2006, 05-26 Bldg D: Temporary C of O and backup docs SGkne ...•••v Valley 11707 E.Sprague Ave. • Suite 106 • Spokane Valley,WA 99206 (509) 921-1000 • Fax(509)921-1008 • cityhall @spokanevalley.org TEMPORARY CERTIFICATE OF OCCUPANCY May 26, 2006 Donald E Neraas 104 S Freya Street Spokane WA 99202 RE: 601 S Woodruff, Bldg D (2-B) Woodruff Apartments Permit 405-0080 This Temporary Certificate of Occupancy is being issued according to the 2003 IBC Code 110.3 which states: The building official is authorized to issue a temporary certificate of occupancy before the completion of the entire work covered by the permit, provided that such portion or portions shall be occupied safely. The building official shall set a time period during which the temporary certificate of occupancy is valid. The following items must be complete before issue of Certificate of Occupancy: Building Department: • Not applicable Planning Department: • Not applicable Public Works/Engineering Department: • Engineer to submit letter certifying swales built and constructed per plan prior to final Certificate of Occupancy. Fire: • Not applicable This document does not authorize the holder or their designated agent to violate any provisions of the code or any other ordinance of this jurisdiction. Life safety for the occupants will be maintained at all times, any unsafe acts or failure to provide minimum code requirements will result in the revocation of the Temporary Occupancy. This Temporary Certificate of Occupancy is valid until June 30, 2006, 5:00 p.m. in where this Temporary Certificate will become null and void if the conditions listed have not been instituted and the Certificate of Occupancy has not been obtained. Jodk ain / Permit Specialist/CO Coordinator Mf- Y--30--06 TUE F72 :39 PM NERARC. fiRCHITECT 509 534 8481 P. 01 DON4ILD E. ,NERE1 AS, MA - mciacr• Ar e,rica17 Institute ofAnthitec s 30 May 2006 "TO: Torn Scholtens, Building Official, City of Spokane Valley RE: Rudeen Development LLC - "Woodruff-108" Apartments 10009 E. .7th Avenue, Spokane Valley, WA SUB]: Project Completion Inspection/Evaluation In the above project, the following buildings are entirely complete: "1•-A", "1-8", "1-C", "2-A", "2-C", "TWA", "3-B"„ and the recreation building. Building "2-B" is now fully complete in every regard. Very truly, DONALD E. NEF&AAS Architect TAN°OFFICE.GCN TE • YELLOW FLAG OUILD 4t3 423o3• 104 SC31PTfd FPFVA CTgecT . c.rinv FINAL CERTIFICATE OF OCCUPANCY SIGN OFFS TEMPORARY CERTIFICATE OF OCCUPANY SIGN OFFS ADDRESS: (c)(31 5 CA7 C) 1 - PERMIT NO: 0 5 -©c C, 7)1 - Abbreviated Use: IR - Code: T G Conditions: INSPECTOR/DATE: 53 a ,q# Z 6 PLANNING/DATE: (c) _ �{ k (1fkt ENGINEERING/DATE: ( A , , si l.4. FIRE/DATE: (1\ HEALTH/DATE: MULTI FAMILY/EHB 1848: Page 1 of 1 Jodi Main From: Alysa Wiyrick Sent: Thursday, April 27, 2006 9:48 AM To: Jodi Main; Torn Scholtens Cc: John Hohman; Henry Allen Subject: 601 S Woodruff Temporary CofO Jodi, Public Works is okay with a temporary CofO for 601 S Woodruff for Buildings F, C, D, and E, Prior to final CofO, the applicant needs to provide a letter from the design engineer stating the swales are constructed according to plan. If you have any questions, please let me know. Alysa Wiyrick Assistant Development Engineer City of Spokane Valley 11707 E. Sprague Ave Ste. 106 Spokane Valley, WA 99206 (509) 688-0228 (509)921-1008 Fax awiyrick(spokanevalley.orq (Contents of this email and any reply are subject to public disclosure.) 