00(N/A)3.463.402.0428.3017.0028.80PEQ-1PEQ-2PEQ-3PEQ-6PEQ-7SPARESPARESPARESPARESPARESPARESPACESPACESPACESPACERECPEQ-8.1, PEQ-8.2PEQ-9, PEQ-10PEQ-11PEQ-12SPARESPARESPARESPARESPARESPARESPACESPACESPACESPACENEUTRAL:BUS AMPS:VOLTS:AIC:MAIN OCPD:LUGS:FED FROM:MOUNTING:LOCATION:CCTNO.NO.CCTCIRCUIT DESCRIPTIONCIRCUIT DESCRIPTIONPANEL:SEE ONE-LINE DIAGRAMENCLOSURE:KVA LOADBCCCTOCPDNOTESACCTOCPDNOTESL1KASEE PLANSFLUSH208Y/120V 3P 4W40022,000MLOFEEDTHRU100%NEMA 12120/11.300.2415/13420/12.640.7830/36520/1 |2.640.868720/12.641.44 |91020/12.642.0030/3121120/1 |2.640.36141320/22.640.90 |1516 |1.510.9020/1181720/120/10.960.60201920/11.300.1915/2212220/11.300.65 |242320/120/11.300.65262520/11.000.6520/1272820/11.800.6520/1302920/120/10.501.14323120/20.370.9915/33334 |0.370.99 |363520/1 |0.371.92383720/10.830.1815/2394020/10.830.00 |424120/120/10.000.00444320/10.000.0020/14546-/10.000.0020/14847-/1-/10.000.005049-/10.000.00-/15152-/10.000.00-/15453-/1-/10.000.00TOTAL CALCULATED AMPSCONN. KVATOTAL KVA(50%>10)(100%)(125%)(125%)RECEPTACLESOTHER MOTORSLARGEST MOTORLIGHTINGCALC. KVAHEATINGCONTINUOUSNONCOIN/DIVERSEKITCHEN EQUIPNONCONTINUOUS(100%)(125%)(100%)TOTAL CONNECTED LOAD (KVA)NOTES:METERED DEMAND(125%)COOLINGABCTOTAL CONNECTED LOAD (AMPS)ABC61.38(100%)0.000.180.000.243.000.000.180.000.192.40COMPUTER116.8942.111.000.000.7056.910.001.000.000.7036.990.00(65%)(N/A)0.000.00170.380.000.00(N/A)20.0224.1417.22202.50 144.15171.12KE-2.1KE-2.2KE-2KE-41KE-50KE-31KE-20KE-7KE-7.1KE-61AKE-61BKE-61CKE-61DKE-89KE-85KE-84RECSPARESPARESPARESPACESPACESPACESPACESPACEKE-26KE-22BKE-22AKE-56KE-30KE-60KE-29WALK-IN CONDENSATE LINE HEAT TRACEH-1H-1.1MAU-01EF-03SPARESPARESPARESPACESPACESPACESPACENEUTRAL:BUS AMPS:VOLTS:AIC:MAIN OCPD:LUGS:FED FROM:MOUNTING:LOCATION:CCTNO.NO.CCTCIRCUIT DESCRIPTIONCIRCUIT DESCRIPTIONPANEL:SEE ONE-LINE DIAGRAMENCLOSURE:KVA LOADBCCCTOCPDNOTESACCTOCPDNOTESLPATSEE PLANSSURFACE208Y/120V 3P 4W10010,000MLOSTANDARD100%NEMA 12120/10.360.1020/13420/10.360.1020/16520/120/10.900.748720/10.900.0920/191020/10.000.0020/1121120/120/10.000.00141320/10.000.0020/1151620/10.000.0020/1181720/120/10.000.00201920/10.000.0020/12122-/10.000.00-/12423-/1-/10.000.002625-/10.000.00-/12728-/10.000.00-/13029-/1-/10.000.003231-/10.000.00-/13334-/10.000.00-/13635-/1-/10.000.003837-/10.000.00-/13940-/10.000.00-/14241-/1-/10.000.00TOTAL CALCULATED AMPSCONN. KVATOTAL KVA(50%>10)(100%)(125%)(125%)RECEPTACLESOTHER MOTORSLARGEST MOTORLIGHTINGCALC. KVAHEATINGCONTINUOUSNONCOIN/DIVERSEKITCHEN EQUIPNONCONTINUOUS(100%)(125%)(100%)TOTAL CONNECTED LOAD (KVA)NOTES:METERED DEMAND(125%)COOLINGABCTOTAL CONNECTED LOAD (AMPS)ABC3.55(100%)0.002.520.000.000.110.002.520.000.000.09COMPUTER9.653.480.000.000.000.940.000.000.000.000.850.00(90%)(N/A)0.000.009.860.000.00(N/A)1.450.461.643.8313.7012.06KE-96AKE-96BKE-98LTGSPARESPARESPARESPARESPARESPARESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACEFIREPLACE IGNITERRECRECRECSPARESPARESPARESPARESPARESPARESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACENEUTRAL:BUS AMPS:VOLTS:AIC:MAIN OCPD:LUGS:FED FROM:MOUNTING:LOCATION:CCTNO.NO.CCTCIRCUIT DESCRIPTIONCIRCUIT DESCRIPTIONPANEL:SEE ONE-LINE DIAGRAMENCLOSURE:KVA LOADBCCCTOCPDNOTESACCTOCPDNOTESLSSSEE PLANSSURFACE208Y/120V 3P 4W6010,00060STANDARD100%NEMA 12120/10.590.1020/23420/10.590.72 |6530/220/10.001.8787 |0.001.8720/191020/10.000.0020/1121120/120/10.000.00141320/10.000.0020/1151620/10.000.0020/1181720/1-/10.000.00201920/10.000.00-/12122-/10.000.00-/12423-/1-/10.000.002625-/10.000.00-/12728-/10.000.00-/13029-/1-/10.000.003231-/10.000.00-/13334-/10.000.00-/13635-/1-/10.000.003837-/10.000.00-/13940-/10.000.00-/14241-/1-/10.000.00TOTAL CALCULATED AMPSCONN. KVATOTAL KVA(50%>10)(100%)(125%)(125%)RECEPTACLESOTHER MOTORSLARGEST MOTORLIGHTINGCALC. KVAHEATINGCONTINUOUSNONCOIN/DIVERSEKITCHEN EQUIPNONCONTINUOUS(100%)(125%)(100%)TOTAL CONNECTED LOAD (KVA)NOTES:METERED DEMAND(125%)COOLINGABCTOTAL CONNECTED LOAD (AMPS)ABC5.74(100%)0.000.721.184.680.130.000.721.183.740.10COMPUTER18.616.700.000.000.000.000.000.000.000.000.000.00(N/A)(N/A)0.000.0015.940.000.00(N/A)2.561.311.8711.2618.0022.21LTGRECUH-02SPARESPARESPARESPARESPARESPARESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACEOD-1SPARESPARESPARESPARESPARESPARESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACENEUTRAL:BUS AMPS:VOLTS:AIC:MAIN OCPD:LUGS:FED FROM:MOUNTING:LOCATION:CCTNO.NO.CCTCIRCUIT DESCRIPTIONCIRCUIT DESCRIPTIONPANEL:SEE ONE-LINE DIAGRAMENCLOSURE:KVA LOADBCCCTOCPDNOTESACCTOCPDNOTESL1KBSEE PLANSFLUSH208Y/120V 3P 4W40022,000MLOSTANDARD100%NEMA 12120/11.301.3920/234-/11.300.00 |6520/1-/10.000.3687-/11.300.0020/291030/21.302.91 |1211 |-/10.002.911413-/11.350.0020/2151620/11.350.20 |1817-/1-/10.000.00201920/10.000.0020/1212220/10.000.0020/1242320/120/10.000.002625-/10.000.00-/12728-/10.000.00-/13029-/1-/10.000.003231-/10.000.00-/13334-/10.000.00-/13635-/1-/10.000.003837-/10.000.00-/13940-/10.000.00-/14241-/1-/10.000.00TOTAL CALCULATED AMPSCONN. KVATOTAL KVA(50%>10)(100%)(125%)(125%)RECEPTACLESOTHER MOTORSLARGEST MOTORLIGHTINGCALC. KVAHEATINGCONTINUOUSNONCOIN/DIVERSEKITCHEN EQUIPNONCONTINUOUS(100%)(125%)(100%)TOTAL CONNECTED LOAD (KVA)NOTES:METERED DEMAND(125%)COOLINGABCTOTAL CONNECTED LOAD (AMPS)ABC15.68(100%)0.000.000.000.000.000.000.000.000.000.00COMPUTER28.4810.260.000.000.2015.480.000.000.000.2010.060.00(65%)(N/A)0.000.0043.510.000.00(N/A)5.347.063.2759.0230.6348.38KE-42BSPACE FOR SHUNT TRIP MODULEKE-48SPACE FOR SHUNT TRIP MODULEKE-42ASPACE FOR SHUNT TRIP MODULEGAS SOLENOIDSPACE FOR SHUNT TRIP MODULESPARESPARESPARESPACESPACESPACESPACESPACESPACESPACESPACESPACEKE-49BSPACE FOR SHUNT TRIP MODULEKE-49ASPACE FOR SHUNT TRIP MODULEKE-47SPACE FOR SHUNT TRIP MODULESPARESPARESPARESPACESPACESPACESPACESPACESPACESPACESPACESPACE32 MERCHANT STREET, SUITE 208HONOLULU, HI 96813808-352-5299OWNER:HOMEWOOD SUITES by HILTON
SPOKANE VALLEY, WA
13515 E. Carlisle Avenue
Spokane Valley, WA 99216FSC PROJECT NO. 21012PERMITDOCUMENTSMay 31, 2024GL8 MirabeauPoint, LLCTMK:PID: 45101.0401 10909 E. Pierce LaneSpokane, WA 99206(509) 919-0901Revision ScheduleNumber Description Date5915 S REGAL STREETSUITE 201SPOKANE, WA 99223PH: 509.473.9218Kelly@kwrllc.comwww.kwrllc.com5/30/2024 1:27:28 PMSTATE OF WASHINGTONREGISTERED PROFESSIONAL ENG
INEER48350 KELLY A
N
DREW WATERMAN05.31.24PANEL SCHEDULESE-605
a.PANEL SCHEDULE SHOWN FOR BREAKER QUANTITIES AND PHASE / LOADBALANCING. SEE ALTERNATE CALCULATIONS ON SHEET E-603 FOR CALCULATEDLOAD BASED UPON NEC ALLOWABLE DEMAND FACTORS.bbbbbbbbbbbbbaaaaacaaaabaaa. PROVIDE LOCKABLE CIRCUIT BREAKER.b. PROVIDE GFCI CIRCUIT BREAKER WITH 6mA TRIP.c. PROVIDE CIRCUIT BREAKER WITH RED HANDLE.a. PROVIDE LOCKABLE CIRCUIT BREAKER.b. PROVIDE GFCI CIRCUIT BREAKER WITH 6mA TRIP.c. PROVIDE CIRCUIT BREAKER WITH RED HANDLE.a. PROVIDE LOCKABLE CIRCUIT BREAKER.b. PROVIDE GFCI CIRCUIT BREAKER WITH 6mA TRIP.c. PROVIDE CIRCUIT BREAKER WITH RED HANDLE.ccccNEUTRAL:BUS AMPS:VOLTS:AIC:MAIN OCPD:LUGS:FED FROM:MOUNTING:LOCATION:CCTNO.NO.CCTCIRCUIT DESCRIPTIONCIRCUIT DESCRIPTIONPANEL:SEE ONE-LINE DIAGRAMENCLOSURE:KVA LOADBCCCTOCPDNOTESACCTOCPDNOTESL16SEE PLANSSURFACE208Y/120V 3P 4W20010,000MLOSTANDARD100%NEMA 121100/25.805.72100/234 |5.415.59 |65100/2100/25.725.7287 |5.595.59 |910100/25.805.72100/21211 | |5.775.591413100/25.805.80100/21516 |5.765.77 |1817100/2-/10.005.802019 |0.005.41-/12122-/10.000.00-/12423-/1-/10.000.002625-/10.000.00-/12728-/10.000.00-/13029-/1-/10.000.00TOTAL CALCULATED AMPSCONN. KVATOTAL KVA(50%>10)(100%)(125%)(125%)RECEPTACLESOTHER MOTORSLARGEST MOTORLIGHTINGCALC. KVAHEATINGCONTINUOUSNONCOIN/DIVERSEKITCHEN EQUIPNONCONTINUOUS(100%)(125%)(100%)TOTAL CONNECTED LOAD (KVA)NOTES:METERED DEMAND(125%)COOLINGABCTOTAL CONNECTED LOAD (AMPS)ABC102.32(100%)0.0013.910.000.006.710.0017.820.000.005.37COMPUTER276.8899.750.000.0079.130.000.000.000.0079.130.000.00(N/A)(N/A)0.000.00284.000.000.00(N/A)39.7034.0328.59284.93 238.56330.99PANEL A-129PANEL A-131PANEL A-133PANEL F-135PANEL B-137SPACESPACESPACESPACESPACEPANEL B-130PANEL A-134PANEL F-136PANEL D-138SPACESPACESPACESPACESPACESPACESPACENEUTRAL:BUS AMPS:VOLTS:AIC:MAIN OCPD:LUGS:FED FROM:MOUNTING:LOCATION:CCTNO.NO.CCTCIRCUIT DESCRIPTIONCIRCUIT DESCRIPTIONPANEL:SEE ONE-LINE DIAGRAMENCLOSURE:KVA LOADBCCCTOCPDNOTESACCTOCPDNOTESL11SEE PLANSSURFACE208Y/120V 3P 4W20042,000MLOSTANDARD100%NEMA 12115/31.441.2015/334 |1.441.20 |65 | |1.441.208715/31.441.2015/3910 |1.441.20 |1211 | |1.441.20141315/31.441.2015/31516 |1.441.20 |1817 | |1.441.20201920/12.381.8030/2212220/12.381.80 |242320/130/22.381.80262520/12.381.80 |272820/12.380.8030/2302920/1 |2.381.20323120/12.381.0030/2333420/12.380.60 |363520/120/10.540.60383720/10.190.6020/1394020/10.720.6020/1424120/120/10.000.00444320/10.000.0020/1454620/10.000.0020/14847-/1-/10.000.005049-/10.000.00-/15152-/10.000.00-/15453-/1-/10.000.00TOTAL CALCULATED AMPSCONN. KVATOTAL KVA(50%>10)(100%)(125%)(125%)RECEPTACLESOTHER MOTORSLARGEST MOTORLIGHTINGCALC. KVAHEATINGCONTINUOUSNONCOIN/DIVERSEKITCHEN EQUIPNONCONTINUOUS(100%)(125%)(100%)TOTAL CONNECTED LOAD (KVA)NOTES:METERED DEMAND(125%)COOLINGABCTOTAL CONNECTED LOAD (AMPS)ABC56.83(100%)0.000.002.530.750.000.000.002.530.600.00COMPUTER158.1656.980.000.0052.501.200.000.000.0052.501.200.00(100%)(N/A)0.000.00157.740.000.00(N/A)20.4419.5716.82163.40 140.05170.65WASH-2.1WASH-2.2WASH-2.3WASH-1.1WASH-1.2WASH-1.3WASH-1.4REF-1DW-1MW-1TREAD-1TREAD-2TREAD-3TREAD-4SPARESPARESPARESPACESPACESPACESPACEDRY-2.1DRY-2.2DRY-2.3DRY-1.1DRY-1.2DRY-1.3DRY-1.4BIKE-1, ELLIP-1, ELLIP-2ICE-1DF-1SPARESPARESPARESPACESPACESPACESPACENEUTRAL:BUS AMPS:VOLTS:AIC:MAIN OCPD:LUGS:FED FROM:MOUNTING:LOCATION:CCTNO.NO.CCTCIRCUIT DESCRIPTIONCIRCUIT DESCRIPTIONPANEL:SEE ONE-LINE DIAGRAMENCLOSURE:KVA LOADBCCCTOCPDNOTESACCTOCPDNOTESL13SEE PLANSSURFACE208Y/120V 3P 4W20042,000MLOSTANDARD100%NEMA 12120/10.000.0020/13420/10.000.0020/16520/120/10.000.008720/10.000.0020/191020/10.000.0020/1121120/120/10.000.001413-/10.000.00-/11516-/10.000.00-/11817-/1-/10.000.002019-/10.000.00-/12122-/10.000.00-/12423-/1-/10.000.002625-/10.000.00-/12728-/10.000.00-/13029-/1-/10.000.003231-/10.000.00-/13334-/10.000.00-/13635-/1-/10.000.003837-/10.000.00-/13940-/10.000.00-/14241-/1-/10.000.004443-/10.000.00-/14546-/10.000.00-/14847-/1-/10.000.005049-/10.000.00-/15152-/10.000.00-/15453-/1-/10.000.00TOTAL CALCULATED AMPSCONN. KVATOTAL KVA(50%>10)(100%)(125%)(125%)RECEPTACLESOTHER MOTORSLARGEST MOTORLIGHTINGCALC. KVAHEATINGCONTINUOUSNONCOIN/DIVERSEKITCHEN EQUIPNONCONTINUOUS(100%)(125%)(100%)TOTAL CONNECTED LOAD (KVA)NOTES:METERED DEMAND(125%)COOLINGABCTOTAL CONNECTED LOAD (AMPS)ABC0.00(100%)0.000.000.000.000.000.000.000.000.000.00COMPUTER0.000.000.000.000.000.000.000.000.000.000.000.00(N/A)(N/A)0.000.000.000.000.00(N/A)0.000.000.000.000.000.00SPARESPARESPARESPARESPARESPARESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPARESPARESPARESPARESPARESPARESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACENEUTRAL:BUS AMPS:VOLTS:AIC:MAIN OCPD:LUGS:FED FROM:MOUNTING:LOCATION:CCTNO.NO.CCTCIRCUIT DESCRIPTIONCIRCUIT DESCRIPTIONPANEL:SEE ONE-LINE DIAGRAMENCLOSURE:KVA LOADBCCCTOCPDNOTESACCTOCPDNOTESL14ASEE PLANSSURFACE208Y/120V 3P 4W20022,000MLOFEEDTHRU100%NEMA 12115/20.721.3720/134 |0.601.3720/16520/120/11.201.008720/10.361.3320/191020/10.720.3620/1121120/120/10.720.36141320/10.720.3620/1151620/11.080.3620/1181720/120/10.900.36201920/10.721.0820/1212220/10.720.7220/1242320/120/10.720.72262520/10.720.7220/1272820/11.080.3620/1302920/120/10.700.36323120/10.410.2020/1333420/10.000.0020/1363520/120/10.000.00383720/10.000.0020/1394020/10.000.0020/1424120/120/10.000.00TOTAL CALCULATED AMPSCONN. KVATOTAL KVA(50%>10)(100%)(125%)(125%)RECEPTACLESOTHER MOTORSLARGEST MOTORLIGHTINGCALC. KVAHEATINGCONTINUOUSNONCOIN/DIVERSEKITCHEN EQUIPNONCONTINUOUS(100%)(125%)(100%)TOTAL CONNECTED LOAD (KVA)NOTES:METERED DEMAND(125%)COOLINGABCTOTAL CONNECTED LOAD (AMPS)ABC23.13(100%)0.0012.112.372.131.380.0014.222.371.711.11COMPUTER60.2921.721.000.002.720.000.001.000.002.720.000.00(N/A)(N/A)0.000.0064.190.000.00(N/A)8.717.377.0461.7958.6772.90FCU-215, FCU-216, FCU-217EH-12ADA DOOR MOTORRECRECRECRECRECRECRECRECRECRECRECDOOR MAG HOLDSPARESPARESPARESPARESPAREDF-2PRINT-1COPY-1RECRECRECRECRECRECRECRECRECRECRECCASEWORK LIGHTING CONNECTION, SWEET SHOP SIGNAGELTGSPARESPARESPARESPARESPARENEUTRAL:BUS AMPS:VOLTS:AIC:MAIN OCPD:LUGS:FED FROM:MOUNTING:LOCATION:CCTNO.NO.CCTCIRCUIT DESCRIPTIONCIRCUIT DESCRIPTIONPANEL:SEE ONE-LINE DIAGRAMENCLOSURE:KVA LOADBCCCTOCPDNOTESACCTOCPDNOTESL14BSEE PLANSSURFACE208Y/120V 3P 4W20022,000MLOSTANDARD100%NEMA 12120/10.000.0020/13420/10.000.0020/16520/120/10.000.008720/10.000.0020/191020/10.000.0020/1121120/120/10.000.001413-/10.000.00-/11516-/10.000.00-/11817-/1-/10.000.002019-/10.000.00-/12122-/10.000.00-/12423-/1-/10.000.002625-/10.000.00-/12728-/10.000.00-/13029-/1-/10.000.003231-/10.000.00-/13334-/10.000.00-/13635-/1-/10.000.003837-/10.000.00-/13940-/10.000.00-/14241-/1-/10.000.00TOTAL CALCULATED AMPSCONN. KVATOTAL KVA(50%>10)(100%)(125%)(125%)RECEPTACLESOTHER MOTORSLARGEST MOTORLIGHTINGCALC. KVAHEATINGCONTINUOUSNONCOIN/DIVERSEKITCHEN EQUIPNONCONTINUOUS(100%)(125%)(100%)TOTAL CONNECTED LOAD (KVA)NOTES:METERED DEMAND(125%)COOLINGABCTOTAL CONNECTED LOAD (AMPS)ABC0.00(100%)0.000.000.000.000.000.000.000.000.000.00COMPUTER0.000.000.000.000.000.000.000.000.000.000.000.00(N/A)(N/A)0.000.000.000.000.00(N/A)0.000.000.000.000.000.00SPARESPARESPARESPARESPARESPARESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPARESPARESPARESPARESPARESPARESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACENEUTRAL:BUS AMPS:VOLTS:AIC:MAIN OCPD:LUGS:FED FROM:MOUNTING:LOCATION:CCTNO.NO.CCTCIRCUIT DESCRIPTIONCIRCUIT DESCRIPTIONPANEL:SEE ONE-LINE DIAGRAMENCLOSURE:KVA LOADBCCCTOCPDNOTESACCTOCPDNOTESL12SEE PLANSSURFACE208Y/120V 3P 4W20042,000MLOSTANDARD100%NEMA 12120/12.820.6035/23420/12.820.60 |6520/120/10.240.608720/11.800.6020/191015/20.580.8320/11211 |20/10.120.83141320/11.000.2020/1151620/10.920.2015/2181720/1 |0.920.04201920/10.541.2020/1212220/10.900.5420/1242320/120/11.080.72262520/11.080.9020/1272820/10.901.0820/1302920/120/11.080.72323120/10.900.7220/1333420/10.360.3020/1363520/120/10.170.54383720/10.100.2020/1394020/10.200.3020/1424120/120/10.000.10444320/10.000.0020/1454620/10.000.0020/1484720/120/10.000.00504920/10.000.0020/1515220/10.000.0020/1545320/120/10.000.00TOTAL CALCULATED AMPSCONN. KVATOTAL KVA(50%>10)(100%)(125%)(125%)RECEPTACLESOTHER MOTORSLARGEST MOTORLIGHTINGCALC. KVAHEATINGCONTINUOUSNONCOIN/DIVERSEKITCHEN EQUIPNONCONTINUOUS(100%)(125%)(100%)TOTAL CONNECTED LOAD (KVA)NOTES:METERED DEMAND(125%)COOLINGABCTOTAL CONNECTED LOAD (AMPS)ABC30.33(100%)0.0011.036.207.050.250.0012.066.205.640.20COMPUTER85.6030.843.640.302.300.000.003.640.382.300.000.00(N/A)(N/A)0.000.0084.200.000.00(N/A)12.6610.527.1587.8360.17106.34WH-1WH-2WH-3WH-4BCU-1, FCU-211, FCU-212FIRE SMOKE DAMPERDRIVEWAY SIGNFP-1, FP-2, FP-3DRIVEWAY SIGN, MONUMENT SIGNRECRECRECRECRECRECGATEWAYRECMOTORIZED SHADESFIRE ALARM SPRINKLER BELLDOOR MAG HOLDSPARESPARESPARESPARESPARESPAREUH-01DH-01WS-01DHWP-1DHWP-2EH-11FCU-213, FCU-214, FCU-311RECRECRECRECRECRECRECRECLTGLTG CONTROL ANTENNA PSFIRE ALARM CONTROL PANELSPARESPARESPARESPARESPARESPARESPARE32 MERCHANT STREET, SUITE 208HONOLULU, HI 96813808-352-5299OWNER:HOMEWOOD SUITES by HILTON
SPOKANE VALLEY, WA
13515 E. Carlisle Avenue
Spokane Valley, WA 99216FSC PROJECT NO. 21012PERMITDOCUMENTSMay 31, 2024GL8 MirabeauPoint, LLCTMK:PID: 45101.0401 10909 E. Pierce LaneSpokane, WA 99206(509) 919-0901Revision ScheduleNumber Description Date5915 S REGAL STREETSUITE 201SPOKANE, WA 99223PH: 509.473.9218Kelly@kwrllc.comwww.kwrllc.com5/30/2024 1:27:33 PMSTATE OF WASHINGTONREGISTERED PROFESSIONAL ENG
INEER48350 KELLY A
N
DREW WATERMAN05.31.24PANEL SCHEDULESE-606(SEE NOTE 'a')