4/27/2006 Page 1 of 1 Jodi Main From: Chase, Paul [ChaseP @SpokaneValleyFire.comj Sent: Thursday, April 20, 2006 1:18 PM To: Jodi Main Cc: Loftin, Norm; Andersen, Patricia Subject: C of 0 for 601 S Woodruff Jodi Re 601 S.Woodruff- Pheasant Ridge 1. I witnessed the alarm and fire sprinkler acceptance tests on buildings C, D, E, F today 04-20-06. 2. ****Buildings D and E still need siding and a building sign before they are ready to occupy. Your inspector can watch for that.**** 3. I have copies of all the alarm acceptance tests...If you need copies I can make a complete set. 4. I am waiting for copies of fire sprinklers acceptance tests from Patriot for a couple of buildings. We have witnessed all the building tests and we can get you copies of the entire set A-F if you desire...I expect them to fax it to me today. I will be out of the office Friday and Monday... Paul Chase Spokane Valley Fire Department 10319 E. Sprague Ave. Spokane, WA 99206-3627 Phone (509)892-4121 Fax (509)892-4127 ChaseP(r SpokaneValleyFire.com "Fire Sprinklers Save Lives" 4/20/2006 • • • EIRE ALARM SYSTEM r�a r'Yl • RECORD OF COMPLETION hy, ,Name of protected property: f/+ -. • , C/ Address: , / D a. - r Representative of protected property(name/phone): ' V y' `' ._ • Authority having jurisdiction: . `�G. s r_ !'�s Address/telephone number: / S c4% .� I'} i 1.72 OrganixsLian name/phone Representative name f phano Installer KE ,Srlr/ i.s r,J.e,f`t./SDI-S��Y-s"l�4 �us�i u�yf/sy9-Ps 5'/ Supplier 04/..?e .S'y.r f - r t-,../ce,Tl/fo 4 ,-s—se-/- 01.6r re/4/r't //S9Y- pS V/ • Service organization —gyre~#S GI—* e ,/r49 ~.5"3 y- S"/ Peel($:.1/.1'��s`f',f0°„,sy Location ofre oord(as-built)drawings:. A/-S'i Lcationoroporaiion and maintenance manuals: cat/ S/tee • • Location of test reports: CJ.ti s-fY e_ . A contract for test and inspection in accordance with NFPA standard(s) • Contract No(s): Effective date: Expiration date: • System Software �y • (a)Operating system(executive)software r+evisio level(s): /y (b)Site-specific software revision date: x'7/9/O • (c)Revision completed by: _ f . .• _ C 49, - (name) •- (firm 1.Type(s)of System or Service "lC NFPA 72,Chapter 6--Local If alarm is transomed to locatian(a)off premises,list received: • ./9 4/ ft1 ( d� Zoe,. : Sao-?s•. =ay 94 FV a 574 - ____NPPA72,.Ohapterfi—Remote Station • Telephone numbers of the organization receiving alarm: . Alarm: • • Supervisory: Trouble: • If alarms are retransmitted to public fire service communications centers or others,indicate location and telephone . numbers of the organization receiving alarm: • • Indicate how alarm is retransmitted: • • • - NFPA72,Chapter 8-Proprietary Telephone numbers of the organization receiving alarm: Alarm: • • Supervisory: Trouble: If alarms are retransmitted to public fire service communications centers otothers,indicate location and telephone • numbers of the organization receiving alarm: . . • Indicate how alarm is retransmitted: ' NFPA 72,Chapter 8---Central Station Prime contractor:• • Central station location: • (NFPA 72,1 of 4) . • ' Copyright NFPA . • ° I • • • Means of transmission of signals from the protected premises to the central station: . McCulloli • Multiplex .• •- •• One-way radio •• x- .Digital alarm communicator .Two-way radio Others . • • Means of transmission of alarms to the public fire service communications center. . . (a) PJJJM ' ' a t'e.- 5ysteisl-- - .• . System location: i G: Sa-e/c)/I • - _NFPA 72,Chapter 97 Auxiliary . • • Indicate type of connection: Local energy Shunt Parallel telephone . • Location of telephone number for receipt of signals:: - - 2.Record of System Installation. . . . . • • . - ' . • (loll out after installation is complete.and wiring-is checked for opens,shorts,ground faults,and improper branching,. • . but prior to conducting operational acceptance teats,) • - . . . . This system has been installed is accordance with the NA stands s a shown below,was inspected by • • • -Fi'RF .S�?Jfe#V7$ /t1# 6 on, r ,/C ,includes the devices shown . .in 5'and 6,and has been in service since .••'y//1/1-0 6 • • .�NFPA 72,Chapters(12 3 4 6'() 7 8 9 10 .1 (circle all that apply) • - . • X NFPA 70,National Eleetrieal Code,Article 760 )c Manufacturer's ins iructsons . Other(s, � . �/ �. • ' • Signed: .4`La�i//1 �.-'< ..... .2 - . - . Date: • // !© • . ;Organization: • iE'G t3 ��PyL 4f /t/elf . - • • • • 3.Record of System Operation Docunieatation in accordance with Inspection Testing Form,Figure 10.62.3,is attached f. ' AR operational features and-functions of this system were tested by PS Al "date - y/llfece . and found to be operating properly in accordance with the requirements of•. . . • • ' • ' • .NPPA72,.Chapters 1 2 S 4 6 0 7 •8 9 10 (circlo all that apply) x NFPA,70,National Electrical Code,Article 760 . • - - Manufacturer's instructions - . • ' . - ,__..Other(speci ): - uu . • Signed: Date: %%•%/� • . Organization: 4/710s-,-6;* L✓.D - - • - 4.Signaling Line Circuits . - -Quantity and class of signaling line circuits connected to system(see NFPA72,- 1e C&I): • . •Quantity: ta Style: y Class: 0 V (NFPA 72,2 Q14) • • Copyright NFPA . . • 5.Alarm Initiating Devices and Circuits. ° Quantity and class of initiating device circuits(see NFPA 72,7hb1e 6.5): Quantity: Style:- • Class: • • ° MANUAL . (a)Manual stations' Noncoded _ Transmitters Coded Addressable • - (b)Combination manual fire alarm and guard's tour coded stations_ • • • AUTOMATIC y • • Coverage: Complete Partial /� • . •Selective • - Nonrequiiud . • • (a)Smote detectors • Ion . Photo Addressable. • - (b)Duct detectors - Ion Photo Addressable (a)Heat detectors FT. RR F`i'/RR — RC Addressable 6 ., . (d)Sprinkler waterflow indicators:Transmitters - Nonoodod Coded Addressable+- • (e)The alarm verification•foatme is disabled }C or enabled ,changed from -secends•to seconds, . (A Other(list): . • • 6.Supervisory Signal-Initiating Devices and Circuits(use blanks to indicate quantity of devices) • • GUARD'S TOUR. . ' (a) Coded stations . • • ' . - • ''4 •(b) . Noncoded stations ' - (c) > Compulsory guard's tour system-comprised of - transmitter stations and intermediate stations ' Note:Ceiubination devices are recorded under e(b);Manual,and 6(a),Guard's Tour ' . SPRINKLER SYSTEM- . ' •. - -• . _ Check if provided ' (a),_,Valve supervisory switches ' (b) Bulling temperature points . (c) • Site water'temperatuxe points . . • • : (d) °• Site water supply level points • Electric fre pump: • . : - . ' • (e) Fire pump power . . - ' . (0 Firs pump'inning . . ' . (g) Phase reversal Engine-driven fire pump:- ' •• iW Selector in auto position . , _ • : • . (0 Engine or control panel trouble : • . • () Firs pump running • ENGINE-DRIVEN GENERATOR.: • • ____ (a) Selector hn auto positron •- . • (b) Control panel trouble ' ' . . • • , • • ' (c)" Transfer switches ' • . ' (d) • Engin e running • - • Others rvi ryfuncgon(s)(wiry): Z,Yl ' Go /j di2/ / G JP tr- yQ ell C V /��%affC re 4('`l� .r . (NFP1i72,3of4). • Copyright NFP A . • • • 7.Artnunoiator(s) ,,� Number:�/ Typo: 'CF ivcatlon C� s eA-1 o(P¢n 4/11C2 8.Alarm Notification Appliances and Circuits NFPA 72,Chapter 6.9 Emergency Voice/Alarm Service Quantity ofvoice/alamiclhannels:_ Single:. _ Multiple: Quantity of speakers installed: Quantity of speaker zones: Q uantity of telephones or telephone jacks included in system: • Quantity and the class of notification appliance circuits connected to system(see NFPA 72,Table e.7): Quantity: C2 Style: _ -. Class: • Types and quantities of notification appliances installed: • (a)Bells, With Visible - - (b)Speakers_ - WithVioible (c) Horns P.e. With Visrlale� (d)Chimes With Visible -. • • . : (e) Other. - WithVialbie (0 Visible appliances without audrlble:_ - 9.System Power Supplies (a)Fire Alarm Control Panel: Nominal volta e: /s V4 C . Current rating: . l S—Art l P Overcurrentprotection: Type: J. " A• ! Current rating / Location: Rec.- ,VGc•IY /" /"Vr6 .8.'S 1,1 /frt. (b) Secondary(standby): • Storage battery: e2 _ . Amp-hour rating; 7 414 Calculated capacity to drive system,in hours: 07 Engine-driven generator dedicated to fire alarm system: Location of fuel storage: - (c) Emergency system used as backup to primary power supply: Emergency system described in NFPA 70,Article 700: • 10.Comments Frequency of routine tests and inspections,if other than in accordance with the referenced NFPA standard(s): System deviations from the referenced NFPA standard(s)ar e: • (signe•, + marls • (tae) (date) ( 9(V.401fr alarm ervfce co. p. (tile) (date) (signed)for central.ration (title) (dale) • Upon completion ofthe system(s)satisfactory test(s)witnessed(if required by the authority having jurisdiction): t. )representative of e authority haying jurisdiction (tile) (date) (NFPA 72,4 of 4) Copyright NFPA • FROM PATRIOT FIE RE PROTECTION, INC. (THU) APR 20 2006 14 :02/ST. 14 :00/No. 6834436680 P 12 ` 1 .� ' PREPR.0 GTION . CONTRACTORS MATERIAL & TEST REPoRT FOR UNDERGROUND PIPING PROCEDURE Upon coMpletion bl work.Impaction end testa shell be mode by Ma contractors representative and wllneeaed by an owner's representative_All de'OM shell be dorendled Ind aystem 1.11 In service before oonfraalor"a personnel ifnelly leave the Iab. A certificate shall be filled out and signed by both repre tentetivoa.Copia&anal be property]for approving au Monti ea,owners,and geMraetIN.It Is undarelood the OWSlsr'I paten a Mat lve'a signature In ho way prajudlOaa any claim apalrlst contractor for foully material,poor workmanship,or Ashur,to comply with app loving authority's requirement'or look'erdlnorCee, PROPERTY NAME 1 1 DATE Y P'.PEFiTY ADDRESS r J r< ACCEPTED BY APPROVING AUTHORITIES(" ' . PLANS IN TAU.ATION CONFORMS TO ACCEPTED PLANS YES NO EQUIPMENT USED IS APPROVED YES NO IF NO,I XPLAN DEVIATIONS - -:ri N IN --e E e '• I'MENT BEEN INSTRU TED • OCATION YES N OP CONTHQ'L VALVE AND CARE AND MAINTENANCE OF THIS NEW EQUIPMENT? IF NO,EXPLAIN ' • IHS7Ti1JCTIQM$ . • HAVE COPIES OF THE APPROPRIATE INSTRUCTIONS AND CARE AND MAINTENANCE CHARTS UYES Mr—) SEEN LEFT ON PREMISES? • IF NO,EXPLAIN LOCATION 'T PL! ILDINGS I .... .m.....PIPE TY ES D CLASS IP N M d�a,r�•+s»a;�S • `'MD PI ' ■ NO • FITTINGS CONFORM TO ,4./;,''"- STANDARD tI YES ❑NO UNDUl'ROUNO IF NO,EVPU1N PIPES `l`.'/ . AND Jt]INI JOINTS NEEDING ANCHORAGE CLAMP i TRAPPED,OR BLOCKED IN ■YES III NO ACCORDANCE WITH ti} STANDARD . IF NO EXPLAIN 'P . 7..........■...—..,– ....L.. .......