a.PANEL SCHEDULE SHOWN FOR BREAKER QUANTITIES AND PHASE / LOADBALANCING. SEE ALTERNATE CALCULATIONS ON SHEET E-603 FOR CALCULATEDLOAD BASED UPON NEC ALLOWABLE DEMAND FACTORS.a. PANEL SCHEDULE SHOWN FOR BREAKER QUANTITIES AND PHASE / LOADBALANCING. SEE ALTERNATE CALCULATIONS ON SHEET E-603 FOR CALCULATEDLOAD BASED UPON NEC ALLOWABLE DEMAND FACTORS.a. PANEL SCHEDULE SHOWN FOR BREAKER QUANTITIES AND PHASE / LOADBALANCING. SEE ALTERNATE CALCULATIONS ON SHEET E-603 FOR CALCULATEDLOAD BASED UPON NEC ALLOWABLE DEMAND FACTORS.a. PANEL SCHEDULE SHOWN FOR BREAKER QUANTITIES AND PHASE / LOADBALANCING. SEE ALTERNATE CALCULATIONS ON SHEET E-603 FOR CALCULATEDLOAD BASED UPON NEC ALLOWABLE DEMAND FACTORS.a. PROVIDE LOCKABLE CIRCUIT BREAKER.b. PROVIDE GFCI CIRCUIT BREAKER WITH 6mA TRIP.c. PROVIDE CIRCUIT BREAKER WITH RED HANDLE.aaccNEUTRAL:BUS AMPS:VOLTS:AIC:MAIN OCPD:LUGS:FED FROM:MOUNTING:LOCATION:CCTNO.NO.CCTCIRCUIT DESCRIPTIONCIRCUIT DESCRIPTIONPANEL:SEE ONE-LINE DIAGRAMENCLOSURE:KVA LOADBCCCTOCPDNOTESACCTOCPDNOTESL24SEE PLANSSURFACE208Y/120V 3P 4W20010,000MLOSTANDARD100%NEMA 121100/25.725.80100/234 |5.595.41 |65100/2100/25.725.8087 |5.595.41 |910100/25.805.72100/21211 | |5.775.591413100/25.805.72100/21516 |5.415.59 |1817-/1-/10.000.002019-/10.000.00-/12122-/10.000.00-/12423-/1-/10.000.002625-/10.000.00-/12728-/10.000.00-/13029-/1-/10.000.00TOTAL CALCULATED AMPSCONN. KVATOTAL KVA(50%>10)(100%)(125%)(125%)RECEPTACLESOTHER MOTORSLARGEST MOTORLIGHTINGCALC. KVAHEATINGCONTINUOUSNONCOIN/DIVERSEKITCHEN EQUIPNONCONTINUOUS(100%)(125%)(100%)TOTAL CONNECTED LOAD (KVA)NOTES:METERED DEMAND(125%)COOLINGABCTOTAL CONNECTED LOAD (AMPS)ABC90.40(100%)0.0012.740.000.005.920.0015.480.000.004.74COMPUTER246.6188.840.000.0070.180.000.000.000.0070.180.000.00(N/A)(N/A)0.000.00250.930.000.00(N/A)34.0333.5022.87280.54 190.51284.88PANEL B-223PANEL B-225PANEL A-227PANEL A-229SPACESPACESPACESPACESPACESPACESPACEPANEL A-231PANEL A-233PANEL F-235PANEL B-237SPACESPACESPACESPACESPACESPACESPACENEUTRAL:BUS AMPS:VOLTS:AIC:MAIN OCPD:LUGS:FED FROM:MOUNTING:LOCATION:CCTNO.NO.CCTCIRCUIT DESCRIPTIONCIRCUIT DESCRIPTIONPANEL:SEE ONE-LINE DIAGRAMENCLOSURE:KVA LOADBCCCTOCPDNOTESACCTOCPDNOTESL25SEE PLANSSURFACE208Y/120V 3P 4W20010,000MLOSTANDARD100%NEMA 121100/25.805.80100/234 |5.415.77 |65100/2100/25.725.8087 |5.595.41 |910100/25.805.72100/21211 | |5.775.591413-/15.800.00100/21516-/15.760.00 |1817-/1-/10.000.002019-/10.000.00-/12122-/10.000.00-/12423-/1-/10.000.002625-/10.000.00-/12728-/10.000.00-/13029-/1-/10.000.00TOTAL CALCULATED AMPSCONN. KVATOTAL KVA(50%>10)(100%)(125%)(125%)RECEPTACLESOTHER MOTORSLARGEST MOTORLIGHTINGCALC. KVAHEATINGCONTINUOUSNONCOIN/DIVERSEKITCHEN EQUIPNONCONTINUOUS(100%)(125%)(100%)TOTAL CONNECTED LOAD (KVA)NOTES:METERED DEMAND(125%)COOLINGABCTOTAL CONNECTED LOAD (AMPS)ABC79.71(100%)0.0011.930.000.005.340.0013.860.000.004.27COMPUTER218.8678.850.000.0061.580.000.000.000.0061.580.000.00(N/A)(N/A)0.000.00221.260.000.00(N/A)28.3928.4522.87237.39 190.51236.96PANEL F-224PANEL B-226PANEL A-228SPACESPACESPACESPACESPACESPACESPACESPACESPACEPANEL B-230PANEL A-234PANEL F-236PANEL D-238SPACESPACESPACESPACESPACESPACESPACENEUTRAL:BUS AMPS:VOLTS:AIC:MAIN OCPD:LUGS:FED FROM:MOUNTING:LOCATION:CCTNO.NO.CCTCIRCUIT DESCRIPTIONCIRCUIT DESCRIPTIONPANEL:SEE ONE-LINE DIAGRAMENCLOSURE:KVA LOADBCCCTOCPDNOTESACCTOCPDNOTESL21SEE PLANSSURFACE208Y/120V 3P 4W10022,000MLOSTANDARD100%NEMA 12115/21.000.6120/134 |1.000.6120/16520/120/10.200.728720/11.440.3620/291020/11.441.08 |121120/120/10.620.36141320/10.300.3620/1151620/10.000.3620/1181720/120/10.000.36201920/10.000.3620/1212220/10.000.7220/1242320/120/10.000.72262520/10.001.0820/1272820/10.000.2020/1302920/120/10.000.183231-/10.000.0020/13334-/10.000.0020/13635-/120/10.000.003837-/10.000.0020/13940-/10.000.00-/14241-/1-/10.000.00TOTAL CALCULATED AMPSCONN. KVATOTAL KVA(50%>10)(100%)(125%)(125%)RECEPTACLESOTHER MOTORSLARGEST MOTORLIGHTINGCALC. KVAHEATINGCONTINUOUSNONCOIN/DIVERSEKITCHEN EQUIPNONCONTINUOUS(100%)(125%)(100%)TOTAL CONNECTED LOAD (KVA)NOTES:METERED DEMAND(125%)COOLINGABCTOTAL CONNECTED LOAD (AMPS)ABC14.08(100%)0.006.661.843.600.380.006.661.842.880.30COMPUTER41.3014.882.000.000.400.000.002.000.000.400.000.00(N/A)(N/A)0.000.0039.090.000.00(N/A)5.515.413.1646.1526.3346.96FCU-321, FCU-322, FCU-323, FCU-324, FCU-325, FCU-326, FCU-421RECRECRECRECRECRECRECRECRECRECRECDOOR MAG HOLDRECSPACESPACESPACESPACESPACESPACEEH-21EH-22FIRE SMOKE DAMPEREF-01DAMPER ACTUATOR, EF-02LTGSPARESPARESPARESPARESPARESPARESPARESPARESPARESPARESPARESPARESPACESPACENEUTRAL:BUS AMPS:VOLTS:AIC:MAIN OCPD:LUGS:FED FROM:MOUNTING:LOCATION:CCTNO.NO.CCTCIRCUIT DESCRIPTIONCIRCUIT DESCRIPTIONPANEL:SEE ONE-LINE DIAGRAMENCLOSURE:KVA LOADBCCCTOCPDNOTESACCTOCPDNOTESL22SEE PLANSSURFACE208Y/120V 3P 4W20022,000MLOSTANDARD100%NEMA 121125/25.8011.58100/234 |5.7712.57 |65100/2100/25.805.8087 |5.415.41 |910100/25.805.72100/21211 | |5.415.591413100/25.805.80100/21516 |5.415.77 |1817-/1-/10.000.002019-/10.000.00-/12122-/10.000.00-/12423-/1-/10.000.002625-/10.000.00-/12728-/10.000.00-/13029-/1-/10.000.00TOTAL CALCULATED AMPSCONN. KVATOTAL KVA(50%>10)(100%)(125%)(125%)RECEPTACLESOTHER MOTORSLARGEST MOTORLIGHTINGCALC. KVAHEATINGCONTINUOUSNONCOIN/DIVERSEKITCHEN EQUIPNONCONTINUOUS(100%)(125%)(100%)TOTAL CONNECTED LOAD (KVA)NOTES:METERED DEMAND(125%)COOLINGABCTOTAL CONNECTED LOAD (AMPS)ABC103.42(100%)0.0012.740.000.006.480.0015.480.000.005.18COMPUTER283.05101.970.000.0082.760.000.000.000.0082.760.000.00(N/A)(N/A)0.000.00287.060.000.00(N/A)39.7941.0322.59346.23 188.21336.06PANEL E-202PANEL B-204PANEL A-208PANEL F-210SPACESPACESPACESPACESPACESPACESPACEPANEL F-212PANEL B-214PANEL B-216PANEL B-218SPACESPACESPACESPACESPACESPACESPACENEUTRAL:BUS AMPS:VOLTS:AIC:MAIN OCPD:LUGS:FED FROM:MOUNTING:LOCATION:CCTNO.NO.CCTCIRCUIT DESCRIPTIONCIRCUIT DESCRIPTIONPANEL:SEE ONE-LINE DIAGRAMENCLOSURE:KVA LOADBCCCTOCPDNOTESACCTOCPDNOTESL23SEE PLANSSURFACE208Y/120V 3P 4W20022,000MLOSTANDARD100%NEMA 121125/25.8011.58100/234 |5.4112.57 |65100/2100/25.805.7887 |5.415.76 |910100/25.805.72100/21211 | |5.415.591413-/15.800.00100/21516-/15.770.00 |1817-/1-/10.000.002019-/10.000.00-/12122-/10.000.00-/12423-/1-/10.000.002625-/10.000.00-/12728-/10.000.00-/13029-/1-/10.000.00TOTAL CALCULATED AMPSCONN. KVATOTAL KVA(50%>10)(100%)(125%)(125%)RECEPTACLESOTHER MOTORSLARGEST MOTORLIGHTINGCALC. KVAHEATINGCONTINUOUSNONCOIN/DIVERSEKITCHEN EQUIPNONCONTINUOUS(100%)(125%)(100%)TOTAL CONNECTED LOAD (KVA)NOTES:METERED DEMAND(125%)COOLINGABCTOTAL CONNECTED LOAD (AMPS)ABC92.18(100%)0.0011.750.000.005.650.0013.500.000.004.52COMPUTER254.1491.560.000.0074.150.000.000.000.0074.150.000.00(N/A)(N/A)0.000.00255.850.000.00(N/A)34.3435.2622.57296.60 188.01289.01PANEL E-201PANEL C-203PANEL A-205SPACESPACESPACESPACESPACESPACESPACESPACESPACEPANEL B-219PANEL B-221PANEL B-220PANEL F-222SPACESPACESPACESPACESPACESPACESPACE32 MERCHANT STREET, SUITE 208HONOLULU, HI 96813808-352-5299OWNER:HOMEWOOD SUITES by HILTON
SPOKANE VALLEY, WA
13515 E. Carlisle Avenue
Spokane Valley, WA 99216FSC PROJECT NO. 21012PERMITDOCUMENTSMay 31, 2024GL8 MirabeauPoint, LLCTMK:PID: 45101.0401 10909 E. Pierce LaneSpokane, WA 99206(509) 919-0901Revision ScheduleNumber Description Date5915 S REGAL STREETSUITE 201SPOKANE, WA 99223PH: 509.473.9218Kelly@kwrllc.comwww.kwrllc.com5/30/2024 1:27:38 PMSTATE OF WASHINGTONREGISTERED PROFESSIONAL ENG
INEER48350 KELLY A
N
DREW WATERMAN05.31.24PANEL SCHEDULESE-607(SEE NOTE 'a')(SEE NOTE 'a')(SEE NOTE 'a')(SEE NOTE 'a')
a.PANEL SCHEDULE SHOWN FOR BREAKER QUANTITIES AND PHASE / LOADBALANCING. SEE ALTERNATE CALCULATIONS ON SHEET E-603 FOR CALCULATEDLOAD BASED UPON NEC ALLOWABLE DEMAND FACTORS.a. PANEL SCHEDULE SHOWN FOR BREAKER QUANTITIES AND PHASE / LOADBALANCING. SEE ALTERNATE CALCULATIONS ON SHEET E-603 FOR CALCULATEDLOAD BASED UPON NEC ALLOWABLE DEMAND FACTORS.a. PANEL SCHEDULE SHOWN FOR BREAKER QUANTITIES AND PHASE / LOADBALANCING. SEE ALTERNATE CALCULATIONS ON SHEET E-603 FOR CALCULATEDLOAD BASED UPON NEC ALLOWABLE DEMAND FACTORS.a. PANEL SCHEDULE SHOWN FOR BREAKER QUANTITIES AND PHASE / LOADBALANCING. SEE ALTERNATE CALCULATIONS ON SHEET E-603 FOR CALCULATEDLOAD BASED UPON NEC ALLOWABLE DEMAND FACTORS.a. PROVIDE LOCKABLE CIRCUIT BREAKER.b. PROVIDE GFCI CIRCUIT BREAKER WITH 6mA TRIP.c. PROVIDE CIRCUIT BREAKER WITH RED HANDLE.aaccNEUTRAL:BUS AMPS:VOLTS:AIC:MAIN OCPD:LUGS:FED FROM:MOUNTING:LOCATION:CCTNO.NO.CCTCIRCUIT DESCRIPTIONCIRCUIT DESCRIPTIONPANEL:SEE ONE-LINE DIAGRAMENCLOSURE:KVA LOADBCCCTOCPDNOTESACCTOCPDNOTESL31SEE PLANSSURFACE208Y/120V 3P 4W10022,000MLOSTANDARD100%NEMA 12115/21.000.4520/134 |1.000.4520/16520/120/10.201.088720/10.300.3620/191020/10.201.0820/1121120/120/10.000.90141320/10.000.0020/1151620/10.000.0020/1181720/120/10.000.00201920/10.000.0020/1212220/10.000.0020/1242320/1-/10.000.002625-/10.000.00-/12728-/10.000.00-/13029-/1-/10.000.003231-/10.000.00-/13334-/10.000.00-/13635-/1-/10.000.003837-/10.000.00-/13940-/10.000.00-/14241-/1-/10.000.004443-/10.000.00-/14546-/10.000.00-/14847-/1-/10.000.005049-/10.000.00-/15152-/10.000.00-/15453-/1-/10.000.00TOTAL CALCULATED AMPSCONN. KVATOTAL KVA(50%>10)(100%)(125%)(125%)RECEPTACLESOTHER MOTORSLARGEST MOTORLIGHTINGCALC. KVAHEATINGCONTINUOUSNONCOIN/DIVERSEKITCHEN EQUIPNONCONTINUOUS(100%)(125%)(100%)TOTAL CONNECTED LOAD (KVA)NOTES:METERED DEMAND(125%)COOLINGABCTOTAL CONNECTED LOAD (AMPS)ABC7.02(100%)0.003.420.740.460.380.003.420.740.360.30COMPUTER19.957.192.000.000.200.000.002.000.000.200.000.00(N/A)(N/A)0.000.0019.490.000.00(N/A)2.112.732.1822.8518.1717.72BCU-2, FCU-331, FCU-332, FCU-333, FCU-334, FCU-335RECRECRECRECSPARESPARESPARESPARESPARESPARESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACEEH-31EH-32FIRE SMOKE DAMPERLTGDOOR MAG HOLDSPARESPARESPARESPARESPARESPARESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACENEUTRAL:BUS AMPS:VOLTS:AIC:MAIN OCPD:LUGS:FED FROM:MOUNTING:LOCATION:CCTNO.NO.CCTCIRCUIT DESCRIPTIONCIRCUIT DESCRIPTIONPANEL:SEE ONE-LINE DIAGRAMENCLOSURE:KVA LOADBCCCTOCPDNOTESACCTOCPDNOTESL32SEE PLANSSURFACE208Y/120V 3P 4W20022,000MLOSTANDARD100%NEMA 121125/25.8011.58100/234 |5.7712.57 |65100/2100/25.805.8087 |5.415.41 |910100/25.805.72100/21211 | |5.415.591413100/25.805.80100/21516 |5.415.77 |1817-/1-/10.000.002019-/10.000.00-/12122-/10.000.00-/12423-/1-/10.000.002625-/10.000.00-/12728-/10.000.00-/13029-/1-/10.000.00TOTAL CALCULATED AMPSCONN. KVATOTAL KVA(50%>10)(100%)(125%)(125%)RECEPTACLESOTHER MOTORSLARGEST MOTORLIGHTINGCALC. KVAHEATINGCONTINUOUSNONCOIN/DIVERSEKITCHEN EQUIPNONCONTINUOUS(100%)(125%)(100%)TOTAL CONNECTED LOAD (KVA)NOTES:METERED DEMAND(125%)COOLINGABCTOTAL CONNECTED LOAD (AMPS)ABC103.42(100%)0.0012.740.000.006.480.0015.480.000.005.18COMPUTER283.05101.970.000.0082.760.000.000.000.0082.760.000.00(N/A)(N/A)0.000.00287.060.000.00(N/A)39.7941.0322.59346.23 188.21336.06PANEL E-302PANEL B-304PANEL A-308PANEL F-310SPACESPACESPACESPACESPACESPACESPACEPANEL F-312PANEL B-314PANEL B-316PANEL B-318SPACESPACESPACESPACESPACESPACESPACENEUTRAL:BUS AMPS:VOLTS:AIC:MAIN OCPD:LUGS:FED FROM:MOUNTING:LOCATION:CCTNO.NO.CCTCIRCUIT DESCRIPTIONCIRCUIT DESCRIPTIONPANEL:SEE ONE-LINE DIAGRAMENCLOSURE:KVA LOADBCCCTOCPDNOTESACCTOCPDNOTESL33SEE PLANSSURFACE208Y/120V 3P 4W20022,000MLOSTANDARD100%NEMA 121125/25.8011.58100/234 |5.4113.50 |65100/2100/25.805.7287 |5.415.59 |910100/25.805.72100/21211 | |5.415.591413100/25.805.72100/21516 |5.775.59 |1817-/1-/10.000.002019-/10.000.00-/12122-/10.000.00-/12423-/1-/10.000.002625-/10.000.00-/12728-/10.000.00-/13029-/1-/10.000.00TOTAL CALCULATED AMPSCONN. KVATOTAL KVA(50%>10)(100%)(125%)(125%)RECEPTACLESOTHER MOTORSLARGEST MOTORLIGHTINGCALC. KVAHEATINGCONTINUOUSNONCOIN/DIVERSEKITCHEN EQUIPNONCONTINUOUS(100%)(125%)(100%)TOTAL CONNECTED LOAD (KVA)NOTES:METERED DEMAND(125%)COOLINGABCTOTAL CONNECTED LOAD (AMPS)ABC104.18(100%)0.0012.920.000.006.270.0015.840.000.005.01COMPUTER284.54102.510.000.0083.330.000.000.000.0083.330.000.00(N/A)(N/A)0.000.00289.170.000.00(N/A)39.8941.7822.51352.40 187.51336.85PANEL G-301PANEL A-303PANEL A-305PANEL A-307SPACESPACESPACESPACESPACESPACESPACEPANEL B-319PANEL B-321PANEL B-320PANEL F-322SPACESPACESPACESPACESPACESPACESPACENEUTRAL:BUS AMPS:VOLTS:AIC:MAIN OCPD:LUGS:FED FROM:MOUNTING:LOCATION:CCTNO.NO.CCTCIRCUIT DESCRIPTIONCIRCUIT DESCRIPTIONPANEL:SEE ONE-LINE DIAGRAMENCLOSURE:KVA LOADBCCCTOCPDNOTESACCTOCPDNOTESL34SEE PLANSSURFACE208Y/120V 3P 4W20010,000MLOSTANDARD100%NEMA 121100/25.725.80100/234 |5.595.41 |65100/2100/25.725.8087 |5.595.41 |910100/25.805.72100/21211 | |5.775.591413100/25.805.72100/21516 |5.415.59 |1817-/1-/10.000.002019-/10.000.00-/12122-/10.000.00-/12423-/1-/10.000.002625-/10.000.00-/12728-/10.000.00-/13029-/1-/10.000.00TOTAL CALCULATED AMPSCONN. KVATOTAL KVA(50%>10)(100%)(125%)(125%)RECEPTACLESOTHER MOTORSLARGEST MOTORLIGHTINGCALC. KVAHEATINGCONTINUOUSNONCOIN/DIVERSEKITCHEN EQUIPNONCONTINUOUS(100%)(125%)(100%)TOTAL CONNECTED LOAD (KVA)NOTES:METERED DEMAND(125%)COOLINGABCTOTAL CONNECTED LOAD (AMPS)ABC90.40(100%)0.0012.740.000.005.920.0015.480.000.004.74COMPUTER246.6188.840.000.0070.180.000.000.000.0070.180.000.00(N/A)(N/A)0.000.00250.930.000.00(N/A)34.0333.5022.87280.54 190.51284.88PANEL B-323PANEL B-325PANEL A-327PANEL A-329SPACESPACESPACESPACESPACESPACESPACEPANEL A-331PANEL A-333PANEL F-335PANEL B-337SPACESPACESPACESPACESPACESPACESPACENEUTRAL:BUS AMPS:VOLTS:AIC:MAIN OCPD:LUGS:FED FROM:MOUNTING:LOCATION:CCTNO.NO.CCTCIRCUIT DESCRIPTIONCIRCUIT DESCRIPTIONPANEL:SEE ONE-LINE DIAGRAMENCLOSURE:KVA LOADBCCCTOCPDNOTESACCTOCPDNOTESL35SEE PLANSSURFACE208Y/120V 3P 4W20010,000MLOSTANDARD100%NEMA 121100/25.725.80100/234 |5.595.77 |65100/2100/25.805.8087 |5.775.41 |910100/25.805.72100/21211 | |5.415.591413100/20.005.80-/11516 |0.005.41-/11817-/1-/10.000.002019-/10.000.00-/12122-/10.000.00-/12423-/1-/10.000.002625-/10.000.00-/12728-/10.000.00-/13029-/1-/10.000.00TOTAL CALCULATED AMPSCONN. KVATOTAL KVA(50%>10)(100%)(125%)(125%)RECEPTACLESOTHER MOTORSLARGEST MOTORLIGHTINGCALC. KVAHEATINGCONTINUOUSNONCOIN/DIVERSEKITCHEN EQUIPNONCONTINUOUS(100%)(125%)(100%)TOTAL CONNECTED LOAD (KVA)NOTES:METERED DEMAND(125%)COOLINGABCTOTAL CONNECTED LOAD (AMPS)ABC79.36(100%)0.0011.840.000.005.340.0013.680.000.004.27COMPUTER218.1478.590.000.0061.410.000.000.000.0061.410.000.00(N/A)(N/A)0.000.00220.280.000.00(N/A)28.4928.2822.59235.98 188.21237.76PANEL F-324PANEL B-326PANEL A-328PANEL B-330SPACESPACESPACESPACESPACESPACESPACEPANEL A-334PANEL F-336PANEL B-338SPACESPACESPACESPACESPACESPACESPACESPACESPACE32 MERCHANT STREET, SUITE 208HONOLULU, HI 96813808-352-5299OWNER:HOMEWOOD SUITES by HILTON
SPOKANE VALLEY, WA
13515 E. Carlisle Avenue
Spokane Valley, WA 99216FSC PROJECT NO. 21012PERMITDOCUMENTSMay 31, 2024GL8 MirabeauPoint, LLCTMK:PID: 45101.0401 10909 E. Pierce LaneSpokane, WA 99206(509) 919-0901Revision ScheduleNumber Description Date5915 S REGAL STREETSUITE 201SPOKANE, WA 99223PH: 509.473.9218Kelly@kwrllc.comwww.kwrllc.com5/30/2024 1:27:43 PMSTATE OF WASHINGTONREGISTERED PROFESSIONAL ENG
INEER48350 KELLY A
N
DREW WATERMAN05.31.24PANEL SCHEDULESE-608(SEE NOTE 'a')(SEE NOTE 'a')(SEE NOTE 'a')(SEE NOTE 'a')
a.PANEL SCHEDULE SHOWN FOR BREAKER QUANTITIES AND PHASE / LOADBALANCING. SEE ALTERNATE CALCULATIONS ON SHEET E-603 FOR CALCULATEDLOAD BASED UPON NEC ALLOWABLE DEMAND FACTORS.a. PANEL SCHEDULE SHOWN FOR BREAKER QUANTITIES AND PHASE / LOADBALANCING. SEE ALTERNATE CALCULATIONS ON SHEET E-603 FOR CALCULATEDLOAD BASED UPON NEC ALLOWABLE DEMAND FACTORS.a. PANEL SCHEDULE SHOWN FOR BREAKER QUANTITIES AND PHASE / LOADBALANCING. SEE ALTERNATE CALCULATIONS ON SHEET E-603 FOR CALCULATEDLOAD BASED UPON NEC ALLOWABLE DEMAND FACTORS.a. PANEL SCHEDULE SHOWN FOR BREAKER QUANTITIES AND PHASE / LOADBALANCING. SEE ALTERNATE CALCULATIONS ON SHEET E-603 FOR CALCULATEDLOAD BASED UPON NEC ALLOWABLE DEMAND FACTORS.a. PROVIDE LOCKABLE CIRCUIT BREAKER.b. PROVIDE GFCI CIRCUIT BREAKER WITH 6mA TRIP.c. PROVIDE CIRCUIT BREAKER WITH RED HANDLE.aacccNEUTRAL:BUS AMPS:VOLTS:AIC:MAIN OCPD:LUGS:FED FROM:MOUNTING:LOCATION:CCTNO.NO.CCTCIRCUIT DESCRIPTIONCIRCUIT DESCRIPTIONPANEL:SEE ONE-LINE DIAGRAMENCLOSURE:KVA LOADBCCCTOCPDNOTESACCTOCPDNOTESL42SEE PLANSSURFACE208Y/120V 3P 4W20022,000MLOSTANDARD100%NEMA 121125/25.8011.58100/234 |6.3212.57 |65100/2100/25.805.8087 |5.415.41 |910100/25.805.72100/21211 | |5.415.591413100/25.805.80100/21516 |5.415.77 |1817-/1-/10.000.002019-/10.000.00-/12122-/10.000.00-/12423-/1-/10.000.002625-/10.000.00-/12728-/10.000.00-/13029-/1-/10.000.00TOTAL CALCULATED AMPSCONN. KVATOTAL KVA(50%>10)(100%)(125%)(125%)RECEPTACLESOTHER MOTORSLARGEST MOTORLIGHTINGCALC. KVAHEATINGCONTINUOUSNONCOIN/DIVERSEKITCHEN EQUIPNONCONTINUOUS(100%)(125%)(100%)TOTAL CONNECTED LOAD (KVA)NOTES:METERED DEMAND(125%)COOLINGABCTOTAL CONNECTED LOAD (AMPS)ABC103.97(100%)0.0012.830.000.006.480.0015.660.000.005.18COMPUTER284.32102.430.000.0083.130.000.000.000.0083.130.000.00(N/A)(N/A)0.000.00288.580.000.00(N/A)39.7941.5822.59350.75 188.21336.06PANEL E-402PANEL B-404PANEL A-408PANEL F-410SPACESPACESPACESPACESPACESPACESPACEPANEL H-412PANEL B-414PANEL B-416PANEL B-418SPACESPACESPACESPACESPACESPACESPACENEUTRAL:BUS AMPS:VOLTS:AIC:MAIN OCPD:LUGS:FED FROM:MOUNTING:LOCATION:CCTNO.NO.CCTCIRCUIT DESCRIPTIONCIRCUIT DESCRIPTIONPANEL:SEE ONE-LINE DIAGRAMENCLOSURE:KVA LOADBCCCTOCPDNOTESACCTOCPDNOTESL43SEE PLANSSURFACE208Y/120V 3P 4W20022,000MLOSTANDARD100%NEMA 121125/25.8011.58100/234 |5.4112.57 |65100/2100/25.805.7287 |5.415.59 |910100/25.805.72100/21211 | |5.415.591413100/25.805.72100/21516 |5.775.59 |1817-/1-/10.000.002019-/10.000.00-/12122-/10.000.00-/12423-/1-/10.000.002625-/10.000.00-/12728-/10.000.00-/13029-/1-/10.000.00TOTAL CALCULATED AMPSCONN. KVATOTAL KVA(50%>10)(100%)(125%)(125%)RECEPTACLESOTHER MOTORSLARGEST MOTORLIGHTINGCALC. KVAHEATINGCONTINUOUSNONCOIN/DIVERSEKITCHEN EQUIPNONCONTINUOUS(100%)(125%)(100%)TOTAL CONNECTED LOAD (KVA)NOTES:METERED DEMAND(125%)COOLINGABCTOTAL CONNECTED LOAD (AMPS)ABC103.25(100%)0.0012.740.000.006.270.0015.480.000.005.01COMPUTER282.46101.760.000.0082.760.000.000.000.0082.760.000.00(N/A)(N/A)0.000.00286.590.000.00(N/A)39.8940.8522.51344.75 187.51336.85PANEL E-401PANEL A-403PANEL A-405PANEL A-407SPACESPACESPACESPACESPACESPACESPACEPANEL B-419PANEL B-420PANEL B-421PANEL F-422SPACESPACESPACESPACESPACESPACESPACENEUTRAL:BUS AMPS:VOLTS:AIC:MAIN OCPD:LUGS:FED FROM:MOUNTING:LOCATION:CCTNO.NO.CCTCIRCUIT DESCRIPTIONCIRCUIT DESCRIPTIONPANEL:SEE ONE-LINE DIAGRAMENCLOSURE:KVA LOADBCCCTOCPDNOTESACCTOCPDNOTESL44SEE PLANSSURFACE208Y/120V 3P 4W20010,000MLOSTANDARD100%NEMA 121100/25.725.80100/234 |5.595.41 |65100/2100/25.725.8087 |5.595.41 |910100/25.805.72100/21211 | |5.775.591413100/25.805.72100/21516 |5.415.59 |1817-/1-/10.000.002019-/10.000.00-/12122-/10.000.00-/12423-/1-/10.000.002625-/10.000.00-/12728-/10.000.00-/13029-/1-/10.000.00TOTAL CALCULATED AMPSCONN. KVATOTAL KVA(50%>10)(100%)(125%)(125%)RECEPTACLESOTHER MOTORSLARGEST MOTORLIGHTINGCALC. KVAHEATINGCONTINUOUSNONCOIN/DIVERSEKITCHEN EQUIPNONCONTINUOUS(100%)(125%)(100%)TOTAL CONNECTED LOAD (KVA)NOTES:METERED DEMAND(125%)COOLINGABCTOTAL CONNECTED LOAD (AMPS)ABC90.40(100%)0.0012.740.000.005.920.0015.480.000.004.74COMPUTER246.6188.840.000.0070.180.000.000.000.0070.180.000.00(N/A)(N/A)0.000.00250.930.000.00(N/A)34.0333.5022.87280.54 190.51284.88PANEL B-423PANEL B-425PANEL A-427PANEL A-429SPACESPACESPACESPACESPACESPACESPACEPANEL A-431PANEL A-433PANEL F-435PANEL B-437SPACESPACESPACESPACESPACESPACESPACENEUTRAL:BUS AMPS:VOLTS:AIC:MAIN OCPD:LUGS:FED FROM:MOUNTING:LOCATION:CCTNO.NO.CCTCIRCUIT DESCRIPTIONCIRCUIT DESCRIPTIONPANEL:SEE ONE-LINE DIAGRAMENCLOSURE:KVA LOADBCCCTOCPDNOTESACCTOCPDNOTESL45SEE PLANSSURFACE208Y/120V 3P 4W20010,000MLOSTANDARD100%NEMA 121100/25.725.80100/234 |5.595.77 |65100/2100/25.805.8087 |5.775.41 |910100/25.805.72100/21211 | |5.765.591413100/20.005.80-/11516 |0.005.41-/11817-/1-/10.000.002019-/10.000.00-/12122-/10.000.00-/12423-/1-/10.000.002625-/10.000.00-/12728-/10.000.00-/13029-/1-/10.000.00TOTAL CALCULATED AMPSCONN. KVATOTAL KVA(50%>10)(100%)(125%)(125%)RECEPTACLESOTHER MOTORSLARGEST MOTORLIGHTINGCALC. KVAHEATINGCONTINUOUSNONCOIN/DIVERSEKITCHEN EQUIPNONCONTINUOUS(100%)(125%)(100%)TOTAL CONNECTED LOAD (KVA)NOTES:METERED DEMAND(125%)COOLINGABCTOTAL CONNECTED LOAD (AMPS)ABC79.71(100%)0.0011.930.000.005.340.0013.860.000.004.27COMPUTER218.8678.850.000.0061.580.000.000.000.0061.580.000.00(N/A)(N/A)0.000.00221.260.000.00(N/A)28.4928.2822.94235.98 191.13237.76PANEL F-424PANEL B-426PANEL A-428PANEL B-430SPACESPACESPACESPACESPACESPACESPACEPANEL A-434PANEL F-436PANEL D-438SPACESPACESPACESPACESPACESPACESPACESPACESPACENEUTRAL:BUS AMPS:VOLTS:AIC:MAIN OCPD:LUGS:FED FROM:MOUNTING:LOCATION:CCTNO.NO.CCTCIRCUIT DESCRIPTIONCIRCUIT DESCRIPTIONPANEL:SEE ONE-LINE DIAGRAMENCLOSURE:KVA LOADBCCCTOCPDNOTESACCTOCPDNOTESL41SEE PLANSSURFACE208Y/120V 3P 4W10022,000MLOSTANDARD100%NEMA 12115/21.000.2920/134 |1.000.2920/16520/120/10.201.088720/10.300.3620/191020/10.201.0820/1121120/120/10.200.90141320/10.000.0020/1151620/10.000.0020/1181720/120/10.000.00201920/10.000.0020/1212220/10.000.0020/1242320/120/10.000.002625-/10.000.00-/12728-/10.000.00-/13029-/1-/10.000.003231-/10.000.00-/13334-/10.000.00-/13635-/1-/10.000.003837-/10.000.00-/13940-/10.000.00-/14241-/1-/10.000.004443-/10.000.00-/14546-/10.000.00-/14847-/1-/10.000.005049-/10.000.00-/15152-/10.000.00-/15453-/1-/10.000.00TOTAL CALCULATED AMPSCONN. KVATOTAL KVA(50%>10)(100%)(125%)(125%)RECEPTACLESOTHER MOTORSLARGEST MOTORLIGHTINGCALC. KVAHEATINGCONTINUOUSNONCOIN/DIVERSEKITCHEN EQUIPNONCONTINUOUS(100%)(125%)(100%)TOTAL CONNECTED LOAD (KVA)NOTES:METERED DEMAND(125%)COOLINGABCTOTAL CONNECTED LOAD (AMPS)ABC6.89(100%)0.003.420.410.460.380.003.420.410.360.30COMPUTER19.607.062.000.000.400.000.002.000.000.400.000.00(N/A)(N/A)0.000.0019.140.000.00(N/A)1.952.572.3821.4319.8316.28FCU-341, FCU-342, FCU-343, FCU-344, FCU-345RECRECRECRECSPARESPARESPARESPARESPARESPARESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACEEH-41EH-42FIRE SMOKE DAMPERLTGDOOR MAG HOLDFIRE ALARM CONTROL PANELSPARESPARESPARESPARESPARESPARESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACE32 MERCHANT STREET, SUITE 208HONOLULU, HI 96813808-352-5299OWNER:HOMEWOOD SUITES by HILTON
SPOKANE VALLEY, WA
13515 E. Carlisle Avenue
Spokane Valley, WA 99216FSC PROJECT NO. 21012PERMITDOCUMENTSMay 31, 2024GL8 MirabeauPoint, LLCTMK:PID: 45101.0401 10909 E. Pierce LaneSpokane, WA 99206(509) 919-0901Revision ScheduleNumber Description Date5915 S REGAL STREETSUITE 201SPOKANE, WA 99223PH: 509.473.9218Kelly@kwrllc.comwww.kwrllc.com5/30/2024 1:27:48 PMSTATE OF WASHINGTONREGISTERED PROFESSIONAL ENG
INEER48350 KELLY A
N
DREW WATERMAN05.31.24PANEL SCHEDULESE-609(SEE NOTE 'a')(SEE NOTE 'a')(SEE NOTE 'a')(SEE NOTE 'a')
a.PANEL SCHEDULE SHOWN FOR BREAKER QUANTITIES AND PHASE / LOADBALANCING. SEE ALTERNATE CALCULATIONS ON SHEET E-603 FOR CALCULATEDLOAD BASED UPON NEC ALLOWABLE DEMAND FACTORS.a. PANEL SCHEDULE SHOWN FOR BREAKER QUANTITIES AND PHASE / LOADBALANCING. SEE ALTERNATE CALCULATIONS ON SHEET E-603 FOR CALCULATEDLOAD BASED UPON NEC ALLOWABLE DEMAND FACTORS.a. PANEL SCHEDULE SHOWN FOR BREAKER QUANTITIES AND PHASE / LOADBALANCING. SEE ALTERNATE CALCULATIONS ON SHEET E-603 FOR CALCULATEDLOAD BASED UPON NEC ALLOWABLE DEMAND FACTORS.a. PANEL SCHEDULE SHOWN FOR BREAKER QUANTITIES AND PHASE / LOADBALANCING. SEE ALTERNATE CALCULATIONS ON SHEET E-603 FOR CALCULATEDLOAD BASED UPON NEC ALLOWABLE DEMAND FACTORS.a. PROVIDE LOCKABLE CIRCUIT BREAKER.b. PROVIDE GFCI CIRCUIT BREAKER WITH 6mA TRIP.c. PROVIDE CIRCUIT BREAKER WITH RED HANDLE.aaccNEUTRAL:BUS AMPS:VOLTS:AIC:MAIN OCPD:LUGS:FED FROM:MOUNTING:LOCATION:CCTNO.NO.CCTCIRCUIT DESCRIPTIONCIRCUIT DESCRIPTIONPANEL:SEE ONE-LINE DIAGRAMENCLOSURE:KVA LOADBCCCTOCPDNOTESACCTOCPDNOTESL51SEE PLANSSURFACE208Y/120V 3P 4W10022,000MLOSTANDARD100%NEMA 12115/21.000.5920/134 |1.000.5920/16525/320/10.201.3287 |0.721.3220/1910 |1.081.3220/1121125/320/10.361.321413 |0.901.3220/11516 |0.901.3220/1181715/220/10.500.792019 |0.300.7920/1212220/10.200.0020/1242320/120/10.000.00262520/10.000.0020/1272820/10.000.0020/1302920/120/10.000.00323120/10.000.0020/13334-/10.000.0020/13635-/1-/10.000.003837-/10.000.00-/13940-/10.000.00-/14241-/1-/10.000.004443-/10.000.00-/14546-/10.000.00-/14847-/1-/10.000.005049-/10.000.00-/15152-/10.000.00-/15453-/1-/10.000.00TOTAL CALCULATED AMPSCONN. KVATOTAL KVA(50%>10)(100%)(125%)(125%)RECEPTACLESOTHER MOTORSLARGEST MOTORLIGHTINGCALC. KVAHEATINGCONTINUOUSNONCOIN/DIVERSEKITCHEN EQUIPNONCONTINUOUS(100%)(125%)(100%)TOTAL CONNECTED LOAD (KVA)NOTES:METERED DEMAND(125%)COOLINGABCTOTAL CONNECTED LOAD (AMPS)ABC17.84(100%)0.003.966.924.951.000.003.966.923.960.80COMPUTER52.8219.032.000.000.200.000.002.000.000.200.000.00(N/A)(N/A)0.000.0049.520.000.00(N/A)6.946.414.4953.4637.6157.81FCU-351, FCU-352, FCU-353, FCU-354, FCU-355, FCU-500CU-04CU-05KE-7.2SPARESPARESPARESPARESPARESPARESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACEEH-51EH-52FIRE SMOKE DAMPERRECRECRECRECRECBUILDING SIGNAGELTGDOOR MAG HOLDSPARESPARESPARESPARESPARESPARESPACESPACESPACESPACESPACESPACESPACESPACESPACESPACENEUTRAL:BUS AMPS:VOLTS:AIC:MAIN OCPD:LUGS:FED FROM:MOUNTING:LOCATION:CCTNO.NO.CCTCIRCUIT DESCRIPTIONCIRCUIT DESCRIPTIONPANEL:SEE ONE-LINE DIAGRAMENCLOSURE:KVA LOADBCCCTOCPDNOTESACCTOCPDNOTESL52SEE PLANSSURFACE208Y/120V 3P 4W20022,000MLOSTANDARD100%NEMA 121125/25.8011.58100/234 |5.7712.57 |65100/2100/25.805.8087 |5.415.41 |910100/25.805.72100/21211 | |5.415.591413100/25.805.80100/21516 |5.415.77 |1817-/1-/10.000.002019-/10.000.00-/12122-/10.000.00-/12423-/1-/10.000.002625-/10.000.00-/12728-/10.000.00-/13029-/1-/10.000.00TOTAL CALCULATED AMPSCONN. KVATOTAL KVA(50%>10)(100%)(125%)(125%)RECEPTACLESOTHER MOTORSLARGEST MOTORLIGHTINGCALC. KVAHEATINGCONTINUOUSNONCOIN/DIVERSEKITCHEN EQUIPNONCONTINUOUS(100%)(125%)(100%)TOTAL CONNECTED LOAD (KVA)NOTES:METERED DEMAND(125%)COOLINGABCTOTAL CONNECTED LOAD (AMPS)ABC103.42(100%)0.0012.740.000.006.480.0015.480.000.005.18COMPUTER283.05101.970.000.0082.760.000.000.000.0082.760.000.00(N/A)(N/A)0.000.00287.060.000.00(N/A)39.7941.0322.59346.23 188.21336.06PANEL E-502PANEL B-504PANEL A-508PANEL F-510SPACESPACESPACESPACESPACESPACESPACEPANEL F-512PANEL B-514PANEL B-516PANEL B-518SPACESPACESPACESPACESPACESPACESPACENEUTRAL:BUS AMPS:VOLTS:AIC:MAIN OCPD:LUGS:FED FROM:MOUNTING:LOCATION:CCTNO.NO.CCTCIRCUIT DESCRIPTIONCIRCUIT DESCRIPTIONPANEL:SEE ONE-LINE DIAGRAMENCLOSURE:KVA LOADBCCCTOCPDNOTESACCTOCPDNOTESL53SEE PLANSSURFACE208Y/120V 3P 4W20022,000MLOSTANDARD100%NEMA 121125/25.8011.58100/234 |5.4112.57 |65100/2100/25.805.8087 |5.415.76 |910100/25.805.72100/21211 | |5.415.591413100/25.805.72100/21516 |5.775.59 |1817-/1-/10.000.002019-/10.000.00-/12122-/10.000.00-/12423-/1-/10.000.002625-/10.000.00-/12728-/10.000.00-/13029-/1-/10.000.00TOTAL CALCULATED AMPSCONN. KVATOTAL KVA(50%>10)(100%)(125%)(125%)RECEPTACLESOTHER MOTORSLARGEST MOTORLIGHTINGCALC. KVAHEATINGCONTINUOUSNONCOIN/DIVERSEKITCHEN EQUIPNONCONTINUOUS(100%)(125%)(100%)TOTAL CONNECTED LOAD (KVA)NOTES:METERED DEMAND(125%)COOLINGABCTOTAL CONNECTED LOAD (AMPS)ABC103.50(100%)0.0012.740.000.006.370.0015.480.000.005.10COMPUTER283.23102.040.000.0082.930.000.000.000.0082.930.000.00(N/A)(N/A)0.000.00287.300.000.00(N/A)40.0640.8522.59344.75 188.21338.25PANEL E-501PANEL D-503PANEL A-505PANEL A-507SPACESPACESPACESPACESPACESPACESPACEPANEL B-519PANEL B-520PANEL B-521PANEL F-522SPACESPACESPACESPACESPACESPACESPACENEUTRAL:BUS AMPS:VOLTS:AIC:MAIN OCPD:LUGS:FED FROM:MOUNTING:LOCATION:CCTNO.NO.CCTCIRCUIT DESCRIPTIONCIRCUIT DESCRIPTIONPANEL:SEE ONE-LINE DIAGRAMENCLOSURE:KVA LOADBCCCTOCPDNOTESACCTOCPDNOTESL54SEE PLANSSURFACE208Y/120V 3P 4W20010,000MLOSTANDARD100%NEMA 121100/25.725.80100/234 |5.595.41 |65100/2100/25.725.8087 |5.595.41 |910100/25.805.72100/21211 | |5.775.591413100/25.805.72100/21516 |5.415.59 |1817-/1-/10.000.002019-/10.000.00-/12122-/10.000.00-/12423-/1-/10.000.002625-/10.000.00-/12728-/10.000.00-/13029-/1-/10.000.00TOTAL CALCULATED AMPSCONN. KVATOTAL KVA(50%>10)(100%)(125%)(125%)RECEPTACLESOTHER MOTORSLARGEST MOTORLIGHTINGCALC. KVAHEATINGCONTINUOUSNONCOIN/DIVERSEKITCHEN EQUIPNONCONTINUOUS(100%)(125%)(100%)TOTAL CONNECTED LOAD (KVA)NOTES:METERED DEMAND(125%)COOLINGABCTOTAL CONNECTED LOAD (AMPS)ABC90.40(100%)0.0012.740.000.005.920.0015.480.000.004.74COMPUTER246.6188.840.000.0070.180.000.000.000.0070.180.000.00(N/A)(N/A)0.000.00250.930.000.00(N/A)34.0333.5022.87280.54 190.51284.88PANEL B-523PANEL B-525PANEL A-527PANEL A-529SPACESPACESPACESPACESPACESPACESPACEPANEL A-531PANEL A-533PANEL F-535PANEL B-537SPACESPACESPACESPACESPACESPACESPACENEUTRAL:BUS AMPS:VOLTS:AIC:MAIN OCPD:LUGS:FED FROM:MOUNTING:LOCATION:CCTNO.NO.CCTCIRCUIT DESCRIPTIONCIRCUIT DESCRIPTIONPANEL:SEE ONE-LINE DIAGRAMENCLOSURE:KVA LOADBCCCTOCPDNOTESACCTOCPDNOTESL55SEE PLANSSURFACE208Y/120V 3P 4W20010,000MLOSTANDARD100%NEMA 121100/25.725.80100/234 |5.595.77 |65100/2100/25.805.8087 |5.775.41 |910100/25.805.72100/21211 | |5.415.591413100/20.005.80-/11516 |0.005.41-/11817-/1-/10.000.002019-/10.000.00-/12122-/10.000.00-/12423-/1-/10.000.002625-/10.000.00-/12728-/10.000.00-/13029-/1-/10.000.00TOTAL CALCULATED AMPSCONN. KVATOTAL KVA(50%>10)(100%)(125%)(125%)RECEPTACLESOTHER MOTORSLARGEST MOTORLIGHTINGCALC. KVAHEATINGCONTINUOUSNONCOIN/DIVERSEKITCHEN EQUIPNONCONTINUOUS(100%)(125%)(100%)TOTAL CONNECTED LOAD (KVA)NOTES:METERED DEMAND(125%)COOLINGABCTOTAL CONNECTED LOAD (AMPS)ABC79.36(100%)0.0011.840.000.005.340.0013.680.000.004.27COMPUTER218.1478.590.000.0061.410.000.000.000.0061.410.000.00(N/A)(N/A)0.000.00220.280.000.00(N/A)28.4928.2822.59235.98 188.21237.76PANEL F-524PANEL B-526PANEL A-528PANEL B-530SPACESPACESPACESPACESPACESPACESPACEPANEL A-534PANEL F-536PANEL B-538SPACESPACESPACESPACESPACESPACESPACESPACESPACE32 MERCHANT STREET, SUITE 208HONOLULU, HI 96813808-352-5299OWNER:HOMEWOOD SUITES by HILTON
SPOKANE VALLEY, WA
13515 E. Carlisle Avenue
Spokane Valley, WA 99216FSC PROJECT NO. 21012PERMITDOCUMENTSMay 31, 2024GL8 MirabeauPoint, LLCTMK:PID: 45101.0401 10909 E. Pierce LaneSpokane, WA 99206(509) 919-0901Revision ScheduleNumber Description Date5915 S REGAL STREETSUITE 201SPOKANE, WA 99223PH: 509.473.9218Kelly@kwrllc.comwww.kwrllc.com5/30/2024 1:27:53 PMSTATE OF WASHINGTONREGISTERED PROFESSIONAL ENG
INEER48350 KELLY A
N
DREW WATERMAN05.31.24PANEL SCHEDULESE-610(SEE NOTE 'a')(SEE NOTE 'a')(SEE NOTE 'a')(SEE NOTE 'a')
a.PROVIDE LOCKABLE CIRCUIT BREAKER.b. PROVIDE AFCI CIRCUIT BREAKER.c. PROVIDE COMBINATION AFCI / GFCI CIRCUIT BREAKER WITH 6mA TRIP.d. PROVIDE GFCI CIRCUIT BREAKER WITH 6mA TRIP.e. PANEL SCHEDULE SHOWN FOR BREAKER QUANTITIES AND PHASE / LOAD BALANCING. SEEALTERNATE CALCULATIONS FOR CALCULATED LOAD BASED UPON NEC ALLOWABLEDEMAND FACTORS.a,ccccbbbcccbbbcccbbbcccbbbcccbbbcccbbba,ca,ca. PROVIDE LOCKABLE CIRCUIT BREAKER.b. PROVIDE AFCI CIRCUIT BREAKER.c. PROVIDE COMBINATION AFCI / GFCI CIRCUIT BREAKER WITH 6mA TRIP.d. PROVIDE GFCI CIRCUIT BREAKER WITH 6mA TRIP.e. PANEL SCHEDULE SHOWN FOR BREAKER QUANTITIES AND PHASE / LOAD BALANCING. SEEALTERNATE CALCULATIONS FOR CALCULATED LOAD BASED UPON NEC ALLOWABLEDEMAND FACTORS.a. PROVIDE LOCKABLE CIRCUIT BREAKER.b. PROVIDE AFCI CIRCUIT BREAKER.c. PROVIDE COMBINATION AFCI / GFCI CIRCUIT BREAKER WITH 6mA TRIP.d. PROVIDE GFCI CIRCUIT BREAKER WITH 6mA TRIP.e. PANEL SCHEDULE SHOWN FOR BREAKER QUANTITIES AND PHASE / LOAD BALANCING. SEEALTERNATE CALCULATIONS FOR CALCULATED LOAD BASED UPON NEC ALLOWABLEDEMAND FACTORS.a. PROVIDE LOCKABLE CIRCUIT BREAKER.b. PROVIDE AFCI CIRCUIT BREAKER.c. PROVIDE COMBINATION AFCI / GFCI CIRCUIT BREAKER WITH 6mA TRIP.d. PROVIDE GFCI CIRCUIT BREAKER WITH 6mA TRIP.e. PANEL SCHEDULE SHOWN FOR BREAKER QUANTITIES AND PHASE / LOAD BALANCING. SEEALTERNATE CALCULATIONS FOR CALCULATED LOAD BASED UPON NEC ALLOWABLEDEMAND FACTORS.a. PROVIDE LOCKABLE CIRCUIT BREAKER.b. PROVIDE AFCI CIRCUIT BREAKER.c. PROVIDE COMBINATION AFCI / GFCI CIRCUIT BREAKER WITH 6mA TRIP.d. PROVIDE GFCI CIRCUIT BREAKER WITH 6mA TRIP.e. PANEL SCHEDULE SHOWN FOR BREAKER QUANTITIES AND PHASE / LOAD BALANCING. SEEALTERNATE CALCULATIONS FOR CALCULATED LOAD BASED UPON NEC ALLOWABLEDEMAND FACTORS.a. PROVIDE LOCKABLE CIRCUIT BREAKER.b. PROVIDE AFCI CIRCUIT BREAKER.c. PROVIDE COMBINATION AFCI / GFCI CIRCUIT BREAKER WITH 6mA TRIP.d. PROVIDE GFCI CIRCUIT BREAKER WITH 6mA TRIP.e. PANEL SCHEDULE SHOWN FOR BREAKER QUANTITIES AND PHASE / LOAD BALANCING. SEEALTERNATE CALCULATIONS FOR CALCULATED LOAD BASED UPON NEC ALLOWABLEDEMAND FACTORS.aaaaaaCIRCUIT DESCRIPTIONCIRCUIT DESCRIPTIONCCTOCPDNO.CCTNEUTRAL:BUS AMPS:VOLTS:AIC:MAIN OCPD:LUGS:FED FROM:MOUNTING:CCTNO.PANEL:SEE ONE-LINE DIAGRAMLOCATION:ENCLOSURE:NOTESKVA LOADABCCTOCPDNOTESHSTANDARDMLO22,000100208/120V 2P 3WFLUSHSEE PLANS100%NEMA 10.981.4720/120/221431.001.4720/1 |0.361.5020/120/265871.101.5020/1 |0.360.8620/120/110912111.080.1720/120/10.000.00-/1-/1141316150.000.00-/1-/10.000.00-/1-/1181720190.000.00-/1-/10.000.00-/1-/1222124230.000.00-/1-/1BALANCED PHASE AMPSCONN. KVATOTAL KVA(50%>10)(100%)(125%)(125%)RECEPTACLESOTHER MOTORSLARGEST MOTORLIGHTINGCALC. KVAHEATINGCONTINUOUSNONCOIN/DIVERSEKITCHEN EQUIPNONCONTINUOUS(100%)(125%)(100%)TOTAL CONN. LOAD (KVA)NOTES:ABTOTAL CONN. LOAD (AMPS)ABMETERED DEMAND11.85(100%)0.002.340.000.000.460.002.340.000.000.36COMPUTER57.4011.940.000.009.140.000.000.000.009.140.000.00(N/A)(N/A)0.000.0056.975.536.3148.2654.50PTAC-01COOK-2GDHOODSPACESPACESPACESPACESPACESPACEDW, REFMWLTG, VANITY MIRRORMOTORIZED SHADES, RECRECRECSPACESPACESPACESPACESPACESPACECIRCUIT DESCRIPTIONCIRCUIT DESCRIPTIONCCTOCPDNO.CCTNEUTRAL:BUS AMPS:VOLTS:AIC:MAIN OCPD:LUGS:FED FROM:MOUNTING:CCTNO.PANEL:SEE ONE-LINE DIAGRAMLOCATION:ENCLOSURE:NOTESKVA LOADABCCTOCPDNOTESFSTANDARDMLO22,000100208/120V 2P 3WFLUSHSEE PLANS100%NEMA 10.981.4720/120/221431.001.4720/1 |0.371.5020/120/265871.801.5020/1 |0.360.8620/120/110912110.000.18-/120/10.000.00-/1-/1141316150.000.00-/1-/10.000.00-/1-/1181720190.000.00-/1-/10.000.00-/1-/1222124230.000.00-/1-/1BALANCED PHASE AMPSCONN. KVATOTAL KVA(50%>10)(100%)(125%)(125%)RECEPTACLESOTHER MOTORSLARGEST MOTORLIGHTINGCALC. KVAHEATINGCONTINUOUSNONCOIN/DIVERSEKITCHEN EQUIPNONCONTINUOUS(100%)(125%)(100%)TOTAL CONN. LOAD (KVA)NOTES:ABTOTAL CONN. LOAD (AMPS)ABMETERED DEMAND11.49(100%)0.002.340.000.000.470.002.340.000.000.37COMPUTER55.6911.580.000.008.780.000.000.000.008.780.000.00(N/A)(N/A)0.000.0055.245.545.9548.3351.55PTAC-01COOK-2GDRECSPACESPACESPACESPACESPACESPACEDW, REFMW/HOODLTG, VANITY MIRRORRECRECSPACESPACESPACESPACESPACESPACESPACECIRCUIT DESCRIPTIONCIRCUIT DESCRIPTIONCCTOCPDNO.CCTNEUTRAL:BUS AMPS:VOLTS:AIC:MAIN OCPD:LUGS:FED FROM:MOUNTING:CCTNO.PANEL:SEE ONE-LINE DIAGRAMLOCATION:ENCLOSURE:NOTESKVA LOADABCCTOCPDNOTESDSTANDARDMLO22,000100208/120V 2P 3WFLUSHSEE PLANS100%NEMA 10.981.4720/120/221431.001.4720/1 |0.341.5020/120/265871.621.5020/1 |0.360.8620/120/110912110.000.17-/120/10.000.00-/1-/1141316150.000.00-/1-/10.000.00-/1-/1181720190.000.00-/1-/10.000.00-/1-/1222124230.000.00-/1-/1BALANCED PHASE AMPSCONN. KVATOTAL KVA(50%>10)(100%)(125%)(125%)RECEPTACLESOTHER MOTORSLARGEST MOTORLIGHTINGCALC. KVAHEATINGCONTINUOUSNONCOIN/DIVERSEKITCHEN EQUIPNONCONTINUOUS(100%)(125%)(100%)TOTAL CONN. LOAD (KVA)NOTES:ABTOTAL CONN. LOAD (AMPS)ABMETERED DEMAND11.26(100%)0.001.980.000.000.420.001.980.000.000.34COMPUTER54.5411.340.000.008.940.000.000.000.008.940.000.00(N/A)(N/A)0.000.0054.145.515.7548.0350.01PTAC-01COOK-2GDHOODSPACESPACESPACESPACESPACESPACEDW, REFMWLTG, VANITY MIRRORRECRECSPACESPACESPACESPACESPACESPACESPACECIRCUIT DESCRIPTIONCIRCUIT DESCRIPTIONCCTOCPDNO.CCTNEUTRAL:BUS AMPS:VOLTS:AIC:MAIN OCPD:LUGS:FED FROM:MOUNTING:CCTNO.PANEL:SEE ONE-LINE DIAGRAMLOCATION:ENCLOSURE:NOTESKVA LOADABCCTOCPDNOTESCSTANDARDMLO22,000100208/120V 2P 3WFLUSHSEE PLANS100%NEMA 10.981.4720/120/221431.001.4720/1 |0.311.5020/120/265871.621.5020/1 |0.360.8620/120/110912110.000.17-/120/10.000.00-/1-/1141316150.000.00-/1-/10.000.00-/1-/1181720190.000.00-/1-/10.000.00-/1-/1222124230.000.00-/1-/1BALANCED PHASE AMPSCONN. KVATOTAL KVA(50%>10)(100%)(125%)(125%)RECEPTACLESOTHER MOTORSLARGEST MOTORLIGHTINGCALC. KVAHEATINGCONTINUOUSNONCOIN/DIVERSEKITCHEN EQUIPNONCONTINUOUS(100%)(125%)(100%)TOTAL CONN. LOAD (KVA)NOTES:ABTOTAL CONN. LOAD (AMPS)ABMETERED DEMAND11.23(100%)0.001.980.000.000.380.001.980.000.000.31COMPUTER54.3611.310.000.008.940.000.000.000.008.940.000.00(N/A)(N/A)0.000.0053.995.485.7547.8050.01PTAC-01COOK-2GDHOODSPACESPACESPACESPACESPACESPACEDW, REFMWLTG, VANITY MIRRORRECRECSPACESPACESPACESPACESPACESPACESPACECIRCUIT DESCRIPTIONCIRCUIT DESCRIPTIONCCTOCPDNO.CCTNEUTRAL:BUS AMPS:VOLTS:AIC:MAIN OCPD:LUGS:FED FROM:MOUNTING:CCTNO.PANEL:SEE ONE-LINE DIAGRAMLOCATION:ENCLOSURE:NOTESKVA LOADABCCTOCPDNOTESBSTANDARDMLO22,000100208/120V 2P 3WFLUSHSEE PLANS100%NEMA 10.981.4720/120/221431.001.4720/1 |0.351.5020/120/265871.441.5020/1 |0.361.0420/120/110912110.000.00-/1-/10.000.00-/1-/1141316150.000.00-/1-/10.000.00-/1-/1181720190.000.00-/1-/10.000.00-/1-/1222124230.000.00-/1-/1BALANCED PHASE AMPSCONN. KVATOTAL KVA(50%>10)(100%)(125%)(125%)RECEPTACLESOTHER MOTORSLARGEST MOTORLIGHTINGCALC. KVAHEATINGCONTINUOUSNONCOIN/DIVERSEKITCHEN EQUIPNONCONTINUOUS(100%)(125%)(100%)TOTAL CONN. LOAD (KVA)NOTES:ABTOTAL CONN. LOAD (AMPS)ABMETERED DEMAND11.10(100%)0.001.980.000.000.430.001.980.000.000.35COMPUTER53.7911.190.000.008.780.000.000.000.008.780.000.00(N/A)(N/A)0.000.0053.375.705.4149.5447.24PTAC-01COOK-2GD, RECSPACESPACESPACESPACESPACESPACESPACEDW, REFMW/HOODLTG, VANITY MIRRORRECRECSPACESPACESPACESPACESPACESPACESPACECIRCUIT DESCRIPTIONCIRCUIT DESCRIPTIONCCTOCPDNO.CCTNEUTRAL:BUS AMPS:VOLTS:AIC:MAIN OCPD:LUGS:FED FROM:MOUNTING:CCTNO.PANEL:SEE ONE-LINE DIAGRAMLOCATION:ENCLOSURE:NOTESKVA LOADABCCTOCPDNOTESASTANDARDMLO22,000100208/120V 2P 3WFLUSHSEE PLANS100%NEMA 10.981.4720/120/221431.001.4720/1 |0.291.5020/120/265871.621.5020/1 |0.360.8620/120/110912110.000.00-/1-/10.000.00-/1-/1141316150.000.00-/1-/10.000.00-/1-/1181720190.000.00-/1-/10.000.00-/1-/1222124230.000.00-/1-/1BALANCED PHASE AMPSCONN. KVATOTAL KVA(50%>10)(100%)(125%)(125%)RECEPTACLESOTHER MOTORSLARGEST MOTORLIGHTINGCALC. KVAHEATINGCONTINUOUSNONCOIN/DIVERSEKITCHEN EQUIPNONCONTINUOUS(100%)(125%)(100%)TOTAL CONN. LOAD (KVA)NOTES:ABTOTAL CONN. LOAD (AMPS)ABMETERED DEMAND11.05(100%)0.001.980.000.000.370.001.980.000.000.29COMPUTER53.4711.120.000.008.780.000.000.000.008.780.000.00(N/A)(N/A)0.000.0053.125.465.5947.6848.67PTAC-01COOK-2GDSPACESPACESPACESPACESPACESPACESPACEDW, REFMW/HOODLTG, VANITY MIRRORRECRECSPACESPACESPACESPACESPACESPACESPACE32 MERCHANT STREET, SUITE 208HONOLULU, HI 96813808-352-5299OWNER:HOMEWOOD SUITES by HILTON
SPOKANE VALLEY, WA
13515 E. Carlisle Avenue
Spokane Valley, WA 99216FSC PROJECT NO. 21012PERMITDOCUMENTSMay 31, 2024GL8 MirabeauPoint, LLCTMK:PID: 45101.0401 10909 E. Pierce LaneSpokane, WA 99206(509) 919-0901Revision ScheduleNumber Description Date5915 S REGAL STREETSUITE 201SPOKANE, WA 99223PH: 509.473.9218Kelly@kwrllc.comwww.kwrllc.com5/30/2024 1:27:58 PMSTATE OF WASHINGTONREGISTERED PROFESSIONAL ENG
INEER48350 KELLY A
N
DREW WATERMAN05.31.24PANEL SCHEDULESE-611UNIT TYPE A (TYPICAL)(SEE NOTE 'e')UNIT TYPE B (TYPICAL)(SEE NOTE 'e')UNIT TYPE C (TYPICAL)(SEE NOTE 'e')UNIT TYPE H (TYPICAL)(SEE NOTE 'e')UNIT TYPE F (TYPICAL)(SEE NOTE 'e')UNIT TYPE D (TYPICAL)(SEE NOTE 'e')
acccbbbacccbbbcda,ccda. PROVIDE LOCKABLE CIRCUIT BREAKER.b. PROVIDE AFCI CIRCUIT BREAKER.c. PROVIDE COMBINATION AFCI / GFCI CIRCUIT BREAKER WITH 6mA TRIP.d. PROVIDE GFCI CIRCUIT BREAKER WITH 6mA TRIP.e. PANEL SCHEDULE SHOWN FOR BREAKER QUANTITIES AND PHASE / LOAD BALANCING. SEEALTERNATE CALCULATIONS FOR CALCULATED LOAD BASED UPON NEC ALLOWABLEDEMAND FACTORS.a. PROVIDE LOCKABLE CIRCUIT BREAKER.b. PROVIDE AFCI CIRCUIT BREAKER.c. PROVIDE COMBINATION AFCI / GFCI CIRCUIT BREAKER WITH 6mA TRIP.d. PROVIDE GFCI CIRCUIT BREAKER WITH 6mA TRIP.e. PANEL SCHEDULE SHOWN FOR BREAKER QUANTITIES AND PHASE / LOAD BALANCING. SEEALTERNATE CALCULATIONS FOR CALCULATED LOAD BASED UPON NEC ALLOWABLEDEMAND FACTORS.bCIRCUIT DESCRIPTIONCIRCUIT DESCRIPTIONCCTOCPDNO.CCTNEUTRAL:BUS AMPS:VOLTS:AIC:MAIN OCPD:LUGS:FED FROM:MOUNTING:CCTNO.PANEL:SEE ONE-LINE DIAGRAMLOCATION:ENCLOSURE:NOTESKVA LOADABCCTOCPDNOTESGSTANDARDMLO22,000125208/120V 2P 3WFLUSHSEE PLANS100%NEMA 10.981.4720/120/221431.001.4720/1 |0.433.1220/130/265871.123.1220/1 |0.360.8620/120/110912112.500.1730/220/12.501.47 |20/2141316151.201.4720/1 |0.001.44-/120/1181720190.000.00-/1-/10.000.00-/1-/1222124230.000.00-/1-/1BALANCED PHASE AMPSCONN. KVATOTAL KVA(50%>10)(100%)(125%)(125%)RECEPTACLESOTHER MOTORSLARGEST MOTORLIGHTINGCALC. KVAHEATINGCONTINUOUSNONCOIN/DIVERSEKITCHEN EQUIPNONCONTINUOUS(100%)(125%)(100%)TOTAL CONN. LOAD (KVA)NOTES:ABTOTAL CONN. LOAD (AMPS)ABMETERED DEMAND24.67(100%)0.002.520.000.000.540.002.520.000.000.43COMPUTER119.1224.780.000.0021.720.000.000.000.0021.720.000.00(N/A)(N/A)0.000.00118.6012.6312.04112.93 108.39PTAC-01COOK-4GDHOODPTAC-01RECSPACESPACESPACEDW, REFMWLTG, VANITY MIRRORMOTORIZED SHADES, RECRECDRYWASHSPACESPACESPACESPACECIRCUIT DESCRIPTIONCIRCUIT DESCRIPTIONCCTOCPDNO.CCTNEUTRAL:BUS AMPS:VOLTS:AIC:MAIN OCPD:LUGS:FED FROM:MOUNTING:CCTNO.PANEL:SEE ONE-LINE DIAGRAMLOCATION:ENCLOSURE:NOTESKVA LOADABCCTOCPDNOTESESTANDARDMLO22,000125208/120V 2P 3WFLUSHSEE PLANS100%NEMA 10.981.4720/120/221431.001.4720/1 |0.433.1220/130/265870.743.1220/1 |0.360.8620/120/110912112.501.4730/220/22.501.47 | |141316151.201.2620/120/10.000.00-/1-/1181720190.000.00-/1-/10.000.00-/1-/1222124230.000.00-/1-/1BALANCED PHASE AMPSCONN. KVATOTAL KVA(50%>10)(100%)(125%)(125%)RECEPTACLESOTHER MOTORSLARGEST MOTORLIGHTINGCALC. KVAHEATINGCONTINUOUSNONCOIN/DIVERSEKITCHEN EQUIPNONCONTINUOUS(100%)(125%)(100%)TOTAL CONN. LOAD (KVA)NOTES:ABTOTAL CONN. LOAD (AMPS)ABMETERED DEMAND23.94(100%)0.002.160.000.000.540.002.160.000.000.43COMPUTER115.6224.050.000.0021.350.000.000.000.0021.350.000.00(N/A)(N/A)0.000.00115.1011.1912.75101.85 113.90PTAC-01COOK-4GDPTAC-01RECSPACESPACESPACESPACEDW, REFMW/HOODLTG, VANITY MIRRORMOTORIZED SHADES, RECRECDRYWASHSPACESPACESPACESPACE32 MERCHANT STREET, SUITE 208HONOLULU, HI 96813808-352-5299OWNER:HOMEWOOD SUITES by HILTON
SPOKANE VALLEY, WA
13515 E. Carlisle Avenue
Spokane Valley, WA 99216FSC PROJECT NO. 21012PERMITDOCUMENTSMay 31, 2024GL8 MirabeauPoint, LLCTMK:PID: 45101.0401 10909 E. Pierce LaneSpokane, WA 99206(509) 919-0901Revision ScheduleNumber Description Date5915 S REGAL STREETSUITE 201SPOKANE, WA 99223PH: 509.473.9218Kelly@kwrllc.comwww.kwrllc.com5/30/2024 1:28:03 PMSTATE OF WASHINGTONREGISTERED PROFESSIONAL ENG
INEER48350 KELLY A
N
DREW WATERMAN05.31.24PANEL SCHEDULESE-612UNIT TYPE E (TYPICAL)UNIT TYPE G (TYPICAL)(SEE NOTE 'e')(SEE NOTE 'e')
CEILING SPACEFLOORCEILING SPACENYLON THROAT CONNECTORAND PLASTIC BUSHING (TYP).PULL CORDSTUB RACEWAY ABOVE ABOVEACCESSIBLE CEILING1" CONDUIT2-1/8" DEEP, 4" SQUARE OUTLET BOXWHEN DEVICE IS SHOWN ONMEZZANINE LEVEL, STUB RACEWAYINTO ACCESSIBLE CEILING SPACEBELOW, OR INTO NEAREST IDF ROOMPULL CORDEXTENSION 'MUD' RING, SIZEDTO ACCOMMODATE DEVICESSHOWN, WITH DEPTH ASREQUIRED FOR FLUSHINSTALLATION. MUD RING TOFINISH TO WALL SURFACESUCH THAT DEVICES CAN BEMOUNTED WITHOUT SHIMS.COORDINATE DEPTH OF ALLMUD RINGS WITH THE WALLFINISHES FOR WHICH THEYARE INSTALLED.STANDARD RADIUS CONDUITSWEEPGENERAL NOTES:1. ATTACH FIXTURE TO SUSPENDEDCEILING SYSTEM WITH 4 EARTHQUAKECLIPS.2. MC CABLE IS ALLOWED FORMANUFACTURED FIXTURE WHIPS.3. DETAIL IS TYPICAL FOR ALL RECESSEDFIXTURES IN SUSPENDED T-BARCEILING SYSTEMSHILTI CC27 CLIP OREQUAL (TYPICAL)STRUCTURENO. 10 SAFETY WIRES TIED TO SAFETY WIRESUPPORT HOLES, FASTEN TO BUILDINGSTRUCTURE, MINIMUM (4) WIRES PER LIGHTFIXTURE PLACED AT CORNERS. INSTALL SUCHTHAT FIXTURE DROPS NOT MORE THAN 6INCHES IN THE EVENT OF CEILING GRID FAILURE3-TWIST MINIMUMLUMINAIRE MANUFACTURER'SEARTHQUATE CLIP, (4) PERFIXTURE AT CORNERS, ATTACHEDWITH SHEET METAL SCREWFIXTURE WHIP FROMJUNCTION BOX(6-FOOT LONG MAX)LUMINAIRE PER SCHEDULET-BAR GRID (BY OTHERS)ACOUSTICAL CEILING TILE(TYPICAL)LUMINAIRE PERSCHEDULET-BAR CEILING GRID(BY OTHERS)SEAL WITH FIRE BARRIER (WHEREREQUIRED TO MAINTAIN FIRE RATINGOF FIRE-RATED PARTITIONS) AFTERCABLE INSTALLATION. FOR EMPTYCONDUITS PROVIDE REMOVABLE FIREBARRIER IN EACH END OF SLEEVE.DETAIL NOTES:1. THIS DETAIL SHOWS A WIRING / CABLING CHASE THROUGH A PARTITION ONLY. SOFFIT CHASESARE SIMILAR IN SUPPORT AND END FITTINGS. EXTEND BEYOND SOFFIT AREAS OR PASTDUCTWORK INTO ACCESSIBLE CEILING SPACES OR MEZZANINE SPACES.PLASTIC INSULATED PRESS-ONBUSHINGS ON EACHPULL CORDEMT CONDUIT SLEEVE: LENGTH ASREQUIRED TO EXTEND BEYONDNON-ACCESSIBLE CEILING OR DUCTWORKCONDUIT STRAP / SUPPORT TO WALL STUDPROVIDE CAULKING AROUND SLEEVE ATRATED ASSEMBLIES. PROVIDE FIRE CAULKSUSPENDED CEILINGNEUTRAL BUS#4 MAIN BONDING JUMPER(NEC 250.28)#6 BARE COPPER TO GROUND RODS(NEC 250.52.A.5)#2 BARE COPPER TO CONCRETEENCASED ELECTRODE(NEC 250.52.A.3)3/4" COPPER-CLAD GROUNDRODS (4 MINIMUM) AT CORNERPOINTS OF PAD, CONCEAL AFTERINSPECTIONGRADE#4 COPPER EQUIPMENT BONDINGJUMPER (NEC 250.92)EQUIPMENT GROUNDING BUS20'-0" MINNEW GENERATORNEWGENERATOR#4 BARE COPPER GROUNDRING (TYP.)3/4" COPPER-CLAD GROUNDRODS (4 MINIMUM) ATCORNER POINTS OF PAD,CONCEAL AFTER INSPECTION#4 BARE COPPER BONDEDTO EQUIPMENT (TYP.)PLAN VIEW GENERATOR GROUNDING ELECTRODE SYSTEMBOND TO BUILDING FOUNDATION STEELAND REBAR SUPPORT IN CMU WALLMINIMUM OF 20'-0" OF CONTINUOUSBARE COPPER CONDUCTORENCASED IN NOT LESS THAN 2" OFCONCRETE COVERNEUTRAL BUS#500 KCMIL MAINBONDING JUMPER(NEC 250.28)#2 BARE COPPER TO INTERSYSTEMBONDING TERMINATION(NEC 250.94)#4 BARE COPPER#3/0 BARE COPPER TOCONCRETE ENCASEDELECTRODE3/4" COPPER-CLAD GROUNDRODS (2 MINIMUM), CONCEALAFTER INSPECTIONGRADE#500 KCMIL COPPEREQUIPMENT BONDING JUMPER(NEC 250.92)EQUIPMENT GROUNDING BUS#3/0 BARE COPPER GROUNDING ELECTRODECONDUCTOR TO NEAREST ACCESSIBLE POINTOF INCOMING METAL WATER SERVICE PIPING,PROVIDE CLAMPS AS NECESSARY(NEC 250.104.A.1)#3/0 BARE COPPER GROUNDING ELECTRODECONDUCTOR TO INTERIOR METAL GASPIPING, PROVIDE CLAMPS AS NECESSARY(NEC 250.104.B)WATERMETERUNDERGROUND WATER PIPE20'-0" MINMAIN SERVICE#3/0 BARE COPPER GROUNDING ELECTRODECONDUCTOR TO EFFECTIVELY GROUNDEDMETAL FRAME OF BUILDING(NEC 250.52.A.2)METAL IN-GROUND SUPPORT STRUCTUREMINIMUM 20'-0" OF CONTINUOUS BARE COPPERCONDUCTOR ENCASED IN NOT LESS THAN 2" OFCONCRETE COVERNEUTRAL BUS#6 BARE COPPER#6 AWG BARE COPPERTO CONCRETEENCASED ELECTRODE3/4" COPPER-CLAD GROUNDRODS (2 MINIMUM), CONCEALAFTER INSPECTIONGRADE#6 AWG COPPER EQUIPMENTBONDING JUMPER(NEC 250.92)EQUIPMENT GROUNDING BUS20'-0" MINSITE STORAGEBUILDING#6 AWG BARE COPPER GROUNDINGELECTRODE CONDUCTOR TO EFFECTIVELYGROUNDED METAL FRAME OF BUILDING(NEC 250.52.A.2)METAL IN-GROUND SUPPORT STRUCTUREMINIMUM 20'-0" OF CONTINUOUS BARE COPPERCONDUCTOR ENCASED IN NOT LESS THAN 2" OFCONCRETE COVERDO NOT BOND GROUNDAND NEUTRAL BUSESEQUIPMENT GROUNDINGCONDUCTOR WITH FEEDERSIZED PER ONE-LINE DIAGRAM.32 MERCHANT STREET, SUITE 208HONOLULU, HI 96813808-352-5299NOTE: CONTRACTOR SHALL CHECK ANDVERIFY ALL DIMENSIONS AT JOB BEFOREPROCEEDING WITH WORK.OWNER:THIS WORK WAS PREPARED BY ME OR UNDERMY SUPERVISION AND CONSTRUCTION OF THISPROJECT WILL BE UNDER MY OBSERVATIONHOMEWOOD SUITES by HILTON
SPOKANE VALLEY, WA
13515 E. Carlisle Avenue
Spokane Valley, WA 99216FSC PROJECT NO. 21012PERMITDOCUMENTSMarch 31, 2024GL8 MirabeauPoint, LLCTMK:PID: 45101.0401 10909 E. Pierce LaneSpokane, WA 99206(509) 919-0901Revision ScheduleNumber Description Date5915 S REGAL STREETSUITE 201SPOKANE, WA 99223PH: 509.473.9218Kelly@kwrllc.comwww.kwrllc.comKELLY A
N
DREW WATERMANSTATE OF WASHINGTONREGISTERED PROFESSIONAL ENG
INEER48350 PRELIMINARY5/28/2024 5:04:06 PMELECTRICAL DETAILSE-701SCALE:1LUMINAIRE SEISMIC MOUNTING DETAILNTSSCALE:3TYPICAL DATA ROUGH-IN DETAILNTSSCALE:2CONDUIT SLEEVE DETAILNTSSCALE:5GENERATOR GROUNDING DETAILNTSSCALE:4MAIN SERVICE GROUNDING DETAILNTS
4" SQUARE BOX & COVER12" FROM CEILING (DIV 26)CFCI CONDUIT EMBEDDED INWALL 1/2" CONDUIT MIN. STUBINTO DOOR FRAME OR STOREFRONT STRUCTURE (DIV 26)CFCI RACEWAY & OFOICABLE FOR DOOR LOCKOFOI CABLE FOR DOORCONTACT SWITCH (DIV 08)OFOI CABLE FOR REQUESTTO EXIT DEVICE MOTIONDETECTOR VERIFY WITHOWNER SECURITY PROVIDEROFOI CABLE FOR CARD READER(TYPICAL)SECURE SIDE CARD READER W/COVER PLATE.46"ACCESS CONTROL READERSMOUNT @ 48" AFF* SEE DOOR HARDWARESCHEDULE FOR OTHERELECTRIC OR MAGNETICLOCKING DEVICESPROVIDED BY DIV 08.ACCESSIBLE CEILINGMAGNETIC DOOR CONTACT SWITCH (DIV08) EMBEDDED IN DOOR AND DOOR JAMCABLE(S) TO ACCESS DOORCONTROLLER AND SECURITYPANEL LOCATED IN MDF / ITROOM VIA RACEWAYELECTRIC STRIKEEMBEDDED IN DOOR JAMDOOR FRAMEFINISH FLOORFLOOR SLABELECTRIC STRIKE*DOOR FRAME3/4" CONDUIT (MIN.)TO CONTROL PANELSX1H1 X2 H2 X3 H3 X0NEUTRAL BUSSUPPLY SIDE BONDINGJUMPER PER NEC 250.66GROUND BUSDISTRIBUTION ORBRANCH PANELDRY-TYPE TRANSFORMERSEPARATELY DERIVED SYSTEMSEISMIC SPRING MOUNTWITH 1" DEFLECTION(TYPICAL OF 4)MAIN CIRCUITBREAKERFLEXIBLEMETALLICCONDUITGROUNDING ELECTRODE SYSTEM,BOND TO BUILDING STEEL(TYPICAL FOR SEPARATELY DERIVED SYSTEMS)EQUIPMENTGROUNDINGCONDUCTORHOUSEKEEPING PAD(REFER TO STRUCTURAL)480V FEEDER FROMUPSTREAM DISTRIBUTIONEQUIPMENTHOUSEKEEPING PAD(REFER TO STRUCTURAL)FINISHED FLOORSECONDARY CONDUCTORS: MUSTNOT EXCEED 25' PRIOR TOTERMINATING INTO OVERCURRENTDEVICE PER NEC 240.21(C)(6).PROVIDE DEDICATED 20A, 120V CIRCUIT BREAKER WITH RED, LOCKABLE HANDLE CAPABLE OF BEING LOCKED IN THE "ON" POSITION. SEE POWER AND FIRE ALARM SHEETS FOR PROPOSED NUMBER AND LOCATION OF ALL FIRE ALARM EQUIPMENT, DEVICES, ETC. EXACTQUANTITY AND LOCATIONS TO BE DETERMINED BY THE FIRE ALARM INSTALLER.SIZE CONDUIT AND WIRES IN ACCORDANCE WITH FIRE ALARM SYSTEM MANUFACTURER RECOMMENDATIONS AND SPECIFICATIONS.EXACT QUANTITY OF FLOW AND TAMPER SWITCHES TO BE DETERMINED BY SPRINKLER SUPPLIER. FIELD COORDINATE WITHSPRINKLER INSTALLER PRIOR TO BIDDING FOR QUANTITY AND LOCATION OF FLOW AND TAMPER SWITCHES.EXTERIOR DEVICES TO BE ON SEPARATE CIRCUIT.VISUAL NOTIFICATION AND SPEAKER / STROBE COMBINATION DEVICES. VERIFY CONDUIT AND CABLE TYPE/SIZE WITH SYSTEMINSTALLER.PROVIDE BATTERY BOX(ES) AS REQUIRED TO ENSURE A MINIMUM OF 24 HOURS OF OPERATION UPON LOSS OF NORMAL POWER.PROVIDE SBUS COMMUNICATIONS SINGLE-MODE FIBER OPTIC MODULES TO NETWORK REMOTE FIRE ALARM PANELS TO MASTERPANEL. PROVIDE SINGLE-MODE FIBER BETWEEN PANELS PER MANUFACTURER'S INSTRUCTIONS. NEW ADDRESSABLE FIRE ALARMCONTROL PANELSLC #1SHSLC #2SHSUPERVISORY INPUTTSFS4NAC CIRCUITSPRINKLERALARM BELLDIGITAL ALARM COMMUNICATORTRANSMITTER (DACT)CONNECT TO TELEPHONEBACKBOARD. PROVIDE 4-PAIRTELEPHONE CABLE.BATTERYPOWERSUPPLY120VAC POWER CONNECTION,SEE PLANS FOR CIRCUITING.1WPWPWPBNAC CIRCUITDETAIL FLAG NOTES:1234567J723333TO NEXT ADDRESSABLEINITIATING DEVICETO NEXT ADDRESSABLEINITIATING DEVICETO NEXT STROBEOR EOLRTO NEXT STROBEOR EOLRNETWORK INTERFACE CARD5BACKUP CELLULAR DIALERRZVOLTAGE MONITORING FOR FIREALARM SYSTEM INTERFACERELAYS FOR FLOOR RECALL ANDFIREMAN'S SERVICE.COORDINATE QUANTITY WITHELEVATOR INSTALLERDETECTOR OUTPUT SIGNALS TOELEVATOR CONTROL MODULEPROVISIONS FOR FUTURE INTERFACEWITH TYPE 1 KITCHEN HOOD8 NEW ADDRESSABLE FIRE ALARMSLAVE PANELSLC #1SHSLC #2SHBATTERYPOWERSUPPLY7233TO NEXT ADDRESSABLEINITIATING DEVICETO NEXT ADDRESSABLEINITIATING DEVICE8120VAC POWER CONNECTION,SEE PLANS FOR CIRCUITING.1J8NAC CIRCUITWPWPWPNAC CIRCUIT33TO NEXT STROBEOR EOLRTO NEXT STROBEOR EOLR5TO BUILDING LOCAL AREA NETWORK32 MERCHANT STREET, SUITE 208HONOLULU, HI 96813808-352-5299OWNER:HOMEWOOD SUITES by HILTON
SPOKANE VALLEY, WA
13515 E. Carlisle Avenue
Spokane Valley, WA 99216FSC PROJECT NO. 21012PERMITDOCUMENTSMay 31, 2024GL8 MirabeauPoint, LLCTMK:PID: 45101.0401 10909 E. Pierce LaneSpokane, WA 99206(509) 919-0901Revision ScheduleNumber Description Date5915 S REGAL STREETSUITE 201SPOKANE, WA 99223PH: 509.473.9218Kelly@kwrllc.comwww.kwrllc.com5/30/2024 12:48:48 PMSTATE OF WASHINGTONREGISTERED PROFESSIONAL ENG
INEER48350 KELLY A
N
DREW WATERMAN05.31.24ELECTRICAL DETAILSE-702SCALE:1ACCESS DOOR ROUGH-IN DETAILNTSSCALE:2DRY-TYPE TRANSFORMER DETAILNTSSCALE:3FIRE ALARM RISER DIAGRAMNTS