` 'iieo--rf J� FLUSHING Flow the required rale until water Ie oltiL,bl f4tltCbled by no caltdplion of foreign m■larlel In buriap baps Si OUflale Sigh KS hydrant*and blow. r ,r 7] -" t�L' olfs,Ffueh at flows not leas than 300 GPM for4lnOT plpe,tilC 15A(�+`7ftfLivhply�,T 8OQPM for ti.inch pipe,2444 GPM tor tO Inch plpe,and 35200 Phi for 12dnch f7 I r _ pipe,When supply cannot produce atlpuleied flow raise,obtain'elltdrlldfri'Kiallabis. TEST HYDROSTATIC Hydrostatic test shell he made at not twill than 200 pal for two howre of 50 Pal oboe italic preaaure In excess Of 154 pal lot two hovid. � CI�I T LEAKAGE thew pipe laid with rubber paskirled Jolrils shall,It the workmanship 14 eels leclory.have Ilttle or no leakage et the joints,The amount er leakage at the Jolnte shall not oxcsed 2 eta.per hour per 100 joints Irreepecttve Of pipe diameter,The leakage eta be distributed over all lolnla.If such leakage occurs Si a low Joints the Installation shell be considered uneatlafactory end naceaaary repairs made.The amount ci anOW4ble leakage specified above may be Inc raasb by I fl.oz per In.valve diameter par hour for each metal sealed valve isolating the teat elation.If dry barrel hydrants are listed with the mein valve open,c0 the hydrants are under pressure,an additional 5 oz per minute leakage Its permitted for each hydrant. NEW UNDERGROUND PIPING FLUSHED ACCORDING TO STANDARD .YES r NO R i3 7 w[/ BY(COMPANY) 1i'Vv�, IF NO, EXPLAIN FLU IN WAS OBTAINED-- THROUGH WHAT TYPE OF Of ENl G FLUSHING ' pPUDLIC WATER ❑TANK OR RESERVOIR 1:1 FIRE PUMP 1 HYDRANT BUTT ja OPEN FIFE TESTS LEAD-INS FLUSHED ACC•'DING TO •TANDAAO ■YE' ■NO BY(COMPANY) IF NO,EXPLAIN HOW FLUSHING FLOW WAS OBTAINED THROUGH WHAT TYPE CIF OPENING ❑PUBLIC WATER ❑TANK OR RESERVOIR 0 FIRE PUMP in Y CONN.TO FLANGE&SPIGOT 0 OPEN PIPE 853 (OVER) FROM PATRIOT FIRE PROTECTION, INC. (THU)APR 20 2006 14 :02/ST, 14 :00/No. 6834436680 P 13 ALL NEW UNDERGROUND PIPING HYD-4 TATI • LY TESTED AT Ja INT- .r• 1 D HYDReSTATIC 10- PSI FOR HOURS DYES yl;SNO TEST TOTAL T AMOUNT OF E ME A tI RED LEAKAGE GALS. - . HOURS TEST ALL ABLE LEAKA E — — �� GALS. HOURS ' HYDRANTS t.i- '• -11X' i I t�.1' •1 •• -T . r•. . •- • ❑YES ❑NO WATER •NT^414 VALVES LEFT WIDE OPEN .. LSYES • LI NO CONThOL IF NO,STATE REASON VALVES T DEF MENT CONNECTIONS AND HYDRANTS 1NTERCHANG WTTH THOSE OF FIRE DEPARTMENT ANSWERING ALARM ❑YES ❑NO • • d- I SERVICE CONTRACTOR SE• ft(t O / R . (D l.TE T ' FATHIFP0A9CF . . SSWITNESSED BY S1ONATURES FOR PROPERTY er"ER('1c N •) TITLE DATE 11 iii_1!/[1,� l.{ *- rslN di) 1 'l i1e mg •WY T I - 1FY •• TH INFO- TION HEREIN IS TRU AND THAT `E SP' NKLI;;R SY 1 T W • INSTALLED IN ACCORD- ANCE WITH RCW 18.100 AND THE RULES ADOPTED BY THE WASHINGTON ADMIM$T Tive CODE AS ADMINISTERED BY CFEETIFICATION THE STATE 11 MAAS1.AL • �,,,,�y�, c i ITrJ.J �4�`" k, thAME Cf•i ' / HOLM MOLT OR TY1111 a - :•, U•. Of O I ATE Of CO�Arl7ENCYH�� CERTIFICATE REGISTRATION i• .yam 1:,. "‘ . DATE ( (LPL. . .7 "1 16G RAcK •• Vkzt'zmikargii...46_ 0? . . . Page 1 of 1 Jodi Main From: Micki Harnois Sent: Friday, May 26, 2006 9:11 AM To: Jodi Main Cc: Doug Powell; Tom Scholtens; Greg McCormick Subject: RE: TCO FOR 601 S WOODRUFF, BLDG-D Planning Division approves the TCO for this project. Micki Original Message From: Jodi Main Sent: Friday, May 26, 2006 9:02 AM To: Micki Harnois Subject: TCO FOR 601 S WOODRUFF, BLDG-D They are wanting at TCO for Bldg 0, Pheasant Ridge Appts. Thanks :) Jodi Main Permit Specialist City of Spokane Valley Building Dept Phone: 509-688-0203 Fax: 509-688-0037 5/26/